MIB Viewer

EKINOPS-Pm1004VDC-MIB

656 objects
MIB for managing Ekinops modules with PM1004vdc software
OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.38IdentitymodulePm1004vdcMIB for managing Ekinops modules with PM1004vdc software
1.3.6.1.4.1.20044.38.2Nodepm1004vdcalarms
1.3.6.1.4.1.20044.38.2.1Nodepm1004vdcAlmOther
1.3.6.1.4.1.20044.38.2.1.1Nodepm1004vdcAlmOtherNurg
1.3.6.1.4.1.20044.38.2.1.1.2Nodepm1004vdcAlmsynthAlm2
1.3.6.1.4.1.20044.38.2.1.1.2.1Scalarpm1004vdcAlmConfTableSaveread-onlycurrentPM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> other…
1.3.6.1.4.1.20044.38.2.1.1.2.2Scalarpm1004vdcAlmInvUploadread-onlycurrentInventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> other (1) <Alarmtype> other (1) <Polarit…
1.3.6.1.4.1.20044.38.2.1.1.2.3Scalarpm1004vdcAlmConfTableLoadread-onlycurrentPM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> other (1) <Alarmt…
1.3.6.1.4.1.20044.38.2.1.1.2.4Scalarpm1004vdcAlmCorrelatOffread-onlycurrentNot Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> other (1) <Alarmtype> other (1) <Pol…
1.3.6.1.4.1.20044.38.2.1.1.2.5Scalarpm1004vdcAlmMaintenanceOnread-onlycurrentMaintenance Mode :This OID indicates that the PM is in maintenance mode. <Help> This alarm indicates that the maintenance mode is enabled on the PM <Condtype> …
1.3.6.1.4.1.20044.38.2.1.2Nodepm1004vdcAlmOtherUrg
1.3.6.1.4.1.20044.38.2.1.2.194Nodepm1004vdcAlmmodInitFailLevel2
1.3.6.1.4.1.20044.38.2.1.2.194.1Scalarpm1004vdcAlmLedFailread-onlycurrentLed Fail :This OID indicates that Led register has not been correctly initalized <Help> This alarm indicates if the module LEDs are correctly initialized <Cond…
1.3.6.1.4.1.20044.38.2.1.2.194.2Scalarpm1004vdcAlmNextColdBootForcedread-onlycurrentNext Cold Boot Forced :This OID indicates that the next Reset will be forced Cold <Help> This alarm indicates that the next reset of the module will be forced …
1.3.6.1.4.1.20044.38.2.1.2.194.3Scalarpm1004vdcAlmBootUndoneread-onlycurrentBoot Undone :This OID indicates that the boot has not been correctly achieved <Help> This alarm indicates if the module has correctly boot <Condtype> BOOT_UNDO…
1.3.6.1.4.1.20044.38.2.1.2.194.4Scalarpm1004vdcAlmResetHwInitFailread-onlycurrentReset HW Init Fail :This OID indicates that the HW intialization has caused unknown intial conditions <Help> This alarm indicates if the HW has been correctly …
1.3.6.1.4.1.20044.38.2.1.2.194.5Scalarpm1004vdcAlmSwInitFailread-onlycurrentSW Init Fail :This OID indicates that the SW intialization has caused unknown intial conditions <Help> This alarm indicates if the SW module is correctly initi…
1.3.6.1.4.1.20044.38.2.1.2.195Nodepm1004vdcAlmmodInitFailLevel3
1.3.6.1.4.1.20044.38.2.1.2.195.1Scalarpm1004vdcAlmGwIdentFailread-onlycurrentGW Ident Fail :This OID indicates that GW identification has not been read <Help> This alarm indicates if the GW has been correctly identified <Condtype> GW_ID…
1.3.6.1.4.1.20044.38.2.1.2.195.2Scalarpm1004vdcAlmObmTypeReadFailread-onlycurrentOBM Type Read Fail :This OID indicates that OBM type has not been recognized <Help> This alarm indicates if the OBM board has been correctly identified <Condty…
1.3.6.1.4.1.20044.38.2.1.2.195.3Scalarpm1004vdcAlmInitModuleFailread-onlycurrentInit Module Fail :This OID indicates that the Module has not been correctly initialized <Help> This alarm indicates if the SW module is correctly initialized <…
1.3.6.1.4.1.20044.38.2.1.2.195.5Scalarpm1004vdcAlmXfp1InitFailread-onlycurrentXFP1 Init Fail :This OID indicates that the XFP has not been correctly initialized <Help> This alarm indicates if the line transceiver 1 is correctly initializ…
1.3.6.1.4.1.20044.38.2.1.2.195.6Scalarpm1004vdcAlmXfp2InitFailread-onlycurrentXFP2 Init Fail :This OID indicates that the XFP has not been correctly initialized <Help> This alarm indicates if the line transceiver 2 is correctly initializ…
1.3.6.1.4.1.20044.38.2.1.2.195.7Scalarpm1004vdcAlmLine1InitFailread-onlycurrentLine1 Init Fail :This OID indicates that the Line registersvsubset has not been correctly initialized <Help> This alarm indicates if the line port 1 is correct…
1.3.6.1.4.1.20044.38.2.1.2.195.8Scalarpm1004vdcAlmLine2InitFailread-onlycurrentLine2 Init Fail :This OID indicates that the Line register subset has not been correctly initialized <Help> This alarm indicates if the line port 2 is correctl…
1.3.6.1.4.1.20044.38.2.1.2.195.9Scalarpm1004vdcAlmClient1InitFailread-onlycurrentClient1 Init Fail :This OID indicates that Client 1 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 1 is cor…
1.3.6.1.4.1.20044.38.2.1.2.195.10Scalarpm1004vdcAlmClient2InitFailread-onlycurrentClient2 Init Fail :This OID indicates that Client 2 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 2 is cor…
1.3.6.1.4.1.20044.38.2.1.2.195.11Scalarpm1004vdcAlmClient3InitFailread-onlycurrentClient3 Init Fail :This OID indicates that Client 3 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 3 is cor…
1.3.6.1.4.1.20044.38.2.1.2.195.12Scalarpm1004vdcAlmClient4InitFailread-onlycurrentClient4 Init Fail :This OID indicates that Client 4 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 4 is cor…
1.3.6.1.4.1.20044.38.2.1.2.195.13Scalarpm1004vdcAlmClient5InitFailread-onlycurrentClient5 Init Fail :This OID indicates that Client 5 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 5 is cor…
1.3.6.1.4.1.20044.38.2.1.2.195.14Scalarpm1004vdcAlmClient6InitFailread-onlycurrentClient6 Init Fail :This OID indicates that Client 6 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 6 is cor…
1.3.6.1.4.1.20044.38.2.1.2.198Nodepm1004vdcAlmclientRxProt
1.3.6.1.4.1.20044.38.2.1.2.198.1Scalarpm1004vdcAlmAdddropClient1Westread-onlycurrentClient West Rx Side Active :This OID indicates the Client is active on West receiving side <Condtype> ADDDROP_CLIENT1_WEST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.38.2.1.2.198.2Scalarpm1004vdcAlmAdddropClient2Westread-onlycurrentClient West Rx Side Active :This OID indicates the Client is active on West receiving side <Condtype> ADDDROP_CLIENT2_WEST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.38.2.1.2.198.3Scalarpm1004vdcAlmAdddropClient3Westread-onlycurrentClient West Rx Side Active :This OID indicates the Client is active on West receiving side <Condtype> ADDDROP_CLIENT3_WEST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.38.2.1.2.198.4Scalarpm1004vdcAlmAdddropClient4Westread-onlycurrentClient West Rx Side Active :This OID indicates the Client is active on West receiving side <Condtype> ADDDROP_CLIENT4_WEST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.38.2.1.2.198.5Scalarpm1004vdcAlmAdddropClient5Westread-onlycurrentClient West Rx Side Active :This OID indicates the Client is active on West receiving side <Condtype> ADDDROP_CLIENT5_WEST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.38.2.1.2.198.6Scalarpm1004vdcAlmAdddropClient6Westread-onlycurrentClient West Rx Side Active :This OID indicates the Client is active on West receiving side <Condtype> ADDDROP_CLIENT6_WEST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.38.2.1.2.198.9Scalarpm1004vdcAlmAdddropClient1Eastread-onlycurrentClient East Rx Side Active :This OID indicates the Client is active on East receiving side <Condtype> ADDDROP_CLIENT1_EAST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.38.2.1.2.198.10Scalarpm1004vdcAlmAdddropClient2Eastread-onlycurrentClient East Rx Side Active :This OID indicates the Client is active on East receiving side <Condtype> ADDDROP_CLIENT2_EAST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.38.2.1.2.198.11Scalarpm1004vdcAlmAdddropClient3Eastread-onlycurrentClient East Rx Side Active :This OID indicates the Client is active on East receiving side <Condtype> ADDDROP_CLIENT3_EAST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.38.2.1.2.198.12Scalarpm1004vdcAlmAdddropClient4Eastread-onlycurrentClient East Rx Side Active :This OID indicates the Client is active on East receiving side <Condtype> ADDDROP_CLIENT4_EAST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.38.2.1.2.198.13Scalarpm1004vdcAlmAdddropClient5Eastread-onlycurrentClient East Rx Side Active :This OID indicates the Client is active on East receiving side <Condtype> ADDDROP_CLIENT5_EAST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.38.2.1.2.198.14Scalarpm1004vdcAlmAdddropClient6Eastread-onlycurrentClient East Rx Side Active :This OID indicates the Client is active on East receiving side <Condtype> ADDDROP_CLIENT6_EAST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.38.2.1.3Nodepm1004vdcAlmOtherCrit
1.3.6.1.4.1.20044.38.2.1.3.0Nodepm1004vdcAlmsynthAlm0
1.3.6.1.4.1.20044.38.2.1.3.0.9Scalarpm1004vdcAlmModGlobFailread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the PM <Condtype> MOD_GLOB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> sy…
1.3.6.1.4.1.20044.38.2.1.3.0.15Scalarpm1004vdcAlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.38.2.1.3.0.16Scalarpm1004vdcAlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.38.2.2Nodepm1004vdcAlmClient
1.3.6.1.4.1.20044.38.2.2.1Nodepm1004vdcAlmClientNurg
1.3.6.1.4.1.20044.38.2.2.1.48Tablepm1004vdcAlmsfpWarnDdmTablenot-accessiblecurrentList of pm1004vdcAlmsfpWarnDdm Article
1.3.6.1.4.1.20044.38.2.2.1.48.1Rowpm1004vdcAlmsfpWarnDdmEntrynot-accessiblecurrentRow definition for the pm1004vdcAlmsfpWarnDdm table
1.3.6.1.4.1.20044.38.2.2.1.48.1.1Columnpm1004vdcAlmsfpWarnDdmIndexread-onlycurrentIndex definition for the pm1004vdcAlmsfpWarnDdm table
1.3.6.1.4.1.20044.38.2.2.1.48.1.2Columnpm1004vdcAlmTxPwLowWngPortnread-onlycurrentClient SFP Tx Power Low Warning :Warning indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> TX…
1.3.6.1.4.1.20044.38.2.2.1.48.1.3Columnpm1004vdcAlmTxPwrHighWngPortnread-onlycurrentClient SFP Tx Power High Warning :Warning indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.38.2.2.1.48.1.4Columnpm1004vdcAlmTxBiasLowWngPortnread-onlycurrentClient SFP Bias Low Warning :Warning indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.38.2.2.1.48.1.5Columnpm1004vdcAlmTxBiasHighWngPortnread-onlycurrentClient SFP Bias High Warning :Warning indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.38.2.2.1.48.1.6Columnpm1004vdcAlmVccLowWngPortnread-onlycurrentClient SFP Power Supply Low Warning :Warning indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.38.2.2.1.48.1.7Columnpm1004vdcAlmVccHighWngPortnread-onlycurrentClient SFP Power Supply High Warning :Warning indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condty…
1.3.6.1.4.1.20044.38.2.2.1.48.1.8Columnpm1004vdcAlmTempLowWngPortnread-onlycurrentClient SFP Temp Low Warning :Warning indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> TEMP_LO…
1.3.6.1.4.1.20044.38.2.2.1.48.1.9Columnpm1004vdcAlmTempHighWngPortnread-onlycurrentClient SFP Temp High Warning :Warning indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> TEMP_…
1.3.6.1.4.1.20044.38.2.2.1.48.1.16Columnpm1004vdcAlmRxPwrLowWngPortnread-onlycurrentClient SFP Rx Power Low Warning :Warning indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> RX_…
1.3.6.1.4.1.20044.38.2.2.1.48.1.17Columnpm1004vdcAlmRxPwrHighWngPortnread-onlycurrentClient SFP Rx Power High Warning :Warning indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> R…
1.3.6.1.4.1.20044.38.2.2.1.56Tablepm1004vdcAlmsfpCritDdmTablenot-accessiblecurrentList of pm1004vdcAlmsfpCritDdm Article
1.3.6.1.4.1.20044.38.2.2.1.56.1Rowpm1004vdcAlmsfpCritDdmEntrynot-accessiblecurrentRow definition for the pm1004vdcAlmsfpCritDdm table
1.3.6.1.4.1.20044.38.2.2.1.56.1.1Columnpm1004vdcAlmsfpCritDdmIndexread-onlycurrentIndex definition for the pm1004vdcAlmsfpCritDdm table
1.3.6.1.4.1.20044.38.2.2.1.56.1.2Columnpm1004vdcAlmTxPwrLowCritPortnread-onlycurrentClient SFP Custom Tx Power Low :Custom Alarm indicating that the SFP output power of port is lower than the custom threshold defined in configuration <Help> Cu…
1.3.6.1.4.1.20044.38.2.2.1.56.1.3Columnpm1004vdcAlmTxPwrHighCritPortnread-onlycurrentClient SFP Custom Tx Power High :Custom Alarm indicating that the SFP output power of port is higher than the custom threshold defined in configuration <Help> …
1.3.6.1.4.1.20044.38.2.2.1.56.1.16Columnpm1004vdcAlmRxPwrLowCritPortnread-onlycurrentClient SFP Custom Rx Power Low :Custom Alarm indicating that the SFP input power of port is lower than the custom threshold defined in configuration <Help> Cus…
1.3.6.1.4.1.20044.38.2.2.1.56.1.17Columnpm1004vdcAlmRxPwrHighCritPortnread-onlycurrentClient SFP Custom Rx Power High :Custom Alarm indicating that the SFP input power of port is higher than the custom threshold defined in configuration <Help> C…
1.3.6.1.4.1.20044.38.2.2.2Nodepm1004vdcAlmClientUrg
1.3.6.1.4.1.20044.38.2.2.2.32Tablepm1004vdcAlmsfpAlmDdmTablenot-accessiblecurrentList of pm1004vdcAlmsfpAlmDdm Article
1.3.6.1.4.1.20044.38.2.2.2.32.1Rowpm1004vdcAlmsfpAlmDdmEntrynot-accessiblecurrentRow definition for the pm1004vdcAlmsfpAlmDdm table
1.3.6.1.4.1.20044.38.2.2.2.32.1.1Columnpm1004vdcAlmsfpAlmDdmIndexread-onlycurrentIndex definition for the pm1004vdcAlmsfpAlmDdm table
1.3.6.1.4.1.20044.38.2.2.2.32.1.2Columnpm1004vdcAlmTxPwrLowAlaPortnread-onlycurrentClient SFP Tx Power Low :Alarm indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> TX_PWR_LOW_A…
1.3.6.1.4.1.20044.38.2.2.2.32.1.3Columnpm1004vdcAlmTxPwrHighAlaPortnread-onlycurrentClient SFP Tx Power High :Alarm indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> TX_PWR_HIG…
1.3.6.1.4.1.20044.38.2.2.2.32.1.4Columnpm1004vdcAlmTxBiasLowAlaPortnread-onlycurrentClient SFP Bias Low :Alarm indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> TX_BIAS_LO…
1.3.6.1.4.1.20044.38.2.2.2.32.1.5Columnpm1004vdcAlmTxBiasHighAlaPortnread-onlycurrentClient SFP Bias High :Alarm indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype> TX_BIAS_…
1.3.6.1.4.1.20044.38.2.2.2.32.1.6Columnpm1004vdcAlmVccLowAlaPortnread-onlycurrentClient SFP Power Supply Low :Alarm indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype> VCC_LOW_…
1.3.6.1.4.1.20044.38.2.2.2.32.1.7Columnpm1004vdcAlmVccHighAlaPortnread-onlycurrentClient SFP Power Supply High :Alarm indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condtype> VCC_HI…
1.3.6.1.4.1.20044.38.2.2.2.32.1.8Columnpm1004vdcAlmTempLowAlaPortnread-onlycurrentClient SFP Temp Low :Alarm indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> TEMP_LOW_ALA_1 <P…
1.3.6.1.4.1.20044.38.2.2.2.32.1.9Columnpm1004vdcAlmTempHighAlaPortnread-onlycurrentClient SFP Temp High :Alarm indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> TEMP_HIGH_ALA_1…
1.3.6.1.4.1.20044.38.2.2.2.32.1.16Columnpm1004vdcAlmRxPwrLowAlaPortnread-onlycurrentClient SFP Rx Power Low :Alarm indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> RX_PWR_LOW_AL…
1.3.6.1.4.1.20044.38.2.2.2.32.1.17Columnpm1004vdcAlmRxPwrHighAlaPortnread-onlycurrentClient SFP Rx Power High :Alarm indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> RX_PWR_HIGH…
1.3.6.1.4.1.20044.38.2.2.3Nodepm1004vdcAlmClientCrit
1.3.6.1.4.1.20044.38.2.2.3.8Tablepm1004vdcAlmsynthAlmPortTablenot-accessiblecurrentList of pm1004vdcAlmsynthAlmPort Article
1.3.6.1.4.1.20044.38.2.2.3.8.1Rowpm1004vdcAlmsynthAlmPortEntrynot-accessiblecurrentRow definition for the pm1004vdcAlmsynthAlmPort table
1.3.6.1.4.1.20044.38.2.2.3.8.1.1Columnpm1004vdcAlmsynthAlmPortIndexread-onlycurrentIndex definition for the pm1004vdcAlmsynthAlmPort table
1.3.6.1.4.1.20044.38.2.2.3.8.1.2Columnpm1004vdcAlmSfpAbsentPortnread-onlycurrentClient Optical Module Absent :This OID indicates that the SFP module is not present in the client port (only significant on Client6-GbE port). <Help> This alar…
1.3.6.1.4.1.20044.38.2.2.3.8.1.3Columnpm1004vdcAlmDdmAbsentPortnread-onlycurrentDDM Supported On Client SFP :This OID indicates that the Client SFP module supports the Digital Diagnostic Monitoring function (only significant on Client6-GbE…
1.3.6.1.4.1.20044.38.2.2.3.8.1.5Columnpm1004vdcAlmHwFailAccPortnread-onlycurrentClient HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Condtype> HW_FAIL_ACC_1 <Probcause> equipmentMalfunction (16)…
1.3.6.1.4.1.20044.38.2.2.3.8.1.6Columnpm1004vdcAlmDwLsdPortnread-onlycurrentClient Signal Shutdown :This OID indicates the Client SFP transmitter output is ON. <Help> This status indicates if the client transceiver is ON or OFF <Condty…
1.3.6.1.4.1.20044.38.2.2.3.8.1.7Columnpm1004vdcAlmClientLocalOosTxPortnread-onlycurrentTx Client Port In Service :This OID indicates that the local Tx Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local T…
1.3.6.1.4.1.20044.38.2.2.3.8.1.8Columnpm1004vdcAlmClientLocalOosRxPortnread-onlycurrentRx Client Port In Service :This OID indicates that the local Rx Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local R…
1.3.6.1.4.1.20044.38.2.2.3.8.1.9Columnpm1004vdcAlmDwCaisPortnread-onlycurrentClient AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indictaes if a Client Alarm Indication Signal is…
1.3.6.1.4.1.20044.38.2.2.3.8.1.10Columnpm1004vdcAlmSfpDdmWarningPortnread-onlycurrentWarning On Client SFP DDM :This OID indicates a warning is being received from the Client SFP DDM (only significant on Client6-GbE port) <Help> This alarm indi…
1.3.6.1.4.1.20044.38.2.2.3.8.1.11Columnpm1004vdcAlmSfpDdmAlmPortnread-onlycurrentAlarm On Client SFP DDM :This OID indicates an alarm is being received from the Client SFP DDM (only significant on Client6-GbE port) <Help> This alarm indicat…
1.3.6.1.4.1.20044.38.2.2.3.8.1.12Columnpm1004vdcAlmSfpDdmCritPortnread-onlycurrentCustom Alarm On Client SFP DDM :This OID indicates a Custom alarm is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Custom Alarm h…
1.3.6.1.4.1.20044.38.2.2.3.8.1.13Columnpm1004vdcAlmFailAccPortnread-onlycurrentClient Access Fail :This OID indicates a failure on the Client port <Condtype> FAIL_ACC_1 <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12)…
1.3.6.1.4.1.20044.38.2.2.3.8.1.16Columnpm1004vdcAlmClientActivePortnread-onlycurrentClient Sink (Line1 Or Line2) :This bit indicates the Client #n is active on receive side <Help> This status indicates whether the Client is extracted from Line…
1.3.6.1.4.1.20044.38.2.2.3.8.1.17Columnpm1004vdcAlmUpCsfPortnread-onlycurrentClient Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu…
1.3.6.1.4.1.20044.38.2.2.3.16Tablepm1004vdcAlmaccessioAlmTablenot-accessiblecurrentList of pm1004vdcAlmaccessioAlm Article
1.3.6.1.4.1.20044.38.2.2.3.16.1Rowpm1004vdcAlmaccessioAlmEntrynot-accessiblecurrentRow definition for the pm1004vdcAlmaccessioAlm table
1.3.6.1.4.1.20044.38.2.2.3.16.1.1Columnpm1004vdcAlmaccessioAlmIndexread-onlycurrentIndex definition for the pm1004vdcAlmaccessioAlm table
1.3.6.1.4.1.20044.38.2.2.3.16.1.2Columnpm1004vdcAlmDwLasFailPortnread-onlycurrentClient SFP Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the client port. This alarm reports the transmitter failure alarm …
1.3.6.1.4.1.20044.38.2.2.3.16.1.5Columnpm1004vdcAlmUpLosPortnread-onlycurrentClient Input Loss Of Signal :This OID indicates that no signal is present on the client port <Help> This alarm indicates if a signal is detected on the client …
1.3.6.1.4.1.20044.38.2.2.3.72Tablepm1004vdcAlmmapperDeAlmTablenot-accessiblecurrentList of pm1004vdcAlmmapperDeAlm Article
1.3.6.1.4.1.20044.38.2.2.3.72.1Rowpm1004vdcAlmmapperDeAlmEntrynot-accessiblecurrentRow definition for the pm1004vdcAlmmapperDeAlm table
1.3.6.1.4.1.20044.38.2.2.3.72.1.1Columnpm1004vdcAlmmapperDeAlmIndexread-onlycurrentIndex definition for the pm1004vdcAlmmapperDeAlm table
1.3.6.1.4.1.20044.38.2.2.3.72.1.2Columnpm1004vdcAlmUpAccOosPortnread-onlycurrentClient Loss Of Synchro :This OID indicates the upstream client input port has lost synchronization on its decoder <Help> This alarms indicates if the input cli…
1.3.6.1.4.1.20044.38.2.2.3.72.1.11Columnpm1004vdcAlmUpBufferOvlPortnread-onlycurrentClient Upstream Buffer Overload :This OID indicates that the rate adaptation buffer for client port is in overload. <Help> This alarm indicates if there is a u…
1.3.6.1.4.1.20044.38.2.2.3.72.1.12Columnpm1004vdcAlmDwCsfDetPortnread-onlycurrentClient Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client…
1.3.6.1.4.1.20044.38.2.2.3.72.1.15Columnpm1004vdcAlmDwBufferOvlPortnread-onlycurrentClient Downstream Buffer Overload :This OID indicates that the de-mapper buffer for client port is in overload. <Help> This alarm indicates if there is a downs…
1.3.6.1.4.1.20044.38.2.2.3.112Tablepm1004vdcAlmvideoProtocolStatusTablenot-accessiblecurrentList of pm1004vdcAlmvideoProtocolStatus Article
1.3.6.1.4.1.20044.38.2.2.3.112.1Rowpm1004vdcAlmvideoProtocolStatusEntrynot-accessiblecurrentRow definition for the pm1004vdcAlmvideoProtocolStatus table
1.3.6.1.4.1.20044.38.2.2.3.112.1.1Columnpm1004vdcAlmvideoProtocolStatusIndexread-onlycurrentIndex definition for the pm1004vdcAlmvideoProtocolStatus table
1.3.6.1.4.1.20044.38.2.2.3.112.1.2Columnpm1004vdcAlmSdiTxPortnread-onlycurrentSDI Detected On Tx :This OID indicates that the SDI protocol has been detected on the transmit side of the port (only significant on Video2 to Video 5 ports) <…
1.3.6.1.4.1.20044.38.2.2.3.112.1.3Columnpm1004vdcAlmHdSdiPalTxPortnread-onlycurrentHD-SDI-PAL Detected On Tx :This OID indicates that the HD-SDI-PAL protocol has been detected on the transmit side of the port (only significant on Video2 to Vi…
1.3.6.1.4.1.20044.38.2.2.3.112.1.4Columnpm1004vdcAlmHdSdiNtscTxPortnread-onlycurrentHD-SDI-NTSC Detected On Tx :This OID indicates that the HD-SDI-NTSC protocol has been detected on the transmit side of the port (only significant on Video2 to …
1.3.6.1.4.1.20044.38.2.2.3.112.1.5Columnpm1004vdcAlmDvbAsiTxPortnread-onlycurrentDVB-ASI Detected On Tx :This OID indicates that the DVB-ASI protocol has been detected on the transmit side of the port (only significant on Video2 to Video 5 …
1.3.6.1.4.1.20044.38.2.2.3.112.1.6Columnpm1004vdcAlmFastEtherTxPortnread-onlycurrentFast Ethernet Detected On Tx :This OID indicates that the Fast Ethernet protocol has been detected on the port (only significant on Client1-RJ45 port) <Help> T…
1.3.6.1.4.1.20044.38.2.2.3.112.1.7Columnpm1004vdcAlmGbeTxPortnread-onlycurrentGigabit Ethernet Detected On Tx :This OID indicates that the Gigabit Ethernet protocol has been detected on the port (only significant on Client6-GbE port) <He…
1.3.6.1.4.1.20044.38.2.2.3.112.1.10Columnpm1004vdcAlmSdiRxPortnread-onlycurrentSDI Detected On Rx :This OID indicates that the SDI protocol has been detected on the receive side of the port (only significant on Video2 to Video 5 ports) <H…
1.3.6.1.4.1.20044.38.2.2.3.112.1.11Columnpm1004vdcAlmHdSdiPalRxPortnread-onlycurrentHD-SDI-PAL Detected On Rx :This OID indicates that the HD-SDI-PAL protocol has been detected on the receive side of the port (only significant on Video2 to Vid…
1.3.6.1.4.1.20044.38.2.2.3.112.1.12Columnpm1004vdcAlmHdSdiNtscRxPortnread-onlycurrentHD-SDI-NTSC Detected On Rx :This OID indicates that the HD-SDI-NTSC protocol has been detected on the receive side of the port (only significant on Video2 to V…
1.3.6.1.4.1.20044.38.2.2.3.112.1.13Columnpm1004vdcAlmDvbAsiRxPortnread-onlycurrentDVB-ASI Detected On Rx :This OID indicates that the DVB-ASI protocol has been detected on the receive side of the port (only significant on Video2 to Video 5 p…
1.3.6.1.4.1.20044.38.2.2.3.112.1.14Columnpm1004vdcAlmFastEtherRxPortnread-onlycurrentFast Ethernet Detected On Rx :This OID indicates that the Fast Ethernet protocol has been detected on the port (only significant on Client1-RJ45 port) <Help> T…
1.3.6.1.4.1.20044.38.2.2.3.112.1.15Columnpm1004vdcAlmGbeRxPortnread-onlycurrentGigabit Ethernet Detected On Rx :This OID indicates that the Gigabit Ethernet protocol has been detected on the port (only significant on Client6-GbE port) <He…
1.3.6.1.4.1.20044.38.2.3Nodepm1004vdcAlmLine
1.3.6.1.4.1.20044.38.2.3.1Nodepm1004vdcAlmLineNurg
1.3.6.1.4.1.20044.38.2.3.1.209Tablepm1004vdcAlmlineXfp1WarningsTablenot-accessiblecurrentList of pm1004vdcAlmlineXfp1Warnings Article
1.3.6.1.4.1.20044.38.2.3.1.209.1Rowpm1004vdcAlmlineXfp1WarningsEntrynot-accessiblecurrentRow definition for the pm1004vdcAlmlineXfp1Warnings table
1.3.6.1.4.1.20044.38.2.3.1.209.1.1Columnpm1004vdcAlmlineXfp1WarningsIndexread-onlycurrentIndex definition for the pm1004vdcAlmlineXfp1Warnings table
1.3.6.1.4.1.20044.38.2.3.1.209.1.2Columnpm1004vdcAlmTxPowerLowWarningPortnread-onlycurrentLine Optical Tx Power Low Warning :Warning indicating that the XFP/OTX transmitter transmitter output power is lower than the threshold value written in the XF…
1.3.6.1.4.1.20044.38.2.3.1.209.1.3Columnpm1004vdcAlmTxPowerHighWarningPortnread-onlycurrentLine Optical Tx Power High Warning :Warning indicating that the XFP/OTX transmitter transmitter output power is higher than the threshold value written in the …
1.3.6.1.4.1.20044.38.2.3.1.209.1.4Columnpm1004vdcAlmTxBiasLowWarningPortnread-onlycurrentLine Transceiver Bias Low Warning :Warning indicating that the XFP/OTX transmitter laser bias current is lower than the threshold value written in the XFP/OTX …
1.3.6.1.4.1.20044.38.2.3.1.209.1.5Columnpm1004vdcAlmTxBiasHighWarningPortnread-onlycurrentLine Transceiver Bias High Warning :Warning indicating that the XFP/OTX transmitter laser bias current is higher than the threshold value written in the XFP EE…
1.3.6.1.4.1.20044.38.2.3.1.209.1.8Columnpm1004vdcAlmTempLowWarningPortnread-onlycurrentLine Transceiver Temp Low Warning :Warning indicating that the XFP/OTX temperature is lower than the threshold value written in the XFP/OTX EEPROM <Condtype> T…
1.3.6.1.4.1.20044.38.2.3.1.209.1.9Columnpm1004vdcAlmTempHighWarningPortnread-onlycurrentLine Transceiver Temp High Warning :Warning indicating that the XFP/OTX temperature is higher than the threshold value written in the XFP EEPROM <Condtype> TEM…
1.3.6.1.4.1.20044.38.2.3.1.209.1.16Columnpm1004vdcAlmRxPowerLowWarningPortnread-onlycurrentLine Optical Rx Power Low Warning :Warning indicating that the XFP received optical power is lower than the threshold value written in the XFP EEPROM <Condtype…
1.3.6.1.4.1.20044.38.2.3.1.209.1.17Columnpm1004vdcAlmRxPowerHighWarningPortnread-onlycurrentLine Optical Rx Power High Warning :Warning indicating that the XFP received optical power is higher than the threshold value written in the XFP EEPROM <Condty…
1.3.6.1.4.1.20044.38.2.3.1.225Tablepm1004vdcAlmlineOtx1TlhWarningsTablenot-accessiblecurrentList of pm1004vdcAlmlineOtx1TlhWarnings Article
1.3.6.1.4.1.20044.38.2.3.1.225.1Rowpm1004vdcAlmlineOtx1TlhWarningsEntrynot-accessiblecurrentRow definition for the pm1004vdcAlmlineOtx1TlhWarnings table
1.3.6.1.4.1.20044.38.2.3.1.225.1.1Columnpm1004vdcAlmlineOtx1TlhWarningsIndexread-onlycurrentIndex definition for the pm1004vdcAlmlineOtx1TlhWarnings table
1.3.6.1.4.1.20044.38.2.3.1.225.1.6Columnpm1004vdcAlmLineModulatorAgingHighWarningPortnread-onlycurrentLine Modulator Aging High Warning :Warning indicating the Line OTX TLH modulator aging is higher than the threshold written in the EEPROM <Condtype> LINE_MODUL…
1.3.6.1.4.1.20044.38.2.3.1.225.1.7Columnpm1004vdcAlmLineAgingHighWarningPortnread-onlycurrentLine OTX TLH Aging High Warning :Warning indicating the Line OTX TLH aging is higher than the threshold written in the EEPROM <Condtype> LINE_AGING_HIGH_WARNIN…
1.3.6.1.4.1.20044.38.2.3.1.225.1.13Columnpm1004vdcAlmLineFreqDevHighWarningPortnread-onlycurrentLine Freq. Deviation High Warning :Warning indicating the Line OTX TLH frequency deviation is higher than the threshold written in the EEPROM <Condtype> LINE_F…
1.3.6.1.4.1.20044.38.2.3.1.225.1.15Columnpm1004vdcAlmLineLaserTempHighWarningPortnread-onlycurrentLine Laser Temp. High Warning :Warning indicating the Line OTX TLH laser temperature is higher than the threshold written in the EEPROM <Condtype> LINE_LASER_T…
1.3.6.1.4.1.20044.38.2.3.2Nodepm1004vdcAlmLineUrg
1.3.6.1.4.1.20044.38.2.3.2.208Tablepm1004vdcAlmlineXfp1AlarmTablenot-accessiblecurrentList of pm1004vdcAlmlineXfp1Alarm Article
1.3.6.1.4.1.20044.38.2.3.2.208.1Rowpm1004vdcAlmlineXfp1AlarmEntrynot-accessiblecurrentRow definition for the pm1004vdcAlmlineXfp1Alarm table
1.3.6.1.4.1.20044.38.2.3.2.208.1.1Columnpm1004vdcAlmlineXfp1AlarmIndexread-onlycurrentIndex definition for the pm1004vdcAlmlineXfp1Alarm table
1.3.6.1.4.1.20044.38.2.3.2.208.1.2Columnpm1004vdcAlmTxPowerLowAlarmPortnread-onlycurrentLine Optical Tx Power Low :Alarm indicating that the XFP/OTX transmitter transmitter output power is lower than the threshold value written in the XFP/OTX EEPR…
1.3.6.1.4.1.20044.38.2.3.2.208.1.3Columnpm1004vdcAlmTxPowerHighAlarmPortnread-onlycurrentLine Optical Tx Power High :Alarm indicating that the XFP/OTX transmitter transmitter output power is higher than the threshold value written in the XFP EEPROM…
1.3.6.1.4.1.20044.38.2.3.2.208.1.4Columnpm1004vdcAlmTxBiasLowAlarmPortnread-onlycurrentLine Transceiver Bias Low :Alarm indicating that the XFP/OTX transmitter laser bias current is lower than the threshold value written in the XFP/OTX EEPROM <Co…
1.3.6.1.4.1.20044.38.2.3.2.208.1.5Columnpm1004vdcAlmTxBiasHighAlarmPortnread-onlycurrentLine Transceiver Bias High :Alarm indicating that the XFP/OTX transmitter laser bias current is higher than the threshold value written in the XFP EEPROM <Cond…
1.3.6.1.4.1.20044.38.2.3.2.208.1.8Columnpm1004vdcAlmTempLowAlarmPortnread-onlycurrentLine Transceiver Temp Low :Alarm indicating that the XFP/OTX temperature is lower than the threshold value written in the XFP/OTX EEPROM <Condtype> TEMP_LOW_AL…
1.3.6.1.4.1.20044.38.2.3.2.208.1.9Columnpm1004vdcAlmTempHighAlarmPortnread-onlycurrentLine Transceiver Temp High :Alarm indicating that the XFP/OTX temperature is higher than the threshold value written in the XFP EEPROM <Condtype> TEMP_HIGH_ALA…
1.3.6.1.4.1.20044.38.2.3.2.208.1.16Columnpm1004vdcAlmRxPowerLowAlarmPortnread-onlycurrentLine Optical Rx Power Low :Alarm indicating that the XFP received optical power is lower than the threshold value written in the XFP EEPROM <Condtype> RX_POWER…
1.3.6.1.4.1.20044.38.2.3.2.208.1.17Columnpm1004vdcAlmRxPowerHighAlarmPortnread-onlycurrentLine Optical Rx Power High :Alarm indicating that the XFP received optical power is higher than the threshold value written in the XFP EEPROM <Condtype> RX_POW…
1.3.6.1.4.1.20044.38.2.3.2.210Tablepm1004vdcAlmlineXfp1CritTablenot-accessiblecurrentList of pm1004vdcAlmlineXfp1Crit Article
1.3.6.1.4.1.20044.38.2.3.2.210.1Rowpm1004vdcAlmlineXfp1CritEntrynot-accessiblecurrentRow definition for the pm1004vdcAlmlineXfp1Crit table
1.3.6.1.4.1.20044.38.2.3.2.210.1.1Columnpm1004vdcAlmlineXfp1CritIndexread-onlycurrentIndex definition for the pm1004vdcAlmlineXfp1Crit table
1.3.6.1.4.1.20044.38.2.3.2.210.1.2Columnpm1004vdcAlmTxPowerLowCritPortnread-onlycurrentLine Custom Tx Power Low :Custom Alarm indicating that the XFP/OTX output power of port is lower than the custom threshold defined in configuration <Help> Cust…
1.3.6.1.4.1.20044.38.2.3.2.210.1.3Columnpm1004vdcAlmTxPowerHighCritPortnread-onlycurrentLine Custom Tx Power High :Custom Alarm indicating that the XFP/OTX output power of port is higher than the custom threshold defined in configuration <Help> Cu…
1.3.6.1.4.1.20044.38.2.3.2.210.1.16Columnpm1004vdcAlmRxPowerLowCritPortnread-onlycurrentLine Custom Rx Power Low :Custom Alarm indicating that the XFP/OTX input power of port is lower than the custom threshold defined in configuration <Help> Custo…
1.3.6.1.4.1.20044.38.2.3.2.210.1.17Columnpm1004vdcAlmRxPowerHighCritPortnread-onlycurrentLine Custom Rx Power High :Custom Alarm indicating that the XFP/OTX input power of port is higher than the custom threshold defined in configuration <Help> Cus…
1.3.6.1.4.1.20044.38.2.3.2.212Tablepm1004vdcAlmlineXfp1SupplyAlarmTablenot-accessiblecurrentList of pm1004vdcAlmlineXfp1SupplyAlarm Article
1.3.6.1.4.1.20044.38.2.3.2.212.1Rowpm1004vdcAlmlineXfp1SupplyAlarmEntrynot-accessiblecurrentRow definition for the pm1004vdcAlmlineXfp1SupplyAlarm table
1.3.6.1.4.1.20044.38.2.3.2.212.1.1Columnpm1004vdcAlmlineXfp1SupplyAlarmIndexread-onlycurrentIndex definition for the pm1004vdcAlmlineXfp1SupplyAlarm table
1.3.6.1.4.1.20044.38.2.3.2.212.1.2Columnpm1004vdcAlmVee5LowAlarmPortnread-onlycurrentVEE5 Power Supply Low :Alarm indicating the XFP/OTX VEE5 power supply is lower than the threshold written in the EEPROM <Condtype> VEE5_LOW_ALARM_1 <Probcause>…
1.3.6.1.4.1.20044.38.2.3.2.212.1.3Columnpm1004vdcAlmVee5HighAlarmPortnread-onlycurrentVEE5 Power Supply High :Alarm indicating the XFP/OTX VEE5 power supply is higher than the threshold written in the EEPROM <Condtype> VEE5_HIGH_ALARM_1 <Probcau…
1.3.6.1.4.1.20044.38.2.3.2.212.1.4Columnpm1004vdcAlmVcc2LowAlarmPortnread-onlycurrentVCC2 Power Supply Low :Alarm indicating the XFP/OTX VCC2 power supply is lower than the threshold written in the EEPROM <Condtype> VCC2_LOW_ALARM_1 <Probcause>…
1.3.6.1.4.1.20044.38.2.3.2.212.1.5Columnpm1004vdcAlmVcc2HighAlarmPortnread-onlycurrentVCC2 Power Supply High :Alarm indicating the XFP/OTX VCC2 power supply is higher than the threshold written in the EEPROM <Condtype> VCC2_HIGH_ALARM_1 <Probcau…
1.3.6.1.4.1.20044.38.2.3.2.212.1.6Columnpm1004vdcAlmVcc3LowAlarmPortnread-onlycurrentVCC3 Power Supply Low :Alarm indicating the XFP/OTX VCC3 power supply is lower than the threshold written in the EEPROM <Condtype> VCC3_LOW_ALARM_1 <Probcause>…
1.3.6.1.4.1.20044.38.2.3.2.212.1.7Columnpm1004vdcAlmVcc3HighAlarmPortnread-onlycurrentVCC3 Power Supply High :Alarm indicating the XFP/OTX VCC3 power supply is higher than the threshold written in the EEPROM <Condtype> VCC3_HIGH_ALARM_1 <Probcau…
1.3.6.1.4.1.20044.38.2.3.2.212.1.8Columnpm1004vdcAlmVcc5LowAlarmPortnread-onlycurrentVCC5 Power Supply Low :Alarm indicating the XFP/OTX VCC5 power supply is lower than the threshold written in the EEPROM <Condtype> VCC5_LOW_ALARM_1 <Probcause>…
1.3.6.1.4.1.20044.38.2.3.2.212.1.9Columnpm1004vdcAlmVcc5HighAlarmPortnread-onlycurrentVCC5 Power Supply High :Alarm indicating the XFP/OTX VCC5 power supply is higher than the threshold written in the EEPROM <Condtype> VCC5_HIGH_ALARM_1 <Probcau…
1.3.6.1.4.1.20044.38.2.3.2.212.1.10Columnpm1004vdcAlmVee5LowWarningPortnread-onlycurrentVEE5 Power Supply Low Warning :Warning indicating the XFP/OTX VEE5 power supply is lower than the threshold written in the EEPROM <Condtype> VEE5_LOW_WARNING_1…
1.3.6.1.4.1.20044.38.2.3.2.212.1.11Columnpm1004vdcAlmVee5HighWarningPortnread-onlycurrentVEE5 Power Supply High Warning :Warning indicating the XFP/OTX VEE5 power supply is higher than the threshold written in the EEPROM <Condtype> VEE5_HIGH_WARNIN…
1.3.6.1.4.1.20044.38.2.3.2.212.1.12Columnpm1004vdcAlmVcc2LowWarningPortnread-onlycurrentVCC2 Power Supply Low Warning :Warning indicating the XFP/OTX VCC2 power supply is lower than the threshold written in the EEPROM <Condtype> VCC2_LOW_WARNING_1…
1.3.6.1.4.1.20044.38.2.3.2.212.1.13Columnpm1004vdcAlmVcc2HighWarningPortnread-onlycurrentVCC2 Power Supply High Warning :Warning indicating the XFP/OTX VCC2 power supply is higher than the threshold written in the EEPROM <Condtype> VCC2_HIGH_WARNIN…
1.3.6.1.4.1.20044.38.2.3.2.212.1.14Columnpm1004vdcAlmVcc3LowWarningPortnread-onlycurrentVCC3 Power Supply Low Warning :Warning indicating the XFP/OTX VCC3 power supply is lower than the threshold written in the EEPROM <Condtype> VCC3_LOW_WARNING_1…
1.3.6.1.4.1.20044.38.2.3.2.212.1.15Columnpm1004vdcAlmVcc3HighWarningPortnread-onlycurrentVCC3 Power Supply High Warning :Warning indicating the XFP/OTX VCC3 power supply is higher than the threshold written in the EEPROM <Condtype> VCC3_HIGH_WARNIN…
1.3.6.1.4.1.20044.38.2.3.2.212.1.16Columnpm1004vdcAlmVcc5LowWarningPortnread-onlycurrentVCC5 Power Supply Low Warning :Warning indicating the XFP/OTX VCC5 power supply is lower than the threshold written in the EEPROM <Condtype> VCC5_LOW_WARNING_1…
1.3.6.1.4.1.20044.38.2.3.2.212.1.17Columnpm1004vdcAlmVcc5HighWarningPortnread-onlycurrentVCC5 Power Supply High Warning :Warning indicating the XFP/OTX VCC5 power supply is higher than the threshold written in the EEPROM <Condtype> VCC5_HIGH_WARNIN…
1.3.6.1.4.1.20044.38.2.3.2.224Tablepm1004vdcAlmlineOtx1TlhAlarmsTablenot-accessiblecurrentList of pm1004vdcAlmlineOtx1TlhAlarms Article
1.3.6.1.4.1.20044.38.2.3.2.224.1Rowpm1004vdcAlmlineOtx1TlhAlarmsEntrynot-accessiblecurrentRow definition for the pm1004vdcAlmlineOtx1TlhAlarms table
1.3.6.1.4.1.20044.38.2.3.2.224.1.1Columnpm1004vdcAlmlineOtx1TlhAlarmsIndexread-onlycurrentIndex definition for the pm1004vdcAlmlineOtx1TlhAlarms table
1.3.6.1.4.1.20044.38.2.3.2.224.1.6Columnpm1004vdcAlmLineModulatorAgingHighAlaPortnread-onlycurrentLine Modulator Aging High Alarm :Alarm indicating the Line OTX TLH modulator aging is higher than the threshold written in the EEPROM <Condtype> LINE_MODULATOR…
1.3.6.1.4.1.20044.38.2.3.2.224.1.7Columnpm1004vdcAlmLineAgingHighAlaPortnread-onlycurrentLine OTX TLH Aging High Alarm :Alarm indicating the Line OTX TLH aging is higher than the threshold written in the EEPROM <Condtype> LINE_AGING_HIGH_ALA_1 <Pro…
1.3.6.1.4.1.20044.38.2.3.2.224.1.13Columnpm1004vdcAlmLineFreqDevHighAlaPortnread-onlycurrentLine Freq. Deviation High Alarm :Alarm indicating the Line OTX TLH frequency deviation is higher than the threshold written in the EEPROM <Condtype> LINE_FREQ_…
1.3.6.1.4.1.20044.38.2.3.2.224.1.15Columnpm1004vdcAlmLineLaserTempHighAlaPortnread-onlycurrentLine Laser Temp. High Alarm :Alarm indicating the Line OTX TLH laser temperature is higher than the threshold written in the EEPROM <Condtype> LINE_LASER_TEMP_…
1.3.6.1.4.1.20044.38.2.3.3Nodepm1004vdcAlmLineCrit
1.3.6.1.4.1.20044.38.2.3.3.7Tablepm1004vdcAlmsynthAlmLineTablenot-accessiblecurrentList of pm1004vdcAlmsynthAlmLine Article
1.3.6.1.4.1.20044.38.2.3.3.7.1Rowpm1004vdcAlmsynthAlmLineEntrynot-accessiblecurrentRow definition for the pm1004vdcAlmsynthAlmLine table
1.3.6.1.4.1.20044.38.2.3.3.7.1.1Columnpm1004vdcAlmsynthAlmLineIndexread-onlycurrentIndex definition for the pm1004vdcAlmsynthAlmLine table
1.3.6.1.4.1.20044.38.2.3.3.7.1.2Columnpm1004vdcAlmXfpAbsentPortnread-onlycurrentLine Optical Module Absent :This OID indicates that the line optical interface (XFP or OTX) is not plugged in. <Help> This alarm indicates if the line transcei…
1.3.6.1.4.1.20044.38.2.3.3.7.1.3Columnpm1004vdcAlmXfpInitNotComplPortnread-onlycurrentLine Optical Module Ready :This OID indicates that the optical interface (XFP or OTX) is not operational. <Help> This status indicates if the line transceiver …
1.3.6.1.4.1.20044.38.2.3.3.7.1.5Columnpm1004vdcAlmLineHwFailPortnread-onlycurrentLine Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Condtype> LINE_HW_FAIL <Probcause> equipmentMalfunction (1…
1.3.6.1.4.1.20044.38.2.3.3.7.1.6Columnpm1004vdcAlmXfpTxOffPortnread-onlycurrentLine Optical Module Laser Shutdown :This OID indicates the line optical output power is on <Help> This status indicates if the line transceiver laser is ON or …
1.3.6.1.4.1.20044.38.2.3.3.7.1.7Columnpm1004vdcAlmLineLocalOosPortnread-onlycurrentLine Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service…
1.3.6.1.4.1.20044.38.2.3.3.7.1.10Columnpm1004vdcAlmLineDdmWarningPortnread-onlycurrentWarning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Warni…
1.3.6.1.4.1.20044.38.2.3.3.7.1.11Columnpm1004vdcAlmLineDdmAlmPortnread-onlycurrentAlarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Alarm ha…
1.3.6.1.4.1.20044.38.2.3.3.7.1.12Columnpm1004vdcAlmLineDdmCritPortnread-onlycurrentCustom Alarm On Line XFP/OTX DDM :This OID indicates a Custom alarm is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Cu…
1.3.6.1.4.1.20044.38.2.3.3.7.1.13Columnpm1004vdcAlmLineFailPortnread-onlycurrentLine Port Failure :This OID indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12) <Po…
1.3.6.1.4.1.20044.38.2.3.3.7.1.17Columnpm1004vdcAlmLineActivePortnread-onlycurrentLine Active :This bit indicates the line #n is active on receive side <Help> This status indicates whether the line is active or standby. <Condtype> LINE_ACTIV…
1.3.6.1.4.1.20044.38.2.3.3.128Tablepm1004vdcAlmdfrmAlmTablenot-accessiblecurrentList of pm1004vdcAlmdfrmAlm Article
1.3.6.1.4.1.20044.38.2.3.3.128.1Rowpm1004vdcAlmdfrmAlmEntrynot-accessiblecurrentRow definition for the pm1004vdcAlmdfrmAlm table
1.3.6.1.4.1.20044.38.2.3.3.128.1.1Columnpm1004vdcAlmdfrmAlmIndexread-onlycurrentIndex definition for the pm1004vdcAlmdfrmAlm table
1.3.6.1.4.1.20044.38.2.3.3.128.1.5Columnpm1004vdcAlmDwLossofsyncPortnread-onlycurrentLoss Of Synchronisation :This OID indicates the upstream line input port is in Loss of Synchronization. <Help> This alarms indicates if the input signal is cor…
1.3.6.1.4.1.20044.38.2.3.3.133Tablepm1004vdcAlmlineSyncAlarmsTablenot-accessiblecurrentList of pm1004vdcAlmlineSyncAlarms Article
1.3.6.1.4.1.20044.38.2.3.3.133.1Rowpm1004vdcAlmlineSyncAlarmsEntrynot-accessiblecurrentRow definition for the pm1004vdcAlmlineSyncAlarms table
1.3.6.1.4.1.20044.38.2.3.3.133.1.1Columnpm1004vdcAlmlineSyncAlarmsIndexread-onlycurrentIndex definition for the pm1004vdcAlmlineSyncAlarms table
1.3.6.1.4.1.20044.38.2.3.3.133.1.13Columnpm1004vdcAlmDwLockerrPortnread-onlycurrentDownstream Clock Lock Error :This OID indicates that the deserializer input 10 Gb/s clock recovery is not locked. <Condtype> DW_LOCKERR <Probcause> receiveFail…
1.3.6.1.4.1.20044.38.2.3.3.133.1.14Columnpm1004vdcAlmUpLockerrPortnread-onlycurrentUpstream Clock Lock Error :This OID indicates that the serializer output 10 Gb/s clock multiplier unit is not locked. <Condtype> UP_LOCKERR <Probcause> receive…
1.3.6.1.4.1.20044.38.2.3.3.133.1.17Columnpm1004vdcAlmDwLosPortnread-onlycurrentLine Input Loss Of Signal :This OID indicates a loss of signal on the 10 Gb/s input. <Help> This alarm indicates if an optical signal is detected on the line t…
1.3.6.1.4.1.20044.38.2.3.3.211Tablepm1004vdcAlmlineXfp1AlarmsTablenot-accessiblecurrentList of pm1004vdcAlmlineXfp1Alarms Article
1.3.6.1.4.1.20044.38.2.3.3.211.1Rowpm1004vdcAlmlineXfp1AlarmsEntrynot-accessiblecurrentRow definition for the pm1004vdcAlmlineXfp1Alarms table
1.3.6.1.4.1.20044.38.2.3.3.211.1.1Columnpm1004vdcAlmlineXfp1AlarmsIndexread-onlycurrentIndex definition for the pm1004vdcAlmlineXfp1Alarms table
1.3.6.1.4.1.20044.38.2.3.3.211.1.3Columnpm1004vdcAlmModNrPortnread-onlycurrentLine Optical Module Not Ready :This OID indicates that the module is unable to determine correct data. <Help> This alarm indicates if the line transceiver is r…
1.3.6.1.4.1.20044.38.2.3.3.211.1.4Columnpm1004vdcAlmRxCdrNotLockedPortnread-onlycurrentLine Optical Rx CDR Unlocked :This OID indicates that a loss of lock on the receiving side CDR has been detected <Help> This alarm indicates if the Rx CDR is l…
1.3.6.1.4.1.20044.38.2.3.3.211.1.6Columnpm1004vdcAlmRxNrPortnread-onlycurrentLine Optical Rx Not Ready :This OID indicates that a condition has arisen leading to invalid data on the receiving side. <Help> This alarm indicates if the Rx …
1.3.6.1.4.1.20044.38.2.3.3.211.1.7Columnpm1004vdcAlmTxCdrNotLockedPortnread-onlycurrentLine Optical Tx CDR Unlocked :This OID indicates a loss of lock on the transmitting side CDR has been detected. <Help> This alarm indicates if the Tx CDR is lo…
1.3.6.1.4.1.20044.38.2.3.3.211.1.8Columnpm1004vdcAlmTxFaultPortnread-onlycurrentLine Optical Tx Failure :This OID indicates a fault condition on the laser detected by the safety syste <Help> This alarm indicates if the laser of the line tr…
1.3.6.1.4.1.20044.38.2.3.3.211.1.9Columnpm1004vdcAlmTxNrPortnread-onlycurrentLine Optical Tx Not Ready :This OID indicates a condition has arisen leading to invalid data on the transmitting side <Help> This alarm indicates if the Tx par…
1.3.6.1.4.1.20044.38.2.3.3.211.1.15Columnpm1004vdcAlmWavelengthUnlockedPortnread-onlycurrentLine Optical Tx Wavelength Unlocked :This OID indicates that the wavelength error is exceeding the manufacturer tolerance <Help> This alarm indicates if the wa…
1.3.6.1.4.1.20044.38.2.3.3.211.1.16Columnpm1004vdcAlmTecFaultPortnread-onlycurrentLine Optical Tx Temp Regul Failed :This OID indicates a failure on the TEC module <Help> This alarm indicates if the TEC of the line transceiver is in fail con…
1.3.6.1.4.1.20044.38.2.3.3.211.1.17Columnpm1004vdcAlmApdSupplyFaultPortnread-onlycurrentLine Rx Photodiode Power Failed :This OID indicates a failure on the APD power supply <Help> This alarm indicates if the APD power supply is in fail condition …
1.3.6.1.4.1.20044.38.3Nodepm1004vdcmeasures
1.3.6.1.4.1.20044.38.3.1Nodepm1004vdcMesrOther
1.3.6.1.4.1.20044.38.3.1.0Scalarpm1004vdcMesrsynth0read-onlydeprecatedNot Used :This OID gives the unit used on AUX1 measurement of XFP#1 (Unit = )
1.3.6.1.4.1.20044.38.3.1.1Scalarpm1004vdcMesrsynth1read-onlydeprecatedNot Used :This OID gives the unit used on AUX2 measurement of XFP#1 (Unit = )
1.3.6.1.4.1.20044.38.3.2Nodepm1004vdcMesrClient
1.3.6.1.4.1.20044.38.3.2.16Tablepm1004vdcMesrtempMeasTablenot-accessiblecurrentList of pm1004vdcMesrtempMeas Article
1.3.6.1.4.1.20044.38.3.2.16.1Rowpm1004vdcMesrtempMeasEntrynot-accessiblecurrentRow definition for the pm1004vdcMesrtempMeas table
1.3.6.1.4.1.20044.38.3.2.16.1.1Columnpm1004vdcMesrtempMeasIndexread-onlycurrentIndex definition for the pm1004vdcMesrtempMeas table
1.3.6.1.4.1.20044.38.3.2.16.1.2Columnpm1004vdcMesrtempMeasPortnread-onlycurrentClient SFP Temperature :This OID gives the temperature value of the SFP plugged in port, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/25…
1.3.6.1.4.1.20044.38.3.2.24Tablepm1004vdcMesrvoltMeasTablenot-accessiblecurrentList of pm1004vdcMesrvoltMeas Article
1.3.6.1.4.1.20044.38.3.2.24.1Rowpm1004vdcMesrvoltMeasEntrynot-accessiblecurrentRow definition for the pm1004vdcMesrvoltMeas table
1.3.6.1.4.1.20044.38.3.2.24.1.1Columnpm1004vdcMesrvoltMeasIndexread-onlycurrentIndex definition for the pm1004vdcMesrvoltMeas table
1.3.6.1.4.1.20044.38.3.2.24.1.2Columnpm1004vdcMesrvoltMeasPortnread-onlycurrentClient SFP Power Supply :This OID gives the 3V3 voltage value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/100…
1.3.6.1.4.1.20044.38.3.2.32Tablepm1004vdcMesrbiasMeasTablenot-accessiblecurrentList of pm1004vdcMesrbiasMeas Article
1.3.6.1.4.1.20044.38.3.2.32.1Rowpm1004vdcMesrbiasMeasEntrynot-accessiblecurrentRow definition for the pm1004vdcMesrbiasMeas table
1.3.6.1.4.1.20044.38.3.2.32.1.1Columnpm1004vdcMesrbiasMeasIndexread-onlycurrentIndex definition for the pm1004vdcMesrbiasMeas table
1.3.6.1.4.1.20044.38.3.2.32.1.2Columnpm1004vdcMesrbiasMeasPortnread-onlycurrentClient SFP Laser Bias :This OID gives the bias value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA…
1.3.6.1.4.1.20044.38.3.2.40Tablepm1004vdcMesrtxpwrMeasTablenot-accessiblecurrentList of pm1004vdcMesrtxpwrMeas Article
1.3.6.1.4.1.20044.38.3.2.40.1Rowpm1004vdcMesrtxpwrMeasEntrynot-accessiblecurrentRow definition for the pm1004vdcMesrtxpwrMeas table
1.3.6.1.4.1.20044.38.3.2.40.1.1Columnpm1004vdcMesrtxpwrMeasIndexread-onlycurrentIndex definition for the pm1004vdcMesrtxpwrMeas table
1.3.6.1.4.1.20044.38.3.2.40.1.2Columnpm1004vdcMesrtxpwrMeasPortnread-onlycurrentClient SFP Tx Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV…
1.3.6.1.4.1.20044.38.3.2.48Tablepm1004vdcMesrrxpwrMeasTablenot-accessiblecurrentList of pm1004vdcMesrrxpwrMeas Article
1.3.6.1.4.1.20044.38.3.2.48.1Rowpm1004vdcMesrrxpwrMeasEntrynot-accessiblecurrentRow definition for the pm1004vdcMesrrxpwrMeas table
1.3.6.1.4.1.20044.38.3.2.48.1.1Columnpm1004vdcMesrrxpwrMeasIndexread-onlycurrentIndex definition for the pm1004vdcMesrrxpwrMeas table
1.3.6.1.4.1.20044.38.3.2.48.1.2Columnpm1004vdcMesrrxpwrMeasPortnread-onlycurrentClient SFP Rx Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-4…
1.3.6.1.4.1.20044.38.3.3Nodepm1004vdcMesrLine
1.3.6.1.4.1.20044.38.3.3.208Tablepm1004vdcMesrxfp1LxModTempMeasTablenot-accessiblecurrentList of pm1004vdcMesrxfp1LxModTempMeas Article
1.3.6.1.4.1.20044.38.3.3.208.1Rowpm1004vdcMesrxfp1LxModTempMeasEntrynot-accessiblecurrentRow definition for the pm1004vdcMesrxfp1LxModTempMeas table
1.3.6.1.4.1.20044.38.3.3.208.1.1Columnpm1004vdcMesrxfp1LxModTempMeasIndexread-onlycurrentIndex definition for the pm1004vdcMesrxfp1LxModTempMeas table
1.3.6.1.4.1.20044.38.3.3.208.1.2Columnpm1004vdcMesrxfp1LxModTempMeasPortnread-onlycurrentLine Optical Module Temperature :This OID gives the temperature of the XFP or OTX plugged in line#n, read from the DDM (Digital Diagnostic Monitoring) (Tempera…
1.3.6.1.4.1.20044.38.3.3.209Tablepm1004vdcMesrxfp1ReservedTablenot-accessibledeprecatedList of pm1004vdcMesrxfp1Reserved Article
1.3.6.1.4.1.20044.38.3.3.209.1Rowpm1004vdcMesrxfp1ReservedEntrynot-accessibledeprecatedRow definition for the pm1004vdcMesrxfp1Reserved table
1.3.6.1.4.1.20044.38.3.3.209.1.1Columnpm1004vdcMesrxfp1ReservedIndexread-onlydeprecatedIndex definition for the pm1004vdcMesrxfp1Reserved table
1.3.6.1.4.1.20044.38.3.3.209.1.2Columnpm1004vdcMesrxfp1ReservedPortnread-onlydeprecatedNot Used :Reserved
1.3.6.1.4.1.20044.38.3.3.210Tablepm1004vdcMesrxfp1LoBiasCurrentMeasTablenot-accessiblecurrentList of pm1004vdcMesrxfp1LoBiasCurrentMeas Article
1.3.6.1.4.1.20044.38.3.3.210.1Rowpm1004vdcMesrxfp1LoBiasCurrentMeasEntrynot-accessiblecurrentRow definition for the pm1004vdcMesrxfp1LoBiasCurrentMeas table
1.3.6.1.4.1.20044.38.3.3.210.1.1Columnpm1004vdcMesrxfp1LoBiasCurrentMeasIndexread-onlycurrentIndex definition for the pm1004vdcMesrxfp1LoBiasCurrentMeas table
1.3.6.1.4.1.20044.38.3.3.210.1.2Columnpm1004vdcMesrxfp1LoBiasCurrentMeasPortnread-onlycurrentLine Optical Module Laser Bias :This OID gives the bias value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Bias = A…
1.3.6.1.4.1.20044.38.3.3.211Tablepm1004vdcMesrxfp1LoTxPowerMeasTablenot-accessiblecurrentList of pm1004vdcMesrxfp1LoTxPowerMeas Article
1.3.6.1.4.1.20044.38.3.3.211.1Rowpm1004vdcMesrxfp1LoTxPowerMeasEntrynot-accessiblecurrentRow definition for the pm1004vdcMesrxfp1LoTxPowerMeas table
1.3.6.1.4.1.20044.38.3.3.211.1.1Columnpm1004vdcMesrxfp1LoTxPowerMeasIndexread-onlycurrentIndex definition for the pm1004vdcMesrxfp1LoTxPowerMeas table
1.3.6.1.4.1.20044.38.3.3.211.1.2Columnpm1004vdcMesrxfp1LoTxPowerMeasPortnread-onlycurrentLine Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (…
1.3.6.1.4.1.20044.38.3.3.212Tablepm1004vdcMesrxfp1LiRxPowerMeasTablenot-accessiblecurrentList of pm1004vdcMesrxfp1LiRxPowerMeas Article
1.3.6.1.4.1.20044.38.3.3.212.1Rowpm1004vdcMesrxfp1LiRxPowerMeasEntrynot-accessiblecurrentRow definition for the pm1004vdcMesrxfp1LiRxPowerMeas table
1.3.6.1.4.1.20044.38.3.3.212.1.1Columnpm1004vdcMesrxfp1LiRxPowerMeasIndexread-onlycurrentIndex definition for the pm1004vdcMesrxfp1LiRxPowerMeas table
1.3.6.1.4.1.20044.38.3.3.212.1.2Columnpm1004vdcMesrxfp1LiRxPowerMeasPortnread-onlycurrentLine Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (P…
1.3.6.1.4.1.20044.38.3.3.213Tablepm1004vdcMesrxfp1LxAux1MeasTablenot-accessibledeprecatedList of pm1004vdcMesrxfp1LxAux1Meas Article
1.3.6.1.4.1.20044.38.3.3.213.1Rowpm1004vdcMesrxfp1LxAux1MeasEntrynot-accessibledeprecatedRow definition for the pm1004vdcMesrxfp1LxAux1Meas table
1.3.6.1.4.1.20044.38.3.3.213.1.1Columnpm1004vdcMesrxfp1LxAux1MeasIndexread-onlydeprecatedIndex definition for the pm1004vdcMesrxfp1LxAux1Meas table
1.3.6.1.4.1.20044.38.3.3.213.1.2Columnpm1004vdcMesrxfp1LxAux1MeasPortnread-onlydeprecatedNot Used :This OID gives the receive power value read in the DDM (Digital Diagnostic Monitoring) of the XFP or OTX plugged in line #n (Unit = ?)
1.3.6.1.4.1.20044.38.3.3.214Tablepm1004vdcMesrxfp1LxAux2MeasTablenot-accessibledeprecatedList of pm1004vdcMesrxfp1LxAux2Meas Article
1.3.6.1.4.1.20044.38.3.3.214.1Rowpm1004vdcMesrxfp1LxAux2MeasEntrynot-accessibledeprecatedRow definition for the pm1004vdcMesrxfp1LxAux2Meas table
1.3.6.1.4.1.20044.38.3.3.214.1.1Columnpm1004vdcMesrxfp1LxAux2MeasIndexread-onlydeprecatedIndex definition for the pm1004vdcMesrxfp1LxAux2Meas table
1.3.6.1.4.1.20044.38.3.3.214.1.2Columnpm1004vdcMesrxfp1LxAux2MeasPortnread-onlydeprecatedNot Used :This OID gives the receive power value read in the DDM (Digital Diagnostic Monitoring) of the XFP or OTX plugged in line #n (Unit = ?)
1.3.6.1.4.1.20044.38.3.3.224Tablepm1004vdcMesrotx1AgingTablenot-accessiblecurrentList of pm1004vdcMesrotx1Aging Article
1.3.6.1.4.1.20044.38.3.3.224.1Rowpm1004vdcMesrotx1AgingEntrynot-accessiblecurrentRow definition for the pm1004vdcMesrotx1Aging table
1.3.6.1.4.1.20044.38.3.3.224.1.1Columnpm1004vdcMesrotx1AgingIndexread-onlycurrentIndex definition for the pm1004vdcMesrotx1Aging table
1.3.6.1.4.1.20044.38.3.3.224.1.2Columnpm1004vdcMesrotx1AgingPortnread-onlycurrentLine OTX TLH Aging :This OID gives the aging of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Aging = AV) (Unit = %) <Help> This measure…
1.3.6.1.4.1.20044.38.3.3.225Tablepm1004vdcMesrotx1LaserTemperatureTablenot-accessibledeprecatedList of pm1004vdcMesrotx1LaserTemperature Article
1.3.6.1.4.1.20044.38.3.3.225.1Rowpm1004vdcMesrotx1LaserTemperatureEntrynot-accessibledeprecatedRow definition for the pm1004vdcMesrotx1LaserTemperature table
1.3.6.1.4.1.20044.38.3.3.225.1.1Columnpm1004vdcMesrotx1LaserTemperatureIndexread-onlydeprecatedIndex definition for the pm1004vdcMesrotx1LaserTemperature table
1.3.6.1.4.1.20044.38.3.3.225.1.2Columnpm1004vdcMesrotx1LaserTemperaturePortnread-onlydeprecatedLine OTX TLH Laser Temperature :This OID gives the laser temperature of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/2…
1.3.6.1.4.1.20044.38.3.3.226Tablepm1004vdcMesrotx1FreqDeviationTablenot-accessiblecurrentList of pm1004vdcMesrotx1FreqDeviation Article
1.3.6.1.4.1.20044.38.3.3.226.1Rowpm1004vdcMesrotx1FreqDeviationEntrynot-accessiblecurrentRow definition for the pm1004vdcMesrotx1FreqDeviation table
1.3.6.1.4.1.20044.38.3.3.226.1.1Columnpm1004vdcMesrotx1FreqDeviationIndexread-onlycurrentIndex definition for the pm1004vdcMesrotx1FreqDeviation table
1.3.6.1.4.1.20044.38.3.3.226.1.2Columnpm1004vdcMesrotx1FreqDeviationPortnread-onlycurrentLine OTX TLH Frequency Deviation :This OID gives the frequency deviation of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Deviation = (A…
1.3.6.1.4.1.20044.38.3.3.227Tablepm1004vdcMesrotx1LaserWvlengthTablenot-accessiblecurrentList of pm1004vdcMesrotx1LaserWvlength Article
1.3.6.1.4.1.20044.38.3.3.227.1Rowpm1004vdcMesrotx1LaserWvlengthEntrynot-accessiblecurrentRow definition for the pm1004vdcMesrotx1LaserWvlength table
1.3.6.1.4.1.20044.38.3.3.227.1.1Columnpm1004vdcMesrotx1LaserWvlengthIndexread-onlycurrentIndex definition for the pm1004vdcMesrotx1LaserWvlength table
1.3.6.1.4.1.20044.38.3.3.227.1.2Columnpm1004vdcMesrotx1LaserWvlengthPortnread-onlycurrentLine Optical Module Wavelength :This OID gives the laser wavelength of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Wavelength=29979245…
1.3.6.1.4.1.20044.38.4Nodepm1004vdccounters
1.3.6.1.4.1.20044.38.4.1Nodepm1004vdcCntOther
1.3.6.1.4.1.20044.38.4.2Nodepm1004vdcCntClient
1.3.6.1.4.1.20044.38.4.3Nodepm1004vdcCntLine
1.3.6.1.4.1.20044.38.4.3.152Tablepm1004vdcCntdfrmB1ErrCntTablenot-accessiblecurrentList of pm1004vdcCntdfrmB1ErrCnt Article
1.3.6.1.4.1.20044.38.4.3.152.1Rowpm1004vdcCntdfrmB1ErrCntEntrynot-accessiblecurrentRow definition for the pm1004vdcCntdfrmB1ErrCnt table
1.3.6.1.4.1.20044.38.4.3.152.1.1Columnpm1004vdcCntdfrmB1ErrCntIndexread-onlycurrentIndex definition for the pm1004vdcCntdfrmB1ErrCnt table
1.3.6.1.4.1.20044.38.4.3.152.1.2Columnpm1004vdcCntdfrmB1ErrCntValuePortnread-onlycurrentLine Input SM-BIP8 Errors :This counter is incremented each time a B1 error is detected on the Deframer input stream. <Help> This counter gives the number of B…
1.3.6.1.4.1.20044.38.4.3.152.1.3Columnpm1004vdcCntdfrmB1ErrCntErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the B1 error counter value is invalid on Port
1.3.6.1.4.1.20044.38.4.3.152.1.4Columnpm1004vdcCntdfrmB1ErrCntOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a B1 error counter overload on Port
1.3.6.1.4.1.20044.38.4.3.153Tablepm1004vdcCntdfrmTimCntTablenot-accessiblecurrentList of pm1004vdcCntdfrmTimCnt Article
1.3.6.1.4.1.20044.38.4.3.153.1Rowpm1004vdcCntdfrmTimCntEntrynot-accessiblecurrentRow definition for the pm1004vdcCntdfrmTimCnt table
1.3.6.1.4.1.20044.38.4.3.153.1.1Columnpm1004vdcCntdfrmTimCntIndexread-onlycurrentIndex definition for the pm1004vdcCntdfrmTimCnt table
1.3.6.1.4.1.20044.38.4.3.153.1.2Columnpm1004vdcCntdfrmTimCntValuePortnread-onlycurrentLine Timer Counter :This is the timing counter dedicated to the downstream deframer counters. It is incremented every 125 us.
1.3.6.1.4.1.20044.38.4.3.153.1.3Columnpm1004vdcCntdfrmTimCntErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.38.4.3.153.1.4Columnpm1004vdcCntdfrmTimCntOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.38.4.259Scalarpm1004vdcCntCountersResetread-writecurrentCounters Reset:This OID resets and restarts all the counters
1.3.6.1.4.1.20044.38.4.260Scalarpm1004vdcCntCountersStopread-writecurrentCounters stop:This OID stops all the counters
1.3.6.1.4.1.20044.38.6Nodepm1004vdccontrolsWrite
1.3.6.1.4.1.20044.38.6.1Nodepm1004vdcCtrlOther
1.3.6.1.4.1.20044.38.6.1.1Nodepm1004vdcCtrlconfMgnt1
1.3.6.1.4.1.20044.38.6.1.1.1Scalarpm1004vdcCtrlConf1Load1read-writecurrentLoad Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM.
1.3.6.1.4.1.20044.38.6.1.1.2Scalarpm1004vdcCtrlConf2Load1read-writecurrentLoad Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM.
1.3.6.1.4.1.20044.38.6.1.1.10Scalarpm1004vdcCtrlConf2Flash1read-writecurrentWrite Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura…
1.3.6.1.4.1.20044.38.6.1.1.14Scalarpm1004vdcCtrlConf2Clear1read-writecurrentClear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o…
1.3.6.1.4.1.20044.38.6.1.4Nodepm1004vdcCtrlsynth4
1.3.6.1.4.1.20044.38.6.1.4.1Scalarpm1004vdcCtrlCorrelatOnread-writecurrentEnable Alarm Correlation :This OID enables the alarm correlation in the PM.
1.3.6.1.4.1.20044.38.6.1.4.2Scalarpm1004vdcCtrlCorrelatOffread-writecurrentDisable Alarm Correlation :This OID disables the alarm correlation in the PM.
1.3.6.1.4.1.20044.38.6.1.5Nodepm1004vdcCtrlswMgnt
1.3.6.1.4.1.20044.38.6.1.5.2Scalarpm1004vdcCtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> …
1.3.6.1.4.1.20044.38.6.1.5.3Scalarpm1004vdcCtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th…
1.3.6.1.4.1.20044.38.6.1.5.5Scalarpm1004vdcCtrlLoadSwBank1read-writecurrentSet Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW…
1.3.6.1.4.1.20044.38.6.1.5.6Scalarpm1004vdcCtrlLoadSwBank2read-writecurrentSet Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S…
1.3.6.1.4.1.20044.38.6.1.6Nodepm1004vdcCtrlgwMgnt
1.3.6.1.4.1.20044.38.6.1.6.1Scalarpm1004vdcCtrlCurrentGwResetread-writecurrentActive Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting.
1.3.6.1.4.1.20044.38.6.1.6.5Scalarpm1004vdcCtrlLoadGwBank1read-writecurrentSet Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.38.6.1.6.6Scalarpm1004vdcCtrlLoadGwBank2read-writecurrentSet Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.38.6.1.6.7Scalarpm1004vdcCtrlLoadGwBank3read-writecurrentSet Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.38.6.1.6.8Scalarpm1004vdcCtrlLoadGwBank4read-writecurrentSet Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.38.6.1.192Nodepm1004vdcCtrlledTest
1.3.6.1.4.1.20044.38.6.1.192.1Scalarpm1004vdcCtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.38.6.1.192.2Scalarpm1004vdcCtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.38.6.1.192.3Scalarpm1004vdcCtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.38.6.1.193Nodepm1004vdcCtrlmoduleOosMode
1.3.6.1.4.1.20044.38.6.1.193.1Scalarpm1004vdcCtrlModuleOosModeread-writecurrentPM Out Of Service :This OID sets the PM Out Of Service <Help> This control defines the service state of the complete module
1.3.6.1.4.1.20044.38.6.1.197Nodepm1004vdcCtrlmaintenanceMode
1.3.6.1.4.1.20044.38.6.1.197.1Scalarpm1004vdcCtrlMaintenanceModeread-writecurrentEnable Maintenance :This OID enables the maintenance mode on the PM. <Help> This control enables the maintenance mode on the PM.
1.3.6.1.4.1.20044.38.6.2Nodepm1004vdcCtrlClient
1.3.6.1.4.1.20044.38.6.2.16Tablepm1004vdcCtrlaccessLoopTablenot-accessiblecurrentList of pm1004vdcCtrlaccessLoop Article
1.3.6.1.4.1.20044.38.6.2.16.1Rowpm1004vdcCtrlaccessLoopEntrynot-accessiblecurrentRow definition for the pm1004vdcCtrlaccessLoop table
1.3.6.1.4.1.20044.38.6.2.16.1.1Columnpm1004vdcCtrlaccessLoopIndexread-onlycurrentIndex definition for the pm1004vdcCtrlaccessLoop table
1.3.6.1.4.1.20044.38.6.2.16.1.2Columnpm1004vdcCtrlaccessLoopPortnread-writecurrentClient Facility Loopback :This OID operates a Client Facility Loopback, looping client input signal on the client output port. The loop is located on the clien…
1.3.6.1.4.1.20044.38.6.2.18Tablepm1004vdcCtrlportOosModeTablenot-accessiblecurrentList of pm1004vdcCtrlportOosMode Article
1.3.6.1.4.1.20044.38.6.2.18.1Rowpm1004vdcCtrlportOosModeEntrynot-accessiblecurrentRow definition for the pm1004vdcCtrlportOosMode table
1.3.6.1.4.1.20044.38.6.2.18.1.1Columnpm1004vdcCtrlportOosModeIndexread-onlycurrentIndex definition for the pm1004vdcCtrlportOosMode table
1.3.6.1.4.1.20044.38.6.2.18.1.2Columnpm1004vdcCtrlportOosModePortnread-writecurrentClient Out Of Service :This OID sets the Service state of the client port (In Service, Tx Out of Service, Rx Out of Service or Port (Rx and Tx) Out of Service)…
1.3.6.1.4.1.20044.38.6.2.20Tablepm1004vdcCtrlsfpOffCtrlTablenot-accessiblecurrentList of pm1004vdcCtrlsfpOffCtrl Article
1.3.6.1.4.1.20044.38.6.2.20.1Rowpm1004vdcCtrlsfpOffCtrlEntrynot-accessiblecurrentRow definition for the pm1004vdcCtrlsfpOffCtrl table
1.3.6.1.4.1.20044.38.6.2.20.1.1Columnpm1004vdcCtrlsfpOffCtrlIndexread-onlycurrentIndex definition for the pm1004vdcCtrlsfpOffCtrl table
1.3.6.1.4.1.20044.38.6.2.20.1.2Columnpm1004vdcCtrlsfpOffCtrlPortnread-writecurrentSignal OFF :This OID switches off the SFP. <Help> This control defines the laser state of the client transceiver
1.3.6.1.4.1.20044.38.6.2.21Tablepm1004vdcCtrlcsfUpInsTablenot-accessiblecurrentList of pm1004vdcCtrlcsfUpIns Article
1.3.6.1.4.1.20044.38.6.2.21.1Rowpm1004vdcCtrlcsfUpInsEntrynot-accessiblecurrentRow definition for the pm1004vdcCtrlcsfUpIns table
1.3.6.1.4.1.20044.38.6.2.21.1.1Columnpm1004vdcCtrlcsfUpInsIndexread-onlycurrentIndex definition for the pm1004vdcCtrlcsfUpIns table
1.3.6.1.4.1.20044.38.6.2.21.1.2Columnpm1004vdcCtrlcsfUpInsPortnread-writecurrentClient Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo…
1.3.6.1.4.1.20044.38.6.2.22Tablepm1004vdcCtrlcaisDwInsTablenot-accessiblecurrentList of pm1004vdcCtrlcaisDwIns Article
1.3.6.1.4.1.20044.38.6.2.22.1Rowpm1004vdcCtrlcaisDwInsEntrynot-accessiblecurrentRow definition for the pm1004vdcCtrlcaisDwIns table
1.3.6.1.4.1.20044.38.6.2.22.1.1Columnpm1004vdcCtrlcaisDwInsIndexread-onlycurrentIndex definition for the pm1004vdcCtrlcaisDwIns table
1.3.6.1.4.1.20044.38.6.2.22.1.2Columnpm1004vdcCtrlcaisDwInsPortnread-writecurrentClient AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port
1.3.6.1.4.1.20044.38.6.2.26Tablepm1004vdcCtrlclientAccessTermLoopTablenot-accessiblecurrentList of pm1004vdcCtrlclientAccessTermLoop Article
1.3.6.1.4.1.20044.38.6.2.26.1Rowpm1004vdcCtrlclientAccessTermLoopEntrynot-accessiblecurrentRow definition for the pm1004vdcCtrlclientAccessTermLoop table
1.3.6.1.4.1.20044.38.6.2.26.1.1Columnpm1004vdcCtrlclientAccessTermLoopIndexread-onlycurrentIndex definition for the pm1004vdcCtrlclientAccessTermLoop table
1.3.6.1.4.1.20044.38.6.2.26.1.2Columnpm1004vdcCtrlclientAccessTermLoopPortnread-writecurrentClient Terminal Loopback :This OID operates a Client Terminal Loopback, looping client input signal on the client output port. The loop is located on the line …
1.3.6.1.4.1.20044.38.6.2.43Tablepm1004vdcCtrlrxVideoProtocolTablenot-accessiblecurrentList of pm1004vdcCtrlrxVideoProtocol Article
1.3.6.1.4.1.20044.38.6.2.43.1Rowpm1004vdcCtrlrxVideoProtocolEntrynot-accessiblecurrentRow definition for the pm1004vdcCtrlrxVideoProtocol table
1.3.6.1.4.1.20044.38.6.2.43.1.1Columnpm1004vdcCtrlrxVideoProtocolIndexread-onlycurrentIndex definition for the pm1004vdcCtrlrxVideoProtocol table
1.3.6.1.4.1.20044.38.6.2.43.1.2Columnpm1004vdcCtrlrxVideoProtocolPortnread-writecurrentForce DVB ASI On RX Side :This OID selects the DVB ASI protocol on the client port and disable the auto-sensing feature <Help> This control selects the DVB ASI…
1.3.6.1.4.1.20044.38.6.2.128Tablepm1004vdcCtrladddropClientRxProtectTablenot-accessiblecurrentList of pm1004vdcCtrladddropClientRxProtect Article
1.3.6.1.4.1.20044.38.6.2.128.1Rowpm1004vdcCtrladddropClientRxProtectEntrynot-accessiblecurrentRow definition for the pm1004vdcCtrladddropClientRxProtect table
1.3.6.1.4.1.20044.38.6.2.128.1.1Columnpm1004vdcCtrladddropClientRxProtectIndexread-onlycurrentIndex definition for the pm1004vdcCtrladddropClientRxProtect table
1.3.6.1.4.1.20044.38.6.2.128.1.2Columnpm1004vdcCtrladddropClientRxProtectPortnread-writecurrentClient Switch Mode :This bit selects the manual (1) or automatic (0) switch method <Help> This control defines the protection switch mode on the client interfa…
1.3.6.1.4.1.20044.38.6.2.136Tablepm1004vdcCtrladddropTsClientModeTablenot-accessiblecurrentList of pm1004vdcCtrladddropTsClientMode Article
1.3.6.1.4.1.20044.38.6.2.136.1Rowpm1004vdcCtrladddropTsClientModeEntrynot-accessiblecurrentRow definition for the pm1004vdcCtrladddropTsClientMode table
1.3.6.1.4.1.20044.38.6.2.136.1.1Columnpm1004vdcCtrladddropTsClientModeIndexread-onlycurrentIndex definition for the pm1004vdcCtrladddropTsClientMode table
1.3.6.1.4.1.20044.38.6.2.136.1.2Columnpm1004vdcCtrladddropTsClientModePortnread-writecurrentClient Mode :This OID selects the mode on the client <Help> This control defines the mode (Add/Drop or Split&Select) of the Client
1.3.6.1.4.1.20044.38.6.3Nodepm1004vdcCtrlLine
1.3.6.1.4.1.20044.38.6.3.64Nodepm1004vdcCtrlcommAccessLoop
1.3.6.1.4.1.20044.38.6.3.64.1Scalarpm1004vdcCtrlCommAccessloopread-writedeprecatedPM Full Access Loop Mode :This OID, when set, puts the module in common access loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.
1.3.6.1.4.1.20044.38.6.3.66Nodepm1004vdcCtrllineLoop
1.3.6.1.4.1.20044.38.6.3.66.1Scalarpm1004vdcCtrlLineLoopread-writedeprecatedPM Line Loop Mode :This OID, when set at '1' puts the module in line loopback mode, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. The Ups…
1.3.6.1.4.1.20044.38.6.3.73Nodepm1004vdcCtrlProtMgnt
1.3.6.1.4.1.20044.38.6.3.73.1Scalarpm1004vdcCtrlLineNumberread-writecurrentActive Line Number : This OID sets the active line number
1.3.6.1.4.1.20044.38.6.3.73.2Scalarpm1004vdcCtrlProtModeread-writecurrentLine Switch Mode (Auto Or Manual) :This bit selects the manual (1) or automatic (0) switch method <Help> This control defines the protection switch mode on the…
1.3.6.1.4.1.20044.38.6.3.74Tablepm1004vdcCtrllineOosModeTablenot-accessiblecurrentList of pm1004vdcCtrllineOosMode Article
1.3.6.1.4.1.20044.38.6.3.74.1Rowpm1004vdcCtrllineOosModeEntrynot-accessiblecurrentRow definition for the pm1004vdcCtrllineOosMode table
1.3.6.1.4.1.20044.38.6.3.74.1.1Columnpm1004vdcCtrllineOosModeIndexread-onlycurrentIndex definition for the pm1004vdcCtrllineOosMode table
1.3.6.1.4.1.20044.38.6.3.74.1.2Columnpm1004vdcCtrllineOosModePortnread-writecurrentLine Out Of Service (!Laser OFF!) :This OID sets the line port Out Of Service <Help> This control defines the service state of the line port
1.3.6.1.4.1.20044.38.6.3.198Tablepm1004vdcCtrldccEnableTablenot-accessiblecurrentList of pm1004vdcCtrldccEnable Article
1.3.6.1.4.1.20044.38.6.3.198.1Rowpm1004vdcCtrldccEnableEntrynot-accessiblecurrentRow definition for the pm1004vdcCtrldccEnable table
1.3.6.1.4.1.20044.38.6.3.198.1.1Columnpm1004vdcCtrldccEnableIndexread-onlycurrentIndex definition for the pm1004vdcCtrldccEnable table
1.3.6.1.4.1.20044.38.6.3.198.1.2Columnpm1004vdcCtrldccEnablePortnread-writecurrentDCC Mode : This OID enables the DCC mode on the PM <Help> This control enables the DCC mode on the PM
1.3.6.1.4.1.20044.38.6.3.208Tablepm1004vdcCtrlxfpOnoffTablenot-accessiblecurrentList of pm1004vdcCtrlxfpOnoff Article
1.3.6.1.4.1.20044.38.6.3.208.1Rowpm1004vdcCtrlxfpOnoffEntrynot-accessiblecurrentRow definition for the pm1004vdcCtrlxfpOnoff table
1.3.6.1.4.1.20044.38.6.3.208.1.1Columnpm1004vdcCtrlxfpOnoffIndexread-onlycurrentIndex definition for the pm1004vdcCtrlxfpOnoff table
1.3.6.1.4.1.20044.38.6.3.208.1.2Columnpm1004vdcCtrlxfpOnoffPortnread-writecurrentXFP/OTX Optical Laser OFF :This OID switches off the XFP or the OTX <Help> This control defines the laser state of the line transceiver
1.3.6.1.4.1.20044.38.6.3.209Tablepm1004vdcCtrlxfpLineLoopTablenot-accessiblecurrentList of pm1004vdcCtrlxfpLineLoop Article
1.3.6.1.4.1.20044.38.6.3.209.1Rowpm1004vdcCtrlxfpLineLoopEntrynot-accessiblecurrentRow definition for the pm1004vdcCtrlxfpLineLoop table
1.3.6.1.4.1.20044.38.6.3.209.1.1Columnpm1004vdcCtrlxfpLineLoopIndexread-onlycurrentIndex definition for the pm1004vdcCtrlxfpLineLoop table
1.3.6.1.4.1.20044.38.6.3.209.1.2Columnpm1004vdcCtrlxfpLineLoopPortnread-writecurrentLine Facility Loopback :This OID operates a Line Facility Loopback, looping line input signal on the line output port. The loop is located on the line transcei…
1.3.6.1.4.1.20044.38.6.3.210Tablepm1004vdcCtrlxfpXfiLoopTablenot-accessiblecurrentList of pm1004vdcCtrlxfpXfiLoop Article
1.3.6.1.4.1.20044.38.6.3.210.1Rowpm1004vdcCtrlxfpXfiLoopEntrynot-accessiblecurrentRow definition for the pm1004vdcCtrlxfpXfiLoop table
1.3.6.1.4.1.20044.38.6.3.210.1.1Columnpm1004vdcCtrlxfpXfiLoopIndexread-onlycurrentIndex definition for the pm1004vdcCtrlxfpXfiLoop table
1.3.6.1.4.1.20044.38.6.3.210.1.2Columnpm1004vdcCtrlxfpXfiLoopPortnread-writecurrentLine Terminal Loopback :This OID operates a Line Terminal Loopback, looping line input signal on the line output port. The loop is located on all client transc…
1.3.6.1.4.1.20044.38.7Nodepm1004vdcri
1.3.6.1.4.1.20044.38.7.1Nodepm1004vdcriTable
1.3.6.1.4.1.20044.38.7.1.1Tablepm1004vdcRinvSfpTablenot-accessiblecurrentList of the SFPs on the selected module
1.3.6.1.4.1.20044.38.7.1.1.1Rowpm1004vdcRinvSfpEntrynot-accessiblecurrentRow definition for the SFP table
1.3.6.1.4.1.20044.38.7.1.1.1.1Columnpm1004vdcRinvSfpIndexread-onlycurrentIndex for SFP table
1.3.6.1.4.1.20044.38.7.1.1.1.2Columnpm1004vdcRinvsfpread-onlycurrentInventory for the SFP: This OID contains the inventory for the SFP
1.3.6.1.4.1.20044.38.7.1.2Tablepm1004vdcRinvLineTablenot-accessiblecurrentList of the XFPs on the selected module
1.3.6.1.4.1.20044.38.7.1.2.1Rowpm1004vdcRinvLineEntrynot-accessiblecurrentRow definition for the XFP table
1.3.6.1.4.1.20044.38.7.1.2.1.1Columnpm1004vdcRinvLineIndexread-onlycurrentIndex for XFP table
1.3.6.1.4.1.20044.38.7.1.2.1.2Columnpm1004vdcRinvxfpLineread-onlycurrentInventory for the XFP: This OID contains the inventory for the XFP
1.3.6.1.4.1.20044.38.7.2Scalarpm1004vdcRinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.38.7.3Scalarpm1004vdcRinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.38.7.4Scalarpm1004vdcRinvModulePlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.38.7.5Scalarpm1004vdcRinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.38.7.6Scalarpm1004vdcRinvGwPlatformread-onlycurrentGW platform desciption: This OID contains the description of the Gateware platform.
1.3.6.1.4.1.20044.38.8Nodepm1004vdcdownload
1.3.6.1.4.1.20044.38.8.1Nodepm1004vdcDwlOther
1.3.6.1.4.1.20044.38.8.1.0Nodepm1004vdcDwlrestartProcess
1.3.6.1.4.1.20044.38.8.1.0.1Scalarpm1004vdcDwlWarmRestartProcessedread-onlycurrentWarm Restart :This OID indicates that the module last restart was a Warm RESTART
1.3.6.1.4.1.20044.38.8.1.0.2Scalarpm1004vdcDwlColdRestartProcessedread-onlycurrentCold Restart :This OID indicates that the module last restart was a Cold RESTART
1.3.6.1.4.1.20044.38.8.1.1Nodepm1004vdcDwlswBanksUsed
1.3.6.1.4.1.20044.38.8.1.1.1Scalarpm1004vdcDwlSwBank1Usedread-onlycurrentSW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby
1.3.6.1.4.1.20044.38.8.1.1.2Scalarpm1004vdcDwlSwBank2Usedread-onlycurrentSW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby
1.3.6.1.4.1.20044.38.8.1.1.5Scalarpm1004vdcDwlSwBank1Notemptyread-onlycurrentSW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package
1.3.6.1.4.1.20044.38.8.1.1.6Scalarpm1004vdcDwlSwBank2Notemptyread-onlycurrentSW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package
1.3.6.1.4.1.20044.38.8.1.2Nodepm1004vdcDwlgwBanksUsed
1.3.6.1.4.1.20044.38.8.1.2.1Scalarpm1004vdcDwlGwBank1Usedread-onlycurrentGW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby
1.3.6.1.4.1.20044.38.8.1.2.2Scalarpm1004vdcDwlGwBank2Usedread-onlycurrentGW bank 2 active :This OID indicates the module is working on GW bank 2
1.3.6.1.4.1.20044.38.8.1.2.3Scalarpm1004vdcDwlGwBank3Usedread-onlycurrentGW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby
1.3.6.1.4.1.20044.38.8.1.2.4Scalarpm1004vdcDwlGwBank4Usedread-onlycurrentGW bank 4 active :This OID indicates the module is working on GW bank 4
1.3.6.1.4.1.20044.38.8.1.2.5Scalarpm1004vdcDwlGwBank1Notemptyread-onlycurrentGW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package
1.3.6.1.4.1.20044.38.8.1.2.6Scalarpm1004vdcDwlGwBank2Notemptyread-onlycurrentGW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2
1.3.6.1.4.1.20044.38.8.1.2.7Scalarpm1004vdcDwlGwBank3Notemptyread-onlycurrentGW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package
1.3.6.1.4.1.20044.38.8.1.2.8Scalarpm1004vdcDwlGwBank4Notemptyread-onlycurrentGW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4
1.3.6.1.4.1.20044.38.8.2Nodepm1004vdcDwlClient
1.3.6.1.4.1.20044.38.8.3Nodepm1004vdcDwlLine
1.3.6.1.4.1.20044.38.9Nodepm1004vdcConfig
1.3.6.1.4.1.20044.38.9.1Nodepm1004vdcCfgAccessCAisCsf
1.3.6.1.4.1.20044.38.9.1.1Tablepm1004vdcCfgClientcaiscsfTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.38.9.1.1.1Rowpm1004vdcCfgClientcaiscsfEntrynot-accessiblecurrentRow definition for the accessCAisCsf table
1.3.6.1.4.1.20044.38.9.1.1.1.1Columnpm1004vdcCfgClientcaiscsfIndexread-onlycurrentIndex definition for the clientcaiscsf table
1.3.6.1.4.1.20044.38.9.1.1.1.3Columnpm1004vdcCfgCAisModePortnread-writecurrentCAIS mode on Client Port :This register enables/disables port laser shutdown on CAIS insertion condition
1.3.6.1.4.1.20044.38.9.1.1.1.9Columnpm1004vdcCfgUpAccessioAlmPortnread-writecurrentCSF contributors on Client Port :This register configures the contributors to upstream CSF insertion on the port.
1.3.6.1.4.1.20044.38.9.1.1.1.10Columnpm1004vdcCfgUpMapperDeAlmPortnread-writecurrentCSF contributors on Client Port :This register configures the contributors to upstream CSF insertion on the port.
1.3.6.1.4.1.20044.38.9.1.1.1.17Columnpm1004vdcCfgDownAccessioAlmPortnread-writecurrentCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port.
1.3.6.1.4.1.20044.38.9.1.1.1.18Columnpm1004vdcCfgDownMapperDeAlmPortnread-writecurrentCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port.
1.3.6.1.4.1.20044.38.9.1.1.1.19Columnpm1004vdcCfgDownDfrmAlmPortnread-writecurrentCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port.
1.3.6.1.4.1.20044.38.9.1.1.1.20Columnpm1004vdcCfgDownLineSyncAlarmsPortnread-writedeprecatedCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port.
1.3.6.1.4.1.20044.38.9.2Nodepm1004vdcCfgStartup
1.3.6.1.4.1.20044.38.9.2.1Tablepm1004vdcCfgClientStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.38.9.2.1.1Rowpm1004vdcCfgClientStartupEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.38.9.2.1.1.1Columnpm1004vdcCfgClientStartupIndexread-onlycurrentIndex definition for the clientStartup table
1.3.6.1.4.1.20044.38.9.2.1.1.3Columnpm1004vdcCfgSystConfPortPortnread-writecurrentDefault Settings on Client Port :This register configures the default initialisation settings on the port.
1.3.6.1.4.1.20044.38.9.2.1.1.4Columnpm1004vdcCfgNetConfPortPortnread-writecurrentDefault Protocol on Client Port :This register configures the default initialisation protocol on the port.
1.3.6.1.4.1.20044.38.9.2.1.1.5Columnpm1004vdcCfgAdddropConfPortPortnread-writedeprecatedDefault Add&Drop mode on Client Port :This register configures the default Add&Drop mode on the port.
1.3.6.1.4.1.20044.38.9.2.2Nodepm1004vdctablelineStartup
1.3.6.1.4.1.20044.38.9.2.2.2Scalarpm1004vdcCfgsystConfLine1read-writecurrentDefault Settings on Line 1 :This register configures the default initialisation settings on Line port 1.
1.3.6.1.4.1.20044.38.9.2.2.5Scalarpm1004vdcCfglineOptions1read-writecurrentDefault Options on Active Line Port :This register configures the default options on the active line port
1.3.6.1.4.1.20044.38.9.2.2.6Scalarpm1004vdcCfgsystConfLine2read-writecurrentDefault Settings on Line 2 :This register configures the default initialisation settings on Line port 2.
1.3.6.1.4.1.20044.38.9.2.2.7Scalarpm1004vdcCfglineSelectionread-writecurrentDefault Settings of active line :This register configures the start up active line.
1.3.6.1.4.1.20044.38.9.2.2.9Scalarpm1004vdcCfglineOptions2read-writecurrentDefault Options on Active Line Port :This register configures the default options on the active line port
1.3.6.1.4.1.20044.38.9.2.3Tablepm1004vdcCfgXfpTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.38.9.2.3.1Rowpm1004vdcCfgXfpEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.38.9.2.3.1.1Columnpm1004vdcCfgXfpIndexread-onlycurrentIndex definition for the xfp table
1.3.6.1.4.1.20044.38.9.2.3.1.3Columnpm1004vdcCfgSystConfXfpPortnread-writecurrentDefault settings on XFP Port :This register configures the default initialisation settings on XFP port.
1.3.6.1.4.1.20044.38.9.2.3.1.4Columnpm1004vdcCfgDataRateConfXfpPortnread-writedeprecated:
1.3.6.1.4.1.20044.38.9.3Nodepm1004vdcCfgLabels
1.3.6.1.4.1.20044.38.9.3.1Tablepm1004vdcCfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.38.9.3.1.1Rowpm1004vdcCfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.38.9.3.1.1.1Columnpm1004vdcCfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.38.9.3.1.1.3Columnpm1004vdcCfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.38.9.3.2Tablepm1004vdcCfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.38.9.3.2.1Rowpm1004vdcCfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.38.9.3.2.1.1Columnpm1004vdcCfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.38.9.3.2.1.3Columnpm1004vdcCfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.38.9.4Nodepm1004vdcCfgStartupthresholds
1.3.6.1.4.1.20044.38.9.4.1Tablepm1004vdcCfgClientStartupThreshTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.38.9.4.1.1Rowpm1004vdcCfgClientStartupThreshEntrynot-accessiblecurrentRow definition for the startupthresholds table
1.3.6.1.4.1.20044.38.9.4.1.1.1Columnpm1004vdcCfgClientStartupThreshIndexread-onlycurrentIndex definition for the clientStartupThresh table
1.3.6.1.4.1.20044.38.9.4.1.1.15Columnpm1004vdcCfgClientThreshtxpowhighPortnread-writecurrentDefault Setting on Tx Power high threshold :This register configures the default initialisation of the high threshold of the Transmit power on the port.
1.3.6.1.4.1.20044.38.9.4.1.1.16Columnpm1004vdcCfgClientThreshtxpowlowPortnread-writecurrentDefault Setting on Tx Power low threshold :This register configures the default initialisation of the low threshold of the Transmit power on the port.
1.3.6.1.4.1.20044.38.9.4.1.1.19Columnpm1004vdcCfgClientThreshrxpowhighPortnread-writecurrentDefault Setting on Rx Power high threshold :This register configures the default initialisation of the high threshold of the received power on the port.
1.3.6.1.4.1.20044.38.9.4.1.1.20Columnpm1004vdcCfgClientThreshrxpowlowPortnread-writecurrentDefault Setting on Rx Power low threshold :This register configures the default initialisation of the low threshold of the received power on the port.
1.3.6.1.4.1.20044.38.9.4.2Tablepm1004vdcCfgLineStartupThreshTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.38.9.4.2.1Rowpm1004vdcCfgLineStartupThreshEntrynot-accessiblecurrentRow definition for the startupthresholds table
1.3.6.1.4.1.20044.38.9.4.2.1.1Columnpm1004vdcCfgLineStartupThreshIndexread-onlycurrentIndex definition for the lineStartupThresh table
1.3.6.1.4.1.20044.38.9.4.2.1.15Columnpm1004vdcCfgLineThreshtxpowhighPortnread-writecurrentDefault Setting on Tx Power high threshold :This register configures the default initialisation of the high threshold of the Transmit power on the line.
1.3.6.1.4.1.20044.38.9.4.2.1.16Columnpm1004vdcCfgLineThreshtxpowlowPortnread-writecurrentDefault Setting on Tx Power low threshold :This register configures the default initialisation of the low threshold of the Transmit power on the line.
1.3.6.1.4.1.20044.38.9.4.2.1.19Columnpm1004vdcCfgLineThreshrxpowhighPortnread-writecurrentDefault Setting on Rx Power high threshold :This register configures the default initialisation of the high threshold of the received power on the line.
1.3.6.1.4.1.20044.38.9.4.2.1.20Columnpm1004vdcCfgLineThreshrxpowlowPortnread-writecurrentDefault Setting on Rx Power low threshold :This register configures the default initialisation of the low threshold of the received power on the line.
1.3.6.1.4.1.20044.38.9.5Nodepm1004vdcCfgStartuptlh
1.3.6.1.4.1.20044.38.9.5.1Tablepm1004vdcCfgOtxtlhTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.38.9.5.1.1Rowpm1004vdcCfgOtxtlhEntrynot-accessiblecurrentRow definition for the startuptlh table
1.3.6.1.4.1.20044.38.9.5.1.1.1Columnpm1004vdcCfgOtxtlhIndexread-onlycurrentIndex definition for the otxtlh table
1.3.6.1.4.1.20044.38.9.5.1.1.3Columnpm1004vdcCfgNuPortnread-writedeprecated:
1.3.6.1.4.1.20044.38.9.5.1.1.4Columnpm1004vdcCfgLineDitherRatePortnread-writecurrentDefault Line OTX TLH FM amplitude :This register configures the start-up width of the frequency modulation of the Line OTX TLH
1.3.6.1.4.1.20044.38.9.5.1.1.5Columnpm1004vdcCfgLineDitherFhzPortnread-writecurrentDefault Line OTX TLH FM frequency :This register configures the start-up frequency of the frequency modulation of the Line OTX TLH
1.3.6.1.4.1.20044.38.9.5.1.1.6Columnpm1004vdcCfgLinePwrLaserPortnread-writecurrentDefaut Line OTX TLH output Power :This register configures the start-up output power of the Line OTX TLH (Unit = dBm)
1.3.6.1.4.1.20044.38.9.5.1.1.7Columnpm1004vdcCfgLineFCurrentPortnread-writecurrentDefault Line OTX TLH Channel :This register configures the start-up laser channel of the Line OTX TLH
1.3.6.1.4.1.20044.38.9.5.1.1.8Columnpm1004vdcCfgLineGridCurrentPortnread-writecurrentDefault Line OTX TLH Grid :This register configures the start-up laser grid of the Line OTX TLH
1.3.6.1.4.1.20044.38.9.5.1.1.9Columnpm1004vdcCfgFPortnread-writecurrentDefault Line OTX TLH lowest Freq :This register configures the start-up lowest frequency supported on the Line OTX TLH
1.3.6.1.4.1.20044.38.9.5.1.1.10Columnpm1004vdcCfgReservedPortnread-writedeprecated:
1.3.6.1.4.1.20044.38.9.5.1.1.11Columnpm1004vdcCfgLinePhotodiodeModePortnread-writecurrentDefault Line OTX TLH APD mode :This register configures the start-up APD mode of the Line OTX TLH
1.3.6.1.4.1.20044.38.9.5.1.1.12Columnpm1004vdcCfgLinePhotodiodeValuePortnread-writecurrentDefault Line OTX TLH APD atten. :This register configures the start-up APD attenuation on the Line OTX TLH
1.3.6.1.4.1.20044.38.9.6Nodepm1004vdcCfgStartupslotslineaddtx1
1.3.6.1.4.1.20044.38.9.6.1Tablepm1004vdcCfgSlotslineaddtx1Tablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.38.9.6.1.1Rowpm1004vdcCfgSlotslineaddtx1Entrynot-accessiblecurrentRow definition for the startupslotslineaddtx1 table
1.3.6.1.4.1.20044.38.9.6.1.1.1Columnpm1004vdcCfgSlotslineaddtx1Indexread-onlycurrentIndex definition for the slotslineaddtx1 table
1.3.6.1.4.1.20044.38.9.6.1.1.3Columnpm1004vdcCfgLine1Addslotb2PortPortnread-writecurrentPort Defaut Add Slot allocation (MSB) on Line1 :This register configures the start-up slots allocation on the port (MSB)
1.3.6.1.4.1.20044.38.9.6.1.1.4Columnpm1004vdcCfgLine1Addslotb1PortPortnread-writecurrentPort Defaut Add Slot allocation (LSB) on Line1 :This register configures the start-up slots allocation on the port (LSB)
1.3.6.1.4.1.20044.38.9.6.1.1.5Columnpm1004vdcCfgLine1AddprotocolPortPortnread-writecurrentPort Defaut Protocol on Line1 :This register configures the start-up protocol on the port
1.3.6.1.4.1.20044.38.9.7Nodepm1004vdcCfgStartupslotslineaddtx2
1.3.6.1.4.1.20044.38.9.7.1Tablepm1004vdcCfgSlotslineaddtx2Tablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.38.9.7.1.1Rowpm1004vdcCfgSlotslineaddtx2Entrynot-accessiblecurrentRow definition for the startupslotslineaddtx2 table
1.3.6.1.4.1.20044.38.9.7.1.1.1Columnpm1004vdcCfgSlotslineaddtx2Indexread-onlycurrentIndex definition for the slotslineaddtx2 table
1.3.6.1.4.1.20044.38.9.7.1.1.3Columnpm1004vdcCfgLine2Addslotb2PortPortnread-writecurrentPort Defaut Add Slot allocation (MSB) on Line2 :This register configures the start-up slots allocation on the port (MSB)
1.3.6.1.4.1.20044.38.9.7.1.1.4Columnpm1004vdcCfgLine2Addslotb1PortPortnread-writecurrentPort Defaut Add Slot allocation (LSB) on Line2 :This register configures the start-up slots allocation on the port (LSB)
1.3.6.1.4.1.20044.38.9.7.1.1.5Columnpm1004vdcCfgLine2AddprotocolPortPortnread-writecurrentPort Defaut Protocol on Line2 :This register configures the start-up protocol on the port
1.3.6.1.4.1.20044.38.9.8Nodepm1004vdcCfgStartupslotslinepassthroughtx1
1.3.6.1.4.1.20044.38.9.8.1Tablepm1004vdcCfgSlotslinepassthroughtx1Tablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.38.9.8.1.1Rowpm1004vdcCfgSlotslinepassthroughtx1Entrynot-accessiblecurrentRow definition for the startupslotslinepassthroughtx1 table
1.3.6.1.4.1.20044.38.9.8.1.1.1Columnpm1004vdcCfgSlotslinepassthroughtx1Indexread-onlycurrentIndex definition for the slotslinepassthroughtx1 table
1.3.6.1.4.1.20044.38.9.8.1.1.3Columnpm1004vdcCfgLine1Slotb2PassthroughPortnread-writecurrentPort Defaut PassThrough Slot allocation (MSB) on Line1 :This register configures the start-up slots allocation on the port (MSB)
1.3.6.1.4.1.20044.38.9.8.1.1.4Columnpm1004vdcCfgLine1Slotb1PassthroughPortnread-writecurrentPort Defaut PassThrough Slot allocation (LSB) on Line1 :This register configures the start-up slots allocation on the port (LSB)
1.3.6.1.4.1.20044.38.9.8.1.1.5Columnpm1004vdcCfgLine1ProtocolPassthroughPortnread-writecurrentPort Defaut PassThrough Protocol on Line1 :This register configures the start-up protocol on the port
1.3.6.1.4.1.20044.38.9.9Nodepm1004vdcCfgStartupslotslinepassthroughtx2
1.3.6.1.4.1.20044.38.9.9.1Tablepm1004vdcCfgSlotslinepassthroughtx2Tablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.38.9.9.1.1Rowpm1004vdcCfgSlotslinepassthroughtx2Entrynot-accessiblecurrentRow definition for the startupslotslinepassthroughtx2 table
1.3.6.1.4.1.20044.38.9.9.1.1.1Columnpm1004vdcCfgSlotslinepassthroughtx2Indexread-onlycurrentIndex definition for the slotslinepassthroughtx2 table
1.3.6.1.4.1.20044.38.9.9.1.1.3Columnpm1004vdcCfgLine2Slotb2PassthroughPortnread-writecurrentPort Defaut PassThrough Slot allocation (MSB) on Line2 :This register configures the start-up slots allocation on the port (MSB)
1.3.6.1.4.1.20044.38.9.9.1.1.4Columnpm1004vdcCfgLine2Slotb1PassthroughPortnread-writecurrentPort Defaut PassThrough Slot allocation (LSB) on Line2 :This register configures the start-up slots allocation on the port (LSB)
1.3.6.1.4.1.20044.38.9.9.1.1.5Columnpm1004vdcCfgLine2ProtocolPassthroughPortnread-writecurrentPort Defaut PassThrough Protocol on Line2 :This register configures the start-up protocol on the port
1.3.6.1.4.1.20044.38.9.10Nodepm1004vdcCfgStartupslotslinedroprx1
1.3.6.1.4.1.20044.38.9.10.1Tablepm1004vdcCfgSlotslinedroprx1Tablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.38.9.10.1.1Rowpm1004vdcCfgSlotslinedroprx1Entrynot-accessiblecurrentRow definition for the startupslotslinedroprx1 table
1.3.6.1.4.1.20044.38.9.10.1.1.1Columnpm1004vdcCfgSlotslinedroprx1Indexread-onlycurrentIndex definition for the slotslinedroprx1 table
1.3.6.1.4.1.20044.38.9.10.1.1.3Columnpm1004vdcCfgLine1Dropslotb2PortPortnread-writecurrentPort Defaut Drop Slot allocation (MSB) on Line1 :This register configures the start-up slots allocation on the port (MSB)
1.3.6.1.4.1.20044.38.9.10.1.1.4Columnpm1004vdcCfgLine1Dropslotb1PortPortnread-writecurrentPort Defaut Drop Slot allocation (LSB) on Line1 :This register configures the start-up slots allocation on the port (LSB)
1.3.6.1.4.1.20044.38.9.10.1.1.5Columnpm1004vdcCfgLine1DropprotocolPortPortnread-writecurrentPort Defaut Protocol on Line1 :This register configures the start-up protocol on the port
1.3.6.1.4.1.20044.38.9.11Nodepm1004vdcCfgStartupslotslineaddrx2
1.3.6.1.4.1.20044.38.9.11.1Tablepm1004vdcCfgSlotslinedroprx2Tablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.38.9.11.1.1Rowpm1004vdcCfgSlotslinedroprx2Entrynot-accessiblecurrentRow definition for the startupslotslineaddrx2 table
1.3.6.1.4.1.20044.38.9.11.1.1.1Columnpm1004vdcCfgSlotslinedroprx2Indexread-onlycurrentIndex definition for the slotslinedroprx2 table
1.3.6.1.4.1.20044.38.9.11.1.1.3Columnpm1004vdcCfgLine2Dropslotb2PortPortnread-writecurrentPort Defaut Drop Slot allocation (MSB) on Line2 :This register configures the start-up slots allocation on the port (MSB)
1.3.6.1.4.1.20044.38.9.11.1.1.4Columnpm1004vdcCfgLine2Dropslotb1PortPortnread-writecurrentPort Defaut Drop Slot allocation (LSB) on Line2 :This register configures the start-up slots allocation on the port (LSB)
1.3.6.1.4.1.20044.38.9.11.1.1.5Columnpm1004vdcCfgLine2DropprotocolPortPortnread-writecurrentPort Defaut Protocol on Line2 :This register configures the start-up protocol on the port
1.3.6.1.4.1.20044.38.9.12Nodepm1004vdcCfgOther
1.3.6.1.4.1.20044.38.9.12.1Nodepm1004vdctablemoduleOther
1.3.6.1.4.1.20044.38.9.12.1.2Scalarpm1004vdcCfgmoderead-writecurrentDefault settings on Module :This register selects the startup mode of the module
1.3.6.1.4.1.20044.38.9.13Nodepm1004vdcCfgStartuptablefive
1.3.6.1.4.1.20044.38.9.13.1Tablepm1004vdcCfgOtxtlhcapabilitiesTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.38.9.13.1.1Rowpm1004vdcCfgOtxtlhcapabilitiesEntrynot-accessiblecurrentRow definition for the startuptablefive table
1.3.6.1.4.1.20044.38.9.13.1.1.1Columnpm1004vdcCfgOtxtlhcapabilitiesIndexread-onlycurrentIndex definition for the otxtlhcapabilities table
1.3.6.1.4.1.20044.38.9.13.1.1.3Columnpm1004vdcCfgComponentTypePortnread-onlycurrentComponent parameters :This OID defines the component parameters
1.3.6.1.4.1.20044.38.9.13.1.1.4Columnpm1004vdcCfgMiscellaneousPortnread-onlycurrentMiscellaneous default settings :This OID defines the miscellaneous parameters
1.3.6.1.4.1.20044.38.9.13.1.1.5Columnpm1004vdcCfgFirstChannelPortnread-onlycurrentNumber of the first channel of the component :This OID defines the first channel number of the PM
1.3.6.1.4.1.20044.38.9.13.1.1.6Columnpm1004vdcCfgLastChannelPortnread-onlycurrentNumber of the last channel of the component :This OID defines the last channel number of the PM
1.3.6.1.4.1.20044.38.9.13.1.1.7Columnpm1004vdcCfgGridPortnread-onlycurrentGrid value of the component :This OID defines the grid of the PM
1.3.6.1.4.1.20044.38.9.257Scalarpm1004vdcCfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.38.10Nodepm1004vdctraps
1.3.6.1.4.1.20044.38.10.2Scalarpm1004vdctrapPortNumberread-onlycurrentLast port which generates a trap
1.3.6.1.4.1.20044.38.10.3Scalarpm1004vdctrapLineNumberread-onlycurrentLast Line which generates a trap
1.3.6.1.4.1.20044.38.10.4Scalarpm1004vdctrapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.38.10.30Notificationpm1004vdcLineTrapNotUrgentGoesOncurrentNot urgent Line default is activated
1.3.6.1.4.1.20044.38.10.31Notificationpm1004vdcLineTrapNotUrgentGoesOffcurrentNot urgent Line default disappeared
1.3.6.1.4.1.20044.38.10.32Notificationpm1004vdcLineTrapUrgentGoesOncurrentUrgent Line default is activated
1.3.6.1.4.1.20044.38.10.33Notificationpm1004vdcLineTrapUrgentGoesOffcurrentUrgent Line default disappeared
1.3.6.1.4.1.20044.38.10.34Notificationpm1004vdcLineTrapCritGoesOncurrentCritical Line default is activated
1.3.6.1.4.1.20044.38.10.35Notificationpm1004vdcLineTrapCritGoesOffcurrentCritical Line default disappeared
1.3.6.1.4.1.20044.38.10.40Notificationpm1004vdcClientTrapNotUrgentGoesOncurrentNot urgent client default is activated
1.3.6.1.4.1.20044.38.10.41Notificationpm1004vdcClientTrapNotUrgentGoesOffcurrentNot urgent client default disappeared
1.3.6.1.4.1.20044.38.10.42Notificationpm1004vdcClientTrapUrgentGoesOncurrentUrgent client default is activated
1.3.6.1.4.1.20044.38.10.43Notificationpm1004vdcClientTrapUrgentGoesOffcurrentUrgent client default disappeared
1.3.6.1.4.1.20044.38.10.44Notificationpm1004vdcClientTrapCritGoesOncurrentCritical client default is activated
1.3.6.1.4.1.20044.38.10.45Notificationpm1004vdcClientTrapCritGoesOffcurrentCritical client default disappeared
1.3.6.1.4.1.20044.38.10.50Notificationpm1004vdcPowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.38.10.51Notificationpm1004vdcPowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared
1.3.6.1.4.1.20044.38.11Nodepm1004vdcMonitoring
1.3.6.1.4.1.20044.38.11.1Nodepm1004vdcMonOther
1.3.6.1.4.1.20044.38.11.1.3Nodepm1004vdcMonRmon
1.3.6.1.4.1.20044.38.11.1.3.359Scalarpm1004vdcMonCountersResetread-writecurrentRMON Counters Reset:This OID resets and restarts all the RMON counters
1.3.6.1.4.1.20044.38.11.1.3.360Scalarpm1004vdcMonCountersStopread-writecurrentRMON Counters stop:This OID stops all the RMON counters
1.3.6.1.4.1.20044.38.11.2Nodepm1004vdcMonClient
1.3.6.1.4.1.20044.38.11.2.4Nodepm1004vdcMonClientRmonCounter
1.3.6.1.4.1.20044.38.11.2.4.16Tablepm1004vdcMonupRmonByteCntTablenot-accessiblecurrentList of pm1004vdcMonupRmonByteCnt Article
1.3.6.1.4.1.20044.38.11.2.4.16.1Rowpm1004vdcMonupRmonByteCntEntrynot-accessiblecurrentRow definition for the pm1004vdcMonupRmonByteCnt table
1.3.6.1.4.1.20044.38.11.2.4.16.1.1Columnpm1004vdcMonupRmonByteCntIndexread-onlycurrentIndex definition for the pm1004vdcMonupRmonByteCnt table
1.3.6.1.4.1.20044.38.11.2.4.16.1.2Columnpm1004vdcMonupRmonByteCntValuePortnread-onlycurrentClient Input Bytes :This counter is increased each time a data byte is received on the client port <Help> This counter gives the number of bytes received on th…
1.3.6.1.4.1.20044.38.11.2.4.16.1.3Columnpm1004vdcMonupRmonByteCntErrorPortnread-onlycurrentBytes Counter Error :This OID when set indicates the Bytes counter value is invalid on clinet port
1.3.6.1.4.1.20044.38.11.2.4.16.1.4Columnpm1004vdcMonupRmonByteCntOverloadPortnread-onlycurrentBytes Counter Overload :This OID when set indicates a Bytes counter overload on client port
1.3.6.1.4.1.20044.38.11.2.4.24Tablepm1004vdcMonupRmonCrcErrorCntTablenot-accessiblecurrentList of pm1004vdcMonupRmonCrcErrorCnt Article
1.3.6.1.4.1.20044.38.11.2.4.24.1Rowpm1004vdcMonupRmonCrcErrorCntEntrynot-accessiblecurrentRow definition for the pm1004vdcMonupRmonCrcErrorCnt table
1.3.6.1.4.1.20044.38.11.2.4.24.1.1Columnpm1004vdcMonupRmonCrcErrorCntIndexread-onlycurrentIndex definition for the pm1004vdcMonupRmonCrcErrorCnt table
1.3.6.1.4.1.20044.38.11.2.4.24.1.2Columnpm1004vdcMonupRmonCrcErrorCntValuePortnread-onlycurrentClient Input CRC Errors :This counter is increased each time a CRC error is detected on the client port <Help> This counter gives the number of CRC Errors rece…
1.3.6.1.4.1.20044.38.11.2.4.24.1.3Columnpm1004vdcMonupRmonCrcErrorCntErrorPortnread-onlycurrentCRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on clinet port
1.3.6.1.4.1.20044.38.11.2.4.24.1.4Columnpm1004vdcMonupRmonCrcErrorCntOverloadPortnread-onlycurrentCRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on client port
1.3.6.1.4.1.20044.38.11.2.4.32Tablepm1004vdcMonupRmonPacketsCntTablenot-accessiblecurrentList of pm1004vdcMonupRmonPacketsCnt Article
1.3.6.1.4.1.20044.38.11.2.4.32.1Rowpm1004vdcMonupRmonPacketsCntEntrynot-accessiblecurrentRow definition for the pm1004vdcMonupRmonPacketsCnt table
1.3.6.1.4.1.20044.38.11.2.4.32.1.1Columnpm1004vdcMonupRmonPacketsCntIndexread-onlycurrentIndex definition for the pm1004vdcMonupRmonPacketsCnt table
1.3.6.1.4.1.20044.38.11.2.4.32.1.2Columnpm1004vdcMonupRmonPacketsCntValuePortnread-onlycurrentClient Input Packets :This counter is increased each time a packet is received on the client port <Help> This counter gives the number of packets received on t…
1.3.6.1.4.1.20044.38.11.2.4.32.1.3Columnpm1004vdcMonupRmonPacketsCntErrorPortnread-onlycurrentPackets Counter Error :This OID when set indicates the Packets counter value is invalid on clinet port
1.3.6.1.4.1.20044.38.11.2.4.32.1.4Columnpm1004vdcMonupRmonPacketsCntOverloadPortnread-onlycurrentPackets Counter Overload :This OID when set indicates a Packets counter overload on client port
1.3.6.1.4.1.20044.38.11.2.4.40Tablepm1004vdcMonupRmonBroadcastCntTablenot-accessiblecurrentList of pm1004vdcMonupRmonBroadcastCnt Article
1.3.6.1.4.1.20044.38.11.2.4.40.1Rowpm1004vdcMonupRmonBroadcastCntEntrynot-accessiblecurrentRow definition for the pm1004vdcMonupRmonBroadcastCnt table
1.3.6.1.4.1.20044.38.11.2.4.40.1.1Columnpm1004vdcMonupRmonBroadcastCntIndexread-onlycurrentIndex definition for the pm1004vdcMonupRmonBroadcastCnt table
1.3.6.1.4.1.20044.38.11.2.4.40.1.2Columnpm1004vdcMonupRmonBroadcastCntValuePortnread-onlycurrentClient Input Broadcast Packets :This counter is increased each time a broadcast packet is received on the client port <Help> This counter gives the number of B…
1.3.6.1.4.1.20044.38.11.2.4.40.1.3Columnpm1004vdcMonupRmonBroadcastCntErrorPortnread-onlycurrentBroadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on clinet port
1.3.6.1.4.1.20044.38.11.2.4.40.1.4Columnpm1004vdcMonupRmonBroadcastCntOverloadPortnread-onlycurrentBroadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port
1.3.6.1.4.1.20044.38.11.2.4.48Tablepm1004vdcMonupRmonMulticastCntTablenot-accessiblecurrentList of pm1004vdcMonupRmonMulticastCnt Article
1.3.6.1.4.1.20044.38.11.2.4.48.1Rowpm1004vdcMonupRmonMulticastCntEntrynot-accessiblecurrentRow definition for the pm1004vdcMonupRmonMulticastCnt table
1.3.6.1.4.1.20044.38.11.2.4.48.1.1Columnpm1004vdcMonupRmonMulticastCntIndexread-onlycurrentIndex definition for the pm1004vdcMonupRmonMulticastCnt table
1.3.6.1.4.1.20044.38.11.2.4.48.1.2Columnpm1004vdcMonupRmonMulticastCntValuePortnread-onlycurrentClient Input Multicast Packets :This counter is increased each time a Multicast packet is received on the client port <Help> This counter gives the number of M…
1.3.6.1.4.1.20044.38.11.2.4.48.1.3Columnpm1004vdcMonupRmonMulticastCntErrorPortnread-onlycurrentMulticast Counter Error :This OID when set indicates the Multicast counter value is invalid on clinet port
1.3.6.1.4.1.20044.38.11.2.4.48.1.4Columnpm1004vdcMonupRmonMulticastCntOverloadPortnread-onlycurrentMulticast Counter Overload :This OID when set indicates a Multicast counter overload on client port
1.3.6.1.4.1.20044.38.11.2.4.208Tablepm1004vdcMonupLineRmonByteCntTablenot-accessiblecurrentList of pm1004vdcMonupLineRmonByteCnt Article
1.3.6.1.4.1.20044.38.11.2.4.208.1Rowpm1004vdcMonupLineRmonByteCntEntrynot-accessiblecurrentRow definition for the pm1004vdcMonupLineRmonByteCnt table
1.3.6.1.4.1.20044.38.11.2.4.208.1.1Columnpm1004vdcMonupLineRmonByteCntIndexread-onlycurrentIndex definition for the pm1004vdcMonupLineRmonByteCnt table
1.3.6.1.4.1.20044.38.11.2.4.208.1.2Columnpm1004vdcMonupLineRmonByteCntValuePortnread-onlycurrentLine Input Bytes :This counter is increased each time a data byte is received on the Line port <Help> This counter gives the number of bytes received on the Li…
1.3.6.1.4.1.20044.38.11.2.4.208.1.3Columnpm1004vdcMonupLineRmonByteCntErrorPortnread-onlycurrentBytes Counter Error :This OID when set indicates the Bytes counter value is invalid on line port
1.3.6.1.4.1.20044.38.11.2.4.208.1.4Columnpm1004vdcMonupLineRmonByteCntOverloadPortnread-onlycurrentBytes Counter Overload :This OID when set indicates a Bytes counter overload on line port
1.3.6.1.4.1.20044.38.11.2.4.209Tablepm1004vdcMonupLineRmonCrcErrorCntTablenot-accessiblecurrentList of pm1004vdcMonupLineRmonCrcErrorCnt Article
1.3.6.1.4.1.20044.38.11.2.4.209.1Rowpm1004vdcMonupLineRmonCrcErrorCntEntrynot-accessiblecurrentRow definition for the pm1004vdcMonupLineRmonCrcErrorCnt table
1.3.6.1.4.1.20044.38.11.2.4.209.1.1Columnpm1004vdcMonupLineRmonCrcErrorCntIndexread-onlycurrentIndex definition for the pm1004vdcMonupLineRmonCrcErrorCnt table
1.3.6.1.4.1.20044.38.11.2.4.209.1.2Columnpm1004vdcMonupLineRmonCrcErrorCntValuePortnread-onlycurrentLine Input CRC Errors :This counter is increased each time a CRC error is detected on the Line port <Help> This counter gives the number of CRC Errors received…
1.3.6.1.4.1.20044.38.11.2.4.209.1.3Columnpm1004vdcMonupLineRmonCrcErrorCntErrorPortnread-onlycurrentCRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on line port
1.3.6.1.4.1.20044.38.11.2.4.209.1.4Columnpm1004vdcMonupLineRmonCrcErrorCntOverloadPortnread-onlycurrentCRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on line port
1.3.6.1.4.1.20044.38.11.2.4.210Tablepm1004vdcMonupLineRmonPacketsCntTablenot-accessiblecurrentList of pm1004vdcMonupLineRmonPacketsCnt Article
1.3.6.1.4.1.20044.38.11.2.4.210.1Rowpm1004vdcMonupLineRmonPacketsCntEntrynot-accessiblecurrentRow definition for the pm1004vdcMonupLineRmonPacketsCnt table
1.3.6.1.4.1.20044.38.11.2.4.210.1.1Columnpm1004vdcMonupLineRmonPacketsCntIndexread-onlycurrentIndex definition for the pm1004vdcMonupLineRmonPacketsCnt table
1.3.6.1.4.1.20044.38.11.2.4.210.1.2Columnpm1004vdcMonupLineRmonPacketsCntValuePortnread-onlycurrentLine Input Packets :This counter is increased each time a packet is received on the Line port <Help> This counter gives the number of packets received on the L…
1.3.6.1.4.1.20044.38.11.2.4.210.1.3Columnpm1004vdcMonupLineRmonPacketsCntErrorPortnread-onlycurrentPackets Counter Error :This OID when set indicates the Packets counter value is invalid on client port
1.3.6.1.4.1.20044.38.11.2.4.210.1.4Columnpm1004vdcMonupLineRmonPacketsCntOverloadPortnread-onlycurrentPackets Counter Overload :This OID when set indicates a Packets counter overload on line port
1.3.6.1.4.1.20044.38.11.3Nodepm1004vdcMonLine
1.3.6.1.4.1.20044.38.11.3.4Nodepm1004vdcMonLineRmonCounter
Type Definitions
NameSyntaxStatusDescription
Pm1004vdcAdjustValueINTEGER { otxadjustvalue0(0), otxadjustvalue1(1), otxadjustvalue2(2), otxadjustvalue3(3), otxadjustvalue4(4), otxadjustvalue5(5), otxadjustvalue6(6), otxadjustvalue7(7), otxadjustvalue8(8), otxadjustvalue9(9), otxadjustvalue10(10) }currentDifferent values in Adjust mode on OTX-TLH on client and line ports
Pm1004vdcClientOosModeINTEGER { clientportis(0), clienttxoos(1), clientrxoos(2), clientportoos(3) }currentMode for OOS on client ports
Pm1004vdcDccModeINTEGER { dccNo(0), dcctermLine1(1), dcctermLine2(2), dcctermLines12(3), dccmaster(4), dccslaveLine12(7) }currentMode for DCC
Pm1004vdcModeAddDropINTEGER { singleSplitSelect(256) }currentdifferent mode for client
Pm1004vdcModeTimeSlotINTEGER { singleSplitSelect(256) }currentdifferent mode for time slot
Pm1004vdcOtxChannelINTEGERcurrentChannel selection on OTX-TLH on client and line ports
Pm1004vdcOtxGridINTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50) }currentDifferent grids on OTX-TLH on client and line ports
Pm1004vdcOtxModeINTEGER { otx80mode(1), otx60mode(2), otxadjustmode(4) }currentDifferent modes on OTX-TLH on client and line ports
Pm1004vdcProtectionStartUpINTEGER { auto(2), manualX2Line2(0), manualX1Line1(1) }currentprotection for startup
Pm1004vdcProtectionTimeSlotINTEGER { auto(0), manualX2Line2(257), manualX1Line1(513) }currentprotection for control