MIB Viewer

EKINOPS-Pm100gemuxsfp-MIB

961 objects
Creation.
OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.107IdentitymodulePm100gemuxsfpCreation.
1.3.6.1.4.1.20044.107.2Nodepm100gemuxsfpalarms
1.3.6.1.4.1.20044.107.2.1Nodepm100gemuxsfpAlmOther
1.3.6.1.4.1.20044.107.2.1.1Nodepm100gemuxsfpAlmOtherNurg
1.3.6.1.4.1.20044.107.2.1.1.2Nodepm100gemuxsfpAlmsynthAlm2
1.3.6.1.4.1.20044.107.2.1.1.2.1Scalarpm100gemuxsfpAlmConfTableSaveread-onlycurrentPM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> infor…
1.3.6.1.4.1.20044.107.2.1.1.2.2Scalarpm100gemuxsfpAlmInvUploadread-onlycurrentInventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> informationalStatus(1000) <Alarmtype> ot…
1.3.6.1.4.1.20044.107.2.1.1.2.3Scalarpm100gemuxsfpAlmConfTableLoadread-onlycurrentPM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> informationalStat…
1.3.6.1.4.1.20044.107.2.1.1.2.4Scalarpm100gemuxsfpAlmCorrelatOffread-onlycurrentNot Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> informationalStatus(1000) <Alarmtype…
1.3.6.1.4.1.20044.107.2.1.1.2.5Scalarpm100gemuxsfpAlmMaintenanceOnread-onlycurrentMaintenance Mode :This OID indicates that the RM is in maintenance mode. <Help> This alarm indicates that the maintenance mode is enabled on the PM <Condtype> …
1.3.6.1.4.1.20044.107.2.1.2Nodepm100gemuxsfpAlmOtherUrg
1.3.6.1.4.1.20044.107.2.1.3Nodepm100gemuxsfpAlmOtherCrit
1.3.6.1.4.1.20044.107.2.1.3.0Nodepm100gemuxsfpAlmsynthAlm0
1.3.6.1.4.1.20044.107.2.1.3.0.2Scalarpm100gemuxsfpAlmFailFanread-onlycurrentFan Fail :This OID is at 1 when any fail occurs on the fan tray <Help> This alarm indicates that the Fan tray module is in a failure condition <Condtype> FAIL_…
1.3.6.1.4.1.20044.107.2.1.3.0.9Scalarpm100gemuxsfpAlmModGlobFailread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the RM <Help> This alarm is set on detection of a failure originating from the equip…
1.3.6.1.4.1.20044.107.2.1.3.0.15Scalarpm100gemuxsfpAlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.107.2.1.3.0.16Scalarpm100gemuxsfpAlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.107.2.2Nodepm100gemuxsfpAlmClient
1.3.6.1.4.1.20044.107.2.2.1Nodepm100gemuxsfpAlmClientNurg
1.3.6.1.4.1.20044.107.2.2.1.272Tablepm100gemuxsfpAlmclientSfpWarnDdmTablenot-accessiblecurrentList of pm100gemuxsfpAlmclientSfpWarnDdm Article
1.3.6.1.4.1.20044.107.2.2.1.272.1Rowpm100gemuxsfpAlmclientSfpWarnDdmEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpAlmclientSfpWarnDdm table
1.3.6.1.4.1.20044.107.2.2.1.272.1.1Columnpm100gemuxsfpAlmclientSfpWarnDdmIndexread-onlycurrentIndex definition for the pm100gemuxsfpAlmclientSfpWarnDdm table
1.3.6.1.4.1.20044.107.2.2.1.272.1.2Columnpm100gemuxsfpAlmTxPwLowWngPortnread-onlycurrentClient Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.107.2.2.1.272.1.3Columnpm100gemuxsfpAlmTxPwrHighWngPortnread-onlycurrentClient Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.107.2.2.1.272.1.4Columnpm100gemuxsfpAlmTxBiasLowWngPortnread-onlycurrentClient Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.107.2.2.1.272.1.5Columnpm100gemuxsfpAlmTxBiasHighWngPortnread-onlycurrentClient Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warn…
1.3.6.1.4.1.20044.107.2.2.1.272.1.6Columnpm100gemuxsfpAlmVccLowWngPortnread-onlycurrentClient Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Warn…
1.3.6.1.4.1.20044.107.2.2.1.272.1.7Columnpm100gemuxsfpAlmVccHighWngPortnread-onlycurrentClient Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Wa…
1.3.6.1.4.1.20044.107.2.2.1.272.1.8Columnpm100gemuxsfpAlmTempLowWngPortnread-onlycurrentClient Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indic…
1.3.6.1.4.1.20044.107.2.2.1.272.1.9Columnpm100gemuxsfpAlmTempHighWngPortnread-onlycurrentClient Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning ind…
1.3.6.1.4.1.20044.107.2.2.1.272.1.16Columnpm100gemuxsfpAlmRxPwrLowWngPortnread-onlycurrentClient Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning i…
1.3.6.1.4.1.20044.107.2.2.1.272.1.17Columnpm100gemuxsfpAlmRxPwrHighWngPortnread-onlycurrentClient Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning…
1.3.6.1.4.1.20044.107.2.2.2Nodepm100gemuxsfpAlmClientUrg
1.3.6.1.4.1.20044.107.2.2.2.152Tablepm100gemuxsfpAlmclientHostLaneFaultTablenot-accessiblecurrentList of pm100gemuxsfpAlmclientHostLaneFault Article
1.3.6.1.4.1.20044.107.2.2.2.152.1Rowpm100gemuxsfpAlmclientHostLaneFaultEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpAlmclientHostLaneFault table
1.3.6.1.4.1.20044.107.2.2.2.152.1.1Columnpm100gemuxsfpAlmclientHostLaneFaultIndexread-onlycurrentIndex definition for the pm100gemuxsfpAlmclientHostLaneFault table
1.3.6.1.4.1.20044.107.2.2.2.152.1.2Columnpm100gemuxsfpAlmClientLossOfSyncPortnread-onlycurrentClient Frame Alignment Loss :This OID indicates the module is not aligned with the incoming Client signal <Help> Alarm indicating the module is not aligned wit…
1.3.6.1.4.1.20044.107.2.2.2.152.1.3Columnpm100gemuxsfpAlmClientInputLossOfSigPortnread-onlycurrentClient Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Client Trscv <Help> Alarm indicating a Loss of Signal is detected on the Cl…
1.3.6.1.4.1.20044.107.2.2.2.152.1.4Columnpm100gemuxsfpAlmClientLanesMarkerUnlockPortnread-onlycurrentClient Lanes Marker Unlock :This OID indicates the Client lanes marker alignment is not lock <Help> Alarm indicating the Client lanes marker alignment is not l…
1.3.6.1.4.1.20044.107.2.2.2.152.1.5Columnpm100gemuxsfpAlmClientLanes6466UnlockPortnread-onlycurrentClient Lanes 64/66b Unlock :This OID indicates the Client 64/66b decoder is not lock <Help> Alarm indicating the Client 64/66b decoder is not lock <Condtype> C…
1.3.6.1.4.1.20044.107.2.2.2.152.1.6Columnpm100gemuxsfpAlmClientLanesNotAlignedPortnread-onlycurrentClient Lanes Not Aligned :This OID indicates the Client lanes are not aligned <Help> Alarm indicating the Client lanes are not aligned <Condtype> CLIENT_LANES_…
1.3.6.1.4.1.20044.107.2.2.2.152.1.7Columnpm100gemuxsfpAlmClientCsfDetectedPortnread-onlycurrentClient Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client…
1.3.6.1.4.1.20044.107.2.2.2.152.1.10Columnpm100gemuxsfpAlmClientTxHostLolPortnread-onlycurrentClient Host Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Client Trscv Host Lane <Help> Alarm indicating a Tx Loss of Lock on the Client Tr…
1.3.6.1.4.1.20044.107.2.2.2.152.1.11Columnpm100gemuxsfpAlmClientLaneTxFifoErrorPortnread-onlycurrentClient Host Lane Tx FIFO Error :This OID indicates a Tx FIFO Error on the Client Trscv Host Lane <Help> Alarm indicating a Tx FIFO Error on the Client Trscv Ho…
1.3.6.1.4.1.20044.107.2.2.2.152.1.15Columnpm100gemuxsfpAlmClientLinkStatusPortnread-onlycurrentClient Link Status :This OID indicates a Client linkup linkdown status <Help> This alarm indicates a Client linkup lindown status <Condtype> CLIENT_LINK_STATUS…
1.3.6.1.4.1.20044.107.2.2.2.152.1.16Columnpm100gemuxsfpAlmClientRxFaultPortnread-onlycurrentClient Rx Fault :This OID indicates a Client Rx fault on the receive path <Help> This alarm indicates a Client Rx fault on the receive path <Condtype> CLIENT_R…
1.3.6.1.4.1.20044.107.2.2.2.152.1.17Columnpm100gemuxsfpAlmClientTxFaultPortnread-onlycurrentClient Tx Fault :This OID indicates a Client Tx fault on the transmit path <Help> This alarm indicates a Client Tx fault on the transmit path <Condtype> CLIENT…
1.3.6.1.4.1.20044.107.2.2.2.240Tablepm100gemuxsfpAlmclientSfpAlmDdmTablenot-accessiblecurrentList of pm100gemuxsfpAlmclientSfpAlmDdm Article
1.3.6.1.4.1.20044.107.2.2.2.240.1Rowpm100gemuxsfpAlmclientSfpAlmDdmEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpAlmclientSfpAlmDdm table
1.3.6.1.4.1.20044.107.2.2.2.240.1.1Columnpm100gemuxsfpAlmclientSfpAlmDdmIndexread-onlycurrentIndex definition for the pm100gemuxsfpAlmclientSfpAlmDdm table
1.3.6.1.4.1.20044.107.2.2.2.240.1.2Columnpm100gemuxsfpAlmTxPwrLowAlaPortnread-onlycurrentClient Trscv Tx Power Low :This OID indicates that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in…
1.3.6.1.4.1.20044.107.2.2.2.240.1.3Columnpm100gemuxsfpAlmTxPwrHighAlaPortnread-onlycurrentClient Trscv Tx Power High :This OID indicates that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.107.2.2.2.240.1.4Columnpm100gemuxsfpAlmTxBiasLowAlaPortnread-onlycurrentClient Trscv Bias Low :This OID indicates that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.107.2.2.2.240.1.5Columnpm100gemuxsfpAlmTxBiasHighAlaPortnread-onlycurrentClient Trscv Bias High :This OID indicates that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM <Help> Alar…
1.3.6.1.4.1.20044.107.2.2.2.240.1.6Columnpm100gemuxsfpAlmVccLowAlaPortnread-onlycurrentClient Trscv Power Supply Low :This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM <Help> Alar…
1.3.6.1.4.1.20044.107.2.2.2.240.1.7Columnpm100gemuxsfpAlmVccHighAlaPortnread-onlycurrentClient Trscv Power Supply High :This OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM <Help> Al…
1.3.6.1.4.1.20044.107.2.2.2.240.1.8Columnpm100gemuxsfpAlmTempLowAlaPortnread-onlycurrentClient Trscv Temp Low :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicat…
1.3.6.1.4.1.20044.107.2.2.2.240.1.9Columnpm100gemuxsfpAlmTempHighAlaPortnread-onlycurrentClient Trscv Temp High :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indic…
1.3.6.1.4.1.20044.107.2.2.2.240.1.16Columnpm100gemuxsfpAlmRxPwrLowAlaPortnread-onlycurrentClient Trscv Rx Power Low :This OID indicates that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm ind…
1.3.6.1.4.1.20044.107.2.2.2.240.1.17Columnpm100gemuxsfpAlmRxPwrHighAlaPortnread-onlycurrentClient Trscv Rx Power High :This OID indicates that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm i…
1.3.6.1.4.1.20044.107.2.2.3Nodepm100gemuxsfpAlmClientCrit
1.3.6.1.4.1.20044.107.2.2.3.8Tablepm100gemuxsfpAlmsynthAlmPortTablenot-accessiblecurrentList of pm100gemuxsfpAlmsynthAlmPort Article
1.3.6.1.4.1.20044.107.2.2.3.8.1Rowpm100gemuxsfpAlmsynthAlmPortEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpAlmsynthAlmPort table
1.3.6.1.4.1.20044.107.2.2.3.8.1.1Columnpm100gemuxsfpAlmsynthAlmPortIndexread-onlycurrentIndex definition for the pm100gemuxsfpAlmsynthAlmPort table
1.3.6.1.4.1.20044.107.2.2.3.8.1.2Columnpm100gemuxsfpAlmSfpAbsentPortnread-onlycurrentClient Optical Module Absent :This OID indicates that the Transceiver is not present in the client port. <Help> This alarm indicates if the client transceiver …
1.3.6.1.4.1.20044.107.2.2.3.8.1.3Columnpm100gemuxsfpAlmDdmAbsentPortnread-onlycurrentDDM Supported On Client Trscv :This OID indicates that the Client transceiver supports the Digital Diagnostic Monitoring function <Help> This status indicates …
1.3.6.1.4.1.20044.107.2.2.3.8.1.5Columnpm100gemuxsfpAlmHwFailAccPortnread-onlycurrentClient HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Help> This alarm indicates a failure on client port, most pro…
1.3.6.1.4.1.20044.107.2.2.3.8.1.6Columnpm100gemuxsfpAlmDwLsdPortnread-onlycurrentClient Trscv Laser Shutdown :This OID indicates the Client transceiver laser is shutdown <Help> This status indicates if the client transceiver laser is shutdo…
1.3.6.1.4.1.20044.107.2.2.3.8.1.7Columnpm100gemuxsfpAlmClientLocalOosPortnread-onlycurrentLocal Client Port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local c…
1.3.6.1.4.1.20044.107.2.2.3.8.1.8Columnpm100gemuxsfpAlmClientRemoteOosPortnread-onlycurrentRemote Client Port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the remot…
1.3.6.1.4.1.20044.107.2.2.3.8.1.9Columnpm100gemuxsfpAlmDwCaisPortnread-onlycurrentClient AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indicates if a Client Alarm Indication Signal is…
1.3.6.1.4.1.20044.107.2.2.3.8.1.10Columnpm100gemuxsfpAlmSfpDdmWarningPortnread-onlycurrentWarning On Client Trscv DDM :This OID indicates a warning is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Warning has be…
1.3.6.1.4.1.20044.107.2.2.3.8.1.11Columnpm100gemuxsfpAlmSfpDdmAlmPortnread-onlycurrentAlarm On Client Trscv DDM :This OID indicates an alarm is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Alarm has been de…
1.3.6.1.4.1.20044.107.2.2.3.8.1.13Columnpm100gemuxsfpAlmFailAccPortnread-onlycurrentClient Access Fail :This OID indicates a failure on the Client port <Help> This alarm indicates a failure on the Client port <Condtype> FAIL_ACC_1 <Probcause> …
1.3.6.1.4.1.20044.107.2.2.3.8.1.17Columnpm100gemuxsfpAlmUpCsfPortnread-onlycurrentClient Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu…
1.3.6.1.4.1.20044.107.2.3Nodepm100gemuxsfpAlmLine
1.3.6.1.4.1.20044.107.2.3.1Nodepm100gemuxsfpAlmLineNurg
1.3.6.1.4.1.20044.107.2.3.1.72Tablepm100gemuxsfpAlmlineQsfpAlmDdmTablenot-accessiblecurrentList of pm100gemuxsfpAlmlineQsfpAlmDdm Article
1.3.6.1.4.1.20044.107.2.3.1.72.1Rowpm100gemuxsfpAlmlineQsfpAlmDdmEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpAlmlineQsfpAlmDdm table
1.3.6.1.4.1.20044.107.2.3.1.72.1.1Columnpm100gemuxsfpAlmlineQsfpAlmDdmIndexread-onlycurrentIndex definition for the pm100gemuxsfpAlmlineQsfpAlmDdm table
1.3.6.1.4.1.20044.107.2.3.1.72.1.2Columnpm100gemuxsfpAlmLineTxPwLowAlmPortnread-onlycurrentClient Trscv Tx Power Low Alarm :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indi…
1.3.6.1.4.1.20044.107.2.3.1.72.1.3Columnpm100gemuxsfpAlmLineTxPwrHighAlmPortnread-onlycurrentClient Trscv Tx Power High Alarm :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm in…
1.3.6.1.4.1.20044.107.2.3.1.72.1.4Columnpm100gemuxsfpAlmLineTxBiasLowAlmPortnread-onlycurrentClient Trscv Bias Low Alarm :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in…
1.3.6.1.4.1.20044.107.2.3.1.72.1.5Columnpm100gemuxsfpAlmLineTxBiasHighAlmPortnread-onlycurrentClient Trscv Bias High Alarm :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.107.2.3.1.72.1.6Columnpm100gemuxsfpAlmLineVccLowAlmPortnread-onlycurrentClient Trscv Power Supply Low Alarm :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.107.2.3.1.72.1.7Columnpm100gemuxsfpAlmLineVccHighAlmPortnread-onlycurrentClient Trscv Power Supply High Alarm :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Alar…
1.3.6.1.4.1.20044.107.2.3.1.72.1.8Columnpm100gemuxsfpAlmLineTempLowAlmPortnread-onlycurrentClient Trscv Temp Low Alarm :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicatin…
1.3.6.1.4.1.20044.107.2.3.1.72.1.9Columnpm100gemuxsfpAlmLineTempHighAlmPortnread-onlycurrentClient Trscv Temp High Alarm :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indicat…
1.3.6.1.4.1.20044.107.2.3.1.72.1.16Columnpm100gemuxsfpAlmLineRxPwrLowAlmPortnread-onlycurrentClient Trscv Rx Power Low Alarm :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indic…
1.3.6.1.4.1.20044.107.2.3.1.72.1.17Columnpm100gemuxsfpAlmLineRxPwrHighAlmPortnread-onlycurrentClient Trscv Rx Power High Alarm :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm ind…
1.3.6.1.4.1.20044.107.2.3.1.104Tablepm100gemuxsfpAlmlineQsfpWarnDdmTablenot-accessiblecurrentList of pm100gemuxsfpAlmlineQsfpWarnDdm Article
1.3.6.1.4.1.20044.107.2.3.1.104.1Rowpm100gemuxsfpAlmlineQsfpWarnDdmEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpAlmlineQsfpWarnDdm table
1.3.6.1.4.1.20044.107.2.3.1.104.1.1Columnpm100gemuxsfpAlmlineQsfpWarnDdmIndexread-onlycurrentIndex definition for the pm100gemuxsfpAlmlineQsfpWarnDdm table
1.3.6.1.4.1.20044.107.2.3.1.104.1.2Columnpm100gemuxsfpAlmLineTxPwLowWngPortnread-onlycurrentClient Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.107.2.3.1.104.1.3Columnpm100gemuxsfpAlmLineTxPwrHighWngPortnread-onlycurrentClient Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.107.2.3.1.104.1.4Columnpm100gemuxsfpAlmLineTxBiasLowWngPortnread-onlycurrentClient Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.107.2.3.1.104.1.5Columnpm100gemuxsfpAlmLineTxBiasHighWngPortnread-onlycurrentClient Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warn…
1.3.6.1.4.1.20044.107.2.3.1.104.1.6Columnpm100gemuxsfpAlmLineVccLowWngPortnread-onlycurrentClient Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Warn…
1.3.6.1.4.1.20044.107.2.3.1.104.1.7Columnpm100gemuxsfpAlmLineVccHighWngPortnread-onlycurrentClient Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Wa…
1.3.6.1.4.1.20044.107.2.3.1.104.1.8Columnpm100gemuxsfpAlmLineTempLowWngPortnread-onlycurrentClient Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indic…
1.3.6.1.4.1.20044.107.2.3.1.104.1.9Columnpm100gemuxsfpAlmLineTempHighWngPortnread-onlycurrentClient Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning ind…
1.3.6.1.4.1.20044.107.2.3.1.104.1.16Columnpm100gemuxsfpAlmLineRxPwrLowWngPortnread-onlycurrentClient Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning i…
1.3.6.1.4.1.20044.107.2.3.1.104.1.17Columnpm100gemuxsfpAlmLineRxPwrHighWngPortnread-onlycurrentClient Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning…
1.3.6.1.4.1.20044.107.2.3.1.184Tablepm100gemuxsfpAlmlineNetworkLaneAlarmWarning1Tablenot-accessiblecurrentList of pm100gemuxsfpAlmlineNetworkLaneAlarmWarning1 Article
1.3.6.1.4.1.20044.107.2.3.1.184.1Rowpm100gemuxsfpAlmlineNetworkLaneAlarmWarning1Entrynot-accessiblecurrentRow definition for the pm100gemuxsfpAlmlineNetworkLaneAlarmWarning1 table
1.3.6.1.4.1.20044.107.2.3.1.184.1.1Columnpm100gemuxsfpAlmlineNetworkLaneAlarmWarning1Indexread-onlycurrentIndex definition for the pm100gemuxsfpAlmlineNetworkLaneAlarmWarning1 table
1.3.6.1.4.1.20044.107.2.3.1.184.1.2Columnpm100gemuxsfpAlmLineRxPowerLowAlarmPortnread-onlycurrentLine Trscv Rx Power Low Alarm :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicat…
1.3.6.1.4.1.20044.107.2.3.1.184.1.3Columnpm100gemuxsfpAlmLineRxPowerLowWarningPortnread-onlycurrentLine Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning ind…
1.3.6.1.4.1.20044.107.2.3.1.184.1.4Columnpm100gemuxsfpAlmLineRxPowerHighWarningPortnread-onlycurrentLine Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning i…
1.3.6.1.4.1.20044.107.2.3.1.184.1.5Columnpm100gemuxsfpAlmLineRxPowerHighAlarmPortnread-onlycurrentLine Trscv Rx Power High Alarm :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indic…
1.3.6.1.4.1.20044.107.2.3.1.184.1.6Columnpm100gemuxsfpAlmLineLaserTempLowAlarmPortnread-onlycurrentLine Trscv Tx Laser Temp Low Alarm :This OID indicates that the Trscv Tx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help>…
1.3.6.1.4.1.20044.107.2.3.1.184.1.7Columnpm100gemuxsfpAlmLineLaserTempLowWarningPortnread-onlycurrentLine Trscv Tx Laser Temp Low Warning :This OID indicates that the Trscv Tx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Hel…
1.3.6.1.4.1.20044.107.2.3.1.184.1.8Columnpm100gemuxsfpAlmLineLaserTempHighWarningPortnread-onlycurrentLine Trscv Tx Laser Temp High Warning :This OID indicates that the Trscv Tx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <H…
1.3.6.1.4.1.20044.107.2.3.1.184.1.9Columnpm100gemuxsfpAlmLineLaserTempHighAlarmPortnread-onlycurrentLine Trscv Tx Laser Temp High Alarm :This OID indicates that the Trscv Tx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Hel…
1.3.6.1.4.1.20044.107.2.3.1.184.1.10Columnpm100gemuxsfpAlmLineTxPowerLowAlarmPortnread-onlycurrentLine Trscv Tx Power Low Alarm :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indica…
1.3.6.1.4.1.20044.107.2.3.1.184.1.11Columnpm100gemuxsfpAlmLineTxPowerLowWarningPortnread-onlycurrentLine Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning in…
1.3.6.1.4.1.20044.107.2.3.1.184.1.12Columnpm100gemuxsfpAlmLineTxPowerHighWarningPortnread-onlycurrentLine Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.107.2.3.1.184.1.13Columnpm100gemuxsfpAlmLineTxPowerHighAlarmPortnread-onlycurrentLine Trscv Tx Power High Alarm :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indi…
1.3.6.1.4.1.20044.107.2.3.1.184.1.14Columnpm100gemuxsfpAlmLineBiasLowAlarmPortnread-onlycurrentLine Trscv Tx Bias Low Alarm :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alarm i…
1.3.6.1.4.1.20044.107.2.3.1.184.1.15Columnpm100gemuxsfpAlmLineBiasLowWarningPortnread-onlycurrentLine Trscv Tx Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warni…
1.3.6.1.4.1.20044.107.2.3.1.184.1.16Columnpm100gemuxsfpAlmLineBiasHighWarningPortnread-onlycurrentLine Trscv Tx Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> War…
1.3.6.1.4.1.20044.107.2.3.1.184.1.17Columnpm100gemuxsfpAlmLineBiasHighAlarmPortnread-onlycurrentLine Trscv Tx Bias High Alarm :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Alarm…
1.3.6.1.4.1.20044.107.2.3.1.188Tablepm100gemuxsfpAlmlineNetworkLaneAlarmWarning2Tablenot-accessiblecurrentList of pm100gemuxsfpAlmlineNetworkLaneAlarmWarning2 Article
1.3.6.1.4.1.20044.107.2.3.1.188.1Rowpm100gemuxsfpAlmlineNetworkLaneAlarmWarning2Entrynot-accessiblecurrentRow definition for the pm100gemuxsfpAlmlineNetworkLaneAlarmWarning2 table
1.3.6.1.4.1.20044.107.2.3.1.188.1.1Columnpm100gemuxsfpAlmlineNetworkLaneAlarmWarning2Indexread-onlycurrentIndex definition for the pm100gemuxsfpAlmlineNetworkLaneAlarmWarning2 table
1.3.6.1.4.1.20044.107.2.3.1.188.1.2Columnpm100gemuxsfpAlmTxModulatorBiasLowAlarmPortnread-onlycurrentLine Trscv Tx Modulator Bias Low Alarm :This OID indicates that the Trscv Tx modulator bias current is lower than the threshold value written in the Trscv EEPR…
1.3.6.1.4.1.20044.107.2.3.1.188.1.3Columnpm100gemuxsfpAlmTxModulatorBiasLowWarningPortnread-onlycurrentLine Trscv Tx Modulator Bias Low Warning :This OID indicates that the Trscv Tx modulator bias current is lower than the threshold value written in the Trscv EE…
1.3.6.1.4.1.20044.107.2.3.1.188.1.4Columnpm100gemuxsfpAlmTxModulatorBiasHighWarningPortnread-onlycurrentLine Trscv Tx Modulator Bias High Warning :This OID indicates that the Trscv Tx modulator bias current is higher than the threshold value written in the Trscv …
1.3.6.1.4.1.20044.107.2.3.1.188.1.5Columnpm100gemuxsfpAlmTxModulatorBiasHighAlarmPortnread-onlycurrentLine Trscv Tx Modulator Bias High Alarm :This OID indicates that the Trscv Tx modulator bias current is higher than the threshold value written in the Trscv EE…
1.3.6.1.4.1.20044.107.2.3.1.188.1.6Columnpm100gemuxsfpAlmRxLaserTempLowAlarmPortnread-onlycurrentLine Trscv Rx Laser Temp Low Alarm :This OID indicates that the Trscv Rx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help>…
1.3.6.1.4.1.20044.107.2.3.1.188.1.7Columnpm100gemuxsfpAlmRxLaserTempLowWarningPortnread-onlycurrentLine Trscv Rx Laser Temp Low Warning :This OID indicates that the Trscv Rx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Hel…
1.3.6.1.4.1.20044.107.2.3.1.188.1.8Columnpm100gemuxsfpAlmRxLaserTempHighWarningPortnread-onlycurrentLine Trscv Rx Laser Temp High Warning :This OID indicates that the Trscv Rx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <H…
1.3.6.1.4.1.20044.107.2.3.1.188.1.9Columnpm100gemuxsfpAlmRxLaserTempHighAlarmPortnread-onlycurrentLine Trscv Rx Laser Temp High Alarm :This OID indicates that the Trscv Rx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Hel…
1.3.6.1.4.1.20044.107.2.3.1.188.1.10Columnpm100gemuxsfpAlmRxLaserOutputLowAlarmPortnread-onlycurrentLine Trscv Rx Output Power Low Alarm :This OID indicates that the Trscv Rx output power is lower than the threshold value written in the Trscv EEPROM <Help> Al…
1.3.6.1.4.1.20044.107.2.3.1.188.1.11Columnpm100gemuxsfpAlmRxLaserOutputLowWarningPortnread-onlycurrentLine Trscv Rx Output Power Low Warning :This OID indicates that the Trscv Rx output power is lower than the threshold value written in the Trscv EEPROM <Help> …
1.3.6.1.4.1.20044.107.2.3.1.188.1.12Columnpm100gemuxsfpAlmRxLaserOutputHighWarningPortnread-onlycurrentLine Trscv Rx Output Power High Warning :This OID indicates that the Trscv Rx output power is higher than the threshold value written in the Trscv EEPROM <Help…
1.3.6.1.4.1.20044.107.2.3.1.188.1.13Columnpm100gemuxsfpAlmRxLaserOutputHighAlarmPortnread-onlycurrentLine Trscv Rx Output Power High Alarm :This OID indicates that the Trscv Rx output power is higher than the threshold value written in the Trscv EEPROM <Help> …
1.3.6.1.4.1.20044.107.2.3.1.188.1.14Columnpm100gemuxsfpAlmRxLaserBiasLowAlarmPortnread-onlycurrentLine Trscv Rx Bias Low Alarm :This OID indicates that the Trscv Rx laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alar…
1.3.6.1.4.1.20044.107.2.3.1.188.1.15Columnpm100gemuxsfpAlmRxLaserBiasLowWarningPortnread-onlycurrentLine Trscv Rx Bias Low Warning :This OID indicates that the Trscv Rx laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Wa…
1.3.6.1.4.1.20044.107.2.3.1.188.1.16Columnpm100gemuxsfpAlmRxLaserBiasHighWarningPortnread-onlycurrentLine Trscv Rx Bias High Warning :This OID indicates that the Trscv Rx laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> …
1.3.6.1.4.1.20044.107.2.3.1.188.1.17Columnpm100gemuxsfpAlmRxLaserBiasHighAlarmPortnread-onlycurrentLine Trscv Rx Bias High Alarm :This OID indicates that the Trscv Rx laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Al…
1.3.6.1.4.1.20044.107.2.3.2Nodepm100gemuxsfpAlmLineUrg
1.3.6.1.4.1.20044.107.2.3.2.196Tablepm100gemuxsfpAlmlineHostLaneFaultTablenot-accessiblecurrentList of pm100gemuxsfpAlmlineHostLaneFault Article
1.3.6.1.4.1.20044.107.2.3.2.196.1Rowpm100gemuxsfpAlmlineHostLaneFaultEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpAlmlineHostLaneFault table
1.3.6.1.4.1.20044.107.2.3.2.196.1.1Columnpm100gemuxsfpAlmlineHostLaneFaultIndexread-onlycurrentIndex definition for the pm100gemuxsfpAlmlineHostLaneFault table
1.3.6.1.4.1.20044.107.2.3.2.196.1.2Columnpm100gemuxsfpAlmLineInputLossOfSignalPortnread-onlycurrentLine Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Line Trscv <Help> Alarm indicating a Loss of Signal is detected on the Line T…
1.3.6.1.4.1.20044.107.2.3.2.196.1.3Columnpm100gemuxsfpAlmLineLossOfFramePortnread-onlycurrentLine Loss Of Frame :This OID indicates the module is not aligned with the incoming Line signal <Help> Alarm indicating the module is not aligned with the incom…
1.3.6.1.4.1.20044.107.2.3.2.196.1.4Columnpm100gemuxsfpAlmLineSmBdiInsertedPortnread-onlycurrentLine SM BDI Inserted :This OID indicates a SM Backward Defect Indication is inserted on the outgoing Line signal <Help> Status indicating a SM Backward Defect …
1.3.6.1.4.1.20044.107.2.3.2.196.1.5Columnpm100gemuxsfpAlmLineSmBdiDetectedPortnread-onlycurrentLine SM BDI Detected :This OID indicates a SM Backward Defect Indication is detected on the incoming Line signal <Help> Alarm indicating a SM Backward Defect I…
1.3.6.1.4.1.20044.107.2.3.2.196.1.6Columnpm100gemuxsfpAlmLineSmIaeInsertedPortnread-onlycurrentLine SM IAE Inserted :This OID indicates a SM Incoming Alignment Error is inserted on the outgoing Line signal <Help> Status indicating a SM Incoming Alignment…
1.3.6.1.4.1.20044.107.2.3.2.196.1.7Columnpm100gemuxsfpAlmLineSmIaeDetectedPortnread-onlycurrentLine SM IAE Detected :This OID indicates a SM Incoming Alignment Error is detected on the incoming Line signal <Help> Alarm indicating a SM Incoming Alignment …
1.3.6.1.4.1.20044.107.2.3.2.196.1.15Columnpm100gemuxsfpAlmLineLinkStatusPortnread-onlycurrentLine Link Status :This OID indicates a Line linkup linkdown status <Help> This alarm indicates a Line linkup lindown status <Condtype> LINE_LINK_STATUS <Probca…
1.3.6.1.4.1.20044.107.2.3.2.196.1.16Columnpm100gemuxsfpAlmLineRxFaultPortnread-onlycurrentLine Rx Fault :This OID indicates a Line Rx fault on the receive path <Help> This alarm indicates a Line Rx fault on the receive path <Condtype> LINE_RX_FAULT …
1.3.6.1.4.1.20044.107.2.3.2.196.1.17Columnpm100gemuxsfpAlmLineTxFaultPortnread-onlycurrentLine Tx Fault :This OID indicates a Line Tx fault on the transmit path <Help> This alarm indicates a Line Tx fault on the transmit path <Condtype> LINE_TX_FAUL…
1.3.6.1.4.1.20044.107.2.3.3Nodepm100gemuxsfpAlmLineCrit
1.3.6.1.4.1.20044.107.2.3.3.40Tablepm100gemuxsfpAlmsynthAlmLineTablenot-accessiblecurrentList of pm100gemuxsfpAlmsynthAlmLine Article
1.3.6.1.4.1.20044.107.2.3.3.40.1Rowpm100gemuxsfpAlmsynthAlmLineEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpAlmsynthAlmLine table
1.3.6.1.4.1.20044.107.2.3.3.40.1.1Columnpm100gemuxsfpAlmsynthAlmLineIndexread-onlycurrentIndex definition for the pm100gemuxsfpAlmsynthAlmLine table
1.3.6.1.4.1.20044.107.2.3.3.40.1.2Columnpm100gemuxsfpAlmXfpAbsentPortnread-onlycurrentLine Optical Module Absent :This OID indicates that the line optical interface is not present. <Help> This alarm indicates if the line transceiver is not plugg…
1.3.6.1.4.1.20044.107.2.3.3.40.1.3Columnpm100gemuxsfpAlmXfpInitNotComplPortnread-onlycurrentLine Optical Module Ready :This OID indicates that the optical interface is not operational. <Help> This status indicates if the line transceiver has been corr…
1.3.6.1.4.1.20044.107.2.3.3.40.1.5Columnpm100gemuxsfpAlmLineHwFailPortnread-onlycurrentLine Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Help> This alarm indicates a failure on line port, most pr…
1.3.6.1.4.1.20044.107.2.3.3.40.1.6Columnpm100gemuxsfpAlmXfpTxOffPortnread-onlycurrentLine Trscv Laser Shutdown :This OID indicates the Line transceiver laser is shutdown <Help> This status indicates if the Line transceiver laser is shutdown <Co…
1.3.6.1.4.1.20044.107.2.3.3.40.1.7Columnpm100gemuxsfpAlmLineLocalOosPortnread-onlycurrentLine Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service…
1.3.6.1.4.1.20044.107.2.3.3.40.1.9Columnpm100gemuxsfpAlmUpRdiInsPortnread-onlycurrentMS-RDI/L-RDI Inserted On Line :This OID indicates an upstream MS-RDI/L-RDI has been inserted in the outgoing 10 Gb/s SDH/SONET signal. <Help> This status indic…
1.3.6.1.4.1.20044.107.2.3.3.40.1.10Columnpm100gemuxsfpAlmLineDdmWarningPortnread-onlycurrentWarning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Warning has…
1.3.6.1.4.1.20044.107.2.3.3.40.1.11Columnpm100gemuxsfpAlmLineDdmAlmPortnread-onlycurrentAlarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Alarm has been…
1.3.6.1.4.1.20044.107.2.3.3.40.1.13Columnpm100gemuxsfpAlmLineFailPortnread-onlycurrentLine Port Failure :This OID indicates a failure on the line port <Help> This alarm indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipm…
1.3.6.1.4.1.20044.107.2.3.3.40.1.17Columnpm100gemuxsfpAlmLineActivePortnread-onlycurrentLine Active :This OID indicates whether the line is active or standby. <Help> This status indicates whether the line is active or standby. <Condtype> LINE_ACTI…
1.3.6.1.4.1.20044.107.3Nodepm100gemuxsfpmeasures
1.3.6.1.4.1.20044.107.3.1Nodepm100gemuxsfpMesrOther
1.3.6.1.4.1.20044.107.3.1.0Scalarpm100gemuxsfpMesrsynth0read-onlydeprecatedNot Used :
1.3.6.1.4.1.20044.107.3.1.1Scalarpm100gemuxsfpMesrsynth1read-onlydeprecatedNot Used :
1.3.6.1.4.1.20044.107.3.1.7Scalarpm100gemuxsfpMesrpmIntervalNumberread-onlycurrentPM Interval Counter :
1.3.6.1.4.1.20044.107.3.1.252Scalarpm100gemuxsfpMesrregVoltageread-onlycurrentRegulator Voltage :This OID gives the voltage value of the Regulator (Voltage = AV_U16) (Unit = mV) <Help> This Measure gives the Regulator Voltage
1.3.6.1.4.1.20044.107.3.1.253Scalarpm100gemuxsfpMesrregCurrentread-onlycurrentRegulator Current :This OID gives the current value of the Regulator (Current = AV_U16/1000) (Unit = A) <Help> This Measure gives the Regulator Current
1.3.6.1.4.1.20044.107.3.1.254Scalarpm100gemuxsfpMesrregTempread-onlycurrentRegulator Temperature :This OID gives the temperature value of the Regulator (Temperature = AV_S16) (Unit = C) <Help> This Measure gives the Regulator Temperat…
1.3.6.1.4.1.20044.107.3.1.500Scalarpm100gemuxsfpMesrmoduleTempMinread-onlycurrentMin Module Temperature :This OID gives the minimum temperature value of the Module (Temperature = AV_S16/256) (Unit = C) <Help> This Measure gives the minimum …
1.3.6.1.4.1.20044.107.3.1.501Scalarpm100gemuxsfpMesrmoduleTempMaxread-onlycurrentMax Module Temperature :This OID gives the maximum temperature value of the Module (Temperature = AV_S16/256) (Unit = C) <Help> This Measure gives the maximum …
1.3.6.1.4.1.20044.107.3.2Nodepm100gemuxsfpMesrClient
1.3.6.1.4.1.20044.107.3.2.16Tablepm100gemuxsfpMesrclientTxTempTablenot-accessiblecurrentList of pm100gemuxsfpMesrclientTxTemp Article
1.3.6.1.4.1.20044.107.3.2.16.1Rowpm100gemuxsfpMesrclientTxTempEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMesrclientTxTemp table
1.3.6.1.4.1.20044.107.3.2.16.1.1Columnpm100gemuxsfpMesrclientTxTempIndexread-onlycurrentIndex definition for the pm100gemuxsfpMesrclientTxTemp table
1.3.6.1.4.1.20044.107.3.2.16.1.2Columnpm100gemuxsfpMesrclientTxTempPortnread-onlycurrentClient Trscv Temperature :This OID gives the Laser temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature …
1.3.6.1.4.1.20044.107.3.2.48Tablepm100gemuxsfpMesrclientTxBiasTablenot-accessiblecurrentList of pm100gemuxsfpMesrclientTxBias Article
1.3.6.1.4.1.20044.107.3.2.48.1Rowpm100gemuxsfpMesrclientTxBiasEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMesrclientTxBias table
1.3.6.1.4.1.20044.107.3.2.48.1.1Columnpm100gemuxsfpMesrclientTxBiasIndexread-onlycurrentIndex definition for the pm100gemuxsfpMesrclientTxBias table
1.3.6.1.4.1.20044.107.3.2.48.1.2Columnpm100gemuxsfpMesrclientTxBiasPortnread-onlycurrentClient Trscv Laser Bias :This OID gives the Laser bias value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV_U16/500) (…
1.3.6.1.4.1.20044.107.3.2.80Tablepm100gemuxsfpMesrclientTxPwrTablenot-accessiblecurrentList of pm100gemuxsfpMesrclientTxPwr Article
1.3.6.1.4.1.20044.107.3.2.80.1Rowpm100gemuxsfpMesrclientTxPwrEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMesrclientTxPwr table
1.3.6.1.4.1.20044.107.3.2.80.1.1Columnpm100gemuxsfpMesrclientTxPwrIndexread-onlycurrentIndex definition for the pm100gemuxsfpMesrclientTxPwr table
1.3.6.1.4.1.20044.107.3.2.80.1.2Columnpm100gemuxsfpMesrclientTxPwrPortnread-onlycurrentClient Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_…
1.3.6.1.4.1.20044.107.3.2.112Tablepm100gemuxsfpMesrclientRxPwrTablenot-accessiblecurrentList of pm100gemuxsfpMesrclientRxPwr Article
1.3.6.1.4.1.20044.107.3.2.112.1Rowpm100gemuxsfpMesrclientRxPwrEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMesrclientRxPwr table
1.3.6.1.4.1.20044.107.3.2.112.1.1Columnpm100gemuxsfpMesrclientRxPwrIndexread-onlycurrentIndex definition for the pm100gemuxsfpMesrclientRxPwr table
1.3.6.1.4.1.20044.107.3.2.112.1.2Columnpm100gemuxsfpMesrclientRxPwrPortnread-onlycurrentClient Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16…
1.3.6.1.4.1.20044.107.3.2.416Tablepm100gemuxsfpMesrclientTempMinTablenot-accessiblecurrentList of pm100gemuxsfpMesrclientTempMin Article
1.3.6.1.4.1.20044.107.3.2.416.1Rowpm100gemuxsfpMesrclientTempMinEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMesrclientTempMin table
1.3.6.1.4.1.20044.107.3.2.416.1.1Columnpm100gemuxsfpMesrclientTempMinIndexread-onlycurrentIndex definition for the pm100gemuxsfpMesrclientTempMin table
1.3.6.1.4.1.20044.107.3.2.416.1.2Columnpm100gemuxsfpMesrclientTempMinPortnread-onlycurrentMin Client Trscv Temperature :This OID gives the minimum temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temper…
1.3.6.1.4.1.20044.107.3.2.448Tablepm100gemuxsfpMesrclientTempMaxTablenot-accessiblecurrentList of pm100gemuxsfpMesrclientTempMax Article
1.3.6.1.4.1.20044.107.3.2.448.1Rowpm100gemuxsfpMesrclientTempMaxEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMesrclientTempMax table
1.3.6.1.4.1.20044.107.3.2.448.1.1Columnpm100gemuxsfpMesrclientTempMaxIndexread-onlycurrentIndex definition for the pm100gemuxsfpMesrclientTempMax table
1.3.6.1.4.1.20044.107.3.2.448.1.2Columnpm100gemuxsfpMesrclientTempMaxPortnread-onlycurrentMax Client Trscv Temperature :This OID gives the maximum temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temper…
1.3.6.1.4.1.20044.107.3.3Nodepm100gemuxsfpMesrLine
1.3.6.1.4.1.20044.107.3.3.12Scalarpm100gemuxsfpMesrlineMsaTempread-onlycurrentLine Trscv Temperature :This OID gives the temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV_S16/2…
1.3.6.1.4.1.20044.107.3.3.13Scalarpm100gemuxsfpMesrlineMsa3v3Voltageread-onlycurrentLine Trscv Voltage :This OID gives the 3V3 voltage value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV_U16/10000) (U…
1.3.6.1.4.1.20044.107.3.3.144Tablepm100gemuxsfpMesrlineTxPwrMinTablenot-accessiblecurrentList of pm100gemuxsfpMesrlineTxPwrMin Article
1.3.6.1.4.1.20044.107.3.3.144.1Rowpm100gemuxsfpMesrlineTxPwrMinEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMesrlineTxPwrMin table
1.3.6.1.4.1.20044.107.3.3.144.1.1Columnpm100gemuxsfpMesrlineTxPwrMinIndexread-onlycurrentIndex definition for the pm100gemuxsfpMesrlineTxPwrMin table
1.3.6.1.4.1.20044.107.3.3.144.1.2Columnpm100gemuxsfpMesrlineTxPwrMinPortnread-onlycurrentMin Line Trscv Tx Power :This OID gives the minimum transmit power value among the network lanes of the Line Transceiver, read from the DDM (Digital Diagnostic…
1.3.6.1.4.1.20044.107.3.3.160Tablepm100gemuxsfpMesrlineTxCompositePwrTablenot-accessiblecurrentList of pm100gemuxsfpMesrlineTxCompositePwr Article
1.3.6.1.4.1.20044.107.3.3.160.1Rowpm100gemuxsfpMesrlineTxCompositePwrEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMesrlineTxCompositePwr table
1.3.6.1.4.1.20044.107.3.3.160.1.1Columnpm100gemuxsfpMesrlineTxCompositePwrIndexread-onlycurrentIndex definition for the pm100gemuxsfpMesrlineTxCompositePwr table
1.3.6.1.4.1.20044.107.3.3.160.1.2Columnpm100gemuxsfpMesrlineTxCompositePwrPortnread-onlycurrentLine Composite Tx Power (LR4/SR4) :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Line Transceiver, read from the…
1.3.6.1.4.1.20044.107.3.3.176Tablepm100gemuxsfpMesrlineRxPwrMinTablenot-accessiblecurrentList of pm100gemuxsfpMesrlineRxPwrMin Article
1.3.6.1.4.1.20044.107.3.3.176.1Rowpm100gemuxsfpMesrlineRxPwrMinEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMesrlineRxPwrMin table
1.3.6.1.4.1.20044.107.3.3.176.1.1Columnpm100gemuxsfpMesrlineRxPwrMinIndexread-onlycurrentIndex definition for the pm100gemuxsfpMesrlineRxPwrMin table
1.3.6.1.4.1.20044.107.3.3.176.1.2Columnpm100gemuxsfpMesrlineRxPwrMinPortnread-onlycurrentMin Line Trscv Rx Power :This OID gives the minimum receive power value among the network lanes of the Line Transceiver, read from the DDM (Digital Diagnostic …
1.3.6.1.4.1.20044.107.3.3.192Tablepm100gemuxsfpMesrlineRxCompositePwrTablenot-accessiblecurrentList of pm100gemuxsfpMesrlineRxCompositePwr Article
1.3.6.1.4.1.20044.107.3.3.192.1Rowpm100gemuxsfpMesrlineRxCompositePwrEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMesrlineRxCompositePwr table
1.3.6.1.4.1.20044.107.3.3.192.1.1Columnpm100gemuxsfpMesrlineRxCompositePwrIndexread-onlycurrentIndex definition for the pm100gemuxsfpMesrlineRxCompositePwr table
1.3.6.1.4.1.20044.107.3.3.192.1.2Columnpm100gemuxsfpMesrlineRxCompositePwrPortnread-onlycurrentLine Composite Rx Power (LR4/SR4) :This OID gives the composite receive power (sum of the network lanes receive power) of the Line Transceiver, read from the D…
1.3.6.1.4.1.20044.107.3.3.208Tablepm100gemuxsfpMesrlineTxPwrMaxTablenot-accessiblecurrentList of pm100gemuxsfpMesrlineTxPwrMax Article
1.3.6.1.4.1.20044.107.3.3.208.1Rowpm100gemuxsfpMesrlineTxPwrMaxEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMesrlineTxPwrMax table
1.3.6.1.4.1.20044.107.3.3.208.1.1Columnpm100gemuxsfpMesrlineTxPwrMaxIndexread-onlycurrentIndex definition for the pm100gemuxsfpMesrlineTxPwrMax table
1.3.6.1.4.1.20044.107.3.3.208.1.2Columnpm100gemuxsfpMesrlineTxPwrMaxPortnread-onlycurrentMax Line Trscv Tx Power :This OID gives the maximum transmit power value among the network lanes of the Line Transceiver, read from the DDM (Digital Diagnostic…
1.3.6.1.4.1.20044.107.3.3.224Tablepm100gemuxsfpMesrlineRxPwrMaxTablenot-accessiblecurrentList of pm100gemuxsfpMesrlineRxPwrMax Article
1.3.6.1.4.1.20044.107.3.3.224.1Rowpm100gemuxsfpMesrlineRxPwrMaxEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMesrlineRxPwrMax table
1.3.6.1.4.1.20044.107.3.3.224.1.1Columnpm100gemuxsfpMesrlineRxPwrMaxIndexread-onlycurrentIndex definition for the pm100gemuxsfpMesrlineRxPwrMax table
1.3.6.1.4.1.20044.107.3.3.224.1.2Columnpm100gemuxsfpMesrlineRxPwrMaxPortnread-onlycurrentMax Line Trscv Rx Power :This OID gives the maximum receive power value among the network lanes of the Line Transceiver, read in the DDM (Digital Diagnostic Mo…
1.3.6.1.4.1.20044.107.3.3.492Scalarpm100gemuxsfpMesrlineTempMinread-onlycurrentMin Line Trscv Temperature :This OID gives the minimum temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperatur…
1.3.6.1.4.1.20044.107.3.3.496Scalarpm100gemuxsfpMesrlineTempMaxread-onlycurrentMax Line Trscv Temperature :This OID gives the maximum temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperatur…
1.3.6.1.4.1.20044.107.4Nodepm100gemuxsfpcounters
1.3.6.1.4.1.20044.107.4.1Nodepm100gemuxsfpCntOther
1.3.6.1.4.1.20044.107.4.2Nodepm100gemuxsfpCntClient
1.3.6.1.4.1.20044.107.4.2.112Tablepm100gemuxsfpCntclientInputErrorCounterTablenot-accessiblecurrentList of pm100gemuxsfpCntclientInputErrorCounter Article
1.3.6.1.4.1.20044.107.4.2.112.1Rowpm100gemuxsfpCntclientInputErrorCounterEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpCntclientInputErrorCounter table
1.3.6.1.4.1.20044.107.4.2.112.1.1Columnpm100gemuxsfpCntclientInputErrorCounterIndexread-onlycurrentIndex definition for the pm100gemuxsfpCntclientInputErrorCounter table
1.3.6.1.4.1.20044.107.4.2.112.1.2Columnpm100gemuxsfpCntclientInputErrorCounterValuePortnread-onlycurrentClient Input Errors :This counter gives the number of SM-BIP8 (OTU4) or 66B/64B disparities (100GbE) on client port <Help> This counter gives the number of SM-…
1.3.6.1.4.1.20044.107.4.2.112.1.3Columnpm100gemuxsfpCntclientInputErrorCounterErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the BIP8 error counter value is invalid on Port
1.3.6.1.4.1.20044.107.4.2.112.1.4Columnpm100gemuxsfpCntclientInputErrorCounterOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a BIP8 error counter overload on Port
1.3.6.1.4.1.20044.107.4.2.144Tablepm100gemuxsfpCntclientCbipCounterTablenot-accessiblecurrentList of pm100gemuxsfpCntclientCbipCounter Article
1.3.6.1.4.1.20044.107.4.2.144.1Rowpm100gemuxsfpCntclientCbipCounterEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpCntclientCbipCounter table
1.3.6.1.4.1.20044.107.4.2.144.1.1Columnpm100gemuxsfpCntclientCbipCounterIndexread-onlycurrentIndex definition for the pm100gemuxsfpCntclientCbipCounter table
1.3.6.1.4.1.20044.107.4.2.144.1.2Columnpm100gemuxsfpCntclientCbipCounterValuePortnread-onlycurrentClient Output Errors :This counter gives the number of SM-BIP8 (OTU4) or 66B/64B disparities (100GbE) on client port <Help> This counter gives the number of SM…
1.3.6.1.4.1.20044.107.4.2.144.1.3Columnpm100gemuxsfpCntclientCbipCounterErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the BIP8 error counter value is invalid on Port
1.3.6.1.4.1.20044.107.4.2.144.1.4Columnpm100gemuxsfpCntclientCbipCounterOverloadPortnread-onlycurrentClient CBIP Counter Overload :This OID when set indicates a BIP8 error counter overload on Port
1.3.6.1.4.1.20044.107.4.3Nodepm100gemuxsfpCntLine
1.3.6.1.4.1.20044.107.4.3.192Tablepm100gemuxsfpCntlocalLineSmBip8ErrorCounterTablenot-accessiblecurrentList of pm100gemuxsfpCntlocalLineSmBip8ErrorCounter Article
1.3.6.1.4.1.20044.107.4.3.192.1Rowpm100gemuxsfpCntlocalLineSmBip8ErrorCounterEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpCntlocalLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.107.4.3.192.1.1Columnpm100gemuxsfpCntlocalLineSmBip8ErrorCounterIndexread-onlycurrentIndex definition for the pm100gemuxsfpCntlocalLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.107.4.3.192.1.2Columnpm100gemuxsfpCntlocalLineSmBip8ErrorCounterValuePortnread-onlycurrentUncorrected FEC Errors :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC <Help> This counter gives the current Bit Error Rate (resi…
1.3.6.1.4.1.20044.107.4.3.192.1.3Columnpm100gemuxsfpCntlocalLineSmBip8ErrorCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the B1 error counter value is invalid on Port
1.3.6.1.4.1.20044.107.4.3.192.1.4Columnpm100gemuxsfpCntlocalLineSmBip8ErrorCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a B1 error counter overload on Port
1.3.6.1.4.1.20044.107.4.3.193Tablepm100gemuxsfpCntlocalLineFecCorrectedErrorsCounterTablenot-accessiblecurrentList of pm100gemuxsfpCntlocalLineFecCorrectedErrorsCounter Article
1.3.6.1.4.1.20044.107.4.3.193.1Rowpm100gemuxsfpCntlocalLineFecCorrectedErrorsCounterEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpCntlocalLineFecCorrectedErrorsCounter table
1.3.6.1.4.1.20044.107.4.3.193.1.1Columnpm100gemuxsfpCntlocalLineFecCorrectedErrorsCounterIndexread-onlycurrentIndex definition for the pm100gemuxsfpCntlocalLineFecCorrectedErrorsCounter table
1.3.6.1.4.1.20044.107.4.3.193.1.2Columnpm100gemuxsfpCntlocalLineFecCorrectedErrorsCounterValuePortnread-onlycurrentLine Input HD FEC Corrected Errors :This OID gives the current Bit Error Rate before the Hard Decision FEC <Help> This counter gives the current Bit Error Rate…
1.3.6.1.4.1.20044.107.4.3.193.1.3Columnpm100gemuxsfpCntlocalLineFecCorrectedErrorsCounterErrorPortnread-onlycurrentFEC Counter Error :This bit when set indicates the FEC corrected errors counter value is invalid on Line
1.3.6.1.4.1.20044.107.4.3.193.1.4Columnpm100gemuxsfpCntlocalLineFecCorrectedErrorsCounterOverloadPortnread-onlycurrentFEC Counter Overload :This bit when set indicates a FEC corrected errors counter overload on Line
1.3.6.1.4.1.20044.107.4.3.194Tablepm100gemuxsfpCntremoteLineSmBip8ErrorCounterTablenot-accessiblecurrentList of pm100gemuxsfpCntremoteLineSmBip8ErrorCounter Article
1.3.6.1.4.1.20044.107.4.3.194.1Rowpm100gemuxsfpCntremoteLineSmBip8ErrorCounterEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpCntremoteLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.107.4.3.194.1.1Columnpm100gemuxsfpCntremoteLineSmBip8ErrorCounterIndexread-onlycurrentIndex definition for the pm100gemuxsfpCntremoteLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.107.4.3.194.1.2Columnpm100gemuxsfpCntremoteLineSmBip8ErrorCounterValuePortnread-onlycurrentRemote SM BIP8 :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC on the remote side <Help> This counter gives the current Bit Error…
1.3.6.1.4.1.20044.107.4.3.194.1.3Columnpm100gemuxsfpCntremoteLineSmBip8ErrorCounterErrorPortnread-onlycurrentRemote Counter Error :
1.3.6.1.4.1.20044.107.4.3.194.1.4Columnpm100gemuxsfpCntremoteLineSmBip8ErrorCounterOverloadPortnread-onlycurrentRemote Counter Overload :
1.3.6.1.4.1.20044.107.4.3.195Tablepm100gemuxsfpCntlineDfrmTimCntTablenot-accessiblecurrentList of pm100gemuxsfpCntlineDfrmTimCnt Article
1.3.6.1.4.1.20044.107.4.3.195.1Rowpm100gemuxsfpCntlineDfrmTimCntEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpCntlineDfrmTimCnt table
1.3.6.1.4.1.20044.107.4.3.195.1.1Columnpm100gemuxsfpCntlineDfrmTimCntIndexread-onlycurrentIndex definition for the pm100gemuxsfpCntlineDfrmTimCnt table
1.3.6.1.4.1.20044.107.4.3.195.1.2Columnpm100gemuxsfpCntlineDfrmTimCntValuePortnread-onlycurrentLine Timer Counter :
1.3.6.1.4.1.20044.107.4.3.195.1.3Columnpm100gemuxsfpCntlineDfrmTimCntErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.107.4.3.195.1.4Columnpm100gemuxsfpCntlineDfrmTimCntOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.107.4.3.196Tablepm100gemuxsfpCntlocalLineTrscvPreSdFecErrorCounterTablenot-accessiblecurrentList of pm100gemuxsfpCntlocalLineTrscvPreSdFecErrorCounter Article
1.3.6.1.4.1.20044.107.4.3.196.1Rowpm100gemuxsfpCntlocalLineTrscvPreSdFecErrorCounterEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpCntlocalLineTrscvPreSdFecErrorCounter table
1.3.6.1.4.1.20044.107.4.3.196.1.1Columnpm100gemuxsfpCntlocalLineTrscvPreSdFecErrorCounterIndexread-onlycurrentIndex definition for the pm100gemuxsfpCntlocalLineTrscvPreSdFecErrorCounter table
1.3.6.1.4.1.20044.107.4.3.196.1.2Columnpm100gemuxsfpCntlocalLineTrscvPreSdFecErrorCounterValuePortnread-onlycurrentPre FEC Errors :This OID gives the current Bit Error Rate before the FEC <Help> This counter gives the current Bit Error Rate before the FEC
1.3.6.1.4.1.20044.107.4.3.196.1.3Columnpm100gemuxsfpCntlocalLineTrscvPreSdFecErrorCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.107.4.3.196.1.4Columnpm100gemuxsfpCntlocalLineTrscvPreSdFecErrorCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.107.4.3.197Tablepm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecErrorCounterTablenot-accessiblecurrentList of pm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecErrorCounter Article
1.3.6.1.4.1.20044.107.4.3.197.1Rowpm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecErrorCounterEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecErrorCounter table
1.3.6.1.4.1.20044.107.4.3.197.1.1Columnpm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecErrorCounterIndexread-onlycurrentIndex definition for the pm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecErrorCounter table
1.3.6.1.4.1.20044.107.4.3.197.1.2Columnpm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecErrorCounterValuePortnread-onlycurrentUncorrected FEC Errors :This OID gives the current Bit Error Rate after the Soft Decision FEC (residual) <Help> This counter gives the current Bit Error Rate a…
1.3.6.1.4.1.20044.107.4.3.197.1.3Columnpm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecErrorCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.107.4.3.197.1.4Columnpm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecErrorCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.107.4.3.198Tablepm100gemuxsfpCntlocalLineTrscvPreSdFecBitCounterTablenot-accessiblecurrentList of pm100gemuxsfpCntlocalLineTrscvPreSdFecBitCounter Article
1.3.6.1.4.1.20044.107.4.3.198.1Rowpm100gemuxsfpCntlocalLineTrscvPreSdFecBitCounterEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpCntlocalLineTrscvPreSdFecBitCounter table
1.3.6.1.4.1.20044.107.4.3.198.1.1Columnpm100gemuxsfpCntlocalLineTrscvPreSdFecBitCounterIndexread-onlycurrentIndex definition for the pm100gemuxsfpCntlocalLineTrscvPreSdFecBitCounter table
1.3.6.1.4.1.20044.107.4.3.198.1.2Columnpm100gemuxsfpCntlocalLineTrscvPreSdFecBitCounterValuePortnread-onlycurrentPre-SD FEC Bit Counter :This OID gives the current Bit count before the Soft Decision FEC <Help> This counter gives the current Bit Count before the Soft Decis…
1.3.6.1.4.1.20044.107.4.3.198.1.3Columnpm100gemuxsfpCntlocalLineTrscvPreSdFecBitCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.107.4.3.198.1.4Columnpm100gemuxsfpCntlocalLineTrscvPreSdFecBitCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.107.4.3.199Tablepm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecBitCounterTablenot-accessiblecurrentList of pm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecBitCounter Article
1.3.6.1.4.1.20044.107.4.3.199.1Rowpm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecBitCounterEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecBitCounter table
1.3.6.1.4.1.20044.107.4.3.199.1.1Columnpm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecBitCounterIndexread-onlycurrentIndex definition for the pm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecBitCounter table
1.3.6.1.4.1.20044.107.4.3.199.1.2Columnpm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecBitCounterValuePortnread-onlycurrentUncorrected SD FEC Bit Counter :This OID gives the current Bit count after the Soft Decision FEC (residual) <Help> This counter gives the current Bit Count aft…
1.3.6.1.4.1.20044.107.4.3.199.1.3Columnpm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecBitCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.107.4.3.199.1.4Columnpm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecBitCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.107.6Nodepm100gemuxsfpcontrolsWrite
1.3.6.1.4.1.20044.107.6.1Nodepm100gemuxsfpCtrlOther
1.3.6.1.4.1.20044.107.6.1.1Nodepm100gemuxsfpCtrlconfMgnt1
1.3.6.1.4.1.20044.107.6.1.1.1Scalarpm100gemuxsfpCtrlConf1Load1read-writecurrentLoad Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM.
1.3.6.1.4.1.20044.107.6.1.1.2Scalarpm100gemuxsfpCtrlConf2Load1read-writecurrentLoad Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM.
1.3.6.1.4.1.20044.107.6.1.1.10Scalarpm100gemuxsfpCtrlConf2Flash1read-writecurrentWrite Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura…
1.3.6.1.4.1.20044.107.6.1.1.14Scalarpm100gemuxsfpCtrlConf2Clear1read-writecurrentClear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o…
1.3.6.1.4.1.20044.107.6.1.4Nodepm100gemuxsfpCtrlsynth4
1.3.6.1.4.1.20044.107.6.1.4.1Scalarpm100gemuxsfpCtrlCorrelatOnread-writecurrentEnable Alarm Correlation :This OID enables the alarm correlation in the PM.
1.3.6.1.4.1.20044.107.6.1.4.2Scalarpm100gemuxsfpCtrlCorrelatOffread-writecurrentDisable Alarm Correlation :This OID disables the alarm correlation in the PM.
1.3.6.1.4.1.20044.107.6.1.5Nodepm100gemuxsfpCtrlswMgnt
1.3.6.1.4.1.20044.107.6.1.5.2Scalarpm100gemuxsfpCtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> …
1.3.6.1.4.1.20044.107.6.1.5.3Scalarpm100gemuxsfpCtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th…
1.3.6.1.4.1.20044.107.6.1.5.5Scalarpm100gemuxsfpCtrlLoadSwBank1read-writecurrentSet Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW…
1.3.6.1.4.1.20044.107.6.1.5.6Scalarpm100gemuxsfpCtrlLoadSwBank2read-writecurrentSet Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S…
1.3.6.1.4.1.20044.107.6.1.6Nodepm100gemuxsfpCtrlgwMgnt
1.3.6.1.4.1.20044.107.6.1.6.1Scalarpm100gemuxsfpCtrlCurrentGwResetread-writecurrentActive Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting.
1.3.6.1.4.1.20044.107.6.1.6.5Scalarpm100gemuxsfpCtrlLoadGwBank1read-writecurrentSet Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.107.6.1.6.6Scalarpm100gemuxsfpCtrlLoadGwBank2read-writecurrentSet Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.107.6.1.6.7Scalarpm100gemuxsfpCtrlLoadGwBank3read-writecurrentSet Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.107.6.1.6.8Scalarpm100gemuxsfpCtrlLoadGwBank4read-writecurrentSet Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.107.6.1.192Nodepm100gemuxsfpCtrlledTest
1.3.6.1.4.1.20044.107.6.1.192.1Scalarpm100gemuxsfpCtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.107.6.1.192.2Scalarpm100gemuxsfpCtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.107.6.1.192.3Scalarpm100gemuxsfpCtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.107.6.1.201Nodepm100gemuxsfpCtrlinitSwitchMarvell
1.3.6.1.4.1.20044.107.6.1.201.1Scalarpm100gemuxsfpCtrlInitSwitchMarvellread-writecurrentSwitch Initialization :This OID operates an initialization of the switch managed through the module <Help> This control activates an initialization of the swit…
1.3.6.1.4.1.20044.107.6.1.259Nodepm100gemuxsfpCtrlresetCount
1.3.6.1.4.1.20044.107.6.1.259.1Scalarpm100gemuxsfpCtrlResetcountread-writecurrentModule Count Global Reset :This OID resets all the errors counters on the module <Help > This control initiates a reset of the errors counters on the module
1.3.6.1.4.1.20044.107.6.1.260Nodepm100gemuxsfpCtrlresetRmon
1.3.6.1.4.1.20044.107.6.1.260.1Scalarpm100gemuxsfpCtrlResetrmonread-writecurrentModule Rmon Global Reset :This OID resets all the Rmon counters on the module <Help > This control initiates a reset of the Rmon counters on the module
1.3.6.1.4.1.20044.107.6.1.261Nodepm100gemuxsfpCtrlresetMeasurements
1.3.6.1.4.1.20044.107.6.1.261.1Scalarpm100gemuxsfpCtrlResetmeasurementsread-writecurrentManagement Meas Global Reset :This OID resets some measurements on the management <Help > This control initiates a reset of some measurements on the management
1.3.6.1.4.1.20044.107.6.2Nodepm100gemuxsfpCtrlClient
1.3.6.1.4.1.20044.107.6.2.16Tablepm100gemuxsfpCtrlaccessLoopTablenot-accessiblecurrentList of pm100gemuxsfpCtrlaccessLoop Article
1.3.6.1.4.1.20044.107.6.2.16.1Rowpm100gemuxsfpCtrlaccessLoopEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpCtrlaccessLoop table
1.3.6.1.4.1.20044.107.6.2.16.1.1Columnpm100gemuxsfpCtrlaccessLoopIndexread-onlycurrentIndex definition for the pm100gemuxsfpCtrlaccessLoop table
1.3.6.1.4.1.20044.107.6.2.16.1.2Columnpm100gemuxsfpCtrlaccessLoopPortnread-writecurrentClient Facility Loopback :This OID, when set at '1' puts the client port in loopback, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. <Help…
1.3.6.1.4.1.20044.107.6.2.17Tablepm100gemuxsfpCtrlclientLoopToLineTablenot-accessiblecurrentList of pm100gemuxsfpCtrlclientLoopToLine Article
1.3.6.1.4.1.20044.107.6.2.17.1Rowpm100gemuxsfpCtrlclientLoopToLineEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpCtrlclientLoopToLine table
1.3.6.1.4.1.20044.107.6.2.17.1.1Columnpm100gemuxsfpCtrlclientLoopToLineIndexread-onlycurrentIndex definition for the pm100gemuxsfpCtrlclientLoopToLine table
1.3.6.1.4.1.20044.107.6.2.17.1.2Columnpm100gemuxsfpCtrlclientLoopToLinePortnread-writecurrentClient Terminal Loopback :This OID, when set, puts the client port in loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.<Help> This control ena…
1.3.6.1.4.1.20044.107.6.2.21Tablepm100gemuxsfpCtrlcsfUpInsTablenot-accessiblecurrentList of pm100gemuxsfpCtrlcsfUpIns Article
1.3.6.1.4.1.20044.107.6.2.21.1Rowpm100gemuxsfpCtrlcsfUpInsEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpCtrlcsfUpIns table
1.3.6.1.4.1.20044.107.6.2.21.1.1Columnpm100gemuxsfpCtrlcsfUpInsIndexread-onlycurrentIndex definition for the pm100gemuxsfpCtrlcsfUpIns table
1.3.6.1.4.1.20044.107.6.2.21.1.2Columnpm100gemuxsfpCtrlcsfUpInsPortnread-writecurrentClient Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo…
1.3.6.1.4.1.20044.107.6.2.22Tablepm100gemuxsfpCtrlcaisDwInsTablenot-accessiblecurrentList of pm100gemuxsfpCtrlcaisDwIns Article
1.3.6.1.4.1.20044.107.6.2.22.1Rowpm100gemuxsfpCtrlcaisDwInsEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpCtrlcaisDwIns table
1.3.6.1.4.1.20044.107.6.2.22.1.1Columnpm100gemuxsfpCtrlcaisDwInsIndexread-onlycurrentIndex definition for the pm100gemuxsfpCtrlcaisDwIns table
1.3.6.1.4.1.20044.107.6.2.22.1.2Columnpm100gemuxsfpCtrlcaisDwInsPortnread-writecurrentClient AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port
1.3.6.1.4.1.20044.107.6.2.262Tablepm100gemuxsfpCtrlclientResetAllCountTablenot-accessiblecurrentList of pm100gemuxsfpCtrlclientResetAllCount Article
1.3.6.1.4.1.20044.107.6.2.262.1Rowpm100gemuxsfpCtrlclientResetAllCountEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpCtrlclientResetAllCount table
1.3.6.1.4.1.20044.107.6.2.262.1.1Columnpm100gemuxsfpCtrlclientResetAllCountIndexread-onlycurrentIndex definition for the pm100gemuxsfpCtrlclientResetAllCount table
1.3.6.1.4.1.20044.107.6.2.262.1.2Columnpm100gemuxsfpCtrlclientResetAllCountsPortnread-writecurrentClient Counters Reset :This OID resets every counter on the client port <Help> This control operates a reset on the statistics current ,previous and history cl…
1.3.6.1.4.1.20044.107.6.3Nodepm100gemuxsfpCtrlLine
1.3.6.1.4.1.20044.107.6.3.64Tablepm100gemuxsfpCtrlcommAccessLoopTablenot-accessiblecurrentList of pm100gemuxsfpCtrlcommAccessLoop Article
1.3.6.1.4.1.20044.107.6.3.64.1Rowpm100gemuxsfpCtrlcommAccessLoopEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpCtrlcommAccessLoop table
1.3.6.1.4.1.20044.107.6.3.64.1.1Columnpm100gemuxsfpCtrlcommAccessLoopIndexread-onlycurrentIndex definition for the pm100gemuxsfpCtrlcommAccessLoop table
1.3.6.1.4.1.20044.107.6.3.64.1.2Columnpm100gemuxsfpCtrlcommAccessLoopPortnread-writecurrentLine Terminal Loopback :This OID, when set, puts the module in common access loop back, looping the 200 Gb/s output signal on the 200 Gb/s input.<Help> This co…
1.3.6.1.4.1.20044.107.6.3.66Tablepm100gemuxsfpCtrllineLoopTablenot-accessiblecurrentList of pm100gemuxsfpCtrllineLoop Article
1.3.6.1.4.1.20044.107.6.3.66.1Rowpm100gemuxsfpCtrllineLoopEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpCtrllineLoop table
1.3.6.1.4.1.20044.107.6.3.66.1.1Columnpm100gemuxsfpCtrllineLoopIndexread-onlycurrentIndex definition for the pm100gemuxsfpCtrllineLoop table
1.3.6.1.4.1.20044.107.6.3.66.1.2Columnpm100gemuxsfpCtrllineLoopPortnread-writecurrentLine Facility Loopback :This OID, when set at '1' puts the module in line loopback mode, looping the received 200 Gb/s signal on the transmit 200 Gb/s output. …
1.3.6.1.4.1.20044.107.6.3.69Tablepm100gemuxsfpCtrlfecDisableTablenot-accessiblecurrentList of pm100gemuxsfpCtrlfecDisable Article
1.3.6.1.4.1.20044.107.6.3.69.1Rowpm100gemuxsfpCtrlfecDisableEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpCtrlfecDisable table
1.3.6.1.4.1.20044.107.6.3.69.1.1Columnpm100gemuxsfpCtrlfecDisableIndexread-onlycurrentIndex definition for the pm100gemuxsfpCtrlfecDisable table
1.3.6.1.4.1.20044.107.6.3.69.1.2Columnpm100gemuxsfpCtrlfecDisablePortnread-writecurrentForward Error Correction Inhibition :This OID, when set, inhibits the Forward Error Correction feature on the line input <Help> This control enables/disables t…
1.3.6.1.4.1.20044.107.6.3.209Tablepm100gemuxsfpCtrlmsaLineLoopTablenot-accessiblecurrentList of pm100gemuxsfpCtrlmsaLineLoop Article
1.3.6.1.4.1.20044.107.6.3.209.1Rowpm100gemuxsfpCtrlmsaLineLoopEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpCtrlmsaLineLoop table
1.3.6.1.4.1.20044.107.6.3.209.1.1Columnpm100gemuxsfpCtrlmsaLineLoopIndexread-onlycurrentIndex definition for the pm100gemuxsfpCtrlmsaLineLoop table
1.3.6.1.4.1.20044.107.6.3.209.1.2Columnpm100gemuxsfpCtrlmsaLineLoopPortnread-writecurrentMSA Line Loop :This OID operates a line loopback on the MSA Line <Help> This control defines the line loop back of the line transceiver
1.3.6.1.4.1.20044.107.6.3.210Tablepm100gemuxsfpCtrlmsaRestartTablenot-accessiblecurrentList of pm100gemuxsfpCtrlmsaRestart Article
1.3.6.1.4.1.20044.107.6.3.210.1Rowpm100gemuxsfpCtrlmsaRestartEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpCtrlmsaRestart table
1.3.6.1.4.1.20044.107.6.3.210.1.1Columnpm100gemuxsfpCtrlmsaRestartIndexread-onlycurrentIndex definition for the pm100gemuxsfpCtrlmsaRestart table
1.3.6.1.4.1.20044.107.6.3.210.1.2Columnpm100gemuxsfpCtrlmsaRestartPortnread-writecurrentLine MSA Restart :This OID tentatively restart the MSA line module <Help > This control initiates a restart of the MSA
1.3.6.1.4.1.20044.107.6.3.221Tablepm100gemuxsfpCtrlforceKeyExchangeTablenot-accessibledeprecatedList of pm100gemuxsfpCtrlforceKeyExchange Article
1.3.6.1.4.1.20044.107.6.3.221.1Rowpm100gemuxsfpCtrlforceKeyExchangeEntrynot-accessibledeprecatedRow definition for the pm100gemuxsfpCtrlforceKeyExchange table
1.3.6.1.4.1.20044.107.6.3.221.1.1Columnpm100gemuxsfpCtrlforceKeyExchangeIndexread-onlydeprecatedIndex definition for the pm100gemuxsfpCtrlforceKeyExchange table
1.3.6.1.4.1.20044.107.6.3.221.1.2Columnpm100gemuxsfpCtrlforceKeyExchangePortnread-writedeprecated:
1.3.6.1.4.1.20044.107.6.3.222Tablepm100gemuxsfpCtrldisableEncryptionTablenot-accessibledeprecatedList of pm100gemuxsfpCtrldisableEncryption Article
1.3.6.1.4.1.20044.107.6.3.222.1Rowpm100gemuxsfpCtrldisableEncryptionEntrynot-accessibledeprecatedRow definition for the pm100gemuxsfpCtrldisableEncryption table
1.3.6.1.4.1.20044.107.6.3.222.1.1Columnpm100gemuxsfpCtrldisableEncryptionIndexread-onlydeprecatedIndex definition for the pm100gemuxsfpCtrldisableEncryption table
1.3.6.1.4.1.20044.107.6.3.222.1.2Columnpm100gemuxsfpCtrldisableEncryptionPortnread-writedeprecated:
1.3.6.1.4.1.20044.107.6.3.223Tablepm100gemuxsfpCtrlresetMonitoringTablenot-accessibledeprecatedList of pm100gemuxsfpCtrlresetMonitoring Article
1.3.6.1.4.1.20044.107.6.3.223.1Rowpm100gemuxsfpCtrlresetMonitoringEntrynot-accessibledeprecatedRow definition for the pm100gemuxsfpCtrlresetMonitoring table
1.3.6.1.4.1.20044.107.6.3.223.1.1Columnpm100gemuxsfpCtrlresetMonitoringIndexread-onlydeprecatedIndex definition for the pm100gemuxsfpCtrlresetMonitoring table
1.3.6.1.4.1.20044.107.6.3.223.1.2Columnpm100gemuxsfpCtrlresetMonitoringPortnread-writedeprecated:
1.3.6.1.4.1.20044.107.6.3.263Tablepm100gemuxsfpCtrllineResetAllCountTablenot-accessiblecurrentList of pm100gemuxsfpCtrllineResetAllCount Article
1.3.6.1.4.1.20044.107.6.3.263.1Rowpm100gemuxsfpCtrllineResetAllCountEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpCtrllineResetAllCount table
1.3.6.1.4.1.20044.107.6.3.263.1.1Columnpm100gemuxsfpCtrllineResetAllCountIndexread-onlycurrentIndex definition for the pm100gemuxsfpCtrllineResetAllCount table
1.3.6.1.4.1.20044.107.6.3.263.1.2Columnpm100gemuxsfpCtrllineResetAllCountsPortnread-writecurrentLine Counters Reset :This OID resets every counter on the line port <Help> This control operates a reset on the statistics current ,previous and history line p…
1.3.6.1.4.1.20044.107.7Nodepm100gemuxsfpri
1.3.6.1.4.1.20044.107.7.1Nodepm100gemuxsfpriTable
1.3.6.1.4.1.20044.107.7.1.1Tablepm100gemuxsfpRinvSfpTablenot-accessiblecurrentList of the SFPs on the selected module
1.3.6.1.4.1.20044.107.7.1.1.1Rowpm100gemuxsfpRinvSfpEntrynot-accessiblecurrentRow definition for the SFP table
1.3.6.1.4.1.20044.107.7.1.1.1.1Columnpm100gemuxsfpRinvSfpIndexread-onlycurrentIndex for SFP table
1.3.6.1.4.1.20044.107.7.1.1.1.2Columnpm100gemuxsfpRinvsfpread-onlycurrentInventory for the SFP: This OID contains the inventory for the SFP
1.3.6.1.4.1.20044.107.7.1.2Tablepm100gemuxsfpRinvLineTablenot-accessiblecurrentList of the XFPs on the selected module
1.3.6.1.4.1.20044.107.7.1.2.1Rowpm100gemuxsfpRinvLineEntrynot-accessiblecurrentRow definition for the XFP table
1.3.6.1.4.1.20044.107.7.1.2.1.1Columnpm100gemuxsfpRinvLineIndexread-onlycurrentIndex for XFP table
1.3.6.1.4.1.20044.107.7.1.2.1.2Columnpm100gemuxsfpRinvxfpLineread-onlycurrentInventory for the XFP: This OID contains the inventory for the XFP
1.3.6.1.4.1.20044.107.7.2Scalarpm100gemuxsfpRinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.107.7.3Scalarpm100gemuxsfpRinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.107.7.4Scalarpm100gemuxsfpRinvModulePlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.107.7.5Scalarpm100gemuxsfpRinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.107.7.6Scalarpm100gemuxsfpRinvGwPlatformread-onlycurrentGW platform description: This OID contains the description of the Gateware platform.
1.3.6.1.4.1.20044.107.8Nodepm100gemuxsfpdownload
1.3.6.1.4.1.20044.107.8.1Nodepm100gemuxsfpDwlOther
1.3.6.1.4.1.20044.107.8.1.0Nodepm100gemuxsfpDwlrestartProcess
1.3.6.1.4.1.20044.107.8.1.0.1Scalarpm100gemuxsfpDwlWarmRestartProcessedread-onlycurrentWarm Restart :This OID indicates that the module last restart was a Warm RESTART
1.3.6.1.4.1.20044.107.8.1.0.2Scalarpm100gemuxsfpDwlColdRestartProcessedread-onlycurrentCold Restart :This OID indicates that the module last restart was a Cold RESTART
1.3.6.1.4.1.20044.107.8.1.1Nodepm100gemuxsfpDwlswBanksUsed
1.3.6.1.4.1.20044.107.8.1.1.1Scalarpm100gemuxsfpDwlSwBank1Usedread-onlycurrentSW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby
1.3.6.1.4.1.20044.107.8.1.1.2Scalarpm100gemuxsfpDwlSwBank2Usedread-onlycurrentSW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby
1.3.6.1.4.1.20044.107.8.1.1.5Scalarpm100gemuxsfpDwlSwBank1Notemptyread-onlycurrentSW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package
1.3.6.1.4.1.20044.107.8.1.1.6Scalarpm100gemuxsfpDwlSwBank2Notemptyread-onlycurrentSW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package
1.3.6.1.4.1.20044.107.8.1.2Nodepm100gemuxsfpDwlgwBanksUsed
1.3.6.1.4.1.20044.107.8.1.2.1Scalarpm100gemuxsfpDwlGwBank1Usedread-onlycurrentGW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby
1.3.6.1.4.1.20044.107.8.1.2.2Scalarpm100gemuxsfpDwlGwBank2Usedread-onlycurrentGW bank 2 active :This OID indicates the module is working on GW bank 2
1.3.6.1.4.1.20044.107.8.1.2.3Scalarpm100gemuxsfpDwlGwBank3Usedread-onlycurrentGW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby
1.3.6.1.4.1.20044.107.8.1.2.4Scalarpm100gemuxsfpDwlGwBank4Usedread-onlycurrentGW bank 4 active :This OID indicates the module is working on GW bank 4
1.3.6.1.4.1.20044.107.8.1.2.5Scalarpm100gemuxsfpDwlGwBank1Notemptyread-onlycurrentGW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package
1.3.6.1.4.1.20044.107.8.1.2.6Scalarpm100gemuxsfpDwlGwBank2Notemptyread-onlycurrentGW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2
1.3.6.1.4.1.20044.107.8.1.2.7Scalarpm100gemuxsfpDwlGwBank3Notemptyread-onlycurrentGW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package
1.3.6.1.4.1.20044.107.8.1.2.8Scalarpm100gemuxsfpDwlGwBank4Notemptyread-onlycurrentGW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4
1.3.6.1.4.1.20044.107.8.2Nodepm100gemuxsfpDwlClient
1.3.6.1.4.1.20044.107.8.3Nodepm100gemuxsfpDwlLine
1.3.6.1.4.1.20044.107.9Nodepm100gemuxsfpConfig
1.3.6.1.4.1.20044.107.9.1Nodepm100gemuxsfpCfgAccessCAisCsf
1.3.6.1.4.1.20044.107.9.1.1Tablepm100gemuxsfpCfgClientcaiscsfTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.107.9.1.1.1Rowpm100gemuxsfpCfgClientcaiscsfEntrynot-accessiblecurrentRow definition for the accessCAisCsf table
1.3.6.1.4.1.20044.107.9.1.1.1.1Columnpm100gemuxsfpCfgClientcaiscsfIndexread-onlycurrentIndex definition for the clientcaiscsf table
1.3.6.1.4.1.20044.107.9.1.1.1.3Columnpm100gemuxsfpCfgReservePortnread-writecurrentCAIS mode on Client Port :This register enables/disables port laser shutdown on CAIS insertion condition
1.3.6.1.4.1.20044.107.9.2Nodepm100gemuxsfpCfgStartup
1.3.6.1.4.1.20044.107.9.2.1Tablepm100gemuxsfpCfgClientStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.107.9.2.1.1Rowpm100gemuxsfpCfgClientStartupEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.107.9.2.1.1.1Columnpm100gemuxsfpCfgClientStartupIndexread-onlycurrentIndex definition for the clientStartup table
1.3.6.1.4.1.20044.107.9.2.1.1.3Columnpm100gemuxsfpCfgSystConfPortPortnread-writecurrentDefault Settings on Client Port :This register configures the default initialisation settings on the port.
1.3.6.1.4.1.20044.107.9.2.1.1.4Columnpm100gemuxsfpCfgNetConfPortPortnread-writecurrentDefault Settings on Client Port :This register configures the default initialisation settings on the port.
1.3.6.1.4.1.20044.107.9.2.1.1.14Columnpm100gemuxsfpCfgOptionsPortPortnread-writecurrentDefault Options on Client Port :This register configures the default options on the port.
1.3.6.1.4.1.20044.107.9.2.2Tablepm100gemuxsfpCfgLineStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.107.9.2.2.1Rowpm100gemuxsfpCfgLineStartupEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.107.9.2.2.1.1Columnpm100gemuxsfpCfgLineStartupIndexread-onlycurrentIndex definition for the lineStartup table
1.3.6.1.4.1.20044.107.9.2.2.1.3Columnpm100gemuxsfpCfgSystConfLinePortnread-writecurrentDefault Settings on Line :This register configures the default initialisation settings on Line
1.3.6.1.4.1.20044.107.9.2.2.1.14Columnpm100gemuxsfpCfgOptionsLinePortnread-writecurrentDefault Options on Line :This register configures the default options on the line
1.3.6.1.4.1.20044.107.9.2.3Tablepm100gemuxsfpCfgXfpTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.107.9.2.3.1Rowpm100gemuxsfpCfgXfpEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.107.9.2.3.1.1Columnpm100gemuxsfpCfgXfpIndexread-onlycurrentIndex definition for the xfp table
1.3.6.1.4.1.20044.107.9.2.3.1.3Columnpm100gemuxsfpCfgSystConfMsaLinePortnread-writecurrentDefault settings on TRX :This register configures the default initialisation settings on TRX
1.3.6.1.4.1.20044.107.9.2.3.1.6Columnpm100gemuxsfpCfgLineInputPowerHighAlarmPortnread-writedeprecatedDefault settings on alarm threshold :This register configures the default initialisation settings on a threshold
1.3.6.1.4.1.20044.107.9.2.3.1.7Columnpm100gemuxsfpCfgLineInputPowerHighWarningPortnread-writedeprecatedDefault settings on warning threshold :This register configures the default initialisation settings on a threshold
1.3.6.1.4.1.20044.107.9.2.3.1.8Columnpm100gemuxsfpCfgLineInputPowerLowWarningPortnread-writedeprecatedDefault settings on warning threshold :This register configures the default initialisation settings on a threshold
1.3.6.1.4.1.20044.107.9.2.3.1.9Columnpm100gemuxsfpCfgLineInputPowerLowAlarmPortnread-writedeprecatedDefault settings on alarm threshold :This register configures the default initialisation settings on a threshold
1.3.6.1.4.1.20044.107.9.2.3.1.10Columnpm100gemuxsfpCfgLineOutputPowerHighAlarmPortnread-writedeprecatedDefault settings on alarm threshold :This register configures the default initialisation settings on a threshold
1.3.6.1.4.1.20044.107.9.2.3.1.11Columnpm100gemuxsfpCfgLineOutputPowerHighWarningPortnread-writedeprecatedDefault settings on warning threshold :This register configures the default initialisation settings on a threshold
1.3.6.1.4.1.20044.107.9.2.3.1.12Columnpm100gemuxsfpCfgLineOutputPowerLowWarningPortnread-writedeprecatedDefault settings on warning threshold :This register configures the default initialisation settings on a threshold
1.3.6.1.4.1.20044.107.9.2.3.1.13Columnpm100gemuxsfpCfgLineOutputPowerLowAlarmPortnread-writedeprecatedDefault settings on alarm threshold :This register configures the default initialisation settings on a threshold
1.3.6.1.4.1.20044.107.9.2.3.1.14Columnpm100gemuxsfpCfgLineLossOfSignalPortnread-writedeprecatedDefault settings on Los threshold :This register configures the default initialisation settings on a threshold
1.3.6.1.4.1.20044.107.9.2.4Tablepm100gemuxsfpCfgClientOtxtlhTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.107.9.2.4.1Rowpm100gemuxsfpCfgClientOtxtlhEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.107.9.2.4.1.1Columnpm100gemuxsfpCfgClientOtxtlhIndexread-onlycurrentIndex definition for the clientOtxtlh table
1.3.6.1.4.1.20044.107.9.2.4.1.3Columnpm100gemuxsfpCfgControlsPortnread-writedeprecatedDefaut Client settings :This register configures the start-up settings on the ports
1.3.6.1.4.1.20044.107.9.2.4.1.6Columnpm100gemuxsfpCfgClientPwrLaserPortnread-writecurrentDefaut Client output Power :This register configures the start-up output power of the client transceiver (Unit = dBm)
1.3.6.1.4.1.20044.107.9.2.4.1.7Columnpm100gemuxsfpCfgClientFCurrentPortnread-writecurrentDefault Client transceiver Channel :This register configures the start-up laser channel of the client transceiver
1.3.6.1.4.1.20044.107.9.2.4.1.8Columnpm100gemuxsfpCfgClientGridCurrentPortnread-writecurrentDefault Client transceiver Grid :This register configures the start-up laser grid of the client transceiver
1.3.6.1.4.1.20044.107.9.2.4.1.9Columnpm100gemuxsfpCfgClientFoPortnread-writecurrentDefault Client first Frequency :This register configures the start-up first frequency of the client transceiver
1.3.6.1.4.1.20044.107.9.3Nodepm100gemuxsfpCfgLabels
1.3.6.1.4.1.20044.107.9.3.1Tablepm100gemuxsfpCfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.107.9.3.1.1Rowpm100gemuxsfpCfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.107.9.3.1.1.1Columnpm100gemuxsfpCfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.107.9.3.1.1.3Columnpm100gemuxsfpCfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.107.9.3.2Tablepm100gemuxsfpCfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.107.9.3.2.1Rowpm100gemuxsfpCfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.107.9.3.2.1.1Columnpm100gemuxsfpCfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.107.9.3.2.1.3Columnpm100gemuxsfpCfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.107.9.4Nodepm100gemuxsfpCfgStartuptlh
1.3.6.1.4.1.20044.107.9.4.1Tablepm100gemuxsfpCfgOtxtlhTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.107.9.4.1.1Rowpm100gemuxsfpCfgOtxtlhEntrynot-accessiblecurrentRow definition for the startuptlh table
1.3.6.1.4.1.20044.107.9.4.1.1.1Columnpm100gemuxsfpCfgOtxtlhIndexread-onlycurrentIndex definition for the otxtlh table
1.3.6.1.4.1.20044.107.9.4.1.1.6Columnpm100gemuxsfpCfgLinePwrLaserPortnread-writedeprecatedDefaut Line output Power :This register configures the start-up output power of the Line tranceiver (Unit = dBm)
1.3.6.1.4.1.20044.107.9.4.1.1.7Columnpm100gemuxsfpCfgLineFCurrentPortnread-writedeprecatedDefault Line transceiver Tx Channel :This register configures the start-up laser channel of the Line Tx transceiver
1.3.6.1.4.1.20044.107.9.4.1.1.8Columnpm100gemuxsfpCfgLineGridCurrentPortnread-writedeprecatedDefault Line transceiver Grid :This register configures the start-up laser grid of the Line transceiver
1.3.6.1.4.1.20044.107.9.4.1.1.9Columnpm100gemuxsfpCfgFPortnread-writedeprecatedDefault Line TRX lowest Freq :This register configures the start-up lowest frequency of the Line transceiver
1.3.6.1.4.1.20044.107.9.4.1.1.10Columnpm100gemuxsfpCfgRxLineFCurrentPortnread-writedeprecatedDefault Line transceiver Rx Channel :This register configures the start-up laser channel of the Line Rx transceiver
1.3.6.1.4.1.20044.107.9.5Nodepm100gemuxsfpCfgOther
1.3.6.1.4.1.20044.107.9.5.1Nodepm100gemuxsfptablemoduleOther
1.3.6.1.4.1.20044.107.9.5.1.5Scalarpm100gemuxsfpCfgmoduleModeread-writecurrentDefault settings on Module :This register selects the configuration mode of the module
1.3.6.1.4.1.20044.107.9.6Nodepm100gemuxsfpCfgStartuptablefive
1.3.6.1.4.1.20044.107.9.6.1Tablepm100gemuxsfpCfgOtxtlhcapabilitiesTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.107.9.6.1.1Rowpm100gemuxsfpCfgOtxtlhcapabilitiesEntrynot-accessiblecurrentRow definition for the startuptablefive table
1.3.6.1.4.1.20044.107.9.6.1.1.1Columnpm100gemuxsfpCfgOtxtlhcapabilitiesIndexread-onlycurrentIndex definition for the otxtlhcapabilities table
1.3.6.1.4.1.20044.107.9.6.1.1.3Columnpm100gemuxsfpCfgComponentTypePortnread-onlycurrentComponent parameters :This OID defines the component parameters
1.3.6.1.4.1.20044.107.9.6.1.1.4Columnpm100gemuxsfpCfgMiscellaneousPortnread-onlycurrentMiscellaneous default settings :This OID defines the miscellaneous parameters
1.3.6.1.4.1.20044.107.9.6.1.1.5Columnpm100gemuxsfpCfgFirstChannelPortnread-onlycurrentNumber of the first channel of the component :This OID defines the first channel number of the PM
1.3.6.1.4.1.20044.107.9.6.1.1.6Columnpm100gemuxsfpCfgLastChannelPortnread-onlycurrentNumber of the last channel of the component :This OID defines the last channel number of the PM
1.3.6.1.4.1.20044.107.9.6.1.1.7Columnpm100gemuxsfpCfgGridPortnread-onlycurrentGrid value of the component :This OID defines the grid of the PM
1.3.6.1.4.1.20044.107.9.257Scalarpm100gemuxsfpCfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.107.10Nodepm100gemuxsfptraps
1.3.6.1.4.1.20044.107.10.2Scalarpm100gemuxsfptrapPortNumberread-onlycurrentLast port which generates a trap
1.3.6.1.4.1.20044.107.10.3Scalarpm100gemuxsfptrapLineNumberread-onlycurrentLast Line which generates a trap
1.3.6.1.4.1.20044.107.10.4Scalarpm100gemuxsfptrapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.107.10.30Notificationpm100gemuxsfpLineTrapNotUrgentGoesOncurrentNot urgent Line default is activated
1.3.6.1.4.1.20044.107.10.31Notificationpm100gemuxsfpLineTrapNotUrgentGoesOffcurrentNot urgent Line default disappeared
1.3.6.1.4.1.20044.107.10.32Notificationpm100gemuxsfpLineTrapUrgentGoesOncurrentUrgent Line default is activated
1.3.6.1.4.1.20044.107.10.33Notificationpm100gemuxsfpLineTrapUrgentGoesOffcurrentUrgent Line default disappeared
1.3.6.1.4.1.20044.107.10.34Notificationpm100gemuxsfpLineTrapCritGoesOncurrentCritical Line default is activated
1.3.6.1.4.1.20044.107.10.35Notificationpm100gemuxsfpLineTrapCritGoesOffcurrentCritical Line default disappeared
1.3.6.1.4.1.20044.107.10.40Notificationpm100gemuxsfpClientTrapNotUrgentGoesOncurrentNot urgent client default is activated
1.3.6.1.4.1.20044.107.10.41Notificationpm100gemuxsfpClientTrapNotUrgentGoesOffcurrentNot urgent client default disappeared
1.3.6.1.4.1.20044.107.10.42Notificationpm100gemuxsfpClientTrapUrgentGoesOncurrentUrgent client default is activated
1.3.6.1.4.1.20044.107.10.43Notificationpm100gemuxsfpClientTrapUrgentGoesOffcurrentUrgent client default disappeared
1.3.6.1.4.1.20044.107.10.44Notificationpm100gemuxsfpClientTrapCritGoesOncurrentCritical client default is activated
1.3.6.1.4.1.20044.107.10.45Notificationpm100gemuxsfpClientTrapCritGoesOffcurrentCritical client default disappeared
1.3.6.1.4.1.20044.107.10.50Notificationpm100gemuxsfpPowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.107.10.51Notificationpm100gemuxsfpPowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared
1.3.6.1.4.1.20044.107.11Nodepm100gemuxsfpMonitoring
1.3.6.1.4.1.20044.107.11.1Nodepm100gemuxsfpMonOther
1.3.6.1.4.1.20044.107.11.1.3Nodepm100gemuxsfpMonRmon
1.3.6.1.4.1.20044.107.11.2Nodepm100gemuxsfpMonClient
1.3.6.1.4.1.20044.107.11.2.4Nodepm100gemuxsfpMonClientRmonCounter
1.3.6.1.4.1.20044.107.11.2.4.16Tablepm100gemuxsfpMonupRmonBytesCounterClientInputTablenot-accessiblecurrentList of pm100gemuxsfpMonupRmonBytesCounterClientInput Article
1.3.6.1.4.1.20044.107.11.2.4.16.1Rowpm100gemuxsfpMonupRmonBytesCounterClientInputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMonupRmonBytesCounterClientInput table
1.3.6.1.4.1.20044.107.11.2.4.16.1.1Columnpm100gemuxsfpMonupRmonBytesCounterClientInputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMonupRmonBytesCounterClientInput table
1.3.6.1.4.1.20044.107.11.2.4.16.1.2Columnpm100gemuxsfpMonupRmonBytesCounterClientInputValuePortnread-onlycurrentClient Input Bytes :This counter is increased each time a data byte is received on the client port <Help> This counter gives the number of bytes received on th…
1.3.6.1.4.1.20044.107.11.2.4.16.1.3Columnpm100gemuxsfpMonupRmonBytesCounterClientInputErrorPortnread-onlycurrentBytes Counter Error :This OID when set indicates the Bytes counter value is invalid on client port
1.3.6.1.4.1.20044.107.11.2.4.16.1.4Columnpm100gemuxsfpMonupRmonBytesCounterClientInputOverloadPortnread-onlycurrentBytes Counter Overload :This OID when set indicates a Bytes counter overload on client port
1.3.6.1.4.1.20044.107.11.2.4.48Tablepm100gemuxsfpMonupRmonCrcErrorsCounterClientInputTablenot-accessiblecurrentList of pm100gemuxsfpMonupRmonCrcErrorsCounterClientInput Article
1.3.6.1.4.1.20044.107.11.2.4.48.1Rowpm100gemuxsfpMonupRmonCrcErrorsCounterClientInputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMonupRmonCrcErrorsCounterClientInput table
1.3.6.1.4.1.20044.107.11.2.4.48.1.1Columnpm100gemuxsfpMonupRmonCrcErrorsCounterClientInputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMonupRmonCrcErrorsCounterClientInput table
1.3.6.1.4.1.20044.107.11.2.4.48.1.2Columnpm100gemuxsfpMonupRmonCrcErrorsCounterClientInputValuePortnread-onlycurrentClient Input CRC Errors :This counter is increased each time a CRC error is detected on the client port<Help> This counter gives the number of CRC Errors recei…
1.3.6.1.4.1.20044.107.11.2.4.48.1.3Columnpm100gemuxsfpMonupRmonCrcErrorsCounterClientInputErrorPortnread-onlycurrentCRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on client port
1.3.6.1.4.1.20044.107.11.2.4.48.1.4Columnpm100gemuxsfpMonupRmonCrcErrorsCounterClientInputOverloadPortnread-onlycurrentCRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on client port
1.3.6.1.4.1.20044.107.11.2.4.80Tablepm100gemuxsfpMonupRmonPacketsCounterClientInputTablenot-accessiblecurrentList of pm100gemuxsfpMonupRmonPacketsCounterClientInput Article
1.3.6.1.4.1.20044.107.11.2.4.80.1Rowpm100gemuxsfpMonupRmonPacketsCounterClientInputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMonupRmonPacketsCounterClientInput table
1.3.6.1.4.1.20044.107.11.2.4.80.1.1Columnpm100gemuxsfpMonupRmonPacketsCounterClientInputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMonupRmonPacketsCounterClientInput table
1.3.6.1.4.1.20044.107.11.2.4.80.1.2Columnpm100gemuxsfpMonupRmonPacketsCounterClientInputValuePortnread-onlycurrentClient Input Packets :This counter is increased each time a packet is received on the client port <Help> This counter gives the number of packets received on t…
1.3.6.1.4.1.20044.107.11.2.4.80.1.3Columnpm100gemuxsfpMonupRmonPacketsCounterClientInputErrorPortnread-onlycurrentPackets Counter Error :This OID when set indicates the Packets counter value is invalid on client port
1.3.6.1.4.1.20044.107.11.2.4.80.1.4Columnpm100gemuxsfpMonupRmonPacketsCounterClientInputOverloadPortnread-onlycurrentPackets Counter Overload :This OID when set indicates a Packets counter overload on client port
1.3.6.1.4.1.20044.107.11.2.4.112Tablepm100gemuxsfpMonupRmonBroadcastCounterClientInputTablenot-accessiblecurrentList of pm100gemuxsfpMonupRmonBroadcastCounterClientInput Article
1.3.6.1.4.1.20044.107.11.2.4.112.1Rowpm100gemuxsfpMonupRmonBroadcastCounterClientInputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMonupRmonBroadcastCounterClientInput table
1.3.6.1.4.1.20044.107.11.2.4.112.1.1Columnpm100gemuxsfpMonupRmonBroadcastCounterClientInputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMonupRmonBroadcastCounterClientInput table
1.3.6.1.4.1.20044.107.11.2.4.112.1.2Columnpm100gemuxsfpMonupRmonBroadcastCounterClientInputValuePortnread-onlycurrentClient Input Broadcast Packets :This counter is increased each time a broadcast packet is received on the client port <Help> This counter gives the number of B…
1.3.6.1.4.1.20044.107.11.2.4.112.1.3Columnpm100gemuxsfpMonupRmonBroadcastCounterClientInputErrorPortnread-onlycurrentBroadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on client port
1.3.6.1.4.1.20044.107.11.2.4.112.1.4Columnpm100gemuxsfpMonupRmonBroadcastCounterClientInputOverloadPortnread-onlycurrentBroadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port
1.3.6.1.4.1.20044.107.11.2.4.144Tablepm100gemuxsfpMonupRmonMulticastCounterClientInputTablenot-accessiblecurrentList of pm100gemuxsfpMonupRmonMulticastCounterClientInput Article
1.3.6.1.4.1.20044.107.11.2.4.144.1Rowpm100gemuxsfpMonupRmonMulticastCounterClientInputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMonupRmonMulticastCounterClientInput table
1.3.6.1.4.1.20044.107.11.2.4.144.1.1Columnpm100gemuxsfpMonupRmonMulticastCounterClientInputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMonupRmonMulticastCounterClientInput table
1.3.6.1.4.1.20044.107.11.2.4.144.1.2Columnpm100gemuxsfpMonupRmonMulticastCounterClientInputValuePortnread-onlycurrentClient Input Multicast Packets :This counter is increased each time a Multicast packet is received on the client port <Help> This counter gives the number of M…
1.3.6.1.4.1.20044.107.11.2.4.144.1.3Columnpm100gemuxsfpMonupRmonMulticastCounterClientInputErrorPortnread-onlycurrentMulticast Counter Error :This OID when set indicates the Multicast counter value is invalid on client port
1.3.6.1.4.1.20044.107.11.2.4.144.1.4Columnpm100gemuxsfpMonupRmonMulticastCounterClientInputOverloadPortnread-onlycurrentMulticast Counter Overload :This OID when set indicates a Multicast counter overload on client port
1.3.6.1.4.1.20044.107.11.2.4.176Tablepm100gemuxsfpMonupRmonPauseFrameCounterClientInputTablenot-accessiblecurrentList of pm100gemuxsfpMonupRmonPauseFrameCounterClientInput Article
1.3.6.1.4.1.20044.107.11.2.4.176.1Rowpm100gemuxsfpMonupRmonPauseFrameCounterClientInputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMonupRmonPauseFrameCounterClientInput table
1.3.6.1.4.1.20044.107.11.2.4.176.1.1Columnpm100gemuxsfpMonupRmonPauseFrameCounterClientInputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMonupRmonPauseFrameCounterClientInput table
1.3.6.1.4.1.20044.107.11.2.4.176.1.2Columnpm100gemuxsfpMonupRmonPauseFrameCounterClientInputValuePortnread-onlycurrentClient Input Pause Frames :This counter is increased each time a Pause frame is received on the client port <Help> This counter gives the number of Pause frame…
1.3.6.1.4.1.20044.107.11.2.4.176.1.3Columnpm100gemuxsfpMonupRmonPauseFrameCounterClientInputErrorPortnread-onlycurrentPause Counter Error :This OID when set indicates the Pause counter value is invalid on client port
1.3.6.1.4.1.20044.107.11.2.4.176.1.4Columnpm100gemuxsfpMonupRmonPauseFrameCounterClientInputOverloadPortnread-onlycurrentPause Counter Overload :This OID when set indicates a Pause counter overload on client port
1.3.6.1.4.1.20044.107.11.2.4.304Tablepm100gemuxsfpMonupRmonUnicastCounterClientInputTablenot-accessiblecurrentList of pm100gemuxsfpMonupRmonUnicastCounterClientInput Article
1.3.6.1.4.1.20044.107.11.2.4.304.1Rowpm100gemuxsfpMonupRmonUnicastCounterClientInputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMonupRmonUnicastCounterClientInput table
1.3.6.1.4.1.20044.107.11.2.4.304.1.1Columnpm100gemuxsfpMonupRmonUnicastCounterClientInputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMonupRmonUnicastCounterClientInput table
1.3.6.1.4.1.20044.107.11.2.4.304.1.2Columnpm100gemuxsfpMonupRmonUnicastCounterClientInputValuePortnread-onlycurrentClient Input Unicast Packets :This counter is increased each time a Unicast packet is received on the client port <Help> This counter gives the number of Unica…
1.3.6.1.4.1.20044.107.11.2.4.304.1.3Columnpm100gemuxsfpMonupRmonUnicastCounterClientInputErrorPortnread-onlycurrentUnicast Counter Error :This OID when set indicates the Unicast counter value is invalid on client port
1.3.6.1.4.1.20044.107.11.2.4.304.1.4Columnpm100gemuxsfpMonupRmonUnicastCounterClientInputOverloadPortnread-onlycurrentUnicast Counter Overload :This OID when set indicates a Unicast counter overload on client port
1.3.6.1.4.1.20044.107.11.2.4.336Tablepm100gemuxsfpMonupRmonNonunicastCounterClientInputTablenot-accessiblecurrentList of pm100gemuxsfpMonupRmonNonunicastCounterClientInput Article
1.3.6.1.4.1.20044.107.11.2.4.336.1Rowpm100gemuxsfpMonupRmonNonunicastCounterClientInputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMonupRmonNonunicastCounterClientInput table
1.3.6.1.4.1.20044.107.11.2.4.336.1.1Columnpm100gemuxsfpMonupRmonNonunicastCounterClientInputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMonupRmonNonunicastCounterClientInput table
1.3.6.1.4.1.20044.107.11.2.4.336.1.2Columnpm100gemuxsfpMonupRmonNonunicastCounterClientInputValuePortnread-onlycurrentClient Input Non Unicast Packets :This counter is increased each time a Non-Unicast packet is received on the client port <Help> This counter gives the number …
1.3.6.1.4.1.20044.107.11.2.4.336.1.3Columnpm100gemuxsfpMonupRmonNonunicastCounterClientInputErrorPortnread-onlycurrentNon Unicast Counter Error :This OID when set indicates the Non-Unicast counter value is invalid on client port
1.3.6.1.4.1.20044.107.11.2.4.336.1.4Columnpm100gemuxsfpMonupRmonNonunicastCounterClientInputOverloadPortnread-onlycurrentNon Unicast Counter Overload :This OID when set indicates a Non-Unicast counter overload on client port
1.3.6.1.4.1.20044.107.11.2.4.400Tablepm100gemuxsfpMondownRmonBytesCounterClientOutputTablenot-accessiblecurrentList of pm100gemuxsfpMondownRmonBytesCounterClientOutput Article
1.3.6.1.4.1.20044.107.11.2.4.400.1Rowpm100gemuxsfpMondownRmonBytesCounterClientOutputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMondownRmonBytesCounterClientOutput table
1.3.6.1.4.1.20044.107.11.2.4.400.1.1Columnpm100gemuxsfpMondownRmonBytesCounterClientOutputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMondownRmonBytesCounterClientOutput table
1.3.6.1.4.1.20044.107.11.2.4.400.1.2Columnpm100gemuxsfpMondownRmonBytesCounterClientOutputValuePortnread-onlycurrentClient Output Bytes :This counter is increased each time a data byte is transmitted on the client port <Help> This counter gives the number of bytes transmitte…
1.3.6.1.4.1.20044.107.11.2.4.400.1.3Columnpm100gemuxsfpMondownRmonBytesCounterClientOutputErrorPortnread-onlycurrentBytes Counter Error :This OID when set indicates the Bytes counter value is invalid on client port
1.3.6.1.4.1.20044.107.11.2.4.400.1.4Columnpm100gemuxsfpMondownRmonBytesCounterClientOutputOverloadPortnread-onlycurrentBytes Counter Overload :This OID when set indicates a Bytes counter overload on client port
1.3.6.1.4.1.20044.107.11.2.4.432Tablepm100gemuxsfpMondownRmonCrcErrorsCounterClientOutputTablenot-accessiblecurrentList of pm100gemuxsfpMondownRmonCrcErrorsCounterClientOutput Article
1.3.6.1.4.1.20044.107.11.2.4.432.1Rowpm100gemuxsfpMondownRmonCrcErrorsCounterClientOutputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMondownRmonCrcErrorsCounterClientOutput table
1.3.6.1.4.1.20044.107.11.2.4.432.1.1Columnpm100gemuxsfpMondownRmonCrcErrorsCounterClientOutputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMondownRmonCrcErrorsCounterClientOutput table
1.3.6.1.4.1.20044.107.11.2.4.432.1.2Columnpm100gemuxsfpMondownRmonCrcErrorsCounterClientOutputValuePortnread-onlycurrentClient Output CRC Errors :This counter is increased each time a CRC error is detected on the transmit client port <Help> This counter gives the number of CRC E…
1.3.6.1.4.1.20044.107.11.2.4.432.1.3Columnpm100gemuxsfpMondownRmonCrcErrorsCounterClientOutputErrorPortnread-onlycurrentCRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on client port
1.3.6.1.4.1.20044.107.11.2.4.432.1.4Columnpm100gemuxsfpMondownRmonCrcErrorsCounterClientOutputOverloadPortnread-onlycurrentCRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on client port
1.3.6.1.4.1.20044.107.11.2.4.464Tablepm100gemuxsfpMondownRmonPacketsCounterClientOutputTablenot-accessiblecurrentList of pm100gemuxsfpMondownRmonPacketsCounterClientOutput Article
1.3.6.1.4.1.20044.107.11.2.4.464.1Rowpm100gemuxsfpMondownRmonPacketsCounterClientOutputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMondownRmonPacketsCounterClientOutput table
1.3.6.1.4.1.20044.107.11.2.4.464.1.1Columnpm100gemuxsfpMondownRmonPacketsCounterClientOutputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMondownRmonPacketsCounterClientOutput table
1.3.6.1.4.1.20044.107.11.2.4.464.1.2Columnpm100gemuxsfpMondownRmonPacketsCounterClientOutputValuePortnread-onlycurrentClient Output Packets :This counter is increased each time a packet is transmitted on the client port <Help> This counter gives the number of packets transmitt…
1.3.6.1.4.1.20044.107.11.2.4.464.1.3Columnpm100gemuxsfpMondownRmonPacketsCounterClientOutputErrorPortnread-onlycurrentPackets Counter Error :This OID when set indicates the Packets counter value is invalid on client port
1.3.6.1.4.1.20044.107.11.2.4.464.1.4Columnpm100gemuxsfpMondownRmonPacketsCounterClientOutputOverloadPortnread-onlycurrentPackets Counter Overload :This OID when set indicates a Packets counter overload on client port
1.3.6.1.4.1.20044.107.11.2.4.496Tablepm100gemuxsfpMondownRmonBroadcastCounterClientOutputTablenot-accessiblecurrentList of pm100gemuxsfpMondownRmonBroadcastCounterClientOutput Article
1.3.6.1.4.1.20044.107.11.2.4.496.1Rowpm100gemuxsfpMondownRmonBroadcastCounterClientOutputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMondownRmonBroadcastCounterClientOutput table
1.3.6.1.4.1.20044.107.11.2.4.496.1.1Columnpm100gemuxsfpMondownRmonBroadcastCounterClientOutputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMondownRmonBroadcastCounterClientOutput table
1.3.6.1.4.1.20044.107.11.2.4.496.1.2Columnpm100gemuxsfpMondownRmonBroadcastCounterClientOutputValuePortnread-onlycurrentClient Output Broadcast Packets :This counter is increased each time a broadcast packet is transmitted on the client port <Help> This counter gives the number …
1.3.6.1.4.1.20044.107.11.2.4.496.1.3Columnpm100gemuxsfpMondownRmonBroadcastCounterClientOutputErrorPortnread-onlycurrentBroadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on client port
1.3.6.1.4.1.20044.107.11.2.4.496.1.4Columnpm100gemuxsfpMondownRmonBroadcastCounterClientOutputOverloadPortnread-onlycurrentBroadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port
1.3.6.1.4.1.20044.107.11.2.4.528Tablepm100gemuxsfpMondownRmonMulticastCounterClientOutputTablenot-accessiblecurrentList of pm100gemuxsfpMondownRmonMulticastCounterClientOutput Article
1.3.6.1.4.1.20044.107.11.2.4.528.1Rowpm100gemuxsfpMondownRmonMulticastCounterClientOutputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMondownRmonMulticastCounterClientOutput table
1.3.6.1.4.1.20044.107.11.2.4.528.1.1Columnpm100gemuxsfpMondownRmonMulticastCounterClientOutputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMondownRmonMulticastCounterClientOutput table
1.3.6.1.4.1.20044.107.11.2.4.528.1.2Columnpm100gemuxsfpMondownRmonMulticastCounterClientOutputValuePortnread-onlycurrentClient Output Multicast Packets :This counter is increased each time a Multicast packet is transmitted on the client port <Help> This counter gives the number …
1.3.6.1.4.1.20044.107.11.2.4.528.1.3Columnpm100gemuxsfpMondownRmonMulticastCounterClientOutputErrorPortnread-onlycurrentMulticast Counter Error :This OID when set indicates the Multicast counter value is invalid on client port
1.3.6.1.4.1.20044.107.11.2.4.528.1.4Columnpm100gemuxsfpMondownRmonMulticastCounterClientOutputOverloadPortnread-onlycurrentMulticast Counter Overload :This OID when set indicates a Multicast counter overload on client port
1.3.6.1.4.1.20044.107.11.2.4.560Tablepm100gemuxsfpMondownRmonPauseFrameCounterClientOutputTablenot-accessiblecurrentList of pm100gemuxsfpMondownRmonPauseFrameCounterClientOutput Article
1.3.6.1.4.1.20044.107.11.2.4.560.1Rowpm100gemuxsfpMondownRmonPauseFrameCounterClientOutputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMondownRmonPauseFrameCounterClientOutput table
1.3.6.1.4.1.20044.107.11.2.4.560.1.1Columnpm100gemuxsfpMondownRmonPauseFrameCounterClientOutputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMondownRmonPauseFrameCounterClientOutput table
1.3.6.1.4.1.20044.107.11.2.4.560.1.2Columnpm100gemuxsfpMondownRmonPauseFrameCounterClientOutputValuePortnread-onlycurrentClient Output Pause Frames :This counter is increased each time a Pause frame is transmitted on the client port <Help> This counter gives the number of Pause f…
1.3.6.1.4.1.20044.107.11.2.4.560.1.3Columnpm100gemuxsfpMondownRmonPauseFrameCounterClientOutputErrorPortnread-onlycurrentPause Counter Error :This OID when set indicates the Pause counter value is invalid on client port
1.3.6.1.4.1.20044.107.11.2.4.560.1.4Columnpm100gemuxsfpMondownRmonPauseFrameCounterClientOutputOverloadPortnread-onlycurrentPause Counter Overload :This OID when set indicates a Pause counter overload on client port
1.3.6.1.4.1.20044.107.11.2.4.688Tablepm100gemuxsfpMondownRmonUnicastCounterClientOutputTablenot-accessiblecurrentList of pm100gemuxsfpMondownRmonUnicastCounterClientOutput Article
1.3.6.1.4.1.20044.107.11.2.4.688.1Rowpm100gemuxsfpMondownRmonUnicastCounterClientOutputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMondownRmonUnicastCounterClientOutput table
1.3.6.1.4.1.20044.107.11.2.4.688.1.1Columnpm100gemuxsfpMondownRmonUnicastCounterClientOutputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMondownRmonUnicastCounterClientOutput table
1.3.6.1.4.1.20044.107.11.2.4.688.1.2Columnpm100gemuxsfpMondownRmonUnicastCounterClientOutputValuePortnread-onlycurrentClient Output Unicast Packets :This counter is increased each time a Unicast packet is transmitted on the client port <Help> This counter gives the number of U…
1.3.6.1.4.1.20044.107.11.2.4.688.1.3Columnpm100gemuxsfpMondownRmonUnicastCounterClientOutputErrorPortnread-onlycurrentUnicast Counter Error :This OID when set indicates the Unicast counter value is invalid on client port
1.3.6.1.4.1.20044.107.11.2.4.688.1.4Columnpm100gemuxsfpMondownRmonUnicastCounterClientOutputOverloadPortnread-onlycurrentUnicast Counter Overload :This OID when set indicates a Unicast counter overload on client port
1.3.6.1.4.1.20044.107.11.2.4.720Tablepm100gemuxsfpMondownRmonNonunicastCounterClientOutputTablenot-accessiblecurrentList of pm100gemuxsfpMondownRmonNonunicastCounterClientOutput Article
1.3.6.1.4.1.20044.107.11.2.4.720.1Rowpm100gemuxsfpMondownRmonNonunicastCounterClientOutputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMondownRmonNonunicastCounterClientOutput table
1.3.6.1.4.1.20044.107.11.2.4.720.1.1Columnpm100gemuxsfpMondownRmonNonunicastCounterClientOutputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMondownRmonNonunicastCounterClientOutput table
1.3.6.1.4.1.20044.107.11.2.4.720.1.2Columnpm100gemuxsfpMondownRmonNonunicastCounterClientOutputValuePortnread-onlycurrentClient Output Non Unicast Packets :This counter is increased each time a Non-Unicast packet is transmitted on the client port <Help> This counter gives the num…
1.3.6.1.4.1.20044.107.11.2.4.720.1.3Columnpm100gemuxsfpMondownRmonNonunicastCounterClientOutputErrorPortnread-onlycurrentNon Unicast Counter Error :This OID when set indicates the Non-Unicast counter value is invalid on client port
1.3.6.1.4.1.20044.107.11.2.4.720.1.4Columnpm100gemuxsfpMondownRmonNonunicastCounterClientOutputOverloadPortnread-onlycurrentNon Unicast Counter Overload :This OID when set indicates a Non-Unicast counter overload on client port
1.3.6.1.4.1.20044.107.11.3Nodepm100gemuxsfpMonLigne
1.3.6.1.4.1.20044.107.11.3.4Nodepm100gemuxsfpMonLineRmonCounter
1.3.6.1.4.1.20044.107.11.3.4.784Tablepm100gemuxsfpMonupRmonBytesCounterLineInputTablenot-accessiblecurrentList of pm100gemuxsfpMonupRmonBytesCounterLineInput Article
1.3.6.1.4.1.20044.107.11.3.4.784.1Rowpm100gemuxsfpMonupRmonBytesCounterLineInputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMonupRmonBytesCounterLineInput table
1.3.6.1.4.1.20044.107.11.3.4.784.1.1Columnpm100gemuxsfpMonupRmonBytesCounterLineInputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMonupRmonBytesCounterLineInput table
1.3.6.1.4.1.20044.107.11.3.4.784.1.2Columnpm100gemuxsfpMonupRmonBytesCounterLineInputValuePortnread-onlycurrentLine Input Bytes :This counter is increased each time a data byte is received on the Line port <Help> This counter gives the number of bytes received on the Li…
1.3.6.1.4.1.20044.107.11.3.4.784.1.3Columnpm100gemuxsfpMonupRmonBytesCounterLineInputErrorPortnread-onlycurrentBytes Counter Error :This OID when set indicates the Bytes counter value is invalid on Line port
1.3.6.1.4.1.20044.107.11.3.4.784.1.4Columnpm100gemuxsfpMonupRmonBytesCounterLineInputOverloadPortnread-onlycurrentBytes Counter Overload :This OID when set indicates a Bytes counter overload on Line port
1.3.6.1.4.1.20044.107.11.3.4.786Tablepm100gemuxsfpMonupRmonCrcErrorsCounterLineInputTablenot-accessiblecurrentList of pm100gemuxsfpMonupRmonCrcErrorsCounterLineInput Article
1.3.6.1.4.1.20044.107.11.3.4.786.1Rowpm100gemuxsfpMonupRmonCrcErrorsCounterLineInputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMonupRmonCrcErrorsCounterLineInput table
1.3.6.1.4.1.20044.107.11.3.4.786.1.1Columnpm100gemuxsfpMonupRmonCrcErrorsCounterLineInputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMonupRmonCrcErrorsCounterLineInput table
1.3.6.1.4.1.20044.107.11.3.4.786.1.2Columnpm100gemuxsfpMonupRmonCrcErrorsCounterLineInputValuePortnread-onlycurrentLine Input CRC Errors :This counter is increased each time a CRC error is detected on the Line port<Help> This counter gives the number of CRC Errors received …
1.3.6.1.4.1.20044.107.11.3.4.786.1.3Columnpm100gemuxsfpMonupRmonCrcErrorsCounterLineInputErrorPortnread-onlycurrentCRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on Line port
1.3.6.1.4.1.20044.107.11.3.4.786.1.4Columnpm100gemuxsfpMonupRmonCrcErrorsCounterLineInputOverloadPortnread-onlycurrentCRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on Line port
1.3.6.1.4.1.20044.107.11.3.4.788Tablepm100gemuxsfpMonupRmonPacketsCounterLineInputTablenot-accessiblecurrentList of pm100gemuxsfpMonupRmonPacketsCounterLineInput Article
1.3.6.1.4.1.20044.107.11.3.4.788.1Rowpm100gemuxsfpMonupRmonPacketsCounterLineInputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMonupRmonPacketsCounterLineInput table
1.3.6.1.4.1.20044.107.11.3.4.788.1.1Columnpm100gemuxsfpMonupRmonPacketsCounterLineInputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMonupRmonPacketsCounterLineInput table
1.3.6.1.4.1.20044.107.11.3.4.788.1.2Columnpm100gemuxsfpMonupRmonPacketsCounterLineInputValuePortnread-onlycurrentLine Input Packets :This counter is increased each time a packet is received on the Line port <Help> This counter gives the number of packets received on the L…
1.3.6.1.4.1.20044.107.11.3.4.788.1.3Columnpm100gemuxsfpMonupRmonPacketsCounterLineInputErrorPortnread-onlycurrentPackets Counter Error :This OID when set indicates the Packets counter value is invalid on Line port
1.3.6.1.4.1.20044.107.11.3.4.788.1.4Columnpm100gemuxsfpMonupRmonPacketsCounterLineInputOverloadPortnread-onlycurrentPackets Counter Overload :This OID when set indicates a Packets counter overload on Line port
1.3.6.1.4.1.20044.107.11.3.4.790Tablepm100gemuxsfpMonupRmonBroadcastCounterLineInputTablenot-accessiblecurrentList of pm100gemuxsfpMonupRmonBroadcastCounterLineInput Article
1.3.6.1.4.1.20044.107.11.3.4.790.1Rowpm100gemuxsfpMonupRmonBroadcastCounterLineInputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMonupRmonBroadcastCounterLineInput table
1.3.6.1.4.1.20044.107.11.3.4.790.1.1Columnpm100gemuxsfpMonupRmonBroadcastCounterLineInputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMonupRmonBroadcastCounterLineInput table
1.3.6.1.4.1.20044.107.11.3.4.790.1.2Columnpm100gemuxsfpMonupRmonBroadcastCounterLineInputValuePortnread-onlycurrentLine Input Broadcast Packets :This counter is increased each time a broadcast packet is received on the Line port <Help> This counter gives the number of Broad…
1.3.6.1.4.1.20044.107.11.3.4.790.1.3Columnpm100gemuxsfpMonupRmonBroadcastCounterLineInputErrorPortnread-onlycurrentBroadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on Line port
1.3.6.1.4.1.20044.107.11.3.4.790.1.4Columnpm100gemuxsfpMonupRmonBroadcastCounterLineInputOverloadPortnread-onlycurrentBroadcast Counter Overload :This OID when set indicates a Broadcast counter overload on Line port
1.3.6.1.4.1.20044.107.11.3.4.792Tablepm100gemuxsfpMonupRmonMulticastCounterLineInputTablenot-accessiblecurrentList of pm100gemuxsfpMonupRmonMulticastCounterLineInput Article
1.3.6.1.4.1.20044.107.11.3.4.792.1Rowpm100gemuxsfpMonupRmonMulticastCounterLineInputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMonupRmonMulticastCounterLineInput table
1.3.6.1.4.1.20044.107.11.3.4.792.1.1Columnpm100gemuxsfpMonupRmonMulticastCounterLineInputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMonupRmonMulticastCounterLineInput table
1.3.6.1.4.1.20044.107.11.3.4.792.1.2Columnpm100gemuxsfpMonupRmonMulticastCounterLineInputValuePortnread-onlycurrentLine Input Multicast Packets :This counter is increased each time a Multicast packet is received on the Line port <Help> This counter gives the number of Multi…
1.3.6.1.4.1.20044.107.11.3.4.792.1.3Columnpm100gemuxsfpMonupRmonMulticastCounterLineInputErrorPortnread-onlycurrentMulticast Counter Error :This OID when set indicates the Multicast counter value is invalid on Line port
1.3.6.1.4.1.20044.107.11.3.4.792.1.4Columnpm100gemuxsfpMonupRmonMulticastCounterLineInputOverloadPortnread-onlycurrentMulticast Counter Overload :This OID when set indicates a Multicast counter overload on Line port
1.3.6.1.4.1.20044.107.11.3.4.794Tablepm100gemuxsfpMonupRmonPauseFrameCounterLineInputTablenot-accessiblecurrentList of pm100gemuxsfpMonupRmonPauseFrameCounterLineInput Article
1.3.6.1.4.1.20044.107.11.3.4.794.1Rowpm100gemuxsfpMonupRmonPauseFrameCounterLineInputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMonupRmonPauseFrameCounterLineInput table
1.3.6.1.4.1.20044.107.11.3.4.794.1.1Columnpm100gemuxsfpMonupRmonPauseFrameCounterLineInputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMonupRmonPauseFrameCounterLineInput table
1.3.6.1.4.1.20044.107.11.3.4.794.1.2Columnpm100gemuxsfpMonupRmonPauseFrameCounterLineInputValuePortnread-onlycurrentLine Input Pause Frames :This counter is increased each time a Pause frame is received on the Line port <Help> This counter gives the number of Pause frames re…
1.3.6.1.4.1.20044.107.11.3.4.794.1.3Columnpm100gemuxsfpMonupRmonPauseFrameCounterLineInputErrorPortnread-onlycurrentPause Counter Error :This OID when set indicates the Pause counter value is invalid on Line port
1.3.6.1.4.1.20044.107.11.3.4.794.1.4Columnpm100gemuxsfpMonupRmonPauseFrameCounterLineInputOverloadPortnread-onlycurrentPause Counter Overload :This OID when set indicates a Pause counter overload on Line port
1.3.6.1.4.1.20044.107.11.3.4.796Tablepm100gemuxsfpMonupRmonUnicastCounterLineInputTablenot-accessiblecurrentList of pm100gemuxsfpMonupRmonUnicastCounterLineInput Article
1.3.6.1.4.1.20044.107.11.3.4.796.1Rowpm100gemuxsfpMonupRmonUnicastCounterLineInputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMonupRmonUnicastCounterLineInput table
1.3.6.1.4.1.20044.107.11.3.4.796.1.1Columnpm100gemuxsfpMonupRmonUnicastCounterLineInputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMonupRmonUnicastCounterLineInput table
1.3.6.1.4.1.20044.107.11.3.4.796.1.2Columnpm100gemuxsfpMonupRmonUnicastCounterLineInputValuePortnread-onlycurrentLine Input Unicast Packets :This counter is increased each time a Unicast packet is received on the Line port <Help> This counter gives the number of Unicast p…
1.3.6.1.4.1.20044.107.11.3.4.796.1.3Columnpm100gemuxsfpMonupRmonUnicastCounterLineInputErrorPortnread-onlycurrentUnicast Counter Error :This OID when set indicates the Unicast counter value is invalid on Line port
1.3.6.1.4.1.20044.107.11.3.4.796.1.4Columnpm100gemuxsfpMonupRmonUnicastCounterLineInputOverloadPortnread-onlycurrentUnicast Counter Overload :This OID when set indicates a Unicast counter overload on Line port
1.3.6.1.4.1.20044.107.11.3.4.798Tablepm100gemuxsfpMonupRmonNonunicastCounterLineInputTablenot-accessiblecurrentList of pm100gemuxsfpMonupRmonNonunicastCounterLineInput Article
1.3.6.1.4.1.20044.107.11.3.4.798.1Rowpm100gemuxsfpMonupRmonNonunicastCounterLineInputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMonupRmonNonunicastCounterLineInput table
1.3.6.1.4.1.20044.107.11.3.4.798.1.1Columnpm100gemuxsfpMonupRmonNonunicastCounterLineInputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMonupRmonNonunicastCounterLineInput table
1.3.6.1.4.1.20044.107.11.3.4.798.1.2Columnpm100gemuxsfpMonupRmonNonunicastCounterLineInputValuePortnread-onlycurrentLine Input Non Unicast Packets :This counter is increased each time a Non-Unicast packet is received on the Line port <Help> This counter gives the number of N…
1.3.6.1.4.1.20044.107.11.3.4.798.1.3Columnpm100gemuxsfpMonupRmonNonunicastCounterLineInputErrorPortnread-onlycurrentNon Unicast Counter Error :This OID when set indicates the Non-Unicast counter value is invalid on Line port
1.3.6.1.4.1.20044.107.11.3.4.798.1.4Columnpm100gemuxsfpMonupRmonNonunicastCounterLineInputOverloadPortnread-onlycurrentNon Unicast Counter Overload :This OID when set indicates a Non-Unicast counter overload on Line port
1.3.6.1.4.1.20044.107.11.3.4.800Tablepm100gemuxsfpMondownRmonBytesCounterLineOutputTablenot-accessiblecurrentList of pm100gemuxsfpMondownRmonBytesCounterLineOutput Article
1.3.6.1.4.1.20044.107.11.3.4.800.1Rowpm100gemuxsfpMondownRmonBytesCounterLineOutputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMondownRmonBytesCounterLineOutput table
1.3.6.1.4.1.20044.107.11.3.4.800.1.1Columnpm100gemuxsfpMondownRmonBytesCounterLineOutputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMondownRmonBytesCounterLineOutput table
1.3.6.1.4.1.20044.107.11.3.4.800.1.2Columnpm100gemuxsfpMondownRmonBytesCounterLineOutputValuePortnread-onlycurrentLine Output Bytes :This counter is increased each time a data byte is transmitted on the Line port <Help> This counter gives the number of bytes transmitted on…
1.3.6.1.4.1.20044.107.11.3.4.800.1.3Columnpm100gemuxsfpMondownRmonBytesCounterLineOutputErrorPortnread-onlycurrentBytes Counter Error :This OID when set indicates the Bytes counter value is invalid on Line port
1.3.6.1.4.1.20044.107.11.3.4.800.1.4Columnpm100gemuxsfpMondownRmonBytesCounterLineOutputOverloadPortnread-onlycurrentBytes Counter Overload :This OID when set indicates a Bytes counter overload on Line port
1.3.6.1.4.1.20044.107.11.3.4.802Tablepm100gemuxsfpMondownRmonCrcErrorsCounterLineOutputTablenot-accessiblecurrentList of pm100gemuxsfpMondownRmonCrcErrorsCounterLineOutput Article
1.3.6.1.4.1.20044.107.11.3.4.802.1Rowpm100gemuxsfpMondownRmonCrcErrorsCounterLineOutputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMondownRmonCrcErrorsCounterLineOutput table
1.3.6.1.4.1.20044.107.11.3.4.802.1.1Columnpm100gemuxsfpMondownRmonCrcErrorsCounterLineOutputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMondownRmonCrcErrorsCounterLineOutput table
1.3.6.1.4.1.20044.107.11.3.4.802.1.2Columnpm100gemuxsfpMondownRmonCrcErrorsCounterLineOutputValuePortnread-onlycurrentLine Output CRC Errors :This counter is increased each time a CRC error is detected on the transmit Line port <Help> This counter gives the number of CRC Error…
1.3.6.1.4.1.20044.107.11.3.4.802.1.3Columnpm100gemuxsfpMondownRmonCrcErrorsCounterLineOutputErrorPortnread-onlycurrentCRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on Line port
1.3.6.1.4.1.20044.107.11.3.4.802.1.4Columnpm100gemuxsfpMondownRmonCrcErrorsCounterLineOutputOverloadPortnread-onlycurrentCRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on Line port
1.3.6.1.4.1.20044.107.11.3.4.804Tablepm100gemuxsfpMondownRmonPacketsCounterLineOutputTablenot-accessiblecurrentList of pm100gemuxsfpMondownRmonPacketsCounterLineOutput Article
1.3.6.1.4.1.20044.107.11.3.4.804.1Rowpm100gemuxsfpMondownRmonPacketsCounterLineOutputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMondownRmonPacketsCounterLineOutput table
1.3.6.1.4.1.20044.107.11.3.4.804.1.1Columnpm100gemuxsfpMondownRmonPacketsCounterLineOutputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMondownRmonPacketsCounterLineOutput table
1.3.6.1.4.1.20044.107.11.3.4.804.1.2Columnpm100gemuxsfpMondownRmonPacketsCounterLineOutputValuePortnread-onlycurrentLine Output Packets :This counter is increased each time a packet is transmitted on the Line port <Help> This counter gives the number of packets transmitted o…
1.3.6.1.4.1.20044.107.11.3.4.804.1.3Columnpm100gemuxsfpMondownRmonPacketsCounterLineOutputErrorPortnread-onlycurrentPackets Counter Error :This OID when set indicates the Packets counter value is invalid on Line port
1.3.6.1.4.1.20044.107.11.3.4.804.1.4Columnpm100gemuxsfpMondownRmonPacketsCounterLineOutputOverloadPortnread-onlycurrentPackets Counter Overload :This OID when set indicates a Packets counter overload on Line port
1.3.6.1.4.1.20044.107.11.3.4.806Tablepm100gemuxsfpMondownRmonBroadcastCounterLineOutputTablenot-accessiblecurrentList of pm100gemuxsfpMondownRmonBroadcastCounterLineOutput Article
1.3.6.1.4.1.20044.107.11.3.4.806.1Rowpm100gemuxsfpMondownRmonBroadcastCounterLineOutputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMondownRmonBroadcastCounterLineOutput table
1.3.6.1.4.1.20044.107.11.3.4.806.1.1Columnpm100gemuxsfpMondownRmonBroadcastCounterLineOutputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMondownRmonBroadcastCounterLineOutput table
1.3.6.1.4.1.20044.107.11.3.4.806.1.2Columnpm100gemuxsfpMondownRmonBroadcastCounterLineOutputValuePortnread-onlycurrentLine Output Broadcast Packets :This counter is increased each time a broadcast packet is transmitted on the Line port <Help> This counter gives the number of B…
1.3.6.1.4.1.20044.107.11.3.4.806.1.3Columnpm100gemuxsfpMondownRmonBroadcastCounterLineOutputErrorPortnread-onlycurrentBroadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on Line port
1.3.6.1.4.1.20044.107.11.3.4.806.1.4Columnpm100gemuxsfpMondownRmonBroadcastCounterLineOutputOverloadPortnread-onlycurrentBroadcast Counter Overload :This OID when set indicates a Broadcast counter overload on Line port
1.3.6.1.4.1.20044.107.11.3.4.808Tablepm100gemuxsfpMondownRmonMulticastCounterLineOutputTablenot-accessiblecurrentList of pm100gemuxsfpMondownRmonMulticastCounterLineOutput Article
1.3.6.1.4.1.20044.107.11.3.4.808.1Rowpm100gemuxsfpMondownRmonMulticastCounterLineOutputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMondownRmonMulticastCounterLineOutput table
1.3.6.1.4.1.20044.107.11.3.4.808.1.1Columnpm100gemuxsfpMondownRmonMulticastCounterLineOutputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMondownRmonMulticastCounterLineOutput table
1.3.6.1.4.1.20044.107.11.3.4.808.1.2Columnpm100gemuxsfpMondownRmonMulticastCounterLineOutputValuePortnread-onlycurrentLine Output Multicast Packets :This counter is increased each time a Multicast packet is transmitted on the Line port <Help> This counter gives the number of M…
1.3.6.1.4.1.20044.107.11.3.4.808.1.3Columnpm100gemuxsfpMondownRmonMulticastCounterLineOutputErrorPortnread-onlycurrentMulticast Counter Error :This OID when set indicates the Multicast counter value is invalid on Line port
1.3.6.1.4.1.20044.107.11.3.4.808.1.4Columnpm100gemuxsfpMondownRmonMulticastCounterLineOutputOverloadPortnread-onlycurrentMulticast Counter Overload :This OID when set indicates a Multicast counter overload on Line port
1.3.6.1.4.1.20044.107.11.3.4.810Tablepm100gemuxsfpMondownRmonPauseFrameCounterLineOutputTablenot-accessiblecurrentList of pm100gemuxsfpMondownRmonPauseFrameCounterLineOutput Article
1.3.6.1.4.1.20044.107.11.3.4.810.1Rowpm100gemuxsfpMondownRmonPauseFrameCounterLineOutputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMondownRmonPauseFrameCounterLineOutput table
1.3.6.1.4.1.20044.107.11.3.4.810.1.1Columnpm100gemuxsfpMondownRmonPauseFrameCounterLineOutputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMondownRmonPauseFrameCounterLineOutput table
1.3.6.1.4.1.20044.107.11.3.4.810.1.2Columnpm100gemuxsfpMondownRmonPauseFrameCounterLineOutputValuePortnread-onlycurrentLine Output Pause Frames :This counter is increased each time a Pause frame is transmitted on the Line port <Help> This counter gives the number of Pause frame…
1.3.6.1.4.1.20044.107.11.3.4.810.1.3Columnpm100gemuxsfpMondownRmonPauseFrameCounterLineOutputErrorPortnread-onlycurrentPause Counter Error :This OID when set indicates the Pause counter value is invalid on Line port
1.3.6.1.4.1.20044.107.11.3.4.810.1.4Columnpm100gemuxsfpMondownRmonPauseFrameCounterLineOutputOverloadPortnread-onlycurrentPause Counter Overload :This OID when set indicates a Pause counter overload on Line port
1.3.6.1.4.1.20044.107.11.3.4.812Tablepm100gemuxsfpMondownRmonUnicastCounterLineOutputTablenot-accessiblecurrentList of pm100gemuxsfpMondownRmonUnicastCounterLineOutput Article
1.3.6.1.4.1.20044.107.11.3.4.812.1Rowpm100gemuxsfpMondownRmonUnicastCounterLineOutputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMondownRmonUnicastCounterLineOutput table
1.3.6.1.4.1.20044.107.11.3.4.812.1.1Columnpm100gemuxsfpMondownRmonUnicastCounterLineOutputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMondownRmonUnicastCounterLineOutput table
1.3.6.1.4.1.20044.107.11.3.4.812.1.2Columnpm100gemuxsfpMondownRmonUnicastCounterLineOutputValuePortnread-onlycurrentLine Output Unicast Packets :This counter is increased each time a Unicast packet is transmitted on the Line port <Help> This counter gives the number of Unica…
1.3.6.1.4.1.20044.107.11.3.4.812.1.3Columnpm100gemuxsfpMondownRmonUnicastCounterLineOutputErrorPortnread-onlycurrentUnicast Counter Error :This OID when set indicates the Unicast counter value is invalid on Line port
1.3.6.1.4.1.20044.107.11.3.4.812.1.4Columnpm100gemuxsfpMondownRmonUnicastCounterLineOutputOverloadPortnread-onlycurrentUnicast Counter Overload :This OID when set indicates a Unicast counter overload on Line port
1.3.6.1.4.1.20044.107.11.3.4.814Tablepm100gemuxsfpMondownRmonNonunicastCounterLineOutputTablenot-accessiblecurrentList of pm100gemuxsfpMondownRmonNonunicastCounterLineOutput Article
1.3.6.1.4.1.20044.107.11.3.4.814.1Rowpm100gemuxsfpMondownRmonNonunicastCounterLineOutputEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpMondownRmonNonunicastCounterLineOutput table
1.3.6.1.4.1.20044.107.11.3.4.814.1.1Columnpm100gemuxsfpMondownRmonNonunicastCounterLineOutputIndexread-onlycurrentIndex definition for the pm100gemuxsfpMondownRmonNonunicastCounterLineOutput table
1.3.6.1.4.1.20044.107.11.3.4.814.1.2Columnpm100gemuxsfpMondownRmonNonunicastCounterLineOutputValuePortnread-onlycurrentLine Output Non Unicast Packets :This counter is increased each time a Non-Unicast packet is transmitted on the Line port <Help> This counter gives the number …
1.3.6.1.4.1.20044.107.11.3.4.814.1.3Columnpm100gemuxsfpMondownRmonNonunicastCounterLineOutputErrorPortnread-onlycurrentNon Unicast Counter Error :This OID when set indicates the Non-Unicast counter value is invalid on Line port
1.3.6.1.4.1.20044.107.11.3.4.814.1.4Columnpm100gemuxsfpMondownRmonNonunicastCounterLineOutputOverloadPortnread-onlycurrentNon Unicast Counter Overload :This OID when set indicates a Non-Unicast counter overload on Line port
1.3.6.1.4.1.20044.107.11.5Nodepm100gemuxsfpMonPerfOther
1.3.6.1.4.1.20044.107.11.5.1Nodepm100gemuxsfpMonPerfSync
1.3.6.1.4.1.20044.107.11.5.1.257Scalarpm100gemuxsfpPerfEnableread-writecurrentPerf. Mon. Enable :This OID enables the Performance Monitoring application
1.3.6.1.4.1.20044.107.11.5.1.259Scalarpm100gemuxsfpPerf15minSyncread-writecurrentPerf. Mon. 15-min sync. :This OID must be used in external synchronisation mode only to send a 15-min synchronisation command
1.3.6.1.4.1.20044.107.11.5.1.260Scalarpm100gemuxsfpPerf24hSyncread-writecurrentPerf. Mon. 24-hours sync. :This OID must be used in external synchronisation mode only to send a 24-hours synchronisation command
1.3.6.1.4.1.20044.107.11.5.2Nodepm100gemuxsfpMonPerfTimeStamp
1.3.6.1.4.1.20044.107.11.5.2.1Scalarpm100gemuxsfpPerf15MinShortread-writecurrent15-min period is short :This OID indicates that the 15-min period lasts less than 890 seconds
1.3.6.1.4.1.20044.107.11.5.2.2Scalarpm100gemuxsfpPerf15MinLongread-writecurrent15-min period is long :This OID indicates that the 15-min period lasts more than 910 seconds
1.3.6.1.4.1.20044.107.11.5.2.5Scalarpm100gemuxsfpPerf24HoursShortread-writecurrent24-hours period is short :This OID indicates that 24-hours period lasts less than 86390 seconds
1.3.6.1.4.1.20044.107.11.5.2.6Scalarpm100gemuxsfpPerf24HoursLongread-writecurrent24-hours period is long :This OID indicates that 24-hours period lasts more than 86410 seconds
1.3.6.1.4.1.20044.107.11.5.2.7Scalarpm100gemuxsfpPerfCurrent15MinElapsedTimeread-writecurrentCurrent 15min period Elapsed Time :This OID gives the number of seconds elapsed in the current 15-minutes period
1.3.6.1.4.1.20044.107.11.5.2.8Scalarpm100gemuxsfpPerfCurrent24HoursElapsedTimeread-writecurrentCurrent 24hours period Elapsed Time :This OID gives the number of seconds elapsed in the current 24-hours period
1.3.6.1.4.1.20044.107.11.6Nodepm100gemuxsfpMonPerfClient
1.3.6.1.4.1.20044.107.11.6.16Tablepm100gemuxsfpPerfTelecomInputClientCurrent15StatTablenot-accessiblecurrentList of pm100gemuxsfpPerfTelecomInputClientCurrent15Stat Article
1.3.6.1.4.1.20044.107.11.6.16.1Rowpm100gemuxsfpPerfTelecomInputClientCurrent15StatEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpPerfTelecomInputClientCurrent15Stat table
1.3.6.1.4.1.20044.107.11.6.16.1.1Columnpm100gemuxsfpPerfTelecomInputClientCurrent15StatIndexread-onlycurrentIndex definition for the pm100gemuxsfpPerfTelecomInputClientCurrent15Stat table
1.3.6.1.4.1.20044.107.11.6.16.1.2Columnpm100gemuxsfpPerfTelecomInputClientCurrent15StatInvCvPortnread-onlycurrentCurrent 15-min EBC counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.107.11.6.16.1.3Columnpm100gemuxsfpPerfTelecomInputClientCurrent15StatCvValuePortnread-onlycurrentCurrent 15-min EBC counter :This OID gives the current 15-min Coding Violation counter value
1.3.6.1.4.1.20044.107.11.6.16.1.4Columnpm100gemuxsfpPerfTelecomInputClientCurrent15StatInvEsPortnread-onlycurrentCurrent 15-min ES counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.16.1.5Columnpm100gemuxsfpPerfTelecomInputClientCurrent15StatEsValuePortnread-onlycurrentCurrent 15-min ES counter :This OID gives the current 15-min Errored Second counter value
1.3.6.1.4.1.20044.107.11.6.16.1.6Columnpm100gemuxsfpPerfTelecomInputClientCurrent15StatInvSesPortnread-onlycurrentCurrent 15-min SES counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.16.1.7Columnpm100gemuxsfpPerfTelecomInputClientCurrent15StatSesValuePortnread-onlycurrentCurrent 15-min SES counter :This OID gives the current 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.107.11.6.16.1.8Columnpm100gemuxsfpPerfTelecomInputClientCurrent15StatInvSefsPortnread-onlycurrentCurrent 15-min SEFS counter inv. :This OID indicates that the current 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.16.1.9Columnpm100gemuxsfpPerfTelecomInputClientCurrent15StatSefsValuePortnread-onlycurrentCurrent 15-min SEFS counter :This OID gives the current 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.107.11.6.16.1.10Columnpm100gemuxsfpPerfTelecomInputClientCurrent15StatInvUasPortnread-onlycurrentCurrent 15-min UAS counter inv. :This OID indicates that the current 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.16.1.11Columnpm100gemuxsfpPerfTelecomInputClientCurrent15StatUasValuePortnread-onlycurrentCurrent 15-min UAS counter :This OID gives the current 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.107.11.6.48Tablepm100gemuxsfpPerfTelecomInputClientPast15StatHistoryPort1Tablenot-accessiblecurrentList of pm100gemuxsfpPerfTelecomInputClientPast15StatHistory Article
1.3.6.1.4.1.20044.107.11.6.48.1Rowpm100gemuxsfpPerfTelecomInputClientPast15StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pm100gemuxsfpPerfTelecomInputClientPast15StatHistory table
1.3.6.1.4.1.20044.107.11.6.48.1.1Columnpm100gemuxsfpPerfTelecomInputClientPast15StatHistoryPort1Indexread-onlycurrentIndex definition for the pm100gemuxsfpPerfTelecomInputClientPast15StatHistory table
1.3.6.1.4.1.20044.107.11.6.48.1.2Columnpm100gemuxsfpPerfTelecomInputClientPast15StatHistoryInvCvPort1read-onlycurrentPrevious 15-min EBC counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.107.11.6.48.1.3Columnpm100gemuxsfpPerfTelecomInputClientPast15StatHistoryCvValuePort1read-onlycurrentPrevious 15-min EBC counter :This OID gives the previous 15-min Coding Violation counter value
1.3.6.1.4.1.20044.107.11.6.48.1.4Columnpm100gemuxsfpPerfTelecomInputClientPast15StatHistoryInvEsPort1read-onlycurrentPrevious 15-min ES counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.48.1.5Columnpm100gemuxsfpPerfTelecomInputClientPast15StatHistoryEsValuePort1read-onlycurrentPrevious 15-min ES counter :This OID gives the previous 15-min Errored Second counter value
1.3.6.1.4.1.20044.107.11.6.48.1.6Columnpm100gemuxsfpPerfTelecomInputClientPast15StatHistoryInvSesPort1read-onlycurrentPrevious 15-min SES counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.48.1.7Columnpm100gemuxsfpPerfTelecomInputClientPast15StatHistorySesValuePort1read-onlycurrentPrevious 15-min SES counter :This OID gives the previous 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.107.11.6.48.1.8Columnpm100gemuxsfpPerfTelecomInputClientPast15StatHistoryInvSefsPort1read-onlycurrentPrevious 15-min SEFS counter inv. :This OID indicates that the previous 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.48.1.9Columnpm100gemuxsfpPerfTelecomInputClientPast15StatHistorySefsValuePort1read-onlycurrentPrevious 15-min SEFS counter :This OID gives the previous 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.107.11.6.48.1.10Columnpm100gemuxsfpPerfTelecomInputClientPast15StatHistoryInvUasPort1read-onlycurrentPrevious 15-min UAS counter inv. :This OID indicates that the previous 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.48.1.11Columnpm100gemuxsfpPerfTelecomInputClientPast15StatHistoryUasValuePort1read-onlycurrentPrevious 15-min UAS counter :This OID gives the previous 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.107.11.6.80Tablepm100gemuxsfpPerfTelecomInputClientCurrent24StatTablenot-accessiblecurrentList of pm100gemuxsfpPerfTelecomInputClientCurrent24Stat Article
1.3.6.1.4.1.20044.107.11.6.80.1Rowpm100gemuxsfpPerfTelecomInputClientCurrent24StatEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpPerfTelecomInputClientCurrent24Stat table
1.3.6.1.4.1.20044.107.11.6.80.1.1Columnpm100gemuxsfpPerfTelecomInputClientCurrent24StatIndexread-onlycurrentIndex definition for the pm100gemuxsfpPerfTelecomInputClientCurrent24Stat table
1.3.6.1.4.1.20044.107.11.6.80.1.2Columnpm100gemuxsfpPerfTelecomInputClientCurrent24StatInvCvPortnread-onlycurrentCurrent 24-hours EBC counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.107.11.6.80.1.3Columnpm100gemuxsfpPerfTelecomInputClientCurrent24StatCvValuePortnread-onlycurrentCurrent 24-hours EBC counter :This OID gives the current 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.107.11.6.80.1.4Columnpm100gemuxsfpPerfTelecomInputClientCurrent24StatInvEsPortnread-onlycurrentCurrent 24-hours ES counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.80.1.5Columnpm100gemuxsfpPerfTelecomInputClientCurrent24StatEsValuePortnread-onlycurrentCurrent 24-hours ES counter :This OID gives the current 24-hours Errored Second counter value
1.3.6.1.4.1.20044.107.11.6.80.1.6Columnpm100gemuxsfpPerfTelecomInputClientCurrent24StatInvSesPortnread-onlycurrentCurrent 24-hours SES counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.80.1.7Columnpm100gemuxsfpPerfTelecomInputClientCurrent24StatSesValuePortnread-onlycurrentCurrent 24-hours SES counter :This OID gives the current 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.107.11.6.80.1.8Columnpm100gemuxsfpPerfTelecomInputClientCurrent24StatInvSefsPortnread-onlycurrentCurrent 24-hours SEFS counter inv. :This OID indicates that the current 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.80.1.9Columnpm100gemuxsfpPerfTelecomInputClientCurrent24StatSefsValuePortnread-onlycurrentCurrent 24-hours SEFS counter :This OID gives the current 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.107.11.6.80.1.10Columnpm100gemuxsfpPerfTelecomInputClientCurrent24StatInvUasPortnread-onlycurrentCurrent 24-hours UAS counter inv. :This OID indicates that the current 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.80.1.11Columnpm100gemuxsfpPerfTelecomInputClientCurrent24StatUasValuePortnread-onlycurrentCurrent 24-hours UAS counter :This OID gives the current 24-hours UnAvailable Second counter value
1.3.6.1.4.1.20044.107.11.6.112Tablepm100gemuxsfpPerfTelecomInputClientPast24StatHistoryPort1Tablenot-accessiblecurrentList of pm100gemuxsfpPerfTelecomInputClientPast24StatHistory Article
1.3.6.1.4.1.20044.107.11.6.112.1Rowpm100gemuxsfpPerfTelecomInputClientPast24StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pm100gemuxsfpPerfTelecomInputClientPast24StatHistory table
1.3.6.1.4.1.20044.107.11.6.112.1.1Columnpm100gemuxsfpPerfTelecomInputClientPast24StatHistoryPort1Indexread-onlycurrentIndex definition for the pm100gemuxsfpPerfTelecomInputClientPast24StatHistory table
1.3.6.1.4.1.20044.107.11.6.112.1.2Columnpm100gemuxsfpPerfTelecomInputClientPast24StatHistoryInvCvPort1read-onlycurrentPrevious 24-hours EBC counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.107.11.6.112.1.3Columnpm100gemuxsfpPerfTelecomInputClientPast24StatHistoryCvValuePort1read-onlycurrentPrevious 24-hours EBC counter :This OID gives the previous 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.107.11.6.112.1.4Columnpm100gemuxsfpPerfTelecomInputClientPast24StatHistoryInvEsPort1read-onlycurrentPrevious 24-hours ES counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.112.1.5Columnpm100gemuxsfpPerfTelecomInputClientPast24StatHistoryEsValuePort1read-onlycurrentPrevious 24-hours ES counter :This OID gives the previous 24-hours Errored Second counter value
1.3.6.1.4.1.20044.107.11.6.112.1.6Columnpm100gemuxsfpPerfTelecomInputClientPast24StatHistoryInvSesPort1read-onlycurrentPrevious 24-hours SES counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.112.1.7Columnpm100gemuxsfpPerfTelecomInputClientPast24StatHistorySesValuePort1read-onlycurrentPrevious 24-hours SES counter :This OID gives the previous 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.107.11.6.112.1.8Columnpm100gemuxsfpPerfTelecomInputClientPast24StatHistoryInvSefsPort1read-onlycurrentPrevious 24-hours SEFS counter inv. :This OID indicates that the previous 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.112.1.9Columnpm100gemuxsfpPerfTelecomInputClientPast24StatHistorySefsValuePort1read-onlycurrentPrevious 24-hours SEFS counter :This OID gives the previous 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.107.11.6.112.1.10Columnpm100gemuxsfpPerfTelecomInputClientPast24StatHistoryInvUasPort1read-onlycurrentPrevious 24-hours UAS counter inv. :This OID indicates that the previous 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.112.1.11Columnpm100gemuxsfpPerfTelecomInputClientPast24StatHistoryUasValuePort1read-onlycurrentPrevious 24-hours UAS counter :This OID gives the previous 24-hours UnAvailable Second counter value
1.3.6.1.4.1.20044.107.11.6.144Tablepm100gemuxsfpPerfTelecomOutputClientCurrent15StatTablenot-accessiblecurrentList of pm100gemuxsfpPerfTelecomOutputClientCurrent15Stat Article
1.3.6.1.4.1.20044.107.11.6.144.1Rowpm100gemuxsfpPerfTelecomOutputClientCurrent15StatEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpPerfTelecomOutputClientCurrent15Stat table
1.3.6.1.4.1.20044.107.11.6.144.1.1Columnpm100gemuxsfpPerfTelecomOutputClientCurrent15StatIndexread-onlycurrentIndex definition for the pm100gemuxsfpPerfTelecomOutputClientCurrent15Stat table
1.3.6.1.4.1.20044.107.11.6.144.1.2Columnpm100gemuxsfpPerfTelecomOutputClientCurrent15StatInvCvPortnread-onlycurrentCurrent 15-min EBC counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.107.11.6.144.1.3Columnpm100gemuxsfpPerfTelecomOutputClientCurrent15StatCvValuePortnread-onlycurrentCurrent 15-min EBC counter :This OID gives the current 15-min Coding Violation counter value
1.3.6.1.4.1.20044.107.11.6.144.1.4Columnpm100gemuxsfpPerfTelecomOutputClientCurrent15StatInvEsPortnread-onlycurrentCurrent 15-min ES counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.144.1.5Columnpm100gemuxsfpPerfTelecomOutputClientCurrent15StatEsValuePortnread-onlycurrentCurrent 15-min ES counter :This OID gives the current 15-min Errored Second counter value
1.3.6.1.4.1.20044.107.11.6.144.1.6Columnpm100gemuxsfpPerfTelecomOutputClientCurrent15StatInvSesPortnread-onlycurrentCurrent 15-min SES counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.144.1.7Columnpm100gemuxsfpPerfTelecomOutputClientCurrent15StatSesValuePortnread-onlycurrentCurrent 15-min SES counter :This OID gives the current 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.107.11.6.144.1.8Columnpm100gemuxsfpPerfTelecomOutputClientCurrent15StatInvSefsPortnread-onlycurrentCurrent 15-min SEFS counter inv. :This OID indicates that the current 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.144.1.9Columnpm100gemuxsfpPerfTelecomOutputClientCurrent15StatSefsValuePortnread-onlycurrentCurrent 15-min SEFS counter :This OID gives the current 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.107.11.6.144.1.10Columnpm100gemuxsfpPerfTelecomOutputClientCurrent15StatInvUasPortnread-onlycurrentCurrent 15-min UAS counter inv. :This OID indicates that the current 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.144.1.11Columnpm100gemuxsfpPerfTelecomOutputClientCurrent15StatUasValuePortnread-onlycurrentCurrent 15-min UAS counter :This OID gives the current 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.107.11.6.176Tablepm100gemuxsfpPerfTelecomOutputClientPast15StatHistoryPort1Tablenot-accessiblecurrentList of pm100gemuxsfpPerfTelecomOutputClientPast15StatHistory Article
1.3.6.1.4.1.20044.107.11.6.176.1Rowpm100gemuxsfpPerfTelecomOutputClientPast15StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pm100gemuxsfpPerfTelecomOutputClientPast15StatHistory table
1.3.6.1.4.1.20044.107.11.6.176.1.1Columnpm100gemuxsfpPerfTelecomOutputClientPast15StatHistoryPort1Indexread-onlycurrentIndex definition for the pm100gemuxsfpPerfTelecomOutputClientPast15StatHistory table
1.3.6.1.4.1.20044.107.11.6.176.1.2Columnpm100gemuxsfpPerfTelecomOutputClientPast15StatHistoryInvCvPort1read-onlycurrentPrevious 15-min EBC counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.107.11.6.176.1.3Columnpm100gemuxsfpPerfTelecomOutputClientPast15StatHistoryCvValuePort1read-onlycurrentPrevious 15-min EBC counter :This OID gives the previous 15-min Coding Violation counter value
1.3.6.1.4.1.20044.107.11.6.176.1.4Columnpm100gemuxsfpPerfTelecomOutputClientPast15StatHistoryInvEsPort1read-onlycurrentPrevious 15-min ES counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.176.1.5Columnpm100gemuxsfpPerfTelecomOutputClientPast15StatHistoryEsValuePort1read-onlycurrentPrevious 15-min ES counter :This OID gives the previous 15-min Errored Second counter value
1.3.6.1.4.1.20044.107.11.6.176.1.6Columnpm100gemuxsfpPerfTelecomOutputClientPast15StatHistoryInvSesPort1read-onlycurrentPrevious 15-min SES counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.176.1.7Columnpm100gemuxsfpPerfTelecomOutputClientPast15StatHistorySesValuePort1read-onlycurrentPrevious 15-min SES counter :This OID gives the previous 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.107.11.6.176.1.8Columnpm100gemuxsfpPerfTelecomOutputClientPast15StatHistoryInvSefsPort1read-onlycurrentPrevious 15-min SEFS counter inv. :This OID indicates that the previous 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.176.1.9Columnpm100gemuxsfpPerfTelecomOutputClientPast15StatHistorySefsValuePort1read-onlycurrentPrevious 15-min SEFS counter :This OID gives the previous 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.107.11.6.176.1.10Columnpm100gemuxsfpPerfTelecomOutputClientPast15StatHistoryInvUasPort1read-onlycurrentPrevious 15-min UAS counter inv. :This OID indicates that the previous 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.176.1.11Columnpm100gemuxsfpPerfTelecomOutputClientPast15StatHistoryUasValuePort1read-onlycurrentPrevious 15-min UAS counter :This OID gives the previous 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.107.11.6.208Tablepm100gemuxsfpPerfTelecomOutputClientCurrent24StatTablenot-accessiblecurrentList of pm100gemuxsfpPerfTelecomOutputClientCurrent24Stat Article
1.3.6.1.4.1.20044.107.11.6.208.1Rowpm100gemuxsfpPerfTelecomOutputClientCurrent24StatEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpPerfTelecomOutputClientCurrent24Stat table
1.3.6.1.4.1.20044.107.11.6.208.1.1Columnpm100gemuxsfpPerfTelecomOutputClientCurrent24StatIndexread-onlycurrentIndex definition for the pm100gemuxsfpPerfTelecomOutputClientCurrent24Stat table
1.3.6.1.4.1.20044.107.11.6.208.1.2Columnpm100gemuxsfpPerfTelecomOutputClientCurrent24StatInvCvPortnread-onlycurrentCurrent 24-hours EBC counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.107.11.6.208.1.3Columnpm100gemuxsfpPerfTelecomOutputClientCurrent24StatCvValuePortnread-onlycurrentCurrent 24-hours EBC counter :This OID gives the current 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.107.11.6.208.1.4Columnpm100gemuxsfpPerfTelecomOutputClientCurrent24StatInvEsPortnread-onlycurrentCurrent 24-hours ES counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.208.1.5Columnpm100gemuxsfpPerfTelecomOutputClientCurrent24StatEsValuePortnread-onlycurrentCurrent 24-hours ES counter :This OID gives the current 24-hours Errored Second counter value
1.3.6.1.4.1.20044.107.11.6.208.1.6Columnpm100gemuxsfpPerfTelecomOutputClientCurrent24StatInvSesPortnread-onlycurrentCurrent 24-hours SES counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.208.1.7Columnpm100gemuxsfpPerfTelecomOutputClientCurrent24StatSesValuePortnread-onlycurrentCurrent 24-hours SES counter :This OID gives the current 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.107.11.6.208.1.8Columnpm100gemuxsfpPerfTelecomOutputClientCurrent24StatInvSefsPortnread-onlycurrentCurrent 24-hours SEFS counter inv. :This OID indicates that the current 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.208.1.9Columnpm100gemuxsfpPerfTelecomOutputClientCurrent24StatSefsValuePortnread-onlycurrentCurrent 24-hours SEFS counter :This OID gives the current 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.107.11.6.208.1.10Columnpm100gemuxsfpPerfTelecomOutputClientCurrent24StatInvUasPortnread-onlycurrentCurrent 24-hours UAS counter inv. :This OID indicates that the current 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.208.1.11Columnpm100gemuxsfpPerfTelecomOutputClientCurrent24StatUasValuePortnread-onlycurrentCurrent 24-hours UAS counter :This OID gives the current 24-hours UnAvailable Second counter value
1.3.6.1.4.1.20044.107.11.6.240Tablepm100gemuxsfpPerfTelecomOutputClientPast24StatHistoryPort1Tablenot-accessiblecurrentList of pm100gemuxsfpPerfTelecomOutputClientPast24StatHistory Article
1.3.6.1.4.1.20044.107.11.6.240.1Rowpm100gemuxsfpPerfTelecomOutputClientPast24StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pm100gemuxsfpPerfTelecomOutputClientPast24StatHistory table
1.3.6.1.4.1.20044.107.11.6.240.1.1Columnpm100gemuxsfpPerfTelecomOutputClientPast24StatHistoryPort1Indexread-onlycurrentIndex definition for the pm100gemuxsfpPerfTelecomOutputClientPast24StatHistory table
1.3.6.1.4.1.20044.107.11.6.240.1.2Columnpm100gemuxsfpPerfTelecomOutputClientPast24StatHistoryInvCvPort1read-onlycurrentPrevious 24-hours EBC counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.107.11.6.240.1.3Columnpm100gemuxsfpPerfTelecomOutputClientPast24StatHistoryCvValuePort1read-onlycurrentPrevious 24-hours EBC counter :This OID gives the previous 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.107.11.6.240.1.4Columnpm100gemuxsfpPerfTelecomOutputClientPast24StatHistoryInvEsPort1read-onlycurrentPrevious 24-hours ES counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.240.1.5Columnpm100gemuxsfpPerfTelecomOutputClientPast24StatHistoryEsValuePort1read-onlycurrentPrevious 24-hours ES counter :This OID gives the previous 24-hours Errored Second counter value
1.3.6.1.4.1.20044.107.11.6.240.1.6Columnpm100gemuxsfpPerfTelecomOutputClientPast24StatHistoryInvSesPort1read-onlycurrentPrevious 24-hours SES counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.240.1.7Columnpm100gemuxsfpPerfTelecomOutputClientPast24StatHistorySesValuePort1read-onlycurrentPrevious 24-hours SES counter :This OID gives the previous 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.107.11.6.240.1.8Columnpm100gemuxsfpPerfTelecomOutputClientPast24StatHistoryInvSefsPort1read-onlycurrentPrevious 24-hours SEFS counter inv. :This OID indicates that the previous 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.240.1.9Columnpm100gemuxsfpPerfTelecomOutputClientPast24StatHistorySefsValuePort1read-onlycurrentPrevious 24-hours SEFS counter :This OID gives the previous 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.107.11.6.240.1.10Columnpm100gemuxsfpPerfTelecomOutputClientPast24StatHistoryInvUasPort1read-onlycurrentPrevious 24-hours UAS counter inv. :This OID indicates that the previous 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.107.11.6.240.1.11Columnpm100gemuxsfpPerfTelecomOutputClientPast24StatHistoryUasValuePort1read-onlycurrentPrevious 24-hours UAS counter :This OID gives the previous 24-hours UnAvailable Second counter value
1.3.6.1.4.1.20044.107.11.6.848Tablepm100gemuxsfpPerfDatacomClientCurrent15StatTablenot-accessiblecurrentList of pm100gemuxsfpPerfDatacomClientCurrent15Stat Article
1.3.6.1.4.1.20044.107.11.6.848.1Rowpm100gemuxsfpPerfDatacomClientCurrent15StatEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpPerfDatacomClientCurrent15Stat table
1.3.6.1.4.1.20044.107.11.6.848.1.1Columnpm100gemuxsfpPerfDatacomClientCurrent15StatIndexread-onlycurrentIndex definition for the pm100gemuxsfpPerfDatacomClientCurrent15Stat table
1.3.6.1.4.1.20044.107.11.6.848.1.4Columnpm100gemuxsfpperfdatacomclientCurrent15StatInCrcCountInvPortnread-onlycurrentClient Current 15-min Input CRC counter inv. :This OID indicates that the current 15-min Input CRC counter is invalid
1.3.6.1.4.1.20044.107.11.6.848.1.5Columnpm100gemuxsfpperfdatacomclientCurrent15StatInCrcCountPortnread-onlycurrentClient Current 15-min Input CRC counter :This OID gives the current 15-min Input CRC counter value
1.3.6.1.4.1.20044.107.11.6.848.1.6Columnpm100gemuxsfpperfdatacomclientCurrent15StatInPacketCountInvPortnread-onlycurrentClient Current 15-min Input Packet counter inv. :This OID indicates that the current 15-min Input Packet counter is invalid
1.3.6.1.4.1.20044.107.11.6.848.1.7Columnpm100gemuxsfpperfdatacomclientCurrent15StatInPacketCountPortnread-onlycurrentClient Current 15-min Input Packet counter :This OID gives the current 15-min Input Packet counter value
1.3.6.1.4.1.20044.107.11.6.848.1.28Columnpm100gemuxsfpperfdatacomclientCurrent15StatOutCrcCountInvPortnread-onlycurrentClient Current 15-min Output CRC counter inv. :This OID indicates that the current 15-min Output CRC counter is invalid
1.3.6.1.4.1.20044.107.11.6.848.1.29Columnpm100gemuxsfpperfdatacomclientCurrent15StatOutCrcCountPortnread-onlycurrentClient Current 15-min Output CRC counter :This OID gives the current 15-min Output CRC counter value
1.3.6.1.4.1.20044.107.11.6.848.1.30Columnpm100gemuxsfpperfdatacomclientCurrent15StatOutPacketCountInvPortnread-onlycurrentClient Current 15-min Output Packet counter inv. :This OID indicates that the current 15-min Output Packets counter is invalid
1.3.6.1.4.1.20044.107.11.6.848.1.31Columnpm100gemuxsfpperfdatacomclientCurrent15StatOutPacketCountPortnread-onlycurrentClient Current 15-min Output Packet counter :This OID gives the current 15-min Output Packets counter value
1.3.6.1.4.1.20044.107.11.6.880Tablepm100gemuxsfpPerfDatacomClientPast15StatHistoryPort1Tablenot-accessiblecurrentList of pm100gemuxsfpPerfDatacomClientPast15StatHistory Article
1.3.6.1.4.1.20044.107.11.6.880.1Rowpm100gemuxsfpPerfDatacomClientPast15StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pm100gemuxsfpPerfDatacomClientPast15StatHistory table
1.3.6.1.4.1.20044.107.11.6.880.1.1Columnpm100gemuxsfpPerfDatacomClientPast15StatHistoryPort1Indexread-onlycurrentIndex definition for the pm100gemuxsfpPerfDatacomClientPast15StatHistory table
1.3.6.1.4.1.20044.107.11.6.880.1.4Columnpm100gemuxsfpperfdatacomclientPast15StatInCrcCountInvPort1read-onlycurrentClient Past 15-min Input CRC counter inv. :This OID indicates that the past 15-min Input CRC counter is invalid
1.3.6.1.4.1.20044.107.11.6.880.1.5Columnpm100gemuxsfpperfdatacomclientPast15StatInCrcCountPort1read-onlycurrentClient Past 15-min Input CRC counter :This OID gives the past 15-min Input CRC counter value
1.3.6.1.4.1.20044.107.11.6.880.1.6Columnpm100gemuxsfpperfdatacomclientPast15StatInPacketCountInvPort1read-onlycurrentClient Past 15-min Input Packet counter inv. :This OID indicates that the past 15-min Input Packet counter is invalid
1.3.6.1.4.1.20044.107.11.6.880.1.7Columnpm100gemuxsfpperfdatacomclientPast15StatInPacketCountPort1read-onlycurrentClient Past 15-min Input Packet counter :This OID gives the past 15-min Input Packet counter value
1.3.6.1.4.1.20044.107.11.6.880.1.28Columnpm100gemuxsfpperfdatacomclientPast15StatOutCrcCountInvPort1read-onlycurrentClient Past 15-min Output CRC counter inv. :This OID indicates that the past 15-min Output CRC counter is invalid
1.3.6.1.4.1.20044.107.11.6.880.1.29Columnpm100gemuxsfpperfdatacomclientPast15StatOutCrcCountPort1read-onlycurrentClient Past 15-min Output CRC counter :This OID gives the past 15-min Output CRC counter value
1.3.6.1.4.1.20044.107.11.6.880.1.30Columnpm100gemuxsfpperfdatacomclientPast15StatOutPacketCountInvPort1read-onlycurrentClient Past 15-min Output Packet counter inv. :This OID indicates that the past 15-min Output Packets counter is invalid
1.3.6.1.4.1.20044.107.11.6.880.1.31Columnpm100gemuxsfpperfdatacomclientPast15StatOutPacketCountPort1read-onlycurrentClient Past 15-min Output Packet counter :This OID gives the past 15-min Output Packets counter value
1.3.6.1.4.1.20044.107.11.6.912Tablepm100gemuxsfpPerfDatacomClientCurrent24StatTablenot-accessiblecurrentList of pm100gemuxsfpPerfDatacomClientCurrent24Stat Article
1.3.6.1.4.1.20044.107.11.6.912.1Rowpm100gemuxsfpPerfDatacomClientCurrent24StatEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpPerfDatacomClientCurrent24Stat table
1.3.6.1.4.1.20044.107.11.6.912.1.1Columnpm100gemuxsfpPerfDatacomClientCurrent24StatIndexread-onlycurrentIndex definition for the pm100gemuxsfpPerfDatacomClientCurrent24Stat table
1.3.6.1.4.1.20044.107.11.6.912.1.4Columnpm100gemuxsfpperfdatacomclientCurrent24StatInCrcCountInvPortnread-onlycurrentClient Current 24-hours Input CRC counter inv. :This OID indicates that the current 24-hours Input CRC counter is invalid
1.3.6.1.4.1.20044.107.11.6.912.1.5Columnpm100gemuxsfpperfdatacomclientCurrent24StatInCrcCountPortnread-onlycurrentClient Current 24-hours Input CRC counter :This OID gives the current 24-hours Input CRC counter value
1.3.6.1.4.1.20044.107.11.6.912.1.6Columnpm100gemuxsfpperfdatacomclientCurrent24StatInPacketCountInvPortnread-onlycurrentClient Current 24-hours Input Packet counter inv. :This OID indicates that the current 24-hours Input Packet counter is invalid
1.3.6.1.4.1.20044.107.11.6.912.1.7Columnpm100gemuxsfpperfdatacomclientCurrent24StatInPacketCountPortnread-onlycurrentClient Current 24-hours Input Packet counter :This OID gives the current 24-hours Input Packet counter value
1.3.6.1.4.1.20044.107.11.6.912.1.28Columnpm100gemuxsfpperfdatacomclientCurrent24StatOutCrcCountInvPortnread-onlycurrentClient Current 24-hours Output CRC counter inv. :This OID indicates that the current 24-hours Output CRC counter is invalid
1.3.6.1.4.1.20044.107.11.6.912.1.29Columnpm100gemuxsfpperfdatacomclientCurrent24StatOutCrcCountPortnread-onlycurrentClient Current 24-hours Output CRC counter :This OID gives the current 24-hours Output CRC counter value
1.3.6.1.4.1.20044.107.11.6.912.1.30Columnpm100gemuxsfpperfdatacomclientCurrent24StatOutPacketCountInvPortnread-onlycurrentClient Current 24-hours Output Packet counter inv. :This OID indicates that the current 24-hours Output Packets counter is invalid
1.3.6.1.4.1.20044.107.11.6.912.1.31Columnpm100gemuxsfpperfdatacomclientCurrent24StatOutPacketCountPortnread-onlycurrentClient Current 24-hours Output Packet counter :This OID gives the current 24-hours Output Packets counter value
1.3.6.1.4.1.20044.107.11.6.944Tablepm100gemuxsfpPerfDatacomClientPast24StatHistoryPort1Tablenot-accessiblecurrentList of pm100gemuxsfpPerfDatacomClientPast24StatHistory Article
1.3.6.1.4.1.20044.107.11.6.944.1Rowpm100gemuxsfpPerfDatacomClientPast24StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pm100gemuxsfpPerfDatacomClientPast24StatHistory table
1.3.6.1.4.1.20044.107.11.6.944.1.1Columnpm100gemuxsfpPerfDatacomClientPast24StatHistoryPort1Indexread-onlycurrentIndex definition for the pm100gemuxsfpPerfDatacomClientPast24StatHistory table
1.3.6.1.4.1.20044.107.11.6.944.1.4Columnpm100gemuxsfpperfdatacomclientPast24StatInCrcCountInvPort1read-onlycurrentClient Past 24-hours Input CRC counter inv. :This OID indicates that the past 24-hours Input CRC counter is invalid
1.3.6.1.4.1.20044.107.11.6.944.1.5Columnpm100gemuxsfpperfdatacomclientPast24StatInCrcCountPort1read-onlycurrentClient Past 24-hours Input CRC counter :This OID gives the past 24-hours Input CRC counter value
1.3.6.1.4.1.20044.107.11.6.944.1.6Columnpm100gemuxsfpperfdatacomclientPast24StatInPacketCountInvPort1read-onlycurrentClient Past 24-hours Input Packet counter inv. :This OID indicates that the past 24-hours Input Packet counter is invalid
1.3.6.1.4.1.20044.107.11.6.944.1.7Columnpm100gemuxsfpperfdatacomclientPast24StatInPacketCountPort1read-onlycurrentClient Past 24-hours Input Packet counter :This OID gives the past 24-hours Input Packet counter value
1.3.6.1.4.1.20044.107.11.6.944.1.28Columnpm100gemuxsfpperfdatacomclientPast24StatOutCrcCountInvPort1read-onlycurrentClient Past 24-hours Output CRC counter inv. :This OID indicates that the past 24-hours Output CRC counter is invalid
1.3.6.1.4.1.20044.107.11.6.944.1.29Columnpm100gemuxsfpperfdatacomclientPast24StatOutCrcCountPort1read-onlycurrentClient Past 24-hours Output CRC counter :This OID gives the past 24-hours Output CRC counter value
1.3.6.1.4.1.20044.107.11.6.944.1.30Columnpm100gemuxsfpperfdatacomclientPast24StatOutPacketCountInvPort1read-onlycurrentClient Past 24-hours Output Packet counter inv. :This OID indicates that the past 24-hours Output Packets counter is invalid
1.3.6.1.4.1.20044.107.11.6.944.1.31Columnpm100gemuxsfpperfdatacomclientPast24StatOutPacketCountPort1read-onlycurrentClient Past 24-hours Output Packet counter :This OID gives the past 24-hours Output Packets counter value
1.3.6.1.4.1.20044.107.11.7Nodepm100gemuxsfpMonPerfLine
1.3.6.1.4.1.20044.107.11.7.336Tablepm100gemuxsfpPerfTelecomLinePostFecCurrent15StatTablenot-accessiblecurrentList of pm100gemuxsfpPerfTelecomLinePostFecCurrent15Stat Article
1.3.6.1.4.1.20044.107.11.7.336.1Rowpm100gemuxsfpPerfTelecomLinePostFecCurrent15StatEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpPerfTelecomLinePostFecCurrent15Stat table
1.3.6.1.4.1.20044.107.11.7.336.1.1Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent15StatIndexread-onlycurrentIndex definition for the pm100gemuxsfpPerfTelecomLinePostFecCurrent15Stat table
1.3.6.1.4.1.20044.107.11.7.336.1.2Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent15StatInvCvPortnread-onlycurrentCurrent 15-min EBC counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.107.11.7.336.1.3Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent15StatCvValuePortnread-onlycurrentCurrent 15-min EBC counter :This OID gives the current 15-min Coding Violation counter value
1.3.6.1.4.1.20044.107.11.7.336.1.4Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent15StatInvEsPortnread-onlycurrentCurrent 15-min ES counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.7.336.1.5Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent15StatEsValuePortnread-onlycurrentCurrent 15-min ES counter :This OID gives the current 15-min Errored Second counter value
1.3.6.1.4.1.20044.107.11.7.336.1.6Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent15StatInvSesPortnread-onlycurrentCurrent 15-min SES counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.7.336.1.7Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent15StatSesValuePortnread-onlycurrentCurrent 15-min SES counter :This OID gives the current 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.107.11.7.336.1.8Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent15StatInvSefsPortnread-onlycurrentCurrent 15-min SEFS counter inv. :This OID indicates that the current 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.107.11.7.336.1.9Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent15StatSefsValuePortnread-onlycurrentCurrent 15-min SEFS counter :This OID gives the current 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.107.11.7.336.1.10Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent15StatInvUasPortnread-onlycurrentCurrent 15-min UAS counter inv. :This OID indicates that the current 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.107.11.7.336.1.11Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent15StatUasValuePortnread-onlycurrentCurrent 15-min UAS counter :This OID gives the current 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.107.11.7.337Tablepm100gemuxsfpPerfTelecomLinePostFecPast15StatHistoryPort1Tablenot-accessiblecurrentList of pm100gemuxsfpPerfTelecomLinePostFecPast15StatHistory Article
1.3.6.1.4.1.20044.107.11.7.337.1Rowpm100gemuxsfpPerfTelecomLinePostFecPast15StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pm100gemuxsfpPerfTelecomLinePostFecPast15StatHistory table
1.3.6.1.4.1.20044.107.11.7.337.1.1Columnpm100gemuxsfpPerfTelecomLinePostFecPast15StatHistoryPort1Indexread-onlycurrentIndex definition for the pm100gemuxsfpPerfTelecomLinePostFecPast15StatHistory table
1.3.6.1.4.1.20044.107.11.7.337.1.2Columnpm100gemuxsfpPerfTelecomLinePostFecPast15StatHistoryInvCvPort1read-onlycurrentPrevious 15-min EBC counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.107.11.7.337.1.3Columnpm100gemuxsfpPerfTelecomLinePostFecPast15StatHistoryCvValuePort1read-onlycurrentPrevious 15-min EBC counter :This OID gives the previous 15-min Coding Violation counter value
1.3.6.1.4.1.20044.107.11.7.337.1.4Columnpm100gemuxsfpPerfTelecomLinePostFecPast15StatHistoryInvEsPort1read-onlycurrentPrevious 15-min ES counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.7.337.1.5Columnpm100gemuxsfpPerfTelecomLinePostFecPast15StatHistoryEsValuePort1read-onlycurrentPrevious 15-min ES counter :This OID gives the previous 15-min Errored Second counter value
1.3.6.1.4.1.20044.107.11.7.337.1.6Columnpm100gemuxsfpPerfTelecomLinePostFecPast15StatHistoryInvSesPort1read-onlycurrentPrevious 15-min SES counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.7.337.1.7Columnpm100gemuxsfpPerfTelecomLinePostFecPast15StatHistorySesValuePort1read-onlycurrentPrevious 15-min SES counter :This OID gives the previous 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.107.11.7.337.1.8Columnpm100gemuxsfpPerfTelecomLinePostFecPast15StatHistoryInvSefsPort1read-onlycurrentPrevious 15-min SEFS counter inv. :This OID indicates that the previous 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.107.11.7.337.1.9Columnpm100gemuxsfpPerfTelecomLinePostFecPast15StatHistorySefsValuePort1read-onlycurrentPrevious 15-min SEFS counter :This OID gives the previous 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.107.11.7.337.1.10Columnpm100gemuxsfpPerfTelecomLinePostFecPast15StatHistoryInvUasPort1read-onlycurrentPrevious 15-min UAS counter inv. :This OID indicates that the previous 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.107.11.7.337.1.11Columnpm100gemuxsfpPerfTelecomLinePostFecPast15StatHistoryUasValuePort1read-onlycurrentPrevious 15-min UAS counter :This OID gives the previous 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.107.11.7.338Tablepm100gemuxsfpPerfTelecomLinePostFecCurrent24StatTablenot-accessiblecurrentList of pm100gemuxsfpPerfTelecomLinePostFecCurrent24Stat Article
1.3.6.1.4.1.20044.107.11.7.338.1Rowpm100gemuxsfpPerfTelecomLinePostFecCurrent24StatEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpPerfTelecomLinePostFecCurrent24Stat table
1.3.6.1.4.1.20044.107.11.7.338.1.1Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent24StatIndexread-onlycurrentIndex definition for the pm100gemuxsfpPerfTelecomLinePostFecCurrent24Stat table
1.3.6.1.4.1.20044.107.11.7.338.1.2Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent24StatInvCvPortnread-onlycurrentCurrent 24-hours EBC counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.107.11.7.338.1.3Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent24StatCvValuePortnread-onlycurrentCurrent 24-hours EBC counter :This OID gives the current 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.107.11.7.338.1.4Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent24StatInvEsPortnread-onlycurrentCurrent 24-hours ES counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.7.338.1.5Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent24StatEsValuePortnread-onlycurrentCurrent 24-hours ES counter :This OID gives the current 24-hours Errored Second counter value
1.3.6.1.4.1.20044.107.11.7.338.1.6Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent24StatInvSesPortnread-onlycurrentCurrent 24-hours SES counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.7.338.1.7Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent24StatSesValuePortnread-onlycurrentCurrent 24-hours SES counter :This OID gives the current 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.107.11.7.338.1.8Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent24StatInvSefsPortnread-onlycurrentCurrent 24-hours SEFS counter inv. :This OID indicates that the current 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.107.11.7.338.1.9Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent24StatSefsValuePortnread-onlycurrentCurrent 24-hours SEFS counter :This OID gives the current 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.107.11.7.338.1.10Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent24StatInvUasPortnread-onlycurrentCurrent 24-hours UAS counter inv. :This OID indicates that the current 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.107.11.7.338.1.11Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent24StatUasValuePortnread-onlycurrentCurrent 24-hours UAS counter :This OID gives the current 24-hours UnAvailable Second counter value
1.3.6.1.4.1.20044.107.11.7.339Tablepm100gemuxsfpPerfTelecomLinePostFecPast24StatHistoryPort1Tablenot-accessiblecurrentList of pm100gemuxsfpPerfTelecomLinePostFecPast24StatHistory Article
1.3.6.1.4.1.20044.107.11.7.339.1Rowpm100gemuxsfpPerfTelecomLinePostFecPast24StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pm100gemuxsfpPerfTelecomLinePostFecPast24StatHistory table
1.3.6.1.4.1.20044.107.11.7.339.1.1Columnpm100gemuxsfpPerfTelecomLinePostFecPast24StatHistoryPort1Indexread-onlycurrentIndex definition for the pm100gemuxsfpPerfTelecomLinePostFecPast24StatHistory table
1.3.6.1.4.1.20044.107.11.7.339.1.2Columnpm100gemuxsfpPerfTelecomLinePostFecPast24StatHistoryInvCvPort1read-onlycurrentPrevious 24-hours EBC counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.107.11.7.339.1.3Columnpm100gemuxsfpPerfTelecomLinePostFecPast24StatHistoryCvValuePort1read-onlycurrentPrevious 24-hours EBC counter :This OID gives the previous 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.107.11.7.339.1.4Columnpm100gemuxsfpPerfTelecomLinePostFecPast24StatHistoryInvEsPort1read-onlycurrentPrevious 24-hours ES counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.7.339.1.5Columnpm100gemuxsfpPerfTelecomLinePostFecPast24StatHistoryEsValuePort1read-onlycurrentPrevious 24-hours ES counter :This OID gives the previous 24-hours Errored Second counter value
1.3.6.1.4.1.20044.107.11.7.339.1.6Columnpm100gemuxsfpPerfTelecomLinePostFecPast24StatHistoryInvSesPort1read-onlycurrentPrevious 24-hours SES counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.7.339.1.7Columnpm100gemuxsfpPerfTelecomLinePostFecPast24StatHistorySesValuePort1read-onlycurrentPrevious 24-hours SES counter :This OID gives the previous 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.107.11.7.339.1.8Columnpm100gemuxsfpPerfTelecomLinePostFecPast24StatHistoryInvSefsPort1read-onlycurrentPrevious 24-hours SEFS counter inv. :This OID indicates that the previous 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.107.11.7.339.1.9Columnpm100gemuxsfpPerfTelecomLinePostFecPast24StatHistorySefsValuePort1read-onlycurrentPrevious 24-hours SEFS counter :This OID gives the previous 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.107.11.7.339.1.10Columnpm100gemuxsfpPerfTelecomLinePostFecPast24StatHistoryInvUasPort1read-onlycurrentPrevious 24-hours UAS counter inv. :This OID indicates that the previous 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.107.11.7.339.1.11Columnpm100gemuxsfpPerfTelecomLinePostFecPast24StatHistoryUasValuePort1read-onlycurrentPrevious 24-hours UAS counter :This OID gives the previous 24-hours UnAvailable Second counter value
1.3.6.1.4.1.20044.107.11.7.352Tablepm100gemuxsfpPerfTelecomBerLinePreFecCurrent15StatTablenot-accessiblecurrentList of pm100gemuxsfpPerfTelecomBerLinePreFecCurrent15Stat Article
1.3.6.1.4.1.20044.107.11.7.352.1Rowpm100gemuxsfpPerfTelecomBerLinePreFecCurrent15StatEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpPerfTelecomBerLinePreFecCurrent15Stat table
1.3.6.1.4.1.20044.107.11.7.352.1.1Columnpm100gemuxsfpPerfTelecomBerLinePreFecCurrent15StatIndexread-onlycurrentIndex definition for the pm100gemuxsfpPerfTelecomBerLinePreFecCurrent15Stat table
1.3.6.1.4.1.20044.107.11.7.352.1.2Columnpm100gemuxsfpPerfTelecomBerLinePreFecCurrent15StatInvBerPortnread-onlycurrentCurrent 15-min BER counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.107.11.7.352.1.3Columnpm100gemuxsfpPerfTelecomBerLinePreFecCurrent15StatBerValuePortnread-onlycurrentCurrent 15-min BER counter :This OID gives the current 15-min Coding Violation counter value
1.3.6.1.4.1.20044.107.11.7.352.1.4Columnpm100gemuxsfpPerfTelecomBerLinePreFecCurrent15StatInvMinBerPortnread-onlycurrentCurrent 15-min MinBER counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.7.352.1.5Columnpm100gemuxsfpPerfTelecomBerLinePreFecCurrent15StatMinBerValuePortnread-onlycurrentCurrent 15-min MinBER counter :This OID gives the current 15-min Errored Second counter value
1.3.6.1.4.1.20044.107.11.7.352.1.6Columnpm100gemuxsfpPerfTelecomBerLinePreFecCurrent15StatInvMaxBerPortnread-onlycurrentCurrent 15-min MaxBER counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.7.352.1.7Columnpm100gemuxsfpPerfTelecomBerLinePreFecCurrent15StatMaxBerValuePortnread-onlycurrentCurrent 15-min MaxBER counter :This OID gives the current 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.107.11.7.353Tablepm100gemuxsfpPerfTelecomBerLinePreFecPast15StatHistoryPort1Tablenot-accessiblecurrentList of pm100gemuxsfpPerfTelecomBerLinePreFecPast15StatHistory Article
1.3.6.1.4.1.20044.107.11.7.353.1Rowpm100gemuxsfpPerfTelecomBerLinePreFecPast15StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pm100gemuxsfpPerfTelecomBerLinePreFecPast15StatHistory table
1.3.6.1.4.1.20044.107.11.7.353.1.1Columnpm100gemuxsfpPerfTelecomBerLinePreFecPast15StatHistoryPort1Indexread-onlycurrentIndex definition for the pm100gemuxsfpPerfTelecomBerLinePreFecPast15StatHistory table
1.3.6.1.4.1.20044.107.11.7.353.1.2Columnpm100gemuxsfpPerfTelecomBerLinePreFecPast15StatHistoryInvBerPort1read-onlycurrentPrevious 15-min BER counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.107.11.7.353.1.3Columnpm100gemuxsfpPerfTelecomBerLinePreFecPast15StatHistoryBerValuePort1read-onlycurrentPrevious 15-min BER counter :This OID gives the previous 15-min Coding Violation counter value
1.3.6.1.4.1.20044.107.11.7.353.1.4Columnpm100gemuxsfpPerfTelecomBerLinePreFecPast15StatHistoryInvMinBerPort1read-onlycurrentPrevious 15-min MinBER counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.7.353.1.5Columnpm100gemuxsfpPerfTelecomBerLinePreFecPast15StatHistoryMinBerValuePort1read-onlycurrentPrevious 15-min MinBER counter :This OID gives the previous 15-min Errored Second counter value
1.3.6.1.4.1.20044.107.11.7.353.1.6Columnpm100gemuxsfpPerfTelecomBerLinePreFecPast15StatHistoryInvMaxBerPort1read-onlycurrentPrevious 15-min MaxBER counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.7.353.1.7Columnpm100gemuxsfpPerfTelecomBerLinePreFecPast15StatHistoryMaxBerValuePort1read-onlycurrentPrevious 15-min MaxBER counter :This OID gives the previous 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.107.11.7.354Tablepm100gemuxsfpPerfTelecomBerLinePreFecCurrent24StatTablenot-accessiblecurrentList of pm100gemuxsfpPerfTelecomBerLinePreFecCurrent24Stat Article
1.3.6.1.4.1.20044.107.11.7.354.1Rowpm100gemuxsfpPerfTelecomBerLinePreFecCurrent24StatEntrynot-accessiblecurrentRow definition for the pm100gemuxsfpPerfTelecomBerLinePreFecCurrent24Stat table
1.3.6.1.4.1.20044.107.11.7.354.1.1Columnpm100gemuxsfpPerfTelecomBerLinePreFecCurrent24StatIndexread-onlycurrentIndex definition for the pm100gemuxsfpPerfTelecomBerLinePreFecCurrent24Stat table
1.3.6.1.4.1.20044.107.11.7.354.1.2Columnpm100gemuxsfpPerfTelecomBerLinePreFecCurrent24StatInvBerPortnread-onlycurrentCurrent 24-hours BER counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.107.11.7.354.1.3Columnpm100gemuxsfpPerfTelecomBerLinePreFecCurrent24StatBerValuePortnread-onlycurrentCurrent 24-hours BER counter :This OID gives the current 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.107.11.7.354.1.4Columnpm100gemuxsfpPerfTelecomBerLinePreFecCurrent24StatInvMinBerPortnread-onlycurrentCurrent 24-hoursMinBER counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.7.354.1.5Columnpm100gemuxsfpPerfTelecomBerLinePreFecCurrent24StatMinBerValuePortnread-onlycurrentCurrent 24-hours MinBER counter :This OID gives the current 24-hours Errored Second counter value
1.3.6.1.4.1.20044.107.11.7.354.1.6Columnpm100gemuxsfpPerfTelecomBerLinePreFecCurrent24StatInvMaxBerPortnread-onlycurrentCurrent 24-hours MaxBER counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.7.354.1.7Columnpm100gemuxsfpPerfTelecomBerLinePreFecCurrent24StatMaxBerValuePortnread-onlycurrentCurrent 24-hours MaxBER counter :This OID gives the current 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.107.11.7.355Tablepm100gemuxsfpPerfTelecomBerLinePreFecPast24StatHistoryPort1Tablenot-accessiblecurrentList of pm100gemuxsfpPerfTelecomBerLinePreFecPast24StatHistory Article
1.3.6.1.4.1.20044.107.11.7.355.1Rowpm100gemuxsfpPerfTelecomBerLinePreFecPast24StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pm100gemuxsfpPerfTelecomBerLinePreFecPast24StatHistory table
1.3.6.1.4.1.20044.107.11.7.355.1.1Columnpm100gemuxsfpPerfTelecomBerLinePreFecPast24StatHistoryPort1Indexread-onlycurrentIndex definition for the pm100gemuxsfpPerfTelecomBerLinePreFecPast24StatHistory table
1.3.6.1.4.1.20044.107.11.7.355.1.2Columnpm100gemuxsfpPerfTelecomBerLinePreFecPast24StatHistoryInvBerPort1read-onlycurrentPrevious 24-hours BER counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.107.11.7.355.1.3Columnpm100gemuxsfpPerfTelecomBerLinePreFecPast24StatHistoryBerValuePort1read-onlycurrentPrevious 24-hours BER counter :This OID gives the previous 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.107.11.7.355.1.4Columnpm100gemuxsfpPerfTelecomBerLinePreFecPast24StatHistoryInvMinBerPort1read-onlycurrentPrevious 24-hours MinBER counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.7.355.1.5Columnpm100gemuxsfpPerfTelecomBerLinePreFecPast24StatHistoryMinBerValuePort1read-onlycurrentPrevious 24-hours MinBER counter :This OID gives the previous 24-hours Errored Second counter value
1.3.6.1.4.1.20044.107.11.7.355.1.6Columnpm100gemuxsfpPerfTelecomBerLinePreFecPast24StatHistoryInvMaxBerPort1read-onlycurrentPrevious 24-hours MaxBER counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.107.11.7.355.1.7Columnpm100gemuxsfpPerfTelecomBerLinePreFecPast24StatHistoryMaxBerValuePort1read-onlycurrentPrevious 24-hours MaxBER counter :This OID gives the previous 24-hours severely Errored Second counter value
Type Definitions
NameSyntaxStatusDescription
Pm100gemuxsfpModuleModeINTEGER { modulemode2x40g(1), modulemode1x40g4x10g(2), modulemode10x10g(3) }currentDifferent values on the module mode