EKINOPS-Pm1004VDC-MIB
656 objects
MIB for managing Ekinops modules with PM1004vdc software
Imported Objects
| EKINOPS-MIB | EkiApiState EkiMeasureType EkiMode ekinops EkiOnOff EkiProtocol EkiState EkiSynchroMode |
| SNMPv2-SMI | Counter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20044.38 | IdentitymodulePm1004vdc | MIB for managing Ekinops modules with PM1004vdc software | ||
| 1.3.6.1.4.1.20044.38.2 | Nodepm1004vdcalarms | |||
| 1.3.6.1.4.1.20044.38.2.1 | Nodepm1004vdcAlmOther | |||
| 1.3.6.1.4.1.20044.38.2.1.1 | Nodepm1004vdcAlmOtherNurg | |||
| 1.3.6.1.4.1.20044.38.2.1.1.2 | Nodepm1004vdcAlmsynthAlm2 | |||
| 1.3.6.1.4.1.20044.38.2.1.1.2.1 | Scalarpm1004vdcAlmConfTableSave | read-only | current | PM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> other… |
| 1.3.6.1.4.1.20044.38.2.1.1.2.2 | Scalarpm1004vdcAlmInvUpload | read-only | current | Inventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> other (1) <Alarmtype> other (1) <Polarit… |
| 1.3.6.1.4.1.20044.38.2.1.1.2.3 | Scalarpm1004vdcAlmConfTableLoad | read-only | current | PM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> other (1) <Alarmt… |
| 1.3.6.1.4.1.20044.38.2.1.1.2.4 | Scalarpm1004vdcAlmCorrelatOff | read-only | current | Not Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> other (1) <Alarmtype> other (1) <Pol… |
| 1.3.6.1.4.1.20044.38.2.1.1.2.5 | Scalarpm1004vdcAlmMaintenanceOn | read-only | current | Maintenance Mode :This OID indicates that the PM is in maintenance mode. <Help> This alarm indicates that the maintenance mode is enabled on the PM <Condtype> … |
| 1.3.6.1.4.1.20044.38.2.1.2 | Nodepm1004vdcAlmOtherUrg | |||
| 1.3.6.1.4.1.20044.38.2.1.2.194 | Nodepm1004vdcAlmmodInitFailLevel2 | |||
| 1.3.6.1.4.1.20044.38.2.1.2.194.1 | Scalarpm1004vdcAlmLedFail | read-only | current | Led Fail :This OID indicates that Led register has not been correctly initalized <Help> This alarm indicates if the module LEDs are correctly initialized <Cond… |
| 1.3.6.1.4.1.20044.38.2.1.2.194.2 | Scalarpm1004vdcAlmNextColdBootForced | read-only | current | Next Cold Boot Forced :This OID indicates that the next Reset will be forced Cold <Help> This alarm indicates that the next reset of the module will be forced … |
| 1.3.6.1.4.1.20044.38.2.1.2.194.3 | Scalarpm1004vdcAlmBootUndone | read-only | current | Boot Undone :This OID indicates that the boot has not been correctly achieved <Help> This alarm indicates if the module has correctly boot <Condtype> BOOT_UNDO… |
| 1.3.6.1.4.1.20044.38.2.1.2.194.4 | Scalarpm1004vdcAlmResetHwInitFail | read-only | current | Reset HW Init Fail :This OID indicates that the HW intialization has caused unknown intial conditions <Help> This alarm indicates if the HW has been correctly … |
| 1.3.6.1.4.1.20044.38.2.1.2.194.5 | Scalarpm1004vdcAlmSwInitFail | read-only | current | SW Init Fail :This OID indicates that the SW intialization has caused unknown intial conditions <Help> This alarm indicates if the SW module is correctly initi… |
| 1.3.6.1.4.1.20044.38.2.1.2.195 | Nodepm1004vdcAlmmodInitFailLevel3 | |||
| 1.3.6.1.4.1.20044.38.2.1.2.195.1 | Scalarpm1004vdcAlmGwIdentFail | read-only | current | GW Ident Fail :This OID indicates that GW identification has not been read <Help> This alarm indicates if the GW has been correctly identified <Condtype> GW_ID… |
| 1.3.6.1.4.1.20044.38.2.1.2.195.2 | Scalarpm1004vdcAlmObmTypeReadFail | read-only | current | OBM Type Read Fail :This OID indicates that OBM type has not been recognized <Help> This alarm indicates if the OBM board has been correctly identified <Condty… |
| 1.3.6.1.4.1.20044.38.2.1.2.195.3 | Scalarpm1004vdcAlmInitModuleFail | read-only | current | Init Module Fail :This OID indicates that the Module has not been correctly initialized <Help> This alarm indicates if the SW module is correctly initialized <… |
| 1.3.6.1.4.1.20044.38.2.1.2.195.5 | Scalarpm1004vdcAlmXfp1InitFail | read-only | current | XFP1 Init Fail :This OID indicates that the XFP has not been correctly initialized <Help> This alarm indicates if the line transceiver 1 is correctly initializ… |
| 1.3.6.1.4.1.20044.38.2.1.2.195.6 | Scalarpm1004vdcAlmXfp2InitFail | read-only | current | XFP2 Init Fail :This OID indicates that the XFP has not been correctly initialized <Help> This alarm indicates if the line transceiver 2 is correctly initializ… |
| 1.3.6.1.4.1.20044.38.2.1.2.195.7 | Scalarpm1004vdcAlmLine1InitFail | read-only | current | Line1 Init Fail :This OID indicates that the Line registersvsubset has not been correctly initialized <Help> This alarm indicates if the line port 1 is correct… |
| 1.3.6.1.4.1.20044.38.2.1.2.195.8 | Scalarpm1004vdcAlmLine2InitFail | read-only | current | Line2 Init Fail :This OID indicates that the Line register subset has not been correctly initialized <Help> This alarm indicates if the line port 2 is correctl… |
| 1.3.6.1.4.1.20044.38.2.1.2.195.9 | Scalarpm1004vdcAlmClient1InitFail | read-only | current | Client1 Init Fail :This OID indicates that Client 1 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 1 is cor… |
| 1.3.6.1.4.1.20044.38.2.1.2.195.10 | Scalarpm1004vdcAlmClient2InitFail | read-only | current | Client2 Init Fail :This OID indicates that Client 2 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 2 is cor… |
| 1.3.6.1.4.1.20044.38.2.1.2.195.11 | Scalarpm1004vdcAlmClient3InitFail | read-only | current | Client3 Init Fail :This OID indicates that Client 3 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 3 is cor… |
| 1.3.6.1.4.1.20044.38.2.1.2.195.12 | Scalarpm1004vdcAlmClient4InitFail | read-only | current | Client4 Init Fail :This OID indicates that Client 4 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 4 is cor… |
| 1.3.6.1.4.1.20044.38.2.1.2.195.13 | Scalarpm1004vdcAlmClient5InitFail | read-only | current | Client5 Init Fail :This OID indicates that Client 5 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 5 is cor… |
| 1.3.6.1.4.1.20044.38.2.1.2.195.14 | Scalarpm1004vdcAlmClient6InitFail | read-only | current | Client6 Init Fail :This OID indicates that Client 6 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 6 is cor… |
| 1.3.6.1.4.1.20044.38.2.1.2.198 | Nodepm1004vdcAlmclientRxProt | |||
| 1.3.6.1.4.1.20044.38.2.1.2.198.1 | Scalarpm1004vdcAlmAdddropClient1West | read-only | current | Client West Rx Side Active :This OID indicates the Client is active on West receiving side <Condtype> ADDDROP_CLIENT1_WEST <Probcause> other (1) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.38.2.1.2.198.2 | Scalarpm1004vdcAlmAdddropClient2West | read-only | current | Client West Rx Side Active :This OID indicates the Client is active on West receiving side <Condtype> ADDDROP_CLIENT2_WEST <Probcause> other (1) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.38.2.1.2.198.3 | Scalarpm1004vdcAlmAdddropClient3West | read-only | current | Client West Rx Side Active :This OID indicates the Client is active on West receiving side <Condtype> ADDDROP_CLIENT3_WEST <Probcause> other (1) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.38.2.1.2.198.4 | Scalarpm1004vdcAlmAdddropClient4West | read-only | current | Client West Rx Side Active :This OID indicates the Client is active on West receiving side <Condtype> ADDDROP_CLIENT4_WEST <Probcause> other (1) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.38.2.1.2.198.5 | Scalarpm1004vdcAlmAdddropClient5West | read-only | current | Client West Rx Side Active :This OID indicates the Client is active on West receiving side <Condtype> ADDDROP_CLIENT5_WEST <Probcause> other (1) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.38.2.1.2.198.6 | Scalarpm1004vdcAlmAdddropClient6West | read-only | current | Client West Rx Side Active :This OID indicates the Client is active on West receiving side <Condtype> ADDDROP_CLIENT6_WEST <Probcause> other (1) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.38.2.1.2.198.9 | Scalarpm1004vdcAlmAdddropClient1East | read-only | current | Client East Rx Side Active :This OID indicates the Client is active on East receiving side <Condtype> ADDDROP_CLIENT1_EAST <Probcause> other (1) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.38.2.1.2.198.10 | Scalarpm1004vdcAlmAdddropClient2East | read-only | current | Client East Rx Side Active :This OID indicates the Client is active on East receiving side <Condtype> ADDDROP_CLIENT2_EAST <Probcause> other (1) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.38.2.1.2.198.11 | Scalarpm1004vdcAlmAdddropClient3East | read-only | current | Client East Rx Side Active :This OID indicates the Client is active on East receiving side <Condtype> ADDDROP_CLIENT3_EAST <Probcause> other (1) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.38.2.1.2.198.12 | Scalarpm1004vdcAlmAdddropClient4East | read-only | current | Client East Rx Side Active :This OID indicates the Client is active on East receiving side <Condtype> ADDDROP_CLIENT4_EAST <Probcause> other (1) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.38.2.1.2.198.13 | Scalarpm1004vdcAlmAdddropClient5East | read-only | current | Client East Rx Side Active :This OID indicates the Client is active on East receiving side <Condtype> ADDDROP_CLIENT5_EAST <Probcause> other (1) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.38.2.1.2.198.14 | Scalarpm1004vdcAlmAdddropClient6East | read-only | current | Client East Rx Side Active :This OID indicates the Client is active on East receiving side <Condtype> ADDDROP_CLIENT6_EAST <Probcause> other (1) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.38.2.1.3 | Nodepm1004vdcAlmOtherCrit | |||
| 1.3.6.1.4.1.20044.38.2.1.3.0 | Nodepm1004vdcAlmsynthAlm0 | |||
| 1.3.6.1.4.1.20044.38.2.1.3.0.9 | Scalarpm1004vdcAlmModGlobFail | read-only | current | Module Failure :This OID is set on detection of a failure originating from the PM <Condtype> MOD_GLOB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> sy… |
| 1.3.6.1.4.1.20044.38.2.1.3.0.15 | Scalarpm1004vdcAlmDefFuseA | read-only | current | Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.38.2.1.3.0.16 | Scalarpm1004vdcAlmDefFuseB | read-only | current | Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.38.2.2 | Nodepm1004vdcAlmClient | |||
| 1.3.6.1.4.1.20044.38.2.2.1 | Nodepm1004vdcAlmClientNurg | |||
| 1.3.6.1.4.1.20044.38.2.2.1.48 | Tablepm1004vdcAlmsfpWarnDdmTable | not-accessible | current | List of pm1004vdcAlmsfpWarnDdm Article |
| 1.3.6.1.4.1.20044.38.2.2.1.48.1 | Rowpm1004vdcAlmsfpWarnDdmEntry | not-accessible | current | Row definition for the pm1004vdcAlmsfpWarnDdm table |
| 1.3.6.1.4.1.20044.38.2.2.1.48.1.1 | Columnpm1004vdcAlmsfpWarnDdmIndex | read-only | current | Index definition for the pm1004vdcAlmsfpWarnDdm table |
| 1.3.6.1.4.1.20044.38.2.2.1.48.1.2 | Columnpm1004vdcAlmTxPwLowWngPortn | read-only | current | Client SFP Tx Power Low Warning :Warning indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> TX… |
| 1.3.6.1.4.1.20044.38.2.2.1.48.1.3 | Columnpm1004vdcAlmTxPwrHighWngPortn | read-only | current | Client SFP Tx Power High Warning :Warning indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> … |
| 1.3.6.1.4.1.20044.38.2.2.1.48.1.4 | Columnpm1004vdcAlmTxBiasLowWngPortn | read-only | current | Client SFP Bias Low Warning :Warning indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> … |
| 1.3.6.1.4.1.20044.38.2.2.1.48.1.5 | Columnpm1004vdcAlmTxBiasHighWngPortn | read-only | current | Client SFP Bias High Warning :Warning indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype… |
| 1.3.6.1.4.1.20044.38.2.2.1.48.1.6 | Columnpm1004vdcAlmVccLowWngPortn | read-only | current | Client SFP Power Supply Low Warning :Warning indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype… |
| 1.3.6.1.4.1.20044.38.2.2.1.48.1.7 | Columnpm1004vdcAlmVccHighWngPortn | read-only | current | Client SFP Power Supply High Warning :Warning indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condty… |
| 1.3.6.1.4.1.20044.38.2.2.1.48.1.8 | Columnpm1004vdcAlmTempLowWngPortn | read-only | current | Client SFP Temp Low Warning :Warning indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> TEMP_LO… |
| 1.3.6.1.4.1.20044.38.2.2.1.48.1.9 | Columnpm1004vdcAlmTempHighWngPortn | read-only | current | Client SFP Temp High Warning :Warning indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> TEMP_… |
| 1.3.6.1.4.1.20044.38.2.2.1.48.1.16 | Columnpm1004vdcAlmRxPwrLowWngPortn | read-only | current | Client SFP Rx Power Low Warning :Warning indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> RX_… |
| 1.3.6.1.4.1.20044.38.2.2.1.48.1.17 | Columnpm1004vdcAlmRxPwrHighWngPortn | read-only | current | Client SFP Rx Power High Warning :Warning indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> R… |
| 1.3.6.1.4.1.20044.38.2.2.1.56 | Tablepm1004vdcAlmsfpCritDdmTable | not-accessible | current | List of pm1004vdcAlmsfpCritDdm Article |
| 1.3.6.1.4.1.20044.38.2.2.1.56.1 | Rowpm1004vdcAlmsfpCritDdmEntry | not-accessible | current | Row definition for the pm1004vdcAlmsfpCritDdm table |
| 1.3.6.1.4.1.20044.38.2.2.1.56.1.1 | Columnpm1004vdcAlmsfpCritDdmIndex | read-only | current | Index definition for the pm1004vdcAlmsfpCritDdm table |
| 1.3.6.1.4.1.20044.38.2.2.1.56.1.2 | Columnpm1004vdcAlmTxPwrLowCritPortn | read-only | current | Client SFP Custom Tx Power Low :Custom Alarm indicating that the SFP output power of port is lower than the custom threshold defined in configuration <Help> Cu… |
| 1.3.6.1.4.1.20044.38.2.2.1.56.1.3 | Columnpm1004vdcAlmTxPwrHighCritPortn | read-only | current | Client SFP Custom Tx Power High :Custom Alarm indicating that the SFP output power of port is higher than the custom threshold defined in configuration <Help> … |
| 1.3.6.1.4.1.20044.38.2.2.1.56.1.16 | Columnpm1004vdcAlmRxPwrLowCritPortn | read-only | current | Client SFP Custom Rx Power Low :Custom Alarm indicating that the SFP input power of port is lower than the custom threshold defined in configuration <Help> Cus… |
| 1.3.6.1.4.1.20044.38.2.2.1.56.1.17 | Columnpm1004vdcAlmRxPwrHighCritPortn | read-only | current | Client SFP Custom Rx Power High :Custom Alarm indicating that the SFP input power of port is higher than the custom threshold defined in configuration <Help> C… |
| 1.3.6.1.4.1.20044.38.2.2.2 | Nodepm1004vdcAlmClientUrg | |||
| 1.3.6.1.4.1.20044.38.2.2.2.32 | Tablepm1004vdcAlmsfpAlmDdmTable | not-accessible | current | List of pm1004vdcAlmsfpAlmDdm Article |
| 1.3.6.1.4.1.20044.38.2.2.2.32.1 | Rowpm1004vdcAlmsfpAlmDdmEntry | not-accessible | current | Row definition for the pm1004vdcAlmsfpAlmDdm table |
| 1.3.6.1.4.1.20044.38.2.2.2.32.1.1 | Columnpm1004vdcAlmsfpAlmDdmIndex | read-only | current | Index definition for the pm1004vdcAlmsfpAlmDdm table |
| 1.3.6.1.4.1.20044.38.2.2.2.32.1.2 | Columnpm1004vdcAlmTxPwrLowAlaPortn | read-only | current | Client SFP Tx Power Low :Alarm indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> TX_PWR_LOW_A… |
| 1.3.6.1.4.1.20044.38.2.2.2.32.1.3 | Columnpm1004vdcAlmTxPwrHighAlaPortn | read-only | current | Client SFP Tx Power High :Alarm indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> TX_PWR_HIG… |
| 1.3.6.1.4.1.20044.38.2.2.2.32.1.4 | Columnpm1004vdcAlmTxBiasLowAlaPortn | read-only | current | Client SFP Bias Low :Alarm indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> TX_BIAS_LO… |
| 1.3.6.1.4.1.20044.38.2.2.2.32.1.5 | Columnpm1004vdcAlmTxBiasHighAlaPortn | read-only | current | Client SFP Bias High :Alarm indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype> TX_BIAS_… |
| 1.3.6.1.4.1.20044.38.2.2.2.32.1.6 | Columnpm1004vdcAlmVccLowAlaPortn | read-only | current | Client SFP Power Supply Low :Alarm indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype> VCC_LOW_… |
| 1.3.6.1.4.1.20044.38.2.2.2.32.1.7 | Columnpm1004vdcAlmVccHighAlaPortn | read-only | current | Client SFP Power Supply High :Alarm indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condtype> VCC_HI… |
| 1.3.6.1.4.1.20044.38.2.2.2.32.1.8 | Columnpm1004vdcAlmTempLowAlaPortn | read-only | current | Client SFP Temp Low :Alarm indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> TEMP_LOW_ALA_1 <P… |
| 1.3.6.1.4.1.20044.38.2.2.2.32.1.9 | Columnpm1004vdcAlmTempHighAlaPortn | read-only | current | Client SFP Temp High :Alarm indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> TEMP_HIGH_ALA_1… |
| 1.3.6.1.4.1.20044.38.2.2.2.32.1.16 | Columnpm1004vdcAlmRxPwrLowAlaPortn | read-only | current | Client SFP Rx Power Low :Alarm indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> RX_PWR_LOW_AL… |
| 1.3.6.1.4.1.20044.38.2.2.2.32.1.17 | Columnpm1004vdcAlmRxPwrHighAlaPortn | read-only | current | Client SFP Rx Power High :Alarm indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> RX_PWR_HIGH… |
| 1.3.6.1.4.1.20044.38.2.2.3 | Nodepm1004vdcAlmClientCrit | |||
| 1.3.6.1.4.1.20044.38.2.2.3.8 | Tablepm1004vdcAlmsynthAlmPortTable | not-accessible | current | List of pm1004vdcAlmsynthAlmPort Article |
| 1.3.6.1.4.1.20044.38.2.2.3.8.1 | Rowpm1004vdcAlmsynthAlmPortEntry | not-accessible | current | Row definition for the pm1004vdcAlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.38.2.2.3.8.1.1 | Columnpm1004vdcAlmsynthAlmPortIndex | read-only | current | Index definition for the pm1004vdcAlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.38.2.2.3.8.1.2 | Columnpm1004vdcAlmSfpAbsentPortn | read-only | current | Client Optical Module Absent :This OID indicates that the SFP module is not present in the client port (only significant on Client6-GbE port). <Help> This alar… |
| 1.3.6.1.4.1.20044.38.2.2.3.8.1.3 | Columnpm1004vdcAlmDdmAbsentPortn | read-only | current | DDM Supported On Client SFP :This OID indicates that the Client SFP module supports the Digital Diagnostic Monitoring function (only significant on Client6-GbE… |
| 1.3.6.1.4.1.20044.38.2.2.3.8.1.5 | Columnpm1004vdcAlmHwFailAccPortn | read-only | current | Client HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Condtype> HW_FAIL_ACC_1 <Probcause> equipmentMalfunction (16)… |
| 1.3.6.1.4.1.20044.38.2.2.3.8.1.6 | Columnpm1004vdcAlmDwLsdPortn | read-only | current | Client Signal Shutdown :This OID indicates the Client SFP transmitter output is ON. <Help> This status indicates if the client transceiver is ON or OFF <Condty… |
| 1.3.6.1.4.1.20044.38.2.2.3.8.1.7 | Columnpm1004vdcAlmClientLocalOosTxPortn | read-only | current | Tx Client Port In Service :This OID indicates that the local Tx Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local T… |
| 1.3.6.1.4.1.20044.38.2.2.3.8.1.8 | Columnpm1004vdcAlmClientLocalOosRxPortn | read-only | current | Rx Client Port In Service :This OID indicates that the local Rx Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local R… |
| 1.3.6.1.4.1.20044.38.2.2.3.8.1.9 | Columnpm1004vdcAlmDwCaisPortn | read-only | current | Client AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indictaes if a Client Alarm Indication Signal is… |
| 1.3.6.1.4.1.20044.38.2.2.3.8.1.10 | Columnpm1004vdcAlmSfpDdmWarningPortn | read-only | current | Warning On Client SFP DDM :This OID indicates a warning is being received from the Client SFP DDM (only significant on Client6-GbE port) <Help> This alarm indi… |
| 1.3.6.1.4.1.20044.38.2.2.3.8.1.11 | Columnpm1004vdcAlmSfpDdmAlmPortn | read-only | current | Alarm On Client SFP DDM :This OID indicates an alarm is being received from the Client SFP DDM (only significant on Client6-GbE port) <Help> This alarm indicat… |
| 1.3.6.1.4.1.20044.38.2.2.3.8.1.12 | Columnpm1004vdcAlmSfpDdmCritPortn | read-only | current | Custom Alarm On Client SFP DDM :This OID indicates a Custom alarm is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Custom Alarm h… |
| 1.3.6.1.4.1.20044.38.2.2.3.8.1.13 | Columnpm1004vdcAlmFailAccPortn | read-only | current | Client Access Fail :This OID indicates a failure on the Client port <Condtype> FAIL_ACC_1 <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12)… |
| 1.3.6.1.4.1.20044.38.2.2.3.8.1.16 | Columnpm1004vdcAlmClientActivePortn | read-only | current | Client Sink (Line1 Or Line2) :This bit indicates the Client #n is active on receive side <Help> This status indicates whether the Client is extracted from Line… |
| 1.3.6.1.4.1.20044.38.2.2.3.8.1.17 | Columnpm1004vdcAlmUpCsfPortn | read-only | current | Client Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu… |
| 1.3.6.1.4.1.20044.38.2.2.3.16 | Tablepm1004vdcAlmaccessioAlmTable | not-accessible | current | List of pm1004vdcAlmaccessioAlm Article |
| 1.3.6.1.4.1.20044.38.2.2.3.16.1 | Rowpm1004vdcAlmaccessioAlmEntry | not-accessible | current | Row definition for the pm1004vdcAlmaccessioAlm table |
| 1.3.6.1.4.1.20044.38.2.2.3.16.1.1 | Columnpm1004vdcAlmaccessioAlmIndex | read-only | current | Index definition for the pm1004vdcAlmaccessioAlm table |
| 1.3.6.1.4.1.20044.38.2.2.3.16.1.2 | Columnpm1004vdcAlmDwLasFailPortn | read-only | current | Client SFP Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the client port. This alarm reports the transmitter failure alarm … |
| 1.3.6.1.4.1.20044.38.2.2.3.16.1.5 | Columnpm1004vdcAlmUpLosPortn | read-only | current | Client Input Loss Of Signal :This OID indicates that no signal is present on the client port <Help> This alarm indicates if a signal is detected on the client … |
| 1.3.6.1.4.1.20044.38.2.2.3.72 | Tablepm1004vdcAlmmapperDeAlmTable | not-accessible | current | List of pm1004vdcAlmmapperDeAlm Article |
| 1.3.6.1.4.1.20044.38.2.2.3.72.1 | Rowpm1004vdcAlmmapperDeAlmEntry | not-accessible | current | Row definition for the pm1004vdcAlmmapperDeAlm table |
| 1.3.6.1.4.1.20044.38.2.2.3.72.1.1 | Columnpm1004vdcAlmmapperDeAlmIndex | read-only | current | Index definition for the pm1004vdcAlmmapperDeAlm table |
| 1.3.6.1.4.1.20044.38.2.2.3.72.1.2 | Columnpm1004vdcAlmUpAccOosPortn | read-only | current | Client Loss Of Synchro :This OID indicates the upstream client input port has lost synchronization on its decoder <Help> This alarms indicates if the input cli… |
| 1.3.6.1.4.1.20044.38.2.2.3.72.1.11 | Columnpm1004vdcAlmUpBufferOvlPortn | read-only | current | Client Upstream Buffer Overload :This OID indicates that the rate adaptation buffer for client port is in overload. <Help> This alarm indicates if there is a u… |
| 1.3.6.1.4.1.20044.38.2.2.3.72.1.12 | Columnpm1004vdcAlmDwCsfDetPortn | read-only | current | Client Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client… |
| 1.3.6.1.4.1.20044.38.2.2.3.72.1.15 | Columnpm1004vdcAlmDwBufferOvlPortn | read-only | current | Client Downstream Buffer Overload :This OID indicates that the de-mapper buffer for client port is in overload. <Help> This alarm indicates if there is a downs… |
| 1.3.6.1.4.1.20044.38.2.2.3.112 | Tablepm1004vdcAlmvideoProtocolStatusTable | not-accessible | current | List of pm1004vdcAlmvideoProtocolStatus Article |
| 1.3.6.1.4.1.20044.38.2.2.3.112.1 | Rowpm1004vdcAlmvideoProtocolStatusEntry | not-accessible | current | Row definition for the pm1004vdcAlmvideoProtocolStatus table |
| 1.3.6.1.4.1.20044.38.2.2.3.112.1.1 | Columnpm1004vdcAlmvideoProtocolStatusIndex | read-only | current | Index definition for the pm1004vdcAlmvideoProtocolStatus table |
| 1.3.6.1.4.1.20044.38.2.2.3.112.1.2 | Columnpm1004vdcAlmSdiTxPortn | read-only | current | SDI Detected On Tx :This OID indicates that the SDI protocol has been detected on the transmit side of the port (only significant on Video2 to Video 5 ports) <… |
| 1.3.6.1.4.1.20044.38.2.2.3.112.1.3 | Columnpm1004vdcAlmHdSdiPalTxPortn | read-only | current | HD-SDI-PAL Detected On Tx :This OID indicates that the HD-SDI-PAL protocol has been detected on the transmit side of the port (only significant on Video2 to Vi… |
| 1.3.6.1.4.1.20044.38.2.2.3.112.1.4 | Columnpm1004vdcAlmHdSdiNtscTxPortn | read-only | current | HD-SDI-NTSC Detected On Tx :This OID indicates that the HD-SDI-NTSC protocol has been detected on the transmit side of the port (only significant on Video2 to … |
| 1.3.6.1.4.1.20044.38.2.2.3.112.1.5 | Columnpm1004vdcAlmDvbAsiTxPortn | read-only | current | DVB-ASI Detected On Tx :This OID indicates that the DVB-ASI protocol has been detected on the transmit side of the port (only significant on Video2 to Video 5 … |
| 1.3.6.1.4.1.20044.38.2.2.3.112.1.6 | Columnpm1004vdcAlmFastEtherTxPortn | read-only | current | Fast Ethernet Detected On Tx :This OID indicates that the Fast Ethernet protocol has been detected on the port (only significant on Client1-RJ45 port) <Help> T… |
| 1.3.6.1.4.1.20044.38.2.2.3.112.1.7 | Columnpm1004vdcAlmGbeTxPortn | read-only | current | Gigabit Ethernet Detected On Tx :This OID indicates that the Gigabit Ethernet protocol has been detected on the port (only significant on Client6-GbE port) <He… |
| 1.3.6.1.4.1.20044.38.2.2.3.112.1.10 | Columnpm1004vdcAlmSdiRxPortn | read-only | current | SDI Detected On Rx :This OID indicates that the SDI protocol has been detected on the receive side of the port (only significant on Video2 to Video 5 ports) <H… |
| 1.3.6.1.4.1.20044.38.2.2.3.112.1.11 | Columnpm1004vdcAlmHdSdiPalRxPortn | read-only | current | HD-SDI-PAL Detected On Rx :This OID indicates that the HD-SDI-PAL protocol has been detected on the receive side of the port (only significant on Video2 to Vid… |
| 1.3.6.1.4.1.20044.38.2.2.3.112.1.12 | Columnpm1004vdcAlmHdSdiNtscRxPortn | read-only | current | HD-SDI-NTSC Detected On Rx :This OID indicates that the HD-SDI-NTSC protocol has been detected on the receive side of the port (only significant on Video2 to V… |
| 1.3.6.1.4.1.20044.38.2.2.3.112.1.13 | Columnpm1004vdcAlmDvbAsiRxPortn | read-only | current | DVB-ASI Detected On Rx :This OID indicates that the DVB-ASI protocol has been detected on the receive side of the port (only significant on Video2 to Video 5 p… |
| 1.3.6.1.4.1.20044.38.2.2.3.112.1.14 | Columnpm1004vdcAlmFastEtherRxPortn | read-only | current | Fast Ethernet Detected On Rx :This OID indicates that the Fast Ethernet protocol has been detected on the port (only significant on Client1-RJ45 port) <Help> T… |
| 1.3.6.1.4.1.20044.38.2.2.3.112.1.15 | Columnpm1004vdcAlmGbeRxPortn | read-only | current | Gigabit Ethernet Detected On Rx :This OID indicates that the Gigabit Ethernet protocol has been detected on the port (only significant on Client6-GbE port) <He… |
| 1.3.6.1.4.1.20044.38.2.3 | Nodepm1004vdcAlmLine | |||
| 1.3.6.1.4.1.20044.38.2.3.1 | Nodepm1004vdcAlmLineNurg | |||
| 1.3.6.1.4.1.20044.38.2.3.1.209 | Tablepm1004vdcAlmlineXfp1WarningsTable | not-accessible | current | List of pm1004vdcAlmlineXfp1Warnings Article |
| 1.3.6.1.4.1.20044.38.2.3.1.209.1 | Rowpm1004vdcAlmlineXfp1WarningsEntry | not-accessible | current | Row definition for the pm1004vdcAlmlineXfp1Warnings table |
| 1.3.6.1.4.1.20044.38.2.3.1.209.1.1 | Columnpm1004vdcAlmlineXfp1WarningsIndex | read-only | current | Index definition for the pm1004vdcAlmlineXfp1Warnings table |
| 1.3.6.1.4.1.20044.38.2.3.1.209.1.2 | Columnpm1004vdcAlmTxPowerLowWarningPortn | read-only | current | Line Optical Tx Power Low Warning :Warning indicating that the XFP/OTX transmitter transmitter output power is lower than the threshold value written in the XF… |
| 1.3.6.1.4.1.20044.38.2.3.1.209.1.3 | Columnpm1004vdcAlmTxPowerHighWarningPortn | read-only | current | Line Optical Tx Power High Warning :Warning indicating that the XFP/OTX transmitter transmitter output power is higher than the threshold value written in the … |
| 1.3.6.1.4.1.20044.38.2.3.1.209.1.4 | Columnpm1004vdcAlmTxBiasLowWarningPortn | read-only | current | Line Transceiver Bias Low Warning :Warning indicating that the XFP/OTX transmitter laser bias current is lower than the threshold value written in the XFP/OTX … |
| 1.3.6.1.4.1.20044.38.2.3.1.209.1.5 | Columnpm1004vdcAlmTxBiasHighWarningPortn | read-only | current | Line Transceiver Bias High Warning :Warning indicating that the XFP/OTX transmitter laser bias current is higher than the threshold value written in the XFP EE… |
| 1.3.6.1.4.1.20044.38.2.3.1.209.1.8 | Columnpm1004vdcAlmTempLowWarningPortn | read-only | current | Line Transceiver Temp Low Warning :Warning indicating that the XFP/OTX temperature is lower than the threshold value written in the XFP/OTX EEPROM <Condtype> T… |
| 1.3.6.1.4.1.20044.38.2.3.1.209.1.9 | Columnpm1004vdcAlmTempHighWarningPortn | read-only | current | Line Transceiver Temp High Warning :Warning indicating that the XFP/OTX temperature is higher than the threshold value written in the XFP EEPROM <Condtype> TEM… |
| 1.3.6.1.4.1.20044.38.2.3.1.209.1.16 | Columnpm1004vdcAlmRxPowerLowWarningPortn | read-only | current | Line Optical Rx Power Low Warning :Warning indicating that the XFP received optical power is lower than the threshold value written in the XFP EEPROM <Condtype… |
| 1.3.6.1.4.1.20044.38.2.3.1.209.1.17 | Columnpm1004vdcAlmRxPowerHighWarningPortn | read-only | current | Line Optical Rx Power High Warning :Warning indicating that the XFP received optical power is higher than the threshold value written in the XFP EEPROM <Condty… |
| 1.3.6.1.4.1.20044.38.2.3.1.225 | Tablepm1004vdcAlmlineOtx1TlhWarningsTable | not-accessible | current | List of pm1004vdcAlmlineOtx1TlhWarnings Article |
| 1.3.6.1.4.1.20044.38.2.3.1.225.1 | Rowpm1004vdcAlmlineOtx1TlhWarningsEntry | not-accessible | current | Row definition for the pm1004vdcAlmlineOtx1TlhWarnings table |
| 1.3.6.1.4.1.20044.38.2.3.1.225.1.1 | Columnpm1004vdcAlmlineOtx1TlhWarningsIndex | read-only | current | Index definition for the pm1004vdcAlmlineOtx1TlhWarnings table |
| 1.3.6.1.4.1.20044.38.2.3.1.225.1.6 | Columnpm1004vdcAlmLineModulatorAgingHighWarningPortn | read-only | current | Line Modulator Aging High Warning :Warning indicating the Line OTX TLH modulator aging is higher than the threshold written in the EEPROM <Condtype> LINE_MODUL… |
| 1.3.6.1.4.1.20044.38.2.3.1.225.1.7 | Columnpm1004vdcAlmLineAgingHighWarningPortn | read-only | current | Line OTX TLH Aging High Warning :Warning indicating the Line OTX TLH aging is higher than the threshold written in the EEPROM <Condtype> LINE_AGING_HIGH_WARNIN… |
| 1.3.6.1.4.1.20044.38.2.3.1.225.1.13 | Columnpm1004vdcAlmLineFreqDevHighWarningPortn | read-only | current | Line Freq. Deviation High Warning :Warning indicating the Line OTX TLH frequency deviation is higher than the threshold written in the EEPROM <Condtype> LINE_F… |
| 1.3.6.1.4.1.20044.38.2.3.1.225.1.15 | Columnpm1004vdcAlmLineLaserTempHighWarningPortn | read-only | current | Line Laser Temp. High Warning :Warning indicating the Line OTX TLH laser temperature is higher than the threshold written in the EEPROM <Condtype> LINE_LASER_T… |
| 1.3.6.1.4.1.20044.38.2.3.2 | Nodepm1004vdcAlmLineUrg | |||
| 1.3.6.1.4.1.20044.38.2.3.2.208 | Tablepm1004vdcAlmlineXfp1AlarmTable | not-accessible | current | List of pm1004vdcAlmlineXfp1Alarm Article |
| 1.3.6.1.4.1.20044.38.2.3.2.208.1 | Rowpm1004vdcAlmlineXfp1AlarmEntry | not-accessible | current | Row definition for the pm1004vdcAlmlineXfp1Alarm table |
| 1.3.6.1.4.1.20044.38.2.3.2.208.1.1 | Columnpm1004vdcAlmlineXfp1AlarmIndex | read-only | current | Index definition for the pm1004vdcAlmlineXfp1Alarm table |
| 1.3.6.1.4.1.20044.38.2.3.2.208.1.2 | Columnpm1004vdcAlmTxPowerLowAlarmPortn | read-only | current | Line Optical Tx Power Low :Alarm indicating that the XFP/OTX transmitter transmitter output power is lower than the threshold value written in the XFP/OTX EEPR… |
| 1.3.6.1.4.1.20044.38.2.3.2.208.1.3 | Columnpm1004vdcAlmTxPowerHighAlarmPortn | read-only | current | Line Optical Tx Power High :Alarm indicating that the XFP/OTX transmitter transmitter output power is higher than the threshold value written in the XFP EEPROM… |
| 1.3.6.1.4.1.20044.38.2.3.2.208.1.4 | Columnpm1004vdcAlmTxBiasLowAlarmPortn | read-only | current | Line Transceiver Bias Low :Alarm indicating that the XFP/OTX transmitter laser bias current is lower than the threshold value written in the XFP/OTX EEPROM <Co… |
| 1.3.6.1.4.1.20044.38.2.3.2.208.1.5 | Columnpm1004vdcAlmTxBiasHighAlarmPortn | read-only | current | Line Transceiver Bias High :Alarm indicating that the XFP/OTX transmitter laser bias current is higher than the threshold value written in the XFP EEPROM <Cond… |
| 1.3.6.1.4.1.20044.38.2.3.2.208.1.8 | Columnpm1004vdcAlmTempLowAlarmPortn | read-only | current | Line Transceiver Temp Low :Alarm indicating that the XFP/OTX temperature is lower than the threshold value written in the XFP/OTX EEPROM <Condtype> TEMP_LOW_AL… |
| 1.3.6.1.4.1.20044.38.2.3.2.208.1.9 | Columnpm1004vdcAlmTempHighAlarmPortn | read-only | current | Line Transceiver Temp High :Alarm indicating that the XFP/OTX temperature is higher than the threshold value written in the XFP EEPROM <Condtype> TEMP_HIGH_ALA… |
| 1.3.6.1.4.1.20044.38.2.3.2.208.1.16 | Columnpm1004vdcAlmRxPowerLowAlarmPortn | read-only | current | Line Optical Rx Power Low :Alarm indicating that the XFP received optical power is lower than the threshold value written in the XFP EEPROM <Condtype> RX_POWER… |
| 1.3.6.1.4.1.20044.38.2.3.2.208.1.17 | Columnpm1004vdcAlmRxPowerHighAlarmPortn | read-only | current | Line Optical Rx Power High :Alarm indicating that the XFP received optical power is higher than the threshold value written in the XFP EEPROM <Condtype> RX_POW… |
| 1.3.6.1.4.1.20044.38.2.3.2.210 | Tablepm1004vdcAlmlineXfp1CritTable | not-accessible | current | List of pm1004vdcAlmlineXfp1Crit Article |
| 1.3.6.1.4.1.20044.38.2.3.2.210.1 | Rowpm1004vdcAlmlineXfp1CritEntry | not-accessible | current | Row definition for the pm1004vdcAlmlineXfp1Crit table |
| 1.3.6.1.4.1.20044.38.2.3.2.210.1.1 | Columnpm1004vdcAlmlineXfp1CritIndex | read-only | current | Index definition for the pm1004vdcAlmlineXfp1Crit table |
| 1.3.6.1.4.1.20044.38.2.3.2.210.1.2 | Columnpm1004vdcAlmTxPowerLowCritPortn | read-only | current | Line Custom Tx Power Low :Custom Alarm indicating that the XFP/OTX output power of port is lower than the custom threshold defined in configuration <Help> Cust… |
| 1.3.6.1.4.1.20044.38.2.3.2.210.1.3 | Columnpm1004vdcAlmTxPowerHighCritPortn | read-only | current | Line Custom Tx Power High :Custom Alarm indicating that the XFP/OTX output power of port is higher than the custom threshold defined in configuration <Help> Cu… |
| 1.3.6.1.4.1.20044.38.2.3.2.210.1.16 | Columnpm1004vdcAlmRxPowerLowCritPortn | read-only | current | Line Custom Rx Power Low :Custom Alarm indicating that the XFP/OTX input power of port is lower than the custom threshold defined in configuration <Help> Custo… |
| 1.3.6.1.4.1.20044.38.2.3.2.210.1.17 | Columnpm1004vdcAlmRxPowerHighCritPortn | read-only | current | Line Custom Rx Power High :Custom Alarm indicating that the XFP/OTX input power of port is higher than the custom threshold defined in configuration <Help> Cus… |
| 1.3.6.1.4.1.20044.38.2.3.2.212 | Tablepm1004vdcAlmlineXfp1SupplyAlarmTable | not-accessible | current | List of pm1004vdcAlmlineXfp1SupplyAlarm Article |
| 1.3.6.1.4.1.20044.38.2.3.2.212.1 | Rowpm1004vdcAlmlineXfp1SupplyAlarmEntry | not-accessible | current | Row definition for the pm1004vdcAlmlineXfp1SupplyAlarm table |
| 1.3.6.1.4.1.20044.38.2.3.2.212.1.1 | Columnpm1004vdcAlmlineXfp1SupplyAlarmIndex | read-only | current | Index definition for the pm1004vdcAlmlineXfp1SupplyAlarm table |
| 1.3.6.1.4.1.20044.38.2.3.2.212.1.2 | Columnpm1004vdcAlmVee5LowAlarmPortn | read-only | current | VEE5 Power Supply Low :Alarm indicating the XFP/OTX VEE5 power supply is lower than the threshold written in the EEPROM <Condtype> VEE5_LOW_ALARM_1 <Probcause>… |
| 1.3.6.1.4.1.20044.38.2.3.2.212.1.3 | Columnpm1004vdcAlmVee5HighAlarmPortn | read-only | current | VEE5 Power Supply High :Alarm indicating the XFP/OTX VEE5 power supply is higher than the threshold written in the EEPROM <Condtype> VEE5_HIGH_ALARM_1 <Probcau… |
| 1.3.6.1.4.1.20044.38.2.3.2.212.1.4 | Columnpm1004vdcAlmVcc2LowAlarmPortn | read-only | current | VCC2 Power Supply Low :Alarm indicating the XFP/OTX VCC2 power supply is lower than the threshold written in the EEPROM <Condtype> VCC2_LOW_ALARM_1 <Probcause>… |
| 1.3.6.1.4.1.20044.38.2.3.2.212.1.5 | Columnpm1004vdcAlmVcc2HighAlarmPortn | read-only | current | VCC2 Power Supply High :Alarm indicating the XFP/OTX VCC2 power supply is higher than the threshold written in the EEPROM <Condtype> VCC2_HIGH_ALARM_1 <Probcau… |
| 1.3.6.1.4.1.20044.38.2.3.2.212.1.6 | Columnpm1004vdcAlmVcc3LowAlarmPortn | read-only | current | VCC3 Power Supply Low :Alarm indicating the XFP/OTX VCC3 power supply is lower than the threshold written in the EEPROM <Condtype> VCC3_LOW_ALARM_1 <Probcause>… |
| 1.3.6.1.4.1.20044.38.2.3.2.212.1.7 | Columnpm1004vdcAlmVcc3HighAlarmPortn | read-only | current | VCC3 Power Supply High :Alarm indicating the XFP/OTX VCC3 power supply is higher than the threshold written in the EEPROM <Condtype> VCC3_HIGH_ALARM_1 <Probcau… |
| 1.3.6.1.4.1.20044.38.2.3.2.212.1.8 | Columnpm1004vdcAlmVcc5LowAlarmPortn | read-only | current | VCC5 Power Supply Low :Alarm indicating the XFP/OTX VCC5 power supply is lower than the threshold written in the EEPROM <Condtype> VCC5_LOW_ALARM_1 <Probcause>… |
| 1.3.6.1.4.1.20044.38.2.3.2.212.1.9 | Columnpm1004vdcAlmVcc5HighAlarmPortn | read-only | current | VCC5 Power Supply High :Alarm indicating the XFP/OTX VCC5 power supply is higher than the threshold written in the EEPROM <Condtype> VCC5_HIGH_ALARM_1 <Probcau… |
| 1.3.6.1.4.1.20044.38.2.3.2.212.1.10 | Columnpm1004vdcAlmVee5LowWarningPortn | read-only | current | VEE5 Power Supply Low Warning :Warning indicating the XFP/OTX VEE5 power supply is lower than the threshold written in the EEPROM <Condtype> VEE5_LOW_WARNING_1… |
| 1.3.6.1.4.1.20044.38.2.3.2.212.1.11 | Columnpm1004vdcAlmVee5HighWarningPortn | read-only | current | VEE5 Power Supply High Warning :Warning indicating the XFP/OTX VEE5 power supply is higher than the threshold written in the EEPROM <Condtype> VEE5_HIGH_WARNIN… |
| 1.3.6.1.4.1.20044.38.2.3.2.212.1.12 | Columnpm1004vdcAlmVcc2LowWarningPortn | read-only | current | VCC2 Power Supply Low Warning :Warning indicating the XFP/OTX VCC2 power supply is lower than the threshold written in the EEPROM <Condtype> VCC2_LOW_WARNING_1… |
| 1.3.6.1.4.1.20044.38.2.3.2.212.1.13 | Columnpm1004vdcAlmVcc2HighWarningPortn | read-only | current | VCC2 Power Supply High Warning :Warning indicating the XFP/OTX VCC2 power supply is higher than the threshold written in the EEPROM <Condtype> VCC2_HIGH_WARNIN… |
| 1.3.6.1.4.1.20044.38.2.3.2.212.1.14 | Columnpm1004vdcAlmVcc3LowWarningPortn | read-only | current | VCC3 Power Supply Low Warning :Warning indicating the XFP/OTX VCC3 power supply is lower than the threshold written in the EEPROM <Condtype> VCC3_LOW_WARNING_1… |
| 1.3.6.1.4.1.20044.38.2.3.2.212.1.15 | Columnpm1004vdcAlmVcc3HighWarningPortn | read-only | current | VCC3 Power Supply High Warning :Warning indicating the XFP/OTX VCC3 power supply is higher than the threshold written in the EEPROM <Condtype> VCC3_HIGH_WARNIN… |
| 1.3.6.1.4.1.20044.38.2.3.2.212.1.16 | Columnpm1004vdcAlmVcc5LowWarningPortn | read-only | current | VCC5 Power Supply Low Warning :Warning indicating the XFP/OTX VCC5 power supply is lower than the threshold written in the EEPROM <Condtype> VCC5_LOW_WARNING_1… |
| 1.3.6.1.4.1.20044.38.2.3.2.212.1.17 | Columnpm1004vdcAlmVcc5HighWarningPortn | read-only | current | VCC5 Power Supply High Warning :Warning indicating the XFP/OTX VCC5 power supply is higher than the threshold written in the EEPROM <Condtype> VCC5_HIGH_WARNIN… |
| 1.3.6.1.4.1.20044.38.2.3.2.224 | Tablepm1004vdcAlmlineOtx1TlhAlarmsTable | not-accessible | current | List of pm1004vdcAlmlineOtx1TlhAlarms Article |
| 1.3.6.1.4.1.20044.38.2.3.2.224.1 | Rowpm1004vdcAlmlineOtx1TlhAlarmsEntry | not-accessible | current | Row definition for the pm1004vdcAlmlineOtx1TlhAlarms table |
| 1.3.6.1.4.1.20044.38.2.3.2.224.1.1 | Columnpm1004vdcAlmlineOtx1TlhAlarmsIndex | read-only | current | Index definition for the pm1004vdcAlmlineOtx1TlhAlarms table |
| 1.3.6.1.4.1.20044.38.2.3.2.224.1.6 | Columnpm1004vdcAlmLineModulatorAgingHighAlaPortn | read-only | current | Line Modulator Aging High Alarm :Alarm indicating the Line OTX TLH modulator aging is higher than the threshold written in the EEPROM <Condtype> LINE_MODULATOR… |
| 1.3.6.1.4.1.20044.38.2.3.2.224.1.7 | Columnpm1004vdcAlmLineAgingHighAlaPortn | read-only | current | Line OTX TLH Aging High Alarm :Alarm indicating the Line OTX TLH aging is higher than the threshold written in the EEPROM <Condtype> LINE_AGING_HIGH_ALA_1 <Pro… |
| 1.3.6.1.4.1.20044.38.2.3.2.224.1.13 | Columnpm1004vdcAlmLineFreqDevHighAlaPortn | read-only | current | Line Freq. Deviation High Alarm :Alarm indicating the Line OTX TLH frequency deviation is higher than the threshold written in the EEPROM <Condtype> LINE_FREQ_… |
| 1.3.6.1.4.1.20044.38.2.3.2.224.1.15 | Columnpm1004vdcAlmLineLaserTempHighAlaPortn | read-only | current | Line Laser Temp. High Alarm :Alarm indicating the Line OTX TLH laser temperature is higher than the threshold written in the EEPROM <Condtype> LINE_LASER_TEMP_… |
| 1.3.6.1.4.1.20044.38.2.3.3 | Nodepm1004vdcAlmLineCrit | |||
| 1.3.6.1.4.1.20044.38.2.3.3.7 | Tablepm1004vdcAlmsynthAlmLineTable | not-accessible | current | List of pm1004vdcAlmsynthAlmLine Article |
| 1.3.6.1.4.1.20044.38.2.3.3.7.1 | Rowpm1004vdcAlmsynthAlmLineEntry | not-accessible | current | Row definition for the pm1004vdcAlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.38.2.3.3.7.1.1 | Columnpm1004vdcAlmsynthAlmLineIndex | read-only | current | Index definition for the pm1004vdcAlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.38.2.3.3.7.1.2 | Columnpm1004vdcAlmXfpAbsentPortn | read-only | current | Line Optical Module Absent :This OID indicates that the line optical interface (XFP or OTX) is not plugged in. <Help> This alarm indicates if the line transcei… |
| 1.3.6.1.4.1.20044.38.2.3.3.7.1.3 | Columnpm1004vdcAlmXfpInitNotComplPortn | read-only | current | Line Optical Module Ready :This OID indicates that the optical interface (XFP or OTX) is not operational. <Help> This status indicates if the line transceiver … |
| 1.3.6.1.4.1.20044.38.2.3.3.7.1.5 | Columnpm1004vdcAlmLineHwFailPortn | read-only | current | Line Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Condtype> LINE_HW_FAIL <Probcause> equipmentMalfunction (1… |
| 1.3.6.1.4.1.20044.38.2.3.3.7.1.6 | Columnpm1004vdcAlmXfpTxOffPortn | read-only | current | Line Optical Module Laser Shutdown :This OID indicates the line optical output power is on <Help> This status indicates if the line transceiver laser is ON or … |
| 1.3.6.1.4.1.20044.38.2.3.3.7.1.7 | Columnpm1004vdcAlmLineLocalOosPortn | read-only | current | Line Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service… |
| 1.3.6.1.4.1.20044.38.2.3.3.7.1.10 | Columnpm1004vdcAlmLineDdmWarningPortn | read-only | current | Warning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Warni… |
| 1.3.6.1.4.1.20044.38.2.3.3.7.1.11 | Columnpm1004vdcAlmLineDdmAlmPortn | read-only | current | Alarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Alarm ha… |
| 1.3.6.1.4.1.20044.38.2.3.3.7.1.12 | Columnpm1004vdcAlmLineDdmCritPortn | read-only | current | Custom Alarm On Line XFP/OTX DDM :This OID indicates a Custom alarm is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Cu… |
| 1.3.6.1.4.1.20044.38.2.3.3.7.1.13 | Columnpm1004vdcAlmLineFailPortn | read-only | current | Line Port Failure :This OID indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12) <Po… |
| 1.3.6.1.4.1.20044.38.2.3.3.7.1.17 | Columnpm1004vdcAlmLineActivePortn | read-only | current | Line Active :This bit indicates the line #n is active on receive side <Help> This status indicates whether the line is active or standby. <Condtype> LINE_ACTIV… |
| 1.3.6.1.4.1.20044.38.2.3.3.128 | Tablepm1004vdcAlmdfrmAlmTable | not-accessible | current | List of pm1004vdcAlmdfrmAlm Article |
| 1.3.6.1.4.1.20044.38.2.3.3.128.1 | Rowpm1004vdcAlmdfrmAlmEntry | not-accessible | current | Row definition for the pm1004vdcAlmdfrmAlm table |
| 1.3.6.1.4.1.20044.38.2.3.3.128.1.1 | Columnpm1004vdcAlmdfrmAlmIndex | read-only | current | Index definition for the pm1004vdcAlmdfrmAlm table |
| 1.3.6.1.4.1.20044.38.2.3.3.128.1.5 | Columnpm1004vdcAlmDwLossofsyncPortn | read-only | current | Loss Of Synchronisation :This OID indicates the upstream line input port is in Loss of Synchronization. <Help> This alarms indicates if the input signal is cor… |
| 1.3.6.1.4.1.20044.38.2.3.3.133 | Tablepm1004vdcAlmlineSyncAlarmsTable | not-accessible | current | List of pm1004vdcAlmlineSyncAlarms Article |
| 1.3.6.1.4.1.20044.38.2.3.3.133.1 | Rowpm1004vdcAlmlineSyncAlarmsEntry | not-accessible | current | Row definition for the pm1004vdcAlmlineSyncAlarms table |
| 1.3.6.1.4.1.20044.38.2.3.3.133.1.1 | Columnpm1004vdcAlmlineSyncAlarmsIndex | read-only | current | Index definition for the pm1004vdcAlmlineSyncAlarms table |
| 1.3.6.1.4.1.20044.38.2.3.3.133.1.13 | Columnpm1004vdcAlmDwLockerrPortn | read-only | current | Downstream Clock Lock Error :This OID indicates that the deserializer input 10 Gb/s clock recovery is not locked. <Condtype> DW_LOCKERR <Probcause> receiveFail… |
| 1.3.6.1.4.1.20044.38.2.3.3.133.1.14 | Columnpm1004vdcAlmUpLockerrPortn | read-only | current | Upstream Clock Lock Error :This OID indicates that the serializer output 10 Gb/s clock multiplier unit is not locked. <Condtype> UP_LOCKERR <Probcause> receive… |
| 1.3.6.1.4.1.20044.38.2.3.3.133.1.17 | Columnpm1004vdcAlmDwLosPortn | read-only | current | Line Input Loss Of Signal :This OID indicates a loss of signal on the 10 Gb/s input. <Help> This alarm indicates if an optical signal is detected on the line t… |
| 1.3.6.1.4.1.20044.38.2.3.3.211 | Tablepm1004vdcAlmlineXfp1AlarmsTable | not-accessible | current | List of pm1004vdcAlmlineXfp1Alarms Article |
| 1.3.6.1.4.1.20044.38.2.3.3.211.1 | Rowpm1004vdcAlmlineXfp1AlarmsEntry | not-accessible | current | Row definition for the pm1004vdcAlmlineXfp1Alarms table |
| 1.3.6.1.4.1.20044.38.2.3.3.211.1.1 | Columnpm1004vdcAlmlineXfp1AlarmsIndex | read-only | current | Index definition for the pm1004vdcAlmlineXfp1Alarms table |
| 1.3.6.1.4.1.20044.38.2.3.3.211.1.3 | Columnpm1004vdcAlmModNrPortn | read-only | current | Line Optical Module Not Ready :This OID indicates that the module is unable to determine correct data. <Help> This alarm indicates if the line transceiver is r… |
| 1.3.6.1.4.1.20044.38.2.3.3.211.1.4 | Columnpm1004vdcAlmRxCdrNotLockedPortn | read-only | current | Line Optical Rx CDR Unlocked :This OID indicates that a loss of lock on the receiving side CDR has been detected <Help> This alarm indicates if the Rx CDR is l… |
| 1.3.6.1.4.1.20044.38.2.3.3.211.1.6 | Columnpm1004vdcAlmRxNrPortn | read-only | current | Line Optical Rx Not Ready :This OID indicates that a condition has arisen leading to invalid data on the receiving side. <Help> This alarm indicates if the Rx … |
| 1.3.6.1.4.1.20044.38.2.3.3.211.1.7 | Columnpm1004vdcAlmTxCdrNotLockedPortn | read-only | current | Line Optical Tx CDR Unlocked :This OID indicates a loss of lock on the transmitting side CDR has been detected. <Help> This alarm indicates if the Tx CDR is lo… |
| 1.3.6.1.4.1.20044.38.2.3.3.211.1.8 | Columnpm1004vdcAlmTxFaultPortn | read-only | current | Line Optical Tx Failure :This OID indicates a fault condition on the laser detected by the safety syste <Help> This alarm indicates if the laser of the line tr… |
| 1.3.6.1.4.1.20044.38.2.3.3.211.1.9 | Columnpm1004vdcAlmTxNrPortn | read-only | current | Line Optical Tx Not Ready :This OID indicates a condition has arisen leading to invalid data on the transmitting side <Help> This alarm indicates if the Tx par… |
| 1.3.6.1.4.1.20044.38.2.3.3.211.1.15 | Columnpm1004vdcAlmWavelengthUnlockedPortn | read-only | current | Line Optical Tx Wavelength Unlocked :This OID indicates that the wavelength error is exceeding the manufacturer tolerance <Help> This alarm indicates if the wa… |
| 1.3.6.1.4.1.20044.38.2.3.3.211.1.16 | Columnpm1004vdcAlmTecFaultPortn | read-only | current | Line Optical Tx Temp Regul Failed :This OID indicates a failure on the TEC module <Help> This alarm indicates if the TEC of the line transceiver is in fail con… |
| 1.3.6.1.4.1.20044.38.2.3.3.211.1.17 | Columnpm1004vdcAlmApdSupplyFaultPortn | read-only | current | Line Rx Photodiode Power Failed :This OID indicates a failure on the APD power supply <Help> This alarm indicates if the APD power supply is in fail condition … |
| 1.3.6.1.4.1.20044.38.3 | Nodepm1004vdcmeasures | |||
| 1.3.6.1.4.1.20044.38.3.1 | Nodepm1004vdcMesrOther | |||
| 1.3.6.1.4.1.20044.38.3.1.0 | Scalarpm1004vdcMesrsynth0 | read-only | deprecated | Not Used :This OID gives the unit used on AUX1 measurement of XFP#1 (Unit = ) |
| 1.3.6.1.4.1.20044.38.3.1.1 | Scalarpm1004vdcMesrsynth1 | read-only | deprecated | Not Used :This OID gives the unit used on AUX2 measurement of XFP#1 (Unit = ) |
| 1.3.6.1.4.1.20044.38.3.2 | Nodepm1004vdcMesrClient | |||
| 1.3.6.1.4.1.20044.38.3.2.16 | Tablepm1004vdcMesrtempMeasTable | not-accessible | current | List of pm1004vdcMesrtempMeas Article |
| 1.3.6.1.4.1.20044.38.3.2.16.1 | Rowpm1004vdcMesrtempMeasEntry | not-accessible | current | Row definition for the pm1004vdcMesrtempMeas table |
| 1.3.6.1.4.1.20044.38.3.2.16.1.1 | Columnpm1004vdcMesrtempMeasIndex | read-only | current | Index definition for the pm1004vdcMesrtempMeas table |
| 1.3.6.1.4.1.20044.38.3.2.16.1.2 | Columnpm1004vdcMesrtempMeasPortn | read-only | current | Client SFP Temperature :This OID gives the temperature value of the SFP plugged in port, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/25… |
| 1.3.6.1.4.1.20044.38.3.2.24 | Tablepm1004vdcMesrvoltMeasTable | not-accessible | current | List of pm1004vdcMesrvoltMeas Article |
| 1.3.6.1.4.1.20044.38.3.2.24.1 | Rowpm1004vdcMesrvoltMeasEntry | not-accessible | current | Row definition for the pm1004vdcMesrvoltMeas table |
| 1.3.6.1.4.1.20044.38.3.2.24.1.1 | Columnpm1004vdcMesrvoltMeasIndex | read-only | current | Index definition for the pm1004vdcMesrvoltMeas table |
| 1.3.6.1.4.1.20044.38.3.2.24.1.2 | Columnpm1004vdcMesrvoltMeasPortn | read-only | current | Client SFP Power Supply :This OID gives the 3V3 voltage value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/100… |
| 1.3.6.1.4.1.20044.38.3.2.32 | Tablepm1004vdcMesrbiasMeasTable | not-accessible | current | List of pm1004vdcMesrbiasMeas Article |
| 1.3.6.1.4.1.20044.38.3.2.32.1 | Rowpm1004vdcMesrbiasMeasEntry | not-accessible | current | Row definition for the pm1004vdcMesrbiasMeas table |
| 1.3.6.1.4.1.20044.38.3.2.32.1.1 | Columnpm1004vdcMesrbiasMeasIndex | read-only | current | Index definition for the pm1004vdcMesrbiasMeas table |
| 1.3.6.1.4.1.20044.38.3.2.32.1.2 | Columnpm1004vdcMesrbiasMeasPortn | read-only | current | Client SFP Laser Bias :This OID gives the bias value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA… |
| 1.3.6.1.4.1.20044.38.3.2.40 | Tablepm1004vdcMesrtxpwrMeasTable | not-accessible | current | List of pm1004vdcMesrtxpwrMeas Article |
| 1.3.6.1.4.1.20044.38.3.2.40.1 | Rowpm1004vdcMesrtxpwrMeasEntry | not-accessible | current | Row definition for the pm1004vdcMesrtxpwrMeas table |
| 1.3.6.1.4.1.20044.38.3.2.40.1.1 | Columnpm1004vdcMesrtxpwrMeasIndex | read-only | current | Index definition for the pm1004vdcMesrtxpwrMeas table |
| 1.3.6.1.4.1.20044.38.3.2.40.1.2 | Columnpm1004vdcMesrtxpwrMeasPortn | read-only | current | Client SFP Tx Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV… |
| 1.3.6.1.4.1.20044.38.3.2.48 | Tablepm1004vdcMesrrxpwrMeasTable | not-accessible | current | List of pm1004vdcMesrrxpwrMeas Article |
| 1.3.6.1.4.1.20044.38.3.2.48.1 | Rowpm1004vdcMesrrxpwrMeasEntry | not-accessible | current | Row definition for the pm1004vdcMesrrxpwrMeas table |
| 1.3.6.1.4.1.20044.38.3.2.48.1.1 | Columnpm1004vdcMesrrxpwrMeasIndex | read-only | current | Index definition for the pm1004vdcMesrrxpwrMeas table |
| 1.3.6.1.4.1.20044.38.3.2.48.1.2 | Columnpm1004vdcMesrrxpwrMeasPortn | read-only | current | Client SFP Rx Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-4… |
| 1.3.6.1.4.1.20044.38.3.3 | Nodepm1004vdcMesrLine | |||
| 1.3.6.1.4.1.20044.38.3.3.208 | Tablepm1004vdcMesrxfp1LxModTempMeasTable | not-accessible | current | List of pm1004vdcMesrxfp1LxModTempMeas Article |
| 1.3.6.1.4.1.20044.38.3.3.208.1 | Rowpm1004vdcMesrxfp1LxModTempMeasEntry | not-accessible | current | Row definition for the pm1004vdcMesrxfp1LxModTempMeas table |
| 1.3.6.1.4.1.20044.38.3.3.208.1.1 | Columnpm1004vdcMesrxfp1LxModTempMeasIndex | read-only | current | Index definition for the pm1004vdcMesrxfp1LxModTempMeas table |
| 1.3.6.1.4.1.20044.38.3.3.208.1.2 | Columnpm1004vdcMesrxfp1LxModTempMeasPortn | read-only | current | Line Optical Module Temperature :This OID gives the temperature of the XFP or OTX plugged in line#n, read from the DDM (Digital Diagnostic Monitoring) (Tempera… |
| 1.3.6.1.4.1.20044.38.3.3.209 | Tablepm1004vdcMesrxfp1ReservedTable | not-accessible | deprecated | List of pm1004vdcMesrxfp1Reserved Article |
| 1.3.6.1.4.1.20044.38.3.3.209.1 | Rowpm1004vdcMesrxfp1ReservedEntry | not-accessible | deprecated | Row definition for the pm1004vdcMesrxfp1Reserved table |
| 1.3.6.1.4.1.20044.38.3.3.209.1.1 | Columnpm1004vdcMesrxfp1ReservedIndex | read-only | deprecated | Index definition for the pm1004vdcMesrxfp1Reserved table |
| 1.3.6.1.4.1.20044.38.3.3.209.1.2 | Columnpm1004vdcMesrxfp1ReservedPortn | read-only | deprecated | Not Used :Reserved |
| 1.3.6.1.4.1.20044.38.3.3.210 | Tablepm1004vdcMesrxfp1LoBiasCurrentMeasTable | not-accessible | current | List of pm1004vdcMesrxfp1LoBiasCurrentMeas Article |
| 1.3.6.1.4.1.20044.38.3.3.210.1 | Rowpm1004vdcMesrxfp1LoBiasCurrentMeasEntry | not-accessible | current | Row definition for the pm1004vdcMesrxfp1LoBiasCurrentMeas table |
| 1.3.6.1.4.1.20044.38.3.3.210.1.1 | Columnpm1004vdcMesrxfp1LoBiasCurrentMeasIndex | read-only | current | Index definition for the pm1004vdcMesrxfp1LoBiasCurrentMeas table |
| 1.3.6.1.4.1.20044.38.3.3.210.1.2 | Columnpm1004vdcMesrxfp1LoBiasCurrentMeasPortn | read-only | current | Line Optical Module Laser Bias :This OID gives the bias value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Bias = A… |
| 1.3.6.1.4.1.20044.38.3.3.211 | Tablepm1004vdcMesrxfp1LoTxPowerMeasTable | not-accessible | current | List of pm1004vdcMesrxfp1LoTxPowerMeas Article |
| 1.3.6.1.4.1.20044.38.3.3.211.1 | Rowpm1004vdcMesrxfp1LoTxPowerMeasEntry | not-accessible | current | Row definition for the pm1004vdcMesrxfp1LoTxPowerMeas table |
| 1.3.6.1.4.1.20044.38.3.3.211.1.1 | Columnpm1004vdcMesrxfp1LoTxPowerMeasIndex | read-only | current | Index definition for the pm1004vdcMesrxfp1LoTxPowerMeas table |
| 1.3.6.1.4.1.20044.38.3.3.211.1.2 | Columnpm1004vdcMesrxfp1LoTxPowerMeasPortn | read-only | current | Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (… |
| 1.3.6.1.4.1.20044.38.3.3.212 | Tablepm1004vdcMesrxfp1LiRxPowerMeasTable | not-accessible | current | List of pm1004vdcMesrxfp1LiRxPowerMeas Article |
| 1.3.6.1.4.1.20044.38.3.3.212.1 | Rowpm1004vdcMesrxfp1LiRxPowerMeasEntry | not-accessible | current | Row definition for the pm1004vdcMesrxfp1LiRxPowerMeas table |
| 1.3.6.1.4.1.20044.38.3.3.212.1.1 | Columnpm1004vdcMesrxfp1LiRxPowerMeasIndex | read-only | current | Index definition for the pm1004vdcMesrxfp1LiRxPowerMeas table |
| 1.3.6.1.4.1.20044.38.3.3.212.1.2 | Columnpm1004vdcMesrxfp1LiRxPowerMeasPortn | read-only | current | Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (P… |
| 1.3.6.1.4.1.20044.38.3.3.213 | Tablepm1004vdcMesrxfp1LxAux1MeasTable | not-accessible | deprecated | List of pm1004vdcMesrxfp1LxAux1Meas Article |
| 1.3.6.1.4.1.20044.38.3.3.213.1 | Rowpm1004vdcMesrxfp1LxAux1MeasEntry | not-accessible | deprecated | Row definition for the pm1004vdcMesrxfp1LxAux1Meas table |
| 1.3.6.1.4.1.20044.38.3.3.213.1.1 | Columnpm1004vdcMesrxfp1LxAux1MeasIndex | read-only | deprecated | Index definition for the pm1004vdcMesrxfp1LxAux1Meas table |
| 1.3.6.1.4.1.20044.38.3.3.213.1.2 | Columnpm1004vdcMesrxfp1LxAux1MeasPortn | read-only | deprecated | Not Used :This OID gives the receive power value read in the DDM (Digital Diagnostic Monitoring) of the XFP or OTX plugged in line #n (Unit = ?) |
| 1.3.6.1.4.1.20044.38.3.3.214 | Tablepm1004vdcMesrxfp1LxAux2MeasTable | not-accessible | deprecated | List of pm1004vdcMesrxfp1LxAux2Meas Article |
| 1.3.6.1.4.1.20044.38.3.3.214.1 | Rowpm1004vdcMesrxfp1LxAux2MeasEntry | not-accessible | deprecated | Row definition for the pm1004vdcMesrxfp1LxAux2Meas table |
| 1.3.6.1.4.1.20044.38.3.3.214.1.1 | Columnpm1004vdcMesrxfp1LxAux2MeasIndex | read-only | deprecated | Index definition for the pm1004vdcMesrxfp1LxAux2Meas table |
| 1.3.6.1.4.1.20044.38.3.3.214.1.2 | Columnpm1004vdcMesrxfp1LxAux2MeasPortn | read-only | deprecated | Not Used :This OID gives the receive power value read in the DDM (Digital Diagnostic Monitoring) of the XFP or OTX plugged in line #n (Unit = ?) |
| 1.3.6.1.4.1.20044.38.3.3.224 | Tablepm1004vdcMesrotx1AgingTable | not-accessible | current | List of pm1004vdcMesrotx1Aging Article |
| 1.3.6.1.4.1.20044.38.3.3.224.1 | Rowpm1004vdcMesrotx1AgingEntry | not-accessible | current | Row definition for the pm1004vdcMesrotx1Aging table |
| 1.3.6.1.4.1.20044.38.3.3.224.1.1 | Columnpm1004vdcMesrotx1AgingIndex | read-only | current | Index definition for the pm1004vdcMesrotx1Aging table |
| 1.3.6.1.4.1.20044.38.3.3.224.1.2 | Columnpm1004vdcMesrotx1AgingPortn | read-only | current | Line OTX TLH Aging :This OID gives the aging of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Aging = AV) (Unit = %) <Help> This measure… |
| 1.3.6.1.4.1.20044.38.3.3.225 | Tablepm1004vdcMesrotx1LaserTemperatureTable | not-accessible | deprecated | List of pm1004vdcMesrotx1LaserTemperature Article |
| 1.3.6.1.4.1.20044.38.3.3.225.1 | Rowpm1004vdcMesrotx1LaserTemperatureEntry | not-accessible | deprecated | Row definition for the pm1004vdcMesrotx1LaserTemperature table |
| 1.3.6.1.4.1.20044.38.3.3.225.1.1 | Columnpm1004vdcMesrotx1LaserTemperatureIndex | read-only | deprecated | Index definition for the pm1004vdcMesrotx1LaserTemperature table |
| 1.3.6.1.4.1.20044.38.3.3.225.1.2 | Columnpm1004vdcMesrotx1LaserTemperaturePortn | read-only | deprecated | Line OTX TLH Laser Temperature :This OID gives the laser temperature of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/2… |
| 1.3.6.1.4.1.20044.38.3.3.226 | Tablepm1004vdcMesrotx1FreqDeviationTable | not-accessible | current | List of pm1004vdcMesrotx1FreqDeviation Article |
| 1.3.6.1.4.1.20044.38.3.3.226.1 | Rowpm1004vdcMesrotx1FreqDeviationEntry | not-accessible | current | Row definition for the pm1004vdcMesrotx1FreqDeviation table |
| 1.3.6.1.4.1.20044.38.3.3.226.1.1 | Columnpm1004vdcMesrotx1FreqDeviationIndex | read-only | current | Index definition for the pm1004vdcMesrotx1FreqDeviation table |
| 1.3.6.1.4.1.20044.38.3.3.226.1.2 | Columnpm1004vdcMesrotx1FreqDeviationPortn | read-only | current | Line OTX TLH Frequency Deviation :This OID gives the frequency deviation of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Deviation = (A… |
| 1.3.6.1.4.1.20044.38.3.3.227 | Tablepm1004vdcMesrotx1LaserWvlengthTable | not-accessible | current | List of pm1004vdcMesrotx1LaserWvlength Article |
| 1.3.6.1.4.1.20044.38.3.3.227.1 | Rowpm1004vdcMesrotx1LaserWvlengthEntry | not-accessible | current | Row definition for the pm1004vdcMesrotx1LaserWvlength table |
| 1.3.6.1.4.1.20044.38.3.3.227.1.1 | Columnpm1004vdcMesrotx1LaserWvlengthIndex | read-only | current | Index definition for the pm1004vdcMesrotx1LaserWvlength table |
| 1.3.6.1.4.1.20044.38.3.3.227.1.2 | Columnpm1004vdcMesrotx1LaserWvlengthPortn | read-only | current | Line Optical Module Wavelength :This OID gives the laser wavelength of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Wavelength=29979245… |
| 1.3.6.1.4.1.20044.38.4 | Nodepm1004vdccounters | |||
| 1.3.6.1.4.1.20044.38.4.1 | Nodepm1004vdcCntOther | |||
| 1.3.6.1.4.1.20044.38.4.2 | Nodepm1004vdcCntClient | |||
| 1.3.6.1.4.1.20044.38.4.3 | Nodepm1004vdcCntLine | |||
| 1.3.6.1.4.1.20044.38.4.3.152 | Tablepm1004vdcCntdfrmB1ErrCntTable | not-accessible | current | List of pm1004vdcCntdfrmB1ErrCnt Article |
| 1.3.6.1.4.1.20044.38.4.3.152.1 | Rowpm1004vdcCntdfrmB1ErrCntEntry | not-accessible | current | Row definition for the pm1004vdcCntdfrmB1ErrCnt table |
| 1.3.6.1.4.1.20044.38.4.3.152.1.1 | Columnpm1004vdcCntdfrmB1ErrCntIndex | read-only | current | Index definition for the pm1004vdcCntdfrmB1ErrCnt table |
| 1.3.6.1.4.1.20044.38.4.3.152.1.2 | Columnpm1004vdcCntdfrmB1ErrCntValuePortn | read-only | current | Line Input SM-BIP8 Errors :This counter is incremented each time a B1 error is detected on the Deframer input stream. <Help> This counter gives the number of B… |
| 1.3.6.1.4.1.20044.38.4.3.152.1.3 | Columnpm1004vdcCntdfrmB1ErrCntErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the B1 error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.38.4.3.152.1.4 | Columnpm1004vdcCntdfrmB1ErrCntOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a B1 error counter overload on Port |
| 1.3.6.1.4.1.20044.38.4.3.153 | Tablepm1004vdcCntdfrmTimCntTable | not-accessible | current | List of pm1004vdcCntdfrmTimCnt Article |
| 1.3.6.1.4.1.20044.38.4.3.153.1 | Rowpm1004vdcCntdfrmTimCntEntry | not-accessible | current | Row definition for the pm1004vdcCntdfrmTimCnt table |
| 1.3.6.1.4.1.20044.38.4.3.153.1.1 | Columnpm1004vdcCntdfrmTimCntIndex | read-only | current | Index definition for the pm1004vdcCntdfrmTimCnt table |
| 1.3.6.1.4.1.20044.38.4.3.153.1.2 | Columnpm1004vdcCntdfrmTimCntValuePortn | read-only | current | Line Timer Counter :This is the timing counter dedicated to the downstream deframer counters. It is incremented every 125 us. |
| 1.3.6.1.4.1.20044.38.4.3.153.1.3 | Columnpm1004vdcCntdfrmTimCntErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.38.4.3.153.1.4 | Columnpm1004vdcCntdfrmTimCntOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.38.4.259 | Scalarpm1004vdcCntCountersReset | read-write | current | Counters Reset:This OID resets and restarts all the counters |
| 1.3.6.1.4.1.20044.38.4.260 | Scalarpm1004vdcCntCountersStop | read-write | current | Counters stop:This OID stops all the counters |
| 1.3.6.1.4.1.20044.38.6 | Nodepm1004vdccontrolsWrite | |||
| 1.3.6.1.4.1.20044.38.6.1 | Nodepm1004vdcCtrlOther | |||
| 1.3.6.1.4.1.20044.38.6.1.1 | Nodepm1004vdcCtrlconfMgnt1 | |||
| 1.3.6.1.4.1.20044.38.6.1.1.1 | Scalarpm1004vdcCtrlConf1Load1 | read-write | current | Load Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM. |
| 1.3.6.1.4.1.20044.38.6.1.1.2 | Scalarpm1004vdcCtrlConf2Load1 | read-write | current | Load Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM. |
| 1.3.6.1.4.1.20044.38.6.1.1.10 | Scalarpm1004vdcCtrlConf2Flash1 | read-write | current | Write Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura… |
| 1.3.6.1.4.1.20044.38.6.1.1.14 | Scalarpm1004vdcCtrlConf2Clear1 | read-write | current | Clear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o… |
| 1.3.6.1.4.1.20044.38.6.1.4 | Nodepm1004vdcCtrlsynth4 | |||
| 1.3.6.1.4.1.20044.38.6.1.4.1 | Scalarpm1004vdcCtrlCorrelatOn | read-write | current | Enable Alarm Correlation :This OID enables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.38.6.1.4.2 | Scalarpm1004vdcCtrlCorrelatOff | read-write | current | Disable Alarm Correlation :This OID disables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.38.6.1.5 | Nodepm1004vdcCtrlswMgnt | |||
| 1.3.6.1.4.1.20044.38.6.1.5.2 | Scalarpm1004vdcCtrlColdReset | read-write | current | PM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> … |
| 1.3.6.1.4.1.20044.38.6.1.5.3 | Scalarpm1004vdcCtrlWarmReset | read-write | current | PM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th… |
| 1.3.6.1.4.1.20044.38.6.1.5.5 | Scalarpm1004vdcCtrlLoadSwBank1 | read-write | current | Set Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW… |
| 1.3.6.1.4.1.20044.38.6.1.5.6 | Scalarpm1004vdcCtrlLoadSwBank2 | read-write | current | Set Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S… |
| 1.3.6.1.4.1.20044.38.6.1.6 | Nodepm1004vdcCtrlgwMgnt | |||
| 1.3.6.1.4.1.20044.38.6.1.6.1 | Scalarpm1004vdcCtrlCurrentGwReset | read-write | current | Active Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting. |
| 1.3.6.1.4.1.20044.38.6.1.6.5 | Scalarpm1004vdcCtrlLoadGwBank1 | read-write | current | Set Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.38.6.1.6.6 | Scalarpm1004vdcCtrlLoadGwBank2 | read-write | current | Set Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.38.6.1.6.7 | Scalarpm1004vdcCtrlLoadGwBank3 | read-write | current | Set Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.38.6.1.6.8 | Scalarpm1004vdcCtrlLoadGwBank4 | read-write | current | Set Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.38.6.1.192 | Nodepm1004vdcCtrlledTest | |||
| 1.3.6.1.4.1.20044.38.6.1.192.1 | Scalarpm1004vdcCtrlGreenLed | read-write | current | Green Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green |
| 1.3.6.1.4.1.20044.38.6.1.192.2 | Scalarpm1004vdcCtrlRedLed | read-write | current | Red Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red |
| 1.3.6.1.4.1.20044.38.6.1.192.3 | Scalarpm1004vdcCtrlLedOff | read-write | current | Leds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF |
| 1.3.6.1.4.1.20044.38.6.1.193 | Nodepm1004vdcCtrlmoduleOosMode | |||
| 1.3.6.1.4.1.20044.38.6.1.193.1 | Scalarpm1004vdcCtrlModuleOosMode | read-write | current | PM Out Of Service :This OID sets the PM Out Of Service <Help> This control defines the service state of the complete module |
| 1.3.6.1.4.1.20044.38.6.1.197 | Nodepm1004vdcCtrlmaintenanceMode | |||
| 1.3.6.1.4.1.20044.38.6.1.197.1 | Scalarpm1004vdcCtrlMaintenanceMode | read-write | current | Enable Maintenance :This OID enables the maintenance mode on the PM. <Help> This control enables the maintenance mode on the PM. |
| 1.3.6.1.4.1.20044.38.6.2 | Nodepm1004vdcCtrlClient | |||
| 1.3.6.1.4.1.20044.38.6.2.16 | Tablepm1004vdcCtrlaccessLoopTable | not-accessible | current | List of pm1004vdcCtrlaccessLoop Article |
| 1.3.6.1.4.1.20044.38.6.2.16.1 | Rowpm1004vdcCtrlaccessLoopEntry | not-accessible | current | Row definition for the pm1004vdcCtrlaccessLoop table |
| 1.3.6.1.4.1.20044.38.6.2.16.1.1 | Columnpm1004vdcCtrlaccessLoopIndex | read-only | current | Index definition for the pm1004vdcCtrlaccessLoop table |
| 1.3.6.1.4.1.20044.38.6.2.16.1.2 | Columnpm1004vdcCtrlaccessLoopPortn | read-write | current | Client Facility Loopback :This OID operates a Client Facility Loopback, looping client input signal on the client output port. The loop is located on the clien… |
| 1.3.6.1.4.1.20044.38.6.2.18 | Tablepm1004vdcCtrlportOosModeTable | not-accessible | current | List of pm1004vdcCtrlportOosMode Article |
| 1.3.6.1.4.1.20044.38.6.2.18.1 | Rowpm1004vdcCtrlportOosModeEntry | not-accessible | current | Row definition for the pm1004vdcCtrlportOosMode table |
| 1.3.6.1.4.1.20044.38.6.2.18.1.1 | Columnpm1004vdcCtrlportOosModeIndex | read-only | current | Index definition for the pm1004vdcCtrlportOosMode table |
| 1.3.6.1.4.1.20044.38.6.2.18.1.2 | Columnpm1004vdcCtrlportOosModePortn | read-write | current | Client Out Of Service :This OID sets the Service state of the client port (In Service, Tx Out of Service, Rx Out of Service or Port (Rx and Tx) Out of Service)… |
| 1.3.6.1.4.1.20044.38.6.2.20 | Tablepm1004vdcCtrlsfpOffCtrlTable | not-accessible | current | List of pm1004vdcCtrlsfpOffCtrl Article |
| 1.3.6.1.4.1.20044.38.6.2.20.1 | Rowpm1004vdcCtrlsfpOffCtrlEntry | not-accessible | current | Row definition for the pm1004vdcCtrlsfpOffCtrl table |
| 1.3.6.1.4.1.20044.38.6.2.20.1.1 | Columnpm1004vdcCtrlsfpOffCtrlIndex | read-only | current | Index definition for the pm1004vdcCtrlsfpOffCtrl table |
| 1.3.6.1.4.1.20044.38.6.2.20.1.2 | Columnpm1004vdcCtrlsfpOffCtrlPortn | read-write | current | Signal OFF :This OID switches off the SFP. <Help> This control defines the laser state of the client transceiver |
| 1.3.6.1.4.1.20044.38.6.2.21 | Tablepm1004vdcCtrlcsfUpInsTable | not-accessible | current | List of pm1004vdcCtrlcsfUpIns Article |
| 1.3.6.1.4.1.20044.38.6.2.21.1 | Rowpm1004vdcCtrlcsfUpInsEntry | not-accessible | current | Row definition for the pm1004vdcCtrlcsfUpIns table |
| 1.3.6.1.4.1.20044.38.6.2.21.1.1 | Columnpm1004vdcCtrlcsfUpInsIndex | read-only | current | Index definition for the pm1004vdcCtrlcsfUpIns table |
| 1.3.6.1.4.1.20044.38.6.2.21.1.2 | Columnpm1004vdcCtrlcsfUpInsPortn | read-write | current | Client Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo… |
| 1.3.6.1.4.1.20044.38.6.2.22 | Tablepm1004vdcCtrlcaisDwInsTable | not-accessible | current | List of pm1004vdcCtrlcaisDwIns Article |
| 1.3.6.1.4.1.20044.38.6.2.22.1 | Rowpm1004vdcCtrlcaisDwInsEntry | not-accessible | current | Row definition for the pm1004vdcCtrlcaisDwIns table |
| 1.3.6.1.4.1.20044.38.6.2.22.1.1 | Columnpm1004vdcCtrlcaisDwInsIndex | read-only | current | Index definition for the pm1004vdcCtrlcaisDwIns table |
| 1.3.6.1.4.1.20044.38.6.2.22.1.2 | Columnpm1004vdcCtrlcaisDwInsPortn | read-write | current | Client AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port |
| 1.3.6.1.4.1.20044.38.6.2.26 | Tablepm1004vdcCtrlclientAccessTermLoopTable | not-accessible | current | List of pm1004vdcCtrlclientAccessTermLoop Article |
| 1.3.6.1.4.1.20044.38.6.2.26.1 | Rowpm1004vdcCtrlclientAccessTermLoopEntry | not-accessible | current | Row definition for the pm1004vdcCtrlclientAccessTermLoop table |
| 1.3.6.1.4.1.20044.38.6.2.26.1.1 | Columnpm1004vdcCtrlclientAccessTermLoopIndex | read-only | current | Index definition for the pm1004vdcCtrlclientAccessTermLoop table |
| 1.3.6.1.4.1.20044.38.6.2.26.1.2 | Columnpm1004vdcCtrlclientAccessTermLoopPortn | read-write | current | Client Terminal Loopback :This OID operates a Client Terminal Loopback, looping client input signal on the client output port. The loop is located on the line … |
| 1.3.6.1.4.1.20044.38.6.2.43 | Tablepm1004vdcCtrlrxVideoProtocolTable | not-accessible | current | List of pm1004vdcCtrlrxVideoProtocol Article |
| 1.3.6.1.4.1.20044.38.6.2.43.1 | Rowpm1004vdcCtrlrxVideoProtocolEntry | not-accessible | current | Row definition for the pm1004vdcCtrlrxVideoProtocol table |
| 1.3.6.1.4.1.20044.38.6.2.43.1.1 | Columnpm1004vdcCtrlrxVideoProtocolIndex | read-only | current | Index definition for the pm1004vdcCtrlrxVideoProtocol table |
| 1.3.6.1.4.1.20044.38.6.2.43.1.2 | Columnpm1004vdcCtrlrxVideoProtocolPortn | read-write | current | Force DVB ASI On RX Side :This OID selects the DVB ASI protocol on the client port and disable the auto-sensing feature <Help> This control selects the DVB ASI… |
| 1.3.6.1.4.1.20044.38.6.2.128 | Tablepm1004vdcCtrladddropClientRxProtectTable | not-accessible | current | List of pm1004vdcCtrladddropClientRxProtect Article |
| 1.3.6.1.4.1.20044.38.6.2.128.1 | Rowpm1004vdcCtrladddropClientRxProtectEntry | not-accessible | current | Row definition for the pm1004vdcCtrladddropClientRxProtect table |
| 1.3.6.1.4.1.20044.38.6.2.128.1.1 | Columnpm1004vdcCtrladddropClientRxProtectIndex | read-only | current | Index definition for the pm1004vdcCtrladddropClientRxProtect table |
| 1.3.6.1.4.1.20044.38.6.2.128.1.2 | Columnpm1004vdcCtrladddropClientRxProtectPortn | read-write | current | Client Switch Mode :This bit selects the manual (1) or automatic (0) switch method <Help> This control defines the protection switch mode on the client interfa… |
| 1.3.6.1.4.1.20044.38.6.2.136 | Tablepm1004vdcCtrladddropTsClientModeTable | not-accessible | current | List of pm1004vdcCtrladddropTsClientMode Article |
| 1.3.6.1.4.1.20044.38.6.2.136.1 | Rowpm1004vdcCtrladddropTsClientModeEntry | not-accessible | current | Row definition for the pm1004vdcCtrladddropTsClientMode table |
| 1.3.6.1.4.1.20044.38.6.2.136.1.1 | Columnpm1004vdcCtrladddropTsClientModeIndex | read-only | current | Index definition for the pm1004vdcCtrladddropTsClientMode table |
| 1.3.6.1.4.1.20044.38.6.2.136.1.2 | Columnpm1004vdcCtrladddropTsClientModePortn | read-write | current | Client Mode :This OID selects the mode on the client <Help> This control defines the mode (Add/Drop or Split&Select) of the Client |
| 1.3.6.1.4.1.20044.38.6.3 | Nodepm1004vdcCtrlLine | |||
| 1.3.6.1.4.1.20044.38.6.3.64 | Nodepm1004vdcCtrlcommAccessLoop | |||
| 1.3.6.1.4.1.20044.38.6.3.64.1 | Scalarpm1004vdcCtrlCommAccessloop | read-write | deprecated | PM Full Access Loop Mode :This OID, when set, puts the module in common access loop back, looping the 10 Gb/s output signal on the 10 Gb/s input. |
| 1.3.6.1.4.1.20044.38.6.3.66 | Nodepm1004vdcCtrllineLoop | |||
| 1.3.6.1.4.1.20044.38.6.3.66.1 | Scalarpm1004vdcCtrlLineLoop | read-write | deprecated | PM Line Loop Mode :This OID, when set at '1' puts the module in line loopback mode, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. The Ups… |
| 1.3.6.1.4.1.20044.38.6.3.73 | Nodepm1004vdcCtrlProtMgnt | |||
| 1.3.6.1.4.1.20044.38.6.3.73.1 | Scalarpm1004vdcCtrlLineNumber | read-write | current | Active Line Number : This OID sets the active line number |
| 1.3.6.1.4.1.20044.38.6.3.73.2 | Scalarpm1004vdcCtrlProtMode | read-write | current | Line Switch Mode (Auto Or Manual) :This bit selects the manual (1) or automatic (0) switch method <Help> This control defines the protection switch mode on the… |
| 1.3.6.1.4.1.20044.38.6.3.74 | Tablepm1004vdcCtrllineOosModeTable | not-accessible | current | List of pm1004vdcCtrllineOosMode Article |
| 1.3.6.1.4.1.20044.38.6.3.74.1 | Rowpm1004vdcCtrllineOosModeEntry | not-accessible | current | Row definition for the pm1004vdcCtrllineOosMode table |
| 1.3.6.1.4.1.20044.38.6.3.74.1.1 | Columnpm1004vdcCtrllineOosModeIndex | read-only | current | Index definition for the pm1004vdcCtrllineOosMode table |
| 1.3.6.1.4.1.20044.38.6.3.74.1.2 | Columnpm1004vdcCtrllineOosModePortn | read-write | current | Line Out Of Service (!Laser OFF!) :This OID sets the line port Out Of Service <Help> This control defines the service state of the line port |
| 1.3.6.1.4.1.20044.38.6.3.198 | Tablepm1004vdcCtrldccEnableTable | not-accessible | current | List of pm1004vdcCtrldccEnable Article |
| 1.3.6.1.4.1.20044.38.6.3.198.1 | Rowpm1004vdcCtrldccEnableEntry | not-accessible | current | Row definition for the pm1004vdcCtrldccEnable table |
| 1.3.6.1.4.1.20044.38.6.3.198.1.1 | Columnpm1004vdcCtrldccEnableIndex | read-only | current | Index definition for the pm1004vdcCtrldccEnable table |
| 1.3.6.1.4.1.20044.38.6.3.198.1.2 | Columnpm1004vdcCtrldccEnablePortn | read-write | current | DCC Mode : This OID enables the DCC mode on the PM <Help> This control enables the DCC mode on the PM |
| 1.3.6.1.4.1.20044.38.6.3.208 | Tablepm1004vdcCtrlxfpOnoffTable | not-accessible | current | List of pm1004vdcCtrlxfpOnoff Article |
| 1.3.6.1.4.1.20044.38.6.3.208.1 | Rowpm1004vdcCtrlxfpOnoffEntry | not-accessible | current | Row definition for the pm1004vdcCtrlxfpOnoff table |
| 1.3.6.1.4.1.20044.38.6.3.208.1.1 | Columnpm1004vdcCtrlxfpOnoffIndex | read-only | current | Index definition for the pm1004vdcCtrlxfpOnoff table |
| 1.3.6.1.4.1.20044.38.6.3.208.1.2 | Columnpm1004vdcCtrlxfpOnoffPortn | read-write | current | XFP/OTX Optical Laser OFF :This OID switches off the XFP or the OTX <Help> This control defines the laser state of the line transceiver |
| 1.3.6.1.4.1.20044.38.6.3.209 | Tablepm1004vdcCtrlxfpLineLoopTable | not-accessible | current | List of pm1004vdcCtrlxfpLineLoop Article |
| 1.3.6.1.4.1.20044.38.6.3.209.1 | Rowpm1004vdcCtrlxfpLineLoopEntry | not-accessible | current | Row definition for the pm1004vdcCtrlxfpLineLoop table |
| 1.3.6.1.4.1.20044.38.6.3.209.1.1 | Columnpm1004vdcCtrlxfpLineLoopIndex | read-only | current | Index definition for the pm1004vdcCtrlxfpLineLoop table |
| 1.3.6.1.4.1.20044.38.6.3.209.1.2 | Columnpm1004vdcCtrlxfpLineLoopPortn | read-write | current | Line Facility Loopback :This OID operates a Line Facility Loopback, looping line input signal on the line output port. The loop is located on the line transcei… |
| 1.3.6.1.4.1.20044.38.6.3.210 | Tablepm1004vdcCtrlxfpXfiLoopTable | not-accessible | current | List of pm1004vdcCtrlxfpXfiLoop Article |
| 1.3.6.1.4.1.20044.38.6.3.210.1 | Rowpm1004vdcCtrlxfpXfiLoopEntry | not-accessible | current | Row definition for the pm1004vdcCtrlxfpXfiLoop table |
| 1.3.6.1.4.1.20044.38.6.3.210.1.1 | Columnpm1004vdcCtrlxfpXfiLoopIndex | read-only | current | Index definition for the pm1004vdcCtrlxfpXfiLoop table |
| 1.3.6.1.4.1.20044.38.6.3.210.1.2 | Columnpm1004vdcCtrlxfpXfiLoopPortn | read-write | current | Line Terminal Loopback :This OID operates a Line Terminal Loopback, looping line input signal on the line output port. The loop is located on all client transc… |
| 1.3.6.1.4.1.20044.38.7 | Nodepm1004vdcri | |||
| 1.3.6.1.4.1.20044.38.7.1 | Nodepm1004vdcriTable | |||
| 1.3.6.1.4.1.20044.38.7.1.1 | Tablepm1004vdcRinvSfpTable | not-accessible | current | List of the SFPs on the selected module |
| 1.3.6.1.4.1.20044.38.7.1.1.1 | Rowpm1004vdcRinvSfpEntry | not-accessible | current | Row definition for the SFP table |
| 1.3.6.1.4.1.20044.38.7.1.1.1.1 | Columnpm1004vdcRinvSfpIndex | read-only | current | Index for SFP table |
| 1.3.6.1.4.1.20044.38.7.1.1.1.2 | Columnpm1004vdcRinvsfp | read-only | current | Inventory for the SFP: This OID contains the inventory for the SFP |
| 1.3.6.1.4.1.20044.38.7.1.2 | Tablepm1004vdcRinvLineTable | not-accessible | current | List of the XFPs on the selected module |
| 1.3.6.1.4.1.20044.38.7.1.2.1 | Rowpm1004vdcRinvLineEntry | not-accessible | current | Row definition for the XFP table |
| 1.3.6.1.4.1.20044.38.7.1.2.1.1 | Columnpm1004vdcRinvLineIndex | read-only | current | Index for XFP table |
| 1.3.6.1.4.1.20044.38.7.1.2.1.2 | Columnpm1004vdcRinvxfpLine | read-only | current | Inventory for the XFP: This OID contains the inventory for the XFP |
| 1.3.6.1.4.1.20044.38.7.2 | Scalarpm1004vdcRinvReloadInventory | read-write | current | Reload the inventory: This OID triggers an inventory reload. |
| 1.3.6.1.4.1.20044.38.7.3 | Scalarpm1004vdcRinvHwPlatform | read-only | current | HW platform description: This OID contains the description of the Hardware platform. |
| 1.3.6.1.4.1.20044.38.7.4 | Scalarpm1004vdcRinvModulePlatform | read-only | current | Module platform description: This OID contains the description of the Module. |
| 1.3.6.1.4.1.20044.38.7.5 | Scalarpm1004vdcRinvSwPlatform | read-only | current | SW platform description: This OID contains the description of the Software platform. |
| 1.3.6.1.4.1.20044.38.7.6 | Scalarpm1004vdcRinvGwPlatform | read-only | current | GW platform desciption: This OID contains the description of the Gateware platform. |
| 1.3.6.1.4.1.20044.38.8 | Nodepm1004vdcdownload | |||
| 1.3.6.1.4.1.20044.38.8.1 | Nodepm1004vdcDwlOther | |||
| 1.3.6.1.4.1.20044.38.8.1.0 | Nodepm1004vdcDwlrestartProcess | |||
| 1.3.6.1.4.1.20044.38.8.1.0.1 | Scalarpm1004vdcDwlWarmRestartProcessed | read-only | current | Warm Restart :This OID indicates that the module last restart was a Warm RESTART |
| 1.3.6.1.4.1.20044.38.8.1.0.2 | Scalarpm1004vdcDwlColdRestartProcessed | read-only | current | Cold Restart :This OID indicates that the module last restart was a Cold RESTART |
| 1.3.6.1.4.1.20044.38.8.1.1 | Nodepm1004vdcDwlswBanksUsed | |||
| 1.3.6.1.4.1.20044.38.8.1.1.1 | Scalarpm1004vdcDwlSwBank1Used | read-only | current | SW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.38.8.1.1.2 | Scalarpm1004vdcDwlSwBank2Used | read-only | current | SW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby |
| 1.3.6.1.4.1.20044.38.8.1.1.5 | Scalarpm1004vdcDwlSwBank1Notempty | read-only | current | SW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package |
| 1.3.6.1.4.1.20044.38.8.1.1.6 | Scalarpm1004vdcDwlSwBank2Notempty | read-only | current | SW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package |
| 1.3.6.1.4.1.20044.38.8.1.2 | Nodepm1004vdcDwlgwBanksUsed | |||
| 1.3.6.1.4.1.20044.38.8.1.2.1 | Scalarpm1004vdcDwlGwBank1Used | read-only | current | GW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.38.8.1.2.2 | Scalarpm1004vdcDwlGwBank2Used | read-only | current | GW bank 2 active :This OID indicates the module is working on GW bank 2 |
| 1.3.6.1.4.1.20044.38.8.1.2.3 | Scalarpm1004vdcDwlGwBank3Used | read-only | current | GW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby |
| 1.3.6.1.4.1.20044.38.8.1.2.4 | Scalarpm1004vdcDwlGwBank4Used | read-only | current | GW bank 4 active :This OID indicates the module is working on GW bank 4 |
| 1.3.6.1.4.1.20044.38.8.1.2.5 | Scalarpm1004vdcDwlGwBank1Notempty | read-only | current | GW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package |
| 1.3.6.1.4.1.20044.38.8.1.2.6 | Scalarpm1004vdcDwlGwBank2Notempty | read-only | current | GW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2 |
| 1.3.6.1.4.1.20044.38.8.1.2.7 | Scalarpm1004vdcDwlGwBank3Notempty | read-only | current | GW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package |
| 1.3.6.1.4.1.20044.38.8.1.2.8 | Scalarpm1004vdcDwlGwBank4Notempty | read-only | current | GW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4 |
| 1.3.6.1.4.1.20044.38.8.2 | Nodepm1004vdcDwlClient | |||
| 1.3.6.1.4.1.20044.38.8.3 | Nodepm1004vdcDwlLine | |||
| 1.3.6.1.4.1.20044.38.9 | Nodepm1004vdcConfig | |||
| 1.3.6.1.4.1.20044.38.9.1 | Nodepm1004vdcCfgAccessCAisCsf | |||
| 1.3.6.1.4.1.20044.38.9.1.1 | Tablepm1004vdcCfgClientcaiscsfTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.38.9.1.1.1 | Rowpm1004vdcCfgClientcaiscsfEntry | not-accessible | current | Row definition for the accessCAisCsf table |
| 1.3.6.1.4.1.20044.38.9.1.1.1.1 | Columnpm1004vdcCfgClientcaiscsfIndex | read-only | current | Index definition for the clientcaiscsf table |
| 1.3.6.1.4.1.20044.38.9.1.1.1.3 | Columnpm1004vdcCfgCAisModePortn | read-write | current | CAIS mode on Client Port :This register enables/disables port laser shutdown on CAIS insertion condition |
| 1.3.6.1.4.1.20044.38.9.1.1.1.9 | Columnpm1004vdcCfgUpAccessioAlmPortn | read-write | current | CSF contributors on Client Port :This register configures the contributors to upstream CSF insertion on the port. |
| 1.3.6.1.4.1.20044.38.9.1.1.1.10 | Columnpm1004vdcCfgUpMapperDeAlmPortn | read-write | current | CSF contributors on Client Port :This register configures the contributors to upstream CSF insertion on the port. |
| 1.3.6.1.4.1.20044.38.9.1.1.1.17 | Columnpm1004vdcCfgDownAccessioAlmPortn | read-write | current | CAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port. |
| 1.3.6.1.4.1.20044.38.9.1.1.1.18 | Columnpm1004vdcCfgDownMapperDeAlmPortn | read-write | current | CAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port. |
| 1.3.6.1.4.1.20044.38.9.1.1.1.19 | Columnpm1004vdcCfgDownDfrmAlmPortn | read-write | current | CAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port. |
| 1.3.6.1.4.1.20044.38.9.1.1.1.20 | Columnpm1004vdcCfgDownLineSyncAlarmsPortn | read-write | deprecated | CAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port. |
| 1.3.6.1.4.1.20044.38.9.2 | Nodepm1004vdcCfgStartup | |||
| 1.3.6.1.4.1.20044.38.9.2.1 | Tablepm1004vdcCfgClientStartupTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.38.9.2.1.1 | Rowpm1004vdcCfgClientStartupEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.38.9.2.1.1.1 | Columnpm1004vdcCfgClientStartupIndex | read-only | current | Index definition for the clientStartup table |
| 1.3.6.1.4.1.20044.38.9.2.1.1.3 | Columnpm1004vdcCfgSystConfPortPortn | read-write | current | Default Settings on Client Port :This register configures the default initialisation settings on the port. |
| 1.3.6.1.4.1.20044.38.9.2.1.1.4 | Columnpm1004vdcCfgNetConfPortPortn | read-write | current | Default Protocol on Client Port :This register configures the default initialisation protocol on the port. |
| 1.3.6.1.4.1.20044.38.9.2.1.1.5 | Columnpm1004vdcCfgAdddropConfPortPortn | read-write | deprecated | Default Add&Drop mode on Client Port :This register configures the default Add&Drop mode on the port. |
| 1.3.6.1.4.1.20044.38.9.2.2 | Nodepm1004vdctablelineStartup | |||
| 1.3.6.1.4.1.20044.38.9.2.2.2 | Scalarpm1004vdcCfgsystConfLine1 | read-write | current | Default Settings on Line 1 :This register configures the default initialisation settings on Line port 1. |
| 1.3.6.1.4.1.20044.38.9.2.2.5 | Scalarpm1004vdcCfglineOptions1 | read-write | current | Default Options on Active Line Port :This register configures the default options on the active line port |
| 1.3.6.1.4.1.20044.38.9.2.2.6 | Scalarpm1004vdcCfgsystConfLine2 | read-write | current | Default Settings on Line 2 :This register configures the default initialisation settings on Line port 2. |
| 1.3.6.1.4.1.20044.38.9.2.2.7 | Scalarpm1004vdcCfglineSelection | read-write | current | Default Settings of active line :This register configures the start up active line. |
| 1.3.6.1.4.1.20044.38.9.2.2.9 | Scalarpm1004vdcCfglineOptions2 | read-write | current | Default Options on Active Line Port :This register configures the default options on the active line port |
| 1.3.6.1.4.1.20044.38.9.2.3 | Tablepm1004vdcCfgXfpTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.38.9.2.3.1 | Rowpm1004vdcCfgXfpEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.38.9.2.3.1.1 | Columnpm1004vdcCfgXfpIndex | read-only | current | Index definition for the xfp table |
| 1.3.6.1.4.1.20044.38.9.2.3.1.3 | Columnpm1004vdcCfgSystConfXfpPortn | read-write | current | Default settings on XFP Port :This register configures the default initialisation settings on XFP port. |
| 1.3.6.1.4.1.20044.38.9.2.3.1.4 | Columnpm1004vdcCfgDataRateConfXfpPortn | read-write | deprecated | : |
| 1.3.6.1.4.1.20044.38.9.3 | Nodepm1004vdcCfgLabels | |||
| 1.3.6.1.4.1.20044.38.9.3.1 | Tablepm1004vdcCfgLabelclientTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.38.9.3.1.1 | Rowpm1004vdcCfgLabelclientEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.38.9.3.1.1.1 | Columnpm1004vdcCfgLabelclientIndex | read-only | current | Index definition for the labelclient table |
| 1.3.6.1.4.1.20044.38.9.3.1.1.3 | Columnpm1004vdcCfgLabelclientPortn | read-write | current | Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. |
| 1.3.6.1.4.1.20044.38.9.3.2 | Tablepm1004vdcCfgLabellineTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.38.9.3.2.1 | Rowpm1004vdcCfgLabellineEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.38.9.3.2.1.1 | Columnpm1004vdcCfgLabellineIndex | read-only | current | Index definition for the labelline table |
| 1.3.6.1.4.1.20044.38.9.3.2.1.3 | Columnpm1004vdcCfgLabellinePortn | read-write | current | Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. |
| 1.3.6.1.4.1.20044.38.9.4 | Nodepm1004vdcCfgStartupthresholds | |||
| 1.3.6.1.4.1.20044.38.9.4.1 | Tablepm1004vdcCfgClientStartupThreshTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.38.9.4.1.1 | Rowpm1004vdcCfgClientStartupThreshEntry | not-accessible | current | Row definition for the startupthresholds table |
| 1.3.6.1.4.1.20044.38.9.4.1.1.1 | Columnpm1004vdcCfgClientStartupThreshIndex | read-only | current | Index definition for the clientStartupThresh table |
| 1.3.6.1.4.1.20044.38.9.4.1.1.15 | Columnpm1004vdcCfgClientThreshtxpowhighPortn | read-write | current | Default Setting on Tx Power high threshold :This register configures the default initialisation of the high threshold of the Transmit power on the port. |
| 1.3.6.1.4.1.20044.38.9.4.1.1.16 | Columnpm1004vdcCfgClientThreshtxpowlowPortn | read-write | current | Default Setting on Tx Power low threshold :This register configures the default initialisation of the low threshold of the Transmit power on the port. |
| 1.3.6.1.4.1.20044.38.9.4.1.1.19 | Columnpm1004vdcCfgClientThreshrxpowhighPortn | read-write | current | Default Setting on Rx Power high threshold :This register configures the default initialisation of the high threshold of the received power on the port. |
| 1.3.6.1.4.1.20044.38.9.4.1.1.20 | Columnpm1004vdcCfgClientThreshrxpowlowPortn | read-write | current | Default Setting on Rx Power low threshold :This register configures the default initialisation of the low threshold of the received power on the port. |
| 1.3.6.1.4.1.20044.38.9.4.2 | Tablepm1004vdcCfgLineStartupThreshTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.38.9.4.2.1 | Rowpm1004vdcCfgLineStartupThreshEntry | not-accessible | current | Row definition for the startupthresholds table |
| 1.3.6.1.4.1.20044.38.9.4.2.1.1 | Columnpm1004vdcCfgLineStartupThreshIndex | read-only | current | Index definition for the lineStartupThresh table |
| 1.3.6.1.4.1.20044.38.9.4.2.1.15 | Columnpm1004vdcCfgLineThreshtxpowhighPortn | read-write | current | Default Setting on Tx Power high threshold :This register configures the default initialisation of the high threshold of the Transmit power on the line. |
| 1.3.6.1.4.1.20044.38.9.4.2.1.16 | Columnpm1004vdcCfgLineThreshtxpowlowPortn | read-write | current | Default Setting on Tx Power low threshold :This register configures the default initialisation of the low threshold of the Transmit power on the line. |
| 1.3.6.1.4.1.20044.38.9.4.2.1.19 | Columnpm1004vdcCfgLineThreshrxpowhighPortn | read-write | current | Default Setting on Rx Power high threshold :This register configures the default initialisation of the high threshold of the received power on the line. |
| 1.3.6.1.4.1.20044.38.9.4.2.1.20 | Columnpm1004vdcCfgLineThreshrxpowlowPortn | read-write | current | Default Setting on Rx Power low threshold :This register configures the default initialisation of the low threshold of the received power on the line. |
| 1.3.6.1.4.1.20044.38.9.5 | Nodepm1004vdcCfgStartuptlh | |||
| 1.3.6.1.4.1.20044.38.9.5.1 | Tablepm1004vdcCfgOtxtlhTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.38.9.5.1.1 | Rowpm1004vdcCfgOtxtlhEntry | not-accessible | current | Row definition for the startuptlh table |
| 1.3.6.1.4.1.20044.38.9.5.1.1.1 | Columnpm1004vdcCfgOtxtlhIndex | read-only | current | Index definition for the otxtlh table |
| 1.3.6.1.4.1.20044.38.9.5.1.1.3 | Columnpm1004vdcCfgNuPortn | read-write | deprecated | : |
| 1.3.6.1.4.1.20044.38.9.5.1.1.4 | Columnpm1004vdcCfgLineDitherRatePortn | read-write | current | Default Line OTX TLH FM amplitude :This register configures the start-up width of the frequency modulation of the Line OTX TLH |
| 1.3.6.1.4.1.20044.38.9.5.1.1.5 | Columnpm1004vdcCfgLineDitherFhzPortn | read-write | current | Default Line OTX TLH FM frequency :This register configures the start-up frequency of the frequency modulation of the Line OTX TLH |
| 1.3.6.1.4.1.20044.38.9.5.1.1.6 | Columnpm1004vdcCfgLinePwrLaserPortn | read-write | current | Defaut Line OTX TLH output Power :This register configures the start-up output power of the Line OTX TLH (Unit = dBm) |
| 1.3.6.1.4.1.20044.38.9.5.1.1.7 | Columnpm1004vdcCfgLineFCurrentPortn | read-write | current | Default Line OTX TLH Channel :This register configures the start-up laser channel of the Line OTX TLH |
| 1.3.6.1.4.1.20044.38.9.5.1.1.8 | Columnpm1004vdcCfgLineGridCurrentPortn | read-write | current | Default Line OTX TLH Grid :This register configures the start-up laser grid of the Line OTX TLH |
| 1.3.6.1.4.1.20044.38.9.5.1.1.9 | Columnpm1004vdcCfgFPortn | read-write | current | Default Line OTX TLH lowest Freq :This register configures the start-up lowest frequency supported on the Line OTX TLH |
| 1.3.6.1.4.1.20044.38.9.5.1.1.10 | Columnpm1004vdcCfgReservedPortn | read-write | deprecated | : |
| 1.3.6.1.4.1.20044.38.9.5.1.1.11 | Columnpm1004vdcCfgLinePhotodiodeModePortn | read-write | current | Default Line OTX TLH APD mode :This register configures the start-up APD mode of the Line OTX TLH |
| 1.3.6.1.4.1.20044.38.9.5.1.1.12 | Columnpm1004vdcCfgLinePhotodiodeValuePortn | read-write | current | Default Line OTX TLH APD atten. :This register configures the start-up APD attenuation on the Line OTX TLH |
| 1.3.6.1.4.1.20044.38.9.6 | Nodepm1004vdcCfgStartupslotslineaddtx1 | |||
| 1.3.6.1.4.1.20044.38.9.6.1 | Tablepm1004vdcCfgSlotslineaddtx1Table | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.38.9.6.1.1 | Rowpm1004vdcCfgSlotslineaddtx1Entry | not-accessible | current | Row definition for the startupslotslineaddtx1 table |
| 1.3.6.1.4.1.20044.38.9.6.1.1.1 | Columnpm1004vdcCfgSlotslineaddtx1Index | read-only | current | Index definition for the slotslineaddtx1 table |
| 1.3.6.1.4.1.20044.38.9.6.1.1.3 | Columnpm1004vdcCfgLine1Addslotb2PortPortn | read-write | current | Port Defaut Add Slot allocation (MSB) on Line1 :This register configures the start-up slots allocation on the port (MSB) |
| 1.3.6.1.4.1.20044.38.9.6.1.1.4 | Columnpm1004vdcCfgLine1Addslotb1PortPortn | read-write | current | Port Defaut Add Slot allocation (LSB) on Line1 :This register configures the start-up slots allocation on the port (LSB) |
| 1.3.6.1.4.1.20044.38.9.6.1.1.5 | Columnpm1004vdcCfgLine1AddprotocolPortPortn | read-write | current | Port Defaut Protocol on Line1 :This register configures the start-up protocol on the port |
| 1.3.6.1.4.1.20044.38.9.7 | Nodepm1004vdcCfgStartupslotslineaddtx2 | |||
| 1.3.6.1.4.1.20044.38.9.7.1 | Tablepm1004vdcCfgSlotslineaddtx2Table | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.38.9.7.1.1 | Rowpm1004vdcCfgSlotslineaddtx2Entry | not-accessible | current | Row definition for the startupslotslineaddtx2 table |
| 1.3.6.1.4.1.20044.38.9.7.1.1.1 | Columnpm1004vdcCfgSlotslineaddtx2Index | read-only | current | Index definition for the slotslineaddtx2 table |
| 1.3.6.1.4.1.20044.38.9.7.1.1.3 | Columnpm1004vdcCfgLine2Addslotb2PortPortn | read-write | current | Port Defaut Add Slot allocation (MSB) on Line2 :This register configures the start-up slots allocation on the port (MSB) |
| 1.3.6.1.4.1.20044.38.9.7.1.1.4 | Columnpm1004vdcCfgLine2Addslotb1PortPortn | read-write | current | Port Defaut Add Slot allocation (LSB) on Line2 :This register configures the start-up slots allocation on the port (LSB) |
| 1.3.6.1.4.1.20044.38.9.7.1.1.5 | Columnpm1004vdcCfgLine2AddprotocolPortPortn | read-write | current | Port Defaut Protocol on Line2 :This register configures the start-up protocol on the port |
| 1.3.6.1.4.1.20044.38.9.8 | Nodepm1004vdcCfgStartupslotslinepassthroughtx1 | |||
| 1.3.6.1.4.1.20044.38.9.8.1 | Tablepm1004vdcCfgSlotslinepassthroughtx1Table | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.38.9.8.1.1 | Rowpm1004vdcCfgSlotslinepassthroughtx1Entry | not-accessible | current | Row definition for the startupslotslinepassthroughtx1 table |
| 1.3.6.1.4.1.20044.38.9.8.1.1.1 | Columnpm1004vdcCfgSlotslinepassthroughtx1Index | read-only | current | Index definition for the slotslinepassthroughtx1 table |
| 1.3.6.1.4.1.20044.38.9.8.1.1.3 | Columnpm1004vdcCfgLine1Slotb2PassthroughPortn | read-write | current | Port Defaut PassThrough Slot allocation (MSB) on Line1 :This register configures the start-up slots allocation on the port (MSB) |
| 1.3.6.1.4.1.20044.38.9.8.1.1.4 | Columnpm1004vdcCfgLine1Slotb1PassthroughPortn | read-write | current | Port Defaut PassThrough Slot allocation (LSB) on Line1 :This register configures the start-up slots allocation on the port (LSB) |
| 1.3.6.1.4.1.20044.38.9.8.1.1.5 | Columnpm1004vdcCfgLine1ProtocolPassthroughPortn | read-write | current | Port Defaut PassThrough Protocol on Line1 :This register configures the start-up protocol on the port |
| 1.3.6.1.4.1.20044.38.9.9 | Nodepm1004vdcCfgStartupslotslinepassthroughtx2 | |||
| 1.3.6.1.4.1.20044.38.9.9.1 | Tablepm1004vdcCfgSlotslinepassthroughtx2Table | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.38.9.9.1.1 | Rowpm1004vdcCfgSlotslinepassthroughtx2Entry | not-accessible | current | Row definition for the startupslotslinepassthroughtx2 table |
| 1.3.6.1.4.1.20044.38.9.9.1.1.1 | Columnpm1004vdcCfgSlotslinepassthroughtx2Index | read-only | current | Index definition for the slotslinepassthroughtx2 table |
| 1.3.6.1.4.1.20044.38.9.9.1.1.3 | Columnpm1004vdcCfgLine2Slotb2PassthroughPortn | read-write | current | Port Defaut PassThrough Slot allocation (MSB) on Line2 :This register configures the start-up slots allocation on the port (MSB) |
| 1.3.6.1.4.1.20044.38.9.9.1.1.4 | Columnpm1004vdcCfgLine2Slotb1PassthroughPortn | read-write | current | Port Defaut PassThrough Slot allocation (LSB) on Line2 :This register configures the start-up slots allocation on the port (LSB) |
| 1.3.6.1.4.1.20044.38.9.9.1.1.5 | Columnpm1004vdcCfgLine2ProtocolPassthroughPortn | read-write | current | Port Defaut PassThrough Protocol on Line2 :This register configures the start-up protocol on the port |
| 1.3.6.1.4.1.20044.38.9.10 | Nodepm1004vdcCfgStartupslotslinedroprx1 | |||
| 1.3.6.1.4.1.20044.38.9.10.1 | Tablepm1004vdcCfgSlotslinedroprx1Table | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.38.9.10.1.1 | Rowpm1004vdcCfgSlotslinedroprx1Entry | not-accessible | current | Row definition for the startupslotslinedroprx1 table |
| 1.3.6.1.4.1.20044.38.9.10.1.1.1 | Columnpm1004vdcCfgSlotslinedroprx1Index | read-only | current | Index definition for the slotslinedroprx1 table |
| 1.3.6.1.4.1.20044.38.9.10.1.1.3 | Columnpm1004vdcCfgLine1Dropslotb2PortPortn | read-write | current | Port Defaut Drop Slot allocation (MSB) on Line1 :This register configures the start-up slots allocation on the port (MSB) |
| 1.3.6.1.4.1.20044.38.9.10.1.1.4 | Columnpm1004vdcCfgLine1Dropslotb1PortPortn | read-write | current | Port Defaut Drop Slot allocation (LSB) on Line1 :This register configures the start-up slots allocation on the port (LSB) |
| 1.3.6.1.4.1.20044.38.9.10.1.1.5 | Columnpm1004vdcCfgLine1DropprotocolPortPortn | read-write | current | Port Defaut Protocol on Line1 :This register configures the start-up protocol on the port |
| 1.3.6.1.4.1.20044.38.9.11 | Nodepm1004vdcCfgStartupslotslineaddrx2 | |||
| 1.3.6.1.4.1.20044.38.9.11.1 | Tablepm1004vdcCfgSlotslinedroprx2Table | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.38.9.11.1.1 | Rowpm1004vdcCfgSlotslinedroprx2Entry | not-accessible | current | Row definition for the startupslotslineaddrx2 table |
| 1.3.6.1.4.1.20044.38.9.11.1.1.1 | Columnpm1004vdcCfgSlotslinedroprx2Index | read-only | current | Index definition for the slotslinedroprx2 table |
| 1.3.6.1.4.1.20044.38.9.11.1.1.3 | Columnpm1004vdcCfgLine2Dropslotb2PortPortn | read-write | current | Port Defaut Drop Slot allocation (MSB) on Line2 :This register configures the start-up slots allocation on the port (MSB) |
| 1.3.6.1.4.1.20044.38.9.11.1.1.4 | Columnpm1004vdcCfgLine2Dropslotb1PortPortn | read-write | current | Port Defaut Drop Slot allocation (LSB) on Line2 :This register configures the start-up slots allocation on the port (LSB) |
| 1.3.6.1.4.1.20044.38.9.11.1.1.5 | Columnpm1004vdcCfgLine2DropprotocolPortPortn | read-write | current | Port Defaut Protocol on Line2 :This register configures the start-up protocol on the port |
| 1.3.6.1.4.1.20044.38.9.12 | Nodepm1004vdcCfgOther | |||
| 1.3.6.1.4.1.20044.38.9.12.1 | Nodepm1004vdctablemoduleOther | |||
| 1.3.6.1.4.1.20044.38.9.12.1.2 | Scalarpm1004vdcCfgmode | read-write | current | Default settings on Module :This register selects the startup mode of the module |
| 1.3.6.1.4.1.20044.38.9.13 | Nodepm1004vdcCfgStartuptablefive | |||
| 1.3.6.1.4.1.20044.38.9.13.1 | Tablepm1004vdcCfgOtxtlhcapabilitiesTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.38.9.13.1.1 | Rowpm1004vdcCfgOtxtlhcapabilitiesEntry | not-accessible | current | Row definition for the startuptablefive table |
| 1.3.6.1.4.1.20044.38.9.13.1.1.1 | Columnpm1004vdcCfgOtxtlhcapabilitiesIndex | read-only | current | Index definition for the otxtlhcapabilities table |
| 1.3.6.1.4.1.20044.38.9.13.1.1.3 | Columnpm1004vdcCfgComponentTypePortn | read-only | current | Component parameters :This OID defines the component parameters |
| 1.3.6.1.4.1.20044.38.9.13.1.1.4 | Columnpm1004vdcCfgMiscellaneousPortn | read-only | current | Miscellaneous default settings :This OID defines the miscellaneous parameters |
| 1.3.6.1.4.1.20044.38.9.13.1.1.5 | Columnpm1004vdcCfgFirstChannelPortn | read-only | current | Number of the first channel of the component :This OID defines the first channel number of the PM |
| 1.3.6.1.4.1.20044.38.9.13.1.1.6 | Columnpm1004vdcCfgLastChannelPortn | read-only | current | Number of the last channel of the component :This OID defines the last channel number of the PM |
| 1.3.6.1.4.1.20044.38.9.13.1.1.7 | Columnpm1004vdcCfgGridPortn | read-only | current | Grid value of the component :This OID defines the grid of the PM |
| 1.3.6.1.4.1.20044.38.9.257 | Scalarpm1004vdcCfgWriteConfiguration | read-write | current | Write configuration to module:This OID writes the complete configuration to the module |
| 1.3.6.1.4.1.20044.38.10 | Nodepm1004vdctraps | |||
| 1.3.6.1.4.1.20044.38.10.2 | Scalarpm1004vdctrapPortNumber | read-only | current | Last port which generates a trap |
| 1.3.6.1.4.1.20044.38.10.3 | Scalarpm1004vdctrapLineNumber | read-only | current | Last Line which generates a trap |
| 1.3.6.1.4.1.20044.38.10.4 | Scalarpm1004vdctrapBoardNumber | read-only | current | Last module which generates a trap |
| 1.3.6.1.4.1.20044.38.10.30 | Notificationpm1004vdcLineTrapNotUrgentGoesOn | current | Not urgent Line default is activated | |
| 1.3.6.1.4.1.20044.38.10.31 | Notificationpm1004vdcLineTrapNotUrgentGoesOff | current | Not urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.38.10.32 | Notificationpm1004vdcLineTrapUrgentGoesOn | current | Urgent Line default is activated | |
| 1.3.6.1.4.1.20044.38.10.33 | Notificationpm1004vdcLineTrapUrgentGoesOff | current | Urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.38.10.34 | Notificationpm1004vdcLineTrapCritGoesOn | current | Critical Line default is activated | |
| 1.3.6.1.4.1.20044.38.10.35 | Notificationpm1004vdcLineTrapCritGoesOff | current | Critical Line default disappeared | |
| 1.3.6.1.4.1.20044.38.10.40 | Notificationpm1004vdcClientTrapNotUrgentGoesOn | current | Not urgent client default is activated | |
| 1.3.6.1.4.1.20044.38.10.41 | Notificationpm1004vdcClientTrapNotUrgentGoesOff | current | Not urgent client default disappeared | |
| 1.3.6.1.4.1.20044.38.10.42 | Notificationpm1004vdcClientTrapUrgentGoesOn | current | Urgent client default is activated | |
| 1.3.6.1.4.1.20044.38.10.43 | Notificationpm1004vdcClientTrapUrgentGoesOff | current | Urgent client default disappeared | |
| 1.3.6.1.4.1.20044.38.10.44 | Notificationpm1004vdcClientTrapCritGoesOn | current | Critical client default is activated | |
| 1.3.6.1.4.1.20044.38.10.45 | Notificationpm1004vdcClientTrapCritGoesOff | current | Critical client default disappeared | |
| 1.3.6.1.4.1.20044.38.10.50 | Notificationpm1004vdcPowerTrapUrgentGoesOn | current | Urgent power supply default is activated | |
| 1.3.6.1.4.1.20044.38.10.51 | Notificationpm1004vdcPowerTrapUrgentGoesOff | current | Urgent power supply default disappeared | |
| 1.3.6.1.4.1.20044.38.11 | Nodepm1004vdcMonitoring | |||
| 1.3.6.1.4.1.20044.38.11.1 | Nodepm1004vdcMonOther | |||
| 1.3.6.1.4.1.20044.38.11.1.3 | Nodepm1004vdcMonRmon | |||
| 1.3.6.1.4.1.20044.38.11.1.3.359 | Scalarpm1004vdcMonCountersReset | read-write | current | RMON Counters Reset:This OID resets and restarts all the RMON counters |
| 1.3.6.1.4.1.20044.38.11.1.3.360 | Scalarpm1004vdcMonCountersStop | read-write | current | RMON Counters stop:This OID stops all the RMON counters |
| 1.3.6.1.4.1.20044.38.11.2 | Nodepm1004vdcMonClient | |||
| 1.3.6.1.4.1.20044.38.11.2.4 | Nodepm1004vdcMonClientRmonCounter | |||
| 1.3.6.1.4.1.20044.38.11.2.4.16 | Tablepm1004vdcMonupRmonByteCntTable | not-accessible | current | List of pm1004vdcMonupRmonByteCnt Article |
| 1.3.6.1.4.1.20044.38.11.2.4.16.1 | Rowpm1004vdcMonupRmonByteCntEntry | not-accessible | current | Row definition for the pm1004vdcMonupRmonByteCnt table |
| 1.3.6.1.4.1.20044.38.11.2.4.16.1.1 | Columnpm1004vdcMonupRmonByteCntIndex | read-only | current | Index definition for the pm1004vdcMonupRmonByteCnt table |
| 1.3.6.1.4.1.20044.38.11.2.4.16.1.2 | Columnpm1004vdcMonupRmonByteCntValuePortn | read-only | current | Client Input Bytes :This counter is increased each time a data byte is received on the client port <Help> This counter gives the number of bytes received on th… |
| 1.3.6.1.4.1.20044.38.11.2.4.16.1.3 | Columnpm1004vdcMonupRmonByteCntErrorPortn | read-only | current | Bytes Counter Error :This OID when set indicates the Bytes counter value is invalid on clinet port |
| 1.3.6.1.4.1.20044.38.11.2.4.16.1.4 | Columnpm1004vdcMonupRmonByteCntOverloadPortn | read-only | current | Bytes Counter Overload :This OID when set indicates a Bytes counter overload on client port |
| 1.3.6.1.4.1.20044.38.11.2.4.24 | Tablepm1004vdcMonupRmonCrcErrorCntTable | not-accessible | current | List of pm1004vdcMonupRmonCrcErrorCnt Article |
| 1.3.6.1.4.1.20044.38.11.2.4.24.1 | Rowpm1004vdcMonupRmonCrcErrorCntEntry | not-accessible | current | Row definition for the pm1004vdcMonupRmonCrcErrorCnt table |
| 1.3.6.1.4.1.20044.38.11.2.4.24.1.1 | Columnpm1004vdcMonupRmonCrcErrorCntIndex | read-only | current | Index definition for the pm1004vdcMonupRmonCrcErrorCnt table |
| 1.3.6.1.4.1.20044.38.11.2.4.24.1.2 | Columnpm1004vdcMonupRmonCrcErrorCntValuePortn | read-only | current | Client Input CRC Errors :This counter is increased each time a CRC error is detected on the client port <Help> This counter gives the number of CRC Errors rece… |
| 1.3.6.1.4.1.20044.38.11.2.4.24.1.3 | Columnpm1004vdcMonupRmonCrcErrorCntErrorPortn | read-only | current | CRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on clinet port |
| 1.3.6.1.4.1.20044.38.11.2.4.24.1.4 | Columnpm1004vdcMonupRmonCrcErrorCntOverloadPortn | read-only | current | CRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on client port |
| 1.3.6.1.4.1.20044.38.11.2.4.32 | Tablepm1004vdcMonupRmonPacketsCntTable | not-accessible | current | List of pm1004vdcMonupRmonPacketsCnt Article |
| 1.3.6.1.4.1.20044.38.11.2.4.32.1 | Rowpm1004vdcMonupRmonPacketsCntEntry | not-accessible | current | Row definition for the pm1004vdcMonupRmonPacketsCnt table |
| 1.3.6.1.4.1.20044.38.11.2.4.32.1.1 | Columnpm1004vdcMonupRmonPacketsCntIndex | read-only | current | Index definition for the pm1004vdcMonupRmonPacketsCnt table |
| 1.3.6.1.4.1.20044.38.11.2.4.32.1.2 | Columnpm1004vdcMonupRmonPacketsCntValuePortn | read-only | current | Client Input Packets :This counter is increased each time a packet is received on the client port <Help> This counter gives the number of packets received on t… |
| 1.3.6.1.4.1.20044.38.11.2.4.32.1.3 | Columnpm1004vdcMonupRmonPacketsCntErrorPortn | read-only | current | Packets Counter Error :This OID when set indicates the Packets counter value is invalid on clinet port |
| 1.3.6.1.4.1.20044.38.11.2.4.32.1.4 | Columnpm1004vdcMonupRmonPacketsCntOverloadPortn | read-only | current | Packets Counter Overload :This OID when set indicates a Packets counter overload on client port |
| 1.3.6.1.4.1.20044.38.11.2.4.40 | Tablepm1004vdcMonupRmonBroadcastCntTable | not-accessible | current | List of pm1004vdcMonupRmonBroadcastCnt Article |
| 1.3.6.1.4.1.20044.38.11.2.4.40.1 | Rowpm1004vdcMonupRmonBroadcastCntEntry | not-accessible | current | Row definition for the pm1004vdcMonupRmonBroadcastCnt table |
| 1.3.6.1.4.1.20044.38.11.2.4.40.1.1 | Columnpm1004vdcMonupRmonBroadcastCntIndex | read-only | current | Index definition for the pm1004vdcMonupRmonBroadcastCnt table |
| 1.3.6.1.4.1.20044.38.11.2.4.40.1.2 | Columnpm1004vdcMonupRmonBroadcastCntValuePortn | read-only | current | Client Input Broadcast Packets :This counter is increased each time a broadcast packet is received on the client port <Help> This counter gives the number of B… |
| 1.3.6.1.4.1.20044.38.11.2.4.40.1.3 | Columnpm1004vdcMonupRmonBroadcastCntErrorPortn | read-only | current | Broadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on clinet port |
| 1.3.6.1.4.1.20044.38.11.2.4.40.1.4 | Columnpm1004vdcMonupRmonBroadcastCntOverloadPortn | read-only | current | Broadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port |
| 1.3.6.1.4.1.20044.38.11.2.4.48 | Tablepm1004vdcMonupRmonMulticastCntTable | not-accessible | current | List of pm1004vdcMonupRmonMulticastCnt Article |
| 1.3.6.1.4.1.20044.38.11.2.4.48.1 | Rowpm1004vdcMonupRmonMulticastCntEntry | not-accessible | current | Row definition for the pm1004vdcMonupRmonMulticastCnt table |
| 1.3.6.1.4.1.20044.38.11.2.4.48.1.1 | Columnpm1004vdcMonupRmonMulticastCntIndex | read-only | current | Index definition for the pm1004vdcMonupRmonMulticastCnt table |
| 1.3.6.1.4.1.20044.38.11.2.4.48.1.2 | Columnpm1004vdcMonupRmonMulticastCntValuePortn | read-only | current | Client Input Multicast Packets :This counter is increased each time a Multicast packet is received on the client port <Help> This counter gives the number of M… |
| 1.3.6.1.4.1.20044.38.11.2.4.48.1.3 | Columnpm1004vdcMonupRmonMulticastCntErrorPortn | read-only | current | Multicast Counter Error :This OID when set indicates the Multicast counter value is invalid on clinet port |
| 1.3.6.1.4.1.20044.38.11.2.4.48.1.4 | Columnpm1004vdcMonupRmonMulticastCntOverloadPortn | read-only | current | Multicast Counter Overload :This OID when set indicates a Multicast counter overload on client port |
| 1.3.6.1.4.1.20044.38.11.2.4.208 | Tablepm1004vdcMonupLineRmonByteCntTable | not-accessible | current | List of pm1004vdcMonupLineRmonByteCnt Article |
| 1.3.6.1.4.1.20044.38.11.2.4.208.1 | Rowpm1004vdcMonupLineRmonByteCntEntry | not-accessible | current | Row definition for the pm1004vdcMonupLineRmonByteCnt table |
| 1.3.6.1.4.1.20044.38.11.2.4.208.1.1 | Columnpm1004vdcMonupLineRmonByteCntIndex | read-only | current | Index definition for the pm1004vdcMonupLineRmonByteCnt table |
| 1.3.6.1.4.1.20044.38.11.2.4.208.1.2 | Columnpm1004vdcMonupLineRmonByteCntValuePortn | read-only | current | Line Input Bytes :This counter is increased each time a data byte is received on the Line port <Help> This counter gives the number of bytes received on the Li… |
| 1.3.6.1.4.1.20044.38.11.2.4.208.1.3 | Columnpm1004vdcMonupLineRmonByteCntErrorPortn | read-only | current | Bytes Counter Error :This OID when set indicates the Bytes counter value is invalid on line port |
| 1.3.6.1.4.1.20044.38.11.2.4.208.1.4 | Columnpm1004vdcMonupLineRmonByteCntOverloadPortn | read-only | current | Bytes Counter Overload :This OID when set indicates a Bytes counter overload on line port |
| 1.3.6.1.4.1.20044.38.11.2.4.209 | Tablepm1004vdcMonupLineRmonCrcErrorCntTable | not-accessible | current | List of pm1004vdcMonupLineRmonCrcErrorCnt Article |
| 1.3.6.1.4.1.20044.38.11.2.4.209.1 | Rowpm1004vdcMonupLineRmonCrcErrorCntEntry | not-accessible | current | Row definition for the pm1004vdcMonupLineRmonCrcErrorCnt table |
| 1.3.6.1.4.1.20044.38.11.2.4.209.1.1 | Columnpm1004vdcMonupLineRmonCrcErrorCntIndex | read-only | current | Index definition for the pm1004vdcMonupLineRmonCrcErrorCnt table |
| 1.3.6.1.4.1.20044.38.11.2.4.209.1.2 | Columnpm1004vdcMonupLineRmonCrcErrorCntValuePortn | read-only | current | Line Input CRC Errors :This counter is increased each time a CRC error is detected on the Line port <Help> This counter gives the number of CRC Errors received… |
| 1.3.6.1.4.1.20044.38.11.2.4.209.1.3 | Columnpm1004vdcMonupLineRmonCrcErrorCntErrorPortn | read-only | current | CRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on line port |
| 1.3.6.1.4.1.20044.38.11.2.4.209.1.4 | Columnpm1004vdcMonupLineRmonCrcErrorCntOverloadPortn | read-only | current | CRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on line port |
| 1.3.6.1.4.1.20044.38.11.2.4.210 | Tablepm1004vdcMonupLineRmonPacketsCntTable | not-accessible | current | List of pm1004vdcMonupLineRmonPacketsCnt Article |
| 1.3.6.1.4.1.20044.38.11.2.4.210.1 | Rowpm1004vdcMonupLineRmonPacketsCntEntry | not-accessible | current | Row definition for the pm1004vdcMonupLineRmonPacketsCnt table |
| 1.3.6.1.4.1.20044.38.11.2.4.210.1.1 | Columnpm1004vdcMonupLineRmonPacketsCntIndex | read-only | current | Index definition for the pm1004vdcMonupLineRmonPacketsCnt table |
| 1.3.6.1.4.1.20044.38.11.2.4.210.1.2 | Columnpm1004vdcMonupLineRmonPacketsCntValuePortn | read-only | current | Line Input Packets :This counter is increased each time a packet is received on the Line port <Help> This counter gives the number of packets received on the L… |
| 1.3.6.1.4.1.20044.38.11.2.4.210.1.3 | Columnpm1004vdcMonupLineRmonPacketsCntErrorPortn | read-only | current | Packets Counter Error :This OID when set indicates the Packets counter value is invalid on client port |
| 1.3.6.1.4.1.20044.38.11.2.4.210.1.4 | Columnpm1004vdcMonupLineRmonPacketsCntOverloadPortn | read-only | current | Packets Counter Overload :This OID when set indicates a Packets counter overload on line port |
| 1.3.6.1.4.1.20044.38.11.3 | Nodepm1004vdcMonLine | |||
| 1.3.6.1.4.1.20044.38.11.3.4 | Nodepm1004vdcMonLineRmonCounter |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| Pm1004vdcAdjustValue | INTEGER { otxadjustvalue0(0), otxadjustvalue1(1), otxadjustvalue2(2), otxadjustvalue3(3), otxadjustvalue4(4), otxadjustvalue5(5), otxadjustvalue6(6), otxadjustvalue7(7), otxadjustvalue8(8), otxadjustvalue9(9), otxadjustvalue10(10) } | current | Different values in Adjust mode on OTX-TLH on client and line ports |
| Pm1004vdcClientOosMode | INTEGER { clientportis(0), clienttxoos(1), clientrxoos(2), clientportoos(3) } | current | Mode for OOS on client ports |
| Pm1004vdcDccMode | INTEGER { dccNo(0), dcctermLine1(1), dcctermLine2(2), dcctermLines12(3), dccmaster(4), dccslaveLine12(7) } | current | Mode for DCC |
| Pm1004vdcModeAddDrop | INTEGER { singleSplitSelect(256) } | current | different mode for client |
| Pm1004vdcModeTimeSlot | INTEGER { singleSplitSelect(256) } | current | different mode for time slot |
| Pm1004vdcOtxChannel | INTEGER | current | Channel selection on OTX-TLH on client and line ports |
| Pm1004vdcOtxGrid | INTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50) } | current | Different grids on OTX-TLH on client and line ports |
| Pm1004vdcOtxMode | INTEGER { otx80mode(1), otx60mode(2), otxadjustmode(4) } | current | Different modes on OTX-TLH on client and line ports |
| Pm1004vdcProtectionStartUp | INTEGER { auto(2), manualX2Line2(0), manualX1Line1(1) } | current | protection for startup |
| Pm1004vdcProtectionTimeSlot | INTEGER { auto(0), manualX2Line2(257), manualX1Line1(513) } | current | protection for control |