EKINOPS-Pm100gfmuxd-MIB

730 objects
Creation
OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.111IdentitymodulePm100gfmuxdCreation
1.3.6.1.4.1.20044.111.2Nodepm100gfmuxdalarms
1.3.6.1.4.1.20044.111.2.1Nodepm100gfmuxdAlmOther
1.3.6.1.4.1.20044.111.2.1.1Nodepm100gfmuxdAlmOtherNurg
1.3.6.1.4.1.20044.111.2.1.1.2Nodepm100gfmuxdAlmsynthAlm2
1.3.6.1.4.1.20044.111.2.1.1.2.1Scalarpm100gfmuxdAlmConfTableSaveread-onlycurrentPM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> infor…
1.3.6.1.4.1.20044.111.2.1.1.2.2Scalarpm100gfmuxdAlmInvUploadread-onlycurrentInventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> informationalStatus(1000) <Alarmtype> ot…
1.3.6.1.4.1.20044.111.2.1.1.2.3Scalarpm100gfmuxdAlmConfTableLoadread-onlycurrentPM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> informationalStat…
1.3.6.1.4.1.20044.111.2.1.1.2.4Scalarpm100gfmuxdAlmCorrelatOffread-onlycurrentNot Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> informationalStatus(1000) <Alarmtype…
1.3.6.1.4.1.20044.111.2.1.1.2.5Scalarpm100gfmuxdAlmMaintenanceOnread-onlycurrentMaintenance Mode :This OID indicates that the RM is in maintenance mode. <Help> This alarm indicates that the maintenance mode is enabled on the PM <Condtype> …
1.3.6.1.4.1.20044.111.2.1.2Nodepm100gfmuxdAlmOtherUrg
1.3.6.1.4.1.20044.111.2.1.3Nodepm100gfmuxdAlmOtherCrit
1.3.6.1.4.1.20044.111.2.1.3.0Nodepm100gfmuxdAlmsynthAlm0
1.3.6.1.4.1.20044.111.2.1.3.0.2Scalarpm100gfmuxdAlmFailFanread-onlycurrentFan Fail :This OID is at 1 when any fail occurs on the fan tray <Help> This alarm indicates that the Fan tray module is in a failure condition <Condtype> FAIL_…
1.3.6.1.4.1.20044.111.2.1.3.0.9Scalarpm100gfmuxdAlmModGlobFailread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the RM <Help> This alarm is set on detection of a failure originating from the equip…
1.3.6.1.4.1.20044.111.2.1.3.0.15Scalarpm100gfmuxdAlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.111.2.1.3.0.16Scalarpm100gfmuxdAlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.111.2.2Nodepm100gfmuxdAlmClient
1.3.6.1.4.1.20044.111.2.2.1Nodepm100gfmuxdAlmClientNurg
1.3.6.1.4.1.20044.111.2.2.1.272Tablepm100gfmuxdAlmclientSfpWarnDdmTablenot-accessiblecurrentList of pm100gfmuxdAlmclientSfpWarnDdm Article
1.3.6.1.4.1.20044.111.2.2.1.272.1Rowpm100gfmuxdAlmclientSfpWarnDdmEntrynot-accessiblecurrentRow definition for the pm100gfmuxdAlmclientSfpWarnDdm table
1.3.6.1.4.1.20044.111.2.2.1.272.1.1Columnpm100gfmuxdAlmclientSfpWarnDdmIndexread-onlycurrentIndex definition for the pm100gfmuxdAlmclientSfpWarnDdm table
1.3.6.1.4.1.20044.111.2.2.1.272.1.2Columnpm100gfmuxdAlmTxPwLowWngPortnread-onlycurrentClient Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.111.2.2.1.272.1.3Columnpm100gfmuxdAlmTxPwrHighWngPortnread-onlycurrentClient Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.111.2.2.1.272.1.4Columnpm100gfmuxdAlmTxBiasLowWngPortnread-onlycurrentClient Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.111.2.2.1.272.1.5Columnpm100gfmuxdAlmTxBiasHighWngPortnread-onlycurrentClient Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warn…
1.3.6.1.4.1.20044.111.2.2.1.272.1.6Columnpm100gfmuxdAlmVccLowWngPortnread-onlycurrentClient Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Warn…
1.3.6.1.4.1.20044.111.2.2.1.272.1.7Columnpm100gfmuxdAlmVccHighWngPortnread-onlycurrentClient Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Wa…
1.3.6.1.4.1.20044.111.2.2.1.272.1.8Columnpm100gfmuxdAlmTempLowWngPortnread-onlycurrentClient Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indic…
1.3.6.1.4.1.20044.111.2.2.1.272.1.9Columnpm100gfmuxdAlmTempHighWngPortnread-onlycurrentClient Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning ind…
1.3.6.1.4.1.20044.111.2.2.1.272.1.16Columnpm100gfmuxdAlmRxPwrLowWngPortnread-onlycurrentClient Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning i…
1.3.6.1.4.1.20044.111.2.2.1.272.1.17Columnpm100gfmuxdAlmRxPwrHighWngPortnread-onlycurrentClient Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning…
1.3.6.1.4.1.20044.111.2.2.2Nodepm100gfmuxdAlmClientUrg
1.3.6.1.4.1.20044.111.2.2.2.152Tablepm100gfmuxdAlmclientHostLaneFaultTablenot-accessiblecurrentList of pm100gfmuxdAlmclientHostLaneFault Article
1.3.6.1.4.1.20044.111.2.2.2.152.1Rowpm100gfmuxdAlmclientHostLaneFaultEntrynot-accessiblecurrentRow definition for the pm100gfmuxdAlmclientHostLaneFault table
1.3.6.1.4.1.20044.111.2.2.2.152.1.1Columnpm100gfmuxdAlmclientHostLaneFaultIndexread-onlycurrentIndex definition for the pm100gfmuxdAlmclientHostLaneFault table
1.3.6.1.4.1.20044.111.2.2.2.152.1.2Columnpm100gfmuxdAlmClientLossOfSyncPortnread-onlycurrentClient Frame Alignment Loss :This OID indicates the module is not aligned with the incoming Client signal <Help> Alarm indicating the module is not aligned wit…
1.3.6.1.4.1.20044.111.2.2.2.152.1.3Columnpm100gfmuxdAlmClientInputLossOfSigPortnread-onlycurrentClient Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Client Trscv <Help> Alarm indicating a Loss of Signal is detected on the Cl…
1.3.6.1.4.1.20044.111.2.2.2.152.1.4Columnpm100gfmuxdAlmClientLanesMarkerUnlockPortnread-onlycurrentClient Lanes Marker Unlock :This OID indicates the Client lanes marker alignment is not lock <Help> Alarm indicating the Client lanes marker alignment is not l…
1.3.6.1.4.1.20044.111.2.2.2.152.1.5Columnpm100gfmuxdAlmClientLanes6466UnlockPortnread-onlycurrentClient Lanes 64/66b Unlock :This OID indicates the Client 64/66b decoder is not lock <Help> Alarm indicating the Client 64/66b decoder is not lock <Condtype> C…
1.3.6.1.4.1.20044.111.2.2.2.152.1.6Columnpm100gfmuxdAlmClientLanesNotAlignedPortnread-onlycurrentClient Lanes Not Aligned :This OID indicates the Client lanes are not aligned <Help> Alarm indicating the Client lanes are not aligned <Condtype> CLIENT_LANES_…
1.3.6.1.4.1.20044.111.2.2.2.152.1.7Columnpm100gfmuxdAlmClientCsfDetectedPortnread-onlycurrentClient Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client…
1.3.6.1.4.1.20044.111.2.2.2.152.1.10Columnpm100gfmuxdAlmClientTxHostLolPortnread-onlycurrentClient Host Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Client Trscv Host Lane <Help> Alarm indicating a Tx Loss of Lock on the Client Tr…
1.3.6.1.4.1.20044.111.2.2.2.152.1.11Columnpm100gfmuxdAlmClientLaneTxFifoErrorPortnread-onlycurrentClient Host Lane Tx FIFO Error :This OID indicates a Tx FIFO Error on the Client Trscv Host Lane <Help> Alarm indicating a Tx FIFO Error on the Client Trscv Ho…
1.3.6.1.4.1.20044.111.2.2.2.240Tablepm100gfmuxdAlmclientSfpAlmDdmTablenot-accessiblecurrentList of pm100gfmuxdAlmclientSfpAlmDdm Article
1.3.6.1.4.1.20044.111.2.2.2.240.1Rowpm100gfmuxdAlmclientSfpAlmDdmEntrynot-accessiblecurrentRow definition for the pm100gfmuxdAlmclientSfpAlmDdm table
1.3.6.1.4.1.20044.111.2.2.2.240.1.1Columnpm100gfmuxdAlmclientSfpAlmDdmIndexread-onlycurrentIndex definition for the pm100gfmuxdAlmclientSfpAlmDdm table
1.3.6.1.4.1.20044.111.2.2.2.240.1.2Columnpm100gfmuxdAlmTxPwrLowAlaPortnread-onlycurrentClient Trscv Tx Power Low :This OID indicates that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in…
1.3.6.1.4.1.20044.111.2.2.2.240.1.3Columnpm100gfmuxdAlmTxPwrHighAlaPortnread-onlycurrentClient Trscv Tx Power High :This OID indicates that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.111.2.2.2.240.1.4Columnpm100gfmuxdAlmTxBiasLowAlaPortnread-onlycurrentClient Trscv Bias Low :This OID indicates that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.111.2.2.2.240.1.5Columnpm100gfmuxdAlmTxBiasHighAlaPortnread-onlycurrentClient Trscv Bias High :This OID indicates that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM <Help> Alar…
1.3.6.1.4.1.20044.111.2.2.2.240.1.6Columnpm100gfmuxdAlmVccLowAlaPortnread-onlycurrentClient Trscv Power Supply Low :This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM <Help> Alar…
1.3.6.1.4.1.20044.111.2.2.2.240.1.7Columnpm100gfmuxdAlmVccHighAlaPortnread-onlycurrentClient Trscv Power Supply High :This OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM <Help> Al…
1.3.6.1.4.1.20044.111.2.2.2.240.1.8Columnpm100gfmuxdAlmTempLowAlaPortnread-onlycurrentClient Trscv Temp Low :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicat…
1.3.6.1.4.1.20044.111.2.2.2.240.1.9Columnpm100gfmuxdAlmTempHighAlaPortnread-onlycurrentClient Trscv Temp High :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indic…
1.3.6.1.4.1.20044.111.2.2.2.240.1.16Columnpm100gfmuxdAlmRxPwrLowAlaPortnread-onlycurrentClient Trscv Rx Power Low :This OID indicates that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm ind…
1.3.6.1.4.1.20044.111.2.2.2.240.1.17Columnpm100gfmuxdAlmRxPwrHighAlaPortnread-onlycurrentClient Trscv Rx Power High :This OID indicates that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm i…
1.3.6.1.4.1.20044.111.2.2.3Nodepm100gfmuxdAlmClientCrit
1.3.6.1.4.1.20044.111.2.2.3.8Tablepm100gfmuxdAlmsynthAlmPortTablenot-accessiblecurrentList of pm100gfmuxdAlmsynthAlmPort Article
1.3.6.1.4.1.20044.111.2.2.3.8.1Rowpm100gfmuxdAlmsynthAlmPortEntrynot-accessiblecurrentRow definition for the pm100gfmuxdAlmsynthAlmPort table
1.3.6.1.4.1.20044.111.2.2.3.8.1.1Columnpm100gfmuxdAlmsynthAlmPortIndexread-onlycurrentIndex definition for the pm100gfmuxdAlmsynthAlmPort table
1.3.6.1.4.1.20044.111.2.2.3.8.1.2Columnpm100gfmuxdAlmSfpAbsentPortnread-onlycurrentClient Optical Module Absent :This OID indicates that the Transceiver is not present in the client port. <Help> This alarm indicates if the client transceiver …
1.3.6.1.4.1.20044.111.2.2.3.8.1.3Columnpm100gfmuxdAlmDdmAbsentPortnread-onlycurrentDDM Supported On Client Trscv :This OID indicates that the Client transceiver supports the Digital Diagnostic Monitoring function <Help> This status indicates …
1.3.6.1.4.1.20044.111.2.2.3.8.1.5Columnpm100gfmuxdAlmHwFailAccPortnread-onlycurrentClient HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Help> This alarm indicates a failure on client port, most pro…
1.3.6.1.4.1.20044.111.2.2.3.8.1.6Columnpm100gfmuxdAlmDwLsdPortnread-onlycurrentClient Trscv Laser Shutdown :This OID indicates the Client transceiver laser is shutdown <Help> This status indicates if the client transceiver laser is shutdo…
1.3.6.1.4.1.20044.111.2.2.3.8.1.7Columnpm100gfmuxdAlmClientLocalOosPortnread-onlycurrentLocal Client Port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local c…
1.3.6.1.4.1.20044.111.2.2.3.8.1.8Columnpm100gfmuxdAlmClientRemoteOosPortnread-onlycurrentRemote Client Port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the remot…
1.3.6.1.4.1.20044.111.2.2.3.8.1.9Columnpm100gfmuxdAlmDwCaisPortnread-onlycurrentClient AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indicates if a Client Alarm Indication Signal is…
1.3.6.1.4.1.20044.111.2.2.3.8.1.10Columnpm100gfmuxdAlmSfpDdmWarningPortnread-onlycurrentWarning On Client Trscv DDM :This OID indicates a warning is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Warning has be…
1.3.6.1.4.1.20044.111.2.2.3.8.1.11Columnpm100gfmuxdAlmSfpDdmAlmPortnread-onlycurrentAlarm On Client Trscv DDM :This OID indicates an alarm is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Alarm has been de…
1.3.6.1.4.1.20044.111.2.2.3.8.1.13Columnpm100gfmuxdAlmFailAccPortnread-onlycurrentClient Access Fail :This OID indicates a failure on the Client port <Help> This alarm indicates a failure on the Client port <Condtype> FAIL_ACC_1 <Probcause> …
1.3.6.1.4.1.20044.111.2.2.3.8.1.14Columnpm100gfmuxdAlmClientLoopbackOnPortnread-onlycurrentClient Loopback Enabled :This OID indicates a loopback is enabled on the port <Help> This alarm indicates a loopback is enabled on the port <Condtype> CLIENT_L…
1.3.6.1.4.1.20044.111.2.2.3.8.1.17Columnpm100gfmuxdAlmUpCsfPortnread-onlycurrentClient Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu…
1.3.6.1.4.1.20044.111.2.3Nodepm100gfmuxdAlmLine
1.3.6.1.4.1.20044.111.2.3.1Nodepm100gfmuxdAlmLineNurg
1.3.6.1.4.1.20044.111.2.3.1.104Tablepm100gfmuxdAlmlineQsfpWarnDdmTablenot-accessiblecurrentList of pm100gfmuxdAlmlineQsfpWarnDdm Article
1.3.6.1.4.1.20044.111.2.3.1.104.1Rowpm100gfmuxdAlmlineQsfpWarnDdmEntrynot-accessiblecurrentRow definition for the pm100gfmuxdAlmlineQsfpWarnDdm table
1.3.6.1.4.1.20044.111.2.3.1.104.1.1Columnpm100gfmuxdAlmlineQsfpWarnDdmIndexread-onlycurrentIndex definition for the pm100gfmuxdAlmlineQsfpWarnDdm table
1.3.6.1.4.1.20044.111.2.3.1.104.1.2Columnpm100gfmuxdAlmLineTxPwLowWngPortnread-onlycurrentLine Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning in…
1.3.6.1.4.1.20044.111.2.3.1.104.1.3Columnpm100gfmuxdAlmLineTxPwrHighWngPortnread-onlycurrentLine Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.111.2.3.1.104.1.4Columnpm100gfmuxdAlmLineTxBiasLowWngPortnread-onlycurrentLine Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.111.2.3.1.104.1.5Columnpm100gfmuxdAlmLineTxBiasHighWngPortnread-onlycurrentLine Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.111.2.3.1.104.1.6Columnpm100gfmuxdAlmLineVccLowWngPortnread-onlycurrentLine Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.111.2.3.1.104.1.7Columnpm100gfmuxdAlmLineVccHighWngPortnread-onlycurrentLine Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Warn…
1.3.6.1.4.1.20044.111.2.3.1.104.1.8Columnpm100gfmuxdAlmLineTempLowWngPortnread-onlycurrentLine Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indicat…
1.3.6.1.4.1.20044.111.2.3.1.104.1.9Columnpm100gfmuxdAlmLineTempHighWngPortnread-onlycurrentLine Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning indic…
1.3.6.1.4.1.20044.111.2.3.1.104.1.16Columnpm100gfmuxdAlmLineRxPwrLowWngPortnread-onlycurrentLine Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning ind…
1.3.6.1.4.1.20044.111.2.3.1.104.1.17Columnpm100gfmuxdAlmLineRxPwrHighWngPortnread-onlycurrentLine Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning i…
1.3.6.1.4.1.20044.111.2.3.1.184Tablepm100gfmuxdAlmlineNetworkLaneAlarmWarning1Tablenot-accessiblecurrentList of pm100gfmuxdAlmlineNetworkLaneAlarmWarning1 Article
1.3.6.1.4.1.20044.111.2.3.1.184.1Rowpm100gfmuxdAlmlineNetworkLaneAlarmWarning1Entrynot-accessiblecurrentRow definition for the pm100gfmuxdAlmlineNetworkLaneAlarmWarning1 table
1.3.6.1.4.1.20044.111.2.3.1.184.1.1Columnpm100gfmuxdAlmlineNetworkLaneAlarmWarning1Indexread-onlycurrentIndex definition for the pm100gfmuxdAlmlineNetworkLaneAlarmWarning1 table
1.3.6.1.4.1.20044.111.2.3.1.184.1.2Columnpm100gfmuxdAlmLineRxPowerLowAlarmPortnread-onlycurrentLine Trscv Rx Power Low Alarm :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicat…
1.3.6.1.4.1.20044.111.2.3.1.184.1.3Columnpm100gfmuxdAlmLineRxPowerLowWarningPortnread-onlycurrentLine Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning ind…
1.3.6.1.4.1.20044.111.2.3.1.184.1.4Columnpm100gfmuxdAlmLineRxPowerHighWarningPortnread-onlycurrentLine Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning i…
1.3.6.1.4.1.20044.111.2.3.1.184.1.5Columnpm100gfmuxdAlmLineRxPowerHighAlarmPortnread-onlycurrentLine Trscv Rx Power High Alarm :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indic…
1.3.6.1.4.1.20044.111.2.3.1.184.1.6Columnpm100gfmuxdAlmLineLaserTempLowAlarmPortnread-onlycurrentLine Trscv Tx Laser Temp Low Alarm :This OID indicates that the Trscv Tx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help>…
1.3.6.1.4.1.20044.111.2.3.1.184.1.7Columnpm100gfmuxdAlmLineLaserTempLowWarningPortnread-onlycurrentLine Trscv Tx Laser Temp Low Warning :This OID indicates that the Trscv Tx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Hel…
1.3.6.1.4.1.20044.111.2.3.1.184.1.8Columnpm100gfmuxdAlmLineLaserTempHighWarningPortnread-onlycurrentLine Trscv Tx Laser Temp High Warning :This OID indicates that the Trscv Tx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <H…
1.3.6.1.4.1.20044.111.2.3.1.184.1.9Columnpm100gfmuxdAlmLineLaserTempHighAlarmPortnread-onlycurrentLine Trscv Tx Laser Temp High Alarm :This OID indicates that the Trscv Tx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Hel…
1.3.6.1.4.1.20044.111.2.3.1.184.1.10Columnpm100gfmuxdAlmLineTxPowerLowAlarmPortnread-onlycurrentLine Trscv Tx Power Low Alarm :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indica…
1.3.6.1.4.1.20044.111.2.3.1.184.1.11Columnpm100gfmuxdAlmLineTxPowerLowWarningPortnread-onlycurrentLine Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning in…
1.3.6.1.4.1.20044.111.2.3.1.184.1.12Columnpm100gfmuxdAlmLineTxPowerHighWarningPortnread-onlycurrentLine Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.111.2.3.1.184.1.13Columnpm100gfmuxdAlmLineTxPowerHighAlarmPortnread-onlycurrentLine Trscv Tx Power High Alarm :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indi…
1.3.6.1.4.1.20044.111.2.3.1.184.1.14Columnpm100gfmuxdAlmLineBiasLowAlarmPortnread-onlycurrentLine Trscv Tx Bias Low Alarm :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alarm i…
1.3.6.1.4.1.20044.111.2.3.1.184.1.15Columnpm100gfmuxdAlmLineBiasLowWarningPortnread-onlycurrentLine Trscv Tx Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warni…
1.3.6.1.4.1.20044.111.2.3.1.184.1.16Columnpm100gfmuxdAlmLineBiasHighWarningPortnread-onlycurrentLine Trscv Tx Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> War…
1.3.6.1.4.1.20044.111.2.3.1.184.1.17Columnpm100gfmuxdAlmLineBiasHighAlarmPortnread-onlycurrentLine Trscv Tx Bias High Alarm :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Alarm…
1.3.6.1.4.1.20044.111.2.3.1.188Tablepm100gfmuxdAlmlineNetworkLaneAlarmWarning2Tablenot-accessiblecurrentList of pm100gfmuxdAlmlineNetworkLaneAlarmWarning2 Article
1.3.6.1.4.1.20044.111.2.3.1.188.1Rowpm100gfmuxdAlmlineNetworkLaneAlarmWarning2Entrynot-accessiblecurrentRow definition for the pm100gfmuxdAlmlineNetworkLaneAlarmWarning2 table
1.3.6.1.4.1.20044.111.2.3.1.188.1.1Columnpm100gfmuxdAlmlineNetworkLaneAlarmWarning2Indexread-onlycurrentIndex definition for the pm100gfmuxdAlmlineNetworkLaneAlarmWarning2 table
1.3.6.1.4.1.20044.111.2.3.1.188.1.2Columnpm100gfmuxdAlmTxModulatorBiasLowAlarmPortnread-onlycurrentLine Trscv Tx Modulator Bias Low Alarm :This OID indicates that the Trscv Tx modulator bias current is lower than the threshold value written in the Trscv EEPR…
1.3.6.1.4.1.20044.111.2.3.1.188.1.3Columnpm100gfmuxdAlmTxModulatorBiasLowWarningPortnread-onlycurrentLine Trscv Tx Modulator Bias Low Warning :This OID indicates that the Trscv Tx modulator bias current is lower than the threshold value written in the Trscv EE…
1.3.6.1.4.1.20044.111.2.3.1.188.1.4Columnpm100gfmuxdAlmTxModulatorBiasHighWarningPortnread-onlycurrentLine Trscv Tx Modulator Bias High Warning :This OID indicates that the Trscv Tx modulator bias current is higher than the threshold value written in the Trscv …
1.3.6.1.4.1.20044.111.2.3.1.188.1.5Columnpm100gfmuxdAlmTxModulatorBiasHighAlarmPortnread-onlycurrentLine Trscv Tx Modulator Bias High Alarm :This OID indicates that the Trscv Tx modulator bias current is higher than the threshold value written in the Trscv EE…
1.3.6.1.4.1.20044.111.2.3.1.188.1.6Columnpm100gfmuxdAlmRxLaserTempLowAlarmPortnread-onlycurrentLine Trscv Rx Laser Temp Low Alarm :This OID indicates that the Trscv Rx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help>…
1.3.6.1.4.1.20044.111.2.3.1.188.1.7Columnpm100gfmuxdAlmRxLaserTempLowWarningPortnread-onlycurrentLine Trscv Rx Laser Temp Low Warning :This OID indicates that the Trscv Rx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Hel…
1.3.6.1.4.1.20044.111.2.3.1.188.1.8Columnpm100gfmuxdAlmRxLaserTempHighWarningPortnread-onlycurrentLine Trscv Rx Laser Temp High Warning :This OID indicates that the Trscv Rx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <H…
1.3.6.1.4.1.20044.111.2.3.1.188.1.9Columnpm100gfmuxdAlmRxLaserTempHighAlarmPortnread-onlycurrentLine Trscv Rx Laser Temp High Alarm :This OID indicates that the Trscv Rx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Hel…
1.3.6.1.4.1.20044.111.2.3.1.188.1.10Columnpm100gfmuxdAlmRxLaserOutputLowAlarmPortnread-onlycurrentLine Trscv Rx Output Power Low Alarm :This OID indicates that the Trscv Rx output power is lower than the threshold value written in the Trscv EEPROM <Help> Al…
1.3.6.1.4.1.20044.111.2.3.1.188.1.11Columnpm100gfmuxdAlmRxLaserOutputLowWarningPortnread-onlycurrentLine Trscv Rx Output Power Low Warning :This OID indicates that the Trscv Rx output power is lower than the threshold value written in the Trscv EEPROM <Help> …
1.3.6.1.4.1.20044.111.2.3.1.188.1.12Columnpm100gfmuxdAlmRxLaserOutputHighWarningPortnread-onlycurrentLine Trscv Rx Output Power High Warning :This OID indicates that the Trscv Rx output power is higher than the threshold value written in the Trscv EEPROM <Help…
1.3.6.1.4.1.20044.111.2.3.1.188.1.13Columnpm100gfmuxdAlmRxLaserOutputHighAlarmPortnread-onlycurrentLine Trscv Rx Output Power High Alarm :This OID indicates that the Trscv Rx output power is higher than the threshold value written in the Trscv EEPROM <Help> …
1.3.6.1.4.1.20044.111.2.3.1.188.1.14Columnpm100gfmuxdAlmRxLaserBiasLowAlarmPortnread-onlycurrentLine Trscv Rx Bias Low Alarm :This OID indicates that the Trscv Rx laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alar…
1.3.6.1.4.1.20044.111.2.3.1.188.1.15Columnpm100gfmuxdAlmRxLaserBiasLowWarningPortnread-onlycurrentLine Trscv Rx Bias Low Warning :This OID indicates that the Trscv Rx laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Wa…
1.3.6.1.4.1.20044.111.2.3.1.188.1.16Columnpm100gfmuxdAlmRxLaserBiasHighWarningPortnread-onlycurrentLine Trscv Rx Bias High Warning :This OID indicates that the Trscv Rx laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> …
1.3.6.1.4.1.20044.111.2.3.1.188.1.17Columnpm100gfmuxdAlmRxLaserBiasHighAlarmPortnread-onlycurrentLine Trscv Rx Bias High Alarm :This OID indicates that the Trscv Rx laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Al…
1.3.6.1.4.1.20044.111.2.3.2Nodepm100gfmuxdAlmLineUrg
1.3.6.1.4.1.20044.111.2.3.2.72Tablepm100gfmuxdAlmlineQsfpAlmDdmTablenot-accessiblecurrentList of pm100gfmuxdAlmlineQsfpAlmDdm Article
1.3.6.1.4.1.20044.111.2.3.2.72.1Rowpm100gfmuxdAlmlineQsfpAlmDdmEntrynot-accessiblecurrentRow definition for the pm100gfmuxdAlmlineQsfpAlmDdm table
1.3.6.1.4.1.20044.111.2.3.2.72.1.1Columnpm100gfmuxdAlmlineQsfpAlmDdmIndexread-onlycurrentIndex definition for the pm100gfmuxdAlmlineQsfpAlmDdm table
1.3.6.1.4.1.20044.111.2.3.2.72.1.2Columnpm100gfmuxdAlmLineTxPwLowAlmPortnread-onlycurrentLine Trscv Tx Power Low Alarm :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indica…
1.3.6.1.4.1.20044.111.2.3.2.72.1.3Columnpm100gfmuxdAlmLineTxPwrHighAlmPortnread-onlycurrentLine Trscv Tx Power High Alarm :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indi…
1.3.6.1.4.1.20044.111.2.3.2.72.1.4Columnpm100gfmuxdAlmLineTxBiasLowAlmPortnread-onlycurrentLine Trscv Bias Low Alarm :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indi…
1.3.6.1.4.1.20044.111.2.3.2.72.1.5Columnpm100gfmuxdAlmLineTxBiasHighAlmPortnread-onlycurrentLine Trscv Bias High Alarm :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Alarm in…
1.3.6.1.4.1.20044.111.2.3.2.72.1.6Columnpm100gfmuxdAlmLineVccLowAlmPortnread-onlycurrentLine Trscv Power Supply Low Alarm :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in…
1.3.6.1.4.1.20044.111.2.3.2.72.1.7Columnpm100gfmuxdAlmLineVccHighAlmPortnread-onlycurrentLine Trscv Power Supply High Alarm :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.111.2.3.2.72.1.8Columnpm100gfmuxdAlmLineTempLowAlmPortnread-onlycurrentLine Trscv Temp Low Alarm :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicating …
1.3.6.1.4.1.20044.111.2.3.2.72.1.9Columnpm100gfmuxdAlmLineTempHighAlmPortnread-onlycurrentLine Trscv Temp High Alarm :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indicatin…
1.3.6.1.4.1.20044.111.2.3.2.72.1.16Columnpm100gfmuxdAlmLineRxPwrLowAlmPortnread-onlycurrentLine Trscv Rx Power Low Alarm :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicat…
1.3.6.1.4.1.20044.111.2.3.2.72.1.17Columnpm100gfmuxdAlmLineRxPwrHighAlmPortnread-onlycurrentLine Trscv Rx Power High Alarm :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indic…
1.3.6.1.4.1.20044.111.2.3.2.196Tablepm100gfmuxdAlmlineHostLaneFaultTablenot-accessiblecurrentList of pm100gfmuxdAlmlineHostLaneFault Article
1.3.6.1.4.1.20044.111.2.3.2.196.1Rowpm100gfmuxdAlmlineHostLaneFaultEntrynot-accessiblecurrentRow definition for the pm100gfmuxdAlmlineHostLaneFault table
1.3.6.1.4.1.20044.111.2.3.2.196.1.1Columnpm100gfmuxdAlmlineHostLaneFaultIndexread-onlycurrentIndex definition for the pm100gfmuxdAlmlineHostLaneFault table
1.3.6.1.4.1.20044.111.2.3.2.196.1.2Columnpm100gfmuxdAlmLineInputLossOfSignalPortnread-onlycurrentLine Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Line Trscv <Help> Alarm indicating a Loss of Signal is detected on the Line T…
1.3.6.1.4.1.20044.111.2.3.2.196.1.3Columnpm100gfmuxdAlmLineLossOfFramePortnread-onlycurrentLine Loss Of Frame :This OID indicates the module is not aligned with the incoming Line signal <Help> Alarm indicating the module is not aligned with the incom…
1.3.6.1.4.1.20044.111.2.3.2.196.1.4Columnpm100gfmuxdAlmLineSmBdiInsertedPortnread-onlycurrentLine SM BDI Inserted :This OID indicates a SM Backward Defect Indication is inserted on the outgoing Line signal <Help> Status indicating a SM Backward Defect …
1.3.6.1.4.1.20044.111.2.3.2.196.1.5Columnpm100gfmuxdAlmLineSmBdiDetectedPortnread-onlycurrentLine SM BDI Detected :This OID indicates a SM Backward Defect Indication is detected on the incoming Line signal <Help> Alarm indicating a SM Backward Defect I…
1.3.6.1.4.1.20044.111.2.3.2.196.1.6Columnpm100gfmuxdAlmLineSmIaeInsertedPortnread-onlycurrentLine SM IAE Inserted :This OID indicates a SM Incoming Alignment Error is inserted on the outgoing Line signal <Help> Status indicating a SM Incoming Alignment…
1.3.6.1.4.1.20044.111.2.3.2.196.1.7Columnpm100gfmuxdAlmLineSmIaeDetectedPortnread-onlycurrentLine SM IAE Detected :This OID indicates a SM Incoming Alignment Error is detected on the incoming Line signal <Help> Alarm indicating a SM Incoming Alignment …
1.3.6.1.4.1.20044.111.2.3.2.196.1.10Columnpm100gfmuxdAlmLineEncryptionFailurePortnread-onlycurrentEncryption Failure :This OID indicates the encryption mechanism failed, impacting the traffic (the line traffic is down). <Help> This alarm indicates the encry…
1.3.6.1.4.1.20044.111.2.3.3Nodepm100gfmuxdAlmLineCrit
1.3.6.1.4.1.20044.111.2.3.3.40Tablepm100gfmuxdAlmsynthAlmLineTablenot-accessiblecurrentList of pm100gfmuxdAlmsynthAlmLine Article
1.3.6.1.4.1.20044.111.2.3.3.40.1Rowpm100gfmuxdAlmsynthAlmLineEntrynot-accessiblecurrentRow definition for the pm100gfmuxdAlmsynthAlmLine table
1.3.6.1.4.1.20044.111.2.3.3.40.1.1Columnpm100gfmuxdAlmsynthAlmLineIndexread-onlycurrentIndex definition for the pm100gfmuxdAlmsynthAlmLine table
1.3.6.1.4.1.20044.111.2.3.3.40.1.2Columnpm100gfmuxdAlmXfpAbsentPortnread-onlycurrentLine Optical Module Absent :This OID indicates that the line optical interface is not present. <Help> This alarm indicates if the line transceiver is not plugg…
1.3.6.1.4.1.20044.111.2.3.3.40.1.3Columnpm100gfmuxdAlmXfpInitNotComplPortnread-onlycurrentLine Optical Module Ready :This OID indicates that the optical interface is not operational. <Help> This status indicates if the line transceiver has been corr…
1.3.6.1.4.1.20044.111.2.3.3.40.1.5Columnpm100gfmuxdAlmLineHwFailPortnread-onlycurrentLine Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Help> This alarm indicates a failure on line port, most pr…
1.3.6.1.4.1.20044.111.2.3.3.40.1.6Columnpm100gfmuxdAlmXfpTxOffPortnread-onlycurrentLine Trscv Laser Shutdown :This OID indicates the Line transceiver laser is shutdown <Help> This status indicates if the Line transceiver laser is shutdown <Co…
1.3.6.1.4.1.20044.111.2.3.3.40.1.7Columnpm100gfmuxdAlmLineLocalOosPortnread-onlycurrentLine Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service…
1.3.6.1.4.1.20044.111.2.3.3.40.1.9Columnpm100gfmuxdAlmUpRdiInsPortnread-onlycurrentMS-RDI/L-RDI Inserted On Line :This OID indicates an upstream MS-RDI/L-RDI has been inserted in the outgoing 10 Gb/s SDH/SONET signal. <Help> This status indic…
1.3.6.1.4.1.20044.111.2.3.3.40.1.10Columnpm100gfmuxdAlmLineDdmWarningPortnread-onlycurrentWarning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Warning has…
1.3.6.1.4.1.20044.111.2.3.3.40.1.11Columnpm100gfmuxdAlmLineDdmAlmPortnread-onlycurrentAlarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Alarm has been…
1.3.6.1.4.1.20044.111.2.3.3.40.1.13Columnpm100gfmuxdAlmLineFailPortnread-onlycurrentLine Port Failure :This OID indicates a failure on the line port <Help> This alarm indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipm…
1.3.6.1.4.1.20044.111.2.3.3.40.1.14Columnpm100gfmuxdAlmLineLoopbackOnPortnread-onlycurrentLine Loopback Enabled :This OID indicates a loopback is enabled on the port <Help> This alarm indicates a loopback is enabled on the port <Condtype> LINE_LOOPB…
1.3.6.1.4.1.20044.111.2.3.3.40.1.17Columnpm100gfmuxdAlmLineActivePortnread-onlycurrentLine Active :This OID indicates whether the line is active or standby. <Help> This status indicates whether the line is active or standby. <Condtype> LINE_ACTI…
1.3.6.1.4.1.20044.111.3Nodepm100gfmuxdmeasures
1.3.6.1.4.1.20044.111.3.1Nodepm100gfmuxdMesrOther
1.3.6.1.4.1.20044.111.3.1.400Scalarpm100gfmuxdMesrlineTrscv1Tempread-onlycurrentLine Trscv Q4 Temperature :This OID gives the temperature value of the Transceiver Q4, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV_S16/…
1.3.6.1.4.1.20044.111.3.1.401Scalarpm100gfmuxdMesrlineTrscv2Tempread-onlycurrentLine Trscv Q3 Temperature :This OID gives the temperature value of the Transceiver Q3, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV_S16/…
1.3.6.1.4.1.20044.111.3.1.492Scalarpm100gfmuxdMesrlineTrscv1TempMinread-onlycurrentMin Line Trscv 3 Temperature :This OID gives the minimum temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperat…
1.3.6.1.4.1.20044.111.3.1.493Scalarpm100gfmuxdMesrlineTrscv2TempMinread-onlycurrentMin Line Trscv 4 Temperature :This OID gives the minimum temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperat…
1.3.6.1.4.1.20044.111.3.1.496Scalarpm100gfmuxdMesrlineTrscv1TempMaxread-onlycurrentMax Line Trscv 3 Temperature :This OID gives the maximum temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperat…
1.3.6.1.4.1.20044.111.3.1.497Scalarpm100gfmuxdMesrlineTrscv2TempMaxread-onlycurrentMax Line Trscv 4 Temperature :This OID gives the maximum temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperat…
1.3.6.1.4.1.20044.111.3.1.500Scalarpm100gfmuxdMesrmoduleTempMinread-onlycurrentMin Module Temperature :This OID gives the minimum temperature value of the Module (Temperature = AV_S16/256) (Unit = C) <Help> This Measure gives the minimum …
1.3.6.1.4.1.20044.111.3.1.501Scalarpm100gfmuxdMesrmoduleTempMaxread-onlycurrentMax Module Temperature :This OID gives the maximum temperature value of the Module (Temperature = AV_S16/256) (Unit = C) <Help> This Measure gives the maximum …
1.3.6.1.4.1.20044.111.3.2Nodepm100gfmuxdMesrClient
1.3.6.1.4.1.20044.111.3.2.16Tablepm100gfmuxdMesrclientTxTempTablenot-accessiblecurrentList of pm100gfmuxdMesrclientTxTemp Article
1.3.6.1.4.1.20044.111.3.2.16.1Rowpm100gfmuxdMesrclientTxTempEntrynot-accessiblecurrentRow definition for the pm100gfmuxdMesrclientTxTemp table
1.3.6.1.4.1.20044.111.3.2.16.1.1Columnpm100gfmuxdMesrclientTxTempIndexread-onlycurrentIndex definition for the pm100gfmuxdMesrclientTxTemp table
1.3.6.1.4.1.20044.111.3.2.16.1.2Columnpm100gfmuxdMesrclientTxTempPortnread-onlycurrentClient Trscv Temperature :This OID gives the Laser temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature …
1.3.6.1.4.1.20044.111.3.2.48Tablepm100gfmuxdMesrclientTxBiasTablenot-accessiblecurrentList of pm100gfmuxdMesrclientTxBias Article
1.3.6.1.4.1.20044.111.3.2.48.1Rowpm100gfmuxdMesrclientTxBiasEntrynot-accessiblecurrentRow definition for the pm100gfmuxdMesrclientTxBias table
1.3.6.1.4.1.20044.111.3.2.48.1.1Columnpm100gfmuxdMesrclientTxBiasIndexread-onlycurrentIndex definition for the pm100gfmuxdMesrclientTxBias table
1.3.6.1.4.1.20044.111.3.2.48.1.2Columnpm100gfmuxdMesrclientTxBiasPortnread-onlycurrentClient Trscv Laser Bias :This OID gives the Laser bias value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV_U16/500) (…
1.3.6.1.4.1.20044.111.3.2.80Tablepm100gfmuxdMesrclientTxPwrTablenot-accessiblecurrentList of pm100gfmuxdMesrclientTxPwr Article
1.3.6.1.4.1.20044.111.3.2.80.1Rowpm100gfmuxdMesrclientTxPwrEntrynot-accessiblecurrentRow definition for the pm100gfmuxdMesrclientTxPwr table
1.3.6.1.4.1.20044.111.3.2.80.1.1Columnpm100gfmuxdMesrclientTxPwrIndexread-onlycurrentIndex definition for the pm100gfmuxdMesrclientTxPwr table
1.3.6.1.4.1.20044.111.3.2.80.1.2Columnpm100gfmuxdMesrclientTxPwrPortnread-onlycurrentClient Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_…
1.3.6.1.4.1.20044.111.3.2.112Tablepm100gfmuxdMesrclientRxPwrTablenot-accessiblecurrentList of pm100gfmuxdMesrclientRxPwr Article
1.3.6.1.4.1.20044.111.3.2.112.1Rowpm100gfmuxdMesrclientRxPwrEntrynot-accessiblecurrentRow definition for the pm100gfmuxdMesrclientRxPwr table
1.3.6.1.4.1.20044.111.3.2.112.1.1Columnpm100gfmuxdMesrclientRxPwrIndexread-onlycurrentIndex definition for the pm100gfmuxdMesrclientRxPwr table
1.3.6.1.4.1.20044.111.3.2.112.1.2Columnpm100gfmuxdMesrclientRxPwrPortnread-onlycurrentClient Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16…
1.3.6.1.4.1.20044.111.3.2.416Tablepm100gfmuxdMesrclientTempMinTablenot-accessiblecurrentList of pm100gfmuxdMesrclientTempMin Article
1.3.6.1.4.1.20044.111.3.2.416.1Rowpm100gfmuxdMesrclientTempMinEntrynot-accessiblecurrentRow definition for the pm100gfmuxdMesrclientTempMin table
1.3.6.1.4.1.20044.111.3.2.416.1.1Columnpm100gfmuxdMesrclientTempMinIndexread-onlycurrentIndex definition for the pm100gfmuxdMesrclientTempMin table
1.3.6.1.4.1.20044.111.3.2.416.1.2Columnpm100gfmuxdMesrclientTempMinPortnread-onlycurrentMin Client Trscv Temperature :This OID gives the minimum temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temper…
1.3.6.1.4.1.20044.111.3.2.448Tablepm100gfmuxdMesrclientTempMaxTablenot-accessiblecurrentList of pm100gfmuxdMesrclientTempMax Article
1.3.6.1.4.1.20044.111.3.2.448.1Rowpm100gfmuxdMesrclientTempMaxEntrynot-accessiblecurrentRow definition for the pm100gfmuxdMesrclientTempMax table
1.3.6.1.4.1.20044.111.3.2.448.1.1Columnpm100gfmuxdMesrclientTempMaxIndexread-onlycurrentIndex definition for the pm100gfmuxdMesrclientTempMax table
1.3.6.1.4.1.20044.111.3.2.448.1.2Columnpm100gfmuxdMesrclientTempMaxPortnread-onlycurrentMax Client Trscv Temperature :This OID gives the maximum temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temper…
1.3.6.1.4.1.20044.111.3.3Nodepm100gfmuxdMesrLine
1.3.6.1.4.1.20044.111.3.3.144Tablepm100gfmuxdMesrlineTxPwrMinTablenot-accessiblecurrentList of pm100gfmuxdMesrlineTxPwrMin Article
1.3.6.1.4.1.20044.111.3.3.144.1Rowpm100gfmuxdMesrlineTxPwrMinEntrynot-accessiblecurrentRow definition for the pm100gfmuxdMesrlineTxPwrMin table
1.3.6.1.4.1.20044.111.3.3.144.1.1Columnpm100gfmuxdMesrlineTxPwrMinIndexread-onlycurrentIndex definition for the pm100gfmuxdMesrlineTxPwrMin table
1.3.6.1.4.1.20044.111.3.3.144.1.2Columnpm100gfmuxdMesrlineTxPwrMinPortnread-onlycurrentMin Line Trscv Tx Power :This OID gives the minimum transmit power value among the network lanes of the Line Transceiver, read from the DDM (Digital Diagnostic…
1.3.6.1.4.1.20044.111.3.3.160Tablepm100gfmuxdMesrlineTxCompositePwrTablenot-accessiblecurrentList of pm100gfmuxdMesrlineTxCompositePwr Article
1.3.6.1.4.1.20044.111.3.3.160.1Rowpm100gfmuxdMesrlineTxCompositePwrEntrynot-accessiblecurrentRow definition for the pm100gfmuxdMesrlineTxCompositePwr table
1.3.6.1.4.1.20044.111.3.3.160.1.1Columnpm100gfmuxdMesrlineTxCompositePwrIndexread-onlycurrentIndex definition for the pm100gfmuxdMesrlineTxCompositePwr table
1.3.6.1.4.1.20044.111.3.3.160.1.2Columnpm100gfmuxdMesrlineTxCompositePwrPortnread-onlycurrentLine Composite Tx Power (LR4/SR4) :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Line Transceiver, read from the…
1.3.6.1.4.1.20044.111.3.3.176Tablepm100gfmuxdMesrlineRxPwrMinTablenot-accessiblecurrentList of pm100gfmuxdMesrlineRxPwrMin Article
1.3.6.1.4.1.20044.111.3.3.176.1Rowpm100gfmuxdMesrlineRxPwrMinEntrynot-accessiblecurrentRow definition for the pm100gfmuxdMesrlineRxPwrMin table
1.3.6.1.4.1.20044.111.3.3.176.1.1Columnpm100gfmuxdMesrlineRxPwrMinIndexread-onlycurrentIndex definition for the pm100gfmuxdMesrlineRxPwrMin table
1.3.6.1.4.1.20044.111.3.3.176.1.2Columnpm100gfmuxdMesrlineRxPwrMinPortnread-onlycurrentMin Line Trscv Rx Power :This OID gives the minimum receive power value among the network lanes of the Line Transceiver, read from the DDM (Digital Diagnostic …
1.3.6.1.4.1.20044.111.3.3.192Tablepm100gfmuxdMesrlineRxCompositePwrTablenot-accessiblecurrentList of pm100gfmuxdMesrlineRxCompositePwr Article
1.3.6.1.4.1.20044.111.3.3.192.1Rowpm100gfmuxdMesrlineRxCompositePwrEntrynot-accessiblecurrentRow definition for the pm100gfmuxdMesrlineRxCompositePwr table
1.3.6.1.4.1.20044.111.3.3.192.1.1Columnpm100gfmuxdMesrlineRxCompositePwrIndexread-onlycurrentIndex definition for the pm100gfmuxdMesrlineRxCompositePwr table
1.3.6.1.4.1.20044.111.3.3.192.1.2Columnpm100gfmuxdMesrlineRxCompositePwrPortnread-onlycurrentLine Composite Rx Power (LR4/SR4) :This OID gives the composite receive power (sum of the network lanes receive power) of the Line Transceiver, read from the D…
1.3.6.1.4.1.20044.111.3.3.208Tablepm100gfmuxdMesrlineTxPwrMaxTablenot-accessiblecurrentList of pm100gfmuxdMesrlineTxPwrMax Article
1.3.6.1.4.1.20044.111.3.3.208.1Rowpm100gfmuxdMesrlineTxPwrMaxEntrynot-accessiblecurrentRow definition for the pm100gfmuxdMesrlineTxPwrMax table
1.3.6.1.4.1.20044.111.3.3.208.1.1Columnpm100gfmuxdMesrlineTxPwrMaxIndexread-onlycurrentIndex definition for the pm100gfmuxdMesrlineTxPwrMax table
1.3.6.1.4.1.20044.111.3.3.208.1.2Columnpm100gfmuxdMesrlineTxPwrMaxPortnread-onlycurrentMax Line Trscv Tx Power :This OID gives the maximum transmit power value among the network lanes of the Line Transceiver, read from the DDM (Digital Diagnostic…
1.3.6.1.4.1.20044.111.3.3.240Tablepm100gfmuxdMesrlineRxPwrMaxTablenot-accessiblecurrentList of pm100gfmuxdMesrlineRxPwrMax Article
1.3.6.1.4.1.20044.111.3.3.240.1Rowpm100gfmuxdMesrlineRxPwrMaxEntrynot-accessiblecurrentRow definition for the pm100gfmuxdMesrlineRxPwrMax table
1.3.6.1.4.1.20044.111.3.3.240.1.1Columnpm100gfmuxdMesrlineRxPwrMaxIndexread-onlycurrentIndex definition for the pm100gfmuxdMesrlineRxPwrMax table
1.3.6.1.4.1.20044.111.3.3.240.1.2Columnpm100gfmuxdMesrlineRxPwrMaxPortnread-onlycurrentMax Line Trscv Rx Power :This OID gives the maximum receive power value among the network lanes of the Line Transceiver, read in the DDM (Digital Diagnostic Mo…
1.3.6.1.4.1.20044.111.4Nodepm100gfmuxdcounters
1.3.6.1.4.1.20044.111.4.1Nodepm100gfmuxdCntOther
1.3.6.1.4.1.20044.111.4.2Nodepm100gfmuxdCntClient
1.3.6.1.4.1.20044.111.4.2.112Tablepm100gfmuxdCntclientInputErrorCounterTablenot-accessiblecurrentList of pm100gfmuxdCntclientInputErrorCounter Article
1.3.6.1.4.1.20044.111.4.2.112.1Rowpm100gfmuxdCntclientInputErrorCounterEntrynot-accessiblecurrentRow definition for the pm100gfmuxdCntclientInputErrorCounter table
1.3.6.1.4.1.20044.111.4.2.112.1.1Columnpm100gfmuxdCntclientInputErrorCounterIndexread-onlycurrentIndex definition for the pm100gfmuxdCntclientInputErrorCounter table
1.3.6.1.4.1.20044.111.4.2.112.1.2Columnpm100gfmuxdCntclientInputErrorCounterValuePortnread-onlycurrentClient Input Errors :This counter gives the number of SM-BIP8 (OTU4) or 66B/64B disparities (100GbE) on client port <Help> This counter gives the number of SM-…
1.3.6.1.4.1.20044.111.4.2.112.1.3Columnpm100gfmuxdCntclientInputErrorCounterErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the BIP8 error counter value is invalid on Port
1.3.6.1.4.1.20044.111.4.2.112.1.4Columnpm100gfmuxdCntclientInputErrorCounterOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a BIP8 error counter overload on Port
1.3.6.1.4.1.20044.111.4.2.144Tablepm100gfmuxdCntclientCbipCounterTablenot-accessiblecurrentList of pm100gfmuxdCntclientCbipCounter Article
1.3.6.1.4.1.20044.111.4.2.144.1Rowpm100gfmuxdCntclientCbipCounterEntrynot-accessiblecurrentRow definition for the pm100gfmuxdCntclientCbipCounter table
1.3.6.1.4.1.20044.111.4.2.144.1.1Columnpm100gfmuxdCntclientCbipCounterIndexread-onlycurrentIndex definition for the pm100gfmuxdCntclientCbipCounter table
1.3.6.1.4.1.20044.111.4.2.144.1.2Columnpm100gfmuxdCntclientCbipCounterValuePortnread-onlycurrentClient Output Errors :This counter gives the number of SM-BIP8 (OTU4) or 66B/64B disparities (100GbE) on client port <Help> This counter gives the number of SM…
1.3.6.1.4.1.20044.111.4.2.144.1.3Columnpm100gfmuxdCntclientCbipCounterErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the BIP8 error counter value is invalid on Port
1.3.6.1.4.1.20044.111.4.2.144.1.4Columnpm100gfmuxdCntclientCbipCounterOverloadPortnread-onlycurrentClient CBIP Counter Overload :This OID when set indicates a BIP8 error counter overload on Port
1.3.6.1.4.1.20044.111.4.3Nodepm100gfmuxdCntLine
1.3.6.1.4.1.20044.111.4.3.192Tablepm100gfmuxdCntlocalLineSmBip8ErrorCounterTablenot-accessiblecurrentList of pm100gfmuxdCntlocalLineSmBip8ErrorCounter Article
1.3.6.1.4.1.20044.111.4.3.192.1Rowpm100gfmuxdCntlocalLineSmBip8ErrorCounterEntrynot-accessiblecurrentRow definition for the pm100gfmuxdCntlocalLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.111.4.3.192.1.1Columnpm100gfmuxdCntlocalLineSmBip8ErrorCounterIndexread-onlycurrentIndex definition for the pm100gfmuxdCntlocalLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.111.4.3.192.1.2Columnpm100gfmuxdCntlocalLineSmBip8ErrorCounterValuePortnread-onlycurrentLine SM BIP8 Errors :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC <Help> This counter gives the current Bit Error Rate (residua…
1.3.6.1.4.1.20044.111.4.3.192.1.3Columnpm100gfmuxdCntlocalLineSmBip8ErrorCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the B1 error counter value is invalid on Port
1.3.6.1.4.1.20044.111.4.3.192.1.4Columnpm100gfmuxdCntlocalLineSmBip8ErrorCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a B1 error counter overload on Port
1.3.6.1.4.1.20044.111.4.3.193Tablepm100gfmuxdCntlocalLineFecCorrectedErrorsCounterTablenot-accessiblecurrentList of pm100gfmuxdCntlocalLineFecCorrectedErrorsCounter Article
1.3.6.1.4.1.20044.111.4.3.193.1Rowpm100gfmuxdCntlocalLineFecCorrectedErrorsCounterEntrynot-accessiblecurrentRow definition for the pm100gfmuxdCntlocalLineFecCorrectedErrorsCounter table
1.3.6.1.4.1.20044.111.4.3.193.1.1Columnpm100gfmuxdCntlocalLineFecCorrectedErrorsCounterIndexread-onlycurrentIndex definition for the pm100gfmuxdCntlocalLineFecCorrectedErrorsCounter table
1.3.6.1.4.1.20044.111.4.3.193.1.2Columnpm100gfmuxdCntlocalLineFecCorrectedErrorsCounterValuePortnread-onlycurrentLine Input HD FEC Corrected Errors :This OID gives the current Bit Error Rate before the Hard Decision FEC <Help> This counter gives the current Bit Error Rate…
1.3.6.1.4.1.20044.111.4.3.193.1.3Columnpm100gfmuxdCntlocalLineFecCorrectedErrorsCounterErrorPortnread-onlycurrentFEC Counter Error :This bit when set indicates the FEC corrected errors counter value is invalid on Line
1.3.6.1.4.1.20044.111.4.3.193.1.4Columnpm100gfmuxdCntlocalLineFecCorrectedErrorsCounterOverloadPortnread-onlycurrentFEC Counter Overload :This bit when set indicates a FEC corrected errors counter overload on Line
1.3.6.1.4.1.20044.111.4.3.194Tablepm100gfmuxdCntremoteLineSmBip8ErrorCounterTablenot-accessiblecurrentList of pm100gfmuxdCntremoteLineSmBip8ErrorCounter Article
1.3.6.1.4.1.20044.111.4.3.194.1Rowpm100gfmuxdCntremoteLineSmBip8ErrorCounterEntrynot-accessiblecurrentRow definition for the pm100gfmuxdCntremoteLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.111.4.3.194.1.1Columnpm100gfmuxdCntremoteLineSmBip8ErrorCounterIndexread-onlycurrentIndex definition for the pm100gfmuxdCntremoteLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.111.4.3.194.1.2Columnpm100gfmuxdCntremoteLineSmBip8ErrorCounterValuePortnread-onlycurrentRemote SM BIP8 :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC on the remote side <Help> This counter gives the current Bit Error…
1.3.6.1.4.1.20044.111.4.3.194.1.3Columnpm100gfmuxdCntremoteLineSmBip8ErrorCounterErrorPortnread-onlycurrentRemote Counter Error :
1.3.6.1.4.1.20044.111.4.3.194.1.4Columnpm100gfmuxdCntremoteLineSmBip8ErrorCounterOverloadPortnread-onlycurrentRemote Counter Overload :
1.3.6.1.4.1.20044.111.4.3.195Tablepm100gfmuxdCntlineDfrmTimCntTablenot-accessiblecurrentList of pm100gfmuxdCntlineDfrmTimCnt Article
1.3.6.1.4.1.20044.111.4.3.195.1Rowpm100gfmuxdCntlineDfrmTimCntEntrynot-accessiblecurrentRow definition for the pm100gfmuxdCntlineDfrmTimCnt table
1.3.6.1.4.1.20044.111.4.3.195.1.1Columnpm100gfmuxdCntlineDfrmTimCntIndexread-onlycurrentIndex definition for the pm100gfmuxdCntlineDfrmTimCnt table
1.3.6.1.4.1.20044.111.4.3.195.1.2Columnpm100gfmuxdCntlineDfrmTimCntValuePortnread-onlycurrentLine Timer Counter :
1.3.6.1.4.1.20044.111.4.3.195.1.3Columnpm100gfmuxdCntlineDfrmTimCntErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.111.4.3.195.1.4Columnpm100gfmuxdCntlineDfrmTimCntOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.111.4.3.196Tablepm100gfmuxdCntlocalLineTrscvPreSdFecErrorCounterTablenot-accessiblecurrentList of pm100gfmuxdCntlocalLineTrscvPreSdFecErrorCounter Article
1.3.6.1.4.1.20044.111.4.3.196.1Rowpm100gfmuxdCntlocalLineTrscvPreSdFecErrorCounterEntrynot-accessiblecurrentRow definition for the pm100gfmuxdCntlocalLineTrscvPreSdFecErrorCounter table
1.3.6.1.4.1.20044.111.4.3.196.1.1Columnpm100gfmuxdCntlocalLineTrscvPreSdFecErrorCounterIndexread-onlycurrentIndex definition for the pm100gfmuxdCntlocalLineTrscvPreSdFecErrorCounter table
1.3.6.1.4.1.20044.111.4.3.196.1.2Columnpm100gfmuxdCntlocalLineTrscvPreSdFecErrorCounterValuePortnread-onlycurrentLine Pre FEC Errors :This OID gives the current Bit Error Rate before the FEC <Help> This counter gives the current Bit Error Rate before the FEC
1.3.6.1.4.1.20044.111.4.3.196.1.3Columnpm100gfmuxdCntlocalLineTrscvPreSdFecErrorCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.111.4.3.196.1.4Columnpm100gfmuxdCntlocalLineTrscvPreSdFecErrorCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.111.4.3.197Tablepm100gfmuxdCntlocalLineTrscvUncorrectedSdFecErrorCounterTablenot-accessiblecurrentList of pm100gfmuxdCntlocalLineTrscvUncorrectedSdFecErrorCounter Article
1.3.6.1.4.1.20044.111.4.3.197.1Rowpm100gfmuxdCntlocalLineTrscvUncorrectedSdFecErrorCounterEntrynot-accessiblecurrentRow definition for the pm100gfmuxdCntlocalLineTrscvUncorrectedSdFecErrorCounter table
1.3.6.1.4.1.20044.111.4.3.197.1.1Columnpm100gfmuxdCntlocalLineTrscvUncorrectedSdFecErrorCounterIndexread-onlycurrentIndex definition for the pm100gfmuxdCntlocalLineTrscvUncorrectedSdFecErrorCounter table
1.3.6.1.4.1.20044.111.4.3.197.1.2Columnpm100gfmuxdCntlocalLineTrscvUncorrectedSdFecErrorCounterValuePortnread-onlycurrentUncorrected FEC Errors :This OID gives the current Bit Error Rate after the Soft Decision FEC (residual) <Help> This counter gives the current Bit Error Rate a…
1.3.6.1.4.1.20044.111.4.3.197.1.3Columnpm100gfmuxdCntlocalLineTrscvUncorrectedSdFecErrorCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.111.4.3.197.1.4Columnpm100gfmuxdCntlocalLineTrscvUncorrectedSdFecErrorCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.111.4.3.198Tablepm100gfmuxdCntlocalLineTrscvPreSdFecBitCounterTablenot-accessiblecurrentList of pm100gfmuxdCntlocalLineTrscvPreSdFecBitCounter Article
1.3.6.1.4.1.20044.111.4.3.198.1Rowpm100gfmuxdCntlocalLineTrscvPreSdFecBitCounterEntrynot-accessiblecurrentRow definition for the pm100gfmuxdCntlocalLineTrscvPreSdFecBitCounter table
1.3.6.1.4.1.20044.111.4.3.198.1.1Columnpm100gfmuxdCntlocalLineTrscvPreSdFecBitCounterIndexread-onlycurrentIndex definition for the pm100gfmuxdCntlocalLineTrscvPreSdFecBitCounter table
1.3.6.1.4.1.20044.111.4.3.198.1.2Columnpm100gfmuxdCntlocalLineTrscvPreSdFecBitCounterValuePortnread-onlycurrentPre-SD FEC Bit Counter :This OID gives the current Bit count before the Soft Decision FEC <Help> This counter gives the current Bit Count before the Soft Decis…
1.3.6.1.4.1.20044.111.4.3.198.1.3Columnpm100gfmuxdCntlocalLineTrscvPreSdFecBitCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.111.4.3.198.1.4Columnpm100gfmuxdCntlocalLineTrscvPreSdFecBitCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.111.4.3.199Tablepm100gfmuxdCntlocalLineTrscvUncorrectedSdFecBitCounterTablenot-accessiblecurrentList of pm100gfmuxdCntlocalLineTrscvUncorrectedSdFecBitCounter Article
1.3.6.1.4.1.20044.111.4.3.199.1Rowpm100gfmuxdCntlocalLineTrscvUncorrectedSdFecBitCounterEntrynot-accessiblecurrentRow definition for the pm100gfmuxdCntlocalLineTrscvUncorrectedSdFecBitCounter table
1.3.6.1.4.1.20044.111.4.3.199.1.1Columnpm100gfmuxdCntlocalLineTrscvUncorrectedSdFecBitCounterIndexread-onlycurrentIndex definition for the pm100gfmuxdCntlocalLineTrscvUncorrectedSdFecBitCounter table
1.3.6.1.4.1.20044.111.4.3.199.1.2Columnpm100gfmuxdCntlocalLineTrscvUncorrectedSdFecBitCounterValuePortnread-onlycurrentUncorrected SD FEC Bit Counter :This OID gives the current Bit count after the Soft Decision FEC (residual) <Help> This counter gives the current Bit Count aft…
1.3.6.1.4.1.20044.111.4.3.199.1.3Columnpm100gfmuxdCntlocalLineTrscvUncorrectedSdFecBitCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.111.4.3.199.1.4Columnpm100gfmuxdCntlocalLineTrscvUncorrectedSdFecBitCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.111.6Nodepm100gfmuxdcontrolsWrite
1.3.6.1.4.1.20044.111.6.1Nodepm100gfmuxdCtrlOther
1.3.6.1.4.1.20044.111.6.1.1Nodepm100gfmuxdCtrlconfMgnt1
1.3.6.1.4.1.20044.111.6.1.1.1Scalarpm100gfmuxdCtrlConf1Load1read-writecurrentLoad Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM.
1.3.6.1.4.1.20044.111.6.1.1.2Scalarpm100gfmuxdCtrlConf2Load1read-writecurrentLoad Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM.
1.3.6.1.4.1.20044.111.6.1.1.10Scalarpm100gfmuxdCtrlConf2Flash1read-writecurrentWrite Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura…
1.3.6.1.4.1.20044.111.6.1.1.14Scalarpm100gfmuxdCtrlConf2Clear1read-writecurrentClear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o…
1.3.6.1.4.1.20044.111.6.1.4Nodepm100gfmuxdCtrlsynth4
1.3.6.1.4.1.20044.111.6.1.4.1Scalarpm100gfmuxdCtrlCorrelatOnread-writecurrentEnable Alarm Correlation :This OID enables the alarm correlation in the PM.
1.3.6.1.4.1.20044.111.6.1.4.2Scalarpm100gfmuxdCtrlCorrelatOffread-writecurrentDisable Alarm Correlation :This OID disables the alarm correlation in the PM.
1.3.6.1.4.1.20044.111.6.1.5Nodepm100gfmuxdCtrlswMgnt
1.3.6.1.4.1.20044.111.6.1.5.2Scalarpm100gfmuxdCtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> …
1.3.6.1.4.1.20044.111.6.1.5.3Scalarpm100gfmuxdCtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th…
1.3.6.1.4.1.20044.111.6.1.5.5Scalarpm100gfmuxdCtrlLoadSwBank1read-writecurrentSet Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW…
1.3.6.1.4.1.20044.111.6.1.5.6Scalarpm100gfmuxdCtrlLoadSwBank2read-writecurrentSet Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S…
1.3.6.1.4.1.20044.111.6.1.6Nodepm100gfmuxdCtrlgwMgnt
1.3.6.1.4.1.20044.111.6.1.6.1Scalarpm100gfmuxdCtrlCurrentGwResetread-writecurrentActive Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting.
1.3.6.1.4.1.20044.111.6.1.6.5Scalarpm100gfmuxdCtrlLoadGwBank1read-writecurrentSet Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.111.6.1.6.6Scalarpm100gfmuxdCtrlLoadGwBank2read-writecurrentSet Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.111.6.1.6.7Scalarpm100gfmuxdCtrlLoadGwBank3read-writecurrentSet Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.111.6.1.6.8Scalarpm100gfmuxdCtrlLoadGwBank4read-writecurrentSet Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.111.6.1.192Nodepm100gfmuxdCtrlledTest
1.3.6.1.4.1.20044.111.6.1.192.1Scalarpm100gfmuxdCtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.111.6.1.192.2Scalarpm100gfmuxdCtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.111.6.1.192.3Scalarpm100gfmuxdCtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.111.6.1.201Nodepm100gfmuxdCtrlinitSwitchMarvell
1.3.6.1.4.1.20044.111.6.1.201.1Scalarpm100gfmuxdCtrlInitSwitchMarvellread-writecurrentSwitch Initialization :This OID operates an initialization of the switch managed through the module <Help> This control activates an initialization of the swit…
1.3.6.1.4.1.20044.111.6.1.259Nodepm100gfmuxdCtrlresetCount
1.3.6.1.4.1.20044.111.6.1.259.1Scalarpm100gfmuxdCtrlResetcountread-writecurrentModule Count Global Reset :This OID resets all the errors counters on the module <Help > This control initiates a reset of the errors counters on the module
1.3.6.1.4.1.20044.111.6.1.260Nodepm100gfmuxdCtrlresetRmon
1.3.6.1.4.1.20044.111.6.1.260.1Scalarpm100gfmuxdCtrlResetrmonread-writecurrentModule Rmon Global Reset :This OID resets all the Rmon counters on the module <Help > This control initiates a reset of the Rmon counters on the module
1.3.6.1.4.1.20044.111.6.1.261Nodepm100gfmuxdCtrlresetMeasurements
1.3.6.1.4.1.20044.111.6.1.261.1Scalarpm100gfmuxdCtrlResetmeasurementsread-writecurrentManagement Meas Global Reset :This OID resets some measurements on the management <Help > This control initiates a reset of some measurements on the management
1.3.6.1.4.1.20044.111.6.2Nodepm100gfmuxdCtrlClient
1.3.6.1.4.1.20044.111.6.2.16Tablepm100gfmuxdCtrlaccessLoopTablenot-accessiblecurrentList of pm100gfmuxdCtrlaccessLoop Article
1.3.6.1.4.1.20044.111.6.2.16.1Rowpm100gfmuxdCtrlaccessLoopEntrynot-accessiblecurrentRow definition for the pm100gfmuxdCtrlaccessLoop table
1.3.6.1.4.1.20044.111.6.2.16.1.1Columnpm100gfmuxdCtrlaccessLoopIndexread-onlycurrentIndex definition for the pm100gfmuxdCtrlaccessLoop table
1.3.6.1.4.1.20044.111.6.2.16.1.2Columnpm100gfmuxdCtrlaccessLoopPortnread-writecurrentClient Facility Loopback :This OID, when set at '1' puts the client port in loopback, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. <Help…
1.3.6.1.4.1.20044.111.6.2.17Tablepm100gfmuxdCtrlclientLoopToLineTablenot-accessiblecurrentList of pm100gfmuxdCtrlclientLoopToLine Article
1.3.6.1.4.1.20044.111.6.2.17.1Rowpm100gfmuxdCtrlclientLoopToLineEntrynot-accessiblecurrentRow definition for the pm100gfmuxdCtrlclientLoopToLine table
1.3.6.1.4.1.20044.111.6.2.17.1.1Columnpm100gfmuxdCtrlclientLoopToLineIndexread-onlycurrentIndex definition for the pm100gfmuxdCtrlclientLoopToLine table
1.3.6.1.4.1.20044.111.6.2.17.1.2Columnpm100gfmuxdCtrlclientLoopToLinePortnread-writecurrentClient Terminal Loopback :This OID, when set, puts the client port in loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.<Help> This control ena…
1.3.6.1.4.1.20044.111.6.2.21Tablepm100gfmuxdCtrlcsfUpInsTablenot-accessiblecurrentList of pm100gfmuxdCtrlcsfUpIns Article
1.3.6.1.4.1.20044.111.6.2.21.1Rowpm100gfmuxdCtrlcsfUpInsEntrynot-accessiblecurrentRow definition for the pm100gfmuxdCtrlcsfUpIns table
1.3.6.1.4.1.20044.111.6.2.21.1.1Columnpm100gfmuxdCtrlcsfUpInsIndexread-onlycurrentIndex definition for the pm100gfmuxdCtrlcsfUpIns table
1.3.6.1.4.1.20044.111.6.2.21.1.2Columnpm100gfmuxdCtrlcsfUpInsPortnread-writecurrentClient Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo…
1.3.6.1.4.1.20044.111.6.2.22Tablepm100gfmuxdCtrlcaisDwInsTablenot-accessiblecurrentList of pm100gfmuxdCtrlcaisDwIns Article
1.3.6.1.4.1.20044.111.6.2.22.1Rowpm100gfmuxdCtrlcaisDwInsEntrynot-accessiblecurrentRow definition for the pm100gfmuxdCtrlcaisDwIns table
1.3.6.1.4.1.20044.111.6.2.22.1.1Columnpm100gfmuxdCtrlcaisDwInsIndexread-onlycurrentIndex definition for the pm100gfmuxdCtrlcaisDwIns table
1.3.6.1.4.1.20044.111.6.2.22.1.2Columnpm100gfmuxdCtrlcaisDwInsPortnread-writecurrentClient AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port
1.3.6.1.4.1.20044.111.6.2.262Tablepm100gfmuxdCtrlclientResetAllCountTablenot-accessiblecurrentList of pm100gfmuxdCtrlclientResetAllCount Article
1.3.6.1.4.1.20044.111.6.2.262.1Rowpm100gfmuxdCtrlclientResetAllCountEntrynot-accessiblecurrentRow definition for the pm100gfmuxdCtrlclientResetAllCount table
1.3.6.1.4.1.20044.111.6.2.262.1.1Columnpm100gfmuxdCtrlclientResetAllCountIndexread-onlycurrentIndex definition for the pm100gfmuxdCtrlclientResetAllCount table
1.3.6.1.4.1.20044.111.6.2.262.1.2Columnpm100gfmuxdCtrlclientResetAllCountsPortnread-writecurrentClient Counters Reset :This OID resets every counter on the client port <Help> This control operates a reset on the statistics current ,previous and history cl…
1.3.6.1.4.1.20044.111.6.3Nodepm100gfmuxdCtrlLine
1.3.6.1.4.1.20044.111.6.3.64Tablepm100gfmuxdCtrlcommAccessLoopTablenot-accessiblecurrentList of pm100gfmuxdCtrlcommAccessLoop Article
1.3.6.1.4.1.20044.111.6.3.64.1Rowpm100gfmuxdCtrlcommAccessLoopEntrynot-accessiblecurrentRow definition for the pm100gfmuxdCtrlcommAccessLoop table
1.3.6.1.4.1.20044.111.6.3.64.1.1Columnpm100gfmuxdCtrlcommAccessLoopIndexread-onlycurrentIndex definition for the pm100gfmuxdCtrlcommAccessLoop table
1.3.6.1.4.1.20044.111.6.3.64.1.2Columnpm100gfmuxdCtrlcommAccessLoopPortnread-writecurrentLine Terminal Loopback :This OID, when set, puts the module in common access loopback, looping the 100 Gb/s output signal on the 100 Gb/s input.<Help> This con…
1.3.6.1.4.1.20044.111.6.3.66Tablepm100gfmuxdCtrllineLoopTablenot-accessiblecurrentList of pm100gfmuxdCtrllineLoop Article
1.3.6.1.4.1.20044.111.6.3.66.1Rowpm100gfmuxdCtrllineLoopEntrynot-accessiblecurrentRow definition for the pm100gfmuxdCtrllineLoop table
1.3.6.1.4.1.20044.111.6.3.66.1.1Columnpm100gfmuxdCtrllineLoopIndexread-onlycurrentIndex definition for the pm100gfmuxdCtrllineLoop table
1.3.6.1.4.1.20044.111.6.3.66.1.2Columnpm100gfmuxdCtrllineLoopPortnread-writecurrentLine Facility Loopback :This OID, when set at '1' puts the module in line loopback mode, looping the received 100 Gb/s signal on the transmit 100 Gb/s output. …
1.3.6.1.4.1.20044.111.6.3.263Tablepm100gfmuxdCtrllineResetAllCountTablenot-accessiblecurrentList of pm100gfmuxdCtrllineResetAllCount Article
1.3.6.1.4.1.20044.111.6.3.263.1Rowpm100gfmuxdCtrllineResetAllCountEntrynot-accessiblecurrentRow definition for the pm100gfmuxdCtrllineResetAllCount table
1.3.6.1.4.1.20044.111.6.3.263.1.1Columnpm100gfmuxdCtrllineResetAllCountIndexread-onlycurrentIndex definition for the pm100gfmuxdCtrllineResetAllCount table
1.3.6.1.4.1.20044.111.6.3.263.1.2Columnpm100gfmuxdCtrllineResetAllCountsPortnread-writecurrentLine Counters Reset :This OID resets every counter on the line port <Help> This control operates a reset on the statistics current ,previous and history line p…
1.3.6.1.4.1.20044.111.7Nodepm100gfmuxdri
1.3.6.1.4.1.20044.111.7.1Nodepm100gfmuxdriTable
1.3.6.1.4.1.20044.111.7.1.1Tablepm100gfmuxdRinvSfpTablenot-accessiblecurrentList of the SFPs on the selected module
1.3.6.1.4.1.20044.111.7.1.1.1Rowpm100gfmuxdRinvSfpEntrynot-accessiblecurrentRow definition for the SFP table
1.3.6.1.4.1.20044.111.7.1.1.1.1Columnpm100gfmuxdRinvSfpIndexread-onlycurrentIndex for SFP table
1.3.6.1.4.1.20044.111.7.1.1.1.2Columnpm100gfmuxdRinvsfpread-onlycurrentInventory for the SFP: This OID contains the inventory for the SFP
1.3.6.1.4.1.20044.111.7.1.2Tablepm100gfmuxdRinvLineTablenot-accessiblecurrentList of the XFPs on the selected module
1.3.6.1.4.1.20044.111.7.1.2.1Rowpm100gfmuxdRinvLineEntrynot-accessiblecurrentRow definition for the XFP table
1.3.6.1.4.1.20044.111.7.1.2.1.1Columnpm100gfmuxdRinvLineIndexread-onlycurrentIndex for XFP table
1.3.6.1.4.1.20044.111.7.1.2.1.2Columnpm100gfmuxdRinvxfpLineread-onlycurrentInventory for the XFP: This OID contains the inventory for the XFP
1.3.6.1.4.1.20044.111.7.2Scalarpm100gfmuxdRinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.111.7.3Scalarpm100gfmuxdRinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.111.7.4Scalarpm100gfmuxdRinvModulePlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.111.7.5Scalarpm100gfmuxdRinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.111.7.6Scalarpm100gfmuxdRinvGwPlatformread-onlycurrentGW platform description: This OID contains the description of the Gateware platform.
1.3.6.1.4.1.20044.111.8Nodepm100gfmuxddownload
1.3.6.1.4.1.20044.111.8.1Nodepm100gfmuxdDwlOther
1.3.6.1.4.1.20044.111.8.1.0Nodepm100gfmuxdDwlrestartProcess
1.3.6.1.4.1.20044.111.8.1.0.1Scalarpm100gfmuxdDwlWarmRestartProcessedread-onlycurrentWarm Restart :This OID indicates that the module last restart was a Warm RESTART
1.3.6.1.4.1.20044.111.8.1.0.2Scalarpm100gfmuxdDwlColdRestartProcessedread-onlycurrentCold Restart :This OID indicates that the module last restart was a Cold RESTART
1.3.6.1.4.1.20044.111.8.1.1Nodepm100gfmuxdDwlswBanksUsed
1.3.6.1.4.1.20044.111.8.1.1.1Scalarpm100gfmuxdDwlSwBank1Usedread-onlycurrentSW Bank 1 Active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby
1.3.6.1.4.1.20044.111.8.1.1.2Scalarpm100gfmuxdDwlSwBank2Usedread-onlycurrentSW Bank 2 Active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby
1.3.6.1.4.1.20044.111.8.1.1.5Scalarpm100gfmuxdDwlSwBank1Notemptyread-onlycurrentSW Bank 1 Loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package
1.3.6.1.4.1.20044.111.8.1.1.6Scalarpm100gfmuxdDwlSwBank2Notemptyread-onlycurrentSW Bank 2 Loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package
1.3.6.1.4.1.20044.111.8.1.2Nodepm100gfmuxdDwlgwBanksUsed
1.3.6.1.4.1.20044.111.8.1.2.1Scalarpm100gfmuxdDwlGwBank1Usedread-onlycurrentGW Bank 1 Active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby
1.3.6.1.4.1.20044.111.8.1.2.2Scalarpm100gfmuxdDwlGwBank2Usedread-onlycurrentGW Bank 2 Active :This OID indicates the module is working on GW bank 2
1.3.6.1.4.1.20044.111.8.1.2.3Scalarpm100gfmuxdDwlGwBank3Usedread-onlycurrentGW Bank 3 Active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby
1.3.6.1.4.1.20044.111.8.1.2.4Scalarpm100gfmuxdDwlGwBank4Usedread-onlycurrentGW Bank 4 Active :This OID indicates the module is working on GW bank 4
1.3.6.1.4.1.20044.111.8.1.2.5Scalarpm100gfmuxdDwlGwBank1Notemptyread-onlycurrentGW Bank 1 Loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package
1.3.6.1.4.1.20044.111.8.1.2.6Scalarpm100gfmuxdDwlGwBank2Notemptyread-onlycurrentGW Bank 2 Loaded :This OID indicates a gateware is loaded in GW bank 2
1.3.6.1.4.1.20044.111.8.1.2.7Scalarpm100gfmuxdDwlGwBank3Notemptyread-onlycurrentGW Bank 3 Loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package
1.3.6.1.4.1.20044.111.8.1.2.8Scalarpm100gfmuxdDwlGwBank4Notemptyread-onlycurrentGW Bank 4 Loaded :This OID indicates a gateware is loaded in GW bank 4
1.3.6.1.4.1.20044.111.8.2Nodepm100gfmuxdDwlClient
1.3.6.1.4.1.20044.111.8.3Nodepm100gfmuxdDwlLine
1.3.6.1.4.1.20044.111.9Nodepm100gfmuxdConfig
1.3.6.1.4.1.20044.111.9.1Nodepm100gfmuxdCfgAccessCAisCsf
1.3.6.1.4.1.20044.111.9.1.1Tablepm100gfmuxdCfgClientcaiscsfTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.111.9.1.1.1Rowpm100gfmuxdCfgClientcaiscsfEntrynot-accessiblecurrentRow definition for the accessCAisCsf table
1.3.6.1.4.1.20044.111.9.1.1.1.1Columnpm100gfmuxdCfgClientcaiscsfIndexread-onlycurrentIndex definition for the clientcaiscsf table
1.3.6.1.4.1.20044.111.9.1.1.1.3Columnpm100gfmuxdCfgReservePortnread-writecurrentCAIS mode on Client Port :This register enables/disables port laser shutdown on CAIS insertion condition
1.3.6.1.4.1.20044.111.9.2Nodepm100gfmuxdCfgStartup
1.3.6.1.4.1.20044.111.9.2.1Tablepm100gfmuxdCfgClientStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.111.9.2.1.1Rowpm100gfmuxdCfgClientStartupEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.111.9.2.1.1.1Columnpm100gfmuxdCfgClientStartupIndexread-onlycurrentIndex definition for the clientStartup table
1.3.6.1.4.1.20044.111.9.2.1.1.3Columnpm100gfmuxdCfgSystConfPortPortnread-writecurrentDefault Settings on Client Port :This register configures the default initialisation settings on the port.
1.3.6.1.4.1.20044.111.9.2.1.1.4Columnpm100gfmuxdCfgNetConfPortPortnread-writecurrentDefault Settings on Client Port :This register configures the default initialisation settings on the port.
1.3.6.1.4.1.20044.111.9.2.1.1.14Columnpm100gfmuxdCfgOptionsPortPortnread-writecurrentDefault Options on Client Port :This register configures the default options on the port.
1.3.6.1.4.1.20044.111.9.2.2Tablepm100gfmuxdCfgLineStartupThreshTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.111.9.2.2.1Rowpm100gfmuxdCfgLineStartupThreshEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.111.9.2.2.1.1Columnpm100gfmuxdCfgLineStartupThreshIndexread-onlycurrentIndex definition for the lineStartupThresh table
1.3.6.1.4.1.20044.111.9.2.2.1.3Columnpm100gfmuxdCfgSystConfLinePortnread-writecurrentDefault Settings on Line :This register configures the default initialisation settings on Line
1.3.6.1.4.1.20044.111.9.2.2.1.14Columnpm100gfmuxdCfgOptionsLinePortnread-writecurrentDefault Options on Line :This register configures the default options on the line
1.3.6.1.4.1.20044.111.9.2.3Tablepm100gfmuxdCfgLineStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.111.9.2.3.1Rowpm100gfmuxdCfgLineStartupEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.111.9.2.3.1.1Columnpm100gfmuxdCfgLineStartupIndexread-onlycurrentIndex definition for the lineStartup table
1.3.6.1.4.1.20044.111.9.2.3.1.3Columnpm100gfmuxdCfgSystConfMsaLinePortnread-writecurrentDefault settings on TRX :This register configures the default initialisation settings on TRX
1.3.6.1.4.1.20044.111.9.2.3.1.6Columnpm100gfmuxdCfgLineInputPowerHighAlarmPortnread-writedeprecatedDefault settings on alarm threshold :This register configures the default initialisation settings on a threshold
1.3.6.1.4.1.20044.111.9.2.3.1.7Columnpm100gfmuxdCfgLineInputPowerHighWarningPortnread-writedeprecatedDefault settings on warning threshold :This register configures the default initialisation settings on a threshold
1.3.6.1.4.1.20044.111.9.2.3.1.8Columnpm100gfmuxdCfgLineInputPowerLowWarningPortnread-writedeprecatedDefault settings on warning threshold :This register configures the default initialisation settings on a threshold
1.3.6.1.4.1.20044.111.9.2.3.1.9Columnpm100gfmuxdCfgLineInputPowerLowAlarmPortnread-writedeprecatedDefault settings on alarm threshold :This register configures the default initialisation settings on a threshold
1.3.6.1.4.1.20044.111.9.2.3.1.10Columnpm100gfmuxdCfgLineOutputPowerHighAlarmPortnread-writedeprecatedDefault settings on alarm threshold :This register configures the default initialisation settings on a threshold
1.3.6.1.4.1.20044.111.9.2.3.1.11Columnpm100gfmuxdCfgLineOutputPowerHighWarningPortnread-writedeprecatedDefault settings on warning threshold :This register configures the default initialisation settings on a threshold
1.3.6.1.4.1.20044.111.9.2.3.1.12Columnpm100gfmuxdCfgLineOutputPowerLowWarningPortnread-writedeprecatedDefault settings on warning threshold :This register configures the default initialisation settings on a threshold
1.3.6.1.4.1.20044.111.9.2.3.1.13Columnpm100gfmuxdCfgLineOutputPowerLowAlarmPortnread-writedeprecatedDefault settings on alarm threshold :This register configures the default initialisation settings on a threshold
1.3.6.1.4.1.20044.111.9.2.3.1.14Columnpm100gfmuxdCfgLineLossOfSignalPortnread-writedeprecatedDefault settings on Los threshold :This register configures the default initialisation settings on a threshold
1.3.6.1.4.1.20044.111.9.3Nodepm100gfmuxdCfgLabels
1.3.6.1.4.1.20044.111.9.3.1Tablepm100gfmuxdCfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.111.9.3.1.1Rowpm100gfmuxdCfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.111.9.3.1.1.1Columnpm100gfmuxdCfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.111.9.3.1.1.3Columnpm100gfmuxdCfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.111.9.3.2Tablepm100gfmuxdCfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.111.9.3.2.1Rowpm100gfmuxdCfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.111.9.3.2.1.1Columnpm100gfmuxdCfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.111.9.3.2.1.3Columnpm100gfmuxdCfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.111.9.4Nodepm100gfmuxdCfgStartuptlh
1.3.6.1.4.1.20044.111.9.4.1Tablepm100gfmuxdCfgOtxtlhTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.111.9.4.1.1Rowpm100gfmuxdCfgOtxtlhEntrynot-accessiblecurrentRow definition for the startuptlh table
1.3.6.1.4.1.20044.111.9.4.1.1.1Columnpm100gfmuxdCfgOtxtlhIndexread-onlycurrentIndex definition for the otxtlh table
1.3.6.1.4.1.20044.111.9.4.1.1.6Columnpm100gfmuxdCfgLinePwrLaserPortnread-writedeprecatedDefaut Line output Power :This register configures the start-up output power of the Line tranceiver (Unit = dBm)
1.3.6.1.4.1.20044.111.9.4.1.1.7Columnpm100gfmuxdCfgLineFCurrentPortnread-writedeprecatedDefault Line transceiver Tx Channel :This register configures the start-up laser channel of the Line Tx transceiver
1.3.6.1.4.1.20044.111.9.4.1.1.8Columnpm100gfmuxdCfgLineGridCurrentPortnread-writedeprecatedDefault Line transceiver Grid :This register configures the start-up laser grid of the Line transceiver
1.3.6.1.4.1.20044.111.9.4.1.1.9Columnpm100gfmuxdCfgFPortnread-writedeprecatedDefault Line TRX lowest Freq :This register configures the start-up lowest frequency of the Line transceiver
1.3.6.1.4.1.20044.111.9.4.1.1.10Columnpm100gfmuxdCfgRxLineFCurrentPortnread-writedeprecatedDefault Line transceiver Rx Channel :This register configures the start-up laser channel of the Line Rx transceiver
1.3.6.1.4.1.20044.111.9.5Nodepm100gfmuxdCfgOther
1.3.6.1.4.1.20044.111.9.5.1Nodepm100gfmuxdtablemoduleOther
1.3.6.1.4.1.20044.111.9.5.1.5Scalarpm100gfmuxdCfgmoduleModeread-writecurrentDefault settings on Module :This register selects the configuration mode of the module
1.3.6.1.4.1.20044.111.9.10Nodepm100gfmuxdCfgStartuptablefive
1.3.6.1.4.1.20044.111.9.10.1Tablepm100gfmuxdCfgOtxtlhcapabilitiesTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.111.9.10.1.1Rowpm100gfmuxdCfgOtxtlhcapabilitiesEntrynot-accessiblecurrentRow definition for the startuptablefive table
1.3.6.1.4.1.20044.111.9.10.1.1.1Columnpm100gfmuxdCfgOtxtlhcapabilitiesIndexread-onlycurrentIndex definition for the otxtlhcapabilities table
1.3.6.1.4.1.20044.111.9.10.1.1.3Columnpm100gfmuxdCfgComponentTypePortnread-onlydeprecatedComponent parameters :This OID defines the component parameters
1.3.6.1.4.1.20044.111.9.10.1.1.4Columnpm100gfmuxdCfgMiscellaneousPortnread-onlydeprecatedMiscellaneous default settings :This OID defines the miscellaneous parameters
1.3.6.1.4.1.20044.111.9.10.1.1.5Columnpm100gfmuxdCfgFirstChannelPortnread-onlydeprecatedNumber of the first channel of the component :This OID defines the first channel number of the PM
1.3.6.1.4.1.20044.111.9.10.1.1.6Columnpm100gfmuxdCfgLastChannelPortnread-onlydeprecatedNumber of the last channel of the component :This OID defines the last channel number of the PM
1.3.6.1.4.1.20044.111.9.10.1.1.7Columnpm100gfmuxdCfgGridPortnread-onlydeprecatedGrid value of the component :This OID defines the grid of the PM
1.3.6.1.4.1.20044.111.9.257Scalarpm100gfmuxdCfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.111.10Nodepm100gfmuxdtraps
1.3.6.1.4.1.20044.111.10.2Scalarpm100gfmuxdtrapPortNumberread-onlycurrentLast port which generates a trap
1.3.6.1.4.1.20044.111.10.3Scalarpm100gfmuxdtrapLineNumberread-onlycurrentLast Line which generates a trap
1.3.6.1.4.1.20044.111.10.4Scalarpm100gfmuxdtrapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.111.10.30Notificationpm100gfmuxdLineTrapNotUrgentGoesOncurrentNot urgent Line default is activated
1.3.6.1.4.1.20044.111.10.31Notificationpm100gfmuxdLineTrapNotUrgentGoesOffcurrentNot urgent Line default disappeared
1.3.6.1.4.1.20044.111.10.32Notificationpm100gfmuxdLineTrapUrgentGoesOncurrentUrgent Line default is activated
1.3.6.1.4.1.20044.111.10.33Notificationpm100gfmuxdLineTrapUrgentGoesOffcurrentUrgent Line default disappeared
1.3.6.1.4.1.20044.111.10.34Notificationpm100gfmuxdLineTrapCritGoesOncurrentCritical Line default is activated
1.3.6.1.4.1.20044.111.10.35Notificationpm100gfmuxdLineTrapCritGoesOffcurrentCritical Line default disappeared
1.3.6.1.4.1.20044.111.10.40Notificationpm100gfmuxdClientTrapNotUrgentGoesOncurrentNot urgent client default is activated
1.3.6.1.4.1.20044.111.10.41Notificationpm100gfmuxdClientTrapNotUrgentGoesOffcurrentNot urgent client default disappeared
1.3.6.1.4.1.20044.111.10.42Notificationpm100gfmuxdClientTrapUrgentGoesOncurrentUrgent client default is activated
1.3.6.1.4.1.20044.111.10.43Notificationpm100gfmuxdClientTrapUrgentGoesOffcurrentUrgent client default disappeared
1.3.6.1.4.1.20044.111.10.44Notificationpm100gfmuxdClientTrapCritGoesOncurrentCritical client default is activated
1.3.6.1.4.1.20044.111.10.45Notificationpm100gfmuxdClientTrapCritGoesOffcurrentCritical client default disappeared
1.3.6.1.4.1.20044.111.10.50Notificationpm100gfmuxdPowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.111.10.51Notificationpm100gfmuxdPowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared
1.3.6.1.4.1.20044.111.11Nodepm100gfmuxdMonitoring
1.3.6.1.4.1.20044.111.11.1Nodepm100gfmuxdMonOther
1.3.6.1.4.1.20044.111.11.1.3Nodepm100gfmuxdMonRmon
1.3.6.1.4.1.20044.111.11.2Nodepm100gfmuxdMonClient
1.3.6.1.4.1.20044.111.11.2.4Nodepm100gfmuxdMonClientRmonCounter
1.3.6.1.4.1.20044.111.11.3Nodepm100gfmuxdMonLine
1.3.6.1.4.1.20044.111.11.3.4Nodepm100gfmuxdMonLineRmonCounter
1.3.6.1.4.1.20044.111.11.5Nodepm100gfmuxdMonPerfOther
1.3.6.1.4.1.20044.111.11.5.1Nodepm100gfmuxdMonPerfSync
1.3.6.1.4.1.20044.111.11.5.1.257Scalarpm100gfmuxdPerfEnableread-writecurrentPerf. Mon. Enable :This OID enables the Performance Monitoring application
1.3.6.1.4.1.20044.111.11.5.1.259Scalarpm100gfmuxdPerf15minSyncread-writecurrentPerf. Mon. 15-min sync. :This OID must be used in external synchronisation mode only to send a 15-min synchronisation command
1.3.6.1.4.1.20044.111.11.5.1.260Scalarpm100gfmuxdPerf24hSyncread-writecurrentPerf. Mon. 24-hours sync. :This OID must be used in external synchronisation mode only to send a 24-hours synchronisation command
1.3.6.1.4.1.20044.111.11.5.2Nodepm100gfmuxdMonPerfTimeStamp
1.3.6.1.4.1.20044.111.11.5.2.1Scalarpm100gfmuxdPerf15MinShortread-writecurrent15-min period is short :This OID indicates that the 15-min period lasts less than 890 seconds
1.3.6.1.4.1.20044.111.11.5.2.2Scalarpm100gfmuxdPerf15MinLongread-writecurrent15-min period is long :This OID indicates that the 15-min period lasts more than 910 seconds
1.3.6.1.4.1.20044.111.11.5.2.5Scalarpm100gfmuxdPerf24HoursShortread-writecurrent24-hours period is short :This OID indicates that 24-hours period lasts less than 86390 seconds
1.3.6.1.4.1.20044.111.11.5.2.6Scalarpm100gfmuxdPerf24HoursLongread-writecurrent24-hours period is long :This OID indicates that 24-hours period lasts more than 86410 seconds
1.3.6.1.4.1.20044.111.11.5.2.7Scalarpm100gfmuxdPerfCurrent15MinElapsedTimeread-writecurrentCurrent 15min period Elapsed Time :This OID gives the number of seconds elapsed in the current 15-minutes period
1.3.6.1.4.1.20044.111.11.5.2.8Scalarpm100gfmuxdPerfCurrent24HoursElapsedTimeread-writecurrentCurrent 24hours period Elapsed Time :This OID gives the number of seconds elapsed in the current 24-hours period
1.3.6.1.4.1.20044.111.11.6Nodepm100gfmuxdMonPerfClient
1.3.6.1.4.1.20044.111.11.6.16Tablepm100gfmuxdPerfTelecomInputClientCurrent15StatTablenot-accessiblecurrentList of pm100gfmuxdPerfTelecomInputClientCurrent15Stat Article
1.3.6.1.4.1.20044.111.11.6.16.1Rowpm100gfmuxdPerfTelecomInputClientCurrent15StatEntrynot-accessiblecurrentRow definition for the pm100gfmuxdPerfTelecomInputClientCurrent15Stat table
1.3.6.1.4.1.20044.111.11.6.16.1.1Columnpm100gfmuxdPerfTelecomInputClientCurrent15StatIndexread-onlycurrentIndex definition for the pm100gfmuxdPerfTelecomInputClientCurrent15Stat table
1.3.6.1.4.1.20044.111.11.6.16.1.2Columnpm100gfmuxdPerfTelecomInputClientCurrent15StatInvCvPortnread-onlycurrentCurrent 15-min EBC counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.111.11.6.16.1.3Columnpm100gfmuxdPerfTelecomInputClientCurrent15StatCvValuePortnread-onlycurrentCurrent 15-min EBC counter :This OID gives the current 15-min Coding Violation counter value
1.3.6.1.4.1.20044.111.11.6.16.1.4Columnpm100gfmuxdPerfTelecomInputClientCurrent15StatInvEsPortnread-onlycurrentCurrent 15-min ES counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.16.1.5Columnpm100gfmuxdPerfTelecomInputClientCurrent15StatEsValuePortnread-onlycurrentCurrent 15-min ES counter :This OID gives the current 15-min Errored Second counter value
1.3.6.1.4.1.20044.111.11.6.16.1.6Columnpm100gfmuxdPerfTelecomInputClientCurrent15StatInvSesPortnread-onlycurrentCurrent 15-min SES counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.16.1.7Columnpm100gfmuxdPerfTelecomInputClientCurrent15StatSesValuePortnread-onlycurrentCurrent 15-min SES counter :This OID gives the current 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.111.11.6.16.1.8Columnpm100gfmuxdPerfTelecomInputClientCurrent15StatInvSefsPortnread-onlycurrentCurrent 15-min SEFS counter inv. :This OID indicates that the current 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.16.1.9Columnpm100gfmuxdPerfTelecomInputClientCurrent15StatSefsValuePortnread-onlycurrentCurrent 15-min SEFS counter :This OID gives the current 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.111.11.6.16.1.10Columnpm100gfmuxdPerfTelecomInputClientCurrent15StatInvUasPortnread-onlycurrentCurrent 15-min UAS counter inv. :This OID indicates that the current 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.16.1.11Columnpm100gfmuxdPerfTelecomInputClientCurrent15StatUasValuePortnread-onlycurrentCurrent 15-min UAS counter :This OID gives the current 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.111.11.6.48Tablepm100gfmuxdPerfTelecomInputClientPast15StatHistoryPort1Tablenot-accessiblecurrentList of pm100gfmuxdPerfTelecomInputClientPast15StatHistory Article
1.3.6.1.4.1.20044.111.11.6.48.1Rowpm100gfmuxdPerfTelecomInputClientPast15StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pm100gfmuxdPerfTelecomInputClientPast15StatHistory table
1.3.6.1.4.1.20044.111.11.6.48.1.1Columnpm100gfmuxdPerfTelecomInputClientPast15StatHistoryPort1Indexread-onlycurrentIndex definition for the pm100gfmuxdPerfTelecomInputClientPast15StatHistory table
1.3.6.1.4.1.20044.111.11.6.48.1.2Columnpm100gfmuxdPerfTelecomInputClientPast15StatHistoryInvCvPort1read-onlycurrentPrevious 15-min EBC counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.111.11.6.48.1.3Columnpm100gfmuxdPerfTelecomInputClientPast15StatHistoryCvValuePort1read-onlycurrentPrevious 15-min EBC counter :This OID gives the previous 15-min Coding Violation counter value
1.3.6.1.4.1.20044.111.11.6.48.1.4Columnpm100gfmuxdPerfTelecomInputClientPast15StatHistoryInvEsPort1read-onlycurrentPrevious 15-min ES counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.48.1.5Columnpm100gfmuxdPerfTelecomInputClientPast15StatHistoryEsValuePort1read-onlycurrentPrevious 15-min ES counter :This OID gives the previous 15-min Errored Second counter value
1.3.6.1.4.1.20044.111.11.6.48.1.6Columnpm100gfmuxdPerfTelecomInputClientPast15StatHistoryInvSesPort1read-onlycurrentPrevious 15-min SES counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.48.1.7Columnpm100gfmuxdPerfTelecomInputClientPast15StatHistorySesValuePort1read-onlycurrentPrevious 15-min SES counter :This OID gives the previous 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.111.11.6.48.1.8Columnpm100gfmuxdPerfTelecomInputClientPast15StatHistoryInvSefsPort1read-onlycurrentPrevious 15-min SEFS counter inv. :This OID indicates that the previous 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.48.1.9Columnpm100gfmuxdPerfTelecomInputClientPast15StatHistorySefsValuePort1read-onlycurrentPrevious 15-min SEFS counter :This OID gives the previous 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.111.11.6.48.1.10Columnpm100gfmuxdPerfTelecomInputClientPast15StatHistoryInvUasPort1read-onlycurrentPrevious 15-min UAS counter inv. :This OID indicates that the previous 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.48.1.11Columnpm100gfmuxdPerfTelecomInputClientPast15StatHistoryUasValuePort1read-onlycurrentPrevious 15-min UAS counter :This OID gives the previous 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.111.11.6.80Tablepm100gfmuxdPerfTelecomInputClientCurrent24StatTablenot-accessiblecurrentList of pm100gfmuxdPerfTelecomInputClientCurrent24Stat Article
1.3.6.1.4.1.20044.111.11.6.80.1Rowpm100gfmuxdPerfTelecomInputClientCurrent24StatEntrynot-accessiblecurrentRow definition for the pm100gfmuxdPerfTelecomInputClientCurrent24Stat table
1.3.6.1.4.1.20044.111.11.6.80.1.1Columnpm100gfmuxdPerfTelecomInputClientCurrent24StatIndexread-onlycurrentIndex definition for the pm100gfmuxdPerfTelecomInputClientCurrent24Stat table
1.3.6.1.4.1.20044.111.11.6.80.1.2Columnpm100gfmuxdPerfTelecomInputClientCurrent24StatInvCvPortnread-onlycurrentCurrent 24-hours EBC counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.111.11.6.80.1.3Columnpm100gfmuxdPerfTelecomInputClientCurrent24StatCvValuePortnread-onlycurrentCurrent 24-hours EBC counter :This OID gives the current 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.111.11.6.80.1.4Columnpm100gfmuxdPerfTelecomInputClientCurrent24StatInvEsPortnread-onlycurrentCurrent 24-hours ES counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.80.1.5Columnpm100gfmuxdPerfTelecomInputClientCurrent24StatEsValuePortnread-onlycurrentCurrent 24-hours ES counter :This OID gives the current 24-hours Errored Second counter value
1.3.6.1.4.1.20044.111.11.6.80.1.6Columnpm100gfmuxdPerfTelecomInputClientCurrent24StatInvSesPortnread-onlycurrentCurrent 24-hours SES counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.80.1.7Columnpm100gfmuxdPerfTelecomInputClientCurrent24StatSesValuePortnread-onlycurrentCurrent 24-hours SES counter :This OID gives the current 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.111.11.6.80.1.8Columnpm100gfmuxdPerfTelecomInputClientCurrent24StatInvSefsPortnread-onlycurrentCurrent 24-hours SEFS counter inv. :This OID indicates that the current 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.80.1.9Columnpm100gfmuxdPerfTelecomInputClientCurrent24StatSefsValuePortnread-onlycurrentCurrent 24-hours SEFS counter :This OID gives the current 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.111.11.6.80.1.10Columnpm100gfmuxdPerfTelecomInputClientCurrent24StatInvUasPortnread-onlycurrentCurrent 24-hours UAS counter inv. :This OID indicates that the current 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.80.1.11Columnpm100gfmuxdPerfTelecomInputClientCurrent24StatUasValuePortnread-onlycurrentCurrent 24-hours UAS counter :This OID gives the current 24-hours UnAvailable Second counter value
1.3.6.1.4.1.20044.111.11.6.112Tablepm100gfmuxdPerfTelecomInputClientPast24StatHistoryPort1Tablenot-accessiblecurrentList of pm100gfmuxdPerfTelecomInputClientPast24StatHistory Article
1.3.6.1.4.1.20044.111.11.6.112.1Rowpm100gfmuxdPerfTelecomInputClientPast24StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pm100gfmuxdPerfTelecomInputClientPast24StatHistory table
1.3.6.1.4.1.20044.111.11.6.112.1.1Columnpm100gfmuxdPerfTelecomInputClientPast24StatHistoryPort1Indexread-onlycurrentIndex definition for the pm100gfmuxdPerfTelecomInputClientPast24StatHistory table
1.3.6.1.4.1.20044.111.11.6.112.1.2Columnpm100gfmuxdPerfTelecomInputClientPast24StatHistoryInvCvPort1read-onlycurrentPrevious 24-hours EBC counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.111.11.6.112.1.3Columnpm100gfmuxdPerfTelecomInputClientPast24StatHistoryCvValuePort1read-onlycurrentPrevious 24-hours EBC counter :This OID gives the previous 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.111.11.6.112.1.4Columnpm100gfmuxdPerfTelecomInputClientPast24StatHistoryInvEsPort1read-onlycurrentPrevious 24-hours ES counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.112.1.5Columnpm100gfmuxdPerfTelecomInputClientPast24StatHistoryEsValuePort1read-onlycurrentPrevious 24-hours ES counter :This OID gives the previous 24-hours Errored Second counter value
1.3.6.1.4.1.20044.111.11.6.112.1.6Columnpm100gfmuxdPerfTelecomInputClientPast24StatHistoryInvSesPort1read-onlycurrentPrevious 24-hours SES counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.112.1.7Columnpm100gfmuxdPerfTelecomInputClientPast24StatHistorySesValuePort1read-onlycurrentPrevious 24-hours SES counter :This OID gives the previous 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.111.11.6.112.1.8Columnpm100gfmuxdPerfTelecomInputClientPast24StatHistoryInvSefsPort1read-onlycurrentPrevious 24-hours SEFS counter inv. :This OID indicates that the previous 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.112.1.9Columnpm100gfmuxdPerfTelecomInputClientPast24StatHistorySefsValuePort1read-onlycurrentPrevious 24-hours SEFS counter :This OID gives the previous 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.111.11.6.112.1.10Columnpm100gfmuxdPerfTelecomInputClientPast24StatHistoryInvUasPort1read-onlycurrentPrevious 24-hours UAS counter inv. :This OID indicates that the previous 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.112.1.11Columnpm100gfmuxdPerfTelecomInputClientPast24StatHistoryUasValuePort1read-onlycurrentPrevious 24-hours UAS counter :This OID gives the previous 24-hours UnAvailable Second counter value
1.3.6.1.4.1.20044.111.11.6.144Tablepm100gfmuxdPerfTelecomOutputClientCurrent15StatTablenot-accessiblecurrentList of pm100gfmuxdPerfTelecomOutputClientCurrent15Stat Article
1.3.6.1.4.1.20044.111.11.6.144.1Rowpm100gfmuxdPerfTelecomOutputClientCurrent15StatEntrynot-accessiblecurrentRow definition for the pm100gfmuxdPerfTelecomOutputClientCurrent15Stat table
1.3.6.1.4.1.20044.111.11.6.144.1.1Columnpm100gfmuxdPerfTelecomOutputClientCurrent15StatIndexread-onlycurrentIndex definition for the pm100gfmuxdPerfTelecomOutputClientCurrent15Stat table
1.3.6.1.4.1.20044.111.11.6.144.1.2Columnpm100gfmuxdPerfTelecomOutputClientCurrent15StatInvCvPortnread-onlycurrentCurrent 15-min EBC counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.111.11.6.144.1.3Columnpm100gfmuxdPerfTelecomOutputClientCurrent15StatCvValuePortnread-onlycurrentCurrent 15-min EBC counter :This OID gives the current 15-min Coding Violation counter value
1.3.6.1.4.1.20044.111.11.6.144.1.4Columnpm100gfmuxdPerfTelecomOutputClientCurrent15StatInvEsPortnread-onlycurrentCurrent 15-min ES counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.144.1.5Columnpm100gfmuxdPerfTelecomOutputClientCurrent15StatEsValuePortnread-onlycurrentCurrent 15-min ES counter :This OID gives the current 15-min Errored Second counter value
1.3.6.1.4.1.20044.111.11.6.144.1.6Columnpm100gfmuxdPerfTelecomOutputClientCurrent15StatInvSesPortnread-onlycurrentCurrent 15-min SES counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.144.1.7Columnpm100gfmuxdPerfTelecomOutputClientCurrent15StatSesValuePortnread-onlycurrentCurrent 15-min SES counter :This OID gives the current 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.111.11.6.144.1.8Columnpm100gfmuxdPerfTelecomOutputClientCurrent15StatInvSefsPortnread-onlycurrentCurrent 15-min SEFS counter inv. :This OID indicates that the current 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.144.1.9Columnpm100gfmuxdPerfTelecomOutputClientCurrent15StatSefsValuePortnread-onlycurrentCurrent 15-min SEFS counter :This OID gives the current 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.111.11.6.144.1.10Columnpm100gfmuxdPerfTelecomOutputClientCurrent15StatInvUasPortnread-onlycurrentCurrent 15-min UAS counter inv. :This OID indicates that the current 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.144.1.11Columnpm100gfmuxdPerfTelecomOutputClientCurrent15StatUasValuePortnread-onlycurrentCurrent 15-min UAS counter :This OID gives the current 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.111.11.6.176Tablepm100gfmuxdPerfTelecomOutputClientPast15StatHistoryPort1Tablenot-accessiblecurrentList of pm100gfmuxdPerfTelecomOutputClientPast15StatHistory Article
1.3.6.1.4.1.20044.111.11.6.176.1Rowpm100gfmuxdPerfTelecomOutputClientPast15StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pm100gfmuxdPerfTelecomOutputClientPast15StatHistory table
1.3.6.1.4.1.20044.111.11.6.176.1.1Columnpm100gfmuxdPerfTelecomOutputClientPast15StatHistoryPort1Indexread-onlycurrentIndex definition for the pm100gfmuxdPerfTelecomOutputClientPast15StatHistory table
1.3.6.1.4.1.20044.111.11.6.176.1.2Columnpm100gfmuxdPerfTelecomOutputClientPast15StatHistoryInvCvPort1read-onlycurrentPrevious 15-min EBC counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.111.11.6.176.1.3Columnpm100gfmuxdPerfTelecomOutputClientPast15StatHistoryCvValuePort1read-onlycurrentPrevious 15-min EBC counter :This OID gives the previous 15-min Coding Violation counter value
1.3.6.1.4.1.20044.111.11.6.176.1.4Columnpm100gfmuxdPerfTelecomOutputClientPast15StatHistoryInvEsPort1read-onlycurrentPrevious 15-min ES counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.176.1.5Columnpm100gfmuxdPerfTelecomOutputClientPast15StatHistoryEsValuePort1read-onlycurrentPrevious 15-min ES counter :This OID gives the previous 15-min Errored Second counter value
1.3.6.1.4.1.20044.111.11.6.176.1.6Columnpm100gfmuxdPerfTelecomOutputClientPast15StatHistoryInvSesPort1read-onlycurrentPrevious 15-min SES counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.176.1.7Columnpm100gfmuxdPerfTelecomOutputClientPast15StatHistorySesValuePort1read-onlycurrentPrevious 15-min SES counter :This OID gives the previous 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.111.11.6.176.1.8Columnpm100gfmuxdPerfTelecomOutputClientPast15StatHistoryInvSefsPort1read-onlycurrentPrevious 15-min SEFS counter inv. :This OID indicates that the previous 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.176.1.9Columnpm100gfmuxdPerfTelecomOutputClientPast15StatHistorySefsValuePort1read-onlycurrentPrevious 15-min SEFS counter :This OID gives the previous 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.111.11.6.176.1.10Columnpm100gfmuxdPerfTelecomOutputClientPast15StatHistoryInvUasPort1read-onlycurrentPrevious 15-min UAS counter inv. :This OID indicates that the previous 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.176.1.11Columnpm100gfmuxdPerfTelecomOutputClientPast15StatHistoryUasValuePort1read-onlycurrentPrevious 15-min UAS counter :This OID gives the previous 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.111.11.6.208Tablepm100gfmuxdPerfTelecomOutputClientCurrent24StatTablenot-accessiblecurrentList of pm100gfmuxdPerfTelecomOutputClientCurrent24Stat Article
1.3.6.1.4.1.20044.111.11.6.208.1Rowpm100gfmuxdPerfTelecomOutputClientCurrent24StatEntrynot-accessiblecurrentRow definition for the pm100gfmuxdPerfTelecomOutputClientCurrent24Stat table
1.3.6.1.4.1.20044.111.11.6.208.1.1Columnpm100gfmuxdPerfTelecomOutputClientCurrent24StatIndexread-onlycurrentIndex definition for the pm100gfmuxdPerfTelecomOutputClientCurrent24Stat table
1.3.6.1.4.1.20044.111.11.6.208.1.2Columnpm100gfmuxdPerfTelecomOutputClientCurrent24StatInvCvPortnread-onlycurrentCurrent 24-hours EBC counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.111.11.6.208.1.3Columnpm100gfmuxdPerfTelecomOutputClientCurrent24StatCvValuePortnread-onlycurrentCurrent 24-hours EBC counter :This OID gives the current 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.111.11.6.208.1.4Columnpm100gfmuxdPerfTelecomOutputClientCurrent24StatInvEsPortnread-onlycurrentCurrent 24-hours ES counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.208.1.5Columnpm100gfmuxdPerfTelecomOutputClientCurrent24StatEsValuePortnread-onlycurrentCurrent 24-hours ES counter :This OID gives the current 24-hours Errored Second counter value
1.3.6.1.4.1.20044.111.11.6.208.1.6Columnpm100gfmuxdPerfTelecomOutputClientCurrent24StatInvSesPortnread-onlycurrentCurrent 24-hours SES counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.208.1.7Columnpm100gfmuxdPerfTelecomOutputClientCurrent24StatSesValuePortnread-onlycurrentCurrent 24-hours SES counter :This OID gives the current 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.111.11.6.208.1.8Columnpm100gfmuxdPerfTelecomOutputClientCurrent24StatInvSefsPortnread-onlycurrentCurrent 24-hours SEFS counter inv. :This OID indicates that the current 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.208.1.9Columnpm100gfmuxdPerfTelecomOutputClientCurrent24StatSefsValuePortnread-onlycurrentCurrent 24-hours SEFS counter :This OID gives the current 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.111.11.6.208.1.10Columnpm100gfmuxdPerfTelecomOutputClientCurrent24StatInvUasPortnread-onlycurrentCurrent 24-hours UAS counter inv. :This OID indicates that the current 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.208.1.11Columnpm100gfmuxdPerfTelecomOutputClientCurrent24StatUasValuePortnread-onlycurrentCurrent 24-hours UAS counter :This OID gives the current 24-hours UnAvailable Second counter value
1.3.6.1.4.1.20044.111.11.6.240Tablepm100gfmuxdPerfTelecomOutputClientPast24StatHistoryPort1Tablenot-accessiblecurrentList of pm100gfmuxdPerfTelecomOutputClientPast24StatHistory Article
1.3.6.1.4.1.20044.111.11.6.240.1Rowpm100gfmuxdPerfTelecomOutputClientPast24StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pm100gfmuxdPerfTelecomOutputClientPast24StatHistory table
1.3.6.1.4.1.20044.111.11.6.240.1.1Columnpm100gfmuxdPerfTelecomOutputClientPast24StatHistoryPort1Indexread-onlycurrentIndex definition for the pm100gfmuxdPerfTelecomOutputClientPast24StatHistory table
1.3.6.1.4.1.20044.111.11.6.240.1.2Columnpm100gfmuxdPerfTelecomOutputClientPast24StatHistoryInvCvPort1read-onlycurrentPrevious 24-hours EBC counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.111.11.6.240.1.3Columnpm100gfmuxdPerfTelecomOutputClientPast24StatHistoryCvValuePort1read-onlycurrentPrevious 24-hours EBC counter :This OID gives the previous 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.111.11.6.240.1.4Columnpm100gfmuxdPerfTelecomOutputClientPast24StatHistoryInvEsPort1read-onlycurrentPrevious 24-hours ES counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.240.1.5Columnpm100gfmuxdPerfTelecomOutputClientPast24StatHistoryEsValuePort1read-onlycurrentPrevious 24-hours ES counter :This OID gives the previous 24-hours Errored Second counter value
1.3.6.1.4.1.20044.111.11.6.240.1.6Columnpm100gfmuxdPerfTelecomOutputClientPast24StatHistoryInvSesPort1read-onlycurrentPrevious 24-hours SES counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.240.1.7Columnpm100gfmuxdPerfTelecomOutputClientPast24StatHistorySesValuePort1read-onlycurrentPrevious 24-hours SES counter :This OID gives the previous 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.111.11.6.240.1.8Columnpm100gfmuxdPerfTelecomOutputClientPast24StatHistoryInvSefsPort1read-onlycurrentPrevious 24-hours SEFS counter inv. :This OID indicates that the previous 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.240.1.9Columnpm100gfmuxdPerfTelecomOutputClientPast24StatHistorySefsValuePort1read-onlycurrentPrevious 24-hours SEFS counter :This OID gives the previous 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.111.11.6.240.1.10Columnpm100gfmuxdPerfTelecomOutputClientPast24StatHistoryInvUasPort1read-onlycurrentPrevious 24-hours UAS counter inv. :This OID indicates that the previous 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.111.11.6.240.1.11Columnpm100gfmuxdPerfTelecomOutputClientPast24StatHistoryUasValuePort1read-onlycurrentPrevious 24-hours UAS counter :This OID gives the previous 24-hours UnAvailable Second counter value
1.3.6.1.4.1.20044.111.11.6.848Tablepm100gfmuxdPerfDatacomClientCurrent15StatTablenot-accessiblecurrentList of pm100gfmuxdPerfDatacomClientCurrent15Stat Article
1.3.6.1.4.1.20044.111.11.6.848.1Rowpm100gfmuxdPerfDatacomClientCurrent15StatEntrynot-accessiblecurrentRow definition for the pm100gfmuxdPerfDatacomClientCurrent15Stat table
1.3.6.1.4.1.20044.111.11.6.848.1.1Columnpm100gfmuxdPerfDatacomClientCurrent15StatIndexread-onlycurrentIndex definition for the pm100gfmuxdPerfDatacomClientCurrent15Stat table
1.3.6.1.4.1.20044.111.11.6.848.1.4Columnpm100gfmuxdperfdatacomclientCurrent15StatInCrcCountInvPortnread-onlycurrentClient Current 15-min Input CRC counter inv. :This OID indicates that the current 15-min Input CRC counter is invalid
1.3.6.1.4.1.20044.111.11.6.848.1.5Columnpm100gfmuxdperfdatacomclientCurrent15StatInCrcCountPortnread-onlycurrentClient Current 15-min Input CRC counter :This OID gives the current 15-min Input CRC counter value
1.3.6.1.4.1.20044.111.11.6.848.1.6Columnpm100gfmuxdperfdatacomclientCurrent15StatInPacketCountInvPortnread-onlycurrentClient Current 15-min Input Packet counter inv. :This OID indicates that the current 15-min Input Packet counter is invalid
1.3.6.1.4.1.20044.111.11.6.848.1.7Columnpm100gfmuxdperfdatacomclientCurrent15StatInPacketCountPortnread-onlycurrentClient Current 15-min Input Packet counter :This OID gives the current 15-min Input Packet counter value
1.3.6.1.4.1.20044.111.11.6.848.1.28Columnpm100gfmuxdperfdatacomclientCurrent15StatOutCrcCountInvPortnread-onlycurrentClient Current 15-min Output CRC counter inv. :This OID indicates that the current 15-min Output CRC counter is invalid
1.3.6.1.4.1.20044.111.11.6.848.1.29Columnpm100gfmuxdperfdatacomclientCurrent15StatOutCrcCountPortnread-onlycurrentClient Current 15-min Output CRC counter :This OID gives the current 15-min Output CRC counter value
1.3.6.1.4.1.20044.111.11.6.848.1.30Columnpm100gfmuxdperfdatacomclientCurrent15StatOutPacketCountInvPortnread-onlycurrentClient Current 15-min Output Packet counter inv. :This OID indicates that the current 15-min Output Packets counter is invalid
1.3.6.1.4.1.20044.111.11.6.848.1.31Columnpm100gfmuxdperfdatacomclientCurrent15StatOutPacketCountPortnread-onlycurrentClient Current 15-min Output Packet counter :This OID gives the current 15-min Output Packets counter value
1.3.6.1.4.1.20044.111.11.6.880Tablepm100gfmuxdPerfDatacomClientPast15StatHistoryPort1Tablenot-accessiblecurrentList of pm100gfmuxdPerfDatacomClientPast15StatHistory Article
1.3.6.1.4.1.20044.111.11.6.880.1Rowpm100gfmuxdPerfDatacomClientPast15StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pm100gfmuxdPerfDatacomClientPast15StatHistory table
1.3.6.1.4.1.20044.111.11.6.880.1.1Columnpm100gfmuxdPerfDatacomClientPast15StatHistoryPort1Indexread-onlycurrentIndex definition for the pm100gfmuxdPerfDatacomClientPast15StatHistory table
1.3.6.1.4.1.20044.111.11.6.880.1.4Columnpm100gfmuxdperfdatacomclientPast15StatInCrcCountInvPort1read-onlycurrentClient Past 15-min Input CRC counter inv. :This OID indicates that the past 15-min Input CRC counter is invalid
1.3.6.1.4.1.20044.111.11.6.880.1.5Columnpm100gfmuxdperfdatacomclientPast15StatInCrcCountPort1read-onlycurrentClient Past 15-min Input CRC counter :This OID gives the past 15-min Input CRC counter value
1.3.6.1.4.1.20044.111.11.6.880.1.6Columnpm100gfmuxdperfdatacomclientPast15StatInPacketCountInvPort1read-onlycurrentClient Past 15-min Input Packet counter inv. :This OID indicates that the past 15-min Input Packet counter is invalid
1.3.6.1.4.1.20044.111.11.6.880.1.7Columnpm100gfmuxdperfdatacomclientPast15StatInPacketCountPort1read-onlycurrentClient Past 15-min Input Packet counter :This OID gives the past 15-min Input Packet counter value
1.3.6.1.4.1.20044.111.11.6.880.1.28Columnpm100gfmuxdperfdatacomclientPast15StatOutCrcCountInvPort1read-onlycurrentClient Past 15-min Output CRC counter inv. :This OID indicates that the past 15-min Output CRC counter is invalid
1.3.6.1.4.1.20044.111.11.6.880.1.29Columnpm100gfmuxdperfdatacomclientPast15StatOutCrcCountPort1read-onlycurrentClient Past 15-min Output CRC counter :This OID gives the past 15-min Output CRC counter value
1.3.6.1.4.1.20044.111.11.6.880.1.30Columnpm100gfmuxdperfdatacomclientPast15StatOutPacketCountInvPort1read-onlycurrentClient Past 15-min Output Packet counter inv. :This OID indicates that the past 15-min Output Packets counter is invalid
1.3.6.1.4.1.20044.111.11.6.880.1.31Columnpm100gfmuxdperfdatacomclientPast15StatOutPacketCountPort1read-onlycurrentClient Past 15-min Output Packet counter :This OID gives the past 15-min Output Packets counter value
1.3.6.1.4.1.20044.111.11.6.912Tablepm100gfmuxdPerfDatacomClientCurrent24StatTablenot-accessiblecurrentList of pm100gfmuxdPerfDatacomClientCurrent24Stat Article
1.3.6.1.4.1.20044.111.11.6.912.1Rowpm100gfmuxdPerfDatacomClientCurrent24StatEntrynot-accessiblecurrentRow definition for the pm100gfmuxdPerfDatacomClientCurrent24Stat table
1.3.6.1.4.1.20044.111.11.6.912.1.1Columnpm100gfmuxdPerfDatacomClientCurrent24StatIndexread-onlycurrentIndex definition for the pm100gfmuxdPerfDatacomClientCurrent24Stat table
1.3.6.1.4.1.20044.111.11.6.912.1.4Columnpm100gfmuxdperfdatacomclientCurrent24StatInCrcCountInvPortnread-onlycurrentClient Current 24-hours Input CRC counter inv. :This OID indicates that the current 24-hours Input CRC counter is invalid
1.3.6.1.4.1.20044.111.11.6.912.1.5Columnpm100gfmuxdperfdatacomclientCurrent24StatInCrcCountPortnread-onlycurrentClient Current 24-hours Input CRC counter :This OID gives the current 24-hours Input CRC counter value
1.3.6.1.4.1.20044.111.11.6.912.1.6Columnpm100gfmuxdperfdatacomclientCurrent24StatInPacketCountInvPortnread-onlycurrentClient Current 24-hours Input Packet counter inv. :This OID indicates that the current 24-hours Input Packet counter is invalid
1.3.6.1.4.1.20044.111.11.6.912.1.7Columnpm100gfmuxdperfdatacomclientCurrent24StatInPacketCountPortnread-onlycurrentClient Current 24-hours Input Packet counter :This OID gives the current 24-hours Input Packet counter value
1.3.6.1.4.1.20044.111.11.6.912.1.28Columnpm100gfmuxdperfdatacomclientCurrent24StatOutCrcCountInvPortnread-onlycurrentClient Current 24-hours Output CRC counter inv. :This OID indicates that the current 24-hours Output CRC counter is invalid
1.3.6.1.4.1.20044.111.11.6.912.1.29Columnpm100gfmuxdperfdatacomclientCurrent24StatOutCrcCountPortnread-onlycurrentClient Current 24-hours Output CRC counter :This OID gives the current 24-hours Output CRC counter value
1.3.6.1.4.1.20044.111.11.6.912.1.30Columnpm100gfmuxdperfdatacomclientCurrent24StatOutPacketCountInvPortnread-onlycurrentClient Current 24-hours Output Packet counter inv. :This OID indicates that the current 24-hours Output Packets counter is invalid
1.3.6.1.4.1.20044.111.11.6.912.1.31Columnpm100gfmuxdperfdatacomclientCurrent24StatOutPacketCountPortnread-onlycurrentClient Current 24-hours Output Packet counter :This OID gives the current 24-hours Output Packets counter value
1.3.6.1.4.1.20044.111.11.6.944Tablepm100gfmuxdPerfDatacomClientPast24StatHistoryPort1Tablenot-accessiblecurrentList of pm100gfmuxdPerfDatacomClientPast24StatHistory Article
1.3.6.1.4.1.20044.111.11.6.944.1Rowpm100gfmuxdPerfDatacomClientPast24StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pm100gfmuxdPerfDatacomClientPast24StatHistory table
1.3.6.1.4.1.20044.111.11.6.944.1.1Columnpm100gfmuxdPerfDatacomClientPast24StatHistoryPort1Indexread-onlycurrentIndex definition for the pm100gfmuxdPerfDatacomClientPast24StatHistory table
1.3.6.1.4.1.20044.111.11.6.944.1.4Columnpm100gfmuxdperfdatacomclientPast24StatInCrcCountInvPort1read-onlycurrentClient Past 24-hours Input CRC counter inv. :This OID indicates that the past 24-hours Input CRC counter is invalid
1.3.6.1.4.1.20044.111.11.6.944.1.5Columnpm100gfmuxdperfdatacomclientPast24StatInCrcCountPort1read-onlycurrentClient Past 24-hours Input CRC counter :This OID gives the past 24-hours Input CRC counter value
1.3.6.1.4.1.20044.111.11.6.944.1.6Columnpm100gfmuxdperfdatacomclientPast24StatInPacketCountInvPort1read-onlycurrentClient Past 24-hours Input Packet counter inv. :This OID indicates that the past 24-hours Input Packet counter is invalid
1.3.6.1.4.1.20044.111.11.6.944.1.7Columnpm100gfmuxdperfdatacomclientPast24StatInPacketCountPort1read-onlycurrentClient Past 24-hours Input Packet counter :This OID gives the past 24-hours Input Packet counter value
1.3.6.1.4.1.20044.111.11.6.944.1.28Columnpm100gfmuxdperfdatacomclientPast24StatOutCrcCountInvPort1read-onlycurrentClient Past 24-hours Output CRC counter inv. :This OID indicates that the past 24-hours Output CRC counter is invalid
1.3.6.1.4.1.20044.111.11.6.944.1.29Columnpm100gfmuxdperfdatacomclientPast24StatOutCrcCountPort1read-onlycurrentClient Past 24-hours Output CRC counter :This OID gives the past 24-hours Output CRC counter value
1.3.6.1.4.1.20044.111.11.6.944.1.30Columnpm100gfmuxdperfdatacomclientPast24StatOutPacketCountInvPort1read-onlycurrentClient Past 24-hours Output Packet counter inv. :This OID indicates that the past 24-hours Output Packets counter is invalid
1.3.6.1.4.1.20044.111.11.6.944.1.31Columnpm100gfmuxdperfdatacomclientPast24StatOutPacketCountPort1read-onlycurrentClient Past 24-hours Output Packet counter :This OID gives the past 24-hours Output Packets counter value
1.3.6.1.4.1.20044.111.11.7Nodepm100gfmuxdMonPerfLine
1.3.6.1.4.1.20044.111.11.7.336Tablepm100gfmuxdPerfTelecomLinePostFecCurrent15StatTablenot-accessiblecurrentList of pm100gfmuxdPerfTelecomLinePostFecCurrent15Stat Article
1.3.6.1.4.1.20044.111.11.7.336.1Rowpm100gfmuxdPerfTelecomLinePostFecCurrent15StatEntrynot-accessiblecurrentRow definition for the pm100gfmuxdPerfTelecomLinePostFecCurrent15Stat table
1.3.6.1.4.1.20044.111.11.7.336.1.1Columnpm100gfmuxdPerfTelecomLinePostFecCurrent15StatIndexread-onlycurrentIndex definition for the pm100gfmuxdPerfTelecomLinePostFecCurrent15Stat table
1.3.6.1.4.1.20044.111.11.7.336.1.2Columnpm100gfmuxdPerfTelecomLinePostFecCurrent15StatInvCvPortnread-onlycurrentCurrent 15-min EBC counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.111.11.7.336.1.3Columnpm100gfmuxdPerfTelecomLinePostFecCurrent15StatCvValuePortnread-onlycurrentCurrent 15-min EBC counter :This OID gives the current 15-min Coding Violation counter value
1.3.6.1.4.1.20044.111.11.7.336.1.4Columnpm100gfmuxdPerfTelecomLinePostFecCurrent15StatInvEsPortnread-onlycurrentCurrent 15-min ES counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.7.336.1.5Columnpm100gfmuxdPerfTelecomLinePostFecCurrent15StatEsValuePortnread-onlycurrentCurrent 15-min ES counter :This OID gives the current 15-min Errored Second counter value
1.3.6.1.4.1.20044.111.11.7.336.1.6Columnpm100gfmuxdPerfTelecomLinePostFecCurrent15StatInvSesPortnread-onlycurrentCurrent 15-min SES counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.7.336.1.7Columnpm100gfmuxdPerfTelecomLinePostFecCurrent15StatSesValuePortnread-onlycurrentCurrent 15-min SES counter :This OID gives the current 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.111.11.7.336.1.8Columnpm100gfmuxdPerfTelecomLinePostFecCurrent15StatInvSefsPortnread-onlycurrentCurrent 15-min SEFS counter inv. :This OID indicates that the current 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.111.11.7.336.1.9Columnpm100gfmuxdPerfTelecomLinePostFecCurrent15StatSefsValuePortnread-onlycurrentCurrent 15-min SEFS counter :This OID gives the current 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.111.11.7.336.1.10Columnpm100gfmuxdPerfTelecomLinePostFecCurrent15StatInvUasPortnread-onlycurrentCurrent 15-min UAS counter inv. :This OID indicates that the current 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.111.11.7.336.1.11Columnpm100gfmuxdPerfTelecomLinePostFecCurrent15StatUasValuePortnread-onlycurrentCurrent 15-min UAS counter :This OID gives the current 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.111.11.7.337Tablepm100gfmuxdPerfTelecomLinePostFecPast15StatHistoryPort1Tablenot-accessiblecurrentList of pm100gfmuxdPerfTelecomLinePostFecPast15StatHistory Article
1.3.6.1.4.1.20044.111.11.7.337.1Rowpm100gfmuxdPerfTelecomLinePostFecPast15StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pm100gfmuxdPerfTelecomLinePostFecPast15StatHistory table
1.3.6.1.4.1.20044.111.11.7.337.1.1Columnpm100gfmuxdPerfTelecomLinePostFecPast15StatHistoryPort1Indexread-onlycurrentIndex definition for the pm100gfmuxdPerfTelecomLinePostFecPast15StatHistory table
1.3.6.1.4.1.20044.111.11.7.337.1.2Columnpm100gfmuxdPerfTelecomLinePostFecPast15StatHistoryInvCvPort1read-onlycurrentPrevious 15-min EBC counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.111.11.7.337.1.3Columnpm100gfmuxdPerfTelecomLinePostFecPast15StatHistoryCvValuePort1read-onlycurrentPrevious 15-min EBC counter :This OID gives the previous 15-min Coding Violation counter value
1.3.6.1.4.1.20044.111.11.7.337.1.4Columnpm100gfmuxdPerfTelecomLinePostFecPast15StatHistoryInvEsPort1read-onlycurrentPrevious 15-min ES counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.7.337.1.5Columnpm100gfmuxdPerfTelecomLinePostFecPast15StatHistoryEsValuePort1read-onlycurrentPrevious 15-min ES counter :This OID gives the previous 15-min Errored Second counter value
1.3.6.1.4.1.20044.111.11.7.337.1.6Columnpm100gfmuxdPerfTelecomLinePostFecPast15StatHistoryInvSesPort1read-onlycurrentPrevious 15-min SES counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.7.337.1.7Columnpm100gfmuxdPerfTelecomLinePostFecPast15StatHistorySesValuePort1read-onlycurrentPrevious 15-min SES counter :This OID gives the previous 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.111.11.7.337.1.8Columnpm100gfmuxdPerfTelecomLinePostFecPast15StatHistoryInvSefsPort1read-onlycurrentPrevious 15-min SEFS counter inv. :This OID indicates that the previous 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.111.11.7.337.1.9Columnpm100gfmuxdPerfTelecomLinePostFecPast15StatHistorySefsValuePort1read-onlycurrentPrevious 15-min SEFS counter :This OID gives the previous 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.111.11.7.337.1.10Columnpm100gfmuxdPerfTelecomLinePostFecPast15StatHistoryInvUasPort1read-onlycurrentPrevious 15-min UAS counter inv. :This OID indicates that the previous 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.111.11.7.337.1.11Columnpm100gfmuxdPerfTelecomLinePostFecPast15StatHistoryUasValuePort1read-onlycurrentPrevious 15-min UAS counter :This OID gives the previous 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.111.11.7.338Tablepm100gfmuxdPerfTelecomLinePostFecCurrent24StatTablenot-accessiblecurrentList of pm100gfmuxdPerfTelecomLinePostFecCurrent24Stat Article
1.3.6.1.4.1.20044.111.11.7.338.1Rowpm100gfmuxdPerfTelecomLinePostFecCurrent24StatEntrynot-accessiblecurrentRow definition for the pm100gfmuxdPerfTelecomLinePostFecCurrent24Stat table
1.3.6.1.4.1.20044.111.11.7.338.1.1Columnpm100gfmuxdPerfTelecomLinePostFecCurrent24StatIndexread-onlycurrentIndex definition for the pm100gfmuxdPerfTelecomLinePostFecCurrent24Stat table
1.3.6.1.4.1.20044.111.11.7.338.1.2Columnpm100gfmuxdPerfTelecomLinePostFecCurrent24StatInvCvPortnread-onlycurrentCurrent 24-hours EBC counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.111.11.7.338.1.3Columnpm100gfmuxdPerfTelecomLinePostFecCurrent24StatCvValuePortnread-onlycurrentCurrent 24-hours EBC counter :This OID gives the current 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.111.11.7.338.1.4Columnpm100gfmuxdPerfTelecomLinePostFecCurrent24StatInvEsPortnread-onlycurrentCurrent 24-hours ES counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.7.338.1.5Columnpm100gfmuxdPerfTelecomLinePostFecCurrent24StatEsValuePortnread-onlycurrentCurrent 24-hours ES counter :This OID gives the current 24-hours Errored Second counter value
1.3.6.1.4.1.20044.111.11.7.338.1.6Columnpm100gfmuxdPerfTelecomLinePostFecCurrent24StatInvSesPortnread-onlycurrentCurrent 24-hours SES counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.7.338.1.7Columnpm100gfmuxdPerfTelecomLinePostFecCurrent24StatSesValuePortnread-onlycurrentCurrent 24-hours SES counter :This OID gives the current 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.111.11.7.338.1.8Columnpm100gfmuxdPerfTelecomLinePostFecCurrent24StatInvSefsPortnread-onlycurrentCurrent 24-hours SEFS counter inv. :This OID indicates that the current 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.111.11.7.338.1.9Columnpm100gfmuxdPerfTelecomLinePostFecCurrent24StatSefsValuePortnread-onlycurrentCurrent 24-hours SEFS counter :This OID gives the current 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.111.11.7.338.1.10Columnpm100gfmuxdPerfTelecomLinePostFecCurrent24StatInvUasPortnread-onlycurrentCurrent 24-hours UAS counter inv. :This OID indicates that the current 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.111.11.7.338.1.11Columnpm100gfmuxdPerfTelecomLinePostFecCurrent24StatUasValuePortnread-onlycurrentCurrent 24-hours UAS counter :This OID gives the current 24-hours UnAvailable Second counter value
1.3.6.1.4.1.20044.111.11.7.339Tablepm100gfmuxdPerfTelecomLinePostFecPast24StatHistoryPort1Tablenot-accessiblecurrentList of pm100gfmuxdPerfTelecomLinePostFecPast24StatHistory Article
1.3.6.1.4.1.20044.111.11.7.339.1Rowpm100gfmuxdPerfTelecomLinePostFecPast24StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pm100gfmuxdPerfTelecomLinePostFecPast24StatHistory table
1.3.6.1.4.1.20044.111.11.7.339.1.1Columnpm100gfmuxdPerfTelecomLinePostFecPast24StatHistoryPort1Indexread-onlycurrentIndex definition for the pm100gfmuxdPerfTelecomLinePostFecPast24StatHistory table
1.3.6.1.4.1.20044.111.11.7.339.1.2Columnpm100gfmuxdPerfTelecomLinePostFecPast24StatHistoryInvCvPort1read-onlycurrentPrevious 24-hours EBC counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.111.11.7.339.1.3Columnpm100gfmuxdPerfTelecomLinePostFecPast24StatHistoryCvValuePort1read-onlycurrentPrevious 24-hours EBC counter :This OID gives the previous 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.111.11.7.339.1.4Columnpm100gfmuxdPerfTelecomLinePostFecPast24StatHistoryInvEsPort1read-onlycurrentPrevious 24-hours ES counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.7.339.1.5Columnpm100gfmuxdPerfTelecomLinePostFecPast24StatHistoryEsValuePort1read-onlycurrentPrevious 24-hours ES counter :This OID gives the previous 24-hours Errored Second counter value
1.3.6.1.4.1.20044.111.11.7.339.1.6Columnpm100gfmuxdPerfTelecomLinePostFecPast24StatHistoryInvSesPort1read-onlycurrentPrevious 24-hours SES counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.7.339.1.7Columnpm100gfmuxdPerfTelecomLinePostFecPast24StatHistorySesValuePort1read-onlycurrentPrevious 24-hours SES counter :This OID gives the previous 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.111.11.7.339.1.8Columnpm100gfmuxdPerfTelecomLinePostFecPast24StatHistoryInvSefsPort1read-onlycurrentPrevious 24-hours SEFS counter inv. :This OID indicates that the previous 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.111.11.7.339.1.9Columnpm100gfmuxdPerfTelecomLinePostFecPast24StatHistorySefsValuePort1read-onlycurrentPrevious 24-hours SEFS counter :This OID gives the previous 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.111.11.7.339.1.10Columnpm100gfmuxdPerfTelecomLinePostFecPast24StatHistoryInvUasPort1read-onlycurrentPrevious 24-hours UAS counter inv. :This OID indicates that the previous 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.111.11.7.339.1.11Columnpm100gfmuxdPerfTelecomLinePostFecPast24StatHistoryUasValuePort1read-onlycurrentPrevious 24-hours UAS counter :This OID gives the previous 24-hours UnAvailable Second counter value
1.3.6.1.4.1.20044.111.11.7.352Tablepm100gfmuxdPerfTelecomBerLinePreFecCurrent15StatTablenot-accessiblecurrentList of pm100gfmuxdPerfTelecomBerLinePreFecCurrent15Stat Article
1.3.6.1.4.1.20044.111.11.7.352.1Rowpm100gfmuxdPerfTelecomBerLinePreFecCurrent15StatEntrynot-accessiblecurrentRow definition for the pm100gfmuxdPerfTelecomBerLinePreFecCurrent15Stat table
1.3.6.1.4.1.20044.111.11.7.352.1.1Columnpm100gfmuxdPerfTelecomBerLinePreFecCurrent15StatIndexread-onlycurrentIndex definition for the pm100gfmuxdPerfTelecomBerLinePreFecCurrent15Stat table
1.3.6.1.4.1.20044.111.11.7.352.1.2Columnpm100gfmuxdPerfTelecomBerLinePreFecCurrent15StatInvBerPortnread-onlycurrentCurrent 15-min BER counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.111.11.7.352.1.3Columnpm100gfmuxdPerfTelecomBerLinePreFecCurrent15StatBerValuePortnread-onlycurrentCurrent 15-min BER counter :This OID gives the current 15-min Coding Violation counter value
1.3.6.1.4.1.20044.111.11.7.352.1.4Columnpm100gfmuxdPerfTelecomBerLinePreFecCurrent15StatInvMinBerPortnread-onlycurrentCurrent 15-min MinBER counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.7.352.1.5Columnpm100gfmuxdPerfTelecomBerLinePreFecCurrent15StatMinBerValuePortnread-onlycurrentCurrent 15-min MinBER counter :This OID gives the current 15-min Errored Second counter value
1.3.6.1.4.1.20044.111.11.7.352.1.6Columnpm100gfmuxdPerfTelecomBerLinePreFecCurrent15StatInvMaxBerPortnread-onlycurrentCurrent 15-min MaxBER counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.7.352.1.7Columnpm100gfmuxdPerfTelecomBerLinePreFecCurrent15StatMaxBerValuePortnread-onlycurrentCurrent 15-min MaxBER counter :This OID gives the current 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.111.11.7.353Tablepm100gfmuxdPerfTelecomBerLinePreFecPast15StatHistoryPort1Tablenot-accessiblecurrentList of pm100gfmuxdPerfTelecomBerLinePreFecPast15StatHistory Article
1.3.6.1.4.1.20044.111.11.7.353.1Rowpm100gfmuxdPerfTelecomBerLinePreFecPast15StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pm100gfmuxdPerfTelecomBerLinePreFecPast15StatHistory table
1.3.6.1.4.1.20044.111.11.7.353.1.1Columnpm100gfmuxdPerfTelecomBerLinePreFecPast15StatHistoryPort1Indexread-onlycurrentIndex definition for the pm100gfmuxdPerfTelecomBerLinePreFecPast15StatHistory table
1.3.6.1.4.1.20044.111.11.7.353.1.2Columnpm100gfmuxdPerfTelecomBerLinePreFecPast15StatHistoryInvBerPort1read-onlycurrentPrevious 15-min BER counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.111.11.7.353.1.3Columnpm100gfmuxdPerfTelecomBerLinePreFecPast15StatHistoryBerValuePort1read-onlycurrentPrevious 15-min BER counter :This OID gives the previous 15-min Coding Violation counter value
1.3.6.1.4.1.20044.111.11.7.353.1.4Columnpm100gfmuxdPerfTelecomBerLinePreFecPast15StatHistoryInvMinBerPort1read-onlycurrentPrevious 15-min MinBER counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.7.353.1.5Columnpm100gfmuxdPerfTelecomBerLinePreFecPast15StatHistoryMinBerValuePort1read-onlycurrentPrevious 15-min MinBER counter :This OID gives the previous 15-min Errored Second counter value
1.3.6.1.4.1.20044.111.11.7.353.1.6Columnpm100gfmuxdPerfTelecomBerLinePreFecPast15StatHistoryInvMaxBerPort1read-onlycurrentPrevious 15-min MaxBER counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.7.353.1.7Columnpm100gfmuxdPerfTelecomBerLinePreFecPast15StatHistoryMaxBerValuePort1read-onlycurrentPrevious 15-min MaxBER counter :This OID gives the previous 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.111.11.7.354Tablepm100gfmuxdPerfTelecomBerLinePreFecCurrent24StatTablenot-accessiblecurrentList of pm100gfmuxdPerfTelecomBerLinePreFecCurrent24Stat Article
1.3.6.1.4.1.20044.111.11.7.354.1Rowpm100gfmuxdPerfTelecomBerLinePreFecCurrent24StatEntrynot-accessiblecurrentRow definition for the pm100gfmuxdPerfTelecomBerLinePreFecCurrent24Stat table
1.3.6.1.4.1.20044.111.11.7.354.1.1Columnpm100gfmuxdPerfTelecomBerLinePreFecCurrent24StatIndexread-onlycurrentIndex definition for the pm100gfmuxdPerfTelecomBerLinePreFecCurrent24Stat table
1.3.6.1.4.1.20044.111.11.7.354.1.2Columnpm100gfmuxdPerfTelecomBerLinePreFecCurrent24StatInvBerPortnread-onlycurrentCurrent 24-hours BER counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.111.11.7.354.1.3Columnpm100gfmuxdPerfTelecomBerLinePreFecCurrent24StatBerValuePortnread-onlycurrentCurrent 24-hours BER counter :This OID gives the current 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.111.11.7.354.1.4Columnpm100gfmuxdPerfTelecomBerLinePreFecCurrent24StatInvMinBerPortnread-onlycurrentCurrent 24-hoursMinBER counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.7.354.1.5Columnpm100gfmuxdPerfTelecomBerLinePreFecCurrent24StatMinBerValuePortnread-onlycurrentCurrent 24-hours MinBER counter :This OID gives the current 24-hours Errored Second counter value
1.3.6.1.4.1.20044.111.11.7.354.1.6Columnpm100gfmuxdPerfTelecomBerLinePreFecCurrent24StatInvMaxBerPortnread-onlycurrentCurrent 24-hours MaxBER counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.7.354.1.7Columnpm100gfmuxdPerfTelecomBerLinePreFecCurrent24StatMaxBerValuePortnread-onlycurrentCurrent 24-hours MaxBER counter :This OID gives the current 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.111.11.7.355Tablepm100gfmuxdPerfTelecomBerLinePreFecPast24StatHistoryPort1Tablenot-accessiblecurrentList of pm100gfmuxdPerfTelecomBerLinePreFecPast24StatHistory Article
1.3.6.1.4.1.20044.111.11.7.355.1Rowpm100gfmuxdPerfTelecomBerLinePreFecPast24StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pm100gfmuxdPerfTelecomBerLinePreFecPast24StatHistory table
1.3.6.1.4.1.20044.111.11.7.355.1.1Columnpm100gfmuxdPerfTelecomBerLinePreFecPast24StatHistoryPort1Indexread-onlycurrentIndex definition for the pm100gfmuxdPerfTelecomBerLinePreFecPast24StatHistory table
1.3.6.1.4.1.20044.111.11.7.355.1.2Columnpm100gfmuxdPerfTelecomBerLinePreFecPast24StatHistoryInvBerPort1read-onlycurrentPrevious 24-hours BER counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.111.11.7.355.1.3Columnpm100gfmuxdPerfTelecomBerLinePreFecPast24StatHistoryBerValuePort1read-onlycurrentPrevious 24-hours BER counter :This OID gives the previous 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.111.11.7.355.1.4Columnpm100gfmuxdPerfTelecomBerLinePreFecPast24StatHistoryInvMinBerPort1read-onlycurrentPrevious 24-hours MinBER counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.7.355.1.5Columnpm100gfmuxdPerfTelecomBerLinePreFecPast24StatHistoryMinBerValuePort1read-onlycurrentPrevious 24-hours MinBER counter :This OID gives the previous 24-hours Errored Second counter value
1.3.6.1.4.1.20044.111.11.7.355.1.6Columnpm100gfmuxdPerfTelecomBerLinePreFecPast24StatHistoryInvMaxBerPort1read-onlycurrentPrevious 24-hours MaxBER counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.111.11.7.355.1.7Columnpm100gfmuxdPerfTelecomBerLinePreFecPast24StatHistoryMaxBerValuePort1read-onlycurrentPrevious 24-hours MaxBER counter :This OID gives the previous 24-hours severely Errored Second counter value
Type Definitions
NameSyntaxStatusDescription
Pm100gfmuxdModuleModeINTEGER { modulemode2x40g(1), modulemode1x40g4x10g(2), modulemode10x10g(3) }currentDifferent values on the module mode