MIB for managing Ekinops modules with PM1004VENC software
OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.43IdentitymodulePm1004vencMIB for managing Ekinops modules with PM1004VENC software
1.3.6.1.4.1.20044.43.2Nodepm1004vencalarms
1.3.6.1.4.1.20044.43.2.1Nodepm1004vencAlmOther
1.3.6.1.4.1.20044.43.2.1.1Nodepm1004vencAlmOtherNurg
1.3.6.1.4.1.20044.43.2.1.1.2Nodepm1004vencAlmsynthAlm2
1.3.6.1.4.1.20044.43.2.1.1.2.1Scalarpm1004vencAlmConfTableSaveread-onlycurrentPM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> other…
1.3.6.1.4.1.20044.43.2.1.1.2.2Scalarpm1004vencAlmInvUploadread-onlycurrentInventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> other (1) <Alarmtype> other (1) <Polarit…
1.3.6.1.4.1.20044.43.2.1.1.2.3Scalarpm1004vencAlmConfTableLoadread-onlycurrentPM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> other (1) <Alarmt…
1.3.6.1.4.1.20044.43.2.1.1.2.4Scalarpm1004vencAlmCorrelatOffread-onlycurrentNot Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> other (1) <Alarmtype> other (1) <Pol…
1.3.6.1.4.1.20044.43.2.1.1.2.5Scalarpm1004vencAlmMaintenanceOnread-onlycurrentMaintenance Mode :This OID indicates that the PM is in maintenance mode. <Help> This alarm indicates that the maintenance mode is enabled on the PM <Condtype> …
1.3.6.1.4.1.20044.43.2.1.2Nodepm1004vencAlmOtherUrg
1.3.6.1.4.1.20044.43.2.1.2.194Nodepm1004vencAlmmodInitFailLevel2
1.3.6.1.4.1.20044.43.2.1.2.194.1Scalarpm1004vencAlmLedFailread-onlycurrentLed Fail :This OID indicates that Led register has not been correctly initalized <Help> This alarm indicates if the module LEDs are correctly initialized <Cond…
1.3.6.1.4.1.20044.43.2.1.2.194.2Scalarpm1004vencAlmNextColdBootForcedread-onlycurrentNext Cold Boot Forced :This OID indicates that the next Reset will be forced Cold <Help> This alarm indicates that the next reset of the module will be forced …
1.3.6.1.4.1.20044.43.2.1.2.194.3Scalarpm1004vencAlmBootUndoneread-onlycurrentBoot Undone :This OID indicates that the boot has not been correctly achieved <Help> This alarm indicates if the module has correctly boot <Condtype> BOOT_UNDO…
1.3.6.1.4.1.20044.43.2.1.2.194.4Scalarpm1004vencAlmResetHwInitFailread-onlycurrentReset HW Init Fail :This OID indicates that the HW intialization has caused unknown intial conditions <Help> This alarm indicates if the HW has been correctly …
1.3.6.1.4.1.20044.43.2.1.2.194.5Scalarpm1004vencAlmSwInitFailread-onlycurrentSW Init Fail :This OID indicates that the SW intialization has caused unknown intial conditions <Help> This alarm indicates if the SW module is correctly initi…
1.3.6.1.4.1.20044.43.2.1.2.195Nodepm1004vencAlmmodInitFailLevel3
1.3.6.1.4.1.20044.43.2.1.2.195.1Scalarpm1004vencAlmGwIdentFailread-onlycurrentGW Ident Fail :This OID indicates that GW identification has not been read <Help> This alarm indicates if the GW has been correctly identified <Condtype> GW_ID…
1.3.6.1.4.1.20044.43.2.1.2.195.2Scalarpm1004vencAlmObmTypeReadFailread-onlycurrentOBM Type Read Fail :This OID indicates that OBM type has not been recognized <Help> This alarm indicates if the OBM board has been correctly identified <Condty…
1.3.6.1.4.1.20044.43.2.1.2.195.3Scalarpm1004vencAlmInitModuleFailread-onlycurrentInit Module Fail :This OID indicates that the Module has not been correctly initialized <Help> This alarm indicates if the SW module is correctly initialized <…
1.3.6.1.4.1.20044.43.2.1.2.195.5Scalarpm1004vencAlmXfp1InitFailread-onlycurrentXFP1 Init Fail :This OID indicates that the XFP has not been correctly initialized <Help> This alarm indicates if the line transceiver 1 is correctly initializ…
1.3.6.1.4.1.20044.43.2.1.2.195.6Scalarpm1004vencAlmXfp2InitFailread-onlycurrentXFP2 Init Fail :This OID indicates that the XFP has not been correctly initialized <Help> This alarm indicates if the line transceiver 2 is correctly initializ…
1.3.6.1.4.1.20044.43.2.1.2.195.7Scalarpm1004vencAlmLine1InitFailread-onlycurrentLine1 Init Fail :This OID indicates that the Line registersvsubset has not been correctly initialized <Help> This alarm indicates if the line port 1 is correct…
1.3.6.1.4.1.20044.43.2.1.2.195.8Scalarpm1004vencAlmLine2InitFailread-onlycurrentLine2 Init Fail :This OID indicates that the Line register subset has not been correctly initialized <Help> This alarm indicates if the line port 2 is correctl…
1.3.6.1.4.1.20044.43.2.1.2.195.9Scalarpm1004vencAlmClient1InitFailread-onlycurrentClient1 Init Fail :This OID indicates that Client 1 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 1 is cor…
1.3.6.1.4.1.20044.43.2.1.2.195.10Scalarpm1004vencAlmClient2InitFailread-onlycurrentClient2 Init Fail :This OID indicates that Client 2 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 2 is cor…
1.3.6.1.4.1.20044.43.2.1.2.195.11Scalarpm1004vencAlmClient3InitFailread-onlycurrentClient3 Init Fail :This OID indicates that Client 3 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 3 is cor…
1.3.6.1.4.1.20044.43.2.1.2.195.12Scalarpm1004vencAlmClient4InitFailread-onlycurrentClient4 Init Fail :This OID indicates that Client 4 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 4 is cor…
1.3.6.1.4.1.20044.43.2.1.2.198Nodepm1004vencAlmclientRxProt
1.3.6.1.4.1.20044.43.2.1.2.198.1Scalarpm1004vencAlmAdddropClient1Westread-onlycurrentClient West Rx Side Active :This OID indicates the Client is active on West receiving side <Condtype> ADDDROP_CLIENT1_WEST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.43.2.1.2.198.2Scalarpm1004vencAlmAdddropClient2Westread-onlycurrentClient West Rx Side Active :This OID indicates the Client is active on West receiving side <Condtype> ADDDROP_CLIENT2_WEST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.43.2.1.2.198.3Scalarpm1004vencAlmAdddropClient3Westread-onlycurrentClient West Rx Side Active :This OID indicates the Client is active on West receiving side <Condtype> ADDDROP_CLIENT3_WEST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.43.2.1.2.198.4Scalarpm1004vencAlmAdddropClient4Westread-onlycurrentClient West Rx Side Active :This OID indicates the Client is active on West receiving side <Condtype> ADDDROP_CLIENT4_WEST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.43.2.1.2.198.9Scalarpm1004vencAlmAdddropClient1Eastread-onlycurrentClient East Rx Side Active :This OID indicates the Client is active on East receiving side <Condtype> ADDDROP_CLIENT1_EAST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.43.2.1.2.198.10Scalarpm1004vencAlmAdddropClient2Eastread-onlycurrentClient East Rx Side Active :This OID indicates the Client is active on East receiving side <Condtype> ADDDROP_CLIENT2_EAST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.43.2.1.2.198.11Scalarpm1004vencAlmAdddropClient3Eastread-onlycurrentClient East Rx Side Active :This OID indicates the Client is active on East receiving side <Condtype> ADDDROP_CLIENT3_EAST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.43.2.1.2.198.12Scalarpm1004vencAlmAdddropClient4Eastread-onlycurrentClient East Rx Side Active :This OID indicates the Client is active on East receiving side <Condtype> ADDDROP_CLIENT4_EAST <Probcause> other (1) <Alarmtype> ot…
1.3.6.1.4.1.20044.43.2.1.2.199Nodepm1004vencAlmmodOther
1.3.6.1.4.1.20044.43.2.1.2.199.1Scalarpm1004vencAlmAesDecodFailread-onlycurrentAES Decoding Failure :This OID indicates the AES Decoding process failed. <Help> This alarm indicates the AES Decoding process failed. <Condtype> AES_DECOD_FAI…
1.3.6.1.4.1.20044.43.2.1.3Nodepm1004vencAlmOtherCrit
1.3.6.1.4.1.20044.43.2.1.3.0Nodepm1004vencAlmsynthAlm0
1.3.6.1.4.1.20044.43.2.1.3.0.9Scalarpm1004vencAlmModGlobFailread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the PM <Condtype> MOD_GLOB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> sy…
1.3.6.1.4.1.20044.43.2.1.3.0.15Scalarpm1004vencAlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.43.2.1.3.0.16Scalarpm1004vencAlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.43.2.2Nodepm1004vencAlmClient
1.3.6.1.4.1.20044.43.2.2.1Nodepm1004vencAlmClientNurg
1.3.6.1.4.1.20044.43.2.2.2Nodepm1004vencAlmClientUrg
1.3.6.1.4.1.20044.43.2.2.3Nodepm1004vencAlmClientCrit
1.3.6.1.4.1.20044.43.2.2.3.8Tablepm1004vencAlmsynthAlmPortTablenot-accessiblecurrentList of pm1004vencAlmsynthAlmPort Article
1.3.6.1.4.1.20044.43.2.2.3.8.1Rowpm1004vencAlmsynthAlmPortEntrynot-accessiblecurrentRow definition for the pm1004vencAlmsynthAlmPort table
1.3.6.1.4.1.20044.43.2.2.3.8.1.1Columnpm1004vencAlmsynthAlmPortIndexread-onlycurrentIndex definition for the pm1004vencAlmsynthAlmPort table
1.3.6.1.4.1.20044.43.2.2.3.8.1.5Columnpm1004vencAlmHwFailAccPortnread-onlycurrentClient HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Condtype> HW_FAIL_ACC_1 <Probcause> equipmentMalfunction (16)…
1.3.6.1.4.1.20044.43.2.2.3.8.1.6Columnpm1004vencAlmDwLsdPortnread-onlycurrentClient Signal Shutdown :This OID indicates the Client SFP transmitter output is ON. <Help> This status indicates if the client transceiver is ON or OFF <Condty…
1.3.6.1.4.1.20044.43.2.2.3.8.1.7Columnpm1004vencAlmClientLocalOosTxPortnread-onlycurrentTx Client Port In Service :This OID indicates that the local Tx Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local T…
1.3.6.1.4.1.20044.43.2.2.3.8.1.8Columnpm1004vencAlmClientLocalOosRxPortnread-onlycurrentRx Client Port In Service :This OID indicates that the local Rx Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local R…
1.3.6.1.4.1.20044.43.2.2.3.8.1.9Columnpm1004vencAlmDwCaisPortnread-onlycurrentClient AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indictaes if a Client Alarm Indication Signal is…
1.3.6.1.4.1.20044.43.2.2.3.8.1.13Columnpm1004vencAlmFailAccPortnread-onlycurrentClient Access Fail :This OID indicates a failure on the Client port <Condtype> FAIL_ACC_1 <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12)…
1.3.6.1.4.1.20044.43.2.2.3.8.1.17Columnpm1004vencAlmUpCsfPortnread-onlycurrentClient Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu…
1.3.6.1.4.1.20044.43.2.2.3.16Tablepm1004vencAlmaccessioAlmTablenot-accessiblecurrentList of pm1004vencAlmaccessioAlm Article
1.3.6.1.4.1.20044.43.2.2.3.16.1Rowpm1004vencAlmaccessioAlmEntrynot-accessiblecurrentRow definition for the pm1004vencAlmaccessioAlm table
1.3.6.1.4.1.20044.43.2.2.3.16.1.1Columnpm1004vencAlmaccessioAlmIndexread-onlycurrentIndex definition for the pm1004vencAlmaccessioAlm table
1.3.6.1.4.1.20044.43.2.2.3.16.1.5Columnpm1004vencAlmUpLosPortnread-onlycurrentClient Input Loss Of Signal :This OID indicates that no signal is present on the client port <Help> This alarm indicates if a signal is detected on the client …
1.3.6.1.4.1.20044.43.2.2.3.72Tablepm1004vencAlmmapperDeAlmTablenot-accessiblecurrentList of pm1004vencAlmmapperDeAlm Article
1.3.6.1.4.1.20044.43.2.2.3.72.1Rowpm1004vencAlmmapperDeAlmEntrynot-accessiblecurrentRow definition for the pm1004vencAlmmapperDeAlm table
1.3.6.1.4.1.20044.43.2.2.3.72.1.1Columnpm1004vencAlmmapperDeAlmIndexread-onlycurrentIndex definition for the pm1004vencAlmmapperDeAlm table
1.3.6.1.4.1.20044.43.2.2.3.72.1.2Columnpm1004vencAlmUpAccOosPortnread-onlycurrentClient Loss Of Synchro :This OID indicates the upstream client input port has lost synchronization on its decoder <Help> This alarms indicates if the input cli…
1.3.6.1.4.1.20044.43.2.2.3.72.1.11Columnpm1004vencAlmUpBufferOvlPortnread-onlycurrentClient Upstream Buffer Overload :This OID indicates that the rate adaptation buffer for client port is in overload. <Help> This alarm indicates if there is a u…
1.3.6.1.4.1.20044.43.2.2.3.72.1.12Columnpm1004vencAlmDwCsfDetPortnread-onlycurrentClient Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client…
1.3.6.1.4.1.20044.43.2.2.3.72.1.15Columnpm1004vencAlmDwBufferOvlPortnread-onlycurrentClient Downstream Buffer Overload :This OID indicates that the de-mapper buffer for client port is in overload. <Help> This alarm indicates if there is a downs…
1.3.6.1.4.1.20044.43.2.2.3.112Tablepm1004vencAlmvideoProtocolStatusTablenot-accessiblecurrentList of pm1004vencAlmvideoProtocolStatus Article
1.3.6.1.4.1.20044.43.2.2.3.112.1Rowpm1004vencAlmvideoProtocolStatusEntrynot-accessiblecurrentRow definition for the pm1004vencAlmvideoProtocolStatus table
1.3.6.1.4.1.20044.43.2.2.3.112.1.1Columnpm1004vencAlmvideoProtocolStatusIndexread-onlycurrentIndex definition for the pm1004vencAlmvideoProtocolStatus table
1.3.6.1.4.1.20044.43.2.2.3.112.1.2Columnpm1004vencAlmSdiTxPortnread-onlycurrentSDI Detected On Tx :This OID indicates that the SDI protocol has been detected on the transmit side of the port (only significant on Video2 to Video 5 ports) <…
1.3.6.1.4.1.20044.43.2.2.3.112.1.3Columnpm1004vencAlmHdSdiPalTxPortnread-onlycurrentHD-SDI-PAL Detected On Tx :This OID indicates that the HD-SDI-PAL protocol has been detected on the transmit side of the port (only significant on Video2 to Vi…
1.3.6.1.4.1.20044.43.2.2.3.112.1.4Columnpm1004vencAlmHdSdiNtscTxPortnread-onlycurrentHD-SDI-NTSC Detected On Tx :This OID indicates that the HD-SDI-NTSC protocol has been detected on the transmit side of the port (only significant on Video2 to …
1.3.6.1.4.1.20044.43.2.2.3.112.1.5Columnpm1004vencAlmDvbAsiTxPortnread-onlycurrentDVB-ASI Detected On Tx :This OID indicates that the DVB-ASI protocol has been detected on the transmit side of the port (only significant on Video2 to Video 5 …
1.3.6.1.4.1.20044.43.2.2.3.112.1.10Columnpm1004vencAlmSdiRxPortnread-onlycurrentSDI Detected On Rx :This OID indicates that the SDI protocol has been detected on the receive side of the port (only significant on Video2 to Video 5 ports) <H…
1.3.6.1.4.1.20044.43.2.2.3.112.1.11Columnpm1004vencAlmHdSdiPalRxPortnread-onlycurrentHD-SDI-PAL Detected On Rx :This OID indicates that the HD-SDI-PAL protocol has been detected on the receive side of the port (only significant on Video2 to Vid…
1.3.6.1.4.1.20044.43.2.2.3.112.1.12Columnpm1004vencAlmHdSdiNtscRxPortnread-onlycurrentHD-SDI-NTSC Detected On Rx :This OID indicates that the HD-SDI-NTSC protocol has been detected on the receive side of the port (only significant on Video2 to V…
1.3.6.1.4.1.20044.43.2.2.3.112.1.13Columnpm1004vencAlmDvbAsiRxPortnread-onlycurrentDVB-ASI Detected On Rx :This OID indicates that the DVB-ASI protocol has been detected on the receive side of the port (only significant on Video2 to Video 5 p…
1.3.6.1.4.1.20044.43.2.3Nodepm1004vencAlmLine
1.3.6.1.4.1.20044.43.2.3.1Nodepm1004vencAlmLineNurg
1.3.6.1.4.1.20044.43.2.3.1.209Tablepm1004vencAlmlineXfp1WarningsTablenot-accessiblecurrentList of pm1004vencAlmlineXfp1Warnings Article
1.3.6.1.4.1.20044.43.2.3.1.209.1Rowpm1004vencAlmlineXfp1WarningsEntrynot-accessiblecurrentRow definition for the pm1004vencAlmlineXfp1Warnings table
1.3.6.1.4.1.20044.43.2.3.1.209.1.1Columnpm1004vencAlmlineXfp1WarningsIndexread-onlycurrentIndex definition for the pm1004vencAlmlineXfp1Warnings table
1.3.6.1.4.1.20044.43.2.3.1.209.1.2Columnpm1004vencAlmTxPowerLowWarningPortnread-onlycurrentLine Optical Tx Power Low Warning :Warning indicating that the XFP/OTX transmitter transmitter output power is lower than the threshold value written in the XF…
1.3.6.1.4.1.20044.43.2.3.1.209.1.3Columnpm1004vencAlmTxPowerHighWarningPortnread-onlycurrentLine Optical Tx Power High Warning :Warning indicating that the XFP/OTX transmitter transmitter output power is higher than the threshold value written in the …
1.3.6.1.4.1.20044.43.2.3.1.209.1.4Columnpm1004vencAlmTxBiasLowWarningPortnread-onlycurrentLine Transceiver Bias Low Warning :Warning indicating that the XFP/OTX transmitter laser bias current is lower than the threshold value written in the XFP/OTX …
1.3.6.1.4.1.20044.43.2.3.1.209.1.5Columnpm1004vencAlmTxBiasHighWarningPortnread-onlycurrentLine Transceiver Bias High Warning :Warning indicating that the XFP/OTX transmitter laser bias current is higher than the threshold value written in the XFP EE…
1.3.6.1.4.1.20044.43.2.3.1.209.1.8Columnpm1004vencAlmTempLowWarningPortnread-onlycurrentLine Transceiver Temp Low Warning :Warning indicating that the XFP/OTX temperature is lower than the threshold value written in the XFP/OTX EEPROM <Condtype> T…
1.3.6.1.4.1.20044.43.2.3.1.209.1.9Columnpm1004vencAlmTempHighWarningPortnread-onlycurrentLine Transceiver Temp High Warning :Warning indicating that the XFP/OTX temperature is higher than the threshold value written in the XFP EEPROM <Condtype> TEM…
1.3.6.1.4.1.20044.43.2.3.1.209.1.16Columnpm1004vencAlmRxPowerLowWarningPortnread-onlycurrentLine Optical Rx Power Low Warning :Warning indicating that the XFP received optical power is lower than the threshold value written in the XFP EEPROM <Condtype…
1.3.6.1.4.1.20044.43.2.3.1.209.1.17Columnpm1004vencAlmRxPowerHighWarningPortnread-onlycurrentLine Optical Rx Power High Warning :Warning indicating that the XFP received optical power is higher than the threshold value written in the XFP EEPROM <Condty…
1.3.6.1.4.1.20044.43.2.3.1.225Tablepm1004vencAlmlineOtx1TlhWarningsTablenot-accessiblecurrentList of pm1004vencAlmlineOtx1TlhWarnings Article
1.3.6.1.4.1.20044.43.2.3.1.225.1Rowpm1004vencAlmlineOtx1TlhWarningsEntrynot-accessiblecurrentRow definition for the pm1004vencAlmlineOtx1TlhWarnings table
1.3.6.1.4.1.20044.43.2.3.1.225.1.1Columnpm1004vencAlmlineOtx1TlhWarningsIndexread-onlycurrentIndex definition for the pm1004vencAlmlineOtx1TlhWarnings table
1.3.6.1.4.1.20044.43.2.3.1.225.1.6Columnpm1004vencAlmLineModulatorAgingHighWarningPortnread-onlycurrentLine Modulator Aging High Warning :Warning indicating the Line OTX TLH modulator aging is higher than the threshold written in the EEPROM <Condtype> LINE_MODUL…
1.3.6.1.4.1.20044.43.2.3.1.225.1.7Columnpm1004vencAlmLineAgingHighWarningPortnread-onlycurrentLine OTX TLH Aging High Warning :Warning indicating the Line OTX TLH aging is higher than the threshold written in the EEPROM <Condtype> LINE_AGING_HIGH_WARNIN…
1.3.6.1.4.1.20044.43.2.3.1.225.1.13Columnpm1004vencAlmLineFreqDevHighWarningPortnread-onlycurrentLine Freq. Deviation High Warning :Warning indicating the Line OTX TLH frequency deviation is higher than the threshold written in the EEPROM <Condtype> LINE_F…
1.3.6.1.4.1.20044.43.2.3.1.225.1.15Columnpm1004vencAlmLineLaserTempHighWarningPortnread-onlycurrentLine Laser Temp. High Warning :Warning indicating the Line OTX TLH laser temperature is higher than the threshold written in the EEPROM <Condtype> LINE_LASER_T…
1.3.6.1.4.1.20044.43.2.3.2Nodepm1004vencAlmLineUrg
1.3.6.1.4.1.20044.43.2.3.2.208Tablepm1004vencAlmlineXfp1AlarmTablenot-accessiblecurrentList of pm1004vencAlmlineXfp1Alarm Article
1.3.6.1.4.1.20044.43.2.3.2.208.1Rowpm1004vencAlmlineXfp1AlarmEntrynot-accessiblecurrentRow definition for the pm1004vencAlmlineXfp1Alarm table
1.3.6.1.4.1.20044.43.2.3.2.208.1.1Columnpm1004vencAlmlineXfp1AlarmIndexread-onlycurrentIndex definition for the pm1004vencAlmlineXfp1Alarm table
1.3.6.1.4.1.20044.43.2.3.2.208.1.2Columnpm1004vencAlmTxPowerLowAlarmPortnread-onlycurrentLine Optical Tx Power Low :Alarm indicating that the XFP/OTX transmitter transmitter output power is lower than the threshold value written in the XFP/OTX EEPR…
1.3.6.1.4.1.20044.43.2.3.2.208.1.3Columnpm1004vencAlmTxPowerHighAlarmPortnread-onlycurrentLine Optical Tx Power High :Alarm indicating that the XFP/OTX transmitter transmitter output power is higher than the threshold value written in the XFP EEPROM…
1.3.6.1.4.1.20044.43.2.3.2.208.1.4Columnpm1004vencAlmTxBiasLowAlarmPortnread-onlycurrentLine Transceiver Bias Low :Alarm indicating that the XFP/OTX transmitter laser bias current is lower than the threshold value written in the XFP/OTX EEPROM <Co…
1.3.6.1.4.1.20044.43.2.3.2.208.1.5Columnpm1004vencAlmTxBiasHighAlarmPortnread-onlycurrentLine Transceiver Bias High :Alarm indicating that the XFP/OTX transmitter laser bias current is higher than the threshold value written in the XFP EEPROM <Cond…
1.3.6.1.4.1.20044.43.2.3.2.208.1.8Columnpm1004vencAlmTempLowAlarmPortnread-onlycurrentLine Transceiver Temp Low :Alarm indicating that the XFP/OTX temperature is lower than the threshold value written in the XFP/OTX EEPROM <Condtype> TEMP_LOW_AL…
1.3.6.1.4.1.20044.43.2.3.2.208.1.9Columnpm1004vencAlmTempHighAlarmPortnread-onlycurrentLine Transceiver Temp High :Alarm indicating that the XFP/OTX temperature is higher than the threshold value written in the XFP EEPROM <Condtype> TEMP_HIGH_ALA…
1.3.6.1.4.1.20044.43.2.3.2.208.1.16Columnpm1004vencAlmRxPowerLowAlarmPortnread-onlycurrentLine Optical Rx Power Low :Alarm indicating that the XFP received optical power is lower than the threshold value written in the XFP EEPROM <Condtype> RX_POWER…
1.3.6.1.4.1.20044.43.2.3.2.208.1.17Columnpm1004vencAlmRxPowerHighAlarmPortnread-onlycurrentLine Optical Rx Power High :Alarm indicating that the XFP received optical power is higher than the threshold value written in the XFP EEPROM <Condtype> RX_POW…
1.3.6.1.4.1.20044.43.2.3.2.210Tablepm1004vencAlmlineXfp1CritTablenot-accessiblecurrentList of pm1004vencAlmlineXfp1Crit Article
1.3.6.1.4.1.20044.43.2.3.2.210.1Rowpm1004vencAlmlineXfp1CritEntrynot-accessiblecurrentRow definition for the pm1004vencAlmlineXfp1Crit table
1.3.6.1.4.1.20044.43.2.3.2.210.1.1Columnpm1004vencAlmlineXfp1CritIndexread-onlycurrentIndex definition for the pm1004vencAlmlineXfp1Crit table
1.3.6.1.4.1.20044.43.2.3.2.210.1.2Columnpm1004vencAlmTxPowerLowCritPortnread-onlycurrentLine Custom Tx Power Low :Custom Alarm indicating that the XFP/OTX output power of port is lower than the custom threshold defined in configuration <Help> Cust…
1.3.6.1.4.1.20044.43.2.3.2.210.1.3Columnpm1004vencAlmTxPowerHighCritPortnread-onlycurrentLine Custom Tx Power High :Custom Alarm indicating that the XFP/OTX output power of port is higher than the custom threshold defined in configuration <Help> Cu…
1.3.6.1.4.1.20044.43.2.3.2.210.1.16Columnpm1004vencAlmRxPowerLowCritPortnread-onlycurrentLine Custom Rx Power Low :Custom Alarm indicating that the XFP/OTX input power of port is lower than the custom threshold defined in configuration <Help> Custo…
1.3.6.1.4.1.20044.43.2.3.2.210.1.17Columnpm1004vencAlmRxPowerHighCritPortnread-onlycurrentLine Custom Rx Power High :Custom Alarm indicating that the XFP/OTX input power of port is higher than the custom threshold defined in configuration <Help> Cus…
1.3.6.1.4.1.20044.43.2.3.2.212Tablepm1004vencAlmlineXfp1SupplyAlarmTablenot-accessiblecurrentList of pm1004vencAlmlineXfp1SupplyAlarm Article
1.3.6.1.4.1.20044.43.2.3.2.212.1Rowpm1004vencAlmlineXfp1SupplyAlarmEntrynot-accessiblecurrentRow definition for the pm1004vencAlmlineXfp1SupplyAlarm table
1.3.6.1.4.1.20044.43.2.3.2.212.1.1Columnpm1004vencAlmlineXfp1SupplyAlarmIndexread-onlycurrentIndex definition for the pm1004vencAlmlineXfp1SupplyAlarm table
1.3.6.1.4.1.20044.43.2.3.2.212.1.2Columnpm1004vencAlmVee5LowAlarmPortnread-onlycurrentVEE5 Power Supply Low :Alarm indicating the XFP/OTX VEE5 power supply is lower than the threshold written in the EEPROM <Condtype> VEE5_LOW_ALARM_1 <Probcause>…
1.3.6.1.4.1.20044.43.2.3.2.212.1.3Columnpm1004vencAlmVee5HighAlarmPortnread-onlycurrentVEE5 Power Supply High :Alarm indicating the XFP/OTX VEE5 power supply is higher than the threshold written in the EEPROM <Condtype> VEE5_HIGH_ALARM_1 <Probcau…
1.3.6.1.4.1.20044.43.2.3.2.212.1.4Columnpm1004vencAlmVcc2LowAlarmPortnread-onlycurrentVCC2 Power Supply Low :Alarm indicating the XFP/OTX VCC2 power supply is lower than the threshold written in the EEPROM <Condtype> VCC2_LOW_ALARM_1 <Probcause>…
1.3.6.1.4.1.20044.43.2.3.2.212.1.5Columnpm1004vencAlmVcc2HighAlarmPortnread-onlycurrentVCC2 Power Supply High :Alarm indicating the XFP/OTX VCC2 power supply is higher than the threshold written in the EEPROM <Condtype> VCC2_HIGH_ALARM_1 <Probcau…
1.3.6.1.4.1.20044.43.2.3.2.212.1.6Columnpm1004vencAlmVcc3LowAlarmPortnread-onlycurrentVCC3 Power Supply Low :Alarm indicating the XFP/OTX VCC3 power supply is lower than the threshold written in the EEPROM <Condtype> VCC3_LOW_ALARM_1 <Probcause>…
1.3.6.1.4.1.20044.43.2.3.2.212.1.7Columnpm1004vencAlmVcc3HighAlarmPortnread-onlycurrentVCC3 Power Supply High :Alarm indicating the XFP/OTX VCC3 power supply is higher than the threshold written in the EEPROM <Condtype> VCC3_HIGH_ALARM_1 <Probcau…
1.3.6.1.4.1.20044.43.2.3.2.212.1.8Columnpm1004vencAlmVcc5LowAlarmPortnread-onlycurrentVCC5 Power Supply Low :Alarm indicating the XFP/OTX VCC5 power supply is lower than the threshold written in the EEPROM <Condtype> VCC5_LOW_ALARM_1 <Probcause>…
1.3.6.1.4.1.20044.43.2.3.2.212.1.9Columnpm1004vencAlmVcc5HighAlarmPortnread-onlycurrentVCC5 Power Supply High :Alarm indicating the XFP/OTX VCC5 power supply is higher than the threshold written in the EEPROM <Condtype> VCC5_HIGH_ALARM_1 <Probcau…
1.3.6.1.4.1.20044.43.2.3.2.212.1.10Columnpm1004vencAlmVee5LowWarningPortnread-onlycurrentVEE5 Power Supply Low Warning :Warning indicating the XFP/OTX VEE5 power supply is lower than the threshold written in the EEPROM <Condtype> VEE5_LOW_WARNING_1…
1.3.6.1.4.1.20044.43.2.3.2.212.1.11Columnpm1004vencAlmVee5HighWarningPortnread-onlycurrentVEE5 Power Supply High Warning :Warning indicating the XFP/OTX VEE5 power supply is higher than the threshold written in the EEPROM <Condtype> VEE5_HIGH_WARNIN…
1.3.6.1.4.1.20044.43.2.3.2.212.1.12Columnpm1004vencAlmVcc2LowWarningPortnread-onlycurrentVCC2 Power Supply Low Warning :Warning indicating the XFP/OTX VCC2 power supply is lower than the threshold written in the EEPROM <Condtype> VCC2_LOW_WARNING_1…
1.3.6.1.4.1.20044.43.2.3.2.212.1.13Columnpm1004vencAlmVcc2HighWarningPortnread-onlycurrentVCC2 Power Supply High Warning :Warning indicating the XFP/OTX VCC2 power supply is higher than the threshold written in the EEPROM <Condtype> VCC2_HIGH_WARNIN…
1.3.6.1.4.1.20044.43.2.3.2.212.1.14Columnpm1004vencAlmVcc3LowWarningPortnread-onlycurrentVCC3 Power Supply Low Warning :Warning indicating the XFP/OTX VCC3 power supply is lower than the threshold written in the EEPROM <Condtype> VCC3_LOW_WARNING_1…
1.3.6.1.4.1.20044.43.2.3.2.212.1.15Columnpm1004vencAlmVcc3HighWarningPortnread-onlycurrentVCC3 Power Supply High Warning :Warning indicating the XFP/OTX VCC3 power supply is higher than the threshold written in the EEPROM <Condtype> VCC3_HIGH_WARNIN…
1.3.6.1.4.1.20044.43.2.3.2.212.1.16Columnpm1004vencAlmVcc5LowWarningPortnread-onlycurrentVCC5 Power Supply Low Warning :Warning indicating the XFP/OTX VCC5 power supply is lower than the threshold written in the EEPROM <Condtype> VCC5_LOW_WARNING_1…
1.3.6.1.4.1.20044.43.2.3.2.212.1.17Columnpm1004vencAlmVcc5HighWarningPortnread-onlycurrentVCC5 Power Supply High Warning :Warning indicating the XFP/OTX VCC5 power supply is higher than the threshold written in the EEPROM <Condtype> VCC5_HIGH_WARNIN…
1.3.6.1.4.1.20044.43.2.3.2.224Tablepm1004vencAlmlineOtx1TlhAlarmsTablenot-accessiblecurrentList of pm1004vencAlmlineOtx1TlhAlarms Article
1.3.6.1.4.1.20044.43.2.3.2.224.1Rowpm1004vencAlmlineOtx1TlhAlarmsEntrynot-accessiblecurrentRow definition for the pm1004vencAlmlineOtx1TlhAlarms table
1.3.6.1.4.1.20044.43.2.3.2.224.1.1Columnpm1004vencAlmlineOtx1TlhAlarmsIndexread-onlycurrentIndex definition for the pm1004vencAlmlineOtx1TlhAlarms table
1.3.6.1.4.1.20044.43.2.3.2.224.1.6Columnpm1004vencAlmLineModulatorAgingHighAlaPortnread-onlycurrentLine Modulator Aging High Alarm :Alarm indicating the Line OTX TLH modulator aging is higher than the threshold written in the EEPROM <Condtype> LINE_MODULATOR…
1.3.6.1.4.1.20044.43.2.3.2.224.1.7Columnpm1004vencAlmLineAgingHighAlaPortnread-onlycurrentLine OTX TLH Aging High Alarm :Alarm indicating the Line OTX TLH aging is higher than the threshold written in the EEPROM <Condtype> LINE_AGING_HIGH_ALA_1
1.3.6.1.4.1.20044.43.2.3.2.224.1.13Columnpm1004vencAlmLineFreqDevHighAlaPortnread-onlycurrentLine Freq. Deviation High Alarm :Alarm indicating the Line OTX TLH frequency deviation is higher than the threshold written in the EEPROM <Condtype> LINE_FREQ_…
1.3.6.1.4.1.20044.43.2.3.2.224.1.15Columnpm1004vencAlmLineLaserTempHighAlaPortnread-onlycurrentLine Laser Temp. High Alarm :Alarm indicating the Line OTX TLH laser temperature is higher than the threshold written in the EEPROM <Condtype> LINE_LASER_TEMP_…
1.3.6.1.4.1.20044.43.2.3.3Nodepm1004vencAlmLineCrit
1.3.6.1.4.1.20044.43.2.3.3.7Tablepm1004vencAlmsynthAlmLineTablenot-accessiblecurrentList of pm1004vencAlmsynthAlmLine Article
1.3.6.1.4.1.20044.43.2.3.3.7.1Rowpm1004vencAlmsynthAlmLineEntrynot-accessiblecurrentRow definition for the pm1004vencAlmsynthAlmLine table
1.3.6.1.4.1.20044.43.2.3.3.7.1.1Columnpm1004vencAlmsynthAlmLineIndexread-onlycurrentIndex definition for the pm1004vencAlmsynthAlmLine table
1.3.6.1.4.1.20044.43.2.3.3.7.1.2Columnpm1004vencAlmXfpAbsentPortnread-onlycurrentLine Optical Module Absent :This OID indicates that the line optical interface (XFP or OTX) is not plugged in. <Help> This alarm indicates if the line transcei…
1.3.6.1.4.1.20044.43.2.3.3.7.1.3Columnpm1004vencAlmXfpInitNotComplPortnread-onlycurrentLine Optical Module Ready :This OID indicates that the optical interface (XFP or OTX) is not operational. <Help> This status indicates if the line transceiver …
1.3.6.1.4.1.20044.43.2.3.3.7.1.5Columnpm1004vencAlmLineHwFailPortnread-onlycurrentLine Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Condtype> LINE_HW_FAIL <Probcause> equipmentMalfunction (1…
1.3.6.1.4.1.20044.43.2.3.3.7.1.6Columnpm1004vencAlmXfpTxOffPortnread-onlycurrentLine Optical Module Laser Shutdown :This OID indicates the line optical output power is on <Help> This status indicates if the line transceiver laser is ON or …
1.3.6.1.4.1.20044.43.2.3.3.7.1.7Columnpm1004vencAlmLineLocalOosPortnread-onlycurrentLine Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service…
1.3.6.1.4.1.20044.43.2.3.3.7.1.10Columnpm1004vencAlmLineDdmWarningPortnread-onlycurrentWarning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Warni…
1.3.6.1.4.1.20044.43.2.3.3.7.1.11Columnpm1004vencAlmLineDdmAlmPortnread-onlycurrentAlarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Alarm ha…
1.3.6.1.4.1.20044.43.2.3.3.7.1.12Columnpm1004vencAlmLineDdmCritPortnread-onlycurrentCustom Alarm On Line XFP/OTX DDM :This OID indicates a Custom alarm is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Cu…
1.3.6.1.4.1.20044.43.2.3.3.7.1.13Columnpm1004vencAlmLineFailPortnread-onlycurrentLine Port Failure :This OID indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12) <Po…
1.3.6.1.4.1.20044.43.2.3.3.7.1.17Columnpm1004vencAlmLineActivePortnread-onlycurrentLine Active :This bit indicates the line #n is active on receive side <Help> This status indicates whether the line is active or standby. <Condtype> LINE_ACTIV…
1.3.6.1.4.1.20044.43.2.3.3.128Tablepm1004vencAlmdfrmAlmTablenot-accessiblecurrentList of pm1004vencAlmdfrmAlm Article
1.3.6.1.4.1.20044.43.2.3.3.128.1Rowpm1004vencAlmdfrmAlmEntrynot-accessiblecurrentRow definition for the pm1004vencAlmdfrmAlm table
1.3.6.1.4.1.20044.43.2.3.3.128.1.1Columnpm1004vencAlmdfrmAlmIndexread-onlycurrentIndex definition for the pm1004vencAlmdfrmAlm table
1.3.6.1.4.1.20044.43.2.3.3.128.1.5Columnpm1004vencAlmLineLossofsyncPortnread-onlycurrentLoss Of Synchronisation :This OID indicates the upstream line input port is in Loss of Synchronization. <Help> This alarms indicates if the input signal is cor…
1.3.6.1.4.1.20044.43.2.3.3.133Tablepm1004vencAlmlineSyncAlarmsTablenot-accessiblecurrentList of pm1004vencAlmlineSyncAlarms Article
1.3.6.1.4.1.20044.43.2.3.3.133.1Rowpm1004vencAlmlineSyncAlarmsEntrynot-accessiblecurrentRow definition for the pm1004vencAlmlineSyncAlarms table
1.3.6.1.4.1.20044.43.2.3.3.133.1.1Columnpm1004vencAlmlineSyncAlarmsIndexread-onlycurrentIndex definition for the pm1004vencAlmlineSyncAlarms table
1.3.6.1.4.1.20044.43.2.3.3.133.1.13Columnpm1004vencAlmDwLockerrPortnread-onlycurrentDownstream Clock Lock Error :This OID indicates that the deserializer input 10 Gb/s clock recovery is not locked. <Condtype> DW_LOCKERR <Probcause> receiveFail…
1.3.6.1.4.1.20044.43.2.3.3.133.1.14Columnpm1004vencAlmUpLockerrPortnread-onlycurrentUpstream Clock Lock Error :This OID indicates that the serializer output 10 Gb/s clock multiplier unit is not locked. <Condtype> UP_LOCKERR <Probcause> receive…
1.3.6.1.4.1.20044.43.2.3.3.133.1.17Columnpm1004vencAlmDwLosPortnread-onlycurrentLine Input Loss Of Signal :This OID indicates a loss of signal on the 10 Gb/s input. <Help> This alarm indicates if an optical signal is detected on the line t…
1.3.6.1.4.1.20044.43.2.3.3.211Tablepm1004vencAlmlineXfp1AlarmsTablenot-accessiblecurrentList of pm1004vencAlmlineXfp1Alarms Article
1.3.6.1.4.1.20044.43.2.3.3.211.1Rowpm1004vencAlmlineXfp1AlarmsEntrynot-accessiblecurrentRow definition for the pm1004vencAlmlineXfp1Alarms table
1.3.6.1.4.1.20044.43.2.3.3.211.1.1Columnpm1004vencAlmlineXfp1AlarmsIndexread-onlycurrentIndex definition for the pm1004vencAlmlineXfp1Alarms table
1.3.6.1.4.1.20044.43.2.3.3.211.1.3Columnpm1004vencAlmModNrPortnread-onlycurrentLine Optical Module Not Ready :This OID indicates that the module is unable to determine correct data. <Help> This alarm indicates if the line transceiver is r…
1.3.6.1.4.1.20044.43.2.3.3.211.1.4Columnpm1004vencAlmRxCdrNotLockedPortnread-onlycurrentLine Optical Rx CDR Unlocked :This OID indicates that a loss of lock on the receiving side CDR has been detected <Help> This alarm indicates if the Rx CDR is l…
1.3.6.1.4.1.20044.43.2.3.3.211.1.6Columnpm1004vencAlmRxNrPortnread-onlycurrentLine Optical Rx Not Ready :This OID indicates that a condition has arisen leading to invalid data on the receiving side. <Help> This alarm indicates if the Rx …
1.3.6.1.4.1.20044.43.2.3.3.211.1.7Columnpm1004vencAlmTxCdrNotLockedPortnread-onlycurrentLine Optical Tx CDR Unlocked :This OID indicates a loss of lock on the transmitting side CDR has been detected. <Help> This alarm indicates if the Tx CDR is lo…
1.3.6.1.4.1.20044.43.2.3.3.211.1.8Columnpm1004vencAlmTxFaultPortnread-onlycurrentLine Optical Tx Failure :This OID indicates a fault condition on the laser detected by the safety syste <Help> This alarm indicates if the laser of the line tr…
1.3.6.1.4.1.20044.43.2.3.3.211.1.9Columnpm1004vencAlmTxNrPortnread-onlycurrentLine Optical Tx Not Ready :This OID indicates a condition has arisen leading to invalid data on the transmitting side <Help> This alarm indicates if the Tx par…
1.3.6.1.4.1.20044.43.2.3.3.211.1.15Columnpm1004vencAlmWavelengthUnlockedPortnread-onlycurrentLine Optical Tx Wavelength Unlocked :This OID indicates that the wavelength error is exceeding the manufacturer tolerance <Help> This alarm indicates if the wa…
1.3.6.1.4.1.20044.43.2.3.3.211.1.16Columnpm1004vencAlmTecFaultPortnread-onlycurrentLine Optical Tx Temp Regul Failed :This OID indicates a failure on the TEC module <Help> This alarm indicates if the TEC of the line transceiver is in fail con…
1.3.6.1.4.1.20044.43.2.3.3.211.1.17Columnpm1004vencAlmApdSupplyFaultPortnread-onlycurrentLine Rx Photodiode Power Failed :This OID indicates a failure on the APD power supply <Help> This alarm indicates if the APD power supply is in fail condition …
1.3.6.1.4.1.20044.43.3Nodepm1004vencmeasures
1.3.6.1.4.1.20044.43.3.1Nodepm1004vencMesrOther
1.3.6.1.4.1.20044.43.3.1.0Scalarpm1004vencMesrsynth0read-onlydeprecatedNot Used :This OID gives the unit used on AUX1 measurement of XFP#1 (Unit = )
1.3.6.1.4.1.20044.43.3.1.1Scalarpm1004vencMesrsynth1read-onlydeprecatedNot Used :This OID gives the unit used on AUX2 measurement of XFP#1 (Unit = )
1.3.6.1.4.1.20044.43.3.2Nodepm1004vencMesrClient
1.3.6.1.4.1.20044.43.3.3Nodepm1004vencMesrLine
1.3.6.1.4.1.20044.43.3.3.208Tablepm1004vencMesrxfp1LxModTempMeasTablenot-accessiblecurrentList of pm1004vencMesrxfp1LxModTempMeas Article
1.3.6.1.4.1.20044.43.3.3.208.1Rowpm1004vencMesrxfp1LxModTempMeasEntrynot-accessiblecurrentRow definition for the pm1004vencMesrxfp1LxModTempMeas table
1.3.6.1.4.1.20044.43.3.3.208.1.1Columnpm1004vencMesrxfp1LxModTempMeasIndexread-onlycurrentIndex definition for the pm1004vencMesrxfp1LxModTempMeas table
1.3.6.1.4.1.20044.43.3.3.208.1.2Columnpm1004vencMesrxfp1LxModTempMeasPortnread-onlycurrentLine Optical Module Temperature :This OID gives the temperature of the XFP or OTX plugged in line#n, read from the DDM (Digital Diagnostic Monitoring) (Tempera…
1.3.6.1.4.1.20044.43.3.3.209Tablepm1004vencMesrxfp1ReservedTablenot-accessibledeprecatedList of pm1004vencMesrxfp1Reserved Article
1.3.6.1.4.1.20044.43.3.3.209.1Rowpm1004vencMesrxfp1ReservedEntrynot-accessibledeprecatedRow definition for the pm1004vencMesrxfp1Reserved table
1.3.6.1.4.1.20044.43.3.3.209.1.1Columnpm1004vencMesrxfp1ReservedIndexread-onlydeprecatedIndex definition for the pm1004vencMesrxfp1Reserved table
1.3.6.1.4.1.20044.43.3.3.209.1.2Columnpm1004vencMesrxfp1ReservedPortnread-onlydeprecatedNot Used :Reserved
1.3.6.1.4.1.20044.43.3.3.210Tablepm1004vencMesrxfp1LoBiasCurrentMeasTablenot-accessiblecurrentList of pm1004vencMesrxfp1LoBiasCurrentMeas Article
1.3.6.1.4.1.20044.43.3.3.210.1Rowpm1004vencMesrxfp1LoBiasCurrentMeasEntrynot-accessiblecurrentRow definition for the pm1004vencMesrxfp1LoBiasCurrentMeas table
1.3.6.1.4.1.20044.43.3.3.210.1.1Columnpm1004vencMesrxfp1LoBiasCurrentMeasIndexread-onlycurrentIndex definition for the pm1004vencMesrxfp1LoBiasCurrentMeas table
1.3.6.1.4.1.20044.43.3.3.210.1.2Columnpm1004vencMesrxfp1LoBiasCurrentMeasPortnread-onlycurrentLine Optical Module Laser Bias :This OID gives the bias value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Bias = A…
1.3.6.1.4.1.20044.43.3.3.211Tablepm1004vencMesrxfp1LoTxPowerMeasTablenot-accessiblecurrentList of pm1004vencMesrxfp1LoTxPowerMeas Article
1.3.6.1.4.1.20044.43.3.3.211.1Rowpm1004vencMesrxfp1LoTxPowerMeasEntrynot-accessiblecurrentRow definition for the pm1004vencMesrxfp1LoTxPowerMeas table
1.3.6.1.4.1.20044.43.3.3.211.1.1Columnpm1004vencMesrxfp1LoTxPowerMeasIndexread-onlycurrentIndex definition for the pm1004vencMesrxfp1LoTxPowerMeas table
1.3.6.1.4.1.20044.43.3.3.211.1.2Columnpm1004vencMesrxfp1LoTxPowerMeasPortnread-onlycurrentLine Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (…
1.3.6.1.4.1.20044.43.3.3.212Tablepm1004vencMesrxfp1LiRxPowerMeasTablenot-accessiblecurrentList of pm1004vencMesrxfp1LiRxPowerMeas Article
1.3.6.1.4.1.20044.43.3.3.212.1Rowpm1004vencMesrxfp1LiRxPowerMeasEntrynot-accessiblecurrentRow definition for the pm1004vencMesrxfp1LiRxPowerMeas table
1.3.6.1.4.1.20044.43.3.3.212.1.1Columnpm1004vencMesrxfp1LiRxPowerMeasIndexread-onlycurrentIndex definition for the pm1004vencMesrxfp1LiRxPowerMeas table
1.3.6.1.4.1.20044.43.3.3.212.1.2Columnpm1004vencMesrxfp1LiRxPowerMeasPortnread-onlycurrentLine Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (P…
1.3.6.1.4.1.20044.43.3.3.213Tablepm1004vencMesrxfp1LxAux1MeasTablenot-accessibledeprecatedList of pm1004vencMesrxfp1LxAux1Meas Article
1.3.6.1.4.1.20044.43.3.3.213.1Rowpm1004vencMesrxfp1LxAux1MeasEntrynot-accessibledeprecatedRow definition for the pm1004vencMesrxfp1LxAux1Meas table
1.3.6.1.4.1.20044.43.3.3.213.1.1Columnpm1004vencMesrxfp1LxAux1MeasIndexread-onlydeprecatedIndex definition for the pm1004vencMesrxfp1LxAux1Meas table
1.3.6.1.4.1.20044.43.3.3.213.1.2Columnpm1004vencMesrxfp1LxAux1MeasPortnread-onlydeprecatedNot Used :This OID gives the receive power value read in the DDM (Digital Diagnostic Monitoring) of the XFP or OTX plugged in line #n (Unit = ?)
1.3.6.1.4.1.20044.43.3.3.214Tablepm1004vencMesrxfp1LxAux2MeasTablenot-accessibledeprecatedList of pm1004vencMesrxfp1LxAux2Meas Article
1.3.6.1.4.1.20044.43.3.3.214.1Rowpm1004vencMesrxfp1LxAux2MeasEntrynot-accessibledeprecatedRow definition for the pm1004vencMesrxfp1LxAux2Meas table
1.3.6.1.4.1.20044.43.3.3.214.1.1Columnpm1004vencMesrxfp1LxAux2MeasIndexread-onlydeprecatedIndex definition for the pm1004vencMesrxfp1LxAux2Meas table
1.3.6.1.4.1.20044.43.3.3.214.1.2Columnpm1004vencMesrxfp1LxAux2MeasPortnread-onlydeprecatedNot Used :This OID gives the receive power value read in the DDM (Digital Diagnostic Monitoring) of the XFP or OTX plugged in line #n (Unit = ?)
1.3.6.1.4.1.20044.43.3.3.224Tablepm1004vencMesrotx1AgingTablenot-accessiblecurrentList of pm1004vencMesrotx1Aging Article
1.3.6.1.4.1.20044.43.3.3.224.1Rowpm1004vencMesrotx1AgingEntrynot-accessiblecurrentRow definition for the pm1004vencMesrotx1Aging table
1.3.6.1.4.1.20044.43.3.3.224.1.1Columnpm1004vencMesrotx1AgingIndexread-onlycurrentIndex definition for the pm1004vencMesrotx1Aging table
1.3.6.1.4.1.20044.43.3.3.224.1.2Columnpm1004vencMesrotx1AgingPortnread-onlycurrentLine OTX TLH Aging :This OID gives the aging of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Aging = AV) (Unit = %) <Help> This measure…
1.3.6.1.4.1.20044.43.3.3.225Tablepm1004vencMesrotx1LaserTemperatureTablenot-accessibledeprecatedList of pm1004vencMesrotx1LaserTemperature Article
1.3.6.1.4.1.20044.43.3.3.225.1Rowpm1004vencMesrotx1LaserTemperatureEntrynot-accessibledeprecatedRow definition for the pm1004vencMesrotx1LaserTemperature table
1.3.6.1.4.1.20044.43.3.3.225.1.1Columnpm1004vencMesrotx1LaserTemperatureIndexread-onlydeprecatedIndex definition for the pm1004vencMesrotx1LaserTemperature table
1.3.6.1.4.1.20044.43.3.3.225.1.2Columnpm1004vencMesrotx1LaserTemperaturePortnread-onlydeprecatedLine OTX TLH Laser Temperature :This OID gives the laser temperature of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/2…
1.3.6.1.4.1.20044.43.3.3.226Tablepm1004vencMesrotx1FreqDeviationTablenot-accessiblecurrentList of pm1004vencMesrotx1FreqDeviation Article
1.3.6.1.4.1.20044.43.3.3.226.1Rowpm1004vencMesrotx1FreqDeviationEntrynot-accessiblecurrentRow definition for the pm1004vencMesrotx1FreqDeviation table
1.3.6.1.4.1.20044.43.3.3.226.1.1Columnpm1004vencMesrotx1FreqDeviationIndexread-onlycurrentIndex definition for the pm1004vencMesrotx1FreqDeviation table
1.3.6.1.4.1.20044.43.3.3.226.1.2Columnpm1004vencMesrotx1FreqDeviationPortnread-onlycurrentLine OTX TLH Frequency Deviation :This OID gives the frequency deviation of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Deviation = (A…
1.3.6.1.4.1.20044.43.3.3.227Tablepm1004vencMesrotx1LaserWvlengthTablenot-accessiblecurrentList of pm1004vencMesrotx1LaserWvlength Article
1.3.6.1.4.1.20044.43.3.3.227.1Rowpm1004vencMesrotx1LaserWvlengthEntrynot-accessiblecurrentRow definition for the pm1004vencMesrotx1LaserWvlength table
1.3.6.1.4.1.20044.43.3.3.227.1.1Columnpm1004vencMesrotx1LaserWvlengthIndexread-onlycurrentIndex definition for the pm1004vencMesrotx1LaserWvlength table
1.3.6.1.4.1.20044.43.3.3.227.1.2Columnpm1004vencMesrotx1LaserWvlengthPortnread-onlycurrentLine Optical Module Wavelength :This OID gives the laser wavelength of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Wavelength=29979245…
1.3.6.1.4.1.20044.43.4Nodepm1004venccounters
1.3.6.1.4.1.20044.43.4.1Nodepm1004vencCntOther
1.3.6.1.4.1.20044.43.4.2Nodepm1004vencCntClient
1.3.6.1.4.1.20044.43.4.3Nodepm1004vencCntLine
1.3.6.1.4.1.20044.43.4.3.152Tablepm1004vencCntdfrmB1ErrCntTablenot-accessiblecurrentList of pm1004vencCntdfrmB1ErrCnt Article
1.3.6.1.4.1.20044.43.4.3.152.1Rowpm1004vencCntdfrmB1ErrCntEntrynot-accessiblecurrentRow definition for the pm1004vencCntdfrmB1ErrCnt table
1.3.6.1.4.1.20044.43.4.3.152.1.1Columnpm1004vencCntdfrmB1ErrCntIndexread-onlycurrentIndex definition for the pm1004vencCntdfrmB1ErrCnt table
1.3.6.1.4.1.20044.43.4.3.152.1.2Columnpm1004vencCntdfrmB1ErrCntValuePortnread-onlycurrentLine Input SM-BIP8 Errors :This counter is incremented each time a B1 error is detected on the Deframer input stream. <Help> This counter gives the number of B…
1.3.6.1.4.1.20044.43.4.3.152.1.3Columnpm1004vencCntdfrmB1ErrCntErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the B1 error counter value is invalid on Port
1.3.6.1.4.1.20044.43.4.3.152.1.4Columnpm1004vencCntdfrmB1ErrCntOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a B1 error counter overload on Port
1.3.6.1.4.1.20044.43.4.3.153Tablepm1004vencCntdfrmTimCntTablenot-accessiblecurrentList of pm1004vencCntdfrmTimCnt Article
1.3.6.1.4.1.20044.43.4.3.153.1Rowpm1004vencCntdfrmTimCntEntrynot-accessiblecurrentRow definition for the pm1004vencCntdfrmTimCnt table
1.3.6.1.4.1.20044.43.4.3.153.1.1Columnpm1004vencCntdfrmTimCntIndexread-onlycurrentIndex definition for the pm1004vencCntdfrmTimCnt table
1.3.6.1.4.1.20044.43.4.3.153.1.2Columnpm1004vencCntdfrmTimCntValuePortnread-onlycurrentLine Timer Counter :This is the timing counter dedicated to the downstream deframer counters. It is incremented every 125 us.
1.3.6.1.4.1.20044.43.4.3.153.1.3Columnpm1004vencCntdfrmTimCntErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.43.4.3.153.1.4Columnpm1004vencCntdfrmTimCntOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.43.4.259Scalarpm1004vencCntCountersResetread-writecurrentCounters Reset:This OID resets and restarts all the counters
1.3.6.1.4.1.20044.43.4.260Scalarpm1004vencCntCountersStopread-writecurrentCounters stop:This OID stops all the counters
1.3.6.1.4.1.20044.43.6Nodepm1004venccontrolsWrite
1.3.6.1.4.1.20044.43.6.1Nodepm1004vencCtrlOther
1.3.6.1.4.1.20044.43.6.1.1Nodepm1004vencCtrlconfMgnt1
1.3.6.1.4.1.20044.43.6.1.1.1Scalarpm1004vencCtrlConf1Load1read-writecurrentLoad Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM.
1.3.6.1.4.1.20044.43.6.1.1.2Scalarpm1004vencCtrlConf2Load1read-writecurrentLoad Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM.
1.3.6.1.4.1.20044.43.6.1.1.10Scalarpm1004vencCtrlConf2Flash1read-writecurrentWrite Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura…
1.3.6.1.4.1.20044.43.6.1.1.14Scalarpm1004vencCtrlConf2Clear1read-writecurrentClear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o…
1.3.6.1.4.1.20044.43.6.1.4Nodepm1004vencCtrlsynth4
1.3.6.1.4.1.20044.43.6.1.4.1Scalarpm1004vencCtrlCorrelatOnread-writecurrentEnable Alarm Correlation :This OID enables the alarm correlation in the PM.
1.3.6.1.4.1.20044.43.6.1.4.2Scalarpm1004vencCtrlCorrelatOffread-writecurrentDisable Alarm Correlation :This OID disables the alarm correlation in the PM.
1.3.6.1.4.1.20044.43.6.1.5Nodepm1004vencCtrlswMgnt
1.3.6.1.4.1.20044.43.6.1.5.2Scalarpm1004vencCtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> …
1.3.6.1.4.1.20044.43.6.1.5.3Scalarpm1004vencCtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th…
1.3.6.1.4.1.20044.43.6.1.5.5Scalarpm1004vencCtrlLoadSwBank1read-writecurrentSet Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW…
1.3.6.1.4.1.20044.43.6.1.5.6Scalarpm1004vencCtrlLoadSwBank2read-writecurrentSet Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S…
1.3.6.1.4.1.20044.43.6.1.6Nodepm1004vencCtrlgwMgnt
1.3.6.1.4.1.20044.43.6.1.6.1Scalarpm1004vencCtrlCurrentGwResetread-writecurrentActive Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting.
1.3.6.1.4.1.20044.43.6.1.6.5Scalarpm1004vencCtrlLoadGwBank1read-writecurrentSet Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.43.6.1.6.6Scalarpm1004vencCtrlLoadGwBank2read-writecurrentSet Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.43.6.1.6.7Scalarpm1004vencCtrlLoadGwBank3read-writecurrentSet Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.43.6.1.6.8Scalarpm1004vencCtrlLoadGwBank4read-writecurrentSet Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.43.6.1.192Nodepm1004vencCtrlledTest
1.3.6.1.4.1.20044.43.6.1.192.1Scalarpm1004vencCtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.43.6.1.192.2Scalarpm1004vencCtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.43.6.1.192.3Scalarpm1004vencCtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.43.6.1.193Nodepm1004vencCtrlmoduleOosMode
1.3.6.1.4.1.20044.43.6.1.193.1Scalarpm1004vencCtrlModuleOosModeread-writecurrentPM Out Of Service :This OID sets the PM Out Of Service <Help> This control defines the service state of the complete module
1.3.6.1.4.1.20044.43.6.1.197Nodepm1004vencCtrlmaintenanceMode
1.3.6.1.4.1.20044.43.6.1.197.1Scalarpm1004vencCtrlMaintenanceModeread-writecurrentEnable Maintenance :This OID enables the maintenance mode on the PM. <Help> This control enables the maintenance mode on the PM.
1.3.6.1.4.1.20044.43.6.1.200Scalarpm1004vencCtrlencryptionSelectread-writecurrentEncryption Key Selection :This OID selects the key (first key:0 or second key:1) to use to encrypt/decrypt the video stream. <Help> This control selects the ke…
1.3.6.1.4.1.20044.43.6.2Nodepm1004vencCtrlClient
1.3.6.1.4.1.20044.43.6.2.16Tablepm1004vencCtrlaccessLoopTablenot-accessiblecurrentList of pm1004vencCtrlaccessLoop Article
1.3.6.1.4.1.20044.43.6.2.16.1Rowpm1004vencCtrlaccessLoopEntrynot-accessiblecurrentRow definition for the pm1004vencCtrlaccessLoop table
1.3.6.1.4.1.20044.43.6.2.16.1.1Columnpm1004vencCtrlaccessLoopIndexread-onlycurrentIndex definition for the pm1004vencCtrlaccessLoop table
1.3.6.1.4.1.20044.43.6.2.16.1.2Columnpm1004vencCtrlaccessLoopPortnread-writecurrentClient Facility Loopback :This OID operates a Client Facility Loopback, looping client input signal on the client output port. The loop is located on the clien…
1.3.6.1.4.1.20044.43.6.2.18Tablepm1004vencCtrlportOosModeTablenot-accessiblecurrentList of pm1004vencCtrlportOosMode Article
1.3.6.1.4.1.20044.43.6.2.18.1Rowpm1004vencCtrlportOosModeEntrynot-accessiblecurrentRow definition for the pm1004vencCtrlportOosMode table
1.3.6.1.4.1.20044.43.6.2.18.1.1Columnpm1004vencCtrlportOosModeIndexread-onlycurrentIndex definition for the pm1004vencCtrlportOosMode table
1.3.6.1.4.1.20044.43.6.2.18.1.2Columnpm1004vencCtrlportOosModePortnread-writecurrentClient Out Of Service :This OID sets the Service state of the client port (In Service, Tx Out of Service, Rx Out of Service or Port (Rx and Tx) Out of Service)…
1.3.6.1.4.1.20044.43.6.2.20Tablepm1004vencCtrlsfpOffCtrlTablenot-accessiblecurrentList of pm1004vencCtrlsfpOffCtrl Article
1.3.6.1.4.1.20044.43.6.2.20.1Rowpm1004vencCtrlsfpOffCtrlEntrynot-accessiblecurrentRow definition for the pm1004vencCtrlsfpOffCtrl table
1.3.6.1.4.1.20044.43.6.2.20.1.1Columnpm1004vencCtrlsfpOffCtrlIndexread-onlycurrentIndex definition for the pm1004vencCtrlsfpOffCtrl table
1.3.6.1.4.1.20044.43.6.2.20.1.2Columnpm1004vencCtrlsfpOffCtrlPortnread-writecurrentSignal OFF :This OID switches off the SFP. <Help> This control defines the laser state of the client transceiver
1.3.6.1.4.1.20044.43.6.2.21Tablepm1004vencCtrlcsfUpInsTablenot-accessiblecurrentList of pm1004vencCtrlcsfUpIns Article
1.3.6.1.4.1.20044.43.6.2.21.1Rowpm1004vencCtrlcsfUpInsEntrynot-accessiblecurrentRow definition for the pm1004vencCtrlcsfUpIns table
1.3.6.1.4.1.20044.43.6.2.21.1.1Columnpm1004vencCtrlcsfUpInsIndexread-onlycurrentIndex definition for the pm1004vencCtrlcsfUpIns table
1.3.6.1.4.1.20044.43.6.2.21.1.2Columnpm1004vencCtrlcsfUpInsPortnread-writecurrentClient Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo…
1.3.6.1.4.1.20044.43.6.2.22Tablepm1004vencCtrlcaisDwInsTablenot-accessiblecurrentList of pm1004vencCtrlcaisDwIns Article
1.3.6.1.4.1.20044.43.6.2.22.1Rowpm1004vencCtrlcaisDwInsEntrynot-accessiblecurrentRow definition for the pm1004vencCtrlcaisDwIns table
1.3.6.1.4.1.20044.43.6.2.22.1.1Columnpm1004vencCtrlcaisDwInsIndexread-onlycurrentIndex definition for the pm1004vencCtrlcaisDwIns table
1.3.6.1.4.1.20044.43.6.2.22.1.2Columnpm1004vencCtrlcaisDwInsPortnread-writecurrentClient AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port
1.3.6.1.4.1.20044.43.6.2.26Tablepm1004vencCtrlclientAccessTermLoopTablenot-accessiblecurrentList of pm1004vencCtrlclientAccessTermLoop Article
1.3.6.1.4.1.20044.43.6.2.26.1Rowpm1004vencCtrlclientAccessTermLoopEntrynot-accessiblecurrentRow definition for the pm1004vencCtrlclientAccessTermLoop table
1.3.6.1.4.1.20044.43.6.2.26.1.1Columnpm1004vencCtrlclientAccessTermLoopIndexread-onlycurrentIndex definition for the pm1004vencCtrlclientAccessTermLoop table
1.3.6.1.4.1.20044.43.6.2.26.1.2Columnpm1004vencCtrlclientAccessTermLoopPortnread-writecurrentClient Terminal Loopback :This OID operates a Client Terminal Loopback, looping client input signal on the client output port. The loop is located on the line …
1.3.6.1.4.1.20044.43.6.2.43Tablepm1004vencCtrlrxVideoProtocolTablenot-accessiblecurrentList of pm1004vencCtrlrxVideoProtocol Article
1.3.6.1.4.1.20044.43.6.2.43.1Rowpm1004vencCtrlrxVideoProtocolEntrynot-accessiblecurrentRow definition for the pm1004vencCtrlrxVideoProtocol table
1.3.6.1.4.1.20044.43.6.2.43.1.1Columnpm1004vencCtrlrxVideoProtocolIndexread-onlycurrentIndex definition for the pm1004vencCtrlrxVideoProtocol table
1.3.6.1.4.1.20044.43.6.2.43.1.2Columnpm1004vencCtrlrxVideoProtocolPortnread-writecurrentForce DVB ASI On RX Side :This OID selects the DVB ASI protocol on the client port and disable the auto-sensing feature <Help> This control selects the DVB ASI…
1.3.6.1.4.1.20044.43.6.2.128Tablepm1004vencCtrladddropClientRxProtectTablenot-accessiblecurrentList of pm1004vencCtrladddropClientRxProtect Article
1.3.6.1.4.1.20044.43.6.2.128.1Rowpm1004vencCtrladddropClientRxProtectEntrynot-accessiblecurrentRow definition for the pm1004vencCtrladddropClientRxProtect table
1.3.6.1.4.1.20044.43.6.2.128.1.1Columnpm1004vencCtrladddropClientRxProtectIndexread-onlycurrentIndex definition for the pm1004vencCtrladddropClientRxProtect table
1.3.6.1.4.1.20044.43.6.2.128.1.2Columnpm1004vencCtrladddropClientRxProtectPortnread-writecurrentClient Switch Mode :This bit selects the manual (1) or automatic (0) switch method <Help> This control defines the protection switch mode on the client interfa…
1.3.6.1.4.1.20044.43.6.2.136Tablepm1004vencCtrladddropTsClientModeTablenot-accessiblecurrentList of pm1004vencCtrladddropTsClientMode Article
1.3.6.1.4.1.20044.43.6.2.136.1Rowpm1004vencCtrladddropTsClientModeEntrynot-accessiblecurrentRow definition for the pm1004vencCtrladddropTsClientMode table
1.3.6.1.4.1.20044.43.6.2.136.1.1Columnpm1004vencCtrladddropTsClientModeIndexread-onlycurrentIndex definition for the pm1004vencCtrladddropTsClientMode table
1.3.6.1.4.1.20044.43.6.2.136.1.2Columnpm1004vencCtrladddropTsClientModePortnread-writecurrentClient Mode :This OID selects the mode on the client <Help> This control defines the mode (Add/Drop or Split&Select) of the Client
1.3.6.1.4.1.20044.43.6.3Nodepm1004vencCtrlLine
1.3.6.1.4.1.20044.43.6.3.64Nodepm1004vencCtrlcommAccessLoop
1.3.6.1.4.1.20044.43.6.3.64.1Scalarpm1004vencCtrlCommAccessloopread-writedeprecatedPM Full Access Loop Mode :This OID, when set, puts the module in common access loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.
1.3.6.1.4.1.20044.43.6.3.66Nodepm1004vencCtrllineLoop
1.3.6.1.4.1.20044.43.6.3.66.1Scalarpm1004vencCtrlLineLoopread-writedeprecatedPM Line Loop Mode :This OID, when set at '1' puts the module in line loopback mode, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. The Ups…
1.3.6.1.4.1.20044.43.6.3.73Nodepm1004vencCtrlProtMgnt
1.3.6.1.4.1.20044.43.6.3.73.1Scalarpm1004vencCtrlLineNumberread-writecurrentActive Line Number : This OID sets the active line number
1.3.6.1.4.1.20044.43.6.3.73.2Scalarpm1004vencCtrlProtModeread-writecurrentLine Switch Mode (Auto Or Manual) :This bit selects the manual (1) or automatic (0) switch method <Help> This control defines the protection switch mode on the…
1.3.6.1.4.1.20044.43.6.3.74Tablepm1004vencCtrllineOosModeTablenot-accessiblecurrentList of pm1004vencCtrllineOosMode Article
1.3.6.1.4.1.20044.43.6.3.74.1Rowpm1004vencCtrllineOosModeEntrynot-accessiblecurrentRow definition for the pm1004vencCtrllineOosMode table
1.3.6.1.4.1.20044.43.6.3.74.1.1Columnpm1004vencCtrllineOosModeIndexread-onlycurrentIndex definition for the pm1004vencCtrllineOosMode table
1.3.6.1.4.1.20044.43.6.3.74.1.2Columnpm1004vencCtrllineOosModePortnread-writecurrentLine Out Of Service (!Laser OFF!) :This OID sets the line port Out Of Service <Help> This control defines the service state of the line port
1.3.6.1.4.1.20044.43.6.3.198Tablepm1004vencCtrldccEnableTablenot-accessiblecurrentList of pm1004vencCtrldccEnable Article
1.3.6.1.4.1.20044.43.6.3.198.1Rowpm1004vencCtrldccEnableEntrynot-accessiblecurrentRow definition for the pm1004vencCtrldccEnable table
1.3.6.1.4.1.20044.43.6.3.198.1.1Columnpm1004vencCtrldccEnableIndexread-onlycurrentIndex definition for the pm1004vencCtrldccEnable table
1.3.6.1.4.1.20044.43.6.3.198.1.2Columnpm1004vencCtrldccEnablePortnread-writecurrentDCC Enable : This OID enables the DCC mode on the PM <Help> This control enables the DCC mode on the PM
1.3.6.1.4.1.20044.43.6.3.208Tablepm1004vencCtrlxfpOnoffTablenot-accessiblecurrentList of pm1004vencCtrlxfpOnoff Article
1.3.6.1.4.1.20044.43.6.3.208.1Rowpm1004vencCtrlxfpOnoffEntrynot-accessiblecurrentRow definition for the pm1004vencCtrlxfpOnoff table
1.3.6.1.4.1.20044.43.6.3.208.1.1Columnpm1004vencCtrlxfpOnoffIndexread-onlycurrentIndex definition for the pm1004vencCtrlxfpOnoff table
1.3.6.1.4.1.20044.43.6.3.208.1.2Columnpm1004vencCtrlxfpOnoffPortnread-writecurrentLine Optical Laser Shutdown :This OID switches off the XFP or the OTX <Help> This control defines the laser state of the line transceiver
1.3.6.1.4.1.20044.43.6.3.209Tablepm1004vencCtrlxfpLineLoopTablenot-accessiblecurrentList of pm1004vencCtrlxfpLineLoop Article
1.3.6.1.4.1.20044.43.6.3.209.1Rowpm1004vencCtrlxfpLineLoopEntrynot-accessiblecurrentRow definition for the pm1004vencCtrlxfpLineLoop table
1.3.6.1.4.1.20044.43.6.3.209.1.1Columnpm1004vencCtrlxfpLineLoopIndexread-onlycurrentIndex definition for the pm1004vencCtrlxfpLineLoop table
1.3.6.1.4.1.20044.43.6.3.209.1.2Columnpm1004vencCtrlxfpLineLoopPortnread-writecurrentLine Facility Loopback :This OID operates a Line Facility Loopback, looping line input signal on the line output port. The loop is located on the line transcei…
1.3.6.1.4.1.20044.43.6.3.210Tablepm1004vencCtrlxfpXfiLoopTablenot-accessiblecurrentList of pm1004vencCtrlxfpXfiLoop Article
1.3.6.1.4.1.20044.43.6.3.210.1Rowpm1004vencCtrlxfpXfiLoopEntrynot-accessiblecurrentRow definition for the pm1004vencCtrlxfpXfiLoop table
1.3.6.1.4.1.20044.43.6.3.210.1.1Columnpm1004vencCtrlxfpXfiLoopIndexread-onlycurrentIndex definition for the pm1004vencCtrlxfpXfiLoop table
1.3.6.1.4.1.20044.43.6.3.210.1.2Columnpm1004vencCtrlxfpXfiLoopPortnread-writecurrentLine Terminal Loopback :This OID operates a Line Terminal Loopback, looping line input signal on the line output port. The loop is located on all client transc…
1.3.6.1.4.1.20044.43.6.3.212Tablepm1004vencCtrllineTunableChannelTablenot-accessiblecurrentList of pm1004vencCtrllineTunableChannel Article
1.3.6.1.4.1.20044.43.6.3.212.1Rowpm1004vencCtrllineTunableChannelEntrynot-accessiblecurrentRow definition for the pm1004vencCtrllineTunableChannel table
1.3.6.1.4.1.20044.43.6.3.212.1.1Columnpm1004vencCtrllineTunableChannelIndexread-onlycurrentIndex definition for the pm1004vencCtrllineTunableChannel table
1.3.6.1.4.1.20044.43.6.3.212.1.2Columnpm1004vencCtrllineTunableChannelPortnread-writecurrentITU Channel :This OID selects the ITU channel of the Line OTX TLH Laser <Help> This control defines the ITU channel of the Line OTX TLH Laser
1.3.6.1.4.1.20044.43.6.3.213Tablepm1004vencCtrllinePhotodiodeModeTablenot-accessiblecurrentList of pm1004vencCtrllinePhotodiodeMode Article
1.3.6.1.4.1.20044.43.6.3.213.1Rowpm1004vencCtrllinePhotodiodeModeEntrynot-accessiblecurrentRow definition for the pm1004vencCtrllinePhotodiodeMode table
1.3.6.1.4.1.20044.43.6.3.213.1.1Columnpm1004vencCtrllinePhotodiodeModeIndexread-onlycurrentIndex definition for the pm1004vencCtrllinePhotodiodeMode table
1.3.6.1.4.1.20044.43.6.3.213.1.2Columnpm1004vencCtrllinePhotodiodeModePortnread-writecurrentOTX TLH Rx Sens. Mode :This OID defines the Rx sensiblity mode of the Line OTX TLH <Help> This control defines the receiver sensibility mode of the Line OTX TL…
1.3.6.1.4.1.20044.43.6.3.214Tablepm1004vencCtrllinePhotodiodeValueTablenot-accessiblecurrentList of pm1004vencCtrllinePhotodiodeValue Article
1.3.6.1.4.1.20044.43.6.3.214.1Rowpm1004vencCtrllinePhotodiodeValueEntrynot-accessiblecurrentRow definition for the pm1004vencCtrllinePhotodiodeValue table
1.3.6.1.4.1.20044.43.6.3.214.1.1Columnpm1004vencCtrllinePhotodiodeValueIndexread-onlycurrentIndex definition for the pm1004vencCtrllinePhotodiodeValue table
1.3.6.1.4.1.20044.43.6.3.214.1.2Columnpm1004vencCtrllinePhotodiodeValuePortnread-writecurrentOTX TLH Rx Sensibility :This OID sets the Rx sensibility of the Line OTX TLH (custom mode only) <Help> This control defines the receiver sensibility value (onl…
1.3.6.1.4.1.20044.43.6.3.215Tablepm1004vencCtrllinePowerLaserTablenot-accessiblecurrentList of pm1004vencCtrllinePowerLaser Article
1.3.6.1.4.1.20044.43.6.3.215.1Rowpm1004vencCtrllinePowerLaserEntrynot-accessiblecurrentRow definition for the pm1004vencCtrllinePowerLaser table
1.3.6.1.4.1.20044.43.6.3.215.1.1Columnpm1004vencCtrllinePowerLaserIndexread-onlycurrentIndex definition for the pm1004vencCtrllinePowerLaser table
1.3.6.1.4.1.20044.43.6.3.215.1.2Columnpm1004vencCtrllinePowerLaserPortnread-writecurrentLine Laser Output Power [3-5] :This OID sets the output power value on the laser of the Line OTX TLH (AV=Power*10+158) (Unit = dBm) <Help> This control defines…
1.3.6.1.4.1.20044.43.7Nodepm1004vencri
1.3.6.1.4.1.20044.43.7.1Nodepm1004vencriTable
1.3.6.1.4.1.20044.43.7.1.1Tablepm1004vencRinvClientTablenot-accessiblecurrentList of the video clients on the selected module
1.3.6.1.4.1.20044.43.7.1.1.1Rowpm1004vencRinvClientEntrynot-accessiblecurrentRow definition for the video client table
1.3.6.1.4.1.20044.43.7.1.1.1.1Columnpm1004vencRinvClientIndexread-onlycurrentIndex for video client table
1.3.6.1.4.1.20044.43.7.1.1.1.2Columnpm1004vencRinvClientread-onlycurrentInventory for the video client: This OID contains the inventory for the video client
1.3.6.1.4.1.20044.43.7.1.2Tablepm1004vencRinvLineTablenot-accessiblecurrentList of the XFPs on the selected module
1.3.6.1.4.1.20044.43.7.1.2.1Rowpm1004vencRinvLineEntrynot-accessiblecurrentRow definition for the XFP table
1.3.6.1.4.1.20044.43.7.1.2.1.1Columnpm1004vencRinvLineIndexread-onlycurrentIndex for XFP table
1.3.6.1.4.1.20044.43.7.1.2.1.2Columnpm1004vencRinvxfpLineread-onlycurrentInventory for the XFP: This OID contains the inventory for the XFP
1.3.6.1.4.1.20044.43.7.2Scalarpm1004vencRinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.43.7.3Scalarpm1004vencRinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.43.7.4Scalarpm1004vencRinvModulePlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.43.7.5Scalarpm1004vencRinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.43.7.6Scalarpm1004vencRinvGwPlatformread-onlycurrentGW platform desciption: This OID contains the description of the Gateware platform.
1.3.6.1.4.1.20044.43.8Nodepm1004vencdownload
1.3.6.1.4.1.20044.43.8.1Nodepm1004vencDwlOther
1.3.6.1.4.1.20044.43.8.1.0Nodepm1004vencDwlrestartProcess
1.3.6.1.4.1.20044.43.8.1.0.1Scalarpm1004vencDwlWarmRestartProcessedread-onlycurrentWarm Restart :This OID indicates that the module last restart was a Warm RESTART
1.3.6.1.4.1.20044.43.8.1.0.2Scalarpm1004vencDwlColdRestartProcessedread-onlycurrentCold Restart :This OID indicates that the module last restart was a Cold RESTART
1.3.6.1.4.1.20044.43.8.1.1Nodepm1004vencDwlswBanksUsed
1.3.6.1.4.1.20044.43.8.1.1.1Scalarpm1004vencDwlSwBank1Usedread-onlycurrentSW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby
1.3.6.1.4.1.20044.43.8.1.1.2Scalarpm1004vencDwlSwBank2Usedread-onlycurrentSW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby
1.3.6.1.4.1.20044.43.8.1.1.5Scalarpm1004vencDwlSwBank1Notemptyread-onlycurrentSW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package
1.3.6.1.4.1.20044.43.8.1.1.6Scalarpm1004vencDwlSwBank2Notemptyread-onlycurrentSW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package
1.3.6.1.4.1.20044.43.8.1.2Nodepm1004vencDwlgwBanksUsed
1.3.6.1.4.1.20044.43.8.1.2.1Scalarpm1004vencDwlGwBank1Usedread-onlycurrentGW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby
1.3.6.1.4.1.20044.43.8.1.2.2Scalarpm1004vencDwlGwBank2Usedread-onlycurrentGW bank 2 active :This OID indicates the module is working on GW bank 2
1.3.6.1.4.1.20044.43.8.1.2.3Scalarpm1004vencDwlGwBank3Usedread-onlycurrentGW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby
1.3.6.1.4.1.20044.43.8.1.2.4Scalarpm1004vencDwlGwBank4Usedread-onlycurrentGW bank 4 active :This OID indicates the module is working on GW bank 4
1.3.6.1.4.1.20044.43.8.1.2.5Scalarpm1004vencDwlGwBank1Notemptyread-onlycurrentGW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package
1.3.6.1.4.1.20044.43.8.1.2.6Scalarpm1004vencDwlGwBank2Notemptyread-onlycurrentGW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2
1.3.6.1.4.1.20044.43.8.1.2.7Scalarpm1004vencDwlGwBank3Notemptyread-onlycurrentGW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package
1.3.6.1.4.1.20044.43.8.1.2.8Scalarpm1004vencDwlGwBank4Notemptyread-onlycurrentGW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4
1.3.6.1.4.1.20044.43.8.2Nodepm1004vencDwlClient
1.3.6.1.4.1.20044.43.8.3Nodepm1004vencDwlLine
1.3.6.1.4.1.20044.43.9Nodepm1004vencConfig
1.3.6.1.4.1.20044.43.9.1Nodepm1004vencCfgAccessCAisCsf
1.3.6.1.4.1.20044.43.9.1.1Tablepm1004vencCfgClientcaiscsfTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.43.9.1.1.1Rowpm1004vencCfgClientcaiscsfEntrynot-accessiblecurrentRow definition for the accessCAisCsf table
1.3.6.1.4.1.20044.43.9.1.1.1.1Columnpm1004vencCfgClientcaiscsfIndexread-onlycurrentIndex definition for the clientcaiscsf table
1.3.6.1.4.1.20044.43.9.1.1.1.3Columnpm1004vencCfgCAisModePortnread-writecurrentCAIS mode on Client Port :This register enables/disables port laser shutdown on CAIS insertion condition
1.3.6.1.4.1.20044.43.9.1.1.1.9Columnpm1004vencCfgUpAccessioAlmPortnread-writecurrentCSF contributors on Client Port :This register configures the contributors to upstream CSF insertion on the port.
1.3.6.1.4.1.20044.43.9.1.1.1.10Columnpm1004vencCfgUpMapperDeAlmPortnread-writecurrentCSF contributors on Client Port :This register configures the contributors to upstream CSF insertion on the port.
1.3.6.1.4.1.20044.43.9.1.1.1.17Columnpm1004vencCfgDownAccessioAlmPortnread-writecurrentCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port.
1.3.6.1.4.1.20044.43.9.1.1.1.18Columnpm1004vencCfgDownMapperDeAlmPortnread-writecurrentCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port.
1.3.6.1.4.1.20044.43.9.1.1.1.19Columnpm1004vencCfgDownDfrmAlmPortnread-writecurrentCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port.
1.3.6.1.4.1.20044.43.9.1.1.1.20Columnpm1004vencCfgDownLineSyncAlarmsPortnread-writedeprecatedCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port.
1.3.6.1.4.1.20044.43.9.2Nodepm1004vencCfgStartup
1.3.6.1.4.1.20044.43.9.2.1Tablepm1004vencCfgClientStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.43.9.2.1.1Rowpm1004vencCfgClientStartupEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.43.9.2.1.1.1Columnpm1004vencCfgClientStartupIndexread-onlycurrentIndex definition for the clientStartup table
1.3.6.1.4.1.20044.43.9.2.1.1.3Columnpm1004vencCfgSystConfPortPortnread-writecurrentDefault Settings on Client Port :This register configures the default initialisation settings on the port.
1.3.6.1.4.1.20044.43.9.2.1.1.4Columnpm1004vencCfgNetConfPortPortnread-writecurrentDefault Protocol on Client Port :This register configures the default initialisation protocol on the port.
1.3.6.1.4.1.20044.43.9.2.1.1.5Columnpm1004vencCfgAdddropConfPortPortnread-writedeprecatedDefault Add&Drop mode on Client Port :This register configures the default Add&Drop mode on the port.
1.3.6.1.4.1.20044.43.9.2.2Nodepm1004venctablelineStartup
1.3.6.1.4.1.20044.43.9.2.2.2Scalarpm1004vencCfgsystConfLine1read-writecurrentDefault Settings on Line 1 :This register configures the default initialisation settings on Line port 1.
1.3.6.1.4.1.20044.43.9.2.2.5Scalarpm1004vencCfglineOptions1read-writecurrentDefault Options on Active Line Port :This register configures the default options on the active line port
1.3.6.1.4.1.20044.43.9.2.2.6Scalarpm1004vencCfgsystConfLine2read-writecurrentDefault Settings on Line 2 :This register configures the default initialisation settings on Line port 2.
1.3.6.1.4.1.20044.43.9.2.2.7Scalarpm1004vencCfglineSelectionread-writecurrentDefault Settings of active line :This register configures the start up active line.
1.3.6.1.4.1.20044.43.9.2.2.9Scalarpm1004vencCfglineOptions2read-writecurrentDefault Options on Active Line Port :This register configures the default options on the active line port
1.3.6.1.4.1.20044.43.9.2.3Tablepm1004vencCfgXfpTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.43.9.2.3.1Rowpm1004vencCfgXfpEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.43.9.2.3.1.1Columnpm1004vencCfgXfpIndexread-onlycurrentIndex definition for the xfp table
1.3.6.1.4.1.20044.43.9.2.3.1.3Columnpm1004vencCfgSystConfXfpPortnread-writecurrentDefault settings on XFP Port :This register configures the default initialisation settings on XFP port.
1.3.6.1.4.1.20044.43.9.2.3.1.4Columnpm1004vencCfgDataRateConfXfpPortnread-writedeprecated:
1.3.6.1.4.1.20044.43.9.3Nodepm1004vencCfgLabels
1.3.6.1.4.1.20044.43.9.3.1Tablepm1004vencCfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.43.9.3.1.1Rowpm1004vencCfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.43.9.3.1.1.1Columnpm1004vencCfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.43.9.3.1.1.3Columnpm1004vencCfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.43.9.3.2Tablepm1004vencCfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.43.9.3.2.1Rowpm1004vencCfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.43.9.3.2.1.1Columnpm1004vencCfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.43.9.3.2.1.3Columnpm1004vencCfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.43.9.4Nodepm1004vencCfgStartupthresholds
1.3.6.1.4.1.20044.43.9.4.1Tablepm1004vencCfgClientStartupThreshTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.43.9.4.1.1Rowpm1004vencCfgClientStartupThreshEntrynot-accessiblecurrentRow definition for the startupthresholds table
1.3.6.1.4.1.20044.43.9.4.1.1.1Columnpm1004vencCfgClientStartupThreshIndexread-onlycurrentIndex definition for the clientStartupThresh table
1.3.6.1.4.1.20044.43.9.4.1.1.15Columnpm1004vencCfgClientThreshtxpowhighPortnread-writecurrentDefault Setting on Tx Power high threshold :This register configures the default initialisation of the high threshold of the Transmit power on the port.
1.3.6.1.4.1.20044.43.9.4.1.1.16Columnpm1004vencCfgClientThreshtxpowlowPortnread-writecurrentDefault Setting on Tx Power low threshold :This register configures the default initialisation of the low threshold of the Transmit power on the port.
1.3.6.1.4.1.20044.43.9.4.1.1.19Columnpm1004vencCfgClientThreshrxpowhighPortnread-writecurrentDefault Setting on Rx Power high threshold :This register configures the default initialisation of the high threshold of the received power on the port.
1.3.6.1.4.1.20044.43.9.4.1.1.20Columnpm1004vencCfgClientThreshrxpowlowPortnread-writecurrentDefault Setting on Rx Power low threshold :This register configures the default initialisation of the low threshold of the received power on the port.
1.3.6.1.4.1.20044.43.9.4.2Tablepm1004vencCfgLineStartupThreshTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.43.9.4.2.1Rowpm1004vencCfgLineStartupThreshEntrynot-accessiblecurrentRow definition for the startupthresholds table
1.3.6.1.4.1.20044.43.9.4.2.1.1Columnpm1004vencCfgLineStartupThreshIndexread-onlycurrentIndex definition for the lineStartupThresh table
1.3.6.1.4.1.20044.43.9.4.2.1.15Columnpm1004vencCfgLineThreshtxpowhighPortnread-writecurrentDefault Setting on Tx Power high threshold :This register configures the default initialisation of the high threshold of the Transmit power on the line.
1.3.6.1.4.1.20044.43.9.4.2.1.16Columnpm1004vencCfgLineThreshtxpowlowPortnread-writecurrentDefault Setting on Tx Power low threshold :This register configures the default initialisation of the low threshold of the Transmit power on the line.
1.3.6.1.4.1.20044.43.9.4.2.1.19Columnpm1004vencCfgLineThreshrxpowhighPortnread-writecurrentDefault Setting on Rx Power high threshold :This register configures the default initialisation of the high threshold of the received power on the line.
1.3.6.1.4.1.20044.43.9.4.2.1.20Columnpm1004vencCfgLineThreshrxpowlowPortnread-writecurrentDefault Setting on Rx Power low threshold :This register configures the default initialisation of the low threshold of the received power on the line.
1.3.6.1.4.1.20044.43.9.5Nodepm1004vencCfgOther
1.3.6.1.4.1.20044.43.9.5.1Nodepm1004venctablemoduleOther
1.3.6.1.4.1.20044.43.9.5.1.2Scalarpm1004vencCfgmoderead-writecurrentDefault encryption mode on Module :This register selects the encryption configuration of the PM
1.3.6.1.4.1.20044.43.9.6Nodepm1004vencCfgStartuptlh
1.3.6.1.4.1.20044.43.9.6.1Tablepm1004vencCfgOtxtlhTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.43.9.6.1.1Rowpm1004vencCfgOtxtlhEntrynot-accessiblecurrentRow definition for the startuptlh table
1.3.6.1.4.1.20044.43.9.6.1.1.1Columnpm1004vencCfgOtxtlhIndexread-onlycurrentIndex definition for the otxtlh table
1.3.6.1.4.1.20044.43.9.6.1.1.3Columnpm1004vencCfgNuPortnread-writedeprecated:
1.3.6.1.4.1.20044.43.9.6.1.1.4Columnpm1004vencCfgLineDitherRatePortnread-writecurrentDefault Line OTX TLH FM amplitude :This register configures the start-up width of the frequency modulation of the Line OTX TLH
1.3.6.1.4.1.20044.43.9.6.1.1.5Columnpm1004vencCfgLineDitherFhzPortnread-writecurrentDefault Line OTX TLH FM frequency :This register configures the start-up frequency of the frequency modulation of the Line OTX TLH
1.3.6.1.4.1.20044.43.9.6.1.1.6Columnpm1004vencCfgLinePwrLaserPortnread-writecurrentDefaut Line OTX TLH output Power :This register configures the start-up output power of the Line OTX TLH (Unit = dBm)
1.3.6.1.4.1.20044.43.9.6.1.1.7Columnpm1004vencCfgLineFCurrentPortnread-writecurrentDefault Line OTX TLH Channel :This register configures the start-up laser channel of the Line OTX TLH
1.3.6.1.4.1.20044.43.9.6.1.1.8Columnpm1004vencCfgLineGridCurrentPortnread-writecurrentDefault Line OTX TLH Grid :This register configures the start-up laser grid of the Line OTX TLH
1.3.6.1.4.1.20044.43.9.6.1.1.9Columnpm1004vencCfgFPortnread-writecurrentDefault Line OTX TLH lowest Freq :This register configures the start-up lowest frequency supported on the Line OTX TLH
1.3.6.1.4.1.20044.43.9.6.1.1.10Columnpm1004vencCfgReservedPortnread-writedeprecated:
1.3.6.1.4.1.20044.43.9.6.1.1.11Columnpm1004vencCfgLinePhotodiodeModePortnread-writecurrentDefault Line OTX TLH APD mode :This register configures the start-up APD mode of the Line OTX TLH
1.3.6.1.4.1.20044.43.9.6.1.1.12Columnpm1004vencCfgLinePhotodiodeValuePortnread-writecurrentDefault Line OTX TLH APD atten. :This register configures the start-up APD attenuation on the Line OTX TLH
1.3.6.1.4.1.20044.43.9.7Nodepm1004vencCfgStartuptablefive
1.3.6.1.4.1.20044.43.9.7.1Tablepm1004vencCfgOtxtlhcapabilitiesTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.43.9.7.1.1Rowpm1004vencCfgOtxtlhcapabilitiesEntrynot-accessiblecurrentRow definition for the startuptablefive table
1.3.6.1.4.1.20044.43.9.7.1.1.1Columnpm1004vencCfgOtxtlhcapabilitiesIndexread-onlycurrentIndex definition for the otxtlhcapabilities table
1.3.6.1.4.1.20044.43.9.7.1.1.3Columnpm1004vencCfgComponentTypePortnread-onlycurrentComponent parameters :This OID defines the component parameters
1.3.6.1.4.1.20044.43.9.7.1.1.4Columnpm1004vencCfgMiscellaneousPortnread-onlycurrentMiscellaneous default settings :This OID defines the miscellaneous parameters
1.3.6.1.4.1.20044.43.9.7.1.1.5Columnpm1004vencCfgFirstChannelPortnread-onlycurrentNumber of the first channel of the component :This OID defines the first channel number of the PM
1.3.6.1.4.1.20044.43.9.7.1.1.6Columnpm1004vencCfgLastChannelPortnread-onlycurrentNumber of the last channel of the component :This OID defines the last channel number of the PM
1.3.6.1.4.1.20044.43.9.7.1.1.7Columnpm1004vencCfgGridPortnread-onlycurrentGrid value of the component :This OID defines the grid of the PM
1.3.6.1.4.1.20044.43.9.257Scalarpm1004vencCfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.43.10Nodepm1004venctraps
1.3.6.1.4.1.20044.43.10.2Scalarpm1004venctrapPortNumberread-onlycurrentLast port which generates a trap
1.3.6.1.4.1.20044.43.10.3Scalarpm1004venctrapLineNumberread-onlycurrentLast Line which generates a trap
1.3.6.1.4.1.20044.43.10.4Scalarpm1004venctrapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.43.10.30Notificationpm1004vencLineTrapNotUrgentGoesOncurrentNot urgent Line default is activated
1.3.6.1.4.1.20044.43.10.31Notificationpm1004vencLineTrapNotUrgentGoesOffcurrentNot urgent Line default disappeared
1.3.6.1.4.1.20044.43.10.32Notificationpm1004vencLineTrapUrgentGoesOncurrentUrgent Line default is activated
1.3.6.1.4.1.20044.43.10.33Notificationpm1004vencLineTrapUrgentGoesOffcurrentUrgent Line default disappeared
1.3.6.1.4.1.20044.43.10.34Notificationpm1004vencLineTrapCritGoesOncurrentCritical Line default is activated
1.3.6.1.4.1.20044.43.10.35Notificationpm1004vencLineTrapCritGoesOffcurrentCritical Line default disappeared
1.3.6.1.4.1.20044.43.10.44Notificationpm1004vencClientTrapCritGoesOncurrentCritical client default is activated
1.3.6.1.4.1.20044.43.10.45Notificationpm1004vencClientTrapCritGoesOffcurrentCritical client default disappeared
1.3.6.1.4.1.20044.43.10.50Notificationpm1004vencPowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.43.10.51Notificationpm1004vencPowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared
1.3.6.1.4.1.20044.43.11Nodepm1004vencMonitoring
1.3.6.1.4.1.20044.43.11.1Nodepm1004vencMonOther
1.3.6.1.4.1.20044.43.11.1.3Nodepm1004vencMonRmon
1.3.6.1.4.1.20044.43.11.1.3.359Scalarpm1004vencMonCountersResetread-writecurrentRMON Counters Reset:This OID resets and restarts all the RMON counters
1.3.6.1.4.1.20044.43.11.1.3.360Scalarpm1004vencMonCountersStopread-writecurrentRMON Counters stop:This OID stops all the RMON counters
1.3.6.1.4.1.20044.43.11.2Nodepm1004vencMonClient
1.3.6.1.4.1.20044.43.11.2.4Nodepm1004vencMonClientRmonCounter
1.3.6.1.4.1.20044.43.11.2.4.16Tablepm1004vencMonupRmonByteCntTablenot-accessiblecurrentList of pm1004vencMonupRmonByteCnt Article
1.3.6.1.4.1.20044.43.11.2.4.16.1Rowpm1004vencMonupRmonByteCntEntrynot-accessiblecurrentRow definition for the pm1004vencMonupRmonByteCnt table
1.3.6.1.4.1.20044.43.11.2.4.16.1.1Columnpm1004vencMonupRmonByteCntIndexread-onlycurrentIndex definition for the pm1004vencMonupRmonByteCnt table
1.3.6.1.4.1.20044.43.11.2.4.16.1.2Columnpm1004vencMonupRmonByteCntValuePortnread-onlycurrentClient Input Bytes :This counter is increased each time a data byte is received on the client port <Help> This counter gives the number of bytes received on th…
1.3.6.1.4.1.20044.43.11.2.4.16.1.3Columnpm1004vencMonupRmonByteCntErrorPortnread-onlycurrentBytes Counter Error :This OID when set indicates the Bytes counter value is invalid on clinet port
1.3.6.1.4.1.20044.43.11.2.4.16.1.4Columnpm1004vencMonupRmonByteCntOverloadPortnread-onlycurrentBytes Counter Overload :This OID when set indicates a Bytes counter overload on client port
1.3.6.1.4.1.20044.43.11.2.4.24Tablepm1004vencMonupRmonCrcErrorCntTablenot-accessiblecurrentList of pm1004vencMonupRmonCrcErrorCnt Article
1.3.6.1.4.1.20044.43.11.2.4.24.1Rowpm1004vencMonupRmonCrcErrorCntEntrynot-accessiblecurrentRow definition for the pm1004vencMonupRmonCrcErrorCnt table
1.3.6.1.4.1.20044.43.11.2.4.24.1.1Columnpm1004vencMonupRmonCrcErrorCntIndexread-onlycurrentIndex definition for the pm1004vencMonupRmonCrcErrorCnt table
1.3.6.1.4.1.20044.43.11.2.4.24.1.2Columnpm1004vencMonupRmonCrcErrorCntValuePortnread-onlycurrentClient Input CRC Errors :This counter is increased each time a CRC error is detected on the client port <Help> This counter gives the number of CRC Errors rece…
1.3.6.1.4.1.20044.43.11.2.4.24.1.3Columnpm1004vencMonupRmonCrcErrorCntErrorPortnread-onlycurrentCRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on clinet port
1.3.6.1.4.1.20044.43.11.2.4.24.1.4Columnpm1004vencMonupRmonCrcErrorCntOverloadPortnread-onlycurrentCRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on client port
1.3.6.1.4.1.20044.43.11.2.4.32Tablepm1004vencMonupRmonPacketsCntTablenot-accessiblecurrentList of pm1004vencMonupRmonPacketsCnt Article
1.3.6.1.4.1.20044.43.11.2.4.32.1Rowpm1004vencMonupRmonPacketsCntEntrynot-accessiblecurrentRow definition for the pm1004vencMonupRmonPacketsCnt table
1.3.6.1.4.1.20044.43.11.2.4.32.1.1Columnpm1004vencMonupRmonPacketsCntIndexread-onlycurrentIndex definition for the pm1004vencMonupRmonPacketsCnt table
1.3.6.1.4.1.20044.43.11.2.4.32.1.2Columnpm1004vencMonupRmonPacketsCntValuePortnread-onlycurrentClient Input Packets :This counter is increased each time a packet is received on the client port <Help> This counter gives the number of packets received on t…
1.3.6.1.4.1.20044.43.11.2.4.32.1.3Columnpm1004vencMonupRmonPacketsCntErrorPortnread-onlycurrentPackets Counter Error :This OID when set indicates the Packets counter value is invalid on clinet port
1.3.6.1.4.1.20044.43.11.2.4.32.1.4Columnpm1004vencMonupRmonPacketsCntOverloadPortnread-onlycurrentPackets Counter Overload :This OID when set indicates a Packets counter overload on client port
1.3.6.1.4.1.20044.43.11.2.4.40Tablepm1004vencMonupRmonBroadcastCntTablenot-accessiblecurrentList of pm1004vencMonupRmonBroadcastCnt Article
1.3.6.1.4.1.20044.43.11.2.4.40.1Rowpm1004vencMonupRmonBroadcastCntEntrynot-accessiblecurrentRow definition for the pm1004vencMonupRmonBroadcastCnt table
1.3.6.1.4.1.20044.43.11.2.4.40.1.1Columnpm1004vencMonupRmonBroadcastCntIndexread-onlycurrentIndex definition for the pm1004vencMonupRmonBroadcastCnt table
1.3.6.1.4.1.20044.43.11.2.4.40.1.2Columnpm1004vencMonupRmonBroadcastCntValuePortnread-onlycurrentClient Input Broadcast Packets :This counter is increased each time a broadcast packet is received on the client port <Help> This counter gives the number of B…
1.3.6.1.4.1.20044.43.11.2.4.40.1.3Columnpm1004vencMonupRmonBroadcastCntErrorPortnread-onlycurrentBroadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on clinet port
1.3.6.1.4.1.20044.43.11.2.4.40.1.4Columnpm1004vencMonupRmonBroadcastCntOverloadPortnread-onlycurrentBroadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port
1.3.6.1.4.1.20044.43.11.2.4.48Tablepm1004vencMonupRmonMulticastCntTablenot-accessiblecurrentList of pm1004vencMonupRmonMulticastCnt Article
1.3.6.1.4.1.20044.43.11.2.4.48.1Rowpm1004vencMonupRmonMulticastCntEntrynot-accessiblecurrentRow definition for the pm1004vencMonupRmonMulticastCnt table
1.3.6.1.4.1.20044.43.11.2.4.48.1.1Columnpm1004vencMonupRmonMulticastCntIndexread-onlycurrentIndex definition for the pm1004vencMonupRmonMulticastCnt table
1.3.6.1.4.1.20044.43.11.2.4.48.1.2Columnpm1004vencMonupRmonMulticastCntValuePortnread-onlycurrentClient Input Multicast Packets :This counter is increased each time a Multicast packet is received on the client port <Help> This counter gives the number of M…
1.3.6.1.4.1.20044.43.11.2.4.48.1.3Columnpm1004vencMonupRmonMulticastCntErrorPortnread-onlycurrentMulticast Counter Error :This OID when set indicates the Multicast counter value is invalid on clinet port
1.3.6.1.4.1.20044.43.11.2.4.48.1.4Columnpm1004vencMonupRmonMulticastCntOverloadPortnread-onlycurrentMulticast Counter Overload :This OID when set indicates a Multicast counter overload on client port
1.3.6.1.4.1.20044.43.11.2.4.208Tablepm1004vencMonupLineRmonByteCntTablenot-accessiblecurrentList of pm1004vencMonupLineRmonByteCnt Article
1.3.6.1.4.1.20044.43.11.2.4.208.1Rowpm1004vencMonupLineRmonByteCntEntrynot-accessiblecurrentRow definition for the pm1004vencMonupLineRmonByteCnt table
1.3.6.1.4.1.20044.43.11.2.4.208.1.1Columnpm1004vencMonupLineRmonByteCntIndexread-onlycurrentIndex definition for the pm1004vencMonupLineRmonByteCnt table
1.3.6.1.4.1.20044.43.11.2.4.208.1.2Columnpm1004vencMonupLineRmonByteCntValuePortnread-onlycurrentLine Input Bytes :This counter is increased each time a data byte is received on the Line port <Help> This counter gives the number of bytes received on the Li…
1.3.6.1.4.1.20044.43.11.2.4.208.1.3Columnpm1004vencMonupLineRmonByteCntErrorPortnread-onlycurrentBytes Counter Error :This OID when set indicates the Bytes counter value is invalid on line port
1.3.6.1.4.1.20044.43.11.2.4.208.1.4Columnpm1004vencMonupLineRmonByteCntOverloadPortnread-onlycurrentBytes Counter Overload :This OID when set indicates a Bytes counter overload on line port
1.3.6.1.4.1.20044.43.11.2.4.209Tablepm1004vencMonupLineRmonCrcErrorCntTablenot-accessiblecurrentList of pm1004vencMonupLineRmonCrcErrorCnt Article
1.3.6.1.4.1.20044.43.11.2.4.209.1Rowpm1004vencMonupLineRmonCrcErrorCntEntrynot-accessiblecurrentRow definition for the pm1004vencMonupLineRmonCrcErrorCnt table
1.3.6.1.4.1.20044.43.11.2.4.209.1.1Columnpm1004vencMonupLineRmonCrcErrorCntIndexread-onlycurrentIndex definition for the pm1004vencMonupLineRmonCrcErrorCnt table
1.3.6.1.4.1.20044.43.11.2.4.209.1.2Columnpm1004vencMonupLineRmonCrcErrorCntValuePortnread-onlycurrentLine Input CRC Errors :This counter is increased each time a CRC error is detected on the Line port <Help> This counter gives the number of CRC Errors received…
1.3.6.1.4.1.20044.43.11.2.4.209.1.3Columnpm1004vencMonupLineRmonCrcErrorCntErrorPortnread-onlycurrentCRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on line port
1.3.6.1.4.1.20044.43.11.2.4.209.1.4Columnpm1004vencMonupLineRmonCrcErrorCntOverloadPortnread-onlycurrentCRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on line port
1.3.6.1.4.1.20044.43.11.2.4.210Tablepm1004vencMonupLineRmonPacketsCntTablenot-accessiblecurrentList of pm1004vencMonupLineRmonPacketsCnt Article
1.3.6.1.4.1.20044.43.11.2.4.210.1Rowpm1004vencMonupLineRmonPacketsCntEntrynot-accessiblecurrentRow definition for the pm1004vencMonupLineRmonPacketsCnt table
1.3.6.1.4.1.20044.43.11.2.4.210.1.1Columnpm1004vencMonupLineRmonPacketsCntIndexread-onlycurrentIndex definition for the pm1004vencMonupLineRmonPacketsCnt table
1.3.6.1.4.1.20044.43.11.2.4.210.1.2Columnpm1004vencMonupLineRmonPacketsCntValuePortnread-onlycurrentLine Input Packets :This counter is increased each time a packet is received on the Line port <Help> This counter gives the number of packets received on the L…
1.3.6.1.4.1.20044.43.11.2.4.210.1.3Columnpm1004vencMonupLineRmonPacketsCntErrorPortnread-onlycurrentPackets Counter Error :This OID when set indicates the Packets counter value is invalid on client port
1.3.6.1.4.1.20044.43.11.2.4.210.1.4Columnpm1004vencMonupLineRmonPacketsCntOverloadPortnread-onlycurrentPackets Counter Overload :This OID when set indicates a Packets counter overload on line port
1.3.6.1.4.1.20044.43.11.3Nodepm1004vencMonLine
1.3.6.1.4.1.20044.43.11.3.4Nodepm1004vencMonLineRmonCounter
Type Definitions
NameSyntaxStatusDescription
Pm1004vencAdjustValueINTEGER { otxadjustvalue0(0), otxadjustvalue1(1), otxadjustvalue2(2), otxadjustvalue3(3), otxadjustvalue4(4), otxadjustvalue5(5), otxadjustvalue6(6), otxadjustvalue7(7), otxadjustvalue8(8), otxadjustvalue9(9), otxadjustvalue10(10), }currentDifferent values in Adjust mode on OTX-TLH on line ports
Pm1004vencClientOosModeINTEGER { clientportis(0), clienttxoos(1), clientrxoos(2), clientportoos(3) }currentMode for OOS on client ports
Pm1004vencDccModeINTEGER { dccNo(0), dcctermLine1(1), dcctermLine2(2), dcctermLines12(3), dccmaster(4), dccslaveLine12(7) }currentMode for DCC
Pm1004vencKeyModeINTEGER { key1(0), key2(1) }currentMode for encryption key
Pm1004vencModeAddDropINTEGER { singleSplitSelect(256) }currentdifferent mode for client
Pm1004vencModeTimeSlotINTEGER { singleSplitSelect(256) }currentdifferent mode for time slot
Pm1004vencOtxChannelINTEGER { }currentChannel selection on OTX-TLH on line ports
Pm1004vencOtxGridINTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50), }currentDifferent grids on OTX-TLH on line ports
Pm1004vencOtxModeINTEGER { otx80mode(1), otx60mode(2), otxadjustmode(4), }currentDifferent modes on OTX-TLH on line ports
Pm1004vencProtectionStartUpINTEGER { auto(2), manualX2Line2(0), manualX1Line1(1) }currentprotection for startup
Pm1004vencProtectionTimeSlotINTEGER { auto(0), manualX2Line2(257), manualX1Line1(513) }currentprotection for control