MIB Viewer

EKINOPS-Pm1604-MIB

300 objects
MIB for the Pm1604 hardware.
OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.77IdentitymodulePm1604MIB for the Pm1604 hardware.
1.3.6.1.4.1.20044.77.2Nodepm1604alarms
1.3.6.1.4.1.20044.77.2.1Nodepm1604AlmOther
1.3.6.1.4.1.20044.77.2.1.1Nodepm1604AlmOtherNurg
1.3.6.1.4.1.20044.77.2.1.1.2Nodepm1604AlmsynthAlm2
1.3.6.1.4.1.20044.77.2.1.1.2.1Scalarpm1604AlmConfTableSaveread-onlycurrentPM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> other…
1.3.6.1.4.1.20044.77.2.1.1.2.2Scalarpm1604AlmInvUploadread-onlycurrentInventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> other (1) <Alarmtype> other (1) <Polarit…
1.3.6.1.4.1.20044.77.2.1.1.2.3Scalarpm1604AlmConfTableLoadread-onlycurrentPM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> other (1) <Alarmt…
1.3.6.1.4.1.20044.77.2.1.1.2.4Scalarpm1604AlmCorrelatOffread-onlycurrentNot Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> other (1) <Alarmtype> other (1) <Pol…
1.3.6.1.4.1.20044.77.2.1.2Nodepm1604AlmOtherUrg
1.3.6.1.4.1.20044.77.2.1.3Nodepm1604AlmOtherCrit
1.3.6.1.4.1.20044.77.2.1.3.0Nodepm1604AlmsynthAlm0
1.3.6.1.4.1.20044.77.2.1.3.0.9Scalarpm1604AlmModuleGlobFailureread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the PM <Condtype> MODULE_GLOB_FAILURE <Probcause> equipmentMalfunction (16) <Alarmty…
1.3.6.1.4.1.20044.77.2.1.3.0.15Scalarpm1604AlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.77.2.1.3.0.16Scalarpm1604AlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.77.2.2Nodepm1604AlmClient
1.3.6.1.4.1.20044.77.2.2.1Nodepm1604AlmClientNurg
1.3.6.1.4.1.20044.77.2.2.1.32Tablepm1604Almline1SfpWarnDdmTablenot-accessiblecurrentList of pm1604Almline1SfpWarnDdm Article
1.3.6.1.4.1.20044.77.2.2.1.32.1Rowpm1604Almline1SfpWarnDdmEntrynot-accessiblecurrentRow definition for the pm1604Almline1SfpWarnDdm table
1.3.6.1.4.1.20044.77.2.2.1.32.1.1Columnpm1604Almline1SfpWarnDdmIndexread-onlycurrentIndex definition for the pm1604Almline1SfpWarnDdm table
1.3.6.1.4.1.20044.77.2.2.1.32.1.2Columnpm1604AlmLine1TxPwLowWngPortnread-onlycurrentLine 1 SFP Tx Power Low Warning :Warning indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> LI…
1.3.6.1.4.1.20044.77.2.2.1.32.1.3Columnpm1604AlmLine1TxPwrHighWngPortnread-onlycurrentLine 1 SFP Tx Power High Warning :Warning indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.77.2.2.1.32.1.4Columnpm1604AlmLine1TxBiasLowWngPortnread-onlycurrentLine 1 SFP Bias Low Warning :Warning indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.77.2.2.1.32.1.5Columnpm1604AlmLine1TxBiasHighWngPortnread-onlycurrentLine 1 SFP Bias High Warning :Warning indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.77.2.2.1.32.1.6Columnpm1604AlmLine1VccLowWngPortnread-onlycurrentLine 1 SFP Power Supply Low Warning :Warning indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.77.2.2.1.32.1.7Columnpm1604AlmLine1VccHighWngPortnread-onlycurrentLine 1 SFP Power Supply High Warning :Warning indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condty…
1.3.6.1.4.1.20044.77.2.2.1.32.1.8Columnpm1604AlmLine1TempLowWngPortnread-onlycurrentLine 1 SFP Temp Low Warning :Warning indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE1_T…
1.3.6.1.4.1.20044.77.2.2.1.32.1.9Columnpm1604AlmLine1TempHighWngPortnread-onlycurrentLine 1 SFP Temp High Warning :Warning indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE1…
1.3.6.1.4.1.20044.77.2.2.1.32.1.16Columnpm1604AlmLine1RxPwrLowWngPortnread-onlycurrentLine 1 SFP Rx Power Low Warning :Warning indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> LIN…
1.3.6.1.4.1.20044.77.2.2.1.32.1.17Columnpm1604AlmLine1RxPwrHighWngPortnread-onlycurrentLine 1 SFP Rx Power High Warning :Warning indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> L…
1.3.6.1.4.1.20044.77.2.2.2Nodepm1604AlmClientUrg
1.3.6.1.4.1.20044.77.2.2.2.24Tablepm1604Almline1SfpAlmDdmTablenot-accessiblecurrentList of pm1604Almline1SfpAlmDdm Article
1.3.6.1.4.1.20044.77.2.2.2.24.1Rowpm1604Almline1SfpAlmDdmEntrynot-accessiblecurrentRow definition for the pm1604Almline1SfpAlmDdm table
1.3.6.1.4.1.20044.77.2.2.2.24.1.1Columnpm1604Almline1SfpAlmDdmIndexread-onlycurrentIndex definition for the pm1604Almline1SfpAlmDdm table
1.3.6.1.4.1.20044.77.2.2.2.24.1.2Columnpm1604AlmLine1TxPwrLowAlaPortnread-onlycurrentLine 1 SFP Tx Power Low :Alarm indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE1_TX_PWR…
1.3.6.1.4.1.20044.77.2.2.2.24.1.3Columnpm1604AlmLine1Line1TxPwrHighAlaPortnread-onlycurrentLine 1 SFP Tx Power High :Alarm indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE1_LINE…
1.3.6.1.4.1.20044.77.2.2.2.24.1.4Columnpm1604AlmLine1TxBiasLowAlaPortnread-onlycurrentLine 1 SFP Bias Low :Alarm indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE1_TX_B…
1.3.6.1.4.1.20044.77.2.2.2.24.1.5Columnpm1604AlmLine1TxBiasHighAlaPortnread-onlycurrentLine 1 SFP Bias High :Alarm indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE1_TX…
1.3.6.1.4.1.20044.77.2.2.2.24.1.6Columnpm1604AlmLine1VccLowAlaPortnread-onlycurrentLine 1 SFP Power Supply Low :Alarm indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE1_VC…
1.3.6.1.4.1.20044.77.2.2.2.24.1.7Columnpm1604AlmLine1VccHighAlaPortnread-onlycurrentLine 1 SFP Power Supply High :Alarm indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE1_…
1.3.6.1.4.1.20044.77.2.2.2.24.1.8Columnpm1604AlmLine1TempLowAlaPortnread-onlycurrentLine 1 SFP Temp Low :Alarm indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE1_TEMP_LOW_AL…
1.3.6.1.4.1.20044.77.2.2.2.24.1.9Columnpm1604AlmLine1TempHighAlaPortnread-onlycurrentLine 1 SFP Temp High :Alarm indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE1_TEMP_HIGH…
1.3.6.1.4.1.20044.77.2.2.2.24.1.16Columnpm1604AlmLine1RxPwrLowAlaPortnread-onlycurrentLine 1 SFP Rx Power Low :Alarm indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE1_RX_PWR_…
1.3.6.1.4.1.20044.77.2.2.2.24.1.17Columnpm1604AlmLine1RxPwrHighAlaPortnread-onlycurrentLine 1 SFP Rx Power High :Alarm indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE1_RX_PW…
1.3.6.1.4.1.20044.77.2.2.3Nodepm1604AlmClientCrit
1.3.6.1.4.1.20044.77.2.2.3.8Tablepm1604AlmsynthAlmLine1Tablenot-accessiblecurrentList of pm1604AlmsynthAlmLine1 Article
1.3.6.1.4.1.20044.77.2.2.3.8.1Rowpm1604AlmsynthAlmLine1Entrynot-accessiblecurrentRow definition for the pm1604AlmsynthAlmLine1 table
1.3.6.1.4.1.20044.77.2.2.3.8.1.1Columnpm1604AlmsynthAlmLine1Indexread-onlycurrentIndex definition for the pm1604AlmsynthAlmLine1 table
1.3.6.1.4.1.20044.77.2.2.3.8.1.2Columnpm1604AlmLine1SfpAbsentPortnread-onlycurrentLine 1 SFP Absent :This OID indicates that the SFP module is not present in the Line 1 port. <Help> This alarm indicates if the line 1 transceiver is present. …
1.3.6.1.4.1.20044.77.2.2.3.8.1.3Columnpm1604AlmLine1DdmAbsentPortnread-onlycurrentDDM Supported On Line 1 SFP :This OID indicates that the Line 1 SFP module does not support the Digital Diagnostic Monitoring function <Help> This status indic…
1.3.6.1.4.1.20044.77.2.2.3.8.1.5Columnpm1604AlmLine1HwFailAccPortnread-onlycurrentLine 1 HW Fail :This OID indicates a failure on Line 1 port, most probably caused by a HW issue. <Condtype> LINE1_HW_FAIL_ACC_A <Probcause> equipmentMalfunctio…
1.3.6.1.4.1.20044.77.2.2.3.8.1.6Columnpm1604AlmLine1LsdPortnread-onlycurrentLine 1 SFP Laser Shutdown :This OID indicates the Line 1 SFP transmitter output has shut down. <Help> This status indicates if the line 1 transceiver laser is …
1.3.6.1.4.1.20044.77.2.2.3.8.1.7Columnpm1604AlmLine1LocalOosPortnread-onlycurrentLine 1 Port In Service :This OID indicates that the local Line 1 port is In Service (1) or Out of Service (2) <Help> This status indicates if the line port 1 i…
1.3.6.1.4.1.20044.77.2.2.3.8.1.9Columnpm1604AlmLine1DwCaisPortnread-onlycurrentLine 1 AIS Inserted :This OID indicates a CAIS has been inserted on the output Line 1 port. <Help> This status indicates if a Line Alarm Indication Signal is c…
1.3.6.1.4.1.20044.77.2.2.3.8.1.10Columnpm1604AlmLine1SfpDdmWarningPortnread-onlycurrentWarning On Line 1 SFP DDM :This OID indicates a warning is being received from the Line 1 SFP DDM <Help> This alarm indicates if a DDM Warning has been detecte…
1.3.6.1.4.1.20044.77.2.2.3.8.1.11Columnpm1604AlmLine1SfpDdmAlmPortnread-onlycurrentAlarm On Line 1 SFP DDM :This OID indicates an alarm is being received from the Line 1 SFP DDM <Help> This alarm indicates if a DDM Alarm has been detected on …
1.3.6.1.4.1.20044.77.2.2.3.8.1.13Columnpm1604AlmLine1FailAccPortnread-onlycurrentLine 1 Access Fail :This OID indicates a failure on the Line 1 port <Condtype> LINE1_FAIL_ACC_A <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlar…
1.3.6.1.4.1.20044.77.2.2.3.16Tablepm1604Almline1AccessioAlmTablenot-accessiblecurrentList of pm1604Almline1AccessioAlm Article
1.3.6.1.4.1.20044.77.2.2.3.16.1Rowpm1604Almline1AccessioAlmEntrynot-accessiblecurrentRow definition for the pm1604Almline1AccessioAlm table
1.3.6.1.4.1.20044.77.2.2.3.16.1.1Columnpm1604Almline1AccessioAlmIndexread-onlycurrentIndex definition for the pm1604Almline1AccessioAlm table
1.3.6.1.4.1.20044.77.2.2.3.16.1.2Columnpm1604AlmLine1LasFailPortnread-onlycurrentLine 1 SFP Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the Line 1 port (this alarm reports the transmitter failure alarm …
1.3.6.1.4.1.20044.77.2.2.3.16.1.5Columnpm1604AlmLine1LosPortnread-onlycurrentLoss Of Optical Signal On Line 1 :This OID indicates that no signal is present on the SFP of the Line 1 port <Help> This alarm indicates if an optical signal i…
1.3.6.1.4.1.20044.77.2.2.3.16.1.7Columnpm1604AlmLine1LosCdrPortnread-onlycurrentLoss Of Signal On CDR On Line 1 : <Condtype> LINE1_LOS_CDR_A <Probcause> receiveFailure (41) <Alarmtype> equipmentAlarm (5) <Polarity> (2)
1.3.6.1.4.1.20044.77.2.2.3.16.1.8Columnpm1604AlmLine1ErrSigCdrPortnread-onlycurrentError Signal On CDR On Line 1 : <Condtype> LINE1__ERR_SIG_CDR_A <Probcause> receiveFailure (41) <Alarmtype> equipmentAlarm (5) <Polarity> (2)
1.3.6.1.4.1.20044.77.2.3Nodepm1604AlmLine
1.3.6.1.4.1.20044.77.2.3.1Nodepm1604AlmLineNurg
1.3.6.1.4.1.20044.77.2.3.1.36Tablepm1604Almline2SfpWarnDdmTablenot-accessiblecurrentList of pm1604Almline2SfpWarnDdm Article
1.3.6.1.4.1.20044.77.2.3.1.36.1Rowpm1604Almline2SfpWarnDdmEntrynot-accessiblecurrentRow definition for the pm1604Almline2SfpWarnDdm table
1.3.6.1.4.1.20044.77.2.3.1.36.1.1Columnpm1604Almline2SfpWarnDdmIndexread-onlycurrentIndex definition for the pm1604Almline2SfpWarnDdm table
1.3.6.1.4.1.20044.77.2.3.1.36.1.2Columnpm1604AlmLine2TxPwLowWngPortnread-onlycurrentLine 2 SFP Tx Power Low Warning :Warning indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> LI…
1.3.6.1.4.1.20044.77.2.3.1.36.1.3Columnpm1604AlmLine2TxPwrHighWngPortnread-onlycurrentLine 2 SFP Tx Power High Warning :Warning indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.77.2.3.1.36.1.4Columnpm1604AlmLine2TxBiasLowWngPortnread-onlycurrentLine 2 SFP Bias Low Warning :Warning indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.77.2.3.1.36.1.5Columnpm1604AlmLine2TxBiasHighWngPortnread-onlycurrentLine 2 SFP Bias High Warning :Warning indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.77.2.3.1.36.1.6Columnpm1604AlmLine2VccLowWngPortnread-onlycurrentLine 2 SFP Power Supply Low Warning :Warning indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.77.2.3.1.36.1.7Columnpm1604AlmLine2VccHighWngPortnread-onlycurrentLine 2 SFP Power Supply High Warning :Warning indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condty…
1.3.6.1.4.1.20044.77.2.3.1.36.1.8Columnpm1604AlmLine2TempLowWngPortnread-onlycurrentLine 2 SFP Temp Low Warning :Warning indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE2_T…
1.3.6.1.4.1.20044.77.2.3.1.36.1.9Columnpm1604AlmLine2TempHighWngPortnread-onlycurrentLine 2 SFP Temp High Warning :Warning indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE2…
1.3.6.1.4.1.20044.77.2.3.1.36.1.16Columnpm1604AlmLine2RxPwrLowWngPortnread-onlycurrentLine 2 SFP Rx Power Low Warning :Warning indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> LIN…
1.3.6.1.4.1.20044.77.2.3.1.36.1.17Columnpm1604AlmLine2RxPwrHighWngPortnread-onlycurrentLine 2 SFP Rx Power High Warning :Warning indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> L…
1.3.6.1.4.1.20044.77.2.3.2Nodepm1604AlmLineUrg
1.3.6.1.4.1.20044.77.2.3.2.28Tablepm1604Almline2SfpAlmDdmTablenot-accessiblecurrentList of pm1604Almline2SfpAlmDdm Article
1.3.6.1.4.1.20044.77.2.3.2.28.1Rowpm1604Almline2SfpAlmDdmEntrynot-accessiblecurrentRow definition for the pm1604Almline2SfpAlmDdm table
1.3.6.1.4.1.20044.77.2.3.2.28.1.1Columnpm1604Almline2SfpAlmDdmIndexread-onlycurrentIndex definition for the pm1604Almline2SfpAlmDdm table
1.3.6.1.4.1.20044.77.2.3.2.28.1.2Columnpm1604AlmLine2TxPwrLowAlaPortnread-onlycurrentLine 2 SFP Tx Power Low :Alarm indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE2_TX_PWR…
1.3.6.1.4.1.20044.77.2.3.2.28.1.3Columnpm1604AlmLine2Line2TxPwrHighAlaPortnread-onlycurrentLine 2 SFP Tx Power High :Alarm indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE2_LINE…
1.3.6.1.4.1.20044.77.2.3.2.28.1.4Columnpm1604AlmLine2TxBiasLowAlaPortnread-onlycurrentLine 2 SFP Bias Low :Alarm indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE2_TX_B…
1.3.6.1.4.1.20044.77.2.3.2.28.1.5Columnpm1604AlmLine2TxBiasHighAlaPortnread-onlycurrentLine 2 SFP Bias High :Alarm indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE2_TX…
1.3.6.1.4.1.20044.77.2.3.2.28.1.6Columnpm1604AlmLine2VccLowAlaPortnread-onlycurrentLine 2 SFP Power Supply Low :Alarm indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE2_VC…
1.3.6.1.4.1.20044.77.2.3.2.28.1.7Columnpm1604AlmLine2VccHighAlaPortnread-onlycurrentLine 2 SFP Power Supply High :Alarm indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE2_…
1.3.6.1.4.1.20044.77.2.3.2.28.1.8Columnpm1604AlmLine2TempLowAlaPortnread-onlycurrentLine 2 SFP Temp Low :Alarm indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE2_TEMP_LOW_AL…
1.3.6.1.4.1.20044.77.2.3.2.28.1.9Columnpm1604AlmLine2TempHighAlaPortnread-onlycurrentLine 2 SFP Temp High :Alarm indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE2_TEMP_HIGH…
1.3.6.1.4.1.20044.77.2.3.2.28.1.16Columnpm1604AlmLine2RxPwrLowAlaPortnread-onlycurrentLine 2 SFP Rx Power Low :Alarm indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE2_RX_PWR_…
1.3.6.1.4.1.20044.77.2.3.2.28.1.17Columnpm1604AlmLine2RxPwrHighAlaPortnread-onlycurrentLine 2 SFP Rx Power High :Alarm indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE2_RX_PW…
1.3.6.1.4.1.20044.77.2.3.3Nodepm1604AlmLineCrit
1.3.6.1.4.1.20044.77.2.3.3.12Tablepm1604AlmsynthAlmLine2Tablenot-accessiblecurrentList of pm1604AlmsynthAlmLine2 Article
1.3.6.1.4.1.20044.77.2.3.3.12.1Rowpm1604AlmsynthAlmLine2Entrynot-accessiblecurrentRow definition for the pm1604AlmsynthAlmLine2 table
1.3.6.1.4.1.20044.77.2.3.3.12.1.1Columnpm1604AlmsynthAlmLine2Indexread-onlycurrentIndex definition for the pm1604AlmsynthAlmLine2 table
1.3.6.1.4.1.20044.77.2.3.3.12.1.2Columnpm1604AlmLine2SfpAbsentPortnread-onlycurrentLine 2 SFP Absent :This OID indicates that the SFP module is not present in the Line 2 port. <Help> This alarm indicates if the line 2 transceiver is present. …
1.3.6.1.4.1.20044.77.2.3.3.12.1.3Columnpm1604AlmLine2DdmAbsentPortnread-onlycurrentDDM Supported On Line 2 SFP :This OID indicates that the Line 2 SFP module does not support the Digital Diagnostic Monitoring function <Help> This status indic…
1.3.6.1.4.1.20044.77.2.3.3.12.1.5Columnpm1604AlmLine2HwFailPortnread-onlycurrentLine 2 HW Fail :This OID indicates a failure on Line 2 port, most probably caused by a HW issue. <Condtype> LINE2_HW_FAIL_A <Probcause> equipmentMalfunction (1…
1.3.6.1.4.1.20044.77.2.3.3.12.1.6Columnpm1604AlmLine2LsdPortnread-onlycurrentLine 2 SFP Laser Shutdown :This OID indicates the Line 2 SFP transmitter output has shut down. <Help> This status indicates if the line 2 transceiver laser is …
1.3.6.1.4.1.20044.77.2.3.3.12.1.7Columnpm1604AlmLine2LocalOosPortnread-onlycurrentLine 2 Port In Service :This OID indicates that the local Line 2 port is In Service (1) or Out of Service (2) <Help> This status indicates if the line port 2 i…
1.3.6.1.4.1.20044.77.2.3.3.12.1.9Columnpm1604AlmLine2DwCaisPortnread-onlycurrentLine 2 AIS Inserted :This OID indicates a CAIS has been inserted on the output Line 2 port. <Help> This status indicates if a Line Alarm Indication Signal is c…
1.3.6.1.4.1.20044.77.2.3.3.12.1.10Columnpm1604AlmLine2DdmWarningPortnread-onlycurrentWarning On Line 2 SFP DDM :This OID indicates a warning is being received from the Line 2 SFP DDM <Help> This alarm indicates if a DDM Warning has been detecte…
1.3.6.1.4.1.20044.77.2.3.3.12.1.11Columnpm1604AlmLine2DdmAlmPortnread-onlycurrentAlarm On Line 2 SFP DDM :This OID indicates an alarm is being received from the Line 2 SFP DDM <Help> This alarm indicates if a DDM Alarm has been detected on …
1.3.6.1.4.1.20044.77.2.3.3.12.1.13Columnpm1604AlmLine2FailPortnread-onlycurrentLine 2 Access Fail :This OID indicates a failure on the Line 2 port <Condtype> LINE2_FAIL_A <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (1…
1.3.6.1.4.1.20044.77.2.3.3.20Tablepm1604Almline2AccessioAlmTablenot-accessiblecurrentList of pm1604Almline2AccessioAlm Article
1.3.6.1.4.1.20044.77.2.3.3.20.1Rowpm1604Almline2AccessioAlmEntrynot-accessiblecurrentRow definition for the pm1604Almline2AccessioAlm table
1.3.6.1.4.1.20044.77.2.3.3.20.1.1Columnpm1604Almline2AccessioAlmIndexread-onlycurrentIndex definition for the pm1604Almline2AccessioAlm table
1.3.6.1.4.1.20044.77.2.3.3.20.1.2Columnpm1604AlmLine2LasFailPortnread-onlycurrentLine 2 SFP Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the Line 2 port (this alarm reports the transmitter failure alarm …
1.3.6.1.4.1.20044.77.2.3.3.20.1.5Columnpm1604AlmLine2LosPortnread-onlycurrentLoss Of Optical Signal On Line 2 :This OID indicates that no signal is present on the SFP of the Line 2 port <Help> This alarm indicates if an optical signal i…
1.3.6.1.4.1.20044.77.2.3.3.20.1.7Columnpm1604AlmLine2LosCdrPortnread-onlycurrentLoss Of Signal On CDR On Line 2 : <Condtype> LINE2_LOS_CDR_A <Probcause> receiveFailure (41) <Alarmtype> equipmentAlarm (5) <Polarity> (2)
1.3.6.1.4.1.20044.77.2.3.3.20.1.8Columnpm1604AlmLine2ErrSigCdrPortnread-onlycurrentError Signal On CDR On Line 2 : <Condtype> LINE2__ERR_SIG_CDR_A <Probcause> receiveFailure (41) <Alarmtype> equipmentAlarm (5) <Polarity> (2)
1.3.6.1.4.1.20044.77.3Nodepm1604measures
1.3.6.1.4.1.20044.77.3.1Nodepm1604MesrOther
1.3.6.1.4.1.20044.77.3.2Nodepm1604MesrClient
1.3.6.1.4.1.20044.77.3.2.16Tablepm1604Mesrline1TemperatureTablenot-accessiblecurrentList of pm1604Mesrline1Temperature Article
1.3.6.1.4.1.20044.77.3.2.16.1Rowpm1604Mesrline1TemperatureEntrynot-accessiblecurrentRow definition for the pm1604Mesrline1Temperature table
1.3.6.1.4.1.20044.77.3.2.16.1.1Columnpm1604Mesrline1TemperatureIndexread-onlycurrentIndex definition for the pm1604Mesrline1Temperature table
1.3.6.1.4.1.20044.77.3.2.16.1.2Columnpm1604Mesrline1TemperaturePortnread-onlycurrentLine 1 SFP Temperature :This OID gives the temperature value of the SFP, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit = C) <H…
1.3.6.1.4.1.20044.77.3.2.24Tablepm1604Mesrline1VoltTablenot-accessiblecurrentList of pm1604Mesrline1Volt Article
1.3.6.1.4.1.20044.77.3.2.24.1Rowpm1604Mesrline1VoltEntrynot-accessiblecurrentRow definition for the pm1604Mesrline1Volt table
1.3.6.1.4.1.20044.77.3.2.24.1.1Columnpm1604Mesrline1VoltIndexread-onlycurrentIndex definition for the pm1604Mesrline1Volt table
1.3.6.1.4.1.20044.77.3.2.24.1.2Columnpm1604Mesrline1VoltPortnread-onlycurrentLine 1 SFP Power Supply :This OID gives the 3V3 voltage value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/100…
1.3.6.1.4.1.20044.77.3.2.32Tablepm1604Mesrline1TxBiasTablenot-accessiblecurrentList of pm1604Mesrline1TxBias Article
1.3.6.1.4.1.20044.77.3.2.32.1Rowpm1604Mesrline1TxBiasEntrynot-accessiblecurrentRow definition for the pm1604Mesrline1TxBias table
1.3.6.1.4.1.20044.77.3.2.32.1.1Columnpm1604Mesrline1TxBiasIndexread-onlycurrentIndex definition for the pm1604Mesrline1TxBias table
1.3.6.1.4.1.20044.77.3.2.32.1.2Columnpm1604Mesrline1TxBiasPortnread-onlycurrentLine 1 SFP Laser Bias :This OID gives the bias value of the SFP, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <Help> This meas…
1.3.6.1.4.1.20044.77.3.2.40Tablepm1604Mesrline1TxPowerTablenot-accessiblecurrentList of pm1604Mesrline1TxPower Article
1.3.6.1.4.1.20044.77.3.2.40.1Rowpm1604Mesrline1TxPowerEntrynot-accessiblecurrentRow definition for the pm1604Mesrline1TxPower table
1.3.6.1.4.1.20044.77.3.2.40.1.1Columnpm1604Mesrline1TxPowerIndexread-onlycurrentIndex definition for the pm1604Mesrline1TxPower table
1.3.6.1.4.1.20044.77.3.2.40.1.2Columnpm1604Mesrline1TxPowerPortnread-onlycurrentLine 1 SFP Tx Power :This OID gives the transmit power value of the SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm)…
1.3.6.1.4.1.20044.77.3.2.48Tablepm1604Mesrline1RxPowerTablenot-accessiblecurrentList of pm1604Mesrline1RxPower Article
1.3.6.1.4.1.20044.77.3.2.48.1Rowpm1604Mesrline1RxPowerEntrynot-accessiblecurrentRow definition for the pm1604Mesrline1RxPower table
1.3.6.1.4.1.20044.77.3.2.48.1.1Columnpm1604Mesrline1RxPowerIndexread-onlycurrentIndex definition for the pm1604Mesrline1RxPower table
1.3.6.1.4.1.20044.77.3.2.48.1.2Columnpm1604Mesrline1RxPowerPortnread-onlycurrentLine 1 SFP Rx Power :This OID gives the receive power value of the SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <H…
1.3.6.1.4.1.20044.77.3.3Nodepm1604MesrLine
1.3.6.1.4.1.20044.77.3.3.20Tablepm1604Mesrline2TemperatureTablenot-accessiblecurrentList of pm1604Mesrline2Temperature Article
1.3.6.1.4.1.20044.77.3.3.20.1Rowpm1604Mesrline2TemperatureEntrynot-accessiblecurrentRow definition for the pm1604Mesrline2Temperature table
1.3.6.1.4.1.20044.77.3.3.20.1.1Columnpm1604Mesrline2TemperatureIndexread-onlycurrentIndex definition for the pm1604Mesrline2Temperature table
1.3.6.1.4.1.20044.77.3.3.20.1.2Columnpm1604Mesrline2TemperaturePortnread-onlycurrentLine 2 SFP Temperature :This OID gives the temperature value of the SFP, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit = C) <H…
1.3.6.1.4.1.20044.77.3.3.28Tablepm1604Mesrline2VoltTablenot-accessiblecurrentList of pm1604Mesrline2Volt Article
1.3.6.1.4.1.20044.77.3.3.28.1Rowpm1604Mesrline2VoltEntrynot-accessiblecurrentRow definition for the pm1604Mesrline2Volt table
1.3.6.1.4.1.20044.77.3.3.28.1.1Columnpm1604Mesrline2VoltIndexread-onlycurrentIndex definition for the pm1604Mesrline2Volt table
1.3.6.1.4.1.20044.77.3.3.28.1.2Columnpm1604Mesrline2VoltPortnread-onlycurrentLine 2 SFP Power Supply :This OID gives the 3V3 voltage value of the SFP, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/10000) (Unit = V) <He…
1.3.6.1.4.1.20044.77.3.3.36Tablepm1604Mesrline2TxBiasTablenot-accessiblecurrentList of pm1604Mesrline2TxBias Article
1.3.6.1.4.1.20044.77.3.3.36.1Rowpm1604Mesrline2TxBiasEntrynot-accessiblecurrentRow definition for the pm1604Mesrline2TxBias table
1.3.6.1.4.1.20044.77.3.3.36.1.1Columnpm1604Mesrline2TxBiasIndexread-onlycurrentIndex definition for the pm1604Mesrline2TxBias table
1.3.6.1.4.1.20044.77.3.3.36.1.2Columnpm1604Mesrline2TxBiasPortnread-onlycurrentLine 2 SFP Laser Bias :This OID gives the bias value of the SFP, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <Help> This meas…
1.3.6.1.4.1.20044.77.3.3.44Tablepm1604Mesrline2TxPowerTablenot-accessiblecurrentList of pm1604Mesrline2TxPower Article
1.3.6.1.4.1.20044.77.3.3.44.1Rowpm1604Mesrline2TxPowerEntrynot-accessiblecurrentRow definition for the pm1604Mesrline2TxPower table
1.3.6.1.4.1.20044.77.3.3.44.1.1Columnpm1604Mesrline2TxPowerIndexread-onlycurrentIndex definition for the pm1604Mesrline2TxPower table
1.3.6.1.4.1.20044.77.3.3.44.1.2Columnpm1604Mesrline2TxPowerPortnread-onlycurrentLine 2 SFP Tx Power :This OID gives the transmit power value of the SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm)…
1.3.6.1.4.1.20044.77.3.3.52Tablepm1604Mesrline2RxPowerTablenot-accessiblecurrentList of pm1604Mesrline2RxPower Article
1.3.6.1.4.1.20044.77.3.3.52.1Rowpm1604Mesrline2RxPowerEntrynot-accessiblecurrentRow definition for the pm1604Mesrline2RxPower table
1.3.6.1.4.1.20044.77.3.3.52.1.1Columnpm1604Mesrline2RxPowerIndexread-onlycurrentIndex definition for the pm1604Mesrline2RxPower table
1.3.6.1.4.1.20044.77.3.3.52.1.2Columnpm1604Mesrline2RxPowerPortnread-onlycurrentLine 2 SFP Rx Power :This OID gives the receive power value of the SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <H…
1.3.6.1.4.1.20044.77.4Nodepm1604counters
1.3.6.1.4.1.20044.77.4.1Nodepm1604CntOther
1.3.6.1.4.1.20044.77.4.2Nodepm1604CntClient
1.3.6.1.4.1.20044.77.4.3Nodepm1604CntLine
1.3.6.1.4.1.20044.77.6Nodepm1604controlsWrite
1.3.6.1.4.1.20044.77.6.1Nodepm1604CtrlOther
1.3.6.1.4.1.20044.77.6.1.0Nodepm1604Ctrlsynth0
1.3.6.1.4.1.20044.77.6.1.0.1Scalarpm1604CtrlConfLoadread-writecurrentLoad Configuration Tables :When set this enables loading from flash configuration1 into the module.
1.3.6.1.4.1.20044.77.6.1.0.9Scalarpm1604CtrlConfFlashread-writecurrentWrite Configuration Tables :This bit saves the current configuration of the module as configuration in the flash. <Help> This control saves the customer config…
1.3.6.1.4.1.20044.77.6.1.0.13Scalarpm1604CtrlConfClearread-writecurrentClear Configuration Tables :This bit clears the configuration tables from configuration in the flash. <Help> This control restores the default configuration of…
1.3.6.1.4.1.20044.77.6.1.4Nodepm1604Ctrlsynth4
1.3.6.1.4.1.20044.77.6.1.4.1Scalarpm1604CtrlCorrelatOnread-writecurrentEnable Alarm Correlation :This OID enables the alarm correlation in the PM.
1.3.6.1.4.1.20044.77.6.1.4.2Scalarpm1604CtrlCorrelatOffread-writecurrentDisable Alarm Correlation :This OID disables the alarm correlation in the PM.
1.3.6.1.4.1.20044.77.6.1.5Nodepm1604CtrlswMgnt
1.3.6.1.4.1.20044.77.6.1.5.2Scalarpm1604CtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the Software. This reset is traffic affecting, and the configuration of Software is reloaded on start…
1.3.6.1.4.1.20044.77.6.1.5.3Scalarpm1604CtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the Software. This reset is not traffic affecting, and the configuration of the Sofwtare remains unch…
1.3.6.1.4.1.20044.77.6.1.72Nodepm1604CtrlledTest
1.3.6.1.4.1.20044.77.6.1.72.1Scalarpm1604CtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.77.6.1.72.2Scalarpm1604CtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.77.6.1.72.3Scalarpm1604CtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.77.6.1.73Nodepm1604CtrlmoduleOosMode
1.3.6.1.4.1.20044.77.6.1.73.1Scalarpm1604CtrlModuleOosModeread-writecurrentPM Out Of Service :This OID sets the PM Out Of Service <Help> This control defines the service state of the complete module
1.3.6.1.4.1.20044.77.6.2Nodepm1604CtrlClient
1.3.6.1.4.1.20044.77.6.2.16Tablepm1604Ctrlline1SfpOnoffTablenot-accessiblecurrentList of pm1604Ctrlline1SfpOnoff Article
1.3.6.1.4.1.20044.77.6.2.16.1Rowpm1604Ctrlline1SfpOnoffEntrynot-accessiblecurrentRow definition for the pm1604Ctrlline1SfpOnoff table
1.3.6.1.4.1.20044.77.6.2.16.1.1Columnpm1604Ctrlline1SfpOnoffIndexread-onlycurrentIndex definition for the pm1604Ctrlline1SfpOnoff table
1.3.6.1.4.1.20044.77.6.2.16.1.2Columnpm1604Ctrlline1SfpOnoffPortnread-writecurrentLine 1 SFP Laser Shutdown :This OID switches off the SFP <Help> This control defines the laser state of the line 1 transceiver
1.3.6.1.4.1.20044.77.6.2.17Tablepm1604Ctrlline1LoopbackTablenot-accessiblecurrentList of pm1604Ctrlline1Loopback Article
1.3.6.1.4.1.20044.77.6.2.17.1Rowpm1604Ctrlline1LoopbackEntrynot-accessiblecurrentRow definition for the pm1604Ctrlline1Loopback table
1.3.6.1.4.1.20044.77.6.2.17.1.1Columnpm1604Ctrlline1LoopbackIndexread-onlycurrentIndex definition for the pm1604Ctrlline1Loopback table
1.3.6.1.4.1.20044.77.6.2.17.1.2Columnpm1604Ctrlline1LoopbackPortnread-writecurrentLine 1 Facility Loopback :This OID operates a Client Facility Loopback, looping client input signal on the client output port. The loop is located on the clien…
1.3.6.1.4.1.20044.77.6.2.18Tablepm1604Ctrlline1LoopbackTermTablenot-accessiblecurrentList of pm1604Ctrlline1LoopbackTerm Article
1.3.6.1.4.1.20044.77.6.2.18.1Rowpm1604Ctrlline1LoopbackTermEntrynot-accessiblecurrentRow definition for the pm1604Ctrlline1LoopbackTerm table
1.3.6.1.4.1.20044.77.6.2.18.1.1Columnpm1604Ctrlline1LoopbackTermIndexread-onlycurrentIndex definition for the pm1604Ctrlline1LoopbackTerm table
1.3.6.1.4.1.20044.77.6.2.18.1.2Columnpm1604Ctrlline1LoopbackTermPortnread-writecurrentLine 1 Terminal Loopback :This OID operates a Client Terminal Loopback, looping client input signal on the client output port. The loop is located on the line …
1.3.6.1.4.1.20044.77.6.2.20Tablepm1604Ctrlline1OosModeTablenot-accessiblecurrentList of pm1604Ctrlline1OosMode Article
1.3.6.1.4.1.20044.77.6.2.20.1Rowpm1604Ctrlline1OosModeEntrynot-accessiblecurrentRow definition for the pm1604Ctrlline1OosMode table
1.3.6.1.4.1.20044.77.6.2.20.1.1Columnpm1604Ctrlline1OosModeIndexread-onlycurrentIndex definition for the pm1604Ctrlline1OosMode table
1.3.6.1.4.1.20044.77.6.2.20.1.2Columnpm1604Ctrlline1OosModePortnread-writecurrentLine 1 Port Out Of Service :This OID sets the port Out Of Service <Help> This controls defines the service state of the line 1 port
1.3.6.1.4.1.20044.77.6.2.48Tablepm1604CtrlprotocolTablenot-accessiblecurrentList of pm1604Ctrlprotocol Article
1.3.6.1.4.1.20044.77.6.2.48.1Rowpm1604CtrlprotocolEntrynot-accessiblecurrentRow definition for the pm1604Ctrlprotocol table
1.3.6.1.4.1.20044.77.6.2.48.1.1Columnpm1604CtrlprotocolIndexread-onlycurrentIndex definition for the pm1604Ctrlprotocol table
1.3.6.1.4.1.20044.77.6.2.48.1.2Columnpm1604CtrlprotocolPortnread-writecurrentLines Bitrate: This OID sets the protocol of the lines port.
1.3.6.1.4.1.20044.77.6.3Nodepm1604CtrlLine
1.3.6.1.4.1.20044.77.6.3.64Tablepm1604Ctrlline2SfpOnoffTablenot-accessiblecurrentList of pm1604Ctrlline2SfpOnoff Article
1.3.6.1.4.1.20044.77.6.3.64.1Rowpm1604Ctrlline2SfpOnoffEntrynot-accessiblecurrentRow definition for the pm1604Ctrlline2SfpOnoff table
1.3.6.1.4.1.20044.77.6.3.64.1.1Columnpm1604Ctrlline2SfpOnoffIndexread-onlycurrentIndex definition for the pm1604Ctrlline2SfpOnoff table
1.3.6.1.4.1.20044.77.6.3.64.1.2Columnpm1604Ctrlline2SfpOnoffPortnread-writecurrentLine 2 SFP Laser Shutdown :This OID switches off the SFP <Help> This control defines the laser state of the line 2 transceiver
1.3.6.1.4.1.20044.77.6.3.65Tablepm1604Ctrlline2OosModeTablenot-accessiblecurrentList of pm1604Ctrlline2OosMode Article
1.3.6.1.4.1.20044.77.6.3.65.1Rowpm1604Ctrlline2OosModeEntrynot-accessiblecurrentRow definition for the pm1604Ctrlline2OosMode table
1.3.6.1.4.1.20044.77.6.3.65.1.1Columnpm1604Ctrlline2OosModeIndexread-onlycurrentIndex definition for the pm1604Ctrlline2OosMode table
1.3.6.1.4.1.20044.77.6.3.65.1.2Columnpm1604Ctrlline2OosModePortnread-writecurrentLine 2 Port Out Of Service :This OID sets the port Out Of Service <Help> This controls defines the service state of the line 2 port
1.3.6.1.4.1.20044.77.6.3.66Tablepm1604Ctrlline2LoopbackTablenot-accessiblecurrentList of pm1604Ctrlline2Loopback Article
1.3.6.1.4.1.20044.77.6.3.66.1Rowpm1604Ctrlline2LoopbackEntrynot-accessiblecurrentRow definition for the pm1604Ctrlline2Loopback table
1.3.6.1.4.1.20044.77.6.3.66.1.1Columnpm1604Ctrlline2LoopbackIndexread-onlycurrentIndex definition for the pm1604Ctrlline2Loopback table
1.3.6.1.4.1.20044.77.6.3.66.1.2Columnpm1604Ctrlline2LoopbackPortnread-writecurrentLine 2 Facility Loopback :This OID operates a Line Facility Loopback, looping line input signal on the line output port. The loop is located on the line transc…
1.3.6.1.4.1.20044.77.6.3.67Tablepm1604Ctrlline2LoopbackTermTablenot-accessiblecurrentList of pm1604Ctrlline2LoopbackTerm Article
1.3.6.1.4.1.20044.77.6.3.67.1Rowpm1604Ctrlline2LoopbackTermEntrynot-accessiblecurrentRow definition for the pm1604Ctrlline2LoopbackTerm table
1.3.6.1.4.1.20044.77.6.3.67.1.1Columnpm1604Ctrlline2LoopbackTermIndexread-onlycurrentIndex definition for the pm1604Ctrlline2LoopbackTerm table
1.3.6.1.4.1.20044.77.6.3.67.1.2Columnpm1604Ctrlline2LoopbackTermPortnread-writecurrentLine 2 Terminal Loopback :This OID operates a Line Terminal Loopback, looping line input signal on the line output port. The loop is located on all client tran…
1.3.6.1.4.1.20044.77.7Nodepm1604ri
1.3.6.1.4.1.20044.77.7.1Nodepm1604riTable
1.3.6.1.4.1.20044.77.7.1.1Tablepm1604RinvLine1Tablenot-accessiblecurrentList of the SFPs on the selected module
1.3.6.1.4.1.20044.77.7.1.1.1Rowpm1604RinvLine1Entrynot-accessiblecurrentRow definition for the Line1 SFP table
1.3.6.1.4.1.20044.77.7.1.1.1.1Columnpm1604RinvLine1Indexread-onlycurrentIndex for Line1 SFP table
1.3.6.1.4.1.20044.77.7.1.1.1.2Columnpm1604RinvSfpLine1read-onlycurrentInventory for the SFP: This OID contains the inventory for the Line1 SFP
1.3.6.1.4.1.20044.77.7.1.2Tablepm1604RinvLine2Tablenot-accessiblecurrentList of the SFPs on the selected module
1.3.6.1.4.1.20044.77.7.1.2.1Rowpm1604RinvLine2Entrynot-accessiblecurrentRow definition for the Line SFP table
1.3.6.1.4.1.20044.77.7.1.2.1.1Columnpm1604RinvLine2Indexread-onlycurrentIndex for SFP table
1.3.6.1.4.1.20044.77.7.1.2.1.2Columnpm1604RinvsfpLine2read-onlycurrentInventory for the SFP: This OID contains the inventory for the Line2 SFP
1.3.6.1.4.1.20044.77.7.2Scalarpm1604RinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.77.7.3Scalarpm1604RinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.77.7.4Scalarpm1604RinvModulePlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.77.7.5Scalarpm1604RinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.77.7.6Scalarpm1604RinvGwPlatformread-onlycurrentGW platform desciption: This OID contains the description of the Gateware platform.
1.3.6.1.4.1.20044.77.9Nodepm1604Config
1.3.6.1.4.1.20044.77.9.1Nodepm1604CfgLsd
1.3.6.1.4.1.20044.77.9.1.1Tablepm1604CfgLine1LsdTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.77.9.1.1.1Rowpm1604CfgLine1LsdEntrynot-accessiblecurrentRow definition for the lsd table
1.3.6.1.4.1.20044.77.9.1.1.1.1Columnpm1604CfgLine1LsdIndexread-onlycurrentIndex definition for the line1Lsd table
1.3.6.1.4.1.20044.77.9.1.1.1.3Columnpm1604CfgLine1LsdModePortnread-writecurrentCAIS mode on Lines Port :This register selects the way to activate the laser upon CAIS/CSF criteria detection on Port
1.3.6.1.4.1.20044.77.9.1.1.1.4Columnpm1604CfgLine1AccessioCtrbInsPortnread-writecurrentCAIS contributors on Line 1 Port :This register selects the contributors to upstream CAIS/CSF on Port
1.3.6.1.4.1.20044.77.9.1.1.1.7Columnpm1604CfgLine2AccessioCtrbInsPortnread-writecurrentCAIS contributors on Lne 2 Port :This register selects the contributors to downstream CAIS/CSF on Port
1.3.6.1.4.1.20044.77.9.2Nodepm1604CfgStartUp
1.3.6.1.4.1.20044.77.9.2.1Tablepm1604CfgLine1StartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.77.9.2.1.1Rowpm1604CfgLine1StartupEntrynot-accessiblecurrentRow definition for the startUp table
1.3.6.1.4.1.20044.77.9.2.1.1.1Columnpm1604CfgLine1StartupIndexread-onlycurrentIndex definition for the line1Startup table
1.3.6.1.4.1.20044.77.9.2.1.1.3Columnpm1604CfgLine1TrscvCtrlPortnread-writecurrentDefault Settings on Line 1 TRSCV :This register configures the default initialisation settings on client transceiver.
1.3.6.1.4.1.20044.77.9.2.1.1.4Columnpm1604CfgLine1ProtocolPortnread-writecurrentDefault Protocol on Line 1 :This register configures the default initialisation protocol on the port.
1.3.6.1.4.1.20044.77.9.2.1.1.5Columnpm1604CfgLine1OosModePortnread-writecurrentDefault Settings on Line 1 TRSCV :This register configures the default initialisation settings on client transceiver.
1.3.6.1.4.1.20044.77.9.2.2Tablepm1604CfgLine2StartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.77.9.2.2.1Rowpm1604CfgLine2StartupEntrynot-accessiblecurrentRow definition for the startUp table
1.3.6.1.4.1.20044.77.9.2.2.1.1Columnpm1604CfgLine2StartupIndexread-onlycurrentIndex definition for the line2Startup table
1.3.6.1.4.1.20044.77.9.2.2.1.3Columnpm1604CfgLine2TrscvCtrlPortnread-writecurrentDefault Settings on Line 2 TRSCV :This register configures the default initialisation settings on line transceiver.
1.3.6.1.4.1.20044.77.9.2.2.1.4Columnpm1604CfgLine2OosModePortnread-writecurrentDefault Settings on Line 2 TRSCV :This register configures the default initialisation settings on line transceiver.
1.3.6.1.4.1.20044.77.9.2.3Tablepm1604CfgOtxtlhTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.77.9.2.3.1Rowpm1604CfgOtxtlhEntrynot-accessiblecurrentRow definition for the startUp table
1.3.6.1.4.1.20044.77.9.2.3.1.1Columnpm1604CfgOtxtlhIndexread-onlycurrentIndex definition for the otxtlh table
1.3.6.1.4.1.20044.77.9.2.3.1.3Columnpm1604CfgLineControlsPortnread-writedeprecatedDefault Line settings :This register configures the start-up settings on the ports
1.3.6.1.4.1.20044.77.9.2.3.1.6Columnpm1604CfgLinePwrLaserPortnread-writecurrentDefault Line output Power :This register configures the start-up output power of the client transceiver (Unit = dBm)
1.3.6.1.4.1.20044.77.9.2.3.1.7Columnpm1604CfgLineFCurrentPortnread-writecurrentDefault Line transceiver Channel :This register configures the start-up laser channel of the client transceiver
1.3.6.1.4.1.20044.77.9.2.3.1.8Columnpm1604CfgLineGridCurrentPortnread-writecurrentDefault Line transceiver Grid :This register configures the start-up laser grid of the client transceiver
1.3.6.1.4.1.20044.77.9.2.3.1.9Columnpm1604CfgLineFoPortnread-writecurrentDefault Line first Frequency :This register configures the start-up first frequency of the client transceiver
1.3.6.1.4.1.20044.77.9.3Nodepm1604CfgLabels
1.3.6.1.4.1.20044.77.9.3.1Tablepm1604CfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.77.9.3.1.1Rowpm1604CfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.77.9.3.1.1.1Columnpm1604CfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.77.9.3.1.1.3Columnpm1604CfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.77.9.3.2Tablepm1604CfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.77.9.3.2.1Rowpm1604CfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.77.9.3.2.1.1Columnpm1604CfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.77.9.3.2.1.3Columnpm1604CfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.77.9.4Nodepm1604CfgStartuptablefive
1.3.6.1.4.1.20044.77.9.4.1Tablepm1604CfgOtxtlhcapabilitiesTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.77.9.4.1.1Rowpm1604CfgOtxtlhcapabilitiesEntrynot-accessiblecurrentRow definition for the startuptablefive table
1.3.6.1.4.1.20044.77.9.4.1.1.1Columnpm1604CfgOtxtlhcapabilitiesIndexread-onlycurrentIndex definition for the otxtlhcapabilities table
1.3.6.1.4.1.20044.77.9.4.1.1.3Columnpm1604CfgComponentTypePortnread-writecurrentComponent parameters :This OID defines the component parameters
1.3.6.1.4.1.20044.77.9.4.1.1.4Columnpm1604CfgMiscellaneousPortnread-writecurrentMiscellaneous default settings :This OID defines the miscellaneous parameters
1.3.6.1.4.1.20044.77.9.4.1.1.5Columnpm1604CfgFirstChannelPortnread-writecurrentNumber of the first channel of the component :This OID defines the first channel number of the PM
1.3.6.1.4.1.20044.77.9.4.1.1.6Columnpm1604CfgLastChannelPortnread-writecurrentNumber of the last channel of the component :This OID defines the last channel number of the PM
1.3.6.1.4.1.20044.77.9.4.1.1.7Columnpm1604CfgGridPortnread-writecurrentGrid value of the component :This OID defines the grid of the PM
1.3.6.1.4.1.20044.77.9.257Scalarpm1604CfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.77.10Nodepm1604traps
1.3.6.1.4.1.20044.77.10.2Scalarpm1604trapPortNumberread-onlycurrentLast port which generates a trap
1.3.6.1.4.1.20044.77.10.3Scalarpm1604trapLineNumberread-onlycurrentLast Line which generates a trap
1.3.6.1.4.1.20044.77.10.4Scalarpm1604trapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.77.10.30Notificationpm1604Line2TrapNotUrgentGoesOncurrentNot urgent Line default is activated
1.3.6.1.4.1.20044.77.10.31Notificationpm1604Line2TrapNotUrgentGoesOffcurrentNot urgent Line default disappeared
1.3.6.1.4.1.20044.77.10.32Notificationpm1604Line2TrapUrgentGoesOncurrentUrgent Line default is activated
1.3.6.1.4.1.20044.77.10.33Notificationpm1604Line2TrapUrgentGoesOffcurrentUrgent Line default disappeared
1.3.6.1.4.1.20044.77.10.34Notificationpm1604Line2TrapCritGoesOncurrentCritical Line default is activated
1.3.6.1.4.1.20044.77.10.35Notificationpm1604Line2TrapCritGoesOffcurrentCritical Line default disappeared
1.3.6.1.4.1.20044.77.10.40Notificationpm1604Line1TrapNotUrgentGoesOncurrentNot urgent client default is activated
1.3.6.1.4.1.20044.77.10.41Notificationpm1604Line1TrapNotUrgentGoesOffcurrentNot urgent client default disappeared
1.3.6.1.4.1.20044.77.10.42Notificationpm1604Line1TrapUrgentGoesOncurrentUrgent client default is activated
1.3.6.1.4.1.20044.77.10.43Notificationpm1604Line1TrapUrgentGoesOffcurrentUrgent client default disappeared
1.3.6.1.4.1.20044.77.10.44Notificationpm1604Line1TrapCritGoesOncurrentCritical client default is activated
1.3.6.1.4.1.20044.77.10.45Notificationpm1604Line1TrapCritGoesOffcurrentCritical client default disappeared
1.3.6.1.4.1.20044.77.10.50Notificationpm1604PowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.77.10.51Notificationpm1604PowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared
Type Definitions
NameSyntaxStatusDescription
Pm1604ClientProtocolINTEGER { protocol10GBE(1), protocol8GFC(2), protocol10GFC(3), protocol16GFC(4) }currentDifferent values on the protocol on the client ports
Pm1604LineChannelINTEGERcurrentChannel selection on transceiver Line ports
Pm1604OtxGridINTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50) }currentDifferent grids on client and line ports