EKINOPS-Pm404-MIB

280 objects
MIB for the Ekinops Pm404 hardware.
OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.25IdentitymodulePm404MIB for the Ekinops Pm404 hardware.
1.3.6.1.4.1.20044.25.2Nodepm404alarms
1.3.6.1.4.1.20044.25.2.1Nodepm404AlmOther
1.3.6.1.4.1.20044.25.2.1.1Nodepm404AlmOtherNurg
1.3.6.1.4.1.20044.25.2.1.1.2Nodepm404AlmsynthAlm2
1.3.6.1.4.1.20044.25.2.1.1.2.1Scalarpm404AlmConfTableSaveread-onlycurrentPM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> other…
1.3.6.1.4.1.20044.25.2.1.1.2.2Scalarpm404AlmInvUploadread-onlycurrentInventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> other (1) <Alarmtype> other (1) <Polarit…
1.3.6.1.4.1.20044.25.2.1.1.2.3Scalarpm404AlmConfTableLoadread-onlycurrentPM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> other (1) <Alarmt…
1.3.6.1.4.1.20044.25.2.1.1.2.4Scalarpm404AlmCorrelatOffread-onlycurrentNot Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> other (1) <Alarmtype> other (1) <Pol…
1.3.6.1.4.1.20044.25.2.1.2Nodepm404AlmOtherUrg
1.3.6.1.4.1.20044.25.2.1.3Nodepm404AlmOtherCrit
1.3.6.1.4.1.20044.25.2.1.3.0Nodepm404AlmsynthAlm0
1.3.6.1.4.1.20044.25.2.1.3.0.9Scalarpm404AlmModuleGlobFailureread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the PM <Condtype> MODULE_GLOB_FAILURE <Probcause> equipmentMalfunction (16) <Alarmty…
1.3.6.1.4.1.20044.25.2.1.3.0.15Scalarpm404AlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.25.2.1.3.0.16Scalarpm404AlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.25.2.2Nodepm404AlmClient
1.3.6.1.4.1.20044.25.2.2.1Nodepm404AlmClientNurg
1.3.6.1.4.1.20044.25.2.2.1.32Tablepm404Almline1SfpWarnDdmTablenot-accessiblecurrentList of pm404Almline1SfpWarnDdm Article
1.3.6.1.4.1.20044.25.2.2.1.32.1Rowpm404Almline1SfpWarnDdmEntrynot-accessiblecurrentRow definition for the pm404Almline1SfpWarnDdm table
1.3.6.1.4.1.20044.25.2.2.1.32.1.1Columnpm404Almline1SfpWarnDdmIndexread-onlycurrentIndex definition for the pm404Almline1SfpWarnDdm table
1.3.6.1.4.1.20044.25.2.2.1.32.1.2Columnpm404AlmLine1TxPwLowWngPortnread-onlycurrentLine 1 SFP Tx Power Low Warning :Warning indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> LI…
1.3.6.1.4.1.20044.25.2.2.1.32.1.3Columnpm404AlmLine1TxPwrHighWngPortnread-onlycurrentLine 1 SFP Tx Power High Warning :Warning indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.25.2.2.1.32.1.4Columnpm404AlmLine1TxBiasLowWngPortnread-onlycurrentLine 1 SFP Bias Low Warning :Warning indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.25.2.2.1.32.1.5Columnpm404AlmLine1TxBiasHighWngPortnread-onlycurrentLine 1 SFP Bias High Warning :Warning indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.25.2.2.1.32.1.6Columnpm404AlmLine1VccLowWngPortnread-onlycurrentLine 1 SFP Power Supply Low Warning :Warning indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.25.2.2.1.32.1.7Columnpm404AlmLine1VccHighWngPortnread-onlycurrentLine 1 SFP Power Supply High Warning :Warning indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condty…
1.3.6.1.4.1.20044.25.2.2.1.32.1.8Columnpm404AlmLine1TempLowWngPortnread-onlycurrentLine 1 SFP Temp Low Warning :Warning indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE1_T…
1.3.6.1.4.1.20044.25.2.2.1.32.1.9Columnpm404AlmLine1TempHighWngPortnread-onlycurrentLine 1 SFP Temp High Warning :Warning indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE1…
1.3.6.1.4.1.20044.25.2.2.1.32.1.16Columnpm404AlmLine1RxPwrLowWngPortnread-onlycurrentLine 1 SFP Rx Power Low Warning :Warning indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> LIN…
1.3.6.1.4.1.20044.25.2.2.1.32.1.17Columnpm404AlmLine1RxPwrHighWngPortnread-onlycurrentLine 1 SFP Rx Power High Warning :Warning indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> L…
1.3.6.1.4.1.20044.25.2.2.2Nodepm404AlmClientUrg
1.3.6.1.4.1.20044.25.2.2.2.24Tablepm404Almline1SfpAlmDdmTablenot-accessiblecurrentList of pm404Almline1SfpAlmDdm Article
1.3.6.1.4.1.20044.25.2.2.2.24.1Rowpm404Almline1SfpAlmDdmEntrynot-accessiblecurrentRow definition for the pm404Almline1SfpAlmDdm table
1.3.6.1.4.1.20044.25.2.2.2.24.1.1Columnpm404Almline1SfpAlmDdmIndexread-onlycurrentIndex definition for the pm404Almline1SfpAlmDdm table
1.3.6.1.4.1.20044.25.2.2.2.24.1.2Columnpm404AlmLine1TxPwrLowAlaPortnread-onlycurrentLine 1 SFP Tx Power Low :Alarm indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE1_TX_PWR…
1.3.6.1.4.1.20044.25.2.2.2.24.1.3Columnpm404AlmLine1Line1TxPwrHighAlaPortnread-onlycurrentLine 1 SFP Tx Power High :Alarm indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE1_LINE…
1.3.6.1.4.1.20044.25.2.2.2.24.1.4Columnpm404AlmLine1TxBiasLowAlaPortnread-onlycurrentLine 1 SFP Bias Low :Alarm indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE1_TX_B…
1.3.6.1.4.1.20044.25.2.2.2.24.1.5Columnpm404AlmLine1TxBiasHighAlaPortnread-onlycurrentLine 1 SFP Bias High :Alarm indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE1_TX…
1.3.6.1.4.1.20044.25.2.2.2.24.1.6Columnpm404AlmLine1VccLowAlaPortnread-onlycurrentLine 1 SFP Power Supply Low :Alarm indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE1_VC…
1.3.6.1.4.1.20044.25.2.2.2.24.1.7Columnpm404AlmLine1VccHighAlaPortnread-onlycurrentLine 1 SFP Power Supply High :Alarm indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE1_…
1.3.6.1.4.1.20044.25.2.2.2.24.1.8Columnpm404AlmLine1TempLowAlaPortnread-onlycurrentLine 1 SFP Temp Low :Alarm indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE1_TEMP_LOW_AL…
1.3.6.1.4.1.20044.25.2.2.2.24.1.9Columnpm404AlmLine1TempHighAlaPortnread-onlycurrentLine 1 SFP Temp High :Alarm indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE1_TEMP_HIGH…
1.3.6.1.4.1.20044.25.2.2.2.24.1.16Columnpm404AlmLine1RxPwrLowAlaPortnread-onlycurrentLine 1 SFP Rx Power Low :Alarm indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE1_RX_PWR_…
1.3.6.1.4.1.20044.25.2.2.2.24.1.17Columnpm404AlmLine1RxPwrHighAlaPortnread-onlycurrentLine 1 SFP Rx Power High :Alarm indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE1_RX_PW…
1.3.6.1.4.1.20044.25.2.2.3Nodepm404AlmClientCrit
1.3.6.1.4.1.20044.25.2.2.3.8Tablepm404AlmsynthAlmLine1Tablenot-accessiblecurrentList of pm404AlmsynthAlmLine1 Article
1.3.6.1.4.1.20044.25.2.2.3.8.1Rowpm404AlmsynthAlmLine1Entrynot-accessiblecurrentRow definition for the pm404AlmsynthAlmLine1 table
1.3.6.1.4.1.20044.25.2.2.3.8.1.1Columnpm404AlmsynthAlmLine1Indexread-onlycurrentIndex definition for the pm404AlmsynthAlmLine1 table
1.3.6.1.4.1.20044.25.2.2.3.8.1.2Columnpm404AlmLine1SfpAbsentPortnread-onlycurrentLine 1 SFP Absent :This OID indicates that the SFP module is not present in the Line 1 port. <Help> This alarm indicates if the line 1 transceiver is present. …
1.3.6.1.4.1.20044.25.2.2.3.8.1.3Columnpm404AlmLine1DdmAbsentPortnread-onlycurrentDDM Supported On Line 1 SFP :This OID indicates that the Line 1 SFP module does not support the Digital Diagnostic Monitoring function <Help> This status indic…
1.3.6.1.4.1.20044.25.2.2.3.8.1.5Columnpm404AlmLine1HwFailAccPortnread-onlycurrentLine 1 HW Fail :This OID indicates a failure on Line 1 port, most probably caused by a HW issue. <Condtype> LINE1_HW_FAIL_ACC_A <Probcause> equipmentMalfunctio…
1.3.6.1.4.1.20044.25.2.2.3.8.1.6Columnpm404AlmLine1LsdPortnread-onlycurrentLine 1 SFP Laser Shutdown :This OID indicates the Line 1 SFP transmitter output has shut down. <Help> This status indicates if the line 1 transceiver laser is …
1.3.6.1.4.1.20044.25.2.2.3.8.1.7Columnpm404AlmLine1LocalOosPortnread-onlycurrentLine 1 Port In Service :This OID indicates that the local Line 1 port is In Service (1) or Out of Service (2) <Help> This status indicates if the line port 1 i…
1.3.6.1.4.1.20044.25.2.2.3.8.1.9Columnpm404AlmLine1DwCaisPortnread-onlycurrentLine 1 AIS Inserted :This OID indicates a CAIS has been inserted on the output Line 1 port. <Help> This status indicates if a Line Alarm Indication Signal is c…
1.3.6.1.4.1.20044.25.2.2.3.8.1.10Columnpm404AlmLine1SfpDdmWarningPortnread-onlycurrentWarning On Line 1 SFP DDM :This OID indicates a warning is being received from the Line 1 SFP DDM <Help> This alarm indicates if a DDM Warning has been detecte…
1.3.6.1.4.1.20044.25.2.2.3.8.1.11Columnpm404AlmLine1SfpDdmAlmPortnread-onlycurrentAlarm On Line 1 SFP DDM :This OID indicates an alarm is being received from the Line 1 SFP DDM <Help> This alarm indicates if a DDM Alarm has been detected on …
1.3.6.1.4.1.20044.25.2.2.3.8.1.13Columnpm404AlmLine1FailAccPortnread-onlycurrentLine 1 Access Fail :This OID indicates a failure on the Line 1 port <Condtype> LINE1_FAIL_ACC_A <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlar…
1.3.6.1.4.1.20044.25.2.2.3.16Tablepm404Almline1AccessioAlmTablenot-accessiblecurrentList of pm404Almline1AccessioAlm Article
1.3.6.1.4.1.20044.25.2.2.3.16.1Rowpm404Almline1AccessioAlmEntrynot-accessiblecurrentRow definition for the pm404Almline1AccessioAlm table
1.3.6.1.4.1.20044.25.2.2.3.16.1.1Columnpm404Almline1AccessioAlmIndexread-onlycurrentIndex definition for the pm404Almline1AccessioAlm table
1.3.6.1.4.1.20044.25.2.2.3.16.1.2Columnpm404AlmLine1LasFailPortnread-onlycurrentLine 1 SFP Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the Line 1 port (this alarm reports the transmitter failure alarm …
1.3.6.1.4.1.20044.25.2.2.3.16.1.5Columnpm404AlmLine1LosPortnread-onlycurrentLoss Of Optical Signal On Line 1 :This OID indicates that no signal is present on the SFP of the Line 1 port <Help> This alarm indicates if an optical signal i…
1.3.6.1.4.1.20044.25.2.2.3.16.1.7Columnpm404AlmLine1LosCdrPortnread-onlycurrentLoss Of Signal On CDR On Line 1 : <Condtype> LINE1_LOS_CDR_A <Probcause> receiveFailure (41) <Alarmtype> equipmentAlarm (5) <Polarity> (2)
1.3.6.1.4.1.20044.25.2.2.3.16.1.8Columnpm404AlmLine1ErrSigCdrPortnread-onlycurrentError Signal On CDR On Line 1 : <Condtype> LINE1__ERR_SIG_CDR_A <Probcause> receiveFailure (41) <Alarmtype> equipmentAlarm (5) <Polarity> (2)
1.3.6.1.4.1.20044.25.2.3Nodepm404AlmLine
1.3.6.1.4.1.20044.25.2.3.1Nodepm404AlmLineNurg
1.3.6.1.4.1.20044.25.2.3.1.36Tablepm404Almline2SfpWarnDdmTablenot-accessiblecurrentList of pm404Almline2SfpWarnDdm Article
1.3.6.1.4.1.20044.25.2.3.1.36.1Rowpm404Almline2SfpWarnDdmEntrynot-accessiblecurrentRow definition for the pm404Almline2SfpWarnDdm table
1.3.6.1.4.1.20044.25.2.3.1.36.1.1Columnpm404Almline2SfpWarnDdmIndexread-onlycurrentIndex definition for the pm404Almline2SfpWarnDdm table
1.3.6.1.4.1.20044.25.2.3.1.36.1.2Columnpm404AlmLine2TxPwLowWngPortnread-onlycurrentLine 2 SFP Tx Power Low Warning :Warning indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> LI…
1.3.6.1.4.1.20044.25.2.3.1.36.1.3Columnpm404AlmLine2TxPwrHighWngPortnread-onlycurrentLine 2 SFP Tx Power High Warning :Warning indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.25.2.3.1.36.1.4Columnpm404AlmLine2TxBiasLowWngPortnread-onlycurrentLine 2 SFP Bias Low Warning :Warning indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.25.2.3.1.36.1.5Columnpm404AlmLine2TxBiasHighWngPortnread-onlycurrentLine 2 SFP Bias High Warning :Warning indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.25.2.3.1.36.1.6Columnpm404AlmLine2VccLowWngPortnread-onlycurrentLine 2 SFP Power Supply Low Warning :Warning indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.25.2.3.1.36.1.7Columnpm404AlmLine2VccHighWngPortnread-onlycurrentLine 2 SFP Power Supply High Warning :Warning indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condty…
1.3.6.1.4.1.20044.25.2.3.1.36.1.8Columnpm404AlmLine2TempLowWngPortnread-onlycurrentLine 2 SFP Temp Low Warning :Warning indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE2_T…
1.3.6.1.4.1.20044.25.2.3.1.36.1.9Columnpm404AlmLine2TempHighWngPortnread-onlycurrentLine 2 SFP Temp High Warning :Warning indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE2…
1.3.6.1.4.1.20044.25.2.3.1.36.1.16Columnpm404AlmLine2RxPwrLowWngPortnread-onlycurrentLine 2 SFP Rx Power Low Warning :Warning indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> LIN…
1.3.6.1.4.1.20044.25.2.3.1.36.1.17Columnpm404AlmLine2RxPwrHighWngPortnread-onlycurrentLine 2 SFP Rx Power High Warning :Warning indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> L…
1.3.6.1.4.1.20044.25.2.3.2Nodepm404AlmLineUrg
1.3.6.1.4.1.20044.25.2.3.2.28Tablepm404Almline2SfpAlmDdmTablenot-accessiblecurrentList of pm404Almline2SfpAlmDdm Article
1.3.6.1.4.1.20044.25.2.3.2.28.1Rowpm404Almline2SfpAlmDdmEntrynot-accessiblecurrentRow definition for the pm404Almline2SfpAlmDdm table
1.3.6.1.4.1.20044.25.2.3.2.28.1.1Columnpm404Almline2SfpAlmDdmIndexread-onlycurrentIndex definition for the pm404Almline2SfpAlmDdm table
1.3.6.1.4.1.20044.25.2.3.2.28.1.2Columnpm404AlmLine2TxPwrLowAlaPortnread-onlycurrentLine 2 SFP Tx Power Low :Alarm indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE2_TX_PWR…
1.3.6.1.4.1.20044.25.2.3.2.28.1.3Columnpm404AlmLine2Line2TxPwrHighAlaPortnread-onlycurrentLine 2 SFP Tx Power High :Alarm indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE2_LINE…
1.3.6.1.4.1.20044.25.2.3.2.28.1.4Columnpm404AlmLine2TxBiasLowAlaPortnread-onlycurrentLine 2 SFP Bias Low :Alarm indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE2_TX_B…
1.3.6.1.4.1.20044.25.2.3.2.28.1.5Columnpm404AlmLine2TxBiasHighAlaPortnread-onlycurrentLine 2 SFP Bias High :Alarm indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE2_TX…
1.3.6.1.4.1.20044.25.2.3.2.28.1.6Columnpm404AlmLine2VccLowAlaPortnread-onlycurrentLine 2 SFP Power Supply Low :Alarm indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE2_VC…
1.3.6.1.4.1.20044.25.2.3.2.28.1.7Columnpm404AlmLine2VccHighAlaPortnread-onlycurrentLine 2 SFP Power Supply High :Alarm indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE2_…
1.3.6.1.4.1.20044.25.2.3.2.28.1.8Columnpm404AlmLine2TempLowAlaPortnread-onlycurrentLine 2 SFP Temp Low :Alarm indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE2_TEMP_LOW_AL…
1.3.6.1.4.1.20044.25.2.3.2.28.1.9Columnpm404AlmLine2TempHighAlaPortnread-onlycurrentLine 2 SFP Temp High :Alarm indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE2_TEMP_HIGH…
1.3.6.1.4.1.20044.25.2.3.2.28.1.16Columnpm404AlmLine2RxPwrLowAlaPortnread-onlycurrentLine 2 SFP Rx Power Low :Alarm indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE2_RX_PWR_…
1.3.6.1.4.1.20044.25.2.3.2.28.1.17Columnpm404AlmLine2RxPwrHighAlaPortnread-onlycurrentLine 2 SFP Rx Power High :Alarm indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE2_RX_PW…
1.3.6.1.4.1.20044.25.2.3.3Nodepm404AlmLineCrit
1.3.6.1.4.1.20044.25.2.3.3.12Tablepm404AlmsynthAlmLine2Tablenot-accessiblecurrentList of pm404AlmsynthAlmLine2 Article
1.3.6.1.4.1.20044.25.2.3.3.12.1Rowpm404AlmsynthAlmLine2Entrynot-accessiblecurrentRow definition for the pm404AlmsynthAlmLine2 table
1.3.6.1.4.1.20044.25.2.3.3.12.1.1Columnpm404AlmsynthAlmLine2Indexread-onlycurrentIndex definition for the pm404AlmsynthAlmLine2 table
1.3.6.1.4.1.20044.25.2.3.3.12.1.2Columnpm404AlmLine2SfpAbsentPortnread-onlycurrentLine 2 SFP Absent :This OID indicates that the SFP module is not present in the Line 2 port. <Help> This alarm indicates if the line 2 transceiver is present. …
1.3.6.1.4.1.20044.25.2.3.3.12.1.3Columnpm404AlmLine2DdmAbsentPortnread-onlycurrentDDM Supported On Line 2 SFP :This OID indicates that the Line 2 SFP module does not support the Digital Diagnostic Monitoring function <Help> This status indic…
1.3.6.1.4.1.20044.25.2.3.3.12.1.5Columnpm404AlmLine2HwFailPortnread-onlycurrentLine 2 HW Fail :This OID indicates a failure on Line 2 port, most probably caused by a HW issue. <Condtype> LINE2_HW_FAIL_A <Probcause> equipmentMalfunction (1…
1.3.6.1.4.1.20044.25.2.3.3.12.1.6Columnpm404AlmLine2LsdPortnread-onlycurrentLine 2 SFP Laser Shutdown :This OID indicates the Line 2 SFP transmitter output has shut down. <Help> This status indicates if the line 2 transceiver laser is …
1.3.6.1.4.1.20044.25.2.3.3.12.1.7Columnpm404AlmLine2LocalOosPortnread-onlycurrentLine 2 Port In Servicee :This OID indicates that the local Line 2 port is In Service (1) or Out of Service (2) <Help> This status indicates if the line port 2 …
1.3.6.1.4.1.20044.25.2.3.3.12.1.9Columnpm404AlmLine2DwCaisPortnread-onlycurrentLine 2 AIS Inserted :This OID indicates a CAIS has been inserted on the output Line 2 port. <Help> This status indicates if a Line Alarm Indication Signal is c…
1.3.6.1.4.1.20044.25.2.3.3.12.1.10Columnpm404AlmLine2DdmWarningPortnread-onlycurrentWarning On Line 2 SFP DDM :This OID indicates a warning is being received from the Line 2 SFP DDM <Help> This alarm indicates if a DDM Warning has been detecte…
1.3.6.1.4.1.20044.25.2.3.3.12.1.11Columnpm404AlmLine2DdmAlmPortnread-onlycurrentAlarm On Line 2 SFP DDM :This OID indicates an alarm is being received from the Line 2 SFP DDM <Help> This alarm indicates if a DDM Alarm has been detected on …
1.3.6.1.4.1.20044.25.2.3.3.12.1.13Columnpm404AlmLine2FailPortnread-onlycurrentLine 2 Access Fail :This OID indicates a failure on the Line 2 port <Condtype> LINE2_FAIL_A <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (1…
1.3.6.1.4.1.20044.25.2.3.3.20Tablepm404Almline2AccessioAlmTablenot-accessiblecurrentList of pm404Almline2AccessioAlm Article
1.3.6.1.4.1.20044.25.2.3.3.20.1Rowpm404Almline2AccessioAlmEntrynot-accessiblecurrentRow definition for the pm404Almline2AccessioAlm table
1.3.6.1.4.1.20044.25.2.3.3.20.1.1Columnpm404Almline2AccessioAlmIndexread-onlycurrentIndex definition for the pm404Almline2AccessioAlm table
1.3.6.1.4.1.20044.25.2.3.3.20.1.2Columnpm404AlmLine2LasFailPortnread-onlycurrentLine 2 SFP Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the Line 2 port (this alarm reports the transmitter failure alarm …
1.3.6.1.4.1.20044.25.2.3.3.20.1.5Columnpm404AlmLine2LosPortnread-onlycurrentLoss Of Optical Signal On Line 2 :This OID indicates that no signal is present on the SFP of the Line 2 port <Help> This alarm indicates if an optical signal i…
1.3.6.1.4.1.20044.25.2.3.3.20.1.7Columnpm404AlmLine2LosCdrPortnread-onlycurrentLoss Of Signal On CDR On Line 2 : <Condtype> LINE2_LOS_CDR_A <Probcause> receiveFailure (41) <Alarmtype> equipmentAlarm (5) <Polarity> (2)
1.3.6.1.4.1.20044.25.2.3.3.20.1.8Columnpm404AlmLine2ErrSigCdrPortnread-onlycurrentError Signal On CDR On Line 2 : <Condtype> LINE2__ERR_SIG_CDR_A <Probcause> receiveFailure (41) <Alarmtype> equipmentAlarm (5) <Polarity> (2)
1.3.6.1.4.1.20044.25.3Nodepm404measures
1.3.6.1.4.1.20044.25.3.1Nodepm404MesrOther
1.3.6.1.4.1.20044.25.3.2Nodepm404MesrClient
1.3.6.1.4.1.20044.25.3.2.16Tablepm404Mesrline1TemperatureTablenot-accessiblecurrentList of pm404Mesrline1Temperature Article
1.3.6.1.4.1.20044.25.3.2.16.1Rowpm404Mesrline1TemperatureEntrynot-accessiblecurrentRow definition for the pm404Mesrline1Temperature table
1.3.6.1.4.1.20044.25.3.2.16.1.1Columnpm404Mesrline1TemperatureIndexread-onlycurrentIndex definition for the pm404Mesrline1Temperature table
1.3.6.1.4.1.20044.25.3.2.16.1.2Columnpm404Mesrline1TemperaturePortnread-onlycurrentLine 1 SFP Temperature :This OID gives the temperature value of the SFP, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit = C) <H…
1.3.6.1.4.1.20044.25.3.2.24Tablepm404Mesrline1VoltTablenot-accessiblecurrentList of pm404Mesrline1Volt Article
1.3.6.1.4.1.20044.25.3.2.24.1Rowpm404Mesrline1VoltEntrynot-accessiblecurrentRow definition for the pm404Mesrline1Volt table
1.3.6.1.4.1.20044.25.3.2.24.1.1Columnpm404Mesrline1VoltIndexread-onlycurrentIndex definition for the pm404Mesrline1Volt table
1.3.6.1.4.1.20044.25.3.2.24.1.2Columnpm404Mesrline1VoltPortnread-onlycurrentLine 1 SFP Power Supply :This OID gives the 3V3 voltage value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/100…
1.3.6.1.4.1.20044.25.3.2.32Tablepm404Mesrline1TxBiasTablenot-accessiblecurrentList of pm404Mesrline1TxBias Article
1.3.6.1.4.1.20044.25.3.2.32.1Rowpm404Mesrline1TxBiasEntrynot-accessiblecurrentRow definition for the pm404Mesrline1TxBias table
1.3.6.1.4.1.20044.25.3.2.32.1.1Columnpm404Mesrline1TxBiasIndexread-onlycurrentIndex definition for the pm404Mesrline1TxBias table
1.3.6.1.4.1.20044.25.3.2.32.1.2Columnpm404Mesrline1TxBiasPortnread-onlycurrentLine 1 SFP Laser Bias :This OID gives the bias value of the SFP, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <Help> This meas…
1.3.6.1.4.1.20044.25.3.2.40Tablepm404Mesrline1TxPowerTablenot-accessiblecurrentList of pm404Mesrline1TxPower Article
1.3.6.1.4.1.20044.25.3.2.40.1Rowpm404Mesrline1TxPowerEntrynot-accessiblecurrentRow definition for the pm404Mesrline1TxPower table
1.3.6.1.4.1.20044.25.3.2.40.1.1Columnpm404Mesrline1TxPowerIndexread-onlycurrentIndex definition for the pm404Mesrline1TxPower table
1.3.6.1.4.1.20044.25.3.2.40.1.2Columnpm404Mesrline1TxPowerPortnread-onlycurrentLine 1 SFP Tx Power :This OID gives the transmit power value of the SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm)…
1.3.6.1.4.1.20044.25.3.2.48Tablepm404Mesrline1RxPowerTablenot-accessiblecurrentList of pm404Mesrline1RxPower Article
1.3.6.1.4.1.20044.25.3.2.48.1Rowpm404Mesrline1RxPowerEntrynot-accessiblecurrentRow definition for the pm404Mesrline1RxPower table
1.3.6.1.4.1.20044.25.3.2.48.1.1Columnpm404Mesrline1RxPowerIndexread-onlycurrentIndex definition for the pm404Mesrline1RxPower table
1.3.6.1.4.1.20044.25.3.2.48.1.2Columnpm404Mesrline1RxPowerPortnread-onlycurrentLine 1 SFP Rx Power :This OID gives the receive power value of the SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <H…
1.3.6.1.4.1.20044.25.3.3Nodepm404MesrLine
1.3.6.1.4.1.20044.25.3.3.20Tablepm404Mesrline2TemperatureTablenot-accessiblecurrentList of pm404Mesrline2Temperature Article
1.3.6.1.4.1.20044.25.3.3.20.1Rowpm404Mesrline2TemperatureEntrynot-accessiblecurrentRow definition for the pm404Mesrline2Temperature table
1.3.6.1.4.1.20044.25.3.3.20.1.1Columnpm404Mesrline2TemperatureIndexread-onlycurrentIndex definition for the pm404Mesrline2Temperature table
1.3.6.1.4.1.20044.25.3.3.20.1.2Columnpm404Mesrline2TemperaturePortnread-onlycurrentLine 2 SFP Temperature :This OID gives the temperature value of the SFP, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit = C) <H…
1.3.6.1.4.1.20044.25.3.3.28Tablepm404Mesrline2VoltTablenot-accessiblecurrentList of pm404Mesrline2Volt Article
1.3.6.1.4.1.20044.25.3.3.28.1Rowpm404Mesrline2VoltEntrynot-accessiblecurrentRow definition for the pm404Mesrline2Volt table
1.3.6.1.4.1.20044.25.3.3.28.1.1Columnpm404Mesrline2VoltIndexread-onlycurrentIndex definition for the pm404Mesrline2Volt table
1.3.6.1.4.1.20044.25.3.3.28.1.2Columnpm404Mesrline2VoltPortnread-onlycurrentLine 2 SFP Power Supply :This OID gives the 3V3 voltage value of the SFP, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/10000) (Unit = V) <He…
1.3.6.1.4.1.20044.25.3.3.36Tablepm404Mesrline2TxBiasTablenot-accessiblecurrentList of pm404Mesrline2TxBias Article
1.3.6.1.4.1.20044.25.3.3.36.1Rowpm404Mesrline2TxBiasEntrynot-accessiblecurrentRow definition for the pm404Mesrline2TxBias table
1.3.6.1.4.1.20044.25.3.3.36.1.1Columnpm404Mesrline2TxBiasIndexread-onlycurrentIndex definition for the pm404Mesrline2TxBias table
1.3.6.1.4.1.20044.25.3.3.36.1.2Columnpm404Mesrline2TxBiasPortnread-onlycurrentLine 2 SFP Laser Bias :This OID gives the bias value of the SFP, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <Help> This meas…
1.3.6.1.4.1.20044.25.3.3.44Tablepm404Mesrline2TxPowerTablenot-accessiblecurrentList of pm404Mesrline2TxPower Article
1.3.6.1.4.1.20044.25.3.3.44.1Rowpm404Mesrline2TxPowerEntrynot-accessiblecurrentRow definition for the pm404Mesrline2TxPower table
1.3.6.1.4.1.20044.25.3.3.44.1.1Columnpm404Mesrline2TxPowerIndexread-onlycurrentIndex definition for the pm404Mesrline2TxPower table
1.3.6.1.4.1.20044.25.3.3.44.1.2Columnpm404Mesrline2TxPowerPortnread-onlycurrentLine 2 SFP Tx Power :This OID gives the transmit power value of the SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm)…
1.3.6.1.4.1.20044.25.3.3.52Tablepm404Mesrline2RxPowerTablenot-accessiblecurrentList of pm404Mesrline2RxPower Article
1.3.6.1.4.1.20044.25.3.3.52.1Rowpm404Mesrline2RxPowerEntrynot-accessiblecurrentRow definition for the pm404Mesrline2RxPower table
1.3.6.1.4.1.20044.25.3.3.52.1.1Columnpm404Mesrline2RxPowerIndexread-onlycurrentIndex definition for the pm404Mesrline2RxPower table
1.3.6.1.4.1.20044.25.3.3.52.1.2Columnpm404Mesrline2RxPowerPortnread-onlycurrentLine 2 SFP Rx Power :This OID gives the receive power value of the SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <H…
1.3.6.1.4.1.20044.25.4Nodepm404counters
1.3.6.1.4.1.20044.25.4.1Nodepm404CntOther
1.3.6.1.4.1.20044.25.4.2Nodepm404CntClient
1.3.6.1.4.1.20044.25.4.3Nodepm404CntLine
1.3.6.1.4.1.20044.25.6Nodepm404controlsWrite
1.3.6.1.4.1.20044.25.6.1Nodepm404CtrlOther
1.3.6.1.4.1.20044.25.6.1.0Nodepm404Ctrlsynth0
1.3.6.1.4.1.20044.25.6.1.0.1Scalarpm404CtrlConfLoadread-writecurrentLoad Configuration Tables :When set this enables loading from flash configuration1 into the module.
1.3.6.1.4.1.20044.25.6.1.0.9Scalarpm404CtrlConfFlashread-writecurrentWrite Configuration Tables :This bit saves the current configuration of the module as configuration in the flash. <Help> This control saves the customer config…
1.3.6.1.4.1.20044.25.6.1.0.13Scalarpm404CtrlConfClearread-writecurrentClear Configuration Tables :This bit clears the configuration tables from configuration in the flash. <Help> This control restores the default configuration of…
1.3.6.1.4.1.20044.25.6.1.4Nodepm404Ctrlsynth4
1.3.6.1.4.1.20044.25.6.1.4.1Scalarpm404CtrlCorrelatOnread-writecurrentEnable Alarm Correlation :This OID enables the alarm correlation in the PM.
1.3.6.1.4.1.20044.25.6.1.4.2Scalarpm404CtrlCorrelatOffread-writecurrentDisable Alarm Correlation :This OID disables the alarm correlation in the PM.
1.3.6.1.4.1.20044.25.6.1.5Nodepm404CtrlswMgnt
1.3.6.1.4.1.20044.25.6.1.5.2Scalarpm404CtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the Software. This reset is traffic affecting, and the configuration of Software is reloaded on start…
1.3.6.1.4.1.20044.25.6.1.5.3Scalarpm404CtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the Software. This reset is not traffic affecting, and the configuration of the Sofwtare remains unch…
1.3.6.1.4.1.20044.25.6.1.72Nodepm404CtrlledTest
1.3.6.1.4.1.20044.25.6.1.72.1Scalarpm404CtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.25.6.1.72.2Scalarpm404CtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.25.6.1.72.3Scalarpm404CtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.25.6.1.73Nodepm404CtrlmoduleOosMode
1.3.6.1.4.1.20044.25.6.1.73.1Scalarpm404CtrlModuleOosModeread-writecurrentPM Out Of Service :This OID sets the PM Out Of Service <Help> This control defines the service state of the complete module
1.3.6.1.4.1.20044.25.6.2Nodepm404CtrlClient
1.3.6.1.4.1.20044.25.6.2.16Tablepm404Ctrlline1SfpOnoffTablenot-accessiblecurrentList of pm404Ctrlline1SfpOnoff Article
1.3.6.1.4.1.20044.25.6.2.16.1Rowpm404Ctrlline1SfpOnoffEntrynot-accessiblecurrentRow definition for the pm404Ctrlline1SfpOnoff table
1.3.6.1.4.1.20044.25.6.2.16.1.1Columnpm404Ctrlline1SfpOnoffIndexread-onlycurrentIndex definition for the pm404Ctrlline1SfpOnoff table
1.3.6.1.4.1.20044.25.6.2.16.1.2Columnpm404Ctrlline1SfpOnoffPortnread-writecurrentLine 1 SFP Laser Shutdown :This OID switches off the SFP <Help> This control defines the laser state of the line 1 transceiver
1.3.6.1.4.1.20044.25.6.2.17Tablepm404Ctrlline1LoopbackTablenot-accessiblecurrentList of pm404Ctrlline1Loopback Article
1.3.6.1.4.1.20044.25.6.2.17.1Rowpm404Ctrlline1LoopbackEntrynot-accessiblecurrentRow definition for the pm404Ctrlline1Loopback table
1.3.6.1.4.1.20044.25.6.2.17.1.1Columnpm404Ctrlline1LoopbackIndexread-onlycurrentIndex definition for the pm404Ctrlline1Loopback table
1.3.6.1.4.1.20044.25.6.2.17.1.2Columnpm404Ctrlline1LoopbackPortnread-writecurrentLine 1 Facility Loopback :This OID operates a Client Facility Loopback, looping client input signal on the client output port. The loop is located on the clien…
1.3.6.1.4.1.20044.25.6.2.18Tablepm404Ctrlline1LoopbackTermTablenot-accessiblecurrentList of pm404Ctrlline1LoopbackTerm Article
1.3.6.1.4.1.20044.25.6.2.18.1Rowpm404Ctrlline1LoopbackTermEntrynot-accessiblecurrentRow definition for the pm404Ctrlline1LoopbackTerm table
1.3.6.1.4.1.20044.25.6.2.18.1.1Columnpm404Ctrlline1LoopbackTermIndexread-onlycurrentIndex definition for the pm404Ctrlline1LoopbackTerm table
1.3.6.1.4.1.20044.25.6.2.18.1.2Columnpm404Ctrlline1LoopbackTermPortnread-writecurrentLine 1 Terminal Loopback :This OID operates a Client Terminal Loopback, looping client input signal on the client output port. The loop is located on the line …
1.3.6.1.4.1.20044.25.6.2.20Tablepm404Ctrlline1OosModeTablenot-accessiblecurrentList of pm404Ctrlline1OosMode Article
1.3.6.1.4.1.20044.25.6.2.20.1Rowpm404Ctrlline1OosModeEntrynot-accessiblecurrentRow definition for the pm404Ctrlline1OosMode table
1.3.6.1.4.1.20044.25.6.2.20.1.1Columnpm404Ctrlline1OosModeIndexread-onlycurrentIndex definition for the pm404Ctrlline1OosMode table
1.3.6.1.4.1.20044.25.6.2.20.1.2Columnpm404Ctrlline1OosModePortnread-writecurrentLine 1 Port Out Of Service :This OID sets the port Out Of Service <Help> This controls defines the service state of the line 1 port
1.3.6.1.4.1.20044.25.6.2.48Tablepm404CtrlprotocolTablenot-accessiblecurrentList of pm404Ctrlprotocol Article
1.3.6.1.4.1.20044.25.6.2.48.1Rowpm404CtrlprotocolEntrynot-accessiblecurrentRow definition for the pm404Ctrlprotocol table
1.3.6.1.4.1.20044.25.6.2.48.1.1Columnpm404CtrlprotocolIndexread-onlycurrentIndex definition for the pm404Ctrlprotocol table
1.3.6.1.4.1.20044.25.6.2.48.1.2Columnpm404CtrlprotocolPortnread-writecurrentLines Bitrate: This OID sets the protocol of the lines port.
1.3.6.1.4.1.20044.25.6.3Nodepm404CtrlLine
1.3.6.1.4.1.20044.25.6.3.64Tablepm404Ctrlline2SfpOnoffTablenot-accessiblecurrentList of pm404Ctrlline2SfpOnoff Article
1.3.6.1.4.1.20044.25.6.3.64.1Rowpm404Ctrlline2SfpOnoffEntrynot-accessiblecurrentRow definition for the pm404Ctrlline2SfpOnoff table
1.3.6.1.4.1.20044.25.6.3.64.1.1Columnpm404Ctrlline2SfpOnoffIndexread-onlycurrentIndex definition for the pm404Ctrlline2SfpOnoff table
1.3.6.1.4.1.20044.25.6.3.64.1.2Columnpm404Ctrlline2SfpOnoffPortnread-writecurrentLine 2 SFP Laser Shutdown :This OID switches off the SFP <Help> This control defines the laser state of the line 2 transceiver
1.3.6.1.4.1.20044.25.6.3.65Tablepm404Ctrlline2OosModeTablenot-accessiblecurrentList of pm404Ctrlline2OosMode Article
1.3.6.1.4.1.20044.25.6.3.65.1Rowpm404Ctrlline2OosModeEntrynot-accessiblecurrentRow definition for the pm404Ctrlline2OosMode table
1.3.6.1.4.1.20044.25.6.3.65.1.1Columnpm404Ctrlline2OosModeIndexread-onlycurrentIndex definition for the pm404Ctrlline2OosMode table
1.3.6.1.4.1.20044.25.6.3.65.1.2Columnpm404Ctrlline2OosModePortnread-writecurrentLine 2 Port Out Of Service :This OID sets the port Out Of Service <Help> This controls defines the service state of the line 2 port
1.3.6.1.4.1.20044.25.6.3.66Tablepm404Ctrlline2LoopbackTablenot-accessiblecurrentList of pm404Ctrlline2Loopback Article
1.3.6.1.4.1.20044.25.6.3.66.1Rowpm404Ctrlline2LoopbackEntrynot-accessiblecurrentRow definition for the pm404Ctrlline2Loopback table
1.3.6.1.4.1.20044.25.6.3.66.1.1Columnpm404Ctrlline2LoopbackIndexread-onlycurrentIndex definition for the pm404Ctrlline2Loopback table
1.3.6.1.4.1.20044.25.6.3.66.1.2Columnpm404Ctrlline2LoopbackPortnread-writecurrentLine 2 Facility Loopback :This OID operates a Line Facility Loopback, looping line input signal on the line output port. The loop is located on the line transc…
1.3.6.1.4.1.20044.25.6.3.67Tablepm404Ctrlline2LoopbackTermTablenot-accessiblecurrentList of pm404Ctrlline2LoopbackTerm Article
1.3.6.1.4.1.20044.25.6.3.67.1Rowpm404Ctrlline2LoopbackTermEntrynot-accessiblecurrentRow definition for the pm404Ctrlline2LoopbackTerm table
1.3.6.1.4.1.20044.25.6.3.67.1.1Columnpm404Ctrlline2LoopbackTermIndexread-onlycurrentIndex definition for the pm404Ctrlline2LoopbackTerm table
1.3.6.1.4.1.20044.25.6.3.67.1.2Columnpm404Ctrlline2LoopbackTermPortnread-writecurrentLine 2 Terminal Loopback :This OID operates a Line Terminal Loopback, looping line input signal on the line output port. The loop is located on all client tran…
1.3.6.1.4.1.20044.25.7Nodepm404ri
1.3.6.1.4.1.20044.25.7.1Nodepm404riTable
1.3.6.1.4.1.20044.25.7.1.1Tablepm404RinvLine1Tablenot-accessiblecurrentList of the SFPs on the selected module
1.3.6.1.4.1.20044.25.7.1.1.1Rowpm404RinvLine1Entrynot-accessiblecurrentRow definition for the Line1 SFP table
1.3.6.1.4.1.20044.25.7.1.1.1.1Columnpm404RinvLine1Indexread-onlycurrentIndex for Line1 SFP table
1.3.6.1.4.1.20044.25.7.1.1.1.2Columnpm404RinvSfpLine1read-onlycurrentInventory for the SFP: This OID contains the inventory for the Line1 SFP
1.3.6.1.4.1.20044.25.7.1.2Tablepm404RinvLine2Tablenot-accessiblecurrentList of the SFPs on the selected module
1.3.6.1.4.1.20044.25.7.1.2.1Rowpm404RinvLine2Entrynot-accessiblecurrentRow definition for the Line SFP table
1.3.6.1.4.1.20044.25.7.1.2.1.1Columnpm404RinvLine2Indexread-onlycurrentIndex for SFP table
1.3.6.1.4.1.20044.25.7.1.2.1.2Columnpm404RinvsfpLine2read-onlycurrentInventory for the SFP: This OID contains the inventory for the Line2 SFP
1.3.6.1.4.1.20044.25.7.2Scalarpm404RinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.25.7.3Scalarpm404RinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.25.7.4Scalarpm404RinvModulePlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.25.7.5Scalarpm404RinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.25.7.6Scalarpm404RinvGwPlatformread-onlycurrentGW platform desciption: This OID contains the description of the Gateware platform.
1.3.6.1.4.1.20044.25.9Nodepm404Config
1.3.6.1.4.1.20044.25.9.1Nodepm404CfgLsd
1.3.6.1.4.1.20044.25.9.1.1Tablepm404CfgLine1LsdTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.25.9.1.1.1Rowpm404CfgLine1LsdEntrynot-accessiblecurrentRow definition for the lsd table
1.3.6.1.4.1.20044.25.9.1.1.1.1Columnpm404CfgLine1LsdIndexread-onlycurrentIndex definition for the line1Lsd table
1.3.6.1.4.1.20044.25.9.1.1.1.3Columnpm404CfgLine1LsdModePortnread-writecurrentCAIS mode on Lines Port :This register selects the way to activate the laser upon CAIS/CSF criteria detection on Port
1.3.6.1.4.1.20044.25.9.1.1.1.4Columnpm404CfgLine1AccessioCtrbInsPortnread-writecurrentCAIS contributors on Line 1 Port :This register selects the contributors to upstream CAIS/CSF on Port
1.3.6.1.4.1.20044.25.9.1.1.1.7Columnpm404CfgLine2AccessioCtrbInsPortnread-writecurrentCAIS contributors on Lne 2 Port :This register selects the contributors to downstream CAIS/CSF on Port
1.3.6.1.4.1.20044.25.9.2Nodepm404CfgStartUp
1.3.6.1.4.1.20044.25.9.2.1Tablepm404CfgLine1StartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.25.9.2.1.1Rowpm404CfgLine1StartupEntrynot-accessiblecurrentRow definition for the startUp table
1.3.6.1.4.1.20044.25.9.2.1.1.1Columnpm404CfgLine1StartupIndexread-onlycurrentIndex definition for the line1Startup table
1.3.6.1.4.1.20044.25.9.2.1.1.3Columnpm404CfgLine1TrscvCtrlPortnread-writecurrentDefault Settings on Line 1 TRSCV :This register configures the default initialisation settings on client transceiver.
1.3.6.1.4.1.20044.25.9.2.1.1.4Columnpm404CfgLine1ProtocolPortnread-writecurrentDefault Protocol on Line 1 :This register configures the default initialisation protocol on the port.
1.3.6.1.4.1.20044.25.9.2.1.1.5Columnpm404CfgLine1OosModePortnread-writecurrentDefault Settings on Line 1 TRSCV :This register configures the default initialisation settings on client transceiver.
1.3.6.1.4.1.20044.25.9.2.2Tablepm404CfgLine2StartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.25.9.2.2.1Rowpm404CfgLine2StartupEntrynot-accessiblecurrentRow definition for the startUp table
1.3.6.1.4.1.20044.25.9.2.2.1.1Columnpm404CfgLine2StartupIndexread-onlycurrentIndex definition for the line2Startup table
1.3.6.1.4.1.20044.25.9.2.2.1.3Columnpm404CfgLine2TrscvCtrlPortnread-writecurrentDefault Settings on Line 2 TRSCV :This register configures the default initialisation settings on line transceiver.
1.3.6.1.4.1.20044.25.9.2.2.1.4Columnpm404CfgLine2OosModePortnread-writecurrentDefault Settings on Line 2 TRSCV :This register configures the default initialisation settings on line transceiver.
1.3.6.1.4.1.20044.25.9.3Nodepm404CfgLabels
1.3.6.1.4.1.20044.25.9.3.1Tablepm404CfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.25.9.3.1.1Rowpm404CfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.25.9.3.1.1.1Columnpm404CfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.25.9.3.1.1.3Columnpm404CfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.25.9.3.2Tablepm404CfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.25.9.3.2.1Rowpm404CfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.25.9.3.2.1.1Columnpm404CfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.25.9.3.2.1.3Columnpm404CfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.25.9.257Scalarpm404CfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.25.10Nodepm404traps
1.3.6.1.4.1.20044.25.10.2Scalarpm404trapPortNumberread-onlycurrentLast port which generates a trap
1.3.6.1.4.1.20044.25.10.3Scalarpm404trapLineNumberread-onlycurrentLast Line which generates a trap
1.3.6.1.4.1.20044.25.10.4Scalarpm404trapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.25.10.30Notificationpm404Line2TrapNotUrgentGoesOncurrentNot urgent Line default is activated
1.3.6.1.4.1.20044.25.10.31Notificationpm404Line2TrapNotUrgentGoesOffcurrentNot urgent Line default disappeared
1.3.6.1.4.1.20044.25.10.32Notificationpm404Line2TrapUrgentGoesOncurrentUrgent Line default is activated
1.3.6.1.4.1.20044.25.10.33Notificationpm404Line2TrapUrgentGoesOffcurrentUrgent Line default disappeared
1.3.6.1.4.1.20044.25.10.34Notificationpm404Line2TrapCritGoesOncurrentCritical Line default is activated
1.3.6.1.4.1.20044.25.10.35Notificationpm404Line2TrapCritGoesOffcurrentCritical Line default disappeared
1.3.6.1.4.1.20044.25.10.40Notificationpm404Line1TrapNotUrgentGoesOncurrentNot urgent client default is activated
1.3.6.1.4.1.20044.25.10.41Notificationpm404Line1TrapNotUrgentGoesOffcurrentNot urgent client default disappeared
1.3.6.1.4.1.20044.25.10.42Notificationpm404Line1TrapUrgentGoesOncurrentUrgent client default is activated
1.3.6.1.4.1.20044.25.10.43Notificationpm404Line1TrapUrgentGoesOffcurrentUrgent client default disappeared
1.3.6.1.4.1.20044.25.10.44Notificationpm404Line1TrapCritGoesOncurrentCritical client default is activated
1.3.6.1.4.1.20044.25.10.45Notificationpm404Line1TrapCritGoesOffcurrentCritical client default disappeared
1.3.6.1.4.1.20044.25.10.50Notificationpm404PowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.25.10.51Notificationpm404PowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared