OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.29IdentitymodulePm1004mCreation
1.3.6.1.4.1.20044.29.2Nodepm1004malarms
1.3.6.1.4.1.20044.29.2.1Nodepm1004mAlmOther
1.3.6.1.4.1.20044.29.2.1.1Nodepm1004mAlmOtherNurg
1.3.6.1.4.1.20044.29.2.1.1.2Nodepm1004mAlmsynthAlm2
1.3.6.1.4.1.20044.29.2.1.1.2.1Scalarpm1004mAlmConfTableSaveread-onlycurrentPM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> other…
1.3.6.1.4.1.20044.29.2.1.1.2.2Scalarpm1004mAlmInvUploadread-onlycurrentInventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> other (1) <Alarmtype> other (1) <Polarit…
1.3.6.1.4.1.20044.29.2.1.1.2.3Scalarpm1004mAlmConfTableLoadread-onlycurrentPM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> other (1) <Alarmt…
1.3.6.1.4.1.20044.29.2.1.1.2.4Scalarpm1004mAlmCorrelatOffread-onlycurrentNot Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> other (1) <Alarmtype> other (1) <Pol…
1.3.6.1.4.1.20044.29.2.1.1.2.5Scalarpm1004mAlmMaintenanceOnread-onlycurrentMaintenance Mode :This OID indicates that the PM is in maintenance mode. <Help> This alarm indicates that the maintenance mode is enabled on the PM <Condtype> …
1.3.6.1.4.1.20044.29.2.1.2Nodepm1004mAlmOtherUrg
1.3.6.1.4.1.20044.29.2.1.2.194Nodepm1004mAlmmodInitFailLevel2
1.3.6.1.4.1.20044.29.2.1.2.194.1Scalarpm1004mAlmLedFailread-onlycurrentLed Fail :This OID indicates that Led register has not been correctly initalized <Help> This alarm indicates if the module LEDs are correctly initialized <Cond…
1.3.6.1.4.1.20044.29.2.1.2.194.2Scalarpm1004mAlmNextColdBootForcedread-onlycurrentNext Cold Boot Forced :This OID indicates that the next Reset will be forced Cold <Help> This alarm indicates that the next reset of the module will be forced …
1.3.6.1.4.1.20044.29.2.1.2.194.3Scalarpm1004mAlmBootUndoneread-onlycurrentBoot Undone :This OID indicates that the boot has not been correctly achieved <Help> This alarm indicates if the module has correctly boot <Condtype> BOOT_UNDO…
1.3.6.1.4.1.20044.29.2.1.2.194.4Scalarpm1004mAlmResetHwInitFailread-onlycurrentReset HW Init Fail :This OID indicates that the HW intialization has caused unknown intial conditions <Help> This alarm indicates if the HW has been correctly …
1.3.6.1.4.1.20044.29.2.1.2.194.5Scalarpm1004mAlmSwInitFailread-onlycurrentSW Init Fail :This OID indicates that the SW intialization has caused unknown intial conditions <Help> This alarm indicates if the SW module is correctly initi…
1.3.6.1.4.1.20044.29.2.1.2.195Nodepm1004mAlmmodInitFailLevel3
1.3.6.1.4.1.20044.29.2.1.2.195.1Scalarpm1004mAlmGwIdentFailread-onlycurrentGW Ident Fail :This OID indicates that GW identification has not been read <Help> This alarm indicates if the GW has been correctly identified <Condtype> GW_ID…
1.3.6.1.4.1.20044.29.2.1.2.195.2Scalarpm1004mAlmObmTypeReadFailread-onlycurrentOBM Type Read Fail :This OID indicates that OBM type has not been recognized <Help> This alarm indicates if the OBM board has been correctly identified <Condty…
1.3.6.1.4.1.20044.29.2.1.2.195.3Scalarpm1004mAlmInitModuleFailread-onlycurrentInit Module Fail :This OID indicates that the Module has not been correctly initialized <Help> This alarm indicates if the SW module is correctly initialized <…
1.3.6.1.4.1.20044.29.2.1.2.195.5Scalarpm1004mAlmXfp1InitFailread-onlycurrentXFP1 Init Fail :This OID indicates that the XFP has not been correctly initialized <Help> This alarm indicates if the line transceiver 1 is correctly initializ…
1.3.6.1.4.1.20044.29.2.1.2.195.6Scalarpm1004mAlmXfp2InitFailread-onlycurrentXFP2 Init Fail :This OID indicates that the XFP has not been correctly initialized <Help> This alarm indicates if the line transceiver 2 is correctly initializ…
1.3.6.1.4.1.20044.29.2.1.2.195.7Scalarpm1004mAlmLine1InitFailread-onlycurrentLine1 Init Fail :This OID indicates that the Line registersvsubset has not been correctly initialized <Help> This alarm indicates if the line port 1 is correct…
1.3.6.1.4.1.20044.29.2.1.2.195.8Scalarpm1004mAlmLine2InitFailread-onlycurrentLine2 Init Fail :This OID indicates that the Line register subset has not been correctly initialized <Help> This alarm indicates if the line port 2 is correctl…
1.3.6.1.4.1.20044.29.2.1.2.195.9Scalarpm1004mAlmClient1InitFailread-onlycurrentClient1 Init Fail :This OID indicates that Client 1 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 1 is cor…
1.3.6.1.4.1.20044.29.2.1.2.195.10Scalarpm1004mAlmClient2InitFailread-onlycurrentClient2 Init Fail :This OID indicates that Client 2 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 2 is cor…
1.3.6.1.4.1.20044.29.2.1.2.195.11Scalarpm1004mAlmClient3InitFailread-onlycurrentClient3 Init Fail :This OID indicates that Client 3 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 3 is cor…
1.3.6.1.4.1.20044.29.2.1.2.195.12Scalarpm1004mAlmClient4InitFailread-onlycurrentClient4 Init Fail :This OID indicates that Client 4 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 4 is cor…
1.3.6.1.4.1.20044.29.2.1.3Nodepm1004mAlmOtherCrit
1.3.6.1.4.1.20044.29.2.1.3.0Nodepm1004mAlmsynthAlm0
1.3.6.1.4.1.20044.29.2.1.3.0.9Scalarpm1004mAlmModGlobFailread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the PM <Condtype> MOD_GLOB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> sy…
1.3.6.1.4.1.20044.29.2.1.3.0.15Scalarpm1004mAlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.29.2.1.3.0.16Scalarpm1004mAlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.29.2.2Nodepm1004mAlmClient
1.3.6.1.4.1.20044.29.2.2.1Nodepm1004mAlmClientNurg
1.3.6.1.4.1.20044.29.2.2.1.48Tablepm1004mAlmsfpWarnDdmTablenot-accessiblecurrentList of pm1004mAlmsfpWarnDdm Article
1.3.6.1.4.1.20044.29.2.2.1.48.1Rowpm1004mAlmsfpWarnDdmEntrynot-accessiblecurrentRow definition for the pm1004mAlmsfpWarnDdm table
1.3.6.1.4.1.20044.29.2.2.1.48.1.1Columnpm1004mAlmsfpWarnDdmIndexread-onlycurrentIndex definition for the pm1004mAlmsfpWarnDdm table
1.3.6.1.4.1.20044.29.2.2.1.48.1.2Columnpm1004mAlmTxPwLowWngPortnread-onlycurrentClient SFP Tx Power Low Warning :Warning indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> TX…
1.3.6.1.4.1.20044.29.2.2.1.48.1.3Columnpm1004mAlmTxPwrHighWngPortnread-onlycurrentClient SFP Tx Power High Warning :Warning indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.29.2.2.1.48.1.4Columnpm1004mAlmTxBiasLowWngPortnread-onlycurrentClient SFP Bias Low Warning :Warning indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.29.2.2.1.48.1.5Columnpm1004mAlmTxBiasHighWngPortnread-onlycurrentClient SFP Bias High Warning :Warning indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.29.2.2.1.48.1.6Columnpm1004mAlmVccLowWngPortnread-onlycurrentClient SFP Power Supply Low Warning :Warning indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.29.2.2.1.48.1.7Columnpm1004mAlmVccHighWngPortnread-onlycurrentClient SFP Power Supply High Warning :Warning indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condty…
1.3.6.1.4.1.20044.29.2.2.1.48.1.8Columnpm1004mAlmTempLowWngPortnread-onlycurrentClient SFP Temp Low Warning :Warning indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> TEMP_LO…
1.3.6.1.4.1.20044.29.2.2.1.48.1.9Columnpm1004mAlmTempHighWngPortnread-onlycurrentClient SFP Temp High Warning :Warning indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> TEMP_…
1.3.6.1.4.1.20044.29.2.2.1.48.1.16Columnpm1004mAlmRxPwrLowWngPortnread-onlycurrentClient SFP Rx Power Low Warning :Warning indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> RX_…
1.3.6.1.4.1.20044.29.2.2.1.48.1.17Columnpm1004mAlmRxPwrHighWngPortnread-onlycurrentClient SFP Rx Power High Warning :Warning indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> R…
1.3.6.1.4.1.20044.29.2.2.1.96Tablepm1004mAlmk1K2ClientTablenot-accessiblecurrentList of pm1004mAlmk1K2Client Article
1.3.6.1.4.1.20044.29.2.2.1.96.1Rowpm1004mAlmk1K2ClientEntrynot-accessiblecurrentRow definition for the pm1004mAlmk1K2Client table
1.3.6.1.4.1.20044.29.2.2.1.96.1.1Columnpm1004mAlmk1K2ClientIndexread-onlycurrentIndex definition for the pm1004mAlmk1K2Client table
1.3.6.1.4.1.20044.29.2.2.1.96.1.2Columnpm1004mAlmk1K2ClientPortnread-onlycurrentClient K1-K2 Extracted Value :This OID gives the value of K1 (LSB) and K2 (MSB) extracted from the overhead of the received OC-48c/STM-16c signal <Condtype> CL…
1.3.6.1.4.1.20044.29.2.2.2Nodepm1004mAlmClientUrg
1.3.6.1.4.1.20044.29.2.2.2.32Tablepm1004mAlmsfpAlmDdmTablenot-accessiblecurrentList of pm1004mAlmsfpAlmDdm Article
1.3.6.1.4.1.20044.29.2.2.2.32.1Rowpm1004mAlmsfpAlmDdmEntrynot-accessiblecurrentRow definition for the pm1004mAlmsfpAlmDdm table
1.3.6.1.4.1.20044.29.2.2.2.32.1.1Columnpm1004mAlmsfpAlmDdmIndexread-onlycurrentIndex definition for the pm1004mAlmsfpAlmDdm table
1.3.6.1.4.1.20044.29.2.2.2.32.1.2Columnpm1004mAlmTxPwrLowAlaPortnread-onlycurrentClient SFP Tx Power Low :Alarm indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> TX_PWR_LOW_A…
1.3.6.1.4.1.20044.29.2.2.2.32.1.3Columnpm1004mAlmTxPwrHighAlaPortnread-onlycurrentClient SFP Tx Power High :Alarm indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> TX_PWR_HIG…
1.3.6.1.4.1.20044.29.2.2.2.32.1.4Columnpm1004mAlmTxBiasLowAlaPortnread-onlycurrentClient SFP Bias Low :Alarm indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> TX_BIAS_LO…
1.3.6.1.4.1.20044.29.2.2.2.32.1.5Columnpm1004mAlmTxBiasHighAlaPortnread-onlycurrentClient SFP Bias High :Alarm indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype> TX_BIAS_…
1.3.6.1.4.1.20044.29.2.2.2.32.1.6Columnpm1004mAlmVccLowAlaPortnread-onlycurrentClient SFP Power Supply Low :Alarm indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype> VCC_LOW_…
1.3.6.1.4.1.20044.29.2.2.2.32.1.7Columnpm1004mAlmVccHighAlaPortnread-onlycurrentClient SFP Power Supply High :Alarm indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condtype> VCC_HI…
1.3.6.1.4.1.20044.29.2.2.2.32.1.8Columnpm1004mAlmTempLowAlaPortnread-onlycurrentClient SFP Temp Low :Alarm indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> TEMP_LOW_ALA_1 <P…
1.3.6.1.4.1.20044.29.2.2.2.32.1.9Columnpm1004mAlmTempHighAlaPortnread-onlycurrentClient SFP Temp High :Alarm indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> TEMP_HIGH_ALA_1…
1.3.6.1.4.1.20044.29.2.2.2.32.1.16Columnpm1004mAlmRxPwrLowAlaPortnread-onlycurrentClient SFP Rx Power Low :Alarm indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> RX_PWR_LOW_AL…
1.3.6.1.4.1.20044.29.2.2.2.32.1.17Columnpm1004mAlmRxPwrHighAlaPortnread-onlycurrentClient SFP Rx Power High :Alarm indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> RX_PWR_HIGH…
1.3.6.1.4.1.20044.29.2.2.3Nodepm1004mAlmClientCrit
1.3.6.1.4.1.20044.29.2.2.3.8Tablepm1004mAlmsynthAlmPortTablenot-accessiblecurrentList of pm1004mAlmsynthAlmPort Article
1.3.6.1.4.1.20044.29.2.2.3.8.1Rowpm1004mAlmsynthAlmPortEntrynot-accessiblecurrentRow definition for the pm1004mAlmsynthAlmPort table
1.3.6.1.4.1.20044.29.2.2.3.8.1.1Columnpm1004mAlmsynthAlmPortIndexread-onlycurrentIndex definition for the pm1004mAlmsynthAlmPort table
1.3.6.1.4.1.20044.29.2.2.3.8.1.2Columnpm1004mAlmSfpAbsentPortnread-onlycurrentClient SFP Absent :This OID indicates that the SFP module is not present in the client port. <Help> This alarm indicates if the client transceiver is present. …
1.3.6.1.4.1.20044.29.2.2.3.8.1.3Columnpm1004mAlmDdmAbsentPortnread-onlycurrentDDM Supported On Client SFP :This OID indicates that the Client SFP module supports the Digital Diagnostic Monitoring function <Help> This status indicates if …
1.3.6.1.4.1.20044.29.2.2.3.8.1.5Columnpm1004mAlmHwFailAccPortnread-onlycurrentClient HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Condtype> HW_FAIL_ACC_1 <Probcause> equipmentMalfunction (16)…
1.3.6.1.4.1.20044.29.2.2.3.8.1.6Columnpm1004mAlmDwLsdPortnread-onlycurrentClient SFP Laser Shutdown :This OID indicates the Client SFP transmitter output is ON. <Help> This status indicates if the client transceiver laser is ON or OF…
1.3.6.1.4.1.20044.29.2.2.3.8.1.7Columnpm1004mAlmClientLocalOosPortnread-onlycurrentLocal Client Port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local c…
1.3.6.1.4.1.20044.29.2.2.3.8.1.8Columnpm1004mAlmClientRemoteOosPortnread-onlycurrentRemote Client Port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the remot…
1.3.6.1.4.1.20044.29.2.2.3.8.1.9Columnpm1004mAlmDwCaisPortnread-onlycurrentClient AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indicates if a Client Alarm Indication Signal is…
1.3.6.1.4.1.20044.29.2.2.3.8.1.10Columnpm1004mAlmSfpDdmWarningPortnread-onlycurrentWarning On Client SFP DDM :This OID indicates a warning is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Warning has been detecte…
1.3.6.1.4.1.20044.29.2.2.3.8.1.11Columnpm1004mAlmSfpDdmAlmPortnread-onlycurrentAlarm On Client SFP DDM :This OID indicates an alarm is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Alarm has been detected on …
1.3.6.1.4.1.20044.29.2.2.3.8.1.13Columnpm1004mAlmFailAccPortnread-onlycurrentClient Access Fail :This OID indicates a failure on the Client port <Condtype> FAIL_ACC_1 <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12)…
1.3.6.1.4.1.20044.29.2.2.3.8.1.17Columnpm1004mAlmUpCsfPortnread-onlycurrentClient Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu…
1.3.6.1.4.1.20044.29.2.2.3.16Tablepm1004mAlmaccessioAlmTablenot-accessiblecurrentList of pm1004mAlmaccessioAlm Article
1.3.6.1.4.1.20044.29.2.2.3.16.1Rowpm1004mAlmaccessioAlmEntrynot-accessiblecurrentRow definition for the pm1004mAlmaccessioAlm table
1.3.6.1.4.1.20044.29.2.2.3.16.1.1Columnpm1004mAlmaccessioAlmIndexread-onlycurrentIndex definition for the pm1004mAlmaccessioAlm table
1.3.6.1.4.1.20044.29.2.2.3.16.1.2Columnpm1004mAlmDwLasFailPortnread-onlycurrentClient SFP Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the client port (this alarm reports the transmitter failure alarm …
1.3.6.1.4.1.20044.29.2.2.3.16.1.5Columnpm1004mAlmUpLosPortnread-onlycurrentClient Input Loss Of Signal :This OID indicates that no signal is present on the SFP of the client port <Help> This alarm indicates if an optical signal is det…
1.3.6.1.4.1.20044.29.2.2.3.72Tablepm1004mAlmmapperDeAlmTablenot-accessiblecurrentList of pm1004mAlmmapperDeAlm Article
1.3.6.1.4.1.20044.29.2.2.3.72.1Rowpm1004mAlmmapperDeAlmEntrynot-accessiblecurrentRow definition for the pm1004mAlmmapperDeAlm table
1.3.6.1.4.1.20044.29.2.2.3.72.1.1Columnpm1004mAlmmapperDeAlmIndexread-onlycurrentIndex definition for the pm1004mAlmmapperDeAlm table
1.3.6.1.4.1.20044.29.2.2.3.72.1.2Columnpm1004mAlmUpAccOosPortnread-onlycurrentClient Loss Of Frame :This OID indicates the upstream client input port is in Loss of Frame condition <Help> This alarm indicates if there is a Loss of Frame i…
1.3.6.1.4.1.20044.29.2.2.3.72.1.11Columnpm1004mAlmUpBufferOvlPortnread-onlycurrentClient Upstream Buffer Overload :This OID indicates that the rate adaptation buffer for client port is in overload. <Help> This alarm indicates if there is a u…
1.3.6.1.4.1.20044.29.2.2.3.72.1.12Columnpm1004mAlmDwCsfDetPortnread-onlycurrentClient Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client…
1.3.6.1.4.1.20044.29.2.2.3.72.1.15Columnpm1004mAlmDwBufferOvlPortnread-onlycurrentClient Downstream Buffer Overload :This OID indicates that the de-mapper buffer for client port is in overload. <Help> This alarm indicates if there is a downs…
1.3.6.1.4.1.20044.29.2.2.3.104Tablepm1004mAlmaccessioSdhAlarmTablenot-accessiblecurrentList of pm1004mAlmaccessioSdhAlarm Article
1.3.6.1.4.1.20044.29.2.2.3.104.1Rowpm1004mAlmaccessioSdhAlarmEntrynot-accessiblecurrentRow definition for the pm1004mAlmaccessioSdhAlarm table
1.3.6.1.4.1.20044.29.2.2.3.104.1.1Columnpm1004mAlmaccessioSdhAlarmIndexread-onlycurrentIndex definition for the pm1004mAlmaccessioSdhAlarm table
1.3.6.1.4.1.20044.29.2.2.3.104.1.3Columnpm1004mAlmFifoErrPortnread-onlycurrentClient Transceiver Fifo Error :This OID indicates that an error has been detected in the FIFO of the client transceiver <Condtype> FIFO_ERR_1 <Probcause> trans…
1.3.6.1.4.1.20044.29.2.2.3.104.1.4Columnpm1004mAlmRxLossOfLockPortnread-onlycurrentClient Rx Clock Lock Error :This OID indicates the recovered receive clock of the client transceiver is not locked <Condtype> RX_LOSS_OF_LOCK_1 <Probcause> rec…
1.3.6.1.4.1.20044.29.2.2.3.104.1.5Columnpm1004mAlmTxLossOfLockPortnread-onlycurrentClient Tx Clock Lock Error :This OID indicates that the transmit clock of the client transceiver is not locke <Condtype> TX_LOSS_OF_LOCK_1 <Probcause> transmit…
1.3.6.1.4.1.20044.29.2.2.3.104.1.6Columnpm1004mAlmClientAisDetPortnread-onlycurrentClient MS-AIS :This OID indicates that a MS-AIS has been detected on the client input stream <Help> This alarm indicates if there is a MS-AIS/L-AIS is detected…
1.3.6.1.4.1.20044.29.2.2.3.104.1.7Columnpm1004mAlmClientRdiDetPortnread-onlycurrentClient MS-RDI :This OID indicates that a MS-RDI has been detected on the client input stream <Help> This alarm indicates if there is a MS-RDI/L-RDI is detected…
1.3.6.1.4.1.20044.29.2.2.3.104.1.8Columnpm1004mAlmClientOofPortnread-onlycurrentClient Out Of Frame :This OID indicates that an Out Of Frame condition has been detected on the OC-48/STM-16 client input stream <Help> This alarm indicates if…
1.3.6.1.4.1.20044.29.2.3Nodepm1004mAlmLine
1.3.6.1.4.1.20044.29.2.3.1Nodepm1004mAlmLineNurg
1.3.6.1.4.1.20044.29.2.3.1.209Tablepm1004mAlmlineXfp1WarningsTablenot-accessiblecurrentList of pm1004mAlmlineXfp1Warnings Article
1.3.6.1.4.1.20044.29.2.3.1.209.1Rowpm1004mAlmlineXfp1WarningsEntrynot-accessiblecurrentRow definition for the pm1004mAlmlineXfp1Warnings table
1.3.6.1.4.1.20044.29.2.3.1.209.1.1Columnpm1004mAlmlineXfp1WarningsIndexread-onlycurrentIndex definition for the pm1004mAlmlineXfp1Warnings table
1.3.6.1.4.1.20044.29.2.3.1.209.1.2Columnpm1004mAlmTxPowerLowWarningPortnread-onlycurrentLine Optical Tx Power Low Warning :Warning indicating that the XFP/OTX transmitter transmitter output power is lower than the threshold value written in the XF…
1.3.6.1.4.1.20044.29.2.3.1.209.1.3Columnpm1004mAlmTxPowerHighWarningPortnread-onlycurrentLine Optical Tx Power High Warning :Warning indicating that the XFP/OTX transmitter transmitter output power is higher than the threshold value written in the …
1.3.6.1.4.1.20044.29.2.3.1.209.1.4Columnpm1004mAlmTxBiasLowWarningPortnread-onlycurrentLine Transceiver Bias Low Warning :Warning indicating that the XFP/OTX transmitter laser bias current is lower than the threshold value written in the XFP/OTX …
1.3.6.1.4.1.20044.29.2.3.1.209.1.5Columnpm1004mAlmTxBiasHighWarningPortnread-onlycurrentLine Transceiver Bias High Warning :Warning indicating that the XFP/OTX transmitter laser bias current is higher than the threshold value written in the XFP EE…
1.3.6.1.4.1.20044.29.2.3.1.209.1.8Columnpm1004mAlmTempLowWarningPortnread-onlycurrentLine Transceiver Temp Low Warning :Warning indicating that the XFP/OTX temperature is lower than the threshold value written in the XFP/OTX EEPROM <Condtype> T…
1.3.6.1.4.1.20044.29.2.3.1.209.1.9Columnpm1004mAlmTempHighWarningPortnread-onlycurrentLine Transceiver Temp High Warning :Warning indicating that the XFP/OTX temperature is higher than the threshold value written in the XFP EEPROM <Condtype> TEM…
1.3.6.1.4.1.20044.29.2.3.1.209.1.16Columnpm1004mAlmRxPowerLowWarningPortnread-onlycurrentLine Optical Rx Power Low Warning :Warning indicating that the XFP received optical power is lower than the threshold value written in the XFP EEPROM <Condtype…
1.3.6.1.4.1.20044.29.2.3.1.209.1.17Columnpm1004mAlmRxPowerHighWarningPortnread-onlycurrentLine Optical Rx Power High Warning :Warning indicating that the XFP received optical power is higher than the threshold value written in the XFP EEPROM <Condty…
1.3.6.1.4.1.20044.29.2.3.1.225Tablepm1004mAlmlineOtx1TlhWarningsTablenot-accessiblecurrentList of pm1004mAlmlineOtx1TlhWarnings Article
1.3.6.1.4.1.20044.29.2.3.1.225.1Rowpm1004mAlmlineOtx1TlhWarningsEntrynot-accessiblecurrentRow definition for the pm1004mAlmlineOtx1TlhWarnings table
1.3.6.1.4.1.20044.29.2.3.1.225.1.1Columnpm1004mAlmlineOtx1TlhWarningsIndexread-onlycurrentIndex definition for the pm1004mAlmlineOtx1TlhWarnings table
1.3.6.1.4.1.20044.29.2.3.1.225.1.6Columnpm1004mAlmLineModulatorAgingHighWarningPortnread-onlycurrentLine Modulator Aging High Warning :Warning indicating the Line OTX TLH modulator aging is higher than the threshold written in the EEPROM <Condtype> LINE_MODUL…
1.3.6.1.4.1.20044.29.2.3.1.225.1.7Columnpm1004mAlmLineAgingHighWarningPortnread-onlycurrentLine OTX TLH Aging High Warning :Warning indicating the Line OTX TLH aging is higher than the threshold written in the EEPROM <Condtype> LINE_AGING_HIGH_WARNIN…
1.3.6.1.4.1.20044.29.2.3.1.225.1.13Columnpm1004mAlmLineFreqDevHighWarningPortnread-onlycurrentLine Freq. Deviation High Warning :Warning indicating the Line OTX TLH frequency deviation is higher than the threshold written in the EEPROM <Condtype> LINE_F…
1.3.6.1.4.1.20044.29.2.3.1.225.1.15Columnpm1004mAlmLineLaserTempHighWarningPortnread-onlycurrentLine Laser Temp. High Warning :Warning indicating the Line OTX TLH laser temperature is higher than the threshold written in the EEPROM <Condtype> LINE_LASER_T…
1.3.6.1.4.1.20044.29.2.3.2Nodepm1004mAlmLineUrg
1.3.6.1.4.1.20044.29.2.3.2.129Tablepm1004mAlmdfrmBerTablenot-accessiblecurrentList of pm1004mAlmdfrmBer Article
1.3.6.1.4.1.20044.29.2.3.2.129.1Rowpm1004mAlmdfrmBerEntrynot-accessiblecurrentRow definition for the pm1004mAlmdfrmBer table
1.3.6.1.4.1.20044.29.2.3.2.129.1.1Columnpm1004mAlmdfrmBerIndexread-onlycurrentIndex definition for the pm1004mAlmdfrmBer table
1.3.6.1.4.1.20044.29.2.3.2.129.1.2Columnpm1004mAlmLineSignalDegradePortnread-onlycurrentCustom Line Signal Degrade :This OID indicates that the line input signal is DEGRADE. The assertion hysteresis can customized by the host <Condtype> LINE_SIGNA…
1.3.6.1.4.1.20044.29.2.3.2.129.1.3Columnpm1004mAlmLineSignalFailPortnread-onlycurrentCustom Line Signal Fail :This OID indicates that the line input signal is FAIL. The assertion hysteresis can be customized by the host <Condtype> LINE_SIGNAL_F…
1.3.6.1.4.1.20044.29.2.3.2.129.1.6Columnpm1004mAlmLineDegradePortnread-onlycurrentFixed Line Signal Degrade :This OID indicates that the line input signal is DEGRADE. The assetion hysteresis is fixed to 10-8 (assertion) and 10-9 (de-assertio…
1.3.6.1.4.1.20044.29.2.3.2.208Tablepm1004mAlmlineXfp1AlarmTablenot-accessiblecurrentList of pm1004mAlmlineXfp1Alarm Article
1.3.6.1.4.1.20044.29.2.3.2.208.1Rowpm1004mAlmlineXfp1AlarmEntrynot-accessiblecurrentRow definition for the pm1004mAlmlineXfp1Alarm table
1.3.6.1.4.1.20044.29.2.3.2.208.1.1Columnpm1004mAlmlineXfp1AlarmIndexread-onlycurrentIndex definition for the pm1004mAlmlineXfp1Alarm table
1.3.6.1.4.1.20044.29.2.3.2.208.1.2Columnpm1004mAlmTxPowerLowAlarmPortnread-onlycurrentLine Optical Tx Power Low :Alarm indicating that the XFP/OTX transmitter transmitter output power is lower than the threshold value written in the XFP/OTX EEPR…
1.3.6.1.4.1.20044.29.2.3.2.208.1.3Columnpm1004mAlmTxPowerHighAlarmPortnread-onlycurrentLine Optical Tx Power High :Alarm indicating that the XFP/OTX transmitter transmitter output power is higher than the threshold value written in the XFP EEPROM…
1.3.6.1.4.1.20044.29.2.3.2.208.1.4Columnpm1004mAlmTxBiasLowAlarmPortnread-onlycurrentLine Transceiver Bias Low :Alarm indicating that the XFP/OTX transmitter laser bias current is lower than the threshold value written in the XFP/OTX EEPROM <Co…
1.3.6.1.4.1.20044.29.2.3.2.208.1.5Columnpm1004mAlmTxBiasHighAlarmPortnread-onlycurrentLine Transceiver Bias High :Alarm indicating that the XFP/OTX transmitter laser bias current is higher than the threshold value written in the XFP EEPROM <Cond…
1.3.6.1.4.1.20044.29.2.3.2.208.1.8Columnpm1004mAlmTempLowAlarmPortnread-onlycurrentLine Transceiver Temp Low :Alarm indicating that the XFP/OTX temperature is lower than the threshold value written in the XFP/OTX EEPROM <Condtype> TEMP_LOW_AL…
1.3.6.1.4.1.20044.29.2.3.2.208.1.9Columnpm1004mAlmTempHighAlarmPortnread-onlycurrentLine Transceiver Temp High :Alarm indicating that the XFP/OTX temperature is higher than the threshold value written in the XFP EEPROM <Condtype> TEMP_HIGH_ALA…
1.3.6.1.4.1.20044.29.2.3.2.208.1.16Columnpm1004mAlmRxPowerLowAlarmPortnread-onlycurrentLine Optical Rx Power Low :Alarm indicating that the XFP received optical power is lower than the threshold value written in the XFP EEPROM <Condtype> RX_POWER…
1.3.6.1.4.1.20044.29.2.3.2.208.1.17Columnpm1004mAlmRxPowerHighAlarmPortnread-onlycurrentLine Optical Rx Power High :Alarm indicating that the XFP received optical power is higher than the threshold value written in the XFP EEPROM <Condtype> RX_POW…
1.3.6.1.4.1.20044.29.2.3.2.212Tablepm1004mAlmlineXfp1SupplyAlarmTablenot-accessiblecurrentList of pm1004mAlmlineXfp1SupplyAlarm Article
1.3.6.1.4.1.20044.29.2.3.2.212.1Rowpm1004mAlmlineXfp1SupplyAlarmEntrynot-accessiblecurrentRow definition for the pm1004mAlmlineXfp1SupplyAlarm table
1.3.6.1.4.1.20044.29.2.3.2.212.1.1Columnpm1004mAlmlineXfp1SupplyAlarmIndexread-onlycurrentIndex definition for the pm1004mAlmlineXfp1SupplyAlarm table
1.3.6.1.4.1.20044.29.2.3.2.212.1.2Columnpm1004mAlmVee5LowAlarmPortnread-onlycurrentVEE5 Power Supply Low :Alarm indicating the XFP/OTX VEE5 power supply is lower than the threshold written in the EEPROM <Condtype> VEE5_LOW_ALARM_1 <Probcause>…
1.3.6.1.4.1.20044.29.2.3.2.212.1.3Columnpm1004mAlmVee5HighAlarmPortnread-onlycurrentVEE5 Power Supply High :Alarm indicating the XFP/OTX VEE5 power supply is higher than the threshold written in the EEPROM <Condtype> VEE5_HIGH_ALARM_1 <Probcau…
1.3.6.1.4.1.20044.29.2.3.2.212.1.4Columnpm1004mAlmVcc2LowAlarmPortnread-onlycurrentVCC2 Power Supply Low :Alarm indicating the XFP/OTX VCC2 power supply is lower than the threshold written in the EEPROM <Condtype> VCC2_LOW_ALARM_1 <Probcause>…
1.3.6.1.4.1.20044.29.2.3.2.212.1.5Columnpm1004mAlmVcc2HighAlarmPortnread-onlycurrentVCC2 Power Supply High :Alarm indicating the XFP/OTX VCC2 power supply is higher than the threshold written in the EEPROM <Condtype> VCC2_HIGH_ALARM_1 <Probcau…
1.3.6.1.4.1.20044.29.2.3.2.212.1.6Columnpm1004mAlmVcc3LowAlarmPortnread-onlycurrentVCC3 Power Supply Low :Alarm indicating the XFP/OTX VCC3 power supply is lower than the threshold written in the EEPROM <Condtype> VCC3_LOW_ALARM_1 <Probcause>…
1.3.6.1.4.1.20044.29.2.3.2.212.1.7Columnpm1004mAlmVcc3HighAlarmPortnread-onlycurrentVCC3 Power Supply High :Alarm indicating the XFP/OTX VCC3 power supply is higher than the threshold written in the EEPROM <Condtype> VCC3_HIGH_ALARM_1 <Probcau…
1.3.6.1.4.1.20044.29.2.3.2.212.1.8Columnpm1004mAlmVcc5LowAlarmPortnread-onlycurrentVCC5 Power Supply Low :Alarm indicating the XFP/OTX VCC5 power supply is lower than the threshold written in the EEPROM <Condtype> VCC5_LOW_ALARM_1 <Probcause>…
1.3.6.1.4.1.20044.29.2.3.2.212.1.9Columnpm1004mAlmVcc5HighAlarmPortnread-onlycurrentVCC5 Power Supply High :Alarm indicating the XFP/OTX VCC5 power supply is higher than the threshold written in the EEPROM <Condtype> VCC5_HIGH_ALARM_1 <Probcau…
1.3.6.1.4.1.20044.29.2.3.2.212.1.10Columnpm1004mAlmVee5LowWarningPortnread-onlycurrentVEE5 Power Supply Low Warning :Warning indicating the XFP/OTX VEE5 power supply is lower than the threshold written in the EEPROM <Condtype> VEE5_LOW_WARNING_1…
1.3.6.1.4.1.20044.29.2.3.2.212.1.11Columnpm1004mAlmVee5HighWarningPortnread-onlycurrentVEE5 Power Supply High Warning :Warning indicating the XFP/OTX VEE5 power supply is higher than the threshold written in the EEPROM <Condtype> VEE5_HIGH_WARNIN…
1.3.6.1.4.1.20044.29.2.3.2.212.1.12Columnpm1004mAlmVcc2LowWarningPortnread-onlycurrentVCC2 Power Supply Low Warning :Warning indicating the XFP/OTX VCC2 power supply is lower than the threshold written in the EEPROM <Condtype> VCC2_LOW_WARNING_1…
1.3.6.1.4.1.20044.29.2.3.2.212.1.13Columnpm1004mAlmVcc2HighWarningPortnread-onlycurrentVCC2 Power Supply High Warning :Warning indicating the XFP/OTX VCC2 power supply is higher than the threshold written in the EEPROM <Condtype> VCC2_HIGH_WARNIN…
1.3.6.1.4.1.20044.29.2.3.2.212.1.14Columnpm1004mAlmVcc3LowWarningPortnread-onlycurrentVCC3 Power Supply Low Warning :Warning indicating the XFP/OTX VCC3 power supply is lower than the threshold written in the EEPROM <Condtype> VCC3_LOW_WARNING_1…
1.3.6.1.4.1.20044.29.2.3.2.212.1.15Columnpm1004mAlmVcc3HighWarningPortnread-onlycurrentVCC3 Power Supply High Warning :Warning indicating the XFP/OTX VCC3 power supply is higher than the threshold written in the EEPROM <Condtype> VCC3_HIGH_WARNIN…
1.3.6.1.4.1.20044.29.2.3.2.212.1.16Columnpm1004mAlmVcc5LowWarningPortnread-onlycurrentVCC5 Power Supply Low Warning :Warning indicating the XFP/OTX VCC5 power supply is lower than the threshold written in the EEPROM <Condtype> VCC5_LOW_WARNING_1…
1.3.6.1.4.1.20044.29.2.3.2.212.1.17Columnpm1004mAlmVcc5HighWarningPortnread-onlycurrentVCC5 Power Supply High Warning :Warning indicating the XFP/OTX VCC5 power supply is higher than the threshold written in the EEPROM <Condtype> VCC5_HIGH_WARNIN…
1.3.6.1.4.1.20044.29.2.3.2.224Tablepm1004mAlmlineOtx1TlhAlarmsTablenot-accessiblecurrentList of pm1004mAlmlineOtx1TlhAlarms Article
1.3.6.1.4.1.20044.29.2.3.2.224.1Rowpm1004mAlmlineOtx1TlhAlarmsEntrynot-accessiblecurrentRow definition for the pm1004mAlmlineOtx1TlhAlarms table
1.3.6.1.4.1.20044.29.2.3.2.224.1.1Columnpm1004mAlmlineOtx1TlhAlarmsIndexread-onlycurrentIndex definition for the pm1004mAlmlineOtx1TlhAlarms table
1.3.6.1.4.1.20044.29.2.3.2.224.1.6Columnpm1004mAlmLineModulatorAgingHighAlaPortnread-onlycurrentLine Modulator Aging High Alarm :Alarm indicating the Line OTX TLH modulator aging is higher than the threshold written in the EEPROM <Condtype> LINE_MODULATOR…
1.3.6.1.4.1.20044.29.2.3.2.224.1.7Columnpm1004mAlmLineAgingHighAlaPortnread-onlycurrentLine OTX TLH Aging High Alarm :Alarm indicating the Line OTX TLH aging is higher than the threshold written in the EEPROM <Condtype> LINE_AGING_HIGH_ALA_1 <Pro…
1.3.6.1.4.1.20044.29.2.3.2.224.1.13Columnpm1004mAlmLineFreqDevHighAlaPortnread-onlycurrentLine Freq. Deviation High Alarm :Alarm indicating the Line OTX TLH frequency deviation is higher than the threshold written in the EEPROM <Condtype> LINE_FREQ_…
1.3.6.1.4.1.20044.29.2.3.2.224.1.15Columnpm1004mAlmLineLaserTempHighAlaPortnread-onlycurrentLine Laser Temp. High Alarm :Alarm indicating the Line OTX TLH laser temperature is higher than the threshold written in the EEPROM <Condtype> LINE_LASER_TEMP_…
1.3.6.1.4.1.20044.29.2.3.3Nodepm1004mAlmLineCrit
1.3.6.1.4.1.20044.29.2.3.3.7Tablepm1004mAlmsynthAlmLineTablenot-accessiblecurrentList of pm1004mAlmsynthAlmLine Article
1.3.6.1.4.1.20044.29.2.3.3.7.1Rowpm1004mAlmsynthAlmLineEntrynot-accessiblecurrentRow definition for the pm1004mAlmsynthAlmLine table
1.3.6.1.4.1.20044.29.2.3.3.7.1.1Columnpm1004mAlmsynthAlmLineIndexread-onlycurrentIndex definition for the pm1004mAlmsynthAlmLine table
1.3.6.1.4.1.20044.29.2.3.3.7.1.2Columnpm1004mAlmXfpAbsentPortnread-onlycurrentLine Optical Module Absent :This OID indicates that the line optical interface (XFP or OTX) is not plugged in. <Help> This alarm indicates if the line transcei…
1.3.6.1.4.1.20044.29.2.3.3.7.1.3Columnpm1004mAlmXfpInitNotComplPortnread-onlycurrentLine Optical Module Ready :This OID indicates that the optical interface (XFP or OTX) is not operational. <Help> This status indicates if the line transceiver …
1.3.6.1.4.1.20044.29.2.3.3.7.1.5Columnpm1004mAlmLineHwFailPortnread-onlycurrentLine Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Condtype> LINE_HW_FAIL <Probcause> equipmentMalfunction (1…
1.3.6.1.4.1.20044.29.2.3.3.7.1.6Columnpm1004mAlmXfpTxOffPortnread-onlycurrentLine Optical Module Laser Shutdown :This OID indicates the line optical output power is on <Help> This status indicates if the line transceiver laser is ON or …
1.3.6.1.4.1.20044.29.2.3.3.7.1.7Columnpm1004mAlmLineLocalOosPortnread-onlycurrentLine Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service…
1.3.6.1.4.1.20044.29.2.3.3.7.1.9Columnpm1004mAlmUpRdiInsPortnread-onlycurrentMS-RDI/L-RDI Inserted On Line :This OID indicates an upstream MS-RDI/L-RDI has been inserted in the outgoing OC192/STM64 signal. <Help> This status indicates i…
1.3.6.1.4.1.20044.29.2.3.3.7.1.10Columnpm1004mAlmLineDdmWarningPortnread-onlycurrentWarning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Warni…
1.3.6.1.4.1.20044.29.2.3.3.7.1.11Columnpm1004mAlmLineDdmAlmPortnread-onlycurrentAlarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Alarm ha…
1.3.6.1.4.1.20044.29.2.3.3.7.1.13Columnpm1004mAlmLineFailPortnread-onlycurrentLine Port Failure :This OID indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12) <Po…
1.3.6.1.4.1.20044.29.2.3.3.7.1.17Columnpm1004mAlmLineActivePortnread-onlycurrentLine Active :This bit indicates the line #n is active on receive side <Help> This status indicates whether the line is active or standby. <Condtype> LINE_ACTIV…
1.3.6.1.4.1.20044.29.2.3.3.128Tablepm1004mAlmdfrmAlmTablenot-accessiblecurrentList of pm1004mAlmdfrmAlm Article
1.3.6.1.4.1.20044.29.2.3.3.128.1Rowpm1004mAlmdfrmAlmEntrynot-accessiblecurrentRow definition for the pm1004mAlmdfrmAlm table
1.3.6.1.4.1.20044.29.2.3.3.128.1.1Columnpm1004mAlmdfrmAlmIndexread-onlycurrentIndex definition for the pm1004mAlmdfrmAlm table
1.3.6.1.4.1.20044.29.2.3.3.128.1.2Columnpm1004mAlmDwAisDetPortnread-onlycurrentMS-AIS/L-AIS Detected On Line Input :This OID indicates that an MS-AIS has been detected on the input signal <Help> This alarm indicates if there is a AIS is d…
1.3.6.1.4.1.20044.29.2.3.3.128.1.3Columnpm1004mAlmDwRdiDetPortnread-onlycurrentMS-RDI/L-RDI Detected On Line Input :This OID indicates that an MS-RDI has been detected on the input signal <Help> This alarm indicates if there is a RDI is d…
1.3.6.1.4.1.20044.29.2.3.3.128.1.4Columnpm1004mAlmDwOofPortnread-onlycurrentSONET/SDH Line Out Of Frame :This OID indicates that an Out Of Frame has been detected on the input signal <Help> This alarm indicates if there is a Out of Fra…
1.3.6.1.4.1.20044.29.2.3.3.128.1.5Columnpm1004mAlmDwLofPortnread-onlycurrentSONET/SDH Line Loss Of Frame :This OID indicates that a Loss Of Frame has been detected on the input signal <Help> This alarm indicates if there is a Loss of F…
1.3.6.1.4.1.20044.29.2.3.3.133Tablepm1004mAlmlineSyncAlarmsTablenot-accessiblecurrentList of pm1004mAlmlineSyncAlarms Article
1.3.6.1.4.1.20044.29.2.3.3.133.1Rowpm1004mAlmlineSyncAlarmsEntrynot-accessiblecurrentRow definition for the pm1004mAlmlineSyncAlarms table
1.3.6.1.4.1.20044.29.2.3.3.133.1.1Columnpm1004mAlmlineSyncAlarmsIndexread-onlycurrentIndex definition for the pm1004mAlmlineSyncAlarms table
1.3.6.1.4.1.20044.29.2.3.3.133.1.13Columnpm1004mAlmDwLockerrPortnread-onlycurrentDownstream Clock Lock Error :This OID indicates that the deserializer input 10 Gb/s clock recovery is not locked. <Condtype> DW_LOCKERR <Probcause> receiveFail…
1.3.6.1.4.1.20044.29.2.3.3.133.1.14Columnpm1004mAlmUpLockerrPortnread-onlycurrentUpstream Clock Lock Error :This OID indicates that the serializer output 10 Gb/s clock multiplier unit is not locked. <Condtype> UP_LOCKERR <Probcause> receive…
1.3.6.1.4.1.20044.29.2.3.3.133.1.17Columnpm1004mAlmDwLosPortnread-onlycurrentLine Input Loss Of Signal :This OID indicates a loss of signal on the 10 Gb/s input. <Help> This alarm indicates if an optical signal is detected on the line t…
1.3.6.1.4.1.20044.29.2.3.3.211Tablepm1004mAlmlineXfp1AlarmsTablenot-accessiblecurrentList of pm1004mAlmlineXfp1Alarms Article
1.3.6.1.4.1.20044.29.2.3.3.211.1Rowpm1004mAlmlineXfp1AlarmsEntrynot-accessiblecurrentRow definition for the pm1004mAlmlineXfp1Alarms table
1.3.6.1.4.1.20044.29.2.3.3.211.1.1Columnpm1004mAlmlineXfp1AlarmsIndexread-onlycurrentIndex definition for the pm1004mAlmlineXfp1Alarms table
1.3.6.1.4.1.20044.29.2.3.3.211.1.3Columnpm1004mAlmModNrPortnread-onlycurrentLine Optical Module Not Ready :This OID indicates that the module is unable to determine correct data. <Help> This alarm indicates if the line transceiver is r…
1.3.6.1.4.1.20044.29.2.3.3.211.1.4Columnpm1004mAlmRxCdrNotLockedPortnread-onlycurrentLine Optical Rx CDR Unlocked :This OID indicates that a loss of lock on the receiving side CDR has been detected <Help> This alarm indicates if the Rx CDR is l…
1.3.6.1.4.1.20044.29.2.3.3.211.1.6Columnpm1004mAlmRxNrPortnread-onlycurrentLine Optical Rx Not Ready :This OID indicates that a condition has arisen leading to invalid data on the receiving side. <Help> This alarm indicates if the Rx …
1.3.6.1.4.1.20044.29.2.3.3.211.1.7Columnpm1004mAlmTxCdrNotLockedPortnread-onlycurrentLine Optical Tx CDR Unlocked :This OID indicates a loss of lock on the transmitting side CDR has been detected. <Help> This alarm indicates if the Tx CDR is lo…
1.3.6.1.4.1.20044.29.2.3.3.211.1.8Columnpm1004mAlmTxFaultPortnread-onlycurrentLine Optical Tx Failure :This OID indicates a fault condition on the laser detected by the safety syste <Help> This alarm indicates if the laser of the line tr…
1.3.6.1.4.1.20044.29.2.3.3.211.1.9Columnpm1004mAlmTxNrPortnread-onlycurrentLine Optical Tx Not Ready :This OID indicates a condition has arisen leading to invalid data on the transmitting side <Help> This alarm indicates if the Tx par…
1.3.6.1.4.1.20044.29.2.3.3.211.1.15Columnpm1004mAlmWavelengthUnlockedPortnread-onlycurrentLine Optical Tx Wavelength Unlocked :This OID indicates that the wavelength error is exceeding the manufacturer tolerance <Help> This alarm indicates if the wa…
1.3.6.1.4.1.20044.29.2.3.3.211.1.16Columnpm1004mAlmTecFaultPortnread-onlycurrentLine Optical Tx Temp Regul Failed :This OID indicates a failure on the TEC module <Help> This alarm indicates if the TEC of the line transceiver is in fail con…
1.3.6.1.4.1.20044.29.2.3.3.211.1.17Columnpm1004mAlmApdSupplyFaultPortnread-onlycurrentLine Rx Photodiode Power Failed :This OID indicates a failure on the APD power supply <Help> This alarm indicates if the APD power supply is in fail condition …
1.3.6.1.4.1.20044.29.3Nodepm1004mmeasures
1.3.6.1.4.1.20044.29.3.1Nodepm1004mMesrOther
1.3.6.1.4.1.20044.29.3.1.0Scalarpm1004mMesrsynth0read-onlydeprecatedNot Used :This OID gives the unit used on AUX1 measurement of XFP#1 (Unit = )
1.3.6.1.4.1.20044.29.3.1.1Scalarpm1004mMesrsynth1read-onlydeprecatedNot Used :This OID gives the unit used on AUX2 measurement of XFP#1 (Unit = )
1.3.6.1.4.1.20044.29.3.2Nodepm1004mMesrClient
1.3.6.1.4.1.20044.29.3.2.16Tablepm1004mMesrtempMeasTablenot-accessiblecurrentList of pm1004mMesrtempMeas Article
1.3.6.1.4.1.20044.29.3.2.16.1Rowpm1004mMesrtempMeasEntrynot-accessiblecurrentRow definition for the pm1004mMesrtempMeas table
1.3.6.1.4.1.20044.29.3.2.16.1.1Columnpm1004mMesrtempMeasIndexread-onlycurrentIndex definition for the pm1004mMesrtempMeas table
1.3.6.1.4.1.20044.29.3.2.16.1.2Columnpm1004mMesrtempMeasPortnread-onlycurrentClient SFP Temperature :This OID gives the temperature value of the SFP plugged in port, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/25…
1.3.6.1.4.1.20044.29.3.2.24Tablepm1004mMesrvoltMeasTablenot-accessiblecurrentList of pm1004mMesrvoltMeas Article
1.3.6.1.4.1.20044.29.3.2.24.1Rowpm1004mMesrvoltMeasEntrynot-accessiblecurrentRow definition for the pm1004mMesrvoltMeas table
1.3.6.1.4.1.20044.29.3.2.24.1.1Columnpm1004mMesrvoltMeasIndexread-onlycurrentIndex definition for the pm1004mMesrvoltMeas table
1.3.6.1.4.1.20044.29.3.2.24.1.2Columnpm1004mMesrvoltMeasPortnread-onlycurrentClient SFP Power Supply :This OID gives the 3V3 voltage value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/100…
1.3.6.1.4.1.20044.29.3.2.32Tablepm1004mMesrbiasMeasTablenot-accessiblecurrentList of pm1004mMesrbiasMeas Article
1.3.6.1.4.1.20044.29.3.2.32.1Rowpm1004mMesrbiasMeasEntrynot-accessiblecurrentRow definition for the pm1004mMesrbiasMeas table
1.3.6.1.4.1.20044.29.3.2.32.1.1Columnpm1004mMesrbiasMeasIndexread-onlycurrentIndex definition for the pm1004mMesrbiasMeas table
1.3.6.1.4.1.20044.29.3.2.32.1.2Columnpm1004mMesrbiasMeasPortnread-onlycurrentClient SFP Laser Bias :This OID gives the bias value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA…
1.3.6.1.4.1.20044.29.3.2.40Tablepm1004mMesrtxpwrMeasTablenot-accessiblecurrentList of pm1004mMesrtxpwrMeas Article
1.3.6.1.4.1.20044.29.3.2.40.1Rowpm1004mMesrtxpwrMeasEntrynot-accessiblecurrentRow definition for the pm1004mMesrtxpwrMeas table
1.3.6.1.4.1.20044.29.3.2.40.1.1Columnpm1004mMesrtxpwrMeasIndexread-onlycurrentIndex definition for the pm1004mMesrtxpwrMeas table
1.3.6.1.4.1.20044.29.3.2.40.1.2Columnpm1004mMesrtxpwrMeasPortnread-onlycurrentClient SFP Tx Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV…
1.3.6.1.4.1.20044.29.3.2.48Tablepm1004mMesrrxpwrMeasTablenot-accessiblecurrentList of pm1004mMesrrxpwrMeas Article
1.3.6.1.4.1.20044.29.3.2.48.1Rowpm1004mMesrrxpwrMeasEntrynot-accessiblecurrentRow definition for the pm1004mMesrrxpwrMeas table
1.3.6.1.4.1.20044.29.3.2.48.1.1Columnpm1004mMesrrxpwrMeasIndexread-onlycurrentIndex definition for the pm1004mMesrrxpwrMeas table
1.3.6.1.4.1.20044.29.3.2.48.1.2Columnpm1004mMesrrxpwrMeasPortnread-onlycurrentClient SFP Rx Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-4…
1.3.6.1.4.1.20044.29.3.3Nodepm1004mMesrLine
1.3.6.1.4.1.20044.29.3.3.208Tablepm1004mMesrxfp1LxModTempMeasTablenot-accessiblecurrentList of pm1004mMesrxfp1LxModTempMeas Article
1.3.6.1.4.1.20044.29.3.3.208.1Rowpm1004mMesrxfp1LxModTempMeasEntrynot-accessiblecurrentRow definition for the pm1004mMesrxfp1LxModTempMeas table
1.3.6.1.4.1.20044.29.3.3.208.1.1Columnpm1004mMesrxfp1LxModTempMeasIndexread-onlycurrentIndex definition for the pm1004mMesrxfp1LxModTempMeas table
1.3.6.1.4.1.20044.29.3.3.208.1.2Columnpm1004mMesrxfp1LxModTempMeasPortnread-onlycurrentLine Optical Module Temperature :This OID gives the temperature of the XFP or OTX plugged in line, read from the DDM (Digital Diagnostic Monitoring) (Temperatu…
1.3.6.1.4.1.20044.29.3.3.209Tablepm1004mMesrxfp1ReservedTablenot-accessibledeprecatedList of pm1004mMesrxfp1Reserved Article
1.3.6.1.4.1.20044.29.3.3.209.1Rowpm1004mMesrxfp1ReservedEntrynot-accessibledeprecatedRow definition for the pm1004mMesrxfp1Reserved table
1.3.6.1.4.1.20044.29.3.3.209.1.1Columnpm1004mMesrxfp1ReservedIndexread-onlydeprecatedIndex definition for the pm1004mMesrxfp1Reserved table
1.3.6.1.4.1.20044.29.3.3.209.1.2Columnpm1004mMesrxfp1ReservedPortnread-onlydeprecatedNot Used :Reserved
1.3.6.1.4.1.20044.29.3.3.210Tablepm1004mMesrxfp1LoBiasCurrentMeasTablenot-accessiblecurrentList of pm1004mMesrxfp1LoBiasCurrentMeas Article
1.3.6.1.4.1.20044.29.3.3.210.1Rowpm1004mMesrxfp1LoBiasCurrentMeasEntrynot-accessiblecurrentRow definition for the pm1004mMesrxfp1LoBiasCurrentMeas table
1.3.6.1.4.1.20044.29.3.3.210.1.1Columnpm1004mMesrxfp1LoBiasCurrentMeasIndexread-onlycurrentIndex definition for the pm1004mMesrxfp1LoBiasCurrentMeas table
1.3.6.1.4.1.20044.29.3.3.210.1.2Columnpm1004mMesrxfp1LoBiasCurrentMeasPortnread-onlycurrentLine Optical Module Laser Bias :This OID gives the bias value of the XFP or OTX plugged in line , read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/…
1.3.6.1.4.1.20044.29.3.3.211Tablepm1004mMesrxfp1LoTxPowerMeasTablenot-accessiblecurrentList of pm1004mMesrxfp1LoTxPowerMeas Article
1.3.6.1.4.1.20044.29.3.3.211.1Rowpm1004mMesrxfp1LoTxPowerMeasEntrynot-accessiblecurrentRow definition for the pm1004mMesrxfp1LoTxPowerMeas table
1.3.6.1.4.1.20044.29.3.3.211.1.1Columnpm1004mMesrxfp1LoTxPowerMeasIndexread-onlycurrentIndex definition for the pm1004mMesrxfp1LoTxPowerMeas table
1.3.6.1.4.1.20044.29.3.3.211.1.2Columnpm1004mMesrxfp1LoTxPowerMeasPortnread-onlycurrentLine Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line , read from the DDM (Digital Diagnostic Monitoring) (Po…
1.3.6.1.4.1.20044.29.3.3.212Tablepm1004mMesrxfp1LiRxPowerMeasTablenot-accessiblecurrentList of pm1004mMesrxfp1LiRxPowerMeas Article
1.3.6.1.4.1.20044.29.3.3.212.1Rowpm1004mMesrxfp1LiRxPowerMeasEntrynot-accessiblecurrentRow definition for the pm1004mMesrxfp1LiRxPowerMeas table
1.3.6.1.4.1.20044.29.3.3.212.1.1Columnpm1004mMesrxfp1LiRxPowerMeasIndexread-onlycurrentIndex definition for the pm1004mMesrxfp1LiRxPowerMeas table
1.3.6.1.4.1.20044.29.3.3.212.1.2Columnpm1004mMesrxfp1LiRxPowerMeasPortnread-onlycurrentLine Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line , read from the DDM (Digital Diagnostic Monitoring) (Pow…
1.3.6.1.4.1.20044.29.3.3.213Tablepm1004mMesrxfp1LxAux1MeasTablenot-accessibledeprecatedList of pm1004mMesrxfp1LxAux1Meas Article
1.3.6.1.4.1.20044.29.3.3.213.1Rowpm1004mMesrxfp1LxAux1MeasEntrynot-accessibledeprecatedRow definition for the pm1004mMesrxfp1LxAux1Meas table
1.3.6.1.4.1.20044.29.3.3.213.1.1Columnpm1004mMesrxfp1LxAux1MeasIndexread-onlydeprecatedIndex definition for the pm1004mMesrxfp1LxAux1Meas table
1.3.6.1.4.1.20044.29.3.3.213.1.2Columnpm1004mMesrxfp1LxAux1MeasPortnread-onlydeprecatedNot Used :This OID gives the receive power value read in the DDM (Digital Diagnostic Monitoring) of the XFP or OTX plugged in line (Unit = ?)
1.3.6.1.4.1.20044.29.3.3.214Tablepm1004mMesrxfp1LxAux2MeasTablenot-accessibledeprecatedList of pm1004mMesrxfp1LxAux2Meas Article
1.3.6.1.4.1.20044.29.3.3.214.1Rowpm1004mMesrxfp1LxAux2MeasEntrynot-accessibledeprecatedRow definition for the pm1004mMesrxfp1LxAux2Meas table
1.3.6.1.4.1.20044.29.3.3.214.1.1Columnpm1004mMesrxfp1LxAux2MeasIndexread-onlydeprecatedIndex definition for the pm1004mMesrxfp1LxAux2Meas table
1.3.6.1.4.1.20044.29.3.3.214.1.2Columnpm1004mMesrxfp1LxAux2MeasPortnread-onlydeprecatedNot Used :This OID gives the receive power value read in the DDM (Digital Diagnostic Monitoring) of the XFP or OTX plugged in line (Unit = ?)
1.3.6.1.4.1.20044.29.3.3.224Tablepm1004mMesrotx1AgingTablenot-accessiblecurrentList of pm1004mMesrotx1Aging Article
1.3.6.1.4.1.20044.29.3.3.224.1Rowpm1004mMesrotx1AgingEntrynot-accessiblecurrentRow definition for the pm1004mMesrotx1Aging table
1.3.6.1.4.1.20044.29.3.3.224.1.1Columnpm1004mMesrotx1AgingIndexread-onlycurrentIndex definition for the pm1004mMesrotx1Aging table
1.3.6.1.4.1.20044.29.3.3.224.1.2Columnpm1004mMesrotx1AgingPortnread-onlycurrentLine OTX TLH Aging :This OID gives the aging of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Aging = AV) (Unit = %) <Help> This measure…
1.3.6.1.4.1.20044.29.3.3.225Tablepm1004mMesrotx1LaserTemperatureTablenot-accessibledeprecatedList of pm1004mMesrotx1LaserTemperature Article
1.3.6.1.4.1.20044.29.3.3.225.1Rowpm1004mMesrotx1LaserTemperatureEntrynot-accessibledeprecatedRow definition for the pm1004mMesrotx1LaserTemperature table
1.3.6.1.4.1.20044.29.3.3.225.1.1Columnpm1004mMesrotx1LaserTemperatureIndexread-onlydeprecatedIndex definition for the pm1004mMesrotx1LaserTemperature table
1.3.6.1.4.1.20044.29.3.3.225.1.2Columnpm1004mMesrotx1LaserTemperaturePortnread-onlydeprecatedLine OTX TLH Laser Temperature :This OID gives the laser temperature of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/2…
1.3.6.1.4.1.20044.29.3.3.226Tablepm1004mMesrotx1FreqDeviationTablenot-accessiblecurrentList of pm1004mMesrotx1FreqDeviation Article
1.3.6.1.4.1.20044.29.3.3.226.1Rowpm1004mMesrotx1FreqDeviationEntrynot-accessiblecurrentRow definition for the pm1004mMesrotx1FreqDeviation table
1.3.6.1.4.1.20044.29.3.3.226.1.1Columnpm1004mMesrotx1FreqDeviationIndexread-onlycurrentIndex definition for the pm1004mMesrotx1FreqDeviation table
1.3.6.1.4.1.20044.29.3.3.226.1.2Columnpm1004mMesrotx1FreqDeviationPortnread-onlycurrentLine OTX TLH Frequency Deviation :This OID gives the frequency deviation of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Deviation = (A…
1.3.6.1.4.1.20044.29.3.3.227Tablepm1004mMesrotx1LaserWvlengthTablenot-accessiblecurrentList of pm1004mMesrotx1LaserWvlength Article
1.3.6.1.4.1.20044.29.3.3.227.1Rowpm1004mMesrotx1LaserWvlengthEntrynot-accessiblecurrentRow definition for the pm1004mMesrotx1LaserWvlength table
1.3.6.1.4.1.20044.29.3.3.227.1.1Columnpm1004mMesrotx1LaserWvlengthIndexread-onlycurrentIndex definition for the pm1004mMesrotx1LaserWvlength table
1.3.6.1.4.1.20044.29.3.3.227.1.2Columnpm1004mMesrotx1LaserWvlengthPortnread-onlycurrentLine Optical Module Wavelength :This OID gives the laser wavelength of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Wavelength=29979245…
1.3.6.1.4.1.20044.29.4Nodepm1004mcounters
1.3.6.1.4.1.20044.29.4.1Nodepm1004mCntOther
1.3.6.1.4.1.20044.29.4.2Nodepm1004mCntClient
1.3.6.1.4.1.20044.29.4.2.16Tablepm1004mCntupRaRemCntTablenot-accessiblecurrentList of pm1004mCntupRaRemCnt Article
1.3.6.1.4.1.20044.29.4.2.16.1Rowpm1004mCntupRaRemCntEntrynot-accessiblecurrentRow definition for the pm1004mCntupRaRemCnt table
1.3.6.1.4.1.20044.29.4.2.16.1.1Columnpm1004mCntupRaRemCntIndexread-onlycurrentIndex definition for the pm1004mCntupRaRemCnt table
1.3.6.1.4.1.20044.29.4.2.16.1.2Columnpm1004mCntupRaRemCntValuePortnread-onlycurrentClient Rate Adapt. Words Removal :This counter is incremented each time a rate adaptation 10B word is removed from the Client input stream
1.3.6.1.4.1.20044.29.4.2.16.1.3Columnpm1004mCntupRaRemCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the rate adaptation removal counter value is invalid on Port
1.3.6.1.4.1.20044.29.4.2.16.1.4Columnpm1004mCntupRaRemCntOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a rate adaptation removal counter overload on Port
1.3.6.1.4.1.20044.29.4.2.24Tablepm1004mCntupRaInsCntTablenot-accessiblecurrentList of pm1004mCntupRaInsCnt Article
1.3.6.1.4.1.20044.29.4.2.24.1Rowpm1004mCntupRaInsCntEntrynot-accessiblecurrentRow definition for the pm1004mCntupRaInsCnt table
1.3.6.1.4.1.20044.29.4.2.24.1.1Columnpm1004mCntupRaInsCntIndexread-onlycurrentIndex definition for the pm1004mCntupRaInsCnt table
1.3.6.1.4.1.20044.29.4.2.24.1.2Columnpm1004mCntupRaInsCntValuePortnread-onlycurrentClient Rate Adapt. Words Insertion :This counter is incremented each time a rate adaptation 10B word is inserted in the Client input stream
1.3.6.1.4.1.20044.29.4.2.24.1.3Columnpm1004mCntupRaInsCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the rate adaptation insertion counter value is invalid on Port
1.3.6.1.4.1.20044.29.4.2.24.1.4Columnpm1004mCntupRaInsCntOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a rate adaptation insertion counter overload on Port
1.3.6.1.4.1.20044.29.4.2.32Tablepm1004mCntupRdErrCntTablenot-accessiblecurrentList of pm1004mCntupRdErrCnt Article
1.3.6.1.4.1.20044.29.4.2.32.1Rowpm1004mCntupRdErrCntEntrynot-accessiblecurrentRow definition for the pm1004mCntupRdErrCnt table
1.3.6.1.4.1.20044.29.4.2.32.1.1Columnpm1004mCntupRdErrCntIndexread-onlycurrentIndex definition for the pm1004mCntupRdErrCnt table
1.3.6.1.4.1.20044.29.4.2.32.1.2Columnpm1004mCntupRdErrCntValuePortnread-onlycurrentClient Input Errors :This counter is increased each time a 10b/8b running disparity error is detected on the Client input stream <Help> This counter gives the …
1.3.6.1.4.1.20044.29.4.2.32.1.3Columnpm1004mCntupRdErrCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the client error counter value is invalid on Port
1.3.6.1.4.1.20044.29.4.2.32.1.4Columnpm1004mCntupRdErrCntOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a client input error counter overload on Port
1.3.6.1.4.1.20044.29.4.2.40Tablepm1004mCntupTimCntTablenot-accessiblecurrentList of pm1004mCntupTimCnt Article
1.3.6.1.4.1.20044.29.4.2.40.1Rowpm1004mCntupTimCntEntrynot-accessiblecurrentRow definition for the pm1004mCntupTimCnt table
1.3.6.1.4.1.20044.29.4.2.40.1.1Columnpm1004mCntupTimCntIndexread-onlycurrentIndex definition for the pm1004mCntupTimCnt table
1.3.6.1.4.1.20044.29.4.2.40.1.2Columnpm1004mCntupTimCntValuePortnread-onlycurrentClient Upstream Timer Counter :This is the timing counter dedicated to the upstream access counters. It is incremented every 125 us.
1.3.6.1.4.1.20044.29.4.2.40.1.3Columnpm1004mCntupTimCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the upstream timing counter value is invalid on Port
1.3.6.1.4.1.20044.29.4.2.40.1.4Columnpm1004mCntupTimCntOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a upstream timing counter overload on Port
1.3.6.1.4.1.20044.29.4.2.48Tablepm1004mCntupCvErrCntTablenot-accessiblecurrentList of pm1004mCntupCvErrCnt Article
1.3.6.1.4.1.20044.29.4.2.48.1Rowpm1004mCntupCvErrCntEntrynot-accessiblecurrentRow definition for the pm1004mCntupCvErrCnt table
1.3.6.1.4.1.20044.29.4.2.48.1.1Columnpm1004mCntupCvErrCntIndexread-onlycurrentIndex definition for the pm1004mCntupCvErrCnt table
1.3.6.1.4.1.20044.29.4.2.48.1.2Columnpm1004mCntupCvErrCntValuePortnread-onlycurrentClient Coding Violation Counter :This counter is increased each time a 10b/8b coding violation is detected on the Client input stream
1.3.6.1.4.1.20044.29.4.2.48.1.3Columnpm1004mCntupCvErrCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the coding violation counter value is invalid on Port
1.3.6.1.4.1.20044.29.4.2.48.1.4Columnpm1004mCntupCvErrCntOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a coding violation counter overload on Port
1.3.6.1.4.1.20044.29.4.2.72Tablepm1004mCntdwTimCntTablenot-accessiblecurrentList of pm1004mCntdwTimCnt Article
1.3.6.1.4.1.20044.29.4.2.72.1Rowpm1004mCntdwTimCntEntrynot-accessiblecurrentRow definition for the pm1004mCntdwTimCnt table
1.3.6.1.4.1.20044.29.4.2.72.1.1Columnpm1004mCntdwTimCntIndexread-onlycurrentIndex definition for the pm1004mCntdwTimCnt table
1.3.6.1.4.1.20044.29.4.2.72.1.2Columnpm1004mCntdwTimCntValuePortnread-onlycurrentClient Downstream Timer Counter :This is the timing counter dedicated to the downstream access counters. It is incremented every 125 us.
1.3.6.1.4.1.20044.29.4.2.72.1.3Columnpm1004mCntdwTimCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the downstream timer counter value is invalid on Port
1.3.6.1.4.1.20044.29.4.2.72.1.4Columnpm1004mCntdwTimCntOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a downstream timer counter overload on Port
1.3.6.1.4.1.20044.29.4.3Nodepm1004mCntLine
1.3.6.1.4.1.20044.29.4.3.152Tablepm1004mCntdfrmB1ErrCntTablenot-accessiblecurrentList of pm1004mCntdfrmB1ErrCnt Article
1.3.6.1.4.1.20044.29.4.3.152.1Rowpm1004mCntdfrmB1ErrCntEntrynot-accessiblecurrentRow definition for the pm1004mCntdfrmB1ErrCnt table
1.3.6.1.4.1.20044.29.4.3.152.1.1Columnpm1004mCntdfrmB1ErrCntIndexread-onlycurrentIndex definition for the pm1004mCntdfrmB1ErrCnt table
1.3.6.1.4.1.20044.29.4.3.152.1.2Columnpm1004mCntdfrmB1ErrCntValuePortnread-onlycurrentLine Input B1 Errors :This counter is incremented each time a SM BIP error is detected on the Deframer input stream. <Help> This counter gives the number of BI…
1.3.6.1.4.1.20044.29.4.3.152.1.3Columnpm1004mCntdfrmB1ErrCntErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the SM BIP error counter value is invalid on Port
1.3.6.1.4.1.20044.29.4.3.152.1.4Columnpm1004mCntdfrmB1ErrCntOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a SM BIP error counter overload on Port
1.3.6.1.4.1.20044.29.4.3.153Tablepm1004mCntdfrmTimCntTablenot-accessiblecurrentList of pm1004mCntdfrmTimCnt Article
1.3.6.1.4.1.20044.29.4.3.153.1Rowpm1004mCntdfrmTimCntEntrynot-accessiblecurrentRow definition for the pm1004mCntdfrmTimCnt table
1.3.6.1.4.1.20044.29.4.3.153.1.1Columnpm1004mCntdfrmTimCntIndexread-onlycurrentIndex definition for the pm1004mCntdfrmTimCnt table
1.3.6.1.4.1.20044.29.4.3.153.1.2Columnpm1004mCntdfrmTimCntValuePortnread-onlycurrentLine Timer Counter :This is the timing counter dedicated to the downstream deframer counters. It is incremented every 125 us.
1.3.6.1.4.1.20044.29.4.3.153.1.3Columnpm1004mCntdfrmTimCntErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.29.4.3.153.1.4Columnpm1004mCntdfrmTimCntOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.29.4.259Scalarpm1004mCntCountersResetread-writecurrentCounters Reset:This OID resets and restarts all the counters
1.3.6.1.4.1.20044.29.4.260Scalarpm1004mCntCountersStopread-writecurrentCounters stop:This OID stops all the counters
1.3.6.1.4.1.20044.29.6Nodepm1004mcontrolsWrite
1.3.6.1.4.1.20044.29.6.1Nodepm1004mCtrlOther
1.3.6.1.4.1.20044.29.6.1.1Nodepm1004mCtrlconfMgnt1
1.3.6.1.4.1.20044.29.6.1.1.1Scalarpm1004mCtrlConf1Load1read-writecurrentLoad Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM.
1.3.6.1.4.1.20044.29.6.1.1.2Scalarpm1004mCtrlConf2Load1read-writecurrentLoad Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM.
1.3.6.1.4.1.20044.29.6.1.1.10Scalarpm1004mCtrlConf2Flash1read-writecurrentWrite Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura…
1.3.6.1.4.1.20044.29.6.1.1.14Scalarpm1004mCtrlConf2Clear1read-writecurrentClear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o…
1.3.6.1.4.1.20044.29.6.1.4Nodepm1004mCtrlsynth4
1.3.6.1.4.1.20044.29.6.1.4.1Scalarpm1004mCtrlCorrelatOnread-writecurrentEnable Alarm Correlation :This OID enables the alarm correlation in the PM.
1.3.6.1.4.1.20044.29.6.1.4.2Scalarpm1004mCtrlCorrelatOffread-writecurrentDisable Alarm Correlation :This OID disables the alarm correlation in the PM.
1.3.6.1.4.1.20044.29.6.1.5Nodepm1004mCtrlswMgnt
1.3.6.1.4.1.20044.29.6.1.5.2Scalarpm1004mCtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> …
1.3.6.1.4.1.20044.29.6.1.5.3Scalarpm1004mCtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th…
1.3.6.1.4.1.20044.29.6.1.5.5Scalarpm1004mCtrlLoadSwBank1read-writecurrentSet Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW…
1.3.6.1.4.1.20044.29.6.1.5.6Scalarpm1004mCtrlLoadSwBank2read-writecurrentSet Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S…
1.3.6.1.4.1.20044.29.6.1.6Nodepm1004mCtrlgwMgnt
1.3.6.1.4.1.20044.29.6.1.6.1Scalarpm1004mCtrlCurrentGwResetread-writecurrentActive Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting.
1.3.6.1.4.1.20044.29.6.1.6.5Scalarpm1004mCtrlLoadGwBank1read-writecurrentSet Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.29.6.1.6.6Scalarpm1004mCtrlLoadGwBank2read-writecurrentSet Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.29.6.1.6.7Scalarpm1004mCtrlLoadGwBank3read-writecurrentSet Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.29.6.1.6.8Scalarpm1004mCtrlLoadGwBank4read-writecurrentSet Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.29.6.1.192Nodepm1004mCtrlledTest
1.3.6.1.4.1.20044.29.6.1.192.1Scalarpm1004mCtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.29.6.1.192.2Scalarpm1004mCtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.29.6.1.192.3Scalarpm1004mCtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.29.6.1.193Nodepm1004mCtrlmoduleOosMode
1.3.6.1.4.1.20044.29.6.1.193.1Scalarpm1004mCtrlModuleOosModeread-writecurrentPM Out Of Service :This OID sets the PM Out Of Service <Help> This control defines the service state of the complete module
1.3.6.1.4.1.20044.29.6.1.197Nodepm1004mCtrlmaintenanceMode
1.3.6.1.4.1.20044.29.6.1.197.1Scalarpm1004mCtrlMaintenanceModeread-writecurrentModule Maintenance Mode :This OID enables the maintenance mode on the PM. <Help> This control enables the maintenance mode on the PM.
1.3.6.1.4.1.20044.29.6.1.198Nodepm1004mCtrldccEnable
1.3.6.1.4.1.20044.29.6.1.198.1Scalarpm1004mCtrlDccEnableread-writecurrentDCC Enable :This OID enables the DCC mode on the PM <Help> This control enables the DCC mode on the PM
1.3.6.1.4.1.20044.29.6.2Nodepm1004mCtrlClient
1.3.6.1.4.1.20044.29.6.2.16Tablepm1004mCtrlaccessLoopTablenot-accessiblecurrentList of pm1004mCtrlaccessLoop Article
1.3.6.1.4.1.20044.29.6.2.16.1Rowpm1004mCtrlaccessLoopEntrynot-accessiblecurrentRow definition for the pm1004mCtrlaccessLoop table
1.3.6.1.4.1.20044.29.6.2.16.1.1Columnpm1004mCtrlaccessLoopIndexread-onlycurrentIndex definition for the pm1004mCtrlaccessLoop table
1.3.6.1.4.1.20044.29.6.2.16.1.2Columnpm1004mCtrlaccessLoopPortnread-writecurrentClient Facility Loopback :This OID operates a Client Facility Loopback, looping client input signal on the client output port. The loop is located on the clien…
1.3.6.1.4.1.20044.29.6.2.18Tablepm1004mCtrlportOosModeTablenot-accessiblecurrentList of pm1004mCtrlportOosMode Article
1.3.6.1.4.1.20044.29.6.2.18.1Rowpm1004mCtrlportOosModeEntrynot-accessiblecurrentRow definition for the pm1004mCtrlportOosMode table
1.3.6.1.4.1.20044.29.6.2.18.1.1Columnpm1004mCtrlportOosModeIndexread-onlycurrentIndex definition for the pm1004mCtrlportOosMode table
1.3.6.1.4.1.20044.29.6.2.18.1.2Columnpm1004mCtrlportOosModePortnread-writecurrentClient Port Out Of Service :This OID sets the client port Out Of Service <Help> This controls defines the service state of the client port
1.3.6.1.4.1.20044.29.6.2.19Tablepm1004mCtrlsfpOnCtrlTablenot-accessiblecurrentList of pm1004mCtrlsfpOnCtrl Article
1.3.6.1.4.1.20044.29.6.2.19.1Rowpm1004mCtrlsfpOnCtrlEntrynot-accessiblecurrentRow definition for the pm1004mCtrlsfpOnCtrl table
1.3.6.1.4.1.20044.29.6.2.19.1.1Columnpm1004mCtrlsfpOnCtrlIndexread-onlycurrentIndex definition for the pm1004mCtrlsfpOnCtrl table
1.3.6.1.4.1.20044.29.6.2.19.1.2Columnpm1004mCtrlsfpOnCtrlPortnread-writecurrentClient SFP Optical Laser ON :This OID switches on the SFP.
1.3.6.1.4.1.20044.29.6.2.20Tablepm1004mCtrlsfpOffCtrlTablenot-accessiblecurrentList of pm1004mCtrlsfpOffCtrl Article
1.3.6.1.4.1.20044.29.6.2.20.1Rowpm1004mCtrlsfpOffCtrlEntrynot-accessiblecurrentRow definition for the pm1004mCtrlsfpOffCtrl table
1.3.6.1.4.1.20044.29.6.2.20.1.1Columnpm1004mCtrlsfpOffCtrlIndexread-onlycurrentIndex definition for the pm1004mCtrlsfpOffCtrl table
1.3.6.1.4.1.20044.29.6.2.20.1.2Columnpm1004mCtrlsfpOffCtrlPortnread-writecurrentClient SFP Laser Shutdown :This OID switches off the SFP. <Help> This control defines the laser state of the client transceiver
1.3.6.1.4.1.20044.29.6.2.21Tablepm1004mCtrlcsfUpInsTablenot-accessiblecurrentList of pm1004mCtrlcsfUpIns Article
1.3.6.1.4.1.20044.29.6.2.21.1Rowpm1004mCtrlcsfUpInsEntrynot-accessiblecurrentRow definition for the pm1004mCtrlcsfUpIns table
1.3.6.1.4.1.20044.29.6.2.21.1.1Columnpm1004mCtrlcsfUpInsIndexread-onlycurrentIndex definition for the pm1004mCtrlcsfUpIns table
1.3.6.1.4.1.20044.29.6.2.21.1.2Columnpm1004mCtrlcsfUpInsPortnread-writecurrentClient Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo…
1.3.6.1.4.1.20044.29.6.2.22Tablepm1004mCtrlcaisDwInsTablenot-accessiblecurrentList of pm1004mCtrlcaisDwIns Article
1.3.6.1.4.1.20044.29.6.2.22.1Rowpm1004mCtrlcaisDwInsEntrynot-accessiblecurrentRow definition for the pm1004mCtrlcaisDwIns table
1.3.6.1.4.1.20044.29.6.2.22.1.1Columnpm1004mCtrlcaisDwInsIndexread-onlycurrentIndex definition for the pm1004mCtrlcaisDwIns table
1.3.6.1.4.1.20044.29.6.2.22.1.2Columnpm1004mCtrlcaisDwInsPortnread-writecurrentClient AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port
1.3.6.1.4.1.20044.29.6.2.26Tablepm1004mCtrlclientAccessTermLoopTablenot-accessiblecurrentList of pm1004mCtrlclientAccessTermLoop Article
1.3.6.1.4.1.20044.29.6.2.26.1Rowpm1004mCtrlclientAccessTermLoopEntrynot-accessiblecurrentRow definition for the pm1004mCtrlclientAccessTermLoop table
1.3.6.1.4.1.20044.29.6.2.26.1.1Columnpm1004mCtrlclientAccessTermLoopIndexread-onlycurrentIndex definition for the pm1004mCtrlclientAccessTermLoop table
1.3.6.1.4.1.20044.29.6.2.26.1.2Columnpm1004mCtrlclientAccessTermLoopPortnread-writecurrentClient Terminal Loopback :This OID operates a Client Terminal Loopback, looping client input signal on the client output port. The loop is located on the line …
1.3.6.1.4.1.20044.29.6.2.35Tablepm1004mCtrlresetCount15PortTablenot-accessiblecurrentList of pm1004mCtrlresetCount15Port Article
1.3.6.1.4.1.20044.29.6.2.35.1Rowpm1004mCtrlresetCount15PortEntrynot-accessiblecurrentRow definition for the pm1004mCtrlresetCount15Port table
1.3.6.1.4.1.20044.29.6.2.35.1.1Columnpm1004mCtrlresetCount15PortIndexread-onlycurrentIndex definition for the pm1004mCtrlresetCount15Port table
1.3.6.1.4.1.20044.29.6.2.35.1.2Columnpm1004mCtrlclientResetAllPerfCount15Portnread-writecurrentClient 15-min Counters Reset :This OID resets all the current 15-min Counters on the client port
1.3.6.1.4.1.20044.29.6.2.36Tablepm1004mCtrlresetCount24PortTablenot-accessiblecurrentList of pm1004mCtrlresetCount24Port Article
1.3.6.1.4.1.20044.29.6.2.36.1Rowpm1004mCtrlresetCount24PortEntrynot-accessiblecurrentRow definition for the pm1004mCtrlresetCount24Port table
1.3.6.1.4.1.20044.29.6.2.36.1.1Columnpm1004mCtrlresetCount24PortIndexread-onlycurrentIndex definition for the pm1004mCtrlresetCount24Port table
1.3.6.1.4.1.20044.29.6.2.36.1.2Columnpm1004mCtrlclientResetAllPerfCount24Portnread-writecurrentClient 24-hours Counters Reset :This OID resets all the current 24-hours Counters on the client port
1.3.6.1.4.1.20044.29.6.3Nodepm1004mCtrlLine
1.3.6.1.4.1.20044.29.6.3.64Nodepm1004mCtrlcommAccessLoop
1.3.6.1.4.1.20044.29.6.3.64.1Scalarpm1004mCtrlCommAccessloopread-writedeprecatedPM Full Access Loop Mode :This OID, when set, puts the module in common access loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.
1.3.6.1.4.1.20044.29.6.3.66Nodepm1004mCtrllineLoop
1.3.6.1.4.1.20044.29.6.3.66.1Scalarpm1004mCtrlLineLoopread-writedeprecatedPM Line Loop Mode :This OID, when set at '1' puts the module in line loopback mode, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. The Ups…
1.3.6.1.4.1.20044.29.6.3.67Nodepm1004mCtrlmsAis
1.3.6.1.4.1.20044.29.6.3.67.1Scalarpm1004mCtrlMsAisread-writecurrentInsert MS-AIS/L-AIS On Line Output :This OID, when set, inserts an MS-AIS/L-AIS in the outgoing STM-64/OC-192 signal.
1.3.6.1.4.1.20044.29.6.3.73Nodepm1004mCtrlProtMgnt
1.3.6.1.4.1.20044.29.6.3.73.1Scalarpm1004mCtrlLineNumberread-writecurrentActive Line Number : This OID sets the active line number
1.3.6.1.4.1.20044.29.6.3.73.2Scalarpm1004mCtrlProtModeread-writecurrentLine Switch Mode (Auto Or Manual) :This bit selects the manual (1) or automatic (0) switch method <Help> This control defines the protection switch mode on the…
1.3.6.1.4.1.20044.29.6.3.74Tablepm1004mCtrllineOosModeTablenot-accessiblecurrentList of pm1004mCtrllineOosMode Article
1.3.6.1.4.1.20044.29.6.3.74.1Rowpm1004mCtrllineOosModeEntrynot-accessiblecurrentRow definition for the pm1004mCtrllineOosMode table
1.3.6.1.4.1.20044.29.6.3.74.1.1Columnpm1004mCtrllineOosModeIndexread-onlycurrentIndex definition for the pm1004mCtrllineOosMode table
1.3.6.1.4.1.20044.29.6.3.74.1.2Columnpm1004mCtrllineOosModePortnread-writecurrentLine Port Out Of Service :This OID sets the line port Out Of Service <Help> This control defines the service state of the line port
1.3.6.1.4.1.20044.29.6.3.86Tablepm1004mCtrllineResetCount15LineTablenot-accessiblecurrentList of pm1004mCtrllineResetCount15Line Article
1.3.6.1.4.1.20044.29.6.3.86.1Rowpm1004mCtrllineResetCount15LineEntrynot-accessiblecurrentRow definition for the pm1004mCtrllineResetCount15Line table
1.3.6.1.4.1.20044.29.6.3.86.1.1Columnpm1004mCtrllineResetCount15LineIndexread-onlycurrentIndex definition for the pm1004mCtrllineResetCount15Line table
1.3.6.1.4.1.20044.29.6.3.86.1.2Columnpm1004mCtrlresetAllPerfCount15Portnread-writecurrentLine 15-min Counters Reset :This OID resets all the current 15-min Counters on the client port
1.3.6.1.4.1.20044.29.6.3.87Tablepm1004mCtrllineResetCount24LineTablenot-accessiblecurrentList of pm1004mCtrllineResetCount24Line Article
1.3.6.1.4.1.20044.29.6.3.87.1Rowpm1004mCtrllineResetCount24LineEntrynot-accessiblecurrentRow definition for the pm1004mCtrllineResetCount24Line table
1.3.6.1.4.1.20044.29.6.3.87.1.1Columnpm1004mCtrllineResetCount24LineIndexread-onlycurrentIndex definition for the pm1004mCtrllineResetCount24Line table
1.3.6.1.4.1.20044.29.6.3.87.1.2Columnpm1004mCtrlresetAllPerfCount24Portnread-writecurrentLine 24-hours Counters Reset :This OID resets all the current 24-hours Counters on the client port
1.3.6.1.4.1.20044.29.6.3.208Tablepm1004mCtrlxfpOnoffTablenot-accessiblecurrentList of pm1004mCtrlxfpOnoff Article
1.3.6.1.4.1.20044.29.6.3.208.1Rowpm1004mCtrlxfpOnoffEntrynot-accessiblecurrentRow definition for the pm1004mCtrlxfpOnoff table
1.3.6.1.4.1.20044.29.6.3.208.1.1Columnpm1004mCtrlxfpOnoffIndexread-onlycurrentIndex definition for the pm1004mCtrlxfpOnoff table
1.3.6.1.4.1.20044.29.6.3.208.1.2Columnpm1004mCtrlxfpOnoffPortnread-writecurrentLine Optical Laser Shutdown :This OID switches off the XFP or the OTX <Help> This control defines the laser state of the line transceiver
1.3.6.1.4.1.20044.29.6.3.209Tablepm1004mCtrlxfpLineLoopTablenot-accessiblecurrentList of pm1004mCtrlxfpLineLoop Article
1.3.6.1.4.1.20044.29.6.3.209.1Rowpm1004mCtrlxfpLineLoopEntrynot-accessiblecurrentRow definition for the pm1004mCtrlxfpLineLoop table
1.3.6.1.4.1.20044.29.6.3.209.1.1Columnpm1004mCtrlxfpLineLoopIndexread-onlycurrentIndex definition for the pm1004mCtrlxfpLineLoop table
1.3.6.1.4.1.20044.29.6.3.209.1.2Columnpm1004mCtrlxfpLineLoopPortnread-writecurrentLine Facility Loopback :This OID operates a Line Facility Loopback, looping line input signal on the line output port. The loop is located on the line transcei…
1.3.6.1.4.1.20044.29.6.3.210Tablepm1004mCtrlxfpXfiLoopTablenot-accessiblecurrentList of pm1004mCtrlxfpXfiLoop Article
1.3.6.1.4.1.20044.29.6.3.210.1Rowpm1004mCtrlxfpXfiLoopEntrynot-accessiblecurrentRow definition for the pm1004mCtrlxfpXfiLoop table
1.3.6.1.4.1.20044.29.6.3.210.1.1Columnpm1004mCtrlxfpXfiLoopIndexread-onlycurrentIndex definition for the pm1004mCtrlxfpXfiLoop table
1.3.6.1.4.1.20044.29.6.3.210.1.2Columnpm1004mCtrlxfpXfiLoopPortnread-writecurrentLine Terminal Loopback :This OID operates a Line Terminal Loopback, looping line input signal on the line output port. The loop is located on all client transc…
1.3.6.1.4.1.20044.29.6.3.212Tablepm1004mCtrllineTunableChannelTablenot-accessiblecurrentList of pm1004mCtrllineTunableChannel Article
1.3.6.1.4.1.20044.29.6.3.212.1Rowpm1004mCtrllineTunableChannelEntrynot-accessiblecurrentRow definition for the pm1004mCtrllineTunableChannel table
1.3.6.1.4.1.20044.29.6.3.212.1.1Columnpm1004mCtrllineTunableChannelIndexread-onlycurrentIndex definition for the pm1004mCtrllineTunableChannel table
1.3.6.1.4.1.20044.29.6.3.212.1.2Columnpm1004mCtrllineTunableChannelPortnread-writecurrentITU Channel :This OID selects the ITU channel of the Line OTX TLH Laser <Help> This control defines the ITU channel of the Line OTX TLH Laser
1.3.6.1.4.1.20044.29.6.3.213Tablepm1004mCtrllinePhotodiodeModeTablenot-accessiblecurrentList of pm1004mCtrllinePhotodiodeMode Article
1.3.6.1.4.1.20044.29.6.3.213.1Rowpm1004mCtrllinePhotodiodeModeEntrynot-accessiblecurrentRow definition for the pm1004mCtrllinePhotodiodeMode table
1.3.6.1.4.1.20044.29.6.3.213.1.1Columnpm1004mCtrllinePhotodiodeModeIndexread-onlycurrentIndex definition for the pm1004mCtrllinePhotodiodeMode table
1.3.6.1.4.1.20044.29.6.3.213.1.2Columnpm1004mCtrllinePhotodiodeModePortnread-writecurrentOTX TLH Rx Sens. Mode :This OID defines the Rx sensiblity mode of the Line OTX TLH <Help> This control defines the receiver sensibility mode of the Line OTX TL…
1.3.6.1.4.1.20044.29.6.3.214Tablepm1004mCtrllinePhotodiodeValueTablenot-accessiblecurrentList of pm1004mCtrllinePhotodiodeValue Article
1.3.6.1.4.1.20044.29.6.3.214.1Rowpm1004mCtrllinePhotodiodeValueEntrynot-accessiblecurrentRow definition for the pm1004mCtrllinePhotodiodeValue table
1.3.6.1.4.1.20044.29.6.3.214.1.1Columnpm1004mCtrllinePhotodiodeValueIndexread-onlycurrentIndex definition for the pm1004mCtrllinePhotodiodeValue table
1.3.6.1.4.1.20044.29.6.3.214.1.2Columnpm1004mCtrllinePhotodiodeValuePortnread-writecurrentOTX TLH Rx Sensibility :This OID sets the Rx sensibility of the Line OTX TLH (custom mode only) <Help> This control defines the receiver sensibility value (onl…
1.3.6.1.4.1.20044.29.6.3.215Tablepm1004mCtrllinePowerLaserTablenot-accessiblecurrentList of pm1004mCtrllinePowerLaser Article
1.3.6.1.4.1.20044.29.6.3.215.1Rowpm1004mCtrllinePowerLaserEntrynot-accessiblecurrentRow definition for the pm1004mCtrllinePowerLaser table
1.3.6.1.4.1.20044.29.6.3.215.1.1Columnpm1004mCtrllinePowerLaserIndexread-onlycurrentIndex definition for the pm1004mCtrllinePowerLaser table
1.3.6.1.4.1.20044.29.6.3.215.1.2Columnpm1004mCtrllinePowerLaserPortnread-writecurrentLine Laser Output Power [3-5] :This OID sets the output power value on the laser of the Line OTX TLH (AV=Power*10+158) (Unit = dBm) <Help> This control defines…
1.3.6.1.4.1.20044.29.7Nodepm1004mri
1.3.6.1.4.1.20044.29.7.1Nodepm1004mriTable
1.3.6.1.4.1.20044.29.7.1.1Tablepm1004mRinvSfpTablenot-accessiblecurrentList of the SFPs on the selected module
1.3.6.1.4.1.20044.29.7.1.1.1Rowpm1004mRinvSfpEntrynot-accessiblecurrentRow definition for the SFP table
1.3.6.1.4.1.20044.29.7.1.1.1.1Columnpm1004mRinvSfpIndexread-onlycurrentIndex for SFP table
1.3.6.1.4.1.20044.29.7.1.1.1.2Columnpm1004mRinvsfpread-onlycurrentInventory for the SFP: This OID contains the inventory for the SFP
1.3.6.1.4.1.20044.29.7.1.2Tablepm1004mRinvLineTablenot-accessiblecurrentList of the XFPs on the selected module
1.3.6.1.4.1.20044.29.7.1.2.1Rowpm1004mRinvLineEntrynot-accessiblecurrentRow definition for the XFP table
1.3.6.1.4.1.20044.29.7.1.2.1.1Columnpm1004mRinvLineIndexread-onlycurrentIndex for XFP table
1.3.6.1.4.1.20044.29.7.1.2.1.2Columnpm1004mRinvxfpLineread-onlycurrentInventory for the XFP: This OID contains the inventory for the XFP
1.3.6.1.4.1.20044.29.7.2Scalarpm1004mRinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.29.7.3Scalarpm1004mRinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.29.7.4Scalarpm1004mRinvModulePlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.29.7.5Scalarpm1004mRinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.29.7.6Scalarpm1004mRinvGwPlatformread-onlycurrentGW platform desciption: This OID contains the description of the Gateware platform.
1.3.6.1.4.1.20044.29.8Nodepm1004mdownload
1.3.6.1.4.1.20044.29.8.1Nodepm1004mDwlOther
1.3.6.1.4.1.20044.29.8.1.0Nodepm1004mDwlrestartProcess
1.3.6.1.4.1.20044.29.8.1.0.1Scalarpm1004mDwlWarmRestartProcessedread-onlycurrentWarm Restart :This OID indicates that the module last restart was a Warm RESTART
1.3.6.1.4.1.20044.29.8.1.0.2Scalarpm1004mDwlColdRestartProcessedread-onlycurrentCold Restart :This OID indicates that the module last restart was a Cold RESTART
1.3.6.1.4.1.20044.29.8.1.1Nodepm1004mDwlswBanksUsed
1.3.6.1.4.1.20044.29.8.1.1.1Scalarpm1004mDwlSwBank1Usedread-onlycurrentSW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby
1.3.6.1.4.1.20044.29.8.1.1.2Scalarpm1004mDwlSwBank2Usedread-onlycurrentSW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby
1.3.6.1.4.1.20044.29.8.1.1.5Scalarpm1004mDwlSwBank1Notemptyread-onlycurrentSW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package
1.3.6.1.4.1.20044.29.8.1.1.6Scalarpm1004mDwlSwBank2Notemptyread-onlycurrentSW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package
1.3.6.1.4.1.20044.29.8.1.2Nodepm1004mDwlgwBanksUsed
1.3.6.1.4.1.20044.29.8.1.2.1Scalarpm1004mDwlGwBank1Usedread-onlycurrentGW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby
1.3.6.1.4.1.20044.29.8.1.2.2Scalarpm1004mDwlGwBank2Usedread-onlycurrentGW bank 2 active :This OID indicates the module is working on GW bank 2
1.3.6.1.4.1.20044.29.8.1.2.3Scalarpm1004mDwlGwBank3Usedread-onlycurrentGW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby
1.3.6.1.4.1.20044.29.8.1.2.4Scalarpm1004mDwlGwBank4Usedread-onlycurrentGW bank 4 active :This OID indicates the module is working on GW bank 4
1.3.6.1.4.1.20044.29.8.1.2.5Scalarpm1004mDwlGwBank1Notemptyread-onlycurrentGW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package
1.3.6.1.4.1.20044.29.8.1.2.6Scalarpm1004mDwlGwBank2Notemptyread-onlycurrentGW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2
1.3.6.1.4.1.20044.29.8.1.2.7Scalarpm1004mDwlGwBank3Notemptyread-onlycurrentGW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package
1.3.6.1.4.1.20044.29.8.1.2.8Scalarpm1004mDwlGwBank4Notemptyread-onlycurrentGW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4
1.3.6.1.4.1.20044.29.8.2Nodepm1004mDwlClient
1.3.6.1.4.1.20044.29.8.3Nodepm1004mDwlLine
1.3.6.1.4.1.20044.29.9Nodepm1004mConfig
1.3.6.1.4.1.20044.29.9.1Nodepm1004mCfgAccessCAisCsf
1.3.6.1.4.1.20044.29.9.1.1Tablepm1004mCfgClientcaiscsfTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.29.9.1.1.1Rowpm1004mCfgClientcaiscsfEntrynot-accessiblecurrentRow definition for the accessCAisCsf table
1.3.6.1.4.1.20044.29.9.1.1.1.1Columnpm1004mCfgClientcaiscsfIndexread-onlycurrentIndex definition for the clientcaiscsf table
1.3.6.1.4.1.20044.29.9.1.1.1.3Columnpm1004mCfgCAisModePortnread-writecurrentCAIS mode on Client Port :This register enables/disables port laser shutdown on CAIS insertion condition
1.3.6.1.4.1.20044.29.9.1.1.1.9Columnpm1004mCfgUpAccessioAlmPortnread-writecurrentCSF contributors on Client Port :This register configures the contributors to upstream CSF insertion on the port.
1.3.6.1.4.1.20044.29.9.1.1.1.10Columnpm1004mCfgUpMapperDeAlmPortnread-writecurrentCSF contributors on Client Port :This register configures the contributors to upstream CSF insertion on the port.
1.3.6.1.4.1.20044.29.9.1.1.1.11Columnpm1004mCfgUpAccessioSdhAlmPortnread-writecurrentCSF contributors on Client Port :This register selects the contributors of SDH register to upstream CAIS/CSF on Port
1.3.6.1.4.1.20044.29.9.1.1.1.17Columnpm1004mCfgDownAccessioAlmPortnread-writecurrentCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port.
1.3.6.1.4.1.20044.29.9.1.1.1.18Columnpm1004mCfgDownMapperDeAlmPortnread-writecurrentCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port.
1.3.6.1.4.1.20044.29.9.1.1.1.19Columnpm1004mCfgDownDfrmAlmPortnread-writecurrentCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port.
1.3.6.1.4.1.20044.29.9.1.1.1.20Columnpm1004mCfgDownLineSyncAlarmsPortnread-writedeprecatedCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port.
1.3.6.1.4.1.20044.29.9.1.1.1.21Columnpm1004mCfgDownAccessioSdhAlmPortnread-writecurrentCAIS contributors on Client Port :This register selects the contributors of SDH register to downstream CAIS/CSF on Port
1.3.6.1.4.1.20044.29.9.2Nodepm1004mCfgStartup
1.3.6.1.4.1.20044.29.9.2.1Tablepm1004mCfgClientStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.29.9.2.1.1Rowpm1004mCfgClientStartupEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.29.9.2.1.1.1Columnpm1004mCfgClientStartupIndexread-onlycurrentIndex definition for the clientStartup table
1.3.6.1.4.1.20044.29.9.2.1.1.3Columnpm1004mCfgSystConfPortPortnread-writecurrentDefault Settings on Client Port :This register configures the default initialisation settings on the port.
1.3.6.1.4.1.20044.29.9.2.1.1.4Columnpm1004mCfgNetConfPortPortnread-writecurrentDefault Protocol on Client Port :This register configures the default initialisation protocol on the port.
1.3.6.1.4.1.20044.29.9.2.2Nodepm1004mtablelineStartup
1.3.6.1.4.1.20044.29.9.2.2.2Scalarpm1004mCfgsystConfLine1read-writecurrentDefault Settings on Line 1 :This register configures the default initialisation settings on Line port 1.
1.3.6.1.4.1.20044.29.9.2.2.5Scalarpm1004mCfglineOptions1read-writecurrentDefault Options on Active Line Port :This register configures the default options on the active line port
1.3.6.1.4.1.20044.29.9.2.2.6Scalarpm1004mCfgsystConfLine2read-writecurrentDefault Settings on Line 2 :This register configures the default initialisation settings on Line port 2.
1.3.6.1.4.1.20044.29.9.2.2.7Scalarpm1004mCfglineSelectionread-writecurrentDefault Settings of active line :This register configures the start up active line.
1.3.6.1.4.1.20044.29.9.2.3Tablepm1004mCfgXfpTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.29.9.2.3.1Rowpm1004mCfgXfpEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.29.9.2.3.1.1Columnpm1004mCfgXfpIndexread-onlycurrentIndex definition for the xfp table
1.3.6.1.4.1.20044.29.9.2.3.1.3Columnpm1004mCfgSystConfXfpPortnread-writecurrentDefault settings on XFP Port :This register configures the default initialisation settings on XFP port.
1.3.6.1.4.1.20044.29.9.2.3.1.4Columnpm1004mCfgDataRateConfXfpPortnread-writedeprecated:Reserved
1.3.6.1.4.1.20044.29.9.3Nodepm1004mCfgLabels
1.3.6.1.4.1.20044.29.9.3.1Tablepm1004mCfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.29.9.3.1.1Rowpm1004mCfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.29.9.3.1.1.1Columnpm1004mCfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.29.9.3.1.1.3Columnpm1004mCfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.29.9.3.2Tablepm1004mCfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.29.9.3.2.1Rowpm1004mCfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.29.9.3.2.1.1Columnpm1004mCfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.29.9.3.2.1.3Columnpm1004mCfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.29.9.4Nodepm1004mCfgModPerfConfig
1.3.6.1.4.1.20044.29.9.4.1Nodepm1004mtablemodPerfConfig
1.3.6.1.4.1.20044.29.9.4.1.2Scalarpm1004mCfgperfModeread-writecurrentSONET or SDH monitoring mode :This OID defines the line monitoring mode (SONET or SDH mode)
1.3.6.1.4.1.20044.29.9.5Nodepm1004mCfgJ0Client
1.3.6.1.4.1.20044.29.9.5.1Tablepm1004mCfgEmptyTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.29.9.5.1.1Rowpm1004mCfgEmptyEntrynot-accessiblecurrentRow definition for the j0Client table
1.3.6.1.4.1.20044.29.9.5.1.1.1Columnpm1004mCfgEmptyIndexread-onlycurrentIndex definition for the empty table
1.3.6.1.4.1.20044.29.9.5.1.1.3Columnpm1004mCfgClientExpectJ0SetupPortnread-writecurrentExpected Trace Identifier mode :This register configures the Expected Trace Identifier Mode (single byte, 16 bytes with CRC7, 64 bytes with CRC7 or 64 bytes wi…
1.3.6.1.4.1.20044.29.9.6Nodepm1004mCfgStartuptlh
1.3.6.1.4.1.20044.29.9.6.1Tablepm1004mCfgOtxtlhTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.29.9.6.1.1Rowpm1004mCfgOtxtlhEntrynot-accessiblecurrentRow definition for the startuptlh table
1.3.6.1.4.1.20044.29.9.6.1.1.1Columnpm1004mCfgOtxtlhIndexread-onlycurrentIndex definition for the otxtlh table
1.3.6.1.4.1.20044.29.9.6.1.1.3Columnpm1004mCfgNuPortnread-writedeprecated:
1.3.6.1.4.1.20044.29.9.6.1.1.4Columnpm1004mCfgLineDitherRatePortnread-writecurrentDefault Line OTX TLH FM amplitude :This register configures the start-up width of the frequency modulation of the Line OTX TLH
1.3.6.1.4.1.20044.29.9.6.1.1.5Columnpm1004mCfgLineDitherFhzPortnread-writecurrentDefault Line OTX TLH FM frequency :This register configures the start-up frequency of the frequency modulation of the Line OTX TLH
1.3.6.1.4.1.20044.29.9.6.1.1.6Columnpm1004mCfgLinePwrLaserPortnread-writecurrentDefaut Line OTX TLH output Power :This register configures the start-up output power of the Line OTX TLH (Unit = dBm)
1.3.6.1.4.1.20044.29.9.6.1.1.7Columnpm1004mCfgLineFCurrentPortnread-writecurrentDefault Line OTX TLH Channel :This register configures the start-up laser channel of the Line OTX TLH
1.3.6.1.4.1.20044.29.9.6.1.1.8Columnpm1004mCfgLineGridCurrentPortnread-writecurrentDefault Line OTX TLH Grid :This register configures the start-up laser grid of the Line OTX TLH
1.3.6.1.4.1.20044.29.9.6.1.1.9Columnpm1004mCfgFPortnread-writecurrentDefault Line OTX TLH lowest Freq :This register configures the start-up lowest frequency supported on the Line OTX TLH
1.3.6.1.4.1.20044.29.9.6.1.1.10Columnpm1004mCfgReservedPortnread-writedeprecated:
1.3.6.1.4.1.20044.29.9.6.1.1.11Columnpm1004mCfgLinePhotodiodeModePortnread-writecurrentDefault Line OTX TLH APD mode :This register configures the start-up APD mode of the Line OTX TLH
1.3.6.1.4.1.20044.29.9.6.1.1.12Columnpm1004mCfgLinePhotodiodeValuePortnread-writecurrentDefault Line OTX TLH APD atten. :This register configures the start-up APD attenuation on the Line OTX TLH
1.3.6.1.4.1.20044.29.9.7Nodepm1004mCfgStartuptablefive
1.3.6.1.4.1.20044.29.9.7.1Tablepm1004mCfgOtxtlhcapabilitiesTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.29.9.7.1.1Rowpm1004mCfgOtxtlhcapabilitiesEntrynot-accessiblecurrentRow definition for the startuptablefive table
1.3.6.1.4.1.20044.29.9.7.1.1.1Columnpm1004mCfgOtxtlhcapabilitiesIndexread-onlycurrentIndex definition for the otxtlhcapabilities table
1.3.6.1.4.1.20044.29.9.7.1.1.3Columnpm1004mCfgComponentTypePortnread-onlycurrentComponent parameters :This OID defines the component parameters
1.3.6.1.4.1.20044.29.9.7.1.1.4Columnpm1004mCfgMiscellaneousPortnread-onlycurrentMiscellaneous default settings :This OID defines the miscellaneous parameters
1.3.6.1.4.1.20044.29.9.7.1.1.5Columnpm1004mCfgFirstChannelPortnread-onlycurrentNumber of the first channel of the component :This OID defines the first channel number of the PM
1.3.6.1.4.1.20044.29.9.7.1.1.6Columnpm1004mCfgLastChannelPortnread-onlycurrentNumber of the last channel of the component :This OID defines the last channel number of the PM
1.3.6.1.4.1.20044.29.9.7.1.1.7Columnpm1004mCfgGridPortnread-onlycurrentGrid value of the component :This OID defines the grid of the PM
1.3.6.1.4.1.20044.29.9.257Scalarpm1004mCfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.29.10Nodepm1004mtraps
1.3.6.1.4.1.20044.29.10.2Scalarpm1004mtrapPortNumberread-onlycurrentLast port which generates a trap
1.3.6.1.4.1.20044.29.10.3Scalarpm1004mtrapLineNumberread-onlycurrentLast Line which generates a trap
1.3.6.1.4.1.20044.29.10.4Scalarpm1004mtrapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.29.10.30Notificationpm1004mLineTrapNotUrgentGoesOncurrentNot urgent Line default is activated
1.3.6.1.4.1.20044.29.10.31Notificationpm1004mLineTrapNotUrgentGoesOffcurrentNot urgent Line default disappeared
1.3.6.1.4.1.20044.29.10.32Notificationpm1004mLineTrapUrgentGoesOncurrentUrgent Line default is activated
1.3.6.1.4.1.20044.29.10.33Notificationpm1004mLineTrapUrgentGoesOffcurrentUrgent Line default disappeared
1.3.6.1.4.1.20044.29.10.34Notificationpm1004mLineTrapCritGoesOncurrentCritical Line default is activated
1.3.6.1.4.1.20044.29.10.35Notificationpm1004mLineTrapCritGoesOffcurrentCritical Line default disappeared
1.3.6.1.4.1.20044.29.10.40Notificationpm1004mClientTrapNotUrgentGoesOncurrentNot urgent client default is activated
1.3.6.1.4.1.20044.29.10.41Notificationpm1004mClientTrapNotUrgentGoesOffcurrentNot urgent client default disappeared
1.3.6.1.4.1.20044.29.10.42Notificationpm1004mClientTrapUrgentGoesOncurrentUrgent client default is activated
1.3.6.1.4.1.20044.29.10.43Notificationpm1004mClientTrapUrgentGoesOffcurrentUrgent client default disappeared
1.3.6.1.4.1.20044.29.10.44Notificationpm1004mClientTrapCritGoesOncurrentCritical client default is activated
1.3.6.1.4.1.20044.29.10.45Notificationpm1004mClientTrapCritGoesOffcurrentCritical client default disappeared
1.3.6.1.4.1.20044.29.10.50Notificationpm1004mPowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.29.10.51Notificationpm1004mPowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared
1.3.6.1.4.1.20044.29.11Nodepm1004mMonitoring
1.3.6.1.4.1.20044.29.11.1Nodepm1004mMonOther
1.3.6.1.4.1.20044.29.11.1.1Nodepm1004mMonSync
1.3.6.1.4.1.20044.29.11.1.1.257Scalarpm1004mPerfEnableread-writecurrentPerf. Mon. Enable :This OID enables the Performance Monitoring application
1.3.6.1.4.1.20044.29.11.1.1.258Scalarpm1004mPerfSyncSourceread-writecurrentPerf. Mon. Sync. Source :This OID selects the Synchronisation source for the Performance Monitoring application (internal of external)
1.3.6.1.4.1.20044.29.11.1.1.259Scalarpm1004mPerf15minSyncread-writecurrentPerf. Mon. 15-min sync. :This OID must be used in external synchronisation mode only to send a 15-min synchronisation command
1.3.6.1.4.1.20044.29.11.1.1.260Scalarpm1004mPerf24hSyncread-writecurrentPerf. Mon. 24-hours sync. :This OID must be used in external synchronisation mode only to send a 24-hours synchronisation command
1.3.6.1.4.1.20044.29.11.1.2Nodepm1004mMonTimeStamp
1.3.6.1.4.1.20044.29.11.1.2.5Scalarpm1004mPerfCurrent15MinElapsedTimeread-writecurrentCurrent 15min period Elapsed Time :This OID gives the number of seconds elapsed in the current 15-minutes period
1.3.6.1.4.1.20044.29.11.1.2.6Scalarpm1004mPerfCurrent24HoursElapsedTimeread-writecurrentCurrent 24hours period Elapsed Time :This OID gives the number of seconds elapsed in the current 24-hours period
1.3.6.1.4.1.20044.29.11.1.2.7Scalarpm1004mPerfPast15MinElapsedTimeread-writecurrentPast 15min period Elapsed Time :This OID gives the number of seconds elapsed in the past 15-minutes period
1.3.6.1.4.1.20044.29.11.1.2.8Scalarpm1004mPerfPast24HoursElapsedTimeread-writecurrentPast 24hours period Elapsed Time :This OID gives the number of seconds elapsed in the past 24-hours period
1.3.6.1.4.1.20044.29.11.2Nodepm1004mMonClient
1.3.6.1.4.1.20044.29.11.2.1Nodepm1004mMonClientPerformance
1.3.6.1.4.1.20044.29.11.2.1.16Tablepm1004mPerfUpCurrent15CntTablenot-accessiblecurrentList of pm1004mPerfUpCurrent15Cnt Article
1.3.6.1.4.1.20044.29.11.2.1.16.1Rowpm1004mPerfUpCurrent15CntEntrynot-accessiblecurrentRow definition for the pm1004mPerfUpCurrent15Cnt table
1.3.6.1.4.1.20044.29.11.2.1.16.1.1Columnpm1004mPerfUpCurrent15CntIndexread-onlycurrentIndex definition for the pm1004mPerfUpCurrent15Cnt table
1.3.6.1.4.1.20044.29.11.2.1.16.1.2Columnpm1004mPerfUpCurrent15CntInvCvPortnread-onlycurrentCurrent 15-min CV counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.29.11.2.1.16.1.3Columnpm1004mPerfUpCurrent15CntCvValuePortnread-onlycurrentCurrent 15-min CV counter :This OID gives the current 15-min Coding Violation counter value
1.3.6.1.4.1.20044.29.11.2.1.16.1.4Columnpm1004mPerfUpCurrent15CntInvEsPortnread-onlycurrentCurrent 15-min ES counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.29.11.2.1.16.1.5Columnpm1004mPerfUpCurrent15CntEsValuePortnread-onlycurrentCurrent 15-min ES counter :This OID gives the current 15-min Errored Second counter value
1.3.6.1.4.1.20044.29.11.2.1.16.1.6Columnpm1004mPerfUpCurrent15CntInvSesPortnread-onlycurrentCurrent 15-min SES counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.29.11.2.1.16.1.7Columnpm1004mPerfUpCurrent15CntSesValuePortnread-onlycurrentCurrent 15-min SES counter :This OID gives the current 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.29.11.2.1.16.1.8Columnpm1004mPerfUpCurrent15CntInvSefsPortnread-onlycurrentCurrent 15-min SEFS counter inv. :This OID indicates that the current 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.29.11.2.1.16.1.9Columnpm1004mPerfUpCurrent15CntSefsValuePortnread-onlycurrentCurrent 15-min SEFS counter :This OID gives the current 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.29.11.2.1.16.1.10Columnpm1004mPerfUpCurrent15CntInvUasPortnread-onlycurrentCurrent 15-min UAS counter inv. :This OID indicates that the current 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.29.11.2.1.16.1.11Columnpm1004mPerfUpCurrent15CntUasValuePortnread-onlycurrentCurrent 15-min UAS counter :This OID gives the current 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.29.11.2.1.24Tablepm1004mPerfUpPast15CntTablenot-accessiblecurrentList of pm1004mPerfUpPast15Cnt Article
1.3.6.1.4.1.20044.29.11.2.1.24.1Rowpm1004mPerfUpPast15CntEntrynot-accessiblecurrentRow definition for the pm1004mPerfUpPast15Cnt table
1.3.6.1.4.1.20044.29.11.2.1.24.1.1Columnpm1004mPerfUpPast15CntIndexread-onlycurrentIndex definition for the pm1004mPerfUpPast15Cnt table
1.3.6.1.4.1.20044.29.11.2.1.24.1.2Columnpm1004mPerfUpPast15CntInvCvPortnread-onlycurrentPrevious 15-min CV counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.29.11.2.1.24.1.3Columnpm1004mPerfUpPast15CntCvValuePortnread-onlycurrentPrevious 15-min CV counter :This OID gives the previous 15-min Coding Violation counter value
1.3.6.1.4.1.20044.29.11.2.1.24.1.4Columnpm1004mPerfUpPast15CntInvEsPortnread-onlycurrentPrevious 15-min ES counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.29.11.2.1.24.1.5Columnpm1004mPerfUpPast15CntEsValuePortnread-onlycurrentPrevious 15-min ES counter :This OID gives the previous 15-min Errored Second counter value
1.3.6.1.4.1.20044.29.11.2.1.24.1.6Columnpm1004mPerfUpPast15CntInvSesPortnread-onlycurrentPrevious 15-min SES counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.29.11.2.1.24.1.7Columnpm1004mPerfUpPast15CntSesValuePortnread-onlycurrentPrevious 15-min SES counter :This OID gives the previous 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.29.11.2.1.24.1.8Columnpm1004mPerfUpPast15CntInvSefsPortnread-onlycurrentPrevious 15-min SEFS counter inv. :This OID indicates that the previous 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.29.11.2.1.24.1.9Columnpm1004mPerfUpPast15CntSefsValuePortnread-onlycurrentPrevious 15-min SEFS counter :This OID gives the previous 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.29.11.2.1.24.1.10Columnpm1004mPerfUpPast15CntInvUasPortnread-onlycurrentPrevious 15-min UAS counter inv. :This OID indicates that the previous 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.29.11.2.1.24.1.11Columnpm1004mPerfUpPast15CntUasValuePortnread-onlycurrentPrevious 15-min UAS counter :This OID gives the previous 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.29.11.2.1.32Tablepm1004mPerfUpCurrent24CntTablenot-accessiblecurrentList of pm1004mPerfUpCurrent24Cnt Article
1.3.6.1.4.1.20044.29.11.2.1.32.1Rowpm1004mPerfUpCurrent24CntEntrynot-accessiblecurrentRow definition for the pm1004mPerfUpCurrent24Cnt table
1.3.6.1.4.1.20044.29.11.2.1.32.1.1Columnpm1004mPerfUpCurrent24CntIndexread-onlycurrentIndex definition for the pm1004mPerfUpCurrent24Cnt table
1.3.6.1.4.1.20044.29.11.2.1.32.1.2Columnpm1004mPerfUpCurrent24CntInvCvPortnread-onlycurrentCurrent 24-hours CV counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.29.11.2.1.32.1.3Columnpm1004mPerfUpCurrent24CntCvValuePortnread-onlycurrentCurrent 24-hours CV counter :This OID gives the current 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.29.11.2.1.32.1.4Columnpm1004mPerfUpCurrent24CntInvEsPortnread-onlycurrentCurrent 24-hours ES counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.29.11.2.1.32.1.5Columnpm1004mPerfUpCurrent24CntEsValuePortnread-onlycurrentCurrent 24-hours ES counter :This OID gives the current 24-hours Errored Second counter value
1.3.6.1.4.1.20044.29.11.2.1.32.1.6Columnpm1004mPerfUpCurrent24CntInvSesPortnread-onlycurrentCurrent 24-hours SES counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.29.11.2.1.32.1.7Columnpm1004mPerfUpCurrent24CntSesValuePortnread-onlycurrentCurrent 24-hours SES counter :This OID gives the current 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.29.11.2.1.32.1.8Columnpm1004mPerfUpCurrent24CntInvSefsPortnread-onlycurrentCurrent 24-hours SEFS counter inv. :This OID indicates that the current 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.29.11.2.1.32.1.9Columnpm1004mPerfUpCurrent24CntSefsValuePortnread-onlycurrentCurrent 24-hours SEFS counter :This OID gives the current 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.29.11.2.1.32.1.10Columnpm1004mPerfUpCurrent24CntInvUasPortnread-onlycurrentCurrent 24-hours UAS counter inv. :This OID indicates that the current 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.29.11.2.1.32.1.11Columnpm1004mPerfUpCurrent24CntUasValuePortnread-onlycurrentCurrent 24-hours UAS counter :This OID gives the current 24-hours UnAvailable Second counter value
1.3.6.1.4.1.20044.29.11.2.1.40Tablepm1004mPerfUpPast24CntTablenot-accessiblecurrentList of pm1004mPerfUpPast24Cnt Article
1.3.6.1.4.1.20044.29.11.2.1.40.1Rowpm1004mPerfUpPast24CntEntrynot-accessiblecurrentRow definition for the pm1004mPerfUpPast24Cnt table
1.3.6.1.4.1.20044.29.11.2.1.40.1.1Columnpm1004mPerfUpPast24CntIndexread-onlycurrentIndex definition for the pm1004mPerfUpPast24Cnt table
1.3.6.1.4.1.20044.29.11.2.1.40.1.2Columnpm1004mPerfUpPast24CntInvCvPortnread-onlycurrentPrevious 24-hours CV counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.29.11.2.1.40.1.3Columnpm1004mPerfUpPast24CntCvValuePortnread-onlycurrentPrevious 24-hours CV counter :This OID gives the previous 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.29.11.2.1.40.1.4Columnpm1004mPerfUpPast24CntInvEsPortnread-onlycurrentPrevious 24-hours ES counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.29.11.2.1.40.1.5Columnpm1004mPerfUpPast24CntEsValuePortnread-onlycurrentPrevious 24-hours ES counter :This OID gives the previous 24-hours Errored Second counter value
1.3.6.1.4.1.20044.29.11.2.1.40.1.6Columnpm1004mPerfUpPast24CntInvSesPortnread-onlycurrentPrevious 24-hours SES counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.29.11.2.1.40.1.7Columnpm1004mPerfUpPast24CntSesValuePortnread-onlycurrentPrevious 24-hours SES counter :This OID gives the previous 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.29.11.2.1.40.1.8Columnpm1004mPerfUpPast24CntInvSefsPortnread-onlycurrentPrevious 24-hours SEFS counter inv. :This OID indicates that the previous 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.29.11.2.1.40.1.9Columnpm1004mPerfUpPast24CntSefsValuePortnread-onlycurrentPrevious 24-hours SEFS counter :This OID gives the previous 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.29.11.2.1.40.1.10Columnpm1004mPerfUpPast24CntInvUasPortnread-onlycurrentPrevious 24-hours UAS counter inv. :This OID indicates that the previous 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.29.11.2.1.40.1.11Columnpm1004mPerfUpPast24CntUasValuePortnread-onlycurrentPrevious 24-hours UAS counter :This OID gives the previous 24-hours UnAvailable Second counter value
1.3.6.1.4.1.20044.29.11.2.2Nodepm1004mMonClientTraceIdentifier
1.3.6.1.4.1.20044.29.11.2.2.2112Tablepm1004mAlmj0AlarmTablenot-accessiblecurrentList of pm1004mAlmj0Alarm Article
1.3.6.1.4.1.20044.29.11.2.2.2112.1Rowpm1004mAlmj0AlarmEntrynot-accessiblecurrentRow definition for the pm1004mAlmj0Alarm table
1.3.6.1.4.1.20044.29.11.2.2.2112.1.1Columnpm1004mAlmj0AlarmIndexread-onlycurrentIndex definition for the pm1004mAlmj0Alarm table
1.3.6.1.4.1.20044.29.11.2.2.2112.1.2Columnpm1004mAlmJ0TimAlarmPortnread-onlycurrentTrace Identifier Mismatch :This OID indicates a Trace Identifier Mismatch has been detected on the client input stream <Condtype> J0_TIM_ALARM_1 <Probcause> ot…
1.3.6.1.4.1.20044.29.11.2.2.2112.1.3Columnpm1004mAlmJ0TiiAlarmPortnread-onlycurrentTrace Identifier Unstable :This OID indicates the Trace Identifier is unstable on the client input stream <Condtype> J0_TII_ALARM_1 <Probcause> other (1) <Alar…
1.3.6.1.4.1.20044.29.11.2.2.2112.1.4Columnpm1004mAlmCrc7ErrorPortnread-onlycurrentCRC Error On Trace Identifier :This OID indicates that a CRC error has been detected in the stable Trace Identifier on the client input stream <Condtype> CRC7_…
1.3.6.1.4.1.20044.29.11.3Nodepm1004mMonLine
1.3.6.1.4.1.20044.29.11.3.1Nodepm1004mMonLinePerformance
1.3.6.1.4.1.20044.29.11.3.1.128Tablepm1004mPerfLineCurrent15CntTablenot-accessiblecurrentList of pm1004mPerfLineCurrent15Cnt Article
1.3.6.1.4.1.20044.29.11.3.1.128.1Rowpm1004mPerfLineCurrent15CntEntrynot-accessiblecurrentRow definition for the pm1004mPerfLineCurrent15Cnt table
1.3.6.1.4.1.20044.29.11.3.1.128.1.1Columnpm1004mPerfLineCurrent15CntIndexread-onlycurrentIndex definition for the pm1004mPerfLineCurrent15Cnt table
1.3.6.1.4.1.20044.29.11.3.1.128.1.2Columnpm1004mPerfLineCurrent15CntInvCvPortnread-onlycurrentCurrent 15-min CV counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.29.11.3.1.128.1.3Columnpm1004mPerfLineCurrent15CntCvValuePortnread-onlycurrentCurrent 15-min CV counter :This OID gives the current 15-min Coding Violation counter value
1.3.6.1.4.1.20044.29.11.3.1.128.1.4Columnpm1004mPerfLineCurrent15CntInvEsPortnread-onlycurrentCurrent 15-min ES counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.29.11.3.1.128.1.5Columnpm1004mPerfLineCurrent15CntEsValuePortnread-onlycurrentCurrent 15-min ES counter :This OID gives the current 15-min Errored Second counter value
1.3.6.1.4.1.20044.29.11.3.1.128.1.6Columnpm1004mPerfLineCurrent15CntInvSesPortnread-onlycurrentCurrent 15-min SES counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.29.11.3.1.128.1.7Columnpm1004mPerfLineCurrent15CntSesValuePortnread-onlycurrentCurrent 15-min SES counter :This OID gives the current 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.29.11.3.1.128.1.8Columnpm1004mPerfLineCurrent15CntInvSefsPortnread-onlycurrentCurrent 15-min SEFS counter inv. :This OID indicates that the current 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.29.11.3.1.128.1.9Columnpm1004mPerfLineCurrent15CntSefsValuePortnread-onlycurrentCurrent 15-min SEFS counter :This OID gives the current 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.29.11.3.1.128.1.10Columnpm1004mPerfLineCurrent15CntInvUasPortnread-onlycurrentCurrent 15-min UAS counter inv. :This OID indicates that the current 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.29.11.3.1.128.1.11Columnpm1004mPerfLineCurrent15CntUasValuePortnread-onlycurrentCurrent 15-min UAS counter :This OID gives the current 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.29.11.3.1.129Tablepm1004mPerfLinePast15CntTablenot-accessiblecurrentList of pm1004mPerfLinePast15Cnt Article
1.3.6.1.4.1.20044.29.11.3.1.129.1Rowpm1004mPerfLinePast15CntEntrynot-accessiblecurrentRow definition for the pm1004mPerfLinePast15Cnt table
1.3.6.1.4.1.20044.29.11.3.1.129.1.1Columnpm1004mPerfLinePast15CntIndexread-onlycurrentIndex definition for the pm1004mPerfLinePast15Cnt table
1.3.6.1.4.1.20044.29.11.3.1.129.1.2Columnpm1004mPerfLinePast15CntInvCvPortnread-onlycurrentPrevious 15-min CV counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.29.11.3.1.129.1.3Columnpm1004mPerfLinePast15CntCvValuePortnread-onlycurrentPrevious 15-min CV counter :This OID gives the previous 15-min Coding Violation counter value
1.3.6.1.4.1.20044.29.11.3.1.129.1.4Columnpm1004mPerfLinePast15CntInvEsPortnread-onlycurrentPrevious 15-min ES counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.29.11.3.1.129.1.5Columnpm1004mPerfLinePast15CntEsValuePortnread-onlycurrentPrevious 15-min ES counter :This OID gives the previous 15-min Errored Second counter value
1.3.6.1.4.1.20044.29.11.3.1.129.1.6Columnpm1004mPerfLinePast15CntInvSesPortnread-onlycurrentPrevious 15-min SES counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.29.11.3.1.129.1.7Columnpm1004mPerfLinePast15CntSesValuePortnread-onlycurrentPrevious 15-min SES counter :This OID gives the previous 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.29.11.3.1.129.1.8Columnpm1004mPerfLinePast15CntInvSefsPortnread-onlycurrentPrevious 15-min SEFS counter inv. :This OID indicates that the previous 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.29.11.3.1.129.1.9Columnpm1004mPerfLinePast15CntSefsValuePortnread-onlycurrentPrevious 15-min SEFS counter :This OID gives the previous 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.29.11.3.1.129.1.10Columnpm1004mPerfLinePast15CntInvUasPortnread-onlycurrentPrevious 15-min UAS counter inv. :This OID indicates that the previous 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.29.11.3.1.129.1.11Columnpm1004mPerfLinePast15CntUasValuePortnread-onlycurrentPrevious 15-min UAS counter :This OID gives the previous 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.29.11.3.1.130Tablepm1004mPerfLineCurrent24CntTablenot-accessiblecurrentList of pm1004mPerfLineCurrent24Cnt Article
1.3.6.1.4.1.20044.29.11.3.1.130.1Rowpm1004mPerfLineCurrent24CntEntrynot-accessiblecurrentRow definition for the pm1004mPerfLineCurrent24Cnt table
1.3.6.1.4.1.20044.29.11.3.1.130.1.1Columnpm1004mPerfLineCurrent24CntIndexread-onlycurrentIndex definition for the pm1004mPerfLineCurrent24Cnt table
1.3.6.1.4.1.20044.29.11.3.1.130.1.2Columnpm1004mPerfLineCurrent24CntInvCvPortnread-onlycurrentCurrent 24-hours CV counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.29.11.3.1.130.1.3Columnpm1004mPerfLineCurrent24CntCvValuePortnread-onlycurrentCurrent 24-hours CV counter :This OID gives the current 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.29.11.3.1.130.1.4Columnpm1004mPerfLineCurrent24CntInvEsPortnread-onlycurrentCurrent 24-hours ES counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.29.11.3.1.130.1.5Columnpm1004mPerfLineCurrent24CntEsValuePortnread-onlycurrentCurrent 24-hours ES counter :This OID gives the current 24-hours Errored Second counter value
1.3.6.1.4.1.20044.29.11.3.1.130.1.6Columnpm1004mPerfLineCurrent24CntInvSesPortnread-onlycurrentCurrent 24-hours SES counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.29.11.3.1.130.1.7Columnpm1004mPerfLineCurrent24CntSesValuePortnread-onlycurrentCurrent 24-hours SES counter :This OID gives the current 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.29.11.3.1.130.1.8Columnpm1004mPerfLineCurrent24CntInvSefsPortnread-onlycurrentCurrent 24-hours SEFS counter inv. :This OID indicates that the current 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.29.11.3.1.130.1.9Columnpm1004mPerfLineCurrent24CntSefsValuePortnread-onlycurrentCurrent 24-hours SEFS counter :This OID gives the current 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.29.11.3.1.130.1.10Columnpm1004mPerfLineCurrent24CntInvUasPortnread-onlycurrentCurrent 24-hours UAS counter inv. :This OID indicates that the current 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.29.11.3.1.130.1.11Columnpm1004mPerfLineCurrent24CntUasValuePortnread-onlycurrentCurrent 24-hours UAS counter :This OID gives the current 24-hours UnAvailable Second counter value
1.3.6.1.4.1.20044.29.11.3.1.131Tablepm1004mPerfLinePast24CntTablenot-accessiblecurrentList of pm1004mPerfLinePast24Cnt Article
1.3.6.1.4.1.20044.29.11.3.1.131.1Rowpm1004mPerfLinePast24CntEntrynot-accessiblecurrentRow definition for the pm1004mPerfLinePast24Cnt table
1.3.6.1.4.1.20044.29.11.3.1.131.1.1Columnpm1004mPerfLinePast24CntIndexread-onlycurrentIndex definition for the pm1004mPerfLinePast24Cnt table
1.3.6.1.4.1.20044.29.11.3.1.131.1.2Columnpm1004mPerfLinePast24CntInvCvPortnread-onlycurrentPrevious 24-hours CV counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.29.11.3.1.131.1.3Columnpm1004mPerfLinePast24CntCvValuePortnread-onlycurrentPrevious 24-hours CV counter :This OID gives the previous 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.29.11.3.1.131.1.4Columnpm1004mPerfLinePast24CntInvEsPortnread-onlycurrentPrevious 24-hours ES counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.29.11.3.1.131.1.5Columnpm1004mPerfLinePast24CntEsValuePortnread-onlycurrentPrevious 24-hours ES counter :This OID gives the previous 24-hours Errored Second counter value
1.3.6.1.4.1.20044.29.11.3.1.131.1.6Columnpm1004mPerfLinePast24CntInvSesPortnread-onlycurrentPrevious 24-hours SES counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.29.11.3.1.131.1.7Columnpm1004mPerfLinePast24CntSesValuePortnread-onlycurrentPrevious 24-hours SES counter :This OID gives the previous 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.29.11.3.1.131.1.8Columnpm1004mPerfLinePast24CntInvSefsPortnread-onlycurrentPrevious 24-hours SEFS counter inv. :This OID indicates that the previous 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.29.11.3.1.131.1.9Columnpm1004mPerfLinePast24CntSefsValuePortnread-onlycurrentPrevious 24-hours SEFS counter :This OID gives the previous 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.29.11.3.1.131.1.10Columnpm1004mPerfLinePast24CntInvUasPortnread-onlycurrentPrevious 24-hours UAS counter inv. :This OID indicates that the previous 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.29.11.3.1.131.1.11Columnpm1004mPerfLinePast24CntUasValuePortnread-onlycurrentPrevious 24-hours UAS counter :This OID gives the previous 24-hours UnAvailable Second counter value
1.3.6.1.4.1.20044.29.11.3.2Nodepm1004mMonLineTraceIdentifier
Type Definitions
NameSyntaxStatusDescription
Pm1004mAdjustValueINTEGER { otxadjustvalue0(0), otxadjustvalue1(1), otxadjustvalue2(2), otxadjustvalue3(3), otxadjustvalue4(4), otxadjustvalue5(5), otxadjustvalue6(6), otxadjustvalue7(7), otxadjustvalue8(8), otxadjustvalue9(9), otxadjustvalue10(10), }currentDifferent values in Adjust mode on OTX-TLH on client and line ports
Pm1004mOtxChannelINTEGER { }currentChannel selection on OTX-TLH on client and line ports
Pm1004mOtxGridINTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50), }currentDifferent grids on OTX-TLH on client and line ports
Pm1004mOtxModeINTEGER { otx80mode(1), otx60mode(2), otxadjustmode(4), }currentDifferent modes on OTX-TLH on client and line ports