EKINOPS-Pm100gfmuxd-MIB
730 objects
Creation
Imported Objects
| EKINOPS-MIB | EkiApiState EkiMeasureType EkiMode ekinops EkiOnOff EkiProtocol EkiState EkiSynchroMode |
| SNMPv2-SMI | Counter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20044.111 | IdentitymodulePm100gfmuxd | Creation | ||
| 1.3.6.1.4.1.20044.111.2 | Nodepm100gfmuxdalarms | |||
| 1.3.6.1.4.1.20044.111.2.1 | Nodepm100gfmuxdAlmOther | |||
| 1.3.6.1.4.1.20044.111.2.1.1 | Nodepm100gfmuxdAlmOtherNurg | |||
| 1.3.6.1.4.1.20044.111.2.1.1.2 | Nodepm100gfmuxdAlmsynthAlm2 | |||
| 1.3.6.1.4.1.20044.111.2.1.1.2.1 | Scalarpm100gfmuxdAlmConfTableSave | read-only | current | PM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> infor… |
| 1.3.6.1.4.1.20044.111.2.1.1.2.2 | Scalarpm100gfmuxdAlmInvUpload | read-only | current | Inventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> informationalStatus(1000) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.111.2.1.1.2.3 | Scalarpm100gfmuxdAlmConfTableLoad | read-only | current | PM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> informationalStat… |
| 1.3.6.1.4.1.20044.111.2.1.1.2.4 | Scalarpm100gfmuxdAlmCorrelatOff | read-only | current | Not Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> informationalStatus(1000) <Alarmtype… |
| 1.3.6.1.4.1.20044.111.2.1.1.2.5 | Scalarpm100gfmuxdAlmMaintenanceOn | read-only | current | Maintenance Mode :This OID indicates that the RM is in maintenance mode. <Help> This alarm indicates that the maintenance mode is enabled on the PM <Condtype> … |
| 1.3.6.1.4.1.20044.111.2.1.2 | Nodepm100gfmuxdAlmOtherUrg | |||
| 1.3.6.1.4.1.20044.111.2.1.3 | Nodepm100gfmuxdAlmOtherCrit | |||
| 1.3.6.1.4.1.20044.111.2.1.3.0 | Nodepm100gfmuxdAlmsynthAlm0 | |||
| 1.3.6.1.4.1.20044.111.2.1.3.0.2 | Scalarpm100gfmuxdAlmFailFan | read-only | current | Fan Fail :This OID is at 1 when any fail occurs on the fan tray <Help> This alarm indicates that the Fan tray module is in a failure condition <Condtype> FAIL_… |
| 1.3.6.1.4.1.20044.111.2.1.3.0.9 | Scalarpm100gfmuxdAlmModGlobFail | read-only | current | Module Failure :This OID is set on detection of a failure originating from the RM <Help> This alarm is set on detection of a failure originating from the equip… |
| 1.3.6.1.4.1.20044.111.2.1.3.0.15 | Scalarpm100gfmuxdAlmDefFuseA | read-only | current | Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.111.2.1.3.0.16 | Scalarpm100gfmuxdAlmDefFuseB | read-only | current | Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.111.2.2 | Nodepm100gfmuxdAlmClient | |||
| 1.3.6.1.4.1.20044.111.2.2.1 | Nodepm100gfmuxdAlmClientNurg | |||
| 1.3.6.1.4.1.20044.111.2.2.1.272 | Tablepm100gfmuxdAlmclientSfpWarnDdmTable | not-accessible | current | List of pm100gfmuxdAlmclientSfpWarnDdm Article |
| 1.3.6.1.4.1.20044.111.2.2.1.272.1 | Rowpm100gfmuxdAlmclientSfpWarnDdmEntry | not-accessible | current | Row definition for the pm100gfmuxdAlmclientSfpWarnDdm table |
| 1.3.6.1.4.1.20044.111.2.2.1.272.1.1 | Columnpm100gfmuxdAlmclientSfpWarnDdmIndex | read-only | current | Index definition for the pm100gfmuxdAlmclientSfpWarnDdm table |
| 1.3.6.1.4.1.20044.111.2.2.1.272.1.2 | Columnpm100gfmuxdAlmTxPwLowWngPortn | read-only | current | Client Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning … |
| 1.3.6.1.4.1.20044.111.2.2.1.272.1.3 | Columnpm100gfmuxdAlmTxPwrHighWngPortn | read-only | current | Client Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warnin… |
| 1.3.6.1.4.1.20044.111.2.2.1.272.1.4 | Columnpm100gfmuxdAlmTxBiasLowWngPortn | read-only | current | Client Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warnin… |
| 1.3.6.1.4.1.20044.111.2.2.1.272.1.5 | Columnpm100gfmuxdAlmTxBiasHighWngPortn | read-only | current | Client Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warn… |
| 1.3.6.1.4.1.20044.111.2.2.1.272.1.6 | Columnpm100gfmuxdAlmVccLowWngPortn | read-only | current | Client Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Warn… |
| 1.3.6.1.4.1.20044.111.2.2.1.272.1.7 | Columnpm100gfmuxdAlmVccHighWngPortn | read-only | current | Client Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Wa… |
| 1.3.6.1.4.1.20044.111.2.2.1.272.1.8 | Columnpm100gfmuxdAlmTempLowWngPortn | read-only | current | Client Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indic… |
| 1.3.6.1.4.1.20044.111.2.2.1.272.1.9 | Columnpm100gfmuxdAlmTempHighWngPortn | read-only | current | Client Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning ind… |
| 1.3.6.1.4.1.20044.111.2.2.1.272.1.16 | Columnpm100gfmuxdAlmRxPwrLowWngPortn | read-only | current | Client Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning i… |
| 1.3.6.1.4.1.20044.111.2.2.1.272.1.17 | Columnpm100gfmuxdAlmRxPwrHighWngPortn | read-only | current | Client Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning… |
| 1.3.6.1.4.1.20044.111.2.2.2 | Nodepm100gfmuxdAlmClientUrg | |||
| 1.3.6.1.4.1.20044.111.2.2.2.152 | Tablepm100gfmuxdAlmclientHostLaneFaultTable | not-accessible | current | List of pm100gfmuxdAlmclientHostLaneFault Article |
| 1.3.6.1.4.1.20044.111.2.2.2.152.1 | Rowpm100gfmuxdAlmclientHostLaneFaultEntry | not-accessible | current | Row definition for the pm100gfmuxdAlmclientHostLaneFault table |
| 1.3.6.1.4.1.20044.111.2.2.2.152.1.1 | Columnpm100gfmuxdAlmclientHostLaneFaultIndex | read-only | current | Index definition for the pm100gfmuxdAlmclientHostLaneFault table |
| 1.3.6.1.4.1.20044.111.2.2.2.152.1.2 | Columnpm100gfmuxdAlmClientLossOfSyncPortn | read-only | current | Client Frame Alignment Loss :This OID indicates the module is not aligned with the incoming Client signal <Help> Alarm indicating the module is not aligned wit… |
| 1.3.6.1.4.1.20044.111.2.2.2.152.1.3 | Columnpm100gfmuxdAlmClientInputLossOfSigPortn | read-only | current | Client Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Client Trscv <Help> Alarm indicating a Loss of Signal is detected on the Cl… |
| 1.3.6.1.4.1.20044.111.2.2.2.152.1.4 | Columnpm100gfmuxdAlmClientLanesMarkerUnlockPortn | read-only | current | Client Lanes Marker Unlock :This OID indicates the Client lanes marker alignment is not lock <Help> Alarm indicating the Client lanes marker alignment is not l… |
| 1.3.6.1.4.1.20044.111.2.2.2.152.1.5 | Columnpm100gfmuxdAlmClientLanes6466UnlockPortn | read-only | current | Client Lanes 64/66b Unlock :This OID indicates the Client 64/66b decoder is not lock <Help> Alarm indicating the Client 64/66b decoder is not lock <Condtype> C… |
| 1.3.6.1.4.1.20044.111.2.2.2.152.1.6 | Columnpm100gfmuxdAlmClientLanesNotAlignedPortn | read-only | current | Client Lanes Not Aligned :This OID indicates the Client lanes are not aligned <Help> Alarm indicating the Client lanes are not aligned <Condtype> CLIENT_LANES_… |
| 1.3.6.1.4.1.20044.111.2.2.2.152.1.7 | Columnpm100gfmuxdAlmClientCsfDetectedPortn | read-only | current | Client Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client… |
| 1.3.6.1.4.1.20044.111.2.2.2.152.1.10 | Columnpm100gfmuxdAlmClientTxHostLolPortn | read-only | current | Client Host Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Client Trscv Host Lane <Help> Alarm indicating a Tx Loss of Lock on the Client Tr… |
| 1.3.6.1.4.1.20044.111.2.2.2.152.1.11 | Columnpm100gfmuxdAlmClientLaneTxFifoErrorPortn | read-only | current | Client Host Lane Tx FIFO Error :This OID indicates a Tx FIFO Error on the Client Trscv Host Lane <Help> Alarm indicating a Tx FIFO Error on the Client Trscv Ho… |
| 1.3.6.1.4.1.20044.111.2.2.2.240 | Tablepm100gfmuxdAlmclientSfpAlmDdmTable | not-accessible | current | List of pm100gfmuxdAlmclientSfpAlmDdm Article |
| 1.3.6.1.4.1.20044.111.2.2.2.240.1 | Rowpm100gfmuxdAlmclientSfpAlmDdmEntry | not-accessible | current | Row definition for the pm100gfmuxdAlmclientSfpAlmDdm table |
| 1.3.6.1.4.1.20044.111.2.2.2.240.1.1 | Columnpm100gfmuxdAlmclientSfpAlmDdmIndex | read-only | current | Index definition for the pm100gfmuxdAlmclientSfpAlmDdm table |
| 1.3.6.1.4.1.20044.111.2.2.2.240.1.2 | Columnpm100gfmuxdAlmTxPwrLowAlaPortn | read-only | current | Client Trscv Tx Power Low :This OID indicates that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in… |
| 1.3.6.1.4.1.20044.111.2.2.2.240.1.3 | Columnpm100gfmuxdAlmTxPwrHighAlaPortn | read-only | current | Client Trscv Tx Power High :This OID indicates that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm … |
| 1.3.6.1.4.1.20044.111.2.2.2.240.1.4 | Columnpm100gfmuxdAlmTxBiasLowAlaPortn | read-only | current | Client Trscv Bias Low :This OID indicates that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm … |
| 1.3.6.1.4.1.20044.111.2.2.2.240.1.5 | Columnpm100gfmuxdAlmTxBiasHighAlaPortn | read-only | current | Client Trscv Bias High :This OID indicates that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM <Help> Alar… |
| 1.3.6.1.4.1.20044.111.2.2.2.240.1.6 | Columnpm100gfmuxdAlmVccLowAlaPortn | read-only | current | Client Trscv Power Supply Low :This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM <Help> Alar… |
| 1.3.6.1.4.1.20044.111.2.2.2.240.1.7 | Columnpm100gfmuxdAlmVccHighAlaPortn | read-only | current | Client Trscv Power Supply High :This OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM <Help> Al… |
| 1.3.6.1.4.1.20044.111.2.2.2.240.1.8 | Columnpm100gfmuxdAlmTempLowAlaPortn | read-only | current | Client Trscv Temp Low :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicat… |
| 1.3.6.1.4.1.20044.111.2.2.2.240.1.9 | Columnpm100gfmuxdAlmTempHighAlaPortn | read-only | current | Client Trscv Temp High :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indic… |
| 1.3.6.1.4.1.20044.111.2.2.2.240.1.16 | Columnpm100gfmuxdAlmRxPwrLowAlaPortn | read-only | current | Client Trscv Rx Power Low :This OID indicates that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm ind… |
| 1.3.6.1.4.1.20044.111.2.2.2.240.1.17 | Columnpm100gfmuxdAlmRxPwrHighAlaPortn | read-only | current | Client Trscv Rx Power High :This OID indicates that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm i… |
| 1.3.6.1.4.1.20044.111.2.2.3 | Nodepm100gfmuxdAlmClientCrit | |||
| 1.3.6.1.4.1.20044.111.2.2.3.8 | Tablepm100gfmuxdAlmsynthAlmPortTable | not-accessible | current | List of pm100gfmuxdAlmsynthAlmPort Article |
| 1.3.6.1.4.1.20044.111.2.2.3.8.1 | Rowpm100gfmuxdAlmsynthAlmPortEntry | not-accessible | current | Row definition for the pm100gfmuxdAlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.111.2.2.3.8.1.1 | Columnpm100gfmuxdAlmsynthAlmPortIndex | read-only | current | Index definition for the pm100gfmuxdAlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.111.2.2.3.8.1.2 | Columnpm100gfmuxdAlmSfpAbsentPortn | read-only | current | Client Optical Module Absent :This OID indicates that the Transceiver is not present in the client port. <Help> This alarm indicates if the client transceiver … |
| 1.3.6.1.4.1.20044.111.2.2.3.8.1.3 | Columnpm100gfmuxdAlmDdmAbsentPortn | read-only | current | DDM Supported On Client Trscv :This OID indicates that the Client transceiver supports the Digital Diagnostic Monitoring function <Help> This status indicates … |
| 1.3.6.1.4.1.20044.111.2.2.3.8.1.5 | Columnpm100gfmuxdAlmHwFailAccPortn | read-only | current | Client HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Help> This alarm indicates a failure on client port, most pro… |
| 1.3.6.1.4.1.20044.111.2.2.3.8.1.6 | Columnpm100gfmuxdAlmDwLsdPortn | read-only | current | Client Trscv Laser Shutdown :This OID indicates the Client transceiver laser is shutdown <Help> This status indicates if the client transceiver laser is shutdo… |
| 1.3.6.1.4.1.20044.111.2.2.3.8.1.7 | Columnpm100gfmuxdAlmClientLocalOosPortn | read-only | current | Local Client Port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local c… |
| 1.3.6.1.4.1.20044.111.2.2.3.8.1.8 | Columnpm100gfmuxdAlmClientRemoteOosPortn | read-only | current | Remote Client Port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the remot… |
| 1.3.6.1.4.1.20044.111.2.2.3.8.1.9 | Columnpm100gfmuxdAlmDwCaisPortn | read-only | current | Client AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indicates if a Client Alarm Indication Signal is… |
| 1.3.6.1.4.1.20044.111.2.2.3.8.1.10 | Columnpm100gfmuxdAlmSfpDdmWarningPortn | read-only | current | Warning On Client Trscv DDM :This OID indicates a warning is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Warning has be… |
| 1.3.6.1.4.1.20044.111.2.2.3.8.1.11 | Columnpm100gfmuxdAlmSfpDdmAlmPortn | read-only | current | Alarm On Client Trscv DDM :This OID indicates an alarm is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Alarm has been de… |
| 1.3.6.1.4.1.20044.111.2.2.3.8.1.13 | Columnpm100gfmuxdAlmFailAccPortn | read-only | current | Client Access Fail :This OID indicates a failure on the Client port <Help> This alarm indicates a failure on the Client port <Condtype> FAIL_ACC_1 <Probcause> … |
| 1.3.6.1.4.1.20044.111.2.2.3.8.1.14 | Columnpm100gfmuxdAlmClientLoopbackOnPortn | read-only | current | Client Loopback Enabled :This OID indicates a loopback is enabled on the port <Help> This alarm indicates a loopback is enabled on the port <Condtype> CLIENT_L… |
| 1.3.6.1.4.1.20044.111.2.2.3.8.1.17 | Columnpm100gfmuxdAlmUpCsfPortn | read-only | current | Client Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu… |
| 1.3.6.1.4.1.20044.111.2.3 | Nodepm100gfmuxdAlmLine | |||
| 1.3.6.1.4.1.20044.111.2.3.1 | Nodepm100gfmuxdAlmLineNurg | |||
| 1.3.6.1.4.1.20044.111.2.3.1.104 | Tablepm100gfmuxdAlmlineQsfpWarnDdmTable | not-accessible | current | List of pm100gfmuxdAlmlineQsfpWarnDdm Article |
| 1.3.6.1.4.1.20044.111.2.3.1.104.1 | Rowpm100gfmuxdAlmlineQsfpWarnDdmEntry | not-accessible | current | Row definition for the pm100gfmuxdAlmlineQsfpWarnDdm table |
| 1.3.6.1.4.1.20044.111.2.3.1.104.1.1 | Columnpm100gfmuxdAlmlineQsfpWarnDdmIndex | read-only | current | Index definition for the pm100gfmuxdAlmlineQsfpWarnDdm table |
| 1.3.6.1.4.1.20044.111.2.3.1.104.1.2 | Columnpm100gfmuxdAlmLineTxPwLowWngPortn | read-only | current | Line Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning in… |
| 1.3.6.1.4.1.20044.111.2.3.1.104.1.3 | Columnpm100gfmuxdAlmLineTxPwrHighWngPortn | read-only | current | Line Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warning … |
| 1.3.6.1.4.1.20044.111.2.3.1.104.1.4 | Columnpm100gfmuxdAlmLineTxBiasLowWngPortn | read-only | current | Line Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warning … |
| 1.3.6.1.4.1.20044.111.2.3.1.104.1.5 | Columnpm100gfmuxdAlmLineTxBiasHighWngPortn | read-only | current | Line Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warnin… |
| 1.3.6.1.4.1.20044.111.2.3.1.104.1.6 | Columnpm100gfmuxdAlmLineVccLowWngPortn | read-only | current | Line Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Warnin… |
| 1.3.6.1.4.1.20044.111.2.3.1.104.1.7 | Columnpm100gfmuxdAlmLineVccHighWngPortn | read-only | current | Line Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Warn… |
| 1.3.6.1.4.1.20044.111.2.3.1.104.1.8 | Columnpm100gfmuxdAlmLineTempLowWngPortn | read-only | current | Line Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indicat… |
| 1.3.6.1.4.1.20044.111.2.3.1.104.1.9 | Columnpm100gfmuxdAlmLineTempHighWngPortn | read-only | current | Line Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning indic… |
| 1.3.6.1.4.1.20044.111.2.3.1.104.1.16 | Columnpm100gfmuxdAlmLineRxPwrLowWngPortn | read-only | current | Line Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning ind… |
| 1.3.6.1.4.1.20044.111.2.3.1.104.1.17 | Columnpm100gfmuxdAlmLineRxPwrHighWngPortn | read-only | current | Line Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning i… |
| 1.3.6.1.4.1.20044.111.2.3.1.184 | Tablepm100gfmuxdAlmlineNetworkLaneAlarmWarning1Table | not-accessible | current | List of pm100gfmuxdAlmlineNetworkLaneAlarmWarning1 Article |
| 1.3.6.1.4.1.20044.111.2.3.1.184.1 | Rowpm100gfmuxdAlmlineNetworkLaneAlarmWarning1Entry | not-accessible | current | Row definition for the pm100gfmuxdAlmlineNetworkLaneAlarmWarning1 table |
| 1.3.6.1.4.1.20044.111.2.3.1.184.1.1 | Columnpm100gfmuxdAlmlineNetworkLaneAlarmWarning1Index | read-only | current | Index definition for the pm100gfmuxdAlmlineNetworkLaneAlarmWarning1 table |
| 1.3.6.1.4.1.20044.111.2.3.1.184.1.2 | Columnpm100gfmuxdAlmLineRxPowerLowAlarmPortn | read-only | current | Line Trscv Rx Power Low Alarm :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicat… |
| 1.3.6.1.4.1.20044.111.2.3.1.184.1.3 | Columnpm100gfmuxdAlmLineRxPowerLowWarningPortn | read-only | current | Line Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning ind… |
| 1.3.6.1.4.1.20044.111.2.3.1.184.1.4 | Columnpm100gfmuxdAlmLineRxPowerHighWarningPortn | read-only | current | Line Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning i… |
| 1.3.6.1.4.1.20044.111.2.3.1.184.1.5 | Columnpm100gfmuxdAlmLineRxPowerHighAlarmPortn | read-only | current | Line Trscv Rx Power High Alarm :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indic… |
| 1.3.6.1.4.1.20044.111.2.3.1.184.1.6 | Columnpm100gfmuxdAlmLineLaserTempLowAlarmPortn | read-only | current | Line Trscv Tx Laser Temp Low Alarm :This OID indicates that the Trscv Tx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help>… |
| 1.3.6.1.4.1.20044.111.2.3.1.184.1.7 | Columnpm100gfmuxdAlmLineLaserTempLowWarningPortn | read-only | current | Line Trscv Tx Laser Temp Low Warning :This OID indicates that the Trscv Tx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Hel… |
| 1.3.6.1.4.1.20044.111.2.3.1.184.1.8 | Columnpm100gfmuxdAlmLineLaserTempHighWarningPortn | read-only | current | Line Trscv Tx Laser Temp High Warning :This OID indicates that the Trscv Tx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <H… |
| 1.3.6.1.4.1.20044.111.2.3.1.184.1.9 | Columnpm100gfmuxdAlmLineLaserTempHighAlarmPortn | read-only | current | Line Trscv Tx Laser Temp High Alarm :This OID indicates that the Trscv Tx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Hel… |
| 1.3.6.1.4.1.20044.111.2.3.1.184.1.10 | Columnpm100gfmuxdAlmLineTxPowerLowAlarmPortn | read-only | current | Line Trscv Tx Power Low Alarm :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indica… |
| 1.3.6.1.4.1.20044.111.2.3.1.184.1.11 | Columnpm100gfmuxdAlmLineTxPowerLowWarningPortn | read-only | current | Line Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning in… |
| 1.3.6.1.4.1.20044.111.2.3.1.184.1.12 | Columnpm100gfmuxdAlmLineTxPowerHighWarningPortn | read-only | current | Line Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warning … |
| 1.3.6.1.4.1.20044.111.2.3.1.184.1.13 | Columnpm100gfmuxdAlmLineTxPowerHighAlarmPortn | read-only | current | Line Trscv Tx Power High Alarm :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indi… |
| 1.3.6.1.4.1.20044.111.2.3.1.184.1.14 | Columnpm100gfmuxdAlmLineBiasLowAlarmPortn | read-only | current | Line Trscv Tx Bias Low Alarm :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alarm i… |
| 1.3.6.1.4.1.20044.111.2.3.1.184.1.15 | Columnpm100gfmuxdAlmLineBiasLowWarningPortn | read-only | current | Line Trscv Tx Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warni… |
| 1.3.6.1.4.1.20044.111.2.3.1.184.1.16 | Columnpm100gfmuxdAlmLineBiasHighWarningPortn | read-only | current | Line Trscv Tx Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> War… |
| 1.3.6.1.4.1.20044.111.2.3.1.184.1.17 | Columnpm100gfmuxdAlmLineBiasHighAlarmPortn | read-only | current | Line Trscv Tx Bias High Alarm :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Alarm… |
| 1.3.6.1.4.1.20044.111.2.3.1.188 | Tablepm100gfmuxdAlmlineNetworkLaneAlarmWarning2Table | not-accessible | current | List of pm100gfmuxdAlmlineNetworkLaneAlarmWarning2 Article |
| 1.3.6.1.4.1.20044.111.2.3.1.188.1 | Rowpm100gfmuxdAlmlineNetworkLaneAlarmWarning2Entry | not-accessible | current | Row definition for the pm100gfmuxdAlmlineNetworkLaneAlarmWarning2 table |
| 1.3.6.1.4.1.20044.111.2.3.1.188.1.1 | Columnpm100gfmuxdAlmlineNetworkLaneAlarmWarning2Index | read-only | current | Index definition for the pm100gfmuxdAlmlineNetworkLaneAlarmWarning2 table |
| 1.3.6.1.4.1.20044.111.2.3.1.188.1.2 | Columnpm100gfmuxdAlmTxModulatorBiasLowAlarmPortn | read-only | current | Line Trscv Tx Modulator Bias Low Alarm :This OID indicates that the Trscv Tx modulator bias current is lower than the threshold value written in the Trscv EEPR… |
| 1.3.6.1.4.1.20044.111.2.3.1.188.1.3 | Columnpm100gfmuxdAlmTxModulatorBiasLowWarningPortn | read-only | current | Line Trscv Tx Modulator Bias Low Warning :This OID indicates that the Trscv Tx modulator bias current is lower than the threshold value written in the Trscv EE… |
| 1.3.6.1.4.1.20044.111.2.3.1.188.1.4 | Columnpm100gfmuxdAlmTxModulatorBiasHighWarningPortn | read-only | current | Line Trscv Tx Modulator Bias High Warning :This OID indicates that the Trscv Tx modulator bias current is higher than the threshold value written in the Trscv … |
| 1.3.6.1.4.1.20044.111.2.3.1.188.1.5 | Columnpm100gfmuxdAlmTxModulatorBiasHighAlarmPortn | read-only | current | Line Trscv Tx Modulator Bias High Alarm :This OID indicates that the Trscv Tx modulator bias current is higher than the threshold value written in the Trscv EE… |
| 1.3.6.1.4.1.20044.111.2.3.1.188.1.6 | Columnpm100gfmuxdAlmRxLaserTempLowAlarmPortn | read-only | current | Line Trscv Rx Laser Temp Low Alarm :This OID indicates that the Trscv Rx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help>… |
| 1.3.6.1.4.1.20044.111.2.3.1.188.1.7 | Columnpm100gfmuxdAlmRxLaserTempLowWarningPortn | read-only | current | Line Trscv Rx Laser Temp Low Warning :This OID indicates that the Trscv Rx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Hel… |
| 1.3.6.1.4.1.20044.111.2.3.1.188.1.8 | Columnpm100gfmuxdAlmRxLaserTempHighWarningPortn | read-only | current | Line Trscv Rx Laser Temp High Warning :This OID indicates that the Trscv Rx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <H… |
| 1.3.6.1.4.1.20044.111.2.3.1.188.1.9 | Columnpm100gfmuxdAlmRxLaserTempHighAlarmPortn | read-only | current | Line Trscv Rx Laser Temp High Alarm :This OID indicates that the Trscv Rx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Hel… |
| 1.3.6.1.4.1.20044.111.2.3.1.188.1.10 | Columnpm100gfmuxdAlmRxLaserOutputLowAlarmPortn | read-only | current | Line Trscv Rx Output Power Low Alarm :This OID indicates that the Trscv Rx output power is lower than the threshold value written in the Trscv EEPROM <Help> Al… |
| 1.3.6.1.4.1.20044.111.2.3.1.188.1.11 | Columnpm100gfmuxdAlmRxLaserOutputLowWarningPortn | read-only | current | Line Trscv Rx Output Power Low Warning :This OID indicates that the Trscv Rx output power is lower than the threshold value written in the Trscv EEPROM <Help> … |
| 1.3.6.1.4.1.20044.111.2.3.1.188.1.12 | Columnpm100gfmuxdAlmRxLaserOutputHighWarningPortn | read-only | current | Line Trscv Rx Output Power High Warning :This OID indicates that the Trscv Rx output power is higher than the threshold value written in the Trscv EEPROM <Help… |
| 1.3.6.1.4.1.20044.111.2.3.1.188.1.13 | Columnpm100gfmuxdAlmRxLaserOutputHighAlarmPortn | read-only | current | Line Trscv Rx Output Power High Alarm :This OID indicates that the Trscv Rx output power is higher than the threshold value written in the Trscv EEPROM <Help> … |
| 1.3.6.1.4.1.20044.111.2.3.1.188.1.14 | Columnpm100gfmuxdAlmRxLaserBiasLowAlarmPortn | read-only | current | Line Trscv Rx Bias Low Alarm :This OID indicates that the Trscv Rx laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alar… |
| 1.3.6.1.4.1.20044.111.2.3.1.188.1.15 | Columnpm100gfmuxdAlmRxLaserBiasLowWarningPortn | read-only | current | Line Trscv Rx Bias Low Warning :This OID indicates that the Trscv Rx laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Wa… |
| 1.3.6.1.4.1.20044.111.2.3.1.188.1.16 | Columnpm100gfmuxdAlmRxLaserBiasHighWarningPortn | read-only | current | Line Trscv Rx Bias High Warning :This OID indicates that the Trscv Rx laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> … |
| 1.3.6.1.4.1.20044.111.2.3.1.188.1.17 | Columnpm100gfmuxdAlmRxLaserBiasHighAlarmPortn | read-only | current | Line Trscv Rx Bias High Alarm :This OID indicates that the Trscv Rx laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Al… |
| 1.3.6.1.4.1.20044.111.2.3.2 | Nodepm100gfmuxdAlmLineUrg | |||
| 1.3.6.1.4.1.20044.111.2.3.2.72 | Tablepm100gfmuxdAlmlineQsfpAlmDdmTable | not-accessible | current | List of pm100gfmuxdAlmlineQsfpAlmDdm Article |
| 1.3.6.1.4.1.20044.111.2.3.2.72.1 | Rowpm100gfmuxdAlmlineQsfpAlmDdmEntry | not-accessible | current | Row definition for the pm100gfmuxdAlmlineQsfpAlmDdm table |
| 1.3.6.1.4.1.20044.111.2.3.2.72.1.1 | Columnpm100gfmuxdAlmlineQsfpAlmDdmIndex | read-only | current | Index definition for the pm100gfmuxdAlmlineQsfpAlmDdm table |
| 1.3.6.1.4.1.20044.111.2.3.2.72.1.2 | Columnpm100gfmuxdAlmLineTxPwLowAlmPortn | read-only | current | Line Trscv Tx Power Low Alarm :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indica… |
| 1.3.6.1.4.1.20044.111.2.3.2.72.1.3 | Columnpm100gfmuxdAlmLineTxPwrHighAlmPortn | read-only | current | Line Trscv Tx Power High Alarm :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indi… |
| 1.3.6.1.4.1.20044.111.2.3.2.72.1.4 | Columnpm100gfmuxdAlmLineTxBiasLowAlmPortn | read-only | current | Line Trscv Bias Low Alarm :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indi… |
| 1.3.6.1.4.1.20044.111.2.3.2.72.1.5 | Columnpm100gfmuxdAlmLineTxBiasHighAlmPortn | read-only | current | Line Trscv Bias High Alarm :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Alarm in… |
| 1.3.6.1.4.1.20044.111.2.3.2.72.1.6 | Columnpm100gfmuxdAlmLineVccLowAlmPortn | read-only | current | Line Trscv Power Supply Low Alarm :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in… |
| 1.3.6.1.4.1.20044.111.2.3.2.72.1.7 | Columnpm100gfmuxdAlmLineVccHighAlmPortn | read-only | current | Line Trscv Power Supply High Alarm :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Alarm … |
| 1.3.6.1.4.1.20044.111.2.3.2.72.1.8 | Columnpm100gfmuxdAlmLineTempLowAlmPortn | read-only | current | Line Trscv Temp Low Alarm :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicating … |
| 1.3.6.1.4.1.20044.111.2.3.2.72.1.9 | Columnpm100gfmuxdAlmLineTempHighAlmPortn | read-only | current | Line Trscv Temp High Alarm :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indicatin… |
| 1.3.6.1.4.1.20044.111.2.3.2.72.1.16 | Columnpm100gfmuxdAlmLineRxPwrLowAlmPortn | read-only | current | Line Trscv Rx Power Low Alarm :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicat… |
| 1.3.6.1.4.1.20044.111.2.3.2.72.1.17 | Columnpm100gfmuxdAlmLineRxPwrHighAlmPortn | read-only | current | Line Trscv Rx Power High Alarm :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indic… |
| 1.3.6.1.4.1.20044.111.2.3.2.196 | Tablepm100gfmuxdAlmlineHostLaneFaultTable | not-accessible | current | List of pm100gfmuxdAlmlineHostLaneFault Article |
| 1.3.6.1.4.1.20044.111.2.3.2.196.1 | Rowpm100gfmuxdAlmlineHostLaneFaultEntry | not-accessible | current | Row definition for the pm100gfmuxdAlmlineHostLaneFault table |
| 1.3.6.1.4.1.20044.111.2.3.2.196.1.1 | Columnpm100gfmuxdAlmlineHostLaneFaultIndex | read-only | current | Index definition for the pm100gfmuxdAlmlineHostLaneFault table |
| 1.3.6.1.4.1.20044.111.2.3.2.196.1.2 | Columnpm100gfmuxdAlmLineInputLossOfSignalPortn | read-only | current | Line Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Line Trscv <Help> Alarm indicating a Loss of Signal is detected on the Line T… |
| 1.3.6.1.4.1.20044.111.2.3.2.196.1.3 | Columnpm100gfmuxdAlmLineLossOfFramePortn | read-only | current | Line Loss Of Frame :This OID indicates the module is not aligned with the incoming Line signal <Help> Alarm indicating the module is not aligned with the incom… |
| 1.3.6.1.4.1.20044.111.2.3.2.196.1.4 | Columnpm100gfmuxdAlmLineSmBdiInsertedPortn | read-only | current | Line SM BDI Inserted :This OID indicates a SM Backward Defect Indication is inserted on the outgoing Line signal <Help> Status indicating a SM Backward Defect … |
| 1.3.6.1.4.1.20044.111.2.3.2.196.1.5 | Columnpm100gfmuxdAlmLineSmBdiDetectedPortn | read-only | current | Line SM BDI Detected :This OID indicates a SM Backward Defect Indication is detected on the incoming Line signal <Help> Alarm indicating a SM Backward Defect I… |
| 1.3.6.1.4.1.20044.111.2.3.2.196.1.6 | Columnpm100gfmuxdAlmLineSmIaeInsertedPortn | read-only | current | Line SM IAE Inserted :This OID indicates a SM Incoming Alignment Error is inserted on the outgoing Line signal <Help> Status indicating a SM Incoming Alignment… |
| 1.3.6.1.4.1.20044.111.2.3.2.196.1.7 | Columnpm100gfmuxdAlmLineSmIaeDetectedPortn | read-only | current | Line SM IAE Detected :This OID indicates a SM Incoming Alignment Error is detected on the incoming Line signal <Help> Alarm indicating a SM Incoming Alignment … |
| 1.3.6.1.4.1.20044.111.2.3.2.196.1.10 | Columnpm100gfmuxdAlmLineEncryptionFailurePortn | read-only | current | Encryption Failure :This OID indicates the encryption mechanism failed, impacting the traffic (the line traffic is down). <Help> This alarm indicates the encry… |
| 1.3.6.1.4.1.20044.111.2.3.3 | Nodepm100gfmuxdAlmLineCrit | |||
| 1.3.6.1.4.1.20044.111.2.3.3.40 | Tablepm100gfmuxdAlmsynthAlmLineTable | not-accessible | current | List of pm100gfmuxdAlmsynthAlmLine Article |
| 1.3.6.1.4.1.20044.111.2.3.3.40.1 | Rowpm100gfmuxdAlmsynthAlmLineEntry | not-accessible | current | Row definition for the pm100gfmuxdAlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.111.2.3.3.40.1.1 | Columnpm100gfmuxdAlmsynthAlmLineIndex | read-only | current | Index definition for the pm100gfmuxdAlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.111.2.3.3.40.1.2 | Columnpm100gfmuxdAlmXfpAbsentPortn | read-only | current | Line Optical Module Absent :This OID indicates that the line optical interface is not present. <Help> This alarm indicates if the line transceiver is not plugg… |
| 1.3.6.1.4.1.20044.111.2.3.3.40.1.3 | Columnpm100gfmuxdAlmXfpInitNotComplPortn | read-only | current | Line Optical Module Ready :This OID indicates that the optical interface is not operational. <Help> This status indicates if the line transceiver has been corr… |
| 1.3.6.1.4.1.20044.111.2.3.3.40.1.5 | Columnpm100gfmuxdAlmLineHwFailPortn | read-only | current | Line Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Help> This alarm indicates a failure on line port, most pr… |
| 1.3.6.1.4.1.20044.111.2.3.3.40.1.6 | Columnpm100gfmuxdAlmXfpTxOffPortn | read-only | current | Line Trscv Laser Shutdown :This OID indicates the Line transceiver laser is shutdown <Help> This status indicates if the Line transceiver laser is shutdown <Co… |
| 1.3.6.1.4.1.20044.111.2.3.3.40.1.7 | Columnpm100gfmuxdAlmLineLocalOosPortn | read-only | current | Line Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service… |
| 1.3.6.1.4.1.20044.111.2.3.3.40.1.9 | Columnpm100gfmuxdAlmUpRdiInsPortn | read-only | current | MS-RDI/L-RDI Inserted On Line :This OID indicates an upstream MS-RDI/L-RDI has been inserted in the outgoing 10 Gb/s SDH/SONET signal. <Help> This status indic… |
| 1.3.6.1.4.1.20044.111.2.3.3.40.1.10 | Columnpm100gfmuxdAlmLineDdmWarningPortn | read-only | current | Warning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Warning has… |
| 1.3.6.1.4.1.20044.111.2.3.3.40.1.11 | Columnpm100gfmuxdAlmLineDdmAlmPortn | read-only | current | Alarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Alarm has been… |
| 1.3.6.1.4.1.20044.111.2.3.3.40.1.13 | Columnpm100gfmuxdAlmLineFailPortn | read-only | current | Line Port Failure :This OID indicates a failure on the line port <Help> This alarm indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipm… |
| 1.3.6.1.4.1.20044.111.2.3.3.40.1.14 | Columnpm100gfmuxdAlmLineLoopbackOnPortn | read-only | current | Line Loopback Enabled :This OID indicates a loopback is enabled on the port <Help> This alarm indicates a loopback is enabled on the port <Condtype> LINE_LOOPB… |
| 1.3.6.1.4.1.20044.111.2.3.3.40.1.17 | Columnpm100gfmuxdAlmLineActivePortn | read-only | current | Line Active :This OID indicates whether the line is active or standby. <Help> This status indicates whether the line is active or standby. <Condtype> LINE_ACTI… |
| 1.3.6.1.4.1.20044.111.3 | Nodepm100gfmuxdmeasures | |||
| 1.3.6.1.4.1.20044.111.3.1 | Nodepm100gfmuxdMesrOther | |||
| 1.3.6.1.4.1.20044.111.3.1.400 | Scalarpm100gfmuxdMesrlineTrscv1Temp | read-only | current | Line Trscv Q4 Temperature :This OID gives the temperature value of the Transceiver Q4, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV_S16/… |
| 1.3.6.1.4.1.20044.111.3.1.401 | Scalarpm100gfmuxdMesrlineTrscv2Temp | read-only | current | Line Trscv Q3 Temperature :This OID gives the temperature value of the Transceiver Q3, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV_S16/… |
| 1.3.6.1.4.1.20044.111.3.1.492 | Scalarpm100gfmuxdMesrlineTrscv1TempMin | read-only | current | Min Line Trscv 3 Temperature :This OID gives the minimum temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperat… |
| 1.3.6.1.4.1.20044.111.3.1.493 | Scalarpm100gfmuxdMesrlineTrscv2TempMin | read-only | current | Min Line Trscv 4 Temperature :This OID gives the minimum temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperat… |
| 1.3.6.1.4.1.20044.111.3.1.496 | Scalarpm100gfmuxdMesrlineTrscv1TempMax | read-only | current | Max Line Trscv 3 Temperature :This OID gives the maximum temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperat… |
| 1.3.6.1.4.1.20044.111.3.1.497 | Scalarpm100gfmuxdMesrlineTrscv2TempMax | read-only | current | Max Line Trscv 4 Temperature :This OID gives the maximum temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperat… |
| 1.3.6.1.4.1.20044.111.3.1.500 | Scalarpm100gfmuxdMesrmoduleTempMin | read-only | current | Min Module Temperature :This OID gives the minimum temperature value of the Module (Temperature = AV_S16/256) (Unit = C) <Help> This Measure gives the minimum … |
| 1.3.6.1.4.1.20044.111.3.1.501 | Scalarpm100gfmuxdMesrmoduleTempMax | read-only | current | Max Module Temperature :This OID gives the maximum temperature value of the Module (Temperature = AV_S16/256) (Unit = C) <Help> This Measure gives the maximum … |
| 1.3.6.1.4.1.20044.111.3.2 | Nodepm100gfmuxdMesrClient | |||
| 1.3.6.1.4.1.20044.111.3.2.16 | Tablepm100gfmuxdMesrclientTxTempTable | not-accessible | current | List of pm100gfmuxdMesrclientTxTemp Article |
| 1.3.6.1.4.1.20044.111.3.2.16.1 | Rowpm100gfmuxdMesrclientTxTempEntry | not-accessible | current | Row definition for the pm100gfmuxdMesrclientTxTemp table |
| 1.3.6.1.4.1.20044.111.3.2.16.1.1 | Columnpm100gfmuxdMesrclientTxTempIndex | read-only | current | Index definition for the pm100gfmuxdMesrclientTxTemp table |
| 1.3.6.1.4.1.20044.111.3.2.16.1.2 | Columnpm100gfmuxdMesrclientTxTempPortn | read-only | current | Client Trscv Temperature :This OID gives the Laser temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature … |
| 1.3.6.1.4.1.20044.111.3.2.48 | Tablepm100gfmuxdMesrclientTxBiasTable | not-accessible | current | List of pm100gfmuxdMesrclientTxBias Article |
| 1.3.6.1.4.1.20044.111.3.2.48.1 | Rowpm100gfmuxdMesrclientTxBiasEntry | not-accessible | current | Row definition for the pm100gfmuxdMesrclientTxBias table |
| 1.3.6.1.4.1.20044.111.3.2.48.1.1 | Columnpm100gfmuxdMesrclientTxBiasIndex | read-only | current | Index definition for the pm100gfmuxdMesrclientTxBias table |
| 1.3.6.1.4.1.20044.111.3.2.48.1.2 | Columnpm100gfmuxdMesrclientTxBiasPortn | read-only | current | Client Trscv Laser Bias :This OID gives the Laser bias value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV_U16/500) (… |
| 1.3.6.1.4.1.20044.111.3.2.80 | Tablepm100gfmuxdMesrclientTxPwrTable | not-accessible | current | List of pm100gfmuxdMesrclientTxPwr Article |
| 1.3.6.1.4.1.20044.111.3.2.80.1 | Rowpm100gfmuxdMesrclientTxPwrEntry | not-accessible | current | Row definition for the pm100gfmuxdMesrclientTxPwr table |
| 1.3.6.1.4.1.20044.111.3.2.80.1.1 | Columnpm100gfmuxdMesrclientTxPwrIndex | read-only | current | Index definition for the pm100gfmuxdMesrclientTxPwr table |
| 1.3.6.1.4.1.20044.111.3.2.80.1.2 | Columnpm100gfmuxdMesrclientTxPwrPortn | read-only | current | Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_… |
| 1.3.6.1.4.1.20044.111.3.2.112 | Tablepm100gfmuxdMesrclientRxPwrTable | not-accessible | current | List of pm100gfmuxdMesrclientRxPwr Article |
| 1.3.6.1.4.1.20044.111.3.2.112.1 | Rowpm100gfmuxdMesrclientRxPwrEntry | not-accessible | current | Row definition for the pm100gfmuxdMesrclientRxPwr table |
| 1.3.6.1.4.1.20044.111.3.2.112.1.1 | Columnpm100gfmuxdMesrclientRxPwrIndex | read-only | current | Index definition for the pm100gfmuxdMesrclientRxPwr table |
| 1.3.6.1.4.1.20044.111.3.2.112.1.2 | Columnpm100gfmuxdMesrclientRxPwrPortn | read-only | current | Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16… |
| 1.3.6.1.4.1.20044.111.3.2.416 | Tablepm100gfmuxdMesrclientTempMinTable | not-accessible | current | List of pm100gfmuxdMesrclientTempMin Article |
| 1.3.6.1.4.1.20044.111.3.2.416.1 | Rowpm100gfmuxdMesrclientTempMinEntry | not-accessible | current | Row definition for the pm100gfmuxdMesrclientTempMin table |
| 1.3.6.1.4.1.20044.111.3.2.416.1.1 | Columnpm100gfmuxdMesrclientTempMinIndex | read-only | current | Index definition for the pm100gfmuxdMesrclientTempMin table |
| 1.3.6.1.4.1.20044.111.3.2.416.1.2 | Columnpm100gfmuxdMesrclientTempMinPortn | read-only | current | Min Client Trscv Temperature :This OID gives the minimum temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temper… |
| 1.3.6.1.4.1.20044.111.3.2.448 | Tablepm100gfmuxdMesrclientTempMaxTable | not-accessible | current | List of pm100gfmuxdMesrclientTempMax Article |
| 1.3.6.1.4.1.20044.111.3.2.448.1 | Rowpm100gfmuxdMesrclientTempMaxEntry | not-accessible | current | Row definition for the pm100gfmuxdMesrclientTempMax table |
| 1.3.6.1.4.1.20044.111.3.2.448.1.1 | Columnpm100gfmuxdMesrclientTempMaxIndex | read-only | current | Index definition for the pm100gfmuxdMesrclientTempMax table |
| 1.3.6.1.4.1.20044.111.3.2.448.1.2 | Columnpm100gfmuxdMesrclientTempMaxPortn | read-only | current | Max Client Trscv Temperature :This OID gives the maximum temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temper… |
| 1.3.6.1.4.1.20044.111.3.3 | Nodepm100gfmuxdMesrLine | |||
| 1.3.6.1.4.1.20044.111.3.3.144 | Tablepm100gfmuxdMesrlineTxPwrMinTable | not-accessible | current | List of pm100gfmuxdMesrlineTxPwrMin Article |
| 1.3.6.1.4.1.20044.111.3.3.144.1 | Rowpm100gfmuxdMesrlineTxPwrMinEntry | not-accessible | current | Row definition for the pm100gfmuxdMesrlineTxPwrMin table |
| 1.3.6.1.4.1.20044.111.3.3.144.1.1 | Columnpm100gfmuxdMesrlineTxPwrMinIndex | read-only | current | Index definition for the pm100gfmuxdMesrlineTxPwrMin table |
| 1.3.6.1.4.1.20044.111.3.3.144.1.2 | Columnpm100gfmuxdMesrlineTxPwrMinPortn | read-only | current | Min Line Trscv Tx Power :This OID gives the minimum transmit power value among the network lanes of the Line Transceiver, read from the DDM (Digital Diagnostic… |
| 1.3.6.1.4.1.20044.111.3.3.160 | Tablepm100gfmuxdMesrlineTxCompositePwrTable | not-accessible | current | List of pm100gfmuxdMesrlineTxCompositePwr Article |
| 1.3.6.1.4.1.20044.111.3.3.160.1 | Rowpm100gfmuxdMesrlineTxCompositePwrEntry | not-accessible | current | Row definition for the pm100gfmuxdMesrlineTxCompositePwr table |
| 1.3.6.1.4.1.20044.111.3.3.160.1.1 | Columnpm100gfmuxdMesrlineTxCompositePwrIndex | read-only | current | Index definition for the pm100gfmuxdMesrlineTxCompositePwr table |
| 1.3.6.1.4.1.20044.111.3.3.160.1.2 | Columnpm100gfmuxdMesrlineTxCompositePwrPortn | read-only | current | Line Composite Tx Power (LR4/SR4) :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Line Transceiver, read from the… |
| 1.3.6.1.4.1.20044.111.3.3.176 | Tablepm100gfmuxdMesrlineRxPwrMinTable | not-accessible | current | List of pm100gfmuxdMesrlineRxPwrMin Article |
| 1.3.6.1.4.1.20044.111.3.3.176.1 | Rowpm100gfmuxdMesrlineRxPwrMinEntry | not-accessible | current | Row definition for the pm100gfmuxdMesrlineRxPwrMin table |
| 1.3.6.1.4.1.20044.111.3.3.176.1.1 | Columnpm100gfmuxdMesrlineRxPwrMinIndex | read-only | current | Index definition for the pm100gfmuxdMesrlineRxPwrMin table |
| 1.3.6.1.4.1.20044.111.3.3.176.1.2 | Columnpm100gfmuxdMesrlineRxPwrMinPortn | read-only | current | Min Line Trscv Rx Power :This OID gives the minimum receive power value among the network lanes of the Line Transceiver, read from the DDM (Digital Diagnostic … |
| 1.3.6.1.4.1.20044.111.3.3.192 | Tablepm100gfmuxdMesrlineRxCompositePwrTable | not-accessible | current | List of pm100gfmuxdMesrlineRxCompositePwr Article |
| 1.3.6.1.4.1.20044.111.3.3.192.1 | Rowpm100gfmuxdMesrlineRxCompositePwrEntry | not-accessible | current | Row definition for the pm100gfmuxdMesrlineRxCompositePwr table |
| 1.3.6.1.4.1.20044.111.3.3.192.1.1 | Columnpm100gfmuxdMesrlineRxCompositePwrIndex | read-only | current | Index definition for the pm100gfmuxdMesrlineRxCompositePwr table |
| 1.3.6.1.4.1.20044.111.3.3.192.1.2 | Columnpm100gfmuxdMesrlineRxCompositePwrPortn | read-only | current | Line Composite Rx Power (LR4/SR4) :This OID gives the composite receive power (sum of the network lanes receive power) of the Line Transceiver, read from the D… |
| 1.3.6.1.4.1.20044.111.3.3.208 | Tablepm100gfmuxdMesrlineTxPwrMaxTable | not-accessible | current | List of pm100gfmuxdMesrlineTxPwrMax Article |
| 1.3.6.1.4.1.20044.111.3.3.208.1 | Rowpm100gfmuxdMesrlineTxPwrMaxEntry | not-accessible | current | Row definition for the pm100gfmuxdMesrlineTxPwrMax table |
| 1.3.6.1.4.1.20044.111.3.3.208.1.1 | Columnpm100gfmuxdMesrlineTxPwrMaxIndex | read-only | current | Index definition for the pm100gfmuxdMesrlineTxPwrMax table |
| 1.3.6.1.4.1.20044.111.3.3.208.1.2 | Columnpm100gfmuxdMesrlineTxPwrMaxPortn | read-only | current | Max Line Trscv Tx Power :This OID gives the maximum transmit power value among the network lanes of the Line Transceiver, read from the DDM (Digital Diagnostic… |
| 1.3.6.1.4.1.20044.111.3.3.240 | Tablepm100gfmuxdMesrlineRxPwrMaxTable | not-accessible | current | List of pm100gfmuxdMesrlineRxPwrMax Article |
| 1.3.6.1.4.1.20044.111.3.3.240.1 | Rowpm100gfmuxdMesrlineRxPwrMaxEntry | not-accessible | current | Row definition for the pm100gfmuxdMesrlineRxPwrMax table |
| 1.3.6.1.4.1.20044.111.3.3.240.1.1 | Columnpm100gfmuxdMesrlineRxPwrMaxIndex | read-only | current | Index definition for the pm100gfmuxdMesrlineRxPwrMax table |
| 1.3.6.1.4.1.20044.111.3.3.240.1.2 | Columnpm100gfmuxdMesrlineRxPwrMaxPortn | read-only | current | Max Line Trscv Rx Power :This OID gives the maximum receive power value among the network lanes of the Line Transceiver, read in the DDM (Digital Diagnostic Mo… |
| 1.3.6.1.4.1.20044.111.4 | Nodepm100gfmuxdcounters | |||
| 1.3.6.1.4.1.20044.111.4.1 | Nodepm100gfmuxdCntOther | |||
| 1.3.6.1.4.1.20044.111.4.2 | Nodepm100gfmuxdCntClient | |||
| 1.3.6.1.4.1.20044.111.4.2.112 | Tablepm100gfmuxdCntclientInputErrorCounterTable | not-accessible | current | List of pm100gfmuxdCntclientInputErrorCounter Article |
| 1.3.6.1.4.1.20044.111.4.2.112.1 | Rowpm100gfmuxdCntclientInputErrorCounterEntry | not-accessible | current | Row definition for the pm100gfmuxdCntclientInputErrorCounter table |
| 1.3.6.1.4.1.20044.111.4.2.112.1.1 | Columnpm100gfmuxdCntclientInputErrorCounterIndex | read-only | current | Index definition for the pm100gfmuxdCntclientInputErrorCounter table |
| 1.3.6.1.4.1.20044.111.4.2.112.1.2 | Columnpm100gfmuxdCntclientInputErrorCounterValuePortn | read-only | current | Client Input Errors :This counter gives the number of SM-BIP8 (OTU4) or 66B/64B disparities (100GbE) on client port <Help> This counter gives the number of SM-… |
| 1.3.6.1.4.1.20044.111.4.2.112.1.3 | Columnpm100gfmuxdCntclientInputErrorCounterErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the BIP8 error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.111.4.2.112.1.4 | Columnpm100gfmuxdCntclientInputErrorCounterOverloadPortn | read-only | current | Client Counter Overload :This OID when set indicates a BIP8 error counter overload on Port |
| 1.3.6.1.4.1.20044.111.4.2.144 | Tablepm100gfmuxdCntclientCbipCounterTable | not-accessible | current | List of pm100gfmuxdCntclientCbipCounter Article |
| 1.3.6.1.4.1.20044.111.4.2.144.1 | Rowpm100gfmuxdCntclientCbipCounterEntry | not-accessible | current | Row definition for the pm100gfmuxdCntclientCbipCounter table |
| 1.3.6.1.4.1.20044.111.4.2.144.1.1 | Columnpm100gfmuxdCntclientCbipCounterIndex | read-only | current | Index definition for the pm100gfmuxdCntclientCbipCounter table |
| 1.3.6.1.4.1.20044.111.4.2.144.1.2 | Columnpm100gfmuxdCntclientCbipCounterValuePortn | read-only | current | Client Output Errors :This counter gives the number of SM-BIP8 (OTU4) or 66B/64B disparities (100GbE) on client port <Help> This counter gives the number of SM… |
| 1.3.6.1.4.1.20044.111.4.2.144.1.3 | Columnpm100gfmuxdCntclientCbipCounterErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the BIP8 error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.111.4.2.144.1.4 | Columnpm100gfmuxdCntclientCbipCounterOverloadPortn | read-only | current | Client CBIP Counter Overload :This OID when set indicates a BIP8 error counter overload on Port |
| 1.3.6.1.4.1.20044.111.4.3 | Nodepm100gfmuxdCntLine | |||
| 1.3.6.1.4.1.20044.111.4.3.192 | Tablepm100gfmuxdCntlocalLineSmBip8ErrorCounterTable | not-accessible | current | List of pm100gfmuxdCntlocalLineSmBip8ErrorCounter Article |
| 1.3.6.1.4.1.20044.111.4.3.192.1 | Rowpm100gfmuxdCntlocalLineSmBip8ErrorCounterEntry | not-accessible | current | Row definition for the pm100gfmuxdCntlocalLineSmBip8ErrorCounter table |
| 1.3.6.1.4.1.20044.111.4.3.192.1.1 | Columnpm100gfmuxdCntlocalLineSmBip8ErrorCounterIndex | read-only | current | Index definition for the pm100gfmuxdCntlocalLineSmBip8ErrorCounter table |
| 1.3.6.1.4.1.20044.111.4.3.192.1.2 | Columnpm100gfmuxdCntlocalLineSmBip8ErrorCounterValuePortn | read-only | current | Line SM BIP8 Errors :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC <Help> This counter gives the current Bit Error Rate (residua… |
| 1.3.6.1.4.1.20044.111.4.3.192.1.3 | Columnpm100gfmuxdCntlocalLineSmBip8ErrorCounterErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the B1 error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.111.4.3.192.1.4 | Columnpm100gfmuxdCntlocalLineSmBip8ErrorCounterOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a B1 error counter overload on Port |
| 1.3.6.1.4.1.20044.111.4.3.193 | Tablepm100gfmuxdCntlocalLineFecCorrectedErrorsCounterTable | not-accessible | current | List of pm100gfmuxdCntlocalLineFecCorrectedErrorsCounter Article |
| 1.3.6.1.4.1.20044.111.4.3.193.1 | Rowpm100gfmuxdCntlocalLineFecCorrectedErrorsCounterEntry | not-accessible | current | Row definition for the pm100gfmuxdCntlocalLineFecCorrectedErrorsCounter table |
| 1.3.6.1.4.1.20044.111.4.3.193.1.1 | Columnpm100gfmuxdCntlocalLineFecCorrectedErrorsCounterIndex | read-only | current | Index definition for the pm100gfmuxdCntlocalLineFecCorrectedErrorsCounter table |
| 1.3.6.1.4.1.20044.111.4.3.193.1.2 | Columnpm100gfmuxdCntlocalLineFecCorrectedErrorsCounterValuePortn | read-only | current | Line Input HD FEC Corrected Errors :This OID gives the current Bit Error Rate before the Hard Decision FEC <Help> This counter gives the current Bit Error Rate… |
| 1.3.6.1.4.1.20044.111.4.3.193.1.3 | Columnpm100gfmuxdCntlocalLineFecCorrectedErrorsCounterErrorPortn | read-only | current | FEC Counter Error :This bit when set indicates the FEC corrected errors counter value is invalid on Line |
| 1.3.6.1.4.1.20044.111.4.3.193.1.4 | Columnpm100gfmuxdCntlocalLineFecCorrectedErrorsCounterOverloadPortn | read-only | current | FEC Counter Overload :This bit when set indicates a FEC corrected errors counter overload on Line |
| 1.3.6.1.4.1.20044.111.4.3.194 | Tablepm100gfmuxdCntremoteLineSmBip8ErrorCounterTable | not-accessible | current | List of pm100gfmuxdCntremoteLineSmBip8ErrorCounter Article |
| 1.3.6.1.4.1.20044.111.4.3.194.1 | Rowpm100gfmuxdCntremoteLineSmBip8ErrorCounterEntry | not-accessible | current | Row definition for the pm100gfmuxdCntremoteLineSmBip8ErrorCounter table |
| 1.3.6.1.4.1.20044.111.4.3.194.1.1 | Columnpm100gfmuxdCntremoteLineSmBip8ErrorCounterIndex | read-only | current | Index definition for the pm100gfmuxdCntremoteLineSmBip8ErrorCounter table |
| 1.3.6.1.4.1.20044.111.4.3.194.1.2 | Columnpm100gfmuxdCntremoteLineSmBip8ErrorCounterValuePortn | read-only | current | Remote SM BIP8 :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC on the remote side <Help> This counter gives the current Bit Error… |
| 1.3.6.1.4.1.20044.111.4.3.194.1.3 | Columnpm100gfmuxdCntremoteLineSmBip8ErrorCounterErrorPortn | read-only | current | Remote Counter Error : |
| 1.3.6.1.4.1.20044.111.4.3.194.1.4 | Columnpm100gfmuxdCntremoteLineSmBip8ErrorCounterOverloadPortn | read-only | current | Remote Counter Overload : |
| 1.3.6.1.4.1.20044.111.4.3.195 | Tablepm100gfmuxdCntlineDfrmTimCntTable | not-accessible | current | List of pm100gfmuxdCntlineDfrmTimCnt Article |
| 1.3.6.1.4.1.20044.111.4.3.195.1 | Rowpm100gfmuxdCntlineDfrmTimCntEntry | not-accessible | current | Row definition for the pm100gfmuxdCntlineDfrmTimCnt table |
| 1.3.6.1.4.1.20044.111.4.3.195.1.1 | Columnpm100gfmuxdCntlineDfrmTimCntIndex | read-only | current | Index definition for the pm100gfmuxdCntlineDfrmTimCnt table |
| 1.3.6.1.4.1.20044.111.4.3.195.1.2 | Columnpm100gfmuxdCntlineDfrmTimCntValuePortn | read-only | current | Line Timer Counter : |
| 1.3.6.1.4.1.20044.111.4.3.195.1.3 | Columnpm100gfmuxdCntlineDfrmTimCntErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.111.4.3.195.1.4 | Columnpm100gfmuxdCntlineDfrmTimCntOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.111.4.3.196 | Tablepm100gfmuxdCntlocalLineTrscvPreSdFecErrorCounterTable | not-accessible | current | List of pm100gfmuxdCntlocalLineTrscvPreSdFecErrorCounter Article |
| 1.3.6.1.4.1.20044.111.4.3.196.1 | Rowpm100gfmuxdCntlocalLineTrscvPreSdFecErrorCounterEntry | not-accessible | current | Row definition for the pm100gfmuxdCntlocalLineTrscvPreSdFecErrorCounter table |
| 1.3.6.1.4.1.20044.111.4.3.196.1.1 | Columnpm100gfmuxdCntlocalLineTrscvPreSdFecErrorCounterIndex | read-only | current | Index definition for the pm100gfmuxdCntlocalLineTrscvPreSdFecErrorCounter table |
| 1.3.6.1.4.1.20044.111.4.3.196.1.2 | Columnpm100gfmuxdCntlocalLineTrscvPreSdFecErrorCounterValuePortn | read-only | current | Line Pre FEC Errors :This OID gives the current Bit Error Rate before the FEC <Help> This counter gives the current Bit Error Rate before the FEC |
| 1.3.6.1.4.1.20044.111.4.3.196.1.3 | Columnpm100gfmuxdCntlocalLineTrscvPreSdFecErrorCounterErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.111.4.3.196.1.4 | Columnpm100gfmuxdCntlocalLineTrscvPreSdFecErrorCounterOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.111.4.3.197 | Tablepm100gfmuxdCntlocalLineTrscvUncorrectedSdFecErrorCounterTable | not-accessible | current | List of pm100gfmuxdCntlocalLineTrscvUncorrectedSdFecErrorCounter Article |
| 1.3.6.1.4.1.20044.111.4.3.197.1 | Rowpm100gfmuxdCntlocalLineTrscvUncorrectedSdFecErrorCounterEntry | not-accessible | current | Row definition for the pm100gfmuxdCntlocalLineTrscvUncorrectedSdFecErrorCounter table |
| 1.3.6.1.4.1.20044.111.4.3.197.1.1 | Columnpm100gfmuxdCntlocalLineTrscvUncorrectedSdFecErrorCounterIndex | read-only | current | Index definition for the pm100gfmuxdCntlocalLineTrscvUncorrectedSdFecErrorCounter table |
| 1.3.6.1.4.1.20044.111.4.3.197.1.2 | Columnpm100gfmuxdCntlocalLineTrscvUncorrectedSdFecErrorCounterValuePortn | read-only | current | Uncorrected FEC Errors :This OID gives the current Bit Error Rate after the Soft Decision FEC (residual) <Help> This counter gives the current Bit Error Rate a… |
| 1.3.6.1.4.1.20044.111.4.3.197.1.3 | Columnpm100gfmuxdCntlocalLineTrscvUncorrectedSdFecErrorCounterErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.111.4.3.197.1.4 | Columnpm100gfmuxdCntlocalLineTrscvUncorrectedSdFecErrorCounterOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.111.4.3.198 | Tablepm100gfmuxdCntlocalLineTrscvPreSdFecBitCounterTable | not-accessible | current | List of pm100gfmuxdCntlocalLineTrscvPreSdFecBitCounter Article |
| 1.3.6.1.4.1.20044.111.4.3.198.1 | Rowpm100gfmuxdCntlocalLineTrscvPreSdFecBitCounterEntry | not-accessible | current | Row definition for the pm100gfmuxdCntlocalLineTrscvPreSdFecBitCounter table |
| 1.3.6.1.4.1.20044.111.4.3.198.1.1 | Columnpm100gfmuxdCntlocalLineTrscvPreSdFecBitCounterIndex | read-only | current | Index definition for the pm100gfmuxdCntlocalLineTrscvPreSdFecBitCounter table |
| 1.3.6.1.4.1.20044.111.4.3.198.1.2 | Columnpm100gfmuxdCntlocalLineTrscvPreSdFecBitCounterValuePortn | read-only | current | Pre-SD FEC Bit Counter :This OID gives the current Bit count before the Soft Decision FEC <Help> This counter gives the current Bit Count before the Soft Decis… |
| 1.3.6.1.4.1.20044.111.4.3.198.1.3 | Columnpm100gfmuxdCntlocalLineTrscvPreSdFecBitCounterErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.111.4.3.198.1.4 | Columnpm100gfmuxdCntlocalLineTrscvPreSdFecBitCounterOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.111.4.3.199 | Tablepm100gfmuxdCntlocalLineTrscvUncorrectedSdFecBitCounterTable | not-accessible | current | List of pm100gfmuxdCntlocalLineTrscvUncorrectedSdFecBitCounter Article |
| 1.3.6.1.4.1.20044.111.4.3.199.1 | Rowpm100gfmuxdCntlocalLineTrscvUncorrectedSdFecBitCounterEntry | not-accessible | current | Row definition for the pm100gfmuxdCntlocalLineTrscvUncorrectedSdFecBitCounter table |
| 1.3.6.1.4.1.20044.111.4.3.199.1.1 | Columnpm100gfmuxdCntlocalLineTrscvUncorrectedSdFecBitCounterIndex | read-only | current | Index definition for the pm100gfmuxdCntlocalLineTrscvUncorrectedSdFecBitCounter table |
| 1.3.6.1.4.1.20044.111.4.3.199.1.2 | Columnpm100gfmuxdCntlocalLineTrscvUncorrectedSdFecBitCounterValuePortn | read-only | current | Uncorrected SD FEC Bit Counter :This OID gives the current Bit count after the Soft Decision FEC (residual) <Help> This counter gives the current Bit Count aft… |
| 1.3.6.1.4.1.20044.111.4.3.199.1.3 | Columnpm100gfmuxdCntlocalLineTrscvUncorrectedSdFecBitCounterErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.111.4.3.199.1.4 | Columnpm100gfmuxdCntlocalLineTrscvUncorrectedSdFecBitCounterOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.111.6 | Nodepm100gfmuxdcontrolsWrite | |||
| 1.3.6.1.4.1.20044.111.6.1 | Nodepm100gfmuxdCtrlOther | |||
| 1.3.6.1.4.1.20044.111.6.1.1 | Nodepm100gfmuxdCtrlconfMgnt1 | |||
| 1.3.6.1.4.1.20044.111.6.1.1.1 | Scalarpm100gfmuxdCtrlConf1Load1 | read-write | current | Load Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM. |
| 1.3.6.1.4.1.20044.111.6.1.1.2 | Scalarpm100gfmuxdCtrlConf2Load1 | read-write | current | Load Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM. |
| 1.3.6.1.4.1.20044.111.6.1.1.10 | Scalarpm100gfmuxdCtrlConf2Flash1 | read-write | current | Write Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura… |
| 1.3.6.1.4.1.20044.111.6.1.1.14 | Scalarpm100gfmuxdCtrlConf2Clear1 | read-write | current | Clear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o… |
| 1.3.6.1.4.1.20044.111.6.1.4 | Nodepm100gfmuxdCtrlsynth4 | |||
| 1.3.6.1.4.1.20044.111.6.1.4.1 | Scalarpm100gfmuxdCtrlCorrelatOn | read-write | current | Enable Alarm Correlation :This OID enables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.111.6.1.4.2 | Scalarpm100gfmuxdCtrlCorrelatOff | read-write | current | Disable Alarm Correlation :This OID disables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.111.6.1.5 | Nodepm100gfmuxdCtrlswMgnt | |||
| 1.3.6.1.4.1.20044.111.6.1.5.2 | Scalarpm100gfmuxdCtrlColdReset | read-write | current | PM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> … |
| 1.3.6.1.4.1.20044.111.6.1.5.3 | Scalarpm100gfmuxdCtrlWarmReset | read-write | current | PM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th… |
| 1.3.6.1.4.1.20044.111.6.1.5.5 | Scalarpm100gfmuxdCtrlLoadSwBank1 | read-write | current | Set Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW… |
| 1.3.6.1.4.1.20044.111.6.1.5.6 | Scalarpm100gfmuxdCtrlLoadSwBank2 | read-write | current | Set Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S… |
| 1.3.6.1.4.1.20044.111.6.1.6 | Nodepm100gfmuxdCtrlgwMgnt | |||
| 1.3.6.1.4.1.20044.111.6.1.6.1 | Scalarpm100gfmuxdCtrlCurrentGwReset | read-write | current | Active Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting. |
| 1.3.6.1.4.1.20044.111.6.1.6.5 | Scalarpm100gfmuxdCtrlLoadGwBank1 | read-write | current | Set Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.111.6.1.6.6 | Scalarpm100gfmuxdCtrlLoadGwBank2 | read-write | current | Set Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.111.6.1.6.7 | Scalarpm100gfmuxdCtrlLoadGwBank3 | read-write | current | Set Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.111.6.1.6.8 | Scalarpm100gfmuxdCtrlLoadGwBank4 | read-write | current | Set Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.111.6.1.192 | Nodepm100gfmuxdCtrlledTest | |||
| 1.3.6.1.4.1.20044.111.6.1.192.1 | Scalarpm100gfmuxdCtrlGreenLed | read-write | current | Green Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green |
| 1.3.6.1.4.1.20044.111.6.1.192.2 | Scalarpm100gfmuxdCtrlRedLed | read-write | current | Red Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red |
| 1.3.6.1.4.1.20044.111.6.1.192.3 | Scalarpm100gfmuxdCtrlLedOff | read-write | current | Leds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF |
| 1.3.6.1.4.1.20044.111.6.1.201 | Nodepm100gfmuxdCtrlinitSwitchMarvell | |||
| 1.3.6.1.4.1.20044.111.6.1.201.1 | Scalarpm100gfmuxdCtrlInitSwitchMarvell | read-write | current | Switch Initialization :This OID operates an initialization of the switch managed through the module <Help> This control activates an initialization of the swit… |
| 1.3.6.1.4.1.20044.111.6.1.259 | Nodepm100gfmuxdCtrlresetCount | |||
| 1.3.6.1.4.1.20044.111.6.1.259.1 | Scalarpm100gfmuxdCtrlResetcount | read-write | current | Module Count Global Reset :This OID resets all the errors counters on the module <Help > This control initiates a reset of the errors counters on the module |
| 1.3.6.1.4.1.20044.111.6.1.260 | Nodepm100gfmuxdCtrlresetRmon | |||
| 1.3.6.1.4.1.20044.111.6.1.260.1 | Scalarpm100gfmuxdCtrlResetrmon | read-write | current | Module Rmon Global Reset :This OID resets all the Rmon counters on the module <Help > This control initiates a reset of the Rmon counters on the module |
| 1.3.6.1.4.1.20044.111.6.1.261 | Nodepm100gfmuxdCtrlresetMeasurements | |||
| 1.3.6.1.4.1.20044.111.6.1.261.1 | Scalarpm100gfmuxdCtrlResetmeasurements | read-write | current | Management Meas Global Reset :This OID resets some measurements on the management <Help > This control initiates a reset of some measurements on the management |
| 1.3.6.1.4.1.20044.111.6.2 | Nodepm100gfmuxdCtrlClient | |||
| 1.3.6.1.4.1.20044.111.6.2.16 | Tablepm100gfmuxdCtrlaccessLoopTable | not-accessible | current | List of pm100gfmuxdCtrlaccessLoop Article |
| 1.3.6.1.4.1.20044.111.6.2.16.1 | Rowpm100gfmuxdCtrlaccessLoopEntry | not-accessible | current | Row definition for the pm100gfmuxdCtrlaccessLoop table |
| 1.3.6.1.4.1.20044.111.6.2.16.1.1 | Columnpm100gfmuxdCtrlaccessLoopIndex | read-only | current | Index definition for the pm100gfmuxdCtrlaccessLoop table |
| 1.3.6.1.4.1.20044.111.6.2.16.1.2 | Columnpm100gfmuxdCtrlaccessLoopPortn | read-write | current | Client Facility Loopback :This OID, when set at '1' puts the client port in loopback, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. <Help… |
| 1.3.6.1.4.1.20044.111.6.2.17 | Tablepm100gfmuxdCtrlclientLoopToLineTable | not-accessible | current | List of pm100gfmuxdCtrlclientLoopToLine Article |
| 1.3.6.1.4.1.20044.111.6.2.17.1 | Rowpm100gfmuxdCtrlclientLoopToLineEntry | not-accessible | current | Row definition for the pm100gfmuxdCtrlclientLoopToLine table |
| 1.3.6.1.4.1.20044.111.6.2.17.1.1 | Columnpm100gfmuxdCtrlclientLoopToLineIndex | read-only | current | Index definition for the pm100gfmuxdCtrlclientLoopToLine table |
| 1.3.6.1.4.1.20044.111.6.2.17.1.2 | Columnpm100gfmuxdCtrlclientLoopToLinePortn | read-write | current | Client Terminal Loopback :This OID, when set, puts the client port in loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.<Help> This control ena… |
| 1.3.6.1.4.1.20044.111.6.2.21 | Tablepm100gfmuxdCtrlcsfUpInsTable | not-accessible | current | List of pm100gfmuxdCtrlcsfUpIns Article |
| 1.3.6.1.4.1.20044.111.6.2.21.1 | Rowpm100gfmuxdCtrlcsfUpInsEntry | not-accessible | current | Row definition for the pm100gfmuxdCtrlcsfUpIns table |
| 1.3.6.1.4.1.20044.111.6.2.21.1.1 | Columnpm100gfmuxdCtrlcsfUpInsIndex | read-only | current | Index definition for the pm100gfmuxdCtrlcsfUpIns table |
| 1.3.6.1.4.1.20044.111.6.2.21.1.2 | Columnpm100gfmuxdCtrlcsfUpInsPortn | read-write | current | Client Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo… |
| 1.3.6.1.4.1.20044.111.6.2.22 | Tablepm100gfmuxdCtrlcaisDwInsTable | not-accessible | current | List of pm100gfmuxdCtrlcaisDwIns Article |
| 1.3.6.1.4.1.20044.111.6.2.22.1 | Rowpm100gfmuxdCtrlcaisDwInsEntry | not-accessible | current | Row definition for the pm100gfmuxdCtrlcaisDwIns table |
| 1.3.6.1.4.1.20044.111.6.2.22.1.1 | Columnpm100gfmuxdCtrlcaisDwInsIndex | read-only | current | Index definition for the pm100gfmuxdCtrlcaisDwIns table |
| 1.3.6.1.4.1.20044.111.6.2.22.1.2 | Columnpm100gfmuxdCtrlcaisDwInsPortn | read-write | current | Client AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port |
| 1.3.6.1.4.1.20044.111.6.2.262 | Tablepm100gfmuxdCtrlclientResetAllCountTable | not-accessible | current | List of pm100gfmuxdCtrlclientResetAllCount Article |
| 1.3.6.1.4.1.20044.111.6.2.262.1 | Rowpm100gfmuxdCtrlclientResetAllCountEntry | not-accessible | current | Row definition for the pm100gfmuxdCtrlclientResetAllCount table |
| 1.3.6.1.4.1.20044.111.6.2.262.1.1 | Columnpm100gfmuxdCtrlclientResetAllCountIndex | read-only | current | Index definition for the pm100gfmuxdCtrlclientResetAllCount table |
| 1.3.6.1.4.1.20044.111.6.2.262.1.2 | Columnpm100gfmuxdCtrlclientResetAllCountsPortn | read-write | current | Client Counters Reset :This OID resets every counter on the client port <Help> This control operates a reset on the statistics current ,previous and history cl… |
| 1.3.6.1.4.1.20044.111.6.3 | Nodepm100gfmuxdCtrlLine | |||
| 1.3.6.1.4.1.20044.111.6.3.64 | Tablepm100gfmuxdCtrlcommAccessLoopTable | not-accessible | current | List of pm100gfmuxdCtrlcommAccessLoop Article |
| 1.3.6.1.4.1.20044.111.6.3.64.1 | Rowpm100gfmuxdCtrlcommAccessLoopEntry | not-accessible | current | Row definition for the pm100gfmuxdCtrlcommAccessLoop table |
| 1.3.6.1.4.1.20044.111.6.3.64.1.1 | Columnpm100gfmuxdCtrlcommAccessLoopIndex | read-only | current | Index definition for the pm100gfmuxdCtrlcommAccessLoop table |
| 1.3.6.1.4.1.20044.111.6.3.64.1.2 | Columnpm100gfmuxdCtrlcommAccessLoopPortn | read-write | current | Line Terminal Loopback :This OID, when set, puts the module in common access loopback, looping the 100 Gb/s output signal on the 100 Gb/s input.<Help> This con… |
| 1.3.6.1.4.1.20044.111.6.3.66 | Tablepm100gfmuxdCtrllineLoopTable | not-accessible | current | List of pm100gfmuxdCtrllineLoop Article |
| 1.3.6.1.4.1.20044.111.6.3.66.1 | Rowpm100gfmuxdCtrllineLoopEntry | not-accessible | current | Row definition for the pm100gfmuxdCtrllineLoop table |
| 1.3.6.1.4.1.20044.111.6.3.66.1.1 | Columnpm100gfmuxdCtrllineLoopIndex | read-only | current | Index definition for the pm100gfmuxdCtrllineLoop table |
| 1.3.6.1.4.1.20044.111.6.3.66.1.2 | Columnpm100gfmuxdCtrllineLoopPortn | read-write | current | Line Facility Loopback :This OID, when set at '1' puts the module in line loopback mode, looping the received 100 Gb/s signal on the transmit 100 Gb/s output. … |
| 1.3.6.1.4.1.20044.111.6.3.263 | Tablepm100gfmuxdCtrllineResetAllCountTable | not-accessible | current | List of pm100gfmuxdCtrllineResetAllCount Article |
| 1.3.6.1.4.1.20044.111.6.3.263.1 | Rowpm100gfmuxdCtrllineResetAllCountEntry | not-accessible | current | Row definition for the pm100gfmuxdCtrllineResetAllCount table |
| 1.3.6.1.4.1.20044.111.6.3.263.1.1 | Columnpm100gfmuxdCtrllineResetAllCountIndex | read-only | current | Index definition for the pm100gfmuxdCtrllineResetAllCount table |
| 1.3.6.1.4.1.20044.111.6.3.263.1.2 | Columnpm100gfmuxdCtrllineResetAllCountsPortn | read-write | current | Line Counters Reset :This OID resets every counter on the line port <Help> This control operates a reset on the statistics current ,previous and history line p… |
| 1.3.6.1.4.1.20044.111.7 | Nodepm100gfmuxdri | |||
| 1.3.6.1.4.1.20044.111.7.1 | Nodepm100gfmuxdriTable | |||
| 1.3.6.1.4.1.20044.111.7.1.1 | Tablepm100gfmuxdRinvSfpTable | not-accessible | current | List of the SFPs on the selected module |
| 1.3.6.1.4.1.20044.111.7.1.1.1 | Rowpm100gfmuxdRinvSfpEntry | not-accessible | current | Row definition for the SFP table |
| 1.3.6.1.4.1.20044.111.7.1.1.1.1 | Columnpm100gfmuxdRinvSfpIndex | read-only | current | Index for SFP table |
| 1.3.6.1.4.1.20044.111.7.1.1.1.2 | Columnpm100gfmuxdRinvsfp | read-only | current | Inventory for the SFP: This OID contains the inventory for the SFP |
| 1.3.6.1.4.1.20044.111.7.1.2 | Tablepm100gfmuxdRinvLineTable | not-accessible | current | List of the XFPs on the selected module |
| 1.3.6.1.4.1.20044.111.7.1.2.1 | Rowpm100gfmuxdRinvLineEntry | not-accessible | current | Row definition for the XFP table |
| 1.3.6.1.4.1.20044.111.7.1.2.1.1 | Columnpm100gfmuxdRinvLineIndex | read-only | current | Index for XFP table |
| 1.3.6.1.4.1.20044.111.7.1.2.1.2 | Columnpm100gfmuxdRinvxfpLine | read-only | current | Inventory for the XFP: This OID contains the inventory for the XFP |
| 1.3.6.1.4.1.20044.111.7.2 | Scalarpm100gfmuxdRinvReloadInventory | read-write | current | Reload the inventory: This OID triggers an inventory reload. |
| 1.3.6.1.4.1.20044.111.7.3 | Scalarpm100gfmuxdRinvHwPlatform | read-only | current | HW platform description: This OID contains the description of the Hardware platform. |
| 1.3.6.1.4.1.20044.111.7.4 | Scalarpm100gfmuxdRinvModulePlatform | read-only | current | Module platform description: This OID contains the description of the Module. |
| 1.3.6.1.4.1.20044.111.7.5 | Scalarpm100gfmuxdRinvSwPlatform | read-only | current | SW platform description: This OID contains the description of the Software platform. |
| 1.3.6.1.4.1.20044.111.7.6 | Scalarpm100gfmuxdRinvGwPlatform | read-only | current | GW platform description: This OID contains the description of the Gateware platform. |
| 1.3.6.1.4.1.20044.111.8 | Nodepm100gfmuxddownload | |||
| 1.3.6.1.4.1.20044.111.8.1 | Nodepm100gfmuxdDwlOther | |||
| 1.3.6.1.4.1.20044.111.8.1.0 | Nodepm100gfmuxdDwlrestartProcess | |||
| 1.3.6.1.4.1.20044.111.8.1.0.1 | Scalarpm100gfmuxdDwlWarmRestartProcessed | read-only | current | Warm Restart :This OID indicates that the module last restart was a Warm RESTART |
| 1.3.6.1.4.1.20044.111.8.1.0.2 | Scalarpm100gfmuxdDwlColdRestartProcessed | read-only | current | Cold Restart :This OID indicates that the module last restart was a Cold RESTART |
| 1.3.6.1.4.1.20044.111.8.1.1 | Nodepm100gfmuxdDwlswBanksUsed | |||
| 1.3.6.1.4.1.20044.111.8.1.1.1 | Scalarpm100gfmuxdDwlSwBank1Used | read-only | current | SW Bank 1 Active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.111.8.1.1.2 | Scalarpm100gfmuxdDwlSwBank2Used | read-only | current | SW Bank 2 Active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby |
| 1.3.6.1.4.1.20044.111.8.1.1.5 | Scalarpm100gfmuxdDwlSwBank1Notempty | read-only | current | SW Bank 1 Loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package |
| 1.3.6.1.4.1.20044.111.8.1.1.6 | Scalarpm100gfmuxdDwlSwBank2Notempty | read-only | current | SW Bank 2 Loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package |
| 1.3.6.1.4.1.20044.111.8.1.2 | Nodepm100gfmuxdDwlgwBanksUsed | |||
| 1.3.6.1.4.1.20044.111.8.1.2.1 | Scalarpm100gfmuxdDwlGwBank1Used | read-only | current | GW Bank 1 Active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.111.8.1.2.2 | Scalarpm100gfmuxdDwlGwBank2Used | read-only | current | GW Bank 2 Active :This OID indicates the module is working on GW bank 2 |
| 1.3.6.1.4.1.20044.111.8.1.2.3 | Scalarpm100gfmuxdDwlGwBank3Used | read-only | current | GW Bank 3 Active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby |
| 1.3.6.1.4.1.20044.111.8.1.2.4 | Scalarpm100gfmuxdDwlGwBank4Used | read-only | current | GW Bank 4 Active :This OID indicates the module is working on GW bank 4 |
| 1.3.6.1.4.1.20044.111.8.1.2.5 | Scalarpm100gfmuxdDwlGwBank1Notempty | read-only | current | GW Bank 1 Loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package |
| 1.3.6.1.4.1.20044.111.8.1.2.6 | Scalarpm100gfmuxdDwlGwBank2Notempty | read-only | current | GW Bank 2 Loaded :This OID indicates a gateware is loaded in GW bank 2 |
| 1.3.6.1.4.1.20044.111.8.1.2.7 | Scalarpm100gfmuxdDwlGwBank3Notempty | read-only | current | GW Bank 3 Loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package |
| 1.3.6.1.4.1.20044.111.8.1.2.8 | Scalarpm100gfmuxdDwlGwBank4Notempty | read-only | current | GW Bank 4 Loaded :This OID indicates a gateware is loaded in GW bank 4 |
| 1.3.6.1.4.1.20044.111.8.2 | Nodepm100gfmuxdDwlClient | |||
| 1.3.6.1.4.1.20044.111.8.3 | Nodepm100gfmuxdDwlLine | |||
| 1.3.6.1.4.1.20044.111.9 | Nodepm100gfmuxdConfig | |||
| 1.3.6.1.4.1.20044.111.9.1 | Nodepm100gfmuxdCfgAccessCAisCsf | |||
| 1.3.6.1.4.1.20044.111.9.1.1 | Tablepm100gfmuxdCfgClientcaiscsfTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.111.9.1.1.1 | Rowpm100gfmuxdCfgClientcaiscsfEntry | not-accessible | current | Row definition for the accessCAisCsf table |
| 1.3.6.1.4.1.20044.111.9.1.1.1.1 | Columnpm100gfmuxdCfgClientcaiscsfIndex | read-only | current | Index definition for the clientcaiscsf table |
| 1.3.6.1.4.1.20044.111.9.1.1.1.3 | Columnpm100gfmuxdCfgReservePortn | read-write | current | CAIS mode on Client Port :This register enables/disables port laser shutdown on CAIS insertion condition |
| 1.3.6.1.4.1.20044.111.9.2 | Nodepm100gfmuxdCfgStartup | |||
| 1.3.6.1.4.1.20044.111.9.2.1 | Tablepm100gfmuxdCfgClientStartupTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.111.9.2.1.1 | Rowpm100gfmuxdCfgClientStartupEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.111.9.2.1.1.1 | Columnpm100gfmuxdCfgClientStartupIndex | read-only | current | Index definition for the clientStartup table |
| 1.3.6.1.4.1.20044.111.9.2.1.1.3 | Columnpm100gfmuxdCfgSystConfPortPortn | read-write | current | Default Settings on Client Port :This register configures the default initialisation settings on the port. |
| 1.3.6.1.4.1.20044.111.9.2.1.1.4 | Columnpm100gfmuxdCfgNetConfPortPortn | read-write | current | Default Settings on Client Port :This register configures the default initialisation settings on the port. |
| 1.3.6.1.4.1.20044.111.9.2.1.1.14 | Columnpm100gfmuxdCfgOptionsPortPortn | read-write | current | Default Options on Client Port :This register configures the default options on the port. |
| 1.3.6.1.4.1.20044.111.9.2.2 | Tablepm100gfmuxdCfgLineStartupThreshTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.111.9.2.2.1 | Rowpm100gfmuxdCfgLineStartupThreshEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.111.9.2.2.1.1 | Columnpm100gfmuxdCfgLineStartupThreshIndex | read-only | current | Index definition for the lineStartupThresh table |
| 1.3.6.1.4.1.20044.111.9.2.2.1.3 | Columnpm100gfmuxdCfgSystConfLinePortn | read-write | current | Default Settings on Line :This register configures the default initialisation settings on Line |
| 1.3.6.1.4.1.20044.111.9.2.2.1.14 | Columnpm100gfmuxdCfgOptionsLinePortn | read-write | current | Default Options on Line :This register configures the default options on the line |
| 1.3.6.1.4.1.20044.111.9.2.3 | Tablepm100gfmuxdCfgLineStartupTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.111.9.2.3.1 | Rowpm100gfmuxdCfgLineStartupEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.111.9.2.3.1.1 | Columnpm100gfmuxdCfgLineStartupIndex | read-only | current | Index definition for the lineStartup table |
| 1.3.6.1.4.1.20044.111.9.2.3.1.3 | Columnpm100gfmuxdCfgSystConfMsaLinePortn | read-write | current | Default settings on TRX :This register configures the default initialisation settings on TRX |
| 1.3.6.1.4.1.20044.111.9.2.3.1.6 | Columnpm100gfmuxdCfgLineInputPowerHighAlarmPortn | read-write | deprecated | Default settings on alarm threshold :This register configures the default initialisation settings on a threshold |
| 1.3.6.1.4.1.20044.111.9.2.3.1.7 | Columnpm100gfmuxdCfgLineInputPowerHighWarningPortn | read-write | deprecated | Default settings on warning threshold :This register configures the default initialisation settings on a threshold |
| 1.3.6.1.4.1.20044.111.9.2.3.1.8 | Columnpm100gfmuxdCfgLineInputPowerLowWarningPortn | read-write | deprecated | Default settings on warning threshold :This register configures the default initialisation settings on a threshold |
| 1.3.6.1.4.1.20044.111.9.2.3.1.9 | Columnpm100gfmuxdCfgLineInputPowerLowAlarmPortn | read-write | deprecated | Default settings on alarm threshold :This register configures the default initialisation settings on a threshold |
| 1.3.6.1.4.1.20044.111.9.2.3.1.10 | Columnpm100gfmuxdCfgLineOutputPowerHighAlarmPortn | read-write | deprecated | Default settings on alarm threshold :This register configures the default initialisation settings on a threshold |
| 1.3.6.1.4.1.20044.111.9.2.3.1.11 | Columnpm100gfmuxdCfgLineOutputPowerHighWarningPortn | read-write | deprecated | Default settings on warning threshold :This register configures the default initialisation settings on a threshold |
| 1.3.6.1.4.1.20044.111.9.2.3.1.12 | Columnpm100gfmuxdCfgLineOutputPowerLowWarningPortn | read-write | deprecated | Default settings on warning threshold :This register configures the default initialisation settings on a threshold |
| 1.3.6.1.4.1.20044.111.9.2.3.1.13 | Columnpm100gfmuxdCfgLineOutputPowerLowAlarmPortn | read-write | deprecated | Default settings on alarm threshold :This register configures the default initialisation settings on a threshold |
| 1.3.6.1.4.1.20044.111.9.2.3.1.14 | Columnpm100gfmuxdCfgLineLossOfSignalPortn | read-write | deprecated | Default settings on Los threshold :This register configures the default initialisation settings on a threshold |
| 1.3.6.1.4.1.20044.111.9.3 | Nodepm100gfmuxdCfgLabels | |||
| 1.3.6.1.4.1.20044.111.9.3.1 | Tablepm100gfmuxdCfgLabelclientTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.111.9.3.1.1 | Rowpm100gfmuxdCfgLabelclientEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.111.9.3.1.1.1 | Columnpm100gfmuxdCfgLabelclientIndex | read-only | current | Index definition for the labelclient table |
| 1.3.6.1.4.1.20044.111.9.3.1.1.3 | Columnpm100gfmuxdCfgLabelclientPortn | read-write | current | Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. |
| 1.3.6.1.4.1.20044.111.9.3.2 | Tablepm100gfmuxdCfgLabellineTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.111.9.3.2.1 | Rowpm100gfmuxdCfgLabellineEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.111.9.3.2.1.1 | Columnpm100gfmuxdCfgLabellineIndex | read-only | current | Index definition for the labelline table |
| 1.3.6.1.4.1.20044.111.9.3.2.1.3 | Columnpm100gfmuxdCfgLabellinePortn | read-write | current | Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. |
| 1.3.6.1.4.1.20044.111.9.4 | Nodepm100gfmuxdCfgStartuptlh | |||
| 1.3.6.1.4.1.20044.111.9.4.1 | Tablepm100gfmuxdCfgOtxtlhTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.111.9.4.1.1 | Rowpm100gfmuxdCfgOtxtlhEntry | not-accessible | current | Row definition for the startuptlh table |
| 1.3.6.1.4.1.20044.111.9.4.1.1.1 | Columnpm100gfmuxdCfgOtxtlhIndex | read-only | current | Index definition for the otxtlh table |
| 1.3.6.1.4.1.20044.111.9.4.1.1.6 | Columnpm100gfmuxdCfgLinePwrLaserPortn | read-write | deprecated | Defaut Line output Power :This register configures the start-up output power of the Line tranceiver (Unit = dBm) |
| 1.3.6.1.4.1.20044.111.9.4.1.1.7 | Columnpm100gfmuxdCfgLineFCurrentPortn | read-write | deprecated | Default Line transceiver Tx Channel :This register configures the start-up laser channel of the Line Tx transceiver |
| 1.3.6.1.4.1.20044.111.9.4.1.1.8 | Columnpm100gfmuxdCfgLineGridCurrentPortn | read-write | deprecated | Default Line transceiver Grid :This register configures the start-up laser grid of the Line transceiver |
| 1.3.6.1.4.1.20044.111.9.4.1.1.9 | Columnpm100gfmuxdCfgFPortn | read-write | deprecated | Default Line TRX lowest Freq :This register configures the start-up lowest frequency of the Line transceiver |
| 1.3.6.1.4.1.20044.111.9.4.1.1.10 | Columnpm100gfmuxdCfgRxLineFCurrentPortn | read-write | deprecated | Default Line transceiver Rx Channel :This register configures the start-up laser channel of the Line Rx transceiver |
| 1.3.6.1.4.1.20044.111.9.5 | Nodepm100gfmuxdCfgOther | |||
| 1.3.6.1.4.1.20044.111.9.5.1 | Nodepm100gfmuxdtablemoduleOther | |||
| 1.3.6.1.4.1.20044.111.9.5.1.5 | Scalarpm100gfmuxdCfgmoduleMode | read-write | current | Default settings on Module :This register selects the configuration mode of the module |
| 1.3.6.1.4.1.20044.111.9.10 | Nodepm100gfmuxdCfgStartuptablefive | |||
| 1.3.6.1.4.1.20044.111.9.10.1 | Tablepm100gfmuxdCfgOtxtlhcapabilitiesTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.111.9.10.1.1 | Rowpm100gfmuxdCfgOtxtlhcapabilitiesEntry | not-accessible | current | Row definition for the startuptablefive table |
| 1.3.6.1.4.1.20044.111.9.10.1.1.1 | Columnpm100gfmuxdCfgOtxtlhcapabilitiesIndex | read-only | current | Index definition for the otxtlhcapabilities table |
| 1.3.6.1.4.1.20044.111.9.10.1.1.3 | Columnpm100gfmuxdCfgComponentTypePortn | read-only | deprecated | Component parameters :This OID defines the component parameters |
| 1.3.6.1.4.1.20044.111.9.10.1.1.4 | Columnpm100gfmuxdCfgMiscellaneousPortn | read-only | deprecated | Miscellaneous default settings :This OID defines the miscellaneous parameters |
| 1.3.6.1.4.1.20044.111.9.10.1.1.5 | Columnpm100gfmuxdCfgFirstChannelPortn | read-only | deprecated | Number of the first channel of the component :This OID defines the first channel number of the PM |
| 1.3.6.1.4.1.20044.111.9.10.1.1.6 | Columnpm100gfmuxdCfgLastChannelPortn | read-only | deprecated | Number of the last channel of the component :This OID defines the last channel number of the PM |
| 1.3.6.1.4.1.20044.111.9.10.1.1.7 | Columnpm100gfmuxdCfgGridPortn | read-only | deprecated | Grid value of the component :This OID defines the grid of the PM |
| 1.3.6.1.4.1.20044.111.9.257 | Scalarpm100gfmuxdCfgWriteConfiguration | read-write | current | Write configuration to module:This OID writes the complete configuration to the module |
| 1.3.6.1.4.1.20044.111.10 | Nodepm100gfmuxdtraps | |||
| 1.3.6.1.4.1.20044.111.10.2 | Scalarpm100gfmuxdtrapPortNumber | read-only | current | Last port which generates a trap |
| 1.3.6.1.4.1.20044.111.10.3 | Scalarpm100gfmuxdtrapLineNumber | read-only | current | Last Line which generates a trap |
| 1.3.6.1.4.1.20044.111.10.4 | Scalarpm100gfmuxdtrapBoardNumber | read-only | current | Last module which generates a trap |
| 1.3.6.1.4.1.20044.111.10.30 | Notificationpm100gfmuxdLineTrapNotUrgentGoesOn | current | Not urgent Line default is activated | |
| 1.3.6.1.4.1.20044.111.10.31 | Notificationpm100gfmuxdLineTrapNotUrgentGoesOff | current | Not urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.111.10.32 | Notificationpm100gfmuxdLineTrapUrgentGoesOn | current | Urgent Line default is activated | |
| 1.3.6.1.4.1.20044.111.10.33 | Notificationpm100gfmuxdLineTrapUrgentGoesOff | current | Urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.111.10.34 | Notificationpm100gfmuxdLineTrapCritGoesOn | current | Critical Line default is activated | |
| 1.3.6.1.4.1.20044.111.10.35 | Notificationpm100gfmuxdLineTrapCritGoesOff | current | Critical Line default disappeared | |
| 1.3.6.1.4.1.20044.111.10.40 | Notificationpm100gfmuxdClientTrapNotUrgentGoesOn | current | Not urgent client default is activated | |
| 1.3.6.1.4.1.20044.111.10.41 | Notificationpm100gfmuxdClientTrapNotUrgentGoesOff | current | Not urgent client default disappeared | |
| 1.3.6.1.4.1.20044.111.10.42 | Notificationpm100gfmuxdClientTrapUrgentGoesOn | current | Urgent client default is activated | |
| 1.3.6.1.4.1.20044.111.10.43 | Notificationpm100gfmuxdClientTrapUrgentGoesOff | current | Urgent client default disappeared | |
| 1.3.6.1.4.1.20044.111.10.44 | Notificationpm100gfmuxdClientTrapCritGoesOn | current | Critical client default is activated | |
| 1.3.6.1.4.1.20044.111.10.45 | Notificationpm100gfmuxdClientTrapCritGoesOff | current | Critical client default disappeared | |
| 1.3.6.1.4.1.20044.111.10.50 | Notificationpm100gfmuxdPowerTrapUrgentGoesOn | current | Urgent power supply default is activated | |
| 1.3.6.1.4.1.20044.111.10.51 | Notificationpm100gfmuxdPowerTrapUrgentGoesOff | current | Urgent power supply default disappeared | |
| 1.3.6.1.4.1.20044.111.11 | Nodepm100gfmuxdMonitoring | |||
| 1.3.6.1.4.1.20044.111.11.1 | Nodepm100gfmuxdMonOther | |||
| 1.3.6.1.4.1.20044.111.11.1.3 | Nodepm100gfmuxdMonRmon | |||
| 1.3.6.1.4.1.20044.111.11.2 | Nodepm100gfmuxdMonClient | |||
| 1.3.6.1.4.1.20044.111.11.2.4 | Nodepm100gfmuxdMonClientRmonCounter | |||
| 1.3.6.1.4.1.20044.111.11.3 | Nodepm100gfmuxdMonLine | |||
| 1.3.6.1.4.1.20044.111.11.3.4 | Nodepm100gfmuxdMonLineRmonCounter | |||
| 1.3.6.1.4.1.20044.111.11.5 | Nodepm100gfmuxdMonPerfOther | |||
| 1.3.6.1.4.1.20044.111.11.5.1 | Nodepm100gfmuxdMonPerfSync | |||
| 1.3.6.1.4.1.20044.111.11.5.1.257 | Scalarpm100gfmuxdPerfEnable | read-write | current | Perf. Mon. Enable :This OID enables the Performance Monitoring application |
| 1.3.6.1.4.1.20044.111.11.5.1.259 | Scalarpm100gfmuxdPerf15minSync | read-write | current | Perf. Mon. 15-min sync. :This OID must be used in external synchronisation mode only to send a 15-min synchronisation command |
| 1.3.6.1.4.1.20044.111.11.5.1.260 | Scalarpm100gfmuxdPerf24hSync | read-write | current | Perf. Mon. 24-hours sync. :This OID must be used in external synchronisation mode only to send a 24-hours synchronisation command |
| 1.3.6.1.4.1.20044.111.11.5.2 | Nodepm100gfmuxdMonPerfTimeStamp | |||
| 1.3.6.1.4.1.20044.111.11.5.2.1 | Scalarpm100gfmuxdPerf15MinShort | read-write | current | 15-min period is short :This OID indicates that the 15-min period lasts less than 890 seconds |
| 1.3.6.1.4.1.20044.111.11.5.2.2 | Scalarpm100gfmuxdPerf15MinLong | read-write | current | 15-min period is long :This OID indicates that the 15-min period lasts more than 910 seconds |
| 1.3.6.1.4.1.20044.111.11.5.2.5 | Scalarpm100gfmuxdPerf24HoursShort | read-write | current | 24-hours period is short :This OID indicates that 24-hours period lasts less than 86390 seconds |
| 1.3.6.1.4.1.20044.111.11.5.2.6 | Scalarpm100gfmuxdPerf24HoursLong | read-write | current | 24-hours period is long :This OID indicates that 24-hours period lasts more than 86410 seconds |
| 1.3.6.1.4.1.20044.111.11.5.2.7 | Scalarpm100gfmuxdPerfCurrent15MinElapsedTime | read-write | current | Current 15min period Elapsed Time :This OID gives the number of seconds elapsed in the current 15-minutes period |
| 1.3.6.1.4.1.20044.111.11.5.2.8 | Scalarpm100gfmuxdPerfCurrent24HoursElapsedTime | read-write | current | Current 24hours period Elapsed Time :This OID gives the number of seconds elapsed in the current 24-hours period |
| 1.3.6.1.4.1.20044.111.11.6 | Nodepm100gfmuxdMonPerfClient | |||
| 1.3.6.1.4.1.20044.111.11.6.16 | Tablepm100gfmuxdPerfTelecomInputClientCurrent15StatTable | not-accessible | current | List of pm100gfmuxdPerfTelecomInputClientCurrent15Stat Article |
| 1.3.6.1.4.1.20044.111.11.6.16.1 | Rowpm100gfmuxdPerfTelecomInputClientCurrent15StatEntry | not-accessible | current | Row definition for the pm100gfmuxdPerfTelecomInputClientCurrent15Stat table |
| 1.3.6.1.4.1.20044.111.11.6.16.1.1 | Columnpm100gfmuxdPerfTelecomInputClientCurrent15StatIndex | read-only | current | Index definition for the pm100gfmuxdPerfTelecomInputClientCurrent15Stat table |
| 1.3.6.1.4.1.20044.111.11.6.16.1.2 | Columnpm100gfmuxdPerfTelecomInputClientCurrent15StatInvCvPortn | read-only | current | Current 15-min EBC counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.16.1.3 | Columnpm100gfmuxdPerfTelecomInputClientCurrent15StatCvValuePortn | read-only | current | Current 15-min EBC counter :This OID gives the current 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.111.11.6.16.1.4 | Columnpm100gfmuxdPerfTelecomInputClientCurrent15StatInvEsPortn | read-only | current | Current 15-min ES counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.16.1.5 | Columnpm100gfmuxdPerfTelecomInputClientCurrent15StatEsValuePortn | read-only | current | Current 15-min ES counter :This OID gives the current 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.16.1.6 | Columnpm100gfmuxdPerfTelecomInputClientCurrent15StatInvSesPortn | read-only | current | Current 15-min SES counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.16.1.7 | Columnpm100gfmuxdPerfTelecomInputClientCurrent15StatSesValuePortn | read-only | current | Current 15-min SES counter :This OID gives the current 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.16.1.8 | Columnpm100gfmuxdPerfTelecomInputClientCurrent15StatInvSefsPortn | read-only | current | Current 15-min SEFS counter inv. :This OID indicates that the current 15-min severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.16.1.9 | Columnpm100gfmuxdPerfTelecomInputClientCurrent15StatSefsValuePortn | read-only | current | Current 15-min SEFS counter :This OID gives the current 15-min severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.16.1.10 | Columnpm100gfmuxdPerfTelecomInputClientCurrent15StatInvUasPortn | read-only | current | Current 15-min UAS counter inv. :This OID indicates that the current 15-min UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.16.1.11 | Columnpm100gfmuxdPerfTelecomInputClientCurrent15StatUasValuePortn | read-only | current | Current 15-min UAS counter :This OID gives the current 15-min UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.48 | Tablepm100gfmuxdPerfTelecomInputClientPast15StatHistoryPort1Table | not-accessible | current | List of pm100gfmuxdPerfTelecomInputClientPast15StatHistory Article |
| 1.3.6.1.4.1.20044.111.11.6.48.1 | Rowpm100gfmuxdPerfTelecomInputClientPast15StatHistoryPort1Entry | not-accessible | current | Row definition for the pm100gfmuxdPerfTelecomInputClientPast15StatHistory table |
| 1.3.6.1.4.1.20044.111.11.6.48.1.1 | Columnpm100gfmuxdPerfTelecomInputClientPast15StatHistoryPort1Index | read-only | current | Index definition for the pm100gfmuxdPerfTelecomInputClientPast15StatHistory table |
| 1.3.6.1.4.1.20044.111.11.6.48.1.2 | Columnpm100gfmuxdPerfTelecomInputClientPast15StatHistoryInvCvPort1 | read-only | current | Previous 15-min EBC counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.48.1.3 | Columnpm100gfmuxdPerfTelecomInputClientPast15StatHistoryCvValuePort1 | read-only | current | Previous 15-min EBC counter :This OID gives the previous 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.111.11.6.48.1.4 | Columnpm100gfmuxdPerfTelecomInputClientPast15StatHistoryInvEsPort1 | read-only | current | Previous 15-min ES counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.48.1.5 | Columnpm100gfmuxdPerfTelecomInputClientPast15StatHistoryEsValuePort1 | read-only | current | Previous 15-min ES counter :This OID gives the previous 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.48.1.6 | Columnpm100gfmuxdPerfTelecomInputClientPast15StatHistoryInvSesPort1 | read-only | current | Previous 15-min SES counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.48.1.7 | Columnpm100gfmuxdPerfTelecomInputClientPast15StatHistorySesValuePort1 | read-only | current | Previous 15-min SES counter :This OID gives the previous 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.48.1.8 | Columnpm100gfmuxdPerfTelecomInputClientPast15StatHistoryInvSefsPort1 | read-only | current | Previous 15-min SEFS counter inv. :This OID indicates that the previous 15-min severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.48.1.9 | Columnpm100gfmuxdPerfTelecomInputClientPast15StatHistorySefsValuePort1 | read-only | current | Previous 15-min SEFS counter :This OID gives the previous 15-min severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.48.1.10 | Columnpm100gfmuxdPerfTelecomInputClientPast15StatHistoryInvUasPort1 | read-only | current | Previous 15-min UAS counter inv. :This OID indicates that the previous 15-min UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.48.1.11 | Columnpm100gfmuxdPerfTelecomInputClientPast15StatHistoryUasValuePort1 | read-only | current | Previous 15-min UAS counter :This OID gives the previous 15-min UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.80 | Tablepm100gfmuxdPerfTelecomInputClientCurrent24StatTable | not-accessible | current | List of pm100gfmuxdPerfTelecomInputClientCurrent24Stat Article |
| 1.3.6.1.4.1.20044.111.11.6.80.1 | Rowpm100gfmuxdPerfTelecomInputClientCurrent24StatEntry | not-accessible | current | Row definition for the pm100gfmuxdPerfTelecomInputClientCurrent24Stat table |
| 1.3.6.1.4.1.20044.111.11.6.80.1.1 | Columnpm100gfmuxdPerfTelecomInputClientCurrent24StatIndex | read-only | current | Index definition for the pm100gfmuxdPerfTelecomInputClientCurrent24Stat table |
| 1.3.6.1.4.1.20044.111.11.6.80.1.2 | Columnpm100gfmuxdPerfTelecomInputClientCurrent24StatInvCvPortn | read-only | current | Current 24-hours EBC counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.80.1.3 | Columnpm100gfmuxdPerfTelecomInputClientCurrent24StatCvValuePortn | read-only | current | Current 24-hours EBC counter :This OID gives the current 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.111.11.6.80.1.4 | Columnpm100gfmuxdPerfTelecomInputClientCurrent24StatInvEsPortn | read-only | current | Current 24-hours ES counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.80.1.5 | Columnpm100gfmuxdPerfTelecomInputClientCurrent24StatEsValuePortn | read-only | current | Current 24-hours ES counter :This OID gives the current 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.80.1.6 | Columnpm100gfmuxdPerfTelecomInputClientCurrent24StatInvSesPortn | read-only | current | Current 24-hours SES counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.80.1.7 | Columnpm100gfmuxdPerfTelecomInputClientCurrent24StatSesValuePortn | read-only | current | Current 24-hours SES counter :This OID gives the current 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.80.1.8 | Columnpm100gfmuxdPerfTelecomInputClientCurrent24StatInvSefsPortn | read-only | current | Current 24-hours SEFS counter inv. :This OID indicates that the current 24-hours severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.80.1.9 | Columnpm100gfmuxdPerfTelecomInputClientCurrent24StatSefsValuePortn | read-only | current | Current 24-hours SEFS counter :This OID gives the current 24-hours severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.80.1.10 | Columnpm100gfmuxdPerfTelecomInputClientCurrent24StatInvUasPortn | read-only | current | Current 24-hours UAS counter inv. :This OID indicates that the current 24-hours UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.80.1.11 | Columnpm100gfmuxdPerfTelecomInputClientCurrent24StatUasValuePortn | read-only | current | Current 24-hours UAS counter :This OID gives the current 24-hours UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.112 | Tablepm100gfmuxdPerfTelecomInputClientPast24StatHistoryPort1Table | not-accessible | current | List of pm100gfmuxdPerfTelecomInputClientPast24StatHistory Article |
| 1.3.6.1.4.1.20044.111.11.6.112.1 | Rowpm100gfmuxdPerfTelecomInputClientPast24StatHistoryPort1Entry | not-accessible | current | Row definition for the pm100gfmuxdPerfTelecomInputClientPast24StatHistory table |
| 1.3.6.1.4.1.20044.111.11.6.112.1.1 | Columnpm100gfmuxdPerfTelecomInputClientPast24StatHistoryPort1Index | read-only | current | Index definition for the pm100gfmuxdPerfTelecomInputClientPast24StatHistory table |
| 1.3.6.1.4.1.20044.111.11.6.112.1.2 | Columnpm100gfmuxdPerfTelecomInputClientPast24StatHistoryInvCvPort1 | read-only | current | Previous 24-hours EBC counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.112.1.3 | Columnpm100gfmuxdPerfTelecomInputClientPast24StatHistoryCvValuePort1 | read-only | current | Previous 24-hours EBC counter :This OID gives the previous 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.111.11.6.112.1.4 | Columnpm100gfmuxdPerfTelecomInputClientPast24StatHistoryInvEsPort1 | read-only | current | Previous 24-hours ES counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.112.1.5 | Columnpm100gfmuxdPerfTelecomInputClientPast24StatHistoryEsValuePort1 | read-only | current | Previous 24-hours ES counter :This OID gives the previous 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.112.1.6 | Columnpm100gfmuxdPerfTelecomInputClientPast24StatHistoryInvSesPort1 | read-only | current | Previous 24-hours SES counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.112.1.7 | Columnpm100gfmuxdPerfTelecomInputClientPast24StatHistorySesValuePort1 | read-only | current | Previous 24-hours SES counter :This OID gives the previous 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.112.1.8 | Columnpm100gfmuxdPerfTelecomInputClientPast24StatHistoryInvSefsPort1 | read-only | current | Previous 24-hours SEFS counter inv. :This OID indicates that the previous 24-hours severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.112.1.9 | Columnpm100gfmuxdPerfTelecomInputClientPast24StatHistorySefsValuePort1 | read-only | current | Previous 24-hours SEFS counter :This OID gives the previous 24-hours severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.112.1.10 | Columnpm100gfmuxdPerfTelecomInputClientPast24StatHistoryInvUasPort1 | read-only | current | Previous 24-hours UAS counter inv. :This OID indicates that the previous 24-hours UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.112.1.11 | Columnpm100gfmuxdPerfTelecomInputClientPast24StatHistoryUasValuePort1 | read-only | current | Previous 24-hours UAS counter :This OID gives the previous 24-hours UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.144 | Tablepm100gfmuxdPerfTelecomOutputClientCurrent15StatTable | not-accessible | current | List of pm100gfmuxdPerfTelecomOutputClientCurrent15Stat Article |
| 1.3.6.1.4.1.20044.111.11.6.144.1 | Rowpm100gfmuxdPerfTelecomOutputClientCurrent15StatEntry | not-accessible | current | Row definition for the pm100gfmuxdPerfTelecomOutputClientCurrent15Stat table |
| 1.3.6.1.4.1.20044.111.11.6.144.1.1 | Columnpm100gfmuxdPerfTelecomOutputClientCurrent15StatIndex | read-only | current | Index definition for the pm100gfmuxdPerfTelecomOutputClientCurrent15Stat table |
| 1.3.6.1.4.1.20044.111.11.6.144.1.2 | Columnpm100gfmuxdPerfTelecomOutputClientCurrent15StatInvCvPortn | read-only | current | Current 15-min EBC counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.144.1.3 | Columnpm100gfmuxdPerfTelecomOutputClientCurrent15StatCvValuePortn | read-only | current | Current 15-min EBC counter :This OID gives the current 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.111.11.6.144.1.4 | Columnpm100gfmuxdPerfTelecomOutputClientCurrent15StatInvEsPortn | read-only | current | Current 15-min ES counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.144.1.5 | Columnpm100gfmuxdPerfTelecomOutputClientCurrent15StatEsValuePortn | read-only | current | Current 15-min ES counter :This OID gives the current 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.144.1.6 | Columnpm100gfmuxdPerfTelecomOutputClientCurrent15StatInvSesPortn | read-only | current | Current 15-min SES counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.144.1.7 | Columnpm100gfmuxdPerfTelecomOutputClientCurrent15StatSesValuePortn | read-only | current | Current 15-min SES counter :This OID gives the current 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.144.1.8 | Columnpm100gfmuxdPerfTelecomOutputClientCurrent15StatInvSefsPortn | read-only | current | Current 15-min SEFS counter inv. :This OID indicates that the current 15-min severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.144.1.9 | Columnpm100gfmuxdPerfTelecomOutputClientCurrent15StatSefsValuePortn | read-only | current | Current 15-min SEFS counter :This OID gives the current 15-min severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.144.1.10 | Columnpm100gfmuxdPerfTelecomOutputClientCurrent15StatInvUasPortn | read-only | current | Current 15-min UAS counter inv. :This OID indicates that the current 15-min UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.144.1.11 | Columnpm100gfmuxdPerfTelecomOutputClientCurrent15StatUasValuePortn | read-only | current | Current 15-min UAS counter :This OID gives the current 15-min UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.176 | Tablepm100gfmuxdPerfTelecomOutputClientPast15StatHistoryPort1Table | not-accessible | current | List of pm100gfmuxdPerfTelecomOutputClientPast15StatHistory Article |
| 1.3.6.1.4.1.20044.111.11.6.176.1 | Rowpm100gfmuxdPerfTelecomOutputClientPast15StatHistoryPort1Entry | not-accessible | current | Row definition for the pm100gfmuxdPerfTelecomOutputClientPast15StatHistory table |
| 1.3.6.1.4.1.20044.111.11.6.176.1.1 | Columnpm100gfmuxdPerfTelecomOutputClientPast15StatHistoryPort1Index | read-only | current | Index definition for the pm100gfmuxdPerfTelecomOutputClientPast15StatHistory table |
| 1.3.6.1.4.1.20044.111.11.6.176.1.2 | Columnpm100gfmuxdPerfTelecomOutputClientPast15StatHistoryInvCvPort1 | read-only | current | Previous 15-min EBC counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.176.1.3 | Columnpm100gfmuxdPerfTelecomOutputClientPast15StatHistoryCvValuePort1 | read-only | current | Previous 15-min EBC counter :This OID gives the previous 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.111.11.6.176.1.4 | Columnpm100gfmuxdPerfTelecomOutputClientPast15StatHistoryInvEsPort1 | read-only | current | Previous 15-min ES counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.176.1.5 | Columnpm100gfmuxdPerfTelecomOutputClientPast15StatHistoryEsValuePort1 | read-only | current | Previous 15-min ES counter :This OID gives the previous 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.176.1.6 | Columnpm100gfmuxdPerfTelecomOutputClientPast15StatHistoryInvSesPort1 | read-only | current | Previous 15-min SES counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.176.1.7 | Columnpm100gfmuxdPerfTelecomOutputClientPast15StatHistorySesValuePort1 | read-only | current | Previous 15-min SES counter :This OID gives the previous 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.176.1.8 | Columnpm100gfmuxdPerfTelecomOutputClientPast15StatHistoryInvSefsPort1 | read-only | current | Previous 15-min SEFS counter inv. :This OID indicates that the previous 15-min severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.176.1.9 | Columnpm100gfmuxdPerfTelecomOutputClientPast15StatHistorySefsValuePort1 | read-only | current | Previous 15-min SEFS counter :This OID gives the previous 15-min severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.176.1.10 | Columnpm100gfmuxdPerfTelecomOutputClientPast15StatHistoryInvUasPort1 | read-only | current | Previous 15-min UAS counter inv. :This OID indicates that the previous 15-min UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.176.1.11 | Columnpm100gfmuxdPerfTelecomOutputClientPast15StatHistoryUasValuePort1 | read-only | current | Previous 15-min UAS counter :This OID gives the previous 15-min UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.208 | Tablepm100gfmuxdPerfTelecomOutputClientCurrent24StatTable | not-accessible | current | List of pm100gfmuxdPerfTelecomOutputClientCurrent24Stat Article |
| 1.3.6.1.4.1.20044.111.11.6.208.1 | Rowpm100gfmuxdPerfTelecomOutputClientCurrent24StatEntry | not-accessible | current | Row definition for the pm100gfmuxdPerfTelecomOutputClientCurrent24Stat table |
| 1.3.6.1.4.1.20044.111.11.6.208.1.1 | Columnpm100gfmuxdPerfTelecomOutputClientCurrent24StatIndex | read-only | current | Index definition for the pm100gfmuxdPerfTelecomOutputClientCurrent24Stat table |
| 1.3.6.1.4.1.20044.111.11.6.208.1.2 | Columnpm100gfmuxdPerfTelecomOutputClientCurrent24StatInvCvPortn | read-only | current | Current 24-hours EBC counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.208.1.3 | Columnpm100gfmuxdPerfTelecomOutputClientCurrent24StatCvValuePortn | read-only | current | Current 24-hours EBC counter :This OID gives the current 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.111.11.6.208.1.4 | Columnpm100gfmuxdPerfTelecomOutputClientCurrent24StatInvEsPortn | read-only | current | Current 24-hours ES counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.208.1.5 | Columnpm100gfmuxdPerfTelecomOutputClientCurrent24StatEsValuePortn | read-only | current | Current 24-hours ES counter :This OID gives the current 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.208.1.6 | Columnpm100gfmuxdPerfTelecomOutputClientCurrent24StatInvSesPortn | read-only | current | Current 24-hours SES counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.208.1.7 | Columnpm100gfmuxdPerfTelecomOutputClientCurrent24StatSesValuePortn | read-only | current | Current 24-hours SES counter :This OID gives the current 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.208.1.8 | Columnpm100gfmuxdPerfTelecomOutputClientCurrent24StatInvSefsPortn | read-only | current | Current 24-hours SEFS counter inv. :This OID indicates that the current 24-hours severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.208.1.9 | Columnpm100gfmuxdPerfTelecomOutputClientCurrent24StatSefsValuePortn | read-only | current | Current 24-hours SEFS counter :This OID gives the current 24-hours severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.208.1.10 | Columnpm100gfmuxdPerfTelecomOutputClientCurrent24StatInvUasPortn | read-only | current | Current 24-hours UAS counter inv. :This OID indicates that the current 24-hours UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.208.1.11 | Columnpm100gfmuxdPerfTelecomOutputClientCurrent24StatUasValuePortn | read-only | current | Current 24-hours UAS counter :This OID gives the current 24-hours UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.240 | Tablepm100gfmuxdPerfTelecomOutputClientPast24StatHistoryPort1Table | not-accessible | current | List of pm100gfmuxdPerfTelecomOutputClientPast24StatHistory Article |
| 1.3.6.1.4.1.20044.111.11.6.240.1 | Rowpm100gfmuxdPerfTelecomOutputClientPast24StatHistoryPort1Entry | not-accessible | current | Row definition for the pm100gfmuxdPerfTelecomOutputClientPast24StatHistory table |
| 1.3.6.1.4.1.20044.111.11.6.240.1.1 | Columnpm100gfmuxdPerfTelecomOutputClientPast24StatHistoryPort1Index | read-only | current | Index definition for the pm100gfmuxdPerfTelecomOutputClientPast24StatHistory table |
| 1.3.6.1.4.1.20044.111.11.6.240.1.2 | Columnpm100gfmuxdPerfTelecomOutputClientPast24StatHistoryInvCvPort1 | read-only | current | Previous 24-hours EBC counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.240.1.3 | Columnpm100gfmuxdPerfTelecomOutputClientPast24StatHistoryCvValuePort1 | read-only | current | Previous 24-hours EBC counter :This OID gives the previous 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.111.11.6.240.1.4 | Columnpm100gfmuxdPerfTelecomOutputClientPast24StatHistoryInvEsPort1 | read-only | current | Previous 24-hours ES counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.240.1.5 | Columnpm100gfmuxdPerfTelecomOutputClientPast24StatHistoryEsValuePort1 | read-only | current | Previous 24-hours ES counter :This OID gives the previous 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.240.1.6 | Columnpm100gfmuxdPerfTelecomOutputClientPast24StatHistoryInvSesPort1 | read-only | current | Previous 24-hours SES counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.240.1.7 | Columnpm100gfmuxdPerfTelecomOutputClientPast24StatHistorySesValuePort1 | read-only | current | Previous 24-hours SES counter :This OID gives the previous 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.240.1.8 | Columnpm100gfmuxdPerfTelecomOutputClientPast24StatHistoryInvSefsPort1 | read-only | current | Previous 24-hours SEFS counter inv. :This OID indicates that the previous 24-hours severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.240.1.9 | Columnpm100gfmuxdPerfTelecomOutputClientPast24StatHistorySefsValuePort1 | read-only | current | Previous 24-hours SEFS counter :This OID gives the previous 24-hours severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.240.1.10 | Columnpm100gfmuxdPerfTelecomOutputClientPast24StatHistoryInvUasPort1 | read-only | current | Previous 24-hours UAS counter inv. :This OID indicates that the previous 24-hours UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.240.1.11 | Columnpm100gfmuxdPerfTelecomOutputClientPast24StatHistoryUasValuePort1 | read-only | current | Previous 24-hours UAS counter :This OID gives the previous 24-hours UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.111.11.6.848 | Tablepm100gfmuxdPerfDatacomClientCurrent15StatTable | not-accessible | current | List of pm100gfmuxdPerfDatacomClientCurrent15Stat Article |
| 1.3.6.1.4.1.20044.111.11.6.848.1 | Rowpm100gfmuxdPerfDatacomClientCurrent15StatEntry | not-accessible | current | Row definition for the pm100gfmuxdPerfDatacomClientCurrent15Stat table |
| 1.3.6.1.4.1.20044.111.11.6.848.1.1 | Columnpm100gfmuxdPerfDatacomClientCurrent15StatIndex | read-only | current | Index definition for the pm100gfmuxdPerfDatacomClientCurrent15Stat table |
| 1.3.6.1.4.1.20044.111.11.6.848.1.4 | Columnpm100gfmuxdperfdatacomclientCurrent15StatInCrcCountInvPortn | read-only | current | Client Current 15-min Input CRC counter inv. :This OID indicates that the current 15-min Input CRC counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.848.1.5 | Columnpm100gfmuxdperfdatacomclientCurrent15StatInCrcCountPortn | read-only | current | Client Current 15-min Input CRC counter :This OID gives the current 15-min Input CRC counter value |
| 1.3.6.1.4.1.20044.111.11.6.848.1.6 | Columnpm100gfmuxdperfdatacomclientCurrent15StatInPacketCountInvPortn | read-only | current | Client Current 15-min Input Packet counter inv. :This OID indicates that the current 15-min Input Packet counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.848.1.7 | Columnpm100gfmuxdperfdatacomclientCurrent15StatInPacketCountPortn | read-only | current | Client Current 15-min Input Packet counter :This OID gives the current 15-min Input Packet counter value |
| 1.3.6.1.4.1.20044.111.11.6.848.1.28 | Columnpm100gfmuxdperfdatacomclientCurrent15StatOutCrcCountInvPortn | read-only | current | Client Current 15-min Output CRC counter inv. :This OID indicates that the current 15-min Output CRC counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.848.1.29 | Columnpm100gfmuxdperfdatacomclientCurrent15StatOutCrcCountPortn | read-only | current | Client Current 15-min Output CRC counter :This OID gives the current 15-min Output CRC counter value |
| 1.3.6.1.4.1.20044.111.11.6.848.1.30 | Columnpm100gfmuxdperfdatacomclientCurrent15StatOutPacketCountInvPortn | read-only | current | Client Current 15-min Output Packet counter inv. :This OID indicates that the current 15-min Output Packets counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.848.1.31 | Columnpm100gfmuxdperfdatacomclientCurrent15StatOutPacketCountPortn | read-only | current | Client Current 15-min Output Packet counter :This OID gives the current 15-min Output Packets counter value |
| 1.3.6.1.4.1.20044.111.11.6.880 | Tablepm100gfmuxdPerfDatacomClientPast15StatHistoryPort1Table | not-accessible | current | List of pm100gfmuxdPerfDatacomClientPast15StatHistory Article |
| 1.3.6.1.4.1.20044.111.11.6.880.1 | Rowpm100gfmuxdPerfDatacomClientPast15StatHistoryPort1Entry | not-accessible | current | Row definition for the pm100gfmuxdPerfDatacomClientPast15StatHistory table |
| 1.3.6.1.4.1.20044.111.11.6.880.1.1 | Columnpm100gfmuxdPerfDatacomClientPast15StatHistoryPort1Index | read-only | current | Index definition for the pm100gfmuxdPerfDatacomClientPast15StatHistory table |
| 1.3.6.1.4.1.20044.111.11.6.880.1.4 | Columnpm100gfmuxdperfdatacomclientPast15StatInCrcCountInvPort1 | read-only | current | Client Past 15-min Input CRC counter inv. :This OID indicates that the past 15-min Input CRC counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.880.1.5 | Columnpm100gfmuxdperfdatacomclientPast15StatInCrcCountPort1 | read-only | current | Client Past 15-min Input CRC counter :This OID gives the past 15-min Input CRC counter value |
| 1.3.6.1.4.1.20044.111.11.6.880.1.6 | Columnpm100gfmuxdperfdatacomclientPast15StatInPacketCountInvPort1 | read-only | current | Client Past 15-min Input Packet counter inv. :This OID indicates that the past 15-min Input Packet counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.880.1.7 | Columnpm100gfmuxdperfdatacomclientPast15StatInPacketCountPort1 | read-only | current | Client Past 15-min Input Packet counter :This OID gives the past 15-min Input Packet counter value |
| 1.3.6.1.4.1.20044.111.11.6.880.1.28 | Columnpm100gfmuxdperfdatacomclientPast15StatOutCrcCountInvPort1 | read-only | current | Client Past 15-min Output CRC counter inv. :This OID indicates that the past 15-min Output CRC counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.880.1.29 | Columnpm100gfmuxdperfdatacomclientPast15StatOutCrcCountPort1 | read-only | current | Client Past 15-min Output CRC counter :This OID gives the past 15-min Output CRC counter value |
| 1.3.6.1.4.1.20044.111.11.6.880.1.30 | Columnpm100gfmuxdperfdatacomclientPast15StatOutPacketCountInvPort1 | read-only | current | Client Past 15-min Output Packet counter inv. :This OID indicates that the past 15-min Output Packets counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.880.1.31 | Columnpm100gfmuxdperfdatacomclientPast15StatOutPacketCountPort1 | read-only | current | Client Past 15-min Output Packet counter :This OID gives the past 15-min Output Packets counter value |
| 1.3.6.1.4.1.20044.111.11.6.912 | Tablepm100gfmuxdPerfDatacomClientCurrent24StatTable | not-accessible | current | List of pm100gfmuxdPerfDatacomClientCurrent24Stat Article |
| 1.3.6.1.4.1.20044.111.11.6.912.1 | Rowpm100gfmuxdPerfDatacomClientCurrent24StatEntry | not-accessible | current | Row definition for the pm100gfmuxdPerfDatacomClientCurrent24Stat table |
| 1.3.6.1.4.1.20044.111.11.6.912.1.1 | Columnpm100gfmuxdPerfDatacomClientCurrent24StatIndex | read-only | current | Index definition for the pm100gfmuxdPerfDatacomClientCurrent24Stat table |
| 1.3.6.1.4.1.20044.111.11.6.912.1.4 | Columnpm100gfmuxdperfdatacomclientCurrent24StatInCrcCountInvPortn | read-only | current | Client Current 24-hours Input CRC counter inv. :This OID indicates that the current 24-hours Input CRC counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.912.1.5 | Columnpm100gfmuxdperfdatacomclientCurrent24StatInCrcCountPortn | read-only | current | Client Current 24-hours Input CRC counter :This OID gives the current 24-hours Input CRC counter value |
| 1.3.6.1.4.1.20044.111.11.6.912.1.6 | Columnpm100gfmuxdperfdatacomclientCurrent24StatInPacketCountInvPortn | read-only | current | Client Current 24-hours Input Packet counter inv. :This OID indicates that the current 24-hours Input Packet counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.912.1.7 | Columnpm100gfmuxdperfdatacomclientCurrent24StatInPacketCountPortn | read-only | current | Client Current 24-hours Input Packet counter :This OID gives the current 24-hours Input Packet counter value |
| 1.3.6.1.4.1.20044.111.11.6.912.1.28 | Columnpm100gfmuxdperfdatacomclientCurrent24StatOutCrcCountInvPortn | read-only | current | Client Current 24-hours Output CRC counter inv. :This OID indicates that the current 24-hours Output CRC counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.912.1.29 | Columnpm100gfmuxdperfdatacomclientCurrent24StatOutCrcCountPortn | read-only | current | Client Current 24-hours Output CRC counter :This OID gives the current 24-hours Output CRC counter value |
| 1.3.6.1.4.1.20044.111.11.6.912.1.30 | Columnpm100gfmuxdperfdatacomclientCurrent24StatOutPacketCountInvPortn | read-only | current | Client Current 24-hours Output Packet counter inv. :This OID indicates that the current 24-hours Output Packets counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.912.1.31 | Columnpm100gfmuxdperfdatacomclientCurrent24StatOutPacketCountPortn | read-only | current | Client Current 24-hours Output Packet counter :This OID gives the current 24-hours Output Packets counter value |
| 1.3.6.1.4.1.20044.111.11.6.944 | Tablepm100gfmuxdPerfDatacomClientPast24StatHistoryPort1Table | not-accessible | current | List of pm100gfmuxdPerfDatacomClientPast24StatHistory Article |
| 1.3.6.1.4.1.20044.111.11.6.944.1 | Rowpm100gfmuxdPerfDatacomClientPast24StatHistoryPort1Entry | not-accessible | current | Row definition for the pm100gfmuxdPerfDatacomClientPast24StatHistory table |
| 1.3.6.1.4.1.20044.111.11.6.944.1.1 | Columnpm100gfmuxdPerfDatacomClientPast24StatHistoryPort1Index | read-only | current | Index definition for the pm100gfmuxdPerfDatacomClientPast24StatHistory table |
| 1.3.6.1.4.1.20044.111.11.6.944.1.4 | Columnpm100gfmuxdperfdatacomclientPast24StatInCrcCountInvPort1 | read-only | current | Client Past 24-hours Input CRC counter inv. :This OID indicates that the past 24-hours Input CRC counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.944.1.5 | Columnpm100gfmuxdperfdatacomclientPast24StatInCrcCountPort1 | read-only | current | Client Past 24-hours Input CRC counter :This OID gives the past 24-hours Input CRC counter value |
| 1.3.6.1.4.1.20044.111.11.6.944.1.6 | Columnpm100gfmuxdperfdatacomclientPast24StatInPacketCountInvPort1 | read-only | current | Client Past 24-hours Input Packet counter inv. :This OID indicates that the past 24-hours Input Packet counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.944.1.7 | Columnpm100gfmuxdperfdatacomclientPast24StatInPacketCountPort1 | read-only | current | Client Past 24-hours Input Packet counter :This OID gives the past 24-hours Input Packet counter value |
| 1.3.6.1.4.1.20044.111.11.6.944.1.28 | Columnpm100gfmuxdperfdatacomclientPast24StatOutCrcCountInvPort1 | read-only | current | Client Past 24-hours Output CRC counter inv. :This OID indicates that the past 24-hours Output CRC counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.944.1.29 | Columnpm100gfmuxdperfdatacomclientPast24StatOutCrcCountPort1 | read-only | current | Client Past 24-hours Output CRC counter :This OID gives the past 24-hours Output CRC counter value |
| 1.3.6.1.4.1.20044.111.11.6.944.1.30 | Columnpm100gfmuxdperfdatacomclientPast24StatOutPacketCountInvPort1 | read-only | current | Client Past 24-hours Output Packet counter inv. :This OID indicates that the past 24-hours Output Packets counter is invalid |
| 1.3.6.1.4.1.20044.111.11.6.944.1.31 | Columnpm100gfmuxdperfdatacomclientPast24StatOutPacketCountPort1 | read-only | current | Client Past 24-hours Output Packet counter :This OID gives the past 24-hours Output Packets counter value |
| 1.3.6.1.4.1.20044.111.11.7 | Nodepm100gfmuxdMonPerfLine | |||
| 1.3.6.1.4.1.20044.111.11.7.336 | Tablepm100gfmuxdPerfTelecomLinePostFecCurrent15StatTable | not-accessible | current | List of pm100gfmuxdPerfTelecomLinePostFecCurrent15Stat Article |
| 1.3.6.1.4.1.20044.111.11.7.336.1 | Rowpm100gfmuxdPerfTelecomLinePostFecCurrent15StatEntry | not-accessible | current | Row definition for the pm100gfmuxdPerfTelecomLinePostFecCurrent15Stat table |
| 1.3.6.1.4.1.20044.111.11.7.336.1.1 | Columnpm100gfmuxdPerfTelecomLinePostFecCurrent15StatIndex | read-only | current | Index definition for the pm100gfmuxdPerfTelecomLinePostFecCurrent15Stat table |
| 1.3.6.1.4.1.20044.111.11.7.336.1.2 | Columnpm100gfmuxdPerfTelecomLinePostFecCurrent15StatInvCvPortn | read-only | current | Current 15-min EBC counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.336.1.3 | Columnpm100gfmuxdPerfTelecomLinePostFecCurrent15StatCvValuePortn | read-only | current | Current 15-min EBC counter :This OID gives the current 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.111.11.7.336.1.4 | Columnpm100gfmuxdPerfTelecomLinePostFecCurrent15StatInvEsPortn | read-only | current | Current 15-min ES counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.336.1.5 | Columnpm100gfmuxdPerfTelecomLinePostFecCurrent15StatEsValuePortn | read-only | current | Current 15-min ES counter :This OID gives the current 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.111.11.7.336.1.6 | Columnpm100gfmuxdPerfTelecomLinePostFecCurrent15StatInvSesPortn | read-only | current | Current 15-min SES counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.336.1.7 | Columnpm100gfmuxdPerfTelecomLinePostFecCurrent15StatSesValuePortn | read-only | current | Current 15-min SES counter :This OID gives the current 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.111.11.7.336.1.8 | Columnpm100gfmuxdPerfTelecomLinePostFecCurrent15StatInvSefsPortn | read-only | current | Current 15-min SEFS counter inv. :This OID indicates that the current 15-min severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.336.1.9 | Columnpm100gfmuxdPerfTelecomLinePostFecCurrent15StatSefsValuePortn | read-only | current | Current 15-min SEFS counter :This OID gives the current 15-min severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.111.11.7.336.1.10 | Columnpm100gfmuxdPerfTelecomLinePostFecCurrent15StatInvUasPortn | read-only | current | Current 15-min UAS counter inv. :This OID indicates that the current 15-min UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.336.1.11 | Columnpm100gfmuxdPerfTelecomLinePostFecCurrent15StatUasValuePortn | read-only | current | Current 15-min UAS counter :This OID gives the current 15-min UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.111.11.7.337 | Tablepm100gfmuxdPerfTelecomLinePostFecPast15StatHistoryPort1Table | not-accessible | current | List of pm100gfmuxdPerfTelecomLinePostFecPast15StatHistory Article |
| 1.3.6.1.4.1.20044.111.11.7.337.1 | Rowpm100gfmuxdPerfTelecomLinePostFecPast15StatHistoryPort1Entry | not-accessible | current | Row definition for the pm100gfmuxdPerfTelecomLinePostFecPast15StatHistory table |
| 1.3.6.1.4.1.20044.111.11.7.337.1.1 | Columnpm100gfmuxdPerfTelecomLinePostFecPast15StatHistoryPort1Index | read-only | current | Index definition for the pm100gfmuxdPerfTelecomLinePostFecPast15StatHistory table |
| 1.3.6.1.4.1.20044.111.11.7.337.1.2 | Columnpm100gfmuxdPerfTelecomLinePostFecPast15StatHistoryInvCvPort1 | read-only | current | Previous 15-min EBC counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.337.1.3 | Columnpm100gfmuxdPerfTelecomLinePostFecPast15StatHistoryCvValuePort1 | read-only | current | Previous 15-min EBC counter :This OID gives the previous 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.111.11.7.337.1.4 | Columnpm100gfmuxdPerfTelecomLinePostFecPast15StatHistoryInvEsPort1 | read-only | current | Previous 15-min ES counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.337.1.5 | Columnpm100gfmuxdPerfTelecomLinePostFecPast15StatHistoryEsValuePort1 | read-only | current | Previous 15-min ES counter :This OID gives the previous 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.111.11.7.337.1.6 | Columnpm100gfmuxdPerfTelecomLinePostFecPast15StatHistoryInvSesPort1 | read-only | current | Previous 15-min SES counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.337.1.7 | Columnpm100gfmuxdPerfTelecomLinePostFecPast15StatHistorySesValuePort1 | read-only | current | Previous 15-min SES counter :This OID gives the previous 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.111.11.7.337.1.8 | Columnpm100gfmuxdPerfTelecomLinePostFecPast15StatHistoryInvSefsPort1 | read-only | current | Previous 15-min SEFS counter inv. :This OID indicates that the previous 15-min severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.337.1.9 | Columnpm100gfmuxdPerfTelecomLinePostFecPast15StatHistorySefsValuePort1 | read-only | current | Previous 15-min SEFS counter :This OID gives the previous 15-min severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.111.11.7.337.1.10 | Columnpm100gfmuxdPerfTelecomLinePostFecPast15StatHistoryInvUasPort1 | read-only | current | Previous 15-min UAS counter inv. :This OID indicates that the previous 15-min UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.337.1.11 | Columnpm100gfmuxdPerfTelecomLinePostFecPast15StatHistoryUasValuePort1 | read-only | current | Previous 15-min UAS counter :This OID gives the previous 15-min UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.111.11.7.338 | Tablepm100gfmuxdPerfTelecomLinePostFecCurrent24StatTable | not-accessible | current | List of pm100gfmuxdPerfTelecomLinePostFecCurrent24Stat Article |
| 1.3.6.1.4.1.20044.111.11.7.338.1 | Rowpm100gfmuxdPerfTelecomLinePostFecCurrent24StatEntry | not-accessible | current | Row definition for the pm100gfmuxdPerfTelecomLinePostFecCurrent24Stat table |
| 1.3.6.1.4.1.20044.111.11.7.338.1.1 | Columnpm100gfmuxdPerfTelecomLinePostFecCurrent24StatIndex | read-only | current | Index definition for the pm100gfmuxdPerfTelecomLinePostFecCurrent24Stat table |
| 1.3.6.1.4.1.20044.111.11.7.338.1.2 | Columnpm100gfmuxdPerfTelecomLinePostFecCurrent24StatInvCvPortn | read-only | current | Current 24-hours EBC counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.338.1.3 | Columnpm100gfmuxdPerfTelecomLinePostFecCurrent24StatCvValuePortn | read-only | current | Current 24-hours EBC counter :This OID gives the current 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.111.11.7.338.1.4 | Columnpm100gfmuxdPerfTelecomLinePostFecCurrent24StatInvEsPortn | read-only | current | Current 24-hours ES counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.338.1.5 | Columnpm100gfmuxdPerfTelecomLinePostFecCurrent24StatEsValuePortn | read-only | current | Current 24-hours ES counter :This OID gives the current 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.111.11.7.338.1.6 | Columnpm100gfmuxdPerfTelecomLinePostFecCurrent24StatInvSesPortn | read-only | current | Current 24-hours SES counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.338.1.7 | Columnpm100gfmuxdPerfTelecomLinePostFecCurrent24StatSesValuePortn | read-only | current | Current 24-hours SES counter :This OID gives the current 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.111.11.7.338.1.8 | Columnpm100gfmuxdPerfTelecomLinePostFecCurrent24StatInvSefsPortn | read-only | current | Current 24-hours SEFS counter inv. :This OID indicates that the current 24-hours severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.338.1.9 | Columnpm100gfmuxdPerfTelecomLinePostFecCurrent24StatSefsValuePortn | read-only | current | Current 24-hours SEFS counter :This OID gives the current 24-hours severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.111.11.7.338.1.10 | Columnpm100gfmuxdPerfTelecomLinePostFecCurrent24StatInvUasPortn | read-only | current | Current 24-hours UAS counter inv. :This OID indicates that the current 24-hours UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.338.1.11 | Columnpm100gfmuxdPerfTelecomLinePostFecCurrent24StatUasValuePortn | read-only | current | Current 24-hours UAS counter :This OID gives the current 24-hours UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.111.11.7.339 | Tablepm100gfmuxdPerfTelecomLinePostFecPast24StatHistoryPort1Table | not-accessible | current | List of pm100gfmuxdPerfTelecomLinePostFecPast24StatHistory Article |
| 1.3.6.1.4.1.20044.111.11.7.339.1 | Rowpm100gfmuxdPerfTelecomLinePostFecPast24StatHistoryPort1Entry | not-accessible | current | Row definition for the pm100gfmuxdPerfTelecomLinePostFecPast24StatHistory table |
| 1.3.6.1.4.1.20044.111.11.7.339.1.1 | Columnpm100gfmuxdPerfTelecomLinePostFecPast24StatHistoryPort1Index | read-only | current | Index definition for the pm100gfmuxdPerfTelecomLinePostFecPast24StatHistory table |
| 1.3.6.1.4.1.20044.111.11.7.339.1.2 | Columnpm100gfmuxdPerfTelecomLinePostFecPast24StatHistoryInvCvPort1 | read-only | current | Previous 24-hours EBC counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.339.1.3 | Columnpm100gfmuxdPerfTelecomLinePostFecPast24StatHistoryCvValuePort1 | read-only | current | Previous 24-hours EBC counter :This OID gives the previous 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.111.11.7.339.1.4 | Columnpm100gfmuxdPerfTelecomLinePostFecPast24StatHistoryInvEsPort1 | read-only | current | Previous 24-hours ES counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.339.1.5 | Columnpm100gfmuxdPerfTelecomLinePostFecPast24StatHistoryEsValuePort1 | read-only | current | Previous 24-hours ES counter :This OID gives the previous 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.111.11.7.339.1.6 | Columnpm100gfmuxdPerfTelecomLinePostFecPast24StatHistoryInvSesPort1 | read-only | current | Previous 24-hours SES counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.339.1.7 | Columnpm100gfmuxdPerfTelecomLinePostFecPast24StatHistorySesValuePort1 | read-only | current | Previous 24-hours SES counter :This OID gives the previous 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.111.11.7.339.1.8 | Columnpm100gfmuxdPerfTelecomLinePostFecPast24StatHistoryInvSefsPort1 | read-only | current | Previous 24-hours SEFS counter inv. :This OID indicates that the previous 24-hours severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.339.1.9 | Columnpm100gfmuxdPerfTelecomLinePostFecPast24StatHistorySefsValuePort1 | read-only | current | Previous 24-hours SEFS counter :This OID gives the previous 24-hours severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.111.11.7.339.1.10 | Columnpm100gfmuxdPerfTelecomLinePostFecPast24StatHistoryInvUasPort1 | read-only | current | Previous 24-hours UAS counter inv. :This OID indicates that the previous 24-hours UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.339.1.11 | Columnpm100gfmuxdPerfTelecomLinePostFecPast24StatHistoryUasValuePort1 | read-only | current | Previous 24-hours UAS counter :This OID gives the previous 24-hours UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.111.11.7.352 | Tablepm100gfmuxdPerfTelecomBerLinePreFecCurrent15StatTable | not-accessible | current | List of pm100gfmuxdPerfTelecomBerLinePreFecCurrent15Stat Article |
| 1.3.6.1.4.1.20044.111.11.7.352.1 | Rowpm100gfmuxdPerfTelecomBerLinePreFecCurrent15StatEntry | not-accessible | current | Row definition for the pm100gfmuxdPerfTelecomBerLinePreFecCurrent15Stat table |
| 1.3.6.1.4.1.20044.111.11.7.352.1.1 | Columnpm100gfmuxdPerfTelecomBerLinePreFecCurrent15StatIndex | read-only | current | Index definition for the pm100gfmuxdPerfTelecomBerLinePreFecCurrent15Stat table |
| 1.3.6.1.4.1.20044.111.11.7.352.1.2 | Columnpm100gfmuxdPerfTelecomBerLinePreFecCurrent15StatInvBerPortn | read-only | current | Current 15-min BER counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.352.1.3 | Columnpm100gfmuxdPerfTelecomBerLinePreFecCurrent15StatBerValuePortn | read-only | current | Current 15-min BER counter :This OID gives the current 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.111.11.7.352.1.4 | Columnpm100gfmuxdPerfTelecomBerLinePreFecCurrent15StatInvMinBerPortn | read-only | current | Current 15-min MinBER counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.352.1.5 | Columnpm100gfmuxdPerfTelecomBerLinePreFecCurrent15StatMinBerValuePortn | read-only | current | Current 15-min MinBER counter :This OID gives the current 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.111.11.7.352.1.6 | Columnpm100gfmuxdPerfTelecomBerLinePreFecCurrent15StatInvMaxBerPortn | read-only | current | Current 15-min MaxBER counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.352.1.7 | Columnpm100gfmuxdPerfTelecomBerLinePreFecCurrent15StatMaxBerValuePortn | read-only | current | Current 15-min MaxBER counter :This OID gives the current 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.111.11.7.353 | Tablepm100gfmuxdPerfTelecomBerLinePreFecPast15StatHistoryPort1Table | not-accessible | current | List of pm100gfmuxdPerfTelecomBerLinePreFecPast15StatHistory Article |
| 1.3.6.1.4.1.20044.111.11.7.353.1 | Rowpm100gfmuxdPerfTelecomBerLinePreFecPast15StatHistoryPort1Entry | not-accessible | current | Row definition for the pm100gfmuxdPerfTelecomBerLinePreFecPast15StatHistory table |
| 1.3.6.1.4.1.20044.111.11.7.353.1.1 | Columnpm100gfmuxdPerfTelecomBerLinePreFecPast15StatHistoryPort1Index | read-only | current | Index definition for the pm100gfmuxdPerfTelecomBerLinePreFecPast15StatHistory table |
| 1.3.6.1.4.1.20044.111.11.7.353.1.2 | Columnpm100gfmuxdPerfTelecomBerLinePreFecPast15StatHistoryInvBerPort1 | read-only | current | Previous 15-min BER counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.353.1.3 | Columnpm100gfmuxdPerfTelecomBerLinePreFecPast15StatHistoryBerValuePort1 | read-only | current | Previous 15-min BER counter :This OID gives the previous 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.111.11.7.353.1.4 | Columnpm100gfmuxdPerfTelecomBerLinePreFecPast15StatHistoryInvMinBerPort1 | read-only | current | Previous 15-min MinBER counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.353.1.5 | Columnpm100gfmuxdPerfTelecomBerLinePreFecPast15StatHistoryMinBerValuePort1 | read-only | current | Previous 15-min MinBER counter :This OID gives the previous 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.111.11.7.353.1.6 | Columnpm100gfmuxdPerfTelecomBerLinePreFecPast15StatHistoryInvMaxBerPort1 | read-only | current | Previous 15-min MaxBER counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.353.1.7 | Columnpm100gfmuxdPerfTelecomBerLinePreFecPast15StatHistoryMaxBerValuePort1 | read-only | current | Previous 15-min MaxBER counter :This OID gives the previous 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.111.11.7.354 | Tablepm100gfmuxdPerfTelecomBerLinePreFecCurrent24StatTable | not-accessible | current | List of pm100gfmuxdPerfTelecomBerLinePreFecCurrent24Stat Article |
| 1.3.6.1.4.1.20044.111.11.7.354.1 | Rowpm100gfmuxdPerfTelecomBerLinePreFecCurrent24StatEntry | not-accessible | current | Row definition for the pm100gfmuxdPerfTelecomBerLinePreFecCurrent24Stat table |
| 1.3.6.1.4.1.20044.111.11.7.354.1.1 | Columnpm100gfmuxdPerfTelecomBerLinePreFecCurrent24StatIndex | read-only | current | Index definition for the pm100gfmuxdPerfTelecomBerLinePreFecCurrent24Stat table |
| 1.3.6.1.4.1.20044.111.11.7.354.1.2 | Columnpm100gfmuxdPerfTelecomBerLinePreFecCurrent24StatInvBerPortn | read-only | current | Current 24-hours BER counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.354.1.3 | Columnpm100gfmuxdPerfTelecomBerLinePreFecCurrent24StatBerValuePortn | read-only | current | Current 24-hours BER counter :This OID gives the current 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.111.11.7.354.1.4 | Columnpm100gfmuxdPerfTelecomBerLinePreFecCurrent24StatInvMinBerPortn | read-only | current | Current 24-hoursMinBER counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.354.1.5 | Columnpm100gfmuxdPerfTelecomBerLinePreFecCurrent24StatMinBerValuePortn | read-only | current | Current 24-hours MinBER counter :This OID gives the current 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.111.11.7.354.1.6 | Columnpm100gfmuxdPerfTelecomBerLinePreFecCurrent24StatInvMaxBerPortn | read-only | current | Current 24-hours MaxBER counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.354.1.7 | Columnpm100gfmuxdPerfTelecomBerLinePreFecCurrent24StatMaxBerValuePortn | read-only | current | Current 24-hours MaxBER counter :This OID gives the current 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.111.11.7.355 | Tablepm100gfmuxdPerfTelecomBerLinePreFecPast24StatHistoryPort1Table | not-accessible | current | List of pm100gfmuxdPerfTelecomBerLinePreFecPast24StatHistory Article |
| 1.3.6.1.4.1.20044.111.11.7.355.1 | Rowpm100gfmuxdPerfTelecomBerLinePreFecPast24StatHistoryPort1Entry | not-accessible | current | Row definition for the pm100gfmuxdPerfTelecomBerLinePreFecPast24StatHistory table |
| 1.3.6.1.4.1.20044.111.11.7.355.1.1 | Columnpm100gfmuxdPerfTelecomBerLinePreFecPast24StatHistoryPort1Index | read-only | current | Index definition for the pm100gfmuxdPerfTelecomBerLinePreFecPast24StatHistory table |
| 1.3.6.1.4.1.20044.111.11.7.355.1.2 | Columnpm100gfmuxdPerfTelecomBerLinePreFecPast24StatHistoryInvBerPort1 | read-only | current | Previous 24-hours BER counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.355.1.3 | Columnpm100gfmuxdPerfTelecomBerLinePreFecPast24StatHistoryBerValuePort1 | read-only | current | Previous 24-hours BER counter :This OID gives the previous 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.111.11.7.355.1.4 | Columnpm100gfmuxdPerfTelecomBerLinePreFecPast24StatHistoryInvMinBerPort1 | read-only | current | Previous 24-hours MinBER counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.355.1.5 | Columnpm100gfmuxdPerfTelecomBerLinePreFecPast24StatHistoryMinBerValuePort1 | read-only | current | Previous 24-hours MinBER counter :This OID gives the previous 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.111.11.7.355.1.6 | Columnpm100gfmuxdPerfTelecomBerLinePreFecPast24StatHistoryInvMaxBerPort1 | read-only | current | Previous 24-hours MaxBER counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.111.11.7.355.1.7 | Columnpm100gfmuxdPerfTelecomBerLinePreFecPast24StatHistoryMaxBerValuePort1 | read-only | current | Previous 24-hours MaxBER counter :This OID gives the previous 24-hours severely Errored Second counter value |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| Pm100gfmuxdModuleMode | INTEGER { modulemode2x40g(1), modulemode1x40g4x10g(2), modulemode10x10g(3) } | current | Different values on the module mode |