MIB Viewer

EKINOPS-Pm254d-MIB

478 objects
MIB for managing Ekinops modules with PM254d software
Imported Objects
EKINOPS-MIBEkiApiState EkiMeasureType EkiMode ekinops EkiOnOff EkiProtocol EkiState
SNMPv2-SMICounter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
SNMPv2-TCDisplayString TEXTUAL-CONVENTION
OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.17IdentitymodulePm254dMIB for managing Ekinops modules with PM254d software
1.3.6.1.4.1.20044.17.2Nodepm254dalarms
1.3.6.1.4.1.20044.17.2.1Nodepm254dAlmOther
1.3.6.1.4.1.20044.17.2.1.1Nodepm254dAlmOtherNurg
1.3.6.1.4.1.20044.17.2.1.1.0Nodepm254dAlmsynthAlm0
1.3.6.1.4.1.20044.17.2.1.1.0.9Scalarpm254dAlmModGlobFailread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the PM <Condtype> MOD_GLOB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> sy…
1.3.6.1.4.1.20044.17.2.1.1.0.15Scalarpm254dAlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.17.2.1.1.0.16Scalarpm254dAlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.17.2.1.1.2Nodepm254dAlmsynthAlm2
1.3.6.1.4.1.20044.17.2.1.1.2.1Scalarpm254dAlmConfTableSaveread-onlycurrentPM Configuration Save :This OID is set during the saving of a new configuration table in the PM Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> other (1) …
1.3.6.1.4.1.20044.17.2.1.1.2.2Scalarpm254dAlmInvUploadread-onlycurrentInventory Upload :This OID is set during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> other (1) <Alarmtype> other (1) <Polarity…
1.3.6.1.4.1.20044.17.2.1.1.2.3Scalarpm254dAlmConfTableLoadread-onlycurrentPM Configuration Load :This OID is set during the loading of configuration tables in the PMs RAM. <Condtype> CONF_TABLE_LOAD <Probcause> other (1) <Alarmtype> …
1.3.6.1.4.1.20044.17.2.1.1.2.4Scalarpm254dAlmCorrelatOffread-onlycurrentNot Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> other (1) <Alarmtype> other (1) <Pol…
1.3.6.1.4.1.20044.17.2.1.1.2.5Scalarpm254dAlmMaintenanceOnread-onlycurrentMaintenance Mode :This OID indicates that the PM is in maintenance mode. <Help> This alarm indicates that the maintenance mode is enabled on the PM <Condtype> …
1.3.6.1.4.1.20044.17.2.1.2Nodepm254dAlmOtherUrg
1.3.6.1.4.1.20044.17.2.1.2.194Nodepm254dAlmmodInitFailLevel2
1.3.6.1.4.1.20044.17.2.1.2.194.1Scalarpm254dAlmLedFailread-onlycurrentLed Fail :This OID indicates that Led register has not been correctly initalized <Help> This alarm indicates if the module LEDs are correctly initialized <Cond…
1.3.6.1.4.1.20044.17.2.1.2.194.2Scalarpm254dAlmNextColdBootForcedread-onlycurrentNext Cold Boot Forced :This OID indicates that the next Reset will be forced Cold <Help> This alarm indicates that the next reset of the module will be forced …
1.3.6.1.4.1.20044.17.2.1.2.194.3Scalarpm254dAlmBootUndoneread-onlycurrentBoot Undone :This OID indicates that the boot has not been correctly achieved <Help> This alarm indicates if the module has correctly boot <Condtype> BOOT_UNDO…
1.3.6.1.4.1.20044.17.2.1.2.194.4Scalarpm254dAlmResetHwInitFailread-onlycurrentReset HW Init Fail :This OID indicates that the HW intialization has caused unknown intial conditions <Help> This alarm indicates if the HW has been correctly …
1.3.6.1.4.1.20044.17.2.1.2.194.5Scalarpm254dAlmSwInitFailread-onlycurrentSW Init Fail :This OID indicates that the SW intialization has caused unknown intial conditions <Help> This alarm indicates if the SW module is correctly initi…
1.3.6.1.4.1.20044.17.2.1.2.195Nodepm254dAlmmodInitFailLevel3
1.3.6.1.4.1.20044.17.2.1.2.195.1Scalarpm254dAlmGwIdentFailread-onlycurrentGW Ident Fail :This OID indicates that GW identification has not been read <Help> This alarm indicates if the GW has been correctly identified <Condtype> GW_ID…
1.3.6.1.4.1.20044.17.2.1.2.195.2Scalarpm254dAlmObmTypeReadFailread-onlycurrentOBM Type Read Fail :This OID indicates that OBM type has not been recognized <Help> This alarm indicates if the OBM board has been correctly identified <Condty…
1.3.6.1.4.1.20044.17.2.1.2.195.3Scalarpm254dAlmInitModuleFailread-onlycurrentInit Module Fail :This OID indicates that the Module has not been correctly initialized <Help> This alarm indicates if the SW module is correctly initialized <…
1.3.6.1.4.1.20044.17.2.1.2.195.5Scalarpm254dAlmSfp1InitFailread-onlycurrentSFP1 Init Fail :This OID indicates that the SFP has not been correctly initialized <Help> This alarm indicates if the line transceiver 1 is correctly initializ…
1.3.6.1.4.1.20044.17.2.1.2.195.6Scalarpm254dAlmSfp2InitFailread-onlycurrentSFP2 Init Fail :This OID indicates that the SFP has not been correctly initialized <Help> This alarm indicates if the line transceiver 2 is correctly initializ…
1.3.6.1.4.1.20044.17.2.1.2.195.7Scalarpm254dAlmLine1InitFailread-onlycurrentLine1 Init Fail :This OID indicates that the Line registersvsubset has not been correctly initialized <Help> This alarm indicates if the line port 1 is correct…
1.3.6.1.4.1.20044.17.2.1.2.195.8Scalarpm254dAlmLine2InitFailread-onlycurrentLine2 Init Fail :This OID indicates that the Line register subset has not been correctly initialized <Help> This alarm indicates if the line port 2 is correctl…
1.3.6.1.4.1.20044.17.2.1.2.195.9Scalarpm254dAlmClient1InitFailread-onlycurrentClient1 Init Fail :This OID indicates that Client 1 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 1 is cor…
1.3.6.1.4.1.20044.17.2.1.2.195.10Scalarpm254dAlmClient2InitFailread-onlycurrentClient2 Init Fail :This OID indicates that Client 2 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 2 is cor…
1.3.6.1.4.1.20044.17.2.1.2.195.11Scalarpm254dAlmClient3InitFailread-onlycurrentClient3 Init Fail :This OID indicates that Client 3 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 3 is cor…
1.3.6.1.4.1.20044.17.2.1.2.195.12Scalarpm254dAlmClient4InitFailread-onlycurrentClient4 Init Fail :This OID indicates that Client 4 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 4 is cor…
1.3.6.1.4.1.20044.17.2.1.3Nodepm254dAlmOtherCrit
1.3.6.1.4.1.20044.17.2.2Nodepm254dAlmPort
1.3.6.1.4.1.20044.17.2.2.1Nodepm254dAlmPortNurg
1.3.6.1.4.1.20044.17.2.2.1.48Tablepm254dAlmclientSfpWarnDdmTablenot-accessiblecurrentList of pm254dAlmclientSfpWarnDdm Article
1.3.6.1.4.1.20044.17.2.2.1.48.1Rowpm254dAlmclientSfpWarnDdmEntrynot-accessiblecurrentRow definition for the pm254dAlmclientSfpWarnDdm table
1.3.6.1.4.1.20044.17.2.2.1.48.1.1Columnpm254dAlmclientSfpWarnDdmIndexread-onlycurrentIndex definition for the pm254dAlmclientSfpWarnDdm table
1.3.6.1.4.1.20044.17.2.2.1.48.1.2Columnpm254dAlmClientTxPwLowWngPortnread-onlycurrentClient SFP Tx Power Low Warning :Warning indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> CL…
1.3.6.1.4.1.20044.17.2.2.1.48.1.3Columnpm254dAlmClientTxPwrHighWngPortnread-onlycurrentClient SFP Tx Power High Warning :Warning indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.17.2.2.1.48.1.4Columnpm254dAlmClientTxBiasLowWngPortnread-onlycurrentClient SFP Bias Low Warning :Warning indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.17.2.2.1.48.1.5Columnpm254dAlmClientTxBiasHighWngPortnread-onlycurrentClient SFP Bias High Warning :Warning indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.17.2.2.1.48.1.6Columnpm254dAlmClientVccLowWngPortnread-onlycurrentClient SFP Power Supply Low Warning :Warning indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.17.2.2.1.48.1.7Columnpm254dAlmClientVccHighWngPortnread-onlycurrentClient SFP Power Supply High Warning :Warning indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condty…
1.3.6.1.4.1.20044.17.2.2.1.48.1.8Columnpm254dAlmClientTempLowWngPortnread-onlycurrentClient SFP Temp Low Warning :Warning indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_…
1.3.6.1.4.1.20044.17.2.2.1.48.1.9Columnpm254dAlmClientTempHighWngPortnread-onlycurrentClient SFP Temp High Warning :Warning indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIEN…
1.3.6.1.4.1.20044.17.2.2.1.48.1.16Columnpm254dAlmClientRxPwrLowWngPortnread-onlycurrentClient SFP Rx Power Low Warning :Warning indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLI…
1.3.6.1.4.1.20044.17.2.2.1.48.1.17Columnpm254dAlmClientRxPwrHighWngPortnread-onlycurrentClient SFP Rx Power High Warning :Warning indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> C…
1.3.6.1.4.1.20044.17.2.2.2Nodepm254dAlmPortUrg
1.3.6.1.4.1.20044.17.2.2.2.32Tablepm254dAlmclientSfpAlmDdmTablenot-accessiblecurrentList of pm254dAlmclientSfpAlmDdm Article
1.3.6.1.4.1.20044.17.2.2.2.32.1Rowpm254dAlmclientSfpAlmDdmEntrynot-accessiblecurrentRow definition for the pm254dAlmclientSfpAlmDdm table
1.3.6.1.4.1.20044.17.2.2.2.32.1.1Columnpm254dAlmclientSfpAlmDdmIndexread-onlycurrentIndex definition for the pm254dAlmclientSfpAlmDdm table
1.3.6.1.4.1.20044.17.2.2.2.32.1.2Columnpm254dAlmClientTxPwrLowAlaPortnread-onlycurrentClient SFP Tx Power Low :Alarm indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_TX_PW…
1.3.6.1.4.1.20044.17.2.2.2.32.1.3Columnpm254dAlmClientTxPwrHighAlaPortnread-onlycurrentClient SFP Tx Power High :Alarm indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIENT_TX_…
1.3.6.1.4.1.20044.17.2.2.2.32.1.4Columnpm254dAlmClientTxBiasLowAlaPortnread-onlycurrentClient SFP Bias Low :Alarm indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_TX_…
1.3.6.1.4.1.20044.17.2.2.2.32.1.5Columnpm254dAlmClientTxBiasHighAlaPortnread-onlycurrentClient SFP Bias High :Alarm indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIENT_T…
1.3.6.1.4.1.20044.17.2.2.2.32.1.6Columnpm254dAlmClientVccLowAlaPortnread-onlycurrentClient SFP Power Supply Low :Alarm indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_V…
1.3.6.1.4.1.20044.17.2.2.2.32.1.7Columnpm254dAlmClientVccHighAlaPortnread-onlycurrentClient SFP Power Supply High :Alarm indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIENT…
1.3.6.1.4.1.20044.17.2.2.2.32.1.8Columnpm254dAlmClientTempLowAlaPortnread-onlycurrentClient SFP Temp Low :Alarm indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_TEMP_LOW_A…
1.3.6.1.4.1.20044.17.2.2.2.32.1.9Columnpm254dAlmClientTempHighAlaPortnread-onlycurrentClient SFP Temp High :Alarm indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIENT_TEMP_HIG…
1.3.6.1.4.1.20044.17.2.2.2.32.1.16Columnpm254dAlmClientRxPwrLowAlaPortnread-onlycurrentClient SFP Rx Power Low :Alarm indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_RX_PWR…
1.3.6.1.4.1.20044.17.2.2.2.32.1.17Columnpm254dAlmClientRxPwrHighAlaPortnread-onlycurrentClient SFP Rx Power High :Alarm indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIENT_RX_P…
1.3.6.1.4.1.20044.17.2.2.3Nodepm254dAlmPortCrit
1.3.6.1.4.1.20044.17.2.2.3.8Tablepm254dAlmsynthAlmClientTablenot-accessiblecurrentList of pm254dAlmsynthAlmClient Article
1.3.6.1.4.1.20044.17.2.2.3.8.1Rowpm254dAlmsynthAlmClientEntrynot-accessiblecurrentRow definition for the pm254dAlmsynthAlmClient table
1.3.6.1.4.1.20044.17.2.2.3.8.1.1Columnpm254dAlmsynthAlmClientIndexread-onlycurrentIndex definition for the pm254dAlmsynthAlmClient table
1.3.6.1.4.1.20044.17.2.2.3.8.1.2Columnpm254dAlmClientSfpAbsentPortnread-onlycurrentClient SFP Absent :This OID indicates that the SFP module is not present in the client port. <Help> This alarm indicates if the client transceiver is present. …
1.3.6.1.4.1.20044.17.2.2.3.8.1.3Columnpm254dAlmClientDdmAbsentPortnread-onlycurrentDDM Supported On Client SFP :This OID indicates that the Client SFP module does not support the Digital Diagnostic Monitoring function <Help> This status indic…
1.3.6.1.4.1.20044.17.2.2.3.8.1.5Columnpm254dAlmClientHwFailAccPortnread-onlycurrentClient HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Condtype> CLIENT_HW_FAIL_ACC_1 <Probcause> equipmentMalfuncti…
1.3.6.1.4.1.20044.17.2.2.3.8.1.6Columnpm254dAlmClientLsdPortnread-onlycurrentClient SFP Laser Shutdown :This OID indicates the Client SFP transmitter output has shut down. <Help> This status indicates if the client transceiver laser is …
1.3.6.1.4.1.20044.17.2.2.3.8.1.7Columnpm254dAlmClientLocalOosPortnread-onlycurrentLocal Client Port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local c…
1.3.6.1.4.1.20044.17.2.2.3.8.1.8Columnpm254dAlmClientRemoteOosPortnread-onlycurrentRemote Client Port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the remot…
1.3.6.1.4.1.20044.17.2.2.3.8.1.9Columnpm254dAlmClientDwCaisPortnread-onlycurrentClient AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indicates if a Client Alarm Indication Signal is…
1.3.6.1.4.1.20044.17.2.2.3.8.1.10Columnpm254dAlmClientSfpDdmWarningPortnread-onlycurrentWarning On Client SFP DDM :This OID indicates a warning is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Warning has been detecte…
1.3.6.1.4.1.20044.17.2.2.3.8.1.11Columnpm254dAlmClientSfpDdmAlmPortnread-onlycurrentAlarm On Client SFP DDM :This OID indicates an alarm is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Alarm has been detected on …
1.3.6.1.4.1.20044.17.2.2.3.8.1.13Columnpm254dAlmClientFailAccPortnread-onlycurrentClient Access Fail :This OID indicates a failure on the Client port <Condtype> CLIENT_FAIL_ACC_1 <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAla…
1.3.6.1.4.1.20044.17.2.2.3.8.1.17Columnpm254dAlmClientUpCsfPortnread-onlycurrentClient Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu…
1.3.6.1.4.1.20044.17.2.2.3.16Tablepm254dAlmaccessioAlmTablenot-accessiblecurrentList of pm254dAlmaccessioAlm Article
1.3.6.1.4.1.20044.17.2.2.3.16.1Rowpm254dAlmaccessioAlmEntrynot-accessiblecurrentRow definition for the pm254dAlmaccessioAlm table
1.3.6.1.4.1.20044.17.2.2.3.16.1.1Columnpm254dAlmaccessioAlmIndexread-onlycurrentIndex definition for the pm254dAlmaccessioAlm table
1.3.6.1.4.1.20044.17.2.2.3.16.1.2Columnpm254dAlmClientDwLasFailPortnread-onlycurrentClient SFP Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the client port (this alarm reports the transmitter failure alarm …
1.3.6.1.4.1.20044.17.2.2.3.16.1.5Columnpm254dAlmClientUpLosPortnread-onlycurrentClient Input Loss Of Signal :This OID indicates that no signal is present on the SFP of the client port <Help> This alarm indicates if an optical signal is det…
1.3.6.1.4.1.20044.17.2.2.3.72Tablepm254dAlmclientMapperDeAlmTablenot-accessiblecurrentList of pm254dAlmclientMapperDeAlm Article
1.3.6.1.4.1.20044.17.2.2.3.72.1Rowpm254dAlmclientMapperDeAlmEntrynot-accessiblecurrentRow definition for the pm254dAlmclientMapperDeAlm table
1.3.6.1.4.1.20044.17.2.2.3.72.1.1Columnpm254dAlmclientMapperDeAlmIndexread-onlycurrentIndex definition for the pm254dAlmclientMapperDeAlm table
1.3.6.1.4.1.20044.17.2.2.3.72.1.2Columnpm254dAlmClientUpAccOosPortnread-onlycurrentClient Loss Of 10b/8b Synchro :This OID indicates the upstream client input port has lost synchronization on its 10B/8B decoder <Help> This alarms indicates if…
1.3.6.1.4.1.20044.17.2.2.3.72.1.11Columnpm254dAlmClientUpBufferOvlPortnread-onlycurrentClient Upstream Buffer Overload :This OID indicates that the rate adaptation buffer for client port is in overload. <Help> This alarm indicates if there is a u…
1.3.6.1.4.1.20044.17.2.2.3.72.1.12Columnpm254dAlmClientDwCsfDetPortnread-onlycurrentClient Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client…
1.3.6.1.4.1.20044.17.2.2.3.72.1.15Columnpm254dAlmClientDwBufferOvlPortnread-onlycurrentClient Downstream Buffer Overload :This OID indicates that the de-mapper buffer for client port is in overload. <Help> This alarm indicates if there is a downs…
1.3.6.1.4.1.20044.17.2.2.3.72.1.16Columnpm254dAlmClientLoopAccFifoFailPortnread-onlydeprecatedClient Port Loop FIFO Failure :active only in client loopback mode. <Condtype> CLIENT_LOOP_ACC_FIFO_FAIL_1 <Probcause> equipmentMalfunction (16) <Alarmtype> eq…
1.3.6.1.4.1.20044.17.2.3Nodepm254dAlmLine
1.3.6.1.4.1.20044.17.2.3.1Nodepm254dAlmLineNurg
1.3.6.1.4.1.20044.17.2.3.1.130Tablepm254dAlmlineDownS1Tablenot-accessiblecurrentList of pm254dAlmlineDownS1 Article
1.3.6.1.4.1.20044.17.2.3.1.130.1Rowpm254dAlmlineDownS1Entrynot-accessiblecurrentRow definition for the pm254dAlmlineDownS1 table
1.3.6.1.4.1.20044.17.2.3.1.130.1.1Columnpm254dAlmlineDownS1Indexread-onlycurrentIndex definition for the pm254dAlmlineDownS1 table
1.3.6.1.4.1.20044.17.2.3.1.130.1.2Columnpm254dAlmlineDownS1Portnread-onlycurrentLine 1 S1 Extracted Value :This gives the value of S1 extracted from the overhead of the received OC-48c/STM-16c signal on the line 1 <Condtype> LINE_DW_S1_8_1…
1.3.6.1.4.1.20044.17.2.3.1.131Tablepm254dAlmlineDownK1Tablenot-accessiblecurrentList of pm254dAlmlineDownK1 Article
1.3.6.1.4.1.20044.17.2.3.1.131.1Rowpm254dAlmlineDownK1Entrynot-accessiblecurrentRow definition for the pm254dAlmlineDownK1 table
1.3.6.1.4.1.20044.17.2.3.1.131.1.1Columnpm254dAlmlineDownK1Indexread-onlycurrentIndex definition for the pm254dAlmlineDownK1 table
1.3.6.1.4.1.20044.17.2.3.1.131.1.2Columnpm254dAlmlineDownK1Portnread-onlycurrentLine 1 K1 Extracted Value :This gives the value of K1 extracted from the overhead of the received OC-48c/STM-16c signal on the line 1 <Condtype> LINE_DW_K1_8_1…
1.3.6.1.4.1.20044.17.2.3.1.132Tablepm254dAlmlineDownK2Tablenot-accessiblecurrentList of pm254dAlmlineDownK2 Article
1.3.6.1.4.1.20044.17.2.3.1.132.1Rowpm254dAlmlineDownK2Entrynot-accessiblecurrentRow definition for the pm254dAlmlineDownK2 table
1.3.6.1.4.1.20044.17.2.3.1.132.1.1Columnpm254dAlmlineDownK2Indexread-onlycurrentIndex definition for the pm254dAlmlineDownK2 table
1.3.6.1.4.1.20044.17.2.3.1.132.1.2Columnpm254dAlmlineDownK2Portnread-onlycurrentLine 1 K2 Extracted Value :This gives the value of K2 extracted from the overhead of the received OC-48c/STM-16c signal on the line 1 <Condtype> LINE_DW_K2_8_1…
1.3.6.1.4.1.20044.17.2.3.1.164Tablepm254dAlmlineSfpWarnDdmTablenot-accessiblecurrentList of pm254dAlmlineSfpWarnDdm Article
1.3.6.1.4.1.20044.17.2.3.1.164.1Rowpm254dAlmlineSfpWarnDdmEntrynot-accessiblecurrentRow definition for the pm254dAlmlineSfpWarnDdm table
1.3.6.1.4.1.20044.17.2.3.1.164.1.1Columnpm254dAlmlineSfpWarnDdmIndexread-onlycurrentIndex definition for the pm254dAlmlineSfpWarnDdm table
1.3.6.1.4.1.20044.17.2.3.1.164.1.2Columnpm254dAlmLineTxPwLowWngPortnread-onlycurrentLine SFP Tx Power Low Warning :Warning indicating that the SFP output power of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE…
1.3.6.1.4.1.20044.17.2.3.1.164.1.3Columnpm254dAlmLineTxPwrHighWngPortnread-onlycurrentLine SFP Tx Power High Warning :Warning indicating that the SFP output power of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LI…
1.3.6.1.4.1.20044.17.2.3.1.164.1.4Columnpm254dAlmLineTxBiasLowWngPortnread-onlycurrentLine SFP Bias Low Warning :Warning indicating that the SFP laser bias current of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LI…
1.3.6.1.4.1.20044.17.2.3.1.164.1.5Columnpm254dAlmLineTxBiasHighWngPortnread-onlycurrentLine SFP Bias High Warning :Warning indicating that the SFP laser bias current of Line is higher than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.17.2.3.1.164.1.6Columnpm254dAlmLineVccLowWngPortnread-onlycurrentLine SFP Power Supply Low Warning :Warning indicating that the SFP power supply of Line is lower than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.17.2.3.1.164.1.7Columnpm254dAlmLineVccHighWngPortnread-onlycurrentLine SFP Power Supply High Warning :Warning indicating that the SFP power supply of Line is higher than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.17.2.3.1.164.1.8Columnpm254dAlmLineTempLowWngPortnread-onlycurrentLine SFP Temp Low Warning :Warning indicating that the SFP temperature of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_TEMP…
1.3.6.1.4.1.20044.17.2.3.1.164.1.9Columnpm254dAlmLineTempHighWngPortnread-onlycurrentLine SFP Temp High Warning :Warning indicating that the SFP temperature of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_TE…
1.3.6.1.4.1.20044.17.2.3.1.164.1.16Columnpm254dAlmLineRxPwrLowWngPortnread-onlycurrentLine SFP Rx Power Low Warning :Warning indicating that the SFP input power of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_…
1.3.6.1.4.1.20044.17.2.3.1.164.1.17Columnpm254dAlmLineRxPwrHighWngPortnread-onlycurrentLine SFP Rx Power High Warning :Warning indicating that the SFP input power of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LIN…
1.3.6.1.4.1.20044.17.2.3.2Nodepm254dAlmLineUrg
1.3.6.1.4.1.20044.17.2.3.2.162Tablepm254dAlmlineSfpAlaDdmTablenot-accessiblecurrentList of pm254dAlmlineSfpAlaDdm Article
1.3.6.1.4.1.20044.17.2.3.2.162.1Rowpm254dAlmlineSfpAlaDdmEntrynot-accessiblecurrentRow definition for the pm254dAlmlineSfpAlaDdm table
1.3.6.1.4.1.20044.17.2.3.2.162.1.1Columnpm254dAlmlineSfpAlaDdmIndexread-onlycurrentIndex definition for the pm254dAlmlineSfpAlaDdm table
1.3.6.1.4.1.20044.17.2.3.2.162.1.2Columnpm254dAlmLineTxPwrLowAlaPortnread-onlycurrentLine SFP Tx Power Low :Alarm indicating that the SFP output power of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_TX_PWR_LO…
1.3.6.1.4.1.20044.17.2.3.2.162.1.3Columnpm254dAlmLineTxPwrHighAlaPortnread-onlycurrentLine SFP Tx Power High :Alarm indicating that the SFP output power of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_TX_PWR_…
1.3.6.1.4.1.20044.17.2.3.2.162.1.4Columnpm254dAlmLineTxBiasLowAlaPortnread-onlycurrentLine SFP Bias Low :Alarm indicating that the SFP laser bias current of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_TX_BIAS…
1.3.6.1.4.1.20044.17.2.3.2.162.1.5Columnpm254dAlmLineTxBiasHighAlaPortnread-onlycurrentLine SFP Bias High :Alarm indicating that the SFP laser bias current of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_TX_BI…
1.3.6.1.4.1.20044.17.2.3.2.162.1.6Columnpm254dAlmLineVccLowAlaPortnread-onlycurrentLine SFP Power Supply Low :Alarm indicating that the SFP power supply of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_VCC_L…
1.3.6.1.4.1.20044.17.2.3.2.162.1.7Columnpm254dAlmLineVccHighAlaPortnread-onlycurrentLine SFP Power Supply High :Alarm indicating that the SFP power supply of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_VCC…
1.3.6.1.4.1.20044.17.2.3.2.162.1.8Columnpm254dAlmLineTempLowAlaPortnread-onlycurrentLine SFP Temp Low :Alarm indicating that the SFP temperature of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_TEMP_LOW_ALA_1…
1.3.6.1.4.1.20044.17.2.3.2.162.1.9Columnpm254dAlmLineTempHighAlaPortnread-onlycurrentLine SFP Temp High :Alarm indicating that the SFP temperature of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_TEMP_HIGH_AL…
1.3.6.1.4.1.20044.17.2.3.2.162.1.16Columnpm254dAlmLineRxPwrLowAlaPortnread-onlycurrentLine SFP Rx Power Low :Alarm indicating that the SFP input power of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_RX_PWR_LOW…
1.3.6.1.4.1.20044.17.2.3.2.162.1.17Columnpm254dAlmLineRxPwrHighAlaPortnread-onlycurrentLine SFP Rx Power High :Alarm indicating that the SFP input power of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_RX_PWR_H…
1.3.6.1.4.1.20044.17.2.3.3Nodepm254dAlmLineCrit
1.3.6.1.4.1.20044.17.2.3.3.5Tablepm254dAlmsynthAlmLineTablenot-accessiblecurrentList of pm254dAlmsynthAlmLine Article
1.3.6.1.4.1.20044.17.2.3.3.5.1Rowpm254dAlmsynthAlmLineEntrynot-accessiblecurrentRow definition for the pm254dAlmsynthAlmLine table
1.3.6.1.4.1.20044.17.2.3.3.5.1.1Columnpm254dAlmsynthAlmLineIndexread-onlycurrentIndex definition for the pm254dAlmsynthAlmLine table
1.3.6.1.4.1.20044.17.2.3.3.5.1.2Columnpm254dAlmLineSfpAbsentPortnread-onlycurrentLine SFP Absent :This OID indicates that the SFP module is not present in the line port. <Help> This alarm indicates if the line transceiver is present. <Condt…
1.3.6.1.4.1.20044.17.2.3.3.5.1.3Columnpm254dAlmLineDdmAbsentPortnread-onlycurrentDDM Supported On Line SFP :This OID indicates that the SFP module on line port does not support Digital Diagnostic Monitoring Functions <Help> This status indi…
1.3.6.1.4.1.20044.17.2.3.3.5.1.5Columnpm254dAlmLineHwFailPortnread-onlycurrentLine HW Fail :This OID indicates a failure condition on the Line port, the most probable cause being a HW issue <Condtype> LINE_HW_FAIL_1 <Probcause> equipment…
1.3.6.1.4.1.20044.17.2.3.3.5.1.6Columnpm254dAlmLineLsdPortnread-onlycurrentLine SFP Laser Shutdown :This OID indicates the SFP transmitter line output is shut down. <Help> This status indicates if the line transceiver laser is ON or O…
1.3.6.1.4.1.20044.17.2.3.3.5.1.7Columnpm254dAlmLineLocalOosPortnread-onlycurrentLine Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service…
1.3.6.1.4.1.20044.17.2.3.3.5.1.9Columnpm254dAlmLineUpRdiInsPortnread-onlycurrentMS-RDI/L-RDI Inserted On Line :This OID indicates an upstream MS-RDI/L-RDI has been inserted on the outgoing 2.5 Gb/s SDH/SONET signal. <Help> This status indi…
1.3.6.1.4.1.20044.17.2.3.3.5.1.10Columnpm254dAlmLineDdmWarningPortnread-onlycurrentWarning On Line SFP DDM :This OID indicates a warning is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Warning has been…
1.3.6.1.4.1.20044.17.2.3.3.5.1.11Columnpm254dAlmLineDdmAlmPortnread-onlycurrentAlarm On Line SFP DDM :This OID indicates an alarm is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Alarm has been dete…
1.3.6.1.4.1.20044.17.2.3.3.5.1.13Columnpm254dAlmLineFailPortnread-onlycurrentLine Fail :This OID indicates a failure condition on the Line. <Condtype> LINE_FAIL_1 <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12) <Po…
1.3.6.1.4.1.20044.17.2.3.3.5.1.17Columnpm254dAlmDccActivePortnread-onlycurrentDCC Active :This OID indicates the DCC is active on receive side <Help> This status indicates whether the DCC is active or standby on this line <Condtype> DCC_…
1.3.6.1.4.1.20044.17.2.3.3.128Tablepm254dAlmlineDfrmAlmTablenot-accessiblecurrentList of pm254dAlmlineDfrmAlm Article
1.3.6.1.4.1.20044.17.2.3.3.128.1Rowpm254dAlmlineDfrmAlmEntrynot-accessiblecurrentRow definition for the pm254dAlmlineDfrmAlm table
1.3.6.1.4.1.20044.17.2.3.3.128.1.1Columnpm254dAlmlineDfrmAlmIndexread-onlycurrentIndex definition for the pm254dAlmlineDfrmAlm table
1.3.6.1.4.1.20044.17.2.3.3.128.1.2Columnpm254dAlmLineDwAisDetPortnread-onlycurrentMS-AIS/L-AIS Detected On Line Input :This OID indicates that an MS-AIS has been detected on incoming OC-48c/STM-16c input signal <Help> This alarm indicates if…
1.3.6.1.4.1.20044.17.2.3.3.128.1.3Columnpm254dAlmLineDwRdiDetPortnread-onlycurrentMS-RDI/L-RDI Detected On Line Input :This OID indicates that an MS-RDI has been detected on incoming OC-48c/STM-16c input signal <Help> This alarm indicates if…
1.3.6.1.4.1.20044.17.2.3.3.128.1.4Columnpm254dAlmLineDwOofPortnread-onlycurrentSONET/SDH Line Out Of Frame :This OID indicates that an Out Of Frame has been detected on incoming OC-48c/STM-16c input signal <Help> This alarm indicates if t…
1.3.6.1.4.1.20044.17.2.3.3.128.1.5Columnpm254dAlmLineDwLofPortnread-onlycurrentSONET/SDH Line Loss Of Frame :This OID indicates that a Loss Of Frame has been detected on incoming OC-48c/STM-16c input signal <Help> This alarm indicates if …
1.3.6.1.4.1.20044.17.2.3.3.128.1.10Columnpm254dAlmDwLopPortnread-onlycurrentP-LOP On STS48c :This OID indicates that a Loss Of Pointer has been detected on incoming STS-48c input signal <Help> This alarm indicates if Loss of Pointer is…
1.3.6.1.4.1.20044.17.2.3.3.128.1.11Columnpm254dAlmDwAuAisPortnread-onlycurrentP-AIS On STS48c :This OID indicates that an AU-AIS/AIS-P has been detected on incoming STS-48c input signal <Help> This alarm indicates if a Path AIS is detect…
1.3.6.1.4.1.20044.17.2.3.3.160Tablepm254dAlmlineIoAlmTablenot-accessiblecurrentList of pm254dAlmlineIoAlm Article
1.3.6.1.4.1.20044.17.2.3.3.160.1Rowpm254dAlmlineIoAlmEntrynot-accessiblecurrentRow definition for the pm254dAlmlineIoAlm table
1.3.6.1.4.1.20044.17.2.3.3.160.1.1Columnpm254dAlmlineIoAlmIndexread-onlycurrentIndex definition for the pm254dAlmlineIoAlm table
1.3.6.1.4.1.20044.17.2.3.3.160.1.2Columnpm254dAlmLineUpLasFailPortnread-onlycurrentLine SFP Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the line port #n (this alarm reports the transmitter failure alarm g…
1.3.6.1.4.1.20044.17.2.3.3.160.1.5Columnpm254dAlmLineDwLosPortnread-onlycurrentLine Input Loss Of Signal :This OID indicates that no signal is present on the SFP of the line port #n <Help> This alarm indicates if an optical signal is dete…
1.3.6.1.4.1.20044.17.3Nodepm254dmeasures
1.3.6.1.4.1.20044.17.3.1Nodepm254dMesrOther
1.3.6.1.4.1.20044.17.3.2Nodepm254dMesrPort
1.3.6.1.4.1.20044.17.3.2.16Tablepm254dMesrclientTempMeasTablenot-accessiblecurrentList of pm254dMesrclientTempMeas Article
1.3.6.1.4.1.20044.17.3.2.16.1Rowpm254dMesrclientTempMeasEntrynot-accessiblecurrentRow definition for the pm254dMesrclientTempMeas table
1.3.6.1.4.1.20044.17.3.2.16.1.1Columnpm254dMesrclientTempMeasIndexread-onlycurrentIndex definition for the pm254dMesrclientTempMeas table
1.3.6.1.4.1.20044.17.3.2.16.1.2Columnpm254dMesrclientTempMeasPortnread-onlycurrentClient SFP Temperature :This OID gives the temperature value of the client SFP, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit …
1.3.6.1.4.1.20044.17.3.2.24Tablepm254dMesrclientVoltMeasTablenot-accessiblecurrentList of pm254dMesrclientVoltMeas Article
1.3.6.1.4.1.20044.17.3.2.24.1Rowpm254dMesrclientVoltMeasEntrynot-accessiblecurrentRow definition for the pm254dMesrclientVoltMeas table
1.3.6.1.4.1.20044.17.3.2.24.1.1Columnpm254dMesrclientVoltMeasIndexread-onlycurrentIndex definition for the pm254dMesrclientVoltMeas table
1.3.6.1.4.1.20044.17.3.2.24.1.2Columnpm254dMesrclientVoltMeasPortnread-onlycurrentClient SFP Power Supply :This OID gives the 3V3 voltage value of the client SFP, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/10000) (Unit =…
1.3.6.1.4.1.20044.17.3.2.32Tablepm254dMesrclientBiasMeasTablenot-accessiblecurrentList of pm254dMesrclientBiasMeas Article
1.3.6.1.4.1.20044.17.3.2.32.1Rowpm254dMesrclientBiasMeasEntrynot-accessiblecurrentRow definition for the pm254dMesrclientBiasMeas table
1.3.6.1.4.1.20044.17.3.2.32.1.1Columnpm254dMesrclientBiasMeasIndexread-onlycurrentIndex definition for the pm254dMesrclientBiasMeas table
1.3.6.1.4.1.20044.17.3.2.32.1.2Columnpm254dMesrclientBiasMeasPortnread-onlycurrentClient SFP Laser Bias :This OID gives the bias value of the Client SFP, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <Help> Th…
1.3.6.1.4.1.20044.17.3.2.40Tablepm254dMesrclientTxpwrMeasTablenot-accessiblecurrentList of pm254dMesrclientTxpwrMeas Article
1.3.6.1.4.1.20044.17.3.2.40.1Rowpm254dMesrclientTxpwrMeasEntrynot-accessiblecurrentRow definition for the pm254dMesrclientTxpwrMeas table
1.3.6.1.4.1.20044.17.3.2.40.1.1Columnpm254dMesrclientTxpwrMeasIndexread-onlycurrentIndex definition for the pm254dMesrclientTxpwrMeas table
1.3.6.1.4.1.20044.17.3.2.40.1.2Columnpm254dMesrclientTxpwrMeasPortnread-onlycurrentClient SFP Tx Power :This OID gives the transmit power value of the Client SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit…
1.3.6.1.4.1.20044.17.3.2.48Tablepm254dMesrclientRxpwrMeasTablenot-accessiblecurrentList of pm254dMesrclientRxpwrMeas Article
1.3.6.1.4.1.20044.17.3.2.48.1Rowpm254dMesrclientRxpwrMeasEntrynot-accessiblecurrentRow definition for the pm254dMesrclientRxpwrMeas table
1.3.6.1.4.1.20044.17.3.2.48.1.1Columnpm254dMesrclientRxpwrMeasIndexread-onlycurrentIndex definition for the pm254dMesrclientRxpwrMeas table
1.3.6.1.4.1.20044.17.3.2.48.1.2Columnpm254dMesrclientRxpwrMeasPortnread-onlycurrentClient SFP Rx Power :This OID gives the receive power value of the Client SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = …
1.3.6.1.4.1.20044.17.3.3Nodepm254dMesrLine
1.3.6.1.4.1.20044.17.3.3.160Tablepm254dMesrlineTempMeasTablenot-accessiblecurrentList of pm254dMesrlineTempMeas Article
1.3.6.1.4.1.20044.17.3.3.160.1Rowpm254dMesrlineTempMeasEntrynot-accessiblecurrentRow definition for the pm254dMesrlineTempMeas table
1.3.6.1.4.1.20044.17.3.3.160.1.1Columnpm254dMesrlineTempMeasIndexread-onlycurrentIndex definition for the pm254dMesrlineTempMeas table
1.3.6.1.4.1.20044.17.3.3.160.1.2Columnpm254dMesrlineTempMeasPortnread-onlycurrentLine SFP Temperature :This OID gives the temperature value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit = C)…
1.3.6.1.4.1.20044.17.3.3.161Tablepm254dMesrlineVoltMeasTablenot-accessiblecurrentList of pm254dMesrlineVoltMeas Article
1.3.6.1.4.1.20044.17.3.3.161.1Rowpm254dMesrlineVoltMeasEntrynot-accessiblecurrentRow definition for the pm254dMesrlineVoltMeas table
1.3.6.1.4.1.20044.17.3.3.161.1.1Columnpm254dMesrlineVoltMeasIndexread-onlycurrentIndex definition for the pm254dMesrlineVoltMeas table
1.3.6.1.4.1.20044.17.3.3.161.1.2Columnpm254dMesrlineVoltMeasPortnread-onlycurrentLine SFP Power Supply :This OID gives the 3V3 voltage value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/10000) (Unit = V) …
1.3.6.1.4.1.20044.17.3.3.162Tablepm254dMesrlineBiasMeasTablenot-accessiblecurrentList of pm254dMesrlineBiasMeas Article
1.3.6.1.4.1.20044.17.3.3.162.1Rowpm254dMesrlineBiasMeasEntrynot-accessiblecurrentRow definition for the pm254dMesrlineBiasMeas table
1.3.6.1.4.1.20044.17.3.3.162.1.1Columnpm254dMesrlineBiasMeasIndexread-onlycurrentIndex definition for the pm254dMesrlineBiasMeas table
1.3.6.1.4.1.20044.17.3.3.162.1.2Columnpm254dMesrlineBiasMeasPortnread-onlycurrentLine SFP Laser Bias :This OID gives the bias value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <Help> This m…
1.3.6.1.4.1.20044.17.3.3.163Tablepm254dMesrlineTxpwrMeasTablenot-accessiblecurrentList of pm254dMesrlineTxpwrMeas Article
1.3.6.1.4.1.20044.17.3.3.163.1Rowpm254dMesrlineTxpwrMeasEntrynot-accessiblecurrentRow definition for the pm254dMesrlineTxpwrMeas table
1.3.6.1.4.1.20044.17.3.3.163.1.1Columnpm254dMesrlineTxpwrMeasIndexread-onlycurrentIndex definition for the pm254dMesrlineTxpwrMeas table
1.3.6.1.4.1.20044.17.3.3.163.1.2Columnpm254dMesrlineTxpwrMeasPortnread-onlycurrentLine SFP Tx Power :This OID gives the transmit power value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = d…
1.3.6.1.4.1.20044.17.3.3.164Tablepm254dMesrlineRxpwrMeasTablenot-accessiblecurrentList of pm254dMesrlineRxpwrMeas Article
1.3.6.1.4.1.20044.17.3.3.164.1Rowpm254dMesrlineRxpwrMeasEntrynot-accessiblecurrentRow definition for the pm254dMesrlineRxpwrMeas table
1.3.6.1.4.1.20044.17.3.3.164.1.1Columnpm254dMesrlineRxpwrMeasIndexread-onlycurrentIndex definition for the pm254dMesrlineRxpwrMeas table
1.3.6.1.4.1.20044.17.3.3.164.1.2Columnpm254dMesrlineRxpwrMeasPortnread-onlycurrentLine SFP Rx Power :This OID gives the receive power value of the Line SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm)…
1.3.6.1.4.1.20044.17.4Nodepm254dcounters
1.3.6.1.4.1.20044.17.4.1Nodepm254dCntOther
1.3.6.1.4.1.20044.17.4.2Nodepm254dCntPort
1.3.6.1.4.1.20044.17.4.2.16Tablepm254dCntclientUpRaRemCntTablenot-accessiblecurrentList of pm254dCntclientUpRaRemCnt Article
1.3.6.1.4.1.20044.17.4.2.16.1Rowpm254dCntclientUpRaRemCntEntrynot-accessiblecurrentRow definition for the pm254dCntclientUpRaRemCnt table
1.3.6.1.4.1.20044.17.4.2.16.1.1Columnpm254dCntclientUpRaRemCntIndexread-onlycurrentIndex definition for the pm254dCntclientUpRaRemCnt table
1.3.6.1.4.1.20044.17.4.2.16.1.2Columnpm254dCntclientUpRaRemCntValuePortnread-onlycurrentClient Rate Adapt. Words Removal :This counter is incremented each time a rate adaptation 10B word is removed from the Client input stream
1.3.6.1.4.1.20044.17.4.2.16.1.3Columnpm254dCntclientUpRaRemCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the rate adaptation removal counter value is invalid on Port
1.3.6.1.4.1.20044.17.4.2.16.1.4Columnpm254dCntclientUpRaRemCntOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a rate adaptation removal counter overload on Port
1.3.6.1.4.1.20044.17.4.2.24Tablepm254dCntclientUpRaInsCntTablenot-accessiblecurrentList of pm254dCntclientUpRaInsCnt Article
1.3.6.1.4.1.20044.17.4.2.24.1Rowpm254dCntclientUpRaInsCntEntrynot-accessiblecurrentRow definition for the pm254dCntclientUpRaInsCnt table
1.3.6.1.4.1.20044.17.4.2.24.1.1Columnpm254dCntclientUpRaInsCntIndexread-onlycurrentIndex definition for the pm254dCntclientUpRaInsCnt table
1.3.6.1.4.1.20044.17.4.2.24.1.2Columnpm254dCntclientUpRaInsCntValuePortnread-onlycurrentClient Rate Adapt. Words Insertion :This counter is incremented each time a rate adaptation 10B word is inserted in the Client input stream
1.3.6.1.4.1.20044.17.4.2.24.1.3Columnpm254dCntclientUpRaInsCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the rate adaptation insertion counter value is invalid on Port
1.3.6.1.4.1.20044.17.4.2.24.1.4Columnpm254dCntclientUpRaInsCntOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a rate adaptation insertion counter overload on Port
1.3.6.1.4.1.20044.17.4.2.32Tablepm254dCntclientUpDispErrCntTablenot-accessiblecurrentList of pm254dCntclientUpDispErrCnt Article
1.3.6.1.4.1.20044.17.4.2.32.1Rowpm254dCntclientUpDispErrCntEntrynot-accessiblecurrentRow definition for the pm254dCntclientUpDispErrCnt table
1.3.6.1.4.1.20044.17.4.2.32.1.1Columnpm254dCntclientUpDispErrCntIndexread-onlycurrentIndex definition for the pm254dCntclientUpDispErrCnt table
1.3.6.1.4.1.20044.17.4.2.32.1.2Columnpm254dCntclientUpDispErrCntValuePortnread-onlycurrentClient Input Errors :This counter is incremented each time a running disparity error or a 10b/8b decoding violation is detected on the Client input stream <Hel…
1.3.6.1.4.1.20044.17.4.2.32.1.3Columnpm254dCntclientUpDispErrCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the 10B/8B decoding violations counter value is invalid on Port
1.3.6.1.4.1.20044.17.4.2.32.1.4Columnpm254dCntclientUpDispErrCntOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a 10B/8B decoding violations counter overload on Port
1.3.6.1.4.1.20044.17.4.2.40Tablepm254dCntclientUpTimCntTablenot-accessiblecurrentList of pm254dCntclientUpTimCnt Article
1.3.6.1.4.1.20044.17.4.2.40.1Rowpm254dCntclientUpTimCntEntrynot-accessiblecurrentRow definition for the pm254dCntclientUpTimCnt table
1.3.6.1.4.1.20044.17.4.2.40.1.1Columnpm254dCntclientUpTimCntIndexread-onlycurrentIndex definition for the pm254dCntclientUpTimCnt table
1.3.6.1.4.1.20044.17.4.2.40.1.2Columnpm254dCntclientUpTimCntValuePortnread-onlycurrentClient Upstream Timer Counter :This is the timing counter dedicated to the upstream access counters. It is incremented every 125 us.
1.3.6.1.4.1.20044.17.4.2.40.1.3Columnpm254dCntclientUpTimCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the upstream timing counter value is invalid on Port
1.3.6.1.4.1.20044.17.4.2.40.1.4Columnpm254dCntclientUpTimCntOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a upstream timing counter overload on Port
1.3.6.1.4.1.20044.17.4.2.64Tablepm254dCntclientDwCbipCntTablenot-accessiblecurrentList of pm254dCntclientDwCbipCnt Article
1.3.6.1.4.1.20044.17.4.2.64.1Rowpm254dCntclientDwCbipCntEntrynot-accessiblecurrentRow definition for the pm254dCntclientDwCbipCnt table
1.3.6.1.4.1.20044.17.4.2.64.1.1Columnpm254dCntclientDwCbipCntIndexread-onlycurrentIndex definition for the pm254dCntclientDwCbipCnt table
1.3.6.1.4.1.20044.17.4.2.64.1.2Columnpm254dCntclientDwCbipCntValuePortnread-onlycurrentClient CBIP Errors :This counter is incremented each time a CBIP parity error is detected on the Client output stream <Help> This counter gives the number of C…
1.3.6.1.4.1.20044.17.4.2.64.1.3Columnpm254dCntclientDwCbipCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the CBIP error counter value is invalid on Port
1.3.6.1.4.1.20044.17.4.2.64.1.4Columnpm254dCntclientDwCbipCntOverloadPortnread-onlycurrentClient CBIP Counter Overload :This OID when set indicates a CBIP error counter overload on Port
1.3.6.1.4.1.20044.17.4.2.72Tablepm254dCntclientDwTimCntTablenot-accessiblecurrentList of pm254dCntclientDwTimCnt Article
1.3.6.1.4.1.20044.17.4.2.72.1Rowpm254dCntclientDwTimCntEntrynot-accessiblecurrentRow definition for the pm254dCntclientDwTimCnt table
1.3.6.1.4.1.20044.17.4.2.72.1.1Columnpm254dCntclientDwTimCntIndexread-onlycurrentIndex definition for the pm254dCntclientDwTimCnt table
1.3.6.1.4.1.20044.17.4.2.72.1.2Columnpm254dCntclientDwTimCntValuePortnread-onlycurrentClient Downstream Timer Counter :This is the timing counter dedicated to the downstream access counters. It is incremented every 125 us.
1.3.6.1.4.1.20044.17.4.2.72.1.3Columnpm254dCntclientDwTimCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the downstream timer counter value is invalid on Port
1.3.6.1.4.1.20044.17.4.2.72.1.4Columnpm254dCntclientDwTimCntOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a downstream timer counter overload on Port
1.3.6.1.4.1.20044.17.4.3Nodepm254dCntLine
1.3.6.1.4.1.20044.17.4.3.152Tablepm254dCntlineDfrmB1ErrCntTablenot-accessiblecurrentList of pm254dCntlineDfrmB1ErrCnt Article
1.3.6.1.4.1.20044.17.4.3.152.1Rowpm254dCntlineDfrmB1ErrCntEntrynot-accessiblecurrentRow definition for the pm254dCntlineDfrmB1ErrCnt table
1.3.6.1.4.1.20044.17.4.3.152.1.1Columnpm254dCntlineDfrmB1ErrCntIndexread-onlycurrentIndex definition for the pm254dCntlineDfrmB1ErrCnt table
1.3.6.1.4.1.20044.17.4.3.152.1.2Columnpm254dCntlineDfrmB1ErrCntValuePortnread-onlycurrentLine B1 Errors :This counter is incremented each time a B1 error is detected on the Deframer input stream. <Help> This counter gives the number of B1 errors on…
1.3.6.1.4.1.20044.17.4.3.152.1.3Columnpm254dCntlineDfrmB1ErrCntErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the B1 error counter value is invalid on Port
1.3.6.1.4.1.20044.17.4.3.152.1.4Columnpm254dCntlineDfrmB1ErrCntOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a B1 error counter overload on Port
1.3.6.1.4.1.20044.17.4.3.153Tablepm254dCntlineDfrmTimCntTablenot-accessiblecurrentList of pm254dCntlineDfrmTimCnt Article
1.3.6.1.4.1.20044.17.4.3.153.1Rowpm254dCntlineDfrmTimCntEntrynot-accessiblecurrentRow definition for the pm254dCntlineDfrmTimCnt table
1.3.6.1.4.1.20044.17.4.3.153.1.1Columnpm254dCntlineDfrmTimCntIndexread-onlycurrentIndex definition for the pm254dCntlineDfrmTimCnt table
1.3.6.1.4.1.20044.17.4.3.153.1.2Columnpm254dCntlineDfrmTimCntValuePortnread-onlycurrentLine Timer Counter :This is the timing counter dedicated to the downstream deframer counters. It is incremented every 125 us.
1.3.6.1.4.1.20044.17.4.3.153.1.3Columnpm254dCntlineDfrmTimCntErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.17.4.3.153.1.4Columnpm254dCntlineDfrmTimCntOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.17.4.259Scalarpm254dCntCountersResetread-writecurrentCounters Reset : This OID resets and restarts all the counters
1.3.6.1.4.1.20044.17.4.260Scalarpm254dCntCountersStopread-writecurrentCounters stop : This OID stops all the counters
1.3.6.1.4.1.20044.17.6Nodepm254dcontrolsWrite
1.3.6.1.4.1.20044.17.6.1Nodepm254dCtrlOther
1.3.6.1.4.1.20044.17.6.1.1Nodepm254dCtrlconfMgnt1
1.3.6.1.4.1.20044.17.6.1.1.1Scalarpm254dCtrlConf1Load1read-writecurrentLoad Configuration Tables Set N�1 :When set this OID enables loading from flash configuration1 into the PM.
1.3.6.1.4.1.20044.17.6.1.1.2Scalarpm254dCtrlConf2Load1read-writecurrentLoad Configuration Tables Set N�2 :When set this OID enables loading from flash configuration2 into the PM.
1.3.6.1.4.1.20044.17.6.1.1.10Scalarpm254dCtrlConf2Flash1read-writecurrentWrite Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura…
1.3.6.1.4.1.20044.17.6.1.1.14Scalarpm254dCtrlConf2Clear1read-writecurrentClear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o…
1.3.6.1.4.1.20044.17.6.1.4Nodepm254dCtrlsynth4
1.3.6.1.4.1.20044.17.6.1.4.1Scalarpm254dCtrlCorrelatOnread-writecurrentEnable Alarm Correlation :This OID enables the alarm correlation in the PM.
1.3.6.1.4.1.20044.17.6.1.4.2Scalarpm254dCtrlCorrelatOffread-writecurrentDisable Alarm Correlation :This OID disables the alarm correlation in the PM.
1.3.6.1.4.1.20044.17.6.1.5Nodepm254dCtrlswMgnt
1.3.6.1.4.1.20044.17.6.1.5.2Scalarpm254dCtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> …
1.3.6.1.4.1.20044.17.6.1.5.3Scalarpm254dCtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th…
1.3.6.1.4.1.20044.17.6.1.5.5Scalarpm254dCtrlLoadSwBank1read-writecurrentSet Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW…
1.3.6.1.4.1.20044.17.6.1.5.6Scalarpm254dCtrlLoadSwBank2read-writecurrentSet Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S…
1.3.6.1.4.1.20044.17.6.1.6Nodepm254dCtrlgwMgnt
1.3.6.1.4.1.20044.17.6.1.6.1Scalarpm254dCtrlCurrentGwResetread-writecurrentActive Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting.
1.3.6.1.4.1.20044.17.6.1.6.5Scalarpm254dCtrlLoadGwBank1read-writecurrentSet Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.17.6.1.6.6Scalarpm254dCtrlLoadGwBank2read-writecurrentSet Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.17.6.1.6.7Scalarpm254dCtrlLoadGwBank3read-writecurrentSet Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.17.6.1.6.8Scalarpm254dCtrlLoadGwBank4read-writecurrentSet Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.17.6.1.192Nodepm254dCtrlledTest
1.3.6.1.4.1.20044.17.6.1.192.1Scalarpm254dCtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.17.6.1.192.2Scalarpm254dCtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.17.6.1.192.3Scalarpm254dCtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.17.6.1.193Nodepm254dCtrlmoduleOosMode
1.3.6.1.4.1.20044.17.6.1.193.1Scalarpm254dCtrlModuleOosModeread-writecurrentPM Out Of Service :This OID sets the PM253 Out Of Service <Help> This control defines the service state of the complete module
1.3.6.1.4.1.20044.17.6.1.197Nodepm254dCtrlmaintenanceMode
1.3.6.1.4.1.20044.17.6.1.197.1Scalarpm254dCtrlMaintenanceModeread-writecurrentEnable Maintenance :This OID enables the maintenance mode on the PM. <Help> This control enables the maintenance mode on the PM.
1.3.6.1.4.1.20044.17.6.2Nodepm254dCtrlPort
1.3.6.1.4.1.20044.17.6.2.16Tablepm254dCtrlclientAccessLoopTablenot-accessiblecurrentList of pm254dCtrlclientAccessLoop Article
1.3.6.1.4.1.20044.17.6.2.16.1Rowpm254dCtrlclientAccessLoopEntrynot-accessiblecurrentRow definition for the pm254dCtrlclientAccessLoop table
1.3.6.1.4.1.20044.17.6.2.16.1.1Columnpm254dCtrlclientAccessLoopIndexread-onlycurrentIndex definition for the pm254dCtrlclientAccessLoop table
1.3.6.1.4.1.20044.17.6.2.16.1.2Columnpm254dCtrlclientAccessLoopPortnread-writecurrentClient Facility Loopback :This OID operates a Client Facility Loopback, looping client input signal on the client output port. The loop is located on the clien…
1.3.6.1.4.1.20044.17.6.2.18Tablepm254dCtrlclientOosModeTablenot-accessiblecurrentList of pm254dCtrlclientOosMode Article
1.3.6.1.4.1.20044.17.6.2.18.1Rowpm254dCtrlclientOosModeEntrynot-accessiblecurrentRow definition for the pm254dCtrlclientOosMode table
1.3.6.1.4.1.20044.17.6.2.18.1.1Columnpm254dCtrlclientOosModeIndexread-onlycurrentIndex definition for the pm254dCtrlclientOosMode table
1.3.6.1.4.1.20044.17.6.2.18.1.2Columnpm254dCtrlclientOosModePortnread-writecurrentClient Port Out Of Service :This OID sets the client port Out Of Service <Help> This controls defines the service state of the client port
1.3.6.1.4.1.20044.17.6.2.20Tablepm254dCtrlclientSfpOnOffCtrlTablenot-accessiblecurrentList of pm254dCtrlclientSfpOnOffCtrl Article
1.3.6.1.4.1.20044.17.6.2.20.1Rowpm254dCtrlclientSfpOnOffCtrlEntrynot-accessiblecurrentRow definition for the pm254dCtrlclientSfpOnOffCtrl table
1.3.6.1.4.1.20044.17.6.2.20.1.1Columnpm254dCtrlclientSfpOnOffCtrlIndexread-onlycurrentIndex definition for the pm254dCtrlclientSfpOnOffCtrl table
1.3.6.1.4.1.20044.17.6.2.20.1.2Columnpm254dCtrlclientSfpOnOffCtrlPortnread-writecurrentClient SFP Laser Shutdown :This OID switches off the Client SFP. <Help> This control defines the laser state of the client transceiver
1.3.6.1.4.1.20044.17.6.2.21Tablepm254dCtrlclientCsfUpInsTablenot-accessiblecurrentList of pm254dCtrlclientCsfUpIns Article
1.3.6.1.4.1.20044.17.6.2.21.1Rowpm254dCtrlclientCsfUpInsEntrynot-accessiblecurrentRow definition for the pm254dCtrlclientCsfUpIns table
1.3.6.1.4.1.20044.17.6.2.21.1.1Columnpm254dCtrlclientCsfUpInsIndexread-onlycurrentIndex definition for the pm254dCtrlclientCsfUpIns table
1.3.6.1.4.1.20044.17.6.2.21.1.2Columnpm254dCtrlclientCsfUpInsPortnread-writecurrentClient Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo…
1.3.6.1.4.1.20044.17.6.2.22Tablepm254dCtrlclientCaisDwInsTablenot-accessiblecurrentList of pm254dCtrlclientCaisDwIns Article
1.3.6.1.4.1.20044.17.6.2.22.1Rowpm254dCtrlclientCaisDwInsEntrynot-accessiblecurrentRow definition for the pm254dCtrlclientCaisDwIns table
1.3.6.1.4.1.20044.17.6.2.22.1.1Columnpm254dCtrlclientCaisDwInsIndexread-onlycurrentIndex definition for the pm254dCtrlclientCaisDwIns table
1.3.6.1.4.1.20044.17.6.2.22.1.2Columnpm254dCtrlclientCaisDwInsPortnread-writecurrentClient AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port
1.3.6.1.4.1.20044.17.6.2.26Tablepm254dCtrlclientAccessTermLoopTablenot-accessiblecurrentList of pm254dCtrlclientAccessTermLoop Article
1.3.6.1.4.1.20044.17.6.2.26.1Rowpm254dCtrlclientAccessTermLoopEntrynot-accessiblecurrentRow definition for the pm254dCtrlclientAccessTermLoop table
1.3.6.1.4.1.20044.17.6.2.26.1.1Columnpm254dCtrlclientAccessTermLoopIndexread-onlycurrentIndex definition for the pm254dCtrlclientAccessTermLoop table
1.3.6.1.4.1.20044.17.6.2.26.1.2Columnpm254dCtrlclientAccessTermLoopPortnread-writecurrentClient Terminal Loopback :This OID operates a Client Terminal Loopback, looping client input signal on the client output port. The loop is located on the line …
1.3.6.1.4.1.20044.17.6.2.48Tablepm254dCtrlProtocolTablenot-accessiblecurrentList of pm254dCtrlProtocol Article
1.3.6.1.4.1.20044.17.6.2.48.1Rowpm254dCtrlProtocolEntrynot-accessiblecurrentRow definition for the pm254dCtrlProtocol table
1.3.6.1.4.1.20044.17.6.2.48.1.1Columnpm254dCtrlProtocolIndexread-onlycurrentIndex definition for the pm254dCtrlProtocol table
1.3.6.1.4.1.20044.17.6.2.48.1.2Columnpm254dCtrlProtocolPortnread-writecurrentClient Protocol: This OID sets the protocol of the Client port.
1.3.6.1.4.1.20044.17.6.3Nodepm254dCtrlLine
1.3.6.1.4.1.20044.17.6.3.67Nodepm254dCtrllineMsAis
1.3.6.1.4.1.20044.17.6.3.67.1Scalarpm254dCtrlLineMsAisread-writecurrentInsert MS-AIS/L-AIS On Lines Output :This OID, when set, inserts an MS-AIS/L-AIS in the two outgoing STM-16/OC-48 signals.
1.3.6.1.4.1.20044.17.6.3.70Tablepm254dCtrllineUpS1Tablenot-accessiblecurrentList of pm254dCtrllineUpS1 Article
1.3.6.1.4.1.20044.17.6.3.70.1Rowpm254dCtrllineUpS1Entrynot-accessiblecurrentRow definition for the pm254dCtrllineUpS1 table
1.3.6.1.4.1.20044.17.6.3.70.1.1Columnpm254dCtrllineUpS1Indexread-onlycurrentIndex definition for the pm254dCtrllineUpS1 table
1.3.6.1.4.1.20044.17.6.3.70.1.2Columnpm254dCtrllineUpS1Portnread-writecurrentS1 Value Inserted On Lines Output :The value to be written in the S1 byte of the two upstream OC-48c/STM-16c signals is accessible through the present OID
1.3.6.1.4.1.20044.17.6.3.71Tablepm254dCtrllineUpK1Tablenot-accessiblecurrentList of pm254dCtrllineUpK1 Article
1.3.6.1.4.1.20044.17.6.3.71.1Rowpm254dCtrllineUpK1Entrynot-accessiblecurrentRow definition for the pm254dCtrllineUpK1 table
1.3.6.1.4.1.20044.17.6.3.71.1.1Columnpm254dCtrllineUpK1Indexread-onlycurrentIndex definition for the pm254dCtrllineUpK1 table
1.3.6.1.4.1.20044.17.6.3.71.1.2Columnpm254dCtrllineUpK1Portnread-writecurrentK1 Value Inserted On Lines Output :The value to be written in the K1 byte of the two upstream OC-48c/STM-16c signals is accessible through the present OID
1.3.6.1.4.1.20044.17.6.3.72Tablepm254dCtrllineUpK2Tablenot-accessiblecurrentList of pm254dCtrllineUpK2 Article
1.3.6.1.4.1.20044.17.6.3.72.1Rowpm254dCtrllineUpK2Entrynot-accessiblecurrentRow definition for the pm254dCtrllineUpK2 table
1.3.6.1.4.1.20044.17.6.3.72.1.1Columnpm254dCtrllineUpK2Indexread-onlycurrentIndex definition for the pm254dCtrllineUpK2 table
1.3.6.1.4.1.20044.17.6.3.72.1.2Columnpm254dCtrllineUpK2Portnread-writecurrentK2 Value Inserted On Lines Output :The value to be written in the K2 byte of the two upstream OC-48c/STM-16c signals is accessible through the present OID
1.3.6.1.4.1.20044.17.6.3.74Tablepm254dCtrllineOosModeTablenot-accessiblecurrentList of pm254dCtrllineOosMode Article
1.3.6.1.4.1.20044.17.6.3.74.1Rowpm254dCtrllineOosModeEntrynot-accessiblecurrentRow definition for the pm254dCtrllineOosMode table
1.3.6.1.4.1.20044.17.6.3.74.1.1Columnpm254dCtrllineOosModeIndexread-onlycurrentIndex definition for the pm254dCtrllineOosMode table
1.3.6.1.4.1.20044.17.6.3.74.1.2Columnpm254dCtrllineOosModePortnread-writecurrentLine Port Out Of Service :This OID sets the line port Out Of Service <Help> This control defines the service state of the line port
1.3.6.1.4.1.20044.17.6.3.93Nodepm254dCtrlDccMgnt
1.3.6.1.4.1.20044.17.6.3.93.1Scalarpm254dCtrlLineNumberread-writecurrentSwitch to Line Port : This OID sets the active line number
1.3.6.1.4.1.20044.17.6.3.93.2Scalarpm254dCtrlDccModeread-writecurrentDCC Switch Mode (Auto Or Manual) :This OID selects the manual (1) or automatic (0) switch method <Help> This control defines the DCC Switch mode to Automatic o…
1.3.6.1.4.1.20044.17.6.3.160Tablepm254dCtrllineAccessLoopTablenot-accessiblecurrentList of pm254dCtrllineAccessLoop Article
1.3.6.1.4.1.20044.17.6.3.160.1Rowpm254dCtrllineAccessLoopEntrynot-accessiblecurrentRow definition for the pm254dCtrllineAccessLoop table
1.3.6.1.4.1.20044.17.6.3.160.1.1Columnpm254dCtrllineAccessLoopIndexread-onlycurrentIndex definition for the pm254dCtrllineAccessLoop table
1.3.6.1.4.1.20044.17.6.3.160.1.2Columnpm254dCtrllineAccessLoopPortnread-writecurrentLine Facility Loopback :This OID operates a Line Facility Loopback, looping line input signal on the line output port. The loop is located on the line transcei…
1.3.6.1.4.1.20044.17.6.3.161Tablepm254dCtrllineLoopTransceiverTablenot-accessiblecurrentList of pm254dCtrllineLoopTransceiver Article
1.3.6.1.4.1.20044.17.6.3.161.1Rowpm254dCtrllineLoopTransceiverEntrynot-accessiblecurrentRow definition for the pm254dCtrllineLoopTransceiver table
1.3.6.1.4.1.20044.17.6.3.161.1.1Columnpm254dCtrllineLoopTransceiverIndexread-onlycurrentIndex definition for the pm254dCtrllineLoopTransceiver table
1.3.6.1.4.1.20044.17.6.3.161.1.2Columnpm254dCtrllineLoopTransceiverPortnread-writecurrentLine Terminal Loopback :This OID operates a Line Terminal Loopback, looping line input signal on the line output port. The loop is located on all client transc…
1.3.6.1.4.1.20044.17.6.3.162Tablepm254dCtrllineSfpOnOffCtrlTablenot-accessiblecurrentList of pm254dCtrllineSfpOnOffCtrl Article
1.3.6.1.4.1.20044.17.6.3.162.1Rowpm254dCtrllineSfpOnOffCtrlEntrynot-accessiblecurrentRow definition for the pm254dCtrllineSfpOnOffCtrl table
1.3.6.1.4.1.20044.17.6.3.162.1.1Columnpm254dCtrllineSfpOnOffCtrlIndexread-onlycurrentIndex definition for the pm254dCtrllineSfpOnOffCtrl table
1.3.6.1.4.1.20044.17.6.3.162.1.2Columnpm254dCtrllineSfpOnOffCtrlPortnread-writecurrentLine SFP Laser Shutdown :This OID switches off the Line SFP. <Help> This control defines the laser state of the line transceiver
1.3.6.1.4.1.20044.17.6.3.198Tablepm254dCtrldccEnableTablenot-accessiblecurrentList of pm254dCtrldccEnable Article
1.3.6.1.4.1.20044.17.6.3.198.1Rowpm254dCtrldccEnableEntrynot-accessiblecurrentRow definition for the pm254dCtrldccEnable table
1.3.6.1.4.1.20044.17.6.3.198.1.1Columnpm254dCtrldccEnableIndexread-onlycurrentIndex definition for the pm254dCtrldccEnable table
1.3.6.1.4.1.20044.17.6.3.198.1.2Columnpm254dCtrldccEnablePortnread-writecurrentDCC Mode : This OID enables the DCC mode on the PM <Help> This control enables the DCC mode on the PM
1.3.6.1.4.1.20044.17.7Nodepm254dri
1.3.6.1.4.1.20044.17.7.1Nodepm254driTable
1.3.6.1.4.1.20044.17.7.1.1Tablepm254dRinvClientTablenot-accessiblecurrentList of the SFPs on the selected module
1.3.6.1.4.1.20044.17.7.1.1.1Rowpm254dRinvClientEntrynot-accessiblecurrentRow definition for the Client SFP table
1.3.6.1.4.1.20044.17.7.1.1.1.1Columnpm254dRinvClientIndexread-onlycurrentIndex for Client SFP table
1.3.6.1.4.1.20044.17.7.1.1.1.2Columnpm254dRinvSfpClientread-onlycurrentInventory for the SFP: This OID contains the inventory for the Client SFP
1.3.6.1.4.1.20044.17.7.1.2Tablepm254dRinvLineTablenot-accessiblecurrentList of the SFPs on the selected module
1.3.6.1.4.1.20044.17.7.1.2.1Rowpm254dRinvLineEntrynot-accessiblecurrentRow definition for the SFP table
1.3.6.1.4.1.20044.17.7.1.2.1.1Columnpm254dRinvLineIndexread-onlycurrentIndex for SFP table
1.3.6.1.4.1.20044.17.7.1.2.1.2Columnpm254dRinvsfpLineread-onlycurrentInventory for the SFP: This OID contains the inventory for the Line SFP
1.3.6.1.4.1.20044.17.7.2Scalarpm254dRinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.17.7.3Scalarpm254dRinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.17.7.4Scalarpm254dRinvModulePlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.17.7.5Scalarpm254dRinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.17.7.6Scalarpm254dRinvGwPlatformread-onlycurrentGW platform desciption: This OID contains the description of the Gateware platform.
1.3.6.1.4.1.20044.17.8Nodepm254ddownload
1.3.6.1.4.1.20044.17.8.1Nodepm254dDwlOther
1.3.6.1.4.1.20044.17.8.1.0Nodepm254dDwlrestartProcess
1.3.6.1.4.1.20044.17.8.1.0.1Scalarpm254dDwlWarmRestartProcessedread-onlycurrentWarm Restart :This OID indicates that the PM last restart was a Warm RESTART
1.3.6.1.4.1.20044.17.8.1.0.2Scalarpm254dDwlColdRestartProcessedread-onlycurrentCold Restart :This OID indicates that the PM last restart was a Cold RESTART
1.3.6.1.4.1.20044.17.8.1.1Nodepm254dDwlswBanksUsed
1.3.6.1.4.1.20044.17.8.1.1.1Scalarpm254dDwlSwBank1Usedread-onlycurrentSW bank 1 active :This OID indicates the PM is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby
1.3.6.1.4.1.20044.17.8.1.1.2Scalarpm254dDwlSwBank2Usedread-onlycurrentSW bank 2 active :This OID indicates the PM is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby
1.3.6.1.4.1.20044.17.8.1.1.5Scalarpm254dDwlSwBank1Notemptyread-onlycurrentSW bank 1 loaded :This OID indicates a software is loaded in SW bank1 <Help> This status indicates if the SW bank 1 contains SW package
1.3.6.1.4.1.20044.17.8.1.1.6Scalarpm254dDwlSwBank2Notemptyread-onlycurrentSW bank 2 loaded :This OID indicates a software is loaded in SW bank2 <Help> This status indicates if the SW bank 2 contains SW package
1.3.6.1.4.1.20044.17.8.1.2Nodepm254dDwlgwBanksUsed
1.3.6.1.4.1.20044.17.8.1.2.1Scalarpm254dDwlGwBank1Usedread-onlycurrentGW bank 1 active :This OID indicates the PM is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby
1.3.6.1.4.1.20044.17.8.1.2.2Scalarpm254dDwlGwBank2Usedread-onlycurrentGW bank 2 active :This OID indicates the PM is working on GW bank 2
1.3.6.1.4.1.20044.17.8.1.2.3Scalarpm254dDwlGwBank3Usedread-onlycurrentGW bank 3 active :This OID indicates the PM is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby
1.3.6.1.4.1.20044.17.8.1.2.4Scalarpm254dDwlGwBank4Usedread-onlycurrentGW bank 4 active :This OID indicates the PM is working on GW bank 4
1.3.6.1.4.1.20044.17.8.1.2.5Scalarpm254dDwlGwBank1Notemptyread-onlycurrentGW bank 1 loaded :This OID indicates a gateware is loaded in GW bank1 <Help> This status indicates if the GW bank 1 contains GW package
1.3.6.1.4.1.20044.17.8.1.2.6Scalarpm254dDwlGwBank2Notemptyread-onlycurrentGW bank 2 loaded :This OID indicates a gateware is loaded in GW bank2
1.3.6.1.4.1.20044.17.8.1.2.7Scalarpm254dDwlGwBank3Notemptyread-onlycurrentGW bank 3 loaded :This OID indicates a gateware is loaded in GW bank3 <Help> This status indicates if the GW bank 3 contains GW package
1.3.6.1.4.1.20044.17.8.1.2.8Scalarpm254dDwlGwBank4Notemptyread-onlycurrentGW bank 4 loaded :This OID indicates a gateware is loaded in GW bank4
1.3.6.1.4.1.20044.17.8.2Nodepm254dDwlPort
1.3.6.1.4.1.20044.17.8.3Nodepm254dDwlLine
1.3.6.1.4.1.20044.17.9Nodepm254dConfig
1.3.6.1.4.1.20044.17.9.1Nodepm254dCfgAccessCAisCsf
1.3.6.1.4.1.20044.17.9.1.1Tablepm254dCfgClientcaiscsfTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.17.9.1.1.1Rowpm254dCfgClientcaiscsfEntrynot-accessiblecurrentRow definition for the accessCAisCsf table
1.3.6.1.4.1.20044.17.9.1.1.1.1Columnpm254dCfgClientcaiscsfIndexread-onlycurrentIndex definition for the clientcaiscsf table
1.3.6.1.4.1.20044.17.9.1.1.1.3Columnpm254dCfgCAisModePortnread-writecurrentCAIS mode on Client Port :This register enables/disables Client Port laser shutdown on CAIS insertion condition
1.3.6.1.4.1.20044.17.9.1.1.1.4Columnpm254dCfgSts24cContribPortnread-writecurrentSts24c contributors on Client Port :This register selects the contributors of STS24c to downstream CAIS/CSF on Port
1.3.6.1.4.1.20044.17.9.1.1.1.9Columnpm254dCfgUpAccessioAlmPortnread-writecurrentCSF contributors on Client Port :This register configures the contributors to upstream CSF insertion on the Client Port.
1.3.6.1.4.1.20044.17.9.1.1.1.10Columnpm254dCfgUpMapperDeAlmPortnread-writecurrentCSF contributors on Client Port :This register configures the contributors to upstream CSF insertion on the Client Port.
1.3.6.1.4.1.20044.17.9.1.1.1.18Columnpm254dCfgDownMapperDeAlmPortnread-writecurrentCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on Client Port.
1.3.6.1.4.1.20044.17.9.1.1.1.19Columnpm254dCfgDownDfrmAlmPortnread-writecurrentCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on Client Port.
1.3.6.1.4.1.20044.17.9.1.1.1.22Columnpm254dCfgDownLineIoAlmPortnread-writedeprecatedCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on Client Port.
1.3.6.1.4.1.20044.17.9.2Nodepm254dCfgStartup
1.3.6.1.4.1.20044.17.9.2.1Tablepm254dCfgClientStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.17.9.2.1.1Rowpm254dCfgClientStartupEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.17.9.2.1.1.1Columnpm254dCfgClientStartupIndexread-onlycurrentIndex definition for the clientStartup table
1.3.6.1.4.1.20044.17.9.2.1.1.3Columnpm254dCfgSystConfPortPortnread-writecurrentDefault Settings on Client Port :This register configures the default initialisation settings on the client port.
1.3.6.1.4.1.20044.17.9.2.1.1.4Columnpm254dCfgNetConfPortPortnread-writecurrentDefault Protocol on Client Port :This register configures the default initialisation protocol on the client port.
1.3.6.1.4.1.20044.17.9.2.1.1.6Columnpm254dCfgPortsOptionsPortnread-writedeprecatedDefault Options on Client Port :This register configures the default options on the client port
1.3.6.1.4.1.20044.17.9.2.2Nodepm254dtablelineStartup
1.3.6.1.4.1.20044.17.9.2.2.2Scalarpm254dCfgsystConfLine1read-writecurrentDefault Settings on Line 1 :This register configures the default initialisation settings on Line port 1.
1.3.6.1.4.1.20044.17.9.2.2.5Scalarpm254dCfglineOptions1read-writecurrentDefault Options on Active Line Port 1 :This register configures the default options on the active line port
1.3.6.1.4.1.20044.17.9.2.2.6Scalarpm254dCfgsystConfLine2read-writecurrentDefault Settings on Line 2 :This register configures the default initialisation settings on Line port 2.
1.3.6.1.4.1.20044.17.9.2.2.7Scalarpm254dCfglineSelectionread-writecurrentDefault Settings of active line :This register configures the start up active line.
1.3.6.1.4.1.20044.17.9.2.2.9Scalarpm254dCfglineOptions2read-writecurrentDefault Options on Active Line Port 2 :This register configures the default options on the active line port
1.3.6.1.4.1.20044.17.9.3Nodepm254dCfgLabels
1.3.6.1.4.1.20044.17.9.3.1Tablepm254dCfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.17.9.3.1.1Rowpm254dCfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.17.9.3.1.1.1Columnpm254dCfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.17.9.3.1.1.3Columnpm254dCfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.17.9.3.2Tablepm254dCfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.17.9.3.2.1Rowpm254dCfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.17.9.3.2.1.1Columnpm254dCfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.17.9.3.2.1.3Columnpm254dCfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.17.9.257Scalarpm254dCfgWriteConfigurationread-writecurrentWrite configuration to PM: This OID, when sets, write the complete configuration to the PM.
1.3.6.1.4.1.20044.17.10Nodepm254dtraps
1.3.6.1.4.1.20044.17.10.2Scalarpm254dTrapPortNumberread-onlycurrentLast port which generated a trap
1.3.6.1.4.1.20044.17.10.3Scalarpm254dTrapBoardNumberread-onlycurrentLast module which generated a trap
1.3.6.1.4.1.20044.17.10.4Scalarpm254dTrapLineNumberread-onlycurrentLast line which generated a trap
1.3.6.1.4.1.20044.17.10.30Notificationpm254dLineTrapNotUrgentGoesOncurrentNot urgent line default is activated
1.3.6.1.4.1.20044.17.10.31Notificationpm254dLineTrapNotUrgentGoesOffcurrentNot urgent line default disappeared
1.3.6.1.4.1.20044.17.10.32Notificationpm254dLineTrapUrgentGoesOncurrentUrgent line default is activated
1.3.6.1.4.1.20044.17.10.33Notificationpm254dLineTrapUrgentGoesOffcurrentUrgent line default disappeared
1.3.6.1.4.1.20044.17.10.34Notificationpm254dLineTrapCritGoesOncurrentCritical line default is activated
1.3.6.1.4.1.20044.17.10.35Notificationpm254dLineTrapCritGoesOffcurrentCritical line default disappeared
1.3.6.1.4.1.20044.17.10.40Notificationpm254dClientTrapNotUrgentGoesOncurrentNot urgent client default is activated
1.3.6.1.4.1.20044.17.10.41Notificationpm254dClientTrapNotUrgentGoesOffcurrentNot urgent client default disappeared
1.3.6.1.4.1.20044.17.10.42Notificationpm254dClientTrapUrgentGoesOncurrentUrgent client default is activated
1.3.6.1.4.1.20044.17.10.43Notificationpm254dClientTrapUrgentGoesOffcurrentUrgent client default disappeared
1.3.6.1.4.1.20044.17.10.44Notificationpm254dClientTrapCritGoesOncurrentCritical client default is activated
1.3.6.1.4.1.20044.17.10.45Notificationpm254dClientTrapCritGoesOffcurrentCritical client default disappeared
1.3.6.1.4.1.20044.17.11Nodepm254dMonitoring
1.3.6.1.4.1.20044.17.11.1Nodepm254dMonOther
1.3.6.1.4.1.20044.17.11.1.3Nodepm254dMonRmon
1.3.6.1.4.1.20044.17.11.1.3.359Scalarpm254dMonCountersResetread-writecurrentRMON Counters Reset:This OID resets and restarts all the RMON counters
1.3.6.1.4.1.20044.17.11.1.3.360Scalarpm254dMonCountersStopread-writecurrentRMON Counters stop:This OID stops all the RMON counters
1.3.6.1.4.1.20044.17.11.2Nodepm254dMonClient
1.3.6.1.4.1.20044.17.11.2.4Nodepm254dMonClientRmonCounter
1.3.6.1.4.1.20044.17.11.2.4.16Tablepm254dMonupRmonByteCntTablenot-accessiblecurrentList of pm254dMonupRmonByteCnt Article
1.3.6.1.4.1.20044.17.11.2.4.16.1Rowpm254dMonupRmonByteCntEntrynot-accessiblecurrentRow definition for the pm254dMonupRmonByteCnt table
1.3.6.1.4.1.20044.17.11.2.4.16.1.1Columnpm254dMonupRmonByteCntIndexread-onlycurrentIndex definition for the pm254dMonupRmonByteCnt table
1.3.6.1.4.1.20044.17.11.2.4.16.1.2Columnpm254dMonupRmonByteCntValuePortnread-onlycurrentClient Input Bytes :This counter is increased each time a data byte is received on the client port <Help> This counter gives the number of bytes received on th…
1.3.6.1.4.1.20044.17.11.2.4.16.1.3Columnpm254dMonupRmonByteCntErrorPortnread-onlycurrentBytes Counter Error :This OID when set indicates the Bytes counter value is invalid on clinet port
1.3.6.1.4.1.20044.17.11.2.4.16.1.4Columnpm254dMonupRmonByteCntOverloadPortnread-onlycurrentBytes Counter Overload :This OID when set indicates a Bytes counter overload on client port
1.3.6.1.4.1.20044.17.11.2.4.24Tablepm254dMonupRmonCrcErrorCntTablenot-accessiblecurrentList of pm254dMonupRmonCrcErrorCnt Article
1.3.6.1.4.1.20044.17.11.2.4.24.1Rowpm254dMonupRmonCrcErrorCntEntrynot-accessiblecurrentRow definition for the pm254dMonupRmonCrcErrorCnt table
1.3.6.1.4.1.20044.17.11.2.4.24.1.1Columnpm254dMonupRmonCrcErrorCntIndexread-onlycurrentIndex definition for the pm254dMonupRmonCrcErrorCnt table
1.3.6.1.4.1.20044.17.11.2.4.24.1.2Columnpm254dMonupRmonCrcErrorCntValuePortnread-onlycurrentClient Input CRC Errors :This counter is increased each time a CRC error is detected on the client port <Help> This counter gives the number of CRC Errors rece…
1.3.6.1.4.1.20044.17.11.2.4.24.1.3Columnpm254dMonupRmonCrcErrorCntErrorPortnread-onlycurrentCRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on clinet port
1.3.6.1.4.1.20044.17.11.2.4.24.1.4Columnpm254dMonupRmonCrcErrorCntOverloadPortnread-onlycurrentCRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on client port
1.3.6.1.4.1.20044.17.11.2.4.32Tablepm254dMonupRmonPacketsCntTablenot-accessiblecurrentList of pm254dMonupRmonPacketsCnt Article
1.3.6.1.4.1.20044.17.11.2.4.32.1Rowpm254dMonupRmonPacketsCntEntrynot-accessiblecurrentRow definition for the pm254dMonupRmonPacketsCnt table
1.3.6.1.4.1.20044.17.11.2.4.32.1.1Columnpm254dMonupRmonPacketsCntIndexread-onlycurrentIndex definition for the pm254dMonupRmonPacketsCnt table
1.3.6.1.4.1.20044.17.11.2.4.32.1.2Columnpm254dMonupRmonPacketsCntValuePortnread-onlycurrentClient Input Packets :This counter is increased each time a packet is received on the client port <Help> This counter gives the number of packets received on t…
1.3.6.1.4.1.20044.17.11.2.4.32.1.3Columnpm254dMonupRmonPacketsCntErrorPortnread-onlycurrentPackets Counter Error :This OID when set indicates the Packets counter value is invalid on clinet port
1.3.6.1.4.1.20044.17.11.2.4.32.1.4Columnpm254dMonupRmonPacketsCntOverloadPortnread-onlycurrentPackets Counter Overload :This OID when set indicates a Packets counter overload on client port
1.3.6.1.4.1.20044.17.11.2.4.40Tablepm254dMonupRmonBroadcastCntTablenot-accessiblecurrentList of pm254dMonupRmonBroadcastCnt Article
1.3.6.1.4.1.20044.17.11.2.4.40.1Rowpm254dMonupRmonBroadcastCntEntrynot-accessiblecurrentRow definition for the pm254dMonupRmonBroadcastCnt table
1.3.6.1.4.1.20044.17.11.2.4.40.1.1Columnpm254dMonupRmonBroadcastCntIndexread-onlycurrentIndex definition for the pm254dMonupRmonBroadcastCnt table
1.3.6.1.4.1.20044.17.11.2.4.40.1.2Columnpm254dMonupRmonBroadcastCntValuePortnread-onlycurrentClient Input Broadcast Packets :This counter is increased each time a broadcast packet is received on the client port <Help> This counter gives the number of B…
1.3.6.1.4.1.20044.17.11.2.4.40.1.3Columnpm254dMonupRmonBroadcastCntErrorPortnread-onlycurrentBroadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on clinet port
1.3.6.1.4.1.20044.17.11.2.4.40.1.4Columnpm254dMonupRmonBroadcastCntOverloadPortnread-onlycurrentBroadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port
1.3.6.1.4.1.20044.17.11.2.4.48Tablepm254dMonupRmonMulticastCntTablenot-accessiblecurrentList of pm254dMonupRmonMulticastCnt Article
1.3.6.1.4.1.20044.17.11.2.4.48.1Rowpm254dMonupRmonMulticastCntEntrynot-accessiblecurrentRow definition for the pm254dMonupRmonMulticastCnt table
1.3.6.1.4.1.20044.17.11.2.4.48.1.1Columnpm254dMonupRmonMulticastCntIndexread-onlycurrentIndex definition for the pm254dMonupRmonMulticastCnt table
1.3.6.1.4.1.20044.17.11.2.4.48.1.2Columnpm254dMonupRmonMulticastCntValuePortnread-onlycurrentClient Input Multicast Packets :This counter is increased each time a Multicast packet is received on the client port <Help> This counter gives the number of M…
1.3.6.1.4.1.20044.17.11.2.4.48.1.3Columnpm254dMonupRmonMulticastCntErrorPortnread-onlycurrentMulticast Counter Error :This OID when set indicates the Multicast counter value is invalid on clinet port
1.3.6.1.4.1.20044.17.11.2.4.48.1.4Columnpm254dMonupRmonMulticastCntOverloadPortnread-onlycurrentMulticast Counter Overload :This OID when set indicates a Multicast counter overload on client port