EKINOPS-Pm124-MIB
317 objects
MIB for the Ekinops Pm124 hardware.
Imported Objects
| EKINOPS-MIB | EkiApiState EkiMeasureType EkiMode ekinops EkiOnOff EkiProtocol EkiState EkiSynchroMode |
| SNMPv2-SMI | Counter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20044.16 | IdentitymodulePm124 | MIB for the Ekinops Pm124 hardware. | ||
| 1.3.6.1.4.1.20044.16.2 | Nodepm124alarms | |||
| 1.3.6.1.4.1.20044.16.2.1 | Nodepm124AlmOther | |||
| 1.3.6.1.4.1.20044.16.2.1.1 | Nodepm124AlmOtherNurg | |||
| 1.3.6.1.4.1.20044.16.2.1.1.2 | Nodepm124AlmsynthAlm2 | |||
| 1.3.6.1.4.1.20044.16.2.1.1.2.1 | Scalarpm124AlmConfTableSave | read-only | current | PM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> other… |
| 1.3.6.1.4.1.20044.16.2.1.1.2.2 | Scalarpm124AlmInvUpload | read-only | current | Inventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> other (1) <Alarmtype> other (1) <Polarit… |
| 1.3.6.1.4.1.20044.16.2.1.1.2.3 | Scalarpm124AlmConfTableLoad | read-only | current | PM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> other (1) <Alarmt… |
| 1.3.6.1.4.1.20044.16.2.1.1.2.4 | Scalarpm124AlmCorrelatOff | read-only | current | Not Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> other (1) <Alarmtype> other (1) <Pol… |
| 1.3.6.1.4.1.20044.16.2.1.2 | Nodepm124AlmOtherUrg | |||
| 1.3.6.1.4.1.20044.16.2.1.3 | Nodepm124AlmOtherCrit | |||
| 1.3.6.1.4.1.20044.16.2.1.3.0 | Nodepm124AlmsynthAlm0 | |||
| 1.3.6.1.4.1.20044.16.2.1.3.0.9 | Scalarpm124AlmModuleGlobFailure | read-only | current | Module Failure :This OID is set on detection of a failure originating from the PM <Condtype> MODULE_GLOB_FAILURE <Probcause> equipmentMalfunction (16) <Alarmty… |
| 1.3.6.1.4.1.20044.16.2.1.3.0.15 | Scalarpm124AlmDefFuseA | read-only | current | Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.16.2.1.3.0.16 | Scalarpm124AlmDefFuseB | read-only | current | Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.16.2.2 | Nodepm124AlmClient | |||
| 1.3.6.1.4.1.20044.16.2.2.1 | Nodepm124AlmClientNurg | |||
| 1.3.6.1.4.1.20044.16.2.2.1.32 | Tablepm124AlmclientSfpWarnDdmTable | not-accessible | current | List of pm124AlmclientSfpWarnDdm Article |
| 1.3.6.1.4.1.20044.16.2.2.1.32.1 | Rowpm124AlmclientSfpWarnDdmEntry | not-accessible | current | Row definition for the pm124AlmclientSfpWarnDdm table |
| 1.3.6.1.4.1.20044.16.2.2.1.32.1.1 | Columnpm124AlmclientSfpWarnDdmIndex | read-only | current | Index definition for the pm124AlmclientSfpWarnDdm table |
| 1.3.6.1.4.1.20044.16.2.2.1.32.1.2 | Columnpm124AlmClientTxPwLowWngPortn | read-only | current | Client SFP Tx Power Low Warning :Warning indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> CL… |
| 1.3.6.1.4.1.20044.16.2.2.1.32.1.3 | Columnpm124AlmClientTxPwrHighWngPortn | read-only | current | Client SFP Tx Power High Warning :Warning indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> … |
| 1.3.6.1.4.1.20044.16.2.2.1.32.1.4 | Columnpm124AlmClientTxBiasLowWngPortn | read-only | current | Client SFP Bias Low Warning :Warning indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> … |
| 1.3.6.1.4.1.20044.16.2.2.1.32.1.5 | Columnpm124AlmClientTxBiasHighWngPortn | read-only | current | Client SFP Bias High Warning :Warning indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype… |
| 1.3.6.1.4.1.20044.16.2.2.1.32.1.6 | Columnpm124AlmClientVccLowWngPortn | read-only | current | Client SFP Power Supply Low Warning :Warning indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype… |
| 1.3.6.1.4.1.20044.16.2.2.1.32.1.7 | Columnpm124AlmClientVccHighWngPortn | read-only | current | Client SFP Power Supply High Warning :Warning indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condty… |
| 1.3.6.1.4.1.20044.16.2.2.1.32.1.8 | Columnpm124AlmClientTempLowWngPortn | read-only | current | Client SFP Temp Low Warning :Warning indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_… |
| 1.3.6.1.4.1.20044.16.2.2.1.32.1.9 | Columnpm124AlmClientTempHighWngPortn | read-only | current | Client SFP Temp High Warning :Warning indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIEN… |
| 1.3.6.1.4.1.20044.16.2.2.1.32.1.16 | Columnpm124AlmClientRxPwrLowWngPortn | read-only | current | Client SFP Rx Power Low Warning :Warning indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLI… |
| 1.3.6.1.4.1.20044.16.2.2.1.32.1.17 | Columnpm124AlmClientRxPwrHighWngPortn | read-only | current | Client SFP Rx Power High Warning :Warning indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> C… |
| 1.3.6.1.4.1.20044.16.2.2.2 | Nodepm124AlmClientUrg | |||
| 1.3.6.1.4.1.20044.16.2.2.2.24 | Tablepm124AlmclientSfpAlmDdmTable | not-accessible | current | List of pm124AlmclientSfpAlmDdm Article |
| 1.3.6.1.4.1.20044.16.2.2.2.24.1 | Rowpm124AlmclientSfpAlmDdmEntry | not-accessible | current | Row definition for the pm124AlmclientSfpAlmDdm table |
| 1.3.6.1.4.1.20044.16.2.2.2.24.1.1 | Columnpm124AlmclientSfpAlmDdmIndex | read-only | current | Index definition for the pm124AlmclientSfpAlmDdm table |
| 1.3.6.1.4.1.20044.16.2.2.2.24.1.2 | Columnpm124AlmClientTxPwrLowAlaPortn | read-only | current | Client SFP Tx Power Low :Alarm indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_TX_PW… |
| 1.3.6.1.4.1.20044.16.2.2.2.24.1.3 | Columnpm124AlmClientClientTxPwrHighAlaPortn | read-only | current | Client SFP Tx Power High :Alarm indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIENT_CLI… |
| 1.3.6.1.4.1.20044.16.2.2.2.24.1.4 | Columnpm124AlmClientTxBiasLowAlaPortn | read-only | current | Client SFP Bias Low :Alarm indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_TX_… |
| 1.3.6.1.4.1.20044.16.2.2.2.24.1.5 | Columnpm124AlmClientTxBiasHighAlaPortn | read-only | current | Client SFP Bias High :Alarm indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIENT_T… |
| 1.3.6.1.4.1.20044.16.2.2.2.24.1.6 | Columnpm124AlmClientVccLowAlaPortn | read-only | current | Client SFP Power Supply Low :Alarm indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_V… |
| 1.3.6.1.4.1.20044.16.2.2.2.24.1.7 | Columnpm124AlmClientVccHighAlaPortn | read-only | current | Client SFP Power Supply High :Alarm indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIENT… |
| 1.3.6.1.4.1.20044.16.2.2.2.24.1.8 | Columnpm124AlmClientTempLowAlaPortn | read-only | current | Client SFP Temp Low :Alarm indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_TEMP_LOW_A… |
| 1.3.6.1.4.1.20044.16.2.2.2.24.1.9 | Columnpm124AlmClientTempHighAlaPortn | read-only | current | Client SFP Temp High :Alarm indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIENT_TEMP_HIG… |
| 1.3.6.1.4.1.20044.16.2.2.2.24.1.16 | Columnpm124AlmClientRxPwrLowAlaPortn | read-only | current | Client SFP Rx Power Low :Alarm indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_RX_PWR… |
| 1.3.6.1.4.1.20044.16.2.2.2.24.1.17 | Columnpm124AlmClientRxPwrHighAlaPortn | read-only | current | Client SFP Rx Power High :Alarm indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIENT_RX_P… |
| 1.3.6.1.4.1.20044.16.2.2.3 | Nodepm124AlmClientCrit | |||
| 1.3.6.1.4.1.20044.16.2.2.3.8 | Tablepm124AlmsynthAlmPortTable | not-accessible | current | List of pm124AlmsynthAlmPort Article |
| 1.3.6.1.4.1.20044.16.2.2.3.8.1 | Rowpm124AlmsynthAlmPortEntry | not-accessible | current | Row definition for the pm124AlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.16.2.2.3.8.1.1 | Columnpm124AlmsynthAlmPortIndex | read-only | current | Index definition for the pm124AlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.16.2.2.3.8.1.2 | Columnpm124AlmClientSfpAbsentPortn | read-only | current | Client SFP Absent :This OID indicates that the SFP module is not present in the client port. <Help> This alarm indicates if the client transceiver is present. … |
| 1.3.6.1.4.1.20044.16.2.2.3.8.1.3 | Columnpm124AlmClientDdmAbsentPortn | read-only | current | DDM Supported On Client SFP :This OID indicates that the Client SFP module does not support the Digital Diagnostic Monitoring function <Help> This status indic… |
| 1.3.6.1.4.1.20044.16.2.2.3.8.1.5 | Columnpm124AlmClientHwFailAccPortn | read-only | current | Client HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Condtype> CLIENT_HW_FAIL_ACC_1 <Probcause> equipmentMalfuncti… |
| 1.3.6.1.4.1.20044.16.2.2.3.8.1.6 | Columnpm124AlmClientLsdPortn | read-only | current | Client SFP Laser Shutdown :This OID indicates the Client SFP transmitter output has shut down. <Help> This status indicates if the client transceiver laser is … |
| 1.3.6.1.4.1.20044.16.2.2.3.8.1.7 | Columnpm124AlmClientLocalOosPortn | read-only | current | Local Client Port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local c… |
| 1.3.6.1.4.1.20044.16.2.2.3.8.1.8 | Columnpm124AlmClientRemoteOosPortn | read-only | current | Remote Client Port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the remot… |
| 1.3.6.1.4.1.20044.16.2.2.3.8.1.9 | Columnpm124AlmClientDwCaisPortn | read-only | current | Client AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indicates if a Client Alarm Indication Signal is… |
| 1.3.6.1.4.1.20044.16.2.2.3.8.1.10 | Columnpm124AlmClientSfpDdmWarningPortn | read-only | current | Warning On Client SFP DDM :This OID indicates a warning is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Warning has been detecte… |
| 1.3.6.1.4.1.20044.16.2.2.3.8.1.11 | Columnpm124AlmClientSfpDdmAlmPortn | read-only | current | Alarm On Client SFP DDM :This OID indicates an alarm is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Alarm has been detected on … |
| 1.3.6.1.4.1.20044.16.2.2.3.8.1.13 | Columnpm124AlmClientFailAccPortn | read-only | current | Client Access Fail :This OID indicates a failure on the Client port <Condtype> CLIENT_FAIL_ACC_1 <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAla… |
| 1.3.6.1.4.1.20044.16.2.2.3.8.1.17 | Columnpm124AlmClientUpCsfPortn | read-only | current | Client Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu… |
| 1.3.6.1.4.1.20044.16.2.2.3.16 | Tablepm124AlmclientAccessioAlmTable | not-accessible | current | List of pm124AlmclientAccessioAlm Article |
| 1.3.6.1.4.1.20044.16.2.2.3.16.1 | Rowpm124AlmclientAccessioAlmEntry | not-accessible | current | Row definition for the pm124AlmclientAccessioAlm table |
| 1.3.6.1.4.1.20044.16.2.2.3.16.1.1 | Columnpm124AlmclientAccessioAlmIndex | read-only | current | Index definition for the pm124AlmclientAccessioAlm table |
| 1.3.6.1.4.1.20044.16.2.2.3.16.1.2 | Columnpm124AlmClientLasFailPortn | read-only | current | Client SFP Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the client port (this alarm reports the transmitter failure alarm … |
| 1.3.6.1.4.1.20044.16.2.2.3.16.1.5 | Columnpm124AlmClientLosPortn | read-only | current | Loss Of Optical Signal On Client :This OID indicates that no signal is present on the SFP of the client port <Help> This alarm indicates if an optical signal i… |
| 1.3.6.1.4.1.20044.16.2.2.3.40 | Tablepm124AlmclientAccAlmTable | not-accessible | current | List of pm124AlmclientAccAlm Article |
| 1.3.6.1.4.1.20044.16.2.2.3.40.1 | Rowpm124AlmclientAccAlmEntry | not-accessible | current | Row definition for the pm124AlmclientAccAlm table |
| 1.3.6.1.4.1.20044.16.2.2.3.40.1.1 | Columnpm124AlmclientAccAlmIndex | read-only | current | Index definition for the pm124AlmclientAccAlm table |
| 1.3.6.1.4.1.20044.16.2.2.3.40.1.2 | Columnpm124AlmClientOosPortn | read-only | current | Client Loss Of Frame :This OID indicates that a Loss of Frame has been detected on the client input signal <Help> This alarm indicates if there is a Loss of Fr… |
| 1.3.6.1.4.1.20044.16.2.2.3.40.1.11 | Columnpm124AlmClientUpEsOvlPortn | read-only | current | Client Upstream Buffer Overload :This OID indicates that the rate adaptation buffer for client port is in overload. <Help> This alarm indicates if there is a u… |
| 1.3.6.1.4.1.20044.16.2.2.3.40.1.12 | Columnpm124AlmClientCsfDetPortn | read-only | current | Client Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client… |
| 1.3.6.1.4.1.20044.16.2.2.3.40.1.15 | Columnpm124AlmClientDwEsOvlPortn | read-only | current | Client Downstream Buffer Overload :This OID indicates that the de-mapper buffer for client port is in overload. <Help> This alarm indicates if there is a downs… |
| 1.3.6.1.4.1.20044.16.2.3 | Nodepm124AlmLine | |||
| 1.3.6.1.4.1.20044.16.2.3.1 | Nodepm124AlmLineNurg | |||
| 1.3.6.1.4.1.20044.16.2.3.1.66 | Tablepm124AlmlineSfpWarnDdmTable | not-accessible | current | List of pm124AlmlineSfpWarnDdm Article |
| 1.3.6.1.4.1.20044.16.2.3.1.66.1 | Rowpm124AlmlineSfpWarnDdmEntry | not-accessible | current | Row definition for the pm124AlmlineSfpWarnDdm table |
| 1.3.6.1.4.1.20044.16.2.3.1.66.1.1 | Columnpm124AlmlineSfpWarnDdmIndex | read-only | current | Index definition for the pm124AlmlineSfpWarnDdm table |
| 1.3.6.1.4.1.20044.16.2.3.1.66.1.2 | Columnpm124AlmLineTxPwLowWngPortn | read-only | current | Line SFP Tx Power Low Warning :Warning indicating that the SFP output power of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE… |
| 1.3.6.1.4.1.20044.16.2.3.1.66.1.3 | Columnpm124AlmLineTxPwrHighWngPortn | read-only | current | Line SFP Tx Power High Warning :Warning indicating that the SFP output power of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LI… |
| 1.3.6.1.4.1.20044.16.2.3.1.66.1.4 | Columnpm124AlmLineTxBiasLowWngPortn | read-only | current | Line SFP Bias Low Warning :Warning indicating that the SFP laser bias current of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LI… |
| 1.3.6.1.4.1.20044.16.2.3.1.66.1.5 | Columnpm124AlmLineTxBiasHighWngPortn | read-only | current | Line SFP Bias High Warning :Warning indicating that the SFP laser bias current of Line is higher than the threshold value written in the SFP EEPROM <Condtype> … |
| 1.3.6.1.4.1.20044.16.2.3.1.66.1.6 | Columnpm124AlmLineVccLowWngPortn | read-only | current | Line SFP Power Supply Low Warning :Warning indicating that the SFP power supply of Line is lower than the threshold value written in the SFP EEPROM <Condtype> … |
| 1.3.6.1.4.1.20044.16.2.3.1.66.1.7 | Columnpm124AlmLineVccHighWngPortn | read-only | current | Line SFP Power Supply High Warning :Warning indicating that the SFP power supply of Line is higher than the threshold value written in the SFP EEPROM <Condtype… |
| 1.3.6.1.4.1.20044.16.2.3.1.66.1.8 | Columnpm124AlmLineTempLowWngPortn | read-only | current | Line SFP Temp Low Warning :Warning indicating that the SFP temperature of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_TEMP… |
| 1.3.6.1.4.1.20044.16.2.3.1.66.1.9 | Columnpm124AlmLineTempHighWngPortn | read-only | current | Line SFP Temp High Warning :Warning indicating that the SFP temperature of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_TE… |
| 1.3.6.1.4.1.20044.16.2.3.1.66.1.16 | Columnpm124AlmLineRxPwrLowWngPortn | read-only | current | Line SFP Rx Power Low Warning :Warning indicating that the SFP input power of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_… |
| 1.3.6.1.4.1.20044.16.2.3.1.66.1.17 | Columnpm124AlmLineRxPwrHighWngPortn | read-only | current | Line SFP Rx Power High Warning :Warning indicating that the SFP input power of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LIN… |
| 1.3.6.1.4.1.20044.16.2.3.2 | Nodepm124AlmLineUrg | |||
| 1.3.6.1.4.1.20044.16.2.3.2.65 | Tablepm124AlmlineSfpAlmDdmTable | not-accessible | current | List of pm124AlmlineSfpAlmDdm Article |
| 1.3.6.1.4.1.20044.16.2.3.2.65.1 | Rowpm124AlmlineSfpAlmDdmEntry | not-accessible | current | Row definition for the pm124AlmlineSfpAlmDdm table |
| 1.3.6.1.4.1.20044.16.2.3.2.65.1.1 | Columnpm124AlmlineSfpAlmDdmIndex | read-only | current | Index definition for the pm124AlmlineSfpAlmDdm table |
| 1.3.6.1.4.1.20044.16.2.3.2.65.1.2 | Columnpm124AlmLineTxPwrLowAlaPortn | read-only | current | Line SFP Tx Power Low :Alarm indicating that the SFP output power of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_TX_PWR_LO… |
| 1.3.6.1.4.1.20044.16.2.3.2.65.1.3 | Columnpm124AlmLineTxPwrHighAlaPortn | read-only | current | Line SFP Tx Power High :Alarm indicating that the SFP output power of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_TX_PWR_… |
| 1.3.6.1.4.1.20044.16.2.3.2.65.1.4 | Columnpm124AlmLineTxBiasLowAlaPortn | read-only | current | Line SFP Bias Low :Alarm indicating that the SFP laser bias current of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_TX_BIAS… |
| 1.3.6.1.4.1.20044.16.2.3.2.65.1.5 | Columnpm124AlmLineTxBiasHighAlaPortn | read-only | current | Line SFP Bias High :Alarm indicating that the SFP laser bias current of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_TX_BI… |
| 1.3.6.1.4.1.20044.16.2.3.2.65.1.6 | Columnpm124AlmLineVccLowAlaPortn | read-only | current | Line SFP Power Supply Low :Alarm indicating that the SFP power supply of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_VCC_L… |
| 1.3.6.1.4.1.20044.16.2.3.2.65.1.7 | Columnpm124AlmLineVccHighAlaPortn | read-only | current | Line SFP Power Supply High :Alarm indicating that the SFP power supply of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_VCC… |
| 1.3.6.1.4.1.20044.16.2.3.2.65.1.8 | Columnpm124AlmLineTempLowAlaPortn | read-only | current | Line SFP Temp Low :Alarm indicating that the SFP temperature of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_TEMP_LOW_ALA <… |
| 1.3.6.1.4.1.20044.16.2.3.2.65.1.9 | Columnpm124AlmLineTempHighAlaPortn | read-only | current | Line SFP Temp High :Alarm indicating that the SFP temperature of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_TEMP_HIGH_AL… |
| 1.3.6.1.4.1.20044.16.2.3.2.65.1.16 | Columnpm124AlmLineRxPwrLowAlaPortn | read-only | current | Line SFP Rx Power Low :Alarm indicating that the SFP input power of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_RX_PWR_LOW… |
| 1.3.6.1.4.1.20044.16.2.3.2.65.1.17 | Columnpm124AlmLineRxPwrHighAlaPortn | read-only | current | Line SFP Rx Power High :Alarm indicating that the SFP input power of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_RX_PWR_H… |
| 1.3.6.1.4.1.20044.16.2.3.3 | Nodepm124AlmLineCrit | |||
| 1.3.6.1.4.1.20044.16.2.3.3.7 | Tablepm124AlmsynthAlmLineTable | not-accessible | current | List of pm124AlmsynthAlmLine Article |
| 1.3.6.1.4.1.20044.16.2.3.3.7.1 | Rowpm124AlmsynthAlmLineEntry | not-accessible | current | Row definition for the pm124AlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.16.2.3.3.7.1.1 | Columnpm124AlmsynthAlmLineIndex | read-only | current | Index definition for the pm124AlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.16.2.3.3.7.1.2 | Columnpm124AlmLineSfpAbsentPortn | read-only | current | Line SFP Absent :This OID indicates that the SFP module is not present in the line port. <Help> This alarm indicates if the line transceiver is present. <Condt… |
| 1.3.6.1.4.1.20044.16.2.3.3.7.1.3 | Columnpm124AlmLineDdmAbsentPortn | read-only | current | DDM Supported On Line SFP :This OID indicates that the SFP module on line port does not support Digital Diagnostic Monitoring Functions <Help> This status indi… |
| 1.3.6.1.4.1.20044.16.2.3.3.7.1.5 | Columnpm124AlmLineHwFailPortn | read-only | current | Line HW Fail :This OID indicates a failure condition on the Line port, the most probable cause being a HW issue <Condtype> LINE_HW_FAIL <Probcause> equipmentMa… |
| 1.3.6.1.4.1.20044.16.2.3.3.7.1.6 | Columnpm124AlmLineLsdPortn | read-only | current | Line SFP Laser Shutdown :This OID indicates the Client SFP transmitter output has shut down. <Help> This status indicates if the line transceiver laser is ON o… |
| 1.3.6.1.4.1.20044.16.2.3.3.7.1.7 | Columnpm124AlmLineLocalOosPortn | read-only | current | Line Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service… |
| 1.3.6.1.4.1.20044.16.2.3.3.7.1.10 | Columnpm124AlmLineDdmWarningPortn | read-only | current | Warning On Line SFP DDM :This OID indicates a warning is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Warning has been detected … |
| 1.3.6.1.4.1.20044.16.2.3.3.7.1.11 | Columnpm124AlmLineDdmAlmPortn | read-only | current | Alarm On Line SFP DDM :This OID indicates an alarm is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Alarm has been detected on th… |
| 1.3.6.1.4.1.20044.16.2.3.3.7.1.13 | Columnpm124AlmLineFailPortn | read-only | current | Line Fail :This OID indicates a failure on the Client port <Condtype> LINE_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12) <Polarity… |
| 1.3.6.1.4.1.20044.16.2.3.3.64 | Tablepm124AlmlineAccessioAlmTable | not-accessible | current | List of pm124AlmlineAccessioAlm Article |
| 1.3.6.1.4.1.20044.16.2.3.3.64.1 | Rowpm124AlmlineAccessioAlmEntry | not-accessible | current | Row definition for the pm124AlmlineAccessioAlm table |
| 1.3.6.1.4.1.20044.16.2.3.3.64.1.1 | Columnpm124AlmlineAccessioAlmIndex | read-only | current | Index definition for the pm124AlmlineAccessioAlm table |
| 1.3.6.1.4.1.20044.16.2.3.3.64.1.2 | Columnpm124AlmLineLasFailPortn | read-only | current | Line SFP Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the line port (this alarm reports the transmitter failure alarm gene… |
| 1.3.6.1.4.1.20044.16.2.3.3.64.1.5 | Columnpm124AlmLineLosPortn | read-only | current | Loss Of Optical Signal On Line :This OID indicates that no signal is present on the SFP of the line port <Help> This alarm indicates if an optical signal is de… |
| 1.3.6.1.4.1.20044.16.2.3.3.64.1.7 | Columnpm124AlmLineLossSyncPortn | read-only | current | Line Loss Of 10b/8b Synchro :This OID indicates the upstream line input port has lost synchronization on its 10B/8B decoder <Help> This alarms indicates if the… |
| 1.3.6.1.4.1.20044.16.3 | Nodepm124measures | |||
| 1.3.6.1.4.1.20044.16.3.1 | Nodepm124MesrOther | |||
| 1.3.6.1.4.1.20044.16.3.2 | Nodepm124MesrClient | |||
| 1.3.6.1.4.1.20044.16.3.2.16 | Tablepm124MesrclientTemperatureTable | not-accessible | current | List of pm124MesrclientTemperature Article |
| 1.3.6.1.4.1.20044.16.3.2.16.1 | Rowpm124MesrclientTemperatureEntry | not-accessible | current | Row definition for the pm124MesrclientTemperature table |
| 1.3.6.1.4.1.20044.16.3.2.16.1.1 | Columnpm124MesrclientTemperatureIndex | read-only | current | Index definition for the pm124MesrclientTemperature table |
| 1.3.6.1.4.1.20044.16.3.2.16.1.2 | Columnpm124MesrclientTemperaturePortn | read-only | current | Client SFP Temperature :This OID gives the temperature value of the client SFP, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit … |
| 1.3.6.1.4.1.20044.16.3.2.24 | Tablepm124MesrclientVoltTable | not-accessible | current | List of pm124MesrclientVolt Article |
| 1.3.6.1.4.1.20044.16.3.2.24.1 | Rowpm124MesrclientVoltEntry | not-accessible | current | Row definition for the pm124MesrclientVolt table |
| 1.3.6.1.4.1.20044.16.3.2.24.1.1 | Columnpm124MesrclientVoltIndex | read-only | current | Index definition for the pm124MesrclientVolt table |
| 1.3.6.1.4.1.20044.16.3.2.24.1.2 | Columnpm124MesrclientVoltPortn | read-only | current | Client SFP Power Supply :This OID gives the 3V3 voltage value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/100… |
| 1.3.6.1.4.1.20044.16.3.2.32 | Tablepm124MesrclientTxBiasTable | not-accessible | current | List of pm124MesrclientTxBias Article |
| 1.3.6.1.4.1.20044.16.3.2.32.1 | Rowpm124MesrclientTxBiasEntry | not-accessible | current | Row definition for the pm124MesrclientTxBias table |
| 1.3.6.1.4.1.20044.16.3.2.32.1.1 | Columnpm124MesrclientTxBiasIndex | read-only | current | Index definition for the pm124MesrclientTxBias table |
| 1.3.6.1.4.1.20044.16.3.2.32.1.2 | Columnpm124MesrclientTxBiasPortn | read-only | current | Client SFP Laser Bias :This OID gives the bias value of the Client SFP, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <Help> Th… |
| 1.3.6.1.4.1.20044.16.3.2.40 | Tablepm124MesrclientTxPowerTable | not-accessible | current | List of pm124MesrclientTxPower Article |
| 1.3.6.1.4.1.20044.16.3.2.40.1 | Rowpm124MesrclientTxPowerEntry | not-accessible | current | Row definition for the pm124MesrclientTxPower table |
| 1.3.6.1.4.1.20044.16.3.2.40.1.1 | Columnpm124MesrclientTxPowerIndex | read-only | current | Index definition for the pm124MesrclientTxPower table |
| 1.3.6.1.4.1.20044.16.3.2.40.1.2 | Columnpm124MesrclientTxPowerPortn | read-only | current | Client SFP Tx Power :This OID gives the transmit power value of the Client SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit… |
| 1.3.6.1.4.1.20044.16.3.2.48 | Tablepm124MesrclientRxPowerTable | not-accessible | current | List of pm124MesrclientRxPower Article |
| 1.3.6.1.4.1.20044.16.3.2.48.1 | Rowpm124MesrclientRxPowerEntry | not-accessible | current | Row definition for the pm124MesrclientRxPower table |
| 1.3.6.1.4.1.20044.16.3.2.48.1.1 | Columnpm124MesrclientRxPowerIndex | read-only | current | Index definition for the pm124MesrclientRxPower table |
| 1.3.6.1.4.1.20044.16.3.2.48.1.2 | Columnpm124MesrclientRxPowerPortn | read-only | current | Client SFP Rx Power :This OID gives the receive power value of the Client SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = … |
| 1.3.6.1.4.1.20044.16.3.3 | Nodepm124MesrLine | |||
| 1.3.6.1.4.1.20044.16.3.3.64 | Tablepm124MesrlineTemperatureTable | not-accessible | current | List of pm124MesrlineTemperature Article |
| 1.3.6.1.4.1.20044.16.3.3.64.1 | Rowpm124MesrlineTemperatureEntry | not-accessible | current | Row definition for the pm124MesrlineTemperature table |
| 1.3.6.1.4.1.20044.16.3.3.64.1.1 | Columnpm124MesrlineTemperatureIndex | read-only | current | Index definition for the pm124MesrlineTemperature table |
| 1.3.6.1.4.1.20044.16.3.3.64.1.2 | Columnpm124MesrlineTemperaturePortn | read-only | current | Line SFP Temperature :This OID gives the temperature value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit = C)… |
| 1.3.6.1.4.1.20044.16.3.3.65 | Tablepm124MesrlineVoltTable | not-accessible | current | List of pm124MesrlineVolt Article |
| 1.3.6.1.4.1.20044.16.3.3.65.1 | Rowpm124MesrlineVoltEntry | not-accessible | current | Row definition for the pm124MesrlineVolt table |
| 1.3.6.1.4.1.20044.16.3.3.65.1.1 | Columnpm124MesrlineVoltIndex | read-only | current | Index definition for the pm124MesrlineVolt table |
| 1.3.6.1.4.1.20044.16.3.3.65.1.2 | Columnpm124MesrlineVoltPortn | read-only | current | Line SFP Power Supply :This OID gives the 3V3 voltage value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/10000) (Unit = V) … |
| 1.3.6.1.4.1.20044.16.3.3.66 | Tablepm124MesrlineTxBiasTable | not-accessible | current | List of pm124MesrlineTxBias Article |
| 1.3.6.1.4.1.20044.16.3.3.66.1 | Rowpm124MesrlineTxBiasEntry | not-accessible | current | Row definition for the pm124MesrlineTxBias table |
| 1.3.6.1.4.1.20044.16.3.3.66.1.1 | Columnpm124MesrlineTxBiasIndex | read-only | current | Index definition for the pm124MesrlineTxBias table |
| 1.3.6.1.4.1.20044.16.3.3.66.1.2 | Columnpm124MesrlineTxBiasPortn | read-only | current | Line SFP Laser Bias :This OID gives the bias value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <Help> This m… |
| 1.3.6.1.4.1.20044.16.3.3.67 | Tablepm124MesrlineTxPowerTable | not-accessible | current | List of pm124MesrlineTxPower Article |
| 1.3.6.1.4.1.20044.16.3.3.67.1 | Rowpm124MesrlineTxPowerEntry | not-accessible | current | Row definition for the pm124MesrlineTxPower table |
| 1.3.6.1.4.1.20044.16.3.3.67.1.1 | Columnpm124MesrlineTxPowerIndex | read-only | current | Index definition for the pm124MesrlineTxPower table |
| 1.3.6.1.4.1.20044.16.3.3.67.1.2 | Columnpm124MesrlineTxPowerPortn | read-only | current | Line SFP Tx Power :This OID gives the transmit power value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = d… |
| 1.3.6.1.4.1.20044.16.3.3.68 | Tablepm124MesrlineRxPowerTable | not-accessible | current | List of pm124MesrlineRxPower Article |
| 1.3.6.1.4.1.20044.16.3.3.68.1 | Rowpm124MesrlineRxPowerEntry | not-accessible | current | Row definition for the pm124MesrlineRxPower table |
| 1.3.6.1.4.1.20044.16.3.3.68.1.1 | Columnpm124MesrlineRxPowerIndex | read-only | current | Index definition for the pm124MesrlineRxPower table |
| 1.3.6.1.4.1.20044.16.3.3.68.1.2 | Columnpm124MesrlineRxPowerPortn | read-only | current | Line SFP Rx Power :This OID gives the receive power value of the Line SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm)… |
| 1.3.6.1.4.1.20044.16.4 | Nodepm124counters | |||
| 1.3.6.1.4.1.20044.16.4.1 | Nodepm124CntOther | |||
| 1.3.6.1.4.1.20044.16.4.2 | Nodepm124CntClient | |||
| 1.3.6.1.4.1.20044.16.4.2.16 | Tablepm124CntclientCbipErrCntTable | not-accessible | current | List of pm124CntclientCbipErrCnt Article |
| 1.3.6.1.4.1.20044.16.4.2.16.1 | Rowpm124CntclientCbipErrCntEntry | not-accessible | current | Row definition for the pm124CntclientCbipErrCnt table |
| 1.3.6.1.4.1.20044.16.4.2.16.1.1 | Columnpm124CntclientCbipErrCntIndex | read-only | current | Index definition for the pm124CntclientCbipErrCnt table |
| 1.3.6.1.4.1.20044.16.4.2.16.1.2 | Columnpm124CntclientCbipErrCntValuePortn | read-only | current | Client Output Errors (Err Sec) :This counter is incremented by one each time one or several CBIP parity error is detected during one second on the client outpu… |
| 1.3.6.1.4.1.20044.16.4.2.16.1.3 | Columnpm124CntclientCbipErrCntErrorPortn | read-only | current | Client CBIP counter error :This OID when set indicates the CBIP error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.16.4.2.16.1.4 | Columnpm124CntclientCbipErrCntOverloadPortn | read-only | current | Client CBIP counter overload :This OID when set indicates a CBIP error counter overload on Port |
| 1.3.6.1.4.1.20044.16.4.2.24 | Tablepm124CntclientB1ErrCntTable | not-accessible | current | List of pm124CntclientB1ErrCnt Article |
| 1.3.6.1.4.1.20044.16.4.2.24.1 | Rowpm124CntclientB1ErrCntEntry | not-accessible | current | Row definition for the pm124CntclientB1ErrCnt table |
| 1.3.6.1.4.1.20044.16.4.2.24.1.1 | Columnpm124CntclientB1ErrCntIndex | read-only | current | Index definition for the pm124CntclientB1ErrCnt table |
| 1.3.6.1.4.1.20044.16.4.2.24.1.2 | Columnpm124CntclientB1ErrCntValuePortn | read-only | current | Client Input Errors (Err Sec) :This counter is incremented by one each time one or several B1 error is detected during one second on the client input stream <H… |
| 1.3.6.1.4.1.20044.16.4.2.24.1.3 | Columnpm124CntclientB1ErrCntErrorPortn | read-only | current | Client B1 counter error :This OID when set indicates the B1 counter value is invalid on Port |
| 1.3.6.1.4.1.20044.16.4.2.24.1.4 | Columnpm124CntclientB1ErrCntOverloadPortn | read-only | current | Client B1 counter overload :This OID when set indicates a B1 counter overload on Port |
| 1.3.6.1.4.1.20044.16.4.3 | Nodepm124CntLine | |||
| 1.3.6.1.4.1.20044.16.4.3.64 | Tablepm124CntlineDispErrCntTable | not-accessible | current | List of pm124CntlineDispErrCnt Article |
| 1.3.6.1.4.1.20044.16.4.3.64.1 | Rowpm124CntlineDispErrCntEntry | not-accessible | current | Row definition for the pm124CntlineDispErrCnt table |
| 1.3.6.1.4.1.20044.16.4.3.64.1.1 | Columnpm124CntlineDispErrCntIndex | read-only | current | Index definition for the pm124CntlineDispErrCnt table |
| 1.3.6.1.4.1.20044.16.4.3.64.1.2 | Columnpm124CntlineDispErrCntValuePortn | read-only | current | Line RD errors (Err Sec) :This counter is in incremented by one each time one or several 10b/8b running disparity error is detected during one second on the Li… |
| 1.3.6.1.4.1.20044.16.4.3.64.1.3 | Columnpm124CntlineDispErrCntErrorPortn | read-only | current | Line counter error :This OID when set indicates the line error counter value is invalid on Line |
| 1.3.6.1.4.1.20044.16.4.3.64.1.4 | Columnpm124CntlineDispErrCntOverloadPortn | read-only | current | Line counter overload :This OID when set indicates a line input error counter overload on Line |
| 1.3.6.1.4.1.20044.16.4.3.65 | Tablepm124CntlineCrcErrCntTable | not-accessible | current | List of pm124CntlineCrcErrCnt Article |
| 1.3.6.1.4.1.20044.16.4.3.65.1 | Rowpm124CntlineCrcErrCntEntry | not-accessible | current | Row definition for the pm124CntlineCrcErrCnt table |
| 1.3.6.1.4.1.20044.16.4.3.65.1.1 | Columnpm124CntlineCrcErrCntIndex | read-only | current | Index definition for the pm124CntlineCrcErrCnt table |
| 1.3.6.1.4.1.20044.16.4.3.65.1.2 | Columnpm124CntlineCrcErrCntValuePortn | read-only | current | Line Input Errors (Err Sec) :This counter is incremented by one each time one or several CRC error is detected during one second on the Line port <Help> This c… |
| 1.3.6.1.4.1.20044.16.4.3.65.1.3 | Columnpm124CntlineCrcErrCntErrorPortn | read-only | current | CRC Errors counter error :This OID when set indicates the CRC Errors counter value is invalid on line port |
| 1.3.6.1.4.1.20044.16.4.3.65.1.4 | Columnpm124CntlineCrcErrCntOverloadPortn | read-only | current | CRC Errors counter overload :This OID when set indicates a CRC Errors counter overload on line port |
| 1.3.6.1.4.1.20044.16.4.259 | Scalarpm124CntCountersReset | read-write | current | Counters Reset:This OID resets and restarts all the counters |
| 1.3.6.1.4.1.20044.16.4.260 | Scalarpm124CntCountersStop | read-write | current | Counters stop:This OID stops all the counters |
| 1.3.6.1.4.1.20044.16.6 | Nodepm124controlsWrite | |||
| 1.3.6.1.4.1.20044.16.6.1 | Nodepm124CtrlOther | |||
| 1.3.6.1.4.1.20044.16.6.1.0 | Nodepm124Ctrlsynth0 | |||
| 1.3.6.1.4.1.20044.16.6.1.0.1 | Scalarpm124CtrlConfLoad | read-write | current | Load Configuration Tables :When set this enables loading from flash configuration1 into the module. |
| 1.3.6.1.4.1.20044.16.6.1.0.9 | Scalarpm124CtrlConfFlash | read-write | current | Write Configuration Tables :This bit saves the current configuration of the module as configuration in the flash. <Help> This control saves the customer config… |
| 1.3.6.1.4.1.20044.16.6.1.0.13 | Scalarpm124CtrlConfClear | read-write | current | Clear Configuration Tables :This bit clears the configuration tables from configuration in the flash. <Help> This control restores the default configuration of… |
| 1.3.6.1.4.1.20044.16.6.1.4 | Nodepm124Ctrlsynth4 | |||
| 1.3.6.1.4.1.20044.16.6.1.4.1 | Scalarpm124CtrlCorrelatOn | read-write | current | Enable Alarm Correlation :This OID enables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.16.6.1.4.2 | Scalarpm124CtrlCorrelatOff | read-write | current | Disable Alarm Correlation :This OID disables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.16.6.1.5 | Nodepm124CtrlswMgnt | |||
| 1.3.6.1.4.1.20044.16.6.1.5.2 | Scalarpm124CtrlColdReset | read-write | current | PM Cold Reset :This OID, when set, causes a cold reset of the Software. This reset is traffic affecting, and the configuration of Software is reloaded on start… |
| 1.3.6.1.4.1.20044.16.6.1.5.3 | Scalarpm124CtrlWarmReset | read-write | current | PM Warm Reset :This OID, when set, causes a warm reset of the Software. This reset is not traffic affecting, and the configuration of the Sofwtare remains unch… |
| 1.3.6.1.4.1.20044.16.6.1.41 | Scalarpm124Ctrlprotocol | read-write | current | Client Ports Protocol :This OID sets the protocol of the Client port <Help> This control defines the protocol of the client port (1xSTM4/OC12 or 4xSTM1/OC3) |
| 1.3.6.1.4.1.20044.16.6.1.72 | Nodepm124CtrlledTest | |||
| 1.3.6.1.4.1.20044.16.6.1.72.1 | Scalarpm124CtrlGreenLed | read-write | current | Green Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green |
| 1.3.6.1.4.1.20044.16.6.1.72.2 | Scalarpm124CtrlRedLed | read-write | current | Red Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red |
| 1.3.6.1.4.1.20044.16.6.1.72.3 | Scalarpm124CtrlLedOff | read-write | current | Leds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF |
| 1.3.6.1.4.1.20044.16.6.1.73 | Nodepm124CtrlmoduleOosMode | |||
| 1.3.6.1.4.1.20044.16.6.1.73.1 | Scalarpm124CtrlModuleOosMode | read-write | current | PM Out Of Service :This OID sets the PM Out Of Service <Help> This control defines the service state of the complete module |
| 1.3.6.1.4.1.20044.16.6.2 | Nodepm124CtrlClient | |||
| 1.3.6.1.4.1.20044.16.6.2.16 | Tablepm124CtrlclientSfpOnoffTable | not-accessible | current | List of pm124CtrlclientSfpOnoff Article |
| 1.3.6.1.4.1.20044.16.6.2.16.1 | Rowpm124CtrlclientSfpOnoffEntry | not-accessible | current | Row definition for the pm124CtrlclientSfpOnoff table |
| 1.3.6.1.4.1.20044.16.6.2.16.1.1 | Columnpm124CtrlclientSfpOnoffIndex | read-only | current | Index definition for the pm124CtrlclientSfpOnoff table |
| 1.3.6.1.4.1.20044.16.6.2.16.1.2 | Columnpm124CtrlclientSfpOnoffPortn | read-write | current | Client SFP Laser Shutdown :This OID switches off the clients SFP <Help> This control defines the laser state of the client transceiver |
| 1.3.6.1.4.1.20044.16.6.2.17 | Tablepm124CtrlclientLoopTable | not-accessible | current | List of pm124CtrlclientLoop Article |
| 1.3.6.1.4.1.20044.16.6.2.17.1 | Rowpm124CtrlclientLoopEntry | not-accessible | current | Row definition for the pm124CtrlclientLoop table |
| 1.3.6.1.4.1.20044.16.6.2.17.1.1 | Columnpm124CtrlclientLoopIndex | read-only | current | Index definition for the pm124CtrlclientLoop table |
| 1.3.6.1.4.1.20044.16.6.2.17.1.2 | Columnpm124CtrlclientLoopPortn | read-write | current | Client Facility Loopback :This OID operates a Client Facility Loopback, looping client input signal on the client output port. The loop is located on the clien… |
| 1.3.6.1.4.1.20044.16.6.2.18 | Tablepm124CtrlclientCsfUpInsertTable | not-accessible | current | List of pm124CtrlclientCsfUpInsert Article |
| 1.3.6.1.4.1.20044.16.6.2.18.1 | Rowpm124CtrlclientCsfUpInsertEntry | not-accessible | current | Row definition for the pm124CtrlclientCsfUpInsert table |
| 1.3.6.1.4.1.20044.16.6.2.18.1.1 | Columnpm124CtrlclientCsfUpInsertIndex | read-only | current | Index definition for the pm124CtrlclientCsfUpInsert table |
| 1.3.6.1.4.1.20044.16.6.2.18.1.2 | Columnpm124CtrlclientCsfUpInsertPortn | read-write | current | Client Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. |
| 1.3.6.1.4.1.20044.16.6.2.19 | Tablepm124CtrlclientCaisDwInsertTable | not-accessible | current | List of pm124CtrlclientCaisDwInsert Article |
| 1.3.6.1.4.1.20044.16.6.2.19.1 | Rowpm124CtrlclientCaisDwInsertEntry | not-accessible | current | Row definition for the pm124CtrlclientCaisDwInsert table |
| 1.3.6.1.4.1.20044.16.6.2.19.1.1 | Columnpm124CtrlclientCaisDwInsertIndex | read-only | current | Index definition for the pm124CtrlclientCaisDwInsert table |
| 1.3.6.1.4.1.20044.16.6.2.19.1.2 | Columnpm124CtrlclientCaisDwInsertPortn | read-write | current | Client AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. |
| 1.3.6.1.4.1.20044.16.6.2.20 | Tablepm124CtrlclientOosModeTable | not-accessible | current | List of pm124CtrlclientOosMode Article |
| 1.3.6.1.4.1.20044.16.6.2.20.1 | Rowpm124CtrlclientOosModeEntry | not-accessible | current | Row definition for the pm124CtrlclientOosMode table |
| 1.3.6.1.4.1.20044.16.6.2.20.1.1 | Columnpm124CtrlclientOosModeIndex | read-only | current | Index definition for the pm124CtrlclientOosMode table |
| 1.3.6.1.4.1.20044.16.6.2.20.1.2 | Columnpm124CtrlclientOosModePortn | read-write | current | Client Port Out Of Service :This OID sets the client port Out Of Service <Help> This controls defines the service state of the client port |
| 1.3.6.1.4.1.20044.16.6.2.21 | Tablepm124CtrlclientAccessTermLoopTable | not-accessible | current | List of pm124CtrlclientAccessTermLoop Article |
| 1.3.6.1.4.1.20044.16.6.2.21.1 | Rowpm124CtrlclientAccessTermLoopEntry | not-accessible | current | Row definition for the pm124CtrlclientAccessTermLoop table |
| 1.3.6.1.4.1.20044.16.6.2.21.1.1 | Columnpm124CtrlclientAccessTermLoopIndex | read-only | current | Index definition for the pm124CtrlclientAccessTermLoop table |
| 1.3.6.1.4.1.20044.16.6.2.21.1.2 | Columnpm124CtrlclientAccessTermLoopPortn | read-write | current | Client Terminal Loopback :This OID operates a Client Terminal Loopback, looping client input signal on the client output port. The loop is located on the line … |
| 1.3.6.1.4.1.20044.16.6.3 | Nodepm124CtrlLine | |||
| 1.3.6.1.4.1.20044.16.6.3.64 | Tablepm124CtrllineSfpOnoffTable | not-accessible | current | List of pm124CtrllineSfpOnoff Article |
| 1.3.6.1.4.1.20044.16.6.3.64.1 | Rowpm124CtrllineSfpOnoffEntry | not-accessible | current | Row definition for the pm124CtrllineSfpOnoff table |
| 1.3.6.1.4.1.20044.16.6.3.64.1.1 | Columnpm124CtrllineSfpOnoffIndex | read-only | current | Index definition for the pm124CtrllineSfpOnoff table |
| 1.3.6.1.4.1.20044.16.6.3.64.1.2 | Columnpm124CtrllineSfpOnoffPortn | read-write | current | Line SFP Laser Shutdown :This OID switches off the line SFP <Help> This control defines the laser state of the line transceiver |
| 1.3.6.1.4.1.20044.16.6.3.65 | Tablepm124CtrllineOosModeTable | not-accessible | current | List of pm124CtrllineOosMode Article |
| 1.3.6.1.4.1.20044.16.6.3.65.1 | Rowpm124CtrllineOosModeEntry | not-accessible | current | Row definition for the pm124CtrllineOosMode table |
| 1.3.6.1.4.1.20044.16.6.3.65.1.1 | Columnpm124CtrllineOosModeIndex | read-only | current | Index definition for the pm124CtrllineOosMode table |
| 1.3.6.1.4.1.20044.16.6.3.65.1.2 | Columnpm124CtrllineOosModePortn | read-write | current | Line Port Out Of Service :This OID sets the line port Out Of Service <Help> This controls defines the service state of the line port |
| 1.3.6.1.4.1.20044.16.6.3.66 | Tablepm124CtrllineLoopTable | not-accessible | current | List of pm124CtrllineLoop Article |
| 1.3.6.1.4.1.20044.16.6.3.66.1 | Rowpm124CtrllineLoopEntry | not-accessible | current | Row definition for the pm124CtrllineLoop table |
| 1.3.6.1.4.1.20044.16.6.3.66.1.1 | Columnpm124CtrllineLoopIndex | read-only | current | Index definition for the pm124CtrllineLoop table |
| 1.3.6.1.4.1.20044.16.6.3.66.1.2 | Columnpm124CtrllineLoopPortn | read-write | current | Line Facility Loopback :This OID operates a Line Facility Loopback, looping line input signal on the line output port. The loop is located on the line transcei… |
| 1.3.6.1.4.1.20044.16.6.3.67 | Tablepm124CtrllineLoopTerminalTable | not-accessible | current | List of pm124CtrllineLoopTerminal Article |
| 1.3.6.1.4.1.20044.16.6.3.67.1 | Rowpm124CtrllineLoopTerminalEntry | not-accessible | current | Row definition for the pm124CtrllineLoopTerminal table |
| 1.3.6.1.4.1.20044.16.6.3.67.1.1 | Columnpm124CtrllineLoopTerminalIndex | read-only | current | Index definition for the pm124CtrllineLoopTerminal table |
| 1.3.6.1.4.1.20044.16.6.3.67.1.2 | Columnpm124CtrllineLoopTerminalPortn | read-write | current | Line Terminal Loopback :This OID operates a Line Terminal Loopback, looping line input signal on the line output port on the client side. The loop is located o… |
| 1.3.6.1.4.1.20044.16.7 | Nodepm124ri | |||
| 1.3.6.1.4.1.20044.16.7.1 | Nodepm124riTable | |||
| 1.3.6.1.4.1.20044.16.7.1.1 | Tablepm124RinvClientTable | not-accessible | current | List of the SFPs on the selected module |
| 1.3.6.1.4.1.20044.16.7.1.1.1 | Rowpm124RinvClientEntry | not-accessible | current | Row definition for the Client SFP table |
| 1.3.6.1.4.1.20044.16.7.1.1.1.1 | Columnpm124RinvClientIndex | read-only | current | Index for Client SFP table |
| 1.3.6.1.4.1.20044.16.7.1.1.1.2 | Columnpm124RinvSfpClient | read-only | current | Inventory for the SFP: This OID contains the inventory for the Client SFP |
| 1.3.6.1.4.1.20044.16.7.1.2 | Tablepm124RinvLineTable | not-accessible | current | List of the SFPs on the selected module |
| 1.3.6.1.4.1.20044.16.7.1.2.1 | Rowpm124RinvLineEntry | not-accessible | current | Row definition for the Line SFP table |
| 1.3.6.1.4.1.20044.16.7.1.2.1.1 | Columnpm124RinvLineIndex | read-only | current | Index for SFP table |
| 1.3.6.1.4.1.20044.16.7.1.2.1.2 | Columnpm124RinvsfpLine | read-only | current | Inventory for the SFP: This OID contains the inventory for the Line SFP |
| 1.3.6.1.4.1.20044.16.7.2 | Scalarpm124RinvReloadInventory | read-write | current | Reload the inventory: This OID triggers an inventory reload. |
| 1.3.6.1.4.1.20044.16.7.3 | Scalarpm124RinvHwPlatform | read-only | current | HW platform description: This OID contains the description of the Hardware platform. |
| 1.3.6.1.4.1.20044.16.7.4 | Scalarpm124RinvModulePlatform | read-only | current | Module platform description: This OID contains the description of the Module. |
| 1.3.6.1.4.1.20044.16.7.5 | Scalarpm124RinvSwPlatform | read-only | current | SW platform description: This OID contains the description of the Software platform. |
| 1.3.6.1.4.1.20044.16.7.6 | Scalarpm124RinvGwPlatform | read-only | current | GW platform desciption: This OID contains the description of the Gateware platform. |
| 1.3.6.1.4.1.20044.16.9 | Nodepm124Config | |||
| 1.3.6.1.4.1.20044.16.9.1 | Nodepm124CfgLsd | |||
| 1.3.6.1.4.1.20044.16.9.1.1 | Tablepm124CfgClientLsdTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.16.9.1.1.1 | Rowpm124CfgClientLsdEntry | not-accessible | current | Row definition for the lsd table |
| 1.3.6.1.4.1.20044.16.9.1.1.1.1 | Columnpm124CfgClientLsdIndex | read-only | current | Index definition for the clientLsd table |
| 1.3.6.1.4.1.20044.16.9.1.1.1.3 | Columnpm124CfgClientLsdModePortn | read-write | current | CAIS mode on Client Port :This register selects the way to activate the laser upon CAIS/CSF criteria detection on Port |
| 1.3.6.1.4.1.20044.16.9.1.1.1.4 | Columnpm124CfgClientAccessioCtrbInsPortn | read-write | current | CSF contributors on Client Port :This register selects the contributors to upstream CAIS/CSF on Port |
| 1.3.6.1.4.1.20044.16.9.1.1.1.5 | Columnpm124CfgClientAccCtrbInsPortn | read-write | current | CSF contributors on Client Port :This register selects the contributors to upstream CAIS/CSF on Port |
| 1.3.6.1.4.1.20044.16.9.1.1.1.6 | Columnpm124CfgLineAccessioCtrbInsPortn | read-write | current | CSF contributors on Client Port :This register selects the contributors to upstream CAIS/CSF on Port |
| 1.3.6.1.4.1.20044.16.9.1.1.1.8 | Columnpm124CfgClientAccCtrbActPortn | read-write | current | CAIS contributors on Client Port :This register selects the contributors to downstream CAIS/CSF on Port |
| 1.3.6.1.4.1.20044.16.9.1.1.1.9 | Columnpm124CfgLineAccessioCtrbActPortn | read-write | current | CAIS contributors on Client Port :This register selects the contributors to downstream CAIS/CSF on Port |
| 1.3.6.1.4.1.20044.16.9.2 | Nodepm124CfgStartUp | |||
| 1.3.6.1.4.1.20044.16.9.2.1 | Tablepm124CfgClientStartupTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.16.9.2.1.1 | Rowpm124CfgClientStartupEntry | not-accessible | current | Row definition for the startUp table |
| 1.3.6.1.4.1.20044.16.9.2.1.1.1 | Columnpm124CfgClientStartupIndex | read-only | current | Index definition for the clientStartup table |
| 1.3.6.1.4.1.20044.16.9.2.1.1.3 | Columnpm124CfgClientTrscvCtrlPortn | read-write | current | Default Settings on client TRSCV :This register configures the default initialisation settings on client transceiver. |
| 1.3.6.1.4.1.20044.16.9.2.1.1.5 | Columnpm124CfgClientOosModePortn | read-write | current | Default Settings on client TRSCV :This register configures the default initialisation settings on client transceiver. |
| 1.3.6.1.4.1.20044.16.9.2.2 | Nodepm124tablelineStartup | |||
| 1.3.6.1.4.1.20044.16.9.2.2.2 | Scalarpm124CfglineTrscvCtrl | read-write | current | Default Settings on line TRSCV :This register configures the default initialisation settings on line transceiver. |
| 1.3.6.1.4.1.20044.16.9.2.2.3 | Scalarpm124CfglineOosMode | read-write | current | Default Settings on line TRSCV :This register configures the default initialisation settings on line transceiver. |
| 1.3.6.1.4.1.20044.16.9.2.2.18 | Scalarpm124CfgmodProtSelect | read-write | current | Default Protocol on Module :This register configures the default initialisation protocol on the module. |
| 1.3.6.1.4.1.20044.16.9.3 | Nodepm124CfgLabels | |||
| 1.3.6.1.4.1.20044.16.9.3.1 | Tablepm124CfgLabelclientTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.16.9.3.1.1 | Rowpm124CfgLabelclientEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.16.9.3.1.1.1 | Columnpm124CfgLabelclientIndex | read-only | current | Index definition for the labelclient table |
| 1.3.6.1.4.1.20044.16.9.3.1.1.3 | Columnpm124CfgLabelclientPortn | read-write | current | Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. |
| 1.3.6.1.4.1.20044.16.9.3.2 | Tablepm124CfgLabellineTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.16.9.3.2.1 | Rowpm124CfgLabellineEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.16.9.3.2.1.1 | Columnpm124CfgLabellineIndex | read-only | current | Index definition for the labelline table |
| 1.3.6.1.4.1.20044.16.9.3.2.1.3 | Columnpm124CfgLabellinePortn | read-write | current | Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. |
| 1.3.6.1.4.1.20044.16.9.257 | Scalarpm124CfgWriteConfiguration | read-write | current | Write configuration to module:This OID writes the complete configuration to the module |
| 1.3.6.1.4.1.20044.16.10 | Nodepm124traps | |||
| 1.3.6.1.4.1.20044.16.10.2 | Scalarpm124trapPortNumber | read-only | current | Last port which generates a trap |
| 1.3.6.1.4.1.20044.16.10.3 | Scalarpm124trapLineNumber | read-only | current | Last Line which generates a trap |
| 1.3.6.1.4.1.20044.16.10.4 | Scalarpm124trapBoardNumber | read-only | current | Last module which generates a trap |
| 1.3.6.1.4.1.20044.16.10.30 | Notificationpm124LineTrapNotUrgentGoesOn | current | Not urgent Line default is activated | |
| 1.3.6.1.4.1.20044.16.10.31 | Notificationpm124LineTrapNotUrgentGoesOff | current | Not urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.16.10.32 | Notificationpm124LineTrapUrgentGoesOn | current | Urgent Line default is activated | |
| 1.3.6.1.4.1.20044.16.10.33 | Notificationpm124LineTrapUrgentGoesOff | current | Urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.16.10.34 | Notificationpm124LineTrapCritGoesOn | current | Critical Line default is activated | |
| 1.3.6.1.4.1.20044.16.10.35 | Notificationpm124LineTrapCritGoesOff | current | Critical Line default disappeared | |
| 1.3.6.1.4.1.20044.16.10.40 | Notificationpm124ClientTrapNotUrgentGoesOn | current | Not urgent client default is activated | |
| 1.3.6.1.4.1.20044.16.10.41 | Notificationpm124ClientTrapNotUrgentGoesOff | current | Not urgent client default disappeared | |
| 1.3.6.1.4.1.20044.16.10.42 | Notificationpm124ClientTrapUrgentGoesOn | current | Urgent client default is activated | |
| 1.3.6.1.4.1.20044.16.10.43 | Notificationpm124ClientTrapUrgentGoesOff | current | Urgent client default disappeared | |
| 1.3.6.1.4.1.20044.16.10.44 | Notificationpm124ClientTrapCritGoesOn | current | Critical client default is activated | |
| 1.3.6.1.4.1.20044.16.10.45 | Notificationpm124ClientTrapCritGoesOff | current | Critical client default disappeared | |
| 1.3.6.1.4.1.20044.16.10.50 | Notificationpm124PowerTrapUrgentGoesOn | current | Urgent power supply default is activated | |
| 1.3.6.1.4.1.20044.16.10.51 | Notificationpm124PowerTrapUrgentGoesOff | current | Urgent power supply default disappeared |