EKINOPS-Pm200frs02-MIB
868 objects
Creation.
Imported Objects
| EKINOPS-MIB | EkiApiState EkiMeasureType EkiMode ekinops EkiOnOff EkiProtocol EkiState EkiSynchroMode |
| SNMPv2-SMI | Counter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20044.90 | IdentitymodulePm200frs02 | Creation. | ||
| 1.3.6.1.4.1.20044.90.2 | Nodepm200frs02alarms | |||
| 1.3.6.1.4.1.20044.90.2.1 | Nodepm200frs02AlmOther | |||
| 1.3.6.1.4.1.20044.90.2.1.1 | Nodepm200frs02AlmOtherNurg | |||
| 1.3.6.1.4.1.20044.90.2.1.1.2 | Nodepm200frs02AlmsynthAlm2 | |||
| 1.3.6.1.4.1.20044.90.2.1.1.2.1 | Scalarpm200frs02AlmConfTableSave | read-only | current | PM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> infor… |
| 1.3.6.1.4.1.20044.90.2.1.1.2.2 | Scalarpm200frs02AlmInvUpload | read-only | current | Inventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> informationalStatus(1000) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.90.2.1.1.2.3 | Scalarpm200frs02AlmConfTableLoad | read-only | current | PM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> informationalStat… |
| 1.3.6.1.4.1.20044.90.2.1.1.2.4 | Scalarpm200frs02AlmCorrelatOff | read-only | current | Not Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> informationalStatus(1000) <Alarmtype… |
| 1.3.6.1.4.1.20044.90.2.1.1.2.5 | Scalarpm200frs02AlmMaintenanceOn | read-only | current | Maintenance Mode :This OID indicates that the RM is in maintenance mode. <Help> This alarm indicates that the maintenance mode is enabled on the PM <Condtype> … |
| 1.3.6.1.4.1.20044.90.2.1.1.338 | Nodepm200frs02AlmclientQsfpWarnDdm | |||
| 1.3.6.1.4.1.20044.90.2.1.1.338.1 | Scalarpm200frs02AlmTrscv1VccLowWng1 | read-only | current | Q1 Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Warning … |
| 1.3.6.1.4.1.20044.90.2.1.1.338.2 | Scalarpm200frs02AlmTrscv1VccHighWng1 | read-only | current | Q1 Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Warnin… |
| 1.3.6.1.4.1.20044.90.2.1.1.338.3 | Scalarpm200frs02AlmTrscv1TempLowWng1 | read-only | current | Q1 Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indicatin… |
| 1.3.6.1.4.1.20044.90.2.1.1.338.4 | Scalarpm200frs02AlmTrscv1TempHighWng1 | read-only | current | Q1 Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning indicat… |
| 1.3.6.1.4.1.20044.90.2.1.1.338.5 | Scalarpm200frs02AlmTrscv2VccLowWng1 | read-only | current | Q2 Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Warning … |
| 1.3.6.1.4.1.20044.90.2.1.1.338.6 | Scalarpm200frs02AlmTrscv2VccHighWng1 | read-only | current | Q2 Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Warnin… |
| 1.3.6.1.4.1.20044.90.2.1.1.338.7 | Scalarpm200frs02AlmTrscv2TempLowWng1 | read-only | current | Q2 Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indicatin… |
| 1.3.6.1.4.1.20044.90.2.1.1.338.8 | Scalarpm200frs02AlmTrscv2TempHighWng1 | read-only | current | Q2 Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning indicat… |
| 1.3.6.1.4.1.20044.90.2.1.2 | Nodepm200frs02AlmOtherUrg | |||
| 1.3.6.1.4.1.20044.90.2.1.2.337 | Nodepm200frs02AlmclientQsfpAlarmDdm | |||
| 1.3.6.1.4.1.20044.90.2.1.2.337.1 | Scalarpm200frs02AlmTrscv1VccLowAla1 | read-only | current | Q1 Trscv Power Supply Low Alarm :This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM <Help> Al… |
| 1.3.6.1.4.1.20044.90.2.1.2.337.2 | Scalarpm200frs02AlmTrscv1VccHighAla1 | read-only | current | Q1 Trscv Power Supply High Alarm :This OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM <Help> … |
| 1.3.6.1.4.1.20044.90.2.1.2.337.3 | Scalarpm200frs02AlmTrscv1TempLowAla1 | read-only | current | Q1 Trscv Temp Low Alarm :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indic… |
| 1.3.6.1.4.1.20044.90.2.1.2.337.4 | Scalarpm200frs02AlmTrscv1TempHighAla | read-only | current | Q1 Trscv Temp High Alarm :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm ind… |
| 1.3.6.1.4.1.20044.90.2.1.2.337.5 | Scalarpm200frs02AlmTrscv2VccLowAla1 | read-only | current | Q2 Trscv Power Supply Low Alarm :This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM <Help> Al… |
| 1.3.6.1.4.1.20044.90.2.1.2.337.6 | Scalarpm200frs02AlmTrscv2VccHighAla1 | read-only | current | Q2 Trscv Power Supply High Alarm :This OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM <Help> … |
| 1.3.6.1.4.1.20044.90.2.1.2.337.7 | Scalarpm200frs02AlmTrscv2TempLowAla1 | read-only | current | Q2 Trscv Temp Low Alarm :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indic… |
| 1.3.6.1.4.1.20044.90.2.1.2.337.8 | Scalarpm200frs02AlmTrscv2TempHighAla1 | read-only | current | Q2 Trscv Temp High Alarm :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm ind… |
| 1.3.6.1.4.1.20044.90.2.1.3 | Nodepm200frs02AlmOtherCrit | |||
| 1.3.6.1.4.1.20044.90.2.1.3.0 | Nodepm200frs02AlmsynthAlm0 | |||
| 1.3.6.1.4.1.20044.90.2.1.3.0.2 | Scalarpm200frs02AlmFailFan | read-only | current | Fan Fail :This OID is at 1 when any fail occurs on the fan tray <Help> This alarm indicates that the Fan tray module is in a failure condition <Condtype> FAIL_… |
| 1.3.6.1.4.1.20044.90.2.1.3.0.9 | Scalarpm200frs02AlmModGlobFail | read-only | current | Module Failure :This OID is set on detection of a failure originating from the RM <Help> This alarm is set on detection of a failure originating from the equip… |
| 1.3.6.1.4.1.20044.90.2.1.3.0.15 | Scalarpm200frs02AlmDefFuseA | read-only | current | Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.90.2.1.3.0.16 | Scalarpm200frs02AlmDefFuseB | read-only | current | Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.90.2.1.3.78 | Nodepm200frs02AlmmsaModuleState | |||
| 1.3.6.1.4.1.20044.90.2.1.3.78.1 | Scalarpm200frs02AlmMsaInitialize | read-only | current | Line Trscv Initialize :This OID indicates the Line Trscv initialization is in progress <Help> Status indicating the Line Trscv initialization is in progress <C… |
| 1.3.6.1.4.1.20044.90.2.1.3.78.2 | Scalarpm200frs02AlmMsaLowPower | read-only | current | Line Trscv Low Power :This OID indicates the Line Trscv is in low power state <Help> Status indicating the Line Trscv is in low power state <Condtype> MSA_LOW_… |
| 1.3.6.1.4.1.20044.90.2.1.3.78.3 | Scalarpm200frs02AlmMsaHighPowerUp | read-only | current | Line Trscv High Power Up :This OID indicates the Line Trscv is leaving Low Power state <Help> Status indicating the Line Trscv is leaving Low Power state <Cond… |
| 1.3.6.1.4.1.20044.90.2.1.3.78.4 | Scalarpm200frs02AlmMsaTxOff | read-only | current | Line Trscv Laser Shutdown :This OID indicates the Line Trscv Laser is OFF <Help> Status indicating the Line Trscv Laser is OFF <Condtype> MSA_TX_OFF <Probcause… |
| 1.3.6.1.4.1.20044.90.2.1.3.78.5 | Scalarpm200frs02AlmMsaTxTurnOn | read-only | current | Line Trscv Laser Turn On :This OID indicates the Line Trscv is turning on its laser <Help> Status indicating the Line Trscv is turning on its laser <Condtype> … |
| 1.3.6.1.4.1.20044.90.2.1.3.78.6 | Scalarpm200frs02AlmMsaReady | read-only | current | Line Trscv Ready :This OID indicates the Line Trscv is ready to operate <Help> Status indicating the Line Trscv is ready to operate <Condtype> MSA_READY <Probc… |
| 1.3.6.1.4.1.20044.90.2.1.3.78.7 | Scalarpm200frs02AlmMsaFault | read-only | current | Line Trscv Fault :This OID indicates the Line Trscv is in Fault state <Help> Status indicating the Line Trscv is in Fault state <Condtype> MSA_FAULT <Probcause… |
| 1.3.6.1.4.1.20044.90.2.1.3.78.8 | Scalarpm200frs02AlmMsaTxTurnOff | read-only | current | Line Trscv Laser Turn Off :This OID indicates the Line Trscv is turning off its laser <Help> Status indicating the Line Trscv is turning off its laser <Condtyp… |
| 1.3.6.1.4.1.20044.90.2.1.3.78.9 | Scalarpm200frs02AlmMsaHighPowerDown | read-only | current | Line Trscv High Power Down :This OID indicates the Line Trscv is entering Low Power state <Help> Status indicating the Line Trscv is entering Low Power state <… |
| 1.3.6.1.4.1.20044.90.2.2 | Nodepm200frs02AlmClient | |||
| 1.3.6.1.4.1.20044.90.2.2.1 | Nodepm200frs02AlmClientNurg | |||
| 1.3.6.1.4.1.20044.90.2.2.2 | Nodepm200frs02AlmClientUrg | |||
| 1.3.6.1.4.1.20044.90.2.2.2.152 | Tablepm200frs02AlmclientHostLaneFaultTable | not-accessible | current | List of pm200frs02AlmclientHostLaneFault Article |
| 1.3.6.1.4.1.20044.90.2.2.2.152.1 | Rowpm200frs02AlmclientHostLaneFaultEntry | not-accessible | current | Row definition for the pm200frs02AlmclientHostLaneFault table |
| 1.3.6.1.4.1.20044.90.2.2.2.152.1.1 | Columnpm200frs02AlmclientHostLaneFaultIndex | read-only | current | Index definition for the pm200frs02AlmclientHostLaneFault table |
| 1.3.6.1.4.1.20044.90.2.2.2.152.1.2 | Columnpm200frs02AlmClientLossOfSyncPortn | read-only | current | Client Frame Alignment Loss :This OID indicates the module is not aligned with the incoming Client signal <Help> Alarm indicating the module is not aligned wit… |
| 1.3.6.1.4.1.20044.90.2.2.2.152.1.3 | Columnpm200frs02AlmClientInputLossOfSigPortn | read-only | current | Client Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Client Trscv <Help> Alarm indicating a Loss of Signal is detected on the Cl… |
| 1.3.6.1.4.1.20044.90.2.2.2.152.1.4 | Columnpm200frs02AlmClientLanesMarkerUnlockPortn | read-only | current | Client Lanes Marker Unlock :This OID indicates the Client lanes marker alignment is not lock <Help> Alarm indicating the Client lanes marker alignment is not l… |
| 1.3.6.1.4.1.20044.90.2.2.2.152.1.5 | Columnpm200frs02AlmClientLanes6466UnlockPortn | read-only | current | Client Lanes 64/66b Unlock :This OID indicates the Client 64/66b decoder is not lock <Help> Alarm indicating the Client 64/66b decoder is not lock <Condtype> C… |
| 1.3.6.1.4.1.20044.90.2.2.2.152.1.6 | Columnpm200frs02AlmClientLanesNotAlignedPortn | read-only | current | Client Lanes Not Aligned :This OID indicates the Client lanes are not aligned <Help> Alarm indicating the Client lanes are not aligned <Condtype> CLIENT_LANES_… |
| 1.3.6.1.4.1.20044.90.2.2.2.152.1.7 | Columnpm200frs02AlmClientCsfDetectedPortn | read-only | current | Client Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client… |
| 1.3.6.1.4.1.20044.90.2.2.2.152.1.10 | Columnpm200frs02AlmClientTxHostLolPortn | read-only | current | Client Host Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Client Trscv Host Lane <Help> Alarm indicating a Tx Loss of Lock on the Client Tr… |
| 1.3.6.1.4.1.20044.90.2.2.2.152.1.11 | Columnpm200frs02AlmClientLaneTxFifoErrorPortn | read-only | current | Client Host Lane Tx FIFO Error :This OID indicates a Tx FIFO Error on the Client Trscv Host Lane <Help> Alarm indicating a Tx FIFO Error on the Client Trscv Ho… |
| 1.3.6.1.4.1.20044.90.2.2.3 | Nodepm200frs02AlmClientCrit | |||
| 1.3.6.1.4.1.20044.90.2.2.3.8 | Tablepm200frs02AlmsynthAlmPortTable | not-accessible | current | List of pm200frs02AlmsynthAlmPort Article |
| 1.3.6.1.4.1.20044.90.2.2.3.8.1 | Rowpm200frs02AlmsynthAlmPortEntry | not-accessible | current | Row definition for the pm200frs02AlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.90.2.2.3.8.1.1 | Columnpm200frs02AlmsynthAlmPortIndex | read-only | current | Index definition for the pm200frs02AlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.90.2.2.3.8.1.2 | Columnpm200frs02AlmSfpAbsentPortn | read-only | current | Client Optical Module Absent :This OID indicates that the Transceiver is not present in the client port. <Help> This alarm indicates if the client transceiver … |
| 1.3.6.1.4.1.20044.90.2.2.3.8.1.3 | Columnpm200frs02AlmDdmAbsentPortn | read-only | current | DDM Supported On Client Trscv :This OID indicates that the Client transceiver supports the Digital Diagnostic Monitoring function <Help> This status indicates … |
| 1.3.6.1.4.1.20044.90.2.2.3.8.1.5 | Columnpm200frs02AlmHwFailAccPortn | read-only | current | Client HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Help> This alarm indicates a failure on client port, most pro… |
| 1.3.6.1.4.1.20044.90.2.2.3.8.1.6 | Columnpm200frs02AlmDwLsdPortn | read-only | current | Client Trscv Laser Shutdown :This OID indicates the Client transceiver laser is shutdown <Help> This status indicates if the client transceiver laser is shutdo… |
| 1.3.6.1.4.1.20044.90.2.2.3.8.1.7 | Columnpm200frs02AlmClientLocalOosPortn | read-only | current | Local Client Port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local c… |
| 1.3.6.1.4.1.20044.90.2.2.3.8.1.8 | Columnpm200frs02AlmClientRemoteOosPortn | read-only | current | Remote Client Port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the remot… |
| 1.3.6.1.4.1.20044.90.2.2.3.8.1.9 | Columnpm200frs02AlmDwCaisPortn | read-only | current | Client AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indicates if a Client Alarm Indication Signal is… |
| 1.3.6.1.4.1.20044.90.2.2.3.8.1.10 | Columnpm200frs02AlmSfpDdmWarningPortn | read-only | current | Warning On Client Trscv DDM :This OID indicates a warning is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Warning has be… |
| 1.3.6.1.4.1.20044.90.2.2.3.8.1.11 | Columnpm200frs02AlmSfpDdmAlmPortn | read-only | current | Alarm On Client Trscv DDM :This OID indicates an alarm is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Alarm has been de… |
| 1.3.6.1.4.1.20044.90.2.2.3.8.1.13 | Columnpm200frs02AlmFailAccPortn | read-only | current | Client Access Fail :This OID indicates a failure on the Client port <Help> This alarm indicates a failure on the Client port <Condtype> FAIL_ACC_1 <Probcause> … |
| 1.3.6.1.4.1.20044.90.2.2.3.8.1.17 | Columnpm200frs02AlmUpCsfPortn | read-only | current | Client Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu… |
| 1.3.6.1.4.1.20044.90.2.3 | Nodepm200frs02AlmLine | |||
| 1.3.6.1.4.1.20044.90.2.3.1 | Nodepm200frs02AlmLineNurg | |||
| 1.3.6.1.4.1.20044.90.2.3.1.184 | Tablepm200frs02AlmlineNetworkLaneAlarmWarning1Table | not-accessible | current | List of pm200frs02AlmlineNetworkLaneAlarmWarning1 Article |
| 1.3.6.1.4.1.20044.90.2.3.1.184.1 | Rowpm200frs02AlmlineNetworkLaneAlarmWarning1Entry | not-accessible | current | Row definition for the pm200frs02AlmlineNetworkLaneAlarmWarning1 table |
| 1.3.6.1.4.1.20044.90.2.3.1.184.1.1 | Columnpm200frs02AlmlineNetworkLaneAlarmWarning1Index | read-only | current | Index definition for the pm200frs02AlmlineNetworkLaneAlarmWarning1 table |
| 1.3.6.1.4.1.20044.90.2.3.1.184.1.2 | Columnpm200frs02AlmLineRxPowerLowAlarmPortn | read-only | current | Line Trscv Rx Power Low Alarm :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicat… |
| 1.3.6.1.4.1.20044.90.2.3.1.184.1.3 | Columnpm200frs02AlmLineRxPowerLowWarningPortn | read-only | current | Line Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning ind… |
| 1.3.6.1.4.1.20044.90.2.3.1.184.1.4 | Columnpm200frs02AlmLineRxPowerHighWarningPortn | read-only | current | Line Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning i… |
| 1.3.6.1.4.1.20044.90.2.3.1.184.1.5 | Columnpm200frs02AlmLineRxPowerHighAlarmPortn | read-only | current | Line Trscv Rx Power High Alarm :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indic… |
| 1.3.6.1.4.1.20044.90.2.3.1.184.1.6 | Columnpm200frs02AlmLineLaserTempLowAlarmPortn | read-only | current | Line Trscv Tx Laser Temp Low Alarm :This OID indicates that the Trscv Tx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help>… |
| 1.3.6.1.4.1.20044.90.2.3.1.184.1.7 | Columnpm200frs02AlmLineLaserTempLowWarningPortn | read-only | current | Line Trscv Tx Laser Temp Low Warning :This OID indicates that the Trscv Tx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Hel… |
| 1.3.6.1.4.1.20044.90.2.3.1.184.1.8 | Columnpm200frs02AlmLineLaserTempHighWarningPortn | read-only | current | Line Trscv Tx Laser Temp High Warning :This OID indicates that the Trscv Tx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <H… |
| 1.3.6.1.4.1.20044.90.2.3.1.184.1.9 | Columnpm200frs02AlmLineLaserTempHighAlarmPortn | read-only | current | Line Trscv Tx Laser Temp High Alarm :This OID indicates that the Trscv Tx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Hel… |
| 1.3.6.1.4.1.20044.90.2.3.1.184.1.10 | Columnpm200frs02AlmLineTxPowerLowAlarmPortn | read-only | current | Line Trscv Tx Power Low Alarm :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indica… |
| 1.3.6.1.4.1.20044.90.2.3.1.184.1.11 | Columnpm200frs02AlmLineTxPowerLowWarningPortn | read-only | current | Line Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning in… |
| 1.3.6.1.4.1.20044.90.2.3.1.184.1.12 | Columnpm200frs02AlmLineTxPowerHighWarningPortn | read-only | current | Line Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warning … |
| 1.3.6.1.4.1.20044.90.2.3.1.184.1.13 | Columnpm200frs02AlmLineTxPowerHighAlarmPortn | read-only | current | Line Trscv Tx Power High Alarm :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indi… |
| 1.3.6.1.4.1.20044.90.2.3.1.184.1.14 | Columnpm200frs02AlmLineBiasLowAlarmPortn | read-only | current | Line Trscv Tx Bias Low Alarm :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alarm i… |
| 1.3.6.1.4.1.20044.90.2.3.1.184.1.15 | Columnpm200frs02AlmLineBiasLowWarningPortn | read-only | current | Line Trscv Tx Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warni… |
| 1.3.6.1.4.1.20044.90.2.3.1.184.1.16 | Columnpm200frs02AlmLineBiasHighWarningPortn | read-only | current | Line Trscv Tx Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> War… |
| 1.3.6.1.4.1.20044.90.2.3.1.184.1.17 | Columnpm200frs02AlmLineBiasHighAlarmPortn | read-only | current | Line Trscv Tx Bias High Alarm :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Alarm… |
| 1.3.6.1.4.1.20044.90.2.3.1.188 | Tablepm200frs02AlmlineNetworkLaneAlarmWarning2Table | not-accessible | current | List of pm200frs02AlmlineNetworkLaneAlarmWarning2 Article |
| 1.3.6.1.4.1.20044.90.2.3.1.188.1 | Rowpm200frs02AlmlineNetworkLaneAlarmWarning2Entry | not-accessible | current | Row definition for the pm200frs02AlmlineNetworkLaneAlarmWarning2 table |
| 1.3.6.1.4.1.20044.90.2.3.1.188.1.1 | Columnpm200frs02AlmlineNetworkLaneAlarmWarning2Index | read-only | current | Index definition for the pm200frs02AlmlineNetworkLaneAlarmWarning2 table |
| 1.3.6.1.4.1.20044.90.2.3.1.188.1.2 | Columnpm200frs02AlmTxModulatorBiasLowAlarmPortn | read-only | current | Line Trscv Tx Modulator Bias Low Alarm :This OID indicates that the Trscv Tx modulator bias current is lower than the threshold value written in the Trscv EEPR… |
| 1.3.6.1.4.1.20044.90.2.3.1.188.1.3 | Columnpm200frs02AlmTxModulatorBiasLowWarningPortn | read-only | current | Line Trscv Tx Modulator Bias Low Warning :This OID indicates that the Trscv Tx modulator bias current is lower than the threshold value written in the Trscv EE… |
| 1.3.6.1.4.1.20044.90.2.3.1.188.1.4 | Columnpm200frs02AlmTxModulatorBiasHighWarningPortn | read-only | current | Line Trscv Tx Modulator Bias High Warning :This OID indicates that the Trscv Tx modulator bias current is higher than the threshold value written in the Trscv … |
| 1.3.6.1.4.1.20044.90.2.3.1.188.1.5 | Columnpm200frs02AlmTxModulatorBiasHighAlarmPortn | read-only | current | Line Trscv Tx Modulator Bias High Alarm :This OID indicates that the Trscv Tx modulator bias current is higher than the threshold value written in the Trscv EE… |
| 1.3.6.1.4.1.20044.90.2.3.1.188.1.6 | Columnpm200frs02AlmRxLaserTempLowAlarmPortn | read-only | current | Line Trscv Rx Laser Temp Low Alarm :This OID indicates that the Trscv Rx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help>… |
| 1.3.6.1.4.1.20044.90.2.3.1.188.1.7 | Columnpm200frs02AlmRxLaserTempLowWarningPortn | read-only | current | Line Trscv Rx Laser Temp Low Warning :This OID indicates that the Trscv Rx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Hel… |
| 1.3.6.1.4.1.20044.90.2.3.1.188.1.8 | Columnpm200frs02AlmRxLaserTempHighWarningPortn | read-only | current | Line Trscv Rx Laser Temp High Warning :This OID indicates that the Trscv Rx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <H… |
| 1.3.6.1.4.1.20044.90.2.3.1.188.1.9 | Columnpm200frs02AlmRxLaserTempHighAlarmPortn | read-only | current | Line Trscv Rx Laser Temp High Alarm :This OID indicates that the Trscv Rx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Hel… |
| 1.3.6.1.4.1.20044.90.2.3.1.188.1.10 | Columnpm200frs02AlmRxLaserOutputLowAlarmPortn | read-only | current | Line Trscv Rx Output Power Low Alarm :This OID indicates that the Trscv Rx output power is lower than the threshold value written in the Trscv EEPROM <Help> Al… |
| 1.3.6.1.4.1.20044.90.2.3.1.188.1.11 | Columnpm200frs02AlmRxLaserOutputLowWarningPortn | read-only | current | Line Trscv Rx Output Power Low Warning :This OID indicates that the Trscv Rx output power is lower than the threshold value written in the Trscv EEPROM <Help> … |
| 1.3.6.1.4.1.20044.90.2.3.1.188.1.12 | Columnpm200frs02AlmRxLaserOutputHighWarningPortn | read-only | current | Line Trscv Rx Output Power High Warning :This OID indicates that the Trscv Rx output power is higher than the threshold value written in the Trscv EEPROM <Help… |
| 1.3.6.1.4.1.20044.90.2.3.1.188.1.13 | Columnpm200frs02AlmRxLaserOutputHighAlarmPortn | read-only | current | Line Trscv Rx Output Power High Alarm :This OID indicates that the Trscv Rx output power is higher than the threshold value written in the Trscv EEPROM <Help> … |
| 1.3.6.1.4.1.20044.90.2.3.1.188.1.14 | Columnpm200frs02AlmRxLaserBiasLowAlarmPortn | read-only | current | Line Trscv Rx Bias Low Alarm :This OID indicates that the Trscv Rx laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alar… |
| 1.3.6.1.4.1.20044.90.2.3.1.188.1.15 | Columnpm200frs02AlmRxLaserBiasLowWarningPortn | read-only | current | Line Trscv Rx Bias Low Warning :This OID indicates that the Trscv Rx laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Wa… |
| 1.3.6.1.4.1.20044.90.2.3.1.188.1.16 | Columnpm200frs02AlmRxLaserBiasHighWarningPortn | read-only | current | Line Trscv Rx Bias High Warning :This OID indicates that the Trscv Rx laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> … |
| 1.3.6.1.4.1.20044.90.2.3.1.188.1.17 | Columnpm200frs02AlmRxLaserBiasHighAlarmPortn | read-only | current | Line Trscv Rx Bias High Alarm :This OID indicates that the Trscv Rx laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Al… |
| 1.3.6.1.4.1.20044.90.2.3.2 | Nodepm200frs02AlmLineUrg | |||
| 1.3.6.1.4.1.20044.90.2.3.2.196 | Tablepm200frs02AlmlineHostLaneFaultTable | not-accessible | current | List of pm200frs02AlmlineHostLaneFault Article |
| 1.3.6.1.4.1.20044.90.2.3.2.196.1 | Rowpm200frs02AlmlineHostLaneFaultEntry | not-accessible | current | Row definition for the pm200frs02AlmlineHostLaneFault table |
| 1.3.6.1.4.1.20044.90.2.3.2.196.1.1 | Columnpm200frs02AlmlineHostLaneFaultIndex | read-only | current | Index definition for the pm200frs02AlmlineHostLaneFault table |
| 1.3.6.1.4.1.20044.90.2.3.2.196.1.2 | Columnpm200frs02AlmLineInputLossOfSignalPortn | read-only | current | Line Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Line Trscv <Help> Alarm indicating a Loss of Signal is detected on the Line T… |
| 1.3.6.1.4.1.20044.90.2.3.2.196.1.3 | Columnpm200frs02AlmLineLossOfFramePortn | read-only | current | Line Loss Of Frame :This OID indicates the module is not aligned with the incoming Line signal <Help> Alarm indicating the module is not aligned with the incom… |
| 1.3.6.1.4.1.20044.90.2.3.2.196.1.4 | Columnpm200frs02AlmLineSmBdiInsertedPortn | read-only | current | Line SM BDI Inserted :This OID indicates a SM Backward Defect Indication is inserted on the outgoing Line signal <Help> Status indicating a SM Backward Defect … |
| 1.3.6.1.4.1.20044.90.2.3.2.196.1.5 | Columnpm200frs02AlmLineSmBdiDetectedPortn | read-only | current | Line SM BDI Detected :This OID indicates a SM Backward Defect Indication is detected on the incoming Line signal <Help> Alarm indicating a SM Backward Defect I… |
| 1.3.6.1.4.1.20044.90.2.3.2.196.1.6 | Columnpm200frs02AlmLineSmIaeInsertedPortn | read-only | current | Line SM IAE Inserted :This OID indicates a SM Incoming Alignment Error is inserted on the outgoing Line signal <Help> Status indicating a SM Incoming Alignment… |
| 1.3.6.1.4.1.20044.90.2.3.2.196.1.7 | Columnpm200frs02AlmLineSmIaeDetectedPortn | read-only | current | Line SM IAE Detected :This OID indicates a SM Incoming Alignment Error is detected on the incoming Line signal <Help> Alarm indicating a SM Incoming Alignment … |
| 1.3.6.1.4.1.20044.90.2.3.2.196.1.10 | Columnpm200frs02AlmLineTxHostLolPortn | read-only | current | Line Host Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Line Trscv Host Lane <Help> Alarm indicating a Tx Loss of Lock on the Line Trscv Ho… |
| 1.3.6.1.4.1.20044.90.2.3.2.196.1.11 | Columnpm200frs02AlmLineLaneTxFifoErrorPortn | read-only | current | Line Host Lane Tx FIFO Error :This OID indicates a Tx FIFO Error on the Line Trscv Host Lane <Help> Alarm indicating a Tx FIFO Error on the Line Trscv Host Lan… |
| 1.3.6.1.4.1.20044.90.2.3.3 | Nodepm200frs02AlmLineCrit | |||
| 1.3.6.1.4.1.20044.90.2.3.3.40 | Tablepm200frs02AlmsynthAlmLineTable | not-accessible | current | List of pm200frs02AlmsynthAlmLine Article |
| 1.3.6.1.4.1.20044.90.2.3.3.40.1 | Rowpm200frs02AlmsynthAlmLineEntry | not-accessible | current | Row definition for the pm200frs02AlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.90.2.3.3.40.1.1 | Columnpm200frs02AlmsynthAlmLineIndex | read-only | current | Index definition for the pm200frs02AlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.90.2.3.3.40.1.2 | Columnpm200frs02AlmXfpAbsentPortn | read-only | current | Line Optical Module Absent :This OID indicates that the line optical interface is not present. <Help> This alarm indicates if the line transceiver is not plugg… |
| 1.3.6.1.4.1.20044.90.2.3.3.40.1.3 | Columnpm200frs02AlmXfpInitNotComplPortn | read-only | current | Line Optical Module Ready :This OID indicates that the optical interface is not operational. <Help> This status indicates if the line transceiver has been corr… |
| 1.3.6.1.4.1.20044.90.2.3.3.40.1.5 | Columnpm200frs02AlmLineHwFailPortn | read-only | current | Line Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Help> This alarm indicates a failure on line port, most pr… |
| 1.3.6.1.4.1.20044.90.2.3.3.40.1.6 | Columnpm200frs02AlmXfpTxOffPortn | read-only | current | Line Trscv Laser Shutdown :This OID indicates the Line transceiver laser is shutdown <Help> This status indicates if the Line transceiver laser is shutdown <Co… |
| 1.3.6.1.4.1.20044.90.2.3.3.40.1.7 | Columnpm200frs02AlmLineLocalOosPortn | read-only | current | Line Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service… |
| 1.3.6.1.4.1.20044.90.2.3.3.40.1.9 | Columnpm200frs02AlmUpRdiInsPortn | read-only | current | MS-RDI/L-RDI Inserted On Line :This OID indicates an upstream MS-RDI/L-RDI has been inserted in the outgoing 10 Gb/s SDH/SONET signal. <Help> This status indic… |
| 1.3.6.1.4.1.20044.90.2.3.3.40.1.10 | Columnpm200frs02AlmLineDdmWarningPortn | read-only | current | Warning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Warning has… |
| 1.3.6.1.4.1.20044.90.2.3.3.40.1.11 | Columnpm200frs02AlmLineDdmAlmPortn | read-only | current | Alarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Alarm has been… |
| 1.3.6.1.4.1.20044.90.2.3.3.40.1.13 | Columnpm200frs02AlmLineFailPortn | read-only | current | Line Port Failure :This OID indicates a failure on the line port <Help> This alarm indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipm… |
| 1.3.6.1.4.1.20044.90.2.3.3.40.1.17 | Columnpm200frs02AlmLineActivePortn | read-only | current | Line Active :This OID indicates whether the line is active or standby. <Help> This status indicates whether the line is active or standby. <Condtype> LINE_ACTI… |
| 1.3.6.1.4.1.20044.90.3 | Nodepm200frs02measures | |||
| 1.3.6.1.4.1.20044.90.3.1 | Nodepm200frs02MesrOther | |||
| 1.3.6.1.4.1.20044.90.3.1.0 | Scalarpm200frs02Mesrsynth0 | read-only | deprecated | Not Used : |
| 1.3.6.1.4.1.20044.90.3.1.1 | Scalarpm200frs02Mesrsynth1 | read-only | deprecated | Not Used : |
| 1.3.6.1.4.1.20044.90.3.1.7 | Scalarpm200frs02MesrpmIntervalNumber | read-only | current | PM Interval Counter : |
| 1.3.6.1.4.1.20044.90.3.1.196 | Scalarpm200frs02MesrlineNetTxLaserOutputPwrAverage | read-only | current | Average Line Trscv Tx Power :This OID gives the average Tx Laser transmit power value among the network lanes of the Line Transceiver, read in the DDM (Digital… |
| 1.3.6.1.4.1.20044.90.3.1.197 | Scalarpm200frs02MesrlineNetTxLaserTempAverage | read-only | current | Average Line Trscv Tx Laser Temperature :This OID gives the average Tx Laser Temperature value among the network lanes of the Line Transceiver, read from the D… |
| 1.3.6.1.4.1.20044.90.3.1.198 | Scalarpm200frs02MesrlineNetTxBiasCurrentAverage | read-only | current | Average Line Trscv Tx Laser Bias :This OID gives the average Tx Laser Bias value among the network lanes of the Line Transceiver, read from the DDM (Digital Di… |
| 1.3.6.1.4.1.20044.90.3.1.199 | Scalarpm200frs02MesrlineNetRxInputPwrAverage | read-only | current | Average Line Trscv Rx Power :This OID gives the average Receive power value among the network lanes of the Line Transceiver, read in the DDM (Digital Diagnosti… |
| 1.3.6.1.4.1.20044.90.3.1.200 | Scalarpm200frs02MesrlineResidualChromaticDispAverage | read-only | current | Average Residual Chromatic Dispersion :This OID gives the average Residual Chromatic Dispersion on the Line interface since the last measure reset (Dispersion … |
| 1.3.6.1.4.1.20044.90.3.1.201 | Scalarpm200frs02MesrlineDiffGroupDelayAverage | read-only | current | Average Differential Group Delay :This OID gives the average Group Delay on the Line interface since the last measure reset (Delay = AV_S16) (Unit = ps)<Help> … |
| 1.3.6.1.4.1.20044.90.3.1.202 | Scalarpm200frs02MesrlineQFactorAverage | read-only | current | Average Q Factor :This OID gives the average Q Factor on the Line interface since the last measure reset (Q Factor = AV_U16) (Unit = dB) <Help> This measure gi… |
| 1.3.6.1.4.1.20044.90.3.1.203 | Scalarpm200frs02MesrlineCarrierFreqOffsetAverage | read-only | current | Average Carrier Frequency Offset :This OID gives the average Carrier Frequency Offset on the Line interface since the last measure reset (Offset = AV_S16) (Uni… |
| 1.3.6.1.4.1.20044.90.3.1.204 | Scalarpm200frs02MesrlineOsnrAverage | read-only | current | Average OSNR :This OID gives the average OSNR on the Line interface since the last measure reset (OSNR = AV_S16/10) (Unit = dB)<Help> This measure gives the av… |
| 1.3.6.1.4.1.20044.90.3.1.212 | Scalarpm200frs02MesrlineNetTxLaserOutputPwrMin | read-only | current | Min Line Trscv Tx Power :This OID gives the minimum Tx Laser transmit power value among the network lanes of the Line Transceiver, read in the DDM (Digital Dia… |
| 1.3.6.1.4.1.20044.90.3.1.213 | Scalarpm200frs02MesrlineNetTxLaserTempMin | read-only | current | Min Line Trscv Tx Laser Temperature :This OID gives the minimum Tx Laser Temperature value among the network lanes of the Line Transceiver, read from the DDM (… |
| 1.3.6.1.4.1.20044.90.3.1.214 | Scalarpm200frs02MesrlineNetTxBiasCurrentMin | read-only | current | Min Line Trscv Tx Laser Bias :This OID gives the minimum Tx Laser Bias value among the network lanes of the Line Transceiver, read from the DDM (Digital Diagno… |
| 1.3.6.1.4.1.20044.90.3.1.215 | Scalarpm200frs02MesrlineNetRxInputPwrMin | read-only | current | Min Line Trscv Rx Power :This OID gives the minimum Receive power value among the network lanes of the Line Transceiver, read in the DDM (Digital Diagnostic Mo… |
| 1.3.6.1.4.1.20044.90.3.1.216 | Scalarpm200frs02MesrlineResidualChromaticDispMin | read-only | current | Min Residual Chromatic Dispersion :This OID gives the minimum Residual Chromatic Dispersion on the Line interface since the last measure reset (Dispersion = AV… |
| 1.3.6.1.4.1.20044.90.3.1.217 | Scalarpm200frs02MesrlineDiffGroupDelayMin | read-only | current | Min Differential Group Delay :This OID gives the minimum Differential Group Delay on the Line interface since the last measure reset (Delay = AV_S16) (Unit = p… |
| 1.3.6.1.4.1.20044.90.3.1.218 | Scalarpm200frs02MesrlineQFactorMin | read-only | current | Min Q Factor :This OID gives the minimum Q Factor on the Line interface since the last measure reset (Q Factor = AV_U16) (Unit = dB)<Help> This measure gives t… |
| 1.3.6.1.4.1.20044.90.3.1.219 | Scalarpm200frs02MesrlineCarrierFreqOffsetMin | read-only | current | Min Carrier Frequency Offset :This OID gives the minimum Carrier Frequency Offset on the Line interface since the last measure reset (Offset = AV_S16) (Unit = … |
| 1.3.6.1.4.1.20044.90.3.1.220 | Scalarpm200frs02MesrlineOsnrMin | read-only | current | Min OSNR :This OID gives the minimum OSNR on the Line interface since the last measure reset (OSNR = AV_S16/10) (Unit = dB)<Help> This measure gives the minimu… |
| 1.3.6.1.4.1.20044.90.3.1.228 | Scalarpm200frs02MesrlineNetTxLaserOutputPwrMax | read-only | current | Max Line Trscv Tx Power :This OID gives the maximum Tx Laser transmit power value among the network lanes of the Line Transceiver, read in the DDM (Digital Dia… |
| 1.3.6.1.4.1.20044.90.3.1.229 | Scalarpm200frs02MesrlineNetTxLaserTempMax | read-only | current | Max Line Trscv Tx Laser Temperature :This OID gives the maximum Tx Laser Temperature value among the network lanes of the Line Transceiver, read from the DDM (… |
| 1.3.6.1.4.1.20044.90.3.1.230 | Scalarpm200frs02MesrlineNetTxBiasCurrentMax | read-only | current | Max Line Trscv Tx Laser Bias :This OID gives the maximum Tx Laser Bias value among the network lanes of the Line Transceiver, read from the DDM (Digital Diagno… |
| 1.3.6.1.4.1.20044.90.3.1.231 | Scalarpm200frs02MesrlineNetRxInputPwrMax | read-only | current | Max Line Trscv Rx Power :This OID gives the maximum Receive power value among the network lanes of the Line Transceiver, read in the DDM (Digital Diagnostic Mo… |
| 1.3.6.1.4.1.20044.90.3.1.232 | Scalarpm200frs02MesrlineResidualChromaticDispMax | read-only | current | Max Residual Chromatic Dispersion :This OID gives the maximum Residual Chromatic Dispersion on the Line interface since the last measure reset (Dispersion = AV… |
| 1.3.6.1.4.1.20044.90.3.1.233 | Scalarpm200frs02MesrlineDiffGroupDelayMax | read-only | current | Max Differential Group Delay :This OID gives the maximum Differential Group Delay on the Line interface since the last measure reset (Delay = AV_S16) (Unit = p… |
| 1.3.6.1.4.1.20044.90.3.1.234 | Scalarpm200frs02MesrlineQFactorMax | read-only | current | Max Q Factor :This OID gives the maximum Q Factor on the Line interface since the last measure reset (Q Factor = AV_U16) (Unit = dB)<Help> This measure gives t… |
| 1.3.6.1.4.1.20044.90.3.1.235 | Scalarpm200frs02MesrlineCarrierFreqOffsetMax | read-only | current | Max Carrier Frequency Offset :This OID gives the maximum Carrier Frequency Offset on the Line interface since the last measure reset (Offset = AV_S16) (Unit = … |
| 1.3.6.1.4.1.20044.90.3.1.236 | Scalarpm200frs02MesrlineOsnrMax | read-only | current | Max OSNR :This OID gives the maximum OSNR on the Line interface since the last measure reset (OSNR = AV_S16/10) (Unit = dB)<Help> This measure gives the maximu… |
| 1.3.6.1.4.1.20044.90.3.1.249 | Scalarpm200frs02MesrregVoltage | read-only | current | Regulator Voltage :This OID gives the voltage value of the Regulator (Voltage = AV_U16) (Unit = mV) <Help> This Measure gives the Regulator Voltage |
| 1.3.6.1.4.1.20044.90.3.1.250 | Scalarpm200frs02MesrregCurrent | read-only | current | Regulator Current :This OID gives the current value of the Regulator (Current = AV_U16/1000) (Unit = A) <Help> This Measure gives the Regulator Current |
| 1.3.6.1.4.1.20044.90.3.1.251 | Scalarpm200frs02MesrregTemp | read-only | current | Regulator Temperature :This OID gives the temperature value of the Regulator (Temperature = AV_S16) (Unit = C) <Help> This Measure gives the Regulator Temperat… |
| 1.3.6.1.4.1.20044.90.3.1.252 | Scalarpm200frs02Mesrtrscv1Temp | read-only | current | Q1 Trscv Temperature :This OID gives the temperature value of the Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV_S16/256) (Un… |
| 1.3.6.1.4.1.20044.90.3.1.253 | Scalarpm200frs02Mesrtrscv2Temp | read-only | current | Q2 Trscv Temperature :This OID gives the temperature value of the Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV_S16/256) (Un… |
| 1.3.6.1.4.1.20044.90.3.1.254 | Scalarpm200frs02Mesrtrscv1PowerSupply | read-only | current | Q1 Trscv Voltage :This OID gives the voltage value of the QSFP plugged into the port, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV_U16/10000… |
| 1.3.6.1.4.1.20044.90.3.1.255 | Scalarpm200frs02Mesrtrscv2PowerSupply | read-only | current | Q2 Trscv Voltage :This OID gives the voltage value of the QSFP plugged into the port, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV_U16/10000… |
| 1.3.6.1.4.1.20044.90.3.2 | Nodepm200frs02MesrClient | |||
| 1.3.6.1.4.1.20044.90.3.2.8 | Scalarpm200frs02MesrclientCfpTemp | read-only | current | Client Trscv Temperature :This OID gives the temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV_S… |
| 1.3.6.1.4.1.20044.90.3.2.9 | Scalarpm200frs02MesrclientCfp3v3Voltage | read-only | current | Client Trscv Voltage :This OID gives the 3V3 voltage value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV_U16/10000… |
| 1.3.6.1.4.1.20044.90.3.2.10 | Scalarpm200frs02MesrclientSoaBiasCurrent | read-only | current | Client Trscv SOA Bias :This OID gives the SOA bias value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV_U16/500) (Unit… |
| 1.3.6.1.4.1.20044.90.3.2.16 | Tablepm200frs02MesrclientTxPwrMinTable | not-accessible | current | List of pm200frs02MesrclientTxPwrMin Article |
| 1.3.6.1.4.1.20044.90.3.2.16.1 | Rowpm200frs02MesrclientTxPwrMinEntry | not-accessible | current | Row definition for the pm200frs02MesrclientTxPwrMin table |
| 1.3.6.1.4.1.20044.90.3.2.16.1.1 | Columnpm200frs02MesrclientTxPwrMinIndex | read-only | current | Index definition for the pm200frs02MesrclientTxPwrMin table |
| 1.3.6.1.4.1.20044.90.3.2.16.1.2 | Columnpm200frs02MesrclientTxPwrMinPortn | read-only | current | Min Client Trscv Tx Power Per Lane :This OID gives the minimum transmit power value among the network lanes of the Client Transceiver, read from the DDM (Digit… |
| 1.3.6.1.4.1.20044.90.3.2.48 | Tablepm200frs02MesrclientRxPwrMinTable | not-accessible | current | List of pm200frs02MesrclientRxPwrMin Article |
| 1.3.6.1.4.1.20044.90.3.2.48.1 | Rowpm200frs02MesrclientRxPwrMinEntry | not-accessible | current | Row definition for the pm200frs02MesrclientRxPwrMin table |
| 1.3.6.1.4.1.20044.90.3.2.48.1.1 | Columnpm200frs02MesrclientRxPwrMinIndex | read-only | current | Index definition for the pm200frs02MesrclientRxPwrMin table |
| 1.3.6.1.4.1.20044.90.3.2.48.1.2 | Columnpm200frs02MesrclientRxPwrMinPortn | read-only | current | Min Client Trscv Rx Power Per Lane :This OID gives the minimum receive power value among the network lanes of the Client Transceiver, read from the DDM (Digita… |
| 1.3.6.1.4.1.20044.90.3.2.80 | Tablepm200frs02MesrclientTxPwrMaxTable | not-accessible | current | List of pm200frs02MesrclientTxPwrMax Article |
| 1.3.6.1.4.1.20044.90.3.2.80.1 | Rowpm200frs02MesrclientTxPwrMaxEntry | not-accessible | current | Row definition for the pm200frs02MesrclientTxPwrMax table |
| 1.3.6.1.4.1.20044.90.3.2.80.1.1 | Columnpm200frs02MesrclientTxPwrMaxIndex | read-only | current | Index definition for the pm200frs02MesrclientTxPwrMax table |
| 1.3.6.1.4.1.20044.90.3.2.80.1.2 | Columnpm200frs02MesrclientTxPwrMaxPortn | read-only | current | Max Client Trscv Tx Power Per Lane :This OID gives the maximum transmit power value among the network lanes of the Client Transceiver, read from the DDM (Digit… |
| 1.3.6.1.4.1.20044.90.3.2.112 | Tablepm200frs02MesrclientRxPwrMaxTable | not-accessible | current | List of pm200frs02MesrclientRxPwrMax Article |
| 1.3.6.1.4.1.20044.90.3.2.112.1 | Rowpm200frs02MesrclientRxPwrMaxEntry | not-accessible | current | Row definition for the pm200frs02MesrclientRxPwrMax table |
| 1.3.6.1.4.1.20044.90.3.2.112.1.1 | Columnpm200frs02MesrclientRxPwrMaxIndex | read-only | current | Index definition for the pm200frs02MesrclientRxPwrMax table |
| 1.3.6.1.4.1.20044.90.3.2.112.1.2 | Columnpm200frs02MesrclientRxPwrMaxPortn | read-only | current | Max Client Trscv Rx Power Per Lane :This OID gives the maximum receive power value among the network lanes of the Client Transceiver, read in the DDM (Digital … |
| 1.3.6.1.4.1.20044.90.3.2.256 | Tablepm200frs02MesrclientTxCompositePwrTable | not-accessible | current | List of pm200frs02MesrclientTxCompositePwr Article |
| 1.3.6.1.4.1.20044.90.3.2.256.1 | Rowpm200frs02MesrclientTxCompositePwrEntry | not-accessible | current | Row definition for the pm200frs02MesrclientTxCompositePwr table |
| 1.3.6.1.4.1.20044.90.3.2.256.1.1 | Columnpm200frs02MesrclientTxCompositePwrIndex | read-only | current | Index definition for the pm200frs02MesrclientTxCompositePwr table |
| 1.3.6.1.4.1.20044.90.3.2.256.1.2 | Columnpm200frs02MesrclientTxCompositePwrPortn | read-only | current | Client Composite Tx Power (LR4/SR4) :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver, read from… |
| 1.3.6.1.4.1.20044.90.3.2.288 | Tablepm200frs02MesrclientRxCompositePwrTable | not-accessible | current | List of pm200frs02MesrclientRxCompositePwr Article |
| 1.3.6.1.4.1.20044.90.3.2.288.1 | Rowpm200frs02MesrclientRxCompositePwrEntry | not-accessible | current | Row definition for the pm200frs02MesrclientRxCompositePwr table |
| 1.3.6.1.4.1.20044.90.3.2.288.1.1 | Columnpm200frs02MesrclientRxCompositePwrIndex | read-only | current | Index definition for the pm200frs02MesrclientRxCompositePwr table |
| 1.3.6.1.4.1.20044.90.3.2.288.1.2 | Columnpm200frs02MesrclientRxCompositePwrPortn | read-only | current | Client Composite Rx Power (LR4/SR4) :This OID gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver, read from t… |
| 1.3.6.1.4.1.20044.90.3.3 | Nodepm200frs02MesrLine | |||
| 1.3.6.1.4.1.20044.90.3.3.12 | Scalarpm200frs02MesrlineMsaTemp | read-only | current | Line Trscv Temperature :This OID gives the temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV_S16/2… |
| 1.3.6.1.4.1.20044.90.3.3.13 | Scalarpm200frs02MesrlineMsa3v3Voltage | read-only | current | Line Trscv Voltage :This OID gives the 3V3 voltage value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV_U16/10000) (U… |
| 1.3.6.1.4.1.20044.90.3.3.14 | Scalarpm200frs02MesrlineSoaBiasCurrent | read-only | current | Line Trscv SOA Bias :This OID gives the SOA bias value of the Line Transceiver,read from the DDM (Digital Diagnostic Monitoring) (Bias = AV_U16/500) (Unit = mA… |
| 1.3.6.1.4.1.20044.90.3.3.144 | Tablepm200frs02MesrlineNetTxLaserOutputPwrTable | not-accessible | current | List of pm200frs02MesrlineNetTxLaserOutputPwr Article |
| 1.3.6.1.4.1.20044.90.3.3.144.1 | Rowpm200frs02MesrlineNetTxLaserOutputPwrEntry | not-accessible | current | Row definition for the pm200frs02MesrlineNetTxLaserOutputPwr table |
| 1.3.6.1.4.1.20044.90.3.3.144.1.1 | Columnpm200frs02MesrlineNetTxLaserOutputPwrIndex | read-only | current | Index definition for the pm200frs02MesrlineNetTxLaserOutputPwr table |
| 1.3.6.1.4.1.20044.90.3.3.144.1.2 | Columnpm200frs02MesrlineNetTxLaserOutputPwrPortn | read-only | current | Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power =… |
| 1.3.6.1.4.1.20044.90.3.3.148 | Tablepm200frs02MesrlineNetTxLaserTempTable | not-accessible | current | List of pm200frs02MesrlineNetTxLaserTemp Article |
| 1.3.6.1.4.1.20044.90.3.3.148.1 | Rowpm200frs02MesrlineNetTxLaserTempEntry | not-accessible | current | Row definition for the pm200frs02MesrlineNetTxLaserTemp table |
| 1.3.6.1.4.1.20044.90.3.3.148.1.1 | Columnpm200frs02MesrlineNetTxLaserTempIndex | read-only | current | Index definition for the pm200frs02MesrlineNetTxLaserTemp table |
| 1.3.6.1.4.1.20044.90.3.3.148.1.2 | Columnpm200frs02MesrlineNetTxLaserTempPortn | read-only | current | Current Line Trscv Tx Laser Temperature :This OID gives the Tx Laser Temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitorin… |
| 1.3.6.1.4.1.20044.90.3.3.152 | Tablepm200frs02MesrlineNetTxBiasCurrentTable | not-accessible | current | List of pm200frs02MesrlineNetTxBiasCurrent Article |
| 1.3.6.1.4.1.20044.90.3.3.152.1 | Rowpm200frs02MesrlineNetTxBiasCurrentEntry | not-accessible | current | Row definition for the pm200frs02MesrlineNetTxBiasCurrent table |
| 1.3.6.1.4.1.20044.90.3.3.152.1.1 | Columnpm200frs02MesrlineNetTxBiasCurrentIndex | read-only | current | Index definition for the pm200frs02MesrlineNetTxBiasCurrent table |
| 1.3.6.1.4.1.20044.90.3.3.152.1.2 | Columnpm200frs02MesrlineNetTxBiasCurrentPortn | read-only | current | Current Line Trscv Tx Laser Bias :This OID gives the Tx Laser Bias value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV_… |
| 1.3.6.1.4.1.20044.90.3.3.156 | Tablepm200frs02MesrlineNetRxInputPwrTable | not-accessible | current | List of pm200frs02MesrlineNetRxInputPwr Article |
| 1.3.6.1.4.1.20044.90.3.3.156.1 | Rowpm200frs02MesrlineNetRxInputPwrEntry | not-accessible | current | Row definition for the pm200frs02MesrlineNetRxInputPwr table |
| 1.3.6.1.4.1.20044.90.3.3.156.1.1 | Columnpm200frs02MesrlineNetRxInputPwrIndex | read-only | current | Index definition for the pm200frs02MesrlineNetRxInputPwr table |
| 1.3.6.1.4.1.20044.90.3.3.156.1.2 | Columnpm200frs02MesrlineNetRxInputPwrPortn | read-only | current | Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/10… |
| 1.3.6.1.4.1.20044.90.3.3.160 | Tablepm200frs02MesrlineResidualChromaticDispTable | not-accessible | current | List of pm200frs02MesrlineResidualChromaticDisp Article |
| 1.3.6.1.4.1.20044.90.3.3.160.1 | Rowpm200frs02MesrlineResidualChromaticDispEntry | not-accessible | current | Row definition for the pm200frs02MesrlineResidualChromaticDisp table |
| 1.3.6.1.4.1.20044.90.3.3.160.1.1 | Columnpm200frs02MesrlineResidualChromaticDispIndex | read-only | current | Index definition for the pm200frs02MesrlineResidualChromaticDisp table |
| 1.3.6.1.4.1.20044.90.3.3.160.1.2 | Columnpm200frs02MesrlineResidualChromaticDispPortn | read-only | current | Current Residual Chromatic Dispersion :This OID gives the current Residual Chromatic Dispersion on the Line interface (Dispersion = AV_S16*(-2)) (Unit = ps/nm)… |
| 1.3.6.1.4.1.20044.90.3.3.164 | Tablepm200frs02MesrlineDiffGroupDelayTable | not-accessible | current | List of pm200frs02MesrlineDiffGroupDelay Article |
| 1.3.6.1.4.1.20044.90.3.3.164.1 | Rowpm200frs02MesrlineDiffGroupDelayEntry | not-accessible | current | Row definition for the pm200frs02MesrlineDiffGroupDelay table |
| 1.3.6.1.4.1.20044.90.3.3.164.1.1 | Columnpm200frs02MesrlineDiffGroupDelayIndex | read-only | current | Index definition for the pm200frs02MesrlineDiffGroupDelay table |
| 1.3.6.1.4.1.20044.90.3.3.164.1.2 | Columnpm200frs02MesrlineDiffGroupDelayPortn | read-only | current | Current Differential Group Delay :This OID gives the current Differential Group Delay on the Line interface (Delay = AV_S16) (Unit = ps)<Help> This measure giv… |
| 1.3.6.1.4.1.20044.90.3.3.168 | Tablepm200frs02MesrlineQFactorTable | not-accessible | current | List of pm200frs02MesrlineQFactor Article |
| 1.3.6.1.4.1.20044.90.3.3.168.1 | Rowpm200frs02MesrlineQFactorEntry | not-accessible | current | Row definition for the pm200frs02MesrlineQFactor table |
| 1.3.6.1.4.1.20044.90.3.3.168.1.1 | Columnpm200frs02MesrlineQFactorIndex | read-only | current | Index definition for the pm200frs02MesrlineQFactor table |
| 1.3.6.1.4.1.20044.90.3.3.168.1.2 | Columnpm200frs02MesrlineQFactorPortn | read-only | current | Current Q Factor :This OID gives the current Q Factor on the Line interface (Q Factor = AV_U16) (Unit = dB) <Help> This measure gives the current Q Factor on t… |
| 1.3.6.1.4.1.20044.90.3.3.172 | Tablepm200frs02MesrlineCarrierFreqOffsetTable | not-accessible | current | List of pm200frs02MesrlineCarrierFreqOffset Article |
| 1.3.6.1.4.1.20044.90.3.3.172.1 | Rowpm200frs02MesrlineCarrierFreqOffsetEntry | not-accessible | current | Row definition for the pm200frs02MesrlineCarrierFreqOffset table |
| 1.3.6.1.4.1.20044.90.3.3.172.1.1 | Columnpm200frs02MesrlineCarrierFreqOffsetIndex | read-only | current | Index definition for the pm200frs02MesrlineCarrierFreqOffset table |
| 1.3.6.1.4.1.20044.90.3.3.172.1.2 | Columnpm200frs02MesrlineCarrierFreqOffsetPortn | read-only | current | Current Carrier Frequency Offset :This OID gives the current Carrier Frequency Offset on the Line interface (Offset = AV_S16) (Unit = MHz)<Help> This measure g… |
| 1.3.6.1.4.1.20044.90.3.3.176 | Tablepm200frs02MesrlineOsnrTable | not-accessible | current | List of pm200frs02MesrlineOsnr Article |
| 1.3.6.1.4.1.20044.90.3.3.176.1 | Rowpm200frs02MesrlineOsnrEntry | not-accessible | current | Row definition for the pm200frs02MesrlineOsnr table |
| 1.3.6.1.4.1.20044.90.3.3.176.1.1 | Columnpm200frs02MesrlineOsnrIndex | read-only | current | Index definition for the pm200frs02MesrlineOsnr table |
| 1.3.6.1.4.1.20044.90.3.3.176.1.2 | Columnpm200frs02MesrlineOsnrPortn | read-only | current | Current OSNR :This OID gives the current OSNR on the Line interface (OSNR = AV_S16/10) (Unit = dB)<Help> This measure gives the current OSNR on the Line interf… |
| 1.3.6.1.4.1.20044.90.4 | Nodepm200frs02counters | |||
| 1.3.6.1.4.1.20044.90.4.1 | Nodepm200frs02CntOther | |||
| 1.3.6.1.4.1.20044.90.4.2 | Nodepm200frs02CntClient | |||
| 1.3.6.1.4.1.20044.90.4.2.112 | Tablepm200frs02CntclientInputErrorCounterTable | not-accessible | current | List of pm200frs02CntclientInputErrorCounter Article |
| 1.3.6.1.4.1.20044.90.4.2.112.1 | Rowpm200frs02CntclientInputErrorCounterEntry | not-accessible | current | Row definition for the pm200frs02CntclientInputErrorCounter table |
| 1.3.6.1.4.1.20044.90.4.2.112.1.1 | Columnpm200frs02CntclientInputErrorCounterIndex | read-only | current | Index definition for the pm200frs02CntclientInputErrorCounter table |
| 1.3.6.1.4.1.20044.90.4.2.112.1.2 | Columnpm200frs02CntclientInputErrorCounterValuePortn | read-only | current | Client Input Errors :This counter gives the number of SM-BIP8 on the client port (OTU4 only) <Help> This counter gives the number of SM-BIP8 on the client port… |
| 1.3.6.1.4.1.20044.90.4.2.112.1.3 | Columnpm200frs02CntclientInputErrorCounterErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the BIP8 error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.90.4.2.112.1.4 | Columnpm200frs02CntclientInputErrorCounterOverloadPortn | read-only | current | Client Counter Overload :This OID when set indicates a BIP8 error counter overload on Port |
| 1.3.6.1.4.1.20044.90.4.2.144 | Tablepm200frs02CntclientCbipCounterTable | not-accessible | current | List of pm200frs02CntclientCbipCounter Article |
| 1.3.6.1.4.1.20044.90.4.2.144.1 | Rowpm200frs02CntclientCbipCounterEntry | not-accessible | current | Row definition for the pm200frs02CntclientCbipCounter table |
| 1.3.6.1.4.1.20044.90.4.2.144.1.1 | Columnpm200frs02CntclientCbipCounterIndex | read-only | current | Index definition for the pm200frs02CntclientCbipCounter table |
| 1.3.6.1.4.1.20044.90.4.2.144.1.2 | Columnpm200frs02CntclientCbipCounterValuePortn | read-only | current | Client Output Errors :This counter gives the number of SM-BIP8 on the client port (OTU4 only) <Help> This counter gives the number of SM-BIP8 on the client por… |
| 1.3.6.1.4.1.20044.90.4.2.144.1.3 | Columnpm200frs02CntclientCbipCounterErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the BIP8 error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.90.4.2.144.1.4 | Columnpm200frs02CntclientCbipCounterOverloadPortn | read-only | current | Client CBIP Counter Overload :This OID when set indicates a BIP8 error counter overload on Port |
| 1.3.6.1.4.1.20044.90.4.3 | Nodepm200frs02CntLine | |||
| 1.3.6.1.4.1.20044.90.4.3.192 | Tablepm200frs02CntlocalLineSmBip8ErrorCounterTable | not-accessible | current | List of pm200frs02CntlocalLineSmBip8ErrorCounter Article |
| 1.3.6.1.4.1.20044.90.4.3.192.1 | Rowpm200frs02CntlocalLineSmBip8ErrorCounterEntry | not-accessible | current | Row definition for the pm200frs02CntlocalLineSmBip8ErrorCounter table |
| 1.3.6.1.4.1.20044.90.4.3.192.1.1 | Columnpm200frs02CntlocalLineSmBip8ErrorCounterIndex | read-only | current | Index definition for the pm200frs02CntlocalLineSmBip8ErrorCounter table |
| 1.3.6.1.4.1.20044.90.4.3.192.1.2 | Columnpm200frs02CntlocalLineSmBip8ErrorCounterValuePortn | read-only | current | Uncorrected FEC Errors :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC <Help> This counter gives the current Bit Error Rate (resi… |
| 1.3.6.1.4.1.20044.90.4.3.192.1.3 | Columnpm200frs02CntlocalLineSmBip8ErrorCounterErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the B1 error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.90.4.3.192.1.4 | Columnpm200frs02CntlocalLineSmBip8ErrorCounterOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a B1 error counter overload on Port |
| 1.3.6.1.4.1.20044.90.4.3.193 | Tablepm200frs02CntlocalLineFecCorrectedErrorsCounterTable | not-accessible | current | List of pm200frs02CntlocalLineFecCorrectedErrorsCounter Article |
| 1.3.6.1.4.1.20044.90.4.3.193.1 | Rowpm200frs02CntlocalLineFecCorrectedErrorsCounterEntry | not-accessible | current | Row definition for the pm200frs02CntlocalLineFecCorrectedErrorsCounter table |
| 1.3.6.1.4.1.20044.90.4.3.193.1.1 | Columnpm200frs02CntlocalLineFecCorrectedErrorsCounterIndex | read-only | current | Index definition for the pm200frs02CntlocalLineFecCorrectedErrorsCounter table |
| 1.3.6.1.4.1.20044.90.4.3.193.1.2 | Columnpm200frs02CntlocalLineFecCorrectedErrorsCounterValuePortn | read-only | current | Line Input HD FEC Corrected Errors :This OID gives the current Bit Error Rate before the Hard Decision FEC <Help> This counter gives the current Bit Error Rate… |
| 1.3.6.1.4.1.20044.90.4.3.193.1.3 | Columnpm200frs02CntlocalLineFecCorrectedErrorsCounterErrorPortn | read-only | current | FEC Counter Error :This bit when set indicates the FEC corrected errors counter value is invalid on Line |
| 1.3.6.1.4.1.20044.90.4.3.193.1.4 | Columnpm200frs02CntlocalLineFecCorrectedErrorsCounterOverloadPortn | read-only | current | FEC Counter Overload :This bit when set indicates a FEC corrected errors counter overload on Line |
| 1.3.6.1.4.1.20044.90.4.3.194 | Tablepm200frs02CntremoteLineSmBip8ErrorCounterTable | not-accessible | current | List of pm200frs02CntremoteLineSmBip8ErrorCounter Article |
| 1.3.6.1.4.1.20044.90.4.3.194.1 | Rowpm200frs02CntremoteLineSmBip8ErrorCounterEntry | not-accessible | current | Row definition for the pm200frs02CntremoteLineSmBip8ErrorCounter table |
| 1.3.6.1.4.1.20044.90.4.3.194.1.1 | Columnpm200frs02CntremoteLineSmBip8ErrorCounterIndex | read-only | current | Index definition for the pm200frs02CntremoteLineSmBip8ErrorCounter table |
| 1.3.6.1.4.1.20044.90.4.3.194.1.2 | Columnpm200frs02CntremoteLineSmBip8ErrorCounterValuePortn | read-only | current | Remote SM BIP8 :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC on the remote side <Help> This counter gives the current Bit Error… |
| 1.3.6.1.4.1.20044.90.4.3.194.1.3 | Columnpm200frs02CntremoteLineSmBip8ErrorCounterErrorPortn | read-only | current | Remote Counter Error : |
| 1.3.6.1.4.1.20044.90.4.3.194.1.4 | Columnpm200frs02CntremoteLineSmBip8ErrorCounterOverloadPortn | read-only | current | Remote Counter Overload : |
| 1.3.6.1.4.1.20044.90.4.3.195 | Tablepm200frs02CntlineDfrmTimCntTable | not-accessible | current | List of pm200frs02CntlineDfrmTimCnt Article |
| 1.3.6.1.4.1.20044.90.4.3.195.1 | Rowpm200frs02CntlineDfrmTimCntEntry | not-accessible | current | Row definition for the pm200frs02CntlineDfrmTimCnt table |
| 1.3.6.1.4.1.20044.90.4.3.195.1.1 | Columnpm200frs02CntlineDfrmTimCntIndex | read-only | current | Index definition for the pm200frs02CntlineDfrmTimCnt table |
| 1.3.6.1.4.1.20044.90.4.3.195.1.2 | Columnpm200frs02CntlineDfrmTimCntValuePortn | read-only | current | Line Timer Counter : |
| 1.3.6.1.4.1.20044.90.4.3.195.1.3 | Columnpm200frs02CntlineDfrmTimCntErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.90.4.3.195.1.4 | Columnpm200frs02CntlineDfrmTimCntOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.90.4.3.196 | Tablepm200frs02CntlocalLineTrscvPreSdFecErrorCounterTable | not-accessible | current | List of pm200frs02CntlocalLineTrscvPreSdFecErrorCounter Article |
| 1.3.6.1.4.1.20044.90.4.3.196.1 | Rowpm200frs02CntlocalLineTrscvPreSdFecErrorCounterEntry | not-accessible | current | Row definition for the pm200frs02CntlocalLineTrscvPreSdFecErrorCounter table |
| 1.3.6.1.4.1.20044.90.4.3.196.1.1 | Columnpm200frs02CntlocalLineTrscvPreSdFecErrorCounterIndex | read-only | current | Index definition for the pm200frs02CntlocalLineTrscvPreSdFecErrorCounter table |
| 1.3.6.1.4.1.20044.90.4.3.196.1.2 | Columnpm200frs02CntlocalLineTrscvPreSdFecErrorCounterValuePortn | read-only | current | Pre FEC Errors :This OID gives the current Bit Error Rate before the FEC <Help> This counter gives the current Bit Error Rate before the FEC |
| 1.3.6.1.4.1.20044.90.4.3.196.1.3 | Columnpm200frs02CntlocalLineTrscvPreSdFecErrorCounterErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.90.4.3.196.1.4 | Columnpm200frs02CntlocalLineTrscvPreSdFecErrorCounterOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.90.4.3.197 | Tablepm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounterTable | not-accessible | current | List of pm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounter Article |
| 1.3.6.1.4.1.20044.90.4.3.197.1 | Rowpm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounterEntry | not-accessible | current | Row definition for the pm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounter table |
| 1.3.6.1.4.1.20044.90.4.3.197.1.1 | Columnpm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounterIndex | read-only | current | Index definition for the pm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounter table |
| 1.3.6.1.4.1.20044.90.4.3.197.1.2 | Columnpm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounterValuePortn | read-only | current | Uncorrected FEC Errors :This OID gives the current Bit Error Rate after the Soft Decision FEC (residual) <Help> This counter gives the current Bit Error Rate a… |
| 1.3.6.1.4.1.20044.90.4.3.197.1.3 | Columnpm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounterErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.90.4.3.197.1.4 | Columnpm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounterOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.90.4.3.198 | Tablepm200frs02CntlocalLineTrscvPreSdFecBitCounterTable | not-accessible | current | List of pm200frs02CntlocalLineTrscvPreSdFecBitCounter Article |
| 1.3.6.1.4.1.20044.90.4.3.198.1 | Rowpm200frs02CntlocalLineTrscvPreSdFecBitCounterEntry | not-accessible | current | Row definition for the pm200frs02CntlocalLineTrscvPreSdFecBitCounter table |
| 1.3.6.1.4.1.20044.90.4.3.198.1.1 | Columnpm200frs02CntlocalLineTrscvPreSdFecBitCounterIndex | read-only | current | Index definition for the pm200frs02CntlocalLineTrscvPreSdFecBitCounter table |
| 1.3.6.1.4.1.20044.90.4.3.198.1.2 | Columnpm200frs02CntlocalLineTrscvPreSdFecBitCounterValuePortn | read-only | current | Pre-SD FEC Bit Counter :This OID gives the current Bit count before the Soft Decision FEC <Help> This counter gives the current Bit Count before the Soft Decis… |
| 1.3.6.1.4.1.20044.90.4.3.198.1.3 | Columnpm200frs02CntlocalLineTrscvPreSdFecBitCounterErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.90.4.3.198.1.4 | Columnpm200frs02CntlocalLineTrscvPreSdFecBitCounterOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.90.4.3.199 | Tablepm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounterTable | not-accessible | current | List of pm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounter Article |
| 1.3.6.1.4.1.20044.90.4.3.199.1 | Rowpm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounterEntry | not-accessible | current | Row definition for the pm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounter table |
| 1.3.6.1.4.1.20044.90.4.3.199.1.1 | Columnpm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounterIndex | read-only | current | Index definition for the pm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounter table |
| 1.3.6.1.4.1.20044.90.4.3.199.1.2 | Columnpm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounterValuePortn | read-only | current | Uncorrected SD FEC Bit Counter :This OID gives the current Bit count after the Soft Decision FEC (residual) <Help> This counter gives the current Bit Count aft… |
| 1.3.6.1.4.1.20044.90.4.3.199.1.3 | Columnpm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounterErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.90.4.3.199.1.4 | Columnpm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounterOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.90.6 | Nodepm200frs02controlsWrite | |||
| 1.3.6.1.4.1.20044.90.6.1 | Nodepm200frs02CtrlOther | |||
| 1.3.6.1.4.1.20044.90.6.1.1 | Nodepm200frs02CtrlconfMgnt1 | |||
| 1.3.6.1.4.1.20044.90.6.1.1.1 | Scalarpm200frs02CtrlConf1Load1 | read-write | current | Load Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM. |
| 1.3.6.1.4.1.20044.90.6.1.1.2 | Scalarpm200frs02CtrlConf2Load1 | read-write | current | Load Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM. |
| 1.3.6.1.4.1.20044.90.6.1.1.10 | Scalarpm200frs02CtrlConf2Flash1 | read-write | current | Write Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura… |
| 1.3.6.1.4.1.20044.90.6.1.1.14 | Scalarpm200frs02CtrlConf2Clear1 | read-write | current | Clear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o… |
| 1.3.6.1.4.1.20044.90.6.1.4 | Nodepm200frs02Ctrlsynth4 | |||
| 1.3.6.1.4.1.20044.90.6.1.4.1 | Scalarpm200frs02CtrlCorrelatOn | read-write | current | Enable Alarm Correlation :This OID enables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.90.6.1.4.2 | Scalarpm200frs02CtrlCorrelatOff | read-write | current | Disable Alarm Correlation :This OID disables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.90.6.1.5 | Nodepm200frs02CtrlswMgnt | |||
| 1.3.6.1.4.1.20044.90.6.1.5.2 | Scalarpm200frs02CtrlColdReset | read-write | current | PM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> … |
| 1.3.6.1.4.1.20044.90.6.1.5.3 | Scalarpm200frs02CtrlWarmReset | read-write | current | PM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th… |
| 1.3.6.1.4.1.20044.90.6.1.5.5 | Scalarpm200frs02CtrlLoadSwBank1 | read-write | current | Set Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW… |
| 1.3.6.1.4.1.20044.90.6.1.5.6 | Scalarpm200frs02CtrlLoadSwBank2 | read-write | current | Set Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S… |
| 1.3.6.1.4.1.20044.90.6.1.6 | Nodepm200frs02CtrlgwMgnt | |||
| 1.3.6.1.4.1.20044.90.6.1.6.1 | Scalarpm200frs02CtrlCurrentGwReset | read-write | current | Active Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting. |
| 1.3.6.1.4.1.20044.90.6.1.6.5 | Scalarpm200frs02CtrlLoadGwBank1 | read-write | current | Set Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.90.6.1.6.6 | Scalarpm200frs02CtrlLoadGwBank2 | read-write | current | Set Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.90.6.1.6.7 | Scalarpm200frs02CtrlLoadGwBank3 | read-write | current | Set Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.90.6.1.6.8 | Scalarpm200frs02CtrlLoadGwBank4 | read-write | current | Set Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.90.6.1.192 | Nodepm200frs02CtrlledTest | |||
| 1.3.6.1.4.1.20044.90.6.1.192.1 | Scalarpm200frs02CtrlGreenLed | read-write | current | Green Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green |
| 1.3.6.1.4.1.20044.90.6.1.192.2 | Scalarpm200frs02CtrlRedLed | read-write | current | Red Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red |
| 1.3.6.1.4.1.20044.90.6.1.192.3 | Scalarpm200frs02CtrlLedOff | read-write | current | Leds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF |
| 1.3.6.1.4.1.20044.90.6.1.201 | Nodepm200frs02CtrlinitSwitchMarvell | |||
| 1.3.6.1.4.1.20044.90.6.1.201.1 | Scalarpm200frs02CtrlInitSwitchMarvell | read-write | current | Switch Initialization :This OID operates an initialization of the switch managed through the module <Help> This control activates an initialization of the swit… |
| 1.3.6.1.4.1.20044.90.6.1.259 | Nodepm200frs02CtrlresetCount | |||
| 1.3.6.1.4.1.20044.90.6.1.259.1 | Scalarpm200frs02CtrlResetcount | read-write | current | Module Count Global Reset :This OID resets all the errors counters on the module <Help > This control initiates a reset of the errors counters on the module |
| 1.3.6.1.4.1.20044.90.6.1.260 | Nodepm200frs02CtrlresetRmon | |||
| 1.3.6.1.4.1.20044.90.6.1.260.1 | Scalarpm200frs02CtrlResetrmon | read-write | current | Module Rmon Global Reset :This OID resets all the Rmon counters on the module <Help > This control initiates a reset of the Rmon counters on the module |
| 1.3.6.1.4.1.20044.90.6.1.261 | Nodepm200frs02CtrlresetMeasurements | |||
| 1.3.6.1.4.1.20044.90.6.1.261.1 | Scalarpm200frs02CtrlResetmeasurements | read-write | current | Management Meas Global Reset :This OID resets some measurements on the management <Help > This control initiates a reset of some measurements on the management |
| 1.3.6.1.4.1.20044.90.6.2 | Nodepm200frs02CtrlClient | |||
| 1.3.6.1.4.1.20044.90.6.2.16 | Tablepm200frs02CtrlaccessLoopTable | not-accessible | current | List of pm200frs02CtrlaccessLoop Article |
| 1.3.6.1.4.1.20044.90.6.2.16.1 | Rowpm200frs02CtrlaccessLoopEntry | not-accessible | current | Row definition for the pm200frs02CtrlaccessLoop table |
| 1.3.6.1.4.1.20044.90.6.2.16.1.1 | Columnpm200frs02CtrlaccessLoopIndex | read-only | current | Index definition for the pm200frs02CtrlaccessLoop table |
| 1.3.6.1.4.1.20044.90.6.2.16.1.2 | Columnpm200frs02CtrlaccessLoopPortn | read-write | current | Client Facility Loopback :This OID, when set at '1' puts the client port in loopback, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. <Help… |
| 1.3.6.1.4.1.20044.90.6.2.17 | Tablepm200frs02CtrlclientLoopToLineTable | not-accessible | current | List of pm200frs02CtrlclientLoopToLine Article |
| 1.3.6.1.4.1.20044.90.6.2.17.1 | Rowpm200frs02CtrlclientLoopToLineEntry | not-accessible | current | Row definition for the pm200frs02CtrlclientLoopToLine table |
| 1.3.6.1.4.1.20044.90.6.2.17.1.1 | Columnpm200frs02CtrlclientLoopToLineIndex | read-only | current | Index definition for the pm200frs02CtrlclientLoopToLine table |
| 1.3.6.1.4.1.20044.90.6.2.17.1.2 | Columnpm200frs02CtrlclientLoopToLinePortn | read-write | current | Client Terminal Loopback :This OID, when set, puts the client port in loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.<Help> This control ena… |
| 1.3.6.1.4.1.20044.90.6.2.21 | Tablepm200frs02CtrlcsfUpInsTable | not-accessible | current | List of pm200frs02CtrlcsfUpIns Article |
| 1.3.6.1.4.1.20044.90.6.2.21.1 | Rowpm200frs02CtrlcsfUpInsEntry | not-accessible | current | Row definition for the pm200frs02CtrlcsfUpIns table |
| 1.3.6.1.4.1.20044.90.6.2.21.1.1 | Columnpm200frs02CtrlcsfUpInsIndex | read-only | current | Index definition for the pm200frs02CtrlcsfUpIns table |
| 1.3.6.1.4.1.20044.90.6.2.21.1.2 | Columnpm200frs02CtrlcsfUpInsPortn | read-write | current | Client Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo… |
| 1.3.6.1.4.1.20044.90.6.2.22 | Tablepm200frs02CtrlcaisDwInsTable | not-accessible | current | List of pm200frs02CtrlcaisDwIns Article |
| 1.3.6.1.4.1.20044.90.6.2.22.1 | Rowpm200frs02CtrlcaisDwInsEntry | not-accessible | current | Row definition for the pm200frs02CtrlcaisDwIns table |
| 1.3.6.1.4.1.20044.90.6.2.22.1.1 | Columnpm200frs02CtrlcaisDwInsIndex | read-only | current | Index definition for the pm200frs02CtrlcaisDwIns table |
| 1.3.6.1.4.1.20044.90.6.2.22.1.2 | Columnpm200frs02CtrlcaisDwInsPortn | read-write | current | Client AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port |
| 1.3.6.1.4.1.20044.90.6.2.262 | Tablepm200frs02CtrlclientResetAllCountTable | not-accessible | current | List of pm200frs02CtrlclientResetAllCount Article |
| 1.3.6.1.4.1.20044.90.6.2.262.1 | Rowpm200frs02CtrlclientResetAllCountEntry | not-accessible | current | Row definition for the pm200frs02CtrlclientResetAllCount table |
| 1.3.6.1.4.1.20044.90.6.2.262.1.1 | Columnpm200frs02CtrlclientResetAllCountIndex | read-only | current | Index definition for the pm200frs02CtrlclientResetAllCount table |
| 1.3.6.1.4.1.20044.90.6.2.262.1.2 | Columnpm200frs02CtrlclientResetAllCountsPortn | read-write | current | Client Counters Reset :This OID resets every counter on the client port <Help> This control operates a reset on the statistics current ,previous and history cl… |
| 1.3.6.1.4.1.20044.90.6.3 | Nodepm200frs02CtrlLine | |||
| 1.3.6.1.4.1.20044.90.6.3.64 | Tablepm200frs02CtrlcommAccessLoopTable | not-accessible | current | List of pm200frs02CtrlcommAccessLoop Article |
| 1.3.6.1.4.1.20044.90.6.3.64.1 | Rowpm200frs02CtrlcommAccessLoopEntry | not-accessible | current | Row definition for the pm200frs02CtrlcommAccessLoop table |
| 1.3.6.1.4.1.20044.90.6.3.64.1.1 | Columnpm200frs02CtrlcommAccessLoopIndex | read-only | current | Index definition for the pm200frs02CtrlcommAccessLoop table |
| 1.3.6.1.4.1.20044.90.6.3.64.1.2 | Columnpm200frs02CtrlcommAccessLoopPortn | read-write | current | Line Terminal Loopback :This OID, when set, puts the module in common access loop back, looping the 200 Gb/s output signal on the 200 Gb/s input.<Help> This co… |
| 1.3.6.1.4.1.20044.90.6.3.66 | Tablepm200frs02CtrllineLoopTable | not-accessible | current | List of pm200frs02CtrllineLoop Article |
| 1.3.6.1.4.1.20044.90.6.3.66.1 | Rowpm200frs02CtrllineLoopEntry | not-accessible | current | Row definition for the pm200frs02CtrllineLoop table |
| 1.3.6.1.4.1.20044.90.6.3.66.1.1 | Columnpm200frs02CtrllineLoopIndex | read-only | current | Index definition for the pm200frs02CtrllineLoop table |
| 1.3.6.1.4.1.20044.90.6.3.66.1.2 | Columnpm200frs02CtrllineLoopPortn | read-write | current | Line Facility Loopback :This OID, when set at '1' puts the module in line loopback mode, looping the received 200 Gb/s signal on the transmit 200 Gb/s output. … |
| 1.3.6.1.4.1.20044.90.6.3.69 | Tablepm200frs02CtrlfecDisableTable | not-accessible | current | List of pm200frs02CtrlfecDisable Article |
| 1.3.6.1.4.1.20044.90.6.3.69.1 | Rowpm200frs02CtrlfecDisableEntry | not-accessible | current | Row definition for the pm200frs02CtrlfecDisable table |
| 1.3.6.1.4.1.20044.90.6.3.69.1.1 | Columnpm200frs02CtrlfecDisableIndex | read-only | current | Index definition for the pm200frs02CtrlfecDisable table |
| 1.3.6.1.4.1.20044.90.6.3.69.1.2 | Columnpm200frs02CtrlfecDisablePortn | read-write | current | Forward Error Correction Inhibition :This OID, when set, inhibits the Forward Error Correction feature on the line input <Help> This control enables/disables t… |
| 1.3.6.1.4.1.20044.90.6.3.209 | Tablepm200frs02CtrlmsaLineLoopTable | not-accessible | current | List of pm200frs02CtrlmsaLineLoop Article |
| 1.3.6.1.4.1.20044.90.6.3.209.1 | Rowpm200frs02CtrlmsaLineLoopEntry | not-accessible | current | Row definition for the pm200frs02CtrlmsaLineLoop table |
| 1.3.6.1.4.1.20044.90.6.3.209.1.1 | Columnpm200frs02CtrlmsaLineLoopIndex | read-only | current | Index definition for the pm200frs02CtrlmsaLineLoop table |
| 1.3.6.1.4.1.20044.90.6.3.209.1.2 | Columnpm200frs02CtrlmsaLineLoopPortn | read-write | current | MSA Line Loop :This OID operates a line loopback on the MSA Line <Help> This control defines the line loop back of the line transceiver |
| 1.3.6.1.4.1.20044.90.6.3.210 | Tablepm200frs02CtrlmsaTxResetTable | not-accessible | current | List of pm200frs02CtrlmsaTxReset Article |
| 1.3.6.1.4.1.20044.90.6.3.210.1 | Rowpm200frs02CtrlmsaTxResetEntry | not-accessible | current | Row definition for the pm200frs02CtrlmsaTxReset table |
| 1.3.6.1.4.1.20044.90.6.3.210.1.1 | Columnpm200frs02CtrlmsaTxResetIndex | read-only | current | Index definition for the pm200frs02CtrlmsaTxReset table |
| 1.3.6.1.4.1.20044.90.6.3.210.1.2 | Columnpm200frs02CtrlmsaTxResetPortn | read-write | current | Line MSA TX Reset :This OID resets the TX portion of the MSA line module <Help > This control initiates a reset of the transmitting side |
| 1.3.6.1.4.1.20044.90.6.3.211 | Tablepm200frs02CtrlmsaRxResetTable | not-accessible | current | List of pm200frs02CtrlmsaRxReset Article |
| 1.3.6.1.4.1.20044.90.6.3.211.1 | Rowpm200frs02CtrlmsaRxResetEntry | not-accessible | current | Row definition for the pm200frs02CtrlmsaRxReset table |
| 1.3.6.1.4.1.20044.90.6.3.211.1.1 | Columnpm200frs02CtrlmsaRxResetIndex | read-only | current | Index definition for the pm200frs02CtrlmsaRxReset table |
| 1.3.6.1.4.1.20044.90.6.3.211.1.2 | Columnpm200frs02CtrlmsaRxResetPortn | read-write | current | Line MSA RX Reset :This OID resets the RX portion of the MSA line module <Help > This control initiates a reset of the receiving side |
| 1.3.6.1.4.1.20044.90.6.3.212 | Tablepm200frs02CtrlmsaShutdownTable | not-accessible | current | List of pm200frs02CtrlmsaShutdown Article |
| 1.3.6.1.4.1.20044.90.6.3.212.1 | Rowpm200frs02CtrlmsaShutdownEntry | not-accessible | current | Row definition for the pm200frs02CtrlmsaShutdown table |
| 1.3.6.1.4.1.20044.90.6.3.212.1.1 | Columnpm200frs02CtrlmsaShutdownIndex | read-only | current | Index definition for the pm200frs02CtrlmsaShutdown table |
| 1.3.6.1.4.1.20044.90.6.3.212.1.2 | Columnpm200frs02CtrlmsaShutdownPortn | read-write | current | Line MSA Shutdown :This OID enters a process to shutdown the MSA line module <Help > This control initiates a shutdown of the module |
| 1.3.6.1.4.1.20044.90.6.3.263 | Tablepm200frs02CtrllineResetAllCountTable | not-accessible | current | List of pm200frs02CtrllineResetAllCount Article |
| 1.3.6.1.4.1.20044.90.6.3.263.1 | Rowpm200frs02CtrllineResetAllCountEntry | not-accessible | current | Row definition for the pm200frs02CtrllineResetAllCount table |
| 1.3.6.1.4.1.20044.90.6.3.263.1.1 | Columnpm200frs02CtrllineResetAllCountIndex | read-only | current | Index definition for the pm200frs02CtrllineResetAllCount table |
| 1.3.6.1.4.1.20044.90.6.3.263.1.2 | Columnpm200frs02CtrllineResetAllCountsPortn | read-write | current | Line Counters Reset :This OID resets every counter on the line port <Help> This control operates a reset on the statistics current ,previous and history line p… |
| 1.3.6.1.4.1.20044.90.7 | Nodepm200frs02ri | |||
| 1.3.6.1.4.1.20044.90.7.1 | Nodepm200frs02riTable | |||
| 1.3.6.1.4.1.20044.90.7.1.1 | Tablepm200frs02RinvSfpTable | not-accessible | current | List of the SFPs on the selected module |
| 1.3.6.1.4.1.20044.90.7.1.1.1 | Rowpm200frs02RinvSfpEntry | not-accessible | current | Row definition for the SFP table |
| 1.3.6.1.4.1.20044.90.7.1.1.1.1 | Columnpm200frs02RinvSfpIndex | read-only | current | Index for SFP table |
| 1.3.6.1.4.1.20044.90.7.1.1.1.2 | Columnpm200frs02Rinvsfp | read-only | current | Inventory for the SFP: This OID contains the inventory for the SFP |
| 1.3.6.1.4.1.20044.90.7.1.2 | Tablepm200frs02RinvLineTable | not-accessible | current | List of the XFPs on the selected module |
| 1.3.6.1.4.1.20044.90.7.1.2.1 | Rowpm200frs02RinvLineEntry | not-accessible | current | Row definition for the XFP table |
| 1.3.6.1.4.1.20044.90.7.1.2.1.1 | Columnpm200frs02RinvLineIndex | read-only | current | Index for XFP table |
| 1.3.6.1.4.1.20044.90.7.1.2.1.2 | Columnpm200frs02RinvxfpLine | read-only | current | Inventory for the XFP: This OID contains the inventory for the XFP |
| 1.3.6.1.4.1.20044.90.7.2 | Scalarpm200frs02RinvReloadInventory | read-write | current | Reload the inventory: This OID triggers an inventory reload. |
| 1.3.6.1.4.1.20044.90.7.3 | Scalarpm200frs02RinvHwPlatform | read-only | current | HW platform description: This OID contains the description of the Hardware platform. |
| 1.3.6.1.4.1.20044.90.7.4 | Scalarpm200frs02RinvModulePlatform | read-only | current | Module platform description: This OID contains the description of the Module. |
| 1.3.6.1.4.1.20044.90.7.5 | Scalarpm200frs02RinvSwPlatform | read-only | current | SW platform description: This OID contains the description of the Software platform. |
| 1.3.6.1.4.1.20044.90.7.6 | Scalarpm200frs02RinvGwPlatform | read-only | current | GW platform description: This OID contains the description of the Gateware platform. |
| 1.3.6.1.4.1.20044.90.8 | Nodepm200frs02download | |||
| 1.3.6.1.4.1.20044.90.8.1 | Nodepm200frs02DwlOther | |||
| 1.3.6.1.4.1.20044.90.8.1.0 | Nodepm200frs02DwlrestartProcess | |||
| 1.3.6.1.4.1.20044.90.8.1.0.1 | Scalarpm200frs02DwlWarmRestartProcessed | read-only | current | Warm Restart :This OID indicates that the module last restart was a Warm RESTART |
| 1.3.6.1.4.1.20044.90.8.1.0.2 | Scalarpm200frs02DwlColdRestartProcessed | read-only | current | Cold Restart :This OID indicates that the module last restart was a Cold RESTART |
| 1.3.6.1.4.1.20044.90.8.1.1 | Nodepm200frs02DwlswBanksUsed | |||
| 1.3.6.1.4.1.20044.90.8.1.1.1 | Scalarpm200frs02DwlSwBank1Used | read-only | current | SW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.90.8.1.1.2 | Scalarpm200frs02DwlSwBank2Used | read-only | current | SW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby |
| 1.3.6.1.4.1.20044.90.8.1.1.5 | Scalarpm200frs02DwlSwBank1Notempty | read-only | current | SW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package |
| 1.3.6.1.4.1.20044.90.8.1.1.6 | Scalarpm200frs02DwlSwBank2Notempty | read-only | current | SW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package |
| 1.3.6.1.4.1.20044.90.8.1.2 | Nodepm200frs02DwlgwBanksUsed | |||
| 1.3.6.1.4.1.20044.90.8.1.2.1 | Scalarpm200frs02DwlGwBank1Used | read-only | current | GW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.90.8.1.2.2 | Scalarpm200frs02DwlGwBank2Used | read-only | current | GW bank 2 active :This OID indicates the module is working on GW bank 2 |
| 1.3.6.1.4.1.20044.90.8.1.2.3 | Scalarpm200frs02DwlGwBank3Used | read-only | current | GW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby |
| 1.3.6.1.4.1.20044.90.8.1.2.4 | Scalarpm200frs02DwlGwBank4Used | read-only | current | GW bank 4 active :This OID indicates the module is working on GW bank 4 |
| 1.3.6.1.4.1.20044.90.8.1.2.5 | Scalarpm200frs02DwlGwBank1Notempty | read-only | current | GW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package |
| 1.3.6.1.4.1.20044.90.8.1.2.6 | Scalarpm200frs02DwlGwBank2Notempty | read-only | current | GW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2 |
| 1.3.6.1.4.1.20044.90.8.1.2.7 | Scalarpm200frs02DwlGwBank3Notempty | read-only | current | GW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package |
| 1.3.6.1.4.1.20044.90.8.1.2.8 | Scalarpm200frs02DwlGwBank4Notempty | read-only | current | GW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4 |
| 1.3.6.1.4.1.20044.90.8.2 | Nodepm200frs02DwlClient | |||
| 1.3.6.1.4.1.20044.90.8.3 | Nodepm200frs02DwlLine | |||
| 1.3.6.1.4.1.20044.90.9 | Nodepm200frs02Config | |||
| 1.3.6.1.4.1.20044.90.9.1 | Nodepm200frs02CfgAccessCAisCsf | |||
| 1.3.6.1.4.1.20044.90.9.1.1 | Tablepm200frs02CfgClientcaiscsfTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.90.9.1.1.1 | Rowpm200frs02CfgClientcaiscsfEntry | not-accessible | current | Row definition for the accessCAisCsf table |
| 1.3.6.1.4.1.20044.90.9.1.1.1.1 | Columnpm200frs02CfgClientcaiscsfIndex | read-only | current | Index definition for the clientcaiscsf table |
| 1.3.6.1.4.1.20044.90.9.1.1.1.3 | Columnpm200frs02CfgReservePortn | read-write | current | CAIS mode on Client Port :This register enables/disables port laser shutdown on CAIS insertion condition |
| 1.3.6.1.4.1.20044.90.9.2 | Nodepm200frs02CfgStartup | |||
| 1.3.6.1.4.1.20044.90.9.2.1 | Tablepm200frs02CfgClientStartupTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.90.9.2.1.1 | Rowpm200frs02CfgClientStartupEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.90.9.2.1.1.1 | Columnpm200frs02CfgClientStartupIndex | read-only | current | Index definition for the clientStartup table |
| 1.3.6.1.4.1.20044.90.9.2.1.1.3 | Columnpm200frs02CfgSystConfPortPortn | read-write | current | Default Settings on Client Port :This register configures the default initialisation settings on the port. |
| 1.3.6.1.4.1.20044.90.9.2.1.1.4 | Columnpm200frs02CfgNetConfPortPortn | read-write | current | Default Settings on Client Port :This register configures the default initialisation settings on the port. |
| 1.3.6.1.4.1.20044.90.9.2.1.1.14 | Columnpm200frs02CfgOptionsPortPortn | read-write | current | Default Options on Client Port :This register configures the default options on the port. |
| 1.3.6.1.4.1.20044.90.9.2.2 | Tablepm200frs02CfgLineStartupTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.90.9.2.2.1 | Rowpm200frs02CfgLineStartupEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.90.9.2.2.1.1 | Columnpm200frs02CfgLineStartupIndex | read-only | current | Index definition for the lineStartup table |
| 1.3.6.1.4.1.20044.90.9.2.2.1.3 | Columnpm200frs02CfgSystConfLinePortn | read-write | current | Default Settings on Line :This register configures the default initialisation settings on Line |
| 1.3.6.1.4.1.20044.90.9.2.2.1.14 | Columnpm200frs02CfgOptionsLinePortn | read-write | current | Default Options on Line :This register configures the default options on the line |
| 1.3.6.1.4.1.20044.90.9.2.3 | Tablepm200frs02CfgXfpTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.90.9.2.3.1 | Rowpm200frs02CfgXfpEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.90.9.2.3.1.1 | Columnpm200frs02CfgXfpIndex | read-only | current | Index definition for the xfp table |
| 1.3.6.1.4.1.20044.90.9.2.3.1.3 | Columnpm200frs02CfgSystConfMsaLinePortn | read-write | current | Default settings on MSA :This register configures the default initialisation settings on MSA |
| 1.3.6.1.4.1.20044.90.9.3 | Nodepm200frs02CfgLabels | |||
| 1.3.6.1.4.1.20044.90.9.3.1 | Tablepm200frs02CfgLabelclientTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.90.9.3.1.1 | Rowpm200frs02CfgLabelclientEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.90.9.3.1.1.1 | Columnpm200frs02CfgLabelclientIndex | read-only | current | Index definition for the labelclient table |
| 1.3.6.1.4.1.20044.90.9.3.1.1.3 | Columnpm200frs02CfgLabelclientPortn | read-write | current | Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. |
| 1.3.6.1.4.1.20044.90.9.3.2 | Tablepm200frs02CfgLabellineTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.90.9.3.2.1 | Rowpm200frs02CfgLabellineEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.90.9.3.2.1.1 | Columnpm200frs02CfgLabellineIndex | read-only | current | Index definition for the labelline table |
| 1.3.6.1.4.1.20044.90.9.3.2.1.3 | Columnpm200frs02CfgLabellinePortn | read-write | current | Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. |
| 1.3.6.1.4.1.20044.90.9.4 | Nodepm200frs02CfgStartuptlh | |||
| 1.3.6.1.4.1.20044.90.9.4.1 | Tablepm200frs02CfgOtxtlhTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.90.9.4.1.1 | Rowpm200frs02CfgOtxtlhEntry | not-accessible | current | Row definition for the startuptlh table |
| 1.3.6.1.4.1.20044.90.9.4.1.1.1 | Columnpm200frs02CfgOtxtlhIndex | read-only | current | Index definition for the otxtlh table |
| 1.3.6.1.4.1.20044.90.9.4.1.1.6 | Columnpm200frs02CfgLinePwrLaserPortn | read-write | current | Defaut Line output Power :This register configures the start-up output power of the Line tranceiver (Unit = dBm) |
| 1.3.6.1.4.1.20044.90.9.4.1.1.7 | Columnpm200frs02CfgLineFCurrentPortn | read-write | current | Default Line transceiver Tx Channel :This register configures the start-up laser channel of the Line Tx transceiver |
| 1.3.6.1.4.1.20044.90.9.4.1.1.8 | Columnpm200frs02CfgLineGridCurrentPortn | read-write | current | Default Line transceiver Grid :This register configures the start-up laser grid of the Line transceiver |
| 1.3.6.1.4.1.20044.90.9.4.1.1.9 | Columnpm200frs02CfgFPortn | read-write | current | Default Line TRX lowest Freq :This register configures the start-up lowest frequency of the Line transceiver |
| 1.3.6.1.4.1.20044.90.9.4.1.1.10 | Columnpm200frs02CfgRxLineFCurrentPortn | read-write | current | Default Line transceiver Rx Channel :This register configures the start-up laser channel of the Line Rx transceiver |
| 1.3.6.1.4.1.20044.90.9.5 | Nodepm200frs02CfgOther | |||
| 1.3.6.1.4.1.20044.90.9.5.1 | Nodepm200frs02tablemoduleOther | |||
| 1.3.6.1.4.1.20044.90.9.5.1.2 | Scalarpm200frs02Cfgmode | read-write | current | Default settings on Module :This register selects the configuration mode of the module |
| 1.3.6.1.4.1.20044.90.9.5.1.3 | Scalarpm200frs02CfgfanLowSpeedThreshold | read-write | current | Default settings on Module :This register selects the speed threshold of the fan's |
| 1.3.6.1.4.1.20044.90.9.5.1.4 | Scalarpm200frs02CfgfanHighSpeedThreshold | read-write | current | Default settings on Module :This register selects the speed threshold of the fan's |
| 1.3.6.1.4.1.20044.90.9.5.1.5 | Scalarpm200frs02CfgmoduleMode | read-write | current | Default settings on Module :This register selects the configuration mode of the module |
| 1.3.6.1.4.1.20044.90.9.6 | Nodepm200frs02CfgStartuptablefive | |||
| 1.3.6.1.4.1.20044.90.9.6.1 | Tablepm200frs02CfgOtxtlhcapabilitiesTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.90.9.6.1.1 | Rowpm200frs02CfgOtxtlhcapabilitiesEntry | not-accessible | current | Row definition for the startuptablefive table |
| 1.3.6.1.4.1.20044.90.9.6.1.1.1 | Columnpm200frs02CfgOtxtlhcapabilitiesIndex | read-only | current | Index definition for the otxtlhcapabilities table |
| 1.3.6.1.4.1.20044.90.9.6.1.1.3 | Columnpm200frs02CfgComponentTypePortn | read-only | current | Component parameters :This OID defines the component parameters |
| 1.3.6.1.4.1.20044.90.9.6.1.1.4 | Columnpm200frs02CfgMiscellaneousPortn | read-only | current | Miscellaneous default settings :This OID defines the miscellaneous parameters |
| 1.3.6.1.4.1.20044.90.9.6.1.1.5 | Columnpm200frs02CfgFirstChannelPortn | read-only | current | Number of the first channel of the component :This OID defines the first channel number of the PM |
| 1.3.6.1.4.1.20044.90.9.6.1.1.6 | Columnpm200frs02CfgLastChannelPortn | read-only | current | Number of the last channel of the component :This OID defines the last channel number of the PM |
| 1.3.6.1.4.1.20044.90.9.6.1.1.7 | Columnpm200frs02CfgGridPortn | read-only | current | Grid value of the component :This OID defines the grid of the PM |
| 1.3.6.1.4.1.20044.90.9.257 | Scalarpm200frs02CfgWriteConfiguration | read-write | current | Write configuration to module:This OID writes the complete configuration to the module |
| 1.3.6.1.4.1.20044.90.10 | Nodepm200frs02traps | |||
| 1.3.6.1.4.1.20044.90.10.2 | Scalarpm200frs02trapPortNumber | read-only | current | Last port which generates a trap |
| 1.3.6.1.4.1.20044.90.10.3 | Scalarpm200frs02trapLineNumber | read-only | current | Last Line which generates a trap |
| 1.3.6.1.4.1.20044.90.10.4 | Scalarpm200frs02trapBoardNumber | read-only | current | Last module which generates a trap |
| 1.3.6.1.4.1.20044.90.10.30 | Notificationpm200frs02LineTrapNotUrgentGoesOn | current | Not urgent Line default is activated | |
| 1.3.6.1.4.1.20044.90.10.31 | Notificationpm200frs02LineTrapNotUrgentGoesOff | current | Not urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.90.10.32 | Notificationpm200frs02LineTrapUrgentGoesOn | current | Urgent Line default is activated | |
| 1.3.6.1.4.1.20044.90.10.33 | Notificationpm200frs02LineTrapUrgentGoesOff | current | Urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.90.10.34 | Notificationpm200frs02LineTrapCritGoesOn | current | Critical Line default is activated | |
| 1.3.6.1.4.1.20044.90.10.35 | Notificationpm200frs02LineTrapCritGoesOff | current | Critical Line default disappeared | |
| 1.3.6.1.4.1.20044.90.10.40 | Notificationpm200frs02ClientTrapNotUrgentGoesOn | current | Not urgent client default is activated | |
| 1.3.6.1.4.1.20044.90.10.41 | Notificationpm200frs02ClientTrapNotUrgentGoesOff | current | Not urgent client default disappeared | |
| 1.3.6.1.4.1.20044.90.10.42 | Notificationpm200frs02ClientTrapUrgentGoesOn | current | Urgent client default is activated | |
| 1.3.6.1.4.1.20044.90.10.43 | Notificationpm200frs02ClientTrapUrgentGoesOff | current | Urgent client default disappeared | |
| 1.3.6.1.4.1.20044.90.10.44 | Notificationpm200frs02ClientTrapCritGoesOn | current | Critical client default is activated | |
| 1.3.6.1.4.1.20044.90.10.45 | Notificationpm200frs02ClientTrapCritGoesOff | current | Critical client default disappeared | |
| 1.3.6.1.4.1.20044.90.10.50 | Notificationpm200frs02PowerTrapUrgentGoesOn | current | Urgent power supply default is activated | |
| 1.3.6.1.4.1.20044.90.10.51 | Notificationpm200frs02PowerTrapUrgentGoesOff | current | Urgent power supply default disappeared | |
| 1.3.6.1.4.1.20044.90.11 | Nodepm200frs02Monitoring | |||
| 1.3.6.1.4.1.20044.90.11.1 | Nodepm200frs02MonOther | |||
| 1.3.6.1.4.1.20044.90.11.1.3 | Nodepm200frs02MonRmon | |||
| 1.3.6.1.4.1.20044.90.11.2 | Nodepm200frs02MonClient | |||
| 1.3.6.1.4.1.20044.90.11.2.4 | Nodepm200frs02MonClientRmonCounter | |||
| 1.3.6.1.4.1.20044.90.11.2.4.16 | Tablepm200frs02MonupRmonBytesCounterClientInputTable | not-accessible | current | List of pm200frs02MonupRmonBytesCounterClientInput Article |
| 1.3.6.1.4.1.20044.90.11.2.4.16.1 | Rowpm200frs02MonupRmonBytesCounterClientInputEntry | not-accessible | current | Row definition for the pm200frs02MonupRmonBytesCounterClientInput table |
| 1.3.6.1.4.1.20044.90.11.2.4.16.1.1 | Columnpm200frs02MonupRmonBytesCounterClientInputIndex | read-only | current | Index definition for the pm200frs02MonupRmonBytesCounterClientInput table |
| 1.3.6.1.4.1.20044.90.11.2.4.16.1.2 | Columnpm200frs02MonupRmonBytesCounterClientInputValuePortn | read-only | current | Client Input Bytes :This counter is increased each time a data byte is received on the client port <Help> This counter gives the number of bytes received on th… |
| 1.3.6.1.4.1.20044.90.11.2.4.16.1.3 | Columnpm200frs02MonupRmonBytesCounterClientInputErrorPortn | read-only | current | Bytes Counter Error :This OID when set indicates the Bytes counter value is invalid on client port |
| 1.3.6.1.4.1.20044.90.11.2.4.16.1.4 | Columnpm200frs02MonupRmonBytesCounterClientInputOverloadPortn | read-only | current | Bytes Counter Overload :This OID when set indicates a Bytes counter overload on client port |
| 1.3.6.1.4.1.20044.90.11.2.4.48 | Tablepm200frs02MonupRmonCrcErrorsCounterClientInputTable | not-accessible | current | List of pm200frs02MonupRmonCrcErrorsCounterClientInput Article |
| 1.3.6.1.4.1.20044.90.11.2.4.48.1 | Rowpm200frs02MonupRmonCrcErrorsCounterClientInputEntry | not-accessible | current | Row definition for the pm200frs02MonupRmonCrcErrorsCounterClientInput table |
| 1.3.6.1.4.1.20044.90.11.2.4.48.1.1 | Columnpm200frs02MonupRmonCrcErrorsCounterClientInputIndex | read-only | current | Index definition for the pm200frs02MonupRmonCrcErrorsCounterClientInput table |
| 1.3.6.1.4.1.20044.90.11.2.4.48.1.2 | Columnpm200frs02MonupRmonCrcErrorsCounterClientInputValuePortn | read-only | current | Client Input CRC Errors :This counter is increased each time a CRC error is detected on the client port<Help> This counter gives the number of CRC Errors recei… |
| 1.3.6.1.4.1.20044.90.11.2.4.48.1.3 | Columnpm200frs02MonupRmonCrcErrorsCounterClientInputErrorPortn | read-only | current | CRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on client port |
| 1.3.6.1.4.1.20044.90.11.2.4.48.1.4 | Columnpm200frs02MonupRmonCrcErrorsCounterClientInputOverloadPortn | read-only | current | CRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on client port |
| 1.3.6.1.4.1.20044.90.11.2.4.80 | Tablepm200frs02MonupRmonPacketsCounterClientInputTable | not-accessible | current | List of pm200frs02MonupRmonPacketsCounterClientInput Article |
| 1.3.6.1.4.1.20044.90.11.2.4.80.1 | Rowpm200frs02MonupRmonPacketsCounterClientInputEntry | not-accessible | current | Row definition for the pm200frs02MonupRmonPacketsCounterClientInput table |
| 1.3.6.1.4.1.20044.90.11.2.4.80.1.1 | Columnpm200frs02MonupRmonPacketsCounterClientInputIndex | read-only | current | Index definition for the pm200frs02MonupRmonPacketsCounterClientInput table |
| 1.3.6.1.4.1.20044.90.11.2.4.80.1.2 | Columnpm200frs02MonupRmonPacketsCounterClientInputValuePortn | read-only | current | Client Input Packets :This counter is increased each time a packet is received on the client port <Help> This counter gives the number of packets received on t… |
| 1.3.6.1.4.1.20044.90.11.2.4.80.1.3 | Columnpm200frs02MonupRmonPacketsCounterClientInputErrorPortn | read-only | current | Packets Counter Error :This OID when set indicates the Packets counter value is invalid on client port |
| 1.3.6.1.4.1.20044.90.11.2.4.80.1.4 | Columnpm200frs02MonupRmonPacketsCounterClientInputOverloadPortn | read-only | current | Packets Counter Overload :This OID when set indicates a Packets counter overload on client port |
| 1.3.6.1.4.1.20044.90.11.2.4.112 | Tablepm200frs02MonupRmonBroadcastCounterClientInputTable | not-accessible | current | List of pm200frs02MonupRmonBroadcastCounterClientInput Article |
| 1.3.6.1.4.1.20044.90.11.2.4.112.1 | Rowpm200frs02MonupRmonBroadcastCounterClientInputEntry | not-accessible | current | Row definition for the pm200frs02MonupRmonBroadcastCounterClientInput table |
| 1.3.6.1.4.1.20044.90.11.2.4.112.1.1 | Columnpm200frs02MonupRmonBroadcastCounterClientInputIndex | read-only | current | Index definition for the pm200frs02MonupRmonBroadcastCounterClientInput table |
| 1.3.6.1.4.1.20044.90.11.2.4.112.1.2 | Columnpm200frs02MonupRmonBroadcastCounterClientInputValuePortn | read-only | current | Client Input Broadcast Packets :This counter is increased each time a broadcast packet is received on the client port <Help> This counter gives the number of B… |
| 1.3.6.1.4.1.20044.90.11.2.4.112.1.3 | Columnpm200frs02MonupRmonBroadcastCounterClientInputErrorPortn | read-only | current | Broadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.90.11.2.4.112.1.4 | Columnpm200frs02MonupRmonBroadcastCounterClientInputOverloadPortn | read-only | current | Broadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port |
| 1.3.6.1.4.1.20044.90.11.2.4.144 | Tablepm200frs02MonupRmonMulticastCounterClientInputTable | not-accessible | current | List of pm200frs02MonupRmonMulticastCounterClientInput Article |
| 1.3.6.1.4.1.20044.90.11.2.4.144.1 | Rowpm200frs02MonupRmonMulticastCounterClientInputEntry | not-accessible | current | Row definition for the pm200frs02MonupRmonMulticastCounterClientInput table |
| 1.3.6.1.4.1.20044.90.11.2.4.144.1.1 | Columnpm200frs02MonupRmonMulticastCounterClientInputIndex | read-only | current | Index definition for the pm200frs02MonupRmonMulticastCounterClientInput table |
| 1.3.6.1.4.1.20044.90.11.2.4.144.1.2 | Columnpm200frs02MonupRmonMulticastCounterClientInputValuePortn | read-only | current | Client Input Multicast Packets :This counter is increased each time a Multicast packet is received on the client port <Help> This counter gives the number of M… |
| 1.3.6.1.4.1.20044.90.11.2.4.144.1.3 | Columnpm200frs02MonupRmonMulticastCounterClientInputErrorPortn | read-only | current | Multicast Counter Error :This OID when set indicates the Multicast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.90.11.2.4.144.1.4 | Columnpm200frs02MonupRmonMulticastCounterClientInputOverloadPortn | read-only | current | Multicast Counter Overload :This OID when set indicates a Multicast counter overload on client port |
| 1.3.6.1.4.1.20044.90.11.2.4.176 | Tablepm200frs02MonupRmonPauseFrameCounterClientInputTable | not-accessible | current | List of pm200frs02MonupRmonPauseFrameCounterClientInput Article |
| 1.3.6.1.4.1.20044.90.11.2.4.176.1 | Rowpm200frs02MonupRmonPauseFrameCounterClientInputEntry | not-accessible | current | Row definition for the pm200frs02MonupRmonPauseFrameCounterClientInput table |
| 1.3.6.1.4.1.20044.90.11.2.4.176.1.1 | Columnpm200frs02MonupRmonPauseFrameCounterClientInputIndex | read-only | current | Index definition for the pm200frs02MonupRmonPauseFrameCounterClientInput table |
| 1.3.6.1.4.1.20044.90.11.2.4.176.1.2 | Columnpm200frs02MonupRmonPauseFrameCounterClientInputValuePortn | read-only | current | Client Input Pause Frames :This counter is increased each time a Pause frame is received on the client port <Help> This counter gives the number of Pause frame… |
| 1.3.6.1.4.1.20044.90.11.2.4.176.1.3 | Columnpm200frs02MonupRmonPauseFrameCounterClientInputErrorPortn | read-only | current | Pause Counter Error :This OID when set indicates the Pause counter value is invalid on client port |
| 1.3.6.1.4.1.20044.90.11.2.4.176.1.4 | Columnpm200frs02MonupRmonPauseFrameCounterClientInputOverloadPortn | read-only | current | Pause Counter Overload :This OID when set indicates a Pause counter overload on client port |
| 1.3.6.1.4.1.20044.90.11.2.4.304 | Tablepm200frs02MonupRmonUnicastCounterClientInputTable | not-accessible | current | List of pm200frs02MonupRmonUnicastCounterClientInput Article |
| 1.3.6.1.4.1.20044.90.11.2.4.304.1 | Rowpm200frs02MonupRmonUnicastCounterClientInputEntry | not-accessible | current | Row definition for the pm200frs02MonupRmonUnicastCounterClientInput table |
| 1.3.6.1.4.1.20044.90.11.2.4.304.1.1 | Columnpm200frs02MonupRmonUnicastCounterClientInputIndex | read-only | current | Index definition for the pm200frs02MonupRmonUnicastCounterClientInput table |
| 1.3.6.1.4.1.20044.90.11.2.4.304.1.2 | Columnpm200frs02MonupRmonUnicastCounterClientInputValuePortn | read-only | current | Client Input Unicast Packets :This counter is increased each time a Unicast packet is received on the client port <Help> This counter gives the number of Unica… |
| 1.3.6.1.4.1.20044.90.11.2.4.304.1.3 | Columnpm200frs02MonupRmonUnicastCounterClientInputErrorPortn | read-only | current | Unicast Counter Error :This OID when set indicates the Unicast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.90.11.2.4.304.1.4 | Columnpm200frs02MonupRmonUnicastCounterClientInputOverloadPortn | read-only | current | Unicast Counter Overload :This OID when set indicates a Unicast counter overload on client port |
| 1.3.6.1.4.1.20044.90.11.2.4.336 | Tablepm200frs02MonupRmonNonunicastCounterClientInputTable | not-accessible | current | List of pm200frs02MonupRmonNonunicastCounterClientInput Article |
| 1.3.6.1.4.1.20044.90.11.2.4.336.1 | Rowpm200frs02MonupRmonNonunicastCounterClientInputEntry | not-accessible | current | Row definition for the pm200frs02MonupRmonNonunicastCounterClientInput table |
| 1.3.6.1.4.1.20044.90.11.2.4.336.1.1 | Columnpm200frs02MonupRmonNonunicastCounterClientInputIndex | read-only | current | Index definition for the pm200frs02MonupRmonNonunicastCounterClientInput table |
| 1.3.6.1.4.1.20044.90.11.2.4.336.1.2 | Columnpm200frs02MonupRmonNonunicastCounterClientInputValuePortn | read-only | current | Client Input Non Unicast Packets :This counter is increased each time a Non-Unicast packet is received on the client port <Help> This counter gives the number … |
| 1.3.6.1.4.1.20044.90.11.2.4.336.1.3 | Columnpm200frs02MonupRmonNonunicastCounterClientInputErrorPortn | read-only | current | Non Unicast Counter Error :This OID when set indicates the Non-Unicast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.90.11.2.4.336.1.4 | Columnpm200frs02MonupRmonNonunicastCounterClientInputOverloadPortn | read-only | current | Non Unicast Counter Overload :This OID when set indicates a Non-Unicast counter overload on client port |
| 1.3.6.1.4.1.20044.90.11.2.4.400 | Tablepm200frs02MondownRmonBytesCounterClientOutputTable | not-accessible | current | List of pm200frs02MondownRmonBytesCounterClientOutput Article |
| 1.3.6.1.4.1.20044.90.11.2.4.400.1 | Rowpm200frs02MondownRmonBytesCounterClientOutputEntry | not-accessible | current | Row definition for the pm200frs02MondownRmonBytesCounterClientOutput table |
| 1.3.6.1.4.1.20044.90.11.2.4.400.1.1 | Columnpm200frs02MondownRmonBytesCounterClientOutputIndex | read-only | current | Index definition for the pm200frs02MondownRmonBytesCounterClientOutput table |
| 1.3.6.1.4.1.20044.90.11.2.4.400.1.2 | Columnpm200frs02MondownRmonBytesCounterClientOutputValuePortn | read-only | current | Client Output Bytes :This counter is increased each time a data byte is transmitted on the client port <Help> This counter gives the number of bytes transmitte… |
| 1.3.6.1.4.1.20044.90.11.2.4.400.1.3 | Columnpm200frs02MondownRmonBytesCounterClientOutputErrorPortn | read-only | current | Bytes Counter Error :This OID when set indicates the Bytes counter value is invalid on client port |
| 1.3.6.1.4.1.20044.90.11.2.4.400.1.4 | Columnpm200frs02MondownRmonBytesCounterClientOutputOverloadPortn | read-only | current | Bytes Counter Overload :This OID when set indicates a Bytes counter overload on client port |
| 1.3.6.1.4.1.20044.90.11.2.4.432 | Tablepm200frs02MondownRmonCrcErrorsCounterClientOutputTable | not-accessible | current | List of pm200frs02MondownRmonCrcErrorsCounterClientOutput Article |
| 1.3.6.1.4.1.20044.90.11.2.4.432.1 | Rowpm200frs02MondownRmonCrcErrorsCounterClientOutputEntry | not-accessible | current | Row definition for the pm200frs02MondownRmonCrcErrorsCounterClientOutput table |
| 1.3.6.1.4.1.20044.90.11.2.4.432.1.1 | Columnpm200frs02MondownRmonCrcErrorsCounterClientOutputIndex | read-only | current | Index definition for the pm200frs02MondownRmonCrcErrorsCounterClientOutput table |
| 1.3.6.1.4.1.20044.90.11.2.4.432.1.2 | Columnpm200frs02MondownRmonCrcErrorsCounterClientOutputValuePortn | read-only | current | Client Output CRC Errors :This counter is increased each time a CRC error is detected on the transmit client port <Help> This counter gives the number of CRC E… |
| 1.3.6.1.4.1.20044.90.11.2.4.432.1.3 | Columnpm200frs02MondownRmonCrcErrorsCounterClientOutputErrorPortn | read-only | current | CRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on client port |
| 1.3.6.1.4.1.20044.90.11.2.4.432.1.4 | Columnpm200frs02MondownRmonCrcErrorsCounterClientOutputOverloadPortn | read-only | current | CRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on client port |
| 1.3.6.1.4.1.20044.90.11.2.4.464 | Tablepm200frs02MondownRmonPacketsCounterClientOutputTable | not-accessible | current | List of pm200frs02MondownRmonPacketsCounterClientOutput Article |
| 1.3.6.1.4.1.20044.90.11.2.4.464.1 | Rowpm200frs02MondownRmonPacketsCounterClientOutputEntry | not-accessible | current | Row definition for the pm200frs02MondownRmonPacketsCounterClientOutput table |
| 1.3.6.1.4.1.20044.90.11.2.4.464.1.1 | Columnpm200frs02MondownRmonPacketsCounterClientOutputIndex | read-only | current | Index definition for the pm200frs02MondownRmonPacketsCounterClientOutput table |
| 1.3.6.1.4.1.20044.90.11.2.4.464.1.2 | Columnpm200frs02MondownRmonPacketsCounterClientOutputValuePortn | read-only | current | Client Output Packets :This counter is increased each time a packet is transmitted on the client port <Help> This counter gives the number of packets transmitt… |
| 1.3.6.1.4.1.20044.90.11.2.4.464.1.3 | Columnpm200frs02MondownRmonPacketsCounterClientOutputErrorPortn | read-only | current | Packets Counter Error :This OID when set indicates the Packets counter value is invalid on client port |
| 1.3.6.1.4.1.20044.90.11.2.4.464.1.4 | Columnpm200frs02MondownRmonPacketsCounterClientOutputOverloadPortn | read-only | current | Packets Counter Overload :This OID when set indicates a Packets counter overload on client port |
| 1.3.6.1.4.1.20044.90.11.2.4.496 | Tablepm200frs02MondownRmonBroadcastCounterClientOutputTable | not-accessible | current | List of pm200frs02MondownRmonBroadcastCounterClientOutput Article |
| 1.3.6.1.4.1.20044.90.11.2.4.496.1 | Rowpm200frs02MondownRmonBroadcastCounterClientOutputEntry | not-accessible | current | Row definition for the pm200frs02MondownRmonBroadcastCounterClientOutput table |
| 1.3.6.1.4.1.20044.90.11.2.4.496.1.1 | Columnpm200frs02MondownRmonBroadcastCounterClientOutputIndex | read-only | current | Index definition for the pm200frs02MondownRmonBroadcastCounterClientOutput table |
| 1.3.6.1.4.1.20044.90.11.2.4.496.1.2 | Columnpm200frs02MondownRmonBroadcastCounterClientOutputValuePortn | read-only | current | Client Output Broadcast Packets :This counter is increased each time a broadcast packet is transmitted on the client port <Help> This counter gives the number … |
| 1.3.6.1.4.1.20044.90.11.2.4.496.1.3 | Columnpm200frs02MondownRmonBroadcastCounterClientOutputErrorPortn | read-only | current | Broadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.90.11.2.4.496.1.4 | Columnpm200frs02MondownRmonBroadcastCounterClientOutputOverloadPortn | read-only | current | Broadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port |
| 1.3.6.1.4.1.20044.90.11.2.4.528 | Tablepm200frs02MondownRmonMulticastCounterClientOutputTable | not-accessible | current | List of pm200frs02MondownRmonMulticastCounterClientOutput Article |
| 1.3.6.1.4.1.20044.90.11.2.4.528.1 | Rowpm200frs02MondownRmonMulticastCounterClientOutputEntry | not-accessible | current | Row definition for the pm200frs02MondownRmonMulticastCounterClientOutput table |
| 1.3.6.1.4.1.20044.90.11.2.4.528.1.1 | Columnpm200frs02MondownRmonMulticastCounterClientOutputIndex | read-only | current | Index definition for the pm200frs02MondownRmonMulticastCounterClientOutput table |
| 1.3.6.1.4.1.20044.90.11.2.4.528.1.2 | Columnpm200frs02MondownRmonMulticastCounterClientOutputValuePortn | read-only | current | Client Output Multicast Packets :This counter is increased each time a Multicast packet is transmitted on the client port <Help> This counter gives the number … |
| 1.3.6.1.4.1.20044.90.11.2.4.528.1.3 | Columnpm200frs02MondownRmonMulticastCounterClientOutputErrorPortn | read-only | current | Multicast Counter Error :This OID when set indicates the Multicast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.90.11.2.4.528.1.4 | Columnpm200frs02MondownRmonMulticastCounterClientOutputOverloadPortn | read-only | current | Multicast Counter Overload :This OID when set indicates a Multicast counter overload on client port |
| 1.3.6.1.4.1.20044.90.11.2.4.560 | Tablepm200frs02MondownRmonPauseFrameCounterClientOutputTable | not-accessible | current | List of pm200frs02MondownRmonPauseFrameCounterClientOutput Article |
| 1.3.6.1.4.1.20044.90.11.2.4.560.1 | Rowpm200frs02MondownRmonPauseFrameCounterClientOutputEntry | not-accessible | current | Row definition for the pm200frs02MondownRmonPauseFrameCounterClientOutput table |
| 1.3.6.1.4.1.20044.90.11.2.4.560.1.1 | Columnpm200frs02MondownRmonPauseFrameCounterClientOutputIndex | read-only | current | Index definition for the pm200frs02MondownRmonPauseFrameCounterClientOutput table |
| 1.3.6.1.4.1.20044.90.11.2.4.560.1.2 | Columnpm200frs02MondownRmonPauseFrameCounterClientOutputValuePortn | read-only | current | Client Output Pause Frames :This counter is increased each time a Pause frame is transmitted on the client port <Help> This counter gives the number of Pause f… |
| 1.3.6.1.4.1.20044.90.11.2.4.560.1.3 | Columnpm200frs02MondownRmonPauseFrameCounterClientOutputErrorPortn | read-only | current | Pause Counter Error :This OID when set indicates the Pause counter value is invalid on client port |
| 1.3.6.1.4.1.20044.90.11.2.4.560.1.4 | Columnpm200frs02MondownRmonPauseFrameCounterClientOutputOverloadPortn | read-only | current | Pause Counter Overload :This OID when set indicates a Pause counter overload on client port |
| 1.3.6.1.4.1.20044.90.11.2.4.688 | Tablepm200frs02MondownRmonUnicastCounterClientOutputTable | not-accessible | current | List of pm200frs02MondownRmonUnicastCounterClientOutput Article |
| 1.3.6.1.4.1.20044.90.11.2.4.688.1 | Rowpm200frs02MondownRmonUnicastCounterClientOutputEntry | not-accessible | current | Row definition for the pm200frs02MondownRmonUnicastCounterClientOutput table |
| 1.3.6.1.4.1.20044.90.11.2.4.688.1.1 | Columnpm200frs02MondownRmonUnicastCounterClientOutputIndex | read-only | current | Index definition for the pm200frs02MondownRmonUnicastCounterClientOutput table |
| 1.3.6.1.4.1.20044.90.11.2.4.688.1.2 | Columnpm200frs02MondownRmonUnicastCounterClientOutputValuePortn | read-only | current | Client Output Unicast Packets :This counter is increased each time a Unicast packet is transmitted on the client port <Help> This counter gives the number of U… |
| 1.3.6.1.4.1.20044.90.11.2.4.688.1.3 | Columnpm200frs02MondownRmonUnicastCounterClientOutputErrorPortn | read-only | current | Unicast Counter Error :This OID when set indicates the Unicast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.90.11.2.4.688.1.4 | Columnpm200frs02MondownRmonUnicastCounterClientOutputOverloadPortn | read-only | current | Unicast Counter Overload :This OID when set indicates a Unicast counter overload on client port |
| 1.3.6.1.4.1.20044.90.11.2.4.720 | Tablepm200frs02MondownRmonNonunicastCounterClientOutputTable | not-accessible | current | List of pm200frs02MondownRmonNonunicastCounterClientOutput Article |
| 1.3.6.1.4.1.20044.90.11.2.4.720.1 | Rowpm200frs02MondownRmonNonunicastCounterClientOutputEntry | not-accessible | current | Row definition for the pm200frs02MondownRmonNonunicastCounterClientOutput table |
| 1.3.6.1.4.1.20044.90.11.2.4.720.1.1 | Columnpm200frs02MondownRmonNonunicastCounterClientOutputIndex | read-only | current | Index definition for the pm200frs02MondownRmonNonunicastCounterClientOutput table |
| 1.3.6.1.4.1.20044.90.11.2.4.720.1.2 | Columnpm200frs02MondownRmonNonunicastCounterClientOutputValuePortn | read-only | current | Client Output Non Unicast Packets :This counter is increased each time a Non-Unicast packet is transmitted on the client port <Help> This counter gives the num… |
| 1.3.6.1.4.1.20044.90.11.2.4.720.1.3 | Columnpm200frs02MondownRmonNonunicastCounterClientOutputErrorPortn | read-only | current | Non Unicast Counter Error :This OID when set indicates the Non-Unicast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.90.11.2.4.720.1.4 | Columnpm200frs02MondownRmonNonunicastCounterClientOutputOverloadPortn | read-only | current | Non Unicast Counter Overload :This OID when set indicates a Non-Unicast counter overload on client port |
| 1.3.6.1.4.1.20044.90.11.5 | Nodepm200frs02MonPerfOther | |||
| 1.3.6.1.4.1.20044.90.11.5.1 | Nodepm200frs02MonPerfSync | |||
| 1.3.6.1.4.1.20044.90.11.5.1.257 | Scalarpm200frs02PerfEnable | read-write | current | Perf. Mon. Enable :This OID enables the Performance Monitoring application |
| 1.3.6.1.4.1.20044.90.11.5.1.259 | Scalarpm200frs02Perf15minSync | read-write | current | Perf. Mon. 15-min sync. :This OID must be used in external synchronisation mode only to send a 15-min synchronisation command |
| 1.3.6.1.4.1.20044.90.11.5.1.260 | Scalarpm200frs02Perf24hSync | read-write | current | Perf. Mon. 24-hours sync. :This OID must be used in external synchronisation mode only to send a 24-hours synchronisation command |
| 1.3.6.1.4.1.20044.90.11.5.2 | Nodepm200frs02MonPerfTimeStamp | |||
| 1.3.6.1.4.1.20044.90.11.5.2.1 | Scalarpm200frs02Perf15MinShort | read-write | current | 15-min period is short :This OID indicates that the 15-min period lasts less than 890 seconds |
| 1.3.6.1.4.1.20044.90.11.5.2.2 | Scalarpm200frs02Perf15MinLong | read-write | current | 15-min period is long :This OID indicates that the 15-min period lasts more than 910 seconds |
| 1.3.6.1.4.1.20044.90.11.5.2.5 | Scalarpm200frs02Perf24HoursShort | read-write | current | 24-hours period is short :This OID indicates that 24-hours period lasts less than 86390 seconds |
| 1.3.6.1.4.1.20044.90.11.5.2.6 | Scalarpm200frs02Perf24HoursLong | read-write | current | 24-hours period is long :This OID indicates that 24-hours period lasts more than 86410 seconds |
| 1.3.6.1.4.1.20044.90.11.5.2.7 | Scalarpm200frs02PerfCurrent15MinElapsedTime | read-write | current | Current 15min period Elapsed Time :This OID gives the number of seconds elapsed in the current 15-minutes period |
| 1.3.6.1.4.1.20044.90.11.5.2.8 | Scalarpm200frs02PerfCurrent24HoursElapsedTime | read-write | current | Current 24hours period Elapsed Time :This OID gives the number of seconds elapsed in the current 24-hours period |
| 1.3.6.1.4.1.20044.90.11.6 | Nodepm200frs02MonPerfClient | |||
| 1.3.6.1.4.1.20044.90.11.6.16 | Tablepm200frs02PerfTelecomInputClientCurrent15StatTable | not-accessible | current | List of pm200frs02PerfTelecomInputClientCurrent15Stat Article |
| 1.3.6.1.4.1.20044.90.11.6.16.1 | Rowpm200frs02PerfTelecomInputClientCurrent15StatEntry | not-accessible | current | Row definition for the pm200frs02PerfTelecomInputClientCurrent15Stat table |
| 1.3.6.1.4.1.20044.90.11.6.16.1.1 | Columnpm200frs02PerfTelecomInputClientCurrent15StatIndex | read-only | current | Index definition for the pm200frs02PerfTelecomInputClientCurrent15Stat table |
| 1.3.6.1.4.1.20044.90.11.6.16.1.2 | Columnpm200frs02PerfTelecomInputClientCurrent15StatInvCvPortn | read-only | current | Current 15-min EBC counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.16.1.3 | Columnpm200frs02PerfTelecomInputClientCurrent15StatCvValuePortn | read-only | current | Current 15-min EBC counter :This OID gives the current 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.90.11.6.16.1.4 | Columnpm200frs02PerfTelecomInputClientCurrent15StatInvEsPortn | read-only | current | Current 15-min ES counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.16.1.5 | Columnpm200frs02PerfTelecomInputClientCurrent15StatEsValuePortn | read-only | current | Current 15-min ES counter :This OID gives the current 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.16.1.6 | Columnpm200frs02PerfTelecomInputClientCurrent15StatInvSesPortn | read-only | current | Current 15-min SES counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.16.1.7 | Columnpm200frs02PerfTelecomInputClientCurrent15StatSesValuePortn | read-only | current | Current 15-min SES counter :This OID gives the current 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.16.1.8 | Columnpm200frs02PerfTelecomInputClientCurrent15StatInvSefsPortn | read-only | current | Current 15-min SEFS counter inv. :This OID indicates that the current 15-min severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.16.1.9 | Columnpm200frs02PerfTelecomInputClientCurrent15StatSefsValuePortn | read-only | current | Current 15-min SEFS counter :This OID gives the current 15-min severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.16.1.10 | Columnpm200frs02PerfTelecomInputClientCurrent15StatInvUasPortn | read-only | current | Current 15-min UAS counter inv. :This OID indicates that the current 15-min UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.16.1.11 | Columnpm200frs02PerfTelecomInputClientCurrent15StatUasValuePortn | read-only | current | Current 15-min UAS counter :This OID gives the current 15-min UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.48 | Tablepm200frs02PerfTelecomInputClientPast15StatHistoryPort1Table | not-accessible | current | List of pm200frs02PerfTelecomInputClientPast15StatHistory Article |
| 1.3.6.1.4.1.20044.90.11.6.48.1 | Rowpm200frs02PerfTelecomInputClientPast15StatHistoryPort1Entry | not-accessible | current | Row definition for the pm200frs02PerfTelecomInputClientPast15StatHistory table |
| 1.3.6.1.4.1.20044.90.11.6.48.1.1 | Columnpm200frs02PerfTelecomInputClientPast15StatHistoryPort1Index | read-only | current | Index definition for the pm200frs02PerfTelecomInputClientPast15StatHistory table |
| 1.3.6.1.4.1.20044.90.11.6.48.1.2 | Columnpm200frs02PerfTelecomInputClientPast15StatHistoryInvCvPort1 | read-only | current | Previous 15-min EBC counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.48.1.3 | Columnpm200frs02PerfTelecomInputClientPast15StatHistoryCvValuePort1 | read-only | current | Previous 15-min EBC counter :This OID gives the previous 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.90.11.6.48.1.4 | Columnpm200frs02PerfTelecomInputClientPast15StatHistoryInvEsPort1 | read-only | current | Previous 15-min ES counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.48.1.5 | Columnpm200frs02PerfTelecomInputClientPast15StatHistoryEsValuePort1 | read-only | current | Previous 15-min ES counter :This OID gives the previous 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.48.1.6 | Columnpm200frs02PerfTelecomInputClientPast15StatHistoryInvSesPort1 | read-only | current | Previous 15-min SES counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.48.1.7 | Columnpm200frs02PerfTelecomInputClientPast15StatHistorySesValuePort1 | read-only | current | Previous 15-min SES counter :This OID gives the previous 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.48.1.8 | Columnpm200frs02PerfTelecomInputClientPast15StatHistoryInvSefsPort1 | read-only | current | Previous 15-min SEFS counter inv. :This OID indicates that the previous 15-min severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.48.1.9 | Columnpm200frs02PerfTelecomInputClientPast15StatHistorySefsValuePort1 | read-only | current | Previous 15-min SEFS counter :This OID gives the previous 15-min severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.48.1.10 | Columnpm200frs02PerfTelecomInputClientPast15StatHistoryInvUasPort1 | read-only | current | Previous 15-min UAS counter inv. :This OID indicates that the previous 15-min UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.48.1.11 | Columnpm200frs02PerfTelecomInputClientPast15StatHistoryUasValuePort1 | read-only | current | Previous 15-min UAS counter :This OID gives the previous 15-min UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.80 | Tablepm200frs02PerfTelecomInputClientCurrent24StatTable | not-accessible | current | List of pm200frs02PerfTelecomInputClientCurrent24Stat Article |
| 1.3.6.1.4.1.20044.90.11.6.80.1 | Rowpm200frs02PerfTelecomInputClientCurrent24StatEntry | not-accessible | current | Row definition for the pm200frs02PerfTelecomInputClientCurrent24Stat table |
| 1.3.6.1.4.1.20044.90.11.6.80.1.1 | Columnpm200frs02PerfTelecomInputClientCurrent24StatIndex | read-only | current | Index definition for the pm200frs02PerfTelecomInputClientCurrent24Stat table |
| 1.3.6.1.4.1.20044.90.11.6.80.1.2 | Columnpm200frs02PerfTelecomInputClientCurrent24StatInvCvPortn | read-only | current | Current 24-hours EBC counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.80.1.3 | Columnpm200frs02PerfTelecomInputClientCurrent24StatCvValuePortn | read-only | current | Current 24-hours EBC counter :This OID gives the current 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.90.11.6.80.1.4 | Columnpm200frs02PerfTelecomInputClientCurrent24StatInvEsPortn | read-only | current | Current 24-hours ES counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.80.1.5 | Columnpm200frs02PerfTelecomInputClientCurrent24StatEsValuePortn | read-only | current | Current 24-hours ES counter :This OID gives the current 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.80.1.6 | Columnpm200frs02PerfTelecomInputClientCurrent24StatInvSesPortn | read-only | current | Current 24-hours SES counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.80.1.7 | Columnpm200frs02PerfTelecomInputClientCurrent24StatSesValuePortn | read-only | current | Current 24-hours SES counter :This OID gives the current 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.80.1.8 | Columnpm200frs02PerfTelecomInputClientCurrent24StatInvSefsPortn | read-only | current | Current 24-hours SEFS counter inv. :This OID indicates that the current 24-hours severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.80.1.9 | Columnpm200frs02PerfTelecomInputClientCurrent24StatSefsValuePortn | read-only | current | Current 24-hours SEFS counter :This OID gives the current 24-hours severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.80.1.10 | Columnpm200frs02PerfTelecomInputClientCurrent24StatInvUasPortn | read-only | current | Current 24-hours UAS counter inv. :This OID indicates that the current 24-hours UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.80.1.11 | Columnpm200frs02PerfTelecomInputClientCurrent24StatUasValuePortn | read-only | current | Current 24-hours UAS counter :This OID gives the current 24-hours UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.112 | Tablepm200frs02PerfTelecomInputClientPast24StatHistoryPort1Table | not-accessible | current | List of pm200frs02PerfTelecomInputClientPast24StatHistory Article |
| 1.3.6.1.4.1.20044.90.11.6.112.1 | Rowpm200frs02PerfTelecomInputClientPast24StatHistoryPort1Entry | not-accessible | current | Row definition for the pm200frs02PerfTelecomInputClientPast24StatHistory table |
| 1.3.6.1.4.1.20044.90.11.6.112.1.1 | Columnpm200frs02PerfTelecomInputClientPast24StatHistoryPort1Index | read-only | current | Index definition for the pm200frs02PerfTelecomInputClientPast24StatHistory table |
| 1.3.6.1.4.1.20044.90.11.6.112.1.2 | Columnpm200frs02PerfTelecomInputClientPast24StatHistoryInvCvPort1 | read-only | current | Previous 24-hours EBC counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.112.1.3 | Columnpm200frs02PerfTelecomInputClientPast24StatHistoryCvValuePort1 | read-only | current | Previous 24-hours EBC counter :This OID gives the previous 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.90.11.6.112.1.4 | Columnpm200frs02PerfTelecomInputClientPast24StatHistoryInvEsPort1 | read-only | current | Previous 24-hours ES counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.112.1.5 | Columnpm200frs02PerfTelecomInputClientPast24StatHistoryEsValuePort1 | read-only | current | Previous 24-hours ES counter :This OID gives the previous 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.112.1.6 | Columnpm200frs02PerfTelecomInputClientPast24StatHistoryInvSesPort1 | read-only | current | Previous 24-hours SES counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.112.1.7 | Columnpm200frs02PerfTelecomInputClientPast24StatHistorySesValuePort1 | read-only | current | Previous 24-hours SES counter :This OID gives the previous 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.112.1.8 | Columnpm200frs02PerfTelecomInputClientPast24StatHistoryInvSefsPort1 | read-only | current | Previous 24-hours SEFS counter inv. :This OID indicates that the previous 24-hours severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.112.1.9 | Columnpm200frs02PerfTelecomInputClientPast24StatHistorySefsValuePort1 | read-only | current | Previous 24-hours SEFS counter :This OID gives the previous 24-hours severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.112.1.10 | Columnpm200frs02PerfTelecomInputClientPast24StatHistoryInvUasPort1 | read-only | current | Previous 24-hours UAS counter inv. :This OID indicates that the previous 24-hours UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.112.1.11 | Columnpm200frs02PerfTelecomInputClientPast24StatHistoryUasValuePort1 | read-only | current | Previous 24-hours UAS counter :This OID gives the previous 24-hours UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.144 | Tablepm200frs02PerfTelecomOutputClientCurrent15StatTable | not-accessible | current | List of pm200frs02PerfTelecomOutputClientCurrent15Stat Article |
| 1.3.6.1.4.1.20044.90.11.6.144.1 | Rowpm200frs02PerfTelecomOutputClientCurrent15StatEntry | not-accessible | current | Row definition for the pm200frs02PerfTelecomOutputClientCurrent15Stat table |
| 1.3.6.1.4.1.20044.90.11.6.144.1.1 | Columnpm200frs02PerfTelecomOutputClientCurrent15StatIndex | read-only | current | Index definition for the pm200frs02PerfTelecomOutputClientCurrent15Stat table |
| 1.3.6.1.4.1.20044.90.11.6.144.1.2 | Columnpm200frs02PerfTelecomOutputClientCurrent15StatInvCvPortn | read-only | current | Current 15-min EBC counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.144.1.3 | Columnpm200frs02PerfTelecomOutputClientCurrent15StatCvValuePortn | read-only | current | Current 15-min EBC counter :This OID gives the current 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.90.11.6.144.1.4 | Columnpm200frs02PerfTelecomOutputClientCurrent15StatInvEsPortn | read-only | current | Current 15-min ES counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.144.1.5 | Columnpm200frs02PerfTelecomOutputClientCurrent15StatEsValuePortn | read-only | current | Current 15-min ES counter :This OID gives the current 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.144.1.6 | Columnpm200frs02PerfTelecomOutputClientCurrent15StatInvSesPortn | read-only | current | Current 15-min SES counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.144.1.7 | Columnpm200frs02PerfTelecomOutputClientCurrent15StatSesValuePortn | read-only | current | Current 15-min SES counter :This OID gives the current 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.144.1.8 | Columnpm200frs02PerfTelecomOutputClientCurrent15StatInvSefsPortn | read-only | current | Current 15-min SEFS counter inv. :This OID indicates that the current 15-min severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.144.1.9 | Columnpm200frs02PerfTelecomOutputClientCurrent15StatSefsValuePortn | read-only | current | Current 15-min SEFS counter :This OID gives the current 15-min severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.144.1.10 | Columnpm200frs02PerfTelecomOutputClientCurrent15StatInvUasPortn | read-only | current | Current 15-min UAS counter inv. :This OID indicates that the current 15-min UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.144.1.11 | Columnpm200frs02PerfTelecomOutputClientCurrent15StatUasValuePortn | read-only | current | Current 15-min UAS counter :This OID gives the current 15-min UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.176 | Tablepm200frs02PerfTelecomOutputClientPast15StatHistoryPort1Table | not-accessible | current | List of pm200frs02PerfTelecomOutputClientPast15StatHistory Article |
| 1.3.6.1.4.1.20044.90.11.6.176.1 | Rowpm200frs02PerfTelecomOutputClientPast15StatHistoryPort1Entry | not-accessible | current | Row definition for the pm200frs02PerfTelecomOutputClientPast15StatHistory table |
| 1.3.6.1.4.1.20044.90.11.6.176.1.1 | Columnpm200frs02PerfTelecomOutputClientPast15StatHistoryPort1Index | read-only | current | Index definition for the pm200frs02PerfTelecomOutputClientPast15StatHistory table |
| 1.3.6.1.4.1.20044.90.11.6.176.1.2 | Columnpm200frs02PerfTelecomOutputClientPast15StatHistoryInvCvPort1 | read-only | current | Previous 15-min EBC counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.176.1.3 | Columnpm200frs02PerfTelecomOutputClientPast15StatHistoryCvValuePort1 | read-only | current | Previous 15-min EBC counter :This OID gives the previous 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.90.11.6.176.1.4 | Columnpm200frs02PerfTelecomOutputClientPast15StatHistoryInvEsPort1 | read-only | current | Previous 15-min ES counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.176.1.5 | Columnpm200frs02PerfTelecomOutputClientPast15StatHistoryEsValuePort1 | read-only | current | Previous 15-min ES counter :This OID gives the previous 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.176.1.6 | Columnpm200frs02PerfTelecomOutputClientPast15StatHistoryInvSesPort1 | read-only | current | Previous 15-min SES counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.176.1.7 | Columnpm200frs02PerfTelecomOutputClientPast15StatHistorySesValuePort1 | read-only | current | Previous 15-min SES counter :This OID gives the previous 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.176.1.8 | Columnpm200frs02PerfTelecomOutputClientPast15StatHistoryInvSefsPort1 | read-only | current | Previous 15-min SEFS counter inv. :This OID indicates that the previous 15-min severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.176.1.9 | Columnpm200frs02PerfTelecomOutputClientPast15StatHistorySefsValuePort1 | read-only | current | Previous 15-min SEFS counter :This OID gives the previous 15-min severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.176.1.10 | Columnpm200frs02PerfTelecomOutputClientPast15StatHistoryInvUasPort1 | read-only | current | Previous 15-min UAS counter inv. :This OID indicates that the previous 15-min UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.176.1.11 | Columnpm200frs02PerfTelecomOutputClientPast15StatHistoryUasValuePort1 | read-only | current | Previous 15-min UAS counter :This OID gives the previous 15-min UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.208 | Tablepm200frs02PerfTelecomOutputClientCurrent24StatTable | not-accessible | current | List of pm200frs02PerfTelecomOutputClientCurrent24Stat Article |
| 1.3.6.1.4.1.20044.90.11.6.208.1 | Rowpm200frs02PerfTelecomOutputClientCurrent24StatEntry | not-accessible | current | Row definition for the pm200frs02PerfTelecomOutputClientCurrent24Stat table |
| 1.3.6.1.4.1.20044.90.11.6.208.1.1 | Columnpm200frs02PerfTelecomOutputClientCurrent24StatIndex | read-only | current | Index definition for the pm200frs02PerfTelecomOutputClientCurrent24Stat table |
| 1.3.6.1.4.1.20044.90.11.6.208.1.2 | Columnpm200frs02PerfTelecomOutputClientCurrent24StatInvCvPortn | read-only | current | Current 24-hours EBC counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.208.1.3 | Columnpm200frs02PerfTelecomOutputClientCurrent24StatCvValuePortn | read-only | current | Current 24-hours EBC counter :This OID gives the current 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.90.11.6.208.1.4 | Columnpm200frs02PerfTelecomOutputClientCurrent24StatInvEsPortn | read-only | current | Current 24-hours ES counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.208.1.5 | Columnpm200frs02PerfTelecomOutputClientCurrent24StatEsValuePortn | read-only | current | Current 24-hours ES counter :This OID gives the current 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.208.1.6 | Columnpm200frs02PerfTelecomOutputClientCurrent24StatInvSesPortn | read-only | current | Current 24-hours SES counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.208.1.7 | Columnpm200frs02PerfTelecomOutputClientCurrent24StatSesValuePortn | read-only | current | Current 24-hours SES counter :This OID gives the current 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.208.1.8 | Columnpm200frs02PerfTelecomOutputClientCurrent24StatInvSefsPortn | read-only | current | Current 24-hours SEFS counter inv. :This OID indicates that the current 24-hours severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.208.1.9 | Columnpm200frs02PerfTelecomOutputClientCurrent24StatSefsValuePortn | read-only | current | Current 24-hours SEFS counter :This OID gives the current 24-hours severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.208.1.10 | Columnpm200frs02PerfTelecomOutputClientCurrent24StatInvUasPortn | read-only | current | Current 24-hours UAS counter inv. :This OID indicates that the current 24-hours UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.208.1.11 | Columnpm200frs02PerfTelecomOutputClientCurrent24StatUasValuePortn | read-only | current | Current 24-hours UAS counter :This OID gives the current 24-hours UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.240 | Tablepm200frs02PerfTelecomOutputClientPast24StatHistoryPort1Table | not-accessible | current | List of pm200frs02PerfTelecomOutputClientPast24StatHistory Article |
| 1.3.6.1.4.1.20044.90.11.6.240.1 | Rowpm200frs02PerfTelecomOutputClientPast24StatHistoryPort1Entry | not-accessible | current | Row definition for the pm200frs02PerfTelecomOutputClientPast24StatHistory table |
| 1.3.6.1.4.1.20044.90.11.6.240.1.1 | Columnpm200frs02PerfTelecomOutputClientPast24StatHistoryPort1Index | read-only | current | Index definition for the pm200frs02PerfTelecomOutputClientPast24StatHistory table |
| 1.3.6.1.4.1.20044.90.11.6.240.1.2 | Columnpm200frs02PerfTelecomOutputClientPast24StatHistoryInvCvPort1 | read-only | current | Previous 24-hours EBC counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.240.1.3 | Columnpm200frs02PerfTelecomOutputClientPast24StatHistoryCvValuePort1 | read-only | current | Previous 24-hours EBC counter :This OID gives the previous 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.90.11.6.240.1.4 | Columnpm200frs02PerfTelecomOutputClientPast24StatHistoryInvEsPort1 | read-only | current | Previous 24-hours ES counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.240.1.5 | Columnpm200frs02PerfTelecomOutputClientPast24StatHistoryEsValuePort1 | read-only | current | Previous 24-hours ES counter :This OID gives the previous 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.240.1.6 | Columnpm200frs02PerfTelecomOutputClientPast24StatHistoryInvSesPort1 | read-only | current | Previous 24-hours SES counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.240.1.7 | Columnpm200frs02PerfTelecomOutputClientPast24StatHistorySesValuePort1 | read-only | current | Previous 24-hours SES counter :This OID gives the previous 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.240.1.8 | Columnpm200frs02PerfTelecomOutputClientPast24StatHistoryInvSefsPort1 | read-only | current | Previous 24-hours SEFS counter inv. :This OID indicates that the previous 24-hours severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.240.1.9 | Columnpm200frs02PerfTelecomOutputClientPast24StatHistorySefsValuePort1 | read-only | current | Previous 24-hours SEFS counter :This OID gives the previous 24-hours severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.240.1.10 | Columnpm200frs02PerfTelecomOutputClientPast24StatHistoryInvUasPort1 | read-only | current | Previous 24-hours UAS counter inv. :This OID indicates that the previous 24-hours UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.240.1.11 | Columnpm200frs02PerfTelecomOutputClientPast24StatHistoryUasValuePort1 | read-only | current | Previous 24-hours UAS counter :This OID gives the previous 24-hours UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.90.11.6.848 | Tablepm200frs02PerfDatacomClientCurrent15StatTable | not-accessible | current | List of pm200frs02PerfDatacomClientCurrent15Stat Article |
| 1.3.6.1.4.1.20044.90.11.6.848.1 | Rowpm200frs02PerfDatacomClientCurrent15StatEntry | not-accessible | current | Row definition for the pm200frs02PerfDatacomClientCurrent15Stat table |
| 1.3.6.1.4.1.20044.90.11.6.848.1.1 | Columnpm200frs02PerfDatacomClientCurrent15StatIndex | read-only | current | Index definition for the pm200frs02PerfDatacomClientCurrent15Stat table |
| 1.3.6.1.4.1.20044.90.11.6.848.1.4 | Columnpm200frs02perfdatacomclientCurrent15StatInCrcCountInvPortn | read-only | current | Client Current 15-min Input CRC counter inv. :This OID indicates that the current 15-min Input CRC counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.848.1.5 | Columnpm200frs02perfdatacomclientCurrent15StatInCrcCountPortn | read-only | current | Client Current 15-min Input CRC counter :This OID gives the current 15-min Input CRC counter value |
| 1.3.6.1.4.1.20044.90.11.6.848.1.6 | Columnpm200frs02perfdatacomclientCurrent15StatInPacketCountInvPortn | read-only | current | Client Current 15-min Input Packet counter inv. :This OID indicates that the current 15-min Input Packet counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.848.1.7 | Columnpm200frs02perfdatacomclientCurrent15StatInPacketCountPortn | read-only | current | Client Current 15-min Input Packet counter :This OID gives the current 15-min Input Packet counter value |
| 1.3.6.1.4.1.20044.90.11.6.848.1.28 | Columnpm200frs02perfdatacomclientCurrent15StatOutCrcCountInvPortn | read-only | current | Client Current 15-min Output CRC counter inv. :This OID indicates that the current 15-min Output CRC counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.848.1.29 | Columnpm200frs02perfdatacomclientCurrent15StatOutCrcCountPortn | read-only | current | Client Current 15-min Output CRC counter :This OID gives the current 15-min Output CRC counter value |
| 1.3.6.1.4.1.20044.90.11.6.848.1.30 | Columnpm200frs02perfdatacomclientCurrent15StatOutPacketCountInvPortn | read-only | current | Client Current 15-min Output Packet counter inv. :This OID indicates that the current 15-min Output Packets counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.848.1.31 | Columnpm200frs02perfdatacomclientCurrent15StatOutPacketCountPortn | read-only | current | Client Current 15-min Output Packet counter :This OID gives the current 15-min Output Packets counter value |
| 1.3.6.1.4.1.20044.90.11.6.880 | Tablepm200frs02PerfDatacomClientPast15StatHistoryPort1Table | not-accessible | current | List of pm200frs02PerfDatacomClientPast15StatHistory Article |
| 1.3.6.1.4.1.20044.90.11.6.880.1 | Rowpm200frs02PerfDatacomClientPast15StatHistoryPort1Entry | not-accessible | current | Row definition for the pm200frs02PerfDatacomClientPast15StatHistory table |
| 1.3.6.1.4.1.20044.90.11.6.880.1.1 | Columnpm200frs02PerfDatacomClientPast15StatHistoryPort1Index | read-only | current | Index definition for the pm200frs02PerfDatacomClientPast15StatHistory table |
| 1.3.6.1.4.1.20044.90.11.6.880.1.4 | Columnpm200frs02perfdatacomclientPast15StatInCrcCountInvPort1 | read-only | current | Client Past 15-min Input CRC counter inv. :This OID indicates that the past 15-min Input CRC counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.880.1.5 | Columnpm200frs02perfdatacomclientPast15StatInCrcCountPort1 | read-only | current | Client Past 15-min Input CRC counter :This OID gives the past 15-min Input CRC counter value |
| 1.3.6.1.4.1.20044.90.11.6.880.1.6 | Columnpm200frs02perfdatacomclientPast15StatInPacketCountInvPort1 | read-only | current | Client Past 15-min Input Packet counter inv. :This OID indicates that the past 15-min Input Packet counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.880.1.7 | Columnpm200frs02perfdatacomclientPast15StatInPacketCountPort1 | read-only | current | Client Past 15-min Input Packet counter :This OID gives the past 15-min Input Packet counter value |
| 1.3.6.1.4.1.20044.90.11.6.880.1.28 | Columnpm200frs02perfdatacomclientPast15StatOutCrcCountInvPort1 | read-only | current | Client Past 15-min Output CRC counter inv. :This OID indicates that the past 15-min Output CRC counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.880.1.29 | Columnpm200frs02perfdatacomclientPast15StatOutCrcCountPort1 | read-only | current | Client Past 15-min Output CRC counter :This OID gives the past 15-min Output CRC counter value |
| 1.3.6.1.4.1.20044.90.11.6.880.1.30 | Columnpm200frs02perfdatacomclientPast15StatOutPacketCountInvPort1 | read-only | current | Client Past 15-min Output Packet counter inv. :This OID indicates that the past 15-min Output Packets counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.880.1.31 | Columnpm200frs02perfdatacomclientPast15StatOutPacketCountPort1 | read-only | current | Client Past 15-min Output Packet counter :This OID gives the past 15-min Output Packets counter value |
| 1.3.6.1.4.1.20044.90.11.6.912 | Tablepm200frs02PerfDatacomClientCurrent24StatTable | not-accessible | current | List of pm200frs02PerfDatacomClientCurrent24Stat Article |
| 1.3.6.1.4.1.20044.90.11.6.912.1 | Rowpm200frs02PerfDatacomClientCurrent24StatEntry | not-accessible | current | Row definition for the pm200frs02PerfDatacomClientCurrent24Stat table |
| 1.3.6.1.4.1.20044.90.11.6.912.1.1 | Columnpm200frs02PerfDatacomClientCurrent24StatIndex | read-only | current | Index definition for the pm200frs02PerfDatacomClientCurrent24Stat table |
| 1.3.6.1.4.1.20044.90.11.6.912.1.4 | Columnpm200frs02perfdatacomclientCurrent24StatInCrcCountInvPortn | read-only | current | Client Current 24-hours Input CRC counter inv. :This OID indicates that the current 24-hours Input CRC counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.912.1.5 | Columnpm200frs02perfdatacomclientCurrent24StatInCrcCountPortn | read-only | current | Client Current 24-hours Input CRC counter :This OID gives the current 24-hours Input CRC counter value |
| 1.3.6.1.4.1.20044.90.11.6.912.1.6 | Columnpm200frs02perfdatacomclientCurrent24StatInPacketCountInvPortn | read-only | current | Client Current 24-hours Input Packet counter inv. :This OID indicates that the current 24-hours Input Packet counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.912.1.7 | Columnpm200frs02perfdatacomclientCurrent24StatInPacketCountPortn | read-only | current | Client Current 24-hours Input Packet counter :This OID gives the current 24-hours Input Packet counter value |
| 1.3.6.1.4.1.20044.90.11.6.912.1.28 | Columnpm200frs02perfdatacomclientCurrent24StatOutCrcCountInvPortn | read-only | current | Client Current 24-hours Output CRC counter inv. :This OID indicates that the current 24-hours Output CRC counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.912.1.29 | Columnpm200frs02perfdatacomclientCurrent24StatOutCrcCountPortn | read-only | current | Client Current 24-hours Output CRC counter :This OID gives the current 24-hours Output CRC counter value |
| 1.3.6.1.4.1.20044.90.11.6.912.1.30 | Columnpm200frs02perfdatacomclientCurrent24StatOutPacketCountInvPortn | read-only | current | Client Current 24-hours Output Packet counter inv. :This OID indicates that the current 24-hours Output Packets counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.912.1.31 | Columnpm200frs02perfdatacomclientCurrent24StatOutPacketCountPortn | read-only | current | Client Current 24-hours Output Packet counter :This OID gives the current 24-hours Output Packets counter value |
| 1.3.6.1.4.1.20044.90.11.6.944 | Tablepm200frs02PerfDatacomClientPast24StatHistoryPort1Table | not-accessible | current | List of pm200frs02PerfDatacomClientPast24StatHistory Article |
| 1.3.6.1.4.1.20044.90.11.6.944.1 | Rowpm200frs02PerfDatacomClientPast24StatHistoryPort1Entry | not-accessible | current | Row definition for the pm200frs02PerfDatacomClientPast24StatHistory table |
| 1.3.6.1.4.1.20044.90.11.6.944.1.1 | Columnpm200frs02PerfDatacomClientPast24StatHistoryPort1Index | read-only | current | Index definition for the pm200frs02PerfDatacomClientPast24StatHistory table |
| 1.3.6.1.4.1.20044.90.11.6.944.1.4 | Columnpm200frs02perfdatacomclientPast24StatInCrcCountInvPort1 | read-only | current | Client Past 24-hours Input CRC counter inv. :This OID indicates that the past 24-hours Input CRC counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.944.1.5 | Columnpm200frs02perfdatacomclientPast24StatInCrcCountPort1 | read-only | current | Client Past 24-hours Input CRC counter :This OID gives the past 24-hours Input CRC counter value |
| 1.3.6.1.4.1.20044.90.11.6.944.1.6 | Columnpm200frs02perfdatacomclientPast24StatInPacketCountInvPort1 | read-only | current | Client Past 24-hours Input Packet counter inv. :This OID indicates that the past 24-hours Input Packet counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.944.1.7 | Columnpm200frs02perfdatacomclientPast24StatInPacketCountPort1 | read-only | current | Client Past 24-hours Input Packet counter :This OID gives the past 24-hours Input Packet counter value |
| 1.3.6.1.4.1.20044.90.11.6.944.1.28 | Columnpm200frs02perfdatacomclientPast24StatOutCrcCountInvPort1 | read-only | current | Client Past 24-hours Output CRC counter inv. :This OID indicates that the past 24-hours Output CRC counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.944.1.29 | Columnpm200frs02perfdatacomclientPast24StatOutCrcCountPort1 | read-only | current | Client Past 24-hours Output CRC counter :This OID gives the past 24-hours Output CRC counter value |
| 1.3.6.1.4.1.20044.90.11.6.944.1.30 | Columnpm200frs02perfdatacomclientPast24StatOutPacketCountInvPort1 | read-only | current | Client Past 24-hours Output Packet counter inv. :This OID indicates that the past 24-hours Output Packets counter is invalid |
| 1.3.6.1.4.1.20044.90.11.6.944.1.31 | Columnpm200frs02perfdatacomclientPast24StatOutPacketCountPort1 | read-only | current | Client Past 24-hours Output Packet counter :This OID gives the past 24-hours Output Packets counter value |
| 1.3.6.1.4.1.20044.90.11.7 | Nodepm200frs02MonPerfLine | |||
| 1.3.6.1.4.1.20044.90.11.7.336 | Tablepm200frs02PerfTelecomLinePostFecCurrent15StatTable | not-accessible | current | List of pm200frs02PerfTelecomLinePostFecCurrent15Stat Article |
| 1.3.6.1.4.1.20044.90.11.7.336.1 | Rowpm200frs02PerfTelecomLinePostFecCurrent15StatEntry | not-accessible | current | Row definition for the pm200frs02PerfTelecomLinePostFecCurrent15Stat table |
| 1.3.6.1.4.1.20044.90.11.7.336.1.1 | Columnpm200frs02PerfTelecomLinePostFecCurrent15StatIndex | read-only | current | Index definition for the pm200frs02PerfTelecomLinePostFecCurrent15Stat table |
| 1.3.6.1.4.1.20044.90.11.7.336.1.2 | Columnpm200frs02PerfTelecomLinePostFecCurrent15StatInvCvPortn | read-only | current | Current 15-min EBC counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.336.1.3 | Columnpm200frs02PerfTelecomLinePostFecCurrent15StatCvValuePortn | read-only | current | Current 15-min EBC counter :This OID gives the current 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.90.11.7.336.1.4 | Columnpm200frs02PerfTelecomLinePostFecCurrent15StatInvEsPortn | read-only | current | Current 15-min ES counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.336.1.5 | Columnpm200frs02PerfTelecomLinePostFecCurrent15StatEsValuePortn | read-only | current | Current 15-min ES counter :This OID gives the current 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.90.11.7.336.1.6 | Columnpm200frs02PerfTelecomLinePostFecCurrent15StatInvSesPortn | read-only | current | Current 15-min SES counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.336.1.7 | Columnpm200frs02PerfTelecomLinePostFecCurrent15StatSesValuePortn | read-only | current | Current 15-min SES counter :This OID gives the current 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.90.11.7.336.1.8 | Columnpm200frs02PerfTelecomLinePostFecCurrent15StatInvSefsPortn | read-only | current | Current 15-min SEFS counter inv. :This OID indicates that the current 15-min severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.336.1.9 | Columnpm200frs02PerfTelecomLinePostFecCurrent15StatSefsValuePortn | read-only | current | Current 15-min SEFS counter :This OID gives the current 15-min severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.90.11.7.336.1.10 | Columnpm200frs02PerfTelecomLinePostFecCurrent15StatInvUasPortn | read-only | current | Current 15-min UAS counter inv. :This OID indicates that the current 15-min UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.336.1.11 | Columnpm200frs02PerfTelecomLinePostFecCurrent15StatUasValuePortn | read-only | current | Current 15-min UAS counter :This OID gives the current 15-min UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.90.11.7.337 | Tablepm200frs02PerfTelecomLinePostFecPast15StatHistoryPort1Table | not-accessible | current | List of pm200frs02PerfTelecomLinePostFecPast15StatHistory Article |
| 1.3.6.1.4.1.20044.90.11.7.337.1 | Rowpm200frs02PerfTelecomLinePostFecPast15StatHistoryPort1Entry | not-accessible | current | Row definition for the pm200frs02PerfTelecomLinePostFecPast15StatHistory table |
| 1.3.6.1.4.1.20044.90.11.7.337.1.1 | Columnpm200frs02PerfTelecomLinePostFecPast15StatHistoryPort1Index | read-only | current | Index definition for the pm200frs02PerfTelecomLinePostFecPast15StatHistory table |
| 1.3.6.1.4.1.20044.90.11.7.337.1.2 | Columnpm200frs02PerfTelecomLinePostFecPast15StatHistoryInvCvPort1 | read-only | current | Previous 15-min EBC counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.337.1.3 | Columnpm200frs02PerfTelecomLinePostFecPast15StatHistoryCvValuePort1 | read-only | current | Previous 15-min EBC counter :This OID gives the previous 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.90.11.7.337.1.4 | Columnpm200frs02PerfTelecomLinePostFecPast15StatHistoryInvEsPort1 | read-only | current | Previous 15-min ES counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.337.1.5 | Columnpm200frs02PerfTelecomLinePostFecPast15StatHistoryEsValuePort1 | read-only | current | Previous 15-min ES counter :This OID gives the previous 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.90.11.7.337.1.6 | Columnpm200frs02PerfTelecomLinePostFecPast15StatHistoryInvSesPort1 | read-only | current | Previous 15-min SES counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.337.1.7 | Columnpm200frs02PerfTelecomLinePostFecPast15StatHistorySesValuePort1 | read-only | current | Previous 15-min SES counter :This OID gives the previous 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.90.11.7.337.1.8 | Columnpm200frs02PerfTelecomLinePostFecPast15StatHistoryInvSefsPort1 | read-only | current | Previous 15-min SEFS counter inv. :This OID indicates that the previous 15-min severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.337.1.9 | Columnpm200frs02PerfTelecomLinePostFecPast15StatHistorySefsValuePort1 | read-only | current | Previous 15-min SEFS counter :This OID gives the previous 15-min severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.90.11.7.337.1.10 | Columnpm200frs02PerfTelecomLinePostFecPast15StatHistoryInvUasPort1 | read-only | current | Previous 15-min UAS counter inv. :This OID indicates that the previous 15-min UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.337.1.11 | Columnpm200frs02PerfTelecomLinePostFecPast15StatHistoryUasValuePort1 | read-only | current | Previous 15-min UAS counter :This OID gives the previous 15-min UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.90.11.7.338 | Tablepm200frs02PerfTelecomLinePostFecCurrent24StatTable | not-accessible | current | List of pm200frs02PerfTelecomLinePostFecCurrent24Stat Article |
| 1.3.6.1.4.1.20044.90.11.7.338.1 | Rowpm200frs02PerfTelecomLinePostFecCurrent24StatEntry | not-accessible | current | Row definition for the pm200frs02PerfTelecomLinePostFecCurrent24Stat table |
| 1.3.6.1.4.1.20044.90.11.7.338.1.1 | Columnpm200frs02PerfTelecomLinePostFecCurrent24StatIndex | read-only | current | Index definition for the pm200frs02PerfTelecomLinePostFecCurrent24Stat table |
| 1.3.6.1.4.1.20044.90.11.7.338.1.2 | Columnpm200frs02PerfTelecomLinePostFecCurrent24StatInvCvPortn | read-only | current | Current 24-hours EBC counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.338.1.3 | Columnpm200frs02PerfTelecomLinePostFecCurrent24StatCvValuePortn | read-only | current | Current 24-hours EBC counter :This OID gives the current 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.90.11.7.338.1.4 | Columnpm200frs02PerfTelecomLinePostFecCurrent24StatInvEsPortn | read-only | current | Current 24-hours ES counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.338.1.5 | Columnpm200frs02PerfTelecomLinePostFecCurrent24StatEsValuePortn | read-only | current | Current 24-hours ES counter :This OID gives the current 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.90.11.7.338.1.6 | Columnpm200frs02PerfTelecomLinePostFecCurrent24StatInvSesPortn | read-only | current | Current 24-hours SES counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.338.1.7 | Columnpm200frs02PerfTelecomLinePostFecCurrent24StatSesValuePortn | read-only | current | Current 24-hours SES counter :This OID gives the current 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.90.11.7.338.1.8 | Columnpm200frs02PerfTelecomLinePostFecCurrent24StatInvSefsPortn | read-only | current | Current 24-hours SEFS counter inv. :This OID indicates that the current 24-hours severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.338.1.9 | Columnpm200frs02PerfTelecomLinePostFecCurrent24StatSefsValuePortn | read-only | current | Current 24-hours SEFS counter :This OID gives the current 24-hours severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.90.11.7.338.1.10 | Columnpm200frs02PerfTelecomLinePostFecCurrent24StatInvUasPortn | read-only | current | Current 24-hours UAS counter inv. :This OID indicates that the current 24-hours UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.338.1.11 | Columnpm200frs02PerfTelecomLinePostFecCurrent24StatUasValuePortn | read-only | current | Current 24-hours UAS counter :This OID gives the current 24-hours UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.90.11.7.339 | Tablepm200frs02PerfTelecomLinePostFecPast24StatHistoryPort1Table | not-accessible | current | List of pm200frs02PerfTelecomLinePostFecPast24StatHistory Article |
| 1.3.6.1.4.1.20044.90.11.7.339.1 | Rowpm200frs02PerfTelecomLinePostFecPast24StatHistoryPort1Entry | not-accessible | current | Row definition for the pm200frs02PerfTelecomLinePostFecPast24StatHistory table |
| 1.3.6.1.4.1.20044.90.11.7.339.1.1 | Columnpm200frs02PerfTelecomLinePostFecPast24StatHistoryPort1Index | read-only | current | Index definition for the pm200frs02PerfTelecomLinePostFecPast24StatHistory table |
| 1.3.6.1.4.1.20044.90.11.7.339.1.2 | Columnpm200frs02PerfTelecomLinePostFecPast24StatHistoryInvCvPort1 | read-only | current | Previous 24-hours EBC counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.339.1.3 | Columnpm200frs02PerfTelecomLinePostFecPast24StatHistoryCvValuePort1 | read-only | current | Previous 24-hours EBC counter :This OID gives the previous 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.90.11.7.339.1.4 | Columnpm200frs02PerfTelecomLinePostFecPast24StatHistoryInvEsPort1 | read-only | current | Previous 24-hours ES counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.339.1.5 | Columnpm200frs02PerfTelecomLinePostFecPast24StatHistoryEsValuePort1 | read-only | current | Previous 24-hours ES counter :This OID gives the previous 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.90.11.7.339.1.6 | Columnpm200frs02PerfTelecomLinePostFecPast24StatHistoryInvSesPort1 | read-only | current | Previous 24-hours SES counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.339.1.7 | Columnpm200frs02PerfTelecomLinePostFecPast24StatHistorySesValuePort1 | read-only | current | Previous 24-hours SES counter :This OID gives the previous 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.90.11.7.339.1.8 | Columnpm200frs02PerfTelecomLinePostFecPast24StatHistoryInvSefsPort1 | read-only | current | Previous 24-hours SEFS counter inv. :This OID indicates that the previous 24-hours severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.339.1.9 | Columnpm200frs02PerfTelecomLinePostFecPast24StatHistorySefsValuePort1 | read-only | current | Previous 24-hours SEFS counter :This OID gives the previous 24-hours severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.90.11.7.339.1.10 | Columnpm200frs02PerfTelecomLinePostFecPast24StatHistoryInvUasPort1 | read-only | current | Previous 24-hours UAS counter inv. :This OID indicates that the previous 24-hours UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.339.1.11 | Columnpm200frs02PerfTelecomLinePostFecPast24StatHistoryUasValuePort1 | read-only | current | Previous 24-hours UAS counter :This OID gives the previous 24-hours UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.90.11.7.352 | Tablepm200frs02PerfTelecomBerLinePreFecCurrent15StatTable | not-accessible | current | List of pm200frs02PerfTelecomBerLinePreFecCurrent15Stat Article |
| 1.3.6.1.4.1.20044.90.11.7.352.1 | Rowpm200frs02PerfTelecomBerLinePreFecCurrent15StatEntry | not-accessible | current | Row definition for the pm200frs02PerfTelecomBerLinePreFecCurrent15Stat table |
| 1.3.6.1.4.1.20044.90.11.7.352.1.1 | Columnpm200frs02PerfTelecomBerLinePreFecCurrent15StatIndex | read-only | current | Index definition for the pm200frs02PerfTelecomBerLinePreFecCurrent15Stat table |
| 1.3.6.1.4.1.20044.90.11.7.352.1.2 | Columnpm200frs02PerfTelecomBerLinePreFecCurrent15StatInvBerPortn | read-only | current | Current 15-min BER counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.352.1.3 | Columnpm200frs02PerfTelecomBerLinePreFecCurrent15StatBerValuePortn | read-only | current | Current 15-min BER counter :This OID gives the current 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.90.11.7.352.1.4 | Columnpm200frs02PerfTelecomBerLinePreFecCurrent15StatInvMinBerPortn | read-only | current | Current 15-min MinBER counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.352.1.5 | Columnpm200frs02PerfTelecomBerLinePreFecCurrent15StatMinBerValuePortn | read-only | current | Current 15-min MinBER counter :This OID gives the current 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.90.11.7.352.1.6 | Columnpm200frs02PerfTelecomBerLinePreFecCurrent15StatInvMaxBerPortn | read-only | current | Current 15-min MaxBER counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.352.1.7 | Columnpm200frs02PerfTelecomBerLinePreFecCurrent15StatMaxBerValuePortn | read-only | current | Current 15-min MaxBER counter :This OID gives the current 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.90.11.7.353 | Tablepm200frs02PerfTelecomBerLinePreFecPast15StatHistoryPort1Table | not-accessible | current | List of pm200frs02PerfTelecomBerLinePreFecPast15StatHistory Article |
| 1.3.6.1.4.1.20044.90.11.7.353.1 | Rowpm200frs02PerfTelecomBerLinePreFecPast15StatHistoryPort1Entry | not-accessible | current | Row definition for the pm200frs02PerfTelecomBerLinePreFecPast15StatHistory table |
| 1.3.6.1.4.1.20044.90.11.7.353.1.1 | Columnpm200frs02PerfTelecomBerLinePreFecPast15StatHistoryPort1Index | read-only | current | Index definition for the pm200frs02PerfTelecomBerLinePreFecPast15StatHistory table |
| 1.3.6.1.4.1.20044.90.11.7.353.1.2 | Columnpm200frs02PerfTelecomBerLinePreFecPast15StatHistoryInvBerPort1 | read-only | current | Previous 15-min BER counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.353.1.3 | Columnpm200frs02PerfTelecomBerLinePreFecPast15StatHistoryBerValuePort1 | read-only | current | Previous 15-min BER counter :This OID gives the previous 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.90.11.7.353.1.4 | Columnpm200frs02PerfTelecomBerLinePreFecPast15StatHistoryInvMinBerPort1 | read-only | current | Previous 15-min MinBER counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.353.1.5 | Columnpm200frs02PerfTelecomBerLinePreFecPast15StatHistoryMinBerValuePort1 | read-only | current | Previous 15-min MinBER counter :This OID gives the previous 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.90.11.7.353.1.6 | Columnpm200frs02PerfTelecomBerLinePreFecPast15StatHistoryInvMaxBerPort1 | read-only | current | Previous 15-min MaxBER counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.353.1.7 | Columnpm200frs02PerfTelecomBerLinePreFecPast15StatHistoryMaxBerValuePort1 | read-only | current | Previous 15-min MaxBER counter :This OID gives the previous 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.90.11.7.354 | Tablepm200frs02PerfTelecomBerLinePreFecCurrent24StatTable | not-accessible | current | List of pm200frs02PerfTelecomBerLinePreFecCurrent24Stat Article |
| 1.3.6.1.4.1.20044.90.11.7.354.1 | Rowpm200frs02PerfTelecomBerLinePreFecCurrent24StatEntry | not-accessible | current | Row definition for the pm200frs02PerfTelecomBerLinePreFecCurrent24Stat table |
| 1.3.6.1.4.1.20044.90.11.7.354.1.1 | Columnpm200frs02PerfTelecomBerLinePreFecCurrent24StatIndex | read-only | current | Index definition for the pm200frs02PerfTelecomBerLinePreFecCurrent24Stat table |
| 1.3.6.1.4.1.20044.90.11.7.354.1.2 | Columnpm200frs02PerfTelecomBerLinePreFecCurrent24StatInvBerPortn | read-only | current | Current 24-hours BER counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.354.1.3 | Columnpm200frs02PerfTelecomBerLinePreFecCurrent24StatBerValuePortn | read-only | current | Current 24-hours BER counter :This OID gives the current 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.90.11.7.354.1.4 | Columnpm200frs02PerfTelecomBerLinePreFecCurrent24StatInvMinBerPortn | read-only | current | Current 24-hoursMinBER counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.354.1.5 | Columnpm200frs02PerfTelecomBerLinePreFecCurrent24StatMinBerValuePortn | read-only | current | Current 24-hours MinBER counter :This OID gives the current 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.90.11.7.354.1.6 | Columnpm200frs02PerfTelecomBerLinePreFecCurrent24StatInvMaxBerPortn | read-only | current | Current 24-hours MaxBER counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.354.1.7 | Columnpm200frs02PerfTelecomBerLinePreFecCurrent24StatMaxBerValuePortn | read-only | current | Current 24-hours MaxBER counter :This OID gives the current 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.90.11.7.355 | Tablepm200frs02PerfTelecomBerLinePreFecPast24StatHistoryPort1Table | not-accessible | current | List of pm200frs02PerfTelecomBerLinePreFecPast24StatHistory Article |
| 1.3.6.1.4.1.20044.90.11.7.355.1 | Rowpm200frs02PerfTelecomBerLinePreFecPast24StatHistoryPort1Entry | not-accessible | current | Row definition for the pm200frs02PerfTelecomBerLinePreFecPast24StatHistory table |
| 1.3.6.1.4.1.20044.90.11.7.355.1.1 | Columnpm200frs02PerfTelecomBerLinePreFecPast24StatHistoryPort1Index | read-only | current | Index definition for the pm200frs02PerfTelecomBerLinePreFecPast24StatHistory table |
| 1.3.6.1.4.1.20044.90.11.7.355.1.2 | Columnpm200frs02PerfTelecomBerLinePreFecPast24StatHistoryInvBerPort1 | read-only | current | Previous 24-hours BER counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.355.1.3 | Columnpm200frs02PerfTelecomBerLinePreFecPast24StatHistoryBerValuePort1 | read-only | current | Previous 24-hours BER counter :This OID gives the previous 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.90.11.7.355.1.4 | Columnpm200frs02PerfTelecomBerLinePreFecPast24StatHistoryInvMinBerPort1 | read-only | current | Previous 24-hours MinBER counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.355.1.5 | Columnpm200frs02PerfTelecomBerLinePreFecPast24StatHistoryMinBerValuePort1 | read-only | current | Previous 24-hours MinBER counter :This OID gives the previous 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.90.11.7.355.1.6 | Columnpm200frs02PerfTelecomBerLinePreFecPast24StatHistoryInvMaxBerPort1 | read-only | current | Previous 24-hours MaxBER counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.90.11.7.355.1.7 | Columnpm200frs02PerfTelecomBerLinePreFecPast24StatHistoryMaxBerValuePort1 | read-only | current | Previous 24-hours MaxBER counter :This OID gives the previous 24-hours severely Errored Second counter value |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| Pm200frs02AdjustValue | INTEGER { otxadjustvalue0(0), otxadjustvalue1(1), otxadjustvalue2(2), otxadjustvalue3(3), otxadjustvalue4(4), otxadjustvalue5(5), otxadjustvalue6(6), otxadjustvalue7(7), otxadjustvalue8(8), otxadjustvalue9(9), otxadjustvalue10(10) } | current | Different values in Adjust mode on OTX-TLH on client and line ports |
| Pm200frs02ClientProtocol | INTEGER { protocolclientvalue0(0), protocolclientvalue1(1), protocolclientvalue2(2), protocolclientvalue3(3), protocolclientvalue4(4), protocolclientvalue5(5), protocolclientvalue6(6), protocolclientvalue7(7), protocolclientvalue8(8) } | current | Different values on the protocol on the client ports |
| Pm200frs02DccMode | INTEGER { dccNo(0), dccLine1(1), dccLine2(2) } | current | Mode for DCC |
| Pm200frs02ModuleMode | INTEGER { modulemodevalue0(0), modulemodevalue1(1), modulemodevalue2(2), modulemodevalue3(3), modulemodevalue4(4), modulemodevalue5(5) } | current | Different values on the module mode |
| Pm200frs02MultiRate | INTEGER { rate100Mhz(0), rate250Mhz(1), rate500Mhz(2), rate1Ghz(3) } | current | different rate for a client port |
| Pm200frs02OrxChannel | INTEGER | current | Channel selection on transceiver Rx line ports |
| Pm200frs02OtxChannel | INTEGER | current | Channel selection on transceiver Tx line ports |
| Pm200frs02OtxGrid | INTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50) } | current | Different grids on OTX-TLH on client and line ports |
| Pm200frs02OtxMode | INTEGER { otx80mode(1), otx60mode(2), otxadjustmode(4) } | current | Different modes on OTX-TLH on client and line ports |