MIB Viewer

EKINOPS-Pm124-MIB

317 objects
MIB for the Ekinops Pm124 hardware.
OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.16IdentitymodulePm124MIB for the Ekinops Pm124 hardware.
1.3.6.1.4.1.20044.16.2Nodepm124alarms
1.3.6.1.4.1.20044.16.2.1Nodepm124AlmOther
1.3.6.1.4.1.20044.16.2.1.1Nodepm124AlmOtherNurg
1.3.6.1.4.1.20044.16.2.1.1.2Nodepm124AlmsynthAlm2
1.3.6.1.4.1.20044.16.2.1.1.2.1Scalarpm124AlmConfTableSaveread-onlycurrentPM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> other…
1.3.6.1.4.1.20044.16.2.1.1.2.2Scalarpm124AlmInvUploadread-onlycurrentInventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> other (1) <Alarmtype> other (1) <Polarit…
1.3.6.1.4.1.20044.16.2.1.1.2.3Scalarpm124AlmConfTableLoadread-onlycurrentPM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> other (1) <Alarmt…
1.3.6.1.4.1.20044.16.2.1.1.2.4Scalarpm124AlmCorrelatOffread-onlycurrentNot Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> other (1) <Alarmtype> other (1) <Pol…
1.3.6.1.4.1.20044.16.2.1.2Nodepm124AlmOtherUrg
1.3.6.1.4.1.20044.16.2.1.3Nodepm124AlmOtherCrit
1.3.6.1.4.1.20044.16.2.1.3.0Nodepm124AlmsynthAlm0
1.3.6.1.4.1.20044.16.2.1.3.0.9Scalarpm124AlmModuleGlobFailureread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the PM <Condtype> MODULE_GLOB_FAILURE <Probcause> equipmentMalfunction (16) <Alarmty…
1.3.6.1.4.1.20044.16.2.1.3.0.15Scalarpm124AlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.16.2.1.3.0.16Scalarpm124AlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.16.2.2Nodepm124AlmClient
1.3.6.1.4.1.20044.16.2.2.1Nodepm124AlmClientNurg
1.3.6.1.4.1.20044.16.2.2.1.32Tablepm124AlmclientSfpWarnDdmTablenot-accessiblecurrentList of pm124AlmclientSfpWarnDdm Article
1.3.6.1.4.1.20044.16.2.2.1.32.1Rowpm124AlmclientSfpWarnDdmEntrynot-accessiblecurrentRow definition for the pm124AlmclientSfpWarnDdm table
1.3.6.1.4.1.20044.16.2.2.1.32.1.1Columnpm124AlmclientSfpWarnDdmIndexread-onlycurrentIndex definition for the pm124AlmclientSfpWarnDdm table
1.3.6.1.4.1.20044.16.2.2.1.32.1.2Columnpm124AlmClientTxPwLowWngPortnread-onlycurrentClient SFP Tx Power Low Warning :Warning indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> CL…
1.3.6.1.4.1.20044.16.2.2.1.32.1.3Columnpm124AlmClientTxPwrHighWngPortnread-onlycurrentClient SFP Tx Power High Warning :Warning indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.16.2.2.1.32.1.4Columnpm124AlmClientTxBiasLowWngPortnread-onlycurrentClient SFP Bias Low Warning :Warning indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.16.2.2.1.32.1.5Columnpm124AlmClientTxBiasHighWngPortnread-onlycurrentClient SFP Bias High Warning :Warning indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.16.2.2.1.32.1.6Columnpm124AlmClientVccLowWngPortnread-onlycurrentClient SFP Power Supply Low Warning :Warning indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.16.2.2.1.32.1.7Columnpm124AlmClientVccHighWngPortnread-onlycurrentClient SFP Power Supply High Warning :Warning indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condty…
1.3.6.1.4.1.20044.16.2.2.1.32.1.8Columnpm124AlmClientTempLowWngPortnread-onlycurrentClient SFP Temp Low Warning :Warning indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_…
1.3.6.1.4.1.20044.16.2.2.1.32.1.9Columnpm124AlmClientTempHighWngPortnread-onlycurrentClient SFP Temp High Warning :Warning indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIEN…
1.3.6.1.4.1.20044.16.2.2.1.32.1.16Columnpm124AlmClientRxPwrLowWngPortnread-onlycurrentClient SFP Rx Power Low Warning :Warning indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLI…
1.3.6.1.4.1.20044.16.2.2.1.32.1.17Columnpm124AlmClientRxPwrHighWngPortnread-onlycurrentClient SFP Rx Power High Warning :Warning indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> C…
1.3.6.1.4.1.20044.16.2.2.2Nodepm124AlmClientUrg
1.3.6.1.4.1.20044.16.2.2.2.24Tablepm124AlmclientSfpAlmDdmTablenot-accessiblecurrentList of pm124AlmclientSfpAlmDdm Article
1.3.6.1.4.1.20044.16.2.2.2.24.1Rowpm124AlmclientSfpAlmDdmEntrynot-accessiblecurrentRow definition for the pm124AlmclientSfpAlmDdm table
1.3.6.1.4.1.20044.16.2.2.2.24.1.1Columnpm124AlmclientSfpAlmDdmIndexread-onlycurrentIndex definition for the pm124AlmclientSfpAlmDdm table
1.3.6.1.4.1.20044.16.2.2.2.24.1.2Columnpm124AlmClientTxPwrLowAlaPortnread-onlycurrentClient SFP Tx Power Low :Alarm indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_TX_PW…
1.3.6.1.4.1.20044.16.2.2.2.24.1.3Columnpm124AlmClientClientTxPwrHighAlaPortnread-onlycurrentClient SFP Tx Power High :Alarm indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIENT_CLI…
1.3.6.1.4.1.20044.16.2.2.2.24.1.4Columnpm124AlmClientTxBiasLowAlaPortnread-onlycurrentClient SFP Bias Low :Alarm indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_TX_…
1.3.6.1.4.1.20044.16.2.2.2.24.1.5Columnpm124AlmClientTxBiasHighAlaPortnread-onlycurrentClient SFP Bias High :Alarm indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIENT_T…
1.3.6.1.4.1.20044.16.2.2.2.24.1.6Columnpm124AlmClientVccLowAlaPortnread-onlycurrentClient SFP Power Supply Low :Alarm indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_V…
1.3.6.1.4.1.20044.16.2.2.2.24.1.7Columnpm124AlmClientVccHighAlaPortnread-onlycurrentClient SFP Power Supply High :Alarm indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIENT…
1.3.6.1.4.1.20044.16.2.2.2.24.1.8Columnpm124AlmClientTempLowAlaPortnread-onlycurrentClient SFP Temp Low :Alarm indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_TEMP_LOW_A…
1.3.6.1.4.1.20044.16.2.2.2.24.1.9Columnpm124AlmClientTempHighAlaPortnread-onlycurrentClient SFP Temp High :Alarm indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIENT_TEMP_HIG…
1.3.6.1.4.1.20044.16.2.2.2.24.1.16Columnpm124AlmClientRxPwrLowAlaPortnread-onlycurrentClient SFP Rx Power Low :Alarm indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_RX_PWR…
1.3.6.1.4.1.20044.16.2.2.2.24.1.17Columnpm124AlmClientRxPwrHighAlaPortnread-onlycurrentClient SFP Rx Power High :Alarm indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIENT_RX_P…
1.3.6.1.4.1.20044.16.2.2.3Nodepm124AlmClientCrit
1.3.6.1.4.1.20044.16.2.2.3.8Tablepm124AlmsynthAlmPortTablenot-accessiblecurrentList of pm124AlmsynthAlmPort Article
1.3.6.1.4.1.20044.16.2.2.3.8.1Rowpm124AlmsynthAlmPortEntrynot-accessiblecurrentRow definition for the pm124AlmsynthAlmPort table
1.3.6.1.4.1.20044.16.2.2.3.8.1.1Columnpm124AlmsynthAlmPortIndexread-onlycurrentIndex definition for the pm124AlmsynthAlmPort table
1.3.6.1.4.1.20044.16.2.2.3.8.1.2Columnpm124AlmClientSfpAbsentPortnread-onlycurrentClient SFP Absent :This OID indicates that the SFP module is not present in the client port. <Help> This alarm indicates if the client transceiver is present. …
1.3.6.1.4.1.20044.16.2.2.3.8.1.3Columnpm124AlmClientDdmAbsentPortnread-onlycurrentDDM Supported On Client SFP :This OID indicates that the Client SFP module does not support the Digital Diagnostic Monitoring function <Help> This status indic…
1.3.6.1.4.1.20044.16.2.2.3.8.1.5Columnpm124AlmClientHwFailAccPortnread-onlycurrentClient HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Condtype> CLIENT_HW_FAIL_ACC_1 <Probcause> equipmentMalfuncti…
1.3.6.1.4.1.20044.16.2.2.3.8.1.6Columnpm124AlmClientLsdPortnread-onlycurrentClient SFP Laser Shutdown :This OID indicates the Client SFP transmitter output has shut down. <Help> This status indicates if the client transceiver laser is …
1.3.6.1.4.1.20044.16.2.2.3.8.1.7Columnpm124AlmClientLocalOosPortnread-onlycurrentLocal Client Port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local c…
1.3.6.1.4.1.20044.16.2.2.3.8.1.8Columnpm124AlmClientRemoteOosPortnread-onlycurrentRemote Client Port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the remot…
1.3.6.1.4.1.20044.16.2.2.3.8.1.9Columnpm124AlmClientDwCaisPortnread-onlycurrentClient AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indicates if a Client Alarm Indication Signal is…
1.3.6.1.4.1.20044.16.2.2.3.8.1.10Columnpm124AlmClientSfpDdmWarningPortnread-onlycurrentWarning On Client SFP DDM :This OID indicates a warning is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Warning has been detecte…
1.3.6.1.4.1.20044.16.2.2.3.8.1.11Columnpm124AlmClientSfpDdmAlmPortnread-onlycurrentAlarm On Client SFP DDM :This OID indicates an alarm is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Alarm has been detected on …
1.3.6.1.4.1.20044.16.2.2.3.8.1.13Columnpm124AlmClientFailAccPortnread-onlycurrentClient Access Fail :This OID indicates a failure on the Client port <Condtype> CLIENT_FAIL_ACC_1 <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAla…
1.3.6.1.4.1.20044.16.2.2.3.8.1.17Columnpm124AlmClientUpCsfPortnread-onlycurrentClient Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu…
1.3.6.1.4.1.20044.16.2.2.3.16Tablepm124AlmclientAccessioAlmTablenot-accessiblecurrentList of pm124AlmclientAccessioAlm Article
1.3.6.1.4.1.20044.16.2.2.3.16.1Rowpm124AlmclientAccessioAlmEntrynot-accessiblecurrentRow definition for the pm124AlmclientAccessioAlm table
1.3.6.1.4.1.20044.16.2.2.3.16.1.1Columnpm124AlmclientAccessioAlmIndexread-onlycurrentIndex definition for the pm124AlmclientAccessioAlm table
1.3.6.1.4.1.20044.16.2.2.3.16.1.2Columnpm124AlmClientLasFailPortnread-onlycurrentClient SFP Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the client port (this alarm reports the transmitter failure alarm …
1.3.6.1.4.1.20044.16.2.2.3.16.1.5Columnpm124AlmClientLosPortnread-onlycurrentLoss Of Optical Signal On Client :This OID indicates that no signal is present on the SFP of the client port <Help> This alarm indicates if an optical signal i…
1.3.6.1.4.1.20044.16.2.2.3.40Tablepm124AlmclientAccAlmTablenot-accessiblecurrentList of pm124AlmclientAccAlm Article
1.3.6.1.4.1.20044.16.2.2.3.40.1Rowpm124AlmclientAccAlmEntrynot-accessiblecurrentRow definition for the pm124AlmclientAccAlm table
1.3.6.1.4.1.20044.16.2.2.3.40.1.1Columnpm124AlmclientAccAlmIndexread-onlycurrentIndex definition for the pm124AlmclientAccAlm table
1.3.6.1.4.1.20044.16.2.2.3.40.1.2Columnpm124AlmClientOosPortnread-onlycurrentClient Loss Of Frame :This OID indicates that a Loss of Frame has been detected on the client input signal <Help> This alarm indicates if there is a Loss of Fr…
1.3.6.1.4.1.20044.16.2.2.3.40.1.11Columnpm124AlmClientUpEsOvlPortnread-onlycurrentClient Upstream Buffer Overload :This OID indicates that the rate adaptation buffer for client port is in overload. <Help> This alarm indicates if there is a u…
1.3.6.1.4.1.20044.16.2.2.3.40.1.12Columnpm124AlmClientCsfDetPortnread-onlycurrentClient Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client…
1.3.6.1.4.1.20044.16.2.2.3.40.1.15Columnpm124AlmClientDwEsOvlPortnread-onlycurrentClient Downstream Buffer Overload :This OID indicates that the de-mapper buffer for client port is in overload. <Help> This alarm indicates if there is a downs…
1.3.6.1.4.1.20044.16.2.3Nodepm124AlmLine
1.3.6.1.4.1.20044.16.2.3.1Nodepm124AlmLineNurg
1.3.6.1.4.1.20044.16.2.3.1.66Tablepm124AlmlineSfpWarnDdmTablenot-accessiblecurrentList of pm124AlmlineSfpWarnDdm Article
1.3.6.1.4.1.20044.16.2.3.1.66.1Rowpm124AlmlineSfpWarnDdmEntrynot-accessiblecurrentRow definition for the pm124AlmlineSfpWarnDdm table
1.3.6.1.4.1.20044.16.2.3.1.66.1.1Columnpm124AlmlineSfpWarnDdmIndexread-onlycurrentIndex definition for the pm124AlmlineSfpWarnDdm table
1.3.6.1.4.1.20044.16.2.3.1.66.1.2Columnpm124AlmLineTxPwLowWngPortnread-onlycurrentLine SFP Tx Power Low Warning :Warning indicating that the SFP output power of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE…
1.3.6.1.4.1.20044.16.2.3.1.66.1.3Columnpm124AlmLineTxPwrHighWngPortnread-onlycurrentLine SFP Tx Power High Warning :Warning indicating that the SFP output power of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LI…
1.3.6.1.4.1.20044.16.2.3.1.66.1.4Columnpm124AlmLineTxBiasLowWngPortnread-onlycurrentLine SFP Bias Low Warning :Warning indicating that the SFP laser bias current of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LI…
1.3.6.1.4.1.20044.16.2.3.1.66.1.5Columnpm124AlmLineTxBiasHighWngPortnread-onlycurrentLine SFP Bias High Warning :Warning indicating that the SFP laser bias current of Line is higher than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.16.2.3.1.66.1.6Columnpm124AlmLineVccLowWngPortnread-onlycurrentLine SFP Power Supply Low Warning :Warning indicating that the SFP power supply of Line is lower than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.16.2.3.1.66.1.7Columnpm124AlmLineVccHighWngPortnread-onlycurrentLine SFP Power Supply High Warning :Warning indicating that the SFP power supply of Line is higher than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.16.2.3.1.66.1.8Columnpm124AlmLineTempLowWngPortnread-onlycurrentLine SFP Temp Low Warning :Warning indicating that the SFP temperature of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_TEMP…
1.3.6.1.4.1.20044.16.2.3.1.66.1.9Columnpm124AlmLineTempHighWngPortnread-onlycurrentLine SFP Temp High Warning :Warning indicating that the SFP temperature of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_TE…
1.3.6.1.4.1.20044.16.2.3.1.66.1.16Columnpm124AlmLineRxPwrLowWngPortnread-onlycurrentLine SFP Rx Power Low Warning :Warning indicating that the SFP input power of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_…
1.3.6.1.4.1.20044.16.2.3.1.66.1.17Columnpm124AlmLineRxPwrHighWngPortnread-onlycurrentLine SFP Rx Power High Warning :Warning indicating that the SFP input power of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LIN…
1.3.6.1.4.1.20044.16.2.3.2Nodepm124AlmLineUrg
1.3.6.1.4.1.20044.16.2.3.2.65Tablepm124AlmlineSfpAlmDdmTablenot-accessiblecurrentList of pm124AlmlineSfpAlmDdm Article
1.3.6.1.4.1.20044.16.2.3.2.65.1Rowpm124AlmlineSfpAlmDdmEntrynot-accessiblecurrentRow definition for the pm124AlmlineSfpAlmDdm table
1.3.6.1.4.1.20044.16.2.3.2.65.1.1Columnpm124AlmlineSfpAlmDdmIndexread-onlycurrentIndex definition for the pm124AlmlineSfpAlmDdm table
1.3.6.1.4.1.20044.16.2.3.2.65.1.2Columnpm124AlmLineTxPwrLowAlaPortnread-onlycurrentLine SFP Tx Power Low :Alarm indicating that the SFP output power of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_TX_PWR_LO…
1.3.6.1.4.1.20044.16.2.3.2.65.1.3Columnpm124AlmLineTxPwrHighAlaPortnread-onlycurrentLine SFP Tx Power High :Alarm indicating that the SFP output power of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_TX_PWR_…
1.3.6.1.4.1.20044.16.2.3.2.65.1.4Columnpm124AlmLineTxBiasLowAlaPortnread-onlycurrentLine SFP Bias Low :Alarm indicating that the SFP laser bias current of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_TX_BIAS…
1.3.6.1.4.1.20044.16.2.3.2.65.1.5Columnpm124AlmLineTxBiasHighAlaPortnread-onlycurrentLine SFP Bias High :Alarm indicating that the SFP laser bias current of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_TX_BI…
1.3.6.1.4.1.20044.16.2.3.2.65.1.6Columnpm124AlmLineVccLowAlaPortnread-onlycurrentLine SFP Power Supply Low :Alarm indicating that the SFP power supply of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_VCC_L…
1.3.6.1.4.1.20044.16.2.3.2.65.1.7Columnpm124AlmLineVccHighAlaPortnread-onlycurrentLine SFP Power Supply High :Alarm indicating that the SFP power supply of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_VCC…
1.3.6.1.4.1.20044.16.2.3.2.65.1.8Columnpm124AlmLineTempLowAlaPortnread-onlycurrentLine SFP Temp Low :Alarm indicating that the SFP temperature of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_TEMP_LOW_ALA <…
1.3.6.1.4.1.20044.16.2.3.2.65.1.9Columnpm124AlmLineTempHighAlaPortnread-onlycurrentLine SFP Temp High :Alarm indicating that the SFP temperature of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_TEMP_HIGH_AL…
1.3.6.1.4.1.20044.16.2.3.2.65.1.16Columnpm124AlmLineRxPwrLowAlaPortnread-onlycurrentLine SFP Rx Power Low :Alarm indicating that the SFP input power of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_RX_PWR_LOW…
1.3.6.1.4.1.20044.16.2.3.2.65.1.17Columnpm124AlmLineRxPwrHighAlaPortnread-onlycurrentLine SFP Rx Power High :Alarm indicating that the SFP input power of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_RX_PWR_H…
1.3.6.1.4.1.20044.16.2.3.3Nodepm124AlmLineCrit
1.3.6.1.4.1.20044.16.2.3.3.7Tablepm124AlmsynthAlmLineTablenot-accessiblecurrentList of pm124AlmsynthAlmLine Article
1.3.6.1.4.1.20044.16.2.3.3.7.1Rowpm124AlmsynthAlmLineEntrynot-accessiblecurrentRow definition for the pm124AlmsynthAlmLine table
1.3.6.1.4.1.20044.16.2.3.3.7.1.1Columnpm124AlmsynthAlmLineIndexread-onlycurrentIndex definition for the pm124AlmsynthAlmLine table
1.3.6.1.4.1.20044.16.2.3.3.7.1.2Columnpm124AlmLineSfpAbsentPortnread-onlycurrentLine SFP Absent :This OID indicates that the SFP module is not present in the line port. <Help> This alarm indicates if the line transceiver is present. <Condt…
1.3.6.1.4.1.20044.16.2.3.3.7.1.3Columnpm124AlmLineDdmAbsentPortnread-onlycurrentDDM Supported On Line SFP :This OID indicates that the SFP module on line port does not support Digital Diagnostic Monitoring Functions <Help> This status indi…
1.3.6.1.4.1.20044.16.2.3.3.7.1.5Columnpm124AlmLineHwFailPortnread-onlycurrentLine HW Fail :This OID indicates a failure condition on the Line port, the most probable cause being a HW issue <Condtype> LINE_HW_FAIL <Probcause> equipmentMa…
1.3.6.1.4.1.20044.16.2.3.3.7.1.6Columnpm124AlmLineLsdPortnread-onlycurrentLine SFP Laser Shutdown :This OID indicates the Client SFP transmitter output has shut down. <Help> This status indicates if the line transceiver laser is ON o…
1.3.6.1.4.1.20044.16.2.3.3.7.1.7Columnpm124AlmLineLocalOosPortnread-onlycurrentLine Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service…
1.3.6.1.4.1.20044.16.2.3.3.7.1.10Columnpm124AlmLineDdmWarningPortnread-onlycurrentWarning On Line SFP DDM :This OID indicates a warning is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Warning has been detected …
1.3.6.1.4.1.20044.16.2.3.3.7.1.11Columnpm124AlmLineDdmAlmPortnread-onlycurrentAlarm On Line SFP DDM :This OID indicates an alarm is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Alarm has been detected on th…
1.3.6.1.4.1.20044.16.2.3.3.7.1.13Columnpm124AlmLineFailPortnread-onlycurrentLine Fail :This OID indicates a failure on the Client port <Condtype> LINE_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12) <Polarity…
1.3.6.1.4.1.20044.16.2.3.3.64Tablepm124AlmlineAccessioAlmTablenot-accessiblecurrentList of pm124AlmlineAccessioAlm Article
1.3.6.1.4.1.20044.16.2.3.3.64.1Rowpm124AlmlineAccessioAlmEntrynot-accessiblecurrentRow definition for the pm124AlmlineAccessioAlm table
1.3.6.1.4.1.20044.16.2.3.3.64.1.1Columnpm124AlmlineAccessioAlmIndexread-onlycurrentIndex definition for the pm124AlmlineAccessioAlm table
1.3.6.1.4.1.20044.16.2.3.3.64.1.2Columnpm124AlmLineLasFailPortnread-onlycurrentLine SFP Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the line port (this alarm reports the transmitter failure alarm gene…
1.3.6.1.4.1.20044.16.2.3.3.64.1.5Columnpm124AlmLineLosPortnread-onlycurrentLoss Of Optical Signal On Line :This OID indicates that no signal is present on the SFP of the line port <Help> This alarm indicates if an optical signal is de…
1.3.6.1.4.1.20044.16.2.3.3.64.1.7Columnpm124AlmLineLossSyncPortnread-onlycurrentLine Loss Of 10b/8b Synchro :This OID indicates the upstream line input port has lost synchronization on its 10B/8B decoder <Help> This alarms indicates if the…
1.3.6.1.4.1.20044.16.3Nodepm124measures
1.3.6.1.4.1.20044.16.3.1Nodepm124MesrOther
1.3.6.1.4.1.20044.16.3.2Nodepm124MesrClient
1.3.6.1.4.1.20044.16.3.2.16Tablepm124MesrclientTemperatureTablenot-accessiblecurrentList of pm124MesrclientTemperature Article
1.3.6.1.4.1.20044.16.3.2.16.1Rowpm124MesrclientTemperatureEntrynot-accessiblecurrentRow definition for the pm124MesrclientTemperature table
1.3.6.1.4.1.20044.16.3.2.16.1.1Columnpm124MesrclientTemperatureIndexread-onlycurrentIndex definition for the pm124MesrclientTemperature table
1.3.6.1.4.1.20044.16.3.2.16.1.2Columnpm124MesrclientTemperaturePortnread-onlycurrentClient SFP Temperature :This OID gives the temperature value of the client SFP, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit …
1.3.6.1.4.1.20044.16.3.2.24Tablepm124MesrclientVoltTablenot-accessiblecurrentList of pm124MesrclientVolt Article
1.3.6.1.4.1.20044.16.3.2.24.1Rowpm124MesrclientVoltEntrynot-accessiblecurrentRow definition for the pm124MesrclientVolt table
1.3.6.1.4.1.20044.16.3.2.24.1.1Columnpm124MesrclientVoltIndexread-onlycurrentIndex definition for the pm124MesrclientVolt table
1.3.6.1.4.1.20044.16.3.2.24.1.2Columnpm124MesrclientVoltPortnread-onlycurrentClient SFP Power Supply :This OID gives the 3V3 voltage value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/100…
1.3.6.1.4.1.20044.16.3.2.32Tablepm124MesrclientTxBiasTablenot-accessiblecurrentList of pm124MesrclientTxBias Article
1.3.6.1.4.1.20044.16.3.2.32.1Rowpm124MesrclientTxBiasEntrynot-accessiblecurrentRow definition for the pm124MesrclientTxBias table
1.3.6.1.4.1.20044.16.3.2.32.1.1Columnpm124MesrclientTxBiasIndexread-onlycurrentIndex definition for the pm124MesrclientTxBias table
1.3.6.1.4.1.20044.16.3.2.32.1.2Columnpm124MesrclientTxBiasPortnread-onlycurrentClient SFP Laser Bias :This OID gives the bias value of the Client SFP, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <Help> Th…
1.3.6.1.4.1.20044.16.3.2.40Tablepm124MesrclientTxPowerTablenot-accessiblecurrentList of pm124MesrclientTxPower Article
1.3.6.1.4.1.20044.16.3.2.40.1Rowpm124MesrclientTxPowerEntrynot-accessiblecurrentRow definition for the pm124MesrclientTxPower table
1.3.6.1.4.1.20044.16.3.2.40.1.1Columnpm124MesrclientTxPowerIndexread-onlycurrentIndex definition for the pm124MesrclientTxPower table
1.3.6.1.4.1.20044.16.3.2.40.1.2Columnpm124MesrclientTxPowerPortnread-onlycurrentClient SFP Tx Power :This OID gives the transmit power value of the Client SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit…
1.3.6.1.4.1.20044.16.3.2.48Tablepm124MesrclientRxPowerTablenot-accessiblecurrentList of pm124MesrclientRxPower Article
1.3.6.1.4.1.20044.16.3.2.48.1Rowpm124MesrclientRxPowerEntrynot-accessiblecurrentRow definition for the pm124MesrclientRxPower table
1.3.6.1.4.1.20044.16.3.2.48.1.1Columnpm124MesrclientRxPowerIndexread-onlycurrentIndex definition for the pm124MesrclientRxPower table
1.3.6.1.4.1.20044.16.3.2.48.1.2Columnpm124MesrclientRxPowerPortnread-onlycurrentClient SFP Rx Power :This OID gives the receive power value of the Client SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = …
1.3.6.1.4.1.20044.16.3.3Nodepm124MesrLine
1.3.6.1.4.1.20044.16.3.3.64Tablepm124MesrlineTemperatureTablenot-accessiblecurrentList of pm124MesrlineTemperature Article
1.3.6.1.4.1.20044.16.3.3.64.1Rowpm124MesrlineTemperatureEntrynot-accessiblecurrentRow definition for the pm124MesrlineTemperature table
1.3.6.1.4.1.20044.16.3.3.64.1.1Columnpm124MesrlineTemperatureIndexread-onlycurrentIndex definition for the pm124MesrlineTemperature table
1.3.6.1.4.1.20044.16.3.3.64.1.2Columnpm124MesrlineTemperaturePortnread-onlycurrentLine SFP Temperature :This OID gives the temperature value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit = C)…
1.3.6.1.4.1.20044.16.3.3.65Tablepm124MesrlineVoltTablenot-accessiblecurrentList of pm124MesrlineVolt Article
1.3.6.1.4.1.20044.16.3.3.65.1Rowpm124MesrlineVoltEntrynot-accessiblecurrentRow definition for the pm124MesrlineVolt table
1.3.6.1.4.1.20044.16.3.3.65.1.1Columnpm124MesrlineVoltIndexread-onlycurrentIndex definition for the pm124MesrlineVolt table
1.3.6.1.4.1.20044.16.3.3.65.1.2Columnpm124MesrlineVoltPortnread-onlycurrentLine SFP Power Supply :This OID gives the 3V3 voltage value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/10000) (Unit = V) …
1.3.6.1.4.1.20044.16.3.3.66Tablepm124MesrlineTxBiasTablenot-accessiblecurrentList of pm124MesrlineTxBias Article
1.3.6.1.4.1.20044.16.3.3.66.1Rowpm124MesrlineTxBiasEntrynot-accessiblecurrentRow definition for the pm124MesrlineTxBias table
1.3.6.1.4.1.20044.16.3.3.66.1.1Columnpm124MesrlineTxBiasIndexread-onlycurrentIndex definition for the pm124MesrlineTxBias table
1.3.6.1.4.1.20044.16.3.3.66.1.2Columnpm124MesrlineTxBiasPortnread-onlycurrentLine SFP Laser Bias :This OID gives the bias value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <Help> This m…
1.3.6.1.4.1.20044.16.3.3.67Tablepm124MesrlineTxPowerTablenot-accessiblecurrentList of pm124MesrlineTxPower Article
1.3.6.1.4.1.20044.16.3.3.67.1Rowpm124MesrlineTxPowerEntrynot-accessiblecurrentRow definition for the pm124MesrlineTxPower table
1.3.6.1.4.1.20044.16.3.3.67.1.1Columnpm124MesrlineTxPowerIndexread-onlycurrentIndex definition for the pm124MesrlineTxPower table
1.3.6.1.4.1.20044.16.3.3.67.1.2Columnpm124MesrlineTxPowerPortnread-onlycurrentLine SFP Tx Power :This OID gives the transmit power value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = d…
1.3.6.1.4.1.20044.16.3.3.68Tablepm124MesrlineRxPowerTablenot-accessiblecurrentList of pm124MesrlineRxPower Article
1.3.6.1.4.1.20044.16.3.3.68.1Rowpm124MesrlineRxPowerEntrynot-accessiblecurrentRow definition for the pm124MesrlineRxPower table
1.3.6.1.4.1.20044.16.3.3.68.1.1Columnpm124MesrlineRxPowerIndexread-onlycurrentIndex definition for the pm124MesrlineRxPower table
1.3.6.1.4.1.20044.16.3.3.68.1.2Columnpm124MesrlineRxPowerPortnread-onlycurrentLine SFP Rx Power :This OID gives the receive power value of the Line SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm)…
1.3.6.1.4.1.20044.16.4Nodepm124counters
1.3.6.1.4.1.20044.16.4.1Nodepm124CntOther
1.3.6.1.4.1.20044.16.4.2Nodepm124CntClient
1.3.6.1.4.1.20044.16.4.2.16Tablepm124CntclientCbipErrCntTablenot-accessiblecurrentList of pm124CntclientCbipErrCnt Article
1.3.6.1.4.1.20044.16.4.2.16.1Rowpm124CntclientCbipErrCntEntrynot-accessiblecurrentRow definition for the pm124CntclientCbipErrCnt table
1.3.6.1.4.1.20044.16.4.2.16.1.1Columnpm124CntclientCbipErrCntIndexread-onlycurrentIndex definition for the pm124CntclientCbipErrCnt table
1.3.6.1.4.1.20044.16.4.2.16.1.2Columnpm124CntclientCbipErrCntValuePortnread-onlycurrentClient Output Errors (Err Sec) :This counter is incremented by one each time one or several CBIP parity error is detected during one second on the client outpu…
1.3.6.1.4.1.20044.16.4.2.16.1.3Columnpm124CntclientCbipErrCntErrorPortnread-onlycurrentClient CBIP counter error :This OID when set indicates the CBIP error counter value is invalid on Port
1.3.6.1.4.1.20044.16.4.2.16.1.4Columnpm124CntclientCbipErrCntOverloadPortnread-onlycurrentClient CBIP counter overload :This OID when set indicates a CBIP error counter overload on Port
1.3.6.1.4.1.20044.16.4.2.24Tablepm124CntclientB1ErrCntTablenot-accessiblecurrentList of pm124CntclientB1ErrCnt Article
1.3.6.1.4.1.20044.16.4.2.24.1Rowpm124CntclientB1ErrCntEntrynot-accessiblecurrentRow definition for the pm124CntclientB1ErrCnt table
1.3.6.1.4.1.20044.16.4.2.24.1.1Columnpm124CntclientB1ErrCntIndexread-onlycurrentIndex definition for the pm124CntclientB1ErrCnt table
1.3.6.1.4.1.20044.16.4.2.24.1.2Columnpm124CntclientB1ErrCntValuePortnread-onlycurrentClient Input Errors (Err Sec) :This counter is incremented by one each time one or several B1 error is detected during one second on the client input stream <H…
1.3.6.1.4.1.20044.16.4.2.24.1.3Columnpm124CntclientB1ErrCntErrorPortnread-onlycurrentClient B1 counter error :This OID when set indicates the B1 counter value is invalid on Port
1.3.6.1.4.1.20044.16.4.2.24.1.4Columnpm124CntclientB1ErrCntOverloadPortnread-onlycurrentClient B1 counter overload :This OID when set indicates a B1 counter overload on Port
1.3.6.1.4.1.20044.16.4.3Nodepm124CntLine
1.3.6.1.4.1.20044.16.4.3.64Tablepm124CntlineDispErrCntTablenot-accessiblecurrentList of pm124CntlineDispErrCnt Article
1.3.6.1.4.1.20044.16.4.3.64.1Rowpm124CntlineDispErrCntEntrynot-accessiblecurrentRow definition for the pm124CntlineDispErrCnt table
1.3.6.1.4.1.20044.16.4.3.64.1.1Columnpm124CntlineDispErrCntIndexread-onlycurrentIndex definition for the pm124CntlineDispErrCnt table
1.3.6.1.4.1.20044.16.4.3.64.1.2Columnpm124CntlineDispErrCntValuePortnread-onlycurrentLine RD errors (Err Sec) :This counter is in incremented by one each time one or several 10b/8b running disparity error is detected during one second on the Li…
1.3.6.1.4.1.20044.16.4.3.64.1.3Columnpm124CntlineDispErrCntErrorPortnread-onlycurrentLine counter error :This OID when set indicates the line error counter value is invalid on Line
1.3.6.1.4.1.20044.16.4.3.64.1.4Columnpm124CntlineDispErrCntOverloadPortnread-onlycurrentLine counter overload :This OID when set indicates a line input error counter overload on Line
1.3.6.1.4.1.20044.16.4.3.65Tablepm124CntlineCrcErrCntTablenot-accessiblecurrentList of pm124CntlineCrcErrCnt Article
1.3.6.1.4.1.20044.16.4.3.65.1Rowpm124CntlineCrcErrCntEntrynot-accessiblecurrentRow definition for the pm124CntlineCrcErrCnt table
1.3.6.1.4.1.20044.16.4.3.65.1.1Columnpm124CntlineCrcErrCntIndexread-onlycurrentIndex definition for the pm124CntlineCrcErrCnt table
1.3.6.1.4.1.20044.16.4.3.65.1.2Columnpm124CntlineCrcErrCntValuePortnread-onlycurrentLine Input Errors (Err Sec) :This counter is incremented by one each time one or several CRC error is detected during one second on the Line port <Help> This c…
1.3.6.1.4.1.20044.16.4.3.65.1.3Columnpm124CntlineCrcErrCntErrorPortnread-onlycurrentCRC Errors counter error :This OID when set indicates the CRC Errors counter value is invalid on line port
1.3.6.1.4.1.20044.16.4.3.65.1.4Columnpm124CntlineCrcErrCntOverloadPortnread-onlycurrentCRC Errors counter overload :This OID when set indicates a CRC Errors counter overload on line port
1.3.6.1.4.1.20044.16.4.259Scalarpm124CntCountersResetread-writecurrentCounters Reset:This OID resets and restarts all the counters
1.3.6.1.4.1.20044.16.4.260Scalarpm124CntCountersStopread-writecurrentCounters stop:This OID stops all the counters
1.3.6.1.4.1.20044.16.6Nodepm124controlsWrite
1.3.6.1.4.1.20044.16.6.1Nodepm124CtrlOther
1.3.6.1.4.1.20044.16.6.1.0Nodepm124Ctrlsynth0
1.3.6.1.4.1.20044.16.6.1.0.1Scalarpm124CtrlConfLoadread-writecurrentLoad Configuration Tables :When set this enables loading from flash configuration1 into the module.
1.3.6.1.4.1.20044.16.6.1.0.9Scalarpm124CtrlConfFlashread-writecurrentWrite Configuration Tables :This bit saves the current configuration of the module as configuration in the flash. <Help> This control saves the customer config…
1.3.6.1.4.1.20044.16.6.1.0.13Scalarpm124CtrlConfClearread-writecurrentClear Configuration Tables :This bit clears the configuration tables from configuration in the flash. <Help> This control restores the default configuration of…
1.3.6.1.4.1.20044.16.6.1.4Nodepm124Ctrlsynth4
1.3.6.1.4.1.20044.16.6.1.4.1Scalarpm124CtrlCorrelatOnread-writecurrentEnable Alarm Correlation :This OID enables the alarm correlation in the PM.
1.3.6.1.4.1.20044.16.6.1.4.2Scalarpm124CtrlCorrelatOffread-writecurrentDisable Alarm Correlation :This OID disables the alarm correlation in the PM.
1.3.6.1.4.1.20044.16.6.1.5Nodepm124CtrlswMgnt
1.3.6.1.4.1.20044.16.6.1.5.2Scalarpm124CtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the Software. This reset is traffic affecting, and the configuration of Software is reloaded on start…
1.3.6.1.4.1.20044.16.6.1.5.3Scalarpm124CtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the Software. This reset is not traffic affecting, and the configuration of the Sofwtare remains unch…
1.3.6.1.4.1.20044.16.6.1.41Scalarpm124Ctrlprotocolread-writecurrentClient Ports Protocol :This OID sets the protocol of the Client port <Help> This control defines the protocol of the client port (1xSTM4/OC12 or 4xSTM1/OC3)
1.3.6.1.4.1.20044.16.6.1.72Nodepm124CtrlledTest
1.3.6.1.4.1.20044.16.6.1.72.1Scalarpm124CtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.16.6.1.72.2Scalarpm124CtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.16.6.1.72.3Scalarpm124CtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.16.6.1.73Nodepm124CtrlmoduleOosMode
1.3.6.1.4.1.20044.16.6.1.73.1Scalarpm124CtrlModuleOosModeread-writecurrentPM Out Of Service :This OID sets the PM Out Of Service <Help> This control defines the service state of the complete module
1.3.6.1.4.1.20044.16.6.2Nodepm124CtrlClient
1.3.6.1.4.1.20044.16.6.2.16Tablepm124CtrlclientSfpOnoffTablenot-accessiblecurrentList of pm124CtrlclientSfpOnoff Article
1.3.6.1.4.1.20044.16.6.2.16.1Rowpm124CtrlclientSfpOnoffEntrynot-accessiblecurrentRow definition for the pm124CtrlclientSfpOnoff table
1.3.6.1.4.1.20044.16.6.2.16.1.1Columnpm124CtrlclientSfpOnoffIndexread-onlycurrentIndex definition for the pm124CtrlclientSfpOnoff table
1.3.6.1.4.1.20044.16.6.2.16.1.2Columnpm124CtrlclientSfpOnoffPortnread-writecurrentClient SFP Laser Shutdown :This OID switches off the clients SFP <Help> This control defines the laser state of the client transceiver
1.3.6.1.4.1.20044.16.6.2.17Tablepm124CtrlclientLoopTablenot-accessiblecurrentList of pm124CtrlclientLoop Article
1.3.6.1.4.1.20044.16.6.2.17.1Rowpm124CtrlclientLoopEntrynot-accessiblecurrentRow definition for the pm124CtrlclientLoop table
1.3.6.1.4.1.20044.16.6.2.17.1.1Columnpm124CtrlclientLoopIndexread-onlycurrentIndex definition for the pm124CtrlclientLoop table
1.3.6.1.4.1.20044.16.6.2.17.1.2Columnpm124CtrlclientLoopPortnread-writecurrentClient Facility Loopback :This OID operates a Client Facility Loopback, looping client input signal on the client output port. The loop is located on the clien…
1.3.6.1.4.1.20044.16.6.2.18Tablepm124CtrlclientCsfUpInsertTablenot-accessiblecurrentList of pm124CtrlclientCsfUpInsert Article
1.3.6.1.4.1.20044.16.6.2.18.1Rowpm124CtrlclientCsfUpInsertEntrynot-accessiblecurrentRow definition for the pm124CtrlclientCsfUpInsert table
1.3.6.1.4.1.20044.16.6.2.18.1.1Columnpm124CtrlclientCsfUpInsertIndexread-onlycurrentIndex definition for the pm124CtrlclientCsfUpInsert table
1.3.6.1.4.1.20044.16.6.2.18.1.2Columnpm124CtrlclientCsfUpInsertPortnread-writecurrentClient Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port.
1.3.6.1.4.1.20044.16.6.2.19Tablepm124CtrlclientCaisDwInsertTablenot-accessiblecurrentList of pm124CtrlclientCaisDwInsert Article
1.3.6.1.4.1.20044.16.6.2.19.1Rowpm124CtrlclientCaisDwInsertEntrynot-accessiblecurrentRow definition for the pm124CtrlclientCaisDwInsert table
1.3.6.1.4.1.20044.16.6.2.19.1.1Columnpm124CtrlclientCaisDwInsertIndexread-onlycurrentIndex definition for the pm124CtrlclientCaisDwInsert table
1.3.6.1.4.1.20044.16.6.2.19.1.2Columnpm124CtrlclientCaisDwInsertPortnread-writecurrentClient AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port.
1.3.6.1.4.1.20044.16.6.2.20Tablepm124CtrlclientOosModeTablenot-accessiblecurrentList of pm124CtrlclientOosMode Article
1.3.6.1.4.1.20044.16.6.2.20.1Rowpm124CtrlclientOosModeEntrynot-accessiblecurrentRow definition for the pm124CtrlclientOosMode table
1.3.6.1.4.1.20044.16.6.2.20.1.1Columnpm124CtrlclientOosModeIndexread-onlycurrentIndex definition for the pm124CtrlclientOosMode table
1.3.6.1.4.1.20044.16.6.2.20.1.2Columnpm124CtrlclientOosModePortnread-writecurrentClient Port Out Of Service :This OID sets the client port Out Of Service <Help> This controls defines the service state of the client port
1.3.6.1.4.1.20044.16.6.2.21Tablepm124CtrlclientAccessTermLoopTablenot-accessiblecurrentList of pm124CtrlclientAccessTermLoop Article
1.3.6.1.4.1.20044.16.6.2.21.1Rowpm124CtrlclientAccessTermLoopEntrynot-accessiblecurrentRow definition for the pm124CtrlclientAccessTermLoop table
1.3.6.1.4.1.20044.16.6.2.21.1.1Columnpm124CtrlclientAccessTermLoopIndexread-onlycurrentIndex definition for the pm124CtrlclientAccessTermLoop table
1.3.6.1.4.1.20044.16.6.2.21.1.2Columnpm124CtrlclientAccessTermLoopPortnread-writecurrentClient Terminal Loopback :This OID operates a Client Terminal Loopback, looping client input signal on the client output port. The loop is located on the line …
1.3.6.1.4.1.20044.16.6.3Nodepm124CtrlLine
1.3.6.1.4.1.20044.16.6.3.64Tablepm124CtrllineSfpOnoffTablenot-accessiblecurrentList of pm124CtrllineSfpOnoff Article
1.3.6.1.4.1.20044.16.6.3.64.1Rowpm124CtrllineSfpOnoffEntrynot-accessiblecurrentRow definition for the pm124CtrllineSfpOnoff table
1.3.6.1.4.1.20044.16.6.3.64.1.1Columnpm124CtrllineSfpOnoffIndexread-onlycurrentIndex definition for the pm124CtrllineSfpOnoff table
1.3.6.1.4.1.20044.16.6.3.64.1.2Columnpm124CtrllineSfpOnoffPortnread-writecurrentLine SFP Laser Shutdown :This OID switches off the line SFP <Help> This control defines the laser state of the line transceiver
1.3.6.1.4.1.20044.16.6.3.65Tablepm124CtrllineOosModeTablenot-accessiblecurrentList of pm124CtrllineOosMode Article
1.3.6.1.4.1.20044.16.6.3.65.1Rowpm124CtrllineOosModeEntrynot-accessiblecurrentRow definition for the pm124CtrllineOosMode table
1.3.6.1.4.1.20044.16.6.3.65.1.1Columnpm124CtrllineOosModeIndexread-onlycurrentIndex definition for the pm124CtrllineOosMode table
1.3.6.1.4.1.20044.16.6.3.65.1.2Columnpm124CtrllineOosModePortnread-writecurrentLine Port Out Of Service :This OID sets the line port Out Of Service <Help> This controls defines the service state of the line port
1.3.6.1.4.1.20044.16.6.3.66Tablepm124CtrllineLoopTablenot-accessiblecurrentList of pm124CtrllineLoop Article
1.3.6.1.4.1.20044.16.6.3.66.1Rowpm124CtrllineLoopEntrynot-accessiblecurrentRow definition for the pm124CtrllineLoop table
1.3.6.1.4.1.20044.16.6.3.66.1.1Columnpm124CtrllineLoopIndexread-onlycurrentIndex definition for the pm124CtrllineLoop table
1.3.6.1.4.1.20044.16.6.3.66.1.2Columnpm124CtrllineLoopPortnread-writecurrentLine Facility Loopback :This OID operates a Line Facility Loopback, looping line input signal on the line output port. The loop is located on the line transcei…
1.3.6.1.4.1.20044.16.6.3.67Tablepm124CtrllineLoopTerminalTablenot-accessiblecurrentList of pm124CtrllineLoopTerminal Article
1.3.6.1.4.1.20044.16.6.3.67.1Rowpm124CtrllineLoopTerminalEntrynot-accessiblecurrentRow definition for the pm124CtrllineLoopTerminal table
1.3.6.1.4.1.20044.16.6.3.67.1.1Columnpm124CtrllineLoopTerminalIndexread-onlycurrentIndex definition for the pm124CtrllineLoopTerminal table
1.3.6.1.4.1.20044.16.6.3.67.1.2Columnpm124CtrllineLoopTerminalPortnread-writecurrentLine Terminal Loopback :This OID operates a Line Terminal Loopback, looping line input signal on the line output port on the client side. The loop is located o…
1.3.6.1.4.1.20044.16.7Nodepm124ri
1.3.6.1.4.1.20044.16.7.1Nodepm124riTable
1.3.6.1.4.1.20044.16.7.1.1Tablepm124RinvClientTablenot-accessiblecurrentList of the SFPs on the selected module
1.3.6.1.4.1.20044.16.7.1.1.1Rowpm124RinvClientEntrynot-accessiblecurrentRow definition for the Client SFP table
1.3.6.1.4.1.20044.16.7.1.1.1.1Columnpm124RinvClientIndexread-onlycurrentIndex for Client SFP table
1.3.6.1.4.1.20044.16.7.1.1.1.2Columnpm124RinvSfpClientread-onlycurrentInventory for the SFP: This OID contains the inventory for the Client SFP
1.3.6.1.4.1.20044.16.7.1.2Tablepm124RinvLineTablenot-accessiblecurrentList of the SFPs on the selected module
1.3.6.1.4.1.20044.16.7.1.2.1Rowpm124RinvLineEntrynot-accessiblecurrentRow definition for the Line SFP table
1.3.6.1.4.1.20044.16.7.1.2.1.1Columnpm124RinvLineIndexread-onlycurrentIndex for SFP table
1.3.6.1.4.1.20044.16.7.1.2.1.2Columnpm124RinvsfpLineread-onlycurrentInventory for the SFP: This OID contains the inventory for the Line SFP
1.3.6.1.4.1.20044.16.7.2Scalarpm124RinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.16.7.3Scalarpm124RinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.16.7.4Scalarpm124RinvModulePlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.16.7.5Scalarpm124RinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.16.7.6Scalarpm124RinvGwPlatformread-onlycurrentGW platform desciption: This OID contains the description of the Gateware platform.
1.3.6.1.4.1.20044.16.9Nodepm124Config
1.3.6.1.4.1.20044.16.9.1Nodepm124CfgLsd
1.3.6.1.4.1.20044.16.9.1.1Tablepm124CfgClientLsdTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.16.9.1.1.1Rowpm124CfgClientLsdEntrynot-accessiblecurrentRow definition for the lsd table
1.3.6.1.4.1.20044.16.9.1.1.1.1Columnpm124CfgClientLsdIndexread-onlycurrentIndex definition for the clientLsd table
1.3.6.1.4.1.20044.16.9.1.1.1.3Columnpm124CfgClientLsdModePortnread-writecurrentCAIS mode on Client Port :This register selects the way to activate the laser upon CAIS/CSF criteria detection on Port
1.3.6.1.4.1.20044.16.9.1.1.1.4Columnpm124CfgClientAccessioCtrbInsPortnread-writecurrentCSF contributors on Client Port :This register selects the contributors to upstream CAIS/CSF on Port
1.3.6.1.4.1.20044.16.9.1.1.1.5Columnpm124CfgClientAccCtrbInsPortnread-writecurrentCSF contributors on Client Port :This register selects the contributors to upstream CAIS/CSF on Port
1.3.6.1.4.1.20044.16.9.1.1.1.6Columnpm124CfgLineAccessioCtrbInsPortnread-writecurrentCSF contributors on Client Port :This register selects the contributors to upstream CAIS/CSF on Port
1.3.6.1.4.1.20044.16.9.1.1.1.8Columnpm124CfgClientAccCtrbActPortnread-writecurrentCAIS contributors on Client Port :This register selects the contributors to downstream CAIS/CSF on Port
1.3.6.1.4.1.20044.16.9.1.1.1.9Columnpm124CfgLineAccessioCtrbActPortnread-writecurrentCAIS contributors on Client Port :This register selects the contributors to downstream CAIS/CSF on Port
1.3.6.1.4.1.20044.16.9.2Nodepm124CfgStartUp
1.3.6.1.4.1.20044.16.9.2.1Tablepm124CfgClientStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.16.9.2.1.1Rowpm124CfgClientStartupEntrynot-accessiblecurrentRow definition for the startUp table
1.3.6.1.4.1.20044.16.9.2.1.1.1Columnpm124CfgClientStartupIndexread-onlycurrentIndex definition for the clientStartup table
1.3.6.1.4.1.20044.16.9.2.1.1.3Columnpm124CfgClientTrscvCtrlPortnread-writecurrentDefault Settings on client TRSCV :This register configures the default initialisation settings on client transceiver.
1.3.6.1.4.1.20044.16.9.2.1.1.5Columnpm124CfgClientOosModePortnread-writecurrentDefault Settings on client TRSCV :This register configures the default initialisation settings on client transceiver.
1.3.6.1.4.1.20044.16.9.2.2Nodepm124tablelineStartup
1.3.6.1.4.1.20044.16.9.2.2.2Scalarpm124CfglineTrscvCtrlread-writecurrentDefault Settings on line TRSCV :This register configures the default initialisation settings on line transceiver.
1.3.6.1.4.1.20044.16.9.2.2.3Scalarpm124CfglineOosModeread-writecurrentDefault Settings on line TRSCV :This register configures the default initialisation settings on line transceiver.
1.3.6.1.4.1.20044.16.9.2.2.18Scalarpm124CfgmodProtSelectread-writecurrentDefault Protocol on Module :This register configures the default initialisation protocol on the module.
1.3.6.1.4.1.20044.16.9.3Nodepm124CfgLabels
1.3.6.1.4.1.20044.16.9.3.1Tablepm124CfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.16.9.3.1.1Rowpm124CfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.16.9.3.1.1.1Columnpm124CfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.16.9.3.1.1.3Columnpm124CfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.16.9.3.2Tablepm124CfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.16.9.3.2.1Rowpm124CfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.16.9.3.2.1.1Columnpm124CfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.16.9.3.2.1.3Columnpm124CfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.16.9.257Scalarpm124CfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.16.10Nodepm124traps
1.3.6.1.4.1.20044.16.10.2Scalarpm124trapPortNumberread-onlycurrentLast port which generates a trap
1.3.6.1.4.1.20044.16.10.3Scalarpm124trapLineNumberread-onlycurrentLast Line which generates a trap
1.3.6.1.4.1.20044.16.10.4Scalarpm124trapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.16.10.30Notificationpm124LineTrapNotUrgentGoesOncurrentNot urgent Line default is activated
1.3.6.1.4.1.20044.16.10.31Notificationpm124LineTrapNotUrgentGoesOffcurrentNot urgent Line default disappeared
1.3.6.1.4.1.20044.16.10.32Notificationpm124LineTrapUrgentGoesOncurrentUrgent Line default is activated
1.3.6.1.4.1.20044.16.10.33Notificationpm124LineTrapUrgentGoesOffcurrentUrgent Line default disappeared
1.3.6.1.4.1.20044.16.10.34Notificationpm124LineTrapCritGoesOncurrentCritical Line default is activated
1.3.6.1.4.1.20044.16.10.35Notificationpm124LineTrapCritGoesOffcurrentCritical Line default disappeared
1.3.6.1.4.1.20044.16.10.40Notificationpm124ClientTrapNotUrgentGoesOncurrentNot urgent client default is activated
1.3.6.1.4.1.20044.16.10.41Notificationpm124ClientTrapNotUrgentGoesOffcurrentNot urgent client default disappeared
1.3.6.1.4.1.20044.16.10.42Notificationpm124ClientTrapUrgentGoesOncurrentUrgent client default is activated
1.3.6.1.4.1.20044.16.10.43Notificationpm124ClientTrapUrgentGoesOffcurrentUrgent client default disappeared
1.3.6.1.4.1.20044.16.10.44Notificationpm124ClientTrapCritGoesOncurrentCritical client default is activated
1.3.6.1.4.1.20044.16.10.45Notificationpm124ClientTrapCritGoesOffcurrentCritical client default disappeared
1.3.6.1.4.1.20044.16.10.50Notificationpm124PowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.16.10.51Notificationpm124PowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared