EKINOPS-Pm1008DCP-MIB
648 objects
MIB for managing Ekinops modules with PM1008DCP software
Imported Objects
| EKINOPS-MIB | EkiApiState EkiMeasureType EkiMode ekinops EkiOnOff EkiProtocol EkiState EkiSynchroMode |
| SNMPv2-SMI | Counter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20044.27 | IdentitymodulePm1008dcp | MIB for managing Ekinops modules with PM1008DCP software | ||
| 1.3.6.1.4.1.20044.27.2 | Nodepm1008dcpalarms | |||
| 1.3.6.1.4.1.20044.27.2.1 | Nodepm1008dcpAlmOther | |||
| 1.3.6.1.4.1.20044.27.2.1.1 | Nodepm1008dcpAlmOtherNurg | |||
| 1.3.6.1.4.1.20044.27.2.1.1.2 | Nodepm1008dcpAlmsynthAlm2 | |||
| 1.3.6.1.4.1.20044.27.2.1.1.2.1 | Scalarpm1008dcpAlmConfTableSave | read-only | current | PM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> other… |
| 1.3.6.1.4.1.20044.27.2.1.1.2.2 | Scalarpm1008dcpAlmInvUpload | read-only | current | Inventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> other (1) <Alarmtype> other (1) <Polarit… |
| 1.3.6.1.4.1.20044.27.2.1.1.2.3 | Scalarpm1008dcpAlmConfTableLoad | read-only | current | PM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> other (1) <Alarmt… |
| 1.3.6.1.4.1.20044.27.2.1.1.2.4 | Scalarpm1008dcpAlmCorrelatOff | read-only | current | Not Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> other (1) <Alarmtype> other (1) <Pol… |
| 1.3.6.1.4.1.20044.27.2.1.1.2.5 | Scalarpm1008dcpAlmMaintenanceOn | read-only | current | Maintenance Mode :This OID indicates that the PM is in maintenance mode. <Help> This alarm indicates that the maintenance mode is enabled on the PM <Condtype> … |
| 1.3.6.1.4.1.20044.27.2.1.2 | Nodepm1008dcpAlmOtherUrg | |||
| 1.3.6.1.4.1.20044.27.2.1.2.194 | Nodepm1008dcpAlmmodInitFailLevel2 | |||
| 1.3.6.1.4.1.20044.27.2.1.2.194.1 | Scalarpm1008dcpAlmLedFail | read-only | current | Led Fail :This OID indicates that Led register has not been correctly initalized <Help> This alarm indicates if the module LEDs are correctly initialized <Cond… |
| 1.3.6.1.4.1.20044.27.2.1.2.194.2 | Scalarpm1008dcpAlmNextColdBootForced | read-only | current | Next Cold Boot Forced :This OID indicates that the next Reset will be forced Cold <Help> This alarm indicates that the next reset of the module will be forced … |
| 1.3.6.1.4.1.20044.27.2.1.2.194.3 | Scalarpm1008dcpAlmBootUndone | read-only | current | Boot Undone :This OID indicates that the boot has not been correctly achieved <Help> This alarm indicates if the module has correctly boot <Condtype> BOOT_UNDO… |
| 1.3.6.1.4.1.20044.27.2.1.2.194.4 | Scalarpm1008dcpAlmResetHwInitFail | read-only | current | Reset HW Init Fail :This OID indicates that the HW intialization has caused unknown intial conditions <Help> This alarm indicates if the HW has been correctly … |
| 1.3.6.1.4.1.20044.27.2.1.2.194.5 | Scalarpm1008dcpAlmSwInitFail | read-only | current | SW Init Fail :This OID indicates that the SW intialization has caused unknown intial conditions <Help> This alarm indicates if the SW module is correctly initi… |
| 1.3.6.1.4.1.20044.27.2.1.2.195 | Nodepm1008dcpAlmmodInitFailLevel3 | |||
| 1.3.6.1.4.1.20044.27.2.1.2.195.1 | Scalarpm1008dcpAlmGwIdentFail | read-only | current | GW Ident Fail :This OID indicates that GW identification has not been read <Help> This alarm indicates if the GW has been correctly identified <Condtype> GW_ID… |
| 1.3.6.1.4.1.20044.27.2.1.2.195.2 | Scalarpm1008dcpAlmObmTypeReadFail | read-only | current | OBM Type Read Fail :This OID indicates that OBM type has not been recognized <Help> This alarm indicates if the OBM board has been correctly identified <Condty… |
| 1.3.6.1.4.1.20044.27.2.1.2.195.3 | Scalarpm1008dcpAlmInitModuleFail | read-only | current | Init Module Fail :This OID indicates that the Module has not been correctly initialized <Help> This alarm indicates if the SW module is correctly initialized <… |
| 1.3.6.1.4.1.20044.27.2.1.2.195.5 | Scalarpm1008dcpAlmXfp1InitFail | read-only | current | XFP1 Init Fail :This OID indicates that the XFP has not been correctly initialized <Help> This alarm indicates if the line transceiver 1 is correctly initializ… |
| 1.3.6.1.4.1.20044.27.2.1.2.195.6 | Scalarpm1008dcpAlmXfp2InitFail | read-only | current | XFP2 Init Fail :This OID indicates that the XFP has not been correctly initialized <Help> This alarm indicates if the line transceiver 2 is correctly initializ… |
| 1.3.6.1.4.1.20044.27.2.1.2.195.7 | Scalarpm1008dcpAlmLine1InitFail | read-only | current | Line1 Init Fail :This OID indicates that the Line registersvsubset has not been correctly initialized <Help> This alarm indicates if the line port 1 is correct… |
| 1.3.6.1.4.1.20044.27.2.1.2.195.8 | Scalarpm1008dcpAlmLine2InitFail | read-only | current | Line2 Init Fail :This OID indicates that the Line register subset has not been correctly initialized <Help> This alarm indicates if the line port 2 is correctl… |
| 1.3.6.1.4.1.20044.27.2.1.2.195.9 | Scalarpm1008dcpAlmClient1InitFail | read-only | current | Client1 Init Fail :This OID indicates that Client 1 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 1 is cor… |
| 1.3.6.1.4.1.20044.27.2.1.2.195.10 | Scalarpm1008dcpAlmClient2InitFail | read-only | current | Client2 Init Fail :This OID indicates that Client 2 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 2 is cor… |
| 1.3.6.1.4.1.20044.27.2.1.2.195.11 | Scalarpm1008dcpAlmClient3InitFail | read-only | current | Client3 Init Fail :This OID indicates that Client 3 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 3 is cor… |
| 1.3.6.1.4.1.20044.27.2.1.2.195.12 | Scalarpm1008dcpAlmClient4InitFail | read-only | current | Client4 Init Fail :This OID indicates that Client 4 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 4 is cor… |
| 1.3.6.1.4.1.20044.27.2.1.2.195.13 | Scalarpm1008dcpAlmClient5InitFail | read-only | current | Client5 Init Fail :This OID indicates that Client 5 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 5 is cor… |
| 1.3.6.1.4.1.20044.27.2.1.2.195.14 | Scalarpm1008dcpAlmClient6InitFail | read-only | current | Client6 Init Fail :This OID indicates that Client 6 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 6 is cor… |
| 1.3.6.1.4.1.20044.27.2.1.2.195.15 | Scalarpm1008dcpAlmClient7InitFail | read-only | current | Client7 Init Fail :This OID indicates that Client 7 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 7 is cor… |
| 1.3.6.1.4.1.20044.27.2.1.2.195.16 | Scalarpm1008dcpAlmClient8InitFail | read-only | current | Client8 Init Fail :This OID indicates that Client 8 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 8 is cor… |
| 1.3.6.1.4.1.20044.27.2.1.2.198 | Nodepm1008dcpAlmadddropTsClientRxProt | |||
| 1.3.6.1.4.1.20044.27.2.1.2.198.1 | Scalarpm1008dcpAlmAdddropClient1West | read-only | current | Client A West Rx Side Active :This OID indicates the Client #1 is active on West receiving side <Condtype> ADDDROP_CLIENT1_WEST <Probcause> other (1) <Alarmtyp… |
| 1.3.6.1.4.1.20044.27.2.1.2.198.2 | Scalarpm1008dcpAlmAdddropClient2West | read-only | current | Client B West Rx Side Active :This OID indicates the Client #2 is active on West receiving side <Condtype> ADDDROP_CLIENT2_WEST <Probcause> other (1) <Alarmtyp… |
| 1.3.6.1.4.1.20044.27.2.1.2.198.3 | Scalarpm1008dcpAlmAdddropClient3West | read-only | current | Client 3 West Rx Side Active :This OID indicates the Client #3 is active on West receiving side <Condtype> ADDDROP_CLIENT3_WEST <Probcause> other (1) <Alarmtyp… |
| 1.3.6.1.4.1.20044.27.2.1.2.198.4 | Scalarpm1008dcpAlmAdddropClient4West | read-only | current | Client 4 West Rx Side Active :This OID indicates the Client #4 is active on West receiving side <Condtype> ADDDROP_CLIENT4_WEST <Probcause> other (1) <Alarmtyp… |
| 1.3.6.1.4.1.20044.27.2.1.2.198.5 | Scalarpm1008dcpAlmAdddropClient5West | read-only | current | Client 5 West Rx Side Active :This OID indicates the Client #5 is active on West receiving side <Condtype> ADDDROP_CLIENT5_WEST <Probcause> other (1) <Alarmtyp… |
| 1.3.6.1.4.1.20044.27.2.1.2.198.6 | Scalarpm1008dcpAlmAdddropClient6West | read-only | current | Client 6 West Rx Side Active :This OID indicates the Client #6 is active on West receiving side <Condtype> ADDDROP_CLIENT6_WEST <Probcause> other (1) <Alarmtyp… |
| 1.3.6.1.4.1.20044.27.2.1.2.198.7 | Scalarpm1008dcpAlmAdddropClient7West | read-only | current | Client 7 West Rx Side Active :This OID indicates the Client #7 is active on West receiving side <Condtype> ADDDROP_CLIENT7_WEST <Probcause> other (1) <Alarmtyp… |
| 1.3.6.1.4.1.20044.27.2.1.2.198.8 | Scalarpm1008dcpAlmAdddropClient8West | read-only | current | Client 8 West Rx Side Active :This OID indicates the Client #8 is active on West receiving side <Condtype> ADDDROP_CLIENT8_WEST <Probcause> other (1) <Alarmtyp… |
| 1.3.6.1.4.1.20044.27.2.1.2.198.9 | Scalarpm1008dcpAlmAdddropClient1East | read-only | current | Client A East Rx Side Active :This OID indicates the Client #1 is active on East receiving side <Condtype> ADDDROP_CLIENT1_EAST <Probcause> other (1) <Alarmtyp… |
| 1.3.6.1.4.1.20044.27.2.1.2.198.10 | Scalarpm1008dcpAlmAdddropClient2East | read-only | current | Client B East Rx Side Active :This OID indicates the Client #2 is active on East receiving side <Condtype> ADDDROP_CLIENT2_EAST <Probcause> other (1) <Alarmtyp… |
| 1.3.6.1.4.1.20044.27.2.1.2.198.11 | Scalarpm1008dcpAlmAdddropClient3East | read-only | current | Client 3 East Rx Side Active :This OID indicates the Client #3 is active on East receiving side <Condtype> ADDDROP_CLIENT3_EAST <Probcause> other (1) <Alarmtyp… |
| 1.3.6.1.4.1.20044.27.2.1.2.198.12 | Scalarpm1008dcpAlmAdddropClient4East | read-only | current | Client 4 East Rx Side Active :This OID indicates the Client #4 is active on East receiving side <Condtype> ADDDROP_CLIENT4_EAST <Probcause> other (1) <Alarmtyp… |
| 1.3.6.1.4.1.20044.27.2.1.2.198.13 | Scalarpm1008dcpAlmAdddropClient5East | read-only | current | Client 5 East Rx Side Active :This OID indicates the Client #5 is active on East receiving side <Condtype> ADDDROP_CLIENT5_EAST <Probcause> other (1) <Alarmtyp… |
| 1.3.6.1.4.1.20044.27.2.1.2.198.14 | Scalarpm1008dcpAlmAdddropClient6East | read-only | current | Client 6 East Rx Side Active :This OID indicates the Client #6 is active on East receiving side <Condtype> ADDDROP_CLIENT6_EAST <Probcause> other (1) <Alarmtyp… |
| 1.3.6.1.4.1.20044.27.2.1.2.198.15 | Scalarpm1008dcpAlmAdddropClient7East | read-only | current | Client 7 East Rx Side Active :This OID indicates the Client #7 is active on East receiving side <Condtype> ADDDROP_CLIENT7_EAST <Probcause> other (1) <Alarmtyp… |
| 1.3.6.1.4.1.20044.27.2.1.2.198.16 | Scalarpm1008dcpAlmAdddropClient8East | read-only | current | Client 8 East Rx Side Active :This OID indicates the Client #8 is active on East receiving side <Condtype> ADDDROP_CLIENT8_EAST <Probcause> other (1) <Alarmtyp… |
| 1.3.6.1.4.1.20044.27.2.1.3 | Nodepm1008dcpAlmOtherCrit | |||
| 1.3.6.1.4.1.20044.27.2.1.3.0 | Nodepm1008dcpAlmsynthAlm0 | |||
| 1.3.6.1.4.1.20044.27.2.1.3.0.9 | Scalarpm1008dcpAlmModGlobFail | read-only | current | Module Failure :This OID is set on detection of a failure originating from the PM <Condtype> MOD_GLOB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> sy… |
| 1.3.6.1.4.1.20044.27.2.1.3.0.15 | Scalarpm1008dcpAlmDefFuseA | read-only | current | Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.27.2.1.3.0.16 | Scalarpm1008dcpAlmDefFuseB | read-only | current | Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.27.2.2 | Nodepm1008dcpAlmClient | |||
| 1.3.6.1.4.1.20044.27.2.2.1 | Nodepm1008dcpAlmClientNurg | |||
| 1.3.6.1.4.1.20044.27.2.2.1.48 | Tablepm1008dcpAlmsfpWarnDdmTable | not-accessible | current | List of pm1008dcpAlmsfpWarnDdm Article |
| 1.3.6.1.4.1.20044.27.2.2.1.48.1 | Rowpm1008dcpAlmsfpWarnDdmEntry | not-accessible | current | Row definition for the pm1008dcpAlmsfpWarnDdm table |
| 1.3.6.1.4.1.20044.27.2.2.1.48.1.1 | Columnpm1008dcpAlmsfpWarnDdmIndex | read-only | current | Index definition for the pm1008dcpAlmsfpWarnDdm table |
| 1.3.6.1.4.1.20044.27.2.2.1.48.1.2 | Columnpm1008dcpAlmTxPwLowWngPortn | read-only | current | Client SFP Tx Power Low Warning :Warning indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> TX… |
| 1.3.6.1.4.1.20044.27.2.2.1.48.1.3 | Columnpm1008dcpAlmTxPwrHighWngPortn | read-only | current | Client SFP Tx Power High Warning :Warning indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> … |
| 1.3.6.1.4.1.20044.27.2.2.1.48.1.4 | Columnpm1008dcpAlmTxBiasLowWngPortn | read-only | current | Client SFP Bias Low Warning :Warning indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> … |
| 1.3.6.1.4.1.20044.27.2.2.1.48.1.5 | Columnpm1008dcpAlmTxBiasHighWngPortn | read-only | current | Client SFP Bias High Warning :Warning indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype… |
| 1.3.6.1.4.1.20044.27.2.2.1.48.1.6 | Columnpm1008dcpAlmVccLowWngPortn | read-only | current | Client SFP Power Supply Low Warning :Warning indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype… |
| 1.3.6.1.4.1.20044.27.2.2.1.48.1.7 | Columnpm1008dcpAlmVccHighWngPortn | read-only | current | Client SFP Power Supply High Warning :Warning indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condty… |
| 1.3.6.1.4.1.20044.27.2.2.1.48.1.8 | Columnpm1008dcpAlmTempLowWngPortn | read-only | current | Client SFP Temp Low Warning :Warning indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> TEMP_LO… |
| 1.3.6.1.4.1.20044.27.2.2.1.48.1.9 | Columnpm1008dcpAlmTempHighWngPortn | read-only | current | Client SFP Temp High Warning :Warning indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> TEMP_… |
| 1.3.6.1.4.1.20044.27.2.2.1.48.1.16 | Columnpm1008dcpAlmRxPwrLowWngPortn | read-only | current | Client SFP Rx Power Low Warning :Warning indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> RX_… |
| 1.3.6.1.4.1.20044.27.2.2.1.48.1.17 | Columnpm1008dcpAlmRxPwrHighWngPortn | read-only | current | Client SFP Rx Power High Warning :Warning indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> R… |
| 1.3.6.1.4.1.20044.27.2.2.2 | Nodepm1008dcpAlmClientUrg | |||
| 1.3.6.1.4.1.20044.27.2.2.2.32 | Tablepm1008dcpAlmsfpAlmDdmTable | not-accessible | current | List of pm1008dcpAlmsfpAlmDdm Article |
| 1.3.6.1.4.1.20044.27.2.2.2.32.1 | Rowpm1008dcpAlmsfpAlmDdmEntry | not-accessible | current | Row definition for the pm1008dcpAlmsfpAlmDdm table |
| 1.3.6.1.4.1.20044.27.2.2.2.32.1.1 | Columnpm1008dcpAlmsfpAlmDdmIndex | read-only | current | Index definition for the pm1008dcpAlmsfpAlmDdm table |
| 1.3.6.1.4.1.20044.27.2.2.2.32.1.2 | Columnpm1008dcpAlmTxPwrLowAlaPortn | read-only | current | Client SFP Tx Power Low :Alarm indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> TX_PWR_LOW_A… |
| 1.3.6.1.4.1.20044.27.2.2.2.32.1.3 | Columnpm1008dcpAlmTxPwrHighAlaPortn | read-only | current | Client SFP Tx Power High :Alarm indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> TX_PWR_HIG… |
| 1.3.6.1.4.1.20044.27.2.2.2.32.1.4 | Columnpm1008dcpAlmTxBiasLowAlaPortn | read-only | current | Client SFP Bias Low :Alarm indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> TX_BIAS_LO… |
| 1.3.6.1.4.1.20044.27.2.2.2.32.1.5 | Columnpm1008dcpAlmTxBiasHighAlaPortn | read-only | current | Client SFP Bias High :Alarm indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype> TX_BIAS_… |
| 1.3.6.1.4.1.20044.27.2.2.2.32.1.6 | Columnpm1008dcpAlmVccLowAlaPortn | read-only | current | Client SFP Power Supply Low :Alarm indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype> VCC_LOW_… |
| 1.3.6.1.4.1.20044.27.2.2.2.32.1.7 | Columnpm1008dcpAlmVccHighAlaPortn | read-only | current | Client SFP Power Supply High :Alarm indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condtype> VCC_HI… |
| 1.3.6.1.4.1.20044.27.2.2.2.32.1.8 | Columnpm1008dcpAlmTempLowAlaPortn | read-only | current | Client SFP Temp Low :Alarm indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> TEMP_LOW_ALA_1 <P… |
| 1.3.6.1.4.1.20044.27.2.2.2.32.1.9 | Columnpm1008dcpAlmTempHighAlaPortn | read-only | current | Client SFP Temp High :Alarm indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> TEMP_HIGH_ALA_1… |
| 1.3.6.1.4.1.20044.27.2.2.2.32.1.16 | Columnpm1008dcpAlmRxPwrLowAlaPortn | read-only | current | Client SFP Rx Power Low :Alarm indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> RX_PWR_LOW_AL… |
| 1.3.6.1.4.1.20044.27.2.2.2.32.1.17 | Columnpm1008dcpAlmRxPwrHighAlaPortn | read-only | current | Client SFP Rx Power High :Alarm indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> RX_PWR_HIGH… |
| 1.3.6.1.4.1.20044.27.2.2.3 | Nodepm1008dcpAlmClientCrit | |||
| 1.3.6.1.4.1.20044.27.2.2.3.8 | Tablepm1008dcpAlmsynthAlmPortTable | not-accessible | current | List of pm1008dcpAlmsynthAlmPort Article |
| 1.3.6.1.4.1.20044.27.2.2.3.8.1 | Rowpm1008dcpAlmsynthAlmPortEntry | not-accessible | current | Row definition for the pm1008dcpAlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.27.2.2.3.8.1.1 | Columnpm1008dcpAlmsynthAlmPortIndex | read-only | current | Index definition for the pm1008dcpAlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.27.2.2.3.8.1.2 | Columnpm1008dcpAlmSfpAbsentPortn | read-only | current | Client SFP Absent :This OID indicates that the SFP module is not present in the client port. <Help> This alarm indicates if the client transceiver is present. … |
| 1.3.6.1.4.1.20044.27.2.2.3.8.1.3 | Columnpm1008dcpAlmDdmAbsentPortn | read-only | current | DDM Supported On Client SFP :This OID indicates that the Client SFP module supports the Digital Diagnostic Monitoring function <Help> This status indicates if … |
| 1.3.6.1.4.1.20044.27.2.2.3.8.1.5 | Columnpm1008dcpAlmHwFailAccPortn | read-only | current | Client HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Condtype> HW_FAIL_ACC_1 <Probcause> equipmentMalfunction (16)… |
| 1.3.6.1.4.1.20044.27.2.2.3.8.1.6 | Columnpm1008dcpAlmDwLsdPortn | read-only | current | Client SFP Laser Shutdown :This OID indicates the Client SFP transmitter output is ON. <Help> This status indicates if the client transceiver laser is ON or OF… |
| 1.3.6.1.4.1.20044.27.2.2.3.8.1.7 | Columnpm1008dcpAlmClientLocalOosPortn | read-only | current | Local Client Port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local c… |
| 1.3.6.1.4.1.20044.27.2.2.3.8.1.8 | Columnpm1008dcpAlmClientRemoteOosPortn | read-only | current | Remote Client Port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the remot… |
| 1.3.6.1.4.1.20044.27.2.2.3.8.1.9 | Columnpm1008dcpAlmDwCaisPortn | read-only | current | Client AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indictaes if a Client Alarm Indication Signal is… |
| 1.3.6.1.4.1.20044.27.2.2.3.8.1.10 | Columnpm1008dcpAlmSfpDdmWarningPortn | read-only | current | Warning On Client SFP DDM :This OID indicates a warning is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Warning has been detecte… |
| 1.3.6.1.4.1.20044.27.2.2.3.8.1.11 | Columnpm1008dcpAlmSfpDdmAlmPortn | read-only | current | Alarm On Client SFP DDM :This OID indicates an alarm is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Alarm has been detected on … |
| 1.3.6.1.4.1.20044.27.2.2.3.8.1.13 | Columnpm1008dcpAlmFailAccPortn | read-only | current | Client Access Fail :This OID indicates a failure on the Client port <Condtype> FAIL_ACC_1 <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12)… |
| 1.3.6.1.4.1.20044.27.2.2.3.8.1.16 | Columnpm1008dcpAlmClientActivePortn | read-only | current | Client Sink (Line1 Or Line2) :This bit indicates the Client #n is active on receive side <Help> This status indicates whether the Client is extracted from Line… |
| 1.3.6.1.4.1.20044.27.2.2.3.8.1.17 | Columnpm1008dcpAlmUpCsfPortn | read-only | current | Client Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu… |
| 1.3.6.1.4.1.20044.27.2.2.3.16 | Tablepm1008dcpAlmaccessioAlmTable | not-accessible | current | List of pm1008dcpAlmaccessioAlm Article |
| 1.3.6.1.4.1.20044.27.2.2.3.16.1 | Rowpm1008dcpAlmaccessioAlmEntry | not-accessible | current | Row definition for the pm1008dcpAlmaccessioAlm table |
| 1.3.6.1.4.1.20044.27.2.2.3.16.1.1 | Columnpm1008dcpAlmaccessioAlmIndex | read-only | current | Index definition for the pm1008dcpAlmaccessioAlm table |
| 1.3.6.1.4.1.20044.27.2.2.3.16.1.2 | Columnpm1008dcpAlmDwLasFailPortn | read-only | current | Client SFP Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the client port (this alarm reports the transmitter failure alarm … |
| 1.3.6.1.4.1.20044.27.2.2.3.16.1.5 | Columnpm1008dcpAlmUpLosPortn | read-only | current | Client Input Loss Of Signal :This OID indicates that no signal is present on the SFP of the client port <Help> This alarm indicates if an optical signal is det… |
| 1.3.6.1.4.1.20044.27.2.2.3.72 | Tablepm1008dcpAlmmapperDeAlmTable | not-accessible | current | List of pm1008dcpAlmmapperDeAlm Article |
| 1.3.6.1.4.1.20044.27.2.2.3.72.1 | Rowpm1008dcpAlmmapperDeAlmEntry | not-accessible | current | Row definition for the pm1008dcpAlmmapperDeAlm table |
| 1.3.6.1.4.1.20044.27.2.2.3.72.1.1 | Columnpm1008dcpAlmmapperDeAlmIndex | read-only | current | Index definition for the pm1008dcpAlmmapperDeAlm table |
| 1.3.6.1.4.1.20044.27.2.2.3.72.1.2 | Columnpm1008dcpAlmUpAccOosPortn | read-only | current | Client Loss Of 10b/8b Synchro :This OID indicates the upstream client input port has lost synchronization on its 10B/8B decoder <Help> This alarms indicates if… |
| 1.3.6.1.4.1.20044.27.2.2.3.72.1.11 | Columnpm1008dcpAlmUpBufferOvlPortn | read-only | current | Client Upstream Buffer Overload :This OID indicates that the rate adaptation buffer for client port is in overload. <Help> This alarm indicates if there is a u… |
| 1.3.6.1.4.1.20044.27.2.2.3.72.1.12 | Columnpm1008dcpAlmDwCsfDetPortn | read-only | current | Client Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client… |
| 1.3.6.1.4.1.20044.27.2.2.3.72.1.15 | Columnpm1008dcpAlmDwBufferOvlPortn | read-only | current | Client Downstream Buffer Overload :This OID indicates that the de-mapper buffer for client port is in overload. <Help> This alarm indicates if there is a downs… |
| 1.3.6.1.4.1.20044.27.2.3 | Nodepm1008dcpAlmLine | |||
| 1.3.6.1.4.1.20044.27.2.3.1 | Nodepm1008dcpAlmLineNurg | |||
| 1.3.6.1.4.1.20044.27.2.3.1.209 | Tablepm1008dcpAlmlineXfp1WarningsTable | not-accessible | current | List of pm1008dcpAlmlineXfp1Warnings Article |
| 1.3.6.1.4.1.20044.27.2.3.1.209.1 | Rowpm1008dcpAlmlineXfp1WarningsEntry | not-accessible | current | Row definition for the pm1008dcpAlmlineXfp1Warnings table |
| 1.3.6.1.4.1.20044.27.2.3.1.209.1.1 | Columnpm1008dcpAlmlineXfp1WarningsIndex | read-only | current | Index definition for the pm1008dcpAlmlineXfp1Warnings table |
| 1.3.6.1.4.1.20044.27.2.3.1.209.1.2 | Columnpm1008dcpAlmTxPowerLowWarningPortn | read-only | current | Line Optical Tx Power Low Warning :Warning indicating that the XFP/OTX transmitter transmitter output power is lower than the threshold value written in the XF… |
| 1.3.6.1.4.1.20044.27.2.3.1.209.1.3 | Columnpm1008dcpAlmTxPowerHighWarningPortn | read-only | current | Line Optical Tx Power High Warning :Warning indicating that the XFP/OTX transmitter transmitter output power is higher than the threshold value written in the … |
| 1.3.6.1.4.1.20044.27.2.3.1.209.1.4 | Columnpm1008dcpAlmTxBiasLowWarningPortn | read-only | current | Line Transceiver Bias Low Warning :Warning indicating that the XFP/OTX transmitter laser bias current is lower than the threshold value written in the XFP/OTX … |
| 1.3.6.1.4.1.20044.27.2.3.1.209.1.5 | Columnpm1008dcpAlmTxBiasHighWarningPortn | read-only | current | Line Transceiver Bias High Warning :Warning indicating that the XFP/OTX transmitter laser bias current is higher than the threshold value written in the XFP EE… |
| 1.3.6.1.4.1.20044.27.2.3.1.209.1.8 | Columnpm1008dcpAlmTempLowWarningPortn | read-only | current | Line Transceiver Temp Low Warning :Warning indicating that the XFP/OTX temperature is lower than the threshold value written in the XFP/OTX EEPROM <Condtype> T… |
| 1.3.6.1.4.1.20044.27.2.3.1.209.1.9 | Columnpm1008dcpAlmTempHighWarningPortn | read-only | current | Line Transceiver Temp High Warning :Warning indicating that the XFP/OTX temperature is higher than the threshold value written in the XFP EEPROM <Condtype> TEM… |
| 1.3.6.1.4.1.20044.27.2.3.1.209.1.16 | Columnpm1008dcpAlmRxPowerLowWarningPortn | read-only | current | Line Optical Rx Power Low Warning :Warning indicating that the XFP received optical power is lower than the threshold value written in the XFP EEPROM <Condtype… |
| 1.3.6.1.4.1.20044.27.2.3.1.209.1.17 | Columnpm1008dcpAlmRxPowerHighWarningPortn | read-only | current | Line Optical Rx Power High Warning :Warning indicating that the XFP received optical power is higher than the threshold value written in the XFP EEPROM <Condty… |
| 1.3.6.1.4.1.20044.27.2.3.1.225 | Tablepm1008dcpAlmlineOtx1TlhWarningsTable | not-accessible | current | List of pm1008dcpAlmlineOtx1TlhWarnings Article |
| 1.3.6.1.4.1.20044.27.2.3.1.225.1 | Rowpm1008dcpAlmlineOtx1TlhWarningsEntry | not-accessible | current | Row definition for the pm1008dcpAlmlineOtx1TlhWarnings table |
| 1.3.6.1.4.1.20044.27.2.3.1.225.1.1 | Columnpm1008dcpAlmlineOtx1TlhWarningsIndex | read-only | current | Index definition for the pm1008dcpAlmlineOtx1TlhWarnings table |
| 1.3.6.1.4.1.20044.27.2.3.1.225.1.6 | Columnpm1008dcpAlmLineModulatorAgingHighWarningPortn | read-only | current | Line Modulator Aging High Warning :Warning indicating the Line OTX TLH modulator aging is higher than the threshold written in the EEPROM <Condtype> LINE_MODUL… |
| 1.3.6.1.4.1.20044.27.2.3.1.225.1.7 | Columnpm1008dcpAlmLineAgingHighWarningPortn | read-only | current | Line OTX TLH Aging High Warning :Warning indicating the Line OTX TLH aging is higher than the threshold written in the EEPROM <Condtype> LINE_AGING_HIGH_WARNIN… |
| 1.3.6.1.4.1.20044.27.2.3.1.225.1.13 | Columnpm1008dcpAlmLineFreqDevHighWarningPortn | read-only | current | Line Freq. Deviation High Warning :Warning indicating the Line OTX TLH frequency deviation is higher than the threshold written in the EEPROM <Condtype> LINE_F… |
| 1.3.6.1.4.1.20044.27.2.3.1.225.1.15 | Columnpm1008dcpAlmLineLaserTempHighWarningPortn | read-only | current | Line Laser Temp. High Warning :Warning indicating the Line OTX TLH laser temperature is higher than the threshold written in the EEPROM <Condtype> LINE_LASER_T… |
| 1.3.6.1.4.1.20044.27.2.3.2 | Nodepm1008dcpAlmLineUrg | |||
| 1.3.6.1.4.1.20044.27.2.3.2.129 | Tablepm1008dcpAlmdfrmBerTable | not-accessible | current | List of pm1008dcpAlmdfrmBer Article |
| 1.3.6.1.4.1.20044.27.2.3.2.129.1 | Rowpm1008dcpAlmdfrmBerEntry | not-accessible | current | Row definition for the pm1008dcpAlmdfrmBer table |
| 1.3.6.1.4.1.20044.27.2.3.2.129.1.1 | Columnpm1008dcpAlmdfrmBerIndex | read-only | current | Index definition for the pm1008dcpAlmdfrmBer table |
| 1.3.6.1.4.1.20044.27.2.3.2.129.1.2 | Columnpm1008dcpAlmLineSignalDegradePortn | read-only | current | Custom Line Signal Degrade :This OID indicates that the line input signal is DEGRADE. The assertion hysteresis can customized by the host <Condtype> LINE_SIGNA… |
| 1.3.6.1.4.1.20044.27.2.3.2.129.1.3 | Columnpm1008dcpAlmLineSignalFailPortn | read-only | current | Custom Line Signal Fail :This OID indicates that the line input signal is FAIL. The assertion hysteresis can be customized by the host <Condtype> LINE_SIGNAL_F… |
| 1.3.6.1.4.1.20044.27.2.3.2.129.1.6 | Columnpm1008dcpAlmLineDegradePortn | read-only | current | Fixed Line Signal Degrade :This OID indicates that the line input signal is DEGRADE. The assetion hysteresis is fixed to 10-8 (assertion) and 10-9 (de-assertio… |
| 1.3.6.1.4.1.20044.27.2.3.2.208 | Tablepm1008dcpAlmlineXfp1AlarmTable | not-accessible | current | List of pm1008dcpAlmlineXfp1Alarm Article |
| 1.3.6.1.4.1.20044.27.2.3.2.208.1 | Rowpm1008dcpAlmlineXfp1AlarmEntry | not-accessible | current | Row definition for the pm1008dcpAlmlineXfp1Alarm table |
| 1.3.6.1.4.1.20044.27.2.3.2.208.1.1 | Columnpm1008dcpAlmlineXfp1AlarmIndex | read-only | current | Index definition for the pm1008dcpAlmlineXfp1Alarm table |
| 1.3.6.1.4.1.20044.27.2.3.2.208.1.2 | Columnpm1008dcpAlmTxPowerLowAlarmPortn | read-only | current | Line Optical Tx Power Low :Alarm indicating that the XFP/OTX transmitter transmitter output power is lower than the threshold value written in the XFP/OTX EEPR… |
| 1.3.6.1.4.1.20044.27.2.3.2.208.1.3 | Columnpm1008dcpAlmTxPowerHighAlarmPortn | read-only | current | Line Optical Tx Power High :Alarm indicating that the XFP/OTX transmitter transmitter output power is higher than the threshold value written in the XFP EEPROM… |
| 1.3.6.1.4.1.20044.27.2.3.2.208.1.4 | Columnpm1008dcpAlmTxBiasLowAlarmPortn | read-only | current | Line Transceiver Bias Low :Alarm indicating that the XFP/OTX transmitter laser bias current is lower than the threshold value written in the XFP/OTX EEPROM <Co… |
| 1.3.6.1.4.1.20044.27.2.3.2.208.1.5 | Columnpm1008dcpAlmTxBiasHighAlarmPortn | read-only | current | Line Transceiver Bias High :Alarm indicating that the XFP/OTX transmitter laser bias current is higher than the threshold value written in the XFP EEPROM <Cond… |
| 1.3.6.1.4.1.20044.27.2.3.2.208.1.8 | Columnpm1008dcpAlmTempLowAlarmPortn | read-only | current | Line Transceiver Temp Low :Alarm indicating that the XFP/OTX temperature is lower than the threshold value written in the XFP/OTX EEPROM <Condtype> TEMP_LOW_AL… |
| 1.3.6.1.4.1.20044.27.2.3.2.208.1.9 | Columnpm1008dcpAlmTempHighAlarmPortn | read-only | current | Line Transceiver Temp High :Alarm indicating that the XFP/OTX temperature is higher than the threshold value written in the XFP EEPROM <Condtype> TEMP_HIGH_ALA… |
| 1.3.6.1.4.1.20044.27.2.3.2.208.1.16 | Columnpm1008dcpAlmRxPowerLowAlarmPortn | read-only | current | Line Optical Rx Power Low :Alarm indicating that the XFP received optical power is lower than the threshold value written in the XFP EEPROM <Condtype> RX_POWER… |
| 1.3.6.1.4.1.20044.27.2.3.2.208.1.17 | Columnpm1008dcpAlmRxPowerHighAlarmPortn | read-only | current | Line Optical Rx Power High :Alarm indicating that the XFP received optical power is higher than the threshold value written in the XFP EEPROM <Condtype> RX_POW… |
| 1.3.6.1.4.1.20044.27.2.3.2.212 | Tablepm1008dcpAlmlineXfp1SupplyAlarmTable | not-accessible | current | List of pm1008dcpAlmlineXfp1SupplyAlarm Article |
| 1.3.6.1.4.1.20044.27.2.3.2.212.1 | Rowpm1008dcpAlmlineXfp1SupplyAlarmEntry | not-accessible | current | Row definition for the pm1008dcpAlmlineXfp1SupplyAlarm table |
| 1.3.6.1.4.1.20044.27.2.3.2.212.1.1 | Columnpm1008dcpAlmlineXfp1SupplyAlarmIndex | read-only | current | Index definition for the pm1008dcpAlmlineXfp1SupplyAlarm table |
| 1.3.6.1.4.1.20044.27.2.3.2.212.1.2 | Columnpm1008dcpAlmVee5LowAlarmPortn | read-only | current | VEE5 Power Supply Low :Alarm indicating the XFP/OTX VEE5 power supply is lower than the threshold written in the EEPROM <Condtype> VEE5_LOW_ALARM_1 <Probcause>… |
| 1.3.6.1.4.1.20044.27.2.3.2.212.1.3 | Columnpm1008dcpAlmVee5HighAlarmPortn | read-only | current | VEE5 Power Supply High :Alarm indicating the XFP/OTX VEE5 power supply is higher than the threshold written in the EEPROM <Condtype> VEE5_HIGH_ALARM_1 <Probcau… |
| 1.3.6.1.4.1.20044.27.2.3.2.212.1.4 | Columnpm1008dcpAlmVcc2LowAlarmPortn | read-only | current | VCC2 Power Supply Low :Alarm indicating the XFP/OTX VCC2 power supply is lower than the threshold written in the EEPROM <Condtype> VCC2_LOW_ALARM_1 <Probcause>… |
| 1.3.6.1.4.1.20044.27.2.3.2.212.1.5 | Columnpm1008dcpAlmVcc2HighAlarmPortn | read-only | current | VCC2 Power Supply High :Alarm indicating the XFP/OTX VCC2 power supply is higher than the threshold written in the EEPROM <Condtype> VCC2_HIGH_ALARM_1 <Probcau… |
| 1.3.6.1.4.1.20044.27.2.3.2.212.1.6 | Columnpm1008dcpAlmVcc3LowAlarmPortn | read-only | current | VCC3 Power Supply Low :Alarm indicating the XFP/OTX VCC3 power supply is lower than the threshold written in the EEPROM <Condtype> VCC3_LOW_ALARM_1 <Probcause>… |
| 1.3.6.1.4.1.20044.27.2.3.2.212.1.7 | Columnpm1008dcpAlmVcc3HighAlarmPortn | read-only | current | VCC3 Power Supply High :Alarm indicating the XFP/OTX VCC3 power supply is higher than the threshold written in the EEPROM <Condtype> VCC3_HIGH_ALARM_1 <Probcau… |
| 1.3.6.1.4.1.20044.27.2.3.2.212.1.8 | Columnpm1008dcpAlmVcc5LowAlarmPortn | read-only | current | VCC5 Power Supply Low :Alarm indicating the XFP/OTX VCC5 power supply is lower than the threshold written in the EEPROM <Condtype> VCC5_LOW_ALARM_1 <Probcause>… |
| 1.3.6.1.4.1.20044.27.2.3.2.212.1.9 | Columnpm1008dcpAlmVcc5HighAlarmPortn | read-only | current | VCC5 Power Supply High :Alarm indicating the XFP/OTX VCC5 power supply is higher than the threshold written in the EEPROM <Condtype> VCC5_HIGH_ALARM_1 <Probcau… |
| 1.3.6.1.4.1.20044.27.2.3.2.212.1.10 | Columnpm1008dcpAlmVee5LowWarningPortn | read-only | current | VEE5 Power Supply Low Warning :Warning indicating the XFP/OTX VEE5 power supply is lower than the threshold written in the EEPROM <Condtype> VEE5_LOW_WARNING_1… |
| 1.3.6.1.4.1.20044.27.2.3.2.212.1.11 | Columnpm1008dcpAlmVee5HighWarningPortn | read-only | current | VEE5 Power Supply High Warning :Warning indicating the XFP/OTX VEE5 power supply is higher than the threshold written in the EEPROM <Condtype> VEE5_HIGH_WARNIN… |
| 1.3.6.1.4.1.20044.27.2.3.2.212.1.12 | Columnpm1008dcpAlmVcc2LowWarningPortn | read-only | current | VCC2 Power Supply Low Warning :Warning indicating the XFP/OTX VCC2 power supply is lower than the threshold written in the EEPROM <Condtype> VCC2_LOW_WARNING_1… |
| 1.3.6.1.4.1.20044.27.2.3.2.212.1.13 | Columnpm1008dcpAlmVcc2HighWarningPortn | read-only | current | VCC2 Power Supply High Warning :Warning indicating the XFP/OTX VCC2 power supply is higher than the threshold written in the EEPROM <Condtype> VCC2_HIGH_WARNIN… |
| 1.3.6.1.4.1.20044.27.2.3.2.212.1.14 | Columnpm1008dcpAlmVcc3LowWarningPortn | read-only | current | VCC3 Power Supply Low Warning :Warning indicating the XFP/OTX VCC3 power supply is lower than the threshold written in the EEPROM <Condtype> VCC3_LOW_WARNING_1… |
| 1.3.6.1.4.1.20044.27.2.3.2.212.1.15 | Columnpm1008dcpAlmVcc3HighWarningPortn | read-only | current | VCC3 Power Supply High Warning :Warning indicating the XFP/OTX VCC3 power supply is higher than the threshold written in the EEPROM <Condtype> VCC3_HIGH_WARNIN… |
| 1.3.6.1.4.1.20044.27.2.3.2.212.1.16 | Columnpm1008dcpAlmVcc5LowWarningPortn | read-only | current | VCC5 Power Supply Low Warning :Warning indicating the XFP/OTX VCC5 power supply is lower than the threshold written in the EEPROM <Condtype> VCC5_LOW_WARNING_1… |
| 1.3.6.1.4.1.20044.27.2.3.2.212.1.17 | Columnpm1008dcpAlmVcc5HighWarningPortn | read-only | current | VCC5 Power Supply High Warning :Warning indicating the XFP/OTX VCC5 power supply is higher than the threshold written in the EEPROM <Condtype> VCC5_HIGH_WARNIN… |
| 1.3.6.1.4.1.20044.27.2.3.2.224 | Tablepm1008dcpAlmlineOtx1TlhAlarmsTable | not-accessible | current | List of pm1008dcpAlmlineOtx1TlhAlarms Article |
| 1.3.6.1.4.1.20044.27.2.3.2.224.1 | Rowpm1008dcpAlmlineOtx1TlhAlarmsEntry | not-accessible | current | Row definition for the pm1008dcpAlmlineOtx1TlhAlarms table |
| 1.3.6.1.4.1.20044.27.2.3.2.224.1.1 | Columnpm1008dcpAlmlineOtx1TlhAlarmsIndex | read-only | current | Index definition for the pm1008dcpAlmlineOtx1TlhAlarms table |
| 1.3.6.1.4.1.20044.27.2.3.2.224.1.6 | Columnpm1008dcpAlmLineModulatorAgingHighAlaPortn | read-only | current | Line Modulator Aging High Alarm :Alarm indicating the Line OTX TLH modulator aging is higher than the threshold written in the EEPROM <Condtype> LINE_MODULATOR… |
| 1.3.6.1.4.1.20044.27.2.3.2.224.1.7 | Columnpm1008dcpAlmLineAgingHighAlaPortn | read-only | current | Line OTX TLH Aging High Alarm :Alarm indicating the Line OTX TLH aging is higher than the threshold written in the EEPROM <Condtype> LINE_AGING_HIGH_ALA_1 <Pro… |
| 1.3.6.1.4.1.20044.27.2.3.2.224.1.10 | Columnpm1008dcpAlmLineCdrNotReadyPortn | read-only | current | CDR Not Ready :This OID indicates the Clock Data Recovery unit is not yet initialized. <Help> This alarm indicates the Clock Data Recovery unit is not yet init… |
| 1.3.6.1.4.1.20044.27.2.3.2.224.1.13 | Columnpm1008dcpAlmLineFreqDevHighAlaPortn | read-only | current | Line Freq. Deviation High Alarm :Alarm indicating the Line OTX TLH frequency deviation is higher than the threshold written in the EEPROM <Condtype> LINE_FREQ_… |
| 1.3.6.1.4.1.20044.27.2.3.2.224.1.15 | Columnpm1008dcpAlmLineLaserTempHighAlaPortn | read-only | current | Line Laser Temp. High Alarm :Alarm indicating the Line OTX TLH laser temperature is higher than the threshold written in the EEPROM <Condtype> LINE_LASER_TEMP_… |
| 1.3.6.1.4.1.20044.27.2.3.3 | Nodepm1008dcpAlmLineCrit | |||
| 1.3.6.1.4.1.20044.27.2.3.3.7 | Tablepm1008dcpAlmsynthAlmLineTable | not-accessible | current | List of pm1008dcpAlmsynthAlmLine Article |
| 1.3.6.1.4.1.20044.27.2.3.3.7.1 | Rowpm1008dcpAlmsynthAlmLineEntry | not-accessible | current | Row definition for the pm1008dcpAlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.27.2.3.3.7.1.1 | Columnpm1008dcpAlmsynthAlmLineIndex | read-only | current | Index definition for the pm1008dcpAlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.27.2.3.3.7.1.2 | Columnpm1008dcpAlmXfpAbsentPortn | read-only | current | Line Optical Module Absent :This OID indicates that the line optical interface (XFP or OTX) is not plugged in. <Help> This alarm indicates if the line transcei… |
| 1.3.6.1.4.1.20044.27.2.3.3.7.1.3 | Columnpm1008dcpAlmXfpInitNotComplPortn | read-only | current | Line Optical Module Ready :This OID indicates that the optical interface (XFP or OTX) is not operational. <Help> This status indicates if the line transceiver … |
| 1.3.6.1.4.1.20044.27.2.3.3.7.1.5 | Columnpm1008dcpAlmLineHwFailPortn | read-only | current | Line Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Condtype> LINE_HW_FAIL <Probcause> equipmentMalfunction (1… |
| 1.3.6.1.4.1.20044.27.2.3.3.7.1.6 | Columnpm1008dcpAlmXfpTxOffPortn | read-only | current | Line Optical Module Laser Shutdown :This OID indicates the line optical output power is on <Help> This status indicates if the line transceiver laser is ON or … |
| 1.3.6.1.4.1.20044.27.2.3.3.7.1.7 | Columnpm1008dcpAlmLineLocalOosPortn | read-only | current | Line Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service… |
| 1.3.6.1.4.1.20044.27.2.3.3.7.1.9 | Columnpm1008dcpAlmUpRdiInsPortn | read-only | current | MS-RDI/L-RDI Inserted On Line :This OID indicates an upstream MS-RDI/L-RDI has been inserted in the outgoing 10 Gb/s SDH/SONET signal. <Help> This status indic… |
| 1.3.6.1.4.1.20044.27.2.3.3.7.1.10 | Columnpm1008dcpAlmLineDdmWarningPortn | read-only | current | Warning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Warni… |
| 1.3.6.1.4.1.20044.27.2.3.3.7.1.11 | Columnpm1008dcpAlmLineDdmAlmPortn | read-only | current | Alarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Alarm ha… |
| 1.3.6.1.4.1.20044.27.2.3.3.7.1.13 | Columnpm1008dcpAlmLineFailPortn | read-only | current | Line Port Failure :This OID indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12) <Po… |
| 1.3.6.1.4.1.20044.27.2.3.3.128 | Tablepm1008dcpAlmdfrmAlmTable | not-accessible | current | List of pm1008dcpAlmdfrmAlm Article |
| 1.3.6.1.4.1.20044.27.2.3.3.128.1 | Rowpm1008dcpAlmdfrmAlmEntry | not-accessible | current | Row definition for the pm1008dcpAlmdfrmAlm table |
| 1.3.6.1.4.1.20044.27.2.3.3.128.1.1 | Columnpm1008dcpAlmdfrmAlmIndex | read-only | current | Index definition for the pm1008dcpAlmdfrmAlm table |
| 1.3.6.1.4.1.20044.27.2.3.3.128.1.2 | Columnpm1008dcpAlmDwAisDetPortn | read-only | current | MS-AIS/L-AIS Detected On Line Input :This OID indicates that an MS-AIS has been detected on incoming OC-48c/STM-16c input signal <Help> This alarm indicates if… |
| 1.3.6.1.4.1.20044.27.2.3.3.128.1.3 | Columnpm1008dcpAlmDwRdiDetPortn | read-only | current | MS-RDI/L-RDI Detected On Line Input :This OID indicates that an MS-RDI has been detected on incoming OC-48c/STM-16c input signal <Help> This alarm indicates if… |
| 1.3.6.1.4.1.20044.27.2.3.3.128.1.4 | Columnpm1008dcpAlmDwOofPortn | read-only | current | SONET/SDH Line Out Of Frame :This OID indicates that an Out Of Frame has been detected on incoming OC-48c/STM-16c input signal <Help> This alarm indicates if t… |
| 1.3.6.1.4.1.20044.27.2.3.3.128.1.5 | Columnpm1008dcpAlmDwLofPortn | read-only | current | SONET/SDH Line Loss Of Frame :This OID indicates that a Loss Of Frame has been detected on incoming OC-48c/STM-16c input signal <Help> This alarm indicates if … |
| 1.3.6.1.4.1.20044.27.2.3.3.133 | Tablepm1008dcpAlmlineSyncAlarmsTable | not-accessible | current | List of pm1008dcpAlmlineSyncAlarms Article |
| 1.3.6.1.4.1.20044.27.2.3.3.133.1 | Rowpm1008dcpAlmlineSyncAlarmsEntry | not-accessible | current | Row definition for the pm1008dcpAlmlineSyncAlarms table |
| 1.3.6.1.4.1.20044.27.2.3.3.133.1.1 | Columnpm1008dcpAlmlineSyncAlarmsIndex | read-only | current | Index definition for the pm1008dcpAlmlineSyncAlarms table |
| 1.3.6.1.4.1.20044.27.2.3.3.133.1.13 | Columnpm1008dcpAlmDwLockerrPortn | read-only | current | Downstream Clock Lock Error :This OID indicates that the deserializer input 10 Gb/s clock recovery is not locked. <Condtype> DW_LOCKERR <Probcause> receiveFail… |
| 1.3.6.1.4.1.20044.27.2.3.3.133.1.14 | Columnpm1008dcpAlmUpLockerrPortn | read-only | current | Upstream Clock Lock Error :This OID indicates that the serializer output 10 Gb/s clock multiplier unit is not locked. <Condtype> UP_LOCKERR <Probcause> receive… |
| 1.3.6.1.4.1.20044.27.2.3.3.133.1.17 | Columnpm1008dcpAlmDwLosPortn | read-only | current | Line Input Loss Of Signal :This OID indicates a loss of signal on the 10 Gb/s input. <Help> This alarm indicates if an optical signal is detected on the line t… |
| 1.3.6.1.4.1.20044.27.2.3.3.211 | Tablepm1008dcpAlmlineXfp1AlarmsTable | not-accessible | current | List of pm1008dcpAlmlineXfp1Alarms Article |
| 1.3.6.1.4.1.20044.27.2.3.3.211.1 | Rowpm1008dcpAlmlineXfp1AlarmsEntry | not-accessible | current | Row definition for the pm1008dcpAlmlineXfp1Alarms table |
| 1.3.6.1.4.1.20044.27.2.3.3.211.1.1 | Columnpm1008dcpAlmlineXfp1AlarmsIndex | read-only | current | Index definition for the pm1008dcpAlmlineXfp1Alarms table |
| 1.3.6.1.4.1.20044.27.2.3.3.211.1.3 | Columnpm1008dcpAlmModNrPortn | read-only | current | Line Optical Module Not Ready :This OID indicates that the module is unable to determine correct data. <Help> This alarm indicates if the line transceiver is r… |
| 1.3.6.1.4.1.20044.27.2.3.3.211.1.4 | Columnpm1008dcpAlmRxCdrNotLockedPortn | read-only | current | Line Optical Rx CDR Unlocked :This OID indicates that a loss of lock on the receiving side CDR has been detected <Help> This alarm indicates if the Rx CDR is l… |
| 1.3.6.1.4.1.20044.27.2.3.3.211.1.6 | Columnpm1008dcpAlmRxNrPortn | read-only | current | Line Optical Rx Not Ready :This OID indicates that a condition has arisen leading to invalid data on the receiving side. <Help> This alarm indicates if the Rx … |
| 1.3.6.1.4.1.20044.27.2.3.3.211.1.7 | Columnpm1008dcpAlmTxCdrNotLockedPortn | read-only | current | Line Optical Tx CDR Unlocked :This OID indicates a loss of lock on the transmitting side CDR has been detected. <Help> This alarm indicates if the Tx CDR is lo… |
| 1.3.6.1.4.1.20044.27.2.3.3.211.1.8 | Columnpm1008dcpAlmTxFaultPortn | read-only | current | Line Optical Tx Failure :This OID indicates a fault condition on the laser detected by the safety syste <Help> This alarm indicates if the laser of the line tr… |
| 1.3.6.1.4.1.20044.27.2.3.3.211.1.9 | Columnpm1008dcpAlmTxNrPortn | read-only | current | Line Optical Tx Not Ready :This OID indicates a condition has arisen leading to invalid data on the transmitting side <Help> This alarm indicates if the Tx par… |
| 1.3.6.1.4.1.20044.27.2.3.3.211.1.11 | Columnpm1008dcpAlmChannelNotAcquiredPortn | read-only | current | DWDM Channel Not Acquired :This OID indicates the transceiver didn't tune the DWDM Channel succesfully. <Help> This status indicates the transceiver has not tu… |
| 1.3.6.1.4.1.20044.27.2.3.3.211.1.15 | Columnpm1008dcpAlmWavelengthUnlockedPortn | read-only | current | Line Optical Tx Wavelength Unlocked :This OID indicates that the wavelength error is exceeding the manufacturer tolerance <Help> This alarm indicates if the wa… |
| 1.3.6.1.4.1.20044.27.2.3.3.211.1.16 | Columnpm1008dcpAlmTecFaultPortn | read-only | current | Line Optical Tx Temp Regul Failed :This OID indicates a failure on the TEC module <Help> This alarm indicates if the TEC of the line transceiver is in fail con… |
| 1.3.6.1.4.1.20044.27.2.3.3.211.1.17 | Columnpm1008dcpAlmApdSupplyFaultPortn | read-only | current | Line Rx Photodiode Power Failed :This OID indicates a failure on the APD power supply <Help> This alarm indicates if the APD power supply is in fail condition … |
| 1.3.6.1.4.1.20044.27.3 | Nodepm1008dcpmeasures | |||
| 1.3.6.1.4.1.20044.27.3.1 | Nodepm1008dcpMesrOther | |||
| 1.3.6.1.4.1.20044.27.3.1.0 | Scalarpm1008dcpMesrsynth0 | read-only | deprecated | Not Used :This OID gives the unit used on AUX1 measurement of XFP (Unit = ) |
| 1.3.6.1.4.1.20044.27.3.1.1 | Scalarpm1008dcpMesrsynth1 | read-only | deprecated | Not Used :This OID gives the unit used on AUX2 measurement of XFP (Unit = ) |
| 1.3.6.1.4.1.20044.27.3.2 | Nodepm1008dcpMesrClient | |||
| 1.3.6.1.4.1.20044.27.3.2.16 | Tablepm1008dcpMesrtempMeasTable | not-accessible | current | List of pm1008dcpMesrtempMeas Article |
| 1.3.6.1.4.1.20044.27.3.2.16.1 | Rowpm1008dcpMesrtempMeasEntry | not-accessible | current | Row definition for the pm1008dcpMesrtempMeas table |
| 1.3.6.1.4.1.20044.27.3.2.16.1.1 | Columnpm1008dcpMesrtempMeasIndex | read-only | current | Index definition for the pm1008dcpMesrtempMeas table |
| 1.3.6.1.4.1.20044.27.3.2.16.1.2 | Columnpm1008dcpMesrtempMeasPortn | read-only | current | Client SFP Temperature :This OID gives the temperature value of the SFP plugged in port, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/25… |
| 1.3.6.1.4.1.20044.27.3.2.24 | Tablepm1008dcpMesrvoltMeasTable | not-accessible | current | List of pm1008dcpMesrvoltMeas Article |
| 1.3.6.1.4.1.20044.27.3.2.24.1 | Rowpm1008dcpMesrvoltMeasEntry | not-accessible | current | Row definition for the pm1008dcpMesrvoltMeas table |
| 1.3.6.1.4.1.20044.27.3.2.24.1.1 | Columnpm1008dcpMesrvoltMeasIndex | read-only | current | Index definition for the pm1008dcpMesrvoltMeas table |
| 1.3.6.1.4.1.20044.27.3.2.24.1.2 | Columnpm1008dcpMesrvoltMeasPortn | read-only | current | Client SFP Power Supply :This OID gives the 3V3 voltage value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/100… |
| 1.3.6.1.4.1.20044.27.3.2.32 | Tablepm1008dcpMesrbiasMeasTable | not-accessible | current | List of pm1008dcpMesrbiasMeas Article |
| 1.3.6.1.4.1.20044.27.3.2.32.1 | Rowpm1008dcpMesrbiasMeasEntry | not-accessible | current | Row definition for the pm1008dcpMesrbiasMeas table |
| 1.3.6.1.4.1.20044.27.3.2.32.1.1 | Columnpm1008dcpMesrbiasMeasIndex | read-only | current | Index definition for the pm1008dcpMesrbiasMeas table |
| 1.3.6.1.4.1.20044.27.3.2.32.1.2 | Columnpm1008dcpMesrbiasMeasPortn | read-only | current | Client SFP Laser Bias :This OID gives the bias value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA… |
| 1.3.6.1.4.1.20044.27.3.2.40 | Tablepm1008dcpMesrtxpwrMeasTable | not-accessible | current | List of pm1008dcpMesrtxpwrMeas Article |
| 1.3.6.1.4.1.20044.27.3.2.40.1 | Rowpm1008dcpMesrtxpwrMeasEntry | not-accessible | current | Row definition for the pm1008dcpMesrtxpwrMeas table |
| 1.3.6.1.4.1.20044.27.3.2.40.1.1 | Columnpm1008dcpMesrtxpwrMeasIndex | read-only | current | Index definition for the pm1008dcpMesrtxpwrMeas table |
| 1.3.6.1.4.1.20044.27.3.2.40.1.2 | Columnpm1008dcpMesrtxpwrMeasPortn | read-only | current | Client SFP Tx Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV… |
| 1.3.6.1.4.1.20044.27.3.2.48 | Tablepm1008dcpMesrrxpwrMeasTable | not-accessible | current | List of pm1008dcpMesrrxpwrMeas Article |
| 1.3.6.1.4.1.20044.27.3.2.48.1 | Rowpm1008dcpMesrrxpwrMeasEntry | not-accessible | current | Row definition for the pm1008dcpMesrrxpwrMeas table |
| 1.3.6.1.4.1.20044.27.3.2.48.1.1 | Columnpm1008dcpMesrrxpwrMeasIndex | read-only | current | Index definition for the pm1008dcpMesrrxpwrMeas table |
| 1.3.6.1.4.1.20044.27.3.2.48.1.2 | Columnpm1008dcpMesrrxpwrMeasPortn | read-only | current | Client SFP Rx Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-4… |
| 1.3.6.1.4.1.20044.27.3.3 | Nodepm1008dcpMesrLine | |||
| 1.3.6.1.4.1.20044.27.3.3.208 | Tablepm1008dcpMesrxfp1LxModTempMeasTable | not-accessible | current | List of pm1008dcpMesrxfp1LxModTempMeas Article |
| 1.3.6.1.4.1.20044.27.3.3.208.1 | Rowpm1008dcpMesrxfp1LxModTempMeasEntry | not-accessible | current | Row definition for the pm1008dcpMesrxfp1LxModTempMeas table |
| 1.3.6.1.4.1.20044.27.3.3.208.1.1 | Columnpm1008dcpMesrxfp1LxModTempMeasIndex | read-only | current | Index definition for the pm1008dcpMesrxfp1LxModTempMeas table |
| 1.3.6.1.4.1.20044.27.3.3.208.1.2 | Columnpm1008dcpMesrxfp1LxModTempMeasPortn | read-only | current | Line Optical Module Temperature :This OID gives the temperature of the XFP or OTX plugged in line, read from the DDM (Digital Diagnostic Monitoring) (Temperatu… |
| 1.3.6.1.4.1.20044.27.3.3.209 | Tablepm1008dcpMesrxfp1ReservedTable | not-accessible | deprecated | List of pm1008dcpMesrxfp1Reserved Article |
| 1.3.6.1.4.1.20044.27.3.3.209.1 | Rowpm1008dcpMesrxfp1ReservedEntry | not-accessible | deprecated | Row definition for the pm1008dcpMesrxfp1Reserved table |
| 1.3.6.1.4.1.20044.27.3.3.209.1.1 | Columnpm1008dcpMesrxfp1ReservedIndex | read-only | deprecated | Index definition for the pm1008dcpMesrxfp1Reserved table |
| 1.3.6.1.4.1.20044.27.3.3.209.1.2 | Columnpm1008dcpMesrxfp1ReservedPortn | read-only | deprecated | Not Used :Reserved |
| 1.3.6.1.4.1.20044.27.3.3.210 | Tablepm1008dcpMesrxfp1LoBiasCurrentMeasTable | not-accessible | current | List of pm1008dcpMesrxfp1LoBiasCurrentMeas Article |
| 1.3.6.1.4.1.20044.27.3.3.210.1 | Rowpm1008dcpMesrxfp1LoBiasCurrentMeasEntry | not-accessible | current | Row definition for the pm1008dcpMesrxfp1LoBiasCurrentMeas table |
| 1.3.6.1.4.1.20044.27.3.3.210.1.1 | Columnpm1008dcpMesrxfp1LoBiasCurrentMeasIndex | read-only | current | Index definition for the pm1008dcpMesrxfp1LoBiasCurrentMeas table |
| 1.3.6.1.4.1.20044.27.3.3.210.1.2 | Columnpm1008dcpMesrxfp1LoBiasCurrentMeasPortn | read-only | current | Line Optical Module Laser Bias :This OID gives the bias value of the XFP or OTX plugged in line , read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/… |
| 1.3.6.1.4.1.20044.27.3.3.211 | Tablepm1008dcpMesrxfp1LoTxPowerMeasTable | not-accessible | current | List of pm1008dcpMesrxfp1LoTxPowerMeas Article |
| 1.3.6.1.4.1.20044.27.3.3.211.1 | Rowpm1008dcpMesrxfp1LoTxPowerMeasEntry | not-accessible | current | Row definition for the pm1008dcpMesrxfp1LoTxPowerMeas table |
| 1.3.6.1.4.1.20044.27.3.3.211.1.1 | Columnpm1008dcpMesrxfp1LoTxPowerMeasIndex | read-only | current | Index definition for the pm1008dcpMesrxfp1LoTxPowerMeas table |
| 1.3.6.1.4.1.20044.27.3.3.211.1.2 | Columnpm1008dcpMesrxfp1LoTxPowerMeasPortn | read-only | current | Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line , read from the DDM (Digital Diagnostic Monitoring) (Po… |
| 1.3.6.1.4.1.20044.27.3.3.212 | Tablepm1008dcpMesrxfp1LiRxPowerMeasTable | not-accessible | current | List of pm1008dcpMesrxfp1LiRxPowerMeas Article |
| 1.3.6.1.4.1.20044.27.3.3.212.1 | Rowpm1008dcpMesrxfp1LiRxPowerMeasEntry | not-accessible | current | Row definition for the pm1008dcpMesrxfp1LiRxPowerMeas table |
| 1.3.6.1.4.1.20044.27.3.3.212.1.1 | Columnpm1008dcpMesrxfp1LiRxPowerMeasIndex | read-only | current | Index definition for the pm1008dcpMesrxfp1LiRxPowerMeas table |
| 1.3.6.1.4.1.20044.27.3.3.212.1.2 | Columnpm1008dcpMesrxfp1LiRxPowerMeasPortn | read-only | current | Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line , read from the DDM (Digital Diagnostic Monitoring) (Pow… |
| 1.3.6.1.4.1.20044.27.3.3.213 | Tablepm1008dcpMesrxfp1LxAux1MeasTable | not-accessible | deprecated | List of pm1008dcpMesrxfp1LxAux1Meas Article |
| 1.3.6.1.4.1.20044.27.3.3.213.1 | Rowpm1008dcpMesrxfp1LxAux1MeasEntry | not-accessible | deprecated | Row definition for the pm1008dcpMesrxfp1LxAux1Meas table |
| 1.3.6.1.4.1.20044.27.3.3.213.1.1 | Columnpm1008dcpMesrxfp1LxAux1MeasIndex | read-only | deprecated | Index definition for the pm1008dcpMesrxfp1LxAux1Meas table |
| 1.3.6.1.4.1.20044.27.3.3.213.1.2 | Columnpm1008dcpMesrxfp1LxAux1MeasPortn | read-only | deprecated | Not Used :This OID gives the receive power value read in the DDM (Digital Diagnostic Monitoring) of the XFP or OTX plugged in line (Unit = ?) |
| 1.3.6.1.4.1.20044.27.3.3.214 | Tablepm1008dcpMesrxfp1LxAux2MeasTable | not-accessible | deprecated | List of pm1008dcpMesrxfp1LxAux2Meas Article |
| 1.3.6.1.4.1.20044.27.3.3.214.1 | Rowpm1008dcpMesrxfp1LxAux2MeasEntry | not-accessible | deprecated | Row definition for the pm1008dcpMesrxfp1LxAux2Meas table |
| 1.3.6.1.4.1.20044.27.3.3.214.1.1 | Columnpm1008dcpMesrxfp1LxAux2MeasIndex | read-only | deprecated | Index definition for the pm1008dcpMesrxfp1LxAux2Meas table |
| 1.3.6.1.4.1.20044.27.3.3.214.1.2 | Columnpm1008dcpMesrxfp1LxAux2MeasPortn | read-only | deprecated | Not Used :This OID gives the receive power value read in the DDM (Digital Diagnostic Monitoring) of the XFP or OTX plugged in line (Unit = ?) |
| 1.3.6.1.4.1.20044.27.3.3.224 | Tablepm1008dcpMesrotx1AgingTable | not-accessible | current | List of pm1008dcpMesrotx1Aging Article |
| 1.3.6.1.4.1.20044.27.3.3.224.1 | Rowpm1008dcpMesrotx1AgingEntry | not-accessible | current | Row definition for the pm1008dcpMesrotx1Aging table |
| 1.3.6.1.4.1.20044.27.3.3.224.1.1 | Columnpm1008dcpMesrotx1AgingIndex | read-only | current | Index definition for the pm1008dcpMesrotx1Aging table |
| 1.3.6.1.4.1.20044.27.3.3.224.1.2 | Columnpm1008dcpMesrotx1AgingPortn | read-only | current | Line OTX TLH Aging :This OID gives the aging of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Aging = AV) (Unit = %) <Help> This measure… |
| 1.3.6.1.4.1.20044.27.3.3.225 | Tablepm1008dcpMesrotx1LaserTemperatureTable | not-accessible | deprecated | List of pm1008dcpMesrotx1LaserTemperature Article |
| 1.3.6.1.4.1.20044.27.3.3.225.1 | Rowpm1008dcpMesrotx1LaserTemperatureEntry | not-accessible | deprecated | Row definition for the pm1008dcpMesrotx1LaserTemperature table |
| 1.3.6.1.4.1.20044.27.3.3.225.1.1 | Columnpm1008dcpMesrotx1LaserTemperatureIndex | read-only | deprecated | Index definition for the pm1008dcpMesrotx1LaserTemperature table |
| 1.3.6.1.4.1.20044.27.3.3.225.1.2 | Columnpm1008dcpMesrotx1LaserTemperaturePortn | read-only | deprecated | Line OTX TLH Laser Temperature :This OID gives the laser temperature of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/2… |
| 1.3.6.1.4.1.20044.27.3.3.226 | Tablepm1008dcpMesrotx1FreqDeviationTable | not-accessible | current | List of pm1008dcpMesrotx1FreqDeviation Article |
| 1.3.6.1.4.1.20044.27.3.3.226.1 | Rowpm1008dcpMesrotx1FreqDeviationEntry | not-accessible | current | Row definition for the pm1008dcpMesrotx1FreqDeviation table |
| 1.3.6.1.4.1.20044.27.3.3.226.1.1 | Columnpm1008dcpMesrotx1FreqDeviationIndex | read-only | current | Index definition for the pm1008dcpMesrotx1FreqDeviation table |
| 1.3.6.1.4.1.20044.27.3.3.226.1.2 | Columnpm1008dcpMesrotx1FreqDeviationPortn | read-only | current | Line OTX TLH Frequency Deviation :This OID gives the frequency deviation of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Deviation = (A… |
| 1.3.6.1.4.1.20044.27.3.3.227 | Tablepm1008dcpMesrotx1LaserWvlengthTable | not-accessible | current | List of pm1008dcpMesrotx1LaserWvlength Article |
| 1.3.6.1.4.1.20044.27.3.3.227.1 | Rowpm1008dcpMesrotx1LaserWvlengthEntry | not-accessible | current | Row definition for the pm1008dcpMesrotx1LaserWvlength table |
| 1.3.6.1.4.1.20044.27.3.3.227.1.1 | Columnpm1008dcpMesrotx1LaserWvlengthIndex | read-only | current | Index definition for the pm1008dcpMesrotx1LaserWvlength table |
| 1.3.6.1.4.1.20044.27.3.3.227.1.2 | Columnpm1008dcpMesrotx1LaserWvlengthPortn | read-only | current | Line Optical Module Wavelength :This OID gives the laser wavelength of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Wavelength=29979245… |
| 1.3.6.1.4.1.20044.27.4 | Nodepm1008dcpcounters | |||
| 1.3.6.1.4.1.20044.27.4.1 | Nodepm1008dcpCntOther | |||
| 1.3.6.1.4.1.20044.27.4.2 | Nodepm1008dcpCntClient | |||
| 1.3.6.1.4.1.20044.27.4.2.16 | Tablepm1008dcpCntupRaRemCntTable | not-accessible | current | List of pm1008dcpCntupRaRemCnt Article |
| 1.3.6.1.4.1.20044.27.4.2.16.1 | Rowpm1008dcpCntupRaRemCntEntry | not-accessible | current | Row definition for the pm1008dcpCntupRaRemCnt table |
| 1.3.6.1.4.1.20044.27.4.2.16.1.1 | Columnpm1008dcpCntupRaRemCntIndex | read-only | current | Index definition for the pm1008dcpCntupRaRemCnt table |
| 1.3.6.1.4.1.20044.27.4.2.16.1.2 | Columnpm1008dcpCntupRaRemCntValuePortn | read-only | current | Client Rate Adapt. Words Removal :This counter is incremented each time a rate adaptation 10B word is removed from the Client input stream |
| 1.3.6.1.4.1.20044.27.4.2.16.1.3 | Columnpm1008dcpCntupRaRemCntErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the rate adaptation removal counter value is invalid on Port |
| 1.3.6.1.4.1.20044.27.4.2.16.1.4 | Columnpm1008dcpCntupRaRemCntOverloadPortn | read-only | current | Client Counter Overload :This OID when set indicates a rate adaptation removal counter overload on Port |
| 1.3.6.1.4.1.20044.27.4.2.24 | Tablepm1008dcpCntupRaInsCntTable | not-accessible | current | List of pm1008dcpCntupRaInsCnt Article |
| 1.3.6.1.4.1.20044.27.4.2.24.1 | Rowpm1008dcpCntupRaInsCntEntry | not-accessible | current | Row definition for the pm1008dcpCntupRaInsCnt table |
| 1.3.6.1.4.1.20044.27.4.2.24.1.1 | Columnpm1008dcpCntupRaInsCntIndex | read-only | current | Index definition for the pm1008dcpCntupRaInsCnt table |
| 1.3.6.1.4.1.20044.27.4.2.24.1.2 | Columnpm1008dcpCntupRaInsCntValuePortn | read-only | current | Client Rate Adapt. Words Insertion :This counter is incremented each time a rate adaptation 10B word is inserted in the Client input stream |
| 1.3.6.1.4.1.20044.27.4.2.24.1.3 | Columnpm1008dcpCntupRaInsCntErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the rate adaptation insertion counter value is invalid on Port |
| 1.3.6.1.4.1.20044.27.4.2.24.1.4 | Columnpm1008dcpCntupRaInsCntOverloadPortn | read-only | current | Client Counter Overload :This OID when set indicates a rate adaptation insertion counter overload on Port |
| 1.3.6.1.4.1.20044.27.4.2.32 | Tablepm1008dcpCntupRdErrCntTable | not-accessible | current | List of pm1008dcpCntupRdErrCnt Article |
| 1.3.6.1.4.1.20044.27.4.2.32.1 | Rowpm1008dcpCntupRdErrCntEntry | not-accessible | current | Row definition for the pm1008dcpCntupRdErrCnt table |
| 1.3.6.1.4.1.20044.27.4.2.32.1.1 | Columnpm1008dcpCntupRdErrCntIndex | read-only | current | Index definition for the pm1008dcpCntupRdErrCnt table |
| 1.3.6.1.4.1.20044.27.4.2.32.1.2 | Columnpm1008dcpCntupRdErrCntValuePortn | read-only | current | Client Input Errors :This counter is increased each time a 10b/8b running disparity error is detected on the Client input stream <Help> This counter gives the … |
| 1.3.6.1.4.1.20044.27.4.2.32.1.3 | Columnpm1008dcpCntupRdErrCntErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the client error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.27.4.2.32.1.4 | Columnpm1008dcpCntupRdErrCntOverloadPortn | read-only | current | Client Counter Overload :This OID when set indicates a client input error counter overload on Port |
| 1.3.6.1.4.1.20044.27.4.2.40 | Tablepm1008dcpCntupTimCntTable | not-accessible | current | List of pm1008dcpCntupTimCnt Article |
| 1.3.6.1.4.1.20044.27.4.2.40.1 | Rowpm1008dcpCntupTimCntEntry | not-accessible | current | Row definition for the pm1008dcpCntupTimCnt table |
| 1.3.6.1.4.1.20044.27.4.2.40.1.1 | Columnpm1008dcpCntupTimCntIndex | read-only | current | Index definition for the pm1008dcpCntupTimCnt table |
| 1.3.6.1.4.1.20044.27.4.2.40.1.2 | Columnpm1008dcpCntupTimCntValuePortn | read-only | current | Client Upstream Timer Counter :This is the timing counter dedicated to the upstream access counters. It is incremented every 125 us. |
| 1.3.6.1.4.1.20044.27.4.2.40.1.3 | Columnpm1008dcpCntupTimCntErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the upstream timing counter value is invalid on Port |
| 1.3.6.1.4.1.20044.27.4.2.40.1.4 | Columnpm1008dcpCntupTimCntOverloadPortn | read-only | current | Client Counter Overload :This OID when set indicates a upstream timing counter overload on Port |
| 1.3.6.1.4.1.20044.27.4.2.48 | Tablepm1008dcpCntupCvErrCntTable | not-accessible | current | List of pm1008dcpCntupCvErrCnt Article |
| 1.3.6.1.4.1.20044.27.4.2.48.1 | Rowpm1008dcpCntupCvErrCntEntry | not-accessible | current | Row definition for the pm1008dcpCntupCvErrCnt table |
| 1.3.6.1.4.1.20044.27.4.2.48.1.1 | Columnpm1008dcpCntupCvErrCntIndex | read-only | current | Index definition for the pm1008dcpCntupCvErrCnt table |
| 1.3.6.1.4.1.20044.27.4.2.48.1.2 | Columnpm1008dcpCntupCvErrCntValuePortn | read-only | current | Client Coding Violation Counter :This counter is increased each time a 10b/8b coding violation is detected on the Client input stream |
| 1.3.6.1.4.1.20044.27.4.2.48.1.3 | Columnpm1008dcpCntupCvErrCntErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the coding violation counter value is invalid on Port |
| 1.3.6.1.4.1.20044.27.4.2.48.1.4 | Columnpm1008dcpCntupCvErrCntOverloadPortn | read-only | current | Client Counter Overload :This OID when set indicates a coding violation counter overload on Port |
| 1.3.6.1.4.1.20044.27.4.2.64 | Tablepm1008dcpCntdwCbipCntTable | not-accessible | current | List of pm1008dcpCntdwCbipCnt Article |
| 1.3.6.1.4.1.20044.27.4.2.64.1 | Rowpm1008dcpCntdwCbipCntEntry | not-accessible | current | Row definition for the pm1008dcpCntdwCbipCnt table |
| 1.3.6.1.4.1.20044.27.4.2.64.1.1 | Columnpm1008dcpCntdwCbipCntIndex | read-only | current | Index definition for the pm1008dcpCntdwCbipCnt table |
| 1.3.6.1.4.1.20044.27.4.2.64.1.2 | Columnpm1008dcpCntdwCbipCntValuePortn | read-only | current | Client Output Errors :This counter is incremented each time a CBIP parity error is detected on the Client output stream <Help> This counter gives the number of… |
| 1.3.6.1.4.1.20044.27.4.2.64.1.3 | Columnpm1008dcpCntdwCbipCntErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the CBIP error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.27.4.2.64.1.4 | Columnpm1008dcpCntdwCbipCntOverloadPortn | read-only | current | Client CBIP Counter Overload :This OID when set indicates a CBIP error counter overload on Port |
| 1.3.6.1.4.1.20044.27.4.2.72 | Tablepm1008dcpCntdwTimCntTable | not-accessible | current | List of pm1008dcpCntdwTimCnt Article |
| 1.3.6.1.4.1.20044.27.4.2.72.1 | Rowpm1008dcpCntdwTimCntEntry | not-accessible | current | Row definition for the pm1008dcpCntdwTimCnt table |
| 1.3.6.1.4.1.20044.27.4.2.72.1.1 | Columnpm1008dcpCntdwTimCntIndex | read-only | current | Index definition for the pm1008dcpCntdwTimCnt table |
| 1.3.6.1.4.1.20044.27.4.2.72.1.2 | Columnpm1008dcpCntdwTimCntValuePortn | read-only | current | Client Downstream Timer Counter :This is the timing counter dedicated to the downstream access counters. It is incremented every 125 us. |
| 1.3.6.1.4.1.20044.27.4.2.72.1.3 | Columnpm1008dcpCntdwTimCntErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the downstream timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.27.4.2.72.1.4 | Columnpm1008dcpCntdwTimCntOverloadPortn | read-only | current | Client Counter Overload :This OID when set indicates a downstream timer counter overload on Port |
| 1.3.6.1.4.1.20044.27.4.3 | Nodepm1008dcpCntLine | |||
| 1.3.6.1.4.1.20044.27.4.3.152 | Tablepm1008dcpCntdfrmB1ErrCntTable | not-accessible | current | List of pm1008dcpCntdfrmB1ErrCnt Article |
| 1.3.6.1.4.1.20044.27.4.3.152.1 | Rowpm1008dcpCntdfrmB1ErrCntEntry | not-accessible | current | Row definition for the pm1008dcpCntdfrmB1ErrCnt table |
| 1.3.6.1.4.1.20044.27.4.3.152.1.1 | Columnpm1008dcpCntdfrmB1ErrCntIndex | read-only | current | Index definition for the pm1008dcpCntdfrmB1ErrCnt table |
| 1.3.6.1.4.1.20044.27.4.3.152.1.2 | Columnpm1008dcpCntdfrmB1ErrCntValuePortn | read-only | current | Line Input B1 Errors :This counter is incremented each time a B1 error is detected on the Deframer input stream. <Help> This counter gives the number of B1 err… |
| 1.3.6.1.4.1.20044.27.4.3.152.1.3 | Columnpm1008dcpCntdfrmB1ErrCntErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the B1 error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.27.4.3.152.1.4 | Columnpm1008dcpCntdfrmB1ErrCntOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a B1 error counter overload on Port |
| 1.3.6.1.4.1.20044.27.4.3.153 | Tablepm1008dcpCntdfrmTimCntTable | not-accessible | current | List of pm1008dcpCntdfrmTimCnt Article |
| 1.3.6.1.4.1.20044.27.4.3.153.1 | Rowpm1008dcpCntdfrmTimCntEntry | not-accessible | current | Row definition for the pm1008dcpCntdfrmTimCnt table |
| 1.3.6.1.4.1.20044.27.4.3.153.1.1 | Columnpm1008dcpCntdfrmTimCntIndex | read-only | current | Index definition for the pm1008dcpCntdfrmTimCnt table |
| 1.3.6.1.4.1.20044.27.4.3.153.1.2 | Columnpm1008dcpCntdfrmTimCntValuePortn | read-only | current | Line Timer Counter :This is the timing counter dedicated to the downstream deframer counters. It is incremented every 125 us. |
| 1.3.6.1.4.1.20044.27.4.3.153.1.3 | Columnpm1008dcpCntdfrmTimCntErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.27.4.3.153.1.4 | Columnpm1008dcpCntdfrmTimCntOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.27.4.3.154 | Tablepm1008dcpCntdfrmPrimLineErrCntTable | not-accessible | current | List of pm1008dcpCntdfrmPrimLineErrCnt Article |
| 1.3.6.1.4.1.20044.27.4.3.154.1 | Rowpm1008dcpCntdfrmPrimLineErrCntEntry | not-accessible | current | Row definition for the pm1008dcpCntdfrmPrimLineErrCnt table |
| 1.3.6.1.4.1.20044.27.4.3.154.1.1 | Columnpm1008dcpCntdfrmPrimLineErrCntIndex | read-only | current | Index definition for the pm1008dcpCntdfrmPrimLineErrCnt table |
| 1.3.6.1.4.1.20044.27.4.3.154.1.2 | Columnpm1008dcpCntdfrmPrimLineErrCntValuePortn | read-only | current | Line Input FEC Corrected Errors :This counter is incremented each time the FEC is correcting an error on the line input stream. <Help> This counter gives the n… |
| 1.3.6.1.4.1.20044.27.4.3.154.1.3 | Columnpm1008dcpCntdfrmPrimLineErrCntErrorPortn | read-only | current | FEC Counter Error :This bit when set indicates the FEC corrected errors counter value is invalid on Line |
| 1.3.6.1.4.1.20044.27.4.3.154.1.4 | Columnpm1008dcpCntdfrmPrimLineErrCntOverloadPortn | read-only | current | FEC Counter Overload :This bit when set indicates a FEC corrected errors counter overload on Line |
| 1.3.6.1.4.1.20044.27.4.259 | Scalarpm1008dcpCntCountersReset | read-write | current | Counters Reset:This OID resets and restarts all the counters |
| 1.3.6.1.4.1.20044.27.4.260 | Scalarpm1008dcpCntCountersStop | read-write | current | Counters stop:This OID stops all the counters |
| 1.3.6.1.4.1.20044.27.6 | Nodepm1008dcpcontrolsWrite | |||
| 1.3.6.1.4.1.20044.27.6.1 | Nodepm1008dcpCtrlOther | |||
| 1.3.6.1.4.1.20044.27.6.1.1 | Nodepm1008dcpCtrlconfMgnt1 | |||
| 1.3.6.1.4.1.20044.27.6.1.1.1 | Scalarpm1008dcpCtrlConf1Load1 | read-write | current | Load Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM. |
| 1.3.6.1.4.1.20044.27.6.1.1.2 | Scalarpm1008dcpCtrlConf2Load1 | read-write | current | Load Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM. |
| 1.3.6.1.4.1.20044.27.6.1.1.10 | Scalarpm1008dcpCtrlConf2Flash1 | read-write | current | Write Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura… |
| 1.3.6.1.4.1.20044.27.6.1.1.14 | Scalarpm1008dcpCtrlConf2Clear1 | read-write | current | Clear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o… |
| 1.3.6.1.4.1.20044.27.6.1.4 | Nodepm1008dcpCtrlsynth4 | |||
| 1.3.6.1.4.1.20044.27.6.1.4.1 | Scalarpm1008dcpCtrlCorrelatOn | read-write | current | Enable Alarm Correlation :This OID enables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.27.6.1.4.2 | Scalarpm1008dcpCtrlCorrelatOff | read-write | current | Disable Alarm Correlation :This OID disables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.27.6.1.5 | Nodepm1008dcpCtrlswMgnt | |||
| 1.3.6.1.4.1.20044.27.6.1.5.2 | Scalarpm1008dcpCtrlColdReset | read-write | current | PM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> … |
| 1.3.6.1.4.1.20044.27.6.1.5.3 | Scalarpm1008dcpCtrlWarmReset | read-write | current | PM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th… |
| 1.3.6.1.4.1.20044.27.6.1.5.5 | Scalarpm1008dcpCtrlLoadSwBank1 | read-write | current | Set Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW… |
| 1.3.6.1.4.1.20044.27.6.1.5.6 | Scalarpm1008dcpCtrlLoadSwBank2 | read-write | current | Set Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S… |
| 1.3.6.1.4.1.20044.27.6.1.6 | Nodepm1008dcpCtrlgwMgnt | |||
| 1.3.6.1.4.1.20044.27.6.1.6.1 | Scalarpm1008dcpCtrlCurrentGwReset | read-write | current | Active Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting. |
| 1.3.6.1.4.1.20044.27.6.1.6.5 | Scalarpm1008dcpCtrlLoadGwBank1 | read-write | current | Set Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.27.6.1.6.6 | Scalarpm1008dcpCtrlLoadGwBank2 | read-write | current | Set Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.27.6.1.6.7 | Scalarpm1008dcpCtrlLoadGwBank3 | read-write | current | Set Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.27.6.1.6.8 | Scalarpm1008dcpCtrlLoadGwBank4 | read-write | current | Set Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.27.6.1.192 | Nodepm1008dcpCtrlledTest | |||
| 1.3.6.1.4.1.20044.27.6.1.192.1 | Scalarpm1008dcpCtrlGreenLed | read-write | current | Green Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green |
| 1.3.6.1.4.1.20044.27.6.1.192.2 | Scalarpm1008dcpCtrlRedLed | read-write | current | Red Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red |
| 1.3.6.1.4.1.20044.27.6.1.192.3 | Scalarpm1008dcpCtrlLedOff | read-write | current | Leds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF |
| 1.3.6.1.4.1.20044.27.6.1.193 | Nodepm1008dcpCtrlmoduleOosMode | |||
| 1.3.6.1.4.1.20044.27.6.1.193.1 | Scalarpm1008dcpCtrlModuleOosMode | read-write | current | PM Out Of Service :This OID sets the PM Out Of Service <Help> This control defines the service state of the complete module |
| 1.3.6.1.4.1.20044.27.6.1.196 | Scalarpm1008dcpCtrlmoduleDccMgnt | read-write | current | DCC Mode :This OID defines the DCC mode of the PM (No DCC, Master, Slave Line 1&2, Terminal Line 1, Terminal Line 2, Terminal Line 1&2) <Help> This control def… |
| 1.3.6.1.4.1.20044.27.6.1.197 | Nodepm1008dcpCtrlmaintenanceMode | |||
| 1.3.6.1.4.1.20044.27.6.1.197.1 | Scalarpm1008dcpCtrlMaintenanceMode | read-write | current | Module Maintenance Mode :This OID enables the maintenance mode on the PM. <Help> This control enables the maintenance mode on the PM. |
| 1.3.6.1.4.1.20044.27.6.2 | Nodepm1008dcpCtrlClient | |||
| 1.3.6.1.4.1.20044.27.6.2.16 | Tablepm1008dcpCtrlaccessLoopTable | not-accessible | current | List of pm1008dcpCtrlaccessLoop Article |
| 1.3.6.1.4.1.20044.27.6.2.16.1 | Rowpm1008dcpCtrlaccessLoopEntry | not-accessible | current | Row definition for the pm1008dcpCtrlaccessLoop table |
| 1.3.6.1.4.1.20044.27.6.2.16.1.1 | Columnpm1008dcpCtrlaccessLoopIndex | read-only | current | Index definition for the pm1008dcpCtrlaccessLoop table |
| 1.3.6.1.4.1.20044.27.6.2.16.1.2 | Columnpm1008dcpCtrlaccessLoopPortn | read-write | current | Client Facility Loopback :This OID operates a Client Facility Loopback, looping client input signal on the client output port. The loop is located on the clien… |
| 1.3.6.1.4.1.20044.27.6.2.18 | Tablepm1008dcpCtrlportOosModeTable | not-accessible | current | List of pm1008dcpCtrlportOosMode Article |
| 1.3.6.1.4.1.20044.27.6.2.18.1 | Rowpm1008dcpCtrlportOosModeEntry | not-accessible | current | Row definition for the pm1008dcpCtrlportOosMode table |
| 1.3.6.1.4.1.20044.27.6.2.18.1.1 | Columnpm1008dcpCtrlportOosModeIndex | read-only | current | Index definition for the pm1008dcpCtrlportOosMode table |
| 1.3.6.1.4.1.20044.27.6.2.18.1.2 | Columnpm1008dcpCtrlportOosModePortn | read-write | current | Client Port Out Of Service :This OID sets the client port Out Of Service <Help> This controls defines the service state of the client port |
| 1.3.6.1.4.1.20044.27.6.2.19 | Tablepm1008dcpCtrlsfpOnCtrlTable | not-accessible | current | List of pm1008dcpCtrlsfpOnCtrl Article |
| 1.3.6.1.4.1.20044.27.6.2.19.1 | Rowpm1008dcpCtrlsfpOnCtrlEntry | not-accessible | current | Row definition for the pm1008dcpCtrlsfpOnCtrl table |
| 1.3.6.1.4.1.20044.27.6.2.19.1.1 | Columnpm1008dcpCtrlsfpOnCtrlIndex | read-only | current | Index definition for the pm1008dcpCtrlsfpOnCtrl table |
| 1.3.6.1.4.1.20044.27.6.2.19.1.2 | Columnpm1008dcpCtrlsfpOnCtrlPortn | read-write | current | Client SFP Optical Laser ON :This OID switches on the SFP. |
| 1.3.6.1.4.1.20044.27.6.2.20 | Tablepm1008dcpCtrlsfpOffCtrlTable | not-accessible | current | List of pm1008dcpCtrlsfpOffCtrl Article |
| 1.3.6.1.4.1.20044.27.6.2.20.1 | Rowpm1008dcpCtrlsfpOffCtrlEntry | not-accessible | current | Row definition for the pm1008dcpCtrlsfpOffCtrl table |
| 1.3.6.1.4.1.20044.27.6.2.20.1.1 | Columnpm1008dcpCtrlsfpOffCtrlIndex | read-only | current | Index definition for the pm1008dcpCtrlsfpOffCtrl table |
| 1.3.6.1.4.1.20044.27.6.2.20.1.2 | Columnpm1008dcpCtrlsfpOffCtrlPortn | read-write | current | Client SFP Laser Shutdown :This OID switches off the SFP. <Help> This control defines the laser state of the client transceiver |
| 1.3.6.1.4.1.20044.27.6.2.21 | Tablepm1008dcpCtrlcsfUpInsTable | not-accessible | current | List of pm1008dcpCtrlcsfUpIns Article |
| 1.3.6.1.4.1.20044.27.6.2.21.1 | Rowpm1008dcpCtrlcsfUpInsEntry | not-accessible | current | Row definition for the pm1008dcpCtrlcsfUpIns table |
| 1.3.6.1.4.1.20044.27.6.2.21.1.1 | Columnpm1008dcpCtrlcsfUpInsIndex | read-only | current | Index definition for the pm1008dcpCtrlcsfUpIns table |
| 1.3.6.1.4.1.20044.27.6.2.21.1.2 | Columnpm1008dcpCtrlcsfUpInsPortn | read-write | current | Client Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo… |
| 1.3.6.1.4.1.20044.27.6.2.22 | Tablepm1008dcpCtrlcaisDwInsTable | not-accessible | current | List of pm1008dcpCtrlcaisDwIns Article |
| 1.3.6.1.4.1.20044.27.6.2.22.1 | Rowpm1008dcpCtrlcaisDwInsEntry | not-accessible | current | Row definition for the pm1008dcpCtrlcaisDwIns table |
| 1.3.6.1.4.1.20044.27.6.2.22.1.1 | Columnpm1008dcpCtrlcaisDwInsIndex | read-only | current | Index definition for the pm1008dcpCtrlcaisDwIns table |
| 1.3.6.1.4.1.20044.27.6.2.22.1.2 | Columnpm1008dcpCtrlcaisDwInsPortn | read-write | current | Client AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port |
| 1.3.6.1.4.1.20044.27.6.2.26 | Tablepm1008dcpCtrlclientAccessTermLoopTable | not-accessible | current | List of pm1008dcpCtrlclientAccessTermLoop Article |
| 1.3.6.1.4.1.20044.27.6.2.26.1 | Rowpm1008dcpCtrlclientAccessTermLoopEntry | not-accessible | current | Row definition for the pm1008dcpCtrlclientAccessTermLoop table |
| 1.3.6.1.4.1.20044.27.6.2.26.1.1 | Columnpm1008dcpCtrlclientAccessTermLoopIndex | read-only | current | Index definition for the pm1008dcpCtrlclientAccessTermLoop table |
| 1.3.6.1.4.1.20044.27.6.2.26.1.2 | Columnpm1008dcpCtrlclientAccessTermLoopPortn | read-write | current | Client Terminal Loopback :This OID operates a Client Terminal Loopback, looping client input signal on the client output port. The loop is located on the line … |
| 1.3.6.1.4.1.20044.27.6.2.48 | Tablepm1008dcpCtrlprotocolTable | not-accessible | current | List of pm1008dcpCtrlprotocol Article |
| 1.3.6.1.4.1.20044.27.6.2.48.1 | Rowpm1008dcpCtrlprotocolEntry | not-accessible | current | Row definition for the pm1008dcpCtrlprotocol table |
| 1.3.6.1.4.1.20044.27.6.2.48.1.1 | Columnpm1008dcpCtrlprotocolIndex | read-only | current | Index definition for the pm1008dcpCtrlprotocol table |
| 1.3.6.1.4.1.20044.27.6.2.48.1.2 | Columnpm1008dcpCtrlprotocolPortn | read-write | current | Protocol used for client port: This OID sets the protocol of the Client port. |
| 1.3.6.1.4.1.20044.27.6.2.128 | Tablepm1008dcpCtrladddropTsClientARxProtectTable | not-accessible | current | List of pm1008dcpCtrladddropTsClientARxProtect Article |
| 1.3.6.1.4.1.20044.27.6.2.128.1 | Rowpm1008dcpCtrladddropTsClientARxProtectEntry | not-accessible | current | Row definition for the pm1008dcpCtrladddropTsClientARxProtect table |
| 1.3.6.1.4.1.20044.27.6.2.128.1.1 | Columnpm1008dcpCtrladddropTsClientARxProtectIndex | read-only | current | Index definition for the pm1008dcpCtrladddropTsClientARxProtect table |
| 1.3.6.1.4.1.20044.27.6.2.128.1.2 | Columnpm1008dcpCtrladddropTsClientARxProtectPortn | read-write | current | Client A Switch Mode :This bit selects the manual (1) or automatic (0) switch method <Help> This control defines the protection switch mode on the client inter… |
| 1.3.6.1.4.1.20044.27.6.2.136 | Tablepm1008dcpCtrladddropTsPairModeTable | not-accessible | current | List of pm1008dcpCtrladddropTsPairMode Article |
| 1.3.6.1.4.1.20044.27.6.2.136.1 | Rowpm1008dcpCtrladddropTsPairModeEntry | not-accessible | current | Row definition for the pm1008dcpCtrladddropTsPairMode table |
| 1.3.6.1.4.1.20044.27.6.2.136.1.1 | Columnpm1008dcpCtrladddropTsPairModeIndex | read-only | current | Index definition for the pm1008dcpCtrladddropTsPairMode table |
| 1.3.6.1.4.1.20044.27.6.2.136.1.2 | Columnpm1008dcpCtrladddropTsPairModePortn | read-write | current | TS Group Mode :This OID selects the mode on the group of clients <Help> This control defines the mode (Add/Drop or Split&Select) of two consecutive Client (1/2… |
| 1.3.6.1.4.1.20044.27.6.3 | Nodepm1008dcpCtrlLine | |||
| 1.3.6.1.4.1.20044.27.6.3.64 | Nodepm1008dcpCtrlcommAccessLoop | |||
| 1.3.6.1.4.1.20044.27.6.3.64.1 | Scalarpm1008dcpCtrlCommAccessloop | read-write | deprecated | PM Full Access Loop Mode :This OID, when set, puts the module in common access loop back, looping the 10 Gb/s output signal on the 10 Gb/s input. |
| 1.3.6.1.4.1.20044.27.6.3.66 | Nodepm1008dcpCtrllineLoop | |||
| 1.3.6.1.4.1.20044.27.6.3.66.1 | Scalarpm1008dcpCtrlLineLoop | read-write | deprecated | PM Line Loop Mode :This OID, when set at '1' puts the module in line loopback mode, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. The Ups… |
| 1.3.6.1.4.1.20044.27.6.3.67 | Nodepm1008dcpCtrlmsAis | |||
| 1.3.6.1.4.1.20044.27.6.3.67.1 | Scalarpm1008dcpCtrlMsAis | read-write | current | Insert MS-AIS/L-AIS On Line Output :This OID, when set, inserts an MS-AIS/L-AIS in the outgoing STM-64/OC-192 signal. |
| 1.3.6.1.4.1.20044.27.6.3.69 | Tablepm1008dcpCtrlfecDisableTable | not-accessible | current | List of pm1008dcpCtrlfecDisable Article |
| 1.3.6.1.4.1.20044.27.6.3.69.1 | Rowpm1008dcpCtrlfecDisableEntry | not-accessible | current | Row definition for the pm1008dcpCtrlfecDisable table |
| 1.3.6.1.4.1.20044.27.6.3.69.1.1 | Columnpm1008dcpCtrlfecDisableIndex | read-only | current | Index definition for the pm1008dcpCtrlfecDisable table |
| 1.3.6.1.4.1.20044.27.6.3.69.1.2 | Columnpm1008dcpCtrlfecDisablePortn | read-write | current | Forward Error Correction Inhibition :This OID, when set, inhibits the Forward Error Correction feature on the line input <Help> This control enables/disables t… |
| 1.3.6.1.4.1.20044.27.6.3.74 | Tablepm1008dcpCtrllineOosModeTable | not-accessible | current | List of pm1008dcpCtrllineOosMode Article |
| 1.3.6.1.4.1.20044.27.6.3.74.1 | Rowpm1008dcpCtrllineOosModeEntry | not-accessible | current | Row definition for the pm1008dcpCtrllineOosMode table |
| 1.3.6.1.4.1.20044.27.6.3.74.1.1 | Columnpm1008dcpCtrllineOosModeIndex | read-only | current | Index definition for the pm1008dcpCtrllineOosMode table |
| 1.3.6.1.4.1.20044.27.6.3.74.1.2 | Columnpm1008dcpCtrllineOosModePortn | read-write | current | Line Port Out Of Service :This OID sets the line port Out Of Service <Help> This control defines the service state of the line port |
| 1.3.6.1.4.1.20044.27.6.3.208 | Tablepm1008dcpCtrlxfpOnoffTable | not-accessible | current | List of pm1008dcpCtrlxfpOnoff Article |
| 1.3.6.1.4.1.20044.27.6.3.208.1 | Rowpm1008dcpCtrlxfpOnoffEntry | not-accessible | current | Row definition for the pm1008dcpCtrlxfpOnoff table |
| 1.3.6.1.4.1.20044.27.6.3.208.1.1 | Columnpm1008dcpCtrlxfpOnoffIndex | read-only | current | Index definition for the pm1008dcpCtrlxfpOnoff table |
| 1.3.6.1.4.1.20044.27.6.3.208.1.2 | Columnpm1008dcpCtrlxfpOnoffPortn | read-write | current | Line Optical Laser Shutdown :This OID switches off the XFP or the OTX <Help> This control defines the laser state of the line transceiver |
| 1.3.6.1.4.1.20044.27.6.3.209 | Tablepm1008dcpCtrlxfpLineLoopTable | not-accessible | current | List of pm1008dcpCtrlxfpLineLoop Article |
| 1.3.6.1.4.1.20044.27.6.3.209.1 | Rowpm1008dcpCtrlxfpLineLoopEntry | not-accessible | current | Row definition for the pm1008dcpCtrlxfpLineLoop table |
| 1.3.6.1.4.1.20044.27.6.3.209.1.1 | Columnpm1008dcpCtrlxfpLineLoopIndex | read-only | current | Index definition for the pm1008dcpCtrlxfpLineLoop table |
| 1.3.6.1.4.1.20044.27.6.3.209.1.2 | Columnpm1008dcpCtrlxfpLineLoopPortn | read-write | current | Line XFP/OTX Loop :This OID operates a line loopback on the XFP or the OTX <Help> This control defines the line loop back of the line transceiver |
| 1.3.6.1.4.1.20044.27.6.3.210 | Tablepm1008dcpCtrlxfpXfiLoopTable | not-accessible | current | List of pm1008dcpCtrlxfpXfiLoop Article |
| 1.3.6.1.4.1.20044.27.6.3.210.1 | Rowpm1008dcpCtrlxfpXfiLoopEntry | not-accessible | current | Row definition for the pm1008dcpCtrlxfpXfiLoop table |
| 1.3.6.1.4.1.20044.27.6.3.210.1.1 | Columnpm1008dcpCtrlxfpXfiLoopIndex | read-only | current | Index definition for the pm1008dcpCtrlxfpXfiLoop table |
| 1.3.6.1.4.1.20044.27.6.3.210.1.2 | Columnpm1008dcpCtrlxfpXfiLoopPortn | read-write | current | Line XFP/OTX XFI Loop :This OID operates a XFI loopback on the XFP or the OTX <Help> This control defines the XFI loop back of the line transceiver |
| 1.3.6.1.4.1.20044.27.6.3.212 | Tablepm1008dcpCtrllineTunableChannelTable | not-accessible | current | List of pm1008dcpCtrllineTunableChannel Article |
| 1.3.6.1.4.1.20044.27.6.3.212.1 | Rowpm1008dcpCtrllineTunableChannelEntry | not-accessible | current | Row definition for the pm1008dcpCtrllineTunableChannel table |
| 1.3.6.1.4.1.20044.27.6.3.212.1.1 | Columnpm1008dcpCtrllineTunableChannelIndex | read-only | current | Index definition for the pm1008dcpCtrllineTunableChannel table |
| 1.3.6.1.4.1.20044.27.6.3.212.1.2 | Columnpm1008dcpCtrllineTunableChannelPortn | read-write | current | ITU Channel :This OID selects the ITU channel of the Line OTX TLH Laser <Help> This control defines the ITU channel of the Line OTX TLH Laser |
| 1.3.6.1.4.1.20044.27.6.3.213 | Tablepm1008dcpCtrllinePhotodiodeModeTable | not-accessible | current | List of pm1008dcpCtrllinePhotodiodeMode Article |
| 1.3.6.1.4.1.20044.27.6.3.213.1 | Rowpm1008dcpCtrllinePhotodiodeModeEntry | not-accessible | current | Row definition for the pm1008dcpCtrllinePhotodiodeMode table |
| 1.3.6.1.4.1.20044.27.6.3.213.1.1 | Columnpm1008dcpCtrllinePhotodiodeModeIndex | read-only | current | Index definition for the pm1008dcpCtrllinePhotodiodeMode table |
| 1.3.6.1.4.1.20044.27.6.3.213.1.2 | Columnpm1008dcpCtrllinePhotodiodeModePortn | read-write | current | OTX TLH Rx Sens. Mode :This OID defines the Rx sensiblity mode of the Line OTX TLH <Help> This control defines the receiver sensibility mode of the Line OTX TL… |
| 1.3.6.1.4.1.20044.27.6.3.214 | Tablepm1008dcpCtrllinePhotodiodeValueTable | not-accessible | current | List of pm1008dcpCtrllinePhotodiodeValue Article |
| 1.3.6.1.4.1.20044.27.6.3.214.1 | Rowpm1008dcpCtrllinePhotodiodeValueEntry | not-accessible | current | Row definition for the pm1008dcpCtrllinePhotodiodeValue table |
| 1.3.6.1.4.1.20044.27.6.3.214.1.1 | Columnpm1008dcpCtrllinePhotodiodeValueIndex | read-only | current | Index definition for the pm1008dcpCtrllinePhotodiodeValue table |
| 1.3.6.1.4.1.20044.27.6.3.214.1.2 | Columnpm1008dcpCtrllinePhotodiodeValuePortn | read-write | current | OTX TLH Rx Sensibility :This OID sets the Rx sensibility of the Line OTX TLH (custom mode only) <Help> This control defines the receiver sensibility value (onl… |
| 1.3.6.1.4.1.20044.27.6.3.215 | Tablepm1008dcpCtrllinePowerLaserTable | not-accessible | current | List of pm1008dcpCtrllinePowerLaser Article |
| 1.3.6.1.4.1.20044.27.6.3.215.1 | Rowpm1008dcpCtrllinePowerLaserEntry | not-accessible | current | Row definition for the pm1008dcpCtrllinePowerLaser table |
| 1.3.6.1.4.1.20044.27.6.3.215.1.1 | Columnpm1008dcpCtrllinePowerLaserIndex | read-only | current | Index definition for the pm1008dcpCtrllinePowerLaser table |
| 1.3.6.1.4.1.20044.27.6.3.215.1.2 | Columnpm1008dcpCtrllinePowerLaserPortn | read-write | current | Line Laser Output Power [3-5] :This OID sets the output power value on the laser of the Line OTX TLH (AV=Power*10+158) (Unit = dBm) <Help> This control defines… |
| 1.3.6.1.4.1.20044.27.6.3.216 | Tablepm1008dcpCtrlotxVlhResetTable | not-accessible | current | List of pm1008dcpCtrlotxVlhReset Article |
| 1.3.6.1.4.1.20044.27.6.3.216.1 | Rowpm1008dcpCtrlotxVlhResetEntry | not-accessible | current | Row definition for the pm1008dcpCtrlotxVlhReset table |
| 1.3.6.1.4.1.20044.27.6.3.216.1.1 | Columnpm1008dcpCtrlotxVlhResetIndex | read-only | current | Index definition for the pm1008dcpCtrlotxVlhReset table |
| 1.3.6.1.4.1.20044.27.6.3.216.1.2 | Columnpm1008dcpCtrlOtxVlhResetPortn | read-write | current | OTX-VLH Reset :This OID resets the OTX-VLH module <Help> This control resets the OTX-VLH and its parameters |
| 1.3.6.1.4.1.20044.27.6.3.217 | Tablepm1008dcpCtrllineAccessLoopTable | not-accessible | current | List of pm1008dcpCtrllineAccessLoop Article |
| 1.3.6.1.4.1.20044.27.6.3.217.1 | Rowpm1008dcpCtrllineAccessLoopEntry | not-accessible | current | Row definition for the pm1008dcpCtrllineAccessLoop table |
| 1.3.6.1.4.1.20044.27.6.3.217.1.1 | Columnpm1008dcpCtrllineAccessLoopIndex | read-only | current | Index definition for the pm1008dcpCtrllineAccessLoop table |
| 1.3.6.1.4.1.20044.27.6.3.217.1.2 | Columnpm1008dcpCtrllineAccessLoopPortn | read-write | current | Line Facility Loopback :This OID operates a Line Facility Loopback, looping line input signal on the line output port. The loop is located on the line transcei… |
| 1.3.6.1.4.1.20044.27.6.3.218 | Tablepm1008dcpCtrllineLoopTransceiverTable | not-accessible | current | List of pm1008dcpCtrllineLoopTransceiver Article |
| 1.3.6.1.4.1.20044.27.6.3.218.1 | Rowpm1008dcpCtrllineLoopTransceiverEntry | not-accessible | current | Row definition for the pm1008dcpCtrllineLoopTransceiver table |
| 1.3.6.1.4.1.20044.27.6.3.218.1.1 | Columnpm1008dcpCtrllineLoopTransceiverIndex | read-only | current | Index definition for the pm1008dcpCtrllineLoopTransceiver table |
| 1.3.6.1.4.1.20044.27.6.3.218.1.2 | Columnpm1008dcpCtrllineLoopTransceiverPortn | read-write | current | Line Terminal Loopback :This OID operates a Line Terminal Loopback, looping line input signal on the line output port. The loop is located on all client transc… |
| 1.3.6.1.4.1.20044.27.7 | Nodepm1008dcpri | |||
| 1.3.6.1.4.1.20044.27.7.1 | Nodepm1008dcpriTable | |||
| 1.3.6.1.4.1.20044.27.7.1.1 | Tablepm1008dcpRinvSfpTable | not-accessible | current | List of the SFPs on the selected module |
| 1.3.6.1.4.1.20044.27.7.1.1.1 | Rowpm1008dcpRinvSfpEntry | not-accessible | current | Row definition for the SFP table |
| 1.3.6.1.4.1.20044.27.7.1.1.1.1 | Columnpm1008dcpRinvSfpIndex | read-only | current | Index for SFP table |
| 1.3.6.1.4.1.20044.27.7.1.1.1.2 | Columnpm1008dcpRinvsfp | read-only | current | Inventory for the SFP: This OID contains the inventory for the SFP |
| 1.3.6.1.4.1.20044.27.7.1.2 | Tablepm1008dcpRinvLineTable | not-accessible | current | List of the XFPs on the selected module |
| 1.3.6.1.4.1.20044.27.7.1.2.1 | Rowpm1008dcpRinvLineEntry | not-accessible | current | Row definition for the XFP table |
| 1.3.6.1.4.1.20044.27.7.1.2.1.1 | Columnpm1008dcpRinvLineIndex | read-only | current | Index for XFP table |
| 1.3.6.1.4.1.20044.27.7.1.2.1.2 | Columnpm1008dcpRinvxfpLine | read-only | current | Inventory for the XFP: This OID contains the inventory for the XFP |
| 1.3.6.1.4.1.20044.27.7.2 | Scalarpm1008dcpRinvReloadInventory | read-write | current | Reload the inventory: This OID triggers an inventory reload. |
| 1.3.6.1.4.1.20044.27.7.3 | Scalarpm1008dcpRinvHwPlatform | read-only | current | HW platform description: This OID contains the description of the Hardware platform. |
| 1.3.6.1.4.1.20044.27.7.4 | Scalarpm1008dcpRinvModulePlatform | read-only | current | Module platform description: This OID contains the description of the Module. |
| 1.3.6.1.4.1.20044.27.7.5 | Scalarpm1008dcpRinvSwPlatform | read-only | current | SW platform description: This OID contains the description of the Software platform. |
| 1.3.6.1.4.1.20044.27.7.6 | Scalarpm1008dcpRinvGwPlatform | read-only | current | GW platform desciption: This OID contains the description of the Gateware platform. |
| 1.3.6.1.4.1.20044.27.8 | Nodepm1008dcpdownload | |||
| 1.3.6.1.4.1.20044.27.8.1 | Nodepm1008dcpDwlOther | |||
| 1.3.6.1.4.1.20044.27.8.1.0 | Nodepm1008dcpDwlrestartProcess | |||
| 1.3.6.1.4.1.20044.27.8.1.0.1 | Scalarpm1008dcpDwlWarmRestartProcessed | read-only | current | Warm Restart :This OID indicates that the module last restart was a Warm RESTART |
| 1.3.6.1.4.1.20044.27.8.1.0.2 | Scalarpm1008dcpDwlColdRestartProcessed | read-only | current | Cold Restart :This OID indicates that the module last restart was a Cold RESTART |
| 1.3.6.1.4.1.20044.27.8.1.1 | Nodepm1008dcpDwlswBanksUsed | |||
| 1.3.6.1.4.1.20044.27.8.1.1.1 | Scalarpm1008dcpDwlSwBank1Used | read-only | current | SW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.27.8.1.1.2 | Scalarpm1008dcpDwlSwBank2Used | read-only | current | SW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby |
| 1.3.6.1.4.1.20044.27.8.1.1.5 | Scalarpm1008dcpDwlSwBank1Notempty | read-only | current | SW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package |
| 1.3.6.1.4.1.20044.27.8.1.1.6 | Scalarpm1008dcpDwlSwBank2Notempty | read-only | current | SW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package |
| 1.3.6.1.4.1.20044.27.8.1.2 | Nodepm1008dcpDwlgwBanksUsed | |||
| 1.3.6.1.4.1.20044.27.8.1.2.1 | Scalarpm1008dcpDwlGwBank1Used | read-only | current | GW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.27.8.1.2.2 | Scalarpm1008dcpDwlGwBank2Used | read-only | current | GW bank 2 active :This OID indicates the module is working on GW bank 2 |
| 1.3.6.1.4.1.20044.27.8.1.2.3 | Scalarpm1008dcpDwlGwBank3Used | read-only | current | GW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby |
| 1.3.6.1.4.1.20044.27.8.1.2.4 | Scalarpm1008dcpDwlGwBank4Used | read-only | current | GW bank 4 active :This OID indicates the module is working on GW bank 4 |
| 1.3.6.1.4.1.20044.27.8.1.2.5 | Scalarpm1008dcpDwlGwBank1Notempty | read-only | current | GW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package |
| 1.3.6.1.4.1.20044.27.8.1.2.6 | Scalarpm1008dcpDwlGwBank2Notempty | read-only | current | GW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2 |
| 1.3.6.1.4.1.20044.27.8.1.2.7 | Scalarpm1008dcpDwlGwBank3Notempty | read-only | current | GW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package |
| 1.3.6.1.4.1.20044.27.8.1.2.8 | Scalarpm1008dcpDwlGwBank4Notempty | read-only | current | GW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4 |
| 1.3.6.1.4.1.20044.27.8.2 | Nodepm1008dcpDwlClient | |||
| 1.3.6.1.4.1.20044.27.8.3 | Nodepm1008dcpDwlLine | |||
| 1.3.6.1.4.1.20044.27.9 | Nodepm1008dcpConfig | |||
| 1.3.6.1.4.1.20044.27.9.1 | Nodepm1008dcpCfgAccessCAisCsf | |||
| 1.3.6.1.4.1.20044.27.9.1.1 | Tablepm1008dcpCfgClientcaiscsfTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.27.9.1.1.1 | Rowpm1008dcpCfgClientcaiscsfEntry | not-accessible | current | Row definition for the accessCAisCsf table |
| 1.3.6.1.4.1.20044.27.9.1.1.1.1 | Columnpm1008dcpCfgClientcaiscsfIndex | read-only | current | Index definition for the clientcaiscsf table |
| 1.3.6.1.4.1.20044.27.9.1.1.1.3 | Columnpm1008dcpCfgCAisModePortn | read-write | current | CAIS mode on Client Port :This register enables/disables port laser shutdown on CAIS insertion condition |
| 1.3.6.1.4.1.20044.27.9.1.1.1.9 | Columnpm1008dcpCfgUpAccessioAlmPortn | read-write | current | CSF contributors on Client Port :This register configures the contributors to upstream CSF insertion on the port. |
| 1.3.6.1.4.1.20044.27.9.1.1.1.10 | Columnpm1008dcpCfgUpMapperDeAlmPortn | read-write | current | CSF contributors on Client Port :This register configures the contributors to upstream CSF insertion on the port. |
| 1.3.6.1.4.1.20044.27.9.1.1.1.17 | Columnpm1008dcpCfgDownAccessioAlmPortn | read-write | current | CAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port. |
| 1.3.6.1.4.1.20044.27.9.1.1.1.18 | Columnpm1008dcpCfgDownMapperDeAlmPortn | read-write | current | CAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port. |
| 1.3.6.1.4.1.20044.27.9.1.1.1.19 | Columnpm1008dcpCfgDownDfrmAlmPortn | read-write | current | CAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port. |
| 1.3.6.1.4.1.20044.27.9.1.1.1.20 | Columnpm1008dcpCfgDownLineSyncAlarmsPortn | read-write | deprecated | CAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port. |
| 1.3.6.1.4.1.20044.27.9.2 | Nodepm1008dcpCfgStartup | |||
| 1.3.6.1.4.1.20044.27.9.2.1 | Tablepm1008dcpCfgClientStartupTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.27.9.2.1.1 | Rowpm1008dcpCfgClientStartupEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.27.9.2.1.1.1 | Columnpm1008dcpCfgClientStartupIndex | read-only | current | Index definition for the clientStartup table |
| 1.3.6.1.4.1.20044.27.9.2.1.1.3 | Columnpm1008dcpCfgSystConfPortPortn | read-write | current | Default Settings on Client Port :This register configures the default initialisation settings on the port. |
| 1.3.6.1.4.1.20044.27.9.2.1.1.4 | Columnpm1008dcpCfgNetConfPortPortn | read-write | current | Default Protocol on Client Port :This register configures the default initialisation protocol on the port. |
| 1.3.6.1.4.1.20044.27.9.2.1.1.5 | Columnpm1008dcpCfgAdddropConfPortPortn | read-write | deprecated | Default Add&Drop mode on Client Port :This register configures the default Add&Drop mode on the port. |
| 1.3.6.1.4.1.20044.27.9.2.2 | Nodepm1008dcptablelineStartup | |||
| 1.3.6.1.4.1.20044.27.9.2.2.2 | Scalarpm1008dcpCfgsystConfLine1 | read-write | current | Default Settings on Line 1 :This register configures the default initialisation settings on Line port 1. |
| 1.3.6.1.4.1.20044.27.9.2.2.5 | Scalarpm1008dcpCfglineOptions1 | read-write | current | Default Options on Active Line Port :This register configures the default options on the active line port |
| 1.3.6.1.4.1.20044.27.9.2.2.6 | Scalarpm1008dcpCfgsystConfLine2 | read-write | current | Default Settings on Line 2 :This register configures the default initialisation settings on Line port 2. |
| 1.3.6.1.4.1.20044.27.9.2.2.7 | Scalarpm1008dcpCfglineSelection | read-write | current | Default Settings of active line :This register configures the start up active line. |
| 1.3.6.1.4.1.20044.27.9.2.2.9 | Scalarpm1008dcpCfglineOptions2 | read-write | deprecated | Default Options on Active Line Port :This register configures the default options on the active line port |
| 1.3.6.1.4.1.20044.27.9.2.3 | Tablepm1008dcpCfgXfpTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.27.9.2.3.1 | Rowpm1008dcpCfgXfpEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.27.9.2.3.1.1 | Columnpm1008dcpCfgXfpIndex | read-only | current | Index definition for the xfp table |
| 1.3.6.1.4.1.20044.27.9.2.3.1.3 | Columnpm1008dcpCfgSystConfXfpPortn | read-write | current | Default settings on XFP Port :This register configures the default initialisation settings on XFP port. |
| 1.3.6.1.4.1.20044.27.9.2.3.1.4 | Columnpm1008dcpCfgDataRateConfXfpPortn | read-write | deprecated | : |
| 1.3.6.1.4.1.20044.27.9.2.4 | Tablepm1008dcpCfgOtxtlhTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.27.9.2.4.1 | Rowpm1008dcpCfgOtxtlhEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.27.9.2.4.1.1 | Columnpm1008dcpCfgOtxtlhIndex | read-only | current | Index definition for the otxtlh table |
| 1.3.6.1.4.1.20044.27.9.2.4.1.3 | Columnpm1008dcpCfgNuPortn | read-write | deprecated | : |
| 1.3.6.1.4.1.20044.27.9.2.4.1.4 | Columnpm1008dcpCfgLineDitherRatePortn | read-write | current | Default Line OTX TLH FM amplitude :This register configures the start-up width of the frequency modulation of the Line OTX TLH |
| 1.3.6.1.4.1.20044.27.9.2.4.1.5 | Columnpm1008dcpCfgLineDitherFhzPortn | read-write | current | Default Line OTX TLH FM frequency :This register configures the start-up frequency of the frequency modulation of the Line OTX TLH |
| 1.3.6.1.4.1.20044.27.9.2.4.1.6 | Columnpm1008dcpCfgLinePwrLaserPortn | read-write | current | Defaut Line OTX TLH output Power :This register configures the start-up output power of the Line OTX TLH (Unit = dBm) |
| 1.3.6.1.4.1.20044.27.9.2.4.1.7 | Columnpm1008dcpCfgLineFCurrentPortn | read-write | current | Default Line OTX TLH Channel :This register configures the start-up laser channel of the Line OTX TLH |
| 1.3.6.1.4.1.20044.27.9.2.4.1.8 | Columnpm1008dcpCfgLineGridCurrentPortn | read-write | current | Default Line OTX TLH Grid :This register configures the start-up laser grid of the Line OTX TLH |
| 1.3.6.1.4.1.20044.27.9.2.4.1.9 | Columnpm1008dcpCfgFPortn | read-write | current | Default Line OTX TLH lowest Freq :This register configures the start-up lowest frequency supported on the Line OTX TLH |
| 1.3.6.1.4.1.20044.27.9.2.4.1.10 | Columnpm1008dcpCfgReservedPortn | read-write | deprecated | : |
| 1.3.6.1.4.1.20044.27.9.2.4.1.11 | Columnpm1008dcpCfgLinePhotodiodeModePortn | read-write | current | Default Line OTX TLH APD mode :This register configures the start-up APD mode of the Line OTX TLH |
| 1.3.6.1.4.1.20044.27.9.2.4.1.12 | Columnpm1008dcpCfgLinePhotodiodeValuePortn | read-write | current | Default Line OTX TLH APD atten. :This register configures the start-up APD attenuation on the Line OTX TLH |
| 1.3.6.1.4.1.20044.27.9.3 | Nodepm1008dcpCfgOther | |||
| 1.3.6.1.4.1.20044.27.9.3.1 | Nodepm1008dcptablemoduleOther | |||
| 1.3.6.1.4.1.20044.27.9.3.1.2 | Scalarpm1008dcpCfgmode | read-write | current | Default settings on Module :This register selects the DCC configuration of the PM |
| 1.3.6.1.4.1.20044.27.9.3.1.3 | Scalarpm1008dcpCfgadddropTsPairMode1 | read-write | current | Default settings on TS Group Mode :This register selects selects the mode on the group of clients |
| 1.3.6.1.4.1.20044.27.9.3.1.4 | Scalarpm1008dcpCfgadddropTsPairMode2 | read-write | current | Default settings on TS Group Mode :This register selects selects the mode on the group of clients |
| 1.3.6.1.4.1.20044.27.9.3.1.5 | Scalarpm1008dcpCfgadddropTsPairMode3 | read-write | current | Default settings on TS Group Mode :This register selects selects the mode on the group of clients |
| 1.3.6.1.4.1.20044.27.9.3.1.6 | Scalarpm1008dcpCfgadddropTsPairMode4 | read-write | current | Default settings on TS Group Mode :This register selects selects the mode on the group of clients |
| 1.3.6.1.4.1.20044.27.9.4 | Nodepm1008dcpCfgLabels | |||
| 1.3.6.1.4.1.20044.27.9.4.1 | Tablepm1008dcpCfgLabelclientTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.27.9.4.1.1 | Rowpm1008dcpCfgLabelclientEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.27.9.4.1.1.1 | Columnpm1008dcpCfgLabelclientIndex | read-only | current | Index definition for the labelclient table |
| 1.3.6.1.4.1.20044.27.9.4.1.1.3 | Columnpm1008dcpCfgLabelclientPortn | read-write | current | Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. |
| 1.3.6.1.4.1.20044.27.9.4.2 | Tablepm1008dcpCfgLabellineTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.27.9.4.2.1 | Rowpm1008dcpCfgLabellineEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.27.9.4.2.1.1 | Columnpm1008dcpCfgLabellineIndex | read-only | current | Index definition for the labelline table |
| 1.3.6.1.4.1.20044.27.9.4.2.1.3 | Columnpm1008dcpCfgLabellinePortn | read-write | current | Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. |
| 1.3.6.1.4.1.20044.27.9.5 | Nodepm1008dcpCfgStartuptablefive | |||
| 1.3.6.1.4.1.20044.27.9.5.1 | Tablepm1008dcpCfgOtxtlhcapabilitiesTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.27.9.5.1.1 | Rowpm1008dcpCfgOtxtlhcapabilitiesEntry | not-accessible | current | Row definition for the startuptablefive table |
| 1.3.6.1.4.1.20044.27.9.5.1.1.1 | Columnpm1008dcpCfgOtxtlhcapabilitiesIndex | read-only | current | Index definition for the otxtlhcapabilities table |
| 1.3.6.1.4.1.20044.27.9.5.1.1.3 | Columnpm1008dcpCfgComponentTypePortn | read-only | current | Component parameters :This OID defines the component parameters |
| 1.3.6.1.4.1.20044.27.9.5.1.1.4 | Columnpm1008dcpCfgMiscellaneousPortn | read-only | current | Miscellaneous default settings :This OID defines the miscellaneous parameters |
| 1.3.6.1.4.1.20044.27.9.5.1.1.5 | Columnpm1008dcpCfgFirstChannelPortn | read-only | current | Number of the first channel of the component :This OID defines the first channel number of the PM |
| 1.3.6.1.4.1.20044.27.9.5.1.1.6 | Columnpm1008dcpCfgLastChannelPortn | read-only | current | Number of the last channel of the component :This OID defines the last channel number of the PM |
| 1.3.6.1.4.1.20044.27.9.5.1.1.7 | Columnpm1008dcpCfgGridPortn | read-only | current | Grid value of the component :This OID defines the grid of the PM |
| 1.3.6.1.4.1.20044.27.9.257 | Scalarpm1008dcpCfgWriteConfiguration | read-write | current | Write configuration to module:This OID writes the complete configuration to the module |
| 1.3.6.1.4.1.20044.27.10 | Nodepm1008dcptraps | |||
| 1.3.6.1.4.1.20044.27.10.2 | Scalarpm1008dcptrapPortNumber | read-only | current | Last port which generates a trap |
| 1.3.6.1.4.1.20044.27.10.3 | Scalarpm1008dcptrapLineNumber | read-only | current | Last Line which generates a trap |
| 1.3.6.1.4.1.20044.27.10.4 | Scalarpm1008dcptrapBoardNumber | read-only | current | Last module which generates a trap |
| 1.3.6.1.4.1.20044.27.10.30 | Notificationpm1008dcpLineTrapNotUrgentGoesOn | current | Not urgent Line default is activated | |
| 1.3.6.1.4.1.20044.27.10.31 | Notificationpm1008dcpLineTrapNotUrgentGoesOff | current | Not urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.27.10.32 | Notificationpm1008dcpLineTrapUrgentGoesOn | current | Urgent Line default is activated | |
| 1.3.6.1.4.1.20044.27.10.33 | Notificationpm1008dcpLineTrapUrgentGoesOff | current | Urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.27.10.34 | Notificationpm1008dcpLineTrapCritGoesOn | current | Critical Line default is activated | |
| 1.3.6.1.4.1.20044.27.10.35 | Notificationpm1008dcpLineTrapCritGoesOff | current | Critical Line default disappeared | |
| 1.3.6.1.4.1.20044.27.10.40 | Notificationpm1008dcpClientTrapNotUrgentGoesOn | current | Not urgent client default is activated | |
| 1.3.6.1.4.1.20044.27.10.41 | Notificationpm1008dcpClientTrapNotUrgentGoesOff | current | Not urgent client default disappeared | |
| 1.3.6.1.4.1.20044.27.10.42 | Notificationpm1008dcpClientTrapUrgentGoesOn | current | Urgent client default is activated | |
| 1.3.6.1.4.1.20044.27.10.43 | Notificationpm1008dcpClientTrapUrgentGoesOff | current | Urgent client default disappeared | |
| 1.3.6.1.4.1.20044.27.10.44 | Notificationpm1008dcpClientTrapCritGoesOn | current | Critical client default is activated | |
| 1.3.6.1.4.1.20044.27.10.45 | Notificationpm1008dcpClientTrapCritGoesOff | current | Critical client default disappeared | |
| 1.3.6.1.4.1.20044.27.10.50 | Notificationpm1008dcpPowerTrapUrgentGoesOn | current | Urgent power supply default is activated | |
| 1.3.6.1.4.1.20044.27.10.51 | Notificationpm1008dcpPowerTrapUrgentGoesOff | current | Urgent power supply default disappeared | |
| 1.3.6.1.4.1.20044.27.11 | Nodepm1008dcpMonitoring | |||
| 1.3.6.1.4.1.20044.27.11.1 | Nodepm1008dcpMonOther | |||
| 1.3.6.1.4.1.20044.27.11.1.3 | Nodepm1008dcpMonRmon | |||
| 1.3.6.1.4.1.20044.27.11.1.3.359 | Scalarpm1008dcpMonCountersReset | read-write | current | RMON Counters Reset:This OID resets and restarts all the RMON counters |
| 1.3.6.1.4.1.20044.27.11.1.3.360 | Scalarpm1008dcpMonCountersStop | read-write | current | RMON Counters stop:This OID stops all the RMON counters |
| 1.3.6.1.4.1.20044.27.11.2 | Nodepm1008dcpMonClient | |||
| 1.3.6.1.4.1.20044.27.11.2.4 | Nodepm1008dcpMonClientRmonCounter | |||
| 1.3.6.1.4.1.20044.27.11.2.4.16 | Tablepm1008dcpMonupRmonByteCntTable | not-accessible | current | List of pm1008dcpMonupRmonByteCnt Article |
| 1.3.6.1.4.1.20044.27.11.2.4.16.1 | Rowpm1008dcpMonupRmonByteCntEntry | not-accessible | current | Row definition for the pm1008dcpMonupRmonByteCnt table |
| 1.3.6.1.4.1.20044.27.11.2.4.16.1.1 | Columnpm1008dcpMonupRmonByteCntIndex | read-only | current | Index definition for the pm1008dcpMonupRmonByteCnt table |
| 1.3.6.1.4.1.20044.27.11.2.4.16.1.2 | Columnpm1008dcpMonupRmonByteCntValuePortn | read-only | current | Client Input Bytes :This counter is increased each time a data byte is received on the client port <Help> This counter gives the number of bytes received on th… |
| 1.3.6.1.4.1.20044.27.11.2.4.16.1.3 | Columnpm1008dcpMonupRmonByteCntErrorPortn | read-only | current | Bytes Counter Error :This OID when set indicates the Bytes counter value is invalid on clinet port |
| 1.3.6.1.4.1.20044.27.11.2.4.16.1.4 | Columnpm1008dcpMonupRmonByteCntOverloadPortn | read-only | current | Bytes Counter Overload :This OID when set indicates a Bytes counter overload on client port |
| 1.3.6.1.4.1.20044.27.11.2.4.24 | Tablepm1008dcpMonupRmonCrcErrorCntTable | not-accessible | current | List of pm1008dcpMonupRmonCrcErrorCnt Article |
| 1.3.6.1.4.1.20044.27.11.2.4.24.1 | Rowpm1008dcpMonupRmonCrcErrorCntEntry | not-accessible | current | Row definition for the pm1008dcpMonupRmonCrcErrorCnt table |
| 1.3.6.1.4.1.20044.27.11.2.4.24.1.1 | Columnpm1008dcpMonupRmonCrcErrorCntIndex | read-only | current | Index definition for the pm1008dcpMonupRmonCrcErrorCnt table |
| 1.3.6.1.4.1.20044.27.11.2.4.24.1.2 | Columnpm1008dcpMonupRmonCrcErrorCntValuePortn | read-only | current | Client Input CRC Errors :This counter is increased each time a CRC error is detected on the client port <Help> This counter gives the number of CRC Errors rece… |
| 1.3.6.1.4.1.20044.27.11.2.4.24.1.3 | Columnpm1008dcpMonupRmonCrcErrorCntErrorPortn | read-only | current | CRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on clinet port |
| 1.3.6.1.4.1.20044.27.11.2.4.24.1.4 | Columnpm1008dcpMonupRmonCrcErrorCntOverloadPortn | read-only | current | CRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on client port |
| 1.3.6.1.4.1.20044.27.11.2.4.32 | Tablepm1008dcpMonupRmonPacketsCntTable | not-accessible | current | List of pm1008dcpMonupRmonPacketsCnt Article |
| 1.3.6.1.4.1.20044.27.11.2.4.32.1 | Rowpm1008dcpMonupRmonPacketsCntEntry | not-accessible | current | Row definition for the pm1008dcpMonupRmonPacketsCnt table |
| 1.3.6.1.4.1.20044.27.11.2.4.32.1.1 | Columnpm1008dcpMonupRmonPacketsCntIndex | read-only | current | Index definition for the pm1008dcpMonupRmonPacketsCnt table |
| 1.3.6.1.4.1.20044.27.11.2.4.32.1.2 | Columnpm1008dcpMonupRmonPacketsCntValuePortn | read-only | current | Client Input Packets :This counter is increased each time a packet is received on the client port <Help> This counter gives the number of packets received on t… |
| 1.3.6.1.4.1.20044.27.11.2.4.32.1.3 | Columnpm1008dcpMonupRmonPacketsCntErrorPortn | read-only | current | Packets Counter Error :This OID when set indicates the Packets counter value is invalid on clinet port |
| 1.3.6.1.4.1.20044.27.11.2.4.32.1.4 | Columnpm1008dcpMonupRmonPacketsCntOverloadPortn | read-only | current | Packets Counter Overload :This OID when set indicates a Packets counter overload on client port |
| 1.3.6.1.4.1.20044.27.11.2.4.40 | Tablepm1008dcpMonupRmonBroadcastCntTable | not-accessible | current | List of pm1008dcpMonupRmonBroadcastCnt Article |
| 1.3.6.1.4.1.20044.27.11.2.4.40.1 | Rowpm1008dcpMonupRmonBroadcastCntEntry | not-accessible | current | Row definition for the pm1008dcpMonupRmonBroadcastCnt table |
| 1.3.6.1.4.1.20044.27.11.2.4.40.1.1 | Columnpm1008dcpMonupRmonBroadcastCntIndex | read-only | current | Index definition for the pm1008dcpMonupRmonBroadcastCnt table |
| 1.3.6.1.4.1.20044.27.11.2.4.40.1.2 | Columnpm1008dcpMonupRmonBroadcastCntValuePortn | read-only | current | Client Input Broadcast Packets :This counter is increased each time a broadcast packet is received on the client port <Help> This counter gives the number of B… |
| 1.3.6.1.4.1.20044.27.11.2.4.40.1.3 | Columnpm1008dcpMonupRmonBroadcastCntErrorPortn | read-only | current | Broadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on clinet port |
| 1.3.6.1.4.1.20044.27.11.2.4.40.1.4 | Columnpm1008dcpMonupRmonBroadcastCntOverloadPortn | read-only | current | Broadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port |
| 1.3.6.1.4.1.20044.27.11.2.4.48 | Tablepm1008dcpMonupRmonMulticastCntTable | not-accessible | current | List of pm1008dcpMonupRmonMulticastCnt Article |
| 1.3.6.1.4.1.20044.27.11.2.4.48.1 | Rowpm1008dcpMonupRmonMulticastCntEntry | not-accessible | current | Row definition for the pm1008dcpMonupRmonMulticastCnt table |
| 1.3.6.1.4.1.20044.27.11.2.4.48.1.1 | Columnpm1008dcpMonupRmonMulticastCntIndex | read-only | current | Index definition for the pm1008dcpMonupRmonMulticastCnt table |
| 1.3.6.1.4.1.20044.27.11.2.4.48.1.2 | Columnpm1008dcpMonupRmonMulticastCntValuePortn | read-only | current | Client Input Multicast Packets :This counter is increased each time a Multicast packet is received on the client port <Help> This counter gives the number of M… |
| 1.3.6.1.4.1.20044.27.11.2.4.48.1.3 | Columnpm1008dcpMonupRmonMulticastCntErrorPortn | read-only | current | Multicast Counter Error :This OID when set indicates the Multicast counter value is invalid on clinet port |
| 1.3.6.1.4.1.20044.27.11.2.4.48.1.4 | Columnpm1008dcpMonupRmonMulticastCntOverloadPortn | read-only | current | Multicast Counter Overload :This OID when set indicates a Multicast counter overload on client port |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| Pm1008dcpAdjustValue | INTEGER { otxadjustvalue0(0), otxadjustvalue1(1), otxadjustvalue2(2), otxadjustvalue3(3), otxadjustvalue4(4), otxadjustvalue5(5), otxadjustvalue6(6), otxadjustvalue7(7), otxadjustvalue8(8), otxadjustvalue9(9), otxadjustvalue10(10) } | current | Different values in Adjust mode on OTX-TLH on client and line ports |
| Pm1008dcpDccMode | INTEGER { dccNo(0), dcctermLine1(1), dcctermLine2(2), dcctermLines12(3), dccmaster(4), dccslaveLine12(7) } | current | Mode for DCC |
| Pm1008dcpModeAddDrop | INTEGER { dualPassThrough(1), addDropTsA(2), addDropTsB(4), splitSelectTsA(8), splitSelectTsB(16), splitSelectTsATsB(32) } | current | different mode for client B |
| Pm1008dcpModeAddDropA | INTEGER { passThroughA(1), addDropTsA(2), splitSelectTsA(4) } | current | different mode for client A |
| Pm1008dcpModeTimeSlot | INTEGER { dualPassThrough(1), addDropTsA(2), addDropTsB(4), splitSelectTsA(8), splitSelectTsB(16), splitSelectTsATsB(32) } | current | different mode for time slot |
| Pm1008dcpOtxChannel | INTEGER | current | Channel selection on OTX-TLH on client and line ports |
| Pm1008dcpOtxGrid | INTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50) } | current | Different grids on OTX-TLH on client and line ports |
| Pm1008dcpOtxMode | INTEGER { otx80mode(1), otx60mode(2), otxadjustmode(4) } | current | Different modes on OTX-TLH on client and line ports |
| Pm1008dcpProtectionStartUp | INTEGER { auto(2), manualX2Line2(0), manualX1Line1(1) } | current | protection for startup |
| Pm1008dcpProtectionTimeSlot | INTEGER { auto(0), manualX1Line1(257), manualX2Line2(513) } | current | protection for control |