MIB for managing Ekinops modules with PM1008 software
OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.3IdentitymodulePm1008MIB for managing Ekinops modules with PM1008 software
1.3.6.1.4.1.20044.3.2Nodepm1008alarms
1.3.6.1.4.1.20044.3.2.1Nodepm1008AlmOther
1.3.6.1.4.1.20044.3.2.1.1Nodepm1008AlmOtherNurg
1.3.6.1.4.1.20044.3.2.1.1.2Nodepm1008AlmsynthAlm2
1.3.6.1.4.1.20044.3.2.1.1.2.1Scalarpm1008AlmConfTableSaveread-onlycurrentPM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> other…
1.3.6.1.4.1.20044.3.2.1.1.2.2Scalarpm1008AlmInvUploadread-onlycurrentInventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> other (1) <Alarmtype> other (1) <Polarit…
1.3.6.1.4.1.20044.3.2.1.1.2.3Scalarpm1008AlmConfTableLoadread-onlycurrentPM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> other (1) <Alarmt…
1.3.6.1.4.1.20044.3.2.1.1.2.4Scalarpm1008AlmCorrelatOffread-onlycurrentNot Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> other (1) <Alarmtype> other (1) <Pol…
1.3.6.1.4.1.20044.3.2.1.1.2.5Scalarpm1008AlmMaintenanceOnread-onlycurrentMaintenance Mode :This OID indicates that the PM is in maintenance mode. <Help> This alarm indicates that the maintenance mode is enabled on the PM <Condtype> …
1.3.6.1.4.1.20044.3.2.1.2Nodepm1008AlmOtherUrg
1.3.6.1.4.1.20044.3.2.1.2.194Nodepm1008AlmmodInitFailLevel2
1.3.6.1.4.1.20044.3.2.1.2.194.1Scalarpm1008AlmLedFailread-onlycurrentLed Fail :This OID indicates that Led register has not been correctly initalized <Help> This alarm indicates if the module LEDs are correctly initialized <Cond…
1.3.6.1.4.1.20044.3.2.1.2.194.2Scalarpm1008AlmNextColdBootForcedread-onlycurrentNext Cold Boot Forced :This OID indicates that the next Reset will be forced Cold <Help> This alarm indicates that the next reset of the module will be forced …
1.3.6.1.4.1.20044.3.2.1.2.194.3Scalarpm1008AlmBootUndoneread-onlycurrentBoot Undone :This OID indicates that the boot has not been correctly achieved <Help> This alarm indicates if the module has correctly boot <Condtype> BOOT_UNDO…
1.3.6.1.4.1.20044.3.2.1.2.194.4Scalarpm1008AlmResetHwInitFailread-onlycurrentReset HW Init Fail :This OID indicates that the HW intialization has caused unknown intial conditions <Help> This alarm indicates if the HW has been correctly …
1.3.6.1.4.1.20044.3.2.1.2.194.5Scalarpm1008AlmSwInitFailread-onlycurrentSW Init Fail :This OID indicates that the SW intialization has caused unknown intial conditions <Help> This alarm indicates if the SW module is correctly initi…
1.3.6.1.4.1.20044.3.2.1.2.195Nodepm1008AlmmodInitFailLevel3
1.3.6.1.4.1.20044.3.2.1.2.195.1Scalarpm1008AlmGwIdentFailread-onlycurrentGW Ident Fail :This OID indicates that GW identification has not been read <Help> This alarm indicates if the GW has been correctly identified <Condtype> GW_ID…
1.3.6.1.4.1.20044.3.2.1.2.195.2Scalarpm1008AlmObmTypeReadFailread-onlycurrentOBM Type Read Fail :This OID indicates that OBM type has not been recognized <Help> This alarm indicates if the OBM board has been correctly identified <Condty…
1.3.6.1.4.1.20044.3.2.1.2.195.3Scalarpm1008AlmInitModuleFailread-onlycurrentInit Module Fail :This OID indicates that the Module has not been correctly initialized <Help> This alarm indicates if the SW module is correctly initialized <…
1.3.6.1.4.1.20044.3.2.1.2.195.5Scalarpm1008AlmXfp1InitFailread-onlycurrentXFP1 Init Fail :This OID indicates that the XFP has not been correctly initialized <Help> This alarm indicates if the line transceiver 1 is correctly initializ…
1.3.6.1.4.1.20044.3.2.1.2.195.6Scalarpm1008AlmXfp2InitFailread-onlycurrentXFP2 Init Fail :This OID indicates that the XFP has not been correctly initialized <Help> This alarm indicates if the line transceiver 2 is correctly initializ…
1.3.6.1.4.1.20044.3.2.1.2.195.7Scalarpm1008AlmLine1InitFailread-onlycurrentLine1 Init Fail :This OID indicates that the Line registersvsubset has not been correctly initialized <Help> This alarm indicates if the line port 1 is correct…
1.3.6.1.4.1.20044.3.2.1.2.195.8Scalarpm1008AlmLine2InitFailread-onlycurrentLine2 Init Fail :This OID indicates that the Line register subset has not been correctly initialized <Help> This alarm indicates if the line port 2 is correctl…
1.3.6.1.4.1.20044.3.2.1.2.195.9Scalarpm1008AlmClient1InitFailread-onlycurrentClient1 Init Fail :This OID indicates that Client 1 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 1 is cor…
1.3.6.1.4.1.20044.3.2.1.2.195.10Scalarpm1008AlmClient2InitFailread-onlycurrentClient2 Init Fail :This OID indicates that Client 2 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 2 is cor…
1.3.6.1.4.1.20044.3.2.1.2.195.11Scalarpm1008AlmClient3InitFailread-onlycurrentClient3 Init Fail :This OID indicates that Client 3 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 3 is cor…
1.3.6.1.4.1.20044.3.2.1.2.195.12Scalarpm1008AlmClient4InitFailread-onlycurrentClient4 Init Fail :This OID indicates that Client 4 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 4 is cor…
1.3.6.1.4.1.20044.3.2.1.2.195.13Scalarpm1008AlmClient5InitFailread-onlycurrentClient5 Init Fail :This OID indicates that Client 5 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 5 is cor…
1.3.6.1.4.1.20044.3.2.1.2.195.14Scalarpm1008AlmClient6InitFailread-onlycurrentClient6 Init Fail :This OID indicates that Client 6 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 6 is cor…
1.3.6.1.4.1.20044.3.2.1.2.195.15Scalarpm1008AlmClient7InitFailread-onlycurrentClient7 Init Fail :This OID indicates that Client 7 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 7 is cor…
1.3.6.1.4.1.20044.3.2.1.2.195.16Scalarpm1008AlmClient8InitFailread-onlycurrentClient8 Init Fail :This OID indicates that Client 8 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 8 is cor…
1.3.6.1.4.1.20044.3.2.1.3Nodepm1008AlmOtherCrit
1.3.6.1.4.1.20044.3.2.1.3.0Nodepm1008AlmsynthAlm0
1.3.6.1.4.1.20044.3.2.1.3.0.9Scalarpm1008AlmModGlobFailread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the PM <Condtype> MOD_GLOB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> sy…
1.3.6.1.4.1.20044.3.2.1.3.0.15Scalarpm1008AlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.3.2.1.3.0.16Scalarpm1008AlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.3.2.2Nodepm1008AlmClient
1.3.6.1.4.1.20044.3.2.2.1Nodepm1008AlmClientNurg
1.3.6.1.4.1.20044.3.2.2.1.48Tablepm1008AlmsfpWarnDdmTablenot-accessiblecurrentList of pm1008AlmsfpWarnDdm Article
1.3.6.1.4.1.20044.3.2.2.1.48.1Rowpm1008AlmsfpWarnDdmEntrynot-accessiblecurrentRow definition for the pm1008AlmsfpWarnDdm table
1.3.6.1.4.1.20044.3.2.2.1.48.1.1Columnpm1008AlmsfpWarnDdmIndexread-onlycurrentIndex definition for the pm1008AlmsfpWarnDdm table
1.3.6.1.4.1.20044.3.2.2.1.48.1.2Columnpm1008AlmTxPwLowWngPortnread-onlycurrentClient SFP Tx Power Low Warning :Warning indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> TX…
1.3.6.1.4.1.20044.3.2.2.1.48.1.3Columnpm1008AlmTxPwrHighWngPortnread-onlycurrentClient SFP Tx Power High Warning :Warning indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.3.2.2.1.48.1.4Columnpm1008AlmTxBiasLowWngPortnread-onlycurrentClient SFP Bias Low Warning :Warning indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.3.2.2.1.48.1.5Columnpm1008AlmTxBiasHighWngPortnread-onlycurrentClient SFP Bias High Warning :Warning indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.3.2.2.1.48.1.6Columnpm1008AlmVccLowWngPortnread-onlycurrentClient SFP Power Supply Low Warning :Warning indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.3.2.2.1.48.1.7Columnpm1008AlmVccHighWngPortnread-onlycurrentClient SFP Power Supply High Warning :Warning indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condty…
1.3.6.1.4.1.20044.3.2.2.1.48.1.8Columnpm1008AlmTempLowWngPortnread-onlycurrentClient SFP Temp Low Warning :Warning indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> TEMP_LO…
1.3.6.1.4.1.20044.3.2.2.1.48.1.9Columnpm1008AlmTempHighWngPortnread-onlycurrentClient SFP Temp High Warning :Warning indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> TEMP_…
1.3.6.1.4.1.20044.3.2.2.1.48.1.16Columnpm1008AlmRxPwrLowWngPortnread-onlycurrentClient SFP Rx Power Low Warning :Warning indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> RX_…
1.3.6.1.4.1.20044.3.2.2.1.48.1.17Columnpm1008AlmRxPwrHighWngPortnread-onlycurrentClient SFP Rx Power High Warning :Warning indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> R…
1.3.6.1.4.1.20044.3.2.2.2Nodepm1008AlmClientUrg
1.3.6.1.4.1.20044.3.2.2.2.32Tablepm1008AlmsfpAlmDdmTablenot-accessiblecurrentList of pm1008AlmsfpAlmDdm Article
1.3.6.1.4.1.20044.3.2.2.2.32.1Rowpm1008AlmsfpAlmDdmEntrynot-accessiblecurrentRow definition for the pm1008AlmsfpAlmDdm table
1.3.6.1.4.1.20044.3.2.2.2.32.1.1Columnpm1008AlmsfpAlmDdmIndexread-onlycurrentIndex definition for the pm1008AlmsfpAlmDdm table
1.3.6.1.4.1.20044.3.2.2.2.32.1.2Columnpm1008AlmTxPwrLowAlaPortnread-onlycurrentClient SFP Tx Power Low :Alarm indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> TX_PWR_LOW_A…
1.3.6.1.4.1.20044.3.2.2.2.32.1.3Columnpm1008AlmTxPwrHighAlaPortnread-onlycurrentClient SFP Tx Power High :Alarm indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> TX_PWR_HIG…
1.3.6.1.4.1.20044.3.2.2.2.32.1.4Columnpm1008AlmTxBiasLowAlaPortnread-onlycurrentClient SFP Bias Low :Alarm indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> TX_BIAS_LO…
1.3.6.1.4.1.20044.3.2.2.2.32.1.5Columnpm1008AlmTxBiasHighAlaPortnread-onlycurrentClient SFP Bias High :Alarm indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype> TX_BIAS_…
1.3.6.1.4.1.20044.3.2.2.2.32.1.6Columnpm1008AlmVccLowAlaPortnread-onlycurrentClient SFP Power Supply Low :Alarm indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype> VCC_LOW_…
1.3.6.1.4.1.20044.3.2.2.2.32.1.7Columnpm1008AlmVccHighAlaPortnread-onlycurrentClient SFP Power Supply High :Alarm indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condtype> VCC_HI…
1.3.6.1.4.1.20044.3.2.2.2.32.1.8Columnpm1008AlmTempLowAlaPortnread-onlycurrentClient SFP Temp Low :Alarm indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> TEMP_LOW_ALA_1 <P…
1.3.6.1.4.1.20044.3.2.2.2.32.1.9Columnpm1008AlmTempHighAlaPortnread-onlycurrentClient SFP Temp High :Alarm indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> TEMP_HIGH_ALA_1…
1.3.6.1.4.1.20044.3.2.2.2.32.1.16Columnpm1008AlmRxPwrLowAlaPortnread-onlycurrentClient SFP Rx Power Low :Alarm indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> RX_PWR_LOW_AL…
1.3.6.1.4.1.20044.3.2.2.2.32.1.17Columnpm1008AlmRxPwrHighAlaPortnread-onlycurrentClient SFP Rx Power High :Alarm indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> RX_PWR_HIGH…
1.3.6.1.4.1.20044.3.2.2.3Nodepm1008AlmClientCrit
1.3.6.1.4.1.20044.3.2.2.3.8Tablepm1008AlmsynthAlmPortTablenot-accessiblecurrentList of pm1008AlmsynthAlmPort Article
1.3.6.1.4.1.20044.3.2.2.3.8.1Rowpm1008AlmsynthAlmPortEntrynot-accessiblecurrentRow definition for the pm1008AlmsynthAlmPort table
1.3.6.1.4.1.20044.3.2.2.3.8.1.1Columnpm1008AlmsynthAlmPortIndexread-onlycurrentIndex definition for the pm1008AlmsynthAlmPort table
1.3.6.1.4.1.20044.3.2.2.3.8.1.2Columnpm1008AlmSfpAbsentPortnread-onlycurrentClient SFP Absent :This OID indicates that the SFP module is not present in the client port. <Help> This alarm indicates if the client transceiver is present. …
1.3.6.1.4.1.20044.3.2.2.3.8.1.3Columnpm1008AlmDdmAbsentPortnread-onlycurrentDDM Supported On Client SFP :This OID indicates that the Client SFP module supports the Digital Diagnostic Monitoring function <Help> This status indicates if …
1.3.6.1.4.1.20044.3.2.2.3.8.1.5Columnpm1008AlmHwFailAccPortnread-onlycurrentClient HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Condtype> HW_FAIL_ACC_1 <Probcause> equipmentMalfunction (16)…
1.3.6.1.4.1.20044.3.2.2.3.8.1.6Columnpm1008AlmDwLsdPortnread-onlycurrentClient SFP Laser Shutdown :This OID indicates the Client SFP transmitter output is ON. <Help> This status indicates if the client transceiver laser is ON or OF…
1.3.6.1.4.1.20044.3.2.2.3.8.1.7Columnpm1008AlmClientLocalOosPortnread-onlycurrentLocal Client Port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local c…
1.3.6.1.4.1.20044.3.2.2.3.8.1.8Columnpm1008AlmClientRemoteOosPortnread-onlycurrentRemote Client Port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the remot…
1.3.6.1.4.1.20044.3.2.2.3.8.1.9Columnpm1008AlmDwCaisPortnread-onlycurrentClient AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indictaes if a Client Alarm Indication Signal is…
1.3.6.1.4.1.20044.3.2.2.3.8.1.10Columnpm1008AlmSfpDdmWarningPortnread-onlycurrentWarning On Client SFP DDM :This OID indicates a warning is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Warning has been detecte…
1.3.6.1.4.1.20044.3.2.2.3.8.1.11Columnpm1008AlmSfpDdmAlmPortnread-onlycurrentAlarm On Client SFP DDM :This OID indicates an alarm is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Alarm has been detected on …
1.3.6.1.4.1.20044.3.2.2.3.8.1.13Columnpm1008AlmFailAccPortnread-onlycurrentClient Access Fail :This OID indicates a failure on the Client port <Condtype> FAIL_ACC_1 <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12)…
1.3.6.1.4.1.20044.3.2.2.3.8.1.17Columnpm1008AlmUpCsfPortnread-onlycurrentClient Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu…
1.3.6.1.4.1.20044.3.2.2.3.16Tablepm1008AlmaccessioAlmTablenot-accessiblecurrentList of pm1008AlmaccessioAlm Article
1.3.6.1.4.1.20044.3.2.2.3.16.1Rowpm1008AlmaccessioAlmEntrynot-accessiblecurrentRow definition for the pm1008AlmaccessioAlm table
1.3.6.1.4.1.20044.3.2.2.3.16.1.1Columnpm1008AlmaccessioAlmIndexread-onlycurrentIndex definition for the pm1008AlmaccessioAlm table
1.3.6.1.4.1.20044.3.2.2.3.16.1.2Columnpm1008AlmDwLasFailPortnread-onlycurrentClient SFP Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the client port (this alarm reports the transmitter failure alarm …
1.3.6.1.4.1.20044.3.2.2.3.16.1.5Columnpm1008AlmUpLosPortnread-onlycurrentClient Input Loss Of Signal :This OID indicates that no signal is present on the SFP of the client port <Help> This alarm indicates if an optical signal is det…
1.3.6.1.4.1.20044.3.2.2.3.72Tablepm1008AlmmapperDeAlmTablenot-accessiblecurrentList of pm1008AlmmapperDeAlm Article
1.3.6.1.4.1.20044.3.2.2.3.72.1Rowpm1008AlmmapperDeAlmEntrynot-accessiblecurrentRow definition for the pm1008AlmmapperDeAlm table
1.3.6.1.4.1.20044.3.2.2.3.72.1.1Columnpm1008AlmmapperDeAlmIndexread-onlycurrentIndex definition for the pm1008AlmmapperDeAlm table
1.3.6.1.4.1.20044.3.2.2.3.72.1.2Columnpm1008AlmUpAccOosPortnread-onlycurrentClient Loss Of 10b/8b Synchro :This OID indicates the upstream client input port has lost synchronization on its 10B/8B decoder <Help> This alarms indicates if…
1.3.6.1.4.1.20044.3.2.2.3.72.1.11Columnpm1008AlmUpBufferOvlPortnread-onlycurrentClient Upstream Buffer Overload :This OID indicates that the rate adaptation buffer for client port is in overload. <Help> This alarm indicates if there is a u…
1.3.6.1.4.1.20044.3.2.2.3.72.1.12Columnpm1008AlmDwCsfDetPortnread-onlycurrentClient Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client…
1.3.6.1.4.1.20044.3.2.2.3.72.1.15Columnpm1008AlmDwBufferOvlPortnread-onlycurrentClient Downstream Buffer Overload :This OID indicates that the de-mapper buffer for client port is in overload. <Help> This alarm indicates if there is a downs…
1.3.6.1.4.1.20044.3.2.3Nodepm1008AlmLine
1.3.6.1.4.1.20044.3.2.3.1Nodepm1008AlmLineNurg
1.3.6.1.4.1.20044.3.2.3.1.209Tablepm1008AlmlineXfp1WarningsTablenot-accessiblecurrentList of pm1008AlmlineXfp1Warnings Article
1.3.6.1.4.1.20044.3.2.3.1.209.1Rowpm1008AlmlineXfp1WarningsEntrynot-accessiblecurrentRow definition for the pm1008AlmlineXfp1Warnings table
1.3.6.1.4.1.20044.3.2.3.1.209.1.1Columnpm1008AlmlineXfp1WarningsIndexread-onlycurrentIndex definition for the pm1008AlmlineXfp1Warnings table
1.3.6.1.4.1.20044.3.2.3.1.209.1.2Columnpm1008AlmTxPowerLowWarningPortnread-onlycurrentLine Optical Tx Power Low Warning :Warning indicating that the XFP/OTX transmitter transmitter output power is lower than the threshold value written in the XF…
1.3.6.1.4.1.20044.3.2.3.1.209.1.3Columnpm1008AlmTxPowerHighWarningPortnread-onlycurrentLine Optical Tx Power High Warning :Warning indicating that the XFP/OTX transmitter transmitter output power is higher than the threshold value written in the …
1.3.6.1.4.1.20044.3.2.3.1.209.1.4Columnpm1008AlmTxBiasLowWarningPortnread-onlycurrentLine Transceiver Bias Low Warning :Warning indicating that the XFP/OTX transmitter laser bias current is lower than the threshold value written in the XFP/OTX …
1.3.6.1.4.1.20044.3.2.3.1.209.1.5Columnpm1008AlmTxBiasHighWarningPortnread-onlycurrentLine Transceiver Bias High Warning :Warning indicating that the XFP/OTX transmitter laser bias current is higher than the threshold value written in the XFP EE…
1.3.6.1.4.1.20044.3.2.3.1.209.1.8Columnpm1008AlmTempLowWarningPortnread-onlycurrentLine Transceiver Temp Low Warning :Warning indicating that the XFP/OTX temperature is lower than the threshold value written in the XFP/OTX EEPROM <Condtype> T…
1.3.6.1.4.1.20044.3.2.3.1.209.1.9Columnpm1008AlmTempHighWarningPortnread-onlycurrentLine Transceiver Temp High Warning :Warning indicating that the XFP/OTX temperature is higher than the threshold value written in the XFP EEPROM <Condtype> TEM…
1.3.6.1.4.1.20044.3.2.3.1.209.1.16Columnpm1008AlmRxPowerLowWarningPortnread-onlycurrentLine Optical Rx Power Low Warning :Warning indicating that the XFP received optical power is lower than the threshold value written in the XFP EEPROM <Condtype…
1.3.6.1.4.1.20044.3.2.3.1.209.1.17Columnpm1008AlmRxPowerHighWarningPortnread-onlycurrentLine Optical Rx Power High Warning :Warning indicating that the XFP received optical power is higher than the threshold value written in the XFP EEPROM <Condty…
1.3.6.1.4.1.20044.3.2.3.1.225Tablepm1008AlmlineOtx1TlhWarningsTablenot-accessiblecurrentList of pm1008AlmlineOtx1TlhWarnings Article
1.3.6.1.4.1.20044.3.2.3.1.225.1Rowpm1008AlmlineOtx1TlhWarningsEntrynot-accessiblecurrentRow definition for the pm1008AlmlineOtx1TlhWarnings table
1.3.6.1.4.1.20044.3.2.3.1.225.1.1Columnpm1008AlmlineOtx1TlhWarningsIndexread-onlycurrentIndex definition for the pm1008AlmlineOtx1TlhWarnings table
1.3.6.1.4.1.20044.3.2.3.1.225.1.6Columnpm1008AlmLineModulatorAgingHighWarningPortnread-onlycurrentLine Modulator Aging High Warning :Warning indicating the Line OTX TLH modulator aging is higher than the threshold written in the EEPROM <Condtype> LINE_MODUL…
1.3.6.1.4.1.20044.3.2.3.1.225.1.7Columnpm1008AlmLineAgingHighWarningPortnread-onlycurrentLine OTX TLH Aging High Warning :Warning indicating the Line OTX TLH aging is higher than the threshold written in the EEPROM <Condtype> LINE_AGING_HIGH_WARNIN…
1.3.6.1.4.1.20044.3.2.3.1.225.1.13Columnpm1008AlmLineFreqDevHighWarningPortnread-onlycurrentLine Freq. Deviation High Warning :Warning indicating the Line OTX TLH frequency deviation is higher than the threshold written in the EEPROM <Condtype> LINE_F…
1.3.6.1.4.1.20044.3.2.3.1.225.1.15Columnpm1008AlmLineLaserTempHighWarningPortnread-onlycurrentLine Laser Temp. High Warning :Warning indicating the Line OTX TLH laser temperature is higher than the threshold written in the EEPROM <Condtype> LINE_LASER_T…
1.3.6.1.4.1.20044.3.2.3.2Nodepm1008AlmLineUrg
1.3.6.1.4.1.20044.3.2.3.2.129Tablepm1008AlmdfrmBerTablenot-accessiblecurrentList of pm1008AlmdfrmBer Article
1.3.6.1.4.1.20044.3.2.3.2.129.1Rowpm1008AlmdfrmBerEntrynot-accessiblecurrentRow definition for the pm1008AlmdfrmBer table
1.3.6.1.4.1.20044.3.2.3.2.129.1.1Columnpm1008AlmdfrmBerIndexread-onlycurrentIndex definition for the pm1008AlmdfrmBer table
1.3.6.1.4.1.20044.3.2.3.2.129.1.2Columnpm1008AlmLineSignalDegradePortnread-onlycurrentCustom Line Signal Degrade :This OID indicates that the line input signal is DEGRADE. The assertion hysteresis can customized by the host <Condtype> LINE_SIGNA…
1.3.6.1.4.1.20044.3.2.3.2.129.1.3Columnpm1008AlmLineSignalFailPortnread-onlycurrentCustom Line Signal Fail :This OID indicates that the line input signal is FAIL. The assertion hysteresis can be customized by the host <Condtype> LINE_SIGNAL_F…
1.3.6.1.4.1.20044.3.2.3.2.129.1.6Columnpm1008AlmLineDegradePortnread-onlycurrentFixed Line Signal Degrade :This OID indicates that the line input signal is DEGRADE. The assetion hysteresis is fixed to 10-8 (assertion) and 10-9 (de-assertio…
1.3.6.1.4.1.20044.3.2.3.2.208Tablepm1008AlmlineXfp1AlarmTablenot-accessiblecurrentList of pm1008AlmlineXfp1Alarm Article
1.3.6.1.4.1.20044.3.2.3.2.208.1Rowpm1008AlmlineXfp1AlarmEntrynot-accessiblecurrentRow definition for the pm1008AlmlineXfp1Alarm table
1.3.6.1.4.1.20044.3.2.3.2.208.1.1Columnpm1008AlmlineXfp1AlarmIndexread-onlycurrentIndex definition for the pm1008AlmlineXfp1Alarm table
1.3.6.1.4.1.20044.3.2.3.2.208.1.2Columnpm1008AlmTxPowerLowAlarmPortnread-onlycurrentLine Optical Tx Power Low :Alarm indicating that the XFP/OTX transmitter transmitter output power is lower than the threshold value written in the XFP/OTX EEPR…
1.3.6.1.4.1.20044.3.2.3.2.208.1.3Columnpm1008AlmTxPowerHighAlarmPortnread-onlycurrentLine Optical Tx Power High :Alarm indicating that the XFP/OTX transmitter transmitter output power is higher than the threshold value written in the XFP EEPROM…
1.3.6.1.4.1.20044.3.2.3.2.208.1.4Columnpm1008AlmTxBiasLowAlarmPortnread-onlycurrentLine Transceiver Bias Low :Alarm indicating that the XFP/OTX transmitter laser bias current is lower than the threshold value written in the XFP/OTX EEPROM <Co…
1.3.6.1.4.1.20044.3.2.3.2.208.1.5Columnpm1008AlmTxBiasHighAlarmPortnread-onlycurrentLine Transceiver Bias High :Alarm indicating that the XFP/OTX transmitter laser bias current is higher than the threshold value written in the XFP EEPROM <Cond…
1.3.6.1.4.1.20044.3.2.3.2.208.1.8Columnpm1008AlmTempLowAlarmPortnread-onlycurrentLine Transceiver Temp Low :Alarm indicating that the XFP/OTX temperature is lower than the threshold value written in the XFP/OTX EEPROM <Condtype> TEMP_LOW_AL…
1.3.6.1.4.1.20044.3.2.3.2.208.1.9Columnpm1008AlmTempHighAlarmPortnread-onlycurrentLine Transceiver Temp High :Alarm indicating that the XFP/OTX temperature is higher than the threshold value written in the XFP EEPROM <Condtype> TEMP_HIGH_ALA…
1.3.6.1.4.1.20044.3.2.3.2.208.1.16Columnpm1008AlmRxPowerLowAlarmPortnread-onlycurrentLine Optical Rx Power Low :Alarm indicating that the XFP received optical power is lower than the threshold value written in the XFP EEPROM <Condtype> RX_POWER…
1.3.6.1.4.1.20044.3.2.3.2.208.1.17Columnpm1008AlmRxPowerHighAlarmPortnread-onlycurrentLine Optical Rx Power High :Alarm indicating that the XFP received optical power is higher than the threshold value written in the XFP EEPROM <Condtype> RX_POW…
1.3.6.1.4.1.20044.3.2.3.2.212Tablepm1008AlmlineXfp1SupplyAlarmTablenot-accessiblecurrentList of pm1008AlmlineXfp1SupplyAlarm Article
1.3.6.1.4.1.20044.3.2.3.2.212.1Rowpm1008AlmlineXfp1SupplyAlarmEntrynot-accessiblecurrentRow definition for the pm1008AlmlineXfp1SupplyAlarm table
1.3.6.1.4.1.20044.3.2.3.2.212.1.1Columnpm1008AlmlineXfp1SupplyAlarmIndexread-onlycurrentIndex definition for the pm1008AlmlineXfp1SupplyAlarm table
1.3.6.1.4.1.20044.3.2.3.2.212.1.2Columnpm1008AlmVee5LowAlarmPortnread-onlycurrentVEE5 Power Supply Low :Alarm indicating the XFP/OTX VEE5 power supply is lower than the threshold written in the EEPROM <Condtype> VEE5_LOW_ALARM_1 <Probcause>…
1.3.6.1.4.1.20044.3.2.3.2.212.1.3Columnpm1008AlmVee5HighAlarmPortnread-onlycurrentVEE5 Power Supply High :Alarm indicating the XFP/OTX VEE5 power supply is higher than the threshold written in the EEPROM <Condtype> VEE5_HIGH_ALARM_1 <Probcau…
1.3.6.1.4.1.20044.3.2.3.2.212.1.4Columnpm1008AlmVcc2LowAlarmPortnread-onlycurrentVCC2 Power Supply Low :Alarm indicating the XFP/OTX VCC2 power supply is lower than the threshold written in the EEPROM <Condtype> VCC2_LOW_ALARM_1 <Probcause>…
1.3.6.1.4.1.20044.3.2.3.2.212.1.5Columnpm1008AlmVcc2HighAlarmPortnread-onlycurrentVCC2 Power Supply High :Alarm indicating the XFP/OTX VCC2 power supply is higher than the threshold written in the EEPROM <Condtype> VCC2_HIGH_ALARM_1 <Probcau…
1.3.6.1.4.1.20044.3.2.3.2.212.1.6Columnpm1008AlmVcc3LowAlarmPortnread-onlycurrentVCC3 Power Supply Low :Alarm indicating the XFP/OTX VCC3 power supply is lower than the threshold written in the EEPROM <Condtype> VCC3_LOW_ALARM_1 <Probcause>…
1.3.6.1.4.1.20044.3.2.3.2.212.1.7Columnpm1008AlmVcc3HighAlarmPortnread-onlycurrentVCC3 Power Supply High :Alarm indicating the XFP/OTX VCC3 power supply is higher than the threshold written in the EEPROM <Condtype> VCC3_HIGH_ALARM_1 <Probcau…
1.3.6.1.4.1.20044.3.2.3.2.212.1.8Columnpm1008AlmVcc5LowAlarmPortnread-onlycurrentVCC5 Power Supply Low :Alarm indicating the XFP/OTX VCC5 power supply is lower than the threshold written in the EEPROM <Condtype> VCC5_LOW_ALARM_1 <Probcause>…
1.3.6.1.4.1.20044.3.2.3.2.212.1.9Columnpm1008AlmVcc5HighAlarmPortnread-onlycurrentVCC5 Power Supply High :Alarm indicating the XFP/OTX VCC5 power supply is higher than the threshold written in the EEPROM <Condtype> VCC5_HIGH_ALARM_1 <Probcau…
1.3.6.1.4.1.20044.3.2.3.2.212.1.10Columnpm1008AlmVee5LowWarningPortnread-onlycurrentVEE5 Power Supply Low Warning :Warning indicating the XFP/OTX VEE5 power supply is lower than the threshold written in the EEPROM <Condtype> VEE5_LOW_WARNING_1…
1.3.6.1.4.1.20044.3.2.3.2.212.1.11Columnpm1008AlmVee5HighWarningPortnread-onlycurrentVEE5 Power Supply High Warning :Warning indicating the XFP/OTX VEE5 power supply is higher than the threshold written in the EEPROM <Condtype> VEE5_HIGH_WARNIN…
1.3.6.1.4.1.20044.3.2.3.2.212.1.12Columnpm1008AlmVcc2LowWarningPortnread-onlycurrentVCC2 Power Supply Low Warning :Warning indicating the XFP/OTX VCC2 power supply is lower than the threshold written in the EEPROM <Condtype> VCC2_LOW_WARNING_1…
1.3.6.1.4.1.20044.3.2.3.2.212.1.13Columnpm1008AlmVcc2HighWarningPortnread-onlycurrentVCC2 Power Supply High Warning :Warning indicating the XFP/OTX VCC2 power supply is higher than the threshold written in the EEPROM <Condtype> VCC2_HIGH_WARNIN…
1.3.6.1.4.1.20044.3.2.3.2.212.1.14Columnpm1008AlmVcc3LowWarningPortnread-onlycurrentVCC3 Power Supply Low Warning :Warning indicating the XFP/OTX VCC3 power supply is lower than the threshold written in the EEPROM <Condtype> VCC3_LOW_WARNING_1…
1.3.6.1.4.1.20044.3.2.3.2.212.1.15Columnpm1008AlmVcc3HighWarningPortnread-onlycurrentVCC3 Power Supply High Warning :Warning indicating the XFP/OTX VCC3 power supply is higher than the threshold written in the EEPROM <Condtype> VCC3_HIGH_WARNIN…
1.3.6.1.4.1.20044.3.2.3.2.212.1.16Columnpm1008AlmVcc5LowWarningPortnread-onlycurrentVCC5 Power Supply Low Warning :Warning indicating the XFP/OTX VCC5 power supply is lower than the threshold written in the EEPROM <Condtype> VCC5_LOW_WARNING_1…
1.3.6.1.4.1.20044.3.2.3.2.212.1.17Columnpm1008AlmVcc5HighWarningPortnread-onlycurrentVCC5 Power Supply High Warning :Warning indicating the XFP/OTX VCC5 power supply is higher than the threshold written in the EEPROM <Condtype> VCC5_HIGH_WARNIN…
1.3.6.1.4.1.20044.3.2.3.2.224Tablepm1008AlmlineOtx1TlhAlarmsTablenot-accessiblecurrentList of pm1008AlmlineOtx1TlhAlarms Article
1.3.6.1.4.1.20044.3.2.3.2.224.1Rowpm1008AlmlineOtx1TlhAlarmsEntrynot-accessiblecurrentRow definition for the pm1008AlmlineOtx1TlhAlarms table
1.3.6.1.4.1.20044.3.2.3.2.224.1.1Columnpm1008AlmlineOtx1TlhAlarmsIndexread-onlycurrentIndex definition for the pm1008AlmlineOtx1TlhAlarms table
1.3.6.1.4.1.20044.3.2.3.2.224.1.6Columnpm1008AlmLineModulatorAgingHighAlaPortnread-onlycurrentLine Modulator Aging High Alarm :Alarm indicating the Line OTX TLH modulator aging is higher than the threshold written in the EEPROM <Condtype> LINE_MODULATOR…
1.3.6.1.4.1.20044.3.2.3.2.224.1.7Columnpm1008AlmLineAgingHighAlaPortnread-onlycurrentLine OTX TLH Aging High Alarm :Alarm indicating the Line OTX TLH aging is higher than the threshold written in the EEPROM <Condtype> LINE_AGING_HIGH_ALA_1 <Pro…
1.3.6.1.4.1.20044.3.2.3.2.224.1.13Columnpm1008AlmLineFreqDevHighAlaPortnread-onlycurrentLine Freq. Deviation High Alarm :Alarm indicating the Line OTX TLH frequency deviation is higher than the threshold written in the EEPROM <Condtype> LINE_FREQ_…
1.3.6.1.4.1.20044.3.2.3.2.224.1.15Columnpm1008AlmLineLaserTempHighAlaPortnread-onlycurrentLine Laser Temp. High Alarm :Alarm indicating the Line OTX TLH laser temperature is higher than the threshold written in the EEPROM <Condtype> LINE_LASER_TEMP_…
1.3.6.1.4.1.20044.3.2.3.3Nodepm1008AlmLineCrit
1.3.6.1.4.1.20044.3.2.3.3.7Tablepm1008AlmsynthAlmLineTablenot-accessiblecurrentList of pm1008AlmsynthAlmLine Article
1.3.6.1.4.1.20044.3.2.3.3.7.1Rowpm1008AlmsynthAlmLineEntrynot-accessiblecurrentRow definition for the pm1008AlmsynthAlmLine table
1.3.6.1.4.1.20044.3.2.3.3.7.1.1Columnpm1008AlmsynthAlmLineIndexread-onlycurrentIndex definition for the pm1008AlmsynthAlmLine table
1.3.6.1.4.1.20044.3.2.3.3.7.1.2Columnpm1008AlmXfpAbsentPortnread-onlycurrentLine Optical Module Absent :This OID indicates that the line optical interface (XFP or OTX) is not plugged in. <Help> This alarm indicates if the line transcei…
1.3.6.1.4.1.20044.3.2.3.3.7.1.3Columnpm1008AlmXfpInitNotComplPortnread-onlycurrentLine Optical Module Ready :This OID indicates that the optical interface (XFP or OTX) is not operational. <Help> This status indicates if the line transceiver …
1.3.6.1.4.1.20044.3.2.3.3.7.1.5Columnpm1008AlmLineHwFailPortnread-onlycurrentLine Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Condtype> LINE_HW_FAIL <Probcause> equipmentMalfunction (1…
1.3.6.1.4.1.20044.3.2.3.3.7.1.6Columnpm1008AlmXfpTxOffPortnread-onlycurrentLine Optical Module Laser Shutdown :This OID indicates the line optical output power is on <Help> This status indicates if the line transceiver laser is ON or …
1.3.6.1.4.1.20044.3.2.3.3.7.1.7Columnpm1008AlmLineLocalOosPortnread-onlycurrentLine Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service…
1.3.6.1.4.1.20044.3.2.3.3.7.1.9Columnpm1008AlmUpRdiInsPortnread-onlycurrentMS-RDI/L-RDI Inserted On Line :This OID indicates an upstream MS-RDI/L-RDI has been inserted in the outgoing 10 Gb/s SDH/SONET signal. <Help> This status indic…
1.3.6.1.4.1.20044.3.2.3.3.7.1.10Columnpm1008AlmLineDdmWarningPortnread-onlycurrentWarning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Warni…
1.3.6.1.4.1.20044.3.2.3.3.7.1.11Columnpm1008AlmLineDdmAlmPortnread-onlycurrentAlarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Alarm ha…
1.3.6.1.4.1.20044.3.2.3.3.7.1.13Columnpm1008AlmLineFailPortnread-onlycurrentLine Port Failure :This OID indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12) <Po…
1.3.6.1.4.1.20044.3.2.3.3.7.1.17Columnpm1008AlmLineActivePortnread-onlycurrentLine Active :This bit indicates the line #n is active on receive side <Help> This status indicates whether the line is active or standby. <Condtype> LINE_ACTIV…
1.3.6.1.4.1.20044.3.2.3.3.128Tablepm1008AlmdfrmAlmTablenot-accessiblecurrentList of pm1008AlmdfrmAlm Article
1.3.6.1.4.1.20044.3.2.3.3.128.1Rowpm1008AlmdfrmAlmEntrynot-accessiblecurrentRow definition for the pm1008AlmdfrmAlm table
1.3.6.1.4.1.20044.3.2.3.3.128.1.1Columnpm1008AlmdfrmAlmIndexread-onlycurrentIndex definition for the pm1008AlmdfrmAlm table
1.3.6.1.4.1.20044.3.2.3.3.128.1.2Columnpm1008AlmDwAisDetPortnread-onlycurrentMS-AIS/L-AIS Detected On Line Input :This OID indicates that an MS-AIS has been detected on incoming OC-48c/STM-16c input signal <Help> This alarm indicates if…
1.3.6.1.4.1.20044.3.2.3.3.128.1.3Columnpm1008AlmDwRdiDetPortnread-onlycurrentMS-RDI/L-RDI Detected On Line Input :This OID indicates that an MS-RDI has been detected on incoming OC-48c/STM-16c input signal <Help> This alarm indicates if…
1.3.6.1.4.1.20044.3.2.3.3.128.1.4Columnpm1008AlmDwOofPortnread-onlycurrentSONET/SDH Line Out Of Frame :This OID indicates that an Out Of Frame has been detected on incoming OC-48c/STM-16c input signal <Help> This alarm indicates if t…
1.3.6.1.4.1.20044.3.2.3.3.128.1.5Columnpm1008AlmDwLofPortnread-onlycurrentSONET/SDH Line Loss Of Frame :This OID indicates that a Loss Of Frame has been detected on incoming OC-48c/STM-16c input signal <Help> This alarm indicates if …
1.3.6.1.4.1.20044.3.2.3.3.128.1.15Columnpm1008AlmDccLoopbackPortnread-onlycurrentDCC Traffic Loopback :This OID indicates a loopback condition detected on DCC over the network <Help> This alarms indicates if a DCC loopback is detected. <Con…
1.3.6.1.4.1.20044.3.2.3.3.128.1.16Columnpm1008AlmRxDccBroadStormPortnread-onlycurrentRx DCC Ethernet Broadcast Storm :This OID indicates that a storm of Broadcast/Multicast packets have been detected on the DCC channel on the Receive Line side …
1.3.6.1.4.1.20044.3.2.3.3.128.1.17Columnpm1008AlmTxDccBroadStormPortnread-onlycurrentTx DCC Ethernet Broadcast Storm :This OID indicates that a storm of Broadcast/Multicast packets have been detected on the DCC channel on the Transmit Line side…
1.3.6.1.4.1.20044.3.2.3.3.133Tablepm1008AlmlineSyncAlarmsTablenot-accessiblecurrentList of pm1008AlmlineSyncAlarms Article
1.3.6.1.4.1.20044.3.2.3.3.133.1Rowpm1008AlmlineSyncAlarmsEntrynot-accessiblecurrentRow definition for the pm1008AlmlineSyncAlarms table
1.3.6.1.4.1.20044.3.2.3.3.133.1.1Columnpm1008AlmlineSyncAlarmsIndexread-onlycurrentIndex definition for the pm1008AlmlineSyncAlarms table
1.3.6.1.4.1.20044.3.2.3.3.133.1.13Columnpm1008AlmDwLockerrPortnread-onlycurrentDownstream Clock Lock Error :This OID indicates that the deserializer input 10 Gb/s clock recovery is not locked. <Condtype> DW_LOCKERR <Probcause> receiveFail…
1.3.6.1.4.1.20044.3.2.3.3.133.1.14Columnpm1008AlmUpLockerrPortnread-onlycurrentUpstream Clock Lock Error :This OID indicates that the serializer output 10 Gb/s clock multiplier unit is not locked. <Condtype> UP_LOCKERR <Probcause> receive…
1.3.6.1.4.1.20044.3.2.3.3.133.1.17Columnpm1008AlmDwLosPortnread-onlycurrentLine Input Loss Of Signal :This OID indicates a loss of signal on the 10 Gb/s input. <Help> This alarm indicates if an optical signal is detected on the line t…
1.3.6.1.4.1.20044.3.2.3.3.211Tablepm1008AlmlineXfp1AlarmsTablenot-accessiblecurrentList of pm1008AlmlineXfp1Alarms Article
1.3.6.1.4.1.20044.3.2.3.3.211.1Rowpm1008AlmlineXfp1AlarmsEntrynot-accessiblecurrentRow definition for the pm1008AlmlineXfp1Alarms table
1.3.6.1.4.1.20044.3.2.3.3.211.1.1Columnpm1008AlmlineXfp1AlarmsIndexread-onlycurrentIndex definition for the pm1008AlmlineXfp1Alarms table
1.3.6.1.4.1.20044.3.2.3.3.211.1.3Columnpm1008AlmModNrPortnread-onlycurrentLine Optical Module Not Ready :This OID indicates that the module is unable to determine correct data. <Help> This alarm indicates if the line transceiver is r…
1.3.6.1.4.1.20044.3.2.3.3.211.1.4Columnpm1008AlmRxCdrNotLockedPortnread-onlycurrentLine Optical Rx CDR Unlocked :This OID indicates that a loss of lock on the receiving side CDR has been detected <Help> This alarm indicates if the Rx CDR is l…
1.3.6.1.4.1.20044.3.2.3.3.211.1.6Columnpm1008AlmRxNrPortnread-onlycurrentLine Optical Rx Not Ready :This OID indicates that a condition has arisen leading to invalid data on the receiving side. <Help> This alarm indicates if the Rx …
1.3.6.1.4.1.20044.3.2.3.3.211.1.7Columnpm1008AlmTxCdrNotLockedPortnread-onlycurrentLine Optical Tx CDR Unlocked :This OID indicates a loss of lock on the transmitting side CDR has been detected. <Help> This alarm indicates if the Tx CDR is lo…
1.3.6.1.4.1.20044.3.2.3.3.211.1.8Columnpm1008AlmTxFaultPortnread-onlycurrentLine Optical Tx Failure :This OID indicates a fault condition on the laser detected by the safety syste <Help> This alarm indicates if the laser of the line tr…
1.3.6.1.4.1.20044.3.2.3.3.211.1.9Columnpm1008AlmTxNrPortnread-onlycurrentLine Optical Tx Not Ready :This OID indicates a condition has arisen leading to invalid data on the transmitting side <Help> This alarm indicates if the Tx par…
1.3.6.1.4.1.20044.3.2.3.3.211.1.15Columnpm1008AlmWavelengthUnlockedPortnread-onlycurrentLine Optical Tx Wavelength Unlocked :This OID indicates that the wavelength error is exceeding the manufacturer tolerance <Help> This alarm indicates if the wa…
1.3.6.1.4.1.20044.3.2.3.3.211.1.16Columnpm1008AlmTecFaultPortnread-onlycurrentLine Optical Tx Temp Regul Failed :This OID indicates a failure on the TEC module <Help> This alarm indicates if the TEC of the line transceiver is in fail con…
1.3.6.1.4.1.20044.3.2.3.3.211.1.17Columnpm1008AlmApdSupplyFaultPortnread-onlycurrentLine Rx Photodiode Power Failed :This OID indicates a failure on the APD power supply <Help> This alarm indicates if the APD power supply is in fail condition …
1.3.6.1.4.1.20044.3.3Nodepm1008measures
1.3.6.1.4.1.20044.3.3.1Nodepm1008MesrOther
1.3.6.1.4.1.20044.3.3.1.0Scalarpm1008Mesrsynth0read-onlydeprecatedNot Used :This OID gives the unit used on AUX1 measurement of XFP#1 (Unit = )
1.3.6.1.4.1.20044.3.3.1.1Scalarpm1008Mesrsynth1read-onlydeprecatedNot Used :This OID gives the unit used on AUX2 measurement of XFP#1 (Unit = )
1.3.6.1.4.1.20044.3.3.2Nodepm1008MesrClient
1.3.6.1.4.1.20044.3.3.2.16Tablepm1008MesrtempMeasTablenot-accessiblecurrentList of pm1008MesrtempMeas Article
1.3.6.1.4.1.20044.3.3.2.16.1Rowpm1008MesrtempMeasEntrynot-accessiblecurrentRow definition for the pm1008MesrtempMeas table
1.3.6.1.4.1.20044.3.3.2.16.1.1Columnpm1008MesrtempMeasIndexread-onlycurrentIndex definition for the pm1008MesrtempMeas table
1.3.6.1.4.1.20044.3.3.2.16.1.2Columnpm1008MesrtempMeasPortnread-onlycurrentClient SFP Temperature :This OID gives the temperature value of the SFP plugged in port, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/25…
1.3.6.1.4.1.20044.3.3.2.24Tablepm1008MesrvoltMeasTablenot-accessiblecurrentList of pm1008MesrvoltMeas Article
1.3.6.1.4.1.20044.3.3.2.24.1Rowpm1008MesrvoltMeasEntrynot-accessiblecurrentRow definition for the pm1008MesrvoltMeas table
1.3.6.1.4.1.20044.3.3.2.24.1.1Columnpm1008MesrvoltMeasIndexread-onlycurrentIndex definition for the pm1008MesrvoltMeas table
1.3.6.1.4.1.20044.3.3.2.24.1.2Columnpm1008MesrvoltMeasPortnread-onlycurrentClient SFP Power Supply :This OID gives the 3V3 voltage value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/100…
1.3.6.1.4.1.20044.3.3.2.32Tablepm1008MesrbiasMeasTablenot-accessiblecurrentList of pm1008MesrbiasMeas Article
1.3.6.1.4.1.20044.3.3.2.32.1Rowpm1008MesrbiasMeasEntrynot-accessiblecurrentRow definition for the pm1008MesrbiasMeas table
1.3.6.1.4.1.20044.3.3.2.32.1.1Columnpm1008MesrbiasMeasIndexread-onlycurrentIndex definition for the pm1008MesrbiasMeas table
1.3.6.1.4.1.20044.3.3.2.32.1.2Columnpm1008MesrbiasMeasPortnread-onlycurrentClient SFP Laser Bias :This OID gives the bias value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA…
1.3.6.1.4.1.20044.3.3.2.40Tablepm1008MesrtxpwrMeasTablenot-accessiblecurrentList of pm1008MesrtxpwrMeas Article
1.3.6.1.4.1.20044.3.3.2.40.1Rowpm1008MesrtxpwrMeasEntrynot-accessiblecurrentRow definition for the pm1008MesrtxpwrMeas table
1.3.6.1.4.1.20044.3.3.2.40.1.1Columnpm1008MesrtxpwrMeasIndexread-onlycurrentIndex definition for the pm1008MesrtxpwrMeas table
1.3.6.1.4.1.20044.3.3.2.40.1.2Columnpm1008MesrtxpwrMeasPortnread-onlycurrentClient SFP Tx Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV…
1.3.6.1.4.1.20044.3.3.2.48Tablepm1008MesrrxpwrMeasTablenot-accessiblecurrentList of pm1008MesrrxpwrMeas Article
1.3.6.1.4.1.20044.3.3.2.48.1Rowpm1008MesrrxpwrMeasEntrynot-accessiblecurrentRow definition for the pm1008MesrrxpwrMeas table
1.3.6.1.4.1.20044.3.3.2.48.1.1Columnpm1008MesrrxpwrMeasIndexread-onlycurrentIndex definition for the pm1008MesrrxpwrMeas table
1.3.6.1.4.1.20044.3.3.2.48.1.2Columnpm1008MesrrxpwrMeasPortnread-onlycurrentClient SFP Rx Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-4…
1.3.6.1.4.1.20044.3.3.3Nodepm1008MesrLine
1.3.6.1.4.1.20044.3.3.3.208Tablepm1008Mesrxfp1LxModTempMeasTablenot-accessiblecurrentList of pm1008Mesrxfp1LxModTempMeas Article
1.3.6.1.4.1.20044.3.3.3.208.1Rowpm1008Mesrxfp1LxModTempMeasEntrynot-accessiblecurrentRow definition for the pm1008Mesrxfp1LxModTempMeas table
1.3.6.1.4.1.20044.3.3.3.208.1.1Columnpm1008Mesrxfp1LxModTempMeasIndexread-onlycurrentIndex definition for the pm1008Mesrxfp1LxModTempMeas table
1.3.6.1.4.1.20044.3.3.3.208.1.2Columnpm1008Mesrxfp1LxModTempMeasPortnread-onlycurrentLine Optical Module Temperature :This OID gives the temperature of the XFP or OTX plugged in line#n, read from the DDM (Digital Diagnostic Monitoring) (Tempera…
1.3.6.1.4.1.20044.3.3.3.209Tablepm1008Mesrxfp1ReservedTablenot-accessibledeprecatedList of pm1008Mesrxfp1Reserved Article
1.3.6.1.4.1.20044.3.3.3.209.1Rowpm1008Mesrxfp1ReservedEntrynot-accessibledeprecatedRow definition for the pm1008Mesrxfp1Reserved table
1.3.6.1.4.1.20044.3.3.3.209.1.1Columnpm1008Mesrxfp1ReservedIndexread-onlydeprecatedIndex definition for the pm1008Mesrxfp1Reserved table
1.3.6.1.4.1.20044.3.3.3.209.1.2Columnpm1008Mesrxfp1ReservedPortnread-onlydeprecatedNot Used :Reserved
1.3.6.1.4.1.20044.3.3.3.210Tablepm1008Mesrxfp1LoBiasCurrentMeasTablenot-accessiblecurrentList of pm1008Mesrxfp1LoBiasCurrentMeas Article
1.3.6.1.4.1.20044.3.3.3.210.1Rowpm1008Mesrxfp1LoBiasCurrentMeasEntrynot-accessiblecurrentRow definition for the pm1008Mesrxfp1LoBiasCurrentMeas table
1.3.6.1.4.1.20044.3.3.3.210.1.1Columnpm1008Mesrxfp1LoBiasCurrentMeasIndexread-onlycurrentIndex definition for the pm1008Mesrxfp1LoBiasCurrentMeas table
1.3.6.1.4.1.20044.3.3.3.210.1.2Columnpm1008Mesrxfp1LoBiasCurrentMeasPortnread-onlycurrentLine Optical Module Laser Bias :This OID gives the bias value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Bias = A…
1.3.6.1.4.1.20044.3.3.3.211Tablepm1008Mesrxfp1LoTxPowerMeasTablenot-accessiblecurrentList of pm1008Mesrxfp1LoTxPowerMeas Article
1.3.6.1.4.1.20044.3.3.3.211.1Rowpm1008Mesrxfp1LoTxPowerMeasEntrynot-accessiblecurrentRow definition for the pm1008Mesrxfp1LoTxPowerMeas table
1.3.6.1.4.1.20044.3.3.3.211.1.1Columnpm1008Mesrxfp1LoTxPowerMeasIndexread-onlycurrentIndex definition for the pm1008Mesrxfp1LoTxPowerMeas table
1.3.6.1.4.1.20044.3.3.3.211.1.2Columnpm1008Mesrxfp1LoTxPowerMeasPortnread-onlycurrentLine Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (…
1.3.6.1.4.1.20044.3.3.3.212Tablepm1008Mesrxfp1LiRxPowerMeasTablenot-accessiblecurrentList of pm1008Mesrxfp1LiRxPowerMeas Article
1.3.6.1.4.1.20044.3.3.3.212.1Rowpm1008Mesrxfp1LiRxPowerMeasEntrynot-accessiblecurrentRow definition for the pm1008Mesrxfp1LiRxPowerMeas table
1.3.6.1.4.1.20044.3.3.3.212.1.1Columnpm1008Mesrxfp1LiRxPowerMeasIndexread-onlycurrentIndex definition for the pm1008Mesrxfp1LiRxPowerMeas table
1.3.6.1.4.1.20044.3.3.3.212.1.2Columnpm1008Mesrxfp1LiRxPowerMeasPortnread-onlycurrentLine Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (P…
1.3.6.1.4.1.20044.3.3.3.213Tablepm1008Mesrxfp1LxAux1MeasTablenot-accessibledeprecatedList of pm1008Mesrxfp1LxAux1Meas Article
1.3.6.1.4.1.20044.3.3.3.213.1Rowpm1008Mesrxfp1LxAux1MeasEntrynot-accessibledeprecatedRow definition for the pm1008Mesrxfp1LxAux1Meas table
1.3.6.1.4.1.20044.3.3.3.213.1.1Columnpm1008Mesrxfp1LxAux1MeasIndexread-onlydeprecatedIndex definition for the pm1008Mesrxfp1LxAux1Meas table
1.3.6.1.4.1.20044.3.3.3.213.1.2Columnpm1008Mesrxfp1LxAux1MeasPortnread-onlydeprecatedNot Used :This OID gives the receive power value read in the DDM (Digital Diagnostic Monitoring) of the XFP or OTX plugged in line #n (Unit = ?)
1.3.6.1.4.1.20044.3.3.3.214Tablepm1008Mesrxfp1LxAux2MeasTablenot-accessibledeprecatedList of pm1008Mesrxfp1LxAux2Meas Article
1.3.6.1.4.1.20044.3.3.3.214.1Rowpm1008Mesrxfp1LxAux2MeasEntrynot-accessibledeprecatedRow definition for the pm1008Mesrxfp1LxAux2Meas table
1.3.6.1.4.1.20044.3.3.3.214.1.1Columnpm1008Mesrxfp1LxAux2MeasIndexread-onlydeprecatedIndex definition for the pm1008Mesrxfp1LxAux2Meas table
1.3.6.1.4.1.20044.3.3.3.214.1.2Columnpm1008Mesrxfp1LxAux2MeasPortnread-onlydeprecatedNot Used :This OID gives the receive power value read in the DDM (Digital Diagnostic Monitoring) of the XFP or OTX plugged in line #n (Unit = ?)
1.3.6.1.4.1.20044.3.3.3.224Tablepm1008Mesrotx1AgingTablenot-accessiblecurrentList of pm1008Mesrotx1Aging Article
1.3.6.1.4.1.20044.3.3.3.224.1Rowpm1008Mesrotx1AgingEntrynot-accessiblecurrentRow definition for the pm1008Mesrotx1Aging table
1.3.6.1.4.1.20044.3.3.3.224.1.1Columnpm1008Mesrotx1AgingIndexread-onlycurrentIndex definition for the pm1008Mesrotx1Aging table
1.3.6.1.4.1.20044.3.3.3.224.1.2Columnpm1008Mesrotx1AgingPortnread-onlycurrentLine OTX TLH Aging :This OID gives the aging of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Aging = AV) (Unit = %) <Help> This measure…
1.3.6.1.4.1.20044.3.3.3.225Tablepm1008Mesrotx1LaserTemperatureTablenot-accessibledeprecatedList of pm1008Mesrotx1LaserTemperature Article
1.3.6.1.4.1.20044.3.3.3.225.1Rowpm1008Mesrotx1LaserTemperatureEntrynot-accessibledeprecatedRow definition for the pm1008Mesrotx1LaserTemperature table
1.3.6.1.4.1.20044.3.3.3.225.1.1Columnpm1008Mesrotx1LaserTemperatureIndexread-onlydeprecatedIndex definition for the pm1008Mesrotx1LaserTemperature table
1.3.6.1.4.1.20044.3.3.3.225.1.2Columnpm1008Mesrotx1LaserTemperaturePortnread-onlydeprecatedLine OTX TLH Laser Temperature :This OID gives the laser temperature of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/2…
1.3.6.1.4.1.20044.3.3.3.226Tablepm1008Mesrotx1FreqDeviationTablenot-accessiblecurrentList of pm1008Mesrotx1FreqDeviation Article
1.3.6.1.4.1.20044.3.3.3.226.1Rowpm1008Mesrotx1FreqDeviationEntrynot-accessiblecurrentRow definition for the pm1008Mesrotx1FreqDeviation table
1.3.6.1.4.1.20044.3.3.3.226.1.1Columnpm1008Mesrotx1FreqDeviationIndexread-onlycurrentIndex definition for the pm1008Mesrotx1FreqDeviation table
1.3.6.1.4.1.20044.3.3.3.226.1.2Columnpm1008Mesrotx1FreqDeviationPortnread-onlycurrentLine OTX TLH Frequency Deviation :This OID gives the frequency deviation of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Deviation = (A…
1.3.6.1.4.1.20044.3.3.3.227Tablepm1008Mesrotx1LaserWvlengthTablenot-accessiblecurrentList of pm1008Mesrotx1LaserWvlength Article
1.3.6.1.4.1.20044.3.3.3.227.1Rowpm1008Mesrotx1LaserWvlengthEntrynot-accessiblecurrentRow definition for the pm1008Mesrotx1LaserWvlength table
1.3.6.1.4.1.20044.3.3.3.227.1.1Columnpm1008Mesrotx1LaserWvlengthIndexread-onlycurrentIndex definition for the pm1008Mesrotx1LaserWvlength table
1.3.6.1.4.1.20044.3.3.3.227.1.2Columnpm1008Mesrotx1LaserWvlengthPortnread-onlycurrentLine Optical Module Wavelength :This OID gives the laser wavelength of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Wavelength=29979245…
1.3.6.1.4.1.20044.3.4Nodepm1008counters
1.3.6.1.4.1.20044.3.4.1Nodepm1008CntOther
1.3.6.1.4.1.20044.3.4.2Nodepm1008CntClient
1.3.6.1.4.1.20044.3.4.2.16Tablepm1008CntupRaRemCntTablenot-accessiblecurrentList of pm1008CntupRaRemCnt Article
1.3.6.1.4.1.20044.3.4.2.16.1Rowpm1008CntupRaRemCntEntrynot-accessiblecurrentRow definition for the pm1008CntupRaRemCnt table
1.3.6.1.4.1.20044.3.4.2.16.1.1Columnpm1008CntupRaRemCntIndexread-onlycurrentIndex definition for the pm1008CntupRaRemCnt table
1.3.6.1.4.1.20044.3.4.2.16.1.2Columnpm1008CntupRaRemCntValuePortnread-onlycurrentClient Rate Adapt. Words Removal :This counter is incremented each time a rate adaptation 10B word is removed from the Client input stream
1.3.6.1.4.1.20044.3.4.2.16.1.3Columnpm1008CntupRaRemCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the rate adaptation removal counter value is invalid on Port
1.3.6.1.4.1.20044.3.4.2.16.1.4Columnpm1008CntupRaRemCntOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a rate adaptation removal counter overload on Port
1.3.6.1.4.1.20044.3.4.2.24Tablepm1008CntupRaInsCntTablenot-accessiblecurrentList of pm1008CntupRaInsCnt Article
1.3.6.1.4.1.20044.3.4.2.24.1Rowpm1008CntupRaInsCntEntrynot-accessiblecurrentRow definition for the pm1008CntupRaInsCnt table
1.3.6.1.4.1.20044.3.4.2.24.1.1Columnpm1008CntupRaInsCntIndexread-onlycurrentIndex definition for the pm1008CntupRaInsCnt table
1.3.6.1.4.1.20044.3.4.2.24.1.2Columnpm1008CntupRaInsCntValuePortnread-onlycurrentClient Rate Adapt. Words Insertion :This counter is incremented each time a rate adaptation 10B word is inserted in the Client input stream
1.3.6.1.4.1.20044.3.4.2.24.1.3Columnpm1008CntupRaInsCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the rate adaptation insertion counter value is invalid on Port
1.3.6.1.4.1.20044.3.4.2.24.1.4Columnpm1008CntupRaInsCntOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a rate adaptation insertion counter overload on Port
1.3.6.1.4.1.20044.3.4.2.32Tablepm1008CntupRdErrCntTablenot-accessiblecurrentList of pm1008CntupRdErrCnt Article
1.3.6.1.4.1.20044.3.4.2.32.1Rowpm1008CntupRdErrCntEntrynot-accessiblecurrentRow definition for the pm1008CntupRdErrCnt table
1.3.6.1.4.1.20044.3.4.2.32.1.1Columnpm1008CntupRdErrCntIndexread-onlycurrentIndex definition for the pm1008CntupRdErrCnt table
1.3.6.1.4.1.20044.3.4.2.32.1.2Columnpm1008CntupRdErrCntValuePortnread-onlycurrentClient Input Errors :This counter is increased each time a 10b/8b running disparity error is detected on the Client input stream <Help> This counter gives the …
1.3.6.1.4.1.20044.3.4.2.32.1.3Columnpm1008CntupRdErrCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the client error counter value is invalid on Port
1.3.6.1.4.1.20044.3.4.2.32.1.4Columnpm1008CntupRdErrCntOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a client input error counter overload on Port
1.3.6.1.4.1.20044.3.4.2.40Tablepm1008CntupTimCntTablenot-accessiblecurrentList of pm1008CntupTimCnt Article
1.3.6.1.4.1.20044.3.4.2.40.1Rowpm1008CntupTimCntEntrynot-accessiblecurrentRow definition for the pm1008CntupTimCnt table
1.3.6.1.4.1.20044.3.4.2.40.1.1Columnpm1008CntupTimCntIndexread-onlycurrentIndex definition for the pm1008CntupTimCnt table
1.3.6.1.4.1.20044.3.4.2.40.1.2Columnpm1008CntupTimCntValuePortnread-onlycurrentClient Upstream Timer Counter :This is the timing counter dedicated to the upstream access counters. It is incremented every 125 us.
1.3.6.1.4.1.20044.3.4.2.40.1.3Columnpm1008CntupTimCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the upstream timing counter value is invalid on Port
1.3.6.1.4.1.20044.3.4.2.40.1.4Columnpm1008CntupTimCntOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a upstream timing counter overload on Port
1.3.6.1.4.1.20044.3.4.2.48Tablepm1008CntupCvErrCntTablenot-accessiblecurrentList of pm1008CntupCvErrCnt Article
1.3.6.1.4.1.20044.3.4.2.48.1Rowpm1008CntupCvErrCntEntrynot-accessiblecurrentRow definition for the pm1008CntupCvErrCnt table
1.3.6.1.4.1.20044.3.4.2.48.1.1Columnpm1008CntupCvErrCntIndexread-onlycurrentIndex definition for the pm1008CntupCvErrCnt table
1.3.6.1.4.1.20044.3.4.2.48.1.2Columnpm1008CntupCvErrCntValuePortnread-onlycurrentClient Coding Violation Counter :This counter is increased each time a 10b/8b coding violation is detected on the Client input stream
1.3.6.1.4.1.20044.3.4.2.48.1.3Columnpm1008CntupCvErrCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the coding violation counter value is invalid on Port
1.3.6.1.4.1.20044.3.4.2.48.1.4Columnpm1008CntupCvErrCntOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a coding violation counter overload on Port
1.3.6.1.4.1.20044.3.4.2.64Tablepm1008CntdwCbipCntTablenot-accessiblecurrentList of pm1008CntdwCbipCnt Article
1.3.6.1.4.1.20044.3.4.2.64.1Rowpm1008CntdwCbipCntEntrynot-accessiblecurrentRow definition for the pm1008CntdwCbipCnt table
1.3.6.1.4.1.20044.3.4.2.64.1.1Columnpm1008CntdwCbipCntIndexread-onlycurrentIndex definition for the pm1008CntdwCbipCnt table
1.3.6.1.4.1.20044.3.4.2.64.1.2Columnpm1008CntdwCbipCntValuePortnread-onlycurrentClient Output Errors :This counter is incremented each time a CBIP parity error is detected on the Client output stream <Help> This counter gives the number of…
1.3.6.1.4.1.20044.3.4.2.64.1.3Columnpm1008CntdwCbipCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the CBIP error counter value is invalid on Port
1.3.6.1.4.1.20044.3.4.2.64.1.4Columnpm1008CntdwCbipCntOverloadPortnread-onlycurrentClient CBIP Counter Overload :This OID when set indicates a CBIP error counter overload on Port
1.3.6.1.4.1.20044.3.4.2.72Tablepm1008CntdwTimCntTablenot-accessiblecurrentList of pm1008CntdwTimCnt Article
1.3.6.1.4.1.20044.3.4.2.72.1Rowpm1008CntdwTimCntEntrynot-accessiblecurrentRow definition for the pm1008CntdwTimCnt table
1.3.6.1.4.1.20044.3.4.2.72.1.1Columnpm1008CntdwTimCntIndexread-onlycurrentIndex definition for the pm1008CntdwTimCnt table
1.3.6.1.4.1.20044.3.4.2.72.1.2Columnpm1008CntdwTimCntValuePortnread-onlycurrentClient Downstream Timer Counter :This is the timing counter dedicated to the downstream access counters. It is incremented every 125 us.
1.3.6.1.4.1.20044.3.4.2.72.1.3Columnpm1008CntdwTimCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the downstream timer counter value is invalid on Port
1.3.6.1.4.1.20044.3.4.2.72.1.4Columnpm1008CntdwTimCntOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a downstream timer counter overload on Port
1.3.6.1.4.1.20044.3.4.3Nodepm1008CntLine
1.3.6.1.4.1.20044.3.4.3.152Tablepm1008CntdfrmB1ErrCntTablenot-accessiblecurrentList of pm1008CntdfrmB1ErrCnt Article
1.3.6.1.4.1.20044.3.4.3.152.1Rowpm1008CntdfrmB1ErrCntEntrynot-accessiblecurrentRow definition for the pm1008CntdfrmB1ErrCnt table
1.3.6.1.4.1.20044.3.4.3.152.1.1Columnpm1008CntdfrmB1ErrCntIndexread-onlycurrentIndex definition for the pm1008CntdfrmB1ErrCnt table
1.3.6.1.4.1.20044.3.4.3.152.1.2Columnpm1008CntdfrmB1ErrCntValuePortnread-onlycurrentLine Input B1 Errors :This counter is incremented each time a B1 error is detected on the Deframer input stream. <Help> This counter gives the number of B1 err…
1.3.6.1.4.1.20044.3.4.3.152.1.3Columnpm1008CntdfrmB1ErrCntErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the B1 error counter value is invalid on Port
1.3.6.1.4.1.20044.3.4.3.152.1.4Columnpm1008CntdfrmB1ErrCntOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a B1 error counter overload on Port
1.3.6.1.4.1.20044.3.4.3.153Tablepm1008CntdfrmTimCntTablenot-accessiblecurrentList of pm1008CntdfrmTimCnt Article
1.3.6.1.4.1.20044.3.4.3.153.1Rowpm1008CntdfrmTimCntEntrynot-accessiblecurrentRow definition for the pm1008CntdfrmTimCnt table
1.3.6.1.4.1.20044.3.4.3.153.1.1Columnpm1008CntdfrmTimCntIndexread-onlycurrentIndex definition for the pm1008CntdfrmTimCnt table
1.3.6.1.4.1.20044.3.4.3.153.1.2Columnpm1008CntdfrmTimCntValuePortnread-onlycurrentLine Timer Counter :This is the timing counter dedicated to the downstream deframer counters. It is incremented every 125 us.
1.3.6.1.4.1.20044.3.4.3.153.1.3Columnpm1008CntdfrmTimCntErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.3.4.3.153.1.4Columnpm1008CntdfrmTimCntOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.3.4.3.154Tablepm1008CntdfrmPrimLineErrCntTablenot-accessiblecurrentList of pm1008CntdfrmPrimLineErrCnt Article
1.3.6.1.4.1.20044.3.4.3.154.1Rowpm1008CntdfrmPrimLineErrCntEntrynot-accessiblecurrentRow definition for the pm1008CntdfrmPrimLineErrCnt table
1.3.6.1.4.1.20044.3.4.3.154.1.1Columnpm1008CntdfrmPrimLineErrCntIndexread-onlycurrentIndex definition for the pm1008CntdfrmPrimLineErrCnt table
1.3.6.1.4.1.20044.3.4.3.154.1.2Columnpm1008CntdfrmPrimLineErrCntValuePortnread-onlycurrentLine Input FEC Corrected Errors :This counter is incremented each time the FEC is correcting an error on the line input stream. <Help> This counter gives the n…
1.3.6.1.4.1.20044.3.4.3.154.1.3Columnpm1008CntdfrmPrimLineErrCntErrorPortnread-onlycurrentFEC Counter Error :This bit when set indicates the FEC corrected errors counter value is invalid on Line
1.3.6.1.4.1.20044.3.4.3.154.1.4Columnpm1008CntdfrmPrimLineErrCntOverloadPortnread-onlycurrentFEC Counter Overload :This bit when set indicates a FEC corrected errors counter overload on Line
1.3.6.1.4.1.20044.3.4.259Scalarpm1008CntCountersResetread-writecurrentCounters Reset:This OID resets and restarts all the counters
1.3.6.1.4.1.20044.3.4.260Scalarpm1008CntCountersStopread-writecurrentCounters stop:This OID stops all the counters
1.3.6.1.4.1.20044.3.6Nodepm1008controlsWrite
1.3.6.1.4.1.20044.3.6.1Nodepm1008CtrlOther
1.3.6.1.4.1.20044.3.6.1.1Nodepm1008CtrlconfMgnt1
1.3.6.1.4.1.20044.3.6.1.1.1Scalarpm1008CtrlConf1Load1read-writecurrentLoad Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM.
1.3.6.1.4.1.20044.3.6.1.1.2Scalarpm1008CtrlConf2Load1read-writecurrentLoad Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM.
1.3.6.1.4.1.20044.3.6.1.1.10Scalarpm1008CtrlConf2Flash1read-writecurrentWrite Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura…
1.3.6.1.4.1.20044.3.6.1.1.14Scalarpm1008CtrlConf2Clear1read-writecurrentClear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o…
1.3.6.1.4.1.20044.3.6.1.4Nodepm1008Ctrlsynth4
1.3.6.1.4.1.20044.3.6.1.4.1Scalarpm1008CtrlCorrelatOnread-writecurrentEnable Alarm Correlation :This OID enables the alarm correlation in the PM.
1.3.6.1.4.1.20044.3.6.1.4.2Scalarpm1008CtrlCorrelatOffread-writecurrentDisable Alarm Correlation :This OID disables the alarm correlation in the PM.
1.3.6.1.4.1.20044.3.6.1.5Nodepm1008CtrlswMgnt
1.3.6.1.4.1.20044.3.6.1.5.2Scalarpm1008CtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> …
1.3.6.1.4.1.20044.3.6.1.5.3Scalarpm1008CtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th…
1.3.6.1.4.1.20044.3.6.1.5.5Scalarpm1008CtrlLoadSwBank1read-writecurrentSet Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW…
1.3.6.1.4.1.20044.3.6.1.5.6Scalarpm1008CtrlLoadSwBank2read-writecurrentSet Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S…
1.3.6.1.4.1.20044.3.6.1.6Nodepm1008CtrlgwMgnt
1.3.6.1.4.1.20044.3.6.1.6.1Scalarpm1008CtrlCurrentGwResetread-writecurrentActive Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting.
1.3.6.1.4.1.20044.3.6.1.6.5Scalarpm1008CtrlLoadGwBank1read-writecurrentSet Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.3.6.1.6.6Scalarpm1008CtrlLoadGwBank2read-writecurrentSet Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.3.6.1.6.7Scalarpm1008CtrlLoadGwBank3read-writecurrentSet Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.3.6.1.6.8Scalarpm1008CtrlLoadGwBank4read-writecurrentSet Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.3.6.1.192Nodepm1008CtrlledTest
1.3.6.1.4.1.20044.3.6.1.192.1Scalarpm1008CtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.3.6.1.192.2Scalarpm1008CtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.3.6.1.192.3Scalarpm1008CtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.3.6.1.193Nodepm1008CtrlmoduleOosMode
1.3.6.1.4.1.20044.3.6.1.193.1Scalarpm1008CtrlModuleOosModeread-writecurrentPM Out Of Service :This OID sets the PM Out Of Service <Help> This control defines the service state of the complete module
1.3.6.1.4.1.20044.3.6.1.197Nodepm1008CtrlmaintenanceMode
1.3.6.1.4.1.20044.3.6.1.197.1Scalarpm1008CtrlMaintenanceModeread-writecurrentModule Maintenance Mode :This OID enables the maintenance mode on the PM. <Help> This control enables the maintenance mode on the PM.
1.3.6.1.4.1.20044.3.6.1.198Nodepm1008CtrldccEnable
1.3.6.1.4.1.20044.3.6.1.198.1Scalarpm1008CtrlDccEnableread-writecurrentDCC Enable :This OID enables the DCC mode on the PM <Help> This control enables the DCC mode on the PM
1.3.6.1.4.1.20044.3.6.2Nodepm1008CtrlClient
1.3.6.1.4.1.20044.3.6.2.16Tablepm1008CtrlaccessLoopTablenot-accessiblecurrentList of pm1008CtrlaccessLoop Article
1.3.6.1.4.1.20044.3.6.2.16.1Rowpm1008CtrlaccessLoopEntrynot-accessiblecurrentRow definition for the pm1008CtrlaccessLoop table
1.3.6.1.4.1.20044.3.6.2.16.1.1Columnpm1008CtrlaccessLoopIndexread-onlycurrentIndex definition for the pm1008CtrlaccessLoop table
1.3.6.1.4.1.20044.3.6.2.16.1.2Columnpm1008CtrlaccessLoopPortnread-writecurrentClient Facility Loopback :This OID operates a Client Facility Loopback, looping client input signal on the client output port. The loop is located on the clien…
1.3.6.1.4.1.20044.3.6.2.18Tablepm1008CtrlportOosModeTablenot-accessiblecurrentList of pm1008CtrlportOosMode Article
1.3.6.1.4.1.20044.3.6.2.18.1Rowpm1008CtrlportOosModeEntrynot-accessiblecurrentRow definition for the pm1008CtrlportOosMode table
1.3.6.1.4.1.20044.3.6.2.18.1.1Columnpm1008CtrlportOosModeIndexread-onlycurrentIndex definition for the pm1008CtrlportOosMode table
1.3.6.1.4.1.20044.3.6.2.18.1.2Columnpm1008CtrlportOosModePortnread-writecurrentClient Port Out Of Service :This OID sets the client port Out Of Service <Help> This controls defines the service state of the client port
1.3.6.1.4.1.20044.3.6.2.19Tablepm1008CtrlsfpOnCtrlTablenot-accessiblecurrentList of pm1008CtrlsfpOnCtrl Article
1.3.6.1.4.1.20044.3.6.2.19.1Rowpm1008CtrlsfpOnCtrlEntrynot-accessiblecurrentRow definition for the pm1008CtrlsfpOnCtrl table
1.3.6.1.4.1.20044.3.6.2.19.1.1Columnpm1008CtrlsfpOnCtrlIndexread-onlycurrentIndex definition for the pm1008CtrlsfpOnCtrl table
1.3.6.1.4.1.20044.3.6.2.19.1.2Columnpm1008CtrlsfpOnCtrlPortnread-writecurrentClient SFP Optical Laser ON :This OID switches on the SFP.
1.3.6.1.4.1.20044.3.6.2.20Tablepm1008CtrlsfpOffCtrlTablenot-accessiblecurrentList of pm1008CtrlsfpOffCtrl Article
1.3.6.1.4.1.20044.3.6.2.20.1Rowpm1008CtrlsfpOffCtrlEntrynot-accessiblecurrentRow definition for the pm1008CtrlsfpOffCtrl table
1.3.6.1.4.1.20044.3.6.2.20.1.1Columnpm1008CtrlsfpOffCtrlIndexread-onlycurrentIndex definition for the pm1008CtrlsfpOffCtrl table
1.3.6.1.4.1.20044.3.6.2.20.1.2Columnpm1008CtrlsfpOffCtrlPortnread-writecurrentClient SFP Laser Shutdown :This OID switches off the SFP. <Help> This control defines the laser state of the client transceiver
1.3.6.1.4.1.20044.3.6.2.21Tablepm1008CtrlcsfUpInsTablenot-accessiblecurrentList of pm1008CtrlcsfUpIns Article
1.3.6.1.4.1.20044.3.6.2.21.1Rowpm1008CtrlcsfUpInsEntrynot-accessiblecurrentRow definition for the pm1008CtrlcsfUpIns table
1.3.6.1.4.1.20044.3.6.2.21.1.1Columnpm1008CtrlcsfUpInsIndexread-onlycurrentIndex definition for the pm1008CtrlcsfUpIns table
1.3.6.1.4.1.20044.3.6.2.21.1.2Columnpm1008CtrlcsfUpInsPortnread-writecurrentClient Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo…
1.3.6.1.4.1.20044.3.6.2.22Tablepm1008CtrlcaisDwInsTablenot-accessiblecurrentList of pm1008CtrlcaisDwIns Article
1.3.6.1.4.1.20044.3.6.2.22.1Rowpm1008CtrlcaisDwInsEntrynot-accessiblecurrentRow definition for the pm1008CtrlcaisDwIns table
1.3.6.1.4.1.20044.3.6.2.22.1.1Columnpm1008CtrlcaisDwInsIndexread-onlycurrentIndex definition for the pm1008CtrlcaisDwIns table
1.3.6.1.4.1.20044.3.6.2.22.1.2Columnpm1008CtrlcaisDwInsPortnread-writecurrentClient AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port
1.3.6.1.4.1.20044.3.6.2.23Tablepm1008CtrlflowControlTablenot-accessiblecurrentList of pm1008CtrlflowControl Article
1.3.6.1.4.1.20044.3.6.2.23.1Rowpm1008CtrlflowControlEntrynot-accessiblecurrentRow definition for the pm1008CtrlflowControl table
1.3.6.1.4.1.20044.3.6.2.23.1.1Columnpm1008CtrlflowControlIndexread-onlycurrentIndex definition for the pm1008CtrlflowControl table
1.3.6.1.4.1.20044.3.6.2.23.1.2Columnpm1008CtrlflowControlPortnread-writecurrentFlow Control Assertion :This OID, when set, asserts a Pause Frame management on the client Port
1.3.6.1.4.1.20044.3.6.2.26Tablepm1008CtrlclientAccessTermLoopTablenot-accessiblecurrentList of pm1008CtrlclientAccessTermLoop Article
1.3.6.1.4.1.20044.3.6.2.26.1Rowpm1008CtrlclientAccessTermLoopEntrynot-accessiblecurrentRow definition for the pm1008CtrlclientAccessTermLoop table
1.3.6.1.4.1.20044.3.6.2.26.1.1Columnpm1008CtrlclientAccessTermLoopIndexread-onlycurrentIndex definition for the pm1008CtrlclientAccessTermLoop table
1.3.6.1.4.1.20044.3.6.2.26.1.2Columnpm1008CtrlclientAccessTermLoopPortnread-writecurrentClient Terminal Loopback :This OID operates a Client Terminal Loopback, looping client input signal on the client output port. The loop is located on the line …
1.3.6.1.4.1.20044.3.6.2.42Tablepm1008CtrlselectMultirateTablenot-accessiblecurrentList of pm1008CtrlselectMultirate Article
1.3.6.1.4.1.20044.3.6.2.42.1Rowpm1008CtrlselectMultirateEntrynot-accessiblecurrentRow definition for the pm1008CtrlselectMultirate table
1.3.6.1.4.1.20044.3.6.2.42.1.1Columnpm1008CtrlselectMultirateIndexread-onlycurrentIndex definition for the pm1008CtrlselectMultirate table
1.3.6.1.4.1.20044.3.6.2.42.1.2Columnpm1008CtrlselectMultiratePortnread-writecurrentInput Bandwidth Limitation :This control defines the input bandwidth limitation (100 Mb/s, 250 Mb/s, 500 Mb/s or 1Gb/s). <Help> This control defines the input …
1.3.6.1.4.1.20044.3.6.2.48Tablepm1008CtrlprotocolTablenot-accessiblecurrentList of pm1008Ctrlprotocol Article
1.3.6.1.4.1.20044.3.6.2.48.1Rowpm1008CtrlprotocolEntrynot-accessiblecurrentRow definition for the pm1008Ctrlprotocol table
1.3.6.1.4.1.20044.3.6.2.48.1.1Columnpm1008CtrlprotocolIndexread-onlycurrentIndex definition for the pm1008Ctrlprotocol table
1.3.6.1.4.1.20044.3.6.2.48.1.2Columnpm1008CtrlprotocolPortnread-writecurrentClient Protocol: This OID sets the protocol of the Client port.
1.3.6.1.4.1.20044.3.6.3Nodepm1008CtrlLine
1.3.6.1.4.1.20044.3.6.3.64Nodepm1008CtrlcommAccessLoop
1.3.6.1.4.1.20044.3.6.3.64.1Scalarpm1008CtrlCommAccessloopread-writedeprecatedPM Full Access Loop Mode :This OID, when set, puts the module in common access loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.
1.3.6.1.4.1.20044.3.6.3.66Nodepm1008CtrllineLoop
1.3.6.1.4.1.20044.3.6.3.66.1Scalarpm1008CtrlLineLoopread-writedeprecatedPM Line Loop Mode :This OID, when set at '1' puts the module in line loopback mode, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. The Ups…
1.3.6.1.4.1.20044.3.6.3.67Nodepm1008CtrlmsAis
1.3.6.1.4.1.20044.3.6.3.67.1Scalarpm1008CtrlMsAisread-writecurrentInsert MS-AIS/L-AIS On Line Output :This OID, when set, inserts an MS-AIS/L-AIS in the outgoing STM-64/OC-192 signal.
1.3.6.1.4.1.20044.3.6.3.69Tablepm1008CtrlfecDisableTablenot-accessiblecurrentList of pm1008CtrlfecDisable Article
1.3.6.1.4.1.20044.3.6.3.69.1Rowpm1008CtrlfecDisableEntrynot-accessiblecurrentRow definition for the pm1008CtrlfecDisable table
1.3.6.1.4.1.20044.3.6.3.69.1.1Columnpm1008CtrlfecDisableIndexread-onlycurrentIndex definition for the pm1008CtrlfecDisable table
1.3.6.1.4.1.20044.3.6.3.69.1.2Columnpm1008CtrlfecDisablePortnread-writecurrentForward Error Correction Inhibition :This OID, when set, inhibits the Forward Error Correction feature on the line input <Help> This control enables/disables t…
1.3.6.1.4.1.20044.3.6.3.73Nodepm1008CtrlProtMgnt
1.3.6.1.4.1.20044.3.6.3.73.1Scalarpm1008CtrlLineNumberread-writecurrentActive Line Number : This OID sets the active line number
1.3.6.1.4.1.20044.3.6.3.73.2Scalarpm1008CtrlProtModeread-writecurrentLine Switch Mode (Auto Or Manual) :This bit selects the manual (1) or automatic (0) switch method <Help> This control defines the protection switch mode on the…
1.3.6.1.4.1.20044.3.6.3.74Tablepm1008CtrllineOosModeTablenot-accessiblecurrentList of pm1008CtrllineOosMode Article
1.3.6.1.4.1.20044.3.6.3.74.1Rowpm1008CtrllineOosModeEntrynot-accessiblecurrentRow definition for the pm1008CtrllineOosMode table
1.3.6.1.4.1.20044.3.6.3.74.1.1Columnpm1008CtrllineOosModeIndexread-onlycurrentIndex definition for the pm1008CtrllineOosMode table
1.3.6.1.4.1.20044.3.6.3.74.1.2Columnpm1008CtrllineOosModePortnread-writecurrentLine Port Out Of Service :This OID sets the line port Out Of Service <Help> This control defines the service state of the line port
1.3.6.1.4.1.20044.3.6.3.208Tablepm1008CtrlxfpOnoffTablenot-accessiblecurrentList of pm1008CtrlxfpOnoff Article
1.3.6.1.4.1.20044.3.6.3.208.1Rowpm1008CtrlxfpOnoffEntrynot-accessiblecurrentRow definition for the pm1008CtrlxfpOnoff table
1.3.6.1.4.1.20044.3.6.3.208.1.1Columnpm1008CtrlxfpOnoffIndexread-onlycurrentIndex definition for the pm1008CtrlxfpOnoff table
1.3.6.1.4.1.20044.3.6.3.208.1.2Columnpm1008CtrlxfpOnoffPortnread-writecurrentLine Optical Laser Shutdown :This OID switches off the XFP or the OTX <Help> This control defines the laser state of the line transceiver
1.3.6.1.4.1.20044.3.6.3.209Tablepm1008CtrlxfpLineLoopTablenot-accessiblecurrentList of pm1008CtrlxfpLineLoop Article
1.3.6.1.4.1.20044.3.6.3.209.1Rowpm1008CtrlxfpLineLoopEntrynot-accessiblecurrentRow definition for the pm1008CtrlxfpLineLoop table
1.3.6.1.4.1.20044.3.6.3.209.1.1Columnpm1008CtrlxfpLineLoopIndexread-onlycurrentIndex definition for the pm1008CtrlxfpLineLoop table
1.3.6.1.4.1.20044.3.6.3.209.1.2Columnpm1008CtrlxfpLineLoopPortnread-writecurrentLine Facility Loopback :This OID operates a Line Facility Loopback, looping line input signal on the line output port. The loop is located on the line transcei…
1.3.6.1.4.1.20044.3.6.3.210Tablepm1008CtrlxfpXfiLoopTablenot-accessiblecurrentList of pm1008CtrlxfpXfiLoop Article
1.3.6.1.4.1.20044.3.6.3.210.1Rowpm1008CtrlxfpXfiLoopEntrynot-accessiblecurrentRow definition for the pm1008CtrlxfpXfiLoop table
1.3.6.1.4.1.20044.3.6.3.210.1.1Columnpm1008CtrlxfpXfiLoopIndexread-onlycurrentIndex definition for the pm1008CtrlxfpXfiLoop table
1.3.6.1.4.1.20044.3.6.3.210.1.2Columnpm1008CtrlxfpXfiLoopPortnread-writecurrentLine Terminal Loopback :This OID operates a Line Terminal Loopback, looping line input signal on the line output port. The loop is located on all client transc…
1.3.6.1.4.1.20044.3.6.3.212Tablepm1008CtrllineTunableChannelTablenot-accessiblecurrentList of pm1008CtrllineTunableChannel Article
1.3.6.1.4.1.20044.3.6.3.212.1Rowpm1008CtrllineTunableChannelEntrynot-accessiblecurrentRow definition for the pm1008CtrllineTunableChannel table
1.3.6.1.4.1.20044.3.6.3.212.1.1Columnpm1008CtrllineTunableChannelIndexread-onlycurrentIndex definition for the pm1008CtrllineTunableChannel table
1.3.6.1.4.1.20044.3.6.3.212.1.2Columnpm1008CtrllineTunableChannelPortnread-writecurrentITU Channel :This OID selects the ITU channel of the Line OTX TLH Laser <Help> This control defines the ITU channel of the Line OTX TLH Laser
1.3.6.1.4.1.20044.3.6.3.213Tablepm1008CtrllinePhotodiodeModeTablenot-accessiblecurrentList of pm1008CtrllinePhotodiodeMode Article
1.3.6.1.4.1.20044.3.6.3.213.1Rowpm1008CtrllinePhotodiodeModeEntrynot-accessiblecurrentRow definition for the pm1008CtrllinePhotodiodeMode table
1.3.6.1.4.1.20044.3.6.3.213.1.1Columnpm1008CtrllinePhotodiodeModeIndexread-onlycurrentIndex definition for the pm1008CtrllinePhotodiodeMode table
1.3.6.1.4.1.20044.3.6.3.213.1.2Columnpm1008CtrllinePhotodiodeModePortnread-writecurrentOTX TLH Rx Sens. Mode :This OID defines the Rx sensiblity mode of the Line OTX TLH <Help> This control defines the receiver sensibility mode of the Line OTX TL…
1.3.6.1.4.1.20044.3.6.3.214Tablepm1008CtrllinePhotodiodeValueTablenot-accessiblecurrentList of pm1008CtrllinePhotodiodeValue Article
1.3.6.1.4.1.20044.3.6.3.214.1Rowpm1008CtrllinePhotodiodeValueEntrynot-accessiblecurrentRow definition for the pm1008CtrllinePhotodiodeValue table
1.3.6.1.4.1.20044.3.6.3.214.1.1Columnpm1008CtrllinePhotodiodeValueIndexread-onlycurrentIndex definition for the pm1008CtrllinePhotodiodeValue table
1.3.6.1.4.1.20044.3.6.3.214.1.2Columnpm1008CtrllinePhotodiodeValuePortnread-writecurrentOTX TLH Rx Sensibility :This OID sets the Rx sensibility of the Line OTX TLH (custom mode only) <Help> This control defines the receiver sensibility value (onl…
1.3.6.1.4.1.20044.3.6.3.215Tablepm1008CtrllinePowerLaserTablenot-accessiblecurrentList of pm1008CtrllinePowerLaser Article
1.3.6.1.4.1.20044.3.6.3.215.1Rowpm1008CtrllinePowerLaserEntrynot-accessiblecurrentRow definition for the pm1008CtrllinePowerLaser table
1.3.6.1.4.1.20044.3.6.3.215.1.1Columnpm1008CtrllinePowerLaserIndexread-onlycurrentIndex definition for the pm1008CtrllinePowerLaser table
1.3.6.1.4.1.20044.3.6.3.215.1.2Columnpm1008CtrllinePowerLaserPortnread-writecurrentLine Laser Output Power [3-5] :This OID sets the output power value on the laser of the Line OTX TLH (AV=Power*10+158) (Unit = dBm) <Help> This control defines…
1.3.6.1.4.1.20044.3.7Nodepm1008ri
1.3.6.1.4.1.20044.3.7.1Nodepm1008riTable
1.3.6.1.4.1.20044.3.7.1.1Tablepm1008RinvSfpTablenot-accessiblecurrentList of the SFPs on the selected module
1.3.6.1.4.1.20044.3.7.1.1.1Rowpm1008RinvSfpEntrynot-accessiblecurrentRow definition for the SFP table
1.3.6.1.4.1.20044.3.7.1.1.1.1Columnpm1008RinvSfpIndexread-onlycurrentIndex for SFP table
1.3.6.1.4.1.20044.3.7.1.1.1.2Columnpm1008Rinvsfpread-onlycurrentInventory for the SFP: This OID contains the inventory for the SFP
1.3.6.1.4.1.20044.3.7.1.2Tablepm1008RinvLineTablenot-accessiblecurrentList of the XFPs on the selected module
1.3.6.1.4.1.20044.3.7.1.2.1Rowpm1008RinvLineEntrynot-accessiblecurrentRow definition for the XFP table
1.3.6.1.4.1.20044.3.7.1.2.1.1Columnpm1008RinvLineIndexread-onlycurrentIndex for XFP table
1.3.6.1.4.1.20044.3.7.1.2.1.2Columnpm1008RinvxfpLineread-onlycurrentInventory for the XFP: This OID contains the inventory for the XFP
1.3.6.1.4.1.20044.3.7.2Scalarpm1008RinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.3.7.3Scalarpm1008RinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.3.7.4Scalarpm1008RinvModulePlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.3.7.5Scalarpm1008RinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.3.7.6Scalarpm1008RinvGwPlatformread-onlycurrentGW platform desciption: This OID contains the description of the Gateware platform.
1.3.6.1.4.1.20044.3.8Nodepm1008download
1.3.6.1.4.1.20044.3.8.1Nodepm1008DwlOther
1.3.6.1.4.1.20044.3.8.1.0Nodepm1008DwlrestartProcess
1.3.6.1.4.1.20044.3.8.1.0.1Scalarpm1008DwlWarmRestartProcessedread-onlycurrentWarm Restart :This OID indicates that the module last restart was a Warm RESTART
1.3.6.1.4.1.20044.3.8.1.0.2Scalarpm1008DwlColdRestartProcessedread-onlycurrentCold Restart :This OID indicates that the module last restart was a Cold RESTART
1.3.6.1.4.1.20044.3.8.1.1Nodepm1008DwlswBanksUsed
1.3.6.1.4.1.20044.3.8.1.1.1Scalarpm1008DwlSwBank1Usedread-onlycurrentSW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby
1.3.6.1.4.1.20044.3.8.1.1.2Scalarpm1008DwlSwBank2Usedread-onlycurrentSW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby
1.3.6.1.4.1.20044.3.8.1.1.5Scalarpm1008DwlSwBank1Notemptyread-onlycurrentSW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package
1.3.6.1.4.1.20044.3.8.1.1.6Scalarpm1008DwlSwBank2Notemptyread-onlycurrentSW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package
1.3.6.1.4.1.20044.3.8.1.2Nodepm1008DwlgwBanksUsed
1.3.6.1.4.1.20044.3.8.1.2.1Scalarpm1008DwlGwBank1Usedread-onlycurrentGW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby
1.3.6.1.4.1.20044.3.8.1.2.2Scalarpm1008DwlGwBank2Usedread-onlycurrentGW bank 2 active :This OID indicates the module is working on GW bank 2
1.3.6.1.4.1.20044.3.8.1.2.3Scalarpm1008DwlGwBank3Usedread-onlycurrentGW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby
1.3.6.1.4.1.20044.3.8.1.2.4Scalarpm1008DwlGwBank4Usedread-onlycurrentGW bank 4 active :This OID indicates the module is working on GW bank 4
1.3.6.1.4.1.20044.3.8.1.2.5Scalarpm1008DwlGwBank1Notemptyread-onlycurrentGW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package
1.3.6.1.4.1.20044.3.8.1.2.6Scalarpm1008DwlGwBank2Notemptyread-onlycurrentGW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2
1.3.6.1.4.1.20044.3.8.1.2.7Scalarpm1008DwlGwBank3Notemptyread-onlycurrentGW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package
1.3.6.1.4.1.20044.3.8.1.2.8Scalarpm1008DwlGwBank4Notemptyread-onlycurrentGW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4
1.3.6.1.4.1.20044.3.8.2Nodepm1008DwlClient
1.3.6.1.4.1.20044.3.8.3Nodepm1008DwlLine
1.3.6.1.4.1.20044.3.9Nodepm1008Config
1.3.6.1.4.1.20044.3.9.1Nodepm1008CfgAccessCAisCsf
1.3.6.1.4.1.20044.3.9.1.1Tablepm1008CfgClientcaiscsfTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.3.9.1.1.1Rowpm1008CfgClientcaiscsfEntrynot-accessiblecurrentRow definition for the accessCAisCsf table
1.3.6.1.4.1.20044.3.9.1.1.1.1Columnpm1008CfgClientcaiscsfIndexread-onlycurrentIndex definition for the clientcaiscsf table
1.3.6.1.4.1.20044.3.9.1.1.1.3Columnpm1008CfgCAisModePortnread-writecurrentCAIS mode on Client Port :This register enables/disables port laser shutdown on CAIS insertion condition
1.3.6.1.4.1.20044.3.9.1.1.1.9Columnpm1008CfgUpAccessioAlmPortnread-writecurrentCSF contributors on Client Port :This register configures the contributors to upstream CSF insertion on the port.
1.3.6.1.4.1.20044.3.9.1.1.1.10Columnpm1008CfgUpMapperDeAlmPortnread-writecurrentCSF contributors on Client Port :This register configures the contributors to upstream CSF insertion on the port.
1.3.6.1.4.1.20044.3.9.1.1.1.17Columnpm1008CfgDownAccessioAlmPortnread-writecurrentCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port.
1.3.6.1.4.1.20044.3.9.1.1.1.18Columnpm1008CfgDownMapperDeAlmPortnread-writecurrentCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port.
1.3.6.1.4.1.20044.3.9.1.1.1.19Columnpm1008CfgDownDfrmAlmPortnread-writecurrentCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port.
1.3.6.1.4.1.20044.3.9.1.1.1.20Columnpm1008CfgDownLineSyncAlarmsPortnread-writedeprecatedCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port.
1.3.6.1.4.1.20044.3.9.2Nodepm1008CfgStartup
1.3.6.1.4.1.20044.3.9.2.1Tablepm1008CfgClientStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.3.9.2.1.1Rowpm1008CfgClientStartupEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.3.9.2.1.1.1Columnpm1008CfgClientStartupIndexread-onlycurrentIndex definition for the clientStartup table
1.3.6.1.4.1.20044.3.9.2.1.1.3Columnpm1008CfgSystConfPortPortnread-writecurrentDefault Settings on Client Port :This register configures the default initialisation settings on the port.
1.3.6.1.4.1.20044.3.9.2.1.1.4Columnpm1008CfgNetConfPortPortnread-writecurrentDefault Protocol on Client Port :This register configures the default initialisation protocol on the port.
1.3.6.1.4.1.20044.3.9.2.1.1.6Columnpm1008CfgOptionsPortPortnread-writecurrentDefault Options on Client Port :This register configures the default options on the port.
1.3.6.1.4.1.20044.3.9.2.2Nodepm1008tablelineStartup
1.3.6.1.4.1.20044.3.9.2.2.2Scalarpm1008CfgsystConfLine1read-writecurrentDefault Settings on Line 1 :This register configures the default initialisation settings on Line port 1.
1.3.6.1.4.1.20044.3.9.2.2.5Scalarpm1008CfglineOptions1read-writecurrentDefault Options on Active Line Port :This register configures the default options on the active line port
1.3.6.1.4.1.20044.3.9.2.2.6Scalarpm1008CfgsystConfLine2read-writecurrentDefault Settings on Line 2 :This register configures the default initialisation settings on Line port 2.
1.3.6.1.4.1.20044.3.9.2.2.7Scalarpm1008CfglineSelectionread-writecurrentDefault Settings of active line :This register configures the start up active line.
1.3.6.1.4.1.20044.3.9.2.3Tablepm1008CfgXfpTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.3.9.2.3.1Rowpm1008CfgXfpEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.3.9.2.3.1.1Columnpm1008CfgXfpIndexread-onlycurrentIndex definition for the xfp table
1.3.6.1.4.1.20044.3.9.2.3.1.3Columnpm1008CfgSystConfXfpPortnread-writecurrentDefault settings on XFP Port :This register configures the default initialisation settings on XFP port.
1.3.6.1.4.1.20044.3.9.2.3.1.4Columnpm1008CfgDataRateConfXfpPortnread-writedeprecated:Reserved
1.3.6.1.4.1.20044.3.9.3Nodepm1008CfgLabels
1.3.6.1.4.1.20044.3.9.3.1Tablepm1008CfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.3.9.3.1.1Rowpm1008CfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.3.9.3.1.1.1Columnpm1008CfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.3.9.3.1.1.3Columnpm1008CfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.3.9.3.2Tablepm1008CfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.3.9.3.2.1Rowpm1008CfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.3.9.3.2.1.1Columnpm1008CfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.3.9.3.2.1.3Columnpm1008CfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.3.9.4Nodepm1008CfgStartuptlh
1.3.6.1.4.1.20044.3.9.4.1Tablepm1008CfgOtxtlhTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.3.9.4.1.1Rowpm1008CfgOtxtlhEntrynot-accessiblecurrentRow definition for the startuptlh table
1.3.6.1.4.1.20044.3.9.4.1.1.1Columnpm1008CfgOtxtlhIndexread-onlycurrentIndex definition for the otxtlh table
1.3.6.1.4.1.20044.3.9.4.1.1.3Columnpm1008CfgNuPortnread-writedeprecated:
1.3.6.1.4.1.20044.3.9.4.1.1.4Columnpm1008CfgLineDitherRatePortnread-writecurrentDefault Line OTX TLH FM amplitude :This register configures the start-up width of the frequency modulation of the Line OTX TLH
1.3.6.1.4.1.20044.3.9.4.1.1.5Columnpm1008CfgLineDitherFhzPortnread-writecurrentDefault Line OTX TLH FM frequency :This register configures the start-up frequency of the frequency modulation of the Line OTX TLH
1.3.6.1.4.1.20044.3.9.4.1.1.6Columnpm1008CfgLinePwrLaserPortnread-writecurrentDefaut Line OTX TLH output Power :This register configures the start-up output power of the Line OTX TLH (Unit = dBm)
1.3.6.1.4.1.20044.3.9.4.1.1.7Columnpm1008CfgLineFCurrentPortnread-writecurrentDefault Line OTX TLH Channel :This register configures the start-up laser channel of the Line OTX TLH
1.3.6.1.4.1.20044.3.9.4.1.1.8Columnpm1008CfgLineGridCurrentPortnread-writecurrentDefault Line OTX TLH Grid :This register configures the start-up laser grid of the Line OTX TLH
1.3.6.1.4.1.20044.3.9.4.1.1.9Columnpm1008CfgFPortnread-writecurrentDefault Line OTX TLH lowest Freq :This register configures the start-up lowest frequency supported on the Line OTX TLH
1.3.6.1.4.1.20044.3.9.4.1.1.10Columnpm1008CfgReservedPortnread-writedeprecated:
1.3.6.1.4.1.20044.3.9.4.1.1.11Columnpm1008CfgLinePhotodiodeModePortnread-writecurrentDefault Line OTX TLH APD mode :This register configures the start-up APD mode of the Line OTX TLH
1.3.6.1.4.1.20044.3.9.4.1.1.12Columnpm1008CfgLinePhotodiodeValuePortnread-writecurrentDefault Line OTX TLH APD atten. :This register configures the start-up APD attenuation on the Line OTX TLH
1.3.6.1.4.1.20044.3.9.5Nodepm1008CfgStartuptablefive
1.3.6.1.4.1.20044.3.9.5.1Tablepm1008CfgOtxtlhcapabilitiesTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.3.9.5.1.1Rowpm1008CfgOtxtlhcapabilitiesEntrynot-accessiblecurrentRow definition for the startuptablefive table
1.3.6.1.4.1.20044.3.9.5.1.1.1Columnpm1008CfgOtxtlhcapabilitiesIndexread-onlycurrentIndex definition for the otxtlhcapabilities table
1.3.6.1.4.1.20044.3.9.5.1.1.3Columnpm1008CfgComponentTypePortnread-onlycurrentComponent parameters :This OID defines the component parameters
1.3.6.1.4.1.20044.3.9.5.1.1.4Columnpm1008CfgMiscellaneousPortnread-onlycurrentMiscellaneous default settings :This OID defines the miscellaneous parameters
1.3.6.1.4.1.20044.3.9.5.1.1.5Columnpm1008CfgFirstChannelPortnread-onlycurrentNumber of the first channel of the component :This OID defines the first channel number of the PM
1.3.6.1.4.1.20044.3.9.5.1.1.6Columnpm1008CfgLastChannelPortnread-onlycurrentNumber of the last channel of the component :This OID defines the last channel number of the PM
1.3.6.1.4.1.20044.3.9.5.1.1.7Columnpm1008CfgGridPortnread-onlycurrentGrid value of the component :This OID defines the grid of the PM
1.3.6.1.4.1.20044.3.9.257Scalarpm1008CfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.3.10Nodepm1008traps
1.3.6.1.4.1.20044.3.10.2Scalarpm1008trapPortNumberread-onlycurrentLast port which generates a trap
1.3.6.1.4.1.20044.3.10.3Scalarpm1008trapLineNumberread-onlycurrentLast Line which generates a trap
1.3.6.1.4.1.20044.3.10.4Scalarpm1008trapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.3.10.30Notificationpm1008LineTrapNotUrgentGoesOncurrentNot urgent Line default is activated
1.3.6.1.4.1.20044.3.10.31Notificationpm1008LineTrapNotUrgentGoesOffcurrentNot urgent Line default disappeared
1.3.6.1.4.1.20044.3.10.32Notificationpm1008LineTrapUrgentGoesOncurrentUrgent Line default is activated
1.3.6.1.4.1.20044.3.10.33Notificationpm1008LineTrapUrgentGoesOffcurrentUrgent Line default disappeared
1.3.6.1.4.1.20044.3.10.34Notificationpm1008LineTrapCritGoesOncurrentCritical Line default is activated
1.3.6.1.4.1.20044.3.10.35Notificationpm1008LineTrapCritGoesOffcurrentCritical Line default disappeared
1.3.6.1.4.1.20044.3.10.40Notificationpm1008ClientTrapNotUrgentGoesOncurrentNot urgent client default is activated
1.3.6.1.4.1.20044.3.10.41Notificationpm1008ClientTrapNotUrgentGoesOffcurrentNot urgent client default disappeared
1.3.6.1.4.1.20044.3.10.42Notificationpm1008ClientTrapUrgentGoesOncurrentUrgent client default is activated
1.3.6.1.4.1.20044.3.10.43Notificationpm1008ClientTrapUrgentGoesOffcurrentUrgent client default disappeared
1.3.6.1.4.1.20044.3.10.44Notificationpm1008ClientTrapCritGoesOncurrentCritical client default is activated
1.3.6.1.4.1.20044.3.10.45Notificationpm1008ClientTrapCritGoesOffcurrentCritical client default disappeared
1.3.6.1.4.1.20044.3.10.50Notificationpm1008PowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.3.10.51Notificationpm1008PowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared
1.3.6.1.4.1.20044.3.11Nodepm1008Monitoring
1.3.6.1.4.1.20044.3.11.1Nodepm1008MonOther
1.3.6.1.4.1.20044.3.11.1.3Nodepm1008MonRmon
1.3.6.1.4.1.20044.3.11.1.3.359Scalarpm1008MonCountersResetread-writecurrentRMON Counters Reset:This OID resets and restarts all the RMON counters
1.3.6.1.4.1.20044.3.11.1.3.360Scalarpm1008MonCountersStopread-writecurrentRMON Counters stop:This OID stops all the RMON counters
1.3.6.1.4.1.20044.3.11.2Nodepm1008MonClient
1.3.6.1.4.1.20044.3.11.2.4Nodepm1008MonClientRmonCounter
1.3.6.1.4.1.20044.3.11.2.4.16Tablepm1008MonupRmonByteCntTablenot-accessiblecurrentList of pm1008MonupRmonByteCnt Article
1.3.6.1.4.1.20044.3.11.2.4.16.1Rowpm1008MonupRmonByteCntEntrynot-accessiblecurrentRow definition for the pm1008MonupRmonByteCnt table
1.3.6.1.4.1.20044.3.11.2.4.16.1.1Columnpm1008MonupRmonByteCntIndexread-onlycurrentIndex definition for the pm1008MonupRmonByteCnt table
1.3.6.1.4.1.20044.3.11.2.4.16.1.2Columnpm1008MonupRmonByteCntValuePortnread-onlycurrentClient Input Bytes :This counter is increased each time a data byte is received on the client port <Help> This counter gives the number of bytes received on th…
1.3.6.1.4.1.20044.3.11.2.4.16.1.3Columnpm1008MonupRmonByteCntErrorPortnread-onlycurrentBytes Counter Error :This OID when set indicates the Bytes counter value is invalid on clinet port
1.3.6.1.4.1.20044.3.11.2.4.16.1.4Columnpm1008MonupRmonByteCntOverloadPortnread-onlycurrentBytes Counter Overload :This OID when set indicates a Bytes counter overload on client port
1.3.6.1.4.1.20044.3.11.2.4.24Tablepm1008MonupRmonCrcErrorCntTablenot-accessiblecurrentList of pm1008MonupRmonCrcErrorCnt Article
1.3.6.1.4.1.20044.3.11.2.4.24.1Rowpm1008MonupRmonCrcErrorCntEntrynot-accessiblecurrentRow definition for the pm1008MonupRmonCrcErrorCnt table
1.3.6.1.4.1.20044.3.11.2.4.24.1.1Columnpm1008MonupRmonCrcErrorCntIndexread-onlycurrentIndex definition for the pm1008MonupRmonCrcErrorCnt table
1.3.6.1.4.1.20044.3.11.2.4.24.1.2Columnpm1008MonupRmonCrcErrorCntValuePortnread-onlycurrentClient Input CRC Errors :This counter is increased each time a CRC error is detected on the client port <Help> This counter gives the number of CRC Errors rece…
1.3.6.1.4.1.20044.3.11.2.4.24.1.3Columnpm1008MonupRmonCrcErrorCntErrorPortnread-onlycurrentCRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on clinet port
1.3.6.1.4.1.20044.3.11.2.4.24.1.4Columnpm1008MonupRmonCrcErrorCntOverloadPortnread-onlycurrentCRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on client port
1.3.6.1.4.1.20044.3.11.2.4.32Tablepm1008MonupRmonPacketsCntTablenot-accessiblecurrentList of pm1008MonupRmonPacketsCnt Article
1.3.6.1.4.1.20044.3.11.2.4.32.1Rowpm1008MonupRmonPacketsCntEntrynot-accessiblecurrentRow definition for the pm1008MonupRmonPacketsCnt table
1.3.6.1.4.1.20044.3.11.2.4.32.1.1Columnpm1008MonupRmonPacketsCntIndexread-onlycurrentIndex definition for the pm1008MonupRmonPacketsCnt table
1.3.6.1.4.1.20044.3.11.2.4.32.1.2Columnpm1008MonupRmonPacketsCntValuePortnread-onlycurrentClient Input Packets :This counter is increased each time a packet is received on the client port <Help> This counter gives the number of packets received on t…
1.3.6.1.4.1.20044.3.11.2.4.32.1.3Columnpm1008MonupRmonPacketsCntErrorPortnread-onlycurrentPackets Counter Error :This OID when set indicates the Packets counter value is invalid on clinet port
1.3.6.1.4.1.20044.3.11.2.4.32.1.4Columnpm1008MonupRmonPacketsCntOverloadPortnread-onlycurrentPackets Counter Overload :This OID when set indicates a Packets counter overload on client port
1.3.6.1.4.1.20044.3.11.2.4.40Tablepm1008MonupRmonBroadcastCntTablenot-accessiblecurrentList of pm1008MonupRmonBroadcastCnt Article
1.3.6.1.4.1.20044.3.11.2.4.40.1Rowpm1008MonupRmonBroadcastCntEntrynot-accessiblecurrentRow definition for the pm1008MonupRmonBroadcastCnt table
1.3.6.1.4.1.20044.3.11.2.4.40.1.1Columnpm1008MonupRmonBroadcastCntIndexread-onlycurrentIndex definition for the pm1008MonupRmonBroadcastCnt table
1.3.6.1.4.1.20044.3.11.2.4.40.1.2Columnpm1008MonupRmonBroadcastCntValuePortnread-onlycurrentClient Input Broadcast Packets :This counter is increased each time a broadcast packet is received on the client port <Help> This counter gives the number of B…
1.3.6.1.4.1.20044.3.11.2.4.40.1.3Columnpm1008MonupRmonBroadcastCntErrorPortnread-onlycurrentBroadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on clinet port
1.3.6.1.4.1.20044.3.11.2.4.40.1.4Columnpm1008MonupRmonBroadcastCntOverloadPortnread-onlycurrentBroadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port
1.3.6.1.4.1.20044.3.11.2.4.48Tablepm1008MonupRmonMulticastCntTablenot-accessiblecurrentList of pm1008MonupRmonMulticastCnt Article
1.3.6.1.4.1.20044.3.11.2.4.48.1Rowpm1008MonupRmonMulticastCntEntrynot-accessiblecurrentRow definition for the pm1008MonupRmonMulticastCnt table
1.3.6.1.4.1.20044.3.11.2.4.48.1.1Columnpm1008MonupRmonMulticastCntIndexread-onlycurrentIndex definition for the pm1008MonupRmonMulticastCnt table
1.3.6.1.4.1.20044.3.11.2.4.48.1.2Columnpm1008MonupRmonMulticastCntValuePortnread-onlycurrentClient Input Multicast Packets :This counter is increased each time a Multicast packet is received on the client port <Help> This counter gives the number of M…
1.3.6.1.4.1.20044.3.11.2.4.48.1.3Columnpm1008MonupRmonMulticastCntErrorPortnread-onlycurrentMulticast Counter Error :This OID when set indicates the Multicast counter value is invalid on clinet port
1.3.6.1.4.1.20044.3.11.2.4.48.1.4Columnpm1008MonupRmonMulticastCntOverloadPortnread-onlycurrentMulticast Counter Overload :This OID when set indicates a Multicast counter overload on client port
Type Definitions
NameSyntaxStatusDescription
Pm1008AdjustValueINTEGER { otxadjustvalue0(0), otxadjustvalue1(1), otxadjustvalue2(2), otxadjustvalue3(3), otxadjustvalue4(4), otxadjustvalue5(5), otxadjustvalue6(6), otxadjustvalue7(7), otxadjustvalue8(8), otxadjustvalue9(9), otxadjustvalue10(10) }currentDifferent values in Adjust mode on OTX-TLH on client and line ports
Pm1008MultiRateINTEGER { rate100Mhz(0), rate250Mhz(1), rate500Mhz(2), rate1Ghz(3) }currentdifferent rate for a client port
Pm1008OtxChannelINTEGERcurrentChannel selection on OTX-TLH on client and line ports
Pm1008OtxGridINTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50) }currentDifferent grids on OTX-TLH on client and line ports
Pm1008OtxModeINTEGER { otx80mode(1), otx60mode(2), otxadjustmode(4) }currentDifferent modes on OTX-TLH on client and line ports