EKINOPS-Pm404-MIB
280 objects
MIB for the Ekinops Pm404 hardware.
Imported Objects
| EKINOPS-MIB | EkiApiState EkiMeasureType EkiMode ekinops EkiOnOff EkiProtocol EkiState EkiSynchroMode |
| SNMPv2-SMI | Counter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20044.25 | IdentitymodulePm404 | MIB for the Ekinops Pm404 hardware. | ||
| 1.3.6.1.4.1.20044.25.2 | Nodepm404alarms | |||
| 1.3.6.1.4.1.20044.25.2.1 | Nodepm404AlmOther | |||
| 1.3.6.1.4.1.20044.25.2.1.1 | Nodepm404AlmOtherNurg | |||
| 1.3.6.1.4.1.20044.25.2.1.1.2 | Nodepm404AlmsynthAlm2 | |||
| 1.3.6.1.4.1.20044.25.2.1.1.2.1 | Scalarpm404AlmConfTableSave | read-only | current | PM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> other… |
| 1.3.6.1.4.1.20044.25.2.1.1.2.2 | Scalarpm404AlmInvUpload | read-only | current | Inventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> other (1) <Alarmtype> other (1) <Polarit… |
| 1.3.6.1.4.1.20044.25.2.1.1.2.3 | Scalarpm404AlmConfTableLoad | read-only | current | PM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> other (1) <Alarmt… |
| 1.3.6.1.4.1.20044.25.2.1.1.2.4 | Scalarpm404AlmCorrelatOff | read-only | current | Not Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> other (1) <Alarmtype> other (1) <Pol… |
| 1.3.6.1.4.1.20044.25.2.1.2 | Nodepm404AlmOtherUrg | |||
| 1.3.6.1.4.1.20044.25.2.1.3 | Nodepm404AlmOtherCrit | |||
| 1.3.6.1.4.1.20044.25.2.1.3.0 | Nodepm404AlmsynthAlm0 | |||
| 1.3.6.1.4.1.20044.25.2.1.3.0.9 | Scalarpm404AlmModuleGlobFailure | read-only | current | Module Failure :This OID is set on detection of a failure originating from the PM <Condtype> MODULE_GLOB_FAILURE <Probcause> equipmentMalfunction (16) <Alarmty… |
| 1.3.6.1.4.1.20044.25.2.1.3.0.15 | Scalarpm404AlmDefFuseA | read-only | current | Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.25.2.1.3.0.16 | Scalarpm404AlmDefFuseB | read-only | current | Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.25.2.2 | Nodepm404AlmClient | |||
| 1.3.6.1.4.1.20044.25.2.2.1 | Nodepm404AlmClientNurg | |||
| 1.3.6.1.4.1.20044.25.2.2.1.32 | Tablepm404Almline1SfpWarnDdmTable | not-accessible | current | List of pm404Almline1SfpWarnDdm Article |
| 1.3.6.1.4.1.20044.25.2.2.1.32.1 | Rowpm404Almline1SfpWarnDdmEntry | not-accessible | current | Row definition for the pm404Almline1SfpWarnDdm table |
| 1.3.6.1.4.1.20044.25.2.2.1.32.1.1 | Columnpm404Almline1SfpWarnDdmIndex | read-only | current | Index definition for the pm404Almline1SfpWarnDdm table |
| 1.3.6.1.4.1.20044.25.2.2.1.32.1.2 | Columnpm404AlmLine1TxPwLowWngPortn | read-only | current | Line 1 SFP Tx Power Low Warning :Warning indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> LI… |
| 1.3.6.1.4.1.20044.25.2.2.1.32.1.3 | Columnpm404AlmLine1TxPwrHighWngPortn | read-only | current | Line 1 SFP Tx Power High Warning :Warning indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> … |
| 1.3.6.1.4.1.20044.25.2.2.1.32.1.4 | Columnpm404AlmLine1TxBiasLowWngPortn | read-only | current | Line 1 SFP Bias Low Warning :Warning indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> … |
| 1.3.6.1.4.1.20044.25.2.2.1.32.1.5 | Columnpm404AlmLine1TxBiasHighWngPortn | read-only | current | Line 1 SFP Bias High Warning :Warning indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype… |
| 1.3.6.1.4.1.20044.25.2.2.1.32.1.6 | Columnpm404AlmLine1VccLowWngPortn | read-only | current | Line 1 SFP Power Supply Low Warning :Warning indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype… |
| 1.3.6.1.4.1.20044.25.2.2.1.32.1.7 | Columnpm404AlmLine1VccHighWngPortn | read-only | current | Line 1 SFP Power Supply High Warning :Warning indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condty… |
| 1.3.6.1.4.1.20044.25.2.2.1.32.1.8 | Columnpm404AlmLine1TempLowWngPortn | read-only | current | Line 1 SFP Temp Low Warning :Warning indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE1_T… |
| 1.3.6.1.4.1.20044.25.2.2.1.32.1.9 | Columnpm404AlmLine1TempHighWngPortn | read-only | current | Line 1 SFP Temp High Warning :Warning indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE1… |
| 1.3.6.1.4.1.20044.25.2.2.1.32.1.16 | Columnpm404AlmLine1RxPwrLowWngPortn | read-only | current | Line 1 SFP Rx Power Low Warning :Warning indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> LIN… |
| 1.3.6.1.4.1.20044.25.2.2.1.32.1.17 | Columnpm404AlmLine1RxPwrHighWngPortn | read-only | current | Line 1 SFP Rx Power High Warning :Warning indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> L… |
| 1.3.6.1.4.1.20044.25.2.2.2 | Nodepm404AlmClientUrg | |||
| 1.3.6.1.4.1.20044.25.2.2.2.24 | Tablepm404Almline1SfpAlmDdmTable | not-accessible | current | List of pm404Almline1SfpAlmDdm Article |
| 1.3.6.1.4.1.20044.25.2.2.2.24.1 | Rowpm404Almline1SfpAlmDdmEntry | not-accessible | current | Row definition for the pm404Almline1SfpAlmDdm table |
| 1.3.6.1.4.1.20044.25.2.2.2.24.1.1 | Columnpm404Almline1SfpAlmDdmIndex | read-only | current | Index definition for the pm404Almline1SfpAlmDdm table |
| 1.3.6.1.4.1.20044.25.2.2.2.24.1.2 | Columnpm404AlmLine1TxPwrLowAlaPortn | read-only | current | Line 1 SFP Tx Power Low :Alarm indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE1_TX_PWR… |
| 1.3.6.1.4.1.20044.25.2.2.2.24.1.3 | Columnpm404AlmLine1Line1TxPwrHighAlaPortn | read-only | current | Line 1 SFP Tx Power High :Alarm indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE1_LINE… |
| 1.3.6.1.4.1.20044.25.2.2.2.24.1.4 | Columnpm404AlmLine1TxBiasLowAlaPortn | read-only | current | Line 1 SFP Bias Low :Alarm indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE1_TX_B… |
| 1.3.6.1.4.1.20044.25.2.2.2.24.1.5 | Columnpm404AlmLine1TxBiasHighAlaPortn | read-only | current | Line 1 SFP Bias High :Alarm indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE1_TX… |
| 1.3.6.1.4.1.20044.25.2.2.2.24.1.6 | Columnpm404AlmLine1VccLowAlaPortn | read-only | current | Line 1 SFP Power Supply Low :Alarm indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE1_VC… |
| 1.3.6.1.4.1.20044.25.2.2.2.24.1.7 | Columnpm404AlmLine1VccHighAlaPortn | read-only | current | Line 1 SFP Power Supply High :Alarm indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE1_… |
| 1.3.6.1.4.1.20044.25.2.2.2.24.1.8 | Columnpm404AlmLine1TempLowAlaPortn | read-only | current | Line 1 SFP Temp Low :Alarm indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE1_TEMP_LOW_AL… |
| 1.3.6.1.4.1.20044.25.2.2.2.24.1.9 | Columnpm404AlmLine1TempHighAlaPortn | read-only | current | Line 1 SFP Temp High :Alarm indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE1_TEMP_HIGH… |
| 1.3.6.1.4.1.20044.25.2.2.2.24.1.16 | Columnpm404AlmLine1RxPwrLowAlaPortn | read-only | current | Line 1 SFP Rx Power Low :Alarm indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE1_RX_PWR_… |
| 1.3.6.1.4.1.20044.25.2.2.2.24.1.17 | Columnpm404AlmLine1RxPwrHighAlaPortn | read-only | current | Line 1 SFP Rx Power High :Alarm indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE1_RX_PW… |
| 1.3.6.1.4.1.20044.25.2.2.3 | Nodepm404AlmClientCrit | |||
| 1.3.6.1.4.1.20044.25.2.2.3.8 | Tablepm404AlmsynthAlmLine1Table | not-accessible | current | List of pm404AlmsynthAlmLine1 Article |
| 1.3.6.1.4.1.20044.25.2.2.3.8.1 | Rowpm404AlmsynthAlmLine1Entry | not-accessible | current | Row definition for the pm404AlmsynthAlmLine1 table |
| 1.3.6.1.4.1.20044.25.2.2.3.8.1.1 | Columnpm404AlmsynthAlmLine1Index | read-only | current | Index definition for the pm404AlmsynthAlmLine1 table |
| 1.3.6.1.4.1.20044.25.2.2.3.8.1.2 | Columnpm404AlmLine1SfpAbsentPortn | read-only | current | Line 1 SFP Absent :This OID indicates that the SFP module is not present in the Line 1 port. <Help> This alarm indicates if the line 1 transceiver is present. … |
| 1.3.6.1.4.1.20044.25.2.2.3.8.1.3 | Columnpm404AlmLine1DdmAbsentPortn | read-only | current | DDM Supported On Line 1 SFP :This OID indicates that the Line 1 SFP module does not support the Digital Diagnostic Monitoring function <Help> This status indic… |
| 1.3.6.1.4.1.20044.25.2.2.3.8.1.5 | Columnpm404AlmLine1HwFailAccPortn | read-only | current | Line 1 HW Fail :This OID indicates a failure on Line 1 port, most probably caused by a HW issue. <Condtype> LINE1_HW_FAIL_ACC_A <Probcause> equipmentMalfunctio… |
| 1.3.6.1.4.1.20044.25.2.2.3.8.1.6 | Columnpm404AlmLine1LsdPortn | read-only | current | Line 1 SFP Laser Shutdown :This OID indicates the Line 1 SFP transmitter output has shut down. <Help> This status indicates if the line 1 transceiver laser is … |
| 1.3.6.1.4.1.20044.25.2.2.3.8.1.7 | Columnpm404AlmLine1LocalOosPortn | read-only | current | Line 1 Port In Service :This OID indicates that the local Line 1 port is In Service (1) or Out of Service (2) <Help> This status indicates if the line port 1 i… |
| 1.3.6.1.4.1.20044.25.2.2.3.8.1.9 | Columnpm404AlmLine1DwCaisPortn | read-only | current | Line 1 AIS Inserted :This OID indicates a CAIS has been inserted on the output Line 1 port. <Help> This status indicates if a Line Alarm Indication Signal is c… |
| 1.3.6.1.4.1.20044.25.2.2.3.8.1.10 | Columnpm404AlmLine1SfpDdmWarningPortn | read-only | current | Warning On Line 1 SFP DDM :This OID indicates a warning is being received from the Line 1 SFP DDM <Help> This alarm indicates if a DDM Warning has been detecte… |
| 1.3.6.1.4.1.20044.25.2.2.3.8.1.11 | Columnpm404AlmLine1SfpDdmAlmPortn | read-only | current | Alarm On Line 1 SFP DDM :This OID indicates an alarm is being received from the Line 1 SFP DDM <Help> This alarm indicates if a DDM Alarm has been detected on … |
| 1.3.6.1.4.1.20044.25.2.2.3.8.1.13 | Columnpm404AlmLine1FailAccPortn | read-only | current | Line 1 Access Fail :This OID indicates a failure on the Line 1 port <Condtype> LINE1_FAIL_ACC_A <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlar… |
| 1.3.6.1.4.1.20044.25.2.2.3.16 | Tablepm404Almline1AccessioAlmTable | not-accessible | current | List of pm404Almline1AccessioAlm Article |
| 1.3.6.1.4.1.20044.25.2.2.3.16.1 | Rowpm404Almline1AccessioAlmEntry | not-accessible | current | Row definition for the pm404Almline1AccessioAlm table |
| 1.3.6.1.4.1.20044.25.2.2.3.16.1.1 | Columnpm404Almline1AccessioAlmIndex | read-only | current | Index definition for the pm404Almline1AccessioAlm table |
| 1.3.6.1.4.1.20044.25.2.2.3.16.1.2 | Columnpm404AlmLine1LasFailPortn | read-only | current | Line 1 SFP Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the Line 1 port (this alarm reports the transmitter failure alarm … |
| 1.3.6.1.4.1.20044.25.2.2.3.16.1.5 | Columnpm404AlmLine1LosPortn | read-only | current | Loss Of Optical Signal On Line 1 :This OID indicates that no signal is present on the SFP of the Line 1 port <Help> This alarm indicates if an optical signal i… |
| 1.3.6.1.4.1.20044.25.2.2.3.16.1.7 | Columnpm404AlmLine1LosCdrPortn | read-only | current | Loss Of Signal On CDR On Line 1 : <Condtype> LINE1_LOS_CDR_A <Probcause> receiveFailure (41) <Alarmtype> equipmentAlarm (5) <Polarity> (2) |
| 1.3.6.1.4.1.20044.25.2.2.3.16.1.8 | Columnpm404AlmLine1ErrSigCdrPortn | read-only | current | Error Signal On CDR On Line 1 : <Condtype> LINE1__ERR_SIG_CDR_A <Probcause> receiveFailure (41) <Alarmtype> equipmentAlarm (5) <Polarity> (2) |
| 1.3.6.1.4.1.20044.25.2.3 | Nodepm404AlmLine | |||
| 1.3.6.1.4.1.20044.25.2.3.1 | Nodepm404AlmLineNurg | |||
| 1.3.6.1.4.1.20044.25.2.3.1.36 | Tablepm404Almline2SfpWarnDdmTable | not-accessible | current | List of pm404Almline2SfpWarnDdm Article |
| 1.3.6.1.4.1.20044.25.2.3.1.36.1 | Rowpm404Almline2SfpWarnDdmEntry | not-accessible | current | Row definition for the pm404Almline2SfpWarnDdm table |
| 1.3.6.1.4.1.20044.25.2.3.1.36.1.1 | Columnpm404Almline2SfpWarnDdmIndex | read-only | current | Index definition for the pm404Almline2SfpWarnDdm table |
| 1.3.6.1.4.1.20044.25.2.3.1.36.1.2 | Columnpm404AlmLine2TxPwLowWngPortn | read-only | current | Line 2 SFP Tx Power Low Warning :Warning indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> LI… |
| 1.3.6.1.4.1.20044.25.2.3.1.36.1.3 | Columnpm404AlmLine2TxPwrHighWngPortn | read-only | current | Line 2 SFP Tx Power High Warning :Warning indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> … |
| 1.3.6.1.4.1.20044.25.2.3.1.36.1.4 | Columnpm404AlmLine2TxBiasLowWngPortn | read-only | current | Line 2 SFP Bias Low Warning :Warning indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> … |
| 1.3.6.1.4.1.20044.25.2.3.1.36.1.5 | Columnpm404AlmLine2TxBiasHighWngPortn | read-only | current | Line 2 SFP Bias High Warning :Warning indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype… |
| 1.3.6.1.4.1.20044.25.2.3.1.36.1.6 | Columnpm404AlmLine2VccLowWngPortn | read-only | current | Line 2 SFP Power Supply Low Warning :Warning indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype… |
| 1.3.6.1.4.1.20044.25.2.3.1.36.1.7 | Columnpm404AlmLine2VccHighWngPortn | read-only | current | Line 2 SFP Power Supply High Warning :Warning indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condty… |
| 1.3.6.1.4.1.20044.25.2.3.1.36.1.8 | Columnpm404AlmLine2TempLowWngPortn | read-only | current | Line 2 SFP Temp Low Warning :Warning indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE2_T… |
| 1.3.6.1.4.1.20044.25.2.3.1.36.1.9 | Columnpm404AlmLine2TempHighWngPortn | read-only | current | Line 2 SFP Temp High Warning :Warning indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE2… |
| 1.3.6.1.4.1.20044.25.2.3.1.36.1.16 | Columnpm404AlmLine2RxPwrLowWngPortn | read-only | current | Line 2 SFP Rx Power Low Warning :Warning indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> LIN… |
| 1.3.6.1.4.1.20044.25.2.3.1.36.1.17 | Columnpm404AlmLine2RxPwrHighWngPortn | read-only | current | Line 2 SFP Rx Power High Warning :Warning indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> L… |
| 1.3.6.1.4.1.20044.25.2.3.2 | Nodepm404AlmLineUrg | |||
| 1.3.6.1.4.1.20044.25.2.3.2.28 | Tablepm404Almline2SfpAlmDdmTable | not-accessible | current | List of pm404Almline2SfpAlmDdm Article |
| 1.3.6.1.4.1.20044.25.2.3.2.28.1 | Rowpm404Almline2SfpAlmDdmEntry | not-accessible | current | Row definition for the pm404Almline2SfpAlmDdm table |
| 1.3.6.1.4.1.20044.25.2.3.2.28.1.1 | Columnpm404Almline2SfpAlmDdmIndex | read-only | current | Index definition for the pm404Almline2SfpAlmDdm table |
| 1.3.6.1.4.1.20044.25.2.3.2.28.1.2 | Columnpm404AlmLine2TxPwrLowAlaPortn | read-only | current | Line 2 SFP Tx Power Low :Alarm indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE2_TX_PWR… |
| 1.3.6.1.4.1.20044.25.2.3.2.28.1.3 | Columnpm404AlmLine2Line2TxPwrHighAlaPortn | read-only | current | Line 2 SFP Tx Power High :Alarm indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE2_LINE… |
| 1.3.6.1.4.1.20044.25.2.3.2.28.1.4 | Columnpm404AlmLine2TxBiasLowAlaPortn | read-only | current | Line 2 SFP Bias Low :Alarm indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE2_TX_B… |
| 1.3.6.1.4.1.20044.25.2.3.2.28.1.5 | Columnpm404AlmLine2TxBiasHighAlaPortn | read-only | current | Line 2 SFP Bias High :Alarm indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE2_TX… |
| 1.3.6.1.4.1.20044.25.2.3.2.28.1.6 | Columnpm404AlmLine2VccLowAlaPortn | read-only | current | Line 2 SFP Power Supply Low :Alarm indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE2_VC… |
| 1.3.6.1.4.1.20044.25.2.3.2.28.1.7 | Columnpm404AlmLine2VccHighAlaPortn | read-only | current | Line 2 SFP Power Supply High :Alarm indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE2_… |
| 1.3.6.1.4.1.20044.25.2.3.2.28.1.8 | Columnpm404AlmLine2TempLowAlaPortn | read-only | current | Line 2 SFP Temp Low :Alarm indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE2_TEMP_LOW_AL… |
| 1.3.6.1.4.1.20044.25.2.3.2.28.1.9 | Columnpm404AlmLine2TempHighAlaPortn | read-only | current | Line 2 SFP Temp High :Alarm indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE2_TEMP_HIGH… |
| 1.3.6.1.4.1.20044.25.2.3.2.28.1.16 | Columnpm404AlmLine2RxPwrLowAlaPortn | read-only | current | Line 2 SFP Rx Power Low :Alarm indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> LINE2_RX_PWR_… |
| 1.3.6.1.4.1.20044.25.2.3.2.28.1.17 | Columnpm404AlmLine2RxPwrHighAlaPortn | read-only | current | Line 2 SFP Rx Power High :Alarm indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> LINE2_RX_PW… |
| 1.3.6.1.4.1.20044.25.2.3.3 | Nodepm404AlmLineCrit | |||
| 1.3.6.1.4.1.20044.25.2.3.3.12 | Tablepm404AlmsynthAlmLine2Table | not-accessible | current | List of pm404AlmsynthAlmLine2 Article |
| 1.3.6.1.4.1.20044.25.2.3.3.12.1 | Rowpm404AlmsynthAlmLine2Entry | not-accessible | current | Row definition for the pm404AlmsynthAlmLine2 table |
| 1.3.6.1.4.1.20044.25.2.3.3.12.1.1 | Columnpm404AlmsynthAlmLine2Index | read-only | current | Index definition for the pm404AlmsynthAlmLine2 table |
| 1.3.6.1.4.1.20044.25.2.3.3.12.1.2 | Columnpm404AlmLine2SfpAbsentPortn | read-only | current | Line 2 SFP Absent :This OID indicates that the SFP module is not present in the Line 2 port. <Help> This alarm indicates if the line 2 transceiver is present. … |
| 1.3.6.1.4.1.20044.25.2.3.3.12.1.3 | Columnpm404AlmLine2DdmAbsentPortn | read-only | current | DDM Supported On Line 2 SFP :This OID indicates that the Line 2 SFP module does not support the Digital Diagnostic Monitoring function <Help> This status indic… |
| 1.3.6.1.4.1.20044.25.2.3.3.12.1.5 | Columnpm404AlmLine2HwFailPortn | read-only | current | Line 2 HW Fail :This OID indicates a failure on Line 2 port, most probably caused by a HW issue. <Condtype> LINE2_HW_FAIL_A <Probcause> equipmentMalfunction (1… |
| 1.3.6.1.4.1.20044.25.2.3.3.12.1.6 | Columnpm404AlmLine2LsdPortn | read-only | current | Line 2 SFP Laser Shutdown :This OID indicates the Line 2 SFP transmitter output has shut down. <Help> This status indicates if the line 2 transceiver laser is … |
| 1.3.6.1.4.1.20044.25.2.3.3.12.1.7 | Columnpm404AlmLine2LocalOosPortn | read-only | current | Line 2 Port In Servicee :This OID indicates that the local Line 2 port is In Service (1) or Out of Service (2) <Help> This status indicates if the line port 2 … |
| 1.3.6.1.4.1.20044.25.2.3.3.12.1.9 | Columnpm404AlmLine2DwCaisPortn | read-only | current | Line 2 AIS Inserted :This OID indicates a CAIS has been inserted on the output Line 2 port. <Help> This status indicates if a Line Alarm Indication Signal is c… |
| 1.3.6.1.4.1.20044.25.2.3.3.12.1.10 | Columnpm404AlmLine2DdmWarningPortn | read-only | current | Warning On Line 2 SFP DDM :This OID indicates a warning is being received from the Line 2 SFP DDM <Help> This alarm indicates if a DDM Warning has been detecte… |
| 1.3.6.1.4.1.20044.25.2.3.3.12.1.11 | Columnpm404AlmLine2DdmAlmPortn | read-only | current | Alarm On Line 2 SFP DDM :This OID indicates an alarm is being received from the Line 2 SFP DDM <Help> This alarm indicates if a DDM Alarm has been detected on … |
| 1.3.6.1.4.1.20044.25.2.3.3.12.1.13 | Columnpm404AlmLine2FailPortn | read-only | current | Line 2 Access Fail :This OID indicates a failure on the Line 2 port <Condtype> LINE2_FAIL_A <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (1… |
| 1.3.6.1.4.1.20044.25.2.3.3.20 | Tablepm404Almline2AccessioAlmTable | not-accessible | current | List of pm404Almline2AccessioAlm Article |
| 1.3.6.1.4.1.20044.25.2.3.3.20.1 | Rowpm404Almline2AccessioAlmEntry | not-accessible | current | Row definition for the pm404Almline2AccessioAlm table |
| 1.3.6.1.4.1.20044.25.2.3.3.20.1.1 | Columnpm404Almline2AccessioAlmIndex | read-only | current | Index definition for the pm404Almline2AccessioAlm table |
| 1.3.6.1.4.1.20044.25.2.3.3.20.1.2 | Columnpm404AlmLine2LasFailPortn | read-only | current | Line 2 SFP Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the Line 2 port (this alarm reports the transmitter failure alarm … |
| 1.3.6.1.4.1.20044.25.2.3.3.20.1.5 | Columnpm404AlmLine2LosPortn | read-only | current | Loss Of Optical Signal On Line 2 :This OID indicates that no signal is present on the SFP of the Line 2 port <Help> This alarm indicates if an optical signal i… |
| 1.3.6.1.4.1.20044.25.2.3.3.20.1.7 | Columnpm404AlmLine2LosCdrPortn | read-only | current | Loss Of Signal On CDR On Line 2 : <Condtype> LINE2_LOS_CDR_A <Probcause> receiveFailure (41) <Alarmtype> equipmentAlarm (5) <Polarity> (2) |
| 1.3.6.1.4.1.20044.25.2.3.3.20.1.8 | Columnpm404AlmLine2ErrSigCdrPortn | read-only | current | Error Signal On CDR On Line 2 : <Condtype> LINE2__ERR_SIG_CDR_A <Probcause> receiveFailure (41) <Alarmtype> equipmentAlarm (5) <Polarity> (2) |
| 1.3.6.1.4.1.20044.25.3 | Nodepm404measures | |||
| 1.3.6.1.4.1.20044.25.3.1 | Nodepm404MesrOther | |||
| 1.3.6.1.4.1.20044.25.3.2 | Nodepm404MesrClient | |||
| 1.3.6.1.4.1.20044.25.3.2.16 | Tablepm404Mesrline1TemperatureTable | not-accessible | current | List of pm404Mesrline1Temperature Article |
| 1.3.6.1.4.1.20044.25.3.2.16.1 | Rowpm404Mesrline1TemperatureEntry | not-accessible | current | Row definition for the pm404Mesrline1Temperature table |
| 1.3.6.1.4.1.20044.25.3.2.16.1.1 | Columnpm404Mesrline1TemperatureIndex | read-only | current | Index definition for the pm404Mesrline1Temperature table |
| 1.3.6.1.4.1.20044.25.3.2.16.1.2 | Columnpm404Mesrline1TemperaturePortn | read-only | current | Line 1 SFP Temperature :This OID gives the temperature value of the SFP, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit = C) <H… |
| 1.3.6.1.4.1.20044.25.3.2.24 | Tablepm404Mesrline1VoltTable | not-accessible | current | List of pm404Mesrline1Volt Article |
| 1.3.6.1.4.1.20044.25.3.2.24.1 | Rowpm404Mesrline1VoltEntry | not-accessible | current | Row definition for the pm404Mesrline1Volt table |
| 1.3.6.1.4.1.20044.25.3.2.24.1.1 | Columnpm404Mesrline1VoltIndex | read-only | current | Index definition for the pm404Mesrline1Volt table |
| 1.3.6.1.4.1.20044.25.3.2.24.1.2 | Columnpm404Mesrline1VoltPortn | read-only | current | Line 1 SFP Power Supply :This OID gives the 3V3 voltage value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/100… |
| 1.3.6.1.4.1.20044.25.3.2.32 | Tablepm404Mesrline1TxBiasTable | not-accessible | current | List of pm404Mesrline1TxBias Article |
| 1.3.6.1.4.1.20044.25.3.2.32.1 | Rowpm404Mesrline1TxBiasEntry | not-accessible | current | Row definition for the pm404Mesrline1TxBias table |
| 1.3.6.1.4.1.20044.25.3.2.32.1.1 | Columnpm404Mesrline1TxBiasIndex | read-only | current | Index definition for the pm404Mesrline1TxBias table |
| 1.3.6.1.4.1.20044.25.3.2.32.1.2 | Columnpm404Mesrline1TxBiasPortn | read-only | current | Line 1 SFP Laser Bias :This OID gives the bias value of the SFP, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <Help> This meas… |
| 1.3.6.1.4.1.20044.25.3.2.40 | Tablepm404Mesrline1TxPowerTable | not-accessible | current | List of pm404Mesrline1TxPower Article |
| 1.3.6.1.4.1.20044.25.3.2.40.1 | Rowpm404Mesrline1TxPowerEntry | not-accessible | current | Row definition for the pm404Mesrline1TxPower table |
| 1.3.6.1.4.1.20044.25.3.2.40.1.1 | Columnpm404Mesrline1TxPowerIndex | read-only | current | Index definition for the pm404Mesrline1TxPower table |
| 1.3.6.1.4.1.20044.25.3.2.40.1.2 | Columnpm404Mesrline1TxPowerPortn | read-only | current | Line 1 SFP Tx Power :This OID gives the transmit power value of the SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm)… |
| 1.3.6.1.4.1.20044.25.3.2.48 | Tablepm404Mesrline1RxPowerTable | not-accessible | current | List of pm404Mesrline1RxPower Article |
| 1.3.6.1.4.1.20044.25.3.2.48.1 | Rowpm404Mesrline1RxPowerEntry | not-accessible | current | Row definition for the pm404Mesrline1RxPower table |
| 1.3.6.1.4.1.20044.25.3.2.48.1.1 | Columnpm404Mesrline1RxPowerIndex | read-only | current | Index definition for the pm404Mesrline1RxPower table |
| 1.3.6.1.4.1.20044.25.3.2.48.1.2 | Columnpm404Mesrline1RxPowerPortn | read-only | current | Line 1 SFP Rx Power :This OID gives the receive power value of the SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <H… |
| 1.3.6.1.4.1.20044.25.3.3 | Nodepm404MesrLine | |||
| 1.3.6.1.4.1.20044.25.3.3.20 | Tablepm404Mesrline2TemperatureTable | not-accessible | current | List of pm404Mesrline2Temperature Article |
| 1.3.6.1.4.1.20044.25.3.3.20.1 | Rowpm404Mesrline2TemperatureEntry | not-accessible | current | Row definition for the pm404Mesrline2Temperature table |
| 1.3.6.1.4.1.20044.25.3.3.20.1.1 | Columnpm404Mesrline2TemperatureIndex | read-only | current | Index definition for the pm404Mesrline2Temperature table |
| 1.3.6.1.4.1.20044.25.3.3.20.1.2 | Columnpm404Mesrline2TemperaturePortn | read-only | current | Line 2 SFP Temperature :This OID gives the temperature value of the SFP, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit = C) <H… |
| 1.3.6.1.4.1.20044.25.3.3.28 | Tablepm404Mesrline2VoltTable | not-accessible | current | List of pm404Mesrline2Volt Article |
| 1.3.6.1.4.1.20044.25.3.3.28.1 | Rowpm404Mesrline2VoltEntry | not-accessible | current | Row definition for the pm404Mesrline2Volt table |
| 1.3.6.1.4.1.20044.25.3.3.28.1.1 | Columnpm404Mesrline2VoltIndex | read-only | current | Index definition for the pm404Mesrline2Volt table |
| 1.3.6.1.4.1.20044.25.3.3.28.1.2 | Columnpm404Mesrline2VoltPortn | read-only | current | Line 2 SFP Power Supply :This OID gives the 3V3 voltage value of the SFP, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/10000) (Unit = V) <He… |
| 1.3.6.1.4.1.20044.25.3.3.36 | Tablepm404Mesrline2TxBiasTable | not-accessible | current | List of pm404Mesrline2TxBias Article |
| 1.3.6.1.4.1.20044.25.3.3.36.1 | Rowpm404Mesrline2TxBiasEntry | not-accessible | current | Row definition for the pm404Mesrline2TxBias table |
| 1.3.6.1.4.1.20044.25.3.3.36.1.1 | Columnpm404Mesrline2TxBiasIndex | read-only | current | Index definition for the pm404Mesrline2TxBias table |
| 1.3.6.1.4.1.20044.25.3.3.36.1.2 | Columnpm404Mesrline2TxBiasPortn | read-only | current | Line 2 SFP Laser Bias :This OID gives the bias value of the SFP, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <Help> This meas… |
| 1.3.6.1.4.1.20044.25.3.3.44 | Tablepm404Mesrline2TxPowerTable | not-accessible | current | List of pm404Mesrline2TxPower Article |
| 1.3.6.1.4.1.20044.25.3.3.44.1 | Rowpm404Mesrline2TxPowerEntry | not-accessible | current | Row definition for the pm404Mesrline2TxPower table |
| 1.3.6.1.4.1.20044.25.3.3.44.1.1 | Columnpm404Mesrline2TxPowerIndex | read-only | current | Index definition for the pm404Mesrline2TxPower table |
| 1.3.6.1.4.1.20044.25.3.3.44.1.2 | Columnpm404Mesrline2TxPowerPortn | read-only | current | Line 2 SFP Tx Power :This OID gives the transmit power value of the SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm)… |
| 1.3.6.1.4.1.20044.25.3.3.52 | Tablepm404Mesrline2RxPowerTable | not-accessible | current | List of pm404Mesrline2RxPower Article |
| 1.3.6.1.4.1.20044.25.3.3.52.1 | Rowpm404Mesrline2RxPowerEntry | not-accessible | current | Row definition for the pm404Mesrline2RxPower table |
| 1.3.6.1.4.1.20044.25.3.3.52.1.1 | Columnpm404Mesrline2RxPowerIndex | read-only | current | Index definition for the pm404Mesrline2RxPower table |
| 1.3.6.1.4.1.20044.25.3.3.52.1.2 | Columnpm404Mesrline2RxPowerPortn | read-only | current | Line 2 SFP Rx Power :This OID gives the receive power value of the SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <H… |
| 1.3.6.1.4.1.20044.25.4 | Nodepm404counters | |||
| 1.3.6.1.4.1.20044.25.4.1 | Nodepm404CntOther | |||
| 1.3.6.1.4.1.20044.25.4.2 | Nodepm404CntClient | |||
| 1.3.6.1.4.1.20044.25.4.3 | Nodepm404CntLine | |||
| 1.3.6.1.4.1.20044.25.6 | Nodepm404controlsWrite | |||
| 1.3.6.1.4.1.20044.25.6.1 | Nodepm404CtrlOther | |||
| 1.3.6.1.4.1.20044.25.6.1.0 | Nodepm404Ctrlsynth0 | |||
| 1.3.6.1.4.1.20044.25.6.1.0.1 | Scalarpm404CtrlConfLoad | read-write | current | Load Configuration Tables :When set this enables loading from flash configuration1 into the module. |
| 1.3.6.1.4.1.20044.25.6.1.0.9 | Scalarpm404CtrlConfFlash | read-write | current | Write Configuration Tables :This bit saves the current configuration of the module as configuration in the flash. <Help> This control saves the customer config… |
| 1.3.6.1.4.1.20044.25.6.1.0.13 | Scalarpm404CtrlConfClear | read-write | current | Clear Configuration Tables :This bit clears the configuration tables from configuration in the flash. <Help> This control restores the default configuration of… |
| 1.3.6.1.4.1.20044.25.6.1.4 | Nodepm404Ctrlsynth4 | |||
| 1.3.6.1.4.1.20044.25.6.1.4.1 | Scalarpm404CtrlCorrelatOn | read-write | current | Enable Alarm Correlation :This OID enables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.25.6.1.4.2 | Scalarpm404CtrlCorrelatOff | read-write | current | Disable Alarm Correlation :This OID disables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.25.6.1.5 | Nodepm404CtrlswMgnt | |||
| 1.3.6.1.4.1.20044.25.6.1.5.2 | Scalarpm404CtrlColdReset | read-write | current | PM Cold Reset :This OID, when set, causes a cold reset of the Software. This reset is traffic affecting, and the configuration of Software is reloaded on start… |
| 1.3.6.1.4.1.20044.25.6.1.5.3 | Scalarpm404CtrlWarmReset | read-write | current | PM Warm Reset :This OID, when set, causes a warm reset of the Software. This reset is not traffic affecting, and the configuration of the Sofwtare remains unch… |
| 1.3.6.1.4.1.20044.25.6.1.72 | Nodepm404CtrlledTest | |||
| 1.3.6.1.4.1.20044.25.6.1.72.1 | Scalarpm404CtrlGreenLed | read-write | current | Green Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green |
| 1.3.6.1.4.1.20044.25.6.1.72.2 | Scalarpm404CtrlRedLed | read-write | current | Red Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red |
| 1.3.6.1.4.1.20044.25.6.1.72.3 | Scalarpm404CtrlLedOff | read-write | current | Leds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF |
| 1.3.6.1.4.1.20044.25.6.1.73 | Nodepm404CtrlmoduleOosMode | |||
| 1.3.6.1.4.1.20044.25.6.1.73.1 | Scalarpm404CtrlModuleOosMode | read-write | current | PM Out Of Service :This OID sets the PM Out Of Service <Help> This control defines the service state of the complete module |
| 1.3.6.1.4.1.20044.25.6.2 | Nodepm404CtrlClient | |||
| 1.3.6.1.4.1.20044.25.6.2.16 | Tablepm404Ctrlline1SfpOnoffTable | not-accessible | current | List of pm404Ctrlline1SfpOnoff Article |
| 1.3.6.1.4.1.20044.25.6.2.16.1 | Rowpm404Ctrlline1SfpOnoffEntry | not-accessible | current | Row definition for the pm404Ctrlline1SfpOnoff table |
| 1.3.6.1.4.1.20044.25.6.2.16.1.1 | Columnpm404Ctrlline1SfpOnoffIndex | read-only | current | Index definition for the pm404Ctrlline1SfpOnoff table |
| 1.3.6.1.4.1.20044.25.6.2.16.1.2 | Columnpm404Ctrlline1SfpOnoffPortn | read-write | current | Line 1 SFP Laser Shutdown :This OID switches off the SFP <Help> This control defines the laser state of the line 1 transceiver |
| 1.3.6.1.4.1.20044.25.6.2.17 | Tablepm404Ctrlline1LoopbackTable | not-accessible | current | List of pm404Ctrlline1Loopback Article |
| 1.3.6.1.4.1.20044.25.6.2.17.1 | Rowpm404Ctrlline1LoopbackEntry | not-accessible | current | Row definition for the pm404Ctrlline1Loopback table |
| 1.3.6.1.4.1.20044.25.6.2.17.1.1 | Columnpm404Ctrlline1LoopbackIndex | read-only | current | Index definition for the pm404Ctrlline1Loopback table |
| 1.3.6.1.4.1.20044.25.6.2.17.1.2 | Columnpm404Ctrlline1LoopbackPortn | read-write | current | Line 1 Facility Loopback :This OID operates a Client Facility Loopback, looping client input signal on the client output port. The loop is located on the clien… |
| 1.3.6.1.4.1.20044.25.6.2.18 | Tablepm404Ctrlline1LoopbackTermTable | not-accessible | current | List of pm404Ctrlline1LoopbackTerm Article |
| 1.3.6.1.4.1.20044.25.6.2.18.1 | Rowpm404Ctrlline1LoopbackTermEntry | not-accessible | current | Row definition for the pm404Ctrlline1LoopbackTerm table |
| 1.3.6.1.4.1.20044.25.6.2.18.1.1 | Columnpm404Ctrlline1LoopbackTermIndex | read-only | current | Index definition for the pm404Ctrlline1LoopbackTerm table |
| 1.3.6.1.4.1.20044.25.6.2.18.1.2 | Columnpm404Ctrlline1LoopbackTermPortn | read-write | current | Line 1 Terminal Loopback :This OID operates a Client Terminal Loopback, looping client input signal on the client output port. The loop is located on the line … |
| 1.3.6.1.4.1.20044.25.6.2.20 | Tablepm404Ctrlline1OosModeTable | not-accessible | current | List of pm404Ctrlline1OosMode Article |
| 1.3.6.1.4.1.20044.25.6.2.20.1 | Rowpm404Ctrlline1OosModeEntry | not-accessible | current | Row definition for the pm404Ctrlline1OosMode table |
| 1.3.6.1.4.1.20044.25.6.2.20.1.1 | Columnpm404Ctrlline1OosModeIndex | read-only | current | Index definition for the pm404Ctrlline1OosMode table |
| 1.3.6.1.4.1.20044.25.6.2.20.1.2 | Columnpm404Ctrlline1OosModePortn | read-write | current | Line 1 Port Out Of Service :This OID sets the port Out Of Service <Help> This controls defines the service state of the line 1 port |
| 1.3.6.1.4.1.20044.25.6.2.48 | Tablepm404CtrlprotocolTable | not-accessible | current | List of pm404Ctrlprotocol Article |
| 1.3.6.1.4.1.20044.25.6.2.48.1 | Rowpm404CtrlprotocolEntry | not-accessible | current | Row definition for the pm404Ctrlprotocol table |
| 1.3.6.1.4.1.20044.25.6.2.48.1.1 | Columnpm404CtrlprotocolIndex | read-only | current | Index definition for the pm404Ctrlprotocol table |
| 1.3.6.1.4.1.20044.25.6.2.48.1.2 | Columnpm404CtrlprotocolPortn | read-write | current | Lines Bitrate: This OID sets the protocol of the lines port. |
| 1.3.6.1.4.1.20044.25.6.3 | Nodepm404CtrlLine | |||
| 1.3.6.1.4.1.20044.25.6.3.64 | Tablepm404Ctrlline2SfpOnoffTable | not-accessible | current | List of pm404Ctrlline2SfpOnoff Article |
| 1.3.6.1.4.1.20044.25.6.3.64.1 | Rowpm404Ctrlline2SfpOnoffEntry | not-accessible | current | Row definition for the pm404Ctrlline2SfpOnoff table |
| 1.3.6.1.4.1.20044.25.6.3.64.1.1 | Columnpm404Ctrlline2SfpOnoffIndex | read-only | current | Index definition for the pm404Ctrlline2SfpOnoff table |
| 1.3.6.1.4.1.20044.25.6.3.64.1.2 | Columnpm404Ctrlline2SfpOnoffPortn | read-write | current | Line 2 SFP Laser Shutdown :This OID switches off the SFP <Help> This control defines the laser state of the line 2 transceiver |
| 1.3.6.1.4.1.20044.25.6.3.65 | Tablepm404Ctrlline2OosModeTable | not-accessible | current | List of pm404Ctrlline2OosMode Article |
| 1.3.6.1.4.1.20044.25.6.3.65.1 | Rowpm404Ctrlline2OosModeEntry | not-accessible | current | Row definition for the pm404Ctrlline2OosMode table |
| 1.3.6.1.4.1.20044.25.6.3.65.1.1 | Columnpm404Ctrlline2OosModeIndex | read-only | current | Index definition for the pm404Ctrlline2OosMode table |
| 1.3.6.1.4.1.20044.25.6.3.65.1.2 | Columnpm404Ctrlline2OosModePortn | read-write | current | Line 2 Port Out Of Service :This OID sets the port Out Of Service <Help> This controls defines the service state of the line 2 port |
| 1.3.6.1.4.1.20044.25.6.3.66 | Tablepm404Ctrlline2LoopbackTable | not-accessible | current | List of pm404Ctrlline2Loopback Article |
| 1.3.6.1.4.1.20044.25.6.3.66.1 | Rowpm404Ctrlline2LoopbackEntry | not-accessible | current | Row definition for the pm404Ctrlline2Loopback table |
| 1.3.6.1.4.1.20044.25.6.3.66.1.1 | Columnpm404Ctrlline2LoopbackIndex | read-only | current | Index definition for the pm404Ctrlline2Loopback table |
| 1.3.6.1.4.1.20044.25.6.3.66.1.2 | Columnpm404Ctrlline2LoopbackPortn | read-write | current | Line 2 Facility Loopback :This OID operates a Line Facility Loopback, looping line input signal on the line output port. The loop is located on the line transc… |
| 1.3.6.1.4.1.20044.25.6.3.67 | Tablepm404Ctrlline2LoopbackTermTable | not-accessible | current | List of pm404Ctrlline2LoopbackTerm Article |
| 1.3.6.1.4.1.20044.25.6.3.67.1 | Rowpm404Ctrlline2LoopbackTermEntry | not-accessible | current | Row definition for the pm404Ctrlline2LoopbackTerm table |
| 1.3.6.1.4.1.20044.25.6.3.67.1.1 | Columnpm404Ctrlline2LoopbackTermIndex | read-only | current | Index definition for the pm404Ctrlline2LoopbackTerm table |
| 1.3.6.1.4.1.20044.25.6.3.67.1.2 | Columnpm404Ctrlline2LoopbackTermPortn | read-write | current | Line 2 Terminal Loopback :This OID operates a Line Terminal Loopback, looping line input signal on the line output port. The loop is located on all client tran… |
| 1.3.6.1.4.1.20044.25.7 | Nodepm404ri | |||
| 1.3.6.1.4.1.20044.25.7.1 | Nodepm404riTable | |||
| 1.3.6.1.4.1.20044.25.7.1.1 | Tablepm404RinvLine1Table | not-accessible | current | List of the SFPs on the selected module |
| 1.3.6.1.4.1.20044.25.7.1.1.1 | Rowpm404RinvLine1Entry | not-accessible | current | Row definition for the Line1 SFP table |
| 1.3.6.1.4.1.20044.25.7.1.1.1.1 | Columnpm404RinvLine1Index | read-only | current | Index for Line1 SFP table |
| 1.3.6.1.4.1.20044.25.7.1.1.1.2 | Columnpm404RinvSfpLine1 | read-only | current | Inventory for the SFP: This OID contains the inventory for the Line1 SFP |
| 1.3.6.1.4.1.20044.25.7.1.2 | Tablepm404RinvLine2Table | not-accessible | current | List of the SFPs on the selected module |
| 1.3.6.1.4.1.20044.25.7.1.2.1 | Rowpm404RinvLine2Entry | not-accessible | current | Row definition for the Line SFP table |
| 1.3.6.1.4.1.20044.25.7.1.2.1.1 | Columnpm404RinvLine2Index | read-only | current | Index for SFP table |
| 1.3.6.1.4.1.20044.25.7.1.2.1.2 | Columnpm404RinvsfpLine2 | read-only | current | Inventory for the SFP: This OID contains the inventory for the Line2 SFP |
| 1.3.6.1.4.1.20044.25.7.2 | Scalarpm404RinvReloadInventory | read-write | current | Reload the inventory: This OID triggers an inventory reload. |
| 1.3.6.1.4.1.20044.25.7.3 | Scalarpm404RinvHwPlatform | read-only | current | HW platform description: This OID contains the description of the Hardware platform. |
| 1.3.6.1.4.1.20044.25.7.4 | Scalarpm404RinvModulePlatform | read-only | current | Module platform description: This OID contains the description of the Module. |
| 1.3.6.1.4.1.20044.25.7.5 | Scalarpm404RinvSwPlatform | read-only | current | SW platform description: This OID contains the description of the Software platform. |
| 1.3.6.1.4.1.20044.25.7.6 | Scalarpm404RinvGwPlatform | read-only | current | GW platform desciption: This OID contains the description of the Gateware platform. |
| 1.3.6.1.4.1.20044.25.9 | Nodepm404Config | |||
| 1.3.6.1.4.1.20044.25.9.1 | Nodepm404CfgLsd | |||
| 1.3.6.1.4.1.20044.25.9.1.1 | Tablepm404CfgLine1LsdTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.25.9.1.1.1 | Rowpm404CfgLine1LsdEntry | not-accessible | current | Row definition for the lsd table |
| 1.3.6.1.4.1.20044.25.9.1.1.1.1 | Columnpm404CfgLine1LsdIndex | read-only | current | Index definition for the line1Lsd table |
| 1.3.6.1.4.1.20044.25.9.1.1.1.3 | Columnpm404CfgLine1LsdModePortn | read-write | current | CAIS mode on Lines Port :This register selects the way to activate the laser upon CAIS/CSF criteria detection on Port |
| 1.3.6.1.4.1.20044.25.9.1.1.1.4 | Columnpm404CfgLine1AccessioCtrbInsPortn | read-write | current | CAIS contributors on Line 1 Port :This register selects the contributors to upstream CAIS/CSF on Port |
| 1.3.6.1.4.1.20044.25.9.1.1.1.7 | Columnpm404CfgLine2AccessioCtrbInsPortn | read-write | current | CAIS contributors on Lne 2 Port :This register selects the contributors to downstream CAIS/CSF on Port |
| 1.3.6.1.4.1.20044.25.9.2 | Nodepm404CfgStartUp | |||
| 1.3.6.1.4.1.20044.25.9.2.1 | Tablepm404CfgLine1StartupTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.25.9.2.1.1 | Rowpm404CfgLine1StartupEntry | not-accessible | current | Row definition for the startUp table |
| 1.3.6.1.4.1.20044.25.9.2.1.1.1 | Columnpm404CfgLine1StartupIndex | read-only | current | Index definition for the line1Startup table |
| 1.3.6.1.4.1.20044.25.9.2.1.1.3 | Columnpm404CfgLine1TrscvCtrlPortn | read-write | current | Default Settings on Line 1 TRSCV :This register configures the default initialisation settings on client transceiver. |
| 1.3.6.1.4.1.20044.25.9.2.1.1.4 | Columnpm404CfgLine1ProtocolPortn | read-write | current | Default Protocol on Line 1 :This register configures the default initialisation protocol on the port. |
| 1.3.6.1.4.1.20044.25.9.2.1.1.5 | Columnpm404CfgLine1OosModePortn | read-write | current | Default Settings on Line 1 TRSCV :This register configures the default initialisation settings on client transceiver. |
| 1.3.6.1.4.1.20044.25.9.2.2 | Tablepm404CfgLine2StartupTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.25.9.2.2.1 | Rowpm404CfgLine2StartupEntry | not-accessible | current | Row definition for the startUp table |
| 1.3.6.1.4.1.20044.25.9.2.2.1.1 | Columnpm404CfgLine2StartupIndex | read-only | current | Index definition for the line2Startup table |
| 1.3.6.1.4.1.20044.25.9.2.2.1.3 | Columnpm404CfgLine2TrscvCtrlPortn | read-write | current | Default Settings on Line 2 TRSCV :This register configures the default initialisation settings on line transceiver. |
| 1.3.6.1.4.1.20044.25.9.2.2.1.4 | Columnpm404CfgLine2OosModePortn | read-write | current | Default Settings on Line 2 TRSCV :This register configures the default initialisation settings on line transceiver. |
| 1.3.6.1.4.1.20044.25.9.3 | Nodepm404CfgLabels | |||
| 1.3.6.1.4.1.20044.25.9.3.1 | Tablepm404CfgLabelclientTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.25.9.3.1.1 | Rowpm404CfgLabelclientEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.25.9.3.1.1.1 | Columnpm404CfgLabelclientIndex | read-only | current | Index definition for the labelclient table |
| 1.3.6.1.4.1.20044.25.9.3.1.1.3 | Columnpm404CfgLabelclientPortn | read-write | current | Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. |
| 1.3.6.1.4.1.20044.25.9.3.2 | Tablepm404CfgLabellineTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.25.9.3.2.1 | Rowpm404CfgLabellineEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.25.9.3.2.1.1 | Columnpm404CfgLabellineIndex | read-only | current | Index definition for the labelline table |
| 1.3.6.1.4.1.20044.25.9.3.2.1.3 | Columnpm404CfgLabellinePortn | read-write | current | Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. |
| 1.3.6.1.4.1.20044.25.9.257 | Scalarpm404CfgWriteConfiguration | read-write | current | Write configuration to module:This OID writes the complete configuration to the module |
| 1.3.6.1.4.1.20044.25.10 | Nodepm404traps | |||
| 1.3.6.1.4.1.20044.25.10.2 | Scalarpm404trapPortNumber | read-only | current | Last port which generates a trap |
| 1.3.6.1.4.1.20044.25.10.3 | Scalarpm404trapLineNumber | read-only | current | Last Line which generates a trap |
| 1.3.6.1.4.1.20044.25.10.4 | Scalarpm404trapBoardNumber | read-only | current | Last module which generates a trap |
| 1.3.6.1.4.1.20044.25.10.30 | Notificationpm404Line2TrapNotUrgentGoesOn | current | Not urgent Line default is activated | |
| 1.3.6.1.4.1.20044.25.10.31 | Notificationpm404Line2TrapNotUrgentGoesOff | current | Not urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.25.10.32 | Notificationpm404Line2TrapUrgentGoesOn | current | Urgent Line default is activated | |
| 1.3.6.1.4.1.20044.25.10.33 | Notificationpm404Line2TrapUrgentGoesOff | current | Urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.25.10.34 | Notificationpm404Line2TrapCritGoesOn | current | Critical Line default is activated | |
| 1.3.6.1.4.1.20044.25.10.35 | Notificationpm404Line2TrapCritGoesOff | current | Critical Line default disappeared | |
| 1.3.6.1.4.1.20044.25.10.40 | Notificationpm404Line1TrapNotUrgentGoesOn | current | Not urgent client default is activated | |
| 1.3.6.1.4.1.20044.25.10.41 | Notificationpm404Line1TrapNotUrgentGoesOff | current | Not urgent client default disappeared | |
| 1.3.6.1.4.1.20044.25.10.42 | Notificationpm404Line1TrapUrgentGoesOn | current | Urgent client default is activated | |
| 1.3.6.1.4.1.20044.25.10.43 | Notificationpm404Line1TrapUrgentGoesOff | current | Urgent client default disappeared | |
| 1.3.6.1.4.1.20044.25.10.44 | Notificationpm404Line1TrapCritGoesOn | current | Critical client default is activated | |
| 1.3.6.1.4.1.20044.25.10.45 | Notificationpm404Line1TrapCritGoesOff | current | Critical client default disappeared | |
| 1.3.6.1.4.1.20044.25.10.50 | Notificationpm404PowerTrapUrgentGoesOn | current | Urgent power supply default is activated | |
| 1.3.6.1.4.1.20044.25.10.51 | Notificationpm404PowerTrapUrgentGoesOff | current | Urgent power supply default disappeared |