EKINOPS-Pm1005-MIB
599 objects
MIB for managing Ekinops modules with PM1005 software
Imported Objects
| EKINOPS-MIB | EkiApiState EkiMeasureType EkiMode ekinops EkiOnOff EkiProtocol EkiState EkiSynchroMode |
| SNMPv2-SMI | Counter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20044.26 | IdentitymodulePm1005 | MIB for managing Ekinops modules with PM1005 software | ||
| 1.3.6.1.4.1.20044.26.2 | Nodepm1005alarms | |||
| 1.3.6.1.4.1.20044.26.2.1 | Nodepm1005AlmOther | |||
| 1.3.6.1.4.1.20044.26.2.1.1 | Nodepm1005AlmOtherNurg | |||
| 1.3.6.1.4.1.20044.26.2.1.1.2 | Nodepm1005AlmsynthAlm2 | |||
| 1.3.6.1.4.1.20044.26.2.1.1.2.1 | Scalarpm1005AlmConfTableSave | read-only | current | PM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> other… |
| 1.3.6.1.4.1.20044.26.2.1.1.2.2 | Scalarpm1005AlmInvUpload | read-only | current | Inventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> other (1) <Alarmtype> <Polarity> (2) |
| 1.3.6.1.4.1.20044.26.2.1.1.2.3 | Scalarpm1005AlmConfTableLoad | read-only | current | PM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> other (1) <Alarmt… |
| 1.3.6.1.4.1.20044.26.2.1.1.2.4 | Scalarpm1005AlmCorrelatOff | read-only | current | Not Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> other (1) <Alarmtype> <Polarity> (2) |
| 1.3.6.1.4.1.20044.26.2.1.1.2.5 | Scalarpm1005AlmMaintenanceOn | read-only | current | Maintenance Mode :This OID indicates that the PM is in maintenance mode. <Help> This alarm indicates that the maintenance mode is enabled on the PM <Condtype> … |
| 1.3.6.1.4.1.20044.26.2.1.2 | Nodepm1005AlmOtherUrg | |||
| 1.3.6.1.4.1.20044.26.2.1.2.194 | Nodepm1005AlmmodInitFailLevel2 | |||
| 1.3.6.1.4.1.20044.26.2.1.2.194.1 | Scalarpm1005AlmLedFail | read-only | current | Led Fail :This OID indicates that Led register has not been correctly initalized <Help> This alarm indicates if the module LEDs are correctly initialized <Cond… |
| 1.3.6.1.4.1.20044.26.2.1.2.194.2 | Scalarpm1005AlmNextColdBootForced | read-only | current | Next Cold Boot Forced :This OID indicates that the next Reset will be forced Cold <Help> This alarm indicates that the next reset of the module will be forced … |
| 1.3.6.1.4.1.20044.26.2.1.2.194.3 | Scalarpm1005AlmBootUndone | read-only | current | Boot Undone :This OID indicates that the boot has not been correctly achieved <Help> This alarm indicates if the module has correctly boot <Condtype> BOOT_UNDO… |
| 1.3.6.1.4.1.20044.26.2.1.2.194.4 | Scalarpm1005AlmResetHwInitFail | read-only | current | Reset HW Init Fail :This OID indicates that the HW intialization has caused unknown intial conditions <Help> This alarm indicates if the HW has been correctly … |
| 1.3.6.1.4.1.20044.26.2.1.2.194.5 | Scalarpm1005AlmSwInitFail | read-only | current | SW Init Fail :This OID indicates that the SW intialization has caused unknown intial conditions <Help> This alarm indicates if the SW module is correctly initi… |
| 1.3.6.1.4.1.20044.26.2.1.2.195 | Nodepm1005AlmmodInitFailLevel3 | |||
| 1.3.6.1.4.1.20044.26.2.1.2.195.1 | Scalarpm1005AlmGwIdentFail | read-only | current | GW Ident Fail :This OID indicates that GW identification has not been read <Help> This alarm indicates if the GW has been correctly identified <Condtype> GW_ID… |
| 1.3.6.1.4.1.20044.26.2.1.2.195.2 | Scalarpm1005AlmObmTypeReadFail | read-only | current | OBM Type Read Fail :This OID indicates that OBM type has not been recognized <Help> This alarm indicates if the OBM board has been correctly identified <Condty… |
| 1.3.6.1.4.1.20044.26.2.1.2.195.3 | Scalarpm1005AlmInitModuleFail | read-only | current | Init Module Fail :This OID indicates that the Module has not been correctly initialized <Help> This alarm indicates if the SW module is correctly initialized <… |
| 1.3.6.1.4.1.20044.26.2.1.2.195.5 | Scalarpm1005AlmXfp1InitFail | read-only | current | XFP1 Init Fail :This OID indicates that the XFP has not been correctly initialized <Help> This alarm indicates if the line transceiver 1 is correctly initializ… |
| 1.3.6.1.4.1.20044.26.2.1.2.195.6 | Scalarpm1005AlmXfp2InitFail | read-only | current | XFP2 Init Fail :This OID indicates that the XFP has not been correctly initialized <Help> This alarm indicates if the line transceiver 2 is correctly initializ… |
| 1.3.6.1.4.1.20044.26.2.1.2.195.7 | Scalarpm1005AlmLine1InitFail | read-only | current | Line1 Init Fail :This OID indicates that the Line registersvsubset has not been correctly initialized <Help> This alarm indicates if the line port 1 is correct… |
| 1.3.6.1.4.1.20044.26.2.1.2.195.8 | Scalarpm1005AlmLine2InitFail | read-only | current | Line2 Init Fail :This OID indicates that the Line register subset has not been correctly initialized <Help> This alarm indicates if the line port 2 is correctl… |
| 1.3.6.1.4.1.20044.26.2.1.2.195.9 | Scalarpm1005AlmClient1InitFail | read-only | current | Client1 Init Fail :This OID indicates that Client 1 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 1 is cor… |
| 1.3.6.1.4.1.20044.26.2.1.2.195.10 | Scalarpm1005AlmClient2InitFail | read-only | current | Client2 Init Fail :This OID indicates that Client 2 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 2 is cor… |
| 1.3.6.1.4.1.20044.26.2.1.2.195.11 | Scalarpm1005AlmClient3InitFail | read-only | current | Client3 Init Fail :This OID indicates that Client 3 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 3 is cor… |
| 1.3.6.1.4.1.20044.26.2.1.2.195.12 | Scalarpm1005AlmClient4InitFail | read-only | current | Client4 Init Fail :This OID indicates that Client 4 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 4 is cor… |
| 1.3.6.1.4.1.20044.26.2.1.2.195.13 | Scalarpm1005AlmClient5InitFail | read-only | current | Client5 Init Fail :This OID indicates that Client 5 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 5 is cor… |
| 1.3.6.1.4.1.20044.26.2.1.2.195.14 | Scalarpm1005AlmClient6InitFail | read-only | current | Client6 Init Fail :This OID indicates that Client 6 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 6 is cor… |
| 1.3.6.1.4.1.20044.26.2.1.2.195.15 | Scalarpm1005AlmClient7InitFail | read-only | current | Client7 Init Fail :This OID indicates that Client 7 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 7 is cor… |
| 1.3.6.1.4.1.20044.26.2.1.2.195.16 | Scalarpm1005AlmClient8InitFail | read-only | current | Client8 Init Fail :This OID indicates that Client 8 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 8 is cor… |
| 1.3.6.1.4.1.20044.26.2.1.3 | Nodepm1005AlmOtherCrit | |||
| 1.3.6.1.4.1.20044.26.2.1.3.0 | Nodepm1005AlmsynthAlm0 | |||
| 1.3.6.1.4.1.20044.26.2.1.3.0.9 | Scalarpm1005AlmModGlobFail | read-only | current | Module Failure :This OID is set on detection of a failure originating from the PM <Condtype> MOD_GLOB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> sy… |
| 1.3.6.1.4.1.20044.26.2.1.3.0.15 | Scalarpm1005AlmDefFuseA | read-only | current | Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.26.2.1.3.0.16 | Scalarpm1005AlmDefFuseB | read-only | current | Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.26.2.2 | Nodepm1005AlmClient | |||
| 1.3.6.1.4.1.20044.26.2.2.1 | Nodepm1005AlmClientNurg | |||
| 1.3.6.1.4.1.20044.26.2.2.1.48 | Tablepm1005AlmsfpWarnDdmTable | not-accessible | current | List of pm1005AlmsfpWarnDdm Article |
| 1.3.6.1.4.1.20044.26.2.2.1.48.1 | Rowpm1005AlmsfpWarnDdmEntry | not-accessible | current | Row definition for the pm1005AlmsfpWarnDdm table |
| 1.3.6.1.4.1.20044.26.2.2.1.48.1.1 | Columnpm1005AlmsfpWarnDdmIndex | read-only | current | Index definition for the pm1005AlmsfpWarnDdm table |
| 1.3.6.1.4.1.20044.26.2.2.1.48.1.2 | Columnpm1005AlmTxPwLowWngPortn | read-only | current | Client SFP Tx Power Low Warning :Warning indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> TX… |
| 1.3.6.1.4.1.20044.26.2.2.1.48.1.3 | Columnpm1005AlmTxPwrHighWngPortn | read-only | current | Client SFP Tx Power High Warning :Warning indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> … |
| 1.3.6.1.4.1.20044.26.2.2.1.48.1.4 | Columnpm1005AlmTxBiasLowWngPortn | read-only | current | Client SFP Bias Low Warning :Warning indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> … |
| 1.3.6.1.4.1.20044.26.2.2.1.48.1.5 | Columnpm1005AlmTxBiasHighWngPortn | read-only | current | Client SFP Bias High Warning :Warning indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype… |
| 1.3.6.1.4.1.20044.26.2.2.1.48.1.6 | Columnpm1005AlmVccLowWngPortn | read-only | current | Client SFP Power Supply Low Warning :Warning indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype… |
| 1.3.6.1.4.1.20044.26.2.2.1.48.1.7 | Columnpm1005AlmVccHighWngPortn | read-only | current | Client SFP Power Supply High Warning :Warning indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condty… |
| 1.3.6.1.4.1.20044.26.2.2.1.48.1.8 | Columnpm1005AlmTempLowWngPortn | read-only | current | Client SFP Temp Low Warning :Warning indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> TEMP_LO… |
| 1.3.6.1.4.1.20044.26.2.2.1.48.1.9 | Columnpm1005AlmTempHighWngPortn | read-only | current | Client SFP Temp High Warning :Warning indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> TEMP_… |
| 1.3.6.1.4.1.20044.26.2.2.1.48.1.16 | Columnpm1005AlmRxPwrLowWngPortn | read-only | current | Client SFP Rx Power Low Warning :Warning indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> RX_… |
| 1.3.6.1.4.1.20044.26.2.2.1.48.1.17 | Columnpm1005AlmRxPwrHighWngPortn | read-only | current | Client SFP Rx Power High Warning :Warning indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> R… |
| 1.3.6.1.4.1.20044.26.2.2.2 | Nodepm1005AlmClientUrg | |||
| 1.3.6.1.4.1.20044.26.2.2.2.32 | Tablepm1005AlmsfpAlmDdmTable | not-accessible | current | List of pm1005AlmsfpAlmDdm Article |
| 1.3.6.1.4.1.20044.26.2.2.2.32.1 | Rowpm1005AlmsfpAlmDdmEntry | not-accessible | current | Row definition for the pm1005AlmsfpAlmDdm table |
| 1.3.6.1.4.1.20044.26.2.2.2.32.1.1 | Columnpm1005AlmsfpAlmDdmIndex | read-only | current | Index definition for the pm1005AlmsfpAlmDdm table |
| 1.3.6.1.4.1.20044.26.2.2.2.32.1.2 | Columnpm1005AlmTxPwrLowAlaPortn | read-only | current | Client SFP Tx Power Low :Alarm indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> TX_PWR_LOW_A… |
| 1.3.6.1.4.1.20044.26.2.2.2.32.1.3 | Columnpm1005AlmTxPwrHighAlaPortn | read-only | current | Client SFP Tx Power High :Alarm indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> TX_PWR_HIG… |
| 1.3.6.1.4.1.20044.26.2.2.2.32.1.4 | Columnpm1005AlmTxBiasLowAlaPortn | read-only | current | Client SFP Bias Low :Alarm indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> TX_BIAS_LO… |
| 1.3.6.1.4.1.20044.26.2.2.2.32.1.5 | Columnpm1005AlmTxBiasHighAlaPortn | read-only | current | Client SFP Bias High :Alarm indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype> TX_BIAS_… |
| 1.3.6.1.4.1.20044.26.2.2.2.32.1.6 | Columnpm1005AlmVccLowAlaPortn | read-only | current | Client SFP Power Supply Low :Alarm indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype> VCC_LOW_… |
| 1.3.6.1.4.1.20044.26.2.2.2.32.1.7 | Columnpm1005AlmVccHighAlaPortn | read-only | current | Client SFP Power Supply High :Alarm indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condtype> VCC_HI… |
| 1.3.6.1.4.1.20044.26.2.2.2.32.1.8 | Columnpm1005AlmTempLowAlaPortn | read-only | current | Client SFP Temp Low :Alarm indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> TEMP_LOW_ALA_1 <P… |
| 1.3.6.1.4.1.20044.26.2.2.2.32.1.9 | Columnpm1005AlmTempHighAlaPortn | read-only | current | Client SFP Temp High :Alarm indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> TEMP_HIGH_ALA_1… |
| 1.3.6.1.4.1.20044.26.2.2.2.32.1.16 | Columnpm1005AlmRxPwrLowAlaPortn | read-only | current | Client SFP Rx Power Low :Alarm indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> RX_PWR_LOW_AL… |
| 1.3.6.1.4.1.20044.26.2.2.2.32.1.17 | Columnpm1005AlmRxPwrHighAlaPortn | read-only | current | Client SFP Rx Power High :Alarm indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> RX_PWR_HIGH… |
| 1.3.6.1.4.1.20044.26.2.2.3 | Nodepm1005AlmClientCrit | |||
| 1.3.6.1.4.1.20044.26.2.2.3.8 | Tablepm1005AlmsynthAlmPortTable | not-accessible | current | List of pm1005AlmsynthAlmPort Article |
| 1.3.6.1.4.1.20044.26.2.2.3.8.1 | Rowpm1005AlmsynthAlmPortEntry | not-accessible | current | Row definition for the pm1005AlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.26.2.2.3.8.1.1 | Columnpm1005AlmsynthAlmPortIndex | read-only | current | Index definition for the pm1005AlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.26.2.2.3.8.1.2 | Columnpm1005AlmSfpAbsentPortn | read-only | current | Client SFP Absent :This OID indicates that the SFP module is not present in the client port. <Help> This alarm indicates if the client transceiver is present. … |
| 1.3.6.1.4.1.20044.26.2.2.3.8.1.3 | Columnpm1005AlmDdmAbsentPortn | read-only | current | DDM Supported On Client SFP :This OID indicates that the Client SFP module supports the Digital Diagnostic Monitoring function <Help> This status indicates if … |
| 1.3.6.1.4.1.20044.26.2.2.3.8.1.5 | Columnpm1005AlmHwFailAccPortn | read-only | current | Client HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Condtype> HW_FAIL_ACC_1 <Probcause> equipmentMalfunction (16)… |
| 1.3.6.1.4.1.20044.26.2.2.3.8.1.6 | Columnpm1005AlmDwLsdPortn | read-only | current | Client SFP Laser Shutdown :This OID indicates the Client SFP transmitter output is ON. <Help> This status indicates if the client transceiver laser is ON or OF… |
| 1.3.6.1.4.1.20044.26.2.2.3.8.1.7 | Columnpm1005AlmClientLocalOosPortn | read-only | current | Local Client Port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local c… |
| 1.3.6.1.4.1.20044.26.2.2.3.8.1.8 | Columnpm1005AlmClientRemoteOosPortn | read-only | current | Remote Client Port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the remot… |
| 1.3.6.1.4.1.20044.26.2.2.3.8.1.9 | Columnpm1005AlmDwCaisPortn | read-only | current | Client AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indicates if a Client Alarm Indication Signal is… |
| 1.3.6.1.4.1.20044.26.2.2.3.8.1.10 | Columnpm1005AlmSfpDdmWarningPortn | read-only | current | Warning On Client SFP DDM :This OID indicates a warning is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Warning has been detecte… |
| 1.3.6.1.4.1.20044.26.2.2.3.8.1.11 | Columnpm1005AlmSfpDdmAlmPortn | read-only | current | Alarm On Client SFP DDM :This OID indicates an alarm is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Alarm has been detected on … |
| 1.3.6.1.4.1.20044.26.2.2.3.8.1.13 | Columnpm1005AlmFailAccPortn | read-only | current | Client Access Fail :This OID indicates a failure on the Client port <Condtype> FAIL_ACC_1 <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12)… |
| 1.3.6.1.4.1.20044.26.2.2.3.8.1.17 | Columnpm1005AlmUpCsfPortn | read-only | current | Client Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu… |
| 1.3.6.1.4.1.20044.26.2.2.3.16 | Tablepm1005AlmaccessioAlmTable | not-accessible | current | List of pm1005AlmaccessioAlm Article |
| 1.3.6.1.4.1.20044.26.2.2.3.16.1 | Rowpm1005AlmaccessioAlmEntry | not-accessible | current | Row definition for the pm1005AlmaccessioAlm table |
| 1.3.6.1.4.1.20044.26.2.2.3.16.1.1 | Columnpm1005AlmaccessioAlmIndex | read-only | current | Index definition for the pm1005AlmaccessioAlm table |
| 1.3.6.1.4.1.20044.26.2.2.3.16.1.2 | Columnpm1005AlmDwLasFailPortn | read-only | current | Client SFP Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the client port (this alarm reports the transmitter failure alarm … |
| 1.3.6.1.4.1.20044.26.2.2.3.16.1.5 | Columnpm1005AlmUpLosPortn | read-only | current | Client Input Loss Of Signal :This OID indicates that no signal is present on the SFP of the client port <Help> This alarm indicates if an optical signal is det… |
| 1.3.6.1.4.1.20044.26.2.2.3.72 | Tablepm1005AlmmapperDeAlmTable | not-accessible | current | List of pm1005AlmmapperDeAlm Article |
| 1.3.6.1.4.1.20044.26.2.2.3.72.1 | Rowpm1005AlmmapperDeAlmEntry | not-accessible | current | Row definition for the pm1005AlmmapperDeAlm table |
| 1.3.6.1.4.1.20044.26.2.2.3.72.1.1 | Columnpm1005AlmmapperDeAlmIndex | read-only | current | Index definition for the pm1005AlmmapperDeAlm table |
| 1.3.6.1.4.1.20044.26.2.2.3.72.1.2 | Columnpm1005AlmUpAccOosPortn | read-only | current | Client Loss Of 10b/8b Synchro :This OID indicates the upstream client input port has lost synchronization on its 10B/8B decoder <Help> This alarms indicates if… |
| 1.3.6.1.4.1.20044.26.2.2.3.72.1.11 | Columnpm1005AlmUpBufferOvlPortn | read-only | current | Client Upstream Buffer Overload :This OID indicates that the rate adaptation buffer for client port is in overload. <Help> This alarm indicates if there is a u… |
| 1.3.6.1.4.1.20044.26.2.2.3.72.1.12 | Columnpm1005AlmDwCsfDetPortn | read-only | current | Client Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client… |
| 1.3.6.1.4.1.20044.26.2.2.3.72.1.15 | Columnpm1005AlmDwBufferOvlPortn | read-only | current | Client Downstream Buffer Overload :This OID indicates that the de-mapper buffer for client port is in overload. <Help> This alarm indicates if there is a downs… |
| 1.3.6.1.4.1.20044.26.2.3 | Nodepm1005AlmLine | |||
| 1.3.6.1.4.1.20044.26.2.3.1 | Nodepm1005AlmLineNurg | |||
| 1.3.6.1.4.1.20044.26.2.3.1.209 | Tablepm1005AlmlineXfp1WarningsTable | not-accessible | current | List of pm1005AlmlineXfp1Warnings Article |
| 1.3.6.1.4.1.20044.26.2.3.1.209.1 | Rowpm1005AlmlineXfp1WarningsEntry | not-accessible | current | Row definition for the pm1005AlmlineXfp1Warnings table |
| 1.3.6.1.4.1.20044.26.2.3.1.209.1.1 | Columnpm1005AlmlineXfp1WarningsIndex | read-only | current | Index definition for the pm1005AlmlineXfp1Warnings table |
| 1.3.6.1.4.1.20044.26.2.3.1.209.1.2 | Columnpm1005AlmTxPowerLowWarningPortn | read-only | current | Line Optical Tx Power Low Warning :Warning indicating that the XFP/OTX transmitter transmitter output power is lower than the threshold value written in the XF… |
| 1.3.6.1.4.1.20044.26.2.3.1.209.1.3 | Columnpm1005AlmTxPowerHighWarningPortn | read-only | current | Line Optical Tx Power High Warning :Warning indicating that the XFP/OTX transmitter transmitter output power is higher than the threshold value written in the … |
| 1.3.6.1.4.1.20044.26.2.3.1.209.1.4 | Columnpm1005AlmTxBiasLowWarningPortn | read-only | current | Line Transceiver Bias Low Warning :Warning indicating that the XFP/OTX transmitter laser bias current is lower than the threshold value written in the XFP/OTX … |
| 1.3.6.1.4.1.20044.26.2.3.1.209.1.5 | Columnpm1005AlmTxBiasHighWarningPortn | read-only | current | Line Transceiver Bias High Warning :Warning indicating that the XFP/OTX transmitter laser bias current is higher than the threshold value written in the XFP EE… |
| 1.3.6.1.4.1.20044.26.2.3.1.209.1.8 | Columnpm1005AlmTempLowWarningPortn | read-only | current | Line Transceiver Temp Low Warning :Warning indicating that the XFP/OTX temperature is lower than the threshold value written in the XFP/OTX EEPROM <Condtype> T… |
| 1.3.6.1.4.1.20044.26.2.3.1.209.1.9 | Columnpm1005AlmTempHighWarningPortn | read-only | current | Line Transceiver Temp High Warning :Warning indicating that the XFP/OTX temperature is higher than the threshold value written in the XFP EEPROM <Condtype> TEM… |
| 1.3.6.1.4.1.20044.26.2.3.1.209.1.16 | Columnpm1005AlmRxPowerLowWarningPortn | read-only | current | Line Optical Rx Power Low Warning :Warning indicating that the XFP received optical power is lower than the threshold value written in the XFP EEPROM <Condtype… |
| 1.3.6.1.4.1.20044.26.2.3.1.209.1.17 | Columnpm1005AlmRxPowerHighWarningPortn | read-only | current | Line Optical Rx Power High Warning :Warning indicating that the XFP received optical power is higher than the threshold value written in the XFP EEPROM <Condty… |
| 1.3.6.1.4.1.20044.26.2.3.1.225 | Tablepm1005AlmlineOtx1TlhWarningsTable | not-accessible | current | List of pm1005AlmlineOtx1TlhWarnings Article |
| 1.3.6.1.4.1.20044.26.2.3.1.225.1 | Rowpm1005AlmlineOtx1TlhWarningsEntry | not-accessible | current | Row definition for the pm1005AlmlineOtx1TlhWarnings table |
| 1.3.6.1.4.1.20044.26.2.3.1.225.1.1 | Columnpm1005AlmlineOtx1TlhWarningsIndex | read-only | current | Index definition for the pm1005AlmlineOtx1TlhWarnings table |
| 1.3.6.1.4.1.20044.26.2.3.1.225.1.6 | Columnpm1005AlmLineModulatorAgingHighWarningPortn | read-only | current | Line Modulator Aging High Warning :Warning indicating the Line OTX TLH modulator aging is higher than the threshold written in the EEPROM <Condtype> LINE_MODUL… |
| 1.3.6.1.4.1.20044.26.2.3.1.225.1.7 | Columnpm1005AlmLineAgingHighWarningPortn | read-only | current | Line OTX TLH Aging High Warning :Warning indicating the Line OTX TLH aging is higher than the threshold written in the EEPROM <Condtype> LINE_AGING_HIGH_WARNIN… |
| 1.3.6.1.4.1.20044.26.2.3.1.225.1.13 | Columnpm1005AlmLineFreqDevHighWarningPortn | read-only | current | Line Freq. Deviation High Warning :Warning indicating the Line OTX TLH frequency deviation is higher than the threshold written in the EEPROM <Condtype> LINE_F… |
| 1.3.6.1.4.1.20044.26.2.3.1.225.1.15 | Columnpm1005AlmLineLaserTempHighWarningPortn | read-only | current | Line Laser Temp. High Warning :Warning indicating the Line OTX TLH laser temperature is higher than the threshold written in the EEPROM <Condtype> LINE_LASER_T… |
| 1.3.6.1.4.1.20044.26.2.3.2 | Nodepm1005AlmLineUrg | |||
| 1.3.6.1.4.1.20044.26.2.3.2.129 | Tablepm1005AlmdfrmBerTable | not-accessible | current | List of pm1005AlmdfrmBer Article |
| 1.3.6.1.4.1.20044.26.2.3.2.129.1 | Rowpm1005AlmdfrmBerEntry | not-accessible | current | Row definition for the pm1005AlmdfrmBer table |
| 1.3.6.1.4.1.20044.26.2.3.2.129.1.1 | Columnpm1005AlmdfrmBerIndex | read-only | current | Index definition for the pm1005AlmdfrmBer table |
| 1.3.6.1.4.1.20044.26.2.3.2.129.1.2 | Columnpm1005AlmLineSignalDegradePortn | read-only | current | Custom Line Signal Degrade :This OID indicates that the line input signal is DEGRADE. The assertion hysteresis can customized by the host <Condtype> LINE_SIGNA… |
| 1.3.6.1.4.1.20044.26.2.3.2.129.1.3 | Columnpm1005AlmLineSignalFailPortn | read-only | current | Custom Line Signal Fail :This OID indicates that the line input signal is FAIL. The assertion hysteresis can be customized by the host <Condtype> LINE_SIGNAL_F… |
| 1.3.6.1.4.1.20044.26.2.3.2.129.1.6 | Columnpm1005AlmLineDegradePortn | read-only | current | Fixed Line Signal Degrade :This OID indicates that the line input signal is DEGRADE. The assetion hysteresis is fixed to 10-8 (assertion) and 10-9 (de-assertio… |
| 1.3.6.1.4.1.20044.26.2.3.2.208 | Tablepm1005AlmlineXfp1AlarmTable | not-accessible | current | List of pm1005AlmlineXfp1Alarm Article |
| 1.3.6.1.4.1.20044.26.2.3.2.208.1 | Rowpm1005AlmlineXfp1AlarmEntry | not-accessible | current | Row definition for the pm1005AlmlineXfp1Alarm table |
| 1.3.6.1.4.1.20044.26.2.3.2.208.1.1 | Columnpm1005AlmlineXfp1AlarmIndex | read-only | current | Index definition for the pm1005AlmlineXfp1Alarm table |
| 1.3.6.1.4.1.20044.26.2.3.2.208.1.2 | Columnpm1005AlmTxPowerLowAlarmPortn | read-only | current | Line Optical Tx Power Low :Alarm indicating that the XFP/OTX transmitter transmitter output power is lower than the threshold value written in the XFP/OTX EEPR… |
| 1.3.6.1.4.1.20044.26.2.3.2.208.1.3 | Columnpm1005AlmTxPowerHighAlarmPortn | read-only | current | Line Optical Tx Power High :Alarm indicating that the XFP/OTX transmitter transmitter output power is higher than the threshold value written in the XFP EEPROM… |
| 1.3.6.1.4.1.20044.26.2.3.2.208.1.4 | Columnpm1005AlmTxBiasLowAlarmPortn | read-only | current | Line Transceiver Bias Low :Alarm indicating that the XFP/OTX transmitter laser bias current is lower than the threshold value written in the XFP/OTX EEPROM <Co… |
| 1.3.6.1.4.1.20044.26.2.3.2.208.1.5 | Columnpm1005AlmTxBiasHighAlarmPortn | read-only | current | Line Transceiver Bias High :Alarm indicating that the XFP/OTX transmitter laser bias current is higher than the threshold value written in the XFP EEPROM <Cond… |
| 1.3.6.1.4.1.20044.26.2.3.2.208.1.8 | Columnpm1005AlmTempLowAlarmPortn | read-only | current | Line Transceiver Temp Low :Alarm indicating that the XFP/OTX temperature is lower than the threshold value written in the XFP/OTX EEPROM <Condtype> TEMP_LOW_AL… |
| 1.3.6.1.4.1.20044.26.2.3.2.208.1.9 | Columnpm1005AlmTempHighAlarmPortn | read-only | current | Line Transceiver Temp High :Alarm indicating that the XFP/OTX temperature is higher than the threshold value written in the XFP EEPROM <Condtype> TEMP_HIGH_ALA… |
| 1.3.6.1.4.1.20044.26.2.3.2.208.1.16 | Columnpm1005AlmRxPowerLowAlarmPortn | read-only | current | Line Optical Rx Power Low :Alarm indicating that the XFP received optical power is lower than the threshold value written in the XFP EEPROM <Condtype> RX_POWER… |
| 1.3.6.1.4.1.20044.26.2.3.2.208.1.17 | Columnpm1005AlmRxPowerHighAlarmPortn | read-only | current | Line Optical Rx Power High :Alarm indicating that the XFP received optical power is higher than the threshold value written in the XFP EEPROM <Condtype> RX_POW… |
| 1.3.6.1.4.1.20044.26.2.3.2.212 | Tablepm1005AlmlineXfp1SupplyAlarmTable | not-accessible | current | List of pm1005AlmlineXfp1SupplyAlarm Article |
| 1.3.6.1.4.1.20044.26.2.3.2.212.1 | Rowpm1005AlmlineXfp1SupplyAlarmEntry | not-accessible | current | Row definition for the pm1005AlmlineXfp1SupplyAlarm table |
| 1.3.6.1.4.1.20044.26.2.3.2.212.1.1 | Columnpm1005AlmlineXfp1SupplyAlarmIndex | read-only | current | Index definition for the pm1005AlmlineXfp1SupplyAlarm table |
| 1.3.6.1.4.1.20044.26.2.3.2.212.1.2 | Columnpm1005AlmVee5LowAlarmPortn | read-only | current | VEE5 Power Supply Low :Alarm indicating the XFP/OTX VEE5 power supply is lower than the threshold written in the EEPROM <Condtype> VEE5_LOW_ALARM_1 <Probcause>… |
| 1.3.6.1.4.1.20044.26.2.3.2.212.1.3 | Columnpm1005AlmVee5HighAlarmPortn | read-only | current | VEE5 Power Supply High :Alarm indicating the XFP/OTX VEE5 power supply is higher than the threshold written in the EEPROM <Condtype> VEE5_HIGH_ALARM_1 <Probcau… |
| 1.3.6.1.4.1.20044.26.2.3.2.212.1.4 | Columnpm1005AlmVcc2LowAlarmPortn | read-only | current | VCC2 Power Supply Low :Alarm indicating the XFP/OTX VCC2 power supply is lower than the threshold written in the EEPROM <Condtype> VCC2_LOW_ALARM_1 <Probcause>… |
| 1.3.6.1.4.1.20044.26.2.3.2.212.1.5 | Columnpm1005AlmVcc2HighAlarmPortn | read-only | current | VCC2 Power Supply High :Alarm indicating the XFP/OTX VCC2 power supply is higher than the threshold written in the EEPROM <Condtype> VCC2_HIGH_ALARM_1 <Probcau… |
| 1.3.6.1.4.1.20044.26.2.3.2.212.1.6 | Columnpm1005AlmVcc3LowAlarmPortn | read-only | current | VCC3 Power Supply Low :Alarm indicating the XFP/OTX VCC3 power supply is lower than the threshold written in the EEPROM <Condtype> VCC3_LOW_ALARM_1 <Probcause>… |
| 1.3.6.1.4.1.20044.26.2.3.2.212.1.7 | Columnpm1005AlmVcc3HighAlarmPortn | read-only | current | VCC3 Power Supply High :Alarm indicating the XFP/OTX VCC3 power supply is higher than the threshold written in the EEPROM <Condtype> VCC3_HIGH_ALARM_1 <Probcau… |
| 1.3.6.1.4.1.20044.26.2.3.2.212.1.8 | Columnpm1005AlmVcc5LowAlarmPortn | read-only | current | VCC5 Power Supply Low :Alarm indicating the XFP/OTX VCC5 power supply is lower than the threshold written in the EEPROM <Condtype> VCC5_LOW_ALARM_1 <Probcause>… |
| 1.3.6.1.4.1.20044.26.2.3.2.212.1.9 | Columnpm1005AlmVcc5HighAlarmPortn | read-only | current | VCC5 Power Supply High :Alarm indicating the XFP/OTX VCC5 power supply is higher than the threshold written in the EEPROM <Condtype> VCC5_HIGH_ALARM_1 <Probcau… |
| 1.3.6.1.4.1.20044.26.2.3.2.212.1.10 | Columnpm1005AlmVee5LowWarningPortn | read-only | current | VEE5 Power Supply Low Warning :Warning indicating the XFP/OTX VEE5 power supply is lower than the threshold written in the EEPROM <Condtype> VEE5_LOW_WARNING_1… |
| 1.3.6.1.4.1.20044.26.2.3.2.212.1.11 | Columnpm1005AlmVee5HighWarningPortn | read-only | current | VEE5 Power Supply High Warning :Warning indicating the XFP/OTX VEE5 power supply is higher than the threshold written in the EEPROM <Condtype> VEE5_HIGH_WARNIN… |
| 1.3.6.1.4.1.20044.26.2.3.2.212.1.12 | Columnpm1005AlmVcc2LowWarningPortn | read-only | current | VCC2 Power Supply Low Warning :Warning indicating the XFP/OTX VCC2 power supply is lower than the threshold written in the EEPROM <Condtype> VCC2_LOW_WARNING_1… |
| 1.3.6.1.4.1.20044.26.2.3.2.212.1.13 | Columnpm1005AlmVcc2HighWarningPortn | read-only | current | VCC2 Power Supply High Warning :Warning indicating the XFP/OTX VCC2 power supply is higher than the threshold written in the EEPROM <Condtype> VCC2_HIGH_WARNIN… |
| 1.3.6.1.4.1.20044.26.2.3.2.212.1.14 | Columnpm1005AlmVcc3LowWarningPortn | read-only | current | VCC3 Power Supply Low Warning :Warning indicating the XFP/OTX VCC3 power supply is lower than the threshold written in the EEPROM <Condtype> VCC3_LOW_WARNING_1… |
| 1.3.6.1.4.1.20044.26.2.3.2.212.1.15 | Columnpm1005AlmVcc3HighWarningPortn | read-only | current | VCC3 Power Supply High Warning :Warning indicating the XFP/OTX VCC3 power supply is higher than the threshold written in the EEPROM <Condtype> VCC3_HIGH_WARNIN… |
| 1.3.6.1.4.1.20044.26.2.3.2.212.1.16 | Columnpm1005AlmVcc5LowWarningPortn | read-only | current | VCC5 Power Supply Low Warning :Warning indicating the XFP/OTX VCC5 power supply is lower than the threshold written in the EEPROM <Condtype> VCC5_LOW_WARNING_1… |
| 1.3.6.1.4.1.20044.26.2.3.2.212.1.17 | Columnpm1005AlmVcc5HighWarningPortn | read-only | current | VCC5 Power Supply High Warning :Warning indicating the XFP/OTX VCC5 power supply is higher than the threshold written in the EEPROM <Condtype> VCC5_HIGH_WARNIN… |
| 1.3.6.1.4.1.20044.26.2.3.2.224 | Tablepm1005AlmlineOtx1TlhAlarmsTable | not-accessible | current | List of pm1005AlmlineOtx1TlhAlarms Article |
| 1.3.6.1.4.1.20044.26.2.3.2.224.1 | Rowpm1005AlmlineOtx1TlhAlarmsEntry | not-accessible | current | Row definition for the pm1005AlmlineOtx1TlhAlarms table |
| 1.3.6.1.4.1.20044.26.2.3.2.224.1.1 | Columnpm1005AlmlineOtx1TlhAlarmsIndex | read-only | current | Index definition for the pm1005AlmlineOtx1TlhAlarms table |
| 1.3.6.1.4.1.20044.26.2.3.2.224.1.6 | Columnpm1005AlmLineModulatorAgingHighAlaPortn | read-only | current | Line Modulator Aging High Alarm :Alarm indicating the Line OTX TLH modulator aging is higher than the threshold written in the EEPROM <Condtype> LINE_MODULATOR… |
| 1.3.6.1.4.1.20044.26.2.3.2.224.1.7 | Columnpm1005AlmLineAgingHighAlaPortn | read-only | current | Line OTX TLH Aging High Alarm :Alarm indicating the Line OTX TLH aging is higher than the threshold written in the EEPROM <Condtype> LINE_AGING_HIGH_ALA_1 <Pro… |
| 1.3.6.1.4.1.20044.26.2.3.2.224.1.13 | Columnpm1005AlmLineFreqDevHighAlaPortn | read-only | current | Line Freq. Deviation High Alarm :Alarm indicating the Line OTX TLH frequency deviation is higher than the threshold written in the EEPROM <Condtype> LINE_FREQ_… |
| 1.3.6.1.4.1.20044.26.2.3.2.224.1.15 | Columnpm1005AlmLineLaserTempHighAlaPortn | read-only | current | Line Laser Temp. High Alarm :Alarm indicating the Line OTX TLH laser temperature is higher than the threshold written in the EEPROM <Condtype> LINE_LASER_TEMP_… |
| 1.3.6.1.4.1.20044.26.2.3.3 | Nodepm1005AlmLineCrit | |||
| 1.3.6.1.4.1.20044.26.2.3.3.7 | Tablepm1005AlmsynthAlmLineTable | not-accessible | current | List of pm1005AlmsynthAlmLine Article |
| 1.3.6.1.4.1.20044.26.2.3.3.7.1 | Rowpm1005AlmsynthAlmLineEntry | not-accessible | current | Row definition for the pm1005AlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.26.2.3.3.7.1.1 | Columnpm1005AlmsynthAlmLineIndex | read-only | current | Index definition for the pm1005AlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.26.2.3.3.7.1.2 | Columnpm1005AlmXfpAbsentPortn | read-only | current | Line Optical Module Absent :This OID indicates that the line optical interface (XFP or OTX) is not plugged in. <Help> This alarm indicates if the line transcei… |
| 1.3.6.1.4.1.20044.26.2.3.3.7.1.3 | Columnpm1005AlmXfpInitNotComplPortn | read-only | current | Line Optical Module Ready :This OID indicates that the optical interface (XFP or OTX) is not operational. <Help> This status indicates if the line transceiver … |
| 1.3.6.1.4.1.20044.26.2.3.3.7.1.5 | Columnpm1005AlmLineHwFailPortn | read-only | current | Line Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Condtype> LINE_HW_FAIL <Probcause> equipmentMalfunction (1… |
| 1.3.6.1.4.1.20044.26.2.3.3.7.1.6 | Columnpm1005AlmXfpTxOffPortn | read-only | current | Line Optical Module Laser Shutdown :This OID indicates the line optical output power is on <Help> This status indicates if the line transceiver laser is ON or … |
| 1.3.6.1.4.1.20044.26.2.3.3.7.1.7 | Columnpm1005AlmLineLocalOosPortn | read-only | current | Line Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service… |
| 1.3.6.1.4.1.20044.26.2.3.3.7.1.9 | Columnpm1005AlmUpRdiInsPortn | read-only | current | MS-RDI/L-RDI Inserted On Line :This OID indicates an upstream MS-RDI/L-RDI has been inserted in the outgoing 10 Gb/s SDH/SONET signal. <Help> This status indic… |
| 1.3.6.1.4.1.20044.26.2.3.3.7.1.10 | Columnpm1005AlmLineDdmWarningPortn | read-only | current | Warning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Warni… |
| 1.3.6.1.4.1.20044.26.2.3.3.7.1.11 | Columnpm1005AlmLineDdmAlmPortn | read-only | current | Alarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Alarm ha… |
| 1.3.6.1.4.1.20044.26.2.3.3.7.1.13 | Columnpm1005AlmLineFailPortn | read-only | current | Line Port Failure :This OID indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12) <Po… |
| 1.3.6.1.4.1.20044.26.2.3.3.7.1.17 | Columnpm1005AlmLineActivePortn | read-only | current | Line Active :This bit indicates the line #n is active on receive side <Help> This status indicates whether the line is active or standby. <Condtype> LINE_ACTIV… |
| 1.3.6.1.4.1.20044.26.2.3.3.128 | Tablepm1005AlmdfrmAlmTable | not-accessible | current | List of pm1005AlmdfrmAlm Article |
| 1.3.6.1.4.1.20044.26.2.3.3.128.1 | Rowpm1005AlmdfrmAlmEntry | not-accessible | current | Row definition for the pm1005AlmdfrmAlm table |
| 1.3.6.1.4.1.20044.26.2.3.3.128.1.1 | Columnpm1005AlmdfrmAlmIndex | read-only | current | Index definition for the pm1005AlmdfrmAlm table |
| 1.3.6.1.4.1.20044.26.2.3.3.128.1.2 | Columnpm1005AlmDwAisDetPortn | read-only | current | MS-AIS/L-AIS Detected On Line Input :This OID indicates that an MS-AIS has been detected on incoming OC-48c/STM-16c input signal <Help> This alarm indicates if… |
| 1.3.6.1.4.1.20044.26.2.3.3.128.1.3 | Columnpm1005AlmDwRdiDetPortn | read-only | current | MS-RDI/L-RDI Detected On Line Input :This OID indicates that an MS-RDI has been detected on incoming OC-48c/STM-16c input signal <Help> This alarm indicates if… |
| 1.3.6.1.4.1.20044.26.2.3.3.128.1.4 | Columnpm1005AlmDwOofPortn | read-only | current | SONET/SDH Line Out Of Frame :This OID indicates that an Out Of Frame has been detected on incoming OC-48c/STM-16c input signal <Help> This alarm indicates if t… |
| 1.3.6.1.4.1.20044.26.2.3.3.128.1.5 | Columnpm1005AlmDwLofPortn | read-only | current | SONET/SDH Line Loss Of Frame :This OID indicates that a Loss Of Frame has been detected on incoming OC-48c/STM-16c input signal <Help> This alarm indicates if … |
| 1.3.6.1.4.1.20044.26.2.3.3.133 | Tablepm1005AlmlineSyncAlarmsTable | not-accessible | current | List of pm1005AlmlineSyncAlarms Article |
| 1.3.6.1.4.1.20044.26.2.3.3.133.1 | Rowpm1005AlmlineSyncAlarmsEntry | not-accessible | current | Row definition for the pm1005AlmlineSyncAlarms table |
| 1.3.6.1.4.1.20044.26.2.3.3.133.1.1 | Columnpm1005AlmlineSyncAlarmsIndex | read-only | current | Index definition for the pm1005AlmlineSyncAlarms table |
| 1.3.6.1.4.1.20044.26.2.3.3.133.1.13 | Columnpm1005AlmDwLockerrPortn | read-only | current | Downstream Clock Lock Error :This OID indicates that the deserializer input 10 Gb/s clock recovery is not locked. <Condtype> DW_LOCKERR <Probcause> receiveFail… |
| 1.3.6.1.4.1.20044.26.2.3.3.133.1.14 | Columnpm1005AlmUpLockerrPortn | read-only | current | Upstream Clock Lock Error :This OID indicates that the serializer output 10 Gb/s clock multiplier unit is not locked. <Condtype> UP_LOCKERR <Probcause> receive… |
| 1.3.6.1.4.1.20044.26.2.3.3.133.1.17 | Columnpm1005AlmDwLosPortn | read-only | current | Line Input Loss Of Signal :This OID indicates a loss of signal on the 10 Gb/s input. <Help> This alarm indicates if an optical signal is detected on the line t… |
| 1.3.6.1.4.1.20044.26.2.3.3.211 | Tablepm1005AlmlineXfp1AlarmsTable | not-accessible | current | List of pm1005AlmlineXfp1Alarms Article |
| 1.3.6.1.4.1.20044.26.2.3.3.211.1 | Rowpm1005AlmlineXfp1AlarmsEntry | not-accessible | current | Row definition for the pm1005AlmlineXfp1Alarms table |
| 1.3.6.1.4.1.20044.26.2.3.3.211.1.1 | Columnpm1005AlmlineXfp1AlarmsIndex | read-only | current | Index definition for the pm1005AlmlineXfp1Alarms table |
| 1.3.6.1.4.1.20044.26.2.3.3.211.1.3 | Columnpm1005AlmModNrPortn | read-only | current | Line Optical Module Not Ready :This OID indicates that the module is unable to determine correct data. <Help> This alarm indicates if the line transceiver is r… |
| 1.3.6.1.4.1.20044.26.2.3.3.211.1.4 | Columnpm1005AlmRxCdrNotLockedPortn | read-only | current | Line Optical Rx CDR Unlocked :This OID indicates that a loss of lock on the receiving side CDR has been detected <Help> This alarm indicates if the Rx CDR is l… |
| 1.3.6.1.4.1.20044.26.2.3.3.211.1.6 | Columnpm1005AlmRxNrPortn | read-only | current | Line Optical Rx Not Ready :This OID indicates that a condition has arisen leading to invalid data on the receiving side. <Help> This alarm indicates if the Rx … |
| 1.3.6.1.4.1.20044.26.2.3.3.211.1.7 | Columnpm1005AlmTxCdrNotLockedPortn | read-only | current | Line Optical Tx CDR Unlocked :This OID indicates a loss of lock on the transmitting side CDR has been detected. <Help> This alarm indicates if the Tx CDR is lo… |
| 1.3.6.1.4.1.20044.26.2.3.3.211.1.8 | Columnpm1005AlmTxFaultPortn | read-only | current | Line Optical Tx Failure :This OID indicates a fault condition on the laser detected by the safety syste <Help> This alarm indicates if the laser of the line tr… |
| 1.3.6.1.4.1.20044.26.2.3.3.211.1.9 | Columnpm1005AlmTxNrPortn | read-only | current | Line Optical Tx Not Ready :This OID indicates a condition has arisen leading to invalid data on the transmitting side <Help> This alarm indicates if the Tx par… |
| 1.3.6.1.4.1.20044.26.2.3.3.211.1.15 | Columnpm1005AlmWavelengthUnlockedPortn | read-only | current | Line Optical Tx Wavelength Unlocked :This OID indicates that the wavelength error is exceeding the manufacturer tolerance <Help> This alarm indicates if the wa… |
| 1.3.6.1.4.1.20044.26.2.3.3.211.1.16 | Columnpm1005AlmTecFaultPortn | read-only | current | Line Optical Tx Temp Regul Failed :This OID indicates a failure on the TEC module <Help> This alarm indicates if the TEC of the line transceiver is in fail con… |
| 1.3.6.1.4.1.20044.26.2.3.3.211.1.17 | Columnpm1005AlmApdSupplyFaultPortn | read-only | current | Line Rx Photodiode Power Failed :This OID indicates a failure on the APD power supply <Help> This alarm indicates if the APD power supply is in fail condition … |
| 1.3.6.1.4.1.20044.26.3 | Nodepm1005measures | |||
| 1.3.6.1.4.1.20044.26.3.1 | Nodepm1005MesrOther | |||
| 1.3.6.1.4.1.20044.26.3.1.0 | Scalarpm1005Mesrsynth0 | read-only | deprecated | Not Used :This OID gives the unit used on AUX1 measurement of XFP#1 (Unit = ) |
| 1.3.6.1.4.1.20044.26.3.1.1 | Scalarpm1005Mesrsynth1 | read-only | deprecated | Not Used :This OID gives the unit used on AUX2 measurement of XFP#1 (Unit = ) |
| 1.3.6.1.4.1.20044.26.3.2 | Nodepm1005MesrClient | |||
| 1.3.6.1.4.1.20044.26.3.2.16 | Tablepm1005MesrtempMeasTable | not-accessible | current | List of pm1005MesrtempMeas Article |
| 1.3.6.1.4.1.20044.26.3.2.16.1 | Rowpm1005MesrtempMeasEntry | not-accessible | current | Row definition for the pm1005MesrtempMeas table |
| 1.3.6.1.4.1.20044.26.3.2.16.1.1 | Columnpm1005MesrtempMeasIndex | read-only | current | Index definition for the pm1005MesrtempMeas table |
| 1.3.6.1.4.1.20044.26.3.2.16.1.2 | Columnpm1005MesrtempMeasPortn | read-only | current | Client SFP Temperature :This OID gives the temperature value of the SFP plugged in port, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/25… |
| 1.3.6.1.4.1.20044.26.3.2.24 | Tablepm1005MesrvoltMeasTable | not-accessible | current | List of pm1005MesrvoltMeas Article |
| 1.3.6.1.4.1.20044.26.3.2.24.1 | Rowpm1005MesrvoltMeasEntry | not-accessible | current | Row definition for the pm1005MesrvoltMeas table |
| 1.3.6.1.4.1.20044.26.3.2.24.1.1 | Columnpm1005MesrvoltMeasIndex | read-only | current | Index definition for the pm1005MesrvoltMeas table |
| 1.3.6.1.4.1.20044.26.3.2.24.1.2 | Columnpm1005MesrvoltMeasPortn | read-only | current | Client SFP Power Supply :This OID gives the 3V3 voltage value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/100… |
| 1.3.6.1.4.1.20044.26.3.2.32 | Tablepm1005MesrbiasMeasTable | not-accessible | current | List of pm1005MesrbiasMeas Article |
| 1.3.6.1.4.1.20044.26.3.2.32.1 | Rowpm1005MesrbiasMeasEntry | not-accessible | current | Row definition for the pm1005MesrbiasMeas table |
| 1.3.6.1.4.1.20044.26.3.2.32.1.1 | Columnpm1005MesrbiasMeasIndex | read-only | current | Index definition for the pm1005MesrbiasMeas table |
| 1.3.6.1.4.1.20044.26.3.2.32.1.2 | Columnpm1005MesrbiasMeasPortn | read-only | current | Client SFP Laser Bias :This OID gives the bias value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA… |
| 1.3.6.1.4.1.20044.26.3.2.40 | Tablepm1005MesrtxpwrMeasTable | not-accessible | current | List of pm1005MesrtxpwrMeas Article |
| 1.3.6.1.4.1.20044.26.3.2.40.1 | Rowpm1005MesrtxpwrMeasEntry | not-accessible | current | Row definition for the pm1005MesrtxpwrMeas table |
| 1.3.6.1.4.1.20044.26.3.2.40.1.1 | Columnpm1005MesrtxpwrMeasIndex | read-only | current | Index definition for the pm1005MesrtxpwrMeas table |
| 1.3.6.1.4.1.20044.26.3.2.40.1.2 | Columnpm1005MesrtxpwrMeasPortn | read-only | current | Client SFP Tx Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV… |
| 1.3.6.1.4.1.20044.26.3.2.48 | Tablepm1005MesrrxpwrMeasTable | not-accessible | current | List of pm1005MesrrxpwrMeas Article |
| 1.3.6.1.4.1.20044.26.3.2.48.1 | Rowpm1005MesrrxpwrMeasEntry | not-accessible | current | Row definition for the pm1005MesrrxpwrMeas table |
| 1.3.6.1.4.1.20044.26.3.2.48.1.1 | Columnpm1005MesrrxpwrMeasIndex | read-only | current | Index definition for the pm1005MesrrxpwrMeas table |
| 1.3.6.1.4.1.20044.26.3.2.48.1.2 | Columnpm1005MesrrxpwrMeasPortn | read-only | current | Client SFP Rx Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-4… |
| 1.3.6.1.4.1.20044.26.3.3 | Nodepm1005MesrLine | |||
| 1.3.6.1.4.1.20044.26.3.3.208 | Tablepm1005Mesrxfp1LxModTempMeasTable | not-accessible | current | List of pm1005Mesrxfp1LxModTempMeas Article |
| 1.3.6.1.4.1.20044.26.3.3.208.1 | Rowpm1005Mesrxfp1LxModTempMeasEntry | not-accessible | current | Row definition for the pm1005Mesrxfp1LxModTempMeas table |
| 1.3.6.1.4.1.20044.26.3.3.208.1.1 | Columnpm1005Mesrxfp1LxModTempMeasIndex | read-only | current | Index definition for the pm1005Mesrxfp1LxModTempMeas table |
| 1.3.6.1.4.1.20044.26.3.3.208.1.2 | Columnpm1005Mesrxfp1LxModTempMeasPortn | read-only | current | Line Optical Module Temperature :This OID gives the temperature of the XFP or OTX plugged in line#n, read from the DDM (Digital Diagnostic Monitoring) (Tempera… |
| 1.3.6.1.4.1.20044.26.3.3.209 | Tablepm1005Mesrxfp1ReservedTable | not-accessible | deprecated | List of pm1005Mesrxfp1Reserved Article |
| 1.3.6.1.4.1.20044.26.3.3.209.1 | Rowpm1005Mesrxfp1ReservedEntry | not-accessible | deprecated | Row definition for the pm1005Mesrxfp1Reserved table |
| 1.3.6.1.4.1.20044.26.3.3.209.1.1 | Columnpm1005Mesrxfp1ReservedIndex | read-only | deprecated | Index definition for the pm1005Mesrxfp1Reserved table |
| 1.3.6.1.4.1.20044.26.3.3.209.1.2 | Columnpm1005Mesrxfp1ReservedPortn | read-only | deprecated | Not Used :Reserved |
| 1.3.6.1.4.1.20044.26.3.3.210 | Tablepm1005Mesrxfp1LoBiasCurrentMeasTable | not-accessible | current | List of pm1005Mesrxfp1LoBiasCurrentMeas Article |
| 1.3.6.1.4.1.20044.26.3.3.210.1 | Rowpm1005Mesrxfp1LoBiasCurrentMeasEntry | not-accessible | current | Row definition for the pm1005Mesrxfp1LoBiasCurrentMeas table |
| 1.3.6.1.4.1.20044.26.3.3.210.1.1 | Columnpm1005Mesrxfp1LoBiasCurrentMeasIndex | read-only | current | Index definition for the pm1005Mesrxfp1LoBiasCurrentMeas table |
| 1.3.6.1.4.1.20044.26.3.3.210.1.2 | Columnpm1005Mesrxfp1LoBiasCurrentMeasPortn | read-only | current | Line Optical Module Laser Bias :This OID gives the bias value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Bias = A… |
| 1.3.6.1.4.1.20044.26.3.3.211 | Tablepm1005Mesrxfp1LoTxPowerMeasTable | not-accessible | current | List of pm1005Mesrxfp1LoTxPowerMeas Article |
| 1.3.6.1.4.1.20044.26.3.3.211.1 | Rowpm1005Mesrxfp1LoTxPowerMeasEntry | not-accessible | current | Row definition for the pm1005Mesrxfp1LoTxPowerMeas table |
| 1.3.6.1.4.1.20044.26.3.3.211.1.1 | Columnpm1005Mesrxfp1LoTxPowerMeasIndex | read-only | current | Index definition for the pm1005Mesrxfp1LoTxPowerMeas table |
| 1.3.6.1.4.1.20044.26.3.3.211.1.2 | Columnpm1005Mesrxfp1LoTxPowerMeasPortn | read-only | current | Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (… |
| 1.3.6.1.4.1.20044.26.3.3.212 | Tablepm1005Mesrxfp1LiRxPowerMeasTable | not-accessible | current | List of pm1005Mesrxfp1LiRxPowerMeas Article |
| 1.3.6.1.4.1.20044.26.3.3.212.1 | Rowpm1005Mesrxfp1LiRxPowerMeasEntry | not-accessible | current | Row definition for the pm1005Mesrxfp1LiRxPowerMeas table |
| 1.3.6.1.4.1.20044.26.3.3.212.1.1 | Columnpm1005Mesrxfp1LiRxPowerMeasIndex | read-only | current | Index definition for the pm1005Mesrxfp1LiRxPowerMeas table |
| 1.3.6.1.4.1.20044.26.3.3.212.1.2 | Columnpm1005Mesrxfp1LiRxPowerMeasPortn | read-only | current | Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (P… |
| 1.3.6.1.4.1.20044.26.3.3.213 | Tablepm1005Mesrxfp1LxAux1MeasTable | not-accessible | deprecated | List of pm1005Mesrxfp1LxAux1Meas Article |
| 1.3.6.1.4.1.20044.26.3.3.213.1 | Rowpm1005Mesrxfp1LxAux1MeasEntry | not-accessible | deprecated | Row definition for the pm1005Mesrxfp1LxAux1Meas table |
| 1.3.6.1.4.1.20044.26.3.3.213.1.1 | Columnpm1005Mesrxfp1LxAux1MeasIndex | read-only | deprecated | Index definition for the pm1005Mesrxfp1LxAux1Meas table |
| 1.3.6.1.4.1.20044.26.3.3.213.1.2 | Columnpm1005Mesrxfp1LxAux1MeasPortn | read-only | deprecated | Not Used :This OID gives the receive power value read in the DDM (Digital Diagnostic Monitoring) of the XFP or OTX plugged in line #n (Unit = ?) |
| 1.3.6.1.4.1.20044.26.3.3.214 | Tablepm1005Mesrxfp1LxAux2MeasTable | not-accessible | deprecated | List of pm1005Mesrxfp1LxAux2Meas Article |
| 1.3.6.1.4.1.20044.26.3.3.214.1 | Rowpm1005Mesrxfp1LxAux2MeasEntry | not-accessible | deprecated | Row definition for the pm1005Mesrxfp1LxAux2Meas table |
| 1.3.6.1.4.1.20044.26.3.3.214.1.1 | Columnpm1005Mesrxfp1LxAux2MeasIndex | read-only | deprecated | Index definition for the pm1005Mesrxfp1LxAux2Meas table |
| 1.3.6.1.4.1.20044.26.3.3.214.1.2 | Columnpm1005Mesrxfp1LxAux2MeasPortn | read-only | deprecated | Not Used :This OID gives the receive power value read in the DDM (Digital Diagnostic Monitoring) of the XFP or OTX plugged in line #n (Unit = ?) |
| 1.3.6.1.4.1.20044.26.3.3.224 | Tablepm1005Mesrotx1AgingTable | not-accessible | current | List of pm1005Mesrotx1Aging Article |
| 1.3.6.1.4.1.20044.26.3.3.224.1 | Rowpm1005Mesrotx1AgingEntry | not-accessible | current | Row definition for the pm1005Mesrotx1Aging table |
| 1.3.6.1.4.1.20044.26.3.3.224.1.1 | Columnpm1005Mesrotx1AgingIndex | read-only | current | Index definition for the pm1005Mesrotx1Aging table |
| 1.3.6.1.4.1.20044.26.3.3.224.1.2 | Columnpm1005Mesrotx1AgingPortn | read-only | current | Line OTX TLH Aging :This OID gives the aging of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Unit = %) <Help> This measure gives the ag… |
| 1.3.6.1.4.1.20044.26.3.3.225 | Tablepm1005Mesrotx1LaserTemperatureTable | not-accessible | deprecated | List of pm1005Mesrotx1LaserTemperature Article |
| 1.3.6.1.4.1.20044.26.3.3.225.1 | Rowpm1005Mesrotx1LaserTemperatureEntry | not-accessible | deprecated | Row definition for the pm1005Mesrotx1LaserTemperature table |
| 1.3.6.1.4.1.20044.26.3.3.225.1.1 | Columnpm1005Mesrotx1LaserTemperatureIndex | read-only | deprecated | Index definition for the pm1005Mesrotx1LaserTemperature table |
| 1.3.6.1.4.1.20044.26.3.3.225.1.2 | Columnpm1005Mesrotx1LaserTemperaturePortn | read-only | deprecated | Line OTX TLH Laser Temperature :This OID gives the laser temperature of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Unit = C) <Help> T… |
| 1.3.6.1.4.1.20044.26.3.3.226 | Tablepm1005Mesrotx1FreqDeviationTable | not-accessible | current | List of pm1005Mesrotx1FreqDeviation Article |
| 1.3.6.1.4.1.20044.26.3.3.226.1 | Rowpm1005Mesrotx1FreqDeviationEntry | not-accessible | current | Row definition for the pm1005Mesrotx1FreqDeviation table |
| 1.3.6.1.4.1.20044.26.3.3.226.1.1 | Columnpm1005Mesrotx1FreqDeviationIndex | read-only | current | Index definition for the pm1005Mesrotx1FreqDeviation table |
| 1.3.6.1.4.1.20044.26.3.3.226.1.2 | Columnpm1005Mesrotx1FreqDeviationPortn | read-only | current | Line OTX TLH Frequency Deviation :This OID gives the frequency deviation of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Unit = MHz) <H… |
| 1.3.6.1.4.1.20044.26.3.3.227 | Tablepm1005Mesrotx1LaserWvlengthTable | not-accessible | current | List of pm1005Mesrotx1LaserWvlength Article |
| 1.3.6.1.4.1.20044.26.3.3.227.1 | Rowpm1005Mesrotx1LaserWvlengthEntry | not-accessible | current | Row definition for the pm1005Mesrotx1LaserWvlength table |
| 1.3.6.1.4.1.20044.26.3.3.227.1.1 | Columnpm1005Mesrotx1LaserWvlengthIndex | read-only | current | Index definition for the pm1005Mesrotx1LaserWvlength table |
| 1.3.6.1.4.1.20044.26.3.3.227.1.2 | Columnpm1005Mesrotx1LaserWvlengthPortn | read-only | current | Line Optical Module Wavelength :This OID gives the laser wavelength of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Unit = nm) <Help> T… |
| 1.3.6.1.4.1.20044.26.4 | Nodepm1005counters | |||
| 1.3.6.1.4.1.20044.26.4.1 | Nodepm1005CntOther | |||
| 1.3.6.1.4.1.20044.26.4.2 | Nodepm1005CntClient | |||
| 1.3.6.1.4.1.20044.26.4.2.16 | Tablepm1005CntupRaRemCntTable | not-accessible | current | List of pm1005CntupRaRemCnt Article |
| 1.3.6.1.4.1.20044.26.4.2.16.1 | Rowpm1005CntupRaRemCntEntry | not-accessible | current | Row definition for the pm1005CntupRaRemCnt table |
| 1.3.6.1.4.1.20044.26.4.2.16.1.1 | Columnpm1005CntupRaRemCntIndex | read-only | current | Index definition for the pm1005CntupRaRemCnt table |
| 1.3.6.1.4.1.20044.26.4.2.16.1.2 | Columnpm1005CntupRaRemCntValuePortn | read-only | current | Client Rate Adapt. Words Removal :This counter is incremented each time a rate adaptation 10B word is removed from the Client input stream |
| 1.3.6.1.4.1.20044.26.4.2.16.1.3 | Columnpm1005CntupRaRemCntErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the rate adaptation removal counter value is invalid on Port |
| 1.3.6.1.4.1.20044.26.4.2.16.1.4 | Columnpm1005CntupRaRemCntOverloadPortn | read-only | current | Client Counter Overload :This OID when set indicates a rate adaptation removal counter overload on Port |
| 1.3.6.1.4.1.20044.26.4.2.24 | Tablepm1005CntupRaInsCntTable | not-accessible | current | List of pm1005CntupRaInsCnt Article |
| 1.3.6.1.4.1.20044.26.4.2.24.1 | Rowpm1005CntupRaInsCntEntry | not-accessible | current | Row definition for the pm1005CntupRaInsCnt table |
| 1.3.6.1.4.1.20044.26.4.2.24.1.1 | Columnpm1005CntupRaInsCntIndex | read-only | current | Index definition for the pm1005CntupRaInsCnt table |
| 1.3.6.1.4.1.20044.26.4.2.24.1.2 | Columnpm1005CntupRaInsCntValuePortn | read-only | current | Client Rate Adapt. Words Insertion :This counter is incremented each time a rate adaptation 10B word is inserted in the Client input stream |
| 1.3.6.1.4.1.20044.26.4.2.24.1.3 | Columnpm1005CntupRaInsCntErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the rate adaptation insertion counter value is invalid on Port |
| 1.3.6.1.4.1.20044.26.4.2.24.1.4 | Columnpm1005CntupRaInsCntOverloadPortn | read-only | current | Client Counter Overload :This OID when set indicates a rate adaptation insertion counter overload on Port |
| 1.3.6.1.4.1.20044.26.4.2.32 | Tablepm1005CntupRdErrCntTable | not-accessible | current | List of pm1005CntupRdErrCnt Article |
| 1.3.6.1.4.1.20044.26.4.2.32.1 | Rowpm1005CntupRdErrCntEntry | not-accessible | current | Row definition for the pm1005CntupRdErrCnt table |
| 1.3.6.1.4.1.20044.26.4.2.32.1.1 | Columnpm1005CntupRdErrCntIndex | read-only | current | Index definition for the pm1005CntupRdErrCnt table |
| 1.3.6.1.4.1.20044.26.4.2.32.1.2 | Columnpm1005CntupRdErrCntValuePortn | read-only | current | Client Input Errors :This counter is increased each time a 10b/8b running disparity error is detected on the Client input stream <Help> This counter gives the … |
| 1.3.6.1.4.1.20044.26.4.2.32.1.3 | Columnpm1005CntupRdErrCntErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the client error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.26.4.2.32.1.4 | Columnpm1005CntupRdErrCntOverloadPortn | read-only | current | Client Counter Overload :This OID when set indicates a client input error counter overload on Port |
| 1.3.6.1.4.1.20044.26.4.2.40 | Tablepm1005CntupTimCntTable | not-accessible | current | List of pm1005CntupTimCnt Article |
| 1.3.6.1.4.1.20044.26.4.2.40.1 | Rowpm1005CntupTimCntEntry | not-accessible | current | Row definition for the pm1005CntupTimCnt table |
| 1.3.6.1.4.1.20044.26.4.2.40.1.1 | Columnpm1005CntupTimCntIndex | read-only | current | Index definition for the pm1005CntupTimCnt table |
| 1.3.6.1.4.1.20044.26.4.2.40.1.2 | Columnpm1005CntupTimCntValuePortn | read-only | current | Client Upstream Timer Counter :This is the timing counter dedicated to the upstream access counters. It is incremented every 125 us. |
| 1.3.6.1.4.1.20044.26.4.2.40.1.3 | Columnpm1005CntupTimCntErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the upstream timing counter value is invalid on Port |
| 1.3.6.1.4.1.20044.26.4.2.40.1.4 | Columnpm1005CntupTimCntOverloadPortn | read-only | current | Client Counter Overload :This OID when set indicates a upstream timing counter overload on Port |
| 1.3.6.1.4.1.20044.26.4.2.48 | Tablepm1005CntupCvErrCntTable | not-accessible | current | List of pm1005CntupCvErrCnt Article |
| 1.3.6.1.4.1.20044.26.4.2.48.1 | Rowpm1005CntupCvErrCntEntry | not-accessible | current | Row definition for the pm1005CntupCvErrCnt table |
| 1.3.6.1.4.1.20044.26.4.2.48.1.1 | Columnpm1005CntupCvErrCntIndex | read-only | current | Index definition for the pm1005CntupCvErrCnt table |
| 1.3.6.1.4.1.20044.26.4.2.48.1.2 | Columnpm1005CntupCvErrCntValuePortn | read-only | current | Client Coding Violation Counter :This counter is increased each time a 10b/8b coding violation is detected on the Client input stream |
| 1.3.6.1.4.1.20044.26.4.2.48.1.3 | Columnpm1005CntupCvErrCntErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the coding violation counter value is invalid on Port |
| 1.3.6.1.4.1.20044.26.4.2.48.1.4 | Columnpm1005CntupCvErrCntOverloadPortn | read-only | current | Client Counter Overload :This OID when set indicates a coding violation counter overload on Port |
| 1.3.6.1.4.1.20044.26.4.2.64 | Tablepm1005CntdwCbipCntTable | not-accessible | current | List of pm1005CntdwCbipCnt Article |
| 1.3.6.1.4.1.20044.26.4.2.64.1 | Rowpm1005CntdwCbipCntEntry | not-accessible | current | Row definition for the pm1005CntdwCbipCnt table |
| 1.3.6.1.4.1.20044.26.4.2.64.1.1 | Columnpm1005CntdwCbipCntIndex | read-only | current | Index definition for the pm1005CntdwCbipCnt table |
| 1.3.6.1.4.1.20044.26.4.2.64.1.2 | Columnpm1005CntdwCbipCntValuePortn | read-only | current | Client Output Errors :This counter is incremented each time a CBIP parity error is detected on the Client output stream <Help> This counter gives the number of… |
| 1.3.6.1.4.1.20044.26.4.2.64.1.3 | Columnpm1005CntdwCbipCntErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the CBIP error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.26.4.2.64.1.4 | Columnpm1005CntdwCbipCntOverloadPortn | read-only | current | Client CBIP Counter Overload :This OID when set indicates a CBIP error counter overload on Port |
| 1.3.6.1.4.1.20044.26.4.2.72 | Tablepm1005CntdwTimCntTable | not-accessible | current | List of pm1005CntdwTimCnt Article |
| 1.3.6.1.4.1.20044.26.4.2.72.1 | Rowpm1005CntdwTimCntEntry | not-accessible | current | Row definition for the pm1005CntdwTimCnt table |
| 1.3.6.1.4.1.20044.26.4.2.72.1.1 | Columnpm1005CntdwTimCntIndex | read-only | current | Index definition for the pm1005CntdwTimCnt table |
| 1.3.6.1.4.1.20044.26.4.2.72.1.2 | Columnpm1005CntdwTimCntValuePortn | read-only | current | Client Downstream Timer Counter :This is the timing counter dedicated to the downstream access counters. It is incremented every 125 us. |
| 1.3.6.1.4.1.20044.26.4.2.72.1.3 | Columnpm1005CntdwTimCntErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the downstream timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.26.4.2.72.1.4 | Columnpm1005CntdwTimCntOverloadPortn | read-only | current | Client Counter Overload :This OID when set indicates a downstream timer counter overload on Port |
| 1.3.6.1.4.1.20044.26.4.3 | Nodepm1005CntLine | |||
| 1.3.6.1.4.1.20044.26.4.3.152 | Tablepm1005CntdfrmB1ErrCntTable | not-accessible | current | List of pm1005CntdfrmB1ErrCnt Article |
| 1.3.6.1.4.1.20044.26.4.3.152.1 | Rowpm1005CntdfrmB1ErrCntEntry | not-accessible | current | Row definition for the pm1005CntdfrmB1ErrCnt table |
| 1.3.6.1.4.1.20044.26.4.3.152.1.1 | Columnpm1005CntdfrmB1ErrCntIndex | read-only | current | Index definition for the pm1005CntdfrmB1ErrCnt table |
| 1.3.6.1.4.1.20044.26.4.3.152.1.2 | Columnpm1005CntdfrmB1ErrCntValuePortn | read-only | current | Line Input B1 Errors :This counter is incremented each time a B1 error is detected on the Deframer input stream. <Help> This counter gives the number of B1 err… |
| 1.3.6.1.4.1.20044.26.4.3.152.1.3 | Columnpm1005CntdfrmB1ErrCntErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the B1 error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.26.4.3.152.1.4 | Columnpm1005CntdfrmB1ErrCntOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a B1 error counter overload on Port |
| 1.3.6.1.4.1.20044.26.4.3.153 | Tablepm1005CntdfrmTimCntTable | not-accessible | current | List of pm1005CntdfrmTimCnt Article |
| 1.3.6.1.4.1.20044.26.4.3.153.1 | Rowpm1005CntdfrmTimCntEntry | not-accessible | current | Row definition for the pm1005CntdfrmTimCnt table |
| 1.3.6.1.4.1.20044.26.4.3.153.1.1 | Columnpm1005CntdfrmTimCntIndex | read-only | current | Index definition for the pm1005CntdfrmTimCnt table |
| 1.3.6.1.4.1.20044.26.4.3.153.1.2 | Columnpm1005CntdfrmTimCntValuePortn | read-only | current | Line Timer Counter :This is the timing counter dedicated to the downstream deframer counters. It is incremented every 125 us. |
| 1.3.6.1.4.1.20044.26.4.3.153.1.3 | Columnpm1005CntdfrmTimCntErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.26.4.3.153.1.4 | Columnpm1005CntdfrmTimCntOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.26.4.3.154 | Tablepm1005CntdfrmPrimLineErrCntTable | not-accessible | current | List of pm1005CntdfrmPrimLineErrCnt Article |
| 1.3.6.1.4.1.20044.26.4.3.154.1 | Rowpm1005CntdfrmPrimLineErrCntEntry | not-accessible | current | Row definition for the pm1005CntdfrmPrimLineErrCnt table |
| 1.3.6.1.4.1.20044.26.4.3.154.1.1 | Columnpm1005CntdfrmPrimLineErrCntIndex | read-only | current | Index definition for the pm1005CntdfrmPrimLineErrCnt table |
| 1.3.6.1.4.1.20044.26.4.3.154.1.2 | Columnpm1005CntdfrmPrimLineErrCntValuePortn | read-only | current | Line Input FEC Corrected Errors :This counter is incremented each time the FEC is correcting an error on the line input stream. <Help> This counter gives the n… |
| 1.3.6.1.4.1.20044.26.4.3.154.1.3 | Columnpm1005CntdfrmPrimLineErrCntErrorPortn | read-only | current | FEC Counter Error :This bit when set indicates the FEC corrected errors counter value is invalid on Line |
| 1.3.6.1.4.1.20044.26.4.3.154.1.4 | Columnpm1005CntdfrmPrimLineErrCntOverloadPortn | read-only | current | FEC Counter Overload :This bit when set indicates a FEC corrected errors counter overload on Line |
| 1.3.6.1.4.1.20044.26.4.259 | Scalarpm1005CntCountersReset | read-write | current | Counters Reset:This OID resets and restarts all the counters |
| 1.3.6.1.4.1.20044.26.4.260 | Scalarpm1005CntCountersStop | read-write | current | Counters stop:This OID stops all the counters |
| 1.3.6.1.4.1.20044.26.6 | Nodepm1005controlsWrite | |||
| 1.3.6.1.4.1.20044.26.6.1 | Nodepm1005CtrlOther | |||
| 1.3.6.1.4.1.20044.26.6.1.1 | Nodepm1005CtrlconfMgnt1 | |||
| 1.3.6.1.4.1.20044.26.6.1.1.1 | Scalarpm1005CtrlConf1Load1 | read-write | current | Load Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM. |
| 1.3.6.1.4.1.20044.26.6.1.1.2 | Scalarpm1005CtrlConf2Load1 | read-write | current | Load Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM. |
| 1.3.6.1.4.1.20044.26.6.1.1.10 | Scalarpm1005CtrlConf2Flash1 | read-write | current | Write Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura… |
| 1.3.6.1.4.1.20044.26.6.1.1.14 | Scalarpm1005CtrlConf2Clear1 | read-write | current | Clear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o… |
| 1.3.6.1.4.1.20044.26.6.1.4 | Nodepm1005Ctrlsynth4 | |||
| 1.3.6.1.4.1.20044.26.6.1.4.1 | Scalarpm1005CtrlCorrelatOn | read-write | current | Enable Alarm Correlation :This OID enables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.26.6.1.4.2 | Scalarpm1005CtrlCorrelatOff | read-write | current | Disable Alarm Correlation :This OID disables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.26.6.1.5 | Nodepm1005CtrlswMgnt | |||
| 1.3.6.1.4.1.20044.26.6.1.5.2 | Scalarpm1005CtrlColdReset | read-write | current | PM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> … |
| 1.3.6.1.4.1.20044.26.6.1.5.3 | Scalarpm1005CtrlWarmReset | read-write | current | PM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th… |
| 1.3.6.1.4.1.20044.26.6.1.5.5 | Scalarpm1005CtrlLoadSwBank1 | read-write | current | Set Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW… |
| 1.3.6.1.4.1.20044.26.6.1.5.6 | Scalarpm1005CtrlLoadSwBank2 | read-write | current | Set Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S… |
| 1.3.6.1.4.1.20044.26.6.1.6 | Nodepm1005CtrlgwMgnt | |||
| 1.3.6.1.4.1.20044.26.6.1.6.1 | Scalarpm1005CtrlCurrentGwReset | read-write | current | Active Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting. |
| 1.3.6.1.4.1.20044.26.6.1.6.5 | Scalarpm1005CtrlLoadGwBank1 | read-write | current | Set Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.26.6.1.6.6 | Scalarpm1005CtrlLoadGwBank2 | read-write | current | Set Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.26.6.1.6.7 | Scalarpm1005CtrlLoadGwBank3 | read-write | current | Set Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.26.6.1.6.8 | Scalarpm1005CtrlLoadGwBank4 | read-write | current | Set Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.26.6.1.192 | Nodepm1005CtrlledTest | |||
| 1.3.6.1.4.1.20044.26.6.1.192.1 | Scalarpm1005CtrlGreenLed | read-write | current | Green Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green |
| 1.3.6.1.4.1.20044.26.6.1.192.2 | Scalarpm1005CtrlRedLed | read-write | current | Red Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red |
| 1.3.6.1.4.1.20044.26.6.1.192.3 | Scalarpm1005CtrlLedOff | read-write | current | Leds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF |
| 1.3.6.1.4.1.20044.26.6.1.193 | Nodepm1005CtrlmoduleOosMode | |||
| 1.3.6.1.4.1.20044.26.6.1.193.1 | Scalarpm1005CtrlModuleOosMode | read-write | current | PM Out Of Service :This OID sets the PM Out Of Service <Help> This control defines the service state of the complete module |
| 1.3.6.1.4.1.20044.26.6.1.197 | Nodepm1005CtrlmaintenanceMode | |||
| 1.3.6.1.4.1.20044.26.6.1.197.1 | Scalarpm1005CtrlMaintenanceMode | read-write | current | Module Maintenance Mode :This OID enables the maintenance mode on the PM. <Help> This control enables the maintenance mode on the PM. |
| 1.3.6.1.4.1.20044.26.6.1.198 | Nodepm1005CtrldccEnable | |||
| 1.3.6.1.4.1.20044.26.6.1.198.1 | Scalarpm1005CtrlDccEnable | read-write | current | DCC Enable :This OID enables the DCC mode on the PM <Help> This control enables the DCC mode on the PM |
| 1.3.6.1.4.1.20044.26.6.2 | Nodepm1005CtrlClient | |||
| 1.3.6.1.4.1.20044.26.6.2.16 | Tablepm1005CtrlaccessLoopTable | not-accessible | current | List of pm1005CtrlaccessLoop Article |
| 1.3.6.1.4.1.20044.26.6.2.16.1 | Rowpm1005CtrlaccessLoopEntry | not-accessible | current | Row definition for the pm1005CtrlaccessLoop table |
| 1.3.6.1.4.1.20044.26.6.2.16.1.1 | Columnpm1005CtrlaccessLoopIndex | read-only | current | Index definition for the pm1005CtrlaccessLoop table |
| 1.3.6.1.4.1.20044.26.6.2.16.1.2 | Columnpm1005CtrlaccessLoopPortn | read-write | current | Client Facility Loopback :This OID operates a Client Facility Loopback, looping client input signal on the client output port. The loop is located on the clien… |
| 1.3.6.1.4.1.20044.26.6.2.18 | Tablepm1005CtrlportOosModeTable | not-accessible | current | List of pm1005CtrlportOosMode Article |
| 1.3.6.1.4.1.20044.26.6.2.18.1 | Rowpm1005CtrlportOosModeEntry | not-accessible | current | Row definition for the pm1005CtrlportOosMode table |
| 1.3.6.1.4.1.20044.26.6.2.18.1.1 | Columnpm1005CtrlportOosModeIndex | read-only | current | Index definition for the pm1005CtrlportOosMode table |
| 1.3.6.1.4.1.20044.26.6.2.18.1.2 | Columnpm1005CtrlportOosModePortn | read-write | current | Client Port Out Of Service :This OID sets the client port Out Of Service <Help> This controls defines the service state of the client port |
| 1.3.6.1.4.1.20044.26.6.2.19 | Tablepm1005CtrlsfpOnCtrlTable | not-accessible | current | List of pm1005CtrlsfpOnCtrl Article |
| 1.3.6.1.4.1.20044.26.6.2.19.1 | Rowpm1005CtrlsfpOnCtrlEntry | not-accessible | current | Row definition for the pm1005CtrlsfpOnCtrl table |
| 1.3.6.1.4.1.20044.26.6.2.19.1.1 | Columnpm1005CtrlsfpOnCtrlIndex | read-only | current | Index definition for the pm1005CtrlsfpOnCtrl table |
| 1.3.6.1.4.1.20044.26.6.2.19.1.2 | Columnpm1005CtrlsfpOnCtrlPortn | read-write | current | Client SFP Optical Laser ON :This OID switches on the SFP. |
| 1.3.6.1.4.1.20044.26.6.2.20 | Tablepm1005CtrlsfpOffCtrlTable | not-accessible | current | List of pm1005CtrlsfpOffCtrl Article |
| 1.3.6.1.4.1.20044.26.6.2.20.1 | Rowpm1005CtrlsfpOffCtrlEntry | not-accessible | current | Row definition for the pm1005CtrlsfpOffCtrl table |
| 1.3.6.1.4.1.20044.26.6.2.20.1.1 | Columnpm1005CtrlsfpOffCtrlIndex | read-only | current | Index definition for the pm1005CtrlsfpOffCtrl table |
| 1.3.6.1.4.1.20044.26.6.2.20.1.2 | Columnpm1005CtrlsfpOffCtrlPortn | read-write | current | Client SFP Laser Shutdown :This OID switches off the SFP. <Help> This control defines the laser state of the client transceiver |
| 1.3.6.1.4.1.20044.26.6.2.21 | Tablepm1005CtrlcsfUpInsTable | not-accessible | current | List of pm1005CtrlcsfUpIns Article |
| 1.3.6.1.4.1.20044.26.6.2.21.1 | Rowpm1005CtrlcsfUpInsEntry | not-accessible | current | Row definition for the pm1005CtrlcsfUpIns table |
| 1.3.6.1.4.1.20044.26.6.2.21.1.1 | Columnpm1005CtrlcsfUpInsIndex | read-only | current | Index definition for the pm1005CtrlcsfUpIns table |
| 1.3.6.1.4.1.20044.26.6.2.21.1.2 | Columnpm1005CtrlcsfUpInsPortn | read-write | current | Client Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo… |
| 1.3.6.1.4.1.20044.26.6.2.22 | Tablepm1005CtrlcaisDwInsTable | not-accessible | current | List of pm1005CtrlcaisDwIns Article |
| 1.3.6.1.4.1.20044.26.6.2.22.1 | Rowpm1005CtrlcaisDwInsEntry | not-accessible | current | Row definition for the pm1005CtrlcaisDwIns table |
| 1.3.6.1.4.1.20044.26.6.2.22.1.1 | Columnpm1005CtrlcaisDwInsIndex | read-only | current | Index definition for the pm1005CtrlcaisDwIns table |
| 1.3.6.1.4.1.20044.26.6.2.22.1.2 | Columnpm1005CtrlcaisDwInsPortn | read-write | current | Client AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port |
| 1.3.6.1.4.1.20044.26.6.2.26 | Tablepm1005CtrlclientAccessTermLoopTable | not-accessible | current | List of pm1005CtrlclientAccessTermLoop Article |
| 1.3.6.1.4.1.20044.26.6.2.26.1 | Rowpm1005CtrlclientAccessTermLoopEntry | not-accessible | current | Row definition for the pm1005CtrlclientAccessTermLoop table |
| 1.3.6.1.4.1.20044.26.6.2.26.1.1 | Columnpm1005CtrlclientAccessTermLoopIndex | read-only | current | Index definition for the pm1005CtrlclientAccessTermLoop table |
| 1.3.6.1.4.1.20044.26.6.2.26.1.2 | Columnpm1005CtrlclientAccessTermLoopPortn | read-write | current | Client Terminal Loopback :This OID operates a Client Terminal Loopback, looping client input signal on the client output port. The loop is located on the line … |
| 1.3.6.1.4.1.20044.26.6.2.48 | Tablepm1005CtrlprotocolTable | not-accessible | current | List of pm1005Ctrlprotocol Article |
| 1.3.6.1.4.1.20044.26.6.2.48.1 | Rowpm1005CtrlprotocolEntry | not-accessible | current | Row definition for the pm1005Ctrlprotocol table |
| 1.3.6.1.4.1.20044.26.6.2.48.1.1 | Columnpm1005CtrlprotocolIndex | read-only | current | Index definition for the pm1005Ctrlprotocol table |
| 1.3.6.1.4.1.20044.26.6.2.48.1.2 | Columnpm1005CtrlprotocolPortn | read-write | current | Client Protocol: This OID sets the protocol of the Client port. |
| 1.3.6.1.4.1.20044.26.6.3 | Nodepm1005CtrlLine | |||
| 1.3.6.1.4.1.20044.26.6.3.64 | Nodepm1005CtrlcommAccessLoop | |||
| 1.3.6.1.4.1.20044.26.6.3.64.1 | Scalarpm1005CtrlCommAccessloop | read-write | deprecated | PM Full Access Loop Mode :This OID, when set, puts the module in common access loop back, looping the 10 Gb/s output signal on the 10 Gb/s input. |
| 1.3.6.1.4.1.20044.26.6.3.66 | Nodepm1005CtrllineLoop | |||
| 1.3.6.1.4.1.20044.26.6.3.66.1 | Scalarpm1005CtrlLineLoop | read-write | deprecated | PM Line Loop Mode :This OID, when set at '1' puts the module in line loopback mode, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. The Ups… |
| 1.3.6.1.4.1.20044.26.6.3.67 | Nodepm1005CtrlmsAis | |||
| 1.3.6.1.4.1.20044.26.6.3.67.1 | Scalarpm1005CtrlMsAis | read-write | current | Insert MS-AIS/L-AIS On Line Output :This OID, when set, inserts an MS-AIS/L-AIS in the outgoing STM-64/OC-192 signal. |
| 1.3.6.1.4.1.20044.26.6.3.69 | Tablepm1005CtrlfecDisableTable | not-accessible | current | List of pm1005CtrlfecDisable Article |
| 1.3.6.1.4.1.20044.26.6.3.69.1 | Rowpm1005CtrlfecDisableEntry | not-accessible | current | Row definition for the pm1005CtrlfecDisable table |
| 1.3.6.1.4.1.20044.26.6.3.69.1.1 | Columnpm1005CtrlfecDisableIndex | read-only | current | Index definition for the pm1005CtrlfecDisable table |
| 1.3.6.1.4.1.20044.26.6.3.69.1.2 | Columnpm1005CtrlfecDisablePortn | read-write | current | Forward Error Correction Inhibition :This OID, when set, inhibits the Forward Error Correction feature on the line input <Help> This control enables/disables t… |
| 1.3.6.1.4.1.20044.26.6.3.73 | Nodepm1005CtrlProtMgnt | |||
| 1.3.6.1.4.1.20044.26.6.3.73.1 | Scalarpm1005CtrlLineNumber | read-write | current | Active Line Number : This OID sets the active line number |
| 1.3.6.1.4.1.20044.26.6.3.73.2 | Scalarpm1005CtrlProtMode | read-write | current | Line Switch Mode (Auto Or Manual) :This bit selects the manual (1) or automatic (0) switch method <Help> This control defines the protection switch mode on the… |
| 1.3.6.1.4.1.20044.26.6.3.74 | Tablepm1005CtrllineOosModeTable | not-accessible | current | List of pm1005CtrllineOosMode Article |
| 1.3.6.1.4.1.20044.26.6.3.74.1 | Rowpm1005CtrllineOosModeEntry | not-accessible | current | Row definition for the pm1005CtrllineOosMode table |
| 1.3.6.1.4.1.20044.26.6.3.74.1.1 | Columnpm1005CtrllineOosModeIndex | read-only | current | Index definition for the pm1005CtrllineOosMode table |
| 1.3.6.1.4.1.20044.26.6.3.74.1.2 | Columnpm1005CtrllineOosModePortn | read-write | current | Line Port Out Of Service :This OID sets the line port Out Of Service <Help> This control defines the service state of the line port |
| 1.3.6.1.4.1.20044.26.6.3.208 | Tablepm1005CtrlxfpOnoffTable | not-accessible | current | List of pm1005CtrlxfpOnoff Article |
| 1.3.6.1.4.1.20044.26.6.3.208.1 | Rowpm1005CtrlxfpOnoffEntry | not-accessible | current | Row definition for the pm1005CtrlxfpOnoff table |
| 1.3.6.1.4.1.20044.26.6.3.208.1.1 | Columnpm1005CtrlxfpOnoffIndex | read-only | current | Index definition for the pm1005CtrlxfpOnoff table |
| 1.3.6.1.4.1.20044.26.6.3.208.1.2 | Columnpm1005CtrlxfpOnoffPortn | read-write | current | Line Optical Laser Shutdown :This OID switches off the XFP or the OTX <Help> This control defines the laser state of the line transceiver |
| 1.3.6.1.4.1.20044.26.6.3.209 | Tablepm1005CtrlxfpLineLoopTable | not-accessible | current | List of pm1005CtrlxfpLineLoop Article |
| 1.3.6.1.4.1.20044.26.6.3.209.1 | Rowpm1005CtrlxfpLineLoopEntry | not-accessible | current | Row definition for the pm1005CtrlxfpLineLoop table |
| 1.3.6.1.4.1.20044.26.6.3.209.1.1 | Columnpm1005CtrlxfpLineLoopIndex | read-only | current | Index definition for the pm1005CtrlxfpLineLoop table |
| 1.3.6.1.4.1.20044.26.6.3.209.1.2 | Columnpm1005CtrlxfpLineLoopPortn | read-write | current | Line Facility Loopback :This OID operates a Line Facility Loopback, looping line input signal on the line output port. The loop is located on the line transcei… |
| 1.3.6.1.4.1.20044.26.6.3.210 | Tablepm1005CtrlxfpXfiLoopTable | not-accessible | current | List of pm1005CtrlxfpXfiLoop Article |
| 1.3.6.1.4.1.20044.26.6.3.210.1 | Rowpm1005CtrlxfpXfiLoopEntry | not-accessible | current | Row definition for the pm1005CtrlxfpXfiLoop table |
| 1.3.6.1.4.1.20044.26.6.3.210.1.1 | Columnpm1005CtrlxfpXfiLoopIndex | read-only | current | Index definition for the pm1005CtrlxfpXfiLoop table |
| 1.3.6.1.4.1.20044.26.6.3.210.1.2 | Columnpm1005CtrlxfpXfiLoopPortn | read-write | current | Line Terminal Loopback :This OID operates a Line Terminal Loopback, looping line input signal on the line output port. The loop is located on all client transc… |
| 1.3.6.1.4.1.20044.26.6.3.212 | Tablepm1005CtrllineTunableChannelTable | not-accessible | current | List of pm1005CtrllineTunableChannel Article |
| 1.3.6.1.4.1.20044.26.6.3.212.1 | Rowpm1005CtrllineTunableChannelEntry | not-accessible | current | Row definition for the pm1005CtrllineTunableChannel table |
| 1.3.6.1.4.1.20044.26.6.3.212.1.1 | Columnpm1005CtrllineTunableChannelIndex | read-only | current | Index definition for the pm1005CtrllineTunableChannel table |
| 1.3.6.1.4.1.20044.26.6.3.212.1.2 | Columnpm1005CtrllineTunableChannelPortn | read-write | current | ITU Channel :This OID selects the ITU channel of the Line OTX TLH Laser <Help> This control defines the ITU channel of the Line OTX TLH Laser |
| 1.3.6.1.4.1.20044.26.6.3.213 | Tablepm1005CtrllinePhotodiodeModeTable | not-accessible | current | List of pm1005CtrllinePhotodiodeMode Article |
| 1.3.6.1.4.1.20044.26.6.3.213.1 | Rowpm1005CtrllinePhotodiodeModeEntry | not-accessible | current | Row definition for the pm1005CtrllinePhotodiodeMode table |
| 1.3.6.1.4.1.20044.26.6.3.213.1.1 | Columnpm1005CtrllinePhotodiodeModeIndex | read-only | current | Index definition for the pm1005CtrllinePhotodiodeMode table |
| 1.3.6.1.4.1.20044.26.6.3.213.1.2 | Columnpm1005CtrllinePhotodiodeModePortn | read-write | current | OTX TLH Rx Sens. Mode :This OID defines the Rx sensiblity mode of the Line OTX TLH <Help> This control defines the receiver sensibility mode of the Line OTX TL… |
| 1.3.6.1.4.1.20044.26.6.3.214 | Tablepm1005CtrllinePhotodiodeValueTable | not-accessible | current | List of pm1005CtrllinePhotodiodeValue Article |
| 1.3.6.1.4.1.20044.26.6.3.214.1 | Rowpm1005CtrllinePhotodiodeValueEntry | not-accessible | current | Row definition for the pm1005CtrllinePhotodiodeValue table |
| 1.3.6.1.4.1.20044.26.6.3.214.1.1 | Columnpm1005CtrllinePhotodiodeValueIndex | read-only | current | Index definition for the pm1005CtrllinePhotodiodeValue table |
| 1.3.6.1.4.1.20044.26.6.3.214.1.2 | Columnpm1005CtrllinePhotodiodeValuePortn | read-write | current | OTX TLH Rx Sensibility :This OID sets the Rx sensibility of the Line OTX TLH (custom mode only) <Help> This control defines the receiver sensibility value (onl… |
| 1.3.6.1.4.1.20044.26.6.3.215 | Tablepm1005CtrllinePowerLaserTable | not-accessible | current | List of pm1005CtrllinePowerLaser Article |
| 1.3.6.1.4.1.20044.26.6.3.215.1 | Rowpm1005CtrllinePowerLaserEntry | not-accessible | current | Row definition for the pm1005CtrllinePowerLaser table |
| 1.3.6.1.4.1.20044.26.6.3.215.1.1 | Columnpm1005CtrllinePowerLaserIndex | read-only | current | Index definition for the pm1005CtrllinePowerLaser table |
| 1.3.6.1.4.1.20044.26.6.3.215.1.2 | Columnpm1005CtrllinePowerLaserPortn | read-write | current | Line Laser Output Power [3-5] :This OID sets the output power value on the laser of the Line OTX TLH (AV=Power*10+158) (Unit = dBm) <Help> This control defines… |
| 1.3.6.1.4.1.20044.26.7 | Nodepm1005ri | |||
| 1.3.6.1.4.1.20044.26.7.1 | Nodepm1005riTable | |||
| 1.3.6.1.4.1.20044.26.7.1.1 | Tablepm1005RinvSfpTable | not-accessible | current | List of the SFPs on the selected module |
| 1.3.6.1.4.1.20044.26.7.1.1.1 | Rowpm1005RinvSfpEntry | not-accessible | current | Row definition for the SFP table |
| 1.3.6.1.4.1.20044.26.7.1.1.1.1 | Columnpm1005RinvSfpIndex | read-only | current | Index for SFP table |
| 1.3.6.1.4.1.20044.26.7.1.1.1.2 | Columnpm1005Rinvsfp | read-only | current | Inventory for the SFP: This OID contains the inventory for the SFP |
| 1.3.6.1.4.1.20044.26.7.1.2 | Tablepm1005RinvLineTable | not-accessible | current | List of the XFPs on the selected module |
| 1.3.6.1.4.1.20044.26.7.1.2.1 | Rowpm1005RinvLineEntry | not-accessible | current | Row definition for the XFP table |
| 1.3.6.1.4.1.20044.26.7.1.2.1.1 | Columnpm1005RinvLineIndex | read-only | current | Index for XFP table |
| 1.3.6.1.4.1.20044.26.7.1.2.1.2 | Columnpm1005RinvxfpLine | read-only | current | Inventory for the XFP: This OID contains the inventory for the XFP |
| 1.3.6.1.4.1.20044.26.7.2 | Scalarpm1005RinvReloadInventory | read-write | current | Reload the inventory: This OID triggers an inventory reload. |
| 1.3.6.1.4.1.20044.26.7.3 | Scalarpm1005RinvHwPlatform | read-only | current | HW platform description: This OID contains the description of the Hardware platform. |
| 1.3.6.1.4.1.20044.26.7.4 | Scalarpm1005RinvModulePlatform | read-only | current | Module platform description: This OID contains the description of the Module. |
| 1.3.6.1.4.1.20044.26.7.5 | Scalarpm1005RinvSwPlatform | read-only | current | SW platform description: This OID contains the description of the Software platform. |
| 1.3.6.1.4.1.20044.26.7.6 | Scalarpm1005RinvGwPlatform | read-only | current | GW platform desciption: This OID contains the description of the Gateware platform. |
| 1.3.6.1.4.1.20044.26.8 | Nodepm1005download | |||
| 1.3.6.1.4.1.20044.26.8.1 | Nodepm1005DwlOther | |||
| 1.3.6.1.4.1.20044.26.8.1.0 | Nodepm1005DwlrestartProcess | |||
| 1.3.6.1.4.1.20044.26.8.1.0.1 | Scalarpm1005DwlWarmRestartProcessed | read-only | current | Warm Restart :This OID indicates that the module last restart was a Warm RESTART |
| 1.3.6.1.4.1.20044.26.8.1.0.2 | Scalarpm1005DwlColdRestartProcessed | read-only | current | Cold Restart :This OID indicates that the module last restart was a Cold RESTART |
| 1.3.6.1.4.1.20044.26.8.1.1 | Nodepm1005DwlswBanksUsed | |||
| 1.3.6.1.4.1.20044.26.8.1.1.1 | Scalarpm1005DwlSwBank1Used | read-only | current | SW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.26.8.1.1.2 | Scalarpm1005DwlSwBank2Used | read-only | current | SW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby |
| 1.3.6.1.4.1.20044.26.8.1.1.5 | Scalarpm1005DwlSwBank1Notempty | read-only | current | SW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package |
| 1.3.6.1.4.1.20044.26.8.1.1.6 | Scalarpm1005DwlSwBank2Notempty | read-only | current | SW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package |
| 1.3.6.1.4.1.20044.26.8.1.2 | Nodepm1005DwlgwBanksUsed | |||
| 1.3.6.1.4.1.20044.26.8.1.2.1 | Scalarpm1005DwlGwBank1Used | read-only | current | GW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.26.8.1.2.2 | Scalarpm1005DwlGwBank2Used | read-only | current | GW bank 2 active :This OID indicates the module is working on GW bank 2 |
| 1.3.6.1.4.1.20044.26.8.1.2.3 | Scalarpm1005DwlGwBank3Used | read-only | current | GW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby |
| 1.3.6.1.4.1.20044.26.8.1.2.4 | Scalarpm1005DwlGwBank4Used | read-only | current | GW bank 4 active :This OID indicates the module is working on GW bank 4 |
| 1.3.6.1.4.1.20044.26.8.1.2.5 | Scalarpm1005DwlGwBank1Notempty | read-only | current | GW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package |
| 1.3.6.1.4.1.20044.26.8.1.2.6 | Scalarpm1005DwlGwBank2Notempty | read-only | current | GW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2 |
| 1.3.6.1.4.1.20044.26.8.1.2.7 | Scalarpm1005DwlGwBank3Notempty | read-only | current | GW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package |
| 1.3.6.1.4.1.20044.26.8.1.2.8 | Scalarpm1005DwlGwBank4Notempty | read-only | current | GW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4 |
| 1.3.6.1.4.1.20044.26.8.2 | Nodepm1005DwlClient | |||
| 1.3.6.1.4.1.20044.26.8.3 | Nodepm1005DwlLine | |||
| 1.3.6.1.4.1.20044.26.9 | Nodepm1005Config | |||
| 1.3.6.1.4.1.20044.26.9.1 | Nodepm1005CfgAccessCAisCsf | |||
| 1.3.6.1.4.1.20044.26.9.1.1 | Tablepm1005CfgClientcaiscsfTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.26.9.1.1.1 | Rowpm1005CfgClientcaiscsfEntry | not-accessible | current | Row definition for the accessCAisCsf table |
| 1.3.6.1.4.1.20044.26.9.1.1.1.1 | Columnpm1005CfgClientcaiscsfIndex | read-only | current | Index definition for the clientcaiscsf table |
| 1.3.6.1.4.1.20044.26.9.1.1.1.3 | Columnpm1005CfgCAisModePortn | read-write | current | CAIS mode on Client Port :This register enables/disables port laser shutdown on CAIS insertion condition |
| 1.3.6.1.4.1.20044.26.9.1.1.1.9 | Columnpm1005CfgUpAccessioAlmPortn | read-write | current | CSF contributors on Client Port :This register configures the contributors to upstream CSF insertion on the port. |
| 1.3.6.1.4.1.20044.26.9.1.1.1.10 | Columnpm1005CfgUpMapperDeAlmPortn | read-write | current | CSF contributors on Client Port :This register configures the contributors to upstream CSF insertion on the port. |
| 1.3.6.1.4.1.20044.26.9.1.1.1.17 | Columnpm1005CfgDownAccessioAlmPortn | read-write | current | CAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port. |
| 1.3.6.1.4.1.20044.26.9.1.1.1.18 | Columnpm1005CfgDownMapperDeAlmPortn | read-write | current | CAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port. |
| 1.3.6.1.4.1.20044.26.9.1.1.1.19 | Columnpm1005CfgDownDfrmAlmPortn | read-write | current | CAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port. |
| 1.3.6.1.4.1.20044.26.9.1.1.1.20 | Columnpm1005CfgDownLineSyncAlarmsPortn | read-write | deprecated | CAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port. |
| 1.3.6.1.4.1.20044.26.9.2 | Nodepm1005CfgStartup | |||
| 1.3.6.1.4.1.20044.26.9.2.1 | Tablepm1005CfgClientStartupTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.26.9.2.1.1 | Rowpm1005CfgClientStartupEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.26.9.2.1.1.1 | Columnpm1005CfgClientStartupIndex | read-only | current | Index definition for the clientStartup table |
| 1.3.6.1.4.1.20044.26.9.2.1.1.3 | Columnpm1005CfgSystConfPortPortn | read-write | current | Default Settings on Client Port :This register configures the default initialisation settings on the port. |
| 1.3.6.1.4.1.20044.26.9.2.1.1.4 | Columnpm1005CfgNetConfPortPortn | read-write | current | Default Protocol on Client Port :This register configures the default initialisation protocol on the port. |
| 1.3.6.1.4.1.20044.26.9.2.2 | Nodepm1005tablelineStartup | |||
| 1.3.6.1.4.1.20044.26.9.2.2.2 | Scalarpm1005CfgsystConfLine1 | read-write | current | Default Settings on Line 1 :This register configures the default initialisation settings on Line port 1. |
| 1.3.6.1.4.1.20044.26.9.2.2.5 | Scalarpm1005CfglineOptions1 | read-write | current | Default Options on Active Line Port :This register configures the default options on the active line port |
| 1.3.6.1.4.1.20044.26.9.2.2.6 | Scalarpm1005CfgsystConfLine2 | read-write | current | Default Settings on Line 2 :This register configures the default initialisation settings on Line port 2. |
| 1.3.6.1.4.1.20044.26.9.2.2.7 | Scalarpm1005CfglineSelection | read-write | current | Default Settings of active line :This register configures the start up active line. |
| 1.3.6.1.4.1.20044.26.9.2.3 | Tablepm1005CfgXfpTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.26.9.2.3.1 | Rowpm1005CfgXfpEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.26.9.2.3.1.1 | Columnpm1005CfgXfpIndex | read-only | current | Index definition for the xfp table |
| 1.3.6.1.4.1.20044.26.9.2.3.1.3 | Columnpm1005CfgSystConfXfpPortn | read-write | current | Default settings on XFP Port :This register configures the default initialisation settings on XFP port. |
| 1.3.6.1.4.1.20044.26.9.2.3.1.4 | Columnpm1005CfgDataRateConfXfpPortn | read-write | deprecated | :Reserved |
| 1.3.6.1.4.1.20044.26.9.3 | Nodepm1005CfgLabels | |||
| 1.3.6.1.4.1.20044.26.9.3.1 | Tablepm1005CfgLabelclientTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.26.9.3.1.1 | Rowpm1005CfgLabelclientEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.26.9.3.1.1.1 | Columnpm1005CfgLabelclientIndex | read-only | current | Index definition for the labelclient table |
| 1.3.6.1.4.1.20044.26.9.3.1.1.3 | Columnpm1005CfgLabelclientPortn | read-write | current | Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. |
| 1.3.6.1.4.1.20044.26.9.3.2 | Tablepm1005CfgLabellineTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.26.9.3.2.1 | Rowpm1005CfgLabellineEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.26.9.3.2.1.1 | Columnpm1005CfgLabellineIndex | read-only | current | Index definition for the labelline table |
| 1.3.6.1.4.1.20044.26.9.3.2.1.3 | Columnpm1005CfgLabellinePortn | read-write | current | Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. |
| 1.3.6.1.4.1.20044.26.9.4 | Nodepm1005CfgStartuptlh | |||
| 1.3.6.1.4.1.20044.26.9.4.1 | Tablepm1005CfgOtxtlhTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.26.9.4.1.1 | Rowpm1005CfgOtxtlhEntry | not-accessible | current | Row definition for the startuptlh table |
| 1.3.6.1.4.1.20044.26.9.4.1.1.1 | Columnpm1005CfgOtxtlhIndex | read-only | current | Index definition for the otxtlh table |
| 1.3.6.1.4.1.20044.26.9.4.1.1.3 | Columnpm1005CfgNuPortn | read-write | deprecated | : |
| 1.3.6.1.4.1.20044.26.9.4.1.1.4 | Columnpm1005CfgLineDitherRatePortn | read-write | current | Default Line OTX TLH FM amplitude :This register configures the start-up width of the frequency modulation of the Line OTX TLH |
| 1.3.6.1.4.1.20044.26.9.4.1.1.5 | Columnpm1005CfgLineDitherFhzPortn | read-write | current | Default Line OTX TLH FM frequency :This register configures the start-up frequency of the frequency modulation of the Line OTX TLH |
| 1.3.6.1.4.1.20044.26.9.4.1.1.6 | Columnpm1005CfgLinePwrLaserPortn | read-write | current | Defaut Line OTX TLH output Power :This register configures the start-up output power of the Line OTX TLH (Unit = dBm) |
| 1.3.6.1.4.1.20044.26.9.4.1.1.7 | Columnpm1005CfgLineFCurrentPortn | read-write | current | Default Line OTX TLH Channel :This register configures the start-up laser channel of the Line OTX TLH |
| 1.3.6.1.4.1.20044.26.9.4.1.1.8 | Columnpm1005CfgLineGridCurrentPortn | read-write | current | Default Line OTX TLH Grid :This register configures the start-up laser grid of the Line OTX TLH |
| 1.3.6.1.4.1.20044.26.9.4.1.1.9 | Columnpm1005CfgFPortn | read-write | current | Default Line OTX TLH lowest Freq :This register configures the start-up lowest frequency supported on the Line OTX TLH |
| 1.3.6.1.4.1.20044.26.9.4.1.1.10 | Columnpm1005CfgReservedPortn | read-write | deprecated | : |
| 1.3.6.1.4.1.20044.26.9.4.1.1.11 | Columnpm1005CfgLinePhotodiodeModePortn | read-write | current | Default Line OTX TLH APD mode :This register configures the start-up APD mode of the Line OTX TLH |
| 1.3.6.1.4.1.20044.26.9.4.1.1.12 | Columnpm1005CfgLinePhotodiodeValuePortn | read-write | current | Default Line OTX TLH APD atten. :This register configures the start-up APD attenuation on the Line OTX TLH |
| 1.3.6.1.4.1.20044.26.9.5 | Nodepm1005CfgStartuptablefive | |||
| 1.3.6.1.4.1.20044.26.9.5.1 | Tablepm1005CfgOtxtlhcapabilitiesTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.26.9.5.1.1 | Rowpm1005CfgOtxtlhcapabilitiesEntry | not-accessible | current | Row definition for the startuptablefive table |
| 1.3.6.1.4.1.20044.26.9.5.1.1.1 | Columnpm1005CfgOtxtlhcapabilitiesIndex | read-only | current | Index definition for the otxtlhcapabilities table |
| 1.3.6.1.4.1.20044.26.9.5.1.1.3 | Columnpm1005CfgComponentTypePortn | read-only | current | Component parameters :This OID defines the component parameters |
| 1.3.6.1.4.1.20044.26.9.5.1.1.4 | Columnpm1005CfgMiscellaneousPortn | read-only | current | Miscellaneous default settings :This OID defines the miscellaneous parameters |
| 1.3.6.1.4.1.20044.26.9.5.1.1.5 | Columnpm1005CfgFirstChannelPortn | read-only | current | Number of the first channel of the component :This OID defines the first channel number of the PM |
| 1.3.6.1.4.1.20044.26.9.5.1.1.6 | Columnpm1005CfgLastChannelPortn | read-only | current | Number of the last channel of the component :This OID defines the last channel number of the PM |
| 1.3.6.1.4.1.20044.26.9.5.1.1.7 | Columnpm1005CfgGridPortn | read-only | current | Grid value of the component :This OID defines the grid of the PM |
| 1.3.6.1.4.1.20044.26.9.257 | Scalarpm1005CfgWriteConfiguration | read-write | current | Write configuration to module:This OID writes the complete configuration to the module |
| 1.3.6.1.4.1.20044.26.10 | Nodepm1005traps | |||
| 1.3.6.1.4.1.20044.26.10.2 | Scalarpm1005trapPortNumber | read-only | current | Last port which generates a trap |
| 1.3.6.1.4.1.20044.26.10.3 | Scalarpm1005trapLineNumber | read-only | current | Last Line which generates a trap |
| 1.3.6.1.4.1.20044.26.10.4 | Scalarpm1005trapBoardNumber | read-only | current | Last module which generates a trap |
| 1.3.6.1.4.1.20044.26.10.30 | Notificationpm1005LineTrapNotUrgentGoesOn | current | Not urgent Line default is activated | |
| 1.3.6.1.4.1.20044.26.10.31 | Notificationpm1005LineTrapNotUrgentGoesOff | current | Not urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.26.10.32 | Notificationpm1005LineTrapUrgentGoesOn | current | Urgent Line default is activated | |
| 1.3.6.1.4.1.20044.26.10.33 | Notificationpm1005LineTrapUrgentGoesOff | current | Urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.26.10.34 | Notificationpm1005LineTrapCritGoesOn | current | Critical Line default is activated | |
| 1.3.6.1.4.1.20044.26.10.35 | Notificationpm1005LineTrapCritGoesOff | current | Critical Line default disappeared | |
| 1.3.6.1.4.1.20044.26.10.40 | Notificationpm1005ClientTrapNotUrgentGoesOn | current | Not urgent client default is activated | |
| 1.3.6.1.4.1.20044.26.10.41 | Notificationpm1005ClientTrapNotUrgentGoesOff | current | Not urgent client default disappeared | |
| 1.3.6.1.4.1.20044.26.10.42 | Notificationpm1005ClientTrapUrgentGoesOn | current | Urgent client default is activated | |
| 1.3.6.1.4.1.20044.26.10.43 | Notificationpm1005ClientTrapUrgentGoesOff | current | Urgent client default disappeared | |
| 1.3.6.1.4.1.20044.26.10.44 | Notificationpm1005ClientTrapCritGoesOn | current | Critical client default is activated | |
| 1.3.6.1.4.1.20044.26.10.45 | Notificationpm1005ClientTrapCritGoesOff | current | Critical client default disappeared | |
| 1.3.6.1.4.1.20044.26.10.50 | Notificationpm1005PowerTrapUrgentGoesOn | current | Urgent power supply default is activated | |
| 1.3.6.1.4.1.20044.26.10.51 | Notificationpm1005PowerTrapUrgentGoesOff | current | Urgent power supply default disappeared | |
| 1.3.6.1.4.1.20044.26.11 | Nodepm1005Monitoring | |||
| 1.3.6.1.4.1.20044.26.11.1 | Nodepm1005MonOther | |||
| 1.3.6.1.4.1.20044.26.11.1.3 | Nodepm1005MonRmon | |||
| 1.3.6.1.4.1.20044.26.11.1.3.359 | Scalarpm1005MonCountersReset | read-write | current | RMON Counters Reset:This OID resets and restarts all the RMON counters |
| 1.3.6.1.4.1.20044.26.11.1.3.360 | Scalarpm1005MonCountersStop | read-write | current | RMON Counters stop:This OID stops all the RMON counters |
| 1.3.6.1.4.1.20044.26.11.2 | Nodepm1005MonClient | |||
| 1.3.6.1.4.1.20044.26.11.2.4 | Nodepm1005MonClientRmonCounter | |||
| 1.3.6.1.4.1.20044.26.11.2.4.16 | Tablepm1005MonupRmonByteCntTable | not-accessible | current | List of pm1005MonupRmonByteCnt Article |
| 1.3.6.1.4.1.20044.26.11.2.4.16.1 | Rowpm1005MonupRmonByteCntEntry | not-accessible | current | Row definition for the pm1005MonupRmonByteCnt table |
| 1.3.6.1.4.1.20044.26.11.2.4.16.1.1 | Columnpm1005MonupRmonByteCntIndex | read-only | current | Index definition for the pm1005MonupRmonByteCnt table |
| 1.3.6.1.4.1.20044.26.11.2.4.16.1.2 | Columnpm1005MonupRmonByteCntValuePortn | read-only | current | Client Input Bytes :This counter is increased each time a data byte is received on the client port |
| 1.3.6.1.4.1.20044.26.11.2.4.16.1.3 | Columnpm1005MonupRmonByteCntErrorPortn | read-only | current | Bytes Counter Error :This OID when set indicates the Bytes counter value is invalid on clinet port |
| 1.3.6.1.4.1.20044.26.11.2.4.16.1.4 | Columnpm1005MonupRmonByteCntOverloadPortn | read-only | current | Bytes Counter Overload :This OID when set indicates a Bytes counter overload on client port |
| 1.3.6.1.4.1.20044.26.11.2.4.24 | Tablepm1005MonupRmonCrcErrorCntTable | not-accessible | current | List of pm1005MonupRmonCrcErrorCnt Article |
| 1.3.6.1.4.1.20044.26.11.2.4.24.1 | Rowpm1005MonupRmonCrcErrorCntEntry | not-accessible | current | Row definition for the pm1005MonupRmonCrcErrorCnt table |
| 1.3.6.1.4.1.20044.26.11.2.4.24.1.1 | Columnpm1005MonupRmonCrcErrorCntIndex | read-only | current | Index definition for the pm1005MonupRmonCrcErrorCnt table |
| 1.3.6.1.4.1.20044.26.11.2.4.24.1.2 | Columnpm1005MonupRmonCrcErrorCntValuePortn | read-only | current | Client Input CRC Errors :This counter is increased each time a CRC error is detected on the client port |
| 1.3.6.1.4.1.20044.26.11.2.4.24.1.3 | Columnpm1005MonupRmonCrcErrorCntErrorPortn | read-only | current | CRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on clinet port |
| 1.3.6.1.4.1.20044.26.11.2.4.24.1.4 | Columnpm1005MonupRmonCrcErrorCntOverloadPortn | read-only | current | CRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on client port |
| 1.3.6.1.4.1.20044.26.11.2.4.32 | Tablepm1005MonupRmonPacketsCntTable | not-accessible | current | List of pm1005MonupRmonPacketsCnt Article |
| 1.3.6.1.4.1.20044.26.11.2.4.32.1 | Rowpm1005MonupRmonPacketsCntEntry | not-accessible | current | Row definition for the pm1005MonupRmonPacketsCnt table |
| 1.3.6.1.4.1.20044.26.11.2.4.32.1.1 | Columnpm1005MonupRmonPacketsCntIndex | read-only | current | Index definition for the pm1005MonupRmonPacketsCnt table |
| 1.3.6.1.4.1.20044.26.11.2.4.32.1.2 | Columnpm1005MonupRmonPacketsCntValuePortn | read-only | current | Client Input Packets :This counter is increased each time a packet is received on the client port |
| 1.3.6.1.4.1.20044.26.11.2.4.32.1.3 | Columnpm1005MonupRmonPacketsCntErrorPortn | read-only | current | Packets Counter Error :This OID when set indicates the Packets counter value is invalid on clinet port |
| 1.3.6.1.4.1.20044.26.11.2.4.32.1.4 | Columnpm1005MonupRmonPacketsCntOverloadPortn | read-only | current | Packets Counter Overload :This OID when set indicates a Packets counter overload on client port |
| 1.3.6.1.4.1.20044.26.11.2.4.40 | Tablepm1005MonupRmonBroadcastCntTable | not-accessible | current | List of pm1005MonupRmonBroadcastCnt Article |
| 1.3.6.1.4.1.20044.26.11.2.4.40.1 | Rowpm1005MonupRmonBroadcastCntEntry | not-accessible | current | Row definition for the pm1005MonupRmonBroadcastCnt table |
| 1.3.6.1.4.1.20044.26.11.2.4.40.1.1 | Columnpm1005MonupRmonBroadcastCntIndex | read-only | current | Index definition for the pm1005MonupRmonBroadcastCnt table |
| 1.3.6.1.4.1.20044.26.11.2.4.40.1.2 | Columnpm1005MonupRmonBroadcastCntValuePortn | read-only | current | Client Input Broadcast Packets :This counter is increased each time a broadcast packet is received on the client port |
| 1.3.6.1.4.1.20044.26.11.2.4.40.1.3 | Columnpm1005MonupRmonBroadcastCntErrorPortn | read-only | current | Broadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on clinet port |
| 1.3.6.1.4.1.20044.26.11.2.4.40.1.4 | Columnpm1005MonupRmonBroadcastCntOverloadPortn | read-only | current | Broadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port |
| 1.3.6.1.4.1.20044.26.11.2.4.48 | Tablepm1005MonupRmonMulticastCntTable | not-accessible | current | List of pm1005MonupRmonMulticastCnt Article |
| 1.3.6.1.4.1.20044.26.11.2.4.48.1 | Rowpm1005MonupRmonMulticastCntEntry | not-accessible | current | Row definition for the pm1005MonupRmonMulticastCnt table |
| 1.3.6.1.4.1.20044.26.11.2.4.48.1.1 | Columnpm1005MonupRmonMulticastCntIndex | read-only | current | Index definition for the pm1005MonupRmonMulticastCnt table |
| 1.3.6.1.4.1.20044.26.11.2.4.48.1.2 | Columnpm1005MonupRmonMulticastCntValuePortn | read-only | current | Client Input Multicast Packets :This counter is increased each time a Multicast packet is received on the client port |
| 1.3.6.1.4.1.20044.26.11.2.4.48.1.3 | Columnpm1005MonupRmonMulticastCntErrorPortn | read-only | current | Multicast Counter Error :This OID when set indicates the Multicast counter value is invalid on clinet port |
| 1.3.6.1.4.1.20044.26.11.2.4.48.1.4 | Columnpm1005MonupRmonMulticastCntOverloadPortn | read-only | current | Multicast Counter Overload :This OID when set indicates a Multicast counter overload on client port |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| Pm1005AdjustValue | INTEGER { otxadjustvalue0(0), otxadjustvalue1(1), otxadjustvalue2(2), otxadjustvalue3(3), otxadjustvalue4(4), otxadjustvalue5(5), otxadjustvalue6(6), otxadjustvalue7(7), otxadjustvalue8(8), otxadjustvalue9(9), otxadjustvalue10(10) } | current | Different values in Adjust mode on OTX-TLH on line ports |
| Pm1005OtxChannel | INTEGER | current | Channel selection on OTX-TLH on line ports |
| Pm1005OtxGrid | INTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50) } | current | Different grids on OTX-TLH on line ports |
| Pm1005OtxMode | INTEGER { otx80mode(1), otx60mode(2), otxadjustmode(4) } | current | Different modes on OTX-TLH on line ports |