MIB Viewer

EKINOPS-Pm1005-MIB

599 objects
MIB for managing Ekinops modules with PM1005 software
OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.26IdentitymodulePm1005MIB for managing Ekinops modules with PM1005 software
1.3.6.1.4.1.20044.26.2Nodepm1005alarms
1.3.6.1.4.1.20044.26.2.1Nodepm1005AlmOther
1.3.6.1.4.1.20044.26.2.1.1Nodepm1005AlmOtherNurg
1.3.6.1.4.1.20044.26.2.1.1.2Nodepm1005AlmsynthAlm2
1.3.6.1.4.1.20044.26.2.1.1.2.1Scalarpm1005AlmConfTableSaveread-onlycurrentPM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> other…
1.3.6.1.4.1.20044.26.2.1.1.2.2Scalarpm1005AlmInvUploadread-onlycurrentInventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> other (1) <Alarmtype> <Polarity> (2)
1.3.6.1.4.1.20044.26.2.1.1.2.3Scalarpm1005AlmConfTableLoadread-onlycurrentPM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> other (1) <Alarmt…
1.3.6.1.4.1.20044.26.2.1.1.2.4Scalarpm1005AlmCorrelatOffread-onlycurrentNot Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> other (1) <Alarmtype> <Polarity> (2)
1.3.6.1.4.1.20044.26.2.1.1.2.5Scalarpm1005AlmMaintenanceOnread-onlycurrentMaintenance Mode :This OID indicates that the PM is in maintenance mode. <Help> This alarm indicates that the maintenance mode is enabled on the PM <Condtype> …
1.3.6.1.4.1.20044.26.2.1.2Nodepm1005AlmOtherUrg
1.3.6.1.4.1.20044.26.2.1.2.194Nodepm1005AlmmodInitFailLevel2
1.3.6.1.4.1.20044.26.2.1.2.194.1Scalarpm1005AlmLedFailread-onlycurrentLed Fail :This OID indicates that Led register has not been correctly initalized <Help> This alarm indicates if the module LEDs are correctly initialized <Cond…
1.3.6.1.4.1.20044.26.2.1.2.194.2Scalarpm1005AlmNextColdBootForcedread-onlycurrentNext Cold Boot Forced :This OID indicates that the next Reset will be forced Cold <Help> This alarm indicates that the next reset of the module will be forced …
1.3.6.1.4.1.20044.26.2.1.2.194.3Scalarpm1005AlmBootUndoneread-onlycurrentBoot Undone :This OID indicates that the boot has not been correctly achieved <Help> This alarm indicates if the module has correctly boot <Condtype> BOOT_UNDO…
1.3.6.1.4.1.20044.26.2.1.2.194.4Scalarpm1005AlmResetHwInitFailread-onlycurrentReset HW Init Fail :This OID indicates that the HW intialization has caused unknown intial conditions <Help> This alarm indicates if the HW has been correctly …
1.3.6.1.4.1.20044.26.2.1.2.194.5Scalarpm1005AlmSwInitFailread-onlycurrentSW Init Fail :This OID indicates that the SW intialization has caused unknown intial conditions <Help> This alarm indicates if the SW module is correctly initi…
1.3.6.1.4.1.20044.26.2.1.2.195Nodepm1005AlmmodInitFailLevel3
1.3.6.1.4.1.20044.26.2.1.2.195.1Scalarpm1005AlmGwIdentFailread-onlycurrentGW Ident Fail :This OID indicates that GW identification has not been read <Help> This alarm indicates if the GW has been correctly identified <Condtype> GW_ID…
1.3.6.1.4.1.20044.26.2.1.2.195.2Scalarpm1005AlmObmTypeReadFailread-onlycurrentOBM Type Read Fail :This OID indicates that OBM type has not been recognized <Help> This alarm indicates if the OBM board has been correctly identified <Condty…
1.3.6.1.4.1.20044.26.2.1.2.195.3Scalarpm1005AlmInitModuleFailread-onlycurrentInit Module Fail :This OID indicates that the Module has not been correctly initialized <Help> This alarm indicates if the SW module is correctly initialized <…
1.3.6.1.4.1.20044.26.2.1.2.195.5Scalarpm1005AlmXfp1InitFailread-onlycurrentXFP1 Init Fail :This OID indicates that the XFP has not been correctly initialized <Help> This alarm indicates if the line transceiver 1 is correctly initializ…
1.3.6.1.4.1.20044.26.2.1.2.195.6Scalarpm1005AlmXfp2InitFailread-onlycurrentXFP2 Init Fail :This OID indicates that the XFP has not been correctly initialized <Help> This alarm indicates if the line transceiver 2 is correctly initializ…
1.3.6.1.4.1.20044.26.2.1.2.195.7Scalarpm1005AlmLine1InitFailread-onlycurrentLine1 Init Fail :This OID indicates that the Line registersvsubset has not been correctly initialized <Help> This alarm indicates if the line port 1 is correct…
1.3.6.1.4.1.20044.26.2.1.2.195.8Scalarpm1005AlmLine2InitFailread-onlycurrentLine2 Init Fail :This OID indicates that the Line register subset has not been correctly initialized <Help> This alarm indicates if the line port 2 is correctl…
1.3.6.1.4.1.20044.26.2.1.2.195.9Scalarpm1005AlmClient1InitFailread-onlycurrentClient1 Init Fail :This OID indicates that Client 1 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 1 is cor…
1.3.6.1.4.1.20044.26.2.1.2.195.10Scalarpm1005AlmClient2InitFailread-onlycurrentClient2 Init Fail :This OID indicates that Client 2 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 2 is cor…
1.3.6.1.4.1.20044.26.2.1.2.195.11Scalarpm1005AlmClient3InitFailread-onlycurrentClient3 Init Fail :This OID indicates that Client 3 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 3 is cor…
1.3.6.1.4.1.20044.26.2.1.2.195.12Scalarpm1005AlmClient4InitFailread-onlycurrentClient4 Init Fail :This OID indicates that Client 4 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 4 is cor…
1.3.6.1.4.1.20044.26.2.1.2.195.13Scalarpm1005AlmClient5InitFailread-onlycurrentClient5 Init Fail :This OID indicates that Client 5 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 5 is cor…
1.3.6.1.4.1.20044.26.2.1.2.195.14Scalarpm1005AlmClient6InitFailread-onlycurrentClient6 Init Fail :This OID indicates that Client 6 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 6 is cor…
1.3.6.1.4.1.20044.26.2.1.2.195.15Scalarpm1005AlmClient7InitFailread-onlycurrentClient7 Init Fail :This OID indicates that Client 7 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 7 is cor…
1.3.6.1.4.1.20044.26.2.1.2.195.16Scalarpm1005AlmClient8InitFailread-onlycurrentClient8 Init Fail :This OID indicates that Client 8 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 8 is cor…
1.3.6.1.4.1.20044.26.2.1.3Nodepm1005AlmOtherCrit
1.3.6.1.4.1.20044.26.2.1.3.0Nodepm1005AlmsynthAlm0
1.3.6.1.4.1.20044.26.2.1.3.0.9Scalarpm1005AlmModGlobFailread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the PM <Condtype> MOD_GLOB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> sy…
1.3.6.1.4.1.20044.26.2.1.3.0.15Scalarpm1005AlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.26.2.1.3.0.16Scalarpm1005AlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.26.2.2Nodepm1005AlmClient
1.3.6.1.4.1.20044.26.2.2.1Nodepm1005AlmClientNurg
1.3.6.1.4.1.20044.26.2.2.1.48Tablepm1005AlmsfpWarnDdmTablenot-accessiblecurrentList of pm1005AlmsfpWarnDdm Article
1.3.6.1.4.1.20044.26.2.2.1.48.1Rowpm1005AlmsfpWarnDdmEntrynot-accessiblecurrentRow definition for the pm1005AlmsfpWarnDdm table
1.3.6.1.4.1.20044.26.2.2.1.48.1.1Columnpm1005AlmsfpWarnDdmIndexread-onlycurrentIndex definition for the pm1005AlmsfpWarnDdm table
1.3.6.1.4.1.20044.26.2.2.1.48.1.2Columnpm1005AlmTxPwLowWngPortnread-onlycurrentClient SFP Tx Power Low Warning :Warning indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> TX…
1.3.6.1.4.1.20044.26.2.2.1.48.1.3Columnpm1005AlmTxPwrHighWngPortnread-onlycurrentClient SFP Tx Power High Warning :Warning indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.26.2.2.1.48.1.4Columnpm1005AlmTxBiasLowWngPortnread-onlycurrentClient SFP Bias Low Warning :Warning indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.26.2.2.1.48.1.5Columnpm1005AlmTxBiasHighWngPortnread-onlycurrentClient SFP Bias High Warning :Warning indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.26.2.2.1.48.1.6Columnpm1005AlmVccLowWngPortnread-onlycurrentClient SFP Power Supply Low Warning :Warning indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.26.2.2.1.48.1.7Columnpm1005AlmVccHighWngPortnread-onlycurrentClient SFP Power Supply High Warning :Warning indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condty…
1.3.6.1.4.1.20044.26.2.2.1.48.1.8Columnpm1005AlmTempLowWngPortnread-onlycurrentClient SFP Temp Low Warning :Warning indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> TEMP_LO…
1.3.6.1.4.1.20044.26.2.2.1.48.1.9Columnpm1005AlmTempHighWngPortnread-onlycurrentClient SFP Temp High Warning :Warning indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> TEMP_…
1.3.6.1.4.1.20044.26.2.2.1.48.1.16Columnpm1005AlmRxPwrLowWngPortnread-onlycurrentClient SFP Rx Power Low Warning :Warning indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> RX_…
1.3.6.1.4.1.20044.26.2.2.1.48.1.17Columnpm1005AlmRxPwrHighWngPortnread-onlycurrentClient SFP Rx Power High Warning :Warning indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> R…
1.3.6.1.4.1.20044.26.2.2.2Nodepm1005AlmClientUrg
1.3.6.1.4.1.20044.26.2.2.2.32Tablepm1005AlmsfpAlmDdmTablenot-accessiblecurrentList of pm1005AlmsfpAlmDdm Article
1.3.6.1.4.1.20044.26.2.2.2.32.1Rowpm1005AlmsfpAlmDdmEntrynot-accessiblecurrentRow definition for the pm1005AlmsfpAlmDdm table
1.3.6.1.4.1.20044.26.2.2.2.32.1.1Columnpm1005AlmsfpAlmDdmIndexread-onlycurrentIndex definition for the pm1005AlmsfpAlmDdm table
1.3.6.1.4.1.20044.26.2.2.2.32.1.2Columnpm1005AlmTxPwrLowAlaPortnread-onlycurrentClient SFP Tx Power Low :Alarm indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> TX_PWR_LOW_A…
1.3.6.1.4.1.20044.26.2.2.2.32.1.3Columnpm1005AlmTxPwrHighAlaPortnread-onlycurrentClient SFP Tx Power High :Alarm indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> TX_PWR_HIG…
1.3.6.1.4.1.20044.26.2.2.2.32.1.4Columnpm1005AlmTxBiasLowAlaPortnread-onlycurrentClient SFP Bias Low :Alarm indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> TX_BIAS_LO…
1.3.6.1.4.1.20044.26.2.2.2.32.1.5Columnpm1005AlmTxBiasHighAlaPortnread-onlycurrentClient SFP Bias High :Alarm indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype> TX_BIAS_…
1.3.6.1.4.1.20044.26.2.2.2.32.1.6Columnpm1005AlmVccLowAlaPortnread-onlycurrentClient SFP Power Supply Low :Alarm indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype> VCC_LOW_…
1.3.6.1.4.1.20044.26.2.2.2.32.1.7Columnpm1005AlmVccHighAlaPortnread-onlycurrentClient SFP Power Supply High :Alarm indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condtype> VCC_HI…
1.3.6.1.4.1.20044.26.2.2.2.32.1.8Columnpm1005AlmTempLowAlaPortnread-onlycurrentClient SFP Temp Low :Alarm indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> TEMP_LOW_ALA_1 <P…
1.3.6.1.4.1.20044.26.2.2.2.32.1.9Columnpm1005AlmTempHighAlaPortnread-onlycurrentClient SFP Temp High :Alarm indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> TEMP_HIGH_ALA_1…
1.3.6.1.4.1.20044.26.2.2.2.32.1.16Columnpm1005AlmRxPwrLowAlaPortnread-onlycurrentClient SFP Rx Power Low :Alarm indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> RX_PWR_LOW_AL…
1.3.6.1.4.1.20044.26.2.2.2.32.1.17Columnpm1005AlmRxPwrHighAlaPortnread-onlycurrentClient SFP Rx Power High :Alarm indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> RX_PWR_HIGH…
1.3.6.1.4.1.20044.26.2.2.3Nodepm1005AlmClientCrit
1.3.6.1.4.1.20044.26.2.2.3.8Tablepm1005AlmsynthAlmPortTablenot-accessiblecurrentList of pm1005AlmsynthAlmPort Article
1.3.6.1.4.1.20044.26.2.2.3.8.1Rowpm1005AlmsynthAlmPortEntrynot-accessiblecurrentRow definition for the pm1005AlmsynthAlmPort table
1.3.6.1.4.1.20044.26.2.2.3.8.1.1Columnpm1005AlmsynthAlmPortIndexread-onlycurrentIndex definition for the pm1005AlmsynthAlmPort table
1.3.6.1.4.1.20044.26.2.2.3.8.1.2Columnpm1005AlmSfpAbsentPortnread-onlycurrentClient SFP Absent :This OID indicates that the SFP module is not present in the client port. <Help> This alarm indicates if the client transceiver is present. …
1.3.6.1.4.1.20044.26.2.2.3.8.1.3Columnpm1005AlmDdmAbsentPortnread-onlycurrentDDM Supported On Client SFP :This OID indicates that the Client SFP module supports the Digital Diagnostic Monitoring function <Help> This status indicates if …
1.3.6.1.4.1.20044.26.2.2.3.8.1.5Columnpm1005AlmHwFailAccPortnread-onlycurrentClient HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Condtype> HW_FAIL_ACC_1 <Probcause> equipmentMalfunction (16)…
1.3.6.1.4.1.20044.26.2.2.3.8.1.6Columnpm1005AlmDwLsdPortnread-onlycurrentClient SFP Laser Shutdown :This OID indicates the Client SFP transmitter output is ON. <Help> This status indicates if the client transceiver laser is ON or OF…
1.3.6.1.4.1.20044.26.2.2.3.8.1.7Columnpm1005AlmClientLocalOosPortnread-onlycurrentLocal Client Port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local c…
1.3.6.1.4.1.20044.26.2.2.3.8.1.8Columnpm1005AlmClientRemoteOosPortnread-onlycurrentRemote Client Port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the remot…
1.3.6.1.4.1.20044.26.2.2.3.8.1.9Columnpm1005AlmDwCaisPortnread-onlycurrentClient AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indicates if a Client Alarm Indication Signal is…
1.3.6.1.4.1.20044.26.2.2.3.8.1.10Columnpm1005AlmSfpDdmWarningPortnread-onlycurrentWarning On Client SFP DDM :This OID indicates a warning is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Warning has been detecte…
1.3.6.1.4.1.20044.26.2.2.3.8.1.11Columnpm1005AlmSfpDdmAlmPortnread-onlycurrentAlarm On Client SFP DDM :This OID indicates an alarm is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Alarm has been detected on …
1.3.6.1.4.1.20044.26.2.2.3.8.1.13Columnpm1005AlmFailAccPortnread-onlycurrentClient Access Fail :This OID indicates a failure on the Client port <Condtype> FAIL_ACC_1 <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12)…
1.3.6.1.4.1.20044.26.2.2.3.8.1.17Columnpm1005AlmUpCsfPortnread-onlycurrentClient Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu…
1.3.6.1.4.1.20044.26.2.2.3.16Tablepm1005AlmaccessioAlmTablenot-accessiblecurrentList of pm1005AlmaccessioAlm Article
1.3.6.1.4.1.20044.26.2.2.3.16.1Rowpm1005AlmaccessioAlmEntrynot-accessiblecurrentRow definition for the pm1005AlmaccessioAlm table
1.3.6.1.4.1.20044.26.2.2.3.16.1.1Columnpm1005AlmaccessioAlmIndexread-onlycurrentIndex definition for the pm1005AlmaccessioAlm table
1.3.6.1.4.1.20044.26.2.2.3.16.1.2Columnpm1005AlmDwLasFailPortnread-onlycurrentClient SFP Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the client port (this alarm reports the transmitter failure alarm …
1.3.6.1.4.1.20044.26.2.2.3.16.1.5Columnpm1005AlmUpLosPortnread-onlycurrentClient Input Loss Of Signal :This OID indicates that no signal is present on the SFP of the client port <Help> This alarm indicates if an optical signal is det…
1.3.6.1.4.1.20044.26.2.2.3.72Tablepm1005AlmmapperDeAlmTablenot-accessiblecurrentList of pm1005AlmmapperDeAlm Article
1.3.6.1.4.1.20044.26.2.2.3.72.1Rowpm1005AlmmapperDeAlmEntrynot-accessiblecurrentRow definition for the pm1005AlmmapperDeAlm table
1.3.6.1.4.1.20044.26.2.2.3.72.1.1Columnpm1005AlmmapperDeAlmIndexread-onlycurrentIndex definition for the pm1005AlmmapperDeAlm table
1.3.6.1.4.1.20044.26.2.2.3.72.1.2Columnpm1005AlmUpAccOosPortnread-onlycurrentClient Loss Of 10b/8b Synchro :This OID indicates the upstream client input port has lost synchronization on its 10B/8B decoder <Help> This alarms indicates if…
1.3.6.1.4.1.20044.26.2.2.3.72.1.11Columnpm1005AlmUpBufferOvlPortnread-onlycurrentClient Upstream Buffer Overload :This OID indicates that the rate adaptation buffer for client port is in overload. <Help> This alarm indicates if there is a u…
1.3.6.1.4.1.20044.26.2.2.3.72.1.12Columnpm1005AlmDwCsfDetPortnread-onlycurrentClient Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client…
1.3.6.1.4.1.20044.26.2.2.3.72.1.15Columnpm1005AlmDwBufferOvlPortnread-onlycurrentClient Downstream Buffer Overload :This OID indicates that the de-mapper buffer for client port is in overload. <Help> This alarm indicates if there is a downs…
1.3.6.1.4.1.20044.26.2.3Nodepm1005AlmLine
1.3.6.1.4.1.20044.26.2.3.1Nodepm1005AlmLineNurg
1.3.6.1.4.1.20044.26.2.3.1.209Tablepm1005AlmlineXfp1WarningsTablenot-accessiblecurrentList of pm1005AlmlineXfp1Warnings Article
1.3.6.1.4.1.20044.26.2.3.1.209.1Rowpm1005AlmlineXfp1WarningsEntrynot-accessiblecurrentRow definition for the pm1005AlmlineXfp1Warnings table
1.3.6.1.4.1.20044.26.2.3.1.209.1.1Columnpm1005AlmlineXfp1WarningsIndexread-onlycurrentIndex definition for the pm1005AlmlineXfp1Warnings table
1.3.6.1.4.1.20044.26.2.3.1.209.1.2Columnpm1005AlmTxPowerLowWarningPortnread-onlycurrentLine Optical Tx Power Low Warning :Warning indicating that the XFP/OTX transmitter transmitter output power is lower than the threshold value written in the XF…
1.3.6.1.4.1.20044.26.2.3.1.209.1.3Columnpm1005AlmTxPowerHighWarningPortnread-onlycurrentLine Optical Tx Power High Warning :Warning indicating that the XFP/OTX transmitter transmitter output power is higher than the threshold value written in the …
1.3.6.1.4.1.20044.26.2.3.1.209.1.4Columnpm1005AlmTxBiasLowWarningPortnread-onlycurrentLine Transceiver Bias Low Warning :Warning indicating that the XFP/OTX transmitter laser bias current is lower than the threshold value written in the XFP/OTX …
1.3.6.1.4.1.20044.26.2.3.1.209.1.5Columnpm1005AlmTxBiasHighWarningPortnread-onlycurrentLine Transceiver Bias High Warning :Warning indicating that the XFP/OTX transmitter laser bias current is higher than the threshold value written in the XFP EE…
1.3.6.1.4.1.20044.26.2.3.1.209.1.8Columnpm1005AlmTempLowWarningPortnread-onlycurrentLine Transceiver Temp Low Warning :Warning indicating that the XFP/OTX temperature is lower than the threshold value written in the XFP/OTX EEPROM <Condtype> T…
1.3.6.1.4.1.20044.26.2.3.1.209.1.9Columnpm1005AlmTempHighWarningPortnread-onlycurrentLine Transceiver Temp High Warning :Warning indicating that the XFP/OTX temperature is higher than the threshold value written in the XFP EEPROM <Condtype> TEM…
1.3.6.1.4.1.20044.26.2.3.1.209.1.16Columnpm1005AlmRxPowerLowWarningPortnread-onlycurrentLine Optical Rx Power Low Warning :Warning indicating that the XFP received optical power is lower than the threshold value written in the XFP EEPROM <Condtype…
1.3.6.1.4.1.20044.26.2.3.1.209.1.17Columnpm1005AlmRxPowerHighWarningPortnread-onlycurrentLine Optical Rx Power High Warning :Warning indicating that the XFP received optical power is higher than the threshold value written in the XFP EEPROM <Condty…
1.3.6.1.4.1.20044.26.2.3.1.225Tablepm1005AlmlineOtx1TlhWarningsTablenot-accessiblecurrentList of pm1005AlmlineOtx1TlhWarnings Article
1.3.6.1.4.1.20044.26.2.3.1.225.1Rowpm1005AlmlineOtx1TlhWarningsEntrynot-accessiblecurrentRow definition for the pm1005AlmlineOtx1TlhWarnings table
1.3.6.1.4.1.20044.26.2.3.1.225.1.1Columnpm1005AlmlineOtx1TlhWarningsIndexread-onlycurrentIndex definition for the pm1005AlmlineOtx1TlhWarnings table
1.3.6.1.4.1.20044.26.2.3.1.225.1.6Columnpm1005AlmLineModulatorAgingHighWarningPortnread-onlycurrentLine Modulator Aging High Warning :Warning indicating the Line OTX TLH modulator aging is higher than the threshold written in the EEPROM <Condtype> LINE_MODUL…
1.3.6.1.4.1.20044.26.2.3.1.225.1.7Columnpm1005AlmLineAgingHighWarningPortnread-onlycurrentLine OTX TLH Aging High Warning :Warning indicating the Line OTX TLH aging is higher than the threshold written in the EEPROM <Condtype> LINE_AGING_HIGH_WARNIN…
1.3.6.1.4.1.20044.26.2.3.1.225.1.13Columnpm1005AlmLineFreqDevHighWarningPortnread-onlycurrentLine Freq. Deviation High Warning :Warning indicating the Line OTX TLH frequency deviation is higher than the threshold written in the EEPROM <Condtype> LINE_F…
1.3.6.1.4.1.20044.26.2.3.1.225.1.15Columnpm1005AlmLineLaserTempHighWarningPortnread-onlycurrentLine Laser Temp. High Warning :Warning indicating the Line OTX TLH laser temperature is higher than the threshold written in the EEPROM <Condtype> LINE_LASER_T…
1.3.6.1.4.1.20044.26.2.3.2Nodepm1005AlmLineUrg
1.3.6.1.4.1.20044.26.2.3.2.129Tablepm1005AlmdfrmBerTablenot-accessiblecurrentList of pm1005AlmdfrmBer Article
1.3.6.1.4.1.20044.26.2.3.2.129.1Rowpm1005AlmdfrmBerEntrynot-accessiblecurrentRow definition for the pm1005AlmdfrmBer table
1.3.6.1.4.1.20044.26.2.3.2.129.1.1Columnpm1005AlmdfrmBerIndexread-onlycurrentIndex definition for the pm1005AlmdfrmBer table
1.3.6.1.4.1.20044.26.2.3.2.129.1.2Columnpm1005AlmLineSignalDegradePortnread-onlycurrentCustom Line Signal Degrade :This OID indicates that the line input signal is DEGRADE. The assertion hysteresis can customized by the host <Condtype> LINE_SIGNA…
1.3.6.1.4.1.20044.26.2.3.2.129.1.3Columnpm1005AlmLineSignalFailPortnread-onlycurrentCustom Line Signal Fail :This OID indicates that the line input signal is FAIL. The assertion hysteresis can be customized by the host <Condtype> LINE_SIGNAL_F…
1.3.6.1.4.1.20044.26.2.3.2.129.1.6Columnpm1005AlmLineDegradePortnread-onlycurrentFixed Line Signal Degrade :This OID indicates that the line input signal is DEGRADE. The assetion hysteresis is fixed to 10-8 (assertion) and 10-9 (de-assertio…
1.3.6.1.4.1.20044.26.2.3.2.208Tablepm1005AlmlineXfp1AlarmTablenot-accessiblecurrentList of pm1005AlmlineXfp1Alarm Article
1.3.6.1.4.1.20044.26.2.3.2.208.1Rowpm1005AlmlineXfp1AlarmEntrynot-accessiblecurrentRow definition for the pm1005AlmlineXfp1Alarm table
1.3.6.1.4.1.20044.26.2.3.2.208.1.1Columnpm1005AlmlineXfp1AlarmIndexread-onlycurrentIndex definition for the pm1005AlmlineXfp1Alarm table
1.3.6.1.4.1.20044.26.2.3.2.208.1.2Columnpm1005AlmTxPowerLowAlarmPortnread-onlycurrentLine Optical Tx Power Low :Alarm indicating that the XFP/OTX transmitter transmitter output power is lower than the threshold value written in the XFP/OTX EEPR…
1.3.6.1.4.1.20044.26.2.3.2.208.1.3Columnpm1005AlmTxPowerHighAlarmPortnread-onlycurrentLine Optical Tx Power High :Alarm indicating that the XFP/OTX transmitter transmitter output power is higher than the threshold value written in the XFP EEPROM…
1.3.6.1.4.1.20044.26.2.3.2.208.1.4Columnpm1005AlmTxBiasLowAlarmPortnread-onlycurrentLine Transceiver Bias Low :Alarm indicating that the XFP/OTX transmitter laser bias current is lower than the threshold value written in the XFP/OTX EEPROM <Co…
1.3.6.1.4.1.20044.26.2.3.2.208.1.5Columnpm1005AlmTxBiasHighAlarmPortnread-onlycurrentLine Transceiver Bias High :Alarm indicating that the XFP/OTX transmitter laser bias current is higher than the threshold value written in the XFP EEPROM <Cond…
1.3.6.1.4.1.20044.26.2.3.2.208.1.8Columnpm1005AlmTempLowAlarmPortnread-onlycurrentLine Transceiver Temp Low :Alarm indicating that the XFP/OTX temperature is lower than the threshold value written in the XFP/OTX EEPROM <Condtype> TEMP_LOW_AL…
1.3.6.1.4.1.20044.26.2.3.2.208.1.9Columnpm1005AlmTempHighAlarmPortnread-onlycurrentLine Transceiver Temp High :Alarm indicating that the XFP/OTX temperature is higher than the threshold value written in the XFP EEPROM <Condtype> TEMP_HIGH_ALA…
1.3.6.1.4.1.20044.26.2.3.2.208.1.16Columnpm1005AlmRxPowerLowAlarmPortnread-onlycurrentLine Optical Rx Power Low :Alarm indicating that the XFP received optical power is lower than the threshold value written in the XFP EEPROM <Condtype> RX_POWER…
1.3.6.1.4.1.20044.26.2.3.2.208.1.17Columnpm1005AlmRxPowerHighAlarmPortnread-onlycurrentLine Optical Rx Power High :Alarm indicating that the XFP received optical power is higher than the threshold value written in the XFP EEPROM <Condtype> RX_POW…
1.3.6.1.4.1.20044.26.2.3.2.212Tablepm1005AlmlineXfp1SupplyAlarmTablenot-accessiblecurrentList of pm1005AlmlineXfp1SupplyAlarm Article
1.3.6.1.4.1.20044.26.2.3.2.212.1Rowpm1005AlmlineXfp1SupplyAlarmEntrynot-accessiblecurrentRow definition for the pm1005AlmlineXfp1SupplyAlarm table
1.3.6.1.4.1.20044.26.2.3.2.212.1.1Columnpm1005AlmlineXfp1SupplyAlarmIndexread-onlycurrentIndex definition for the pm1005AlmlineXfp1SupplyAlarm table
1.3.6.1.4.1.20044.26.2.3.2.212.1.2Columnpm1005AlmVee5LowAlarmPortnread-onlycurrentVEE5 Power Supply Low :Alarm indicating the XFP/OTX VEE5 power supply is lower than the threshold written in the EEPROM <Condtype> VEE5_LOW_ALARM_1 <Probcause>…
1.3.6.1.4.1.20044.26.2.3.2.212.1.3Columnpm1005AlmVee5HighAlarmPortnread-onlycurrentVEE5 Power Supply High :Alarm indicating the XFP/OTX VEE5 power supply is higher than the threshold written in the EEPROM <Condtype> VEE5_HIGH_ALARM_1 <Probcau…
1.3.6.1.4.1.20044.26.2.3.2.212.1.4Columnpm1005AlmVcc2LowAlarmPortnread-onlycurrentVCC2 Power Supply Low :Alarm indicating the XFP/OTX VCC2 power supply is lower than the threshold written in the EEPROM <Condtype> VCC2_LOW_ALARM_1 <Probcause>…
1.3.6.1.4.1.20044.26.2.3.2.212.1.5Columnpm1005AlmVcc2HighAlarmPortnread-onlycurrentVCC2 Power Supply High :Alarm indicating the XFP/OTX VCC2 power supply is higher than the threshold written in the EEPROM <Condtype> VCC2_HIGH_ALARM_1 <Probcau…
1.3.6.1.4.1.20044.26.2.3.2.212.1.6Columnpm1005AlmVcc3LowAlarmPortnread-onlycurrentVCC3 Power Supply Low :Alarm indicating the XFP/OTX VCC3 power supply is lower than the threshold written in the EEPROM <Condtype> VCC3_LOW_ALARM_1 <Probcause>…
1.3.6.1.4.1.20044.26.2.3.2.212.1.7Columnpm1005AlmVcc3HighAlarmPortnread-onlycurrentVCC3 Power Supply High :Alarm indicating the XFP/OTX VCC3 power supply is higher than the threshold written in the EEPROM <Condtype> VCC3_HIGH_ALARM_1 <Probcau…
1.3.6.1.4.1.20044.26.2.3.2.212.1.8Columnpm1005AlmVcc5LowAlarmPortnread-onlycurrentVCC5 Power Supply Low :Alarm indicating the XFP/OTX VCC5 power supply is lower than the threshold written in the EEPROM <Condtype> VCC5_LOW_ALARM_1 <Probcause>…
1.3.6.1.4.1.20044.26.2.3.2.212.1.9Columnpm1005AlmVcc5HighAlarmPortnread-onlycurrentVCC5 Power Supply High :Alarm indicating the XFP/OTX VCC5 power supply is higher than the threshold written in the EEPROM <Condtype> VCC5_HIGH_ALARM_1 <Probcau…
1.3.6.1.4.1.20044.26.2.3.2.212.1.10Columnpm1005AlmVee5LowWarningPortnread-onlycurrentVEE5 Power Supply Low Warning :Warning indicating the XFP/OTX VEE5 power supply is lower than the threshold written in the EEPROM <Condtype> VEE5_LOW_WARNING_1…
1.3.6.1.4.1.20044.26.2.3.2.212.1.11Columnpm1005AlmVee5HighWarningPortnread-onlycurrentVEE5 Power Supply High Warning :Warning indicating the XFP/OTX VEE5 power supply is higher than the threshold written in the EEPROM <Condtype> VEE5_HIGH_WARNIN…
1.3.6.1.4.1.20044.26.2.3.2.212.1.12Columnpm1005AlmVcc2LowWarningPortnread-onlycurrentVCC2 Power Supply Low Warning :Warning indicating the XFP/OTX VCC2 power supply is lower than the threshold written in the EEPROM <Condtype> VCC2_LOW_WARNING_1…
1.3.6.1.4.1.20044.26.2.3.2.212.1.13Columnpm1005AlmVcc2HighWarningPortnread-onlycurrentVCC2 Power Supply High Warning :Warning indicating the XFP/OTX VCC2 power supply is higher than the threshold written in the EEPROM <Condtype> VCC2_HIGH_WARNIN…
1.3.6.1.4.1.20044.26.2.3.2.212.1.14Columnpm1005AlmVcc3LowWarningPortnread-onlycurrentVCC3 Power Supply Low Warning :Warning indicating the XFP/OTX VCC3 power supply is lower than the threshold written in the EEPROM <Condtype> VCC3_LOW_WARNING_1…
1.3.6.1.4.1.20044.26.2.3.2.212.1.15Columnpm1005AlmVcc3HighWarningPortnread-onlycurrentVCC3 Power Supply High Warning :Warning indicating the XFP/OTX VCC3 power supply is higher than the threshold written in the EEPROM <Condtype> VCC3_HIGH_WARNIN…
1.3.6.1.4.1.20044.26.2.3.2.212.1.16Columnpm1005AlmVcc5LowWarningPortnread-onlycurrentVCC5 Power Supply Low Warning :Warning indicating the XFP/OTX VCC5 power supply is lower than the threshold written in the EEPROM <Condtype> VCC5_LOW_WARNING_1…
1.3.6.1.4.1.20044.26.2.3.2.212.1.17Columnpm1005AlmVcc5HighWarningPortnread-onlycurrentVCC5 Power Supply High Warning :Warning indicating the XFP/OTX VCC5 power supply is higher than the threshold written in the EEPROM <Condtype> VCC5_HIGH_WARNIN…
1.3.6.1.4.1.20044.26.2.3.2.224Tablepm1005AlmlineOtx1TlhAlarmsTablenot-accessiblecurrentList of pm1005AlmlineOtx1TlhAlarms Article
1.3.6.1.4.1.20044.26.2.3.2.224.1Rowpm1005AlmlineOtx1TlhAlarmsEntrynot-accessiblecurrentRow definition for the pm1005AlmlineOtx1TlhAlarms table
1.3.6.1.4.1.20044.26.2.3.2.224.1.1Columnpm1005AlmlineOtx1TlhAlarmsIndexread-onlycurrentIndex definition for the pm1005AlmlineOtx1TlhAlarms table
1.3.6.1.4.1.20044.26.2.3.2.224.1.6Columnpm1005AlmLineModulatorAgingHighAlaPortnread-onlycurrentLine Modulator Aging High Alarm :Alarm indicating the Line OTX TLH modulator aging is higher than the threshold written in the EEPROM <Condtype> LINE_MODULATOR…
1.3.6.1.4.1.20044.26.2.3.2.224.1.7Columnpm1005AlmLineAgingHighAlaPortnread-onlycurrentLine OTX TLH Aging High Alarm :Alarm indicating the Line OTX TLH aging is higher than the threshold written in the EEPROM <Condtype> LINE_AGING_HIGH_ALA_1 <Pro…
1.3.6.1.4.1.20044.26.2.3.2.224.1.13Columnpm1005AlmLineFreqDevHighAlaPortnread-onlycurrentLine Freq. Deviation High Alarm :Alarm indicating the Line OTX TLH frequency deviation is higher than the threshold written in the EEPROM <Condtype> LINE_FREQ_…
1.3.6.1.4.1.20044.26.2.3.2.224.1.15Columnpm1005AlmLineLaserTempHighAlaPortnread-onlycurrentLine Laser Temp. High Alarm :Alarm indicating the Line OTX TLH laser temperature is higher than the threshold written in the EEPROM <Condtype> LINE_LASER_TEMP_…
1.3.6.1.4.1.20044.26.2.3.3Nodepm1005AlmLineCrit
1.3.6.1.4.1.20044.26.2.3.3.7Tablepm1005AlmsynthAlmLineTablenot-accessiblecurrentList of pm1005AlmsynthAlmLine Article
1.3.6.1.4.1.20044.26.2.3.3.7.1Rowpm1005AlmsynthAlmLineEntrynot-accessiblecurrentRow definition for the pm1005AlmsynthAlmLine table
1.3.6.1.4.1.20044.26.2.3.3.7.1.1Columnpm1005AlmsynthAlmLineIndexread-onlycurrentIndex definition for the pm1005AlmsynthAlmLine table
1.3.6.1.4.1.20044.26.2.3.3.7.1.2Columnpm1005AlmXfpAbsentPortnread-onlycurrentLine Optical Module Absent :This OID indicates that the line optical interface (XFP or OTX) is not plugged in. <Help> This alarm indicates if the line transcei…
1.3.6.1.4.1.20044.26.2.3.3.7.1.3Columnpm1005AlmXfpInitNotComplPortnread-onlycurrentLine Optical Module Ready :This OID indicates that the optical interface (XFP or OTX) is not operational. <Help> This status indicates if the line transceiver …
1.3.6.1.4.1.20044.26.2.3.3.7.1.5Columnpm1005AlmLineHwFailPortnread-onlycurrentLine Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Condtype> LINE_HW_FAIL <Probcause> equipmentMalfunction (1…
1.3.6.1.4.1.20044.26.2.3.3.7.1.6Columnpm1005AlmXfpTxOffPortnread-onlycurrentLine Optical Module Laser Shutdown :This OID indicates the line optical output power is on <Help> This status indicates if the line transceiver laser is ON or …
1.3.6.1.4.1.20044.26.2.3.3.7.1.7Columnpm1005AlmLineLocalOosPortnread-onlycurrentLine Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service…
1.3.6.1.4.1.20044.26.2.3.3.7.1.9Columnpm1005AlmUpRdiInsPortnread-onlycurrentMS-RDI/L-RDI Inserted On Line :This OID indicates an upstream MS-RDI/L-RDI has been inserted in the outgoing 10 Gb/s SDH/SONET signal. <Help> This status indic…
1.3.6.1.4.1.20044.26.2.3.3.7.1.10Columnpm1005AlmLineDdmWarningPortnread-onlycurrentWarning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Warni…
1.3.6.1.4.1.20044.26.2.3.3.7.1.11Columnpm1005AlmLineDdmAlmPortnread-onlycurrentAlarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Alarm ha…
1.3.6.1.4.1.20044.26.2.3.3.7.1.13Columnpm1005AlmLineFailPortnread-onlycurrentLine Port Failure :This OID indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12) <Po…
1.3.6.1.4.1.20044.26.2.3.3.7.1.17Columnpm1005AlmLineActivePortnread-onlycurrentLine Active :This bit indicates the line #n is active on receive side <Help> This status indicates whether the line is active or standby. <Condtype> LINE_ACTIV…
1.3.6.1.4.1.20044.26.2.3.3.128Tablepm1005AlmdfrmAlmTablenot-accessiblecurrentList of pm1005AlmdfrmAlm Article
1.3.6.1.4.1.20044.26.2.3.3.128.1Rowpm1005AlmdfrmAlmEntrynot-accessiblecurrentRow definition for the pm1005AlmdfrmAlm table
1.3.6.1.4.1.20044.26.2.3.3.128.1.1Columnpm1005AlmdfrmAlmIndexread-onlycurrentIndex definition for the pm1005AlmdfrmAlm table
1.3.6.1.4.1.20044.26.2.3.3.128.1.2Columnpm1005AlmDwAisDetPortnread-onlycurrentMS-AIS/L-AIS Detected On Line Input :This OID indicates that an MS-AIS has been detected on incoming OC-48c/STM-16c input signal <Help> This alarm indicates if…
1.3.6.1.4.1.20044.26.2.3.3.128.1.3Columnpm1005AlmDwRdiDetPortnread-onlycurrentMS-RDI/L-RDI Detected On Line Input :This OID indicates that an MS-RDI has been detected on incoming OC-48c/STM-16c input signal <Help> This alarm indicates if…
1.3.6.1.4.1.20044.26.2.3.3.128.1.4Columnpm1005AlmDwOofPortnread-onlycurrentSONET/SDH Line Out Of Frame :This OID indicates that an Out Of Frame has been detected on incoming OC-48c/STM-16c input signal <Help> This alarm indicates if t…
1.3.6.1.4.1.20044.26.2.3.3.128.1.5Columnpm1005AlmDwLofPortnread-onlycurrentSONET/SDH Line Loss Of Frame :This OID indicates that a Loss Of Frame has been detected on incoming OC-48c/STM-16c input signal <Help> This alarm indicates if …
1.3.6.1.4.1.20044.26.2.3.3.133Tablepm1005AlmlineSyncAlarmsTablenot-accessiblecurrentList of pm1005AlmlineSyncAlarms Article
1.3.6.1.4.1.20044.26.2.3.3.133.1Rowpm1005AlmlineSyncAlarmsEntrynot-accessiblecurrentRow definition for the pm1005AlmlineSyncAlarms table
1.3.6.1.4.1.20044.26.2.3.3.133.1.1Columnpm1005AlmlineSyncAlarmsIndexread-onlycurrentIndex definition for the pm1005AlmlineSyncAlarms table
1.3.6.1.4.1.20044.26.2.3.3.133.1.13Columnpm1005AlmDwLockerrPortnread-onlycurrentDownstream Clock Lock Error :This OID indicates that the deserializer input 10 Gb/s clock recovery is not locked. <Condtype> DW_LOCKERR <Probcause> receiveFail…
1.3.6.1.4.1.20044.26.2.3.3.133.1.14Columnpm1005AlmUpLockerrPortnread-onlycurrentUpstream Clock Lock Error :This OID indicates that the serializer output 10 Gb/s clock multiplier unit is not locked. <Condtype> UP_LOCKERR <Probcause> receive…
1.3.6.1.4.1.20044.26.2.3.3.133.1.17Columnpm1005AlmDwLosPortnread-onlycurrentLine Input Loss Of Signal :This OID indicates a loss of signal on the 10 Gb/s input. <Help> This alarm indicates if an optical signal is detected on the line t…
1.3.6.1.4.1.20044.26.2.3.3.211Tablepm1005AlmlineXfp1AlarmsTablenot-accessiblecurrentList of pm1005AlmlineXfp1Alarms Article
1.3.6.1.4.1.20044.26.2.3.3.211.1Rowpm1005AlmlineXfp1AlarmsEntrynot-accessiblecurrentRow definition for the pm1005AlmlineXfp1Alarms table
1.3.6.1.4.1.20044.26.2.3.3.211.1.1Columnpm1005AlmlineXfp1AlarmsIndexread-onlycurrentIndex definition for the pm1005AlmlineXfp1Alarms table
1.3.6.1.4.1.20044.26.2.3.3.211.1.3Columnpm1005AlmModNrPortnread-onlycurrentLine Optical Module Not Ready :This OID indicates that the module is unable to determine correct data. <Help> This alarm indicates if the line transceiver is r…
1.3.6.1.4.1.20044.26.2.3.3.211.1.4Columnpm1005AlmRxCdrNotLockedPortnread-onlycurrentLine Optical Rx CDR Unlocked :This OID indicates that a loss of lock on the receiving side CDR has been detected <Help> This alarm indicates if the Rx CDR is l…
1.3.6.1.4.1.20044.26.2.3.3.211.1.6Columnpm1005AlmRxNrPortnread-onlycurrentLine Optical Rx Not Ready :This OID indicates that a condition has arisen leading to invalid data on the receiving side. <Help> This alarm indicates if the Rx …
1.3.6.1.4.1.20044.26.2.3.3.211.1.7Columnpm1005AlmTxCdrNotLockedPortnread-onlycurrentLine Optical Tx CDR Unlocked :This OID indicates a loss of lock on the transmitting side CDR has been detected. <Help> This alarm indicates if the Tx CDR is lo…
1.3.6.1.4.1.20044.26.2.3.3.211.1.8Columnpm1005AlmTxFaultPortnread-onlycurrentLine Optical Tx Failure :This OID indicates a fault condition on the laser detected by the safety syste <Help> This alarm indicates if the laser of the line tr…
1.3.6.1.4.1.20044.26.2.3.3.211.1.9Columnpm1005AlmTxNrPortnread-onlycurrentLine Optical Tx Not Ready :This OID indicates a condition has arisen leading to invalid data on the transmitting side <Help> This alarm indicates if the Tx par…
1.3.6.1.4.1.20044.26.2.3.3.211.1.15Columnpm1005AlmWavelengthUnlockedPortnread-onlycurrentLine Optical Tx Wavelength Unlocked :This OID indicates that the wavelength error is exceeding the manufacturer tolerance <Help> This alarm indicates if the wa…
1.3.6.1.4.1.20044.26.2.3.3.211.1.16Columnpm1005AlmTecFaultPortnread-onlycurrentLine Optical Tx Temp Regul Failed :This OID indicates a failure on the TEC module <Help> This alarm indicates if the TEC of the line transceiver is in fail con…
1.3.6.1.4.1.20044.26.2.3.3.211.1.17Columnpm1005AlmApdSupplyFaultPortnread-onlycurrentLine Rx Photodiode Power Failed :This OID indicates a failure on the APD power supply <Help> This alarm indicates if the APD power supply is in fail condition …
1.3.6.1.4.1.20044.26.3Nodepm1005measures
1.3.6.1.4.1.20044.26.3.1Nodepm1005MesrOther
1.3.6.1.4.1.20044.26.3.1.0Scalarpm1005Mesrsynth0read-onlydeprecatedNot Used :This OID gives the unit used on AUX1 measurement of XFP#1 (Unit = )
1.3.6.1.4.1.20044.26.3.1.1Scalarpm1005Mesrsynth1read-onlydeprecatedNot Used :This OID gives the unit used on AUX2 measurement of XFP#1 (Unit = )
1.3.6.1.4.1.20044.26.3.2Nodepm1005MesrClient
1.3.6.1.4.1.20044.26.3.2.16Tablepm1005MesrtempMeasTablenot-accessiblecurrentList of pm1005MesrtempMeas Article
1.3.6.1.4.1.20044.26.3.2.16.1Rowpm1005MesrtempMeasEntrynot-accessiblecurrentRow definition for the pm1005MesrtempMeas table
1.3.6.1.4.1.20044.26.3.2.16.1.1Columnpm1005MesrtempMeasIndexread-onlycurrentIndex definition for the pm1005MesrtempMeas table
1.3.6.1.4.1.20044.26.3.2.16.1.2Columnpm1005MesrtempMeasPortnread-onlycurrentClient SFP Temperature :This OID gives the temperature value of the SFP plugged in port, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/25…
1.3.6.1.4.1.20044.26.3.2.24Tablepm1005MesrvoltMeasTablenot-accessiblecurrentList of pm1005MesrvoltMeas Article
1.3.6.1.4.1.20044.26.3.2.24.1Rowpm1005MesrvoltMeasEntrynot-accessiblecurrentRow definition for the pm1005MesrvoltMeas table
1.3.6.1.4.1.20044.26.3.2.24.1.1Columnpm1005MesrvoltMeasIndexread-onlycurrentIndex definition for the pm1005MesrvoltMeas table
1.3.6.1.4.1.20044.26.3.2.24.1.2Columnpm1005MesrvoltMeasPortnread-onlycurrentClient SFP Power Supply :This OID gives the 3V3 voltage value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/100…
1.3.6.1.4.1.20044.26.3.2.32Tablepm1005MesrbiasMeasTablenot-accessiblecurrentList of pm1005MesrbiasMeas Article
1.3.6.1.4.1.20044.26.3.2.32.1Rowpm1005MesrbiasMeasEntrynot-accessiblecurrentRow definition for the pm1005MesrbiasMeas table
1.3.6.1.4.1.20044.26.3.2.32.1.1Columnpm1005MesrbiasMeasIndexread-onlycurrentIndex definition for the pm1005MesrbiasMeas table
1.3.6.1.4.1.20044.26.3.2.32.1.2Columnpm1005MesrbiasMeasPortnread-onlycurrentClient SFP Laser Bias :This OID gives the bias value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA…
1.3.6.1.4.1.20044.26.3.2.40Tablepm1005MesrtxpwrMeasTablenot-accessiblecurrentList of pm1005MesrtxpwrMeas Article
1.3.6.1.4.1.20044.26.3.2.40.1Rowpm1005MesrtxpwrMeasEntrynot-accessiblecurrentRow definition for the pm1005MesrtxpwrMeas table
1.3.6.1.4.1.20044.26.3.2.40.1.1Columnpm1005MesrtxpwrMeasIndexread-onlycurrentIndex definition for the pm1005MesrtxpwrMeas table
1.3.6.1.4.1.20044.26.3.2.40.1.2Columnpm1005MesrtxpwrMeasPortnread-onlycurrentClient SFP Tx Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV…
1.3.6.1.4.1.20044.26.3.2.48Tablepm1005MesrrxpwrMeasTablenot-accessiblecurrentList of pm1005MesrrxpwrMeas Article
1.3.6.1.4.1.20044.26.3.2.48.1Rowpm1005MesrrxpwrMeasEntrynot-accessiblecurrentRow definition for the pm1005MesrrxpwrMeas table
1.3.6.1.4.1.20044.26.3.2.48.1.1Columnpm1005MesrrxpwrMeasIndexread-onlycurrentIndex definition for the pm1005MesrrxpwrMeas table
1.3.6.1.4.1.20044.26.3.2.48.1.2Columnpm1005MesrrxpwrMeasPortnread-onlycurrentClient SFP Rx Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-4…
1.3.6.1.4.1.20044.26.3.3Nodepm1005MesrLine
1.3.6.1.4.1.20044.26.3.3.208Tablepm1005Mesrxfp1LxModTempMeasTablenot-accessiblecurrentList of pm1005Mesrxfp1LxModTempMeas Article
1.3.6.1.4.1.20044.26.3.3.208.1Rowpm1005Mesrxfp1LxModTempMeasEntrynot-accessiblecurrentRow definition for the pm1005Mesrxfp1LxModTempMeas table
1.3.6.1.4.1.20044.26.3.3.208.1.1Columnpm1005Mesrxfp1LxModTempMeasIndexread-onlycurrentIndex definition for the pm1005Mesrxfp1LxModTempMeas table
1.3.6.1.4.1.20044.26.3.3.208.1.2Columnpm1005Mesrxfp1LxModTempMeasPortnread-onlycurrentLine Optical Module Temperature :This OID gives the temperature of the XFP or OTX plugged in line#n, read from the DDM (Digital Diagnostic Monitoring) (Tempera…
1.3.6.1.4.1.20044.26.3.3.209Tablepm1005Mesrxfp1ReservedTablenot-accessibledeprecatedList of pm1005Mesrxfp1Reserved Article
1.3.6.1.4.1.20044.26.3.3.209.1Rowpm1005Mesrxfp1ReservedEntrynot-accessibledeprecatedRow definition for the pm1005Mesrxfp1Reserved table
1.3.6.1.4.1.20044.26.3.3.209.1.1Columnpm1005Mesrxfp1ReservedIndexread-onlydeprecatedIndex definition for the pm1005Mesrxfp1Reserved table
1.3.6.1.4.1.20044.26.3.3.209.1.2Columnpm1005Mesrxfp1ReservedPortnread-onlydeprecatedNot Used :Reserved
1.3.6.1.4.1.20044.26.3.3.210Tablepm1005Mesrxfp1LoBiasCurrentMeasTablenot-accessiblecurrentList of pm1005Mesrxfp1LoBiasCurrentMeas Article
1.3.6.1.4.1.20044.26.3.3.210.1Rowpm1005Mesrxfp1LoBiasCurrentMeasEntrynot-accessiblecurrentRow definition for the pm1005Mesrxfp1LoBiasCurrentMeas table
1.3.6.1.4.1.20044.26.3.3.210.1.1Columnpm1005Mesrxfp1LoBiasCurrentMeasIndexread-onlycurrentIndex definition for the pm1005Mesrxfp1LoBiasCurrentMeas table
1.3.6.1.4.1.20044.26.3.3.210.1.2Columnpm1005Mesrxfp1LoBiasCurrentMeasPortnread-onlycurrentLine Optical Module Laser Bias :This OID gives the bias value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Bias = A…
1.3.6.1.4.1.20044.26.3.3.211Tablepm1005Mesrxfp1LoTxPowerMeasTablenot-accessiblecurrentList of pm1005Mesrxfp1LoTxPowerMeas Article
1.3.6.1.4.1.20044.26.3.3.211.1Rowpm1005Mesrxfp1LoTxPowerMeasEntrynot-accessiblecurrentRow definition for the pm1005Mesrxfp1LoTxPowerMeas table
1.3.6.1.4.1.20044.26.3.3.211.1.1Columnpm1005Mesrxfp1LoTxPowerMeasIndexread-onlycurrentIndex definition for the pm1005Mesrxfp1LoTxPowerMeas table
1.3.6.1.4.1.20044.26.3.3.211.1.2Columnpm1005Mesrxfp1LoTxPowerMeasPortnread-onlycurrentLine Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (…
1.3.6.1.4.1.20044.26.3.3.212Tablepm1005Mesrxfp1LiRxPowerMeasTablenot-accessiblecurrentList of pm1005Mesrxfp1LiRxPowerMeas Article
1.3.6.1.4.1.20044.26.3.3.212.1Rowpm1005Mesrxfp1LiRxPowerMeasEntrynot-accessiblecurrentRow definition for the pm1005Mesrxfp1LiRxPowerMeas table
1.3.6.1.4.1.20044.26.3.3.212.1.1Columnpm1005Mesrxfp1LiRxPowerMeasIndexread-onlycurrentIndex definition for the pm1005Mesrxfp1LiRxPowerMeas table
1.3.6.1.4.1.20044.26.3.3.212.1.2Columnpm1005Mesrxfp1LiRxPowerMeasPortnread-onlycurrentLine Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (P…
1.3.6.1.4.1.20044.26.3.3.213Tablepm1005Mesrxfp1LxAux1MeasTablenot-accessibledeprecatedList of pm1005Mesrxfp1LxAux1Meas Article
1.3.6.1.4.1.20044.26.3.3.213.1Rowpm1005Mesrxfp1LxAux1MeasEntrynot-accessibledeprecatedRow definition for the pm1005Mesrxfp1LxAux1Meas table
1.3.6.1.4.1.20044.26.3.3.213.1.1Columnpm1005Mesrxfp1LxAux1MeasIndexread-onlydeprecatedIndex definition for the pm1005Mesrxfp1LxAux1Meas table
1.3.6.1.4.1.20044.26.3.3.213.1.2Columnpm1005Mesrxfp1LxAux1MeasPortnread-onlydeprecatedNot Used :This OID gives the receive power value read in the DDM (Digital Diagnostic Monitoring) of the XFP or OTX plugged in line #n (Unit = ?)
1.3.6.1.4.1.20044.26.3.3.214Tablepm1005Mesrxfp1LxAux2MeasTablenot-accessibledeprecatedList of pm1005Mesrxfp1LxAux2Meas Article
1.3.6.1.4.1.20044.26.3.3.214.1Rowpm1005Mesrxfp1LxAux2MeasEntrynot-accessibledeprecatedRow definition for the pm1005Mesrxfp1LxAux2Meas table
1.3.6.1.4.1.20044.26.3.3.214.1.1Columnpm1005Mesrxfp1LxAux2MeasIndexread-onlydeprecatedIndex definition for the pm1005Mesrxfp1LxAux2Meas table
1.3.6.1.4.1.20044.26.3.3.214.1.2Columnpm1005Mesrxfp1LxAux2MeasPortnread-onlydeprecatedNot Used :This OID gives the receive power value read in the DDM (Digital Diagnostic Monitoring) of the XFP or OTX plugged in line #n (Unit = ?)
1.3.6.1.4.1.20044.26.3.3.224Tablepm1005Mesrotx1AgingTablenot-accessiblecurrentList of pm1005Mesrotx1Aging Article
1.3.6.1.4.1.20044.26.3.3.224.1Rowpm1005Mesrotx1AgingEntrynot-accessiblecurrentRow definition for the pm1005Mesrotx1Aging table
1.3.6.1.4.1.20044.26.3.3.224.1.1Columnpm1005Mesrotx1AgingIndexread-onlycurrentIndex definition for the pm1005Mesrotx1Aging table
1.3.6.1.4.1.20044.26.3.3.224.1.2Columnpm1005Mesrotx1AgingPortnread-onlycurrentLine OTX TLH Aging :This OID gives the aging of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Unit = %) <Help> This measure gives the ag…
1.3.6.1.4.1.20044.26.3.3.225Tablepm1005Mesrotx1LaserTemperatureTablenot-accessibledeprecatedList of pm1005Mesrotx1LaserTemperature Article
1.3.6.1.4.1.20044.26.3.3.225.1Rowpm1005Mesrotx1LaserTemperatureEntrynot-accessibledeprecatedRow definition for the pm1005Mesrotx1LaserTemperature table
1.3.6.1.4.1.20044.26.3.3.225.1.1Columnpm1005Mesrotx1LaserTemperatureIndexread-onlydeprecatedIndex definition for the pm1005Mesrotx1LaserTemperature table
1.3.6.1.4.1.20044.26.3.3.225.1.2Columnpm1005Mesrotx1LaserTemperaturePortnread-onlydeprecatedLine OTX TLH Laser Temperature :This OID gives the laser temperature of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Unit = C) <Help> T…
1.3.6.1.4.1.20044.26.3.3.226Tablepm1005Mesrotx1FreqDeviationTablenot-accessiblecurrentList of pm1005Mesrotx1FreqDeviation Article
1.3.6.1.4.1.20044.26.3.3.226.1Rowpm1005Mesrotx1FreqDeviationEntrynot-accessiblecurrentRow definition for the pm1005Mesrotx1FreqDeviation table
1.3.6.1.4.1.20044.26.3.3.226.1.1Columnpm1005Mesrotx1FreqDeviationIndexread-onlycurrentIndex definition for the pm1005Mesrotx1FreqDeviation table
1.3.6.1.4.1.20044.26.3.3.226.1.2Columnpm1005Mesrotx1FreqDeviationPortnread-onlycurrentLine OTX TLH Frequency Deviation :This OID gives the frequency deviation of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Unit = MHz) <H…
1.3.6.1.4.1.20044.26.3.3.227Tablepm1005Mesrotx1LaserWvlengthTablenot-accessiblecurrentList of pm1005Mesrotx1LaserWvlength Article
1.3.6.1.4.1.20044.26.3.3.227.1Rowpm1005Mesrotx1LaserWvlengthEntrynot-accessiblecurrentRow definition for the pm1005Mesrotx1LaserWvlength table
1.3.6.1.4.1.20044.26.3.3.227.1.1Columnpm1005Mesrotx1LaserWvlengthIndexread-onlycurrentIndex definition for the pm1005Mesrotx1LaserWvlength table
1.3.6.1.4.1.20044.26.3.3.227.1.2Columnpm1005Mesrotx1LaserWvlengthPortnread-onlycurrentLine Optical Module Wavelength :This OID gives the laser wavelength of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Unit = nm) <Help> T…
1.3.6.1.4.1.20044.26.4Nodepm1005counters
1.3.6.1.4.1.20044.26.4.1Nodepm1005CntOther
1.3.6.1.4.1.20044.26.4.2Nodepm1005CntClient
1.3.6.1.4.1.20044.26.4.2.16Tablepm1005CntupRaRemCntTablenot-accessiblecurrentList of pm1005CntupRaRemCnt Article
1.3.6.1.4.1.20044.26.4.2.16.1Rowpm1005CntupRaRemCntEntrynot-accessiblecurrentRow definition for the pm1005CntupRaRemCnt table
1.3.6.1.4.1.20044.26.4.2.16.1.1Columnpm1005CntupRaRemCntIndexread-onlycurrentIndex definition for the pm1005CntupRaRemCnt table
1.3.6.1.4.1.20044.26.4.2.16.1.2Columnpm1005CntupRaRemCntValuePortnread-onlycurrentClient Rate Adapt. Words Removal :This counter is incremented each time a rate adaptation 10B word is removed from the Client input stream
1.3.6.1.4.1.20044.26.4.2.16.1.3Columnpm1005CntupRaRemCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the rate adaptation removal counter value is invalid on Port
1.3.6.1.4.1.20044.26.4.2.16.1.4Columnpm1005CntupRaRemCntOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a rate adaptation removal counter overload on Port
1.3.6.1.4.1.20044.26.4.2.24Tablepm1005CntupRaInsCntTablenot-accessiblecurrentList of pm1005CntupRaInsCnt Article
1.3.6.1.4.1.20044.26.4.2.24.1Rowpm1005CntupRaInsCntEntrynot-accessiblecurrentRow definition for the pm1005CntupRaInsCnt table
1.3.6.1.4.1.20044.26.4.2.24.1.1Columnpm1005CntupRaInsCntIndexread-onlycurrentIndex definition for the pm1005CntupRaInsCnt table
1.3.6.1.4.1.20044.26.4.2.24.1.2Columnpm1005CntupRaInsCntValuePortnread-onlycurrentClient Rate Adapt. Words Insertion :This counter is incremented each time a rate adaptation 10B word is inserted in the Client input stream
1.3.6.1.4.1.20044.26.4.2.24.1.3Columnpm1005CntupRaInsCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the rate adaptation insertion counter value is invalid on Port
1.3.6.1.4.1.20044.26.4.2.24.1.4Columnpm1005CntupRaInsCntOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a rate adaptation insertion counter overload on Port
1.3.6.1.4.1.20044.26.4.2.32Tablepm1005CntupRdErrCntTablenot-accessiblecurrentList of pm1005CntupRdErrCnt Article
1.3.6.1.4.1.20044.26.4.2.32.1Rowpm1005CntupRdErrCntEntrynot-accessiblecurrentRow definition for the pm1005CntupRdErrCnt table
1.3.6.1.4.1.20044.26.4.2.32.1.1Columnpm1005CntupRdErrCntIndexread-onlycurrentIndex definition for the pm1005CntupRdErrCnt table
1.3.6.1.4.1.20044.26.4.2.32.1.2Columnpm1005CntupRdErrCntValuePortnread-onlycurrentClient Input Errors :This counter is increased each time a 10b/8b running disparity error is detected on the Client input stream <Help> This counter gives the …
1.3.6.1.4.1.20044.26.4.2.32.1.3Columnpm1005CntupRdErrCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the client error counter value is invalid on Port
1.3.6.1.4.1.20044.26.4.2.32.1.4Columnpm1005CntupRdErrCntOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a client input error counter overload on Port
1.3.6.1.4.1.20044.26.4.2.40Tablepm1005CntupTimCntTablenot-accessiblecurrentList of pm1005CntupTimCnt Article
1.3.6.1.4.1.20044.26.4.2.40.1Rowpm1005CntupTimCntEntrynot-accessiblecurrentRow definition for the pm1005CntupTimCnt table
1.3.6.1.4.1.20044.26.4.2.40.1.1Columnpm1005CntupTimCntIndexread-onlycurrentIndex definition for the pm1005CntupTimCnt table
1.3.6.1.4.1.20044.26.4.2.40.1.2Columnpm1005CntupTimCntValuePortnread-onlycurrentClient Upstream Timer Counter :This is the timing counter dedicated to the upstream access counters. It is incremented every 125 us.
1.3.6.1.4.1.20044.26.4.2.40.1.3Columnpm1005CntupTimCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the upstream timing counter value is invalid on Port
1.3.6.1.4.1.20044.26.4.2.40.1.4Columnpm1005CntupTimCntOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a upstream timing counter overload on Port
1.3.6.1.4.1.20044.26.4.2.48Tablepm1005CntupCvErrCntTablenot-accessiblecurrentList of pm1005CntupCvErrCnt Article
1.3.6.1.4.1.20044.26.4.2.48.1Rowpm1005CntupCvErrCntEntrynot-accessiblecurrentRow definition for the pm1005CntupCvErrCnt table
1.3.6.1.4.1.20044.26.4.2.48.1.1Columnpm1005CntupCvErrCntIndexread-onlycurrentIndex definition for the pm1005CntupCvErrCnt table
1.3.6.1.4.1.20044.26.4.2.48.1.2Columnpm1005CntupCvErrCntValuePortnread-onlycurrentClient Coding Violation Counter :This counter is increased each time a 10b/8b coding violation is detected on the Client input stream
1.3.6.1.4.1.20044.26.4.2.48.1.3Columnpm1005CntupCvErrCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the coding violation counter value is invalid on Port
1.3.6.1.4.1.20044.26.4.2.48.1.4Columnpm1005CntupCvErrCntOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a coding violation counter overload on Port
1.3.6.1.4.1.20044.26.4.2.64Tablepm1005CntdwCbipCntTablenot-accessiblecurrentList of pm1005CntdwCbipCnt Article
1.3.6.1.4.1.20044.26.4.2.64.1Rowpm1005CntdwCbipCntEntrynot-accessiblecurrentRow definition for the pm1005CntdwCbipCnt table
1.3.6.1.4.1.20044.26.4.2.64.1.1Columnpm1005CntdwCbipCntIndexread-onlycurrentIndex definition for the pm1005CntdwCbipCnt table
1.3.6.1.4.1.20044.26.4.2.64.1.2Columnpm1005CntdwCbipCntValuePortnread-onlycurrentClient Output Errors :This counter is incremented each time a CBIP parity error is detected on the Client output stream <Help> This counter gives the number of…
1.3.6.1.4.1.20044.26.4.2.64.1.3Columnpm1005CntdwCbipCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the CBIP error counter value is invalid on Port
1.3.6.1.4.1.20044.26.4.2.64.1.4Columnpm1005CntdwCbipCntOverloadPortnread-onlycurrentClient CBIP Counter Overload :This OID when set indicates a CBIP error counter overload on Port
1.3.6.1.4.1.20044.26.4.2.72Tablepm1005CntdwTimCntTablenot-accessiblecurrentList of pm1005CntdwTimCnt Article
1.3.6.1.4.1.20044.26.4.2.72.1Rowpm1005CntdwTimCntEntrynot-accessiblecurrentRow definition for the pm1005CntdwTimCnt table
1.3.6.1.4.1.20044.26.4.2.72.1.1Columnpm1005CntdwTimCntIndexread-onlycurrentIndex definition for the pm1005CntdwTimCnt table
1.3.6.1.4.1.20044.26.4.2.72.1.2Columnpm1005CntdwTimCntValuePortnread-onlycurrentClient Downstream Timer Counter :This is the timing counter dedicated to the downstream access counters. It is incremented every 125 us.
1.3.6.1.4.1.20044.26.4.2.72.1.3Columnpm1005CntdwTimCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the downstream timer counter value is invalid on Port
1.3.6.1.4.1.20044.26.4.2.72.1.4Columnpm1005CntdwTimCntOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a downstream timer counter overload on Port
1.3.6.1.4.1.20044.26.4.3Nodepm1005CntLine
1.3.6.1.4.1.20044.26.4.3.152Tablepm1005CntdfrmB1ErrCntTablenot-accessiblecurrentList of pm1005CntdfrmB1ErrCnt Article
1.3.6.1.4.1.20044.26.4.3.152.1Rowpm1005CntdfrmB1ErrCntEntrynot-accessiblecurrentRow definition for the pm1005CntdfrmB1ErrCnt table
1.3.6.1.4.1.20044.26.4.3.152.1.1Columnpm1005CntdfrmB1ErrCntIndexread-onlycurrentIndex definition for the pm1005CntdfrmB1ErrCnt table
1.3.6.1.4.1.20044.26.4.3.152.1.2Columnpm1005CntdfrmB1ErrCntValuePortnread-onlycurrentLine Input B1 Errors :This counter is incremented each time a B1 error is detected on the Deframer input stream. <Help> This counter gives the number of B1 err…
1.3.6.1.4.1.20044.26.4.3.152.1.3Columnpm1005CntdfrmB1ErrCntErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the B1 error counter value is invalid on Port
1.3.6.1.4.1.20044.26.4.3.152.1.4Columnpm1005CntdfrmB1ErrCntOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a B1 error counter overload on Port
1.3.6.1.4.1.20044.26.4.3.153Tablepm1005CntdfrmTimCntTablenot-accessiblecurrentList of pm1005CntdfrmTimCnt Article
1.3.6.1.4.1.20044.26.4.3.153.1Rowpm1005CntdfrmTimCntEntrynot-accessiblecurrentRow definition for the pm1005CntdfrmTimCnt table
1.3.6.1.4.1.20044.26.4.3.153.1.1Columnpm1005CntdfrmTimCntIndexread-onlycurrentIndex definition for the pm1005CntdfrmTimCnt table
1.3.6.1.4.1.20044.26.4.3.153.1.2Columnpm1005CntdfrmTimCntValuePortnread-onlycurrentLine Timer Counter :This is the timing counter dedicated to the downstream deframer counters. It is incremented every 125 us.
1.3.6.1.4.1.20044.26.4.3.153.1.3Columnpm1005CntdfrmTimCntErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.26.4.3.153.1.4Columnpm1005CntdfrmTimCntOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.26.4.3.154Tablepm1005CntdfrmPrimLineErrCntTablenot-accessiblecurrentList of pm1005CntdfrmPrimLineErrCnt Article
1.3.6.1.4.1.20044.26.4.3.154.1Rowpm1005CntdfrmPrimLineErrCntEntrynot-accessiblecurrentRow definition for the pm1005CntdfrmPrimLineErrCnt table
1.3.6.1.4.1.20044.26.4.3.154.1.1Columnpm1005CntdfrmPrimLineErrCntIndexread-onlycurrentIndex definition for the pm1005CntdfrmPrimLineErrCnt table
1.3.6.1.4.1.20044.26.4.3.154.1.2Columnpm1005CntdfrmPrimLineErrCntValuePortnread-onlycurrentLine Input FEC Corrected Errors :This counter is incremented each time the FEC is correcting an error on the line input stream. <Help> This counter gives the n…
1.3.6.1.4.1.20044.26.4.3.154.1.3Columnpm1005CntdfrmPrimLineErrCntErrorPortnread-onlycurrentFEC Counter Error :This bit when set indicates the FEC corrected errors counter value is invalid on Line
1.3.6.1.4.1.20044.26.4.3.154.1.4Columnpm1005CntdfrmPrimLineErrCntOverloadPortnread-onlycurrentFEC Counter Overload :This bit when set indicates a FEC corrected errors counter overload on Line
1.3.6.1.4.1.20044.26.4.259Scalarpm1005CntCountersResetread-writecurrentCounters Reset:This OID resets and restarts all the counters
1.3.6.1.4.1.20044.26.4.260Scalarpm1005CntCountersStopread-writecurrentCounters stop:This OID stops all the counters
1.3.6.1.4.1.20044.26.6Nodepm1005controlsWrite
1.3.6.1.4.1.20044.26.6.1Nodepm1005CtrlOther
1.3.6.1.4.1.20044.26.6.1.1Nodepm1005CtrlconfMgnt1
1.3.6.1.4.1.20044.26.6.1.1.1Scalarpm1005CtrlConf1Load1read-writecurrentLoad Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM.
1.3.6.1.4.1.20044.26.6.1.1.2Scalarpm1005CtrlConf2Load1read-writecurrentLoad Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM.
1.3.6.1.4.1.20044.26.6.1.1.10Scalarpm1005CtrlConf2Flash1read-writecurrentWrite Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura…
1.3.6.1.4.1.20044.26.6.1.1.14Scalarpm1005CtrlConf2Clear1read-writecurrentClear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o…
1.3.6.1.4.1.20044.26.6.1.4Nodepm1005Ctrlsynth4
1.3.6.1.4.1.20044.26.6.1.4.1Scalarpm1005CtrlCorrelatOnread-writecurrentEnable Alarm Correlation :This OID enables the alarm correlation in the PM.
1.3.6.1.4.1.20044.26.6.1.4.2Scalarpm1005CtrlCorrelatOffread-writecurrentDisable Alarm Correlation :This OID disables the alarm correlation in the PM.
1.3.6.1.4.1.20044.26.6.1.5Nodepm1005CtrlswMgnt
1.3.6.1.4.1.20044.26.6.1.5.2Scalarpm1005CtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> …
1.3.6.1.4.1.20044.26.6.1.5.3Scalarpm1005CtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th…
1.3.6.1.4.1.20044.26.6.1.5.5Scalarpm1005CtrlLoadSwBank1read-writecurrentSet Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW…
1.3.6.1.4.1.20044.26.6.1.5.6Scalarpm1005CtrlLoadSwBank2read-writecurrentSet Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S…
1.3.6.1.4.1.20044.26.6.1.6Nodepm1005CtrlgwMgnt
1.3.6.1.4.1.20044.26.6.1.6.1Scalarpm1005CtrlCurrentGwResetread-writecurrentActive Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting.
1.3.6.1.4.1.20044.26.6.1.6.5Scalarpm1005CtrlLoadGwBank1read-writecurrentSet Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.26.6.1.6.6Scalarpm1005CtrlLoadGwBank2read-writecurrentSet Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.26.6.1.6.7Scalarpm1005CtrlLoadGwBank3read-writecurrentSet Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.26.6.1.6.8Scalarpm1005CtrlLoadGwBank4read-writecurrentSet Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.26.6.1.192Nodepm1005CtrlledTest
1.3.6.1.4.1.20044.26.6.1.192.1Scalarpm1005CtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.26.6.1.192.2Scalarpm1005CtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.26.6.1.192.3Scalarpm1005CtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.26.6.1.193Nodepm1005CtrlmoduleOosMode
1.3.6.1.4.1.20044.26.6.1.193.1Scalarpm1005CtrlModuleOosModeread-writecurrentPM Out Of Service :This OID sets the PM Out Of Service <Help> This control defines the service state of the complete module
1.3.6.1.4.1.20044.26.6.1.197Nodepm1005CtrlmaintenanceMode
1.3.6.1.4.1.20044.26.6.1.197.1Scalarpm1005CtrlMaintenanceModeread-writecurrentModule Maintenance Mode :This OID enables the maintenance mode on the PM. <Help> This control enables the maintenance mode on the PM.
1.3.6.1.4.1.20044.26.6.1.198Nodepm1005CtrldccEnable
1.3.6.1.4.1.20044.26.6.1.198.1Scalarpm1005CtrlDccEnableread-writecurrentDCC Enable :This OID enables the DCC mode on the PM <Help> This control enables the DCC mode on the PM
1.3.6.1.4.1.20044.26.6.2Nodepm1005CtrlClient
1.3.6.1.4.1.20044.26.6.2.16Tablepm1005CtrlaccessLoopTablenot-accessiblecurrentList of pm1005CtrlaccessLoop Article
1.3.6.1.4.1.20044.26.6.2.16.1Rowpm1005CtrlaccessLoopEntrynot-accessiblecurrentRow definition for the pm1005CtrlaccessLoop table
1.3.6.1.4.1.20044.26.6.2.16.1.1Columnpm1005CtrlaccessLoopIndexread-onlycurrentIndex definition for the pm1005CtrlaccessLoop table
1.3.6.1.4.1.20044.26.6.2.16.1.2Columnpm1005CtrlaccessLoopPortnread-writecurrentClient Facility Loopback :This OID operates a Client Facility Loopback, looping client input signal on the client output port. The loop is located on the clien…
1.3.6.1.4.1.20044.26.6.2.18Tablepm1005CtrlportOosModeTablenot-accessiblecurrentList of pm1005CtrlportOosMode Article
1.3.6.1.4.1.20044.26.6.2.18.1Rowpm1005CtrlportOosModeEntrynot-accessiblecurrentRow definition for the pm1005CtrlportOosMode table
1.3.6.1.4.1.20044.26.6.2.18.1.1Columnpm1005CtrlportOosModeIndexread-onlycurrentIndex definition for the pm1005CtrlportOosMode table
1.3.6.1.4.1.20044.26.6.2.18.1.2Columnpm1005CtrlportOosModePortnread-writecurrentClient Port Out Of Service :This OID sets the client port Out Of Service <Help> This controls defines the service state of the client port
1.3.6.1.4.1.20044.26.6.2.19Tablepm1005CtrlsfpOnCtrlTablenot-accessiblecurrentList of pm1005CtrlsfpOnCtrl Article
1.3.6.1.4.1.20044.26.6.2.19.1Rowpm1005CtrlsfpOnCtrlEntrynot-accessiblecurrentRow definition for the pm1005CtrlsfpOnCtrl table
1.3.6.1.4.1.20044.26.6.2.19.1.1Columnpm1005CtrlsfpOnCtrlIndexread-onlycurrentIndex definition for the pm1005CtrlsfpOnCtrl table
1.3.6.1.4.1.20044.26.6.2.19.1.2Columnpm1005CtrlsfpOnCtrlPortnread-writecurrentClient SFP Optical Laser ON :This OID switches on the SFP.
1.3.6.1.4.1.20044.26.6.2.20Tablepm1005CtrlsfpOffCtrlTablenot-accessiblecurrentList of pm1005CtrlsfpOffCtrl Article
1.3.6.1.4.1.20044.26.6.2.20.1Rowpm1005CtrlsfpOffCtrlEntrynot-accessiblecurrentRow definition for the pm1005CtrlsfpOffCtrl table
1.3.6.1.4.1.20044.26.6.2.20.1.1Columnpm1005CtrlsfpOffCtrlIndexread-onlycurrentIndex definition for the pm1005CtrlsfpOffCtrl table
1.3.6.1.4.1.20044.26.6.2.20.1.2Columnpm1005CtrlsfpOffCtrlPortnread-writecurrentClient SFP Laser Shutdown :This OID switches off the SFP. <Help> This control defines the laser state of the client transceiver
1.3.6.1.4.1.20044.26.6.2.21Tablepm1005CtrlcsfUpInsTablenot-accessiblecurrentList of pm1005CtrlcsfUpIns Article
1.3.6.1.4.1.20044.26.6.2.21.1Rowpm1005CtrlcsfUpInsEntrynot-accessiblecurrentRow definition for the pm1005CtrlcsfUpIns table
1.3.6.1.4.1.20044.26.6.2.21.1.1Columnpm1005CtrlcsfUpInsIndexread-onlycurrentIndex definition for the pm1005CtrlcsfUpIns table
1.3.6.1.4.1.20044.26.6.2.21.1.2Columnpm1005CtrlcsfUpInsPortnread-writecurrentClient Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo…
1.3.6.1.4.1.20044.26.6.2.22Tablepm1005CtrlcaisDwInsTablenot-accessiblecurrentList of pm1005CtrlcaisDwIns Article
1.3.6.1.4.1.20044.26.6.2.22.1Rowpm1005CtrlcaisDwInsEntrynot-accessiblecurrentRow definition for the pm1005CtrlcaisDwIns table
1.3.6.1.4.1.20044.26.6.2.22.1.1Columnpm1005CtrlcaisDwInsIndexread-onlycurrentIndex definition for the pm1005CtrlcaisDwIns table
1.3.6.1.4.1.20044.26.6.2.22.1.2Columnpm1005CtrlcaisDwInsPortnread-writecurrentClient AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port
1.3.6.1.4.1.20044.26.6.2.26Tablepm1005CtrlclientAccessTermLoopTablenot-accessiblecurrentList of pm1005CtrlclientAccessTermLoop Article
1.3.6.1.4.1.20044.26.6.2.26.1Rowpm1005CtrlclientAccessTermLoopEntrynot-accessiblecurrentRow definition for the pm1005CtrlclientAccessTermLoop table
1.3.6.1.4.1.20044.26.6.2.26.1.1Columnpm1005CtrlclientAccessTermLoopIndexread-onlycurrentIndex definition for the pm1005CtrlclientAccessTermLoop table
1.3.6.1.4.1.20044.26.6.2.26.1.2Columnpm1005CtrlclientAccessTermLoopPortnread-writecurrentClient Terminal Loopback :This OID operates a Client Terminal Loopback, looping client input signal on the client output port. The loop is located on the line …
1.3.6.1.4.1.20044.26.6.2.48Tablepm1005CtrlprotocolTablenot-accessiblecurrentList of pm1005Ctrlprotocol Article
1.3.6.1.4.1.20044.26.6.2.48.1Rowpm1005CtrlprotocolEntrynot-accessiblecurrentRow definition for the pm1005Ctrlprotocol table
1.3.6.1.4.1.20044.26.6.2.48.1.1Columnpm1005CtrlprotocolIndexread-onlycurrentIndex definition for the pm1005Ctrlprotocol table
1.3.6.1.4.1.20044.26.6.2.48.1.2Columnpm1005CtrlprotocolPortnread-writecurrentClient Protocol: This OID sets the protocol of the Client port.
1.3.6.1.4.1.20044.26.6.3Nodepm1005CtrlLine
1.3.6.1.4.1.20044.26.6.3.64Nodepm1005CtrlcommAccessLoop
1.3.6.1.4.1.20044.26.6.3.64.1Scalarpm1005CtrlCommAccessloopread-writedeprecatedPM Full Access Loop Mode :This OID, when set, puts the module in common access loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.
1.3.6.1.4.1.20044.26.6.3.66Nodepm1005CtrllineLoop
1.3.6.1.4.1.20044.26.6.3.66.1Scalarpm1005CtrlLineLoopread-writedeprecatedPM Line Loop Mode :This OID, when set at '1' puts the module in line loopback mode, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. The Ups…
1.3.6.1.4.1.20044.26.6.3.67Nodepm1005CtrlmsAis
1.3.6.1.4.1.20044.26.6.3.67.1Scalarpm1005CtrlMsAisread-writecurrentInsert MS-AIS/L-AIS On Line Output :This OID, when set, inserts an MS-AIS/L-AIS in the outgoing STM-64/OC-192 signal.
1.3.6.1.4.1.20044.26.6.3.69Tablepm1005CtrlfecDisableTablenot-accessiblecurrentList of pm1005CtrlfecDisable Article
1.3.6.1.4.1.20044.26.6.3.69.1Rowpm1005CtrlfecDisableEntrynot-accessiblecurrentRow definition for the pm1005CtrlfecDisable table
1.3.6.1.4.1.20044.26.6.3.69.1.1Columnpm1005CtrlfecDisableIndexread-onlycurrentIndex definition for the pm1005CtrlfecDisable table
1.3.6.1.4.1.20044.26.6.3.69.1.2Columnpm1005CtrlfecDisablePortnread-writecurrentForward Error Correction Inhibition :This OID, when set, inhibits the Forward Error Correction feature on the line input <Help> This control enables/disables t…
1.3.6.1.4.1.20044.26.6.3.73Nodepm1005CtrlProtMgnt
1.3.6.1.4.1.20044.26.6.3.73.1Scalarpm1005CtrlLineNumberread-writecurrentActive Line Number : This OID sets the active line number
1.3.6.1.4.1.20044.26.6.3.73.2Scalarpm1005CtrlProtModeread-writecurrentLine Switch Mode (Auto Or Manual) :This bit selects the manual (1) or automatic (0) switch method <Help> This control defines the protection switch mode on the…
1.3.6.1.4.1.20044.26.6.3.74Tablepm1005CtrllineOosModeTablenot-accessiblecurrentList of pm1005CtrllineOosMode Article
1.3.6.1.4.1.20044.26.6.3.74.1Rowpm1005CtrllineOosModeEntrynot-accessiblecurrentRow definition for the pm1005CtrllineOosMode table
1.3.6.1.4.1.20044.26.6.3.74.1.1Columnpm1005CtrllineOosModeIndexread-onlycurrentIndex definition for the pm1005CtrllineOosMode table
1.3.6.1.4.1.20044.26.6.3.74.1.2Columnpm1005CtrllineOosModePortnread-writecurrentLine Port Out Of Service :This OID sets the line port Out Of Service <Help> This control defines the service state of the line port
1.3.6.1.4.1.20044.26.6.3.208Tablepm1005CtrlxfpOnoffTablenot-accessiblecurrentList of pm1005CtrlxfpOnoff Article
1.3.6.1.4.1.20044.26.6.3.208.1Rowpm1005CtrlxfpOnoffEntrynot-accessiblecurrentRow definition for the pm1005CtrlxfpOnoff table
1.3.6.1.4.1.20044.26.6.3.208.1.1Columnpm1005CtrlxfpOnoffIndexread-onlycurrentIndex definition for the pm1005CtrlxfpOnoff table
1.3.6.1.4.1.20044.26.6.3.208.1.2Columnpm1005CtrlxfpOnoffPortnread-writecurrentLine Optical Laser Shutdown :This OID switches off the XFP or the OTX <Help> This control defines the laser state of the line transceiver
1.3.6.1.4.1.20044.26.6.3.209Tablepm1005CtrlxfpLineLoopTablenot-accessiblecurrentList of pm1005CtrlxfpLineLoop Article
1.3.6.1.4.1.20044.26.6.3.209.1Rowpm1005CtrlxfpLineLoopEntrynot-accessiblecurrentRow definition for the pm1005CtrlxfpLineLoop table
1.3.6.1.4.1.20044.26.6.3.209.1.1Columnpm1005CtrlxfpLineLoopIndexread-onlycurrentIndex definition for the pm1005CtrlxfpLineLoop table
1.3.6.1.4.1.20044.26.6.3.209.1.2Columnpm1005CtrlxfpLineLoopPortnread-writecurrentLine Facility Loopback :This OID operates a Line Facility Loopback, looping line input signal on the line output port. The loop is located on the line transcei…
1.3.6.1.4.1.20044.26.6.3.210Tablepm1005CtrlxfpXfiLoopTablenot-accessiblecurrentList of pm1005CtrlxfpXfiLoop Article
1.3.6.1.4.1.20044.26.6.3.210.1Rowpm1005CtrlxfpXfiLoopEntrynot-accessiblecurrentRow definition for the pm1005CtrlxfpXfiLoop table
1.3.6.1.4.1.20044.26.6.3.210.1.1Columnpm1005CtrlxfpXfiLoopIndexread-onlycurrentIndex definition for the pm1005CtrlxfpXfiLoop table
1.3.6.1.4.1.20044.26.6.3.210.1.2Columnpm1005CtrlxfpXfiLoopPortnread-writecurrentLine Terminal Loopback :This OID operates a Line Terminal Loopback, looping line input signal on the line output port. The loop is located on all client transc…
1.3.6.1.4.1.20044.26.6.3.212Tablepm1005CtrllineTunableChannelTablenot-accessiblecurrentList of pm1005CtrllineTunableChannel Article
1.3.6.1.4.1.20044.26.6.3.212.1Rowpm1005CtrllineTunableChannelEntrynot-accessiblecurrentRow definition for the pm1005CtrllineTunableChannel table
1.3.6.1.4.1.20044.26.6.3.212.1.1Columnpm1005CtrllineTunableChannelIndexread-onlycurrentIndex definition for the pm1005CtrllineTunableChannel table
1.3.6.1.4.1.20044.26.6.3.212.1.2Columnpm1005CtrllineTunableChannelPortnread-writecurrentITU Channel :This OID selects the ITU channel of the Line OTX TLH Laser <Help> This control defines the ITU channel of the Line OTX TLH Laser
1.3.6.1.4.1.20044.26.6.3.213Tablepm1005CtrllinePhotodiodeModeTablenot-accessiblecurrentList of pm1005CtrllinePhotodiodeMode Article
1.3.6.1.4.1.20044.26.6.3.213.1Rowpm1005CtrllinePhotodiodeModeEntrynot-accessiblecurrentRow definition for the pm1005CtrllinePhotodiodeMode table
1.3.6.1.4.1.20044.26.6.3.213.1.1Columnpm1005CtrllinePhotodiodeModeIndexread-onlycurrentIndex definition for the pm1005CtrllinePhotodiodeMode table
1.3.6.1.4.1.20044.26.6.3.213.1.2Columnpm1005CtrllinePhotodiodeModePortnread-writecurrentOTX TLH Rx Sens. Mode :This OID defines the Rx sensiblity mode of the Line OTX TLH <Help> This control defines the receiver sensibility mode of the Line OTX TL…
1.3.6.1.4.1.20044.26.6.3.214Tablepm1005CtrllinePhotodiodeValueTablenot-accessiblecurrentList of pm1005CtrllinePhotodiodeValue Article
1.3.6.1.4.1.20044.26.6.3.214.1Rowpm1005CtrllinePhotodiodeValueEntrynot-accessiblecurrentRow definition for the pm1005CtrllinePhotodiodeValue table
1.3.6.1.4.1.20044.26.6.3.214.1.1Columnpm1005CtrllinePhotodiodeValueIndexread-onlycurrentIndex definition for the pm1005CtrllinePhotodiodeValue table
1.3.6.1.4.1.20044.26.6.3.214.1.2Columnpm1005CtrllinePhotodiodeValuePortnread-writecurrentOTX TLH Rx Sensibility :This OID sets the Rx sensibility of the Line OTX TLH (custom mode only) <Help> This control defines the receiver sensibility value (onl…
1.3.6.1.4.1.20044.26.6.3.215Tablepm1005CtrllinePowerLaserTablenot-accessiblecurrentList of pm1005CtrllinePowerLaser Article
1.3.6.1.4.1.20044.26.6.3.215.1Rowpm1005CtrllinePowerLaserEntrynot-accessiblecurrentRow definition for the pm1005CtrllinePowerLaser table
1.3.6.1.4.1.20044.26.6.3.215.1.1Columnpm1005CtrllinePowerLaserIndexread-onlycurrentIndex definition for the pm1005CtrllinePowerLaser table
1.3.6.1.4.1.20044.26.6.3.215.1.2Columnpm1005CtrllinePowerLaserPortnread-writecurrentLine Laser Output Power [3-5] :This OID sets the output power value on the laser of the Line OTX TLH (AV=Power*10+158) (Unit = dBm) <Help> This control defines…
1.3.6.1.4.1.20044.26.7Nodepm1005ri
1.3.6.1.4.1.20044.26.7.1Nodepm1005riTable
1.3.6.1.4.1.20044.26.7.1.1Tablepm1005RinvSfpTablenot-accessiblecurrentList of the SFPs on the selected module
1.3.6.1.4.1.20044.26.7.1.1.1Rowpm1005RinvSfpEntrynot-accessiblecurrentRow definition for the SFP table
1.3.6.1.4.1.20044.26.7.1.1.1.1Columnpm1005RinvSfpIndexread-onlycurrentIndex for SFP table
1.3.6.1.4.1.20044.26.7.1.1.1.2Columnpm1005Rinvsfpread-onlycurrentInventory for the SFP: This OID contains the inventory for the SFP
1.3.6.1.4.1.20044.26.7.1.2Tablepm1005RinvLineTablenot-accessiblecurrentList of the XFPs on the selected module
1.3.6.1.4.1.20044.26.7.1.2.1Rowpm1005RinvLineEntrynot-accessiblecurrentRow definition for the XFP table
1.3.6.1.4.1.20044.26.7.1.2.1.1Columnpm1005RinvLineIndexread-onlycurrentIndex for XFP table
1.3.6.1.4.1.20044.26.7.1.2.1.2Columnpm1005RinvxfpLineread-onlycurrentInventory for the XFP: This OID contains the inventory for the XFP
1.3.6.1.4.1.20044.26.7.2Scalarpm1005RinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.26.7.3Scalarpm1005RinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.26.7.4Scalarpm1005RinvModulePlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.26.7.5Scalarpm1005RinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.26.7.6Scalarpm1005RinvGwPlatformread-onlycurrentGW platform desciption: This OID contains the description of the Gateware platform.
1.3.6.1.4.1.20044.26.8Nodepm1005download
1.3.6.1.4.1.20044.26.8.1Nodepm1005DwlOther
1.3.6.1.4.1.20044.26.8.1.0Nodepm1005DwlrestartProcess
1.3.6.1.4.1.20044.26.8.1.0.1Scalarpm1005DwlWarmRestartProcessedread-onlycurrentWarm Restart :This OID indicates that the module last restart was a Warm RESTART
1.3.6.1.4.1.20044.26.8.1.0.2Scalarpm1005DwlColdRestartProcessedread-onlycurrentCold Restart :This OID indicates that the module last restart was a Cold RESTART
1.3.6.1.4.1.20044.26.8.1.1Nodepm1005DwlswBanksUsed
1.3.6.1.4.1.20044.26.8.1.1.1Scalarpm1005DwlSwBank1Usedread-onlycurrentSW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby
1.3.6.1.4.1.20044.26.8.1.1.2Scalarpm1005DwlSwBank2Usedread-onlycurrentSW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby
1.3.6.1.4.1.20044.26.8.1.1.5Scalarpm1005DwlSwBank1Notemptyread-onlycurrentSW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package
1.3.6.1.4.1.20044.26.8.1.1.6Scalarpm1005DwlSwBank2Notemptyread-onlycurrentSW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package
1.3.6.1.4.1.20044.26.8.1.2Nodepm1005DwlgwBanksUsed
1.3.6.1.4.1.20044.26.8.1.2.1Scalarpm1005DwlGwBank1Usedread-onlycurrentGW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby
1.3.6.1.4.1.20044.26.8.1.2.2Scalarpm1005DwlGwBank2Usedread-onlycurrentGW bank 2 active :This OID indicates the module is working on GW bank 2
1.3.6.1.4.1.20044.26.8.1.2.3Scalarpm1005DwlGwBank3Usedread-onlycurrentGW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby
1.3.6.1.4.1.20044.26.8.1.2.4Scalarpm1005DwlGwBank4Usedread-onlycurrentGW bank 4 active :This OID indicates the module is working on GW bank 4
1.3.6.1.4.1.20044.26.8.1.2.5Scalarpm1005DwlGwBank1Notemptyread-onlycurrentGW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package
1.3.6.1.4.1.20044.26.8.1.2.6Scalarpm1005DwlGwBank2Notemptyread-onlycurrentGW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2
1.3.6.1.4.1.20044.26.8.1.2.7Scalarpm1005DwlGwBank3Notemptyread-onlycurrentGW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package
1.3.6.1.4.1.20044.26.8.1.2.8Scalarpm1005DwlGwBank4Notemptyread-onlycurrentGW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4
1.3.6.1.4.1.20044.26.8.2Nodepm1005DwlClient
1.3.6.1.4.1.20044.26.8.3Nodepm1005DwlLine
1.3.6.1.4.1.20044.26.9Nodepm1005Config
1.3.6.1.4.1.20044.26.9.1Nodepm1005CfgAccessCAisCsf
1.3.6.1.4.1.20044.26.9.1.1Tablepm1005CfgClientcaiscsfTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.26.9.1.1.1Rowpm1005CfgClientcaiscsfEntrynot-accessiblecurrentRow definition for the accessCAisCsf table
1.3.6.1.4.1.20044.26.9.1.1.1.1Columnpm1005CfgClientcaiscsfIndexread-onlycurrentIndex definition for the clientcaiscsf table
1.3.6.1.4.1.20044.26.9.1.1.1.3Columnpm1005CfgCAisModePortnread-writecurrentCAIS mode on Client Port :This register enables/disables port laser shutdown on CAIS insertion condition
1.3.6.1.4.1.20044.26.9.1.1.1.9Columnpm1005CfgUpAccessioAlmPortnread-writecurrentCSF contributors on Client Port :This register configures the contributors to upstream CSF insertion on the port.
1.3.6.1.4.1.20044.26.9.1.1.1.10Columnpm1005CfgUpMapperDeAlmPortnread-writecurrentCSF contributors on Client Port :This register configures the contributors to upstream CSF insertion on the port.
1.3.6.1.4.1.20044.26.9.1.1.1.17Columnpm1005CfgDownAccessioAlmPortnread-writecurrentCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port.
1.3.6.1.4.1.20044.26.9.1.1.1.18Columnpm1005CfgDownMapperDeAlmPortnread-writecurrentCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port.
1.3.6.1.4.1.20044.26.9.1.1.1.19Columnpm1005CfgDownDfrmAlmPortnread-writecurrentCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port.
1.3.6.1.4.1.20044.26.9.1.1.1.20Columnpm1005CfgDownLineSyncAlarmsPortnread-writedeprecatedCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port.
1.3.6.1.4.1.20044.26.9.2Nodepm1005CfgStartup
1.3.6.1.4.1.20044.26.9.2.1Tablepm1005CfgClientStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.26.9.2.1.1Rowpm1005CfgClientStartupEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.26.9.2.1.1.1Columnpm1005CfgClientStartupIndexread-onlycurrentIndex definition for the clientStartup table
1.3.6.1.4.1.20044.26.9.2.1.1.3Columnpm1005CfgSystConfPortPortnread-writecurrentDefault Settings on Client Port :This register configures the default initialisation settings on the port.
1.3.6.1.4.1.20044.26.9.2.1.1.4Columnpm1005CfgNetConfPortPortnread-writecurrentDefault Protocol on Client Port :This register configures the default initialisation protocol on the port.
1.3.6.1.4.1.20044.26.9.2.2Nodepm1005tablelineStartup
1.3.6.1.4.1.20044.26.9.2.2.2Scalarpm1005CfgsystConfLine1read-writecurrentDefault Settings on Line 1 :This register configures the default initialisation settings on Line port 1.
1.3.6.1.4.1.20044.26.9.2.2.5Scalarpm1005CfglineOptions1read-writecurrentDefault Options on Active Line Port :This register configures the default options on the active line port
1.3.6.1.4.1.20044.26.9.2.2.6Scalarpm1005CfgsystConfLine2read-writecurrentDefault Settings on Line 2 :This register configures the default initialisation settings on Line port 2.
1.3.6.1.4.1.20044.26.9.2.2.7Scalarpm1005CfglineSelectionread-writecurrentDefault Settings of active line :This register configures the start up active line.
1.3.6.1.4.1.20044.26.9.2.3Tablepm1005CfgXfpTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.26.9.2.3.1Rowpm1005CfgXfpEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.26.9.2.3.1.1Columnpm1005CfgXfpIndexread-onlycurrentIndex definition for the xfp table
1.3.6.1.4.1.20044.26.9.2.3.1.3Columnpm1005CfgSystConfXfpPortnread-writecurrentDefault settings on XFP Port :This register configures the default initialisation settings on XFP port.
1.3.6.1.4.1.20044.26.9.2.3.1.4Columnpm1005CfgDataRateConfXfpPortnread-writedeprecated:Reserved
1.3.6.1.4.1.20044.26.9.3Nodepm1005CfgLabels
1.3.6.1.4.1.20044.26.9.3.1Tablepm1005CfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.26.9.3.1.1Rowpm1005CfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.26.9.3.1.1.1Columnpm1005CfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.26.9.3.1.1.3Columnpm1005CfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.26.9.3.2Tablepm1005CfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.26.9.3.2.1Rowpm1005CfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.26.9.3.2.1.1Columnpm1005CfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.26.9.3.2.1.3Columnpm1005CfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.26.9.4Nodepm1005CfgStartuptlh
1.3.6.1.4.1.20044.26.9.4.1Tablepm1005CfgOtxtlhTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.26.9.4.1.1Rowpm1005CfgOtxtlhEntrynot-accessiblecurrentRow definition for the startuptlh table
1.3.6.1.4.1.20044.26.9.4.1.1.1Columnpm1005CfgOtxtlhIndexread-onlycurrentIndex definition for the otxtlh table
1.3.6.1.4.1.20044.26.9.4.1.1.3Columnpm1005CfgNuPortnread-writedeprecated:
1.3.6.1.4.1.20044.26.9.4.1.1.4Columnpm1005CfgLineDitherRatePortnread-writecurrentDefault Line OTX TLH FM amplitude :This register configures the start-up width of the frequency modulation of the Line OTX TLH
1.3.6.1.4.1.20044.26.9.4.1.1.5Columnpm1005CfgLineDitherFhzPortnread-writecurrentDefault Line OTX TLH FM frequency :This register configures the start-up frequency of the frequency modulation of the Line OTX TLH
1.3.6.1.4.1.20044.26.9.4.1.1.6Columnpm1005CfgLinePwrLaserPortnread-writecurrentDefaut Line OTX TLH output Power :This register configures the start-up output power of the Line OTX TLH (Unit = dBm)
1.3.6.1.4.1.20044.26.9.4.1.1.7Columnpm1005CfgLineFCurrentPortnread-writecurrentDefault Line OTX TLH Channel :This register configures the start-up laser channel of the Line OTX TLH
1.3.6.1.4.1.20044.26.9.4.1.1.8Columnpm1005CfgLineGridCurrentPortnread-writecurrentDefault Line OTX TLH Grid :This register configures the start-up laser grid of the Line OTX TLH
1.3.6.1.4.1.20044.26.9.4.1.1.9Columnpm1005CfgFPortnread-writecurrentDefault Line OTX TLH lowest Freq :This register configures the start-up lowest frequency supported on the Line OTX TLH
1.3.6.1.4.1.20044.26.9.4.1.1.10Columnpm1005CfgReservedPortnread-writedeprecated:
1.3.6.1.4.1.20044.26.9.4.1.1.11Columnpm1005CfgLinePhotodiodeModePortnread-writecurrentDefault Line OTX TLH APD mode :This register configures the start-up APD mode of the Line OTX TLH
1.3.6.1.4.1.20044.26.9.4.1.1.12Columnpm1005CfgLinePhotodiodeValuePortnread-writecurrentDefault Line OTX TLH APD atten. :This register configures the start-up APD attenuation on the Line OTX TLH
1.3.6.1.4.1.20044.26.9.5Nodepm1005CfgStartuptablefive
1.3.6.1.4.1.20044.26.9.5.1Tablepm1005CfgOtxtlhcapabilitiesTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.26.9.5.1.1Rowpm1005CfgOtxtlhcapabilitiesEntrynot-accessiblecurrentRow definition for the startuptablefive table
1.3.6.1.4.1.20044.26.9.5.1.1.1Columnpm1005CfgOtxtlhcapabilitiesIndexread-onlycurrentIndex definition for the otxtlhcapabilities table
1.3.6.1.4.1.20044.26.9.5.1.1.3Columnpm1005CfgComponentTypePortnread-onlycurrentComponent parameters :This OID defines the component parameters
1.3.6.1.4.1.20044.26.9.5.1.1.4Columnpm1005CfgMiscellaneousPortnread-onlycurrentMiscellaneous default settings :This OID defines the miscellaneous parameters
1.3.6.1.4.1.20044.26.9.5.1.1.5Columnpm1005CfgFirstChannelPortnread-onlycurrentNumber of the first channel of the component :This OID defines the first channel number of the PM
1.3.6.1.4.1.20044.26.9.5.1.1.6Columnpm1005CfgLastChannelPortnread-onlycurrentNumber of the last channel of the component :This OID defines the last channel number of the PM
1.3.6.1.4.1.20044.26.9.5.1.1.7Columnpm1005CfgGridPortnread-onlycurrentGrid value of the component :This OID defines the grid of the PM
1.3.6.1.4.1.20044.26.9.257Scalarpm1005CfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.26.10Nodepm1005traps
1.3.6.1.4.1.20044.26.10.2Scalarpm1005trapPortNumberread-onlycurrentLast port which generates a trap
1.3.6.1.4.1.20044.26.10.3Scalarpm1005trapLineNumberread-onlycurrentLast Line which generates a trap
1.3.6.1.4.1.20044.26.10.4Scalarpm1005trapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.26.10.30Notificationpm1005LineTrapNotUrgentGoesOncurrentNot urgent Line default is activated
1.3.6.1.4.1.20044.26.10.31Notificationpm1005LineTrapNotUrgentGoesOffcurrentNot urgent Line default disappeared
1.3.6.1.4.1.20044.26.10.32Notificationpm1005LineTrapUrgentGoesOncurrentUrgent Line default is activated
1.3.6.1.4.1.20044.26.10.33Notificationpm1005LineTrapUrgentGoesOffcurrentUrgent Line default disappeared
1.3.6.1.4.1.20044.26.10.34Notificationpm1005LineTrapCritGoesOncurrentCritical Line default is activated
1.3.6.1.4.1.20044.26.10.35Notificationpm1005LineTrapCritGoesOffcurrentCritical Line default disappeared
1.3.6.1.4.1.20044.26.10.40Notificationpm1005ClientTrapNotUrgentGoesOncurrentNot urgent client default is activated
1.3.6.1.4.1.20044.26.10.41Notificationpm1005ClientTrapNotUrgentGoesOffcurrentNot urgent client default disappeared
1.3.6.1.4.1.20044.26.10.42Notificationpm1005ClientTrapUrgentGoesOncurrentUrgent client default is activated
1.3.6.1.4.1.20044.26.10.43Notificationpm1005ClientTrapUrgentGoesOffcurrentUrgent client default disappeared
1.3.6.1.4.1.20044.26.10.44Notificationpm1005ClientTrapCritGoesOncurrentCritical client default is activated
1.3.6.1.4.1.20044.26.10.45Notificationpm1005ClientTrapCritGoesOffcurrentCritical client default disappeared
1.3.6.1.4.1.20044.26.10.50Notificationpm1005PowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.26.10.51Notificationpm1005PowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared
1.3.6.1.4.1.20044.26.11Nodepm1005Monitoring
1.3.6.1.4.1.20044.26.11.1Nodepm1005MonOther
1.3.6.1.4.1.20044.26.11.1.3Nodepm1005MonRmon
1.3.6.1.4.1.20044.26.11.1.3.359Scalarpm1005MonCountersResetread-writecurrentRMON Counters Reset:This OID resets and restarts all the RMON counters
1.3.6.1.4.1.20044.26.11.1.3.360Scalarpm1005MonCountersStopread-writecurrentRMON Counters stop:This OID stops all the RMON counters
1.3.6.1.4.1.20044.26.11.2Nodepm1005MonClient
1.3.6.1.4.1.20044.26.11.2.4Nodepm1005MonClientRmonCounter
1.3.6.1.4.1.20044.26.11.2.4.16Tablepm1005MonupRmonByteCntTablenot-accessiblecurrentList of pm1005MonupRmonByteCnt Article
1.3.6.1.4.1.20044.26.11.2.4.16.1Rowpm1005MonupRmonByteCntEntrynot-accessiblecurrentRow definition for the pm1005MonupRmonByteCnt table
1.3.6.1.4.1.20044.26.11.2.4.16.1.1Columnpm1005MonupRmonByteCntIndexread-onlycurrentIndex definition for the pm1005MonupRmonByteCnt table
1.3.6.1.4.1.20044.26.11.2.4.16.1.2Columnpm1005MonupRmonByteCntValuePortnread-onlycurrentClient Input Bytes :This counter is increased each time a data byte is received on the client port
1.3.6.1.4.1.20044.26.11.2.4.16.1.3Columnpm1005MonupRmonByteCntErrorPortnread-onlycurrentBytes Counter Error :This OID when set indicates the Bytes counter value is invalid on clinet port
1.3.6.1.4.1.20044.26.11.2.4.16.1.4Columnpm1005MonupRmonByteCntOverloadPortnread-onlycurrentBytes Counter Overload :This OID when set indicates a Bytes counter overload on client port
1.3.6.1.4.1.20044.26.11.2.4.24Tablepm1005MonupRmonCrcErrorCntTablenot-accessiblecurrentList of pm1005MonupRmonCrcErrorCnt Article
1.3.6.1.4.1.20044.26.11.2.4.24.1Rowpm1005MonupRmonCrcErrorCntEntrynot-accessiblecurrentRow definition for the pm1005MonupRmonCrcErrorCnt table
1.3.6.1.4.1.20044.26.11.2.4.24.1.1Columnpm1005MonupRmonCrcErrorCntIndexread-onlycurrentIndex definition for the pm1005MonupRmonCrcErrorCnt table
1.3.6.1.4.1.20044.26.11.2.4.24.1.2Columnpm1005MonupRmonCrcErrorCntValuePortnread-onlycurrentClient Input CRC Errors :This counter is increased each time a CRC error is detected on the client port
1.3.6.1.4.1.20044.26.11.2.4.24.1.3Columnpm1005MonupRmonCrcErrorCntErrorPortnread-onlycurrentCRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on clinet port
1.3.6.1.4.1.20044.26.11.2.4.24.1.4Columnpm1005MonupRmonCrcErrorCntOverloadPortnread-onlycurrentCRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on client port
1.3.6.1.4.1.20044.26.11.2.4.32Tablepm1005MonupRmonPacketsCntTablenot-accessiblecurrentList of pm1005MonupRmonPacketsCnt Article
1.3.6.1.4.1.20044.26.11.2.4.32.1Rowpm1005MonupRmonPacketsCntEntrynot-accessiblecurrentRow definition for the pm1005MonupRmonPacketsCnt table
1.3.6.1.4.1.20044.26.11.2.4.32.1.1Columnpm1005MonupRmonPacketsCntIndexread-onlycurrentIndex definition for the pm1005MonupRmonPacketsCnt table
1.3.6.1.4.1.20044.26.11.2.4.32.1.2Columnpm1005MonupRmonPacketsCntValuePortnread-onlycurrentClient Input Packets :This counter is increased each time a packet is received on the client port
1.3.6.1.4.1.20044.26.11.2.4.32.1.3Columnpm1005MonupRmonPacketsCntErrorPortnread-onlycurrentPackets Counter Error :This OID when set indicates the Packets counter value is invalid on clinet port
1.3.6.1.4.1.20044.26.11.2.4.32.1.4Columnpm1005MonupRmonPacketsCntOverloadPortnread-onlycurrentPackets Counter Overload :This OID when set indicates a Packets counter overload on client port
1.3.6.1.4.1.20044.26.11.2.4.40Tablepm1005MonupRmonBroadcastCntTablenot-accessiblecurrentList of pm1005MonupRmonBroadcastCnt Article
1.3.6.1.4.1.20044.26.11.2.4.40.1Rowpm1005MonupRmonBroadcastCntEntrynot-accessiblecurrentRow definition for the pm1005MonupRmonBroadcastCnt table
1.3.6.1.4.1.20044.26.11.2.4.40.1.1Columnpm1005MonupRmonBroadcastCntIndexread-onlycurrentIndex definition for the pm1005MonupRmonBroadcastCnt table
1.3.6.1.4.1.20044.26.11.2.4.40.1.2Columnpm1005MonupRmonBroadcastCntValuePortnread-onlycurrentClient Input Broadcast Packets :This counter is increased each time a broadcast packet is received on the client port
1.3.6.1.4.1.20044.26.11.2.4.40.1.3Columnpm1005MonupRmonBroadcastCntErrorPortnread-onlycurrentBroadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on clinet port
1.3.6.1.4.1.20044.26.11.2.4.40.1.4Columnpm1005MonupRmonBroadcastCntOverloadPortnread-onlycurrentBroadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port
1.3.6.1.4.1.20044.26.11.2.4.48Tablepm1005MonupRmonMulticastCntTablenot-accessiblecurrentList of pm1005MonupRmonMulticastCnt Article
1.3.6.1.4.1.20044.26.11.2.4.48.1Rowpm1005MonupRmonMulticastCntEntrynot-accessiblecurrentRow definition for the pm1005MonupRmonMulticastCnt table
1.3.6.1.4.1.20044.26.11.2.4.48.1.1Columnpm1005MonupRmonMulticastCntIndexread-onlycurrentIndex definition for the pm1005MonupRmonMulticastCnt table
1.3.6.1.4.1.20044.26.11.2.4.48.1.2Columnpm1005MonupRmonMulticastCntValuePortnread-onlycurrentClient Input Multicast Packets :This counter is increased each time a Multicast packet is received on the client port
1.3.6.1.4.1.20044.26.11.2.4.48.1.3Columnpm1005MonupRmonMulticastCntErrorPortnread-onlycurrentMulticast Counter Error :This OID when set indicates the Multicast counter value is invalid on clinet port
1.3.6.1.4.1.20044.26.11.2.4.48.1.4Columnpm1005MonupRmonMulticastCntOverloadPortnread-onlycurrentMulticast Counter Overload :This OID when set indicates a Multicast counter overload on client port
Type Definitions
NameSyntaxStatusDescription
Pm1005AdjustValueINTEGER { otxadjustvalue0(0), otxadjustvalue1(1), otxadjustvalue2(2), otxadjustvalue3(3), otxadjustvalue4(4), otxadjustvalue5(5), otxadjustvalue6(6), otxadjustvalue7(7), otxadjustvalue8(8), otxadjustvalue9(9), otxadjustvalue10(10) }currentDifferent values in Adjust mode on OTX-TLH on line ports
Pm1005OtxChannelINTEGERcurrentChannel selection on OTX-TLH on line ports
Pm1005OtxGridINTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50) }currentDifferent grids on OTX-TLH on line ports
Pm1005OtxModeINTEGER { otx80mode(1), otx60mode(2), otxadjustmode(4) }currentDifferent modes on OTX-TLH on line ports