EKINOPS-Pm100gemuxsfp-MIB
961 objects
Creation.
Imported Objects
| EKINOPS-MIB | EkiApiState EkiMeasureType EkiMode ekinops EkiOnOff EkiProtocol EkiState EkiSynchroMode |
| SNMPv2-SMI | Counter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20044.107 | IdentitymodulePm100gemuxsfp | Creation. | ||
| 1.3.6.1.4.1.20044.107.2 | Nodepm100gemuxsfpalarms | |||
| 1.3.6.1.4.1.20044.107.2.1 | Nodepm100gemuxsfpAlmOther | |||
| 1.3.6.1.4.1.20044.107.2.1.1 | Nodepm100gemuxsfpAlmOtherNurg | |||
| 1.3.6.1.4.1.20044.107.2.1.1.2 | Nodepm100gemuxsfpAlmsynthAlm2 | |||
| 1.3.6.1.4.1.20044.107.2.1.1.2.1 | Scalarpm100gemuxsfpAlmConfTableSave | read-only | current | PM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> infor… |
| 1.3.6.1.4.1.20044.107.2.1.1.2.2 | Scalarpm100gemuxsfpAlmInvUpload | read-only | current | Inventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> informationalStatus(1000) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.107.2.1.1.2.3 | Scalarpm100gemuxsfpAlmConfTableLoad | read-only | current | PM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> informationalStat… |
| 1.3.6.1.4.1.20044.107.2.1.1.2.4 | Scalarpm100gemuxsfpAlmCorrelatOff | read-only | current | Not Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> informationalStatus(1000) <Alarmtype… |
| 1.3.6.1.4.1.20044.107.2.1.1.2.5 | Scalarpm100gemuxsfpAlmMaintenanceOn | read-only | current | Maintenance Mode :This OID indicates that the RM is in maintenance mode. <Help> This alarm indicates that the maintenance mode is enabled on the PM <Condtype> … |
| 1.3.6.1.4.1.20044.107.2.1.2 | Nodepm100gemuxsfpAlmOtherUrg | |||
| 1.3.6.1.4.1.20044.107.2.1.3 | Nodepm100gemuxsfpAlmOtherCrit | |||
| 1.3.6.1.4.1.20044.107.2.1.3.0 | Nodepm100gemuxsfpAlmsynthAlm0 | |||
| 1.3.6.1.4.1.20044.107.2.1.3.0.2 | Scalarpm100gemuxsfpAlmFailFan | read-only | current | Fan Fail :This OID is at 1 when any fail occurs on the fan tray <Help> This alarm indicates that the Fan tray module is in a failure condition <Condtype> FAIL_… |
| 1.3.6.1.4.1.20044.107.2.1.3.0.9 | Scalarpm100gemuxsfpAlmModGlobFail | read-only | current | Module Failure :This OID is set on detection of a failure originating from the RM <Help> This alarm is set on detection of a failure originating from the equip… |
| 1.3.6.1.4.1.20044.107.2.1.3.0.15 | Scalarpm100gemuxsfpAlmDefFuseA | read-only | current | Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.107.2.1.3.0.16 | Scalarpm100gemuxsfpAlmDefFuseB | read-only | current | Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.107.2.2 | Nodepm100gemuxsfpAlmClient | |||
| 1.3.6.1.4.1.20044.107.2.2.1 | Nodepm100gemuxsfpAlmClientNurg | |||
| 1.3.6.1.4.1.20044.107.2.2.1.272 | Tablepm100gemuxsfpAlmclientSfpWarnDdmTable | not-accessible | current | List of pm100gemuxsfpAlmclientSfpWarnDdm Article |
| 1.3.6.1.4.1.20044.107.2.2.1.272.1 | Rowpm100gemuxsfpAlmclientSfpWarnDdmEntry | not-accessible | current | Row definition for the pm100gemuxsfpAlmclientSfpWarnDdm table |
| 1.3.6.1.4.1.20044.107.2.2.1.272.1.1 | Columnpm100gemuxsfpAlmclientSfpWarnDdmIndex | read-only | current | Index definition for the pm100gemuxsfpAlmclientSfpWarnDdm table |
| 1.3.6.1.4.1.20044.107.2.2.1.272.1.2 | Columnpm100gemuxsfpAlmTxPwLowWngPortn | read-only | current | Client Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning … |
| 1.3.6.1.4.1.20044.107.2.2.1.272.1.3 | Columnpm100gemuxsfpAlmTxPwrHighWngPortn | read-only | current | Client Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warnin… |
| 1.3.6.1.4.1.20044.107.2.2.1.272.1.4 | Columnpm100gemuxsfpAlmTxBiasLowWngPortn | read-only | current | Client Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warnin… |
| 1.3.6.1.4.1.20044.107.2.2.1.272.1.5 | Columnpm100gemuxsfpAlmTxBiasHighWngPortn | read-only | current | Client Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warn… |
| 1.3.6.1.4.1.20044.107.2.2.1.272.1.6 | Columnpm100gemuxsfpAlmVccLowWngPortn | read-only | current | Client Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Warn… |
| 1.3.6.1.4.1.20044.107.2.2.1.272.1.7 | Columnpm100gemuxsfpAlmVccHighWngPortn | read-only | current | Client Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Wa… |
| 1.3.6.1.4.1.20044.107.2.2.1.272.1.8 | Columnpm100gemuxsfpAlmTempLowWngPortn | read-only | current | Client Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indic… |
| 1.3.6.1.4.1.20044.107.2.2.1.272.1.9 | Columnpm100gemuxsfpAlmTempHighWngPortn | read-only | current | Client Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning ind… |
| 1.3.6.1.4.1.20044.107.2.2.1.272.1.16 | Columnpm100gemuxsfpAlmRxPwrLowWngPortn | read-only | current | Client Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning i… |
| 1.3.6.1.4.1.20044.107.2.2.1.272.1.17 | Columnpm100gemuxsfpAlmRxPwrHighWngPortn | read-only | current | Client Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning… |
| 1.3.6.1.4.1.20044.107.2.2.2 | Nodepm100gemuxsfpAlmClientUrg | |||
| 1.3.6.1.4.1.20044.107.2.2.2.152 | Tablepm100gemuxsfpAlmclientHostLaneFaultTable | not-accessible | current | List of pm100gemuxsfpAlmclientHostLaneFault Article |
| 1.3.6.1.4.1.20044.107.2.2.2.152.1 | Rowpm100gemuxsfpAlmclientHostLaneFaultEntry | not-accessible | current | Row definition for the pm100gemuxsfpAlmclientHostLaneFault table |
| 1.3.6.1.4.1.20044.107.2.2.2.152.1.1 | Columnpm100gemuxsfpAlmclientHostLaneFaultIndex | read-only | current | Index definition for the pm100gemuxsfpAlmclientHostLaneFault table |
| 1.3.6.1.4.1.20044.107.2.2.2.152.1.2 | Columnpm100gemuxsfpAlmClientLossOfSyncPortn | read-only | current | Client Frame Alignment Loss :This OID indicates the module is not aligned with the incoming Client signal <Help> Alarm indicating the module is not aligned wit… |
| 1.3.6.1.4.1.20044.107.2.2.2.152.1.3 | Columnpm100gemuxsfpAlmClientInputLossOfSigPortn | read-only | current | Client Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Client Trscv <Help> Alarm indicating a Loss of Signal is detected on the Cl… |
| 1.3.6.1.4.1.20044.107.2.2.2.152.1.4 | Columnpm100gemuxsfpAlmClientLanesMarkerUnlockPortn | read-only | current | Client Lanes Marker Unlock :This OID indicates the Client lanes marker alignment is not lock <Help> Alarm indicating the Client lanes marker alignment is not l… |
| 1.3.6.1.4.1.20044.107.2.2.2.152.1.5 | Columnpm100gemuxsfpAlmClientLanes6466UnlockPortn | read-only | current | Client Lanes 64/66b Unlock :This OID indicates the Client 64/66b decoder is not lock <Help> Alarm indicating the Client 64/66b decoder is not lock <Condtype> C… |
| 1.3.6.1.4.1.20044.107.2.2.2.152.1.6 | Columnpm100gemuxsfpAlmClientLanesNotAlignedPortn | read-only | current | Client Lanes Not Aligned :This OID indicates the Client lanes are not aligned <Help> Alarm indicating the Client lanes are not aligned <Condtype> CLIENT_LANES_… |
| 1.3.6.1.4.1.20044.107.2.2.2.152.1.7 | Columnpm100gemuxsfpAlmClientCsfDetectedPortn | read-only | current | Client Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client… |
| 1.3.6.1.4.1.20044.107.2.2.2.152.1.10 | Columnpm100gemuxsfpAlmClientTxHostLolPortn | read-only | current | Client Host Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Client Trscv Host Lane <Help> Alarm indicating a Tx Loss of Lock on the Client Tr… |
| 1.3.6.1.4.1.20044.107.2.2.2.152.1.11 | Columnpm100gemuxsfpAlmClientLaneTxFifoErrorPortn | read-only | current | Client Host Lane Tx FIFO Error :This OID indicates a Tx FIFO Error on the Client Trscv Host Lane <Help> Alarm indicating a Tx FIFO Error on the Client Trscv Ho… |
| 1.3.6.1.4.1.20044.107.2.2.2.152.1.15 | Columnpm100gemuxsfpAlmClientLinkStatusPortn | read-only | current | Client Link Status :This OID indicates a Client linkup linkdown status <Help> This alarm indicates a Client linkup lindown status <Condtype> CLIENT_LINK_STATUS… |
| 1.3.6.1.4.1.20044.107.2.2.2.152.1.16 | Columnpm100gemuxsfpAlmClientRxFaultPortn | read-only | current | Client Rx Fault :This OID indicates a Client Rx fault on the receive path <Help> This alarm indicates a Client Rx fault on the receive path <Condtype> CLIENT_R… |
| 1.3.6.1.4.1.20044.107.2.2.2.152.1.17 | Columnpm100gemuxsfpAlmClientTxFaultPortn | read-only | current | Client Tx Fault :This OID indicates a Client Tx fault on the transmit path <Help> This alarm indicates a Client Tx fault on the transmit path <Condtype> CLIENT… |
| 1.3.6.1.4.1.20044.107.2.2.2.240 | Tablepm100gemuxsfpAlmclientSfpAlmDdmTable | not-accessible | current | List of pm100gemuxsfpAlmclientSfpAlmDdm Article |
| 1.3.6.1.4.1.20044.107.2.2.2.240.1 | Rowpm100gemuxsfpAlmclientSfpAlmDdmEntry | not-accessible | current | Row definition for the pm100gemuxsfpAlmclientSfpAlmDdm table |
| 1.3.6.1.4.1.20044.107.2.2.2.240.1.1 | Columnpm100gemuxsfpAlmclientSfpAlmDdmIndex | read-only | current | Index definition for the pm100gemuxsfpAlmclientSfpAlmDdm table |
| 1.3.6.1.4.1.20044.107.2.2.2.240.1.2 | Columnpm100gemuxsfpAlmTxPwrLowAlaPortn | read-only | current | Client Trscv Tx Power Low :This OID indicates that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in… |
| 1.3.6.1.4.1.20044.107.2.2.2.240.1.3 | Columnpm100gemuxsfpAlmTxPwrHighAlaPortn | read-only | current | Client Trscv Tx Power High :This OID indicates that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm … |
| 1.3.6.1.4.1.20044.107.2.2.2.240.1.4 | Columnpm100gemuxsfpAlmTxBiasLowAlaPortn | read-only | current | Client Trscv Bias Low :This OID indicates that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm … |
| 1.3.6.1.4.1.20044.107.2.2.2.240.1.5 | Columnpm100gemuxsfpAlmTxBiasHighAlaPortn | read-only | current | Client Trscv Bias High :This OID indicates that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM <Help> Alar… |
| 1.3.6.1.4.1.20044.107.2.2.2.240.1.6 | Columnpm100gemuxsfpAlmVccLowAlaPortn | read-only | current | Client Trscv Power Supply Low :This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM <Help> Alar… |
| 1.3.6.1.4.1.20044.107.2.2.2.240.1.7 | Columnpm100gemuxsfpAlmVccHighAlaPortn | read-only | current | Client Trscv Power Supply High :This OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM <Help> Al… |
| 1.3.6.1.4.1.20044.107.2.2.2.240.1.8 | Columnpm100gemuxsfpAlmTempLowAlaPortn | read-only | current | Client Trscv Temp Low :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicat… |
| 1.3.6.1.4.1.20044.107.2.2.2.240.1.9 | Columnpm100gemuxsfpAlmTempHighAlaPortn | read-only | current | Client Trscv Temp High :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indic… |
| 1.3.6.1.4.1.20044.107.2.2.2.240.1.16 | Columnpm100gemuxsfpAlmRxPwrLowAlaPortn | read-only | current | Client Trscv Rx Power Low :This OID indicates that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm ind… |
| 1.3.6.1.4.1.20044.107.2.2.2.240.1.17 | Columnpm100gemuxsfpAlmRxPwrHighAlaPortn | read-only | current | Client Trscv Rx Power High :This OID indicates that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm i… |
| 1.3.6.1.4.1.20044.107.2.2.3 | Nodepm100gemuxsfpAlmClientCrit | |||
| 1.3.6.1.4.1.20044.107.2.2.3.8 | Tablepm100gemuxsfpAlmsynthAlmPortTable | not-accessible | current | List of pm100gemuxsfpAlmsynthAlmPort Article |
| 1.3.6.1.4.1.20044.107.2.2.3.8.1 | Rowpm100gemuxsfpAlmsynthAlmPortEntry | not-accessible | current | Row definition for the pm100gemuxsfpAlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.107.2.2.3.8.1.1 | Columnpm100gemuxsfpAlmsynthAlmPortIndex | read-only | current | Index definition for the pm100gemuxsfpAlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.107.2.2.3.8.1.2 | Columnpm100gemuxsfpAlmSfpAbsentPortn | read-only | current | Client Optical Module Absent :This OID indicates that the Transceiver is not present in the client port. <Help> This alarm indicates if the client transceiver … |
| 1.3.6.1.4.1.20044.107.2.2.3.8.1.3 | Columnpm100gemuxsfpAlmDdmAbsentPortn | read-only | current | DDM Supported On Client Trscv :This OID indicates that the Client transceiver supports the Digital Diagnostic Monitoring function <Help> This status indicates … |
| 1.3.6.1.4.1.20044.107.2.2.3.8.1.5 | Columnpm100gemuxsfpAlmHwFailAccPortn | read-only | current | Client HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Help> This alarm indicates a failure on client port, most pro… |
| 1.3.6.1.4.1.20044.107.2.2.3.8.1.6 | Columnpm100gemuxsfpAlmDwLsdPortn | read-only | current | Client Trscv Laser Shutdown :This OID indicates the Client transceiver laser is shutdown <Help> This status indicates if the client transceiver laser is shutdo… |
| 1.3.6.1.4.1.20044.107.2.2.3.8.1.7 | Columnpm100gemuxsfpAlmClientLocalOosPortn | read-only | current | Local Client Port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local c… |
| 1.3.6.1.4.1.20044.107.2.2.3.8.1.8 | Columnpm100gemuxsfpAlmClientRemoteOosPortn | read-only | current | Remote Client Port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the remot… |
| 1.3.6.1.4.1.20044.107.2.2.3.8.1.9 | Columnpm100gemuxsfpAlmDwCaisPortn | read-only | current | Client AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indicates if a Client Alarm Indication Signal is… |
| 1.3.6.1.4.1.20044.107.2.2.3.8.1.10 | Columnpm100gemuxsfpAlmSfpDdmWarningPortn | read-only | current | Warning On Client Trscv DDM :This OID indicates a warning is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Warning has be… |
| 1.3.6.1.4.1.20044.107.2.2.3.8.1.11 | Columnpm100gemuxsfpAlmSfpDdmAlmPortn | read-only | current | Alarm On Client Trscv DDM :This OID indicates an alarm is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Alarm has been de… |
| 1.3.6.1.4.1.20044.107.2.2.3.8.1.13 | Columnpm100gemuxsfpAlmFailAccPortn | read-only | current | Client Access Fail :This OID indicates a failure on the Client port <Help> This alarm indicates a failure on the Client port <Condtype> FAIL_ACC_1 <Probcause> … |
| 1.3.6.1.4.1.20044.107.2.2.3.8.1.17 | Columnpm100gemuxsfpAlmUpCsfPortn | read-only | current | Client Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu… |
| 1.3.6.1.4.1.20044.107.2.3 | Nodepm100gemuxsfpAlmLine | |||
| 1.3.6.1.4.1.20044.107.2.3.1 | Nodepm100gemuxsfpAlmLineNurg | |||
| 1.3.6.1.4.1.20044.107.2.3.1.72 | Tablepm100gemuxsfpAlmlineQsfpAlmDdmTable | not-accessible | current | List of pm100gemuxsfpAlmlineQsfpAlmDdm Article |
| 1.3.6.1.4.1.20044.107.2.3.1.72.1 | Rowpm100gemuxsfpAlmlineQsfpAlmDdmEntry | not-accessible | current | Row definition for the pm100gemuxsfpAlmlineQsfpAlmDdm table |
| 1.3.6.1.4.1.20044.107.2.3.1.72.1.1 | Columnpm100gemuxsfpAlmlineQsfpAlmDdmIndex | read-only | current | Index definition for the pm100gemuxsfpAlmlineQsfpAlmDdm table |
| 1.3.6.1.4.1.20044.107.2.3.1.72.1.2 | Columnpm100gemuxsfpAlmLineTxPwLowAlmPortn | read-only | current | Client Trscv Tx Power Low Alarm :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indi… |
| 1.3.6.1.4.1.20044.107.2.3.1.72.1.3 | Columnpm100gemuxsfpAlmLineTxPwrHighAlmPortn | read-only | current | Client Trscv Tx Power High Alarm :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm in… |
| 1.3.6.1.4.1.20044.107.2.3.1.72.1.4 | Columnpm100gemuxsfpAlmLineTxBiasLowAlmPortn | read-only | current | Client Trscv Bias Low Alarm :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in… |
| 1.3.6.1.4.1.20044.107.2.3.1.72.1.5 | Columnpm100gemuxsfpAlmLineTxBiasHighAlmPortn | read-only | current | Client Trscv Bias High Alarm :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Alarm … |
| 1.3.6.1.4.1.20044.107.2.3.1.72.1.6 | Columnpm100gemuxsfpAlmLineVccLowAlmPortn | read-only | current | Client Trscv Power Supply Low Alarm :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Alarm … |
| 1.3.6.1.4.1.20044.107.2.3.1.72.1.7 | Columnpm100gemuxsfpAlmLineVccHighAlmPortn | read-only | current | Client Trscv Power Supply High Alarm :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Alar… |
| 1.3.6.1.4.1.20044.107.2.3.1.72.1.8 | Columnpm100gemuxsfpAlmLineTempLowAlmPortn | read-only | current | Client Trscv Temp Low Alarm :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicatin… |
| 1.3.6.1.4.1.20044.107.2.3.1.72.1.9 | Columnpm100gemuxsfpAlmLineTempHighAlmPortn | read-only | current | Client Trscv Temp High Alarm :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indicat… |
| 1.3.6.1.4.1.20044.107.2.3.1.72.1.16 | Columnpm100gemuxsfpAlmLineRxPwrLowAlmPortn | read-only | current | Client Trscv Rx Power Low Alarm :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indic… |
| 1.3.6.1.4.1.20044.107.2.3.1.72.1.17 | Columnpm100gemuxsfpAlmLineRxPwrHighAlmPortn | read-only | current | Client Trscv Rx Power High Alarm :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm ind… |
| 1.3.6.1.4.1.20044.107.2.3.1.104 | Tablepm100gemuxsfpAlmlineQsfpWarnDdmTable | not-accessible | current | List of pm100gemuxsfpAlmlineQsfpWarnDdm Article |
| 1.3.6.1.4.1.20044.107.2.3.1.104.1 | Rowpm100gemuxsfpAlmlineQsfpWarnDdmEntry | not-accessible | current | Row definition for the pm100gemuxsfpAlmlineQsfpWarnDdm table |
| 1.3.6.1.4.1.20044.107.2.3.1.104.1.1 | Columnpm100gemuxsfpAlmlineQsfpWarnDdmIndex | read-only | current | Index definition for the pm100gemuxsfpAlmlineQsfpWarnDdm table |
| 1.3.6.1.4.1.20044.107.2.3.1.104.1.2 | Columnpm100gemuxsfpAlmLineTxPwLowWngPortn | read-only | current | Client Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning … |
| 1.3.6.1.4.1.20044.107.2.3.1.104.1.3 | Columnpm100gemuxsfpAlmLineTxPwrHighWngPortn | read-only | current | Client Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warnin… |
| 1.3.6.1.4.1.20044.107.2.3.1.104.1.4 | Columnpm100gemuxsfpAlmLineTxBiasLowWngPortn | read-only | current | Client Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warnin… |
| 1.3.6.1.4.1.20044.107.2.3.1.104.1.5 | Columnpm100gemuxsfpAlmLineTxBiasHighWngPortn | read-only | current | Client Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warn… |
| 1.3.6.1.4.1.20044.107.2.3.1.104.1.6 | Columnpm100gemuxsfpAlmLineVccLowWngPortn | read-only | current | Client Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Warn… |
| 1.3.6.1.4.1.20044.107.2.3.1.104.1.7 | Columnpm100gemuxsfpAlmLineVccHighWngPortn | read-only | current | Client Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Wa… |
| 1.3.6.1.4.1.20044.107.2.3.1.104.1.8 | Columnpm100gemuxsfpAlmLineTempLowWngPortn | read-only | current | Client Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indic… |
| 1.3.6.1.4.1.20044.107.2.3.1.104.1.9 | Columnpm100gemuxsfpAlmLineTempHighWngPortn | read-only | current | Client Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning ind… |
| 1.3.6.1.4.1.20044.107.2.3.1.104.1.16 | Columnpm100gemuxsfpAlmLineRxPwrLowWngPortn | read-only | current | Client Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning i… |
| 1.3.6.1.4.1.20044.107.2.3.1.104.1.17 | Columnpm100gemuxsfpAlmLineRxPwrHighWngPortn | read-only | current | Client Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning… |
| 1.3.6.1.4.1.20044.107.2.3.1.184 | Tablepm100gemuxsfpAlmlineNetworkLaneAlarmWarning1Table | not-accessible | current | List of pm100gemuxsfpAlmlineNetworkLaneAlarmWarning1 Article |
| 1.3.6.1.4.1.20044.107.2.3.1.184.1 | Rowpm100gemuxsfpAlmlineNetworkLaneAlarmWarning1Entry | not-accessible | current | Row definition for the pm100gemuxsfpAlmlineNetworkLaneAlarmWarning1 table |
| 1.3.6.1.4.1.20044.107.2.3.1.184.1.1 | Columnpm100gemuxsfpAlmlineNetworkLaneAlarmWarning1Index | read-only | current | Index definition for the pm100gemuxsfpAlmlineNetworkLaneAlarmWarning1 table |
| 1.3.6.1.4.1.20044.107.2.3.1.184.1.2 | Columnpm100gemuxsfpAlmLineRxPowerLowAlarmPortn | read-only | current | Line Trscv Rx Power Low Alarm :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicat… |
| 1.3.6.1.4.1.20044.107.2.3.1.184.1.3 | Columnpm100gemuxsfpAlmLineRxPowerLowWarningPortn | read-only | current | Line Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning ind… |
| 1.3.6.1.4.1.20044.107.2.3.1.184.1.4 | Columnpm100gemuxsfpAlmLineRxPowerHighWarningPortn | read-only | current | Line Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning i… |
| 1.3.6.1.4.1.20044.107.2.3.1.184.1.5 | Columnpm100gemuxsfpAlmLineRxPowerHighAlarmPortn | read-only | current | Line Trscv Rx Power High Alarm :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indic… |
| 1.3.6.1.4.1.20044.107.2.3.1.184.1.6 | Columnpm100gemuxsfpAlmLineLaserTempLowAlarmPortn | read-only | current | Line Trscv Tx Laser Temp Low Alarm :This OID indicates that the Trscv Tx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help>… |
| 1.3.6.1.4.1.20044.107.2.3.1.184.1.7 | Columnpm100gemuxsfpAlmLineLaserTempLowWarningPortn | read-only | current | Line Trscv Tx Laser Temp Low Warning :This OID indicates that the Trscv Tx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Hel… |
| 1.3.6.1.4.1.20044.107.2.3.1.184.1.8 | Columnpm100gemuxsfpAlmLineLaserTempHighWarningPortn | read-only | current | Line Trscv Tx Laser Temp High Warning :This OID indicates that the Trscv Tx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <H… |
| 1.3.6.1.4.1.20044.107.2.3.1.184.1.9 | Columnpm100gemuxsfpAlmLineLaserTempHighAlarmPortn | read-only | current | Line Trscv Tx Laser Temp High Alarm :This OID indicates that the Trscv Tx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Hel… |
| 1.3.6.1.4.1.20044.107.2.3.1.184.1.10 | Columnpm100gemuxsfpAlmLineTxPowerLowAlarmPortn | read-only | current | Line Trscv Tx Power Low Alarm :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indica… |
| 1.3.6.1.4.1.20044.107.2.3.1.184.1.11 | Columnpm100gemuxsfpAlmLineTxPowerLowWarningPortn | read-only | current | Line Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning in… |
| 1.3.6.1.4.1.20044.107.2.3.1.184.1.12 | Columnpm100gemuxsfpAlmLineTxPowerHighWarningPortn | read-only | current | Line Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warning … |
| 1.3.6.1.4.1.20044.107.2.3.1.184.1.13 | Columnpm100gemuxsfpAlmLineTxPowerHighAlarmPortn | read-only | current | Line Trscv Tx Power High Alarm :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indi… |
| 1.3.6.1.4.1.20044.107.2.3.1.184.1.14 | Columnpm100gemuxsfpAlmLineBiasLowAlarmPortn | read-only | current | Line Trscv Tx Bias Low Alarm :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alarm i… |
| 1.3.6.1.4.1.20044.107.2.3.1.184.1.15 | Columnpm100gemuxsfpAlmLineBiasLowWarningPortn | read-only | current | Line Trscv Tx Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warni… |
| 1.3.6.1.4.1.20044.107.2.3.1.184.1.16 | Columnpm100gemuxsfpAlmLineBiasHighWarningPortn | read-only | current | Line Trscv Tx Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> War… |
| 1.3.6.1.4.1.20044.107.2.3.1.184.1.17 | Columnpm100gemuxsfpAlmLineBiasHighAlarmPortn | read-only | current | Line Trscv Tx Bias High Alarm :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Alarm… |
| 1.3.6.1.4.1.20044.107.2.3.1.188 | Tablepm100gemuxsfpAlmlineNetworkLaneAlarmWarning2Table | not-accessible | current | List of pm100gemuxsfpAlmlineNetworkLaneAlarmWarning2 Article |
| 1.3.6.1.4.1.20044.107.2.3.1.188.1 | Rowpm100gemuxsfpAlmlineNetworkLaneAlarmWarning2Entry | not-accessible | current | Row definition for the pm100gemuxsfpAlmlineNetworkLaneAlarmWarning2 table |
| 1.3.6.1.4.1.20044.107.2.3.1.188.1.1 | Columnpm100gemuxsfpAlmlineNetworkLaneAlarmWarning2Index | read-only | current | Index definition for the pm100gemuxsfpAlmlineNetworkLaneAlarmWarning2 table |
| 1.3.6.1.4.1.20044.107.2.3.1.188.1.2 | Columnpm100gemuxsfpAlmTxModulatorBiasLowAlarmPortn | read-only | current | Line Trscv Tx Modulator Bias Low Alarm :This OID indicates that the Trscv Tx modulator bias current is lower than the threshold value written in the Trscv EEPR… |
| 1.3.6.1.4.1.20044.107.2.3.1.188.1.3 | Columnpm100gemuxsfpAlmTxModulatorBiasLowWarningPortn | read-only | current | Line Trscv Tx Modulator Bias Low Warning :This OID indicates that the Trscv Tx modulator bias current is lower than the threshold value written in the Trscv EE… |
| 1.3.6.1.4.1.20044.107.2.3.1.188.1.4 | Columnpm100gemuxsfpAlmTxModulatorBiasHighWarningPortn | read-only | current | Line Trscv Tx Modulator Bias High Warning :This OID indicates that the Trscv Tx modulator bias current is higher than the threshold value written in the Trscv … |
| 1.3.6.1.4.1.20044.107.2.3.1.188.1.5 | Columnpm100gemuxsfpAlmTxModulatorBiasHighAlarmPortn | read-only | current | Line Trscv Tx Modulator Bias High Alarm :This OID indicates that the Trscv Tx modulator bias current is higher than the threshold value written in the Trscv EE… |
| 1.3.6.1.4.1.20044.107.2.3.1.188.1.6 | Columnpm100gemuxsfpAlmRxLaserTempLowAlarmPortn | read-only | current | Line Trscv Rx Laser Temp Low Alarm :This OID indicates that the Trscv Rx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help>… |
| 1.3.6.1.4.1.20044.107.2.3.1.188.1.7 | Columnpm100gemuxsfpAlmRxLaserTempLowWarningPortn | read-only | current | Line Trscv Rx Laser Temp Low Warning :This OID indicates that the Trscv Rx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Hel… |
| 1.3.6.1.4.1.20044.107.2.3.1.188.1.8 | Columnpm100gemuxsfpAlmRxLaserTempHighWarningPortn | read-only | current | Line Trscv Rx Laser Temp High Warning :This OID indicates that the Trscv Rx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <H… |
| 1.3.6.1.4.1.20044.107.2.3.1.188.1.9 | Columnpm100gemuxsfpAlmRxLaserTempHighAlarmPortn | read-only | current | Line Trscv Rx Laser Temp High Alarm :This OID indicates that the Trscv Rx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Hel… |
| 1.3.6.1.4.1.20044.107.2.3.1.188.1.10 | Columnpm100gemuxsfpAlmRxLaserOutputLowAlarmPortn | read-only | current | Line Trscv Rx Output Power Low Alarm :This OID indicates that the Trscv Rx output power is lower than the threshold value written in the Trscv EEPROM <Help> Al… |
| 1.3.6.1.4.1.20044.107.2.3.1.188.1.11 | Columnpm100gemuxsfpAlmRxLaserOutputLowWarningPortn | read-only | current | Line Trscv Rx Output Power Low Warning :This OID indicates that the Trscv Rx output power is lower than the threshold value written in the Trscv EEPROM <Help> … |
| 1.3.6.1.4.1.20044.107.2.3.1.188.1.12 | Columnpm100gemuxsfpAlmRxLaserOutputHighWarningPortn | read-only | current | Line Trscv Rx Output Power High Warning :This OID indicates that the Trscv Rx output power is higher than the threshold value written in the Trscv EEPROM <Help… |
| 1.3.6.1.4.1.20044.107.2.3.1.188.1.13 | Columnpm100gemuxsfpAlmRxLaserOutputHighAlarmPortn | read-only | current | Line Trscv Rx Output Power High Alarm :This OID indicates that the Trscv Rx output power is higher than the threshold value written in the Trscv EEPROM <Help> … |
| 1.3.6.1.4.1.20044.107.2.3.1.188.1.14 | Columnpm100gemuxsfpAlmRxLaserBiasLowAlarmPortn | read-only | current | Line Trscv Rx Bias Low Alarm :This OID indicates that the Trscv Rx laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alar… |
| 1.3.6.1.4.1.20044.107.2.3.1.188.1.15 | Columnpm100gemuxsfpAlmRxLaserBiasLowWarningPortn | read-only | current | Line Trscv Rx Bias Low Warning :This OID indicates that the Trscv Rx laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Wa… |
| 1.3.6.1.4.1.20044.107.2.3.1.188.1.16 | Columnpm100gemuxsfpAlmRxLaserBiasHighWarningPortn | read-only | current | Line Trscv Rx Bias High Warning :This OID indicates that the Trscv Rx laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> … |
| 1.3.6.1.4.1.20044.107.2.3.1.188.1.17 | Columnpm100gemuxsfpAlmRxLaserBiasHighAlarmPortn | read-only | current | Line Trscv Rx Bias High Alarm :This OID indicates that the Trscv Rx laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Al… |
| 1.3.6.1.4.1.20044.107.2.3.2 | Nodepm100gemuxsfpAlmLineUrg | |||
| 1.3.6.1.4.1.20044.107.2.3.2.196 | Tablepm100gemuxsfpAlmlineHostLaneFaultTable | not-accessible | current | List of pm100gemuxsfpAlmlineHostLaneFault Article |
| 1.3.6.1.4.1.20044.107.2.3.2.196.1 | Rowpm100gemuxsfpAlmlineHostLaneFaultEntry | not-accessible | current | Row definition for the pm100gemuxsfpAlmlineHostLaneFault table |
| 1.3.6.1.4.1.20044.107.2.3.2.196.1.1 | Columnpm100gemuxsfpAlmlineHostLaneFaultIndex | read-only | current | Index definition for the pm100gemuxsfpAlmlineHostLaneFault table |
| 1.3.6.1.4.1.20044.107.2.3.2.196.1.2 | Columnpm100gemuxsfpAlmLineInputLossOfSignalPortn | read-only | current | Line Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Line Trscv <Help> Alarm indicating a Loss of Signal is detected on the Line T… |
| 1.3.6.1.4.1.20044.107.2.3.2.196.1.3 | Columnpm100gemuxsfpAlmLineLossOfFramePortn | read-only | current | Line Loss Of Frame :This OID indicates the module is not aligned with the incoming Line signal <Help> Alarm indicating the module is not aligned with the incom… |
| 1.3.6.1.4.1.20044.107.2.3.2.196.1.4 | Columnpm100gemuxsfpAlmLineSmBdiInsertedPortn | read-only | current | Line SM BDI Inserted :This OID indicates a SM Backward Defect Indication is inserted on the outgoing Line signal <Help> Status indicating a SM Backward Defect … |
| 1.3.6.1.4.1.20044.107.2.3.2.196.1.5 | Columnpm100gemuxsfpAlmLineSmBdiDetectedPortn | read-only | current | Line SM BDI Detected :This OID indicates a SM Backward Defect Indication is detected on the incoming Line signal <Help> Alarm indicating a SM Backward Defect I… |
| 1.3.6.1.4.1.20044.107.2.3.2.196.1.6 | Columnpm100gemuxsfpAlmLineSmIaeInsertedPortn | read-only | current | Line SM IAE Inserted :This OID indicates a SM Incoming Alignment Error is inserted on the outgoing Line signal <Help> Status indicating a SM Incoming Alignment… |
| 1.3.6.1.4.1.20044.107.2.3.2.196.1.7 | Columnpm100gemuxsfpAlmLineSmIaeDetectedPortn | read-only | current | Line SM IAE Detected :This OID indicates a SM Incoming Alignment Error is detected on the incoming Line signal <Help> Alarm indicating a SM Incoming Alignment … |
| 1.3.6.1.4.1.20044.107.2.3.2.196.1.15 | Columnpm100gemuxsfpAlmLineLinkStatusPortn | read-only | current | Line Link Status :This OID indicates a Line linkup linkdown status <Help> This alarm indicates a Line linkup lindown status <Condtype> LINE_LINK_STATUS <Probca… |
| 1.3.6.1.4.1.20044.107.2.3.2.196.1.16 | Columnpm100gemuxsfpAlmLineRxFaultPortn | read-only | current | Line Rx Fault :This OID indicates a Line Rx fault on the receive path <Help> This alarm indicates a Line Rx fault on the receive path <Condtype> LINE_RX_FAULT … |
| 1.3.6.1.4.1.20044.107.2.3.2.196.1.17 | Columnpm100gemuxsfpAlmLineTxFaultPortn | read-only | current | Line Tx Fault :This OID indicates a Line Tx fault on the transmit path <Help> This alarm indicates a Line Tx fault on the transmit path <Condtype> LINE_TX_FAUL… |
| 1.3.6.1.4.1.20044.107.2.3.3 | Nodepm100gemuxsfpAlmLineCrit | |||
| 1.3.6.1.4.1.20044.107.2.3.3.40 | Tablepm100gemuxsfpAlmsynthAlmLineTable | not-accessible | current | List of pm100gemuxsfpAlmsynthAlmLine Article |
| 1.3.6.1.4.1.20044.107.2.3.3.40.1 | Rowpm100gemuxsfpAlmsynthAlmLineEntry | not-accessible | current | Row definition for the pm100gemuxsfpAlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.107.2.3.3.40.1.1 | Columnpm100gemuxsfpAlmsynthAlmLineIndex | read-only | current | Index definition for the pm100gemuxsfpAlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.107.2.3.3.40.1.2 | Columnpm100gemuxsfpAlmXfpAbsentPortn | read-only | current | Line Optical Module Absent :This OID indicates that the line optical interface is not present. <Help> This alarm indicates if the line transceiver is not plugg… |
| 1.3.6.1.4.1.20044.107.2.3.3.40.1.3 | Columnpm100gemuxsfpAlmXfpInitNotComplPortn | read-only | current | Line Optical Module Ready :This OID indicates that the optical interface is not operational. <Help> This status indicates if the line transceiver has been corr… |
| 1.3.6.1.4.1.20044.107.2.3.3.40.1.5 | Columnpm100gemuxsfpAlmLineHwFailPortn | read-only | current | Line Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Help> This alarm indicates a failure on line port, most pr… |
| 1.3.6.1.4.1.20044.107.2.3.3.40.1.6 | Columnpm100gemuxsfpAlmXfpTxOffPortn | read-only | current | Line Trscv Laser Shutdown :This OID indicates the Line transceiver laser is shutdown <Help> This status indicates if the Line transceiver laser is shutdown <Co… |
| 1.3.6.1.4.1.20044.107.2.3.3.40.1.7 | Columnpm100gemuxsfpAlmLineLocalOosPortn | read-only | current | Line Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service… |
| 1.3.6.1.4.1.20044.107.2.3.3.40.1.9 | Columnpm100gemuxsfpAlmUpRdiInsPortn | read-only | current | MS-RDI/L-RDI Inserted On Line :This OID indicates an upstream MS-RDI/L-RDI has been inserted in the outgoing 10 Gb/s SDH/SONET signal. <Help> This status indic… |
| 1.3.6.1.4.1.20044.107.2.3.3.40.1.10 | Columnpm100gemuxsfpAlmLineDdmWarningPortn | read-only | current | Warning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Warning has… |
| 1.3.6.1.4.1.20044.107.2.3.3.40.1.11 | Columnpm100gemuxsfpAlmLineDdmAlmPortn | read-only | current | Alarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Alarm has been… |
| 1.3.6.1.4.1.20044.107.2.3.3.40.1.13 | Columnpm100gemuxsfpAlmLineFailPortn | read-only | current | Line Port Failure :This OID indicates a failure on the line port <Help> This alarm indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipm… |
| 1.3.6.1.4.1.20044.107.2.3.3.40.1.17 | Columnpm100gemuxsfpAlmLineActivePortn | read-only | current | Line Active :This OID indicates whether the line is active or standby. <Help> This status indicates whether the line is active or standby. <Condtype> LINE_ACTI… |
| 1.3.6.1.4.1.20044.107.3 | Nodepm100gemuxsfpmeasures | |||
| 1.3.6.1.4.1.20044.107.3.1 | Nodepm100gemuxsfpMesrOther | |||
| 1.3.6.1.4.1.20044.107.3.1.0 | Scalarpm100gemuxsfpMesrsynth0 | read-only | deprecated | Not Used : |
| 1.3.6.1.4.1.20044.107.3.1.1 | Scalarpm100gemuxsfpMesrsynth1 | read-only | deprecated | Not Used : |
| 1.3.6.1.4.1.20044.107.3.1.7 | Scalarpm100gemuxsfpMesrpmIntervalNumber | read-only | current | PM Interval Counter : |
| 1.3.6.1.4.1.20044.107.3.1.252 | Scalarpm100gemuxsfpMesrregVoltage | read-only | current | Regulator Voltage :This OID gives the voltage value of the Regulator (Voltage = AV_U16) (Unit = mV) <Help> This Measure gives the Regulator Voltage |
| 1.3.6.1.4.1.20044.107.3.1.253 | Scalarpm100gemuxsfpMesrregCurrent | read-only | current | Regulator Current :This OID gives the current value of the Regulator (Current = AV_U16/1000) (Unit = A) <Help> This Measure gives the Regulator Current |
| 1.3.6.1.4.1.20044.107.3.1.254 | Scalarpm100gemuxsfpMesrregTemp | read-only | current | Regulator Temperature :This OID gives the temperature value of the Regulator (Temperature = AV_S16) (Unit = C) <Help> This Measure gives the Regulator Temperat… |
| 1.3.6.1.4.1.20044.107.3.1.500 | Scalarpm100gemuxsfpMesrmoduleTempMin | read-only | current | Min Module Temperature :This OID gives the minimum temperature value of the Module (Temperature = AV_S16/256) (Unit = C) <Help> This Measure gives the minimum … |
| 1.3.6.1.4.1.20044.107.3.1.501 | Scalarpm100gemuxsfpMesrmoduleTempMax | read-only | current | Max Module Temperature :This OID gives the maximum temperature value of the Module (Temperature = AV_S16/256) (Unit = C) <Help> This Measure gives the maximum … |
| 1.3.6.1.4.1.20044.107.3.2 | Nodepm100gemuxsfpMesrClient | |||
| 1.3.6.1.4.1.20044.107.3.2.16 | Tablepm100gemuxsfpMesrclientTxTempTable | not-accessible | current | List of pm100gemuxsfpMesrclientTxTemp Article |
| 1.3.6.1.4.1.20044.107.3.2.16.1 | Rowpm100gemuxsfpMesrclientTxTempEntry | not-accessible | current | Row definition for the pm100gemuxsfpMesrclientTxTemp table |
| 1.3.6.1.4.1.20044.107.3.2.16.1.1 | Columnpm100gemuxsfpMesrclientTxTempIndex | read-only | current | Index definition for the pm100gemuxsfpMesrclientTxTemp table |
| 1.3.6.1.4.1.20044.107.3.2.16.1.2 | Columnpm100gemuxsfpMesrclientTxTempPortn | read-only | current | Client Trscv Temperature :This OID gives the Laser temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature … |
| 1.3.6.1.4.1.20044.107.3.2.48 | Tablepm100gemuxsfpMesrclientTxBiasTable | not-accessible | current | List of pm100gemuxsfpMesrclientTxBias Article |
| 1.3.6.1.4.1.20044.107.3.2.48.1 | Rowpm100gemuxsfpMesrclientTxBiasEntry | not-accessible | current | Row definition for the pm100gemuxsfpMesrclientTxBias table |
| 1.3.6.1.4.1.20044.107.3.2.48.1.1 | Columnpm100gemuxsfpMesrclientTxBiasIndex | read-only | current | Index definition for the pm100gemuxsfpMesrclientTxBias table |
| 1.3.6.1.4.1.20044.107.3.2.48.1.2 | Columnpm100gemuxsfpMesrclientTxBiasPortn | read-only | current | Client Trscv Laser Bias :This OID gives the Laser bias value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV_U16/500) (… |
| 1.3.6.1.4.1.20044.107.3.2.80 | Tablepm100gemuxsfpMesrclientTxPwrTable | not-accessible | current | List of pm100gemuxsfpMesrclientTxPwr Article |
| 1.3.6.1.4.1.20044.107.3.2.80.1 | Rowpm100gemuxsfpMesrclientTxPwrEntry | not-accessible | current | Row definition for the pm100gemuxsfpMesrclientTxPwr table |
| 1.3.6.1.4.1.20044.107.3.2.80.1.1 | Columnpm100gemuxsfpMesrclientTxPwrIndex | read-only | current | Index definition for the pm100gemuxsfpMesrclientTxPwr table |
| 1.3.6.1.4.1.20044.107.3.2.80.1.2 | Columnpm100gemuxsfpMesrclientTxPwrPortn | read-only | current | Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_… |
| 1.3.6.1.4.1.20044.107.3.2.112 | Tablepm100gemuxsfpMesrclientRxPwrTable | not-accessible | current | List of pm100gemuxsfpMesrclientRxPwr Article |
| 1.3.6.1.4.1.20044.107.3.2.112.1 | Rowpm100gemuxsfpMesrclientRxPwrEntry | not-accessible | current | Row definition for the pm100gemuxsfpMesrclientRxPwr table |
| 1.3.6.1.4.1.20044.107.3.2.112.1.1 | Columnpm100gemuxsfpMesrclientRxPwrIndex | read-only | current | Index definition for the pm100gemuxsfpMesrclientRxPwr table |
| 1.3.6.1.4.1.20044.107.3.2.112.1.2 | Columnpm100gemuxsfpMesrclientRxPwrPortn | read-only | current | Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16… |
| 1.3.6.1.4.1.20044.107.3.2.416 | Tablepm100gemuxsfpMesrclientTempMinTable | not-accessible | current | List of pm100gemuxsfpMesrclientTempMin Article |
| 1.3.6.1.4.1.20044.107.3.2.416.1 | Rowpm100gemuxsfpMesrclientTempMinEntry | not-accessible | current | Row definition for the pm100gemuxsfpMesrclientTempMin table |
| 1.3.6.1.4.1.20044.107.3.2.416.1.1 | Columnpm100gemuxsfpMesrclientTempMinIndex | read-only | current | Index definition for the pm100gemuxsfpMesrclientTempMin table |
| 1.3.6.1.4.1.20044.107.3.2.416.1.2 | Columnpm100gemuxsfpMesrclientTempMinPortn | read-only | current | Min Client Trscv Temperature :This OID gives the minimum temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temper… |
| 1.3.6.1.4.1.20044.107.3.2.448 | Tablepm100gemuxsfpMesrclientTempMaxTable | not-accessible | current | List of pm100gemuxsfpMesrclientTempMax Article |
| 1.3.6.1.4.1.20044.107.3.2.448.1 | Rowpm100gemuxsfpMesrclientTempMaxEntry | not-accessible | current | Row definition for the pm100gemuxsfpMesrclientTempMax table |
| 1.3.6.1.4.1.20044.107.3.2.448.1.1 | Columnpm100gemuxsfpMesrclientTempMaxIndex | read-only | current | Index definition for the pm100gemuxsfpMesrclientTempMax table |
| 1.3.6.1.4.1.20044.107.3.2.448.1.2 | Columnpm100gemuxsfpMesrclientTempMaxPortn | read-only | current | Max Client Trscv Temperature :This OID gives the maximum temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temper… |
| 1.3.6.1.4.1.20044.107.3.3 | Nodepm100gemuxsfpMesrLine | |||
| 1.3.6.1.4.1.20044.107.3.3.12 | Scalarpm100gemuxsfpMesrlineMsaTemp | read-only | current | Line Trscv Temperature :This OID gives the temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV_S16/2… |
| 1.3.6.1.4.1.20044.107.3.3.13 | Scalarpm100gemuxsfpMesrlineMsa3v3Voltage | read-only | current | Line Trscv Voltage :This OID gives the 3V3 voltage value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV_U16/10000) (U… |
| 1.3.6.1.4.1.20044.107.3.3.144 | Tablepm100gemuxsfpMesrlineTxPwrMinTable | not-accessible | current | List of pm100gemuxsfpMesrlineTxPwrMin Article |
| 1.3.6.1.4.1.20044.107.3.3.144.1 | Rowpm100gemuxsfpMesrlineTxPwrMinEntry | not-accessible | current | Row definition for the pm100gemuxsfpMesrlineTxPwrMin table |
| 1.3.6.1.4.1.20044.107.3.3.144.1.1 | Columnpm100gemuxsfpMesrlineTxPwrMinIndex | read-only | current | Index definition for the pm100gemuxsfpMesrlineTxPwrMin table |
| 1.3.6.1.4.1.20044.107.3.3.144.1.2 | Columnpm100gemuxsfpMesrlineTxPwrMinPortn | read-only | current | Min Line Trscv Tx Power :This OID gives the minimum transmit power value among the network lanes of the Line Transceiver, read from the DDM (Digital Diagnostic… |
| 1.3.6.1.4.1.20044.107.3.3.160 | Tablepm100gemuxsfpMesrlineTxCompositePwrTable | not-accessible | current | List of pm100gemuxsfpMesrlineTxCompositePwr Article |
| 1.3.6.1.4.1.20044.107.3.3.160.1 | Rowpm100gemuxsfpMesrlineTxCompositePwrEntry | not-accessible | current | Row definition for the pm100gemuxsfpMesrlineTxCompositePwr table |
| 1.3.6.1.4.1.20044.107.3.3.160.1.1 | Columnpm100gemuxsfpMesrlineTxCompositePwrIndex | read-only | current | Index definition for the pm100gemuxsfpMesrlineTxCompositePwr table |
| 1.3.6.1.4.1.20044.107.3.3.160.1.2 | Columnpm100gemuxsfpMesrlineTxCompositePwrPortn | read-only | current | Line Composite Tx Power (LR4/SR4) :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Line Transceiver, read from the… |
| 1.3.6.1.4.1.20044.107.3.3.176 | Tablepm100gemuxsfpMesrlineRxPwrMinTable | not-accessible | current | List of pm100gemuxsfpMesrlineRxPwrMin Article |
| 1.3.6.1.4.1.20044.107.3.3.176.1 | Rowpm100gemuxsfpMesrlineRxPwrMinEntry | not-accessible | current | Row definition for the pm100gemuxsfpMesrlineRxPwrMin table |
| 1.3.6.1.4.1.20044.107.3.3.176.1.1 | Columnpm100gemuxsfpMesrlineRxPwrMinIndex | read-only | current | Index definition for the pm100gemuxsfpMesrlineRxPwrMin table |
| 1.3.6.1.4.1.20044.107.3.3.176.1.2 | Columnpm100gemuxsfpMesrlineRxPwrMinPortn | read-only | current | Min Line Trscv Rx Power :This OID gives the minimum receive power value among the network lanes of the Line Transceiver, read from the DDM (Digital Diagnostic … |
| 1.3.6.1.4.1.20044.107.3.3.192 | Tablepm100gemuxsfpMesrlineRxCompositePwrTable | not-accessible | current | List of pm100gemuxsfpMesrlineRxCompositePwr Article |
| 1.3.6.1.4.1.20044.107.3.3.192.1 | Rowpm100gemuxsfpMesrlineRxCompositePwrEntry | not-accessible | current | Row definition for the pm100gemuxsfpMesrlineRxCompositePwr table |
| 1.3.6.1.4.1.20044.107.3.3.192.1.1 | Columnpm100gemuxsfpMesrlineRxCompositePwrIndex | read-only | current | Index definition for the pm100gemuxsfpMesrlineRxCompositePwr table |
| 1.3.6.1.4.1.20044.107.3.3.192.1.2 | Columnpm100gemuxsfpMesrlineRxCompositePwrPortn | read-only | current | Line Composite Rx Power (LR4/SR4) :This OID gives the composite receive power (sum of the network lanes receive power) of the Line Transceiver, read from the D… |
| 1.3.6.1.4.1.20044.107.3.3.208 | Tablepm100gemuxsfpMesrlineTxPwrMaxTable | not-accessible | current | List of pm100gemuxsfpMesrlineTxPwrMax Article |
| 1.3.6.1.4.1.20044.107.3.3.208.1 | Rowpm100gemuxsfpMesrlineTxPwrMaxEntry | not-accessible | current | Row definition for the pm100gemuxsfpMesrlineTxPwrMax table |
| 1.3.6.1.4.1.20044.107.3.3.208.1.1 | Columnpm100gemuxsfpMesrlineTxPwrMaxIndex | read-only | current | Index definition for the pm100gemuxsfpMesrlineTxPwrMax table |
| 1.3.6.1.4.1.20044.107.3.3.208.1.2 | Columnpm100gemuxsfpMesrlineTxPwrMaxPortn | read-only | current | Max Line Trscv Tx Power :This OID gives the maximum transmit power value among the network lanes of the Line Transceiver, read from the DDM (Digital Diagnostic… |
| 1.3.6.1.4.1.20044.107.3.3.224 | Tablepm100gemuxsfpMesrlineRxPwrMaxTable | not-accessible | current | List of pm100gemuxsfpMesrlineRxPwrMax Article |
| 1.3.6.1.4.1.20044.107.3.3.224.1 | Rowpm100gemuxsfpMesrlineRxPwrMaxEntry | not-accessible | current | Row definition for the pm100gemuxsfpMesrlineRxPwrMax table |
| 1.3.6.1.4.1.20044.107.3.3.224.1.1 | Columnpm100gemuxsfpMesrlineRxPwrMaxIndex | read-only | current | Index definition for the pm100gemuxsfpMesrlineRxPwrMax table |
| 1.3.6.1.4.1.20044.107.3.3.224.1.2 | Columnpm100gemuxsfpMesrlineRxPwrMaxPortn | read-only | current | Max Line Trscv Rx Power :This OID gives the maximum receive power value among the network lanes of the Line Transceiver, read in the DDM (Digital Diagnostic Mo… |
| 1.3.6.1.4.1.20044.107.3.3.492 | Scalarpm100gemuxsfpMesrlineTempMin | read-only | current | Min Line Trscv Temperature :This OID gives the minimum temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperatur… |
| 1.3.6.1.4.1.20044.107.3.3.496 | Scalarpm100gemuxsfpMesrlineTempMax | read-only | current | Max Line Trscv Temperature :This OID gives the maximum temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperatur… |
| 1.3.6.1.4.1.20044.107.4 | Nodepm100gemuxsfpcounters | |||
| 1.3.6.1.4.1.20044.107.4.1 | Nodepm100gemuxsfpCntOther | |||
| 1.3.6.1.4.1.20044.107.4.2 | Nodepm100gemuxsfpCntClient | |||
| 1.3.6.1.4.1.20044.107.4.2.112 | Tablepm100gemuxsfpCntclientInputErrorCounterTable | not-accessible | current | List of pm100gemuxsfpCntclientInputErrorCounter Article |
| 1.3.6.1.4.1.20044.107.4.2.112.1 | Rowpm100gemuxsfpCntclientInputErrorCounterEntry | not-accessible | current | Row definition for the pm100gemuxsfpCntclientInputErrorCounter table |
| 1.3.6.1.4.1.20044.107.4.2.112.1.1 | Columnpm100gemuxsfpCntclientInputErrorCounterIndex | read-only | current | Index definition for the pm100gemuxsfpCntclientInputErrorCounter table |
| 1.3.6.1.4.1.20044.107.4.2.112.1.2 | Columnpm100gemuxsfpCntclientInputErrorCounterValuePortn | read-only | current | Client Input Errors :This counter gives the number of SM-BIP8 (OTU4) or 66B/64B disparities (100GbE) on client port <Help> This counter gives the number of SM-… |
| 1.3.6.1.4.1.20044.107.4.2.112.1.3 | Columnpm100gemuxsfpCntclientInputErrorCounterErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the BIP8 error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.107.4.2.112.1.4 | Columnpm100gemuxsfpCntclientInputErrorCounterOverloadPortn | read-only | current | Client Counter Overload :This OID when set indicates a BIP8 error counter overload on Port |
| 1.3.6.1.4.1.20044.107.4.2.144 | Tablepm100gemuxsfpCntclientCbipCounterTable | not-accessible | current | List of pm100gemuxsfpCntclientCbipCounter Article |
| 1.3.6.1.4.1.20044.107.4.2.144.1 | Rowpm100gemuxsfpCntclientCbipCounterEntry | not-accessible | current | Row definition for the pm100gemuxsfpCntclientCbipCounter table |
| 1.3.6.1.4.1.20044.107.4.2.144.1.1 | Columnpm100gemuxsfpCntclientCbipCounterIndex | read-only | current | Index definition for the pm100gemuxsfpCntclientCbipCounter table |
| 1.3.6.1.4.1.20044.107.4.2.144.1.2 | Columnpm100gemuxsfpCntclientCbipCounterValuePortn | read-only | current | Client Output Errors :This counter gives the number of SM-BIP8 (OTU4) or 66B/64B disparities (100GbE) on client port <Help> This counter gives the number of SM… |
| 1.3.6.1.4.1.20044.107.4.2.144.1.3 | Columnpm100gemuxsfpCntclientCbipCounterErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the BIP8 error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.107.4.2.144.1.4 | Columnpm100gemuxsfpCntclientCbipCounterOverloadPortn | read-only | current | Client CBIP Counter Overload :This OID when set indicates a BIP8 error counter overload on Port |
| 1.3.6.1.4.1.20044.107.4.3 | Nodepm100gemuxsfpCntLine | |||
| 1.3.6.1.4.1.20044.107.4.3.192 | Tablepm100gemuxsfpCntlocalLineSmBip8ErrorCounterTable | not-accessible | current | List of pm100gemuxsfpCntlocalLineSmBip8ErrorCounter Article |
| 1.3.6.1.4.1.20044.107.4.3.192.1 | Rowpm100gemuxsfpCntlocalLineSmBip8ErrorCounterEntry | not-accessible | current | Row definition for the pm100gemuxsfpCntlocalLineSmBip8ErrorCounter table |
| 1.3.6.1.4.1.20044.107.4.3.192.1.1 | Columnpm100gemuxsfpCntlocalLineSmBip8ErrorCounterIndex | read-only | current | Index definition for the pm100gemuxsfpCntlocalLineSmBip8ErrorCounter table |
| 1.3.6.1.4.1.20044.107.4.3.192.1.2 | Columnpm100gemuxsfpCntlocalLineSmBip8ErrorCounterValuePortn | read-only | current | Uncorrected FEC Errors :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC <Help> This counter gives the current Bit Error Rate (resi… |
| 1.3.6.1.4.1.20044.107.4.3.192.1.3 | Columnpm100gemuxsfpCntlocalLineSmBip8ErrorCounterErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the B1 error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.107.4.3.192.1.4 | Columnpm100gemuxsfpCntlocalLineSmBip8ErrorCounterOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a B1 error counter overload on Port |
| 1.3.6.1.4.1.20044.107.4.3.193 | Tablepm100gemuxsfpCntlocalLineFecCorrectedErrorsCounterTable | not-accessible | current | List of pm100gemuxsfpCntlocalLineFecCorrectedErrorsCounter Article |
| 1.3.6.1.4.1.20044.107.4.3.193.1 | Rowpm100gemuxsfpCntlocalLineFecCorrectedErrorsCounterEntry | not-accessible | current | Row definition for the pm100gemuxsfpCntlocalLineFecCorrectedErrorsCounter table |
| 1.3.6.1.4.1.20044.107.4.3.193.1.1 | Columnpm100gemuxsfpCntlocalLineFecCorrectedErrorsCounterIndex | read-only | current | Index definition for the pm100gemuxsfpCntlocalLineFecCorrectedErrorsCounter table |
| 1.3.6.1.4.1.20044.107.4.3.193.1.2 | Columnpm100gemuxsfpCntlocalLineFecCorrectedErrorsCounterValuePortn | read-only | current | Line Input HD FEC Corrected Errors :This OID gives the current Bit Error Rate before the Hard Decision FEC <Help> This counter gives the current Bit Error Rate… |
| 1.3.6.1.4.1.20044.107.4.3.193.1.3 | Columnpm100gemuxsfpCntlocalLineFecCorrectedErrorsCounterErrorPortn | read-only | current | FEC Counter Error :This bit when set indicates the FEC corrected errors counter value is invalid on Line |
| 1.3.6.1.4.1.20044.107.4.3.193.1.4 | Columnpm100gemuxsfpCntlocalLineFecCorrectedErrorsCounterOverloadPortn | read-only | current | FEC Counter Overload :This bit when set indicates a FEC corrected errors counter overload on Line |
| 1.3.6.1.4.1.20044.107.4.3.194 | Tablepm100gemuxsfpCntremoteLineSmBip8ErrorCounterTable | not-accessible | current | List of pm100gemuxsfpCntremoteLineSmBip8ErrorCounter Article |
| 1.3.6.1.4.1.20044.107.4.3.194.1 | Rowpm100gemuxsfpCntremoteLineSmBip8ErrorCounterEntry | not-accessible | current | Row definition for the pm100gemuxsfpCntremoteLineSmBip8ErrorCounter table |
| 1.3.6.1.4.1.20044.107.4.3.194.1.1 | Columnpm100gemuxsfpCntremoteLineSmBip8ErrorCounterIndex | read-only | current | Index definition for the pm100gemuxsfpCntremoteLineSmBip8ErrorCounter table |
| 1.3.6.1.4.1.20044.107.4.3.194.1.2 | Columnpm100gemuxsfpCntremoteLineSmBip8ErrorCounterValuePortn | read-only | current | Remote SM BIP8 :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC on the remote side <Help> This counter gives the current Bit Error… |
| 1.3.6.1.4.1.20044.107.4.3.194.1.3 | Columnpm100gemuxsfpCntremoteLineSmBip8ErrorCounterErrorPortn | read-only | current | Remote Counter Error : |
| 1.3.6.1.4.1.20044.107.4.3.194.1.4 | Columnpm100gemuxsfpCntremoteLineSmBip8ErrorCounterOverloadPortn | read-only | current | Remote Counter Overload : |
| 1.3.6.1.4.1.20044.107.4.3.195 | Tablepm100gemuxsfpCntlineDfrmTimCntTable | not-accessible | current | List of pm100gemuxsfpCntlineDfrmTimCnt Article |
| 1.3.6.1.4.1.20044.107.4.3.195.1 | Rowpm100gemuxsfpCntlineDfrmTimCntEntry | not-accessible | current | Row definition for the pm100gemuxsfpCntlineDfrmTimCnt table |
| 1.3.6.1.4.1.20044.107.4.3.195.1.1 | Columnpm100gemuxsfpCntlineDfrmTimCntIndex | read-only | current | Index definition for the pm100gemuxsfpCntlineDfrmTimCnt table |
| 1.3.6.1.4.1.20044.107.4.3.195.1.2 | Columnpm100gemuxsfpCntlineDfrmTimCntValuePortn | read-only | current | Line Timer Counter : |
| 1.3.6.1.4.1.20044.107.4.3.195.1.3 | Columnpm100gemuxsfpCntlineDfrmTimCntErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.107.4.3.195.1.4 | Columnpm100gemuxsfpCntlineDfrmTimCntOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.107.4.3.196 | Tablepm100gemuxsfpCntlocalLineTrscvPreSdFecErrorCounterTable | not-accessible | current | List of pm100gemuxsfpCntlocalLineTrscvPreSdFecErrorCounter Article |
| 1.3.6.1.4.1.20044.107.4.3.196.1 | Rowpm100gemuxsfpCntlocalLineTrscvPreSdFecErrorCounterEntry | not-accessible | current | Row definition for the pm100gemuxsfpCntlocalLineTrscvPreSdFecErrorCounter table |
| 1.3.6.1.4.1.20044.107.4.3.196.1.1 | Columnpm100gemuxsfpCntlocalLineTrscvPreSdFecErrorCounterIndex | read-only | current | Index definition for the pm100gemuxsfpCntlocalLineTrscvPreSdFecErrorCounter table |
| 1.3.6.1.4.1.20044.107.4.3.196.1.2 | Columnpm100gemuxsfpCntlocalLineTrscvPreSdFecErrorCounterValuePortn | read-only | current | Pre FEC Errors :This OID gives the current Bit Error Rate before the FEC <Help> This counter gives the current Bit Error Rate before the FEC |
| 1.3.6.1.4.1.20044.107.4.3.196.1.3 | Columnpm100gemuxsfpCntlocalLineTrscvPreSdFecErrorCounterErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.107.4.3.196.1.4 | Columnpm100gemuxsfpCntlocalLineTrscvPreSdFecErrorCounterOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.107.4.3.197 | Tablepm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecErrorCounterTable | not-accessible | current | List of pm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecErrorCounter Article |
| 1.3.6.1.4.1.20044.107.4.3.197.1 | Rowpm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecErrorCounterEntry | not-accessible | current | Row definition for the pm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecErrorCounter table |
| 1.3.6.1.4.1.20044.107.4.3.197.1.1 | Columnpm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecErrorCounterIndex | read-only | current | Index definition for the pm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecErrorCounter table |
| 1.3.6.1.4.1.20044.107.4.3.197.1.2 | Columnpm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecErrorCounterValuePortn | read-only | current | Uncorrected FEC Errors :This OID gives the current Bit Error Rate after the Soft Decision FEC (residual) <Help> This counter gives the current Bit Error Rate a… |
| 1.3.6.1.4.1.20044.107.4.3.197.1.3 | Columnpm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecErrorCounterErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.107.4.3.197.1.4 | Columnpm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecErrorCounterOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.107.4.3.198 | Tablepm100gemuxsfpCntlocalLineTrscvPreSdFecBitCounterTable | not-accessible | current | List of pm100gemuxsfpCntlocalLineTrscvPreSdFecBitCounter Article |
| 1.3.6.1.4.1.20044.107.4.3.198.1 | Rowpm100gemuxsfpCntlocalLineTrscvPreSdFecBitCounterEntry | not-accessible | current | Row definition for the pm100gemuxsfpCntlocalLineTrscvPreSdFecBitCounter table |
| 1.3.6.1.4.1.20044.107.4.3.198.1.1 | Columnpm100gemuxsfpCntlocalLineTrscvPreSdFecBitCounterIndex | read-only | current | Index definition for the pm100gemuxsfpCntlocalLineTrscvPreSdFecBitCounter table |
| 1.3.6.1.4.1.20044.107.4.3.198.1.2 | Columnpm100gemuxsfpCntlocalLineTrscvPreSdFecBitCounterValuePortn | read-only | current | Pre-SD FEC Bit Counter :This OID gives the current Bit count before the Soft Decision FEC <Help> This counter gives the current Bit Count before the Soft Decis… |
| 1.3.6.1.4.1.20044.107.4.3.198.1.3 | Columnpm100gemuxsfpCntlocalLineTrscvPreSdFecBitCounterErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.107.4.3.198.1.4 | Columnpm100gemuxsfpCntlocalLineTrscvPreSdFecBitCounterOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.107.4.3.199 | Tablepm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecBitCounterTable | not-accessible | current | List of pm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecBitCounter Article |
| 1.3.6.1.4.1.20044.107.4.3.199.1 | Rowpm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecBitCounterEntry | not-accessible | current | Row definition for the pm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecBitCounter table |
| 1.3.6.1.4.1.20044.107.4.3.199.1.1 | Columnpm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecBitCounterIndex | read-only | current | Index definition for the pm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecBitCounter table |
| 1.3.6.1.4.1.20044.107.4.3.199.1.2 | Columnpm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecBitCounterValuePortn | read-only | current | Uncorrected SD FEC Bit Counter :This OID gives the current Bit count after the Soft Decision FEC (residual) <Help> This counter gives the current Bit Count aft… |
| 1.3.6.1.4.1.20044.107.4.3.199.1.3 | Columnpm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecBitCounterErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.107.4.3.199.1.4 | Columnpm100gemuxsfpCntlocalLineTrscvUncorrectedSdFecBitCounterOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.107.6 | Nodepm100gemuxsfpcontrolsWrite | |||
| 1.3.6.1.4.1.20044.107.6.1 | Nodepm100gemuxsfpCtrlOther | |||
| 1.3.6.1.4.1.20044.107.6.1.1 | Nodepm100gemuxsfpCtrlconfMgnt1 | |||
| 1.3.6.1.4.1.20044.107.6.1.1.1 | Scalarpm100gemuxsfpCtrlConf1Load1 | read-write | current | Load Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM. |
| 1.3.6.1.4.1.20044.107.6.1.1.2 | Scalarpm100gemuxsfpCtrlConf2Load1 | read-write | current | Load Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM. |
| 1.3.6.1.4.1.20044.107.6.1.1.10 | Scalarpm100gemuxsfpCtrlConf2Flash1 | read-write | current | Write Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura… |
| 1.3.6.1.4.1.20044.107.6.1.1.14 | Scalarpm100gemuxsfpCtrlConf2Clear1 | read-write | current | Clear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o… |
| 1.3.6.1.4.1.20044.107.6.1.4 | Nodepm100gemuxsfpCtrlsynth4 | |||
| 1.3.6.1.4.1.20044.107.6.1.4.1 | Scalarpm100gemuxsfpCtrlCorrelatOn | read-write | current | Enable Alarm Correlation :This OID enables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.107.6.1.4.2 | Scalarpm100gemuxsfpCtrlCorrelatOff | read-write | current | Disable Alarm Correlation :This OID disables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.107.6.1.5 | Nodepm100gemuxsfpCtrlswMgnt | |||
| 1.3.6.1.4.1.20044.107.6.1.5.2 | Scalarpm100gemuxsfpCtrlColdReset | read-write | current | PM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> … |
| 1.3.6.1.4.1.20044.107.6.1.5.3 | Scalarpm100gemuxsfpCtrlWarmReset | read-write | current | PM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th… |
| 1.3.6.1.4.1.20044.107.6.1.5.5 | Scalarpm100gemuxsfpCtrlLoadSwBank1 | read-write | current | Set Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW… |
| 1.3.6.1.4.1.20044.107.6.1.5.6 | Scalarpm100gemuxsfpCtrlLoadSwBank2 | read-write | current | Set Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S… |
| 1.3.6.1.4.1.20044.107.6.1.6 | Nodepm100gemuxsfpCtrlgwMgnt | |||
| 1.3.6.1.4.1.20044.107.6.1.6.1 | Scalarpm100gemuxsfpCtrlCurrentGwReset | read-write | current | Active Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting. |
| 1.3.6.1.4.1.20044.107.6.1.6.5 | Scalarpm100gemuxsfpCtrlLoadGwBank1 | read-write | current | Set Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.107.6.1.6.6 | Scalarpm100gemuxsfpCtrlLoadGwBank2 | read-write | current | Set Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.107.6.1.6.7 | Scalarpm100gemuxsfpCtrlLoadGwBank3 | read-write | current | Set Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.107.6.1.6.8 | Scalarpm100gemuxsfpCtrlLoadGwBank4 | read-write | current | Set Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.107.6.1.192 | Nodepm100gemuxsfpCtrlledTest | |||
| 1.3.6.1.4.1.20044.107.6.1.192.1 | Scalarpm100gemuxsfpCtrlGreenLed | read-write | current | Green Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green |
| 1.3.6.1.4.1.20044.107.6.1.192.2 | Scalarpm100gemuxsfpCtrlRedLed | read-write | current | Red Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red |
| 1.3.6.1.4.1.20044.107.6.1.192.3 | Scalarpm100gemuxsfpCtrlLedOff | read-write | current | Leds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF |
| 1.3.6.1.4.1.20044.107.6.1.201 | Nodepm100gemuxsfpCtrlinitSwitchMarvell | |||
| 1.3.6.1.4.1.20044.107.6.1.201.1 | Scalarpm100gemuxsfpCtrlInitSwitchMarvell | read-write | current | Switch Initialization :This OID operates an initialization of the switch managed through the module <Help> This control activates an initialization of the swit… |
| 1.3.6.1.4.1.20044.107.6.1.259 | Nodepm100gemuxsfpCtrlresetCount | |||
| 1.3.6.1.4.1.20044.107.6.1.259.1 | Scalarpm100gemuxsfpCtrlResetcount | read-write | current | Module Count Global Reset :This OID resets all the errors counters on the module <Help > This control initiates a reset of the errors counters on the module |
| 1.3.6.1.4.1.20044.107.6.1.260 | Nodepm100gemuxsfpCtrlresetRmon | |||
| 1.3.6.1.4.1.20044.107.6.1.260.1 | Scalarpm100gemuxsfpCtrlResetrmon | read-write | current | Module Rmon Global Reset :This OID resets all the Rmon counters on the module <Help > This control initiates a reset of the Rmon counters on the module |
| 1.3.6.1.4.1.20044.107.6.1.261 | Nodepm100gemuxsfpCtrlresetMeasurements | |||
| 1.3.6.1.4.1.20044.107.6.1.261.1 | Scalarpm100gemuxsfpCtrlResetmeasurements | read-write | current | Management Meas Global Reset :This OID resets some measurements on the management <Help > This control initiates a reset of some measurements on the management |
| 1.3.6.1.4.1.20044.107.6.2 | Nodepm100gemuxsfpCtrlClient | |||
| 1.3.6.1.4.1.20044.107.6.2.16 | Tablepm100gemuxsfpCtrlaccessLoopTable | not-accessible | current | List of pm100gemuxsfpCtrlaccessLoop Article |
| 1.3.6.1.4.1.20044.107.6.2.16.1 | Rowpm100gemuxsfpCtrlaccessLoopEntry | not-accessible | current | Row definition for the pm100gemuxsfpCtrlaccessLoop table |
| 1.3.6.1.4.1.20044.107.6.2.16.1.1 | Columnpm100gemuxsfpCtrlaccessLoopIndex | read-only | current | Index definition for the pm100gemuxsfpCtrlaccessLoop table |
| 1.3.6.1.4.1.20044.107.6.2.16.1.2 | Columnpm100gemuxsfpCtrlaccessLoopPortn | read-write | current | Client Facility Loopback :This OID, when set at '1' puts the client port in loopback, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. <Help… |
| 1.3.6.1.4.1.20044.107.6.2.17 | Tablepm100gemuxsfpCtrlclientLoopToLineTable | not-accessible | current | List of pm100gemuxsfpCtrlclientLoopToLine Article |
| 1.3.6.1.4.1.20044.107.6.2.17.1 | Rowpm100gemuxsfpCtrlclientLoopToLineEntry | not-accessible | current | Row definition for the pm100gemuxsfpCtrlclientLoopToLine table |
| 1.3.6.1.4.1.20044.107.6.2.17.1.1 | Columnpm100gemuxsfpCtrlclientLoopToLineIndex | read-only | current | Index definition for the pm100gemuxsfpCtrlclientLoopToLine table |
| 1.3.6.1.4.1.20044.107.6.2.17.1.2 | Columnpm100gemuxsfpCtrlclientLoopToLinePortn | read-write | current | Client Terminal Loopback :This OID, when set, puts the client port in loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.<Help> This control ena… |
| 1.3.6.1.4.1.20044.107.6.2.21 | Tablepm100gemuxsfpCtrlcsfUpInsTable | not-accessible | current | List of pm100gemuxsfpCtrlcsfUpIns Article |
| 1.3.6.1.4.1.20044.107.6.2.21.1 | Rowpm100gemuxsfpCtrlcsfUpInsEntry | not-accessible | current | Row definition for the pm100gemuxsfpCtrlcsfUpIns table |
| 1.3.6.1.4.1.20044.107.6.2.21.1.1 | Columnpm100gemuxsfpCtrlcsfUpInsIndex | read-only | current | Index definition for the pm100gemuxsfpCtrlcsfUpIns table |
| 1.3.6.1.4.1.20044.107.6.2.21.1.2 | Columnpm100gemuxsfpCtrlcsfUpInsPortn | read-write | current | Client Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo… |
| 1.3.6.1.4.1.20044.107.6.2.22 | Tablepm100gemuxsfpCtrlcaisDwInsTable | not-accessible | current | List of pm100gemuxsfpCtrlcaisDwIns Article |
| 1.3.6.1.4.1.20044.107.6.2.22.1 | Rowpm100gemuxsfpCtrlcaisDwInsEntry | not-accessible | current | Row definition for the pm100gemuxsfpCtrlcaisDwIns table |
| 1.3.6.1.4.1.20044.107.6.2.22.1.1 | Columnpm100gemuxsfpCtrlcaisDwInsIndex | read-only | current | Index definition for the pm100gemuxsfpCtrlcaisDwIns table |
| 1.3.6.1.4.1.20044.107.6.2.22.1.2 | Columnpm100gemuxsfpCtrlcaisDwInsPortn | read-write | current | Client AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port |
| 1.3.6.1.4.1.20044.107.6.2.262 | Tablepm100gemuxsfpCtrlclientResetAllCountTable | not-accessible | current | List of pm100gemuxsfpCtrlclientResetAllCount Article |
| 1.3.6.1.4.1.20044.107.6.2.262.1 | Rowpm100gemuxsfpCtrlclientResetAllCountEntry | not-accessible | current | Row definition for the pm100gemuxsfpCtrlclientResetAllCount table |
| 1.3.6.1.4.1.20044.107.6.2.262.1.1 | Columnpm100gemuxsfpCtrlclientResetAllCountIndex | read-only | current | Index definition for the pm100gemuxsfpCtrlclientResetAllCount table |
| 1.3.6.1.4.1.20044.107.6.2.262.1.2 | Columnpm100gemuxsfpCtrlclientResetAllCountsPortn | read-write | current | Client Counters Reset :This OID resets every counter on the client port <Help> This control operates a reset on the statistics current ,previous and history cl… |
| 1.3.6.1.4.1.20044.107.6.3 | Nodepm100gemuxsfpCtrlLine | |||
| 1.3.6.1.4.1.20044.107.6.3.64 | Tablepm100gemuxsfpCtrlcommAccessLoopTable | not-accessible | current | List of pm100gemuxsfpCtrlcommAccessLoop Article |
| 1.3.6.1.4.1.20044.107.6.3.64.1 | Rowpm100gemuxsfpCtrlcommAccessLoopEntry | not-accessible | current | Row definition for the pm100gemuxsfpCtrlcommAccessLoop table |
| 1.3.6.1.4.1.20044.107.6.3.64.1.1 | Columnpm100gemuxsfpCtrlcommAccessLoopIndex | read-only | current | Index definition for the pm100gemuxsfpCtrlcommAccessLoop table |
| 1.3.6.1.4.1.20044.107.6.3.64.1.2 | Columnpm100gemuxsfpCtrlcommAccessLoopPortn | read-write | current | Line Terminal Loopback :This OID, when set, puts the module in common access loop back, looping the 200 Gb/s output signal on the 200 Gb/s input.<Help> This co… |
| 1.3.6.1.4.1.20044.107.6.3.66 | Tablepm100gemuxsfpCtrllineLoopTable | not-accessible | current | List of pm100gemuxsfpCtrllineLoop Article |
| 1.3.6.1.4.1.20044.107.6.3.66.1 | Rowpm100gemuxsfpCtrllineLoopEntry | not-accessible | current | Row definition for the pm100gemuxsfpCtrllineLoop table |
| 1.3.6.1.4.1.20044.107.6.3.66.1.1 | Columnpm100gemuxsfpCtrllineLoopIndex | read-only | current | Index definition for the pm100gemuxsfpCtrllineLoop table |
| 1.3.6.1.4.1.20044.107.6.3.66.1.2 | Columnpm100gemuxsfpCtrllineLoopPortn | read-write | current | Line Facility Loopback :This OID, when set at '1' puts the module in line loopback mode, looping the received 200 Gb/s signal on the transmit 200 Gb/s output. … |
| 1.3.6.1.4.1.20044.107.6.3.69 | Tablepm100gemuxsfpCtrlfecDisableTable | not-accessible | current | List of pm100gemuxsfpCtrlfecDisable Article |
| 1.3.6.1.4.1.20044.107.6.3.69.1 | Rowpm100gemuxsfpCtrlfecDisableEntry | not-accessible | current | Row definition for the pm100gemuxsfpCtrlfecDisable table |
| 1.3.6.1.4.1.20044.107.6.3.69.1.1 | Columnpm100gemuxsfpCtrlfecDisableIndex | read-only | current | Index definition for the pm100gemuxsfpCtrlfecDisable table |
| 1.3.6.1.4.1.20044.107.6.3.69.1.2 | Columnpm100gemuxsfpCtrlfecDisablePortn | read-write | current | Forward Error Correction Inhibition :This OID, when set, inhibits the Forward Error Correction feature on the line input <Help> This control enables/disables t… |
| 1.3.6.1.4.1.20044.107.6.3.209 | Tablepm100gemuxsfpCtrlmsaLineLoopTable | not-accessible | current | List of pm100gemuxsfpCtrlmsaLineLoop Article |
| 1.3.6.1.4.1.20044.107.6.3.209.1 | Rowpm100gemuxsfpCtrlmsaLineLoopEntry | not-accessible | current | Row definition for the pm100gemuxsfpCtrlmsaLineLoop table |
| 1.3.6.1.4.1.20044.107.6.3.209.1.1 | Columnpm100gemuxsfpCtrlmsaLineLoopIndex | read-only | current | Index definition for the pm100gemuxsfpCtrlmsaLineLoop table |
| 1.3.6.1.4.1.20044.107.6.3.209.1.2 | Columnpm100gemuxsfpCtrlmsaLineLoopPortn | read-write | current | MSA Line Loop :This OID operates a line loopback on the MSA Line <Help> This control defines the line loop back of the line transceiver |
| 1.3.6.1.4.1.20044.107.6.3.210 | Tablepm100gemuxsfpCtrlmsaRestartTable | not-accessible | current | List of pm100gemuxsfpCtrlmsaRestart Article |
| 1.3.6.1.4.1.20044.107.6.3.210.1 | Rowpm100gemuxsfpCtrlmsaRestartEntry | not-accessible | current | Row definition for the pm100gemuxsfpCtrlmsaRestart table |
| 1.3.6.1.4.1.20044.107.6.3.210.1.1 | Columnpm100gemuxsfpCtrlmsaRestartIndex | read-only | current | Index definition for the pm100gemuxsfpCtrlmsaRestart table |
| 1.3.6.1.4.1.20044.107.6.3.210.1.2 | Columnpm100gemuxsfpCtrlmsaRestartPortn | read-write | current | Line MSA Restart :This OID tentatively restart the MSA line module <Help > This control initiates a restart of the MSA |
| 1.3.6.1.4.1.20044.107.6.3.221 | Tablepm100gemuxsfpCtrlforceKeyExchangeTable | not-accessible | deprecated | List of pm100gemuxsfpCtrlforceKeyExchange Article |
| 1.3.6.1.4.1.20044.107.6.3.221.1 | Rowpm100gemuxsfpCtrlforceKeyExchangeEntry | not-accessible | deprecated | Row definition for the pm100gemuxsfpCtrlforceKeyExchange table |
| 1.3.6.1.4.1.20044.107.6.3.221.1.1 | Columnpm100gemuxsfpCtrlforceKeyExchangeIndex | read-only | deprecated | Index definition for the pm100gemuxsfpCtrlforceKeyExchange table |
| 1.3.6.1.4.1.20044.107.6.3.221.1.2 | Columnpm100gemuxsfpCtrlforceKeyExchangePortn | read-write | deprecated | : |
| 1.3.6.1.4.1.20044.107.6.3.222 | Tablepm100gemuxsfpCtrldisableEncryptionTable | not-accessible | deprecated | List of pm100gemuxsfpCtrldisableEncryption Article |
| 1.3.6.1.4.1.20044.107.6.3.222.1 | Rowpm100gemuxsfpCtrldisableEncryptionEntry | not-accessible | deprecated | Row definition for the pm100gemuxsfpCtrldisableEncryption table |
| 1.3.6.1.4.1.20044.107.6.3.222.1.1 | Columnpm100gemuxsfpCtrldisableEncryptionIndex | read-only | deprecated | Index definition for the pm100gemuxsfpCtrldisableEncryption table |
| 1.3.6.1.4.1.20044.107.6.3.222.1.2 | Columnpm100gemuxsfpCtrldisableEncryptionPortn | read-write | deprecated | : |
| 1.3.6.1.4.1.20044.107.6.3.223 | Tablepm100gemuxsfpCtrlresetMonitoringTable | not-accessible | deprecated | List of pm100gemuxsfpCtrlresetMonitoring Article |
| 1.3.6.1.4.1.20044.107.6.3.223.1 | Rowpm100gemuxsfpCtrlresetMonitoringEntry | not-accessible | deprecated | Row definition for the pm100gemuxsfpCtrlresetMonitoring table |
| 1.3.6.1.4.1.20044.107.6.3.223.1.1 | Columnpm100gemuxsfpCtrlresetMonitoringIndex | read-only | deprecated | Index definition for the pm100gemuxsfpCtrlresetMonitoring table |
| 1.3.6.1.4.1.20044.107.6.3.223.1.2 | Columnpm100gemuxsfpCtrlresetMonitoringPortn | read-write | deprecated | : |
| 1.3.6.1.4.1.20044.107.6.3.263 | Tablepm100gemuxsfpCtrllineResetAllCountTable | not-accessible | current | List of pm100gemuxsfpCtrllineResetAllCount Article |
| 1.3.6.1.4.1.20044.107.6.3.263.1 | Rowpm100gemuxsfpCtrllineResetAllCountEntry | not-accessible | current | Row definition for the pm100gemuxsfpCtrllineResetAllCount table |
| 1.3.6.1.4.1.20044.107.6.3.263.1.1 | Columnpm100gemuxsfpCtrllineResetAllCountIndex | read-only | current | Index definition for the pm100gemuxsfpCtrllineResetAllCount table |
| 1.3.6.1.4.1.20044.107.6.3.263.1.2 | Columnpm100gemuxsfpCtrllineResetAllCountsPortn | read-write | current | Line Counters Reset :This OID resets every counter on the line port <Help> This control operates a reset on the statistics current ,previous and history line p… |
| 1.3.6.1.4.1.20044.107.7 | Nodepm100gemuxsfpri | |||
| 1.3.6.1.4.1.20044.107.7.1 | Nodepm100gemuxsfpriTable | |||
| 1.3.6.1.4.1.20044.107.7.1.1 | Tablepm100gemuxsfpRinvSfpTable | not-accessible | current | List of the SFPs on the selected module |
| 1.3.6.1.4.1.20044.107.7.1.1.1 | Rowpm100gemuxsfpRinvSfpEntry | not-accessible | current | Row definition for the SFP table |
| 1.3.6.1.4.1.20044.107.7.1.1.1.1 | Columnpm100gemuxsfpRinvSfpIndex | read-only | current | Index for SFP table |
| 1.3.6.1.4.1.20044.107.7.1.1.1.2 | Columnpm100gemuxsfpRinvsfp | read-only | current | Inventory for the SFP: This OID contains the inventory for the SFP |
| 1.3.6.1.4.1.20044.107.7.1.2 | Tablepm100gemuxsfpRinvLineTable | not-accessible | current | List of the XFPs on the selected module |
| 1.3.6.1.4.1.20044.107.7.1.2.1 | Rowpm100gemuxsfpRinvLineEntry | not-accessible | current | Row definition for the XFP table |
| 1.3.6.1.4.1.20044.107.7.1.2.1.1 | Columnpm100gemuxsfpRinvLineIndex | read-only | current | Index for XFP table |
| 1.3.6.1.4.1.20044.107.7.1.2.1.2 | Columnpm100gemuxsfpRinvxfpLine | read-only | current | Inventory for the XFP: This OID contains the inventory for the XFP |
| 1.3.6.1.4.1.20044.107.7.2 | Scalarpm100gemuxsfpRinvReloadInventory | read-write | current | Reload the inventory: This OID triggers an inventory reload. |
| 1.3.6.1.4.1.20044.107.7.3 | Scalarpm100gemuxsfpRinvHwPlatform | read-only | current | HW platform description: This OID contains the description of the Hardware platform. |
| 1.3.6.1.4.1.20044.107.7.4 | Scalarpm100gemuxsfpRinvModulePlatform | read-only | current | Module platform description: This OID contains the description of the Module. |
| 1.3.6.1.4.1.20044.107.7.5 | Scalarpm100gemuxsfpRinvSwPlatform | read-only | current | SW platform description: This OID contains the description of the Software platform. |
| 1.3.6.1.4.1.20044.107.7.6 | Scalarpm100gemuxsfpRinvGwPlatform | read-only | current | GW platform description: This OID contains the description of the Gateware platform. |
| 1.3.6.1.4.1.20044.107.8 | Nodepm100gemuxsfpdownload | |||
| 1.3.6.1.4.1.20044.107.8.1 | Nodepm100gemuxsfpDwlOther | |||
| 1.3.6.1.4.1.20044.107.8.1.0 | Nodepm100gemuxsfpDwlrestartProcess | |||
| 1.3.6.1.4.1.20044.107.8.1.0.1 | Scalarpm100gemuxsfpDwlWarmRestartProcessed | read-only | current | Warm Restart :This OID indicates that the module last restart was a Warm RESTART |
| 1.3.6.1.4.1.20044.107.8.1.0.2 | Scalarpm100gemuxsfpDwlColdRestartProcessed | read-only | current | Cold Restart :This OID indicates that the module last restart was a Cold RESTART |
| 1.3.6.1.4.1.20044.107.8.1.1 | Nodepm100gemuxsfpDwlswBanksUsed | |||
| 1.3.6.1.4.1.20044.107.8.1.1.1 | Scalarpm100gemuxsfpDwlSwBank1Used | read-only | current | SW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.107.8.1.1.2 | Scalarpm100gemuxsfpDwlSwBank2Used | read-only | current | SW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby |
| 1.3.6.1.4.1.20044.107.8.1.1.5 | Scalarpm100gemuxsfpDwlSwBank1Notempty | read-only | current | SW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package |
| 1.3.6.1.4.1.20044.107.8.1.1.6 | Scalarpm100gemuxsfpDwlSwBank2Notempty | read-only | current | SW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package |
| 1.3.6.1.4.1.20044.107.8.1.2 | Nodepm100gemuxsfpDwlgwBanksUsed | |||
| 1.3.6.1.4.1.20044.107.8.1.2.1 | Scalarpm100gemuxsfpDwlGwBank1Used | read-only | current | GW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.107.8.1.2.2 | Scalarpm100gemuxsfpDwlGwBank2Used | read-only | current | GW bank 2 active :This OID indicates the module is working on GW bank 2 |
| 1.3.6.1.4.1.20044.107.8.1.2.3 | Scalarpm100gemuxsfpDwlGwBank3Used | read-only | current | GW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby |
| 1.3.6.1.4.1.20044.107.8.1.2.4 | Scalarpm100gemuxsfpDwlGwBank4Used | read-only | current | GW bank 4 active :This OID indicates the module is working on GW bank 4 |
| 1.3.6.1.4.1.20044.107.8.1.2.5 | Scalarpm100gemuxsfpDwlGwBank1Notempty | read-only | current | GW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package |
| 1.3.6.1.4.1.20044.107.8.1.2.6 | Scalarpm100gemuxsfpDwlGwBank2Notempty | read-only | current | GW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2 |
| 1.3.6.1.4.1.20044.107.8.1.2.7 | Scalarpm100gemuxsfpDwlGwBank3Notempty | read-only | current | GW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package |
| 1.3.6.1.4.1.20044.107.8.1.2.8 | Scalarpm100gemuxsfpDwlGwBank4Notempty | read-only | current | GW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4 |
| 1.3.6.1.4.1.20044.107.8.2 | Nodepm100gemuxsfpDwlClient | |||
| 1.3.6.1.4.1.20044.107.8.3 | Nodepm100gemuxsfpDwlLine | |||
| 1.3.6.1.4.1.20044.107.9 | Nodepm100gemuxsfpConfig | |||
| 1.3.6.1.4.1.20044.107.9.1 | Nodepm100gemuxsfpCfgAccessCAisCsf | |||
| 1.3.6.1.4.1.20044.107.9.1.1 | Tablepm100gemuxsfpCfgClientcaiscsfTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.107.9.1.1.1 | Rowpm100gemuxsfpCfgClientcaiscsfEntry | not-accessible | current | Row definition for the accessCAisCsf table |
| 1.3.6.1.4.1.20044.107.9.1.1.1.1 | Columnpm100gemuxsfpCfgClientcaiscsfIndex | read-only | current | Index definition for the clientcaiscsf table |
| 1.3.6.1.4.1.20044.107.9.1.1.1.3 | Columnpm100gemuxsfpCfgReservePortn | read-write | current | CAIS mode on Client Port :This register enables/disables port laser shutdown on CAIS insertion condition |
| 1.3.6.1.4.1.20044.107.9.2 | Nodepm100gemuxsfpCfgStartup | |||
| 1.3.6.1.4.1.20044.107.9.2.1 | Tablepm100gemuxsfpCfgClientStartupTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.107.9.2.1.1 | Rowpm100gemuxsfpCfgClientStartupEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.107.9.2.1.1.1 | Columnpm100gemuxsfpCfgClientStartupIndex | read-only | current | Index definition for the clientStartup table |
| 1.3.6.1.4.1.20044.107.9.2.1.1.3 | Columnpm100gemuxsfpCfgSystConfPortPortn | read-write | current | Default Settings on Client Port :This register configures the default initialisation settings on the port. |
| 1.3.6.1.4.1.20044.107.9.2.1.1.4 | Columnpm100gemuxsfpCfgNetConfPortPortn | read-write | current | Default Settings on Client Port :This register configures the default initialisation settings on the port. |
| 1.3.6.1.4.1.20044.107.9.2.1.1.14 | Columnpm100gemuxsfpCfgOptionsPortPortn | read-write | current | Default Options on Client Port :This register configures the default options on the port. |
| 1.3.6.1.4.1.20044.107.9.2.2 | Tablepm100gemuxsfpCfgLineStartupTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.107.9.2.2.1 | Rowpm100gemuxsfpCfgLineStartupEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.107.9.2.2.1.1 | Columnpm100gemuxsfpCfgLineStartupIndex | read-only | current | Index definition for the lineStartup table |
| 1.3.6.1.4.1.20044.107.9.2.2.1.3 | Columnpm100gemuxsfpCfgSystConfLinePortn | read-write | current | Default Settings on Line :This register configures the default initialisation settings on Line |
| 1.3.6.1.4.1.20044.107.9.2.2.1.14 | Columnpm100gemuxsfpCfgOptionsLinePortn | read-write | current | Default Options on Line :This register configures the default options on the line |
| 1.3.6.1.4.1.20044.107.9.2.3 | Tablepm100gemuxsfpCfgXfpTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.107.9.2.3.1 | Rowpm100gemuxsfpCfgXfpEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.107.9.2.3.1.1 | Columnpm100gemuxsfpCfgXfpIndex | read-only | current | Index definition for the xfp table |
| 1.3.6.1.4.1.20044.107.9.2.3.1.3 | Columnpm100gemuxsfpCfgSystConfMsaLinePortn | read-write | current | Default settings on TRX :This register configures the default initialisation settings on TRX |
| 1.3.6.1.4.1.20044.107.9.2.3.1.6 | Columnpm100gemuxsfpCfgLineInputPowerHighAlarmPortn | read-write | deprecated | Default settings on alarm threshold :This register configures the default initialisation settings on a threshold |
| 1.3.6.1.4.1.20044.107.9.2.3.1.7 | Columnpm100gemuxsfpCfgLineInputPowerHighWarningPortn | read-write | deprecated | Default settings on warning threshold :This register configures the default initialisation settings on a threshold |
| 1.3.6.1.4.1.20044.107.9.2.3.1.8 | Columnpm100gemuxsfpCfgLineInputPowerLowWarningPortn | read-write | deprecated | Default settings on warning threshold :This register configures the default initialisation settings on a threshold |
| 1.3.6.1.4.1.20044.107.9.2.3.1.9 | Columnpm100gemuxsfpCfgLineInputPowerLowAlarmPortn | read-write | deprecated | Default settings on alarm threshold :This register configures the default initialisation settings on a threshold |
| 1.3.6.1.4.1.20044.107.9.2.3.1.10 | Columnpm100gemuxsfpCfgLineOutputPowerHighAlarmPortn | read-write | deprecated | Default settings on alarm threshold :This register configures the default initialisation settings on a threshold |
| 1.3.6.1.4.1.20044.107.9.2.3.1.11 | Columnpm100gemuxsfpCfgLineOutputPowerHighWarningPortn | read-write | deprecated | Default settings on warning threshold :This register configures the default initialisation settings on a threshold |
| 1.3.6.1.4.1.20044.107.9.2.3.1.12 | Columnpm100gemuxsfpCfgLineOutputPowerLowWarningPortn | read-write | deprecated | Default settings on warning threshold :This register configures the default initialisation settings on a threshold |
| 1.3.6.1.4.1.20044.107.9.2.3.1.13 | Columnpm100gemuxsfpCfgLineOutputPowerLowAlarmPortn | read-write | deprecated | Default settings on alarm threshold :This register configures the default initialisation settings on a threshold |
| 1.3.6.1.4.1.20044.107.9.2.3.1.14 | Columnpm100gemuxsfpCfgLineLossOfSignalPortn | read-write | deprecated | Default settings on Los threshold :This register configures the default initialisation settings on a threshold |
| 1.3.6.1.4.1.20044.107.9.2.4 | Tablepm100gemuxsfpCfgClientOtxtlhTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.107.9.2.4.1 | Rowpm100gemuxsfpCfgClientOtxtlhEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.107.9.2.4.1.1 | Columnpm100gemuxsfpCfgClientOtxtlhIndex | read-only | current | Index definition for the clientOtxtlh table |
| 1.3.6.1.4.1.20044.107.9.2.4.1.3 | Columnpm100gemuxsfpCfgControlsPortn | read-write | deprecated | Defaut Client settings :This register configures the start-up settings on the ports |
| 1.3.6.1.4.1.20044.107.9.2.4.1.6 | Columnpm100gemuxsfpCfgClientPwrLaserPortn | read-write | current | Defaut Client output Power :This register configures the start-up output power of the client transceiver (Unit = dBm) |
| 1.3.6.1.4.1.20044.107.9.2.4.1.7 | Columnpm100gemuxsfpCfgClientFCurrentPortn | read-write | current | Default Client transceiver Channel :This register configures the start-up laser channel of the client transceiver |
| 1.3.6.1.4.1.20044.107.9.2.4.1.8 | Columnpm100gemuxsfpCfgClientGridCurrentPortn | read-write | current | Default Client transceiver Grid :This register configures the start-up laser grid of the client transceiver |
| 1.3.6.1.4.1.20044.107.9.2.4.1.9 | Columnpm100gemuxsfpCfgClientFoPortn | read-write | current | Default Client first Frequency :This register configures the start-up first frequency of the client transceiver |
| 1.3.6.1.4.1.20044.107.9.3 | Nodepm100gemuxsfpCfgLabels | |||
| 1.3.6.1.4.1.20044.107.9.3.1 | Tablepm100gemuxsfpCfgLabelclientTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.107.9.3.1.1 | Rowpm100gemuxsfpCfgLabelclientEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.107.9.3.1.1.1 | Columnpm100gemuxsfpCfgLabelclientIndex | read-only | current | Index definition for the labelclient table |
| 1.3.6.1.4.1.20044.107.9.3.1.1.3 | Columnpm100gemuxsfpCfgLabelclientPortn | read-write | current | Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. |
| 1.3.6.1.4.1.20044.107.9.3.2 | Tablepm100gemuxsfpCfgLabellineTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.107.9.3.2.1 | Rowpm100gemuxsfpCfgLabellineEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.107.9.3.2.1.1 | Columnpm100gemuxsfpCfgLabellineIndex | read-only | current | Index definition for the labelline table |
| 1.3.6.1.4.1.20044.107.9.3.2.1.3 | Columnpm100gemuxsfpCfgLabellinePortn | read-write | current | Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. |
| 1.3.6.1.4.1.20044.107.9.4 | Nodepm100gemuxsfpCfgStartuptlh | |||
| 1.3.6.1.4.1.20044.107.9.4.1 | Tablepm100gemuxsfpCfgOtxtlhTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.107.9.4.1.1 | Rowpm100gemuxsfpCfgOtxtlhEntry | not-accessible | current | Row definition for the startuptlh table |
| 1.3.6.1.4.1.20044.107.9.4.1.1.1 | Columnpm100gemuxsfpCfgOtxtlhIndex | read-only | current | Index definition for the otxtlh table |
| 1.3.6.1.4.1.20044.107.9.4.1.1.6 | Columnpm100gemuxsfpCfgLinePwrLaserPortn | read-write | deprecated | Defaut Line output Power :This register configures the start-up output power of the Line tranceiver (Unit = dBm) |
| 1.3.6.1.4.1.20044.107.9.4.1.1.7 | Columnpm100gemuxsfpCfgLineFCurrentPortn | read-write | deprecated | Default Line transceiver Tx Channel :This register configures the start-up laser channel of the Line Tx transceiver |
| 1.3.6.1.4.1.20044.107.9.4.1.1.8 | Columnpm100gemuxsfpCfgLineGridCurrentPortn | read-write | deprecated | Default Line transceiver Grid :This register configures the start-up laser grid of the Line transceiver |
| 1.3.6.1.4.1.20044.107.9.4.1.1.9 | Columnpm100gemuxsfpCfgFPortn | read-write | deprecated | Default Line TRX lowest Freq :This register configures the start-up lowest frequency of the Line transceiver |
| 1.3.6.1.4.1.20044.107.9.4.1.1.10 | Columnpm100gemuxsfpCfgRxLineFCurrentPortn | read-write | deprecated | Default Line transceiver Rx Channel :This register configures the start-up laser channel of the Line Rx transceiver |
| 1.3.6.1.4.1.20044.107.9.5 | Nodepm100gemuxsfpCfgOther | |||
| 1.3.6.1.4.1.20044.107.9.5.1 | Nodepm100gemuxsfptablemoduleOther | |||
| 1.3.6.1.4.1.20044.107.9.5.1.5 | Scalarpm100gemuxsfpCfgmoduleMode | read-write | current | Default settings on Module :This register selects the configuration mode of the module |
| 1.3.6.1.4.1.20044.107.9.6 | Nodepm100gemuxsfpCfgStartuptablefive | |||
| 1.3.6.1.4.1.20044.107.9.6.1 | Tablepm100gemuxsfpCfgOtxtlhcapabilitiesTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.107.9.6.1.1 | Rowpm100gemuxsfpCfgOtxtlhcapabilitiesEntry | not-accessible | current | Row definition for the startuptablefive table |
| 1.3.6.1.4.1.20044.107.9.6.1.1.1 | Columnpm100gemuxsfpCfgOtxtlhcapabilitiesIndex | read-only | current | Index definition for the otxtlhcapabilities table |
| 1.3.6.1.4.1.20044.107.9.6.1.1.3 | Columnpm100gemuxsfpCfgComponentTypePortn | read-only | current | Component parameters :This OID defines the component parameters |
| 1.3.6.1.4.1.20044.107.9.6.1.1.4 | Columnpm100gemuxsfpCfgMiscellaneousPortn | read-only | current | Miscellaneous default settings :This OID defines the miscellaneous parameters |
| 1.3.6.1.4.1.20044.107.9.6.1.1.5 | Columnpm100gemuxsfpCfgFirstChannelPortn | read-only | current | Number of the first channel of the component :This OID defines the first channel number of the PM |
| 1.3.6.1.4.1.20044.107.9.6.1.1.6 | Columnpm100gemuxsfpCfgLastChannelPortn | read-only | current | Number of the last channel of the component :This OID defines the last channel number of the PM |
| 1.3.6.1.4.1.20044.107.9.6.1.1.7 | Columnpm100gemuxsfpCfgGridPortn | read-only | current | Grid value of the component :This OID defines the grid of the PM |
| 1.3.6.1.4.1.20044.107.9.257 | Scalarpm100gemuxsfpCfgWriteConfiguration | read-write | current | Write configuration to module:This OID writes the complete configuration to the module |
| 1.3.6.1.4.1.20044.107.10 | Nodepm100gemuxsfptraps | |||
| 1.3.6.1.4.1.20044.107.10.2 | Scalarpm100gemuxsfptrapPortNumber | read-only | current | Last port which generates a trap |
| 1.3.6.1.4.1.20044.107.10.3 | Scalarpm100gemuxsfptrapLineNumber | read-only | current | Last Line which generates a trap |
| 1.3.6.1.4.1.20044.107.10.4 | Scalarpm100gemuxsfptrapBoardNumber | read-only | current | Last module which generates a trap |
| 1.3.6.1.4.1.20044.107.10.30 | Notificationpm100gemuxsfpLineTrapNotUrgentGoesOn | current | Not urgent Line default is activated | |
| 1.3.6.1.4.1.20044.107.10.31 | Notificationpm100gemuxsfpLineTrapNotUrgentGoesOff | current | Not urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.107.10.32 | Notificationpm100gemuxsfpLineTrapUrgentGoesOn | current | Urgent Line default is activated | |
| 1.3.6.1.4.1.20044.107.10.33 | Notificationpm100gemuxsfpLineTrapUrgentGoesOff | current | Urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.107.10.34 | Notificationpm100gemuxsfpLineTrapCritGoesOn | current | Critical Line default is activated | |
| 1.3.6.1.4.1.20044.107.10.35 | Notificationpm100gemuxsfpLineTrapCritGoesOff | current | Critical Line default disappeared | |
| 1.3.6.1.4.1.20044.107.10.40 | Notificationpm100gemuxsfpClientTrapNotUrgentGoesOn | current | Not urgent client default is activated | |
| 1.3.6.1.4.1.20044.107.10.41 | Notificationpm100gemuxsfpClientTrapNotUrgentGoesOff | current | Not urgent client default disappeared | |
| 1.3.6.1.4.1.20044.107.10.42 | Notificationpm100gemuxsfpClientTrapUrgentGoesOn | current | Urgent client default is activated | |
| 1.3.6.1.4.1.20044.107.10.43 | Notificationpm100gemuxsfpClientTrapUrgentGoesOff | current | Urgent client default disappeared | |
| 1.3.6.1.4.1.20044.107.10.44 | Notificationpm100gemuxsfpClientTrapCritGoesOn | current | Critical client default is activated | |
| 1.3.6.1.4.1.20044.107.10.45 | Notificationpm100gemuxsfpClientTrapCritGoesOff | current | Critical client default disappeared | |
| 1.3.6.1.4.1.20044.107.10.50 | Notificationpm100gemuxsfpPowerTrapUrgentGoesOn | current | Urgent power supply default is activated | |
| 1.3.6.1.4.1.20044.107.10.51 | Notificationpm100gemuxsfpPowerTrapUrgentGoesOff | current | Urgent power supply default disappeared | |
| 1.3.6.1.4.1.20044.107.11 | Nodepm100gemuxsfpMonitoring | |||
| 1.3.6.1.4.1.20044.107.11.1 | Nodepm100gemuxsfpMonOther | |||
| 1.3.6.1.4.1.20044.107.11.1.3 | Nodepm100gemuxsfpMonRmon | |||
| 1.3.6.1.4.1.20044.107.11.2 | Nodepm100gemuxsfpMonClient | |||
| 1.3.6.1.4.1.20044.107.11.2.4 | Nodepm100gemuxsfpMonClientRmonCounter | |||
| 1.3.6.1.4.1.20044.107.11.2.4.16 | Tablepm100gemuxsfpMonupRmonBytesCounterClientInputTable | not-accessible | current | List of pm100gemuxsfpMonupRmonBytesCounterClientInput Article |
| 1.3.6.1.4.1.20044.107.11.2.4.16.1 | Rowpm100gemuxsfpMonupRmonBytesCounterClientInputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMonupRmonBytesCounterClientInput table |
| 1.3.6.1.4.1.20044.107.11.2.4.16.1.1 | Columnpm100gemuxsfpMonupRmonBytesCounterClientInputIndex | read-only | current | Index definition for the pm100gemuxsfpMonupRmonBytesCounterClientInput table |
| 1.3.6.1.4.1.20044.107.11.2.4.16.1.2 | Columnpm100gemuxsfpMonupRmonBytesCounterClientInputValuePortn | read-only | current | Client Input Bytes :This counter is increased each time a data byte is received on the client port <Help> This counter gives the number of bytes received on th… |
| 1.3.6.1.4.1.20044.107.11.2.4.16.1.3 | Columnpm100gemuxsfpMonupRmonBytesCounterClientInputErrorPortn | read-only | current | Bytes Counter Error :This OID when set indicates the Bytes counter value is invalid on client port |
| 1.3.6.1.4.1.20044.107.11.2.4.16.1.4 | Columnpm100gemuxsfpMonupRmonBytesCounterClientInputOverloadPortn | read-only | current | Bytes Counter Overload :This OID when set indicates a Bytes counter overload on client port |
| 1.3.6.1.4.1.20044.107.11.2.4.48 | Tablepm100gemuxsfpMonupRmonCrcErrorsCounterClientInputTable | not-accessible | current | List of pm100gemuxsfpMonupRmonCrcErrorsCounterClientInput Article |
| 1.3.6.1.4.1.20044.107.11.2.4.48.1 | Rowpm100gemuxsfpMonupRmonCrcErrorsCounterClientInputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMonupRmonCrcErrorsCounterClientInput table |
| 1.3.6.1.4.1.20044.107.11.2.4.48.1.1 | Columnpm100gemuxsfpMonupRmonCrcErrorsCounterClientInputIndex | read-only | current | Index definition for the pm100gemuxsfpMonupRmonCrcErrorsCounterClientInput table |
| 1.3.6.1.4.1.20044.107.11.2.4.48.1.2 | Columnpm100gemuxsfpMonupRmonCrcErrorsCounterClientInputValuePortn | read-only | current | Client Input CRC Errors :This counter is increased each time a CRC error is detected on the client port<Help> This counter gives the number of CRC Errors recei… |
| 1.3.6.1.4.1.20044.107.11.2.4.48.1.3 | Columnpm100gemuxsfpMonupRmonCrcErrorsCounterClientInputErrorPortn | read-only | current | CRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on client port |
| 1.3.6.1.4.1.20044.107.11.2.4.48.1.4 | Columnpm100gemuxsfpMonupRmonCrcErrorsCounterClientInputOverloadPortn | read-only | current | CRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on client port |
| 1.3.6.1.4.1.20044.107.11.2.4.80 | Tablepm100gemuxsfpMonupRmonPacketsCounterClientInputTable | not-accessible | current | List of pm100gemuxsfpMonupRmonPacketsCounterClientInput Article |
| 1.3.6.1.4.1.20044.107.11.2.4.80.1 | Rowpm100gemuxsfpMonupRmonPacketsCounterClientInputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMonupRmonPacketsCounterClientInput table |
| 1.3.6.1.4.1.20044.107.11.2.4.80.1.1 | Columnpm100gemuxsfpMonupRmonPacketsCounterClientInputIndex | read-only | current | Index definition for the pm100gemuxsfpMonupRmonPacketsCounterClientInput table |
| 1.3.6.1.4.1.20044.107.11.2.4.80.1.2 | Columnpm100gemuxsfpMonupRmonPacketsCounterClientInputValuePortn | read-only | current | Client Input Packets :This counter is increased each time a packet is received on the client port <Help> This counter gives the number of packets received on t… |
| 1.3.6.1.4.1.20044.107.11.2.4.80.1.3 | Columnpm100gemuxsfpMonupRmonPacketsCounterClientInputErrorPortn | read-only | current | Packets Counter Error :This OID when set indicates the Packets counter value is invalid on client port |
| 1.3.6.1.4.1.20044.107.11.2.4.80.1.4 | Columnpm100gemuxsfpMonupRmonPacketsCounterClientInputOverloadPortn | read-only | current | Packets Counter Overload :This OID when set indicates a Packets counter overload on client port |
| 1.3.6.1.4.1.20044.107.11.2.4.112 | Tablepm100gemuxsfpMonupRmonBroadcastCounterClientInputTable | not-accessible | current | List of pm100gemuxsfpMonupRmonBroadcastCounterClientInput Article |
| 1.3.6.1.4.1.20044.107.11.2.4.112.1 | Rowpm100gemuxsfpMonupRmonBroadcastCounterClientInputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMonupRmonBroadcastCounterClientInput table |
| 1.3.6.1.4.1.20044.107.11.2.4.112.1.1 | Columnpm100gemuxsfpMonupRmonBroadcastCounterClientInputIndex | read-only | current | Index definition for the pm100gemuxsfpMonupRmonBroadcastCounterClientInput table |
| 1.3.6.1.4.1.20044.107.11.2.4.112.1.2 | Columnpm100gemuxsfpMonupRmonBroadcastCounterClientInputValuePortn | read-only | current | Client Input Broadcast Packets :This counter is increased each time a broadcast packet is received on the client port <Help> This counter gives the number of B… |
| 1.3.6.1.4.1.20044.107.11.2.4.112.1.3 | Columnpm100gemuxsfpMonupRmonBroadcastCounterClientInputErrorPortn | read-only | current | Broadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.107.11.2.4.112.1.4 | Columnpm100gemuxsfpMonupRmonBroadcastCounterClientInputOverloadPortn | read-only | current | Broadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port |
| 1.3.6.1.4.1.20044.107.11.2.4.144 | Tablepm100gemuxsfpMonupRmonMulticastCounterClientInputTable | not-accessible | current | List of pm100gemuxsfpMonupRmonMulticastCounterClientInput Article |
| 1.3.6.1.4.1.20044.107.11.2.4.144.1 | Rowpm100gemuxsfpMonupRmonMulticastCounterClientInputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMonupRmonMulticastCounterClientInput table |
| 1.3.6.1.4.1.20044.107.11.2.4.144.1.1 | Columnpm100gemuxsfpMonupRmonMulticastCounterClientInputIndex | read-only | current | Index definition for the pm100gemuxsfpMonupRmonMulticastCounterClientInput table |
| 1.3.6.1.4.1.20044.107.11.2.4.144.1.2 | Columnpm100gemuxsfpMonupRmonMulticastCounterClientInputValuePortn | read-only | current | Client Input Multicast Packets :This counter is increased each time a Multicast packet is received on the client port <Help> This counter gives the number of M… |
| 1.3.6.1.4.1.20044.107.11.2.4.144.1.3 | Columnpm100gemuxsfpMonupRmonMulticastCounterClientInputErrorPortn | read-only | current | Multicast Counter Error :This OID when set indicates the Multicast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.107.11.2.4.144.1.4 | Columnpm100gemuxsfpMonupRmonMulticastCounterClientInputOverloadPortn | read-only | current | Multicast Counter Overload :This OID when set indicates a Multicast counter overload on client port |
| 1.3.6.1.4.1.20044.107.11.2.4.176 | Tablepm100gemuxsfpMonupRmonPauseFrameCounterClientInputTable | not-accessible | current | List of pm100gemuxsfpMonupRmonPauseFrameCounterClientInput Article |
| 1.3.6.1.4.1.20044.107.11.2.4.176.1 | Rowpm100gemuxsfpMonupRmonPauseFrameCounterClientInputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMonupRmonPauseFrameCounterClientInput table |
| 1.3.6.1.4.1.20044.107.11.2.4.176.1.1 | Columnpm100gemuxsfpMonupRmonPauseFrameCounterClientInputIndex | read-only | current | Index definition for the pm100gemuxsfpMonupRmonPauseFrameCounterClientInput table |
| 1.3.6.1.4.1.20044.107.11.2.4.176.1.2 | Columnpm100gemuxsfpMonupRmonPauseFrameCounterClientInputValuePortn | read-only | current | Client Input Pause Frames :This counter is increased each time a Pause frame is received on the client port <Help> This counter gives the number of Pause frame… |
| 1.3.6.1.4.1.20044.107.11.2.4.176.1.3 | Columnpm100gemuxsfpMonupRmonPauseFrameCounterClientInputErrorPortn | read-only | current | Pause Counter Error :This OID when set indicates the Pause counter value is invalid on client port |
| 1.3.6.1.4.1.20044.107.11.2.4.176.1.4 | Columnpm100gemuxsfpMonupRmonPauseFrameCounterClientInputOverloadPortn | read-only | current | Pause Counter Overload :This OID when set indicates a Pause counter overload on client port |
| 1.3.6.1.4.1.20044.107.11.2.4.304 | Tablepm100gemuxsfpMonupRmonUnicastCounterClientInputTable | not-accessible | current | List of pm100gemuxsfpMonupRmonUnicastCounterClientInput Article |
| 1.3.6.1.4.1.20044.107.11.2.4.304.1 | Rowpm100gemuxsfpMonupRmonUnicastCounterClientInputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMonupRmonUnicastCounterClientInput table |
| 1.3.6.1.4.1.20044.107.11.2.4.304.1.1 | Columnpm100gemuxsfpMonupRmonUnicastCounterClientInputIndex | read-only | current | Index definition for the pm100gemuxsfpMonupRmonUnicastCounterClientInput table |
| 1.3.6.1.4.1.20044.107.11.2.4.304.1.2 | Columnpm100gemuxsfpMonupRmonUnicastCounterClientInputValuePortn | read-only | current | Client Input Unicast Packets :This counter is increased each time a Unicast packet is received on the client port <Help> This counter gives the number of Unica… |
| 1.3.6.1.4.1.20044.107.11.2.4.304.1.3 | Columnpm100gemuxsfpMonupRmonUnicastCounterClientInputErrorPortn | read-only | current | Unicast Counter Error :This OID when set indicates the Unicast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.107.11.2.4.304.1.4 | Columnpm100gemuxsfpMonupRmonUnicastCounterClientInputOverloadPortn | read-only | current | Unicast Counter Overload :This OID when set indicates a Unicast counter overload on client port |
| 1.3.6.1.4.1.20044.107.11.2.4.336 | Tablepm100gemuxsfpMonupRmonNonunicastCounterClientInputTable | not-accessible | current | List of pm100gemuxsfpMonupRmonNonunicastCounterClientInput Article |
| 1.3.6.1.4.1.20044.107.11.2.4.336.1 | Rowpm100gemuxsfpMonupRmonNonunicastCounterClientInputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMonupRmonNonunicastCounterClientInput table |
| 1.3.6.1.4.1.20044.107.11.2.4.336.1.1 | Columnpm100gemuxsfpMonupRmonNonunicastCounterClientInputIndex | read-only | current | Index definition for the pm100gemuxsfpMonupRmonNonunicastCounterClientInput table |
| 1.3.6.1.4.1.20044.107.11.2.4.336.1.2 | Columnpm100gemuxsfpMonupRmonNonunicastCounterClientInputValuePortn | read-only | current | Client Input Non Unicast Packets :This counter is increased each time a Non-Unicast packet is received on the client port <Help> This counter gives the number … |
| 1.3.6.1.4.1.20044.107.11.2.4.336.1.3 | Columnpm100gemuxsfpMonupRmonNonunicastCounterClientInputErrorPortn | read-only | current | Non Unicast Counter Error :This OID when set indicates the Non-Unicast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.107.11.2.4.336.1.4 | Columnpm100gemuxsfpMonupRmonNonunicastCounterClientInputOverloadPortn | read-only | current | Non Unicast Counter Overload :This OID when set indicates a Non-Unicast counter overload on client port |
| 1.3.6.1.4.1.20044.107.11.2.4.400 | Tablepm100gemuxsfpMondownRmonBytesCounterClientOutputTable | not-accessible | current | List of pm100gemuxsfpMondownRmonBytesCounterClientOutput Article |
| 1.3.6.1.4.1.20044.107.11.2.4.400.1 | Rowpm100gemuxsfpMondownRmonBytesCounterClientOutputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMondownRmonBytesCounterClientOutput table |
| 1.3.6.1.4.1.20044.107.11.2.4.400.1.1 | Columnpm100gemuxsfpMondownRmonBytesCounterClientOutputIndex | read-only | current | Index definition for the pm100gemuxsfpMondownRmonBytesCounterClientOutput table |
| 1.3.6.1.4.1.20044.107.11.2.4.400.1.2 | Columnpm100gemuxsfpMondownRmonBytesCounterClientOutputValuePortn | read-only | current | Client Output Bytes :This counter is increased each time a data byte is transmitted on the client port <Help> This counter gives the number of bytes transmitte… |
| 1.3.6.1.4.1.20044.107.11.2.4.400.1.3 | Columnpm100gemuxsfpMondownRmonBytesCounterClientOutputErrorPortn | read-only | current | Bytes Counter Error :This OID when set indicates the Bytes counter value is invalid on client port |
| 1.3.6.1.4.1.20044.107.11.2.4.400.1.4 | Columnpm100gemuxsfpMondownRmonBytesCounterClientOutputOverloadPortn | read-only | current | Bytes Counter Overload :This OID when set indicates a Bytes counter overload on client port |
| 1.3.6.1.4.1.20044.107.11.2.4.432 | Tablepm100gemuxsfpMondownRmonCrcErrorsCounterClientOutputTable | not-accessible | current | List of pm100gemuxsfpMondownRmonCrcErrorsCounterClientOutput Article |
| 1.3.6.1.4.1.20044.107.11.2.4.432.1 | Rowpm100gemuxsfpMondownRmonCrcErrorsCounterClientOutputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMondownRmonCrcErrorsCounterClientOutput table |
| 1.3.6.1.4.1.20044.107.11.2.4.432.1.1 | Columnpm100gemuxsfpMondownRmonCrcErrorsCounterClientOutputIndex | read-only | current | Index definition for the pm100gemuxsfpMondownRmonCrcErrorsCounterClientOutput table |
| 1.3.6.1.4.1.20044.107.11.2.4.432.1.2 | Columnpm100gemuxsfpMondownRmonCrcErrorsCounterClientOutputValuePortn | read-only | current | Client Output CRC Errors :This counter is increased each time a CRC error is detected on the transmit client port <Help> This counter gives the number of CRC E… |
| 1.3.6.1.4.1.20044.107.11.2.4.432.1.3 | Columnpm100gemuxsfpMondownRmonCrcErrorsCounterClientOutputErrorPortn | read-only | current | CRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on client port |
| 1.3.6.1.4.1.20044.107.11.2.4.432.1.4 | Columnpm100gemuxsfpMondownRmonCrcErrorsCounterClientOutputOverloadPortn | read-only | current | CRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on client port |
| 1.3.6.1.4.1.20044.107.11.2.4.464 | Tablepm100gemuxsfpMondownRmonPacketsCounterClientOutputTable | not-accessible | current | List of pm100gemuxsfpMondownRmonPacketsCounterClientOutput Article |
| 1.3.6.1.4.1.20044.107.11.2.4.464.1 | Rowpm100gemuxsfpMondownRmonPacketsCounterClientOutputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMondownRmonPacketsCounterClientOutput table |
| 1.3.6.1.4.1.20044.107.11.2.4.464.1.1 | Columnpm100gemuxsfpMondownRmonPacketsCounterClientOutputIndex | read-only | current | Index definition for the pm100gemuxsfpMondownRmonPacketsCounterClientOutput table |
| 1.3.6.1.4.1.20044.107.11.2.4.464.1.2 | Columnpm100gemuxsfpMondownRmonPacketsCounterClientOutputValuePortn | read-only | current | Client Output Packets :This counter is increased each time a packet is transmitted on the client port <Help> This counter gives the number of packets transmitt… |
| 1.3.6.1.4.1.20044.107.11.2.4.464.1.3 | Columnpm100gemuxsfpMondownRmonPacketsCounterClientOutputErrorPortn | read-only | current | Packets Counter Error :This OID when set indicates the Packets counter value is invalid on client port |
| 1.3.6.1.4.1.20044.107.11.2.4.464.1.4 | Columnpm100gemuxsfpMondownRmonPacketsCounterClientOutputOverloadPortn | read-only | current | Packets Counter Overload :This OID when set indicates a Packets counter overload on client port |
| 1.3.6.1.4.1.20044.107.11.2.4.496 | Tablepm100gemuxsfpMondownRmonBroadcastCounterClientOutputTable | not-accessible | current | List of pm100gemuxsfpMondownRmonBroadcastCounterClientOutput Article |
| 1.3.6.1.4.1.20044.107.11.2.4.496.1 | Rowpm100gemuxsfpMondownRmonBroadcastCounterClientOutputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMondownRmonBroadcastCounterClientOutput table |
| 1.3.6.1.4.1.20044.107.11.2.4.496.1.1 | Columnpm100gemuxsfpMondownRmonBroadcastCounterClientOutputIndex | read-only | current | Index definition for the pm100gemuxsfpMondownRmonBroadcastCounterClientOutput table |
| 1.3.6.1.4.1.20044.107.11.2.4.496.1.2 | Columnpm100gemuxsfpMondownRmonBroadcastCounterClientOutputValuePortn | read-only | current | Client Output Broadcast Packets :This counter is increased each time a broadcast packet is transmitted on the client port <Help> This counter gives the number … |
| 1.3.6.1.4.1.20044.107.11.2.4.496.1.3 | Columnpm100gemuxsfpMondownRmonBroadcastCounterClientOutputErrorPortn | read-only | current | Broadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.107.11.2.4.496.1.4 | Columnpm100gemuxsfpMondownRmonBroadcastCounterClientOutputOverloadPortn | read-only | current | Broadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port |
| 1.3.6.1.4.1.20044.107.11.2.4.528 | Tablepm100gemuxsfpMondownRmonMulticastCounterClientOutputTable | not-accessible | current | List of pm100gemuxsfpMondownRmonMulticastCounterClientOutput Article |
| 1.3.6.1.4.1.20044.107.11.2.4.528.1 | Rowpm100gemuxsfpMondownRmonMulticastCounterClientOutputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMondownRmonMulticastCounterClientOutput table |
| 1.3.6.1.4.1.20044.107.11.2.4.528.1.1 | Columnpm100gemuxsfpMondownRmonMulticastCounterClientOutputIndex | read-only | current | Index definition for the pm100gemuxsfpMondownRmonMulticastCounterClientOutput table |
| 1.3.6.1.4.1.20044.107.11.2.4.528.1.2 | Columnpm100gemuxsfpMondownRmonMulticastCounterClientOutputValuePortn | read-only | current | Client Output Multicast Packets :This counter is increased each time a Multicast packet is transmitted on the client port <Help> This counter gives the number … |
| 1.3.6.1.4.1.20044.107.11.2.4.528.1.3 | Columnpm100gemuxsfpMondownRmonMulticastCounterClientOutputErrorPortn | read-only | current | Multicast Counter Error :This OID when set indicates the Multicast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.107.11.2.4.528.1.4 | Columnpm100gemuxsfpMondownRmonMulticastCounterClientOutputOverloadPortn | read-only | current | Multicast Counter Overload :This OID when set indicates a Multicast counter overload on client port |
| 1.3.6.1.4.1.20044.107.11.2.4.560 | Tablepm100gemuxsfpMondownRmonPauseFrameCounterClientOutputTable | not-accessible | current | List of pm100gemuxsfpMondownRmonPauseFrameCounterClientOutput Article |
| 1.3.6.1.4.1.20044.107.11.2.4.560.1 | Rowpm100gemuxsfpMondownRmonPauseFrameCounterClientOutputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMondownRmonPauseFrameCounterClientOutput table |
| 1.3.6.1.4.1.20044.107.11.2.4.560.1.1 | Columnpm100gemuxsfpMondownRmonPauseFrameCounterClientOutputIndex | read-only | current | Index definition for the pm100gemuxsfpMondownRmonPauseFrameCounterClientOutput table |
| 1.3.6.1.4.1.20044.107.11.2.4.560.1.2 | Columnpm100gemuxsfpMondownRmonPauseFrameCounterClientOutputValuePortn | read-only | current | Client Output Pause Frames :This counter is increased each time a Pause frame is transmitted on the client port <Help> This counter gives the number of Pause f… |
| 1.3.6.1.4.1.20044.107.11.2.4.560.1.3 | Columnpm100gemuxsfpMondownRmonPauseFrameCounterClientOutputErrorPortn | read-only | current | Pause Counter Error :This OID when set indicates the Pause counter value is invalid on client port |
| 1.3.6.1.4.1.20044.107.11.2.4.560.1.4 | Columnpm100gemuxsfpMondownRmonPauseFrameCounterClientOutputOverloadPortn | read-only | current | Pause Counter Overload :This OID when set indicates a Pause counter overload on client port |
| 1.3.6.1.4.1.20044.107.11.2.4.688 | Tablepm100gemuxsfpMondownRmonUnicastCounterClientOutputTable | not-accessible | current | List of pm100gemuxsfpMondownRmonUnicastCounterClientOutput Article |
| 1.3.6.1.4.1.20044.107.11.2.4.688.1 | Rowpm100gemuxsfpMondownRmonUnicastCounterClientOutputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMondownRmonUnicastCounterClientOutput table |
| 1.3.6.1.4.1.20044.107.11.2.4.688.1.1 | Columnpm100gemuxsfpMondownRmonUnicastCounterClientOutputIndex | read-only | current | Index definition for the pm100gemuxsfpMondownRmonUnicastCounterClientOutput table |
| 1.3.6.1.4.1.20044.107.11.2.4.688.1.2 | Columnpm100gemuxsfpMondownRmonUnicastCounterClientOutputValuePortn | read-only | current | Client Output Unicast Packets :This counter is increased each time a Unicast packet is transmitted on the client port <Help> This counter gives the number of U… |
| 1.3.6.1.4.1.20044.107.11.2.4.688.1.3 | Columnpm100gemuxsfpMondownRmonUnicastCounterClientOutputErrorPortn | read-only | current | Unicast Counter Error :This OID when set indicates the Unicast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.107.11.2.4.688.1.4 | Columnpm100gemuxsfpMondownRmonUnicastCounterClientOutputOverloadPortn | read-only | current | Unicast Counter Overload :This OID when set indicates a Unicast counter overload on client port |
| 1.3.6.1.4.1.20044.107.11.2.4.720 | Tablepm100gemuxsfpMondownRmonNonunicastCounterClientOutputTable | not-accessible | current | List of pm100gemuxsfpMondownRmonNonunicastCounterClientOutput Article |
| 1.3.6.1.4.1.20044.107.11.2.4.720.1 | Rowpm100gemuxsfpMondownRmonNonunicastCounterClientOutputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMondownRmonNonunicastCounterClientOutput table |
| 1.3.6.1.4.1.20044.107.11.2.4.720.1.1 | Columnpm100gemuxsfpMondownRmonNonunicastCounterClientOutputIndex | read-only | current | Index definition for the pm100gemuxsfpMondownRmonNonunicastCounterClientOutput table |
| 1.3.6.1.4.1.20044.107.11.2.4.720.1.2 | Columnpm100gemuxsfpMondownRmonNonunicastCounterClientOutputValuePortn | read-only | current | Client Output Non Unicast Packets :This counter is increased each time a Non-Unicast packet is transmitted on the client port <Help> This counter gives the num… |
| 1.3.6.1.4.1.20044.107.11.2.4.720.1.3 | Columnpm100gemuxsfpMondownRmonNonunicastCounterClientOutputErrorPortn | read-only | current | Non Unicast Counter Error :This OID when set indicates the Non-Unicast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.107.11.2.4.720.1.4 | Columnpm100gemuxsfpMondownRmonNonunicastCounterClientOutputOverloadPortn | read-only | current | Non Unicast Counter Overload :This OID when set indicates a Non-Unicast counter overload on client port |
| 1.3.6.1.4.1.20044.107.11.3 | Nodepm100gemuxsfpMonLigne | |||
| 1.3.6.1.4.1.20044.107.11.3.4 | Nodepm100gemuxsfpMonLineRmonCounter | |||
| 1.3.6.1.4.1.20044.107.11.3.4.784 | Tablepm100gemuxsfpMonupRmonBytesCounterLineInputTable | not-accessible | current | List of pm100gemuxsfpMonupRmonBytesCounterLineInput Article |
| 1.3.6.1.4.1.20044.107.11.3.4.784.1 | Rowpm100gemuxsfpMonupRmonBytesCounterLineInputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMonupRmonBytesCounterLineInput table |
| 1.3.6.1.4.1.20044.107.11.3.4.784.1.1 | Columnpm100gemuxsfpMonupRmonBytesCounterLineInputIndex | read-only | current | Index definition for the pm100gemuxsfpMonupRmonBytesCounterLineInput table |
| 1.3.6.1.4.1.20044.107.11.3.4.784.1.2 | Columnpm100gemuxsfpMonupRmonBytesCounterLineInputValuePortn | read-only | current | Line Input Bytes :This counter is increased each time a data byte is received on the Line port <Help> This counter gives the number of bytes received on the Li… |
| 1.3.6.1.4.1.20044.107.11.3.4.784.1.3 | Columnpm100gemuxsfpMonupRmonBytesCounterLineInputErrorPortn | read-only | current | Bytes Counter Error :This OID when set indicates the Bytes counter value is invalid on Line port |
| 1.3.6.1.4.1.20044.107.11.3.4.784.1.4 | Columnpm100gemuxsfpMonupRmonBytesCounterLineInputOverloadPortn | read-only | current | Bytes Counter Overload :This OID when set indicates a Bytes counter overload on Line port |
| 1.3.6.1.4.1.20044.107.11.3.4.786 | Tablepm100gemuxsfpMonupRmonCrcErrorsCounterLineInputTable | not-accessible | current | List of pm100gemuxsfpMonupRmonCrcErrorsCounterLineInput Article |
| 1.3.6.1.4.1.20044.107.11.3.4.786.1 | Rowpm100gemuxsfpMonupRmonCrcErrorsCounterLineInputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMonupRmonCrcErrorsCounterLineInput table |
| 1.3.6.1.4.1.20044.107.11.3.4.786.1.1 | Columnpm100gemuxsfpMonupRmonCrcErrorsCounterLineInputIndex | read-only | current | Index definition for the pm100gemuxsfpMonupRmonCrcErrorsCounterLineInput table |
| 1.3.6.1.4.1.20044.107.11.3.4.786.1.2 | Columnpm100gemuxsfpMonupRmonCrcErrorsCounterLineInputValuePortn | read-only | current | Line Input CRC Errors :This counter is increased each time a CRC error is detected on the Line port<Help> This counter gives the number of CRC Errors received … |
| 1.3.6.1.4.1.20044.107.11.3.4.786.1.3 | Columnpm100gemuxsfpMonupRmonCrcErrorsCounterLineInputErrorPortn | read-only | current | CRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on Line port |
| 1.3.6.1.4.1.20044.107.11.3.4.786.1.4 | Columnpm100gemuxsfpMonupRmonCrcErrorsCounterLineInputOverloadPortn | read-only | current | CRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on Line port |
| 1.3.6.1.4.1.20044.107.11.3.4.788 | Tablepm100gemuxsfpMonupRmonPacketsCounterLineInputTable | not-accessible | current | List of pm100gemuxsfpMonupRmonPacketsCounterLineInput Article |
| 1.3.6.1.4.1.20044.107.11.3.4.788.1 | Rowpm100gemuxsfpMonupRmonPacketsCounterLineInputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMonupRmonPacketsCounterLineInput table |
| 1.3.6.1.4.1.20044.107.11.3.4.788.1.1 | Columnpm100gemuxsfpMonupRmonPacketsCounterLineInputIndex | read-only | current | Index definition for the pm100gemuxsfpMonupRmonPacketsCounterLineInput table |
| 1.3.6.1.4.1.20044.107.11.3.4.788.1.2 | Columnpm100gemuxsfpMonupRmonPacketsCounterLineInputValuePortn | read-only | current | Line Input Packets :This counter is increased each time a packet is received on the Line port <Help> This counter gives the number of packets received on the L… |
| 1.3.6.1.4.1.20044.107.11.3.4.788.1.3 | Columnpm100gemuxsfpMonupRmonPacketsCounterLineInputErrorPortn | read-only | current | Packets Counter Error :This OID when set indicates the Packets counter value is invalid on Line port |
| 1.3.6.1.4.1.20044.107.11.3.4.788.1.4 | Columnpm100gemuxsfpMonupRmonPacketsCounterLineInputOverloadPortn | read-only | current | Packets Counter Overload :This OID when set indicates a Packets counter overload on Line port |
| 1.3.6.1.4.1.20044.107.11.3.4.790 | Tablepm100gemuxsfpMonupRmonBroadcastCounterLineInputTable | not-accessible | current | List of pm100gemuxsfpMonupRmonBroadcastCounterLineInput Article |
| 1.3.6.1.4.1.20044.107.11.3.4.790.1 | Rowpm100gemuxsfpMonupRmonBroadcastCounterLineInputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMonupRmonBroadcastCounterLineInput table |
| 1.3.6.1.4.1.20044.107.11.3.4.790.1.1 | Columnpm100gemuxsfpMonupRmonBroadcastCounterLineInputIndex | read-only | current | Index definition for the pm100gemuxsfpMonupRmonBroadcastCounterLineInput table |
| 1.3.6.1.4.1.20044.107.11.3.4.790.1.2 | Columnpm100gemuxsfpMonupRmonBroadcastCounterLineInputValuePortn | read-only | current | Line Input Broadcast Packets :This counter is increased each time a broadcast packet is received on the Line port <Help> This counter gives the number of Broad… |
| 1.3.6.1.4.1.20044.107.11.3.4.790.1.3 | Columnpm100gemuxsfpMonupRmonBroadcastCounterLineInputErrorPortn | read-only | current | Broadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on Line port |
| 1.3.6.1.4.1.20044.107.11.3.4.790.1.4 | Columnpm100gemuxsfpMonupRmonBroadcastCounterLineInputOverloadPortn | read-only | current | Broadcast Counter Overload :This OID when set indicates a Broadcast counter overload on Line port |
| 1.3.6.1.4.1.20044.107.11.3.4.792 | Tablepm100gemuxsfpMonupRmonMulticastCounterLineInputTable | not-accessible | current | List of pm100gemuxsfpMonupRmonMulticastCounterLineInput Article |
| 1.3.6.1.4.1.20044.107.11.3.4.792.1 | Rowpm100gemuxsfpMonupRmonMulticastCounterLineInputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMonupRmonMulticastCounterLineInput table |
| 1.3.6.1.4.1.20044.107.11.3.4.792.1.1 | Columnpm100gemuxsfpMonupRmonMulticastCounterLineInputIndex | read-only | current | Index definition for the pm100gemuxsfpMonupRmonMulticastCounterLineInput table |
| 1.3.6.1.4.1.20044.107.11.3.4.792.1.2 | Columnpm100gemuxsfpMonupRmonMulticastCounterLineInputValuePortn | read-only | current | Line Input Multicast Packets :This counter is increased each time a Multicast packet is received on the Line port <Help> This counter gives the number of Multi… |
| 1.3.6.1.4.1.20044.107.11.3.4.792.1.3 | Columnpm100gemuxsfpMonupRmonMulticastCounterLineInputErrorPortn | read-only | current | Multicast Counter Error :This OID when set indicates the Multicast counter value is invalid on Line port |
| 1.3.6.1.4.1.20044.107.11.3.4.792.1.4 | Columnpm100gemuxsfpMonupRmonMulticastCounterLineInputOverloadPortn | read-only | current | Multicast Counter Overload :This OID when set indicates a Multicast counter overload on Line port |
| 1.3.6.1.4.1.20044.107.11.3.4.794 | Tablepm100gemuxsfpMonupRmonPauseFrameCounterLineInputTable | not-accessible | current | List of pm100gemuxsfpMonupRmonPauseFrameCounterLineInput Article |
| 1.3.6.1.4.1.20044.107.11.3.4.794.1 | Rowpm100gemuxsfpMonupRmonPauseFrameCounterLineInputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMonupRmonPauseFrameCounterLineInput table |
| 1.3.6.1.4.1.20044.107.11.3.4.794.1.1 | Columnpm100gemuxsfpMonupRmonPauseFrameCounterLineInputIndex | read-only | current | Index definition for the pm100gemuxsfpMonupRmonPauseFrameCounterLineInput table |
| 1.3.6.1.4.1.20044.107.11.3.4.794.1.2 | Columnpm100gemuxsfpMonupRmonPauseFrameCounterLineInputValuePortn | read-only | current | Line Input Pause Frames :This counter is increased each time a Pause frame is received on the Line port <Help> This counter gives the number of Pause frames re… |
| 1.3.6.1.4.1.20044.107.11.3.4.794.1.3 | Columnpm100gemuxsfpMonupRmonPauseFrameCounterLineInputErrorPortn | read-only | current | Pause Counter Error :This OID when set indicates the Pause counter value is invalid on Line port |
| 1.3.6.1.4.1.20044.107.11.3.4.794.1.4 | Columnpm100gemuxsfpMonupRmonPauseFrameCounterLineInputOverloadPortn | read-only | current | Pause Counter Overload :This OID when set indicates a Pause counter overload on Line port |
| 1.3.6.1.4.1.20044.107.11.3.4.796 | Tablepm100gemuxsfpMonupRmonUnicastCounterLineInputTable | not-accessible | current | List of pm100gemuxsfpMonupRmonUnicastCounterLineInput Article |
| 1.3.6.1.4.1.20044.107.11.3.4.796.1 | Rowpm100gemuxsfpMonupRmonUnicastCounterLineInputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMonupRmonUnicastCounterLineInput table |
| 1.3.6.1.4.1.20044.107.11.3.4.796.1.1 | Columnpm100gemuxsfpMonupRmonUnicastCounterLineInputIndex | read-only | current | Index definition for the pm100gemuxsfpMonupRmonUnicastCounterLineInput table |
| 1.3.6.1.4.1.20044.107.11.3.4.796.1.2 | Columnpm100gemuxsfpMonupRmonUnicastCounterLineInputValuePortn | read-only | current | Line Input Unicast Packets :This counter is increased each time a Unicast packet is received on the Line port <Help> This counter gives the number of Unicast p… |
| 1.3.6.1.4.1.20044.107.11.3.4.796.1.3 | Columnpm100gemuxsfpMonupRmonUnicastCounterLineInputErrorPortn | read-only | current | Unicast Counter Error :This OID when set indicates the Unicast counter value is invalid on Line port |
| 1.3.6.1.4.1.20044.107.11.3.4.796.1.4 | Columnpm100gemuxsfpMonupRmonUnicastCounterLineInputOverloadPortn | read-only | current | Unicast Counter Overload :This OID when set indicates a Unicast counter overload on Line port |
| 1.3.6.1.4.1.20044.107.11.3.4.798 | Tablepm100gemuxsfpMonupRmonNonunicastCounterLineInputTable | not-accessible | current | List of pm100gemuxsfpMonupRmonNonunicastCounterLineInput Article |
| 1.3.6.1.4.1.20044.107.11.3.4.798.1 | Rowpm100gemuxsfpMonupRmonNonunicastCounterLineInputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMonupRmonNonunicastCounterLineInput table |
| 1.3.6.1.4.1.20044.107.11.3.4.798.1.1 | Columnpm100gemuxsfpMonupRmonNonunicastCounterLineInputIndex | read-only | current | Index definition for the pm100gemuxsfpMonupRmonNonunicastCounterLineInput table |
| 1.3.6.1.4.1.20044.107.11.3.4.798.1.2 | Columnpm100gemuxsfpMonupRmonNonunicastCounterLineInputValuePortn | read-only | current | Line Input Non Unicast Packets :This counter is increased each time a Non-Unicast packet is received on the Line port <Help> This counter gives the number of N… |
| 1.3.6.1.4.1.20044.107.11.3.4.798.1.3 | Columnpm100gemuxsfpMonupRmonNonunicastCounterLineInputErrorPortn | read-only | current | Non Unicast Counter Error :This OID when set indicates the Non-Unicast counter value is invalid on Line port |
| 1.3.6.1.4.1.20044.107.11.3.4.798.1.4 | Columnpm100gemuxsfpMonupRmonNonunicastCounterLineInputOverloadPortn | read-only | current | Non Unicast Counter Overload :This OID when set indicates a Non-Unicast counter overload on Line port |
| 1.3.6.1.4.1.20044.107.11.3.4.800 | Tablepm100gemuxsfpMondownRmonBytesCounterLineOutputTable | not-accessible | current | List of pm100gemuxsfpMondownRmonBytesCounterLineOutput Article |
| 1.3.6.1.4.1.20044.107.11.3.4.800.1 | Rowpm100gemuxsfpMondownRmonBytesCounterLineOutputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMondownRmonBytesCounterLineOutput table |
| 1.3.6.1.4.1.20044.107.11.3.4.800.1.1 | Columnpm100gemuxsfpMondownRmonBytesCounterLineOutputIndex | read-only | current | Index definition for the pm100gemuxsfpMondownRmonBytesCounterLineOutput table |
| 1.3.6.1.4.1.20044.107.11.3.4.800.1.2 | Columnpm100gemuxsfpMondownRmonBytesCounterLineOutputValuePortn | read-only | current | Line Output Bytes :This counter is increased each time a data byte is transmitted on the Line port <Help> This counter gives the number of bytes transmitted on… |
| 1.3.6.1.4.1.20044.107.11.3.4.800.1.3 | Columnpm100gemuxsfpMondownRmonBytesCounterLineOutputErrorPortn | read-only | current | Bytes Counter Error :This OID when set indicates the Bytes counter value is invalid on Line port |
| 1.3.6.1.4.1.20044.107.11.3.4.800.1.4 | Columnpm100gemuxsfpMondownRmonBytesCounterLineOutputOverloadPortn | read-only | current | Bytes Counter Overload :This OID when set indicates a Bytes counter overload on Line port |
| 1.3.6.1.4.1.20044.107.11.3.4.802 | Tablepm100gemuxsfpMondownRmonCrcErrorsCounterLineOutputTable | not-accessible | current | List of pm100gemuxsfpMondownRmonCrcErrorsCounterLineOutput Article |
| 1.3.6.1.4.1.20044.107.11.3.4.802.1 | Rowpm100gemuxsfpMondownRmonCrcErrorsCounterLineOutputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMondownRmonCrcErrorsCounterLineOutput table |
| 1.3.6.1.4.1.20044.107.11.3.4.802.1.1 | Columnpm100gemuxsfpMondownRmonCrcErrorsCounterLineOutputIndex | read-only | current | Index definition for the pm100gemuxsfpMondownRmonCrcErrorsCounterLineOutput table |
| 1.3.6.1.4.1.20044.107.11.3.4.802.1.2 | Columnpm100gemuxsfpMondownRmonCrcErrorsCounterLineOutputValuePortn | read-only | current | Line Output CRC Errors :This counter is increased each time a CRC error is detected on the transmit Line port <Help> This counter gives the number of CRC Error… |
| 1.3.6.1.4.1.20044.107.11.3.4.802.1.3 | Columnpm100gemuxsfpMondownRmonCrcErrorsCounterLineOutputErrorPortn | read-only | current | CRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on Line port |
| 1.3.6.1.4.1.20044.107.11.3.4.802.1.4 | Columnpm100gemuxsfpMondownRmonCrcErrorsCounterLineOutputOverloadPortn | read-only | current | CRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on Line port |
| 1.3.6.1.4.1.20044.107.11.3.4.804 | Tablepm100gemuxsfpMondownRmonPacketsCounterLineOutputTable | not-accessible | current | List of pm100gemuxsfpMondownRmonPacketsCounterLineOutput Article |
| 1.3.6.1.4.1.20044.107.11.3.4.804.1 | Rowpm100gemuxsfpMondownRmonPacketsCounterLineOutputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMondownRmonPacketsCounterLineOutput table |
| 1.3.6.1.4.1.20044.107.11.3.4.804.1.1 | Columnpm100gemuxsfpMondownRmonPacketsCounterLineOutputIndex | read-only | current | Index definition for the pm100gemuxsfpMondownRmonPacketsCounterLineOutput table |
| 1.3.6.1.4.1.20044.107.11.3.4.804.1.2 | Columnpm100gemuxsfpMondownRmonPacketsCounterLineOutputValuePortn | read-only | current | Line Output Packets :This counter is increased each time a packet is transmitted on the Line port <Help> This counter gives the number of packets transmitted o… |
| 1.3.6.1.4.1.20044.107.11.3.4.804.1.3 | Columnpm100gemuxsfpMondownRmonPacketsCounterLineOutputErrorPortn | read-only | current | Packets Counter Error :This OID when set indicates the Packets counter value is invalid on Line port |
| 1.3.6.1.4.1.20044.107.11.3.4.804.1.4 | Columnpm100gemuxsfpMondownRmonPacketsCounterLineOutputOverloadPortn | read-only | current | Packets Counter Overload :This OID when set indicates a Packets counter overload on Line port |
| 1.3.6.1.4.1.20044.107.11.3.4.806 | Tablepm100gemuxsfpMondownRmonBroadcastCounterLineOutputTable | not-accessible | current | List of pm100gemuxsfpMondownRmonBroadcastCounterLineOutput Article |
| 1.3.6.1.4.1.20044.107.11.3.4.806.1 | Rowpm100gemuxsfpMondownRmonBroadcastCounterLineOutputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMondownRmonBroadcastCounterLineOutput table |
| 1.3.6.1.4.1.20044.107.11.3.4.806.1.1 | Columnpm100gemuxsfpMondownRmonBroadcastCounterLineOutputIndex | read-only | current | Index definition for the pm100gemuxsfpMondownRmonBroadcastCounterLineOutput table |
| 1.3.6.1.4.1.20044.107.11.3.4.806.1.2 | Columnpm100gemuxsfpMondownRmonBroadcastCounterLineOutputValuePortn | read-only | current | Line Output Broadcast Packets :This counter is increased each time a broadcast packet is transmitted on the Line port <Help> This counter gives the number of B… |
| 1.3.6.1.4.1.20044.107.11.3.4.806.1.3 | Columnpm100gemuxsfpMondownRmonBroadcastCounterLineOutputErrorPortn | read-only | current | Broadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on Line port |
| 1.3.6.1.4.1.20044.107.11.3.4.806.1.4 | Columnpm100gemuxsfpMondownRmonBroadcastCounterLineOutputOverloadPortn | read-only | current | Broadcast Counter Overload :This OID when set indicates a Broadcast counter overload on Line port |
| 1.3.6.1.4.1.20044.107.11.3.4.808 | Tablepm100gemuxsfpMondownRmonMulticastCounterLineOutputTable | not-accessible | current | List of pm100gemuxsfpMondownRmonMulticastCounterLineOutput Article |
| 1.3.6.1.4.1.20044.107.11.3.4.808.1 | Rowpm100gemuxsfpMondownRmonMulticastCounterLineOutputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMondownRmonMulticastCounterLineOutput table |
| 1.3.6.1.4.1.20044.107.11.3.4.808.1.1 | Columnpm100gemuxsfpMondownRmonMulticastCounterLineOutputIndex | read-only | current | Index definition for the pm100gemuxsfpMondownRmonMulticastCounterLineOutput table |
| 1.3.6.1.4.1.20044.107.11.3.4.808.1.2 | Columnpm100gemuxsfpMondownRmonMulticastCounterLineOutputValuePortn | read-only | current | Line Output Multicast Packets :This counter is increased each time a Multicast packet is transmitted on the Line port <Help> This counter gives the number of M… |
| 1.3.6.1.4.1.20044.107.11.3.4.808.1.3 | Columnpm100gemuxsfpMondownRmonMulticastCounterLineOutputErrorPortn | read-only | current | Multicast Counter Error :This OID when set indicates the Multicast counter value is invalid on Line port |
| 1.3.6.1.4.1.20044.107.11.3.4.808.1.4 | Columnpm100gemuxsfpMondownRmonMulticastCounterLineOutputOverloadPortn | read-only | current | Multicast Counter Overload :This OID when set indicates a Multicast counter overload on Line port |
| 1.3.6.1.4.1.20044.107.11.3.4.810 | Tablepm100gemuxsfpMondownRmonPauseFrameCounterLineOutputTable | not-accessible | current | List of pm100gemuxsfpMondownRmonPauseFrameCounterLineOutput Article |
| 1.3.6.1.4.1.20044.107.11.3.4.810.1 | Rowpm100gemuxsfpMondownRmonPauseFrameCounterLineOutputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMondownRmonPauseFrameCounterLineOutput table |
| 1.3.6.1.4.1.20044.107.11.3.4.810.1.1 | Columnpm100gemuxsfpMondownRmonPauseFrameCounterLineOutputIndex | read-only | current | Index definition for the pm100gemuxsfpMondownRmonPauseFrameCounterLineOutput table |
| 1.3.6.1.4.1.20044.107.11.3.4.810.1.2 | Columnpm100gemuxsfpMondownRmonPauseFrameCounterLineOutputValuePortn | read-only | current | Line Output Pause Frames :This counter is increased each time a Pause frame is transmitted on the Line port <Help> This counter gives the number of Pause frame… |
| 1.3.6.1.4.1.20044.107.11.3.4.810.1.3 | Columnpm100gemuxsfpMondownRmonPauseFrameCounterLineOutputErrorPortn | read-only | current | Pause Counter Error :This OID when set indicates the Pause counter value is invalid on Line port |
| 1.3.6.1.4.1.20044.107.11.3.4.810.1.4 | Columnpm100gemuxsfpMondownRmonPauseFrameCounterLineOutputOverloadPortn | read-only | current | Pause Counter Overload :This OID when set indicates a Pause counter overload on Line port |
| 1.3.6.1.4.1.20044.107.11.3.4.812 | Tablepm100gemuxsfpMondownRmonUnicastCounterLineOutputTable | not-accessible | current | List of pm100gemuxsfpMondownRmonUnicastCounterLineOutput Article |
| 1.3.6.1.4.1.20044.107.11.3.4.812.1 | Rowpm100gemuxsfpMondownRmonUnicastCounterLineOutputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMondownRmonUnicastCounterLineOutput table |
| 1.3.6.1.4.1.20044.107.11.3.4.812.1.1 | Columnpm100gemuxsfpMondownRmonUnicastCounterLineOutputIndex | read-only | current | Index definition for the pm100gemuxsfpMondownRmonUnicastCounterLineOutput table |
| 1.3.6.1.4.1.20044.107.11.3.4.812.1.2 | Columnpm100gemuxsfpMondownRmonUnicastCounterLineOutputValuePortn | read-only | current | Line Output Unicast Packets :This counter is increased each time a Unicast packet is transmitted on the Line port <Help> This counter gives the number of Unica… |
| 1.3.6.1.4.1.20044.107.11.3.4.812.1.3 | Columnpm100gemuxsfpMondownRmonUnicastCounterLineOutputErrorPortn | read-only | current | Unicast Counter Error :This OID when set indicates the Unicast counter value is invalid on Line port |
| 1.3.6.1.4.1.20044.107.11.3.4.812.1.4 | Columnpm100gemuxsfpMondownRmonUnicastCounterLineOutputOverloadPortn | read-only | current | Unicast Counter Overload :This OID when set indicates a Unicast counter overload on Line port |
| 1.3.6.1.4.1.20044.107.11.3.4.814 | Tablepm100gemuxsfpMondownRmonNonunicastCounterLineOutputTable | not-accessible | current | List of pm100gemuxsfpMondownRmonNonunicastCounterLineOutput Article |
| 1.3.6.1.4.1.20044.107.11.3.4.814.1 | Rowpm100gemuxsfpMondownRmonNonunicastCounterLineOutputEntry | not-accessible | current | Row definition for the pm100gemuxsfpMondownRmonNonunicastCounterLineOutput table |
| 1.3.6.1.4.1.20044.107.11.3.4.814.1.1 | Columnpm100gemuxsfpMondownRmonNonunicastCounterLineOutputIndex | read-only | current | Index definition for the pm100gemuxsfpMondownRmonNonunicastCounterLineOutput table |
| 1.3.6.1.4.1.20044.107.11.3.4.814.1.2 | Columnpm100gemuxsfpMondownRmonNonunicastCounterLineOutputValuePortn | read-only | current | Line Output Non Unicast Packets :This counter is increased each time a Non-Unicast packet is transmitted on the Line port <Help> This counter gives the number … |
| 1.3.6.1.4.1.20044.107.11.3.4.814.1.3 | Columnpm100gemuxsfpMondownRmonNonunicastCounterLineOutputErrorPortn | read-only | current | Non Unicast Counter Error :This OID when set indicates the Non-Unicast counter value is invalid on Line port |
| 1.3.6.1.4.1.20044.107.11.3.4.814.1.4 | Columnpm100gemuxsfpMondownRmonNonunicastCounterLineOutputOverloadPortn | read-only | current | Non Unicast Counter Overload :This OID when set indicates a Non-Unicast counter overload on Line port |
| 1.3.6.1.4.1.20044.107.11.5 | Nodepm100gemuxsfpMonPerfOther | |||
| 1.3.6.1.4.1.20044.107.11.5.1 | Nodepm100gemuxsfpMonPerfSync | |||
| 1.3.6.1.4.1.20044.107.11.5.1.257 | Scalarpm100gemuxsfpPerfEnable | read-write | current | Perf. Mon. Enable :This OID enables the Performance Monitoring application |
| 1.3.6.1.4.1.20044.107.11.5.1.259 | Scalarpm100gemuxsfpPerf15minSync | read-write | current | Perf. Mon. 15-min sync. :This OID must be used in external synchronisation mode only to send a 15-min synchronisation command |
| 1.3.6.1.4.1.20044.107.11.5.1.260 | Scalarpm100gemuxsfpPerf24hSync | read-write | current | Perf. Mon. 24-hours sync. :This OID must be used in external synchronisation mode only to send a 24-hours synchronisation command |
| 1.3.6.1.4.1.20044.107.11.5.2 | Nodepm100gemuxsfpMonPerfTimeStamp | |||
| 1.3.6.1.4.1.20044.107.11.5.2.1 | Scalarpm100gemuxsfpPerf15MinShort | read-write | current | 15-min period is short :This OID indicates that the 15-min period lasts less than 890 seconds |
| 1.3.6.1.4.1.20044.107.11.5.2.2 | Scalarpm100gemuxsfpPerf15MinLong | read-write | current | 15-min period is long :This OID indicates that the 15-min period lasts more than 910 seconds |
| 1.3.6.1.4.1.20044.107.11.5.2.5 | Scalarpm100gemuxsfpPerf24HoursShort | read-write | current | 24-hours period is short :This OID indicates that 24-hours period lasts less than 86390 seconds |
| 1.3.6.1.4.1.20044.107.11.5.2.6 | Scalarpm100gemuxsfpPerf24HoursLong | read-write | current | 24-hours period is long :This OID indicates that 24-hours period lasts more than 86410 seconds |
| 1.3.6.1.4.1.20044.107.11.5.2.7 | Scalarpm100gemuxsfpPerfCurrent15MinElapsedTime | read-write | current | Current 15min period Elapsed Time :This OID gives the number of seconds elapsed in the current 15-minutes period |
| 1.3.6.1.4.1.20044.107.11.5.2.8 | Scalarpm100gemuxsfpPerfCurrent24HoursElapsedTime | read-write | current | Current 24hours period Elapsed Time :This OID gives the number of seconds elapsed in the current 24-hours period |
| 1.3.6.1.4.1.20044.107.11.6 | Nodepm100gemuxsfpMonPerfClient | |||
| 1.3.6.1.4.1.20044.107.11.6.16 | Tablepm100gemuxsfpPerfTelecomInputClientCurrent15StatTable | not-accessible | current | List of pm100gemuxsfpPerfTelecomInputClientCurrent15Stat Article |
| 1.3.6.1.4.1.20044.107.11.6.16.1 | Rowpm100gemuxsfpPerfTelecomInputClientCurrent15StatEntry | not-accessible | current | Row definition for the pm100gemuxsfpPerfTelecomInputClientCurrent15Stat table |
| 1.3.6.1.4.1.20044.107.11.6.16.1.1 | Columnpm100gemuxsfpPerfTelecomInputClientCurrent15StatIndex | read-only | current | Index definition for the pm100gemuxsfpPerfTelecomInputClientCurrent15Stat table |
| 1.3.6.1.4.1.20044.107.11.6.16.1.2 | Columnpm100gemuxsfpPerfTelecomInputClientCurrent15StatInvCvPortn | read-only | current | Current 15-min EBC counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.16.1.3 | Columnpm100gemuxsfpPerfTelecomInputClientCurrent15StatCvValuePortn | read-only | current | Current 15-min EBC counter :This OID gives the current 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.107.11.6.16.1.4 | Columnpm100gemuxsfpPerfTelecomInputClientCurrent15StatInvEsPortn | read-only | current | Current 15-min ES counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.16.1.5 | Columnpm100gemuxsfpPerfTelecomInputClientCurrent15StatEsValuePortn | read-only | current | Current 15-min ES counter :This OID gives the current 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.16.1.6 | Columnpm100gemuxsfpPerfTelecomInputClientCurrent15StatInvSesPortn | read-only | current | Current 15-min SES counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.16.1.7 | Columnpm100gemuxsfpPerfTelecomInputClientCurrent15StatSesValuePortn | read-only | current | Current 15-min SES counter :This OID gives the current 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.16.1.8 | Columnpm100gemuxsfpPerfTelecomInputClientCurrent15StatInvSefsPortn | read-only | current | Current 15-min SEFS counter inv. :This OID indicates that the current 15-min severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.16.1.9 | Columnpm100gemuxsfpPerfTelecomInputClientCurrent15StatSefsValuePortn | read-only | current | Current 15-min SEFS counter :This OID gives the current 15-min severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.16.1.10 | Columnpm100gemuxsfpPerfTelecomInputClientCurrent15StatInvUasPortn | read-only | current | Current 15-min UAS counter inv. :This OID indicates that the current 15-min UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.16.1.11 | Columnpm100gemuxsfpPerfTelecomInputClientCurrent15StatUasValuePortn | read-only | current | Current 15-min UAS counter :This OID gives the current 15-min UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.48 | Tablepm100gemuxsfpPerfTelecomInputClientPast15StatHistoryPort1Table | not-accessible | current | List of pm100gemuxsfpPerfTelecomInputClientPast15StatHistory Article |
| 1.3.6.1.4.1.20044.107.11.6.48.1 | Rowpm100gemuxsfpPerfTelecomInputClientPast15StatHistoryPort1Entry | not-accessible | current | Row definition for the pm100gemuxsfpPerfTelecomInputClientPast15StatHistory table |
| 1.3.6.1.4.1.20044.107.11.6.48.1.1 | Columnpm100gemuxsfpPerfTelecomInputClientPast15StatHistoryPort1Index | read-only | current | Index definition for the pm100gemuxsfpPerfTelecomInputClientPast15StatHistory table |
| 1.3.6.1.4.1.20044.107.11.6.48.1.2 | Columnpm100gemuxsfpPerfTelecomInputClientPast15StatHistoryInvCvPort1 | read-only | current | Previous 15-min EBC counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.48.1.3 | Columnpm100gemuxsfpPerfTelecomInputClientPast15StatHistoryCvValuePort1 | read-only | current | Previous 15-min EBC counter :This OID gives the previous 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.107.11.6.48.1.4 | Columnpm100gemuxsfpPerfTelecomInputClientPast15StatHistoryInvEsPort1 | read-only | current | Previous 15-min ES counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.48.1.5 | Columnpm100gemuxsfpPerfTelecomInputClientPast15StatHistoryEsValuePort1 | read-only | current | Previous 15-min ES counter :This OID gives the previous 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.48.1.6 | Columnpm100gemuxsfpPerfTelecomInputClientPast15StatHistoryInvSesPort1 | read-only | current | Previous 15-min SES counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.48.1.7 | Columnpm100gemuxsfpPerfTelecomInputClientPast15StatHistorySesValuePort1 | read-only | current | Previous 15-min SES counter :This OID gives the previous 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.48.1.8 | Columnpm100gemuxsfpPerfTelecomInputClientPast15StatHistoryInvSefsPort1 | read-only | current | Previous 15-min SEFS counter inv. :This OID indicates that the previous 15-min severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.48.1.9 | Columnpm100gemuxsfpPerfTelecomInputClientPast15StatHistorySefsValuePort1 | read-only | current | Previous 15-min SEFS counter :This OID gives the previous 15-min severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.48.1.10 | Columnpm100gemuxsfpPerfTelecomInputClientPast15StatHistoryInvUasPort1 | read-only | current | Previous 15-min UAS counter inv. :This OID indicates that the previous 15-min UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.48.1.11 | Columnpm100gemuxsfpPerfTelecomInputClientPast15StatHistoryUasValuePort1 | read-only | current | Previous 15-min UAS counter :This OID gives the previous 15-min UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.80 | Tablepm100gemuxsfpPerfTelecomInputClientCurrent24StatTable | not-accessible | current | List of pm100gemuxsfpPerfTelecomInputClientCurrent24Stat Article |
| 1.3.6.1.4.1.20044.107.11.6.80.1 | Rowpm100gemuxsfpPerfTelecomInputClientCurrent24StatEntry | not-accessible | current | Row definition for the pm100gemuxsfpPerfTelecomInputClientCurrent24Stat table |
| 1.3.6.1.4.1.20044.107.11.6.80.1.1 | Columnpm100gemuxsfpPerfTelecomInputClientCurrent24StatIndex | read-only | current | Index definition for the pm100gemuxsfpPerfTelecomInputClientCurrent24Stat table |
| 1.3.6.1.4.1.20044.107.11.6.80.1.2 | Columnpm100gemuxsfpPerfTelecomInputClientCurrent24StatInvCvPortn | read-only | current | Current 24-hours EBC counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.80.1.3 | Columnpm100gemuxsfpPerfTelecomInputClientCurrent24StatCvValuePortn | read-only | current | Current 24-hours EBC counter :This OID gives the current 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.107.11.6.80.1.4 | Columnpm100gemuxsfpPerfTelecomInputClientCurrent24StatInvEsPortn | read-only | current | Current 24-hours ES counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.80.1.5 | Columnpm100gemuxsfpPerfTelecomInputClientCurrent24StatEsValuePortn | read-only | current | Current 24-hours ES counter :This OID gives the current 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.80.1.6 | Columnpm100gemuxsfpPerfTelecomInputClientCurrent24StatInvSesPortn | read-only | current | Current 24-hours SES counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.80.1.7 | Columnpm100gemuxsfpPerfTelecomInputClientCurrent24StatSesValuePortn | read-only | current | Current 24-hours SES counter :This OID gives the current 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.80.1.8 | Columnpm100gemuxsfpPerfTelecomInputClientCurrent24StatInvSefsPortn | read-only | current | Current 24-hours SEFS counter inv. :This OID indicates that the current 24-hours severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.80.1.9 | Columnpm100gemuxsfpPerfTelecomInputClientCurrent24StatSefsValuePortn | read-only | current | Current 24-hours SEFS counter :This OID gives the current 24-hours severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.80.1.10 | Columnpm100gemuxsfpPerfTelecomInputClientCurrent24StatInvUasPortn | read-only | current | Current 24-hours UAS counter inv. :This OID indicates that the current 24-hours UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.80.1.11 | Columnpm100gemuxsfpPerfTelecomInputClientCurrent24StatUasValuePortn | read-only | current | Current 24-hours UAS counter :This OID gives the current 24-hours UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.112 | Tablepm100gemuxsfpPerfTelecomInputClientPast24StatHistoryPort1Table | not-accessible | current | List of pm100gemuxsfpPerfTelecomInputClientPast24StatHistory Article |
| 1.3.6.1.4.1.20044.107.11.6.112.1 | Rowpm100gemuxsfpPerfTelecomInputClientPast24StatHistoryPort1Entry | not-accessible | current | Row definition for the pm100gemuxsfpPerfTelecomInputClientPast24StatHistory table |
| 1.3.6.1.4.1.20044.107.11.6.112.1.1 | Columnpm100gemuxsfpPerfTelecomInputClientPast24StatHistoryPort1Index | read-only | current | Index definition for the pm100gemuxsfpPerfTelecomInputClientPast24StatHistory table |
| 1.3.6.1.4.1.20044.107.11.6.112.1.2 | Columnpm100gemuxsfpPerfTelecomInputClientPast24StatHistoryInvCvPort1 | read-only | current | Previous 24-hours EBC counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.112.1.3 | Columnpm100gemuxsfpPerfTelecomInputClientPast24StatHistoryCvValuePort1 | read-only | current | Previous 24-hours EBC counter :This OID gives the previous 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.107.11.6.112.1.4 | Columnpm100gemuxsfpPerfTelecomInputClientPast24StatHistoryInvEsPort1 | read-only | current | Previous 24-hours ES counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.112.1.5 | Columnpm100gemuxsfpPerfTelecomInputClientPast24StatHistoryEsValuePort1 | read-only | current | Previous 24-hours ES counter :This OID gives the previous 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.112.1.6 | Columnpm100gemuxsfpPerfTelecomInputClientPast24StatHistoryInvSesPort1 | read-only | current | Previous 24-hours SES counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.112.1.7 | Columnpm100gemuxsfpPerfTelecomInputClientPast24StatHistorySesValuePort1 | read-only | current | Previous 24-hours SES counter :This OID gives the previous 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.112.1.8 | Columnpm100gemuxsfpPerfTelecomInputClientPast24StatHistoryInvSefsPort1 | read-only | current | Previous 24-hours SEFS counter inv. :This OID indicates that the previous 24-hours severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.112.1.9 | Columnpm100gemuxsfpPerfTelecomInputClientPast24StatHistorySefsValuePort1 | read-only | current | Previous 24-hours SEFS counter :This OID gives the previous 24-hours severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.112.1.10 | Columnpm100gemuxsfpPerfTelecomInputClientPast24StatHistoryInvUasPort1 | read-only | current | Previous 24-hours UAS counter inv. :This OID indicates that the previous 24-hours UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.112.1.11 | Columnpm100gemuxsfpPerfTelecomInputClientPast24StatHistoryUasValuePort1 | read-only | current | Previous 24-hours UAS counter :This OID gives the previous 24-hours UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.144 | Tablepm100gemuxsfpPerfTelecomOutputClientCurrent15StatTable | not-accessible | current | List of pm100gemuxsfpPerfTelecomOutputClientCurrent15Stat Article |
| 1.3.6.1.4.1.20044.107.11.6.144.1 | Rowpm100gemuxsfpPerfTelecomOutputClientCurrent15StatEntry | not-accessible | current | Row definition for the pm100gemuxsfpPerfTelecomOutputClientCurrent15Stat table |
| 1.3.6.1.4.1.20044.107.11.6.144.1.1 | Columnpm100gemuxsfpPerfTelecomOutputClientCurrent15StatIndex | read-only | current | Index definition for the pm100gemuxsfpPerfTelecomOutputClientCurrent15Stat table |
| 1.3.6.1.4.1.20044.107.11.6.144.1.2 | Columnpm100gemuxsfpPerfTelecomOutputClientCurrent15StatInvCvPortn | read-only | current | Current 15-min EBC counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.144.1.3 | Columnpm100gemuxsfpPerfTelecomOutputClientCurrent15StatCvValuePortn | read-only | current | Current 15-min EBC counter :This OID gives the current 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.107.11.6.144.1.4 | Columnpm100gemuxsfpPerfTelecomOutputClientCurrent15StatInvEsPortn | read-only | current | Current 15-min ES counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.144.1.5 | Columnpm100gemuxsfpPerfTelecomOutputClientCurrent15StatEsValuePortn | read-only | current | Current 15-min ES counter :This OID gives the current 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.144.1.6 | Columnpm100gemuxsfpPerfTelecomOutputClientCurrent15StatInvSesPortn | read-only | current | Current 15-min SES counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.144.1.7 | Columnpm100gemuxsfpPerfTelecomOutputClientCurrent15StatSesValuePortn | read-only | current | Current 15-min SES counter :This OID gives the current 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.144.1.8 | Columnpm100gemuxsfpPerfTelecomOutputClientCurrent15StatInvSefsPortn | read-only | current | Current 15-min SEFS counter inv. :This OID indicates that the current 15-min severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.144.1.9 | Columnpm100gemuxsfpPerfTelecomOutputClientCurrent15StatSefsValuePortn | read-only | current | Current 15-min SEFS counter :This OID gives the current 15-min severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.144.1.10 | Columnpm100gemuxsfpPerfTelecomOutputClientCurrent15StatInvUasPortn | read-only | current | Current 15-min UAS counter inv. :This OID indicates that the current 15-min UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.144.1.11 | Columnpm100gemuxsfpPerfTelecomOutputClientCurrent15StatUasValuePortn | read-only | current | Current 15-min UAS counter :This OID gives the current 15-min UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.176 | Tablepm100gemuxsfpPerfTelecomOutputClientPast15StatHistoryPort1Table | not-accessible | current | List of pm100gemuxsfpPerfTelecomOutputClientPast15StatHistory Article |
| 1.3.6.1.4.1.20044.107.11.6.176.1 | Rowpm100gemuxsfpPerfTelecomOutputClientPast15StatHistoryPort1Entry | not-accessible | current | Row definition for the pm100gemuxsfpPerfTelecomOutputClientPast15StatHistory table |
| 1.3.6.1.4.1.20044.107.11.6.176.1.1 | Columnpm100gemuxsfpPerfTelecomOutputClientPast15StatHistoryPort1Index | read-only | current | Index definition for the pm100gemuxsfpPerfTelecomOutputClientPast15StatHistory table |
| 1.3.6.1.4.1.20044.107.11.6.176.1.2 | Columnpm100gemuxsfpPerfTelecomOutputClientPast15StatHistoryInvCvPort1 | read-only | current | Previous 15-min EBC counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.176.1.3 | Columnpm100gemuxsfpPerfTelecomOutputClientPast15StatHistoryCvValuePort1 | read-only | current | Previous 15-min EBC counter :This OID gives the previous 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.107.11.6.176.1.4 | Columnpm100gemuxsfpPerfTelecomOutputClientPast15StatHistoryInvEsPort1 | read-only | current | Previous 15-min ES counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.176.1.5 | Columnpm100gemuxsfpPerfTelecomOutputClientPast15StatHistoryEsValuePort1 | read-only | current | Previous 15-min ES counter :This OID gives the previous 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.176.1.6 | Columnpm100gemuxsfpPerfTelecomOutputClientPast15StatHistoryInvSesPort1 | read-only | current | Previous 15-min SES counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.176.1.7 | Columnpm100gemuxsfpPerfTelecomOutputClientPast15StatHistorySesValuePort1 | read-only | current | Previous 15-min SES counter :This OID gives the previous 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.176.1.8 | Columnpm100gemuxsfpPerfTelecomOutputClientPast15StatHistoryInvSefsPort1 | read-only | current | Previous 15-min SEFS counter inv. :This OID indicates that the previous 15-min severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.176.1.9 | Columnpm100gemuxsfpPerfTelecomOutputClientPast15StatHistorySefsValuePort1 | read-only | current | Previous 15-min SEFS counter :This OID gives the previous 15-min severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.176.1.10 | Columnpm100gemuxsfpPerfTelecomOutputClientPast15StatHistoryInvUasPort1 | read-only | current | Previous 15-min UAS counter inv. :This OID indicates that the previous 15-min UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.176.1.11 | Columnpm100gemuxsfpPerfTelecomOutputClientPast15StatHistoryUasValuePort1 | read-only | current | Previous 15-min UAS counter :This OID gives the previous 15-min UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.208 | Tablepm100gemuxsfpPerfTelecomOutputClientCurrent24StatTable | not-accessible | current | List of pm100gemuxsfpPerfTelecomOutputClientCurrent24Stat Article |
| 1.3.6.1.4.1.20044.107.11.6.208.1 | Rowpm100gemuxsfpPerfTelecomOutputClientCurrent24StatEntry | not-accessible | current | Row definition for the pm100gemuxsfpPerfTelecomOutputClientCurrent24Stat table |
| 1.3.6.1.4.1.20044.107.11.6.208.1.1 | Columnpm100gemuxsfpPerfTelecomOutputClientCurrent24StatIndex | read-only | current | Index definition for the pm100gemuxsfpPerfTelecomOutputClientCurrent24Stat table |
| 1.3.6.1.4.1.20044.107.11.6.208.1.2 | Columnpm100gemuxsfpPerfTelecomOutputClientCurrent24StatInvCvPortn | read-only | current | Current 24-hours EBC counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.208.1.3 | Columnpm100gemuxsfpPerfTelecomOutputClientCurrent24StatCvValuePortn | read-only | current | Current 24-hours EBC counter :This OID gives the current 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.107.11.6.208.1.4 | Columnpm100gemuxsfpPerfTelecomOutputClientCurrent24StatInvEsPortn | read-only | current | Current 24-hours ES counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.208.1.5 | Columnpm100gemuxsfpPerfTelecomOutputClientCurrent24StatEsValuePortn | read-only | current | Current 24-hours ES counter :This OID gives the current 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.208.1.6 | Columnpm100gemuxsfpPerfTelecomOutputClientCurrent24StatInvSesPortn | read-only | current | Current 24-hours SES counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.208.1.7 | Columnpm100gemuxsfpPerfTelecomOutputClientCurrent24StatSesValuePortn | read-only | current | Current 24-hours SES counter :This OID gives the current 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.208.1.8 | Columnpm100gemuxsfpPerfTelecomOutputClientCurrent24StatInvSefsPortn | read-only | current | Current 24-hours SEFS counter inv. :This OID indicates that the current 24-hours severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.208.1.9 | Columnpm100gemuxsfpPerfTelecomOutputClientCurrent24StatSefsValuePortn | read-only | current | Current 24-hours SEFS counter :This OID gives the current 24-hours severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.208.1.10 | Columnpm100gemuxsfpPerfTelecomOutputClientCurrent24StatInvUasPortn | read-only | current | Current 24-hours UAS counter inv. :This OID indicates that the current 24-hours UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.208.1.11 | Columnpm100gemuxsfpPerfTelecomOutputClientCurrent24StatUasValuePortn | read-only | current | Current 24-hours UAS counter :This OID gives the current 24-hours UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.240 | Tablepm100gemuxsfpPerfTelecomOutputClientPast24StatHistoryPort1Table | not-accessible | current | List of pm100gemuxsfpPerfTelecomOutputClientPast24StatHistory Article |
| 1.3.6.1.4.1.20044.107.11.6.240.1 | Rowpm100gemuxsfpPerfTelecomOutputClientPast24StatHistoryPort1Entry | not-accessible | current | Row definition for the pm100gemuxsfpPerfTelecomOutputClientPast24StatHistory table |
| 1.3.6.1.4.1.20044.107.11.6.240.1.1 | Columnpm100gemuxsfpPerfTelecomOutputClientPast24StatHistoryPort1Index | read-only | current | Index definition for the pm100gemuxsfpPerfTelecomOutputClientPast24StatHistory table |
| 1.3.6.1.4.1.20044.107.11.6.240.1.2 | Columnpm100gemuxsfpPerfTelecomOutputClientPast24StatHistoryInvCvPort1 | read-only | current | Previous 24-hours EBC counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.240.1.3 | Columnpm100gemuxsfpPerfTelecomOutputClientPast24StatHistoryCvValuePort1 | read-only | current | Previous 24-hours EBC counter :This OID gives the previous 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.107.11.6.240.1.4 | Columnpm100gemuxsfpPerfTelecomOutputClientPast24StatHistoryInvEsPort1 | read-only | current | Previous 24-hours ES counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.240.1.5 | Columnpm100gemuxsfpPerfTelecomOutputClientPast24StatHistoryEsValuePort1 | read-only | current | Previous 24-hours ES counter :This OID gives the previous 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.240.1.6 | Columnpm100gemuxsfpPerfTelecomOutputClientPast24StatHistoryInvSesPort1 | read-only | current | Previous 24-hours SES counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.240.1.7 | Columnpm100gemuxsfpPerfTelecomOutputClientPast24StatHistorySesValuePort1 | read-only | current | Previous 24-hours SES counter :This OID gives the previous 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.240.1.8 | Columnpm100gemuxsfpPerfTelecomOutputClientPast24StatHistoryInvSefsPort1 | read-only | current | Previous 24-hours SEFS counter inv. :This OID indicates that the previous 24-hours severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.240.1.9 | Columnpm100gemuxsfpPerfTelecomOutputClientPast24StatHistorySefsValuePort1 | read-only | current | Previous 24-hours SEFS counter :This OID gives the previous 24-hours severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.240.1.10 | Columnpm100gemuxsfpPerfTelecomOutputClientPast24StatHistoryInvUasPort1 | read-only | current | Previous 24-hours UAS counter inv. :This OID indicates that the previous 24-hours UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.240.1.11 | Columnpm100gemuxsfpPerfTelecomOutputClientPast24StatHistoryUasValuePort1 | read-only | current | Previous 24-hours UAS counter :This OID gives the previous 24-hours UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.107.11.6.848 | Tablepm100gemuxsfpPerfDatacomClientCurrent15StatTable | not-accessible | current | List of pm100gemuxsfpPerfDatacomClientCurrent15Stat Article |
| 1.3.6.1.4.1.20044.107.11.6.848.1 | Rowpm100gemuxsfpPerfDatacomClientCurrent15StatEntry | not-accessible | current | Row definition for the pm100gemuxsfpPerfDatacomClientCurrent15Stat table |
| 1.3.6.1.4.1.20044.107.11.6.848.1.1 | Columnpm100gemuxsfpPerfDatacomClientCurrent15StatIndex | read-only | current | Index definition for the pm100gemuxsfpPerfDatacomClientCurrent15Stat table |
| 1.3.6.1.4.1.20044.107.11.6.848.1.4 | Columnpm100gemuxsfpperfdatacomclientCurrent15StatInCrcCountInvPortn | read-only | current | Client Current 15-min Input CRC counter inv. :This OID indicates that the current 15-min Input CRC counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.848.1.5 | Columnpm100gemuxsfpperfdatacomclientCurrent15StatInCrcCountPortn | read-only | current | Client Current 15-min Input CRC counter :This OID gives the current 15-min Input CRC counter value |
| 1.3.6.1.4.1.20044.107.11.6.848.1.6 | Columnpm100gemuxsfpperfdatacomclientCurrent15StatInPacketCountInvPortn | read-only | current | Client Current 15-min Input Packet counter inv. :This OID indicates that the current 15-min Input Packet counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.848.1.7 | Columnpm100gemuxsfpperfdatacomclientCurrent15StatInPacketCountPortn | read-only | current | Client Current 15-min Input Packet counter :This OID gives the current 15-min Input Packet counter value |
| 1.3.6.1.4.1.20044.107.11.6.848.1.28 | Columnpm100gemuxsfpperfdatacomclientCurrent15StatOutCrcCountInvPortn | read-only | current | Client Current 15-min Output CRC counter inv. :This OID indicates that the current 15-min Output CRC counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.848.1.29 | Columnpm100gemuxsfpperfdatacomclientCurrent15StatOutCrcCountPortn | read-only | current | Client Current 15-min Output CRC counter :This OID gives the current 15-min Output CRC counter value |
| 1.3.6.1.4.1.20044.107.11.6.848.1.30 | Columnpm100gemuxsfpperfdatacomclientCurrent15StatOutPacketCountInvPortn | read-only | current | Client Current 15-min Output Packet counter inv. :This OID indicates that the current 15-min Output Packets counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.848.1.31 | Columnpm100gemuxsfpperfdatacomclientCurrent15StatOutPacketCountPortn | read-only | current | Client Current 15-min Output Packet counter :This OID gives the current 15-min Output Packets counter value |
| 1.3.6.1.4.1.20044.107.11.6.880 | Tablepm100gemuxsfpPerfDatacomClientPast15StatHistoryPort1Table | not-accessible | current | List of pm100gemuxsfpPerfDatacomClientPast15StatHistory Article |
| 1.3.6.1.4.1.20044.107.11.6.880.1 | Rowpm100gemuxsfpPerfDatacomClientPast15StatHistoryPort1Entry | not-accessible | current | Row definition for the pm100gemuxsfpPerfDatacomClientPast15StatHistory table |
| 1.3.6.1.4.1.20044.107.11.6.880.1.1 | Columnpm100gemuxsfpPerfDatacomClientPast15StatHistoryPort1Index | read-only | current | Index definition for the pm100gemuxsfpPerfDatacomClientPast15StatHistory table |
| 1.3.6.1.4.1.20044.107.11.6.880.1.4 | Columnpm100gemuxsfpperfdatacomclientPast15StatInCrcCountInvPort1 | read-only | current | Client Past 15-min Input CRC counter inv. :This OID indicates that the past 15-min Input CRC counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.880.1.5 | Columnpm100gemuxsfpperfdatacomclientPast15StatInCrcCountPort1 | read-only | current | Client Past 15-min Input CRC counter :This OID gives the past 15-min Input CRC counter value |
| 1.3.6.1.4.1.20044.107.11.6.880.1.6 | Columnpm100gemuxsfpperfdatacomclientPast15StatInPacketCountInvPort1 | read-only | current | Client Past 15-min Input Packet counter inv. :This OID indicates that the past 15-min Input Packet counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.880.1.7 | Columnpm100gemuxsfpperfdatacomclientPast15StatInPacketCountPort1 | read-only | current | Client Past 15-min Input Packet counter :This OID gives the past 15-min Input Packet counter value |
| 1.3.6.1.4.1.20044.107.11.6.880.1.28 | Columnpm100gemuxsfpperfdatacomclientPast15StatOutCrcCountInvPort1 | read-only | current | Client Past 15-min Output CRC counter inv. :This OID indicates that the past 15-min Output CRC counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.880.1.29 | Columnpm100gemuxsfpperfdatacomclientPast15StatOutCrcCountPort1 | read-only | current | Client Past 15-min Output CRC counter :This OID gives the past 15-min Output CRC counter value |
| 1.3.6.1.4.1.20044.107.11.6.880.1.30 | Columnpm100gemuxsfpperfdatacomclientPast15StatOutPacketCountInvPort1 | read-only | current | Client Past 15-min Output Packet counter inv. :This OID indicates that the past 15-min Output Packets counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.880.1.31 | Columnpm100gemuxsfpperfdatacomclientPast15StatOutPacketCountPort1 | read-only | current | Client Past 15-min Output Packet counter :This OID gives the past 15-min Output Packets counter value |
| 1.3.6.1.4.1.20044.107.11.6.912 | Tablepm100gemuxsfpPerfDatacomClientCurrent24StatTable | not-accessible | current | List of pm100gemuxsfpPerfDatacomClientCurrent24Stat Article |
| 1.3.6.1.4.1.20044.107.11.6.912.1 | Rowpm100gemuxsfpPerfDatacomClientCurrent24StatEntry | not-accessible | current | Row definition for the pm100gemuxsfpPerfDatacomClientCurrent24Stat table |
| 1.3.6.1.4.1.20044.107.11.6.912.1.1 | Columnpm100gemuxsfpPerfDatacomClientCurrent24StatIndex | read-only | current | Index definition for the pm100gemuxsfpPerfDatacomClientCurrent24Stat table |
| 1.3.6.1.4.1.20044.107.11.6.912.1.4 | Columnpm100gemuxsfpperfdatacomclientCurrent24StatInCrcCountInvPortn | read-only | current | Client Current 24-hours Input CRC counter inv. :This OID indicates that the current 24-hours Input CRC counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.912.1.5 | Columnpm100gemuxsfpperfdatacomclientCurrent24StatInCrcCountPortn | read-only | current | Client Current 24-hours Input CRC counter :This OID gives the current 24-hours Input CRC counter value |
| 1.3.6.1.4.1.20044.107.11.6.912.1.6 | Columnpm100gemuxsfpperfdatacomclientCurrent24StatInPacketCountInvPortn | read-only | current | Client Current 24-hours Input Packet counter inv. :This OID indicates that the current 24-hours Input Packet counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.912.1.7 | Columnpm100gemuxsfpperfdatacomclientCurrent24StatInPacketCountPortn | read-only | current | Client Current 24-hours Input Packet counter :This OID gives the current 24-hours Input Packet counter value |
| 1.3.6.1.4.1.20044.107.11.6.912.1.28 | Columnpm100gemuxsfpperfdatacomclientCurrent24StatOutCrcCountInvPortn | read-only | current | Client Current 24-hours Output CRC counter inv. :This OID indicates that the current 24-hours Output CRC counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.912.1.29 | Columnpm100gemuxsfpperfdatacomclientCurrent24StatOutCrcCountPortn | read-only | current | Client Current 24-hours Output CRC counter :This OID gives the current 24-hours Output CRC counter value |
| 1.3.6.1.4.1.20044.107.11.6.912.1.30 | Columnpm100gemuxsfpperfdatacomclientCurrent24StatOutPacketCountInvPortn | read-only | current | Client Current 24-hours Output Packet counter inv. :This OID indicates that the current 24-hours Output Packets counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.912.1.31 | Columnpm100gemuxsfpperfdatacomclientCurrent24StatOutPacketCountPortn | read-only | current | Client Current 24-hours Output Packet counter :This OID gives the current 24-hours Output Packets counter value |
| 1.3.6.1.4.1.20044.107.11.6.944 | Tablepm100gemuxsfpPerfDatacomClientPast24StatHistoryPort1Table | not-accessible | current | List of pm100gemuxsfpPerfDatacomClientPast24StatHistory Article |
| 1.3.6.1.4.1.20044.107.11.6.944.1 | Rowpm100gemuxsfpPerfDatacomClientPast24StatHistoryPort1Entry | not-accessible | current | Row definition for the pm100gemuxsfpPerfDatacomClientPast24StatHistory table |
| 1.3.6.1.4.1.20044.107.11.6.944.1.1 | Columnpm100gemuxsfpPerfDatacomClientPast24StatHistoryPort1Index | read-only | current | Index definition for the pm100gemuxsfpPerfDatacomClientPast24StatHistory table |
| 1.3.6.1.4.1.20044.107.11.6.944.1.4 | Columnpm100gemuxsfpperfdatacomclientPast24StatInCrcCountInvPort1 | read-only | current | Client Past 24-hours Input CRC counter inv. :This OID indicates that the past 24-hours Input CRC counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.944.1.5 | Columnpm100gemuxsfpperfdatacomclientPast24StatInCrcCountPort1 | read-only | current | Client Past 24-hours Input CRC counter :This OID gives the past 24-hours Input CRC counter value |
| 1.3.6.1.4.1.20044.107.11.6.944.1.6 | Columnpm100gemuxsfpperfdatacomclientPast24StatInPacketCountInvPort1 | read-only | current | Client Past 24-hours Input Packet counter inv. :This OID indicates that the past 24-hours Input Packet counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.944.1.7 | Columnpm100gemuxsfpperfdatacomclientPast24StatInPacketCountPort1 | read-only | current | Client Past 24-hours Input Packet counter :This OID gives the past 24-hours Input Packet counter value |
| 1.3.6.1.4.1.20044.107.11.6.944.1.28 | Columnpm100gemuxsfpperfdatacomclientPast24StatOutCrcCountInvPort1 | read-only | current | Client Past 24-hours Output CRC counter inv. :This OID indicates that the past 24-hours Output CRC counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.944.1.29 | Columnpm100gemuxsfpperfdatacomclientPast24StatOutCrcCountPort1 | read-only | current | Client Past 24-hours Output CRC counter :This OID gives the past 24-hours Output CRC counter value |
| 1.3.6.1.4.1.20044.107.11.6.944.1.30 | Columnpm100gemuxsfpperfdatacomclientPast24StatOutPacketCountInvPort1 | read-only | current | Client Past 24-hours Output Packet counter inv. :This OID indicates that the past 24-hours Output Packets counter is invalid |
| 1.3.6.1.4.1.20044.107.11.6.944.1.31 | Columnpm100gemuxsfpperfdatacomclientPast24StatOutPacketCountPort1 | read-only | current | Client Past 24-hours Output Packet counter :This OID gives the past 24-hours Output Packets counter value |
| 1.3.6.1.4.1.20044.107.11.7 | Nodepm100gemuxsfpMonPerfLine | |||
| 1.3.6.1.4.1.20044.107.11.7.336 | Tablepm100gemuxsfpPerfTelecomLinePostFecCurrent15StatTable | not-accessible | current | List of pm100gemuxsfpPerfTelecomLinePostFecCurrent15Stat Article |
| 1.3.6.1.4.1.20044.107.11.7.336.1 | Rowpm100gemuxsfpPerfTelecomLinePostFecCurrent15StatEntry | not-accessible | current | Row definition for the pm100gemuxsfpPerfTelecomLinePostFecCurrent15Stat table |
| 1.3.6.1.4.1.20044.107.11.7.336.1.1 | Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent15StatIndex | read-only | current | Index definition for the pm100gemuxsfpPerfTelecomLinePostFecCurrent15Stat table |
| 1.3.6.1.4.1.20044.107.11.7.336.1.2 | Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent15StatInvCvPortn | read-only | current | Current 15-min EBC counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.336.1.3 | Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent15StatCvValuePortn | read-only | current | Current 15-min EBC counter :This OID gives the current 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.107.11.7.336.1.4 | Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent15StatInvEsPortn | read-only | current | Current 15-min ES counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.336.1.5 | Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent15StatEsValuePortn | read-only | current | Current 15-min ES counter :This OID gives the current 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.107.11.7.336.1.6 | Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent15StatInvSesPortn | read-only | current | Current 15-min SES counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.336.1.7 | Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent15StatSesValuePortn | read-only | current | Current 15-min SES counter :This OID gives the current 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.107.11.7.336.1.8 | Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent15StatInvSefsPortn | read-only | current | Current 15-min SEFS counter inv. :This OID indicates that the current 15-min severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.336.1.9 | Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent15StatSefsValuePortn | read-only | current | Current 15-min SEFS counter :This OID gives the current 15-min severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.107.11.7.336.1.10 | Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent15StatInvUasPortn | read-only | current | Current 15-min UAS counter inv. :This OID indicates that the current 15-min UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.336.1.11 | Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent15StatUasValuePortn | read-only | current | Current 15-min UAS counter :This OID gives the current 15-min UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.107.11.7.337 | Tablepm100gemuxsfpPerfTelecomLinePostFecPast15StatHistoryPort1Table | not-accessible | current | List of pm100gemuxsfpPerfTelecomLinePostFecPast15StatHistory Article |
| 1.3.6.1.4.1.20044.107.11.7.337.1 | Rowpm100gemuxsfpPerfTelecomLinePostFecPast15StatHistoryPort1Entry | not-accessible | current | Row definition for the pm100gemuxsfpPerfTelecomLinePostFecPast15StatHistory table |
| 1.3.6.1.4.1.20044.107.11.7.337.1.1 | Columnpm100gemuxsfpPerfTelecomLinePostFecPast15StatHistoryPort1Index | read-only | current | Index definition for the pm100gemuxsfpPerfTelecomLinePostFecPast15StatHistory table |
| 1.3.6.1.4.1.20044.107.11.7.337.1.2 | Columnpm100gemuxsfpPerfTelecomLinePostFecPast15StatHistoryInvCvPort1 | read-only | current | Previous 15-min EBC counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.337.1.3 | Columnpm100gemuxsfpPerfTelecomLinePostFecPast15StatHistoryCvValuePort1 | read-only | current | Previous 15-min EBC counter :This OID gives the previous 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.107.11.7.337.1.4 | Columnpm100gemuxsfpPerfTelecomLinePostFecPast15StatHistoryInvEsPort1 | read-only | current | Previous 15-min ES counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.337.1.5 | Columnpm100gemuxsfpPerfTelecomLinePostFecPast15StatHistoryEsValuePort1 | read-only | current | Previous 15-min ES counter :This OID gives the previous 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.107.11.7.337.1.6 | Columnpm100gemuxsfpPerfTelecomLinePostFecPast15StatHistoryInvSesPort1 | read-only | current | Previous 15-min SES counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.337.1.7 | Columnpm100gemuxsfpPerfTelecomLinePostFecPast15StatHistorySesValuePort1 | read-only | current | Previous 15-min SES counter :This OID gives the previous 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.107.11.7.337.1.8 | Columnpm100gemuxsfpPerfTelecomLinePostFecPast15StatHistoryInvSefsPort1 | read-only | current | Previous 15-min SEFS counter inv. :This OID indicates that the previous 15-min severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.337.1.9 | Columnpm100gemuxsfpPerfTelecomLinePostFecPast15StatHistorySefsValuePort1 | read-only | current | Previous 15-min SEFS counter :This OID gives the previous 15-min severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.107.11.7.337.1.10 | Columnpm100gemuxsfpPerfTelecomLinePostFecPast15StatHistoryInvUasPort1 | read-only | current | Previous 15-min UAS counter inv. :This OID indicates that the previous 15-min UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.337.1.11 | Columnpm100gemuxsfpPerfTelecomLinePostFecPast15StatHistoryUasValuePort1 | read-only | current | Previous 15-min UAS counter :This OID gives the previous 15-min UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.107.11.7.338 | Tablepm100gemuxsfpPerfTelecomLinePostFecCurrent24StatTable | not-accessible | current | List of pm100gemuxsfpPerfTelecomLinePostFecCurrent24Stat Article |
| 1.3.6.1.4.1.20044.107.11.7.338.1 | Rowpm100gemuxsfpPerfTelecomLinePostFecCurrent24StatEntry | not-accessible | current | Row definition for the pm100gemuxsfpPerfTelecomLinePostFecCurrent24Stat table |
| 1.3.6.1.4.1.20044.107.11.7.338.1.1 | Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent24StatIndex | read-only | current | Index definition for the pm100gemuxsfpPerfTelecomLinePostFecCurrent24Stat table |
| 1.3.6.1.4.1.20044.107.11.7.338.1.2 | Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent24StatInvCvPortn | read-only | current | Current 24-hours EBC counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.338.1.3 | Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent24StatCvValuePortn | read-only | current | Current 24-hours EBC counter :This OID gives the current 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.107.11.7.338.1.4 | Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent24StatInvEsPortn | read-only | current | Current 24-hours ES counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.338.1.5 | Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent24StatEsValuePortn | read-only | current | Current 24-hours ES counter :This OID gives the current 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.107.11.7.338.1.6 | Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent24StatInvSesPortn | read-only | current | Current 24-hours SES counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.338.1.7 | Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent24StatSesValuePortn | read-only | current | Current 24-hours SES counter :This OID gives the current 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.107.11.7.338.1.8 | Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent24StatInvSefsPortn | read-only | current | Current 24-hours SEFS counter inv. :This OID indicates that the current 24-hours severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.338.1.9 | Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent24StatSefsValuePortn | read-only | current | Current 24-hours SEFS counter :This OID gives the current 24-hours severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.107.11.7.338.1.10 | Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent24StatInvUasPortn | read-only | current | Current 24-hours UAS counter inv. :This OID indicates that the current 24-hours UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.338.1.11 | Columnpm100gemuxsfpPerfTelecomLinePostFecCurrent24StatUasValuePortn | read-only | current | Current 24-hours UAS counter :This OID gives the current 24-hours UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.107.11.7.339 | Tablepm100gemuxsfpPerfTelecomLinePostFecPast24StatHistoryPort1Table | not-accessible | current | List of pm100gemuxsfpPerfTelecomLinePostFecPast24StatHistory Article |
| 1.3.6.1.4.1.20044.107.11.7.339.1 | Rowpm100gemuxsfpPerfTelecomLinePostFecPast24StatHistoryPort1Entry | not-accessible | current | Row definition for the pm100gemuxsfpPerfTelecomLinePostFecPast24StatHistory table |
| 1.3.6.1.4.1.20044.107.11.7.339.1.1 | Columnpm100gemuxsfpPerfTelecomLinePostFecPast24StatHistoryPort1Index | read-only | current | Index definition for the pm100gemuxsfpPerfTelecomLinePostFecPast24StatHistory table |
| 1.3.6.1.4.1.20044.107.11.7.339.1.2 | Columnpm100gemuxsfpPerfTelecomLinePostFecPast24StatHistoryInvCvPort1 | read-only | current | Previous 24-hours EBC counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.339.1.3 | Columnpm100gemuxsfpPerfTelecomLinePostFecPast24StatHistoryCvValuePort1 | read-only | current | Previous 24-hours EBC counter :This OID gives the previous 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.107.11.7.339.1.4 | Columnpm100gemuxsfpPerfTelecomLinePostFecPast24StatHistoryInvEsPort1 | read-only | current | Previous 24-hours ES counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.339.1.5 | Columnpm100gemuxsfpPerfTelecomLinePostFecPast24StatHistoryEsValuePort1 | read-only | current | Previous 24-hours ES counter :This OID gives the previous 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.107.11.7.339.1.6 | Columnpm100gemuxsfpPerfTelecomLinePostFecPast24StatHistoryInvSesPort1 | read-only | current | Previous 24-hours SES counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.339.1.7 | Columnpm100gemuxsfpPerfTelecomLinePostFecPast24StatHistorySesValuePort1 | read-only | current | Previous 24-hours SES counter :This OID gives the previous 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.107.11.7.339.1.8 | Columnpm100gemuxsfpPerfTelecomLinePostFecPast24StatHistoryInvSefsPort1 | read-only | current | Previous 24-hours SEFS counter inv. :This OID indicates that the previous 24-hours severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.339.1.9 | Columnpm100gemuxsfpPerfTelecomLinePostFecPast24StatHistorySefsValuePort1 | read-only | current | Previous 24-hours SEFS counter :This OID gives the previous 24-hours severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.107.11.7.339.1.10 | Columnpm100gemuxsfpPerfTelecomLinePostFecPast24StatHistoryInvUasPort1 | read-only | current | Previous 24-hours UAS counter inv. :This OID indicates that the previous 24-hours UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.339.1.11 | Columnpm100gemuxsfpPerfTelecomLinePostFecPast24StatHistoryUasValuePort1 | read-only | current | Previous 24-hours UAS counter :This OID gives the previous 24-hours UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.107.11.7.352 | Tablepm100gemuxsfpPerfTelecomBerLinePreFecCurrent15StatTable | not-accessible | current | List of pm100gemuxsfpPerfTelecomBerLinePreFecCurrent15Stat Article |
| 1.3.6.1.4.1.20044.107.11.7.352.1 | Rowpm100gemuxsfpPerfTelecomBerLinePreFecCurrent15StatEntry | not-accessible | current | Row definition for the pm100gemuxsfpPerfTelecomBerLinePreFecCurrent15Stat table |
| 1.3.6.1.4.1.20044.107.11.7.352.1.1 | Columnpm100gemuxsfpPerfTelecomBerLinePreFecCurrent15StatIndex | read-only | current | Index definition for the pm100gemuxsfpPerfTelecomBerLinePreFecCurrent15Stat table |
| 1.3.6.1.4.1.20044.107.11.7.352.1.2 | Columnpm100gemuxsfpPerfTelecomBerLinePreFecCurrent15StatInvBerPortn | read-only | current | Current 15-min BER counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.352.1.3 | Columnpm100gemuxsfpPerfTelecomBerLinePreFecCurrent15StatBerValuePortn | read-only | current | Current 15-min BER counter :This OID gives the current 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.107.11.7.352.1.4 | Columnpm100gemuxsfpPerfTelecomBerLinePreFecCurrent15StatInvMinBerPortn | read-only | current | Current 15-min MinBER counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.352.1.5 | Columnpm100gemuxsfpPerfTelecomBerLinePreFecCurrent15StatMinBerValuePortn | read-only | current | Current 15-min MinBER counter :This OID gives the current 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.107.11.7.352.1.6 | Columnpm100gemuxsfpPerfTelecomBerLinePreFecCurrent15StatInvMaxBerPortn | read-only | current | Current 15-min MaxBER counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.352.1.7 | Columnpm100gemuxsfpPerfTelecomBerLinePreFecCurrent15StatMaxBerValuePortn | read-only | current | Current 15-min MaxBER counter :This OID gives the current 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.107.11.7.353 | Tablepm100gemuxsfpPerfTelecomBerLinePreFecPast15StatHistoryPort1Table | not-accessible | current | List of pm100gemuxsfpPerfTelecomBerLinePreFecPast15StatHistory Article |
| 1.3.6.1.4.1.20044.107.11.7.353.1 | Rowpm100gemuxsfpPerfTelecomBerLinePreFecPast15StatHistoryPort1Entry | not-accessible | current | Row definition for the pm100gemuxsfpPerfTelecomBerLinePreFecPast15StatHistory table |
| 1.3.6.1.4.1.20044.107.11.7.353.1.1 | Columnpm100gemuxsfpPerfTelecomBerLinePreFecPast15StatHistoryPort1Index | read-only | current | Index definition for the pm100gemuxsfpPerfTelecomBerLinePreFecPast15StatHistory table |
| 1.3.6.1.4.1.20044.107.11.7.353.1.2 | Columnpm100gemuxsfpPerfTelecomBerLinePreFecPast15StatHistoryInvBerPort1 | read-only | current | Previous 15-min BER counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.353.1.3 | Columnpm100gemuxsfpPerfTelecomBerLinePreFecPast15StatHistoryBerValuePort1 | read-only | current | Previous 15-min BER counter :This OID gives the previous 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.107.11.7.353.1.4 | Columnpm100gemuxsfpPerfTelecomBerLinePreFecPast15StatHistoryInvMinBerPort1 | read-only | current | Previous 15-min MinBER counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.353.1.5 | Columnpm100gemuxsfpPerfTelecomBerLinePreFecPast15StatHistoryMinBerValuePort1 | read-only | current | Previous 15-min MinBER counter :This OID gives the previous 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.107.11.7.353.1.6 | Columnpm100gemuxsfpPerfTelecomBerLinePreFecPast15StatHistoryInvMaxBerPort1 | read-only | current | Previous 15-min MaxBER counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.353.1.7 | Columnpm100gemuxsfpPerfTelecomBerLinePreFecPast15StatHistoryMaxBerValuePort1 | read-only | current | Previous 15-min MaxBER counter :This OID gives the previous 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.107.11.7.354 | Tablepm100gemuxsfpPerfTelecomBerLinePreFecCurrent24StatTable | not-accessible | current | List of pm100gemuxsfpPerfTelecomBerLinePreFecCurrent24Stat Article |
| 1.3.6.1.4.1.20044.107.11.7.354.1 | Rowpm100gemuxsfpPerfTelecomBerLinePreFecCurrent24StatEntry | not-accessible | current | Row definition for the pm100gemuxsfpPerfTelecomBerLinePreFecCurrent24Stat table |
| 1.3.6.1.4.1.20044.107.11.7.354.1.1 | Columnpm100gemuxsfpPerfTelecomBerLinePreFecCurrent24StatIndex | read-only | current | Index definition for the pm100gemuxsfpPerfTelecomBerLinePreFecCurrent24Stat table |
| 1.3.6.1.4.1.20044.107.11.7.354.1.2 | Columnpm100gemuxsfpPerfTelecomBerLinePreFecCurrent24StatInvBerPortn | read-only | current | Current 24-hours BER counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.354.1.3 | Columnpm100gemuxsfpPerfTelecomBerLinePreFecCurrent24StatBerValuePortn | read-only | current | Current 24-hours BER counter :This OID gives the current 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.107.11.7.354.1.4 | Columnpm100gemuxsfpPerfTelecomBerLinePreFecCurrent24StatInvMinBerPortn | read-only | current | Current 24-hoursMinBER counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.354.1.5 | Columnpm100gemuxsfpPerfTelecomBerLinePreFecCurrent24StatMinBerValuePortn | read-only | current | Current 24-hours MinBER counter :This OID gives the current 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.107.11.7.354.1.6 | Columnpm100gemuxsfpPerfTelecomBerLinePreFecCurrent24StatInvMaxBerPortn | read-only | current | Current 24-hours MaxBER counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.354.1.7 | Columnpm100gemuxsfpPerfTelecomBerLinePreFecCurrent24StatMaxBerValuePortn | read-only | current | Current 24-hours MaxBER counter :This OID gives the current 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.107.11.7.355 | Tablepm100gemuxsfpPerfTelecomBerLinePreFecPast24StatHistoryPort1Table | not-accessible | current | List of pm100gemuxsfpPerfTelecomBerLinePreFecPast24StatHistory Article |
| 1.3.6.1.4.1.20044.107.11.7.355.1 | Rowpm100gemuxsfpPerfTelecomBerLinePreFecPast24StatHistoryPort1Entry | not-accessible | current | Row definition for the pm100gemuxsfpPerfTelecomBerLinePreFecPast24StatHistory table |
| 1.3.6.1.4.1.20044.107.11.7.355.1.1 | Columnpm100gemuxsfpPerfTelecomBerLinePreFecPast24StatHistoryPort1Index | read-only | current | Index definition for the pm100gemuxsfpPerfTelecomBerLinePreFecPast24StatHistory table |
| 1.3.6.1.4.1.20044.107.11.7.355.1.2 | Columnpm100gemuxsfpPerfTelecomBerLinePreFecPast24StatHistoryInvBerPort1 | read-only | current | Previous 24-hours BER counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.355.1.3 | Columnpm100gemuxsfpPerfTelecomBerLinePreFecPast24StatHistoryBerValuePort1 | read-only | current | Previous 24-hours BER counter :This OID gives the previous 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.107.11.7.355.1.4 | Columnpm100gemuxsfpPerfTelecomBerLinePreFecPast24StatHistoryInvMinBerPort1 | read-only | current | Previous 24-hours MinBER counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.355.1.5 | Columnpm100gemuxsfpPerfTelecomBerLinePreFecPast24StatHistoryMinBerValuePort1 | read-only | current | Previous 24-hours MinBER counter :This OID gives the previous 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.107.11.7.355.1.6 | Columnpm100gemuxsfpPerfTelecomBerLinePreFecPast24StatHistoryInvMaxBerPort1 | read-only | current | Previous 24-hours MaxBER counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.107.11.7.355.1.7 | Columnpm100gemuxsfpPerfTelecomBerLinePreFecPast24StatHistoryMaxBerValuePort1 | read-only | current | Previous 24-hours MaxBER counter :This OID gives the previous 24-hours severely Errored Second counter value |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| Pm100gemuxsfpModuleMode | INTEGER { modulemode2x40g(1), modulemode1x40g4x10g(2), modulemode10x10g(3) } | current | Different values on the module mode |