EKINOPS-Pm600frs06-MIB
937 objects
Creation.
Imported Objects
| EKINOPS-MIB | EkiApiState EkiMeasureType EkiMode ekinops EkiOnOff EkiProtocol EkiState EkiSynchroMode |
| SNMPv2-SMI | Counter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20044.115 | IdentitymodulePm600frs06 | Creation. | ||
| 1.3.6.1.4.1.20044.115.2 | Nodepm600frs06alarms | |||
| 1.3.6.1.4.1.20044.115.2.1 | Nodepm600frs06AlmOther | |||
| 1.3.6.1.4.1.20044.115.2.1.1 | Nodepm600frs06AlmOtherNurg | |||
| 1.3.6.1.4.1.20044.115.2.1.1.2 | Nodepm600frs06AlmsynthAlm2 | |||
| 1.3.6.1.4.1.20044.115.2.1.1.2.1 | Scalarpm600frs06AlmConfTableSave | read-only | current | PM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> infor… |
| 1.3.6.1.4.1.20044.115.2.1.1.2.2 | Scalarpm600frs06AlmInvUpload | read-only | current | Inventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> informationalStatus(1000) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.115.2.1.1.2.3 | Scalarpm600frs06AlmConfTableLoad | read-only | current | PM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> informationalStat… |
| 1.3.6.1.4.1.20044.115.2.1.1.2.4 | Scalarpm600frs06AlmCorrelatOff | read-only | current | Not Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> informationalStatus(1000) <Alarmtype… |
| 1.3.6.1.4.1.20044.115.2.1.1.2.5 | Scalarpm600frs06AlmMaintenanceOn | read-only | current | Maintenance Mode :This OID indicates that the RM is in maintenance mode. <Help> This alarm indicates that the maintenance mode is enabled on the PM <Condtype> … |
| 1.3.6.1.4.1.20044.115.2.1.2 | Nodepm600frs06AlmOtherUrg | |||
| 1.3.6.1.4.1.20044.115.2.1.2.336 | Nodepm600frs06AlmmodFanFail | |||
| 1.3.6.1.4.1.20044.115.2.1.2.336.1 | Scalarpm600frs06AlmFanFail | read-only | current | Fan Module Failure :This OID indicates that the FAN unit inside the module is in fail condition <Help> This alarm indicates that the FAN is in a fail condition… |
| 1.3.6.1.4.1.20044.115.2.1.2.336.2 | Scalarpm600frs06AlmFanHighSpeed | read-only | current | Fan High Speed :This OID indicates the fan is blowing at high speed <Help> This alarm indicates the fan is blowing at high speed <Condtype> FAN_HIGH_SPEED <Pro… |
| 1.3.6.1.4.1.20044.115.2.1.3 | Nodepm600frs06AlmOtherCrit | |||
| 1.3.6.1.4.1.20044.115.2.1.3.0 | Nodepm600frs06AlmsynthAlm0 | |||
| 1.3.6.1.4.1.20044.115.2.1.3.0.2 | Scalarpm600frs06AlmFailFan | read-only | current | Fan Fail :This OID is at 1 when any fail occurs on the fan tray <Help> This alarm indicates that the Fan tray module is in a failure condition <Condtype> FAIL_… |
| 1.3.6.1.4.1.20044.115.2.1.3.0.9 | Scalarpm600frs06AlmModGlobFail | read-only | current | Module Failure :This OID is set on detection of a failure originating from the RM <Help> This alarm is set on detection of a failure originating from the equip… |
| 1.3.6.1.4.1.20044.115.2.1.3.0.15 | Scalarpm600frs06AlmDefFuseA | read-only | current | Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.115.2.1.3.0.16 | Scalarpm600frs06AlmDefFuseB | read-only | current | Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.115.2.1.3.78 | Nodepm600frs06AlmmsaModuleState | |||
| 1.3.6.1.4.1.20044.115.2.1.3.78.1 | Scalarpm600frs06AlmMsaInitialize | read-only | current | Line Trscv Initialize :This OID indicates the Line Trscv initialization is in progress <Help> Status indicating the Line Trscv initialization is in progress <C… |
| 1.3.6.1.4.1.20044.115.2.1.3.78.2 | Scalarpm600frs06AlmMsaLowPower | read-only | current | Line Trscv Low Power :This OID indicates the Line Trscv is in low power state <Help> Status indicating the Line Trscv is in low power state <Condtype> MSA_LOW_… |
| 1.3.6.1.4.1.20044.115.2.1.3.78.3 | Scalarpm600frs06AlmMsaHighPowerUp | read-only | current | Line Trscv High Power Up :This OID indicates the Line Trscv is leaving Low Power state <Help> Status indicating the Line Trscv is leaving Low Power state <Cond… |
| 1.3.6.1.4.1.20044.115.2.1.3.78.4 | Scalarpm600frs06AlmMsaTxOff | read-only | current | Line Trscv Laser Shutdown :This OID indicates the Line Trscv Laser is OFF <Help> Status indicating the Line Trscv Laser is OFF <Condtype> MSA_TX_OFF <Probcause… |
| 1.3.6.1.4.1.20044.115.2.1.3.78.5 | Scalarpm600frs06AlmMsaTxTurnOn | read-only | current | Line Trscv Laser Turn On :This OID indicates the Line Trscv is turning on its laser <Help> Status indicating the Line Trscv is turning on its laser <Condtype> … |
| 1.3.6.1.4.1.20044.115.2.1.3.78.6 | Scalarpm600frs06AlmMsaReady | read-only | current | Line Trscv Ready :This OID indicates the Line Trscv is ready to operate <Help> Status indicating the Line Trscv is ready to operate <Condtype> MSA_READY <Probc… |
| 1.3.6.1.4.1.20044.115.2.1.3.78.7 | Scalarpm600frs06AlmMsaFault | read-only | current | Line Trscv Fault :This OID indicates the Line Trscv is in Fault state <Help> Status indicating the Line Trscv is in Fault state <Condtype> MSA_FAULT <Probcause… |
| 1.3.6.1.4.1.20044.115.2.1.3.78.8 | Scalarpm600frs06AlmMsaTxTurnOff | read-only | current | Line Trscv Laser Turn Off :This OID indicates the Line Trscv is turning off its laser <Help> Status indicating the Line Trscv is turning off its laser <Condtyp… |
| 1.3.6.1.4.1.20044.115.2.1.3.78.9 | Scalarpm600frs06AlmMsaHighPowerDown | read-only | current | Line Trscv High Power Down :This OID indicates the Line Trscv is entering Low Power state <Help> Status indicating the Line Trscv is entering Low Power state <… |
| 1.3.6.1.4.1.20044.115.2.1.3.78.12 | Scalarpm600frs06AlmModesNotSupported | read-only | current | Module Mode Not Supported :This OID indicates the configured Module Mode is not supported on the module<Help> This alarm indicates the configured Module Mode i… |
| 1.3.6.1.4.1.20044.115.2.1.3.78.13 | Scalarpm600frs06AlmMsaTempShutdown | read-only | current | Line Trscv Temperature Shutdown :This OID indicates a Trscv shutdown caused by a temperature is out of range<Help> Alarm indicating a Trscv temperature shutdow… |
| 1.3.6.1.4.1.20044.115.2.1.3.78.14 | Scalarpm600frs06AlmMsaTempWarning | read-only | current | Line Trscv Temperature Warning :This OID indicates a Trscv warning caused by a temperature is out of range<Help> Warning indicating a Trscv temperature out of … |
| 1.3.6.1.4.1.20044.115.2.1.3.78.15 | Scalarpm600frs06AlmMsaTempAlarm | read-only | current | Line Trscv Temperature Alarm :This OID indicates a Trscv alarm caused by a temperature is out of range<Help> Alarm indicating a Trscv temperature out of range … |
| 1.3.6.1.4.1.20044.115.2.1.3.78.16 | Scalarpm600frs06AlmCoolingSystemAbsent | read-only | current | Air Flow Module Absent :This OID indicates a cooling system not present as recommended by the rules<Help> Alarm indicating a cooling system not present as reco… |
| 1.3.6.1.4.1.20044.115.2.2 | Nodepm600frs06AlmClient | |||
| 1.3.6.1.4.1.20044.115.2.2.1 | Nodepm600frs06AlmClientNurg | |||
| 1.3.6.1.4.1.20044.115.2.2.1.272 | Tablepm600frs06AlmclientSfpWarnDdmTable | not-accessible | current | List of pm600frs06AlmclientSfpWarnDdm Article |
| 1.3.6.1.4.1.20044.115.2.2.1.272.1 | Rowpm600frs06AlmclientSfpWarnDdmEntry | not-accessible | current | Row definition for the pm600frs06AlmclientSfpWarnDdm table |
| 1.3.6.1.4.1.20044.115.2.2.1.272.1.1 | Columnpm600frs06AlmclientSfpWarnDdmIndex | read-only | current | Index definition for the pm600frs06AlmclientSfpWarnDdm table |
| 1.3.6.1.4.1.20044.115.2.2.1.272.1.2 | Columnpm600frs06AlmTxPwLowWngPortn | read-only | current | Client Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning … |
| 1.3.6.1.4.1.20044.115.2.2.1.272.1.3 | Columnpm600frs06AlmTxPwrHighWngPortn | read-only | current | Client Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warnin… |
| 1.3.6.1.4.1.20044.115.2.2.1.272.1.4 | Columnpm600frs06AlmTxBiasLowWngPortn | read-only | current | Client Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warnin… |
| 1.3.6.1.4.1.20044.115.2.2.1.272.1.5 | Columnpm600frs06AlmTxBiasHighWngPortn | read-only | current | Client Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warn… |
| 1.3.6.1.4.1.20044.115.2.2.1.272.1.6 | Columnpm600frs06AlmVccLowWngPortn | read-only | current | Client Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM <He… |
| 1.3.6.1.4.1.20044.115.2.2.1.272.1.7 | Columnpm600frs06AlmVccHighWngPortn | read-only | current | Client Trscv Power Supply High Warning :This OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM <… |
| 1.3.6.1.4.1.20044.115.2.2.1.272.1.8 | Columnpm600frs06AlmTempLowWngPortn | read-only | current | Client Trscv Temp Low Warning :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM <Help> Warni… |
| 1.3.6.1.4.1.20044.115.2.2.1.272.1.9 | Columnpm600frs06AlmTempHighWngPortn | read-only | current | Client Trscv Temp High Warning :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM <Help> War… |
| 1.3.6.1.4.1.20044.115.2.2.1.272.1.16 | Columnpm600frs06AlmRxPwrLowWngPortn | read-only | current | Client Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning i… |
| 1.3.6.1.4.1.20044.115.2.2.1.272.1.17 | Columnpm600frs06AlmRxPwrHighWngPortn | read-only | current | Client Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning… |
| 1.3.6.1.4.1.20044.115.2.2.2 | Nodepm600frs06AlmClientUrg | |||
| 1.3.6.1.4.1.20044.115.2.2.2.152 | Tablepm600frs06AlmclientHostLaneFaultTable | not-accessible | current | List of pm600frs06AlmclientHostLaneFault Article |
| 1.3.6.1.4.1.20044.115.2.2.2.152.1 | Rowpm600frs06AlmclientHostLaneFaultEntry | not-accessible | current | Row definition for the pm600frs06AlmclientHostLaneFault table |
| 1.3.6.1.4.1.20044.115.2.2.2.152.1.1 | Columnpm600frs06AlmclientHostLaneFaultIndex | read-only | current | Index definition for the pm600frs06AlmclientHostLaneFault table |
| 1.3.6.1.4.1.20044.115.2.2.2.152.1.2 | Columnpm600frs06AlmClientLossOfSyncPortn | read-only | current | Client Frame Alignment Loss :This OID indicates the module is not aligned with the incoming Client signal <Help> Alarm indicating the module is not aligned wit… |
| 1.3.6.1.4.1.20044.115.2.2.2.152.1.3 | Columnpm600frs06AlmClientInputLossOfSigPortn | read-only | current | Client Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Client Trscv <Help> Alarm indicating a Loss of Signal is detected on the Cl… |
| 1.3.6.1.4.1.20044.115.2.2.2.152.1.4 | Columnpm600frs06AlmClientLanesMarkerUnlockPortn | read-only | current | Client Lanes Marker Unlock :This OID indicates the Client lanes marker alignment is not lock <Help> Alarm indicating the Client lanes marker alignment is not l… |
| 1.3.6.1.4.1.20044.115.2.2.2.152.1.5 | Columnpm600frs06AlmClientLanes6466UnlockPortn | read-only | current | Client Lanes 64/66b Unlock :This OID indicates the Client 64/66b decoder is not lock <Help> Alarm indicating the Client 64/66b decoder is not lock <Condtype> C… |
| 1.3.6.1.4.1.20044.115.2.2.2.152.1.6 | Columnpm600frs06AlmClientLanesNotAlignedPortn | read-only | current | Client Lanes Not Aligned :This OID indicates the Client lanes are not aligned <Help> Alarm indicating the Client lanes are not aligned <Condtype> CLIENT_LANES_… |
| 1.3.6.1.4.1.20044.115.2.2.2.152.1.7 | Columnpm600frs06AlmClientCsfDetectedPortn | read-only | current | Client Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client… |
| 1.3.6.1.4.1.20044.115.2.2.2.152.1.10 | Columnpm600frs06AlmClientTxHostLolPortn | read-only | current | Client Host Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Client Trscv Host Lane <Help> Alarm indicating a Tx Loss of Lock on the Client Tr… |
| 1.3.6.1.4.1.20044.115.2.2.2.152.1.11 | Columnpm600frs06AlmClientLaneTxFifoErrorPortn | read-only | current | Client Host Lane Tx FIFO Error :This OID indicates a Tx FIFO Error on the Client Trscv Host Lane <Help> Alarm indicating a Tx FIFO Error on the Client Trscv Ho… |
| 1.3.6.1.4.1.20044.115.2.2.2.152.1.15 | Columnpm600frs06AlmClientBistErrorResultsPortn | read-only | current | BIST Error Results :This OID indicates the Built In Self Test result <Help> This alarm indicates the Built In Self Test result <Condtype> CLIENT_BIST_ERROR_RES… |
| 1.3.6.1.4.1.20044.115.2.2.2.152.1.16 | Columnpm600frs06AlmClientBistAlarmResultsPortn | read-only | current | BIST Alarm Results :This OID indicates the Built In Self Test result <Help> This alarm indicates the Built In Self Test result <Condtype> CLIENT_BIST_ALARM_RES… |
| 1.3.6.1.4.1.20044.115.2.2.2.152.1.17 | Columnpm600frs06AlmClientBistModePortn | read-only | current | BIST Mode :This OID indicates the Built In Self Test mode is enabled <Help> This alarm indicates the Built In Self Test mode is enabled <Condtype> CLIENT_BIST_… |
| 1.3.6.1.4.1.20044.115.2.2.2.240 | Tablepm600frs06AlmclientSfpAlmDdmTable | not-accessible | current | List of pm600frs06AlmclientSfpAlmDdm Article |
| 1.3.6.1.4.1.20044.115.2.2.2.240.1 | Rowpm600frs06AlmclientSfpAlmDdmEntry | not-accessible | current | Row definition for the pm600frs06AlmclientSfpAlmDdm table |
| 1.3.6.1.4.1.20044.115.2.2.2.240.1.1 | Columnpm600frs06AlmclientSfpAlmDdmIndex | read-only | current | Index definition for the pm600frs06AlmclientSfpAlmDdm table |
| 1.3.6.1.4.1.20044.115.2.2.2.240.1.2 | Columnpm600frs06AlmTxPwrLowAlaPortn | read-only | current | Client Trscv Tx Power Low :This OID indicates that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in… |
| 1.3.6.1.4.1.20044.115.2.2.2.240.1.3 | Columnpm600frs06AlmTxPwrHighAlaPortn | read-only | current | Client Trscv Tx Power High :This OID indicates that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm … |
| 1.3.6.1.4.1.20044.115.2.2.2.240.1.4 | Columnpm600frs06AlmTxBiasLowAlaPortn | read-only | current | Client Trscv Bias Low :This OID indicates that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm … |
| 1.3.6.1.4.1.20044.115.2.2.2.240.1.5 | Columnpm600frs06AlmTxBiasHighAlaPortn | read-only | current | Client Trscv Bias High :This OID indicates that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM <Help> Alar… |
| 1.3.6.1.4.1.20044.115.2.2.2.240.1.6 | Columnpm600frs06AlmVccLowAlaPortn | read-only | current | Client Trscv Power Supply Low :This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM <Help> Alar… |
| 1.3.6.1.4.1.20044.115.2.2.2.240.1.7 | Columnpm600frs06AlmVccHighAlaPortn | read-only | current | Client Trscv Power Supply High :This OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM <Help> Al… |
| 1.3.6.1.4.1.20044.115.2.2.2.240.1.8 | Columnpm600frs06AlmTempLowAlaPortn | read-only | current | Client Trscv Temp Low :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicat… |
| 1.3.6.1.4.1.20044.115.2.2.2.240.1.9 | Columnpm600frs06AlmTempHighAlaPortn | read-only | current | Client Trscv Temp High :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indic… |
| 1.3.6.1.4.1.20044.115.2.2.2.240.1.16 | Columnpm600frs06AlmRxPwrLowAlaPortn | read-only | current | Client Trscv Rx Power Low :This OID indicates that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm ind… |
| 1.3.6.1.4.1.20044.115.2.2.2.240.1.17 | Columnpm600frs06AlmRxPwrHighAlaPortn | read-only | current | Client Trscv Rx Power High :This OID indicates that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm i… |
| 1.3.6.1.4.1.20044.115.2.2.3 | Nodepm600frs06AlmClientCrit | |||
| 1.3.6.1.4.1.20044.115.2.2.3.8 | Tablepm600frs06AlmsynthAlmPortTable | not-accessible | current | List of pm600frs06AlmsynthAlmPort Article |
| 1.3.6.1.4.1.20044.115.2.2.3.8.1 | Rowpm600frs06AlmsynthAlmPortEntry | not-accessible | current | Row definition for the pm600frs06AlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.115.2.2.3.8.1.1 | Columnpm600frs06AlmsynthAlmPortIndex | read-only | current | Index definition for the pm600frs06AlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.115.2.2.3.8.1.2 | Columnpm600frs06AlmSfpAbsentPortn | read-only | current | Client Optical Module Absent :This OID indicates that the Transceiver is not present in the client port. <Help> This alarm indicates if the client transceiver … |
| 1.3.6.1.4.1.20044.115.2.2.3.8.1.3 | Columnpm600frs06AlmDdmAbsentPortn | read-only | current | DDM Supported On Client Trscv :This OID indicates that the Client transceiver supports the Digital Diagnostic Monitoring function <Help> This status indicates … |
| 1.3.6.1.4.1.20044.115.2.2.3.8.1.5 | Columnpm600frs06AlmHwFailAccPortn | read-only | current | Client HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Help> This alarm indicates a failure on client port, most pro… |
| 1.3.6.1.4.1.20044.115.2.2.3.8.1.6 | Columnpm600frs06AlmDwLsdPortn | read-only | current | Client Trscv Laser Shutdown :This OID indicates the Client transceiver laser is shutdown <Help> This status indicates if the client transceiver laser is shutdo… |
| 1.3.6.1.4.1.20044.115.2.2.3.8.1.7 | Columnpm600frs06AlmClientLocalOosPortn | read-only | current | Local Client Port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local c… |
| 1.3.6.1.4.1.20044.115.2.2.3.8.1.8 | Columnpm600frs06AlmClientRemoteOosPortn | read-only | current | Remote Client Port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the remot… |
| 1.3.6.1.4.1.20044.115.2.2.3.8.1.9 | Columnpm600frs06AlmDwCaisPortn | read-only | current | Client AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indicates if a Client Alarm Indication Signal is… |
| 1.3.6.1.4.1.20044.115.2.2.3.8.1.10 | Columnpm600frs06AlmSfpDdmWarningPortn | read-only | current | Warning On Client Trscv DDM :This OID indicates a warning is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Warning has be… |
| 1.3.6.1.4.1.20044.115.2.2.3.8.1.11 | Columnpm600frs06AlmSfpDdmAlmPortn | read-only | current | Alarm On Client Trscv DDM :This OID indicates an alarm is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Alarm has been de… |
| 1.3.6.1.4.1.20044.115.2.2.3.8.1.13 | Columnpm600frs06AlmFailAccPortn | read-only | current | Client Access Fail :This OID indicates a failure on the Client port <Help> This alarm indicates a failure on the Client port <Condtype> FAIL_ACC_1 <Probcause> … |
| 1.3.6.1.4.1.20044.115.2.2.3.8.1.14 | Columnpm600frs06AlmClientLoopbackOnPortn | read-only | current | Client Loopback Enabled :This OID indicates a loopback is enabled on the port <Help> This alarm indicates a loopback is enabled on the port <Condtype> CLIENT_L… |
| 1.3.6.1.4.1.20044.115.2.2.3.8.1.17 | Columnpm600frs06AlmUpCsfPortn | read-only | current | Client Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu… |
| 1.3.6.1.4.1.20044.115.2.3 | Nodepm600frs06AlmLine | |||
| 1.3.6.1.4.1.20044.115.2.3.1 | Nodepm600frs06AlmLineNurg | |||
| 1.3.6.1.4.1.20044.115.2.3.1.184 | Tablepm600frs06AlmlineNetworkLaneAlarmWarning1Table | not-accessible | current | List of pm600frs06AlmlineNetworkLaneAlarmWarning1 Article |
| 1.3.6.1.4.1.20044.115.2.3.1.184.1 | Rowpm600frs06AlmlineNetworkLaneAlarmWarning1Entry | not-accessible | current | Row definition for the pm600frs06AlmlineNetworkLaneAlarmWarning1 table |
| 1.3.6.1.4.1.20044.115.2.3.1.184.1.1 | Columnpm600frs06AlmlineNetworkLaneAlarmWarning1Index | read-only | current | Index definition for the pm600frs06AlmlineNetworkLaneAlarmWarning1 table |
| 1.3.6.1.4.1.20044.115.2.3.1.184.1.2 | Columnpm600frs06AlmLineRxPowerLowAlarmPortn | read-only | current | Line Trscv Rx Power Low Alarm :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicat… |
| 1.3.6.1.4.1.20044.115.2.3.1.184.1.3 | Columnpm600frs06AlmLineRxPowerLowWarningPortn | read-only | current | Line Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning ind… |
| 1.3.6.1.4.1.20044.115.2.3.1.184.1.4 | Columnpm600frs06AlmLineRxPowerHighWarningPortn | read-only | current | Line Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning i… |
| 1.3.6.1.4.1.20044.115.2.3.1.184.1.5 | Columnpm600frs06AlmLineRxPowerHighAlarmPortn | read-only | current | Line Trscv Rx Power High Alarm :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indic… |
| 1.3.6.1.4.1.20044.115.2.3.1.184.1.6 | Columnpm600frs06AlmLineLaserTempLowAlarmPortn | read-only | current | Line Trscv Tx Laser Temp Low Alarm :This OID indicates that the Trscv Tx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help>… |
| 1.3.6.1.4.1.20044.115.2.3.1.184.1.7 | Columnpm600frs06AlmLineLaserTempLowWarningPortn | read-only | current | Line Trscv Tx Laser Temp Low Warning :This OID indicates that the Trscv Tx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Hel… |
| 1.3.6.1.4.1.20044.115.2.3.1.184.1.8 | Columnpm600frs06AlmLineLaserTempHighWarningPortn | read-only | current | Line Trscv Tx Laser Temp High Warning :This OID indicates that the Trscv Tx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <H… |
| 1.3.6.1.4.1.20044.115.2.3.1.184.1.9 | Columnpm600frs06AlmLineLaserTempHighAlarmPortn | read-only | current | Line Trscv Tx Laser Temp High Alarm :This OID indicates that the Trscv Tx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Hel… |
| 1.3.6.1.4.1.20044.115.2.3.1.184.1.10 | Columnpm600frs06AlmLineTxPowerLowAlarmPortn | read-only | current | Line Trscv Tx Power Low Alarm :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indica… |
| 1.3.6.1.4.1.20044.115.2.3.1.184.1.11 | Columnpm600frs06AlmLineTxPowerLowWarningPortn | read-only | current | Line Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning in… |
| 1.3.6.1.4.1.20044.115.2.3.1.184.1.12 | Columnpm600frs06AlmLineTxPowerHighWarningPortn | read-only | current | Line Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warning … |
| 1.3.6.1.4.1.20044.115.2.3.1.184.1.13 | Columnpm600frs06AlmLineTxPowerHighAlarmPortn | read-only | current | Line Trscv Tx Power High Alarm :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indi… |
| 1.3.6.1.4.1.20044.115.2.3.1.184.1.14 | Columnpm600frs06AlmLineBiasLowAlarmPortn | read-only | current | Line Trscv Tx Bias Low Alarm :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alarm i… |
| 1.3.6.1.4.1.20044.115.2.3.1.184.1.15 | Columnpm600frs06AlmLineBiasLowWarningPortn | read-only | current | Line Trscv Tx Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warni… |
| 1.3.6.1.4.1.20044.115.2.3.1.184.1.16 | Columnpm600frs06AlmLineBiasHighWarningPortn | read-only | current | Line Trscv Tx Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> War… |
| 1.3.6.1.4.1.20044.115.2.3.1.184.1.17 | Columnpm600frs06AlmLineBiasHighAlarmPortn | read-only | current | Line Trscv Tx Bias High Alarm :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Alarm… |
| 1.3.6.1.4.1.20044.115.2.3.1.188 | Tablepm600frs06AlmlineNetworkLaneAlarmWarning2Table | not-accessible | current | List of pm600frs06AlmlineNetworkLaneAlarmWarning2 Article |
| 1.3.6.1.4.1.20044.115.2.3.1.188.1 | Rowpm600frs06AlmlineNetworkLaneAlarmWarning2Entry | not-accessible | current | Row definition for the pm600frs06AlmlineNetworkLaneAlarmWarning2 table |
| 1.3.6.1.4.1.20044.115.2.3.1.188.1.1 | Columnpm600frs06AlmlineNetworkLaneAlarmWarning2Index | read-only | current | Index definition for the pm600frs06AlmlineNetworkLaneAlarmWarning2 table |
| 1.3.6.1.4.1.20044.115.2.3.1.188.1.2 | Columnpm600frs06AlmTxModulatorBiasLowAlarmPortn | read-only | current | Line Trscv Tx Modulator Bias Low Alarm :This OID indicates that the Trscv Tx modulator bias current is lower than the threshold value written in the Trscv EEPR… |
| 1.3.6.1.4.1.20044.115.2.3.1.188.1.3 | Columnpm600frs06AlmTxModulatorBiasLowWarningPortn | read-only | current | Line Trscv Tx Modulator Bias Low Warning :This OID indicates that the Trscv Tx modulator bias current is lower than the threshold value written in the Trscv EE… |
| 1.3.6.1.4.1.20044.115.2.3.1.188.1.4 | Columnpm600frs06AlmTxModulatorBiasHighWarningPortn | read-only | current | Line Trscv Tx Modulator Bias High Warning :This OID indicates that the Trscv Tx modulator bias current is higher than the threshold value written in the Trscv … |
| 1.3.6.1.4.1.20044.115.2.3.1.188.1.5 | Columnpm600frs06AlmTxModulatorBiasHighAlarmPortn | read-only | current | Line Trscv Tx Modulator Bias High Alarm :This OID indicates that the Trscv Tx modulator bias current is higher than the threshold value written in the Trscv EE… |
| 1.3.6.1.4.1.20044.115.2.3.1.188.1.6 | Columnpm600frs06AlmRxLaserTempLowAlarmPortn | read-only | current | Line Trscv Rx Laser Temp Low Alarm :This OID indicates that the Trscv Rx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help>… |
| 1.3.6.1.4.1.20044.115.2.3.1.188.1.7 | Columnpm600frs06AlmRxLaserTempLowWarningPortn | read-only | current | Line Trscv Rx Laser Temp Low Warning :This OID indicates that the Trscv Rx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Hel… |
| 1.3.6.1.4.1.20044.115.2.3.1.188.1.8 | Columnpm600frs06AlmRxLaserTempHighWarningPortn | read-only | current | Line Trscv Rx Laser Temp High Warning :This OID indicates that the Trscv Rx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <H… |
| 1.3.6.1.4.1.20044.115.2.3.1.188.1.9 | Columnpm600frs06AlmRxLaserTempHighAlarmPortn | read-only | current | Line Trscv Rx Laser Temp High Alarm :This OID indicates that the Trscv Rx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Hel… |
| 1.3.6.1.4.1.20044.115.2.3.1.188.1.10 | Columnpm600frs06AlmRxLaserOutputLowAlarmPortn | read-only | current | Line Trscv Rx Output Power Low Alarm :This OID indicates that the Trscv Rx output power is lower than the threshold value written in the Trscv EEPROM <Help> Al… |
| 1.3.6.1.4.1.20044.115.2.3.1.188.1.11 | Columnpm600frs06AlmRxLaserOutputLowWarningPortn | read-only | current | Line Trscv Rx Output Power Low Warning :This OID indicates that the Trscv Rx output power is lower than the threshold value written in the Trscv EEPROM <Help> … |
| 1.3.6.1.4.1.20044.115.2.3.1.188.1.12 | Columnpm600frs06AlmRxLaserOutputHighWarningPortn | read-only | current | Line Trscv Rx Output Power High Warning :This OID indicates that the Trscv Rx output power is higher than the threshold value written in the Trscv EEPROM <Help… |
| 1.3.6.1.4.1.20044.115.2.3.1.188.1.13 | Columnpm600frs06AlmRxLaserOutputHighAlarmPortn | read-only | current | Line Trscv Rx Output Power High Alarm :This OID indicates that the Trscv Rx output power is higher than the threshold value written in the Trscv EEPROM <Help> … |
| 1.3.6.1.4.1.20044.115.2.3.1.188.1.14 | Columnpm600frs06AlmRxLaserBiasLowAlarmPortn | read-only | current | Line Trscv Rx Bias Low Alarm :This OID indicates that the Trscv Rx laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alar… |
| 1.3.6.1.4.1.20044.115.2.3.1.188.1.15 | Columnpm600frs06AlmRxLaserBiasLowWarningPortn | read-only | current | Line Trscv Rx Bias Low Warning :This OID indicates that the Trscv Rx laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Wa… |
| 1.3.6.1.4.1.20044.115.2.3.1.188.1.16 | Columnpm600frs06AlmRxLaserBiasHighWarningPortn | read-only | current | Line Trscv Rx Bias High Warning :This OID indicates that the Trscv Rx laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> … |
| 1.3.6.1.4.1.20044.115.2.3.1.188.1.17 | Columnpm600frs06AlmRxLaserBiasHighAlarmPortn | read-only | current | Line Trscv Rx Bias High Alarm :This OID indicates that the Trscv Rx laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Al… |
| 1.3.6.1.4.1.20044.115.2.3.2 | Nodepm600frs06AlmLineUrg | |||
| 1.3.6.1.4.1.20044.115.2.3.2.196 | Tablepm600frs06AlmlineHostLaneFaultTable | not-accessible | current | List of pm600frs06AlmlineHostLaneFault Article |
| 1.3.6.1.4.1.20044.115.2.3.2.196.1 | Rowpm600frs06AlmlineHostLaneFaultEntry | not-accessible | current | Row definition for the pm600frs06AlmlineHostLaneFault table |
| 1.3.6.1.4.1.20044.115.2.3.2.196.1.1 | Columnpm600frs06AlmlineHostLaneFaultIndex | read-only | current | Index definition for the pm600frs06AlmlineHostLaneFault table |
| 1.3.6.1.4.1.20044.115.2.3.2.196.1.2 | Columnpm600frs06AlmLineInputLossOfSignalPortn | read-only | current | Line Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Line Trscv <Help> Alarm indicating a Loss of Signal is detected on the Line T… |
| 1.3.6.1.4.1.20044.115.2.3.2.196.1.3 | Columnpm600frs06AlmLineLossOfFramePortn | read-only | current | Line Loss Of Frame :This OID indicates the module is not aligned with the incoming Line signal <Help> Alarm indicating the module is not aligned with the incom… |
| 1.3.6.1.4.1.20044.115.2.3.2.196.1.4 | Columnpm600frs06AlmLineSmBdiInsertedPortn | read-only | current | Line SM BDI Inserted :This OID indicates a SM Backward Defect Indication is inserted on the outgoing Line signal <Help> Status indicating a SM Backward Defect … |
| 1.3.6.1.4.1.20044.115.2.3.2.196.1.5 | Columnpm600frs06AlmLineSmBdiDetectedPortn | read-only | current | Line SM BDI Detected :This OID indicates a SM Backward Defect Indication is detected on the incoming Line signal <Help> Alarm indicating a SM Backward Defect I… |
| 1.3.6.1.4.1.20044.115.2.3.2.196.1.6 | Columnpm600frs06AlmLineSmIaeInsertedPortn | read-only | current | Line SM IAE Inserted :This OID indicates a SM Incoming Alignment Error is inserted on the outgoing Line signal <Help> Status indicating a SM Incoming Alignment… |
| 1.3.6.1.4.1.20044.115.2.3.2.196.1.7 | Columnpm600frs06AlmLineSmIaeDetectedPortn | read-only | current | Line SM IAE Detected :This OID indicates a SM Incoming Alignment Error is detected on the incoming Line signal <Help> Alarm indicating a SM Incoming Alignment … |
| 1.3.6.1.4.1.20044.115.2.3.2.196.1.10 | Columnpm600frs06AlmLineEncryptionFailurePortn | read-only | current | Encryption Failure :This OID indicates the encryption mechanism failed, impacting the traffic (the line traffic is down). <Help> This alarm indicates the encry… |
| 1.3.6.1.4.1.20044.115.2.3.3 | Nodepm600frs06AlmLineCrit | |||
| 1.3.6.1.4.1.20044.115.2.3.3.40 | Tablepm600frs06AlmsynthAlmLineTable | not-accessible | current | List of pm600frs06AlmsynthAlmLine Article |
| 1.3.6.1.4.1.20044.115.2.3.3.40.1 | Rowpm600frs06AlmsynthAlmLineEntry | not-accessible | current | Row definition for the pm600frs06AlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.115.2.3.3.40.1.1 | Columnpm600frs06AlmsynthAlmLineIndex | read-only | current | Index definition for the pm600frs06AlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.115.2.3.3.40.1.2 | Columnpm600frs06AlmXfpAbsentPortn | read-only | current | Line Optical Module Absent :This OID indicates that the line optical interface is not present. <Help> This alarm indicates if the line transceiver is not plugg… |
| 1.3.6.1.4.1.20044.115.2.3.3.40.1.3 | Columnpm600frs06AlmXfpInitNotComplPortn | read-only | current | Line Optical Module Ready :This OID indicates that the optical interface is not operational. <Help> This status indicates if the line transceiver has been corr… |
| 1.3.6.1.4.1.20044.115.2.3.3.40.1.5 | Columnpm600frs06AlmLineHwFailPortn | read-only | current | Line Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Help> This alarm indicates a failure on line port, most pr… |
| 1.3.6.1.4.1.20044.115.2.3.3.40.1.6 | Columnpm600frs06AlmXfpTxOffPortn | read-only | current | Line Trscv Laser Shutdown :This OID indicates the Line transceiver laser is shutdown <Help> This status indicates if the Line transceiver laser is shutdown <Co… |
| 1.3.6.1.4.1.20044.115.2.3.3.40.1.7 | Columnpm600frs06AlmLineLocalOosPortn | read-only | current | Line Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service… |
| 1.3.6.1.4.1.20044.115.2.3.3.40.1.9 | Columnpm600frs06AlmUpRdiInsPortn | read-only | current | MS-RDI/L-RDI Inserted On Line :This OID indicates an upstream MS-RDI/L-RDI has been inserted in the outgoing 10 Gb/s SDH/SONET signal. <Help> This status indic… |
| 1.3.6.1.4.1.20044.115.2.3.3.40.1.10 | Columnpm600frs06AlmLineDdmWarningPortn | read-only | current | Warning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Warning has… |
| 1.3.6.1.4.1.20044.115.2.3.3.40.1.11 | Columnpm600frs06AlmLineDdmAlmPortn | read-only | current | Alarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Alarm has been… |
| 1.3.6.1.4.1.20044.115.2.3.3.40.1.13 | Columnpm600frs06AlmLineFailPortn | read-only | current | Line Port Failure :This OID indicates a failure on the line port <Help> This alarm indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipm… |
| 1.3.6.1.4.1.20044.115.2.3.3.40.1.14 | Columnpm600frs06AlmLineLoopbackOnPortn | read-only | current | Line Loopback Enabled :This OID indicates a loopback is enabled on the port <Help> This alarm indicates a loopback is enabled on the port <Condtype> LINE_LOOPB… |
| 1.3.6.1.4.1.20044.115.2.3.3.40.1.17 | Columnpm600frs06AlmLineActivePortn | read-only | current | Line Active :This OID indicates whether the line is active or standby. <Help> This status indicates whether the line is active or standby. <Condtype> LINE_ACTI… |
| 1.3.6.1.4.1.20044.115.3 | Nodepm600frs06measures | |||
| 1.3.6.1.4.1.20044.115.3.1 | Nodepm600frs06MesrOther | |||
| 1.3.6.1.4.1.20044.115.3.1.0 | Scalarpm600frs06Mesrsynth0 | read-only | deprecated | Not Used : |
| 1.3.6.1.4.1.20044.115.3.1.1 | Scalarpm600frs06Mesrsynth1 | read-only | deprecated | Not Used : |
| 1.3.6.1.4.1.20044.115.3.1.7 | Scalarpm600frs06MesrpmIntervalNumber | read-only | current | PM Interval Counter : |
| 1.3.6.1.4.1.20044.115.3.1.196 | Scalarpm600frs06MesrlineNetTxLaserOutputPwrAverage | read-only | current | Average Line Trscv Tx Power :This OID gives the average Tx Laser transmit power value among the network lanes of the Line Transceiver, read in the DDM (Digital… |
| 1.3.6.1.4.1.20044.115.3.1.197 | Scalarpm600frs06MesrlineNetTxLaserTempAverage | read-only | current | Average Line Trscv Tx Laser Temperature :This OID gives the average Tx Laser Temperature value among the network lanes of the Line Transceiver, read from the D… |
| 1.3.6.1.4.1.20044.115.3.1.198 | Scalarpm600frs06MesrlineNetTxBiasCurrentAverage | read-only | current | Average Line Trscv Tx Laser Bias :This OID gives the average Tx Laser Bias value among the network lanes of the Line Transceiver, read from the DDM (Digital Di… |
| 1.3.6.1.4.1.20044.115.3.1.199 | Scalarpm600frs06MesrlineNetRxInputPwrAverage | read-only | current | Average Line Trscv Rx Power :This OID gives the average Receive power value among the network lanes of the Line Transceiver, read in the DDM (Digital Diagnosti… |
| 1.3.6.1.4.1.20044.115.3.1.200 | Scalarpm600frs06MesrlineResidualChromaticDispAverage | read-only | current | Average Residual Chromatic Dispersion :This OID gives the average Residual Chromatic Dispersion on the Line interface since the last measure reset (Dispersion … |
| 1.3.6.1.4.1.20044.115.3.1.201 | Scalarpm600frs06MesrlineDiffGroupDelayAverage | read-only | current | Average Differential Group Delay :This OID gives the average Group Delay on the Line interface since the last measure reset (Delay = AV_S16) (Unit = ps)<Help> … |
| 1.3.6.1.4.1.20044.115.3.1.202 | Scalarpm600frs06MesrlineQFactorAverage | read-only | current | Average Q Factor :This OID gives the average Q Factor on the Line interface since the last measure reset (Q Factor = AV_U16) (Unit = dB) <Help> This measure gi… |
| 1.3.6.1.4.1.20044.115.3.1.203 | Scalarpm600frs06MesrlineCarrierFreqOffsetAverage | read-only | current | Average Carrier Frequency Offset :This OID gives the average Carrier Frequency Offset on the Line interface since the last measure reset (Offset = AV_S16) (Uni… |
| 1.3.6.1.4.1.20044.115.3.1.204 | Scalarpm600frs06MesrlineOsnrAverage | read-only | current | Average OSNR :This OID gives the average OSNR on the Line interface since the last measure reset (OSNR = AV_S16/10) (Unit = dB)<Help> This measure gives the av… |
| 1.3.6.1.4.1.20044.115.3.1.212 | Scalarpm600frs06MesrlineNetTxLaserOutputPwrMin | read-only | current | Min Line Trscv Tx Power :This OID gives the minimum Tx Laser transmit power value among the network lanes of the Line Transceiver, read in the DDM (Digital Dia… |
| 1.3.6.1.4.1.20044.115.3.1.213 | Scalarpm600frs06MesrlineNetTxLaserTempMin | read-only | current | Min Line Trscv Tx Laser Temperature :This OID gives the minimum Tx Laser Temperature value among the network lanes of the Line Transceiver, read from the DDM (… |
| 1.3.6.1.4.1.20044.115.3.1.214 | Scalarpm600frs06MesrlineNetTxBiasCurrentMin | read-only | current | Min Line Trscv Tx Laser Bias :This OID gives the minimum Tx Laser Bias value among the network lanes of the Line Transceiver, read from the DDM (Digital Diagno… |
| 1.3.6.1.4.1.20044.115.3.1.215 | Scalarpm600frs06MesrlineNetRxInputPwrMin | read-only | current | Min Line Trscv Rx Power :This OID gives the minimum Receive power value among the network lanes of the Line Transceiver, read in the DDM (Digital Diagnostic Mo… |
| 1.3.6.1.4.1.20044.115.3.1.216 | Scalarpm600frs06MesrlineResidualChromaticDispMin | read-only | current | Min Residual Chromatic Dispersion :This OID gives the minimum Residual Chromatic Dispersion on the Line interface since the last measure reset (Dispersion = AV… |
| 1.3.6.1.4.1.20044.115.3.1.217 | Scalarpm600frs06MesrlineDiffGroupDelayMin | read-only | current | Min Differential Group Delay :This OID gives the minimum Differential Group Delay on the Line interface since the last measure reset (Delay = AV_S16) (Unit = p… |
| 1.3.6.1.4.1.20044.115.3.1.218 | Scalarpm600frs06MesrlineQFactorMin | read-only | current | Min Q Factor :This OID gives the minimum Q Factor on the Line interface since the last measure reset (Q Factor = AV_U16) (Unit = dB)<Help> This measure gives t… |
| 1.3.6.1.4.1.20044.115.3.1.219 | Scalarpm600frs06MesrlineCarrierFreqOffsetMin | read-only | current | Min Carrier Frequency Offset :This OID gives the minimum Carrier Frequency Offset on the Line interface since the last measure reset (Offset = AV_S16) (Unit = … |
| 1.3.6.1.4.1.20044.115.3.1.220 | Scalarpm600frs06MesrlineOsnrMin | read-only | current | Min OSNR :This OID gives the minimum OSNR on the Line interface since the last measure reset (OSNR = AV_S16/10) (Unit = dB)<Help> This measure gives the minimu… |
| 1.3.6.1.4.1.20044.115.3.1.228 | Scalarpm600frs06MesrlineNetTxLaserOutputPwrMax | read-only | current | Max Line Trscv Tx Power :This OID gives the maximum Tx Laser transmit power value among the network lanes of the Line Transceiver, read in the DDM (Digital Dia… |
| 1.3.6.1.4.1.20044.115.3.1.229 | Scalarpm600frs06MesrlineNetTxLaserTempMax | read-only | current | Max Line Trscv Tx Laser Temperature :This OID gives the maximum Tx Laser Temperature value among the network lanes of the Line Transceiver, read from the DDM (… |
| 1.3.6.1.4.1.20044.115.3.1.230 | Scalarpm600frs06MesrlineNetTxBiasCurrentMax | read-only | current | Max Line Trscv Tx Laser Bias :This OID gives the maximum Tx Laser Bias value among the network lanes of the Line Transceiver, read from the DDM (Digital Diagno… |
| 1.3.6.1.4.1.20044.115.3.1.231 | Scalarpm600frs06MesrlineNetRxInputPwrMax | read-only | current | Max Line Trscv Rx Power :This OID gives the maximum Receive power value among the network lanes of the Line Transceiver, read in the DDM (Digital Diagnostic Mo… |
| 1.3.6.1.4.1.20044.115.3.1.232 | Scalarpm600frs06MesrlineResidualChromaticDispMax | read-only | current | Max Residual Chromatic Dispersion :This OID gives the maximum Residual Chromatic Dispersion on the Line interface since the last measure reset (Dispersion = AV… |
| 1.3.6.1.4.1.20044.115.3.1.233 | Scalarpm600frs06MesrlineDiffGroupDelayMax | read-only | current | Max Differential Group Delay :This OID gives the maximum Differential Group Delay on the Line interface since the last measure reset (Delay = AV_S16) (Unit = p… |
| 1.3.6.1.4.1.20044.115.3.1.234 | Scalarpm600frs06MesrlineQFactorMax | read-only | current | Max Q Factor :This OID gives the maximum Q Factor on the Line interface since the last measure reset (Q Factor = AV_U16) (Unit = dB)<Help> This measure gives t… |
| 1.3.6.1.4.1.20044.115.3.1.235 | Scalarpm600frs06MesrlineCarrierFreqOffsetMax | read-only | current | Max Carrier Frequency Offset :This OID gives the maximum Carrier Frequency Offset on the Line interface since the last measure reset (Offset = AV_S16) (Unit = … |
| 1.3.6.1.4.1.20044.115.3.1.236 | Scalarpm600frs06MesrlineOsnrMax | read-only | current | Max OSNR :This OID gives the maximum OSNR on the Line interface since the last measure reset (OSNR = AV_S16/10) (Unit = dB)<Help> This measure gives the maximu… |
| 1.3.6.1.4.1.20044.115.3.1.240 | Scalarpm600frs06Mesrtrscv1Temp | read-only | current | Client1 Trscv Temperature :This OID gives the temperature value of the Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV_S16/256… |
| 1.3.6.1.4.1.20044.115.3.1.241 | Scalarpm600frs06Mesrtrscv2Temp | read-only | current | Client2 Trscv Temperature :This OID gives the temperature value of the Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV_S16/256… |
| 1.3.6.1.4.1.20044.115.3.1.242 | Scalarpm600frs06Mesrtrscv3Temp | read-only | current | Client3 Trscv Temperature :This OID gives the temperature value of the Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV_S16/256… |
| 1.3.6.1.4.1.20044.115.3.1.243 | Scalarpm600frs06Mesrtrscv4Temp | read-only | current | Client4 Trscv Temperature :This OID gives the temperature value of the Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV_S16/256… |
| 1.3.6.1.4.1.20044.115.3.1.244 | Scalarpm600frs06Mesrtrscv5Temp | read-only | current | Client5 Trscv Temperature :This OID gives the temperature value of the Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV_S16/256… |
| 1.3.6.1.4.1.20044.115.3.1.245 | Scalarpm600frs06Mesrtrscv6Temp | read-only | current | Client6 Trscv Temperature :This OID gives the temperature value of the Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV_S16/256… |
| 1.3.6.1.4.1.20044.115.3.1.246 | Scalarpm600frs06Mesrtrscv1PowerSupply | read-only | current | Client1 Trscv Voltage :This OID gives the voltage value of the QSFP plugged into the port, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV_U16/… |
| 1.3.6.1.4.1.20044.115.3.1.247 | Scalarpm600frs06Mesrtrscv2PowerSupply | read-only | current | Client2 Trscv Voltage :This OID gives the voltage value of the QSFP plugged into the port, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV_U16/… |
| 1.3.6.1.4.1.20044.115.3.1.248 | Scalarpm600frs06Mesrtrscv3PowerSupply | read-only | current | Client3 Trscv Voltage :This OID gives the voltage value of the QSFP plugged into the port, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV_U16/… |
| 1.3.6.1.4.1.20044.115.3.1.249 | Scalarpm600frs06Mesrtrscv4PowerSupply | read-only | current | Client4 Trscv Voltage :This OID gives the voltage value of the QSFP plugged into the port, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV_U16/… |
| 1.3.6.1.4.1.20044.115.3.1.250 | Scalarpm600frs06Mesrtrscv5PowerSupply | read-only | current | Client5 Trscv Voltage :This OID gives the voltage value of the QSFP plugged into the port, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV_U16/… |
| 1.3.6.1.4.1.20044.115.3.1.251 | Scalarpm600frs06Mesrtrscv6PowerSupply | read-only | current | Client6 Trscv Voltage :This OID gives the voltage value of the QSFP plugged into the port, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV_U16/… |
| 1.3.6.1.4.1.20044.115.3.1.252 | Scalarpm600frs06MesrregVoltage | read-only | current | Regulator Voltage :This OID gives the voltage value of the Regulator (Voltage = AV_U16) (Unit = mV) <Help> This Measure gives the Regulator Voltage |
| 1.3.6.1.4.1.20044.115.3.1.253 | Scalarpm600frs06MesrregCurrent | read-only | current | Regulator Current :This OID gives the current value of the Regulator (Current = AV_U16/1000) (Unit = A) <Help> This Measure gives the Regulator Current |
| 1.3.6.1.4.1.20044.115.3.1.254 | Scalarpm600frs06MesrregTemp | read-only | current | Regulator Temperature :This OID gives the temperature value of the Regulator (Temperature = AV_S16) (Unit = C) <Help> This Measure gives the Regulator Temperat… |
| 1.3.6.1.4.1.20044.115.3.1.500 | Scalarpm600frs06MesrmoduleTempMin | read-only | current | Min Module Temperature :This OID gives the minimum temperature value of the Module (Temperature = AV_S16/256) (Unit = C) <Help> This Measure gives the minimum … |
| 1.3.6.1.4.1.20044.115.3.1.501 | Scalarpm600frs06MesrmoduleTempMax | read-only | current | Max Module Temperature :This OID gives the maximum temperature value of the Module (Temperature = AV_S16/256) (Unit = C) <Help> This Measure gives the maximum … |
| 1.3.6.1.4.1.20044.115.3.2 | Nodepm600frs06MesrClient | |||
| 1.3.6.1.4.1.20044.115.3.2.16 | Tablepm600frs06MesrclientTxPwrMinTable | not-accessible | current | List of pm600frs06MesrclientTxPwrMin Article |
| 1.3.6.1.4.1.20044.115.3.2.16.1 | Rowpm600frs06MesrclientTxPwrMinEntry | not-accessible | current | Row definition for the pm600frs06MesrclientTxPwrMin table |
| 1.3.6.1.4.1.20044.115.3.2.16.1.1 | Columnpm600frs06MesrclientTxPwrMinIndex | read-only | current | Index definition for the pm600frs06MesrclientTxPwrMin table |
| 1.3.6.1.4.1.20044.115.3.2.16.1.2 | Columnpm600frs06MesrclientTxPwrMinPortn | read-only | current | Min Client Trscv Tx Power Per Lane :This OID gives the minimum transmit power value among the network lanes of the Client Transceiver, read from the DDM (Digit… |
| 1.3.6.1.4.1.20044.115.3.2.48 | Tablepm600frs06MesrclientRxPwrMinTable | not-accessible | current | List of pm600frs06MesrclientRxPwrMin Article |
| 1.3.6.1.4.1.20044.115.3.2.48.1 | Rowpm600frs06MesrclientRxPwrMinEntry | not-accessible | current | Row definition for the pm600frs06MesrclientRxPwrMin table |
| 1.3.6.1.4.1.20044.115.3.2.48.1.1 | Columnpm600frs06MesrclientRxPwrMinIndex | read-only | current | Index definition for the pm600frs06MesrclientRxPwrMin table |
| 1.3.6.1.4.1.20044.115.3.2.48.1.2 | Columnpm600frs06MesrclientRxPwrMinPortn | read-only | current | Min Client Trscv Rx Power Per Lane :This OID gives the minimum receive power value among the network lanes of the Client Transceiver, read from the DDM (Digita… |
| 1.3.6.1.4.1.20044.115.3.2.80 | Tablepm600frs06MesrclientTxPwrMaxTable | not-accessible | current | List of pm600frs06MesrclientTxPwrMax Article |
| 1.3.6.1.4.1.20044.115.3.2.80.1 | Rowpm600frs06MesrclientTxPwrMaxEntry | not-accessible | current | Row definition for the pm600frs06MesrclientTxPwrMax table |
| 1.3.6.1.4.1.20044.115.3.2.80.1.1 | Columnpm600frs06MesrclientTxPwrMaxIndex | read-only | current | Index definition for the pm600frs06MesrclientTxPwrMax table |
| 1.3.6.1.4.1.20044.115.3.2.80.1.2 | Columnpm600frs06MesrclientTxPwrMaxPortn | read-only | current | Max Client Trscv Tx Power Per Lane :This OID gives the maximum transmit power value among the network lanes of the Client Transceiver, read from the DDM (Digit… |
| 1.3.6.1.4.1.20044.115.3.2.112 | Tablepm600frs06MesrclientRxPwrMaxTable | not-accessible | current | List of pm600frs06MesrclientRxPwrMax Article |
| 1.3.6.1.4.1.20044.115.3.2.112.1 | Rowpm600frs06MesrclientRxPwrMaxEntry | not-accessible | current | Row definition for the pm600frs06MesrclientRxPwrMax table |
| 1.3.6.1.4.1.20044.115.3.2.112.1.1 | Columnpm600frs06MesrclientRxPwrMaxIndex | read-only | current | Index definition for the pm600frs06MesrclientRxPwrMax table |
| 1.3.6.1.4.1.20044.115.3.2.112.1.2 | Columnpm600frs06MesrclientRxPwrMaxPortn | read-only | current | Max Client Trscv Rx Power Per Lane :This OID gives the maximum receive power value among the network lanes of the Client Transceiver, read in the DDM (Digital … |
| 1.3.6.1.4.1.20044.115.3.2.256 | Tablepm600frs06MesrclientTxCompositePwrTable | not-accessible | current | List of pm600frs06MesrclientTxCompositePwr Article |
| 1.3.6.1.4.1.20044.115.3.2.256.1 | Rowpm600frs06MesrclientTxCompositePwrEntry | not-accessible | current | Row definition for the pm600frs06MesrclientTxCompositePwr table |
| 1.3.6.1.4.1.20044.115.3.2.256.1.1 | Columnpm600frs06MesrclientTxCompositePwrIndex | read-only | current | Index definition for the pm600frs06MesrclientTxCompositePwr table |
| 1.3.6.1.4.1.20044.115.3.2.256.1.2 | Columnpm600frs06MesrclientTxCompositePwrPortn | read-only | current | Client Composite Tx Power :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver, read from the DDM (… |
| 1.3.6.1.4.1.20044.115.3.2.288 | Tablepm600frs06MesrclientRxCompositePwrTable | not-accessible | current | List of pm600frs06MesrclientRxCompositePwr Article |
| 1.3.6.1.4.1.20044.115.3.2.288.1 | Rowpm600frs06MesrclientRxCompositePwrEntry | not-accessible | current | Row definition for the pm600frs06MesrclientRxCompositePwr table |
| 1.3.6.1.4.1.20044.115.3.2.288.1.1 | Columnpm600frs06MesrclientRxCompositePwrIndex | read-only | current | Index definition for the pm600frs06MesrclientRxCompositePwr table |
| 1.3.6.1.4.1.20044.115.3.2.288.1.2 | Columnpm600frs06MesrclientRxCompositePwrPortn | read-only | current | Client Composite Rx Power :This OID gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver, read from the DDM (Di… |
| 1.3.6.1.4.1.20044.115.3.2.416 | Tablepm600frs06MesrclientTempMinTable | not-accessible | current | List of pm600frs06MesrclientTempMin Article |
| 1.3.6.1.4.1.20044.115.3.2.416.1 | Rowpm600frs06MesrclientTempMinEntry | not-accessible | current | Row definition for the pm600frs06MesrclientTempMin table |
| 1.3.6.1.4.1.20044.115.3.2.416.1.1 | Columnpm600frs06MesrclientTempMinIndex | read-only | current | Index definition for the pm600frs06MesrclientTempMin table |
| 1.3.6.1.4.1.20044.115.3.2.416.1.2 | Columnpm600frs06MesrclientTempMinPortn | read-only | current | Min Client Trscv Temperature :This OID gives the minimum temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temper… |
| 1.3.6.1.4.1.20044.115.3.2.448 | Tablepm600frs06MesrclientTempMaxTable | not-accessible | current | List of pm600frs06MesrclientTempMax Article |
| 1.3.6.1.4.1.20044.115.3.2.448.1 | Rowpm600frs06MesrclientTempMaxEntry | not-accessible | current | Row definition for the pm600frs06MesrclientTempMax table |
| 1.3.6.1.4.1.20044.115.3.2.448.1.1 | Columnpm600frs06MesrclientTempMaxIndex | read-only | current | Index definition for the pm600frs06MesrclientTempMax table |
| 1.3.6.1.4.1.20044.115.3.2.448.1.2 | Columnpm600frs06MesrclientTempMaxPortn | read-only | current | Max Client Trscv Temperature :This OID gives the maximum temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temper… |
| 1.3.6.1.4.1.20044.115.3.3 | Nodepm600frs06MesrLine | |||
| 1.3.6.1.4.1.20044.115.3.3.12 | Scalarpm600frs06MesrlineMsaTemp | read-only | current | Line Trscv Temperature :This OID gives the temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV_S16/2… |
| 1.3.6.1.4.1.20044.115.3.3.13 | Scalarpm600frs06MesrlineMsa3v3Voltage | read-only | current | Line Trscv Voltage :This OID gives the 3V3 voltage value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV_U16/10000) (U… |
| 1.3.6.1.4.1.20044.115.3.3.144 | Tablepm600frs06MesrlineNetTxLaserOutputPwrTable | not-accessible | current | List of pm600frs06MesrlineNetTxLaserOutputPwr Article |
| 1.3.6.1.4.1.20044.115.3.3.144.1 | Rowpm600frs06MesrlineNetTxLaserOutputPwrEntry | not-accessible | current | Row definition for the pm600frs06MesrlineNetTxLaserOutputPwr table |
| 1.3.6.1.4.1.20044.115.3.3.144.1.1 | Columnpm600frs06MesrlineNetTxLaserOutputPwrIndex | read-only | current | Index definition for the pm600frs06MesrlineNetTxLaserOutputPwr table |
| 1.3.6.1.4.1.20044.115.3.3.144.1.2 | Columnpm600frs06MesrlineNetTxLaserOutputPwrPortn | read-only | current | Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power =… |
| 1.3.6.1.4.1.20044.115.3.3.148 | Tablepm600frs06MesrlineNetTxLaserTempTable | not-accessible | current | List of pm600frs06MesrlineNetTxLaserTemp Article |
| 1.3.6.1.4.1.20044.115.3.3.148.1 | Rowpm600frs06MesrlineNetTxLaserTempEntry | not-accessible | current | Row definition for the pm600frs06MesrlineNetTxLaserTemp table |
| 1.3.6.1.4.1.20044.115.3.3.148.1.1 | Columnpm600frs06MesrlineNetTxLaserTempIndex | read-only | current | Index definition for the pm600frs06MesrlineNetTxLaserTemp table |
| 1.3.6.1.4.1.20044.115.3.3.148.1.2 | Columnpm600frs06MesrlineNetTxLaserTempPortn | read-only | current | Current Line Trscv Tx Laser Temperature :This OID gives the Tx Laser Temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitorin… |
| 1.3.6.1.4.1.20044.115.3.3.152 | Tablepm600frs06MesrlineNetTxBiasCurrentTable | not-accessible | current | List of pm600frs06MesrlineNetTxBiasCurrent Article |
| 1.3.6.1.4.1.20044.115.3.3.152.1 | Rowpm600frs06MesrlineNetTxBiasCurrentEntry | not-accessible | current | Row definition for the pm600frs06MesrlineNetTxBiasCurrent table |
| 1.3.6.1.4.1.20044.115.3.3.152.1.1 | Columnpm600frs06MesrlineNetTxBiasCurrentIndex | read-only | current | Index definition for the pm600frs06MesrlineNetTxBiasCurrent table |
| 1.3.6.1.4.1.20044.115.3.3.152.1.2 | Columnpm600frs06MesrlineNetTxBiasCurrentPortn | read-only | current | Current Line Trscv Tx Laser Bias :This OID gives the Tx Laser Bias value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV_… |
| 1.3.6.1.4.1.20044.115.3.3.156 | Tablepm600frs06MesrlineNetRxInputPwrTable | not-accessible | current | List of pm600frs06MesrlineNetRxInputPwr Article |
| 1.3.6.1.4.1.20044.115.3.3.156.1 | Rowpm600frs06MesrlineNetRxInputPwrEntry | not-accessible | current | Row definition for the pm600frs06MesrlineNetRxInputPwr table |
| 1.3.6.1.4.1.20044.115.3.3.156.1.1 | Columnpm600frs06MesrlineNetRxInputPwrIndex | read-only | current | Index definition for the pm600frs06MesrlineNetRxInputPwr table |
| 1.3.6.1.4.1.20044.115.3.3.156.1.2 | Columnpm600frs06MesrlineNetRxInputPwrPortn | read-only | current | Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/10… |
| 1.3.6.1.4.1.20044.115.3.3.160 | Tablepm600frs06MesrlineResidualChromaticDispTable | not-accessible | current | List of pm600frs06MesrlineResidualChromaticDisp Article |
| 1.3.6.1.4.1.20044.115.3.3.160.1 | Rowpm600frs06MesrlineResidualChromaticDispEntry | not-accessible | current | Row definition for the pm600frs06MesrlineResidualChromaticDisp table |
| 1.3.6.1.4.1.20044.115.3.3.160.1.1 | Columnpm600frs06MesrlineResidualChromaticDispIndex | read-only | current | Index definition for the pm600frs06MesrlineResidualChromaticDisp table |
| 1.3.6.1.4.1.20044.115.3.3.160.1.2 | Columnpm600frs06MesrlineResidualChromaticDispPortn | read-only | current | Current Residual Chromatic Dispersion :This OID gives the current Residual Chromatic Dispersion on the Line interface (Dispersion = AV_S16) (Unit = ps/nm)<Help… |
| 1.3.6.1.4.1.20044.115.3.3.164 | Tablepm600frs06MesrlineDiffGroupDelayTable | not-accessible | current | List of pm600frs06MesrlineDiffGroupDelay Article |
| 1.3.6.1.4.1.20044.115.3.3.164.1 | Rowpm600frs06MesrlineDiffGroupDelayEntry | not-accessible | current | Row definition for the pm600frs06MesrlineDiffGroupDelay table |
| 1.3.6.1.4.1.20044.115.3.3.164.1.1 | Columnpm600frs06MesrlineDiffGroupDelayIndex | read-only | current | Index definition for the pm600frs06MesrlineDiffGroupDelay table |
| 1.3.6.1.4.1.20044.115.3.3.164.1.2 | Columnpm600frs06MesrlineDiffGroupDelayPortn | read-only | current | Current Differential Group Delay :This OID gives the current Differential Group Delay on the Line interface (Delay = AV_S16) (Unit = ps)<Help> This measure giv… |
| 1.3.6.1.4.1.20044.115.3.3.168 | Tablepm600frs06MesrlineQFactorTable | not-accessible | current | List of pm600frs06MesrlineQFactor Article |
| 1.3.6.1.4.1.20044.115.3.3.168.1 | Rowpm600frs06MesrlineQFactorEntry | not-accessible | current | Row definition for the pm600frs06MesrlineQFactor table |
| 1.3.6.1.4.1.20044.115.3.3.168.1.1 | Columnpm600frs06MesrlineQFactorIndex | read-only | current | Index definition for the pm600frs06MesrlineQFactor table |
| 1.3.6.1.4.1.20044.115.3.3.168.1.2 | Columnpm600frs06MesrlineQFactorPortn | read-only | current | Current Q Factor :This OID gives the current Q Factor on the Line interface (Q Factor = AV_U16) (Unit = dB) <Help> This measure gives the current Q Factor on t… |
| 1.3.6.1.4.1.20044.115.3.3.172 | Tablepm600frs06MesrlineCarrierFreqOffsetTable | not-accessible | current | List of pm600frs06MesrlineCarrierFreqOffset Article |
| 1.3.6.1.4.1.20044.115.3.3.172.1 | Rowpm600frs06MesrlineCarrierFreqOffsetEntry | not-accessible | current | Row definition for the pm600frs06MesrlineCarrierFreqOffset table |
| 1.3.6.1.4.1.20044.115.3.3.172.1.1 | Columnpm600frs06MesrlineCarrierFreqOffsetIndex | read-only | current | Index definition for the pm600frs06MesrlineCarrierFreqOffset table |
| 1.3.6.1.4.1.20044.115.3.3.172.1.2 | Columnpm600frs06MesrlineCarrierFreqOffsetPortn | read-only | current | Current Carrier Frequency Offset :This OID gives the current Carrier Frequency Offset on the Line interface (Offset = AV_S16) (Unit = MHz)<Help> This measure g… |
| 1.3.6.1.4.1.20044.115.3.3.176 | Tablepm600frs06MesrlineOsnrTable | not-accessible | current | List of pm600frs06MesrlineOsnr Article |
| 1.3.6.1.4.1.20044.115.3.3.176.1 | Rowpm600frs06MesrlineOsnrEntry | not-accessible | current | Row definition for the pm600frs06MesrlineOsnr table |
| 1.3.6.1.4.1.20044.115.3.3.176.1.1 | Columnpm600frs06MesrlineOsnrIndex | read-only | current | Index definition for the pm600frs06MesrlineOsnr table |
| 1.3.6.1.4.1.20044.115.3.3.176.1.2 | Columnpm600frs06MesrlineOsnrPortn | read-only | current | Current OSNR :This OID gives the current OSNR on the Line interface (OSNR = AV_S16/10) (Unit = dB)<Help> This measure gives the current OSNR on the Line interf… |
| 1.3.6.1.4.1.20044.115.3.3.492 | Scalarpm600frs06MesrlineTempMin | read-only | current | Min Line Trscv Temperature :This OID gives the minimum temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperatur… |
| 1.3.6.1.4.1.20044.115.3.3.496 | Scalarpm600frs06MesrlineTempMax | read-only | current | Max Line Trscv Temperature :This OID gives the maximum temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperatur… |
| 1.3.6.1.4.1.20044.115.4 | Nodepm600frs06counters | |||
| 1.3.6.1.4.1.20044.115.4.1 | Nodepm600frs06CntOther | |||
| 1.3.6.1.4.1.20044.115.4.2 | Nodepm600frs06CntClient | |||
| 1.3.6.1.4.1.20044.115.4.2.112 | Tablepm600frs06CntclientInputErrorCounterTable | not-accessible | current | List of pm600frs06CntclientInputErrorCounter Article |
| 1.3.6.1.4.1.20044.115.4.2.112.1 | Rowpm600frs06CntclientInputErrorCounterEntry | not-accessible | current | Row definition for the pm600frs06CntclientInputErrorCounter table |
| 1.3.6.1.4.1.20044.115.4.2.112.1.1 | Columnpm600frs06CntclientInputErrorCounterIndex | read-only | current | Index definition for the pm600frs06CntclientInputErrorCounter table |
| 1.3.6.1.4.1.20044.115.4.2.112.1.2 | Columnpm600frs06CntclientInputErrorCounterValuePortn | read-only | current | Client Input Errors :This counter gives the number of SM-BIP8 (OTU4) or 66B/64B disparities (100GbE) on client port <Help> This counter gives the number of SM-… |
| 1.3.6.1.4.1.20044.115.4.2.112.1.3 | Columnpm600frs06CntclientInputErrorCounterErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the BIP8 error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.115.4.2.112.1.4 | Columnpm600frs06CntclientInputErrorCounterOverloadPortn | read-only | current | Client Counter Overload :This OID when set indicates a BIP8 error counter overload on Port |
| 1.3.6.1.4.1.20044.115.4.2.144 | Tablepm600frs06CntclientCbipCounterTable | not-accessible | current | List of pm600frs06CntclientCbipCounter Article |
| 1.3.6.1.4.1.20044.115.4.2.144.1 | Rowpm600frs06CntclientCbipCounterEntry | not-accessible | current | Row definition for the pm600frs06CntclientCbipCounter table |
| 1.3.6.1.4.1.20044.115.4.2.144.1.1 | Columnpm600frs06CntclientCbipCounterIndex | read-only | current | Index definition for the pm600frs06CntclientCbipCounter table |
| 1.3.6.1.4.1.20044.115.4.2.144.1.2 | Columnpm600frs06CntclientCbipCounterValuePortn | read-only | current | Client Output Errors :This counter gives the number of SM-BIP8 (OTU4) or 66B/64B disparities (100GbE) on client port <Help> This counter gives the number of SM… |
| 1.3.6.1.4.1.20044.115.4.2.144.1.3 | Columnpm600frs06CntclientCbipCounterErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the BIP8 error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.115.4.2.144.1.4 | Columnpm600frs06CntclientCbipCounterOverloadPortn | read-only | current | Client CBIP Counter Overload :This OID when set indicates a BIP8 error counter overload on Port |
| 1.3.6.1.4.1.20044.115.4.3 | Nodepm600frs06CntLine | |||
| 1.3.6.1.4.1.20044.115.4.3.192 | Tablepm600frs06CntlocalLineSmBip8ErrorCounterTable | not-accessible | current | List of pm600frs06CntlocalLineSmBip8ErrorCounter Article |
| 1.3.6.1.4.1.20044.115.4.3.192.1 | Rowpm600frs06CntlocalLineSmBip8ErrorCounterEntry | not-accessible | current | Row definition for the pm600frs06CntlocalLineSmBip8ErrorCounter table |
| 1.3.6.1.4.1.20044.115.4.3.192.1.1 | Columnpm600frs06CntlocalLineSmBip8ErrorCounterIndex | read-only | current | Index definition for the pm600frs06CntlocalLineSmBip8ErrorCounter table |
| 1.3.6.1.4.1.20044.115.4.3.192.1.2 | Columnpm600frs06CntlocalLineSmBip8ErrorCounterValuePortn | read-only | current | Uncorrected FEC Errors :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC <Help> This counter gives the current Bit Error Rate (resi… |
| 1.3.6.1.4.1.20044.115.4.3.192.1.3 | Columnpm600frs06CntlocalLineSmBip8ErrorCounterErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the B1 error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.115.4.3.192.1.4 | Columnpm600frs06CntlocalLineSmBip8ErrorCounterOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a B1 error counter overload on Port |
| 1.3.6.1.4.1.20044.115.4.3.193 | Tablepm600frs06CntlocalLineFecCorrectedErrorsCounterTable | not-accessible | current | List of pm600frs06CntlocalLineFecCorrectedErrorsCounter Article |
| 1.3.6.1.4.1.20044.115.4.3.193.1 | Rowpm600frs06CntlocalLineFecCorrectedErrorsCounterEntry | not-accessible | current | Row definition for the pm600frs06CntlocalLineFecCorrectedErrorsCounter table |
| 1.3.6.1.4.1.20044.115.4.3.193.1.1 | Columnpm600frs06CntlocalLineFecCorrectedErrorsCounterIndex | read-only | current | Index definition for the pm600frs06CntlocalLineFecCorrectedErrorsCounter table |
| 1.3.6.1.4.1.20044.115.4.3.193.1.2 | Columnpm600frs06CntlocalLineFecCorrectedErrorsCounterValuePortn | read-only | current | Line Input HD FEC Corrected Errors :This OID gives the current Bit Error Rate before the Hard Decision FEC <Help> This counter gives the current Bit Error Rate… |
| 1.3.6.1.4.1.20044.115.4.3.193.1.3 | Columnpm600frs06CntlocalLineFecCorrectedErrorsCounterErrorPortn | read-only | current | FEC Counter Error :This bit when set indicates the FEC corrected errors counter value is invalid on Line |
| 1.3.6.1.4.1.20044.115.4.3.193.1.4 | Columnpm600frs06CntlocalLineFecCorrectedErrorsCounterOverloadPortn | read-only | current | FEC Counter Overload :This bit when set indicates a FEC corrected errors counter overload on Line |
| 1.3.6.1.4.1.20044.115.4.3.194 | Tablepm600frs06CntremoteLineSmBip8ErrorCounterTable | not-accessible | current | List of pm600frs06CntremoteLineSmBip8ErrorCounter Article |
| 1.3.6.1.4.1.20044.115.4.3.194.1 | Rowpm600frs06CntremoteLineSmBip8ErrorCounterEntry | not-accessible | current | Row definition for the pm600frs06CntremoteLineSmBip8ErrorCounter table |
| 1.3.6.1.4.1.20044.115.4.3.194.1.1 | Columnpm600frs06CntremoteLineSmBip8ErrorCounterIndex | read-only | current | Index definition for the pm600frs06CntremoteLineSmBip8ErrorCounter table |
| 1.3.6.1.4.1.20044.115.4.3.194.1.2 | Columnpm600frs06CntremoteLineSmBip8ErrorCounterValuePortn | read-only | current | Remote SM BIP8 :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC on the remote side <Help> This counter gives the current Bit Error… |
| 1.3.6.1.4.1.20044.115.4.3.194.1.3 | Columnpm600frs06CntremoteLineSmBip8ErrorCounterErrorPortn | read-only | current | Remote Counter Error : |
| 1.3.6.1.4.1.20044.115.4.3.194.1.4 | Columnpm600frs06CntremoteLineSmBip8ErrorCounterOverloadPortn | read-only | current | Remote Counter Overload : |
| 1.3.6.1.4.1.20044.115.4.3.195 | Tablepm600frs06CntlineDfrmTimCntTable | not-accessible | current | List of pm600frs06CntlineDfrmTimCnt Article |
| 1.3.6.1.4.1.20044.115.4.3.195.1 | Rowpm600frs06CntlineDfrmTimCntEntry | not-accessible | current | Row definition for the pm600frs06CntlineDfrmTimCnt table |
| 1.3.6.1.4.1.20044.115.4.3.195.1.1 | Columnpm600frs06CntlineDfrmTimCntIndex | read-only | current | Index definition for the pm600frs06CntlineDfrmTimCnt table |
| 1.3.6.1.4.1.20044.115.4.3.195.1.2 | Columnpm600frs06CntlineDfrmTimCntValuePortn | read-only | current | Line Timer Counter : |
| 1.3.6.1.4.1.20044.115.4.3.195.1.3 | Columnpm600frs06CntlineDfrmTimCntErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.115.4.3.195.1.4 | Columnpm600frs06CntlineDfrmTimCntOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.115.4.3.196 | Tablepm600frs06CntlocalLineTrscvPreSdFecErrorCounterTable | not-accessible | current | List of pm600frs06CntlocalLineTrscvPreSdFecErrorCounter Article |
| 1.3.6.1.4.1.20044.115.4.3.196.1 | Rowpm600frs06CntlocalLineTrscvPreSdFecErrorCounterEntry | not-accessible | current | Row definition for the pm600frs06CntlocalLineTrscvPreSdFecErrorCounter table |
| 1.3.6.1.4.1.20044.115.4.3.196.1.1 | Columnpm600frs06CntlocalLineTrscvPreSdFecErrorCounterIndex | read-only | current | Index definition for the pm600frs06CntlocalLineTrscvPreSdFecErrorCounter table |
| 1.3.6.1.4.1.20044.115.4.3.196.1.2 | Columnpm600frs06CntlocalLineTrscvPreSdFecErrorCounterValuePortn | read-only | current | Pre FEC Errors :This OID gives the current Bit Error Rate before the FEC <Help> This counter gives the current Bit Error Rate before the FEC |
| 1.3.6.1.4.1.20044.115.4.3.196.1.3 | Columnpm600frs06CntlocalLineTrscvPreSdFecErrorCounterErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.115.4.3.196.1.4 | Columnpm600frs06CntlocalLineTrscvPreSdFecErrorCounterOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.115.4.3.197 | Tablepm600frs06CntlocalLineTrscvUncorrectedSdFecErrorCounterTable | not-accessible | current | List of pm600frs06CntlocalLineTrscvUncorrectedSdFecErrorCounter Article |
| 1.3.6.1.4.1.20044.115.4.3.197.1 | Rowpm600frs06CntlocalLineTrscvUncorrectedSdFecErrorCounterEntry | not-accessible | current | Row definition for the pm600frs06CntlocalLineTrscvUncorrectedSdFecErrorCounter table |
| 1.3.6.1.4.1.20044.115.4.3.197.1.1 | Columnpm600frs06CntlocalLineTrscvUncorrectedSdFecErrorCounterIndex | read-only | current | Index definition for the pm600frs06CntlocalLineTrscvUncorrectedSdFecErrorCounter table |
| 1.3.6.1.4.1.20044.115.4.3.197.1.2 | Columnpm600frs06CntlocalLineTrscvUncorrectedSdFecErrorCounterValuePortn | read-only | current | Uncorrected FEC Errors :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC <Help> This counter gives the current Bit Error Rate (resi… |
| 1.3.6.1.4.1.20044.115.4.3.197.1.3 | Columnpm600frs06CntlocalLineTrscvUncorrectedSdFecErrorCounterErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.115.4.3.197.1.4 | Columnpm600frs06CntlocalLineTrscvUncorrectedSdFecErrorCounterOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.115.4.3.198 | Tablepm600frs06CntlocalLineTrscvPreSdFecBitCounterTable | not-accessible | current | List of pm600frs06CntlocalLineTrscvPreSdFecBitCounter Article |
| 1.3.6.1.4.1.20044.115.4.3.198.1 | Rowpm600frs06CntlocalLineTrscvPreSdFecBitCounterEntry | not-accessible | current | Row definition for the pm600frs06CntlocalLineTrscvPreSdFecBitCounter table |
| 1.3.6.1.4.1.20044.115.4.3.198.1.1 | Columnpm600frs06CntlocalLineTrscvPreSdFecBitCounterIndex | read-only | current | Index definition for the pm600frs06CntlocalLineTrscvPreSdFecBitCounter table |
| 1.3.6.1.4.1.20044.115.4.3.198.1.2 | Columnpm600frs06CntlocalLineTrscvPreSdFecBitCounterValuePortn | read-only | current | Pre-SD FEC Bit Counter :This OID gives the current Bit count before the Soft Decision FEC <Help> This counter gives the current Bit Count before the Soft Decis… |
| 1.3.6.1.4.1.20044.115.4.3.198.1.3 | Columnpm600frs06CntlocalLineTrscvPreSdFecBitCounterErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.115.4.3.198.1.4 | Columnpm600frs06CntlocalLineTrscvPreSdFecBitCounterOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.115.4.3.199 | Tablepm600frs06CntlocalLineTrscvUncorrectedSdFecBitCounterTable | not-accessible | current | List of pm600frs06CntlocalLineTrscvUncorrectedSdFecBitCounter Article |
| 1.3.6.1.4.1.20044.115.4.3.199.1 | Rowpm600frs06CntlocalLineTrscvUncorrectedSdFecBitCounterEntry | not-accessible | current | Row definition for the pm600frs06CntlocalLineTrscvUncorrectedSdFecBitCounter table |
| 1.3.6.1.4.1.20044.115.4.3.199.1.1 | Columnpm600frs06CntlocalLineTrscvUncorrectedSdFecBitCounterIndex | read-only | current | Index definition for the pm600frs06CntlocalLineTrscvUncorrectedSdFecBitCounter table |
| 1.3.6.1.4.1.20044.115.4.3.199.1.2 | Columnpm600frs06CntlocalLineTrscvUncorrectedSdFecBitCounterValuePortn | read-only | current | Uncorrected SD FEC Bit Counter :This OID gives the current Bit count after the Soft Decision FEC (residual) <Help> This counter gives the current Bit Count aft… |
| 1.3.6.1.4.1.20044.115.4.3.199.1.3 | Columnpm600frs06CntlocalLineTrscvUncorrectedSdFecBitCounterErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.115.4.3.199.1.4 | Columnpm600frs06CntlocalLineTrscvUncorrectedSdFecBitCounterOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.115.6 | Nodepm600frs06controlsWrite | |||
| 1.3.6.1.4.1.20044.115.6.1 | Nodepm600frs06CtrlOther | |||
| 1.3.6.1.4.1.20044.115.6.1.1 | Nodepm600frs06CtrlconfMgnt1 | |||
| 1.3.6.1.4.1.20044.115.6.1.1.1 | Scalarpm600frs06CtrlConf1Load1 | read-write | current | Load Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM. |
| 1.3.6.1.4.1.20044.115.6.1.1.2 | Scalarpm600frs06CtrlConf2Load1 | read-write | current | Load Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM. |
| 1.3.6.1.4.1.20044.115.6.1.1.10 | Scalarpm600frs06CtrlConf2Flash1 | read-write | current | Write Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura… |
| 1.3.6.1.4.1.20044.115.6.1.1.14 | Scalarpm600frs06CtrlConf2Clear1 | read-write | current | Clear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o… |
| 1.3.6.1.4.1.20044.115.6.1.4 | Nodepm600frs06Ctrlsynth4 | |||
| 1.3.6.1.4.1.20044.115.6.1.4.1 | Scalarpm600frs06CtrlCorrelatOn | read-write | current | Enable Alarm Correlation :This OID enables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.115.6.1.4.2 | Scalarpm600frs06CtrlCorrelatOff | read-write | current | Disable Alarm Correlation :This OID disables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.115.6.1.5 | Nodepm600frs06CtrlswMgnt | |||
| 1.3.6.1.4.1.20044.115.6.1.5.2 | Scalarpm600frs06CtrlColdReset | read-write | current | PM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> … |
| 1.3.6.1.4.1.20044.115.6.1.5.3 | Scalarpm600frs06CtrlWarmReset | read-write | current | PM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th… |
| 1.3.6.1.4.1.20044.115.6.1.5.5 | Scalarpm600frs06CtrlLoadSwBank1 | read-write | current | Set Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW… |
| 1.3.6.1.4.1.20044.115.6.1.5.6 | Scalarpm600frs06CtrlLoadSwBank2 | read-write | current | Set Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S… |
| 1.3.6.1.4.1.20044.115.6.1.6 | Nodepm600frs06CtrlgwMgnt | |||
| 1.3.6.1.4.1.20044.115.6.1.6.1 | Scalarpm600frs06CtrlCurrentGwReset | read-write | current | Active Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting. |
| 1.3.6.1.4.1.20044.115.6.1.6.5 | Scalarpm600frs06CtrlLoadGwBank1 | read-write | current | Set Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.115.6.1.6.6 | Scalarpm600frs06CtrlLoadGwBank2 | read-write | current | Set Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.115.6.1.6.7 | Scalarpm600frs06CtrlLoadGwBank3 | read-write | current | Set Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.115.6.1.6.8 | Scalarpm600frs06CtrlLoadGwBank4 | read-write | current | Set Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.115.6.1.192 | Nodepm600frs06CtrlledTest | |||
| 1.3.6.1.4.1.20044.115.6.1.192.1 | Scalarpm600frs06CtrlGreenLed | read-write | current | Green Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green |
| 1.3.6.1.4.1.20044.115.6.1.192.2 | Scalarpm600frs06CtrlRedLed | read-write | current | Red Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red |
| 1.3.6.1.4.1.20044.115.6.1.192.3 | Scalarpm600frs06CtrlLedOff | read-write | current | Leds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF |
| 1.3.6.1.4.1.20044.115.6.1.201 | Nodepm600frs06CtrlinitSwitchMarvell | |||
| 1.3.6.1.4.1.20044.115.6.1.201.1 | Scalarpm600frs06CtrlInitSwitchMarvell | read-write | current | Switch Initialization :This OID operates an initialization of the switch managed through the module <Help> This control activates an initialization of the swit… |
| 1.3.6.1.4.1.20044.115.6.1.259 | Nodepm600frs06CtrlresetCount | |||
| 1.3.6.1.4.1.20044.115.6.1.259.1 | Scalarpm600frs06CtrlResetcount | read-write | current | Module Count Global Reset :This OID resets all the errors counters on the module <Help > This control initiates a reset of the errors counters on the module |
| 1.3.6.1.4.1.20044.115.6.1.260 | Nodepm600frs06CtrlresetRmon | |||
| 1.3.6.1.4.1.20044.115.6.1.260.1 | Scalarpm600frs06CtrlResetrmon | read-write | current | Module Rmon Global Reset :This OID resets all the Rmon counters on the module <Help > This control initiates a reset of the Rmon counters on the module |
| 1.3.6.1.4.1.20044.115.6.1.261 | Nodepm600frs06CtrlresetMeasurements | |||
| 1.3.6.1.4.1.20044.115.6.1.261.1 | Scalarpm600frs06CtrlResetmeasurements | read-write | current | Management Meas Global Reset :This OID resets some measurements on the management <Help > This control initiates a reset of some measurements on the management |
| 1.3.6.1.4.1.20044.115.6.2 | Nodepm600frs06CtrlClient | |||
| 1.3.6.1.4.1.20044.115.6.2.16 | Tablepm600frs06CtrlaccessLoopTable | not-accessible | current | List of pm600frs06CtrlaccessLoop Article |
| 1.3.6.1.4.1.20044.115.6.2.16.1 | Rowpm600frs06CtrlaccessLoopEntry | not-accessible | current | Row definition for the pm600frs06CtrlaccessLoop table |
| 1.3.6.1.4.1.20044.115.6.2.16.1.1 | Columnpm600frs06CtrlaccessLoopIndex | read-only | current | Index definition for the pm600frs06CtrlaccessLoop table |
| 1.3.6.1.4.1.20044.115.6.2.16.1.2 | Columnpm600frs06CtrlaccessLoopPortn | read-write | current | Client Facility Loopback :This OID, when set at '1' puts the client port in loopback, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. <Help… |
| 1.3.6.1.4.1.20044.115.6.2.17 | Tablepm600frs06CtrlclientLoopToLineTable | not-accessible | current | List of pm600frs06CtrlclientLoopToLine Article |
| 1.3.6.1.4.1.20044.115.6.2.17.1 | Rowpm600frs06CtrlclientLoopToLineEntry | not-accessible | current | Row definition for the pm600frs06CtrlclientLoopToLine table |
| 1.3.6.1.4.1.20044.115.6.2.17.1.1 | Columnpm600frs06CtrlclientLoopToLineIndex | read-only | current | Index definition for the pm600frs06CtrlclientLoopToLine table |
| 1.3.6.1.4.1.20044.115.6.2.17.1.2 | Columnpm600frs06CtrlclientLoopToLinePortn | read-write | current | Client Terminal Loopback :This OID, when set, puts the client port in loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.<Help> This control ena… |
| 1.3.6.1.4.1.20044.115.6.2.21 | Tablepm600frs06CtrlcsfUpInsTable | not-accessible | current | List of pm600frs06CtrlcsfUpIns Article |
| 1.3.6.1.4.1.20044.115.6.2.21.1 | Rowpm600frs06CtrlcsfUpInsEntry | not-accessible | current | Row definition for the pm600frs06CtrlcsfUpIns table |
| 1.3.6.1.4.1.20044.115.6.2.21.1.1 | Columnpm600frs06CtrlcsfUpInsIndex | read-only | current | Index definition for the pm600frs06CtrlcsfUpIns table |
| 1.3.6.1.4.1.20044.115.6.2.21.1.2 | Columnpm600frs06CtrlcsfUpInsPortn | read-write | current | Client Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo… |
| 1.3.6.1.4.1.20044.115.6.2.22 | Tablepm600frs06CtrlcaisDwInsTable | not-accessible | current | List of pm600frs06CtrlcaisDwIns Article |
| 1.3.6.1.4.1.20044.115.6.2.22.1 | Rowpm600frs06CtrlcaisDwInsEntry | not-accessible | current | Row definition for the pm600frs06CtrlcaisDwIns table |
| 1.3.6.1.4.1.20044.115.6.2.22.1.1 | Columnpm600frs06CtrlcaisDwInsIndex | read-only | current | Index definition for the pm600frs06CtrlcaisDwIns table |
| 1.3.6.1.4.1.20044.115.6.2.22.1.2 | Columnpm600frs06CtrlcaisDwInsPortn | read-write | current | Client AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port |
| 1.3.6.1.4.1.20044.115.6.2.23 | Tablepm600frs06CtrlbistInsertTrafficTestTable | not-accessible | current | List of pm600frs06CtrlbistInsertTrafficTest Article |
| 1.3.6.1.4.1.20044.115.6.2.23.1 | Rowpm600frs06CtrlbistInsertTrafficTestEntry | not-accessible | current | Row definition for the pm600frs06CtrlbistInsertTrafficTest table |
| 1.3.6.1.4.1.20044.115.6.2.23.1.1 | Columnpm600frs06CtrlbistInsertTrafficTestIndex | read-only | current | Index definition for the pm600frs06CtrlbistInsertTrafficTest table |
| 1.3.6.1.4.1.20044.115.6.2.23.1.2 | Columnpm600frs06CtrlbistInsertTrafficTestPortn | read-write | current | BIST Insert Test Traffic :This OID initiates the Built-In Self Test test traffic insertion <Help> This parameter initiates the Built-In Self Test test traffic … |
| 1.3.6.1.4.1.20044.115.6.2.24 | Tablepm600frs06CtrlbistResetTestTable | not-accessible | current | List of pm600frs06CtrlbistResetTest Article |
| 1.3.6.1.4.1.20044.115.6.2.24.1 | Rowpm600frs06CtrlbistResetTestEntry | not-accessible | current | Row definition for the pm600frs06CtrlbistResetTest table |
| 1.3.6.1.4.1.20044.115.6.2.24.1.1 | Columnpm600frs06CtrlbistResetTestIndex | read-only | current | Index definition for the pm600frs06CtrlbistResetTest table |
| 1.3.6.1.4.1.20044.115.6.2.24.1.2 | Columnpm600frs06CtrlbistResetPortn | read-write | current | BIST Reset :This OID resets the BIST Result alarm to OFF <Help> This parameter resets the BIST Result alarm to OFF |
| 1.3.6.1.4.1.20044.115.6.2.36 | Tablepm600frs06CtrlbistModeTestTable | not-accessible | current | List of pm600frs06CtrlbistModeTest Article |
| 1.3.6.1.4.1.20044.115.6.2.36.1 | Rowpm600frs06CtrlbistModeTestEntry | not-accessible | current | Row definition for the pm600frs06CtrlbistModeTest table |
| 1.3.6.1.4.1.20044.115.6.2.36.1.1 | Columnpm600frs06CtrlbistModeTestIndex | read-only | current | Index definition for the pm600frs06CtrlbistModeTest table |
| 1.3.6.1.4.1.20044.115.6.2.36.1.2 | Columnpm600frs06CtrlbistModeTestPortn | read-write | current | BIST Mode :This OID enables the Built-In Self Test mode on the client port <Help> This parameter enables the Built-In Self Test mode on the client port |
| 1.3.6.1.4.1.20044.115.6.2.262 | Tablepm600frs06CtrlclientResetAllCountTable | not-accessible | current | List of pm600frs06CtrlclientResetAllCount Article |
| 1.3.6.1.4.1.20044.115.6.2.262.1 | Rowpm600frs06CtrlclientResetAllCountEntry | not-accessible | current | Row definition for the pm600frs06CtrlclientResetAllCount table |
| 1.3.6.1.4.1.20044.115.6.2.262.1.1 | Columnpm600frs06CtrlclientResetAllCountIndex | read-only | current | Index definition for the pm600frs06CtrlclientResetAllCount table |
| 1.3.6.1.4.1.20044.115.6.2.262.1.2 | Columnpm600frs06CtrlclientResetAllCountsPortn | read-write | current | Client Counters Reset :This OID resets every counter on the client port <Help> This control operates a reset on the statistics current ,previous and history cl… |
| 1.3.6.1.4.1.20044.115.6.3 | Nodepm600frs06CtrlLine | |||
| 1.3.6.1.4.1.20044.115.6.3.64 | Tablepm600frs06CtrlcommAccessLoopTable | not-accessible | current | List of pm600frs06CtrlcommAccessLoop Article |
| 1.3.6.1.4.1.20044.115.6.3.64.1 | Rowpm600frs06CtrlcommAccessLoopEntry | not-accessible | current | Row definition for the pm600frs06CtrlcommAccessLoop table |
| 1.3.6.1.4.1.20044.115.6.3.64.1.1 | Columnpm600frs06CtrlcommAccessLoopIndex | read-only | current | Index definition for the pm600frs06CtrlcommAccessLoop table |
| 1.3.6.1.4.1.20044.115.6.3.64.1.2 | Columnpm600frs06CtrlcommAccessLoopPortn | read-write | current | Line Terminal Loopback :This OID, when set, puts the module in common access loop back, looping the 200 Gb/s output signal on the 200 Gb/s input.<Help> This co… |
| 1.3.6.1.4.1.20044.115.6.3.66 | Tablepm600frs06CtrllineLoopTable | not-accessible | current | List of pm600frs06CtrllineLoop Article |
| 1.3.6.1.4.1.20044.115.6.3.66.1 | Rowpm600frs06CtrllineLoopEntry | not-accessible | current | Row definition for the pm600frs06CtrllineLoop table |
| 1.3.6.1.4.1.20044.115.6.3.66.1.1 | Columnpm600frs06CtrllineLoopIndex | read-only | current | Index definition for the pm600frs06CtrllineLoop table |
| 1.3.6.1.4.1.20044.115.6.3.66.1.2 | Columnpm600frs06CtrllineLoopPortn | read-write | current | Line Facility Loopback :This OID, when set at '1' puts the module in line loopback mode, looping the received 200 Gb/s signal on the transmit 200 Gb/s output. … |
| 1.3.6.1.4.1.20044.115.6.3.69 | Tablepm600frs06CtrlfecDisableTable | not-accessible | current | List of pm600frs06CtrlfecDisable Article |
| 1.3.6.1.4.1.20044.115.6.3.69.1 | Rowpm600frs06CtrlfecDisableEntry | not-accessible | current | Row definition for the pm600frs06CtrlfecDisable table |
| 1.3.6.1.4.1.20044.115.6.3.69.1.1 | Columnpm600frs06CtrlfecDisableIndex | read-only | current | Index definition for the pm600frs06CtrlfecDisable table |
| 1.3.6.1.4.1.20044.115.6.3.69.1.2 | Columnpm600frs06CtrlfecDisablePortn | read-write | current | Forward Error Correction Inhibition :This OID, when set, inhibits the Forward Error Correction feature on the line input <Help> This control enables/disables t… |
| 1.3.6.1.4.1.20044.115.6.3.209 | Tablepm600frs06CtrlmsaLineLoopTable | not-accessible | current | List of pm600frs06CtrlmsaLineLoop Article |
| 1.3.6.1.4.1.20044.115.6.3.209.1 | Rowpm600frs06CtrlmsaLineLoopEntry | not-accessible | current | Row definition for the pm600frs06CtrlmsaLineLoop table |
| 1.3.6.1.4.1.20044.115.6.3.209.1.1 | Columnpm600frs06CtrlmsaLineLoopIndex | read-only | current | Index definition for the pm600frs06CtrlmsaLineLoop table |
| 1.3.6.1.4.1.20044.115.6.3.209.1.2 | Columnpm600frs06CtrlmsaLineLoopPortn | read-write | current | MSA Line Loop :This OID operates a line loopback on the MSA Line <Help> This control defines the line loop back of the line transceiver |
| 1.3.6.1.4.1.20044.115.6.3.210 | Tablepm600frs06CtrlcoherentLineResyncTable | not-accessible | current | List of pm600frs06CtrlcoherentLineResync Article |
| 1.3.6.1.4.1.20044.115.6.3.210.1 | Rowpm600frs06CtrlcoherentLineResyncEntry | not-accessible | current | Row definition for the pm600frs06CtrlcoherentLineResync table |
| 1.3.6.1.4.1.20044.115.6.3.210.1.1 | Columnpm600frs06CtrlcoherentLineResyncIndex | read-only | current | Index definition for the pm600frs06CtrlcoherentLineResync table |
| 1.3.6.1.4.1.20044.115.6.3.210.1.2 | Columnpm600frs06CtrlcoherentLineResyncPortn | read-write | current | Coherent Line Resync :This parameter forces the resynchronization of the Coherent Line interface. <Help> This maintenance parameter forces the resynchronizatio… |
| 1.3.6.1.4.1.20044.115.6.3.211 | Tablepm600frs06CtrlberOptimizationTable | not-accessible | current | List of pm600frs06CtrlberOptimization Article |
| 1.3.6.1.4.1.20044.115.6.3.211.1 | Rowpm600frs06CtrlberOptimizationEntry | not-accessible | current | Row definition for the pm600frs06CtrlberOptimization table |
| 1.3.6.1.4.1.20044.115.6.3.211.1.1 | Columnpm600frs06CtrlberOptimizationIndex | read-only | current | Index definition for the pm600frs06CtrlberOptimization table |
| 1.3.6.1.4.1.20044.115.6.3.211.1.2 | Columnpm600frs06CtrlberOptimizationPortn | read-write | current | Ber Optimization :This OID, when enabled, initiates the BER optimization process which can last up to 10 seconds. <Help> This maintenance parameter initiate th… |
| 1.3.6.1.4.1.20044.115.6.3.213 | Tablepm600frs06CtrlforceLineRestartTable | not-accessible | current | List of pm600frs06CtrlforceLineRestart Article |
| 1.3.6.1.4.1.20044.115.6.3.213.1 | Rowpm600frs06CtrlforceLineRestartEntry | not-accessible | current | Row definition for the pm600frs06CtrlforceLineRestart table |
| 1.3.6.1.4.1.20044.115.6.3.213.1.1 | Columnpm600frs06CtrlforceLineRestartIndex | read-only | current | Index definition for the pm600frs06CtrlforceLineRestart table |
| 1.3.6.1.4.1.20044.115.6.3.213.1.2 | Columnpm600frs06CtrlforceLineRestartPortn | read-write | current | Force Line Restart :This OID forces the restart of the line after a temperature shutdown<Help> This maintenance parameter initiates the restart of the line aft… |
| 1.3.6.1.4.1.20044.115.6.3.221 | Tablepm600frs06CtrlforceKeyExchangeTable | not-accessible | deprecated | List of pm600frs06CtrlforceKeyExchange Article |
| 1.3.6.1.4.1.20044.115.6.3.221.1 | Rowpm600frs06CtrlforceKeyExchangeEntry | not-accessible | deprecated | Row definition for the pm600frs06CtrlforceKeyExchange table |
| 1.3.6.1.4.1.20044.115.6.3.221.1.1 | Columnpm600frs06CtrlforceKeyExchangeIndex | read-only | deprecated | Index definition for the pm600frs06CtrlforceKeyExchange table |
| 1.3.6.1.4.1.20044.115.6.3.221.1.2 | Columnpm600frs06CtrlforceKeyExchangePortn | read-write | deprecated | : |
| 1.3.6.1.4.1.20044.115.6.3.222 | Tablepm600frs06CtrldisableEncryptionTable | not-accessible | deprecated | List of pm600frs06CtrldisableEncryption Article |
| 1.3.6.1.4.1.20044.115.6.3.222.1 | Rowpm600frs06CtrldisableEncryptionEntry | not-accessible | deprecated | Row definition for the pm600frs06CtrldisableEncryption table |
| 1.3.6.1.4.1.20044.115.6.3.222.1.1 | Columnpm600frs06CtrldisableEncryptionIndex | read-only | deprecated | Index definition for the pm600frs06CtrldisableEncryption table |
| 1.3.6.1.4.1.20044.115.6.3.222.1.2 | Columnpm600frs06CtrldisableEncryptionPortn | read-write | deprecated | : |
| 1.3.6.1.4.1.20044.115.6.3.223 | Tablepm600frs06CtrlresetMonitoringTable | not-accessible | deprecated | List of pm600frs06CtrlresetMonitoring Article |
| 1.3.6.1.4.1.20044.115.6.3.223.1 | Rowpm600frs06CtrlresetMonitoringEntry | not-accessible | deprecated | Row definition for the pm600frs06CtrlresetMonitoring table |
| 1.3.6.1.4.1.20044.115.6.3.223.1.1 | Columnpm600frs06CtrlresetMonitoringIndex | read-only | deprecated | Index definition for the pm600frs06CtrlresetMonitoring table |
| 1.3.6.1.4.1.20044.115.6.3.223.1.2 | Columnpm600frs06CtrlresetMonitoringPortn | read-write | deprecated | : |
| 1.3.6.1.4.1.20044.115.6.3.263 | Tablepm600frs06CtrllineResetAllCountTable | not-accessible | current | List of pm600frs06CtrllineResetAllCount Article |
| 1.3.6.1.4.1.20044.115.6.3.263.1 | Rowpm600frs06CtrllineResetAllCountEntry | not-accessible | current | Row definition for the pm600frs06CtrllineResetAllCount table |
| 1.3.6.1.4.1.20044.115.6.3.263.1.1 | Columnpm600frs06CtrllineResetAllCountIndex | read-only | current | Index definition for the pm600frs06CtrllineResetAllCount table |
| 1.3.6.1.4.1.20044.115.6.3.263.1.2 | Columnpm600frs06CtrllineResetAllCountsPortn | read-write | current | Line Counters Reset :This OID resets every counter on the line port <Help> This control operates a reset on the statistics current ,previous and history line p… |
| 1.3.6.1.4.1.20044.115.7 | Nodepm600frs06ri | |||
| 1.3.6.1.4.1.20044.115.7.1 | Nodepm600frs06riTable | |||
| 1.3.6.1.4.1.20044.115.7.1.1 | Tablepm600frs06RinvSfpTable | not-accessible | current | List of the SFPs on the selected module |
| 1.3.6.1.4.1.20044.115.7.1.1.1 | Rowpm600frs06RinvSfpEntry | not-accessible | current | Row definition for the SFP table |
| 1.3.6.1.4.1.20044.115.7.1.1.1.1 | Columnpm600frs06RinvSfpIndex | read-only | current | Index for SFP table |
| 1.3.6.1.4.1.20044.115.7.1.1.1.2 | Columnpm600frs06Rinvsfp | read-only | current | Inventory for the SFP: This OID contains the inventory for the SFP |
| 1.3.6.1.4.1.20044.115.7.1.2 | Tablepm600frs06RinvLineTable | not-accessible | current | List of the XFPs on the selected module |
| 1.3.6.1.4.1.20044.115.7.1.2.1 | Rowpm600frs06RinvLineEntry | not-accessible | current | Row definition for the XFP table |
| 1.3.6.1.4.1.20044.115.7.1.2.1.1 | Columnpm600frs06RinvLineIndex | read-only | current | Index for XFP table |
| 1.3.6.1.4.1.20044.115.7.1.2.1.2 | Columnpm600frs06RinvxfpLine | read-only | current | Inventory for the XFP: This OID contains the inventory for the XFP |
| 1.3.6.1.4.1.20044.115.7.2 | Scalarpm600frs06RinvReloadInventory | read-write | current | Reload the inventory: This OID triggers an inventory reload. |
| 1.3.6.1.4.1.20044.115.7.3 | Scalarpm600frs06RinvHwPlatform | read-only | current | HW platform description: This OID contains the description of the Hardware platform. |
| 1.3.6.1.4.1.20044.115.7.4 | Scalarpm600frs06RinvModulePlatform | read-only | current | Module platform description: This OID contains the description of the Module. |
| 1.3.6.1.4.1.20044.115.7.5 | Scalarpm600frs06RinvSwPlatform | read-only | current | SW platform description: This OID contains the description of the Software platform. |
| 1.3.6.1.4.1.20044.115.7.6 | Scalarpm600frs06RinvGwPlatform | read-only | current | GW platform description: This OID contains the description of the Gateware platform. |
| 1.3.6.1.4.1.20044.115.8 | Nodepm600frs06download | |||
| 1.3.6.1.4.1.20044.115.8.1 | Nodepm600frs06DwlOther | |||
| 1.3.6.1.4.1.20044.115.8.1.0 | Nodepm600frs06DwlrestartProcess | |||
| 1.3.6.1.4.1.20044.115.8.1.0.1 | Scalarpm600frs06DwlWarmRestartProcessed | read-only | current | Warm Restart :This OID indicates that the module last restart was a Warm RESTART |
| 1.3.6.1.4.1.20044.115.8.1.0.2 | Scalarpm600frs06DwlColdRestartProcessed | read-only | current | Cold Restart :This OID indicates that the module last restart was a Cold RESTART |
| 1.3.6.1.4.1.20044.115.8.1.1 | Nodepm600frs06DwlswBanksUsed | |||
| 1.3.6.1.4.1.20044.115.8.1.1.1 | Scalarpm600frs06DwlSwBank1Used | read-only | current | SW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.115.8.1.1.2 | Scalarpm600frs06DwlSwBank2Used | read-only | current | SW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby |
| 1.3.6.1.4.1.20044.115.8.1.1.5 | Scalarpm600frs06DwlSwBank1Notempty | read-only | current | SW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package |
| 1.3.6.1.4.1.20044.115.8.1.1.6 | Scalarpm600frs06DwlSwBank2Notempty | read-only | current | SW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package |
| 1.3.6.1.4.1.20044.115.8.1.2 | Nodepm600frs06DwlgwBanksUsed | |||
| 1.3.6.1.4.1.20044.115.8.1.2.1 | Scalarpm600frs06DwlGwBank1Used | read-only | current | GW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.115.8.1.2.2 | Scalarpm600frs06DwlGwBank2Used | read-only | current | GW bank 2 active :This OID indicates the module is working on GW bank 2 |
| 1.3.6.1.4.1.20044.115.8.1.2.3 | Scalarpm600frs06DwlGwBank3Used | read-only | current | GW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby |
| 1.3.6.1.4.1.20044.115.8.1.2.4 | Scalarpm600frs06DwlGwBank4Used | read-only | current | GW bank 4 active :This OID indicates the module is working on GW bank 4 |
| 1.3.6.1.4.1.20044.115.8.1.2.5 | Scalarpm600frs06DwlGwBank1Notempty | read-only | current | GW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package |
| 1.3.6.1.4.1.20044.115.8.1.2.6 | Scalarpm600frs06DwlGwBank2Notempty | read-only | current | GW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2 |
| 1.3.6.1.4.1.20044.115.8.1.2.7 | Scalarpm600frs06DwlGwBank3Notempty | read-only | current | GW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package |
| 1.3.6.1.4.1.20044.115.8.1.2.8 | Scalarpm600frs06DwlGwBank4Notempty | read-only | current | GW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4 |
| 1.3.6.1.4.1.20044.115.8.2 | Nodepm600frs06DwlClient | |||
| 1.3.6.1.4.1.20044.115.8.3 | Nodepm600frs06DwlLine | |||
| 1.3.6.1.4.1.20044.115.9 | Nodepm600frs06Config | |||
| 1.3.6.1.4.1.20044.115.9.1 | Nodepm600frs06CfgAccessCAisCsf | |||
| 1.3.6.1.4.1.20044.115.9.1.1 | Tablepm600frs06CfgClientcaiscsfTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.115.9.1.1.1 | Rowpm600frs06CfgClientcaiscsfEntry | not-accessible | current | Row definition for the accessCAisCsf table |
| 1.3.6.1.4.1.20044.115.9.1.1.1.1 | Columnpm600frs06CfgClientcaiscsfIndex | read-only | current | Index definition for the clientcaiscsf table |
| 1.3.6.1.4.1.20044.115.9.1.1.1.3 | Columnpm600frs06CfgReservePortn | read-write | current | CAIS mode on Client Port :This register enables/disables port laser shutdown on CAIS insertion condition |
| 1.3.6.1.4.1.20044.115.9.2 | Nodepm600frs06CfgStartup | |||
| 1.3.6.1.4.1.20044.115.9.2.1 | Tablepm600frs06CfgClientStartupTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.115.9.2.1.1 | Rowpm600frs06CfgClientStartupEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.115.9.2.1.1.1 | Columnpm600frs06CfgClientStartupIndex | read-only | current | Index definition for the clientStartup table |
| 1.3.6.1.4.1.20044.115.9.2.1.1.3 | Columnpm600frs06CfgSystConfPortPortn | read-write | current | Default Settings on Client Port :This register configures the default initialisation settings on the port. |
| 1.3.6.1.4.1.20044.115.9.2.1.1.4 | Columnpm600frs06CfgNetConfPortPortn | read-write | current | Default Settings on Client Port :This register configures the default initialisation settings on the port. |
| 1.3.6.1.4.1.20044.115.9.2.1.1.14 | Columnpm600frs06CfgOptionsPortPortn | read-write | current | Default Options on Client Port :This register configures the default options on the port. |
| 1.3.6.1.4.1.20044.115.9.2.2 | Tablepm600frs06CfgLineStartupTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.115.9.2.2.1 | Rowpm600frs06CfgLineStartupEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.115.9.2.2.1.1 | Columnpm600frs06CfgLineStartupIndex | read-only | current | Index definition for the lineStartup table |
| 1.3.6.1.4.1.20044.115.9.2.2.1.3 | Columnpm600frs06CfgSystConfLinePortn | read-write | current | Default Settings on Line :This register configures the default initialisation settings on Line |
| 1.3.6.1.4.1.20044.115.9.2.2.1.14 | Columnpm600frs06CfgOptionsLinePortn | read-write | current | Default Options on Line :This register configures the default options on the line |
| 1.3.6.1.4.1.20044.115.9.2.3 | Tablepm600frs06CfgXfpTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.115.9.2.3.1 | Rowpm600frs06CfgXfpEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.115.9.2.3.1.1 | Columnpm600frs06CfgXfpIndex | read-only | current | Index definition for the xfp table |
| 1.3.6.1.4.1.20044.115.9.2.3.1.3 | Columnpm600frs06CfgSystConfMsaLinePortn | read-write | current | Default settings on TRX :This register configures the default initialisation settings on TRX |
| 1.3.6.1.4.1.20044.115.9.2.3.1.6 | Columnpm600frs06CfgLineInputPowerHighAlarmPortn | read-write | current | Default settings on alarm threshold :This register configures the default initialisation settings on a threshold |
| 1.3.6.1.4.1.20044.115.9.2.3.1.7 | Columnpm600frs06CfgLineInputPowerHighWarningPortn | read-write | current | Default settings on warning threshold :This register configures the default initialisation settings on a threshold |
| 1.3.6.1.4.1.20044.115.9.2.3.1.8 | Columnpm600frs06CfgLineInputPowerLowWarningPortn | read-write | current | Default settings on warning threshold :This register configures the default initialisation settings on a threshold |
| 1.3.6.1.4.1.20044.115.9.2.3.1.9 | Columnpm600frs06CfgLineInputPowerLowAlarmPortn | read-write | current | Default settings on alarm threshold :This register configures the default initialisation settings on a threshold |
| 1.3.6.1.4.1.20044.115.9.2.3.1.10 | Columnpm600frs06CfgLineOutputPowerHighAlarmPortn | read-write | current | Default settings on alarm threshold :This register configures the default initialisation settings on a threshold |
| 1.3.6.1.4.1.20044.115.9.2.3.1.11 | Columnpm600frs06CfgLineOutputPowerHighWarningPortn | read-write | current | Default settings on warning threshold :This register configures the default initialisation settings on a threshold |
| 1.3.6.1.4.1.20044.115.9.2.3.1.12 | Columnpm600frs06CfgLineOutputPowerLowWarningPortn | read-write | current | Default settings on warning threshold :This register configures the default initialisation settings on a threshold |
| 1.3.6.1.4.1.20044.115.9.2.3.1.13 | Columnpm600frs06CfgLineOutputPowerLowAlarmPortn | read-write | current | Default settings on alarm threshold :This register configures the default initialisation settings on a threshold |
| 1.3.6.1.4.1.20044.115.9.2.3.1.14 | Columnpm600frs06CfgLineLossOfSignalPortn | read-write | current | Default settings on Los threshold :This register configures the default initialisation settings on a threshold |
| 1.3.6.1.4.1.20044.115.9.3 | Nodepm600frs06CfgLabels | |||
| 1.3.6.1.4.1.20044.115.9.3.1 | Tablepm600frs06CfgLabelclientTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.115.9.3.1.1 | Rowpm600frs06CfgLabelclientEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.115.9.3.1.1.1 | Columnpm600frs06CfgLabelclientIndex | read-only | current | Index definition for the labelclient table |
| 1.3.6.1.4.1.20044.115.9.3.1.1.3 | Columnpm600frs06CfgLabelclientPortn | read-write | current | Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. |
| 1.3.6.1.4.1.20044.115.9.3.2 | Tablepm600frs06CfgLabellineTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.115.9.3.2.1 | Rowpm600frs06CfgLabellineEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.115.9.3.2.1.1 | Columnpm600frs06CfgLabellineIndex | read-only | current | Index definition for the labelline table |
| 1.3.6.1.4.1.20044.115.9.3.2.1.3 | Columnpm600frs06CfgLabellinePortn | read-write | current | Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. |
| 1.3.6.1.4.1.20044.115.9.4 | Nodepm600frs06CfgStartuptlh | |||
| 1.3.6.1.4.1.20044.115.9.4.1 | Tablepm600frs06CfgOtxtlhTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.115.9.4.1.1 | Rowpm600frs06CfgOtxtlhEntry | not-accessible | current | Row definition for the startuptlh table |
| 1.3.6.1.4.1.20044.115.9.4.1.1.1 | Columnpm600frs06CfgOtxtlhIndex | read-only | current | Index definition for the otxtlh table |
| 1.3.6.1.4.1.20044.115.9.4.1.1.6 | Columnpm600frs06CfgLinePwrLaserPortn | read-write | current | Defaut Line output Power :This register configures the start-up output power of the Line tranceiver (Unit = dBm) |
| 1.3.6.1.4.1.20044.115.9.4.1.1.7 | Columnpm600frs06CfgLineFCurrentPortn | read-write | current | Default Line transceiver Rx Channel :This register configures the start-up laser channel of the Line Rx transceiver |
| 1.3.6.1.4.1.20044.115.9.4.1.1.8 | Columnpm600frs06CfgLineGridCurrentPortn | read-write | current | Default Line transceiver Grid :This register configures the start-up laser grid of the Line transceiver |
| 1.3.6.1.4.1.20044.115.9.4.1.1.9 | Columnpm600frs06CfgFPortn | read-write | current | Default Line TRX lowest Freq :This register configures the start-up lowest frequency of the Line transceiver |
| 1.3.6.1.4.1.20044.115.9.4.1.1.10 | Columnpm600frs06CfgTxLineFCurrentPortn | read-write | current | Default Line transceiver Tx Channel :This register configures the start-up laser channel of the Line Tx transceiver |
| 1.3.6.1.4.1.20044.115.9.4.1.1.11 | Columnpm600frs06CfgLineSpectralBandwidthPortn | read-only | current | Default Line Spectral Bandwidth :This OID displays the line signal spectral bandwidth (Ghz) |
| 1.3.6.1.4.1.20044.115.9.5 | Nodepm600frs06CfgOther | |||
| 1.3.6.1.4.1.20044.115.9.5.1 | Nodepm600frs06tablemoduleOther | |||
| 1.3.6.1.4.1.20044.115.9.5.1.2 | Scalarpm600frs06CfgclientMode | read-write | current | Default settings on Module :This register selects the configuration mode of the module |
| 1.3.6.1.4.1.20044.115.9.5.1.5 | Scalarpm600frs06CfgmoduleMode | read-write | current | Default settings on Module :This register selects the configuration mode of the module <Event> ObjectClearHistoPerf |
| 1.3.6.1.4.1.20044.115.9.6 | Nodepm600frs06CfgStartuptablefive | |||
| 1.3.6.1.4.1.20044.115.9.6.1 | Tablepm600frs06CfgOtxtlhcapabilitiesTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.115.9.6.1.1 | Rowpm600frs06CfgOtxtlhcapabilitiesEntry | not-accessible | current | Row definition for the startuptablefive table |
| 1.3.6.1.4.1.20044.115.9.6.1.1.1 | Columnpm600frs06CfgOtxtlhcapabilitiesIndex | read-only | current | Index definition for the otxtlhcapabilities table |
| 1.3.6.1.4.1.20044.115.9.6.1.1.3 | Columnpm600frs06CfgComponentTypePortn | read-only | current | Component parameters :This OID defines the component parameters |
| 1.3.6.1.4.1.20044.115.9.6.1.1.4 | Columnpm600frs06CfgMiscellaneousPortn | read-only | current | Miscellaneous default settings :This OID defines the miscellaneous parameters |
| 1.3.6.1.4.1.20044.115.9.6.1.1.5 | Columnpm600frs06CfgFirstChannelPortn | read-only | current | Number of the first channel of the component :This OID defines the first channel number of the PM |
| 1.3.6.1.4.1.20044.115.9.6.1.1.6 | Columnpm600frs06CfgLastChannelPortn | read-only | current | Number of the last channel of the component :This OID defines the last channel number of the PM |
| 1.3.6.1.4.1.20044.115.9.6.1.1.7 | Columnpm600frs06CfgGridPortn | read-only | current | Grid value of the component :This OID defines the grid of the PM |
| 1.3.6.1.4.1.20044.115.9.257 | Scalarpm600frs06CfgWriteConfiguration | read-write | current | Write configuration to module:This OID writes the complete configuration to the module |
| 1.3.6.1.4.1.20044.115.10 | Nodepm600frs06traps | |||
| 1.3.6.1.4.1.20044.115.10.2 | Scalarpm600frs06trapPortNumber | read-only | current | Last port which generates a trap |
| 1.3.6.1.4.1.20044.115.10.3 | Scalarpm600frs06trapLineNumber | read-only | current | Last Line which generates a trap |
| 1.3.6.1.4.1.20044.115.10.4 | Scalarpm600frs06trapBoardNumber | read-only | current | Last module which generates a trap |
| 1.3.6.1.4.1.20044.115.10.30 | Notificationpm600frs06LineTrapNotUrgentGoesOn | current | Not urgent Line default is activated | |
| 1.3.6.1.4.1.20044.115.10.31 | Notificationpm600frs06LineTrapNotUrgentGoesOff | current | Not urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.115.10.32 | Notificationpm600frs06LineTrapUrgentGoesOn | current | Urgent Line default is activated | |
| 1.3.6.1.4.1.20044.115.10.33 | Notificationpm600frs06LineTrapUrgentGoesOff | current | Urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.115.10.34 | Notificationpm600frs06LineTrapCritGoesOn | current | Critical Line default is activated | |
| 1.3.6.1.4.1.20044.115.10.35 | Notificationpm600frs06LineTrapCritGoesOff | current | Critical Line default disappeared | |
| 1.3.6.1.4.1.20044.115.10.40 | Notificationpm600frs06ClientTrapNotUrgentGoesOn | current | Not urgent client default is activated | |
| 1.3.6.1.4.1.20044.115.10.41 | Notificationpm600frs06ClientTrapNotUrgentGoesOff | current | Not urgent client default disappeared | |
| 1.3.6.1.4.1.20044.115.10.42 | Notificationpm600frs06ClientTrapUrgentGoesOn | current | Urgent client default is activated | |
| 1.3.6.1.4.1.20044.115.10.43 | Notificationpm600frs06ClientTrapUrgentGoesOff | current | Urgent client default disappeared | |
| 1.3.6.1.4.1.20044.115.10.44 | Notificationpm600frs06ClientTrapCritGoesOn | current | Critical client default is activated | |
| 1.3.6.1.4.1.20044.115.10.45 | Notificationpm600frs06ClientTrapCritGoesOff | current | Critical client default disappeared | |
| 1.3.6.1.4.1.20044.115.10.50 | Notificationpm600frs06PowerTrapUrgentGoesOn | current | Urgent power supply default is activated | |
| 1.3.6.1.4.1.20044.115.10.51 | Notificationpm600frs06PowerTrapUrgentGoesOff | current | Urgent power supply default disappeared | |
| 1.3.6.1.4.1.20044.115.11 | Nodepm600frs06Monitoring | |||
| 1.3.6.1.4.1.20044.115.11.1 | Nodepm600frs06MonOther | |||
| 1.3.6.1.4.1.20044.115.11.1.3 | Nodepm600frs06MonRmon | |||
| 1.3.6.1.4.1.20044.115.11.2 | Nodepm600frs06MonClient | |||
| 1.3.6.1.4.1.20044.115.11.2.4 | Nodepm600frs06MonClientRmonCounter | |||
| 1.3.6.1.4.1.20044.115.11.2.4.16 | Tablepm600frs06MonupRmonBytesCounterClientInputTable | not-accessible | current | List of pm600frs06MonupRmonBytesCounterClientInput Article |
| 1.3.6.1.4.1.20044.115.11.2.4.16.1 | Rowpm600frs06MonupRmonBytesCounterClientInputEntry | not-accessible | current | Row definition for the pm600frs06MonupRmonBytesCounterClientInput table |
| 1.3.6.1.4.1.20044.115.11.2.4.16.1.1 | Columnpm600frs06MonupRmonBytesCounterClientInputIndex | read-only | current | Index definition for the pm600frs06MonupRmonBytesCounterClientInput table |
| 1.3.6.1.4.1.20044.115.11.2.4.16.1.2 | Columnpm600frs06MonupRmonBytesCounterClientInputValuePortn | read-only | current | Client Input Bytes :This counter is increased each time a data byte is received on the client port <Help> This counter gives the number of bytes received on th… |
| 1.3.6.1.4.1.20044.115.11.2.4.16.1.3 | Columnpm600frs06MonupRmonBytesCounterClientInputErrorPortn | read-only | current | Bytes Counter Error :This OID when set indicates the Bytes counter value is invalid on client port |
| 1.3.6.1.4.1.20044.115.11.2.4.16.1.4 | Columnpm600frs06MonupRmonBytesCounterClientInputOverloadPortn | read-only | current | Bytes Counter Overload :This OID when set indicates a Bytes counter overload on client port |
| 1.3.6.1.4.1.20044.115.11.2.4.48 | Tablepm600frs06MonupRmonCrcErrorsCounterClientInputTable | not-accessible | current | List of pm600frs06MonupRmonCrcErrorsCounterClientInput Article |
| 1.3.6.1.4.1.20044.115.11.2.4.48.1 | Rowpm600frs06MonupRmonCrcErrorsCounterClientInputEntry | not-accessible | current | Row definition for the pm600frs06MonupRmonCrcErrorsCounterClientInput table |
| 1.3.6.1.4.1.20044.115.11.2.4.48.1.1 | Columnpm600frs06MonupRmonCrcErrorsCounterClientInputIndex | read-only | current | Index definition for the pm600frs06MonupRmonCrcErrorsCounterClientInput table |
| 1.3.6.1.4.1.20044.115.11.2.4.48.1.2 | Columnpm600frs06MonupRmonCrcErrorsCounterClientInputValuePortn | read-only | current | Client Input CRC Errors :This counter is increased each time a CRC error is detected on the client port<Help> This counter gives the number of CRC Errors recei… |
| 1.3.6.1.4.1.20044.115.11.2.4.48.1.3 | Columnpm600frs06MonupRmonCrcErrorsCounterClientInputErrorPortn | read-only | current | CRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on client port |
| 1.3.6.1.4.1.20044.115.11.2.4.48.1.4 | Columnpm600frs06MonupRmonCrcErrorsCounterClientInputOverloadPortn | read-only | current | CRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on client port |
| 1.3.6.1.4.1.20044.115.11.2.4.80 | Tablepm600frs06MonupRmonPacketsCounterClientInputTable | not-accessible | current | List of pm600frs06MonupRmonPacketsCounterClientInput Article |
| 1.3.6.1.4.1.20044.115.11.2.4.80.1 | Rowpm600frs06MonupRmonPacketsCounterClientInputEntry | not-accessible | current | Row definition for the pm600frs06MonupRmonPacketsCounterClientInput table |
| 1.3.6.1.4.1.20044.115.11.2.4.80.1.1 | Columnpm600frs06MonupRmonPacketsCounterClientInputIndex | read-only | current | Index definition for the pm600frs06MonupRmonPacketsCounterClientInput table |
| 1.3.6.1.4.1.20044.115.11.2.4.80.1.2 | Columnpm600frs06MonupRmonPacketsCounterClientInputValuePortn | read-only | current | Client Input Packets :This counter is increased each time a packet is received on the client port <Help> This counter gives the number of packets received on t… |
| 1.3.6.1.4.1.20044.115.11.2.4.80.1.3 | Columnpm600frs06MonupRmonPacketsCounterClientInputErrorPortn | read-only | current | Packets Counter Error :This OID when set indicates the Packets counter value is invalid on client port |
| 1.3.6.1.4.1.20044.115.11.2.4.80.1.4 | Columnpm600frs06MonupRmonPacketsCounterClientInputOverloadPortn | read-only | current | Packets Counter Overload :This OID when set indicates a Packets counter overload on client port |
| 1.3.6.1.4.1.20044.115.11.2.4.112 | Tablepm600frs06MonupRmonBroadcastCounterClientInputTable | not-accessible | current | List of pm600frs06MonupRmonBroadcastCounterClientInput Article |
| 1.3.6.1.4.1.20044.115.11.2.4.112.1 | Rowpm600frs06MonupRmonBroadcastCounterClientInputEntry | not-accessible | current | Row definition for the pm600frs06MonupRmonBroadcastCounterClientInput table |
| 1.3.6.1.4.1.20044.115.11.2.4.112.1.1 | Columnpm600frs06MonupRmonBroadcastCounterClientInputIndex | read-only | current | Index definition for the pm600frs06MonupRmonBroadcastCounterClientInput table |
| 1.3.6.1.4.1.20044.115.11.2.4.112.1.2 | Columnpm600frs06MonupRmonBroadcastCounterClientInputValuePortn | read-only | current | Client Input Broadcast Packets :This counter is increased each time a broadcast packet is received on the client port <Help> This counter gives the number of B… |
| 1.3.6.1.4.1.20044.115.11.2.4.112.1.3 | Columnpm600frs06MonupRmonBroadcastCounterClientInputErrorPortn | read-only | current | Broadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.115.11.2.4.112.1.4 | Columnpm600frs06MonupRmonBroadcastCounterClientInputOverloadPortn | read-only | current | Broadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port |
| 1.3.6.1.4.1.20044.115.11.2.4.144 | Tablepm600frs06MonupRmonMulticastCounterClientInputTable | not-accessible | current | List of pm600frs06MonupRmonMulticastCounterClientInput Article |
| 1.3.6.1.4.1.20044.115.11.2.4.144.1 | Rowpm600frs06MonupRmonMulticastCounterClientInputEntry | not-accessible | current | Row definition for the pm600frs06MonupRmonMulticastCounterClientInput table |
| 1.3.6.1.4.1.20044.115.11.2.4.144.1.1 | Columnpm600frs06MonupRmonMulticastCounterClientInputIndex | read-only | current | Index definition for the pm600frs06MonupRmonMulticastCounterClientInput table |
| 1.3.6.1.4.1.20044.115.11.2.4.144.1.2 | Columnpm600frs06MonupRmonMulticastCounterClientInputValuePortn | read-only | current | Client Input Multicast Packets :This counter is increased each time a Multicast packet is received on the client port <Help> This counter gives the number of M… |
| 1.3.6.1.4.1.20044.115.11.2.4.144.1.3 | Columnpm600frs06MonupRmonMulticastCounterClientInputErrorPortn | read-only | current | Multicast Counter Error :This OID when set indicates the Multicast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.115.11.2.4.144.1.4 | Columnpm600frs06MonupRmonMulticastCounterClientInputOverloadPortn | read-only | current | Multicast Counter Overload :This OID when set indicates a Multicast counter overload on client port |
| 1.3.6.1.4.1.20044.115.11.2.4.176 | Tablepm600frs06MonupRmonPauseFrameCounterClientInputTable | not-accessible | current | List of pm600frs06MonupRmonPauseFrameCounterClientInput Article |
| 1.3.6.1.4.1.20044.115.11.2.4.176.1 | Rowpm600frs06MonupRmonPauseFrameCounterClientInputEntry | not-accessible | current | Row definition for the pm600frs06MonupRmonPauseFrameCounterClientInput table |
| 1.3.6.1.4.1.20044.115.11.2.4.176.1.1 | Columnpm600frs06MonupRmonPauseFrameCounterClientInputIndex | read-only | current | Index definition for the pm600frs06MonupRmonPauseFrameCounterClientInput table |
| 1.3.6.1.4.1.20044.115.11.2.4.176.1.2 | Columnpm600frs06MonupRmonPauseFrameCounterClientInputValuePortn | read-only | current | Client Input Pause Frames :This counter is increased each time a Pause frame is received on the client port <Help> This counter gives the number of Pause frame… |
| 1.3.6.1.4.1.20044.115.11.2.4.176.1.3 | Columnpm600frs06MonupRmonPauseFrameCounterClientInputErrorPortn | read-only | current | Pause Counter Error :This OID when set indicates the Pause counter value is invalid on client port |
| 1.3.6.1.4.1.20044.115.11.2.4.176.1.4 | Columnpm600frs06MonupRmonPauseFrameCounterClientInputOverloadPortn | read-only | current | Pause Counter Overload :This OID when set indicates a Pause counter overload on client port |
| 1.3.6.1.4.1.20044.115.11.2.4.304 | Tablepm600frs06MonupRmonUnicastCounterClientInputTable | not-accessible | current | List of pm600frs06MonupRmonUnicastCounterClientInput Article |
| 1.3.6.1.4.1.20044.115.11.2.4.304.1 | Rowpm600frs06MonupRmonUnicastCounterClientInputEntry | not-accessible | current | Row definition for the pm600frs06MonupRmonUnicastCounterClientInput table |
| 1.3.6.1.4.1.20044.115.11.2.4.304.1.1 | Columnpm600frs06MonupRmonUnicastCounterClientInputIndex | read-only | current | Index definition for the pm600frs06MonupRmonUnicastCounterClientInput table |
| 1.3.6.1.4.1.20044.115.11.2.4.304.1.2 | Columnpm600frs06MonupRmonUnicastCounterClientInputValuePortn | read-only | current | Client Input Unicast Packets :This counter is increased each time a Unicast packet is received on the client port <Help> This counter gives the number of Unica… |
| 1.3.6.1.4.1.20044.115.11.2.4.304.1.3 | Columnpm600frs06MonupRmonUnicastCounterClientInputErrorPortn | read-only | current | Unicast Counter Error :This OID when set indicates the Unicast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.115.11.2.4.304.1.4 | Columnpm600frs06MonupRmonUnicastCounterClientInputOverloadPortn | read-only | current | Unicast Counter Overload :This OID when set indicates a Unicast counter overload on client port |
| 1.3.6.1.4.1.20044.115.11.2.4.336 | Tablepm600frs06MonupRmonNonunicastCounterClientInputTable | not-accessible | current | List of pm600frs06MonupRmonNonunicastCounterClientInput Article |
| 1.3.6.1.4.1.20044.115.11.2.4.336.1 | Rowpm600frs06MonupRmonNonunicastCounterClientInputEntry | not-accessible | current | Row definition for the pm600frs06MonupRmonNonunicastCounterClientInput table |
| 1.3.6.1.4.1.20044.115.11.2.4.336.1.1 | Columnpm600frs06MonupRmonNonunicastCounterClientInputIndex | read-only | current | Index definition for the pm600frs06MonupRmonNonunicastCounterClientInput table |
| 1.3.6.1.4.1.20044.115.11.2.4.336.1.2 | Columnpm600frs06MonupRmonNonunicastCounterClientInputValuePortn | read-only | current | Client Input Non Unicast Packets :This counter is increased each time a Non-Unicast packet is received on the client port <Help> This counter gives the number … |
| 1.3.6.1.4.1.20044.115.11.2.4.336.1.3 | Columnpm600frs06MonupRmonNonunicastCounterClientInputErrorPortn | read-only | current | Non Unicast Counter Error :This OID when set indicates the Non-Unicast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.115.11.2.4.336.1.4 | Columnpm600frs06MonupRmonNonunicastCounterClientInputOverloadPortn | read-only | current | Non Unicast Counter Overload :This OID when set indicates a Non-Unicast counter overload on client port |
| 1.3.6.1.4.1.20044.115.11.2.4.400 | Tablepm600frs06MondownRmonBytesCounterClientOutputTable | not-accessible | current | List of pm600frs06MondownRmonBytesCounterClientOutput Article |
| 1.3.6.1.4.1.20044.115.11.2.4.400.1 | Rowpm600frs06MondownRmonBytesCounterClientOutputEntry | not-accessible | current | Row definition for the pm600frs06MondownRmonBytesCounterClientOutput table |
| 1.3.6.1.4.1.20044.115.11.2.4.400.1.1 | Columnpm600frs06MondownRmonBytesCounterClientOutputIndex | read-only | current | Index definition for the pm600frs06MondownRmonBytesCounterClientOutput table |
| 1.3.6.1.4.1.20044.115.11.2.4.400.1.2 | Columnpm600frs06MondownRmonBytesCounterClientOutputValuePortn | read-only | current | Client Output Bytes :This counter is increased each time a data byte is transmitted on the client port <Help> This counter gives the number of bytes transmitte… |
| 1.3.6.1.4.1.20044.115.11.2.4.400.1.3 | Columnpm600frs06MondownRmonBytesCounterClientOutputErrorPortn | read-only | current | Bytes Counter Error :This OID when set indicates the Bytes counter value is invalid on client port |
| 1.3.6.1.4.1.20044.115.11.2.4.400.1.4 | Columnpm600frs06MondownRmonBytesCounterClientOutputOverloadPortn | read-only | current | Bytes Counter Overload :This OID when set indicates a Bytes counter overload on client port |
| 1.3.6.1.4.1.20044.115.11.2.4.432 | Tablepm600frs06MondownRmonCrcErrorsCounterClientOutputTable | not-accessible | current | List of pm600frs06MondownRmonCrcErrorsCounterClientOutput Article |
| 1.3.6.1.4.1.20044.115.11.2.4.432.1 | Rowpm600frs06MondownRmonCrcErrorsCounterClientOutputEntry | not-accessible | current | Row definition for the pm600frs06MondownRmonCrcErrorsCounterClientOutput table |
| 1.3.6.1.4.1.20044.115.11.2.4.432.1.1 | Columnpm600frs06MondownRmonCrcErrorsCounterClientOutputIndex | read-only | current | Index definition for the pm600frs06MondownRmonCrcErrorsCounterClientOutput table |
| 1.3.6.1.4.1.20044.115.11.2.4.432.1.2 | Columnpm600frs06MondownRmonCrcErrorsCounterClientOutputValuePortn | read-only | current | Client Output CRC Errors :This counter is increased each time a CRC error is detected on the transmit client port <Help> This counter gives the number of CRC E… |
| 1.3.6.1.4.1.20044.115.11.2.4.432.1.3 | Columnpm600frs06MondownRmonCrcErrorsCounterClientOutputErrorPortn | read-only | current | CRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on client port |
| 1.3.6.1.4.1.20044.115.11.2.4.432.1.4 | Columnpm600frs06MondownRmonCrcErrorsCounterClientOutputOverloadPortn | read-only | current | CRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on client port |
| 1.3.6.1.4.1.20044.115.11.2.4.464 | Tablepm600frs06MondownRmonPacketsCounterClientOutputTable | not-accessible | current | List of pm600frs06MondownRmonPacketsCounterClientOutput Article |
| 1.3.6.1.4.1.20044.115.11.2.4.464.1 | Rowpm600frs06MondownRmonPacketsCounterClientOutputEntry | not-accessible | current | Row definition for the pm600frs06MondownRmonPacketsCounterClientOutput table |
| 1.3.6.1.4.1.20044.115.11.2.4.464.1.1 | Columnpm600frs06MondownRmonPacketsCounterClientOutputIndex | read-only | current | Index definition for the pm600frs06MondownRmonPacketsCounterClientOutput table |
| 1.3.6.1.4.1.20044.115.11.2.4.464.1.2 | Columnpm600frs06MondownRmonPacketsCounterClientOutputValuePortn | read-only | current | Client Output Packets :This counter is increased each time a packet is transmitted on the client port <Help> This counter gives the number of packets transmitt… |
| 1.3.6.1.4.1.20044.115.11.2.4.464.1.3 | Columnpm600frs06MondownRmonPacketsCounterClientOutputErrorPortn | read-only | current | Packets Counter Error :This OID when set indicates the Packets counter value is invalid on client port |
| 1.3.6.1.4.1.20044.115.11.2.4.464.1.4 | Columnpm600frs06MondownRmonPacketsCounterClientOutputOverloadPortn | read-only | current | Packets Counter Overload :This OID when set indicates a Packets counter overload on client port |
| 1.3.6.1.4.1.20044.115.11.2.4.496 | Tablepm600frs06MondownRmonBroadcastCounterClientOutputTable | not-accessible | current | List of pm600frs06MondownRmonBroadcastCounterClientOutput Article |
| 1.3.6.1.4.1.20044.115.11.2.4.496.1 | Rowpm600frs06MondownRmonBroadcastCounterClientOutputEntry | not-accessible | current | Row definition for the pm600frs06MondownRmonBroadcastCounterClientOutput table |
| 1.3.6.1.4.1.20044.115.11.2.4.496.1.1 | Columnpm600frs06MondownRmonBroadcastCounterClientOutputIndex | read-only | current | Index definition for the pm600frs06MondownRmonBroadcastCounterClientOutput table |
| 1.3.6.1.4.1.20044.115.11.2.4.496.1.2 | Columnpm600frs06MondownRmonBroadcastCounterClientOutputValuePortn | read-only | current | Client Output Broadcast Packets :This counter is increased each time a broadcast packet is transmitted on the client port <Help> This counter gives the number … |
| 1.3.6.1.4.1.20044.115.11.2.4.496.1.3 | Columnpm600frs06MondownRmonBroadcastCounterClientOutputErrorPortn | read-only | current | Broadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.115.11.2.4.496.1.4 | Columnpm600frs06MondownRmonBroadcastCounterClientOutputOverloadPortn | read-only | current | Broadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port |
| 1.3.6.1.4.1.20044.115.11.2.4.528 | Tablepm600frs06MondownRmonMulticastCounterClientOutputTable | not-accessible | current | List of pm600frs06MondownRmonMulticastCounterClientOutput Article |
| 1.3.6.1.4.1.20044.115.11.2.4.528.1 | Rowpm600frs06MondownRmonMulticastCounterClientOutputEntry | not-accessible | current | Row definition for the pm600frs06MondownRmonMulticastCounterClientOutput table |
| 1.3.6.1.4.1.20044.115.11.2.4.528.1.1 | Columnpm600frs06MondownRmonMulticastCounterClientOutputIndex | read-only | current | Index definition for the pm600frs06MondownRmonMulticastCounterClientOutput table |
| 1.3.6.1.4.1.20044.115.11.2.4.528.1.2 | Columnpm600frs06MondownRmonMulticastCounterClientOutputValuePortn | read-only | current | Client Output Multicast Packets :This counter is increased each time a Multicast packet is transmitted on the client port <Help> This counter gives the number … |
| 1.3.6.1.4.1.20044.115.11.2.4.528.1.3 | Columnpm600frs06MondownRmonMulticastCounterClientOutputErrorPortn | read-only | current | Multicast Counter Error :This OID when set indicates the Multicast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.115.11.2.4.528.1.4 | Columnpm600frs06MondownRmonMulticastCounterClientOutputOverloadPortn | read-only | current | Multicast Counter Overload :This OID when set indicates a Multicast counter overload on client port |
| 1.3.6.1.4.1.20044.115.11.2.4.560 | Tablepm600frs06MondownRmonPauseFrameCounterClientOutputTable | not-accessible | current | List of pm600frs06MondownRmonPauseFrameCounterClientOutput Article |
| 1.3.6.1.4.1.20044.115.11.2.4.560.1 | Rowpm600frs06MondownRmonPauseFrameCounterClientOutputEntry | not-accessible | current | Row definition for the pm600frs06MondownRmonPauseFrameCounterClientOutput table |
| 1.3.6.1.4.1.20044.115.11.2.4.560.1.1 | Columnpm600frs06MondownRmonPauseFrameCounterClientOutputIndex | read-only | current | Index definition for the pm600frs06MondownRmonPauseFrameCounterClientOutput table |
| 1.3.6.1.4.1.20044.115.11.2.4.560.1.2 | Columnpm600frs06MondownRmonPauseFrameCounterClientOutputValuePortn | read-only | current | Client Output Pause Frames :This counter is increased each time a Pause frame is transmitted on the client port <Help> This counter gives the number of Pause f… |
| 1.3.6.1.4.1.20044.115.11.2.4.560.1.3 | Columnpm600frs06MondownRmonPauseFrameCounterClientOutputErrorPortn | read-only | current | Pause Counter Error :This OID when set indicates the Pause counter value is invalid on client port |
| 1.3.6.1.4.1.20044.115.11.2.4.560.1.4 | Columnpm600frs06MondownRmonPauseFrameCounterClientOutputOverloadPortn | read-only | current | Pause Counter Overload :This OID when set indicates a Pause counter overload on client port |
| 1.3.6.1.4.1.20044.115.11.2.4.688 | Tablepm600frs06MondownRmonUnicastCounterClientOutputTable | not-accessible | current | List of pm600frs06MondownRmonUnicastCounterClientOutput Article |
| 1.3.6.1.4.1.20044.115.11.2.4.688.1 | Rowpm600frs06MondownRmonUnicastCounterClientOutputEntry | not-accessible | current | Row definition for the pm600frs06MondownRmonUnicastCounterClientOutput table |
| 1.3.6.1.4.1.20044.115.11.2.4.688.1.1 | Columnpm600frs06MondownRmonUnicastCounterClientOutputIndex | read-only | current | Index definition for the pm600frs06MondownRmonUnicastCounterClientOutput table |
| 1.3.6.1.4.1.20044.115.11.2.4.688.1.2 | Columnpm600frs06MondownRmonUnicastCounterClientOutputValuePortn | read-only | current | Client Output Unicast Packets :This counter is increased each time a Unicast packet is transmitted on the client port <Help> This counter gives the number of U… |
| 1.3.6.1.4.1.20044.115.11.2.4.688.1.3 | Columnpm600frs06MondownRmonUnicastCounterClientOutputErrorPortn | read-only | current | Unicast Counter Error :This OID when set indicates the Unicast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.115.11.2.4.688.1.4 | Columnpm600frs06MondownRmonUnicastCounterClientOutputOverloadPortn | read-only | current | Unicast Counter Overload :This OID when set indicates a Unicast counter overload on client port |
| 1.3.6.1.4.1.20044.115.11.2.4.720 | Tablepm600frs06MondownRmonNonunicastCounterClientOutputTable | not-accessible | current | List of pm600frs06MondownRmonNonunicastCounterClientOutput Article |
| 1.3.6.1.4.1.20044.115.11.2.4.720.1 | Rowpm600frs06MondownRmonNonunicastCounterClientOutputEntry | not-accessible | current | Row definition for the pm600frs06MondownRmonNonunicastCounterClientOutput table |
| 1.3.6.1.4.1.20044.115.11.2.4.720.1.1 | Columnpm600frs06MondownRmonNonunicastCounterClientOutputIndex | read-only | current | Index definition for the pm600frs06MondownRmonNonunicastCounterClientOutput table |
| 1.3.6.1.4.1.20044.115.11.2.4.720.1.2 | Columnpm600frs06MondownRmonNonunicastCounterClientOutputValuePortn | read-only | current | Client Output Non Unicast Packets :This counter is increased each time a Non-Unicast packet is transmitted on the client port <Help> This counter gives the num… |
| 1.3.6.1.4.1.20044.115.11.2.4.720.1.3 | Columnpm600frs06MondownRmonNonunicastCounterClientOutputErrorPortn | read-only | current | Non Unicast Counter Error :This OID when set indicates the Non-Unicast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.115.11.2.4.720.1.4 | Columnpm600frs06MondownRmonNonunicastCounterClientOutputOverloadPortn | read-only | current | Non Unicast Counter Overload :This OID when set indicates a Non-Unicast counter overload on client port |
| 1.3.6.1.4.1.20044.115.11.5 | Nodepm600frs06MonPerfOther | |||
| 1.3.6.1.4.1.20044.115.11.5.1 | Nodepm600frs06MonPerfSync | |||
| 1.3.6.1.4.1.20044.115.11.5.1.257 | Scalarpm600frs06PerfEnable | read-write | current | Perf. Mon. Enable :This OID enables the Performance Monitoring application |
| 1.3.6.1.4.1.20044.115.11.5.1.259 | Scalarpm600frs06Perf15minSync | read-write | current | Perf. Mon. 15-min sync. :This OID must be used in external synchronisation mode only to send a 15-min synchronisation command |
| 1.3.6.1.4.1.20044.115.11.5.1.260 | Scalarpm600frs06Perf24hSync | read-write | current | Perf. Mon. 24-hours sync. :This OID must be used in external synchronisation mode only to send a 24-hours synchronisation command |
| 1.3.6.1.4.1.20044.115.11.5.2 | Nodepm600frs06MonPerfTimeStamp | |||
| 1.3.6.1.4.1.20044.115.11.5.2.1 | Scalarpm600frs06Perf15MinShort | read-write | current | 15-min period is short :This OID indicates that the 15-min period lasts less than 890 seconds |
| 1.3.6.1.4.1.20044.115.11.5.2.2 | Scalarpm600frs06Perf15MinLong | read-write | current | 15-min period is long :This OID indicates that the 15-min period lasts more than 910 seconds |
| 1.3.6.1.4.1.20044.115.11.5.2.5 | Scalarpm600frs06Perf24HoursShort | read-write | current | 24-hours period is short :This OID indicates that 24-hours period lasts less than 86390 seconds |
| 1.3.6.1.4.1.20044.115.11.5.2.6 | Scalarpm600frs06Perf24HoursLong | read-write | current | 24-hours period is long :This OID indicates that 24-hours period lasts more than 86410 seconds |
| 1.3.6.1.4.1.20044.115.11.5.2.7 | Scalarpm600frs06PerfCurrent15MinElapsedTime | read-write | current | Current 15min period Elapsed Time :This OID gives the number of seconds elapsed in the current 15-minutes period |
| 1.3.6.1.4.1.20044.115.11.5.2.8 | Scalarpm600frs06PerfCurrent24HoursElapsedTime | read-write | current | Current 24hours period Elapsed Time :This OID gives the number of seconds elapsed in the current 24-hours period |
| 1.3.6.1.4.1.20044.115.11.6 | Nodepm600frs06MonPerfClient | |||
| 1.3.6.1.4.1.20044.115.11.6.16 | Tablepm600frs06PerfTelecomInputClientCurrent15StatTable | not-accessible | current | List of pm600frs06PerfTelecomInputClientCurrent15Stat Article |
| 1.3.6.1.4.1.20044.115.11.6.16.1 | Rowpm600frs06PerfTelecomInputClientCurrent15StatEntry | not-accessible | current | Row definition for the pm600frs06PerfTelecomInputClientCurrent15Stat table |
| 1.3.6.1.4.1.20044.115.11.6.16.1.1 | Columnpm600frs06PerfTelecomInputClientCurrent15StatIndex | read-only | current | Index definition for the pm600frs06PerfTelecomInputClientCurrent15Stat table |
| 1.3.6.1.4.1.20044.115.11.6.16.1.2 | Columnpm600frs06PerfTelecomInputClientCurrent15StatInvCvPortn | read-only | current | Current 15-min EBC counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.16.1.3 | Columnpm600frs06PerfTelecomInputClientCurrent15StatCvValuePortn | read-only | current | Current 15-min EBC counter :This OID gives the current 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.115.11.6.16.1.4 | Columnpm600frs06PerfTelecomInputClientCurrent15StatInvEsPortn | read-only | current | Current 15-min ES counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.16.1.5 | Columnpm600frs06PerfTelecomInputClientCurrent15StatEsValuePortn | read-only | current | Current 15-min ES counter :This OID gives the current 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.16.1.6 | Columnpm600frs06PerfTelecomInputClientCurrent15StatInvSesPortn | read-only | current | Current 15-min SES counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.16.1.7 | Columnpm600frs06PerfTelecomInputClientCurrent15StatSesValuePortn | read-only | current | Current 15-min SES counter :This OID gives the current 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.16.1.8 | Columnpm600frs06PerfTelecomInputClientCurrent15StatInvSefsPortn | read-only | current | Current 15-min SEFS counter inv. :This OID indicates that the current 15-min severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.16.1.9 | Columnpm600frs06PerfTelecomInputClientCurrent15StatSefsValuePortn | read-only | current | Current 15-min SEFS counter :This OID gives the current 15-min severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.16.1.10 | Columnpm600frs06PerfTelecomInputClientCurrent15StatInvUasPortn | read-only | current | Current 15-min UAS counter inv. :This OID indicates that the current 15-min UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.16.1.11 | Columnpm600frs06PerfTelecomInputClientCurrent15StatUasValuePortn | read-only | current | Current 15-min UAS counter :This OID gives the current 15-min UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.48 | Tablepm600frs06PerfTelecomInputClientPast15StatHistoryPort1Table | not-accessible | current | List of pm600frs06PerfTelecomInputClientPast15StatHistory Article |
| 1.3.6.1.4.1.20044.115.11.6.48.1 | Rowpm600frs06PerfTelecomInputClientPast15StatHistoryPort1Entry | not-accessible | current | Row definition for the pm600frs06PerfTelecomInputClientPast15StatHistory table |
| 1.3.6.1.4.1.20044.115.11.6.48.1.1 | Columnpm600frs06PerfTelecomInputClientPast15StatHistoryPort1Index | read-only | current | Index definition for the pm600frs06PerfTelecomInputClientPast15StatHistory table |
| 1.3.6.1.4.1.20044.115.11.6.48.1.2 | Columnpm600frs06PerfTelecomInputClientPast15StatHistoryInvCvPort1 | read-only | current | Previous 15-min EBC counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.48.1.3 | Columnpm600frs06PerfTelecomInputClientPast15StatHistoryCvValuePort1 | read-only | current | Previous 15-min EBC counter :This OID gives the previous 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.115.11.6.48.1.4 | Columnpm600frs06PerfTelecomInputClientPast15StatHistoryInvEsPort1 | read-only | current | Previous 15-min ES counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.48.1.5 | Columnpm600frs06PerfTelecomInputClientPast15StatHistoryEsValuePort1 | read-only | current | Previous 15-min ES counter :This OID gives the previous 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.48.1.6 | Columnpm600frs06PerfTelecomInputClientPast15StatHistoryInvSesPort1 | read-only | current | Previous 15-min SES counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.48.1.7 | Columnpm600frs06PerfTelecomInputClientPast15StatHistorySesValuePort1 | read-only | current | Previous 15-min SES counter :This OID gives the previous 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.48.1.8 | Columnpm600frs06PerfTelecomInputClientPast15StatHistoryInvSefsPort1 | read-only | current | Previous 15-min SEFS counter inv. :This OID indicates that the previous 15-min severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.48.1.9 | Columnpm600frs06PerfTelecomInputClientPast15StatHistorySefsValuePort1 | read-only | current | Previous 15-min SEFS counter :This OID gives the previous 15-min severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.48.1.10 | Columnpm600frs06PerfTelecomInputClientPast15StatHistoryInvUasPort1 | read-only | current | Previous 15-min UAS counter inv. :This OID indicates that the previous 15-min UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.48.1.11 | Columnpm600frs06PerfTelecomInputClientPast15StatHistoryUasValuePort1 | read-only | current | Previous 15-min UAS counter :This OID gives the previous 15-min UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.80 | Tablepm600frs06PerfTelecomInputClientCurrent24StatTable | not-accessible | current | List of pm600frs06PerfTelecomInputClientCurrent24Stat Article |
| 1.3.6.1.4.1.20044.115.11.6.80.1 | Rowpm600frs06PerfTelecomInputClientCurrent24StatEntry | not-accessible | current | Row definition for the pm600frs06PerfTelecomInputClientCurrent24Stat table |
| 1.3.6.1.4.1.20044.115.11.6.80.1.1 | Columnpm600frs06PerfTelecomInputClientCurrent24StatIndex | read-only | current | Index definition for the pm600frs06PerfTelecomInputClientCurrent24Stat table |
| 1.3.6.1.4.1.20044.115.11.6.80.1.2 | Columnpm600frs06PerfTelecomInputClientCurrent24StatInvCvPortn | read-only | current | Current 24-hours EBC counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.80.1.3 | Columnpm600frs06PerfTelecomInputClientCurrent24StatCvValuePortn | read-only | current | Current 24-hours EBC counter :This OID gives the current 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.115.11.6.80.1.4 | Columnpm600frs06PerfTelecomInputClientCurrent24StatInvEsPortn | read-only | current | Current 24-hours ES counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.80.1.5 | Columnpm600frs06PerfTelecomInputClientCurrent24StatEsValuePortn | read-only | current | Current 24-hours ES counter :This OID gives the current 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.80.1.6 | Columnpm600frs06PerfTelecomInputClientCurrent24StatInvSesPortn | read-only | current | Current 24-hours SES counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.80.1.7 | Columnpm600frs06PerfTelecomInputClientCurrent24StatSesValuePortn | read-only | current | Current 24-hours SES counter :This OID gives the current 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.80.1.8 | Columnpm600frs06PerfTelecomInputClientCurrent24StatInvSefsPortn | read-only | current | Current 24-hours SEFS counter inv. :This OID indicates that the current 24-hours severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.80.1.9 | Columnpm600frs06PerfTelecomInputClientCurrent24StatSefsValuePortn | read-only | current | Current 24-hours SEFS counter :This OID gives the current 24-hours severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.80.1.10 | Columnpm600frs06PerfTelecomInputClientCurrent24StatInvUasPortn | read-only | current | Current 24-hours UAS counter inv. :This OID indicates that the current 24-hours UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.80.1.11 | Columnpm600frs06PerfTelecomInputClientCurrent24StatUasValuePortn | read-only | current | Current 24-hours UAS counter :This OID gives the current 24-hours UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.112 | Tablepm600frs06PerfTelecomInputClientPast24StatHistoryPort1Table | not-accessible | current | List of pm600frs06PerfTelecomInputClientPast24StatHistory Article |
| 1.3.6.1.4.1.20044.115.11.6.112.1 | Rowpm600frs06PerfTelecomInputClientPast24StatHistoryPort1Entry | not-accessible | current | Row definition for the pm600frs06PerfTelecomInputClientPast24StatHistory table |
| 1.3.6.1.4.1.20044.115.11.6.112.1.1 | Columnpm600frs06PerfTelecomInputClientPast24StatHistoryPort1Index | read-only | current | Index definition for the pm600frs06PerfTelecomInputClientPast24StatHistory table |
| 1.3.6.1.4.1.20044.115.11.6.112.1.2 | Columnpm600frs06PerfTelecomInputClientPast24StatHistoryInvCvPort1 | read-only | current | Previous 24-hours EBC counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.112.1.3 | Columnpm600frs06PerfTelecomInputClientPast24StatHistoryCvValuePort1 | read-only | current | Previous 24-hours EBC counter :This OID gives the previous 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.115.11.6.112.1.4 | Columnpm600frs06PerfTelecomInputClientPast24StatHistoryInvEsPort1 | read-only | current | Previous 24-hours ES counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.112.1.5 | Columnpm600frs06PerfTelecomInputClientPast24StatHistoryEsValuePort1 | read-only | current | Previous 24-hours ES counter :This OID gives the previous 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.112.1.6 | Columnpm600frs06PerfTelecomInputClientPast24StatHistoryInvSesPort1 | read-only | current | Previous 24-hours SES counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.112.1.7 | Columnpm600frs06PerfTelecomInputClientPast24StatHistorySesValuePort1 | read-only | current | Previous 24-hours SES counter :This OID gives the previous 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.112.1.8 | Columnpm600frs06PerfTelecomInputClientPast24StatHistoryInvSefsPort1 | read-only | current | Previous 24-hours SEFS counter inv. :This OID indicates that the previous 24-hours severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.112.1.9 | Columnpm600frs06PerfTelecomInputClientPast24StatHistorySefsValuePort1 | read-only | current | Previous 24-hours SEFS counter :This OID gives the previous 24-hours severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.112.1.10 | Columnpm600frs06PerfTelecomInputClientPast24StatHistoryInvUasPort1 | read-only | current | Previous 24-hours UAS counter inv. :This OID indicates that the previous 24-hours UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.112.1.11 | Columnpm600frs06PerfTelecomInputClientPast24StatHistoryUasValuePort1 | read-only | current | Previous 24-hours UAS counter :This OID gives the previous 24-hours UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.144 | Tablepm600frs06PerfTelecomOutputClientCurrent15StatTable | not-accessible | current | List of pm600frs06PerfTelecomOutputClientCurrent15Stat Article |
| 1.3.6.1.4.1.20044.115.11.6.144.1 | Rowpm600frs06PerfTelecomOutputClientCurrent15StatEntry | not-accessible | current | Row definition for the pm600frs06PerfTelecomOutputClientCurrent15Stat table |
| 1.3.6.1.4.1.20044.115.11.6.144.1.1 | Columnpm600frs06PerfTelecomOutputClientCurrent15StatIndex | read-only | current | Index definition for the pm600frs06PerfTelecomOutputClientCurrent15Stat table |
| 1.3.6.1.4.1.20044.115.11.6.144.1.2 | Columnpm600frs06PerfTelecomOutputClientCurrent15StatInvCvPortn | read-only | current | Current 15-min EBC counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.144.1.3 | Columnpm600frs06PerfTelecomOutputClientCurrent15StatCvValuePortn | read-only | current | Current 15-min EBC counter :This OID gives the current 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.115.11.6.144.1.4 | Columnpm600frs06PerfTelecomOutputClientCurrent15StatInvEsPortn | read-only | current | Current 15-min ES counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.144.1.5 | Columnpm600frs06PerfTelecomOutputClientCurrent15StatEsValuePortn | read-only | current | Current 15-min ES counter :This OID gives the current 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.144.1.6 | Columnpm600frs06PerfTelecomOutputClientCurrent15StatInvSesPortn | read-only | current | Current 15-min SES counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.144.1.7 | Columnpm600frs06PerfTelecomOutputClientCurrent15StatSesValuePortn | read-only | current | Current 15-min SES counter :This OID gives the current 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.144.1.8 | Columnpm600frs06PerfTelecomOutputClientCurrent15StatInvSefsPortn | read-only | current | Current 15-min SEFS counter inv. :This OID indicates that the current 15-min severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.144.1.9 | Columnpm600frs06PerfTelecomOutputClientCurrent15StatSefsValuePortn | read-only | current | Current 15-min SEFS counter :This OID gives the current 15-min severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.144.1.10 | Columnpm600frs06PerfTelecomOutputClientCurrent15StatInvUasPortn | read-only | current | Current 15-min UAS counter inv. :This OID indicates that the current 15-min UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.144.1.11 | Columnpm600frs06PerfTelecomOutputClientCurrent15StatUasValuePortn | read-only | current | Current 15-min UAS counter :This OID gives the current 15-min UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.176 | Tablepm600frs06PerfTelecomOutputClientPast15StatHistoryPort1Table | not-accessible | current | List of pm600frs06PerfTelecomOutputClientPast15StatHistory Article |
| 1.3.6.1.4.1.20044.115.11.6.176.1 | Rowpm600frs06PerfTelecomOutputClientPast15StatHistoryPort1Entry | not-accessible | current | Row definition for the pm600frs06PerfTelecomOutputClientPast15StatHistory table |
| 1.3.6.1.4.1.20044.115.11.6.176.1.1 | Columnpm600frs06PerfTelecomOutputClientPast15StatHistoryPort1Index | read-only | current | Index definition for the pm600frs06PerfTelecomOutputClientPast15StatHistory table |
| 1.3.6.1.4.1.20044.115.11.6.176.1.2 | Columnpm600frs06PerfTelecomOutputClientPast15StatHistoryInvCvPort1 | read-only | current | Previous 15-min EBC counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.176.1.3 | Columnpm600frs06PerfTelecomOutputClientPast15StatHistoryCvValuePort1 | read-only | current | Previous 15-min EBC counter :This OID gives the previous 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.115.11.6.176.1.4 | Columnpm600frs06PerfTelecomOutputClientPast15StatHistoryInvEsPort1 | read-only | current | Previous 15-min ES counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.176.1.5 | Columnpm600frs06PerfTelecomOutputClientPast15StatHistoryEsValuePort1 | read-only | current | Previous 15-min ES counter :This OID gives the previous 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.176.1.6 | Columnpm600frs06PerfTelecomOutputClientPast15StatHistoryInvSesPort1 | read-only | current | Previous 15-min SES counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.176.1.7 | Columnpm600frs06PerfTelecomOutputClientPast15StatHistorySesValuePort1 | read-only | current | Previous 15-min SES counter :This OID gives the previous 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.176.1.8 | Columnpm600frs06PerfTelecomOutputClientPast15StatHistoryInvSefsPort1 | read-only | current | Previous 15-min SEFS counter inv. :This OID indicates that the previous 15-min severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.176.1.9 | Columnpm600frs06PerfTelecomOutputClientPast15StatHistorySefsValuePort1 | read-only | current | Previous 15-min SEFS counter :This OID gives the previous 15-min severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.176.1.10 | Columnpm600frs06PerfTelecomOutputClientPast15StatHistoryInvUasPort1 | read-only | current | Previous 15-min UAS counter inv. :This OID indicates that the previous 15-min UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.176.1.11 | Columnpm600frs06PerfTelecomOutputClientPast15StatHistoryUasValuePort1 | read-only | current | Previous 15-min UAS counter :This OID gives the previous 15-min UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.208 | Tablepm600frs06PerfTelecomOutputClientCurrent24StatTable | not-accessible | current | List of pm600frs06PerfTelecomOutputClientCurrent24Stat Article |
| 1.3.6.1.4.1.20044.115.11.6.208.1 | Rowpm600frs06PerfTelecomOutputClientCurrent24StatEntry | not-accessible | current | Row definition for the pm600frs06PerfTelecomOutputClientCurrent24Stat table |
| 1.3.6.1.4.1.20044.115.11.6.208.1.1 | Columnpm600frs06PerfTelecomOutputClientCurrent24StatIndex | read-only | current | Index definition for the pm600frs06PerfTelecomOutputClientCurrent24Stat table |
| 1.3.6.1.4.1.20044.115.11.6.208.1.2 | Columnpm600frs06PerfTelecomOutputClientCurrent24StatInvCvPortn | read-only | current | Current 24-hours EBC counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.208.1.3 | Columnpm600frs06PerfTelecomOutputClientCurrent24StatCvValuePortn | read-only | current | Current 24-hours EBC counter :This OID gives the current 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.115.11.6.208.1.4 | Columnpm600frs06PerfTelecomOutputClientCurrent24StatInvEsPortn | read-only | current | Current 24-hours ES counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.208.1.5 | Columnpm600frs06PerfTelecomOutputClientCurrent24StatEsValuePortn | read-only | current | Current 24-hours ES counter :This OID gives the current 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.208.1.6 | Columnpm600frs06PerfTelecomOutputClientCurrent24StatInvSesPortn | read-only | current | Current 24-hours SES counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.208.1.7 | Columnpm600frs06PerfTelecomOutputClientCurrent24StatSesValuePortn | read-only | current | Current 24-hours SES counter :This OID gives the current 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.208.1.8 | Columnpm600frs06PerfTelecomOutputClientCurrent24StatInvSefsPortn | read-only | current | Current 24-hours SEFS counter inv. :This OID indicates that the current 24-hours severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.208.1.9 | Columnpm600frs06PerfTelecomOutputClientCurrent24StatSefsValuePortn | read-only | current | Current 24-hours SEFS counter :This OID gives the current 24-hours severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.208.1.10 | Columnpm600frs06PerfTelecomOutputClientCurrent24StatInvUasPortn | read-only | current | Current 24-hours UAS counter inv. :This OID indicates that the current 24-hours UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.208.1.11 | Columnpm600frs06PerfTelecomOutputClientCurrent24StatUasValuePortn | read-only | current | Current 24-hours UAS counter :This OID gives the current 24-hours UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.240 | Tablepm600frs06PerfTelecomOutputClientPast24StatHistoryPort1Table | not-accessible | current | List of pm600frs06PerfTelecomOutputClientPast24StatHistory Article |
| 1.3.6.1.4.1.20044.115.11.6.240.1 | Rowpm600frs06PerfTelecomOutputClientPast24StatHistoryPort1Entry | not-accessible | current | Row definition for the pm600frs06PerfTelecomOutputClientPast24StatHistory table |
| 1.3.6.1.4.1.20044.115.11.6.240.1.1 | Columnpm600frs06PerfTelecomOutputClientPast24StatHistoryPort1Index | read-only | current | Index definition for the pm600frs06PerfTelecomOutputClientPast24StatHistory table |
| 1.3.6.1.4.1.20044.115.11.6.240.1.2 | Columnpm600frs06PerfTelecomOutputClientPast24StatHistoryInvCvPort1 | read-only | current | Previous 24-hours EBC counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.240.1.3 | Columnpm600frs06PerfTelecomOutputClientPast24StatHistoryCvValuePort1 | read-only | current | Previous 24-hours EBC counter :This OID gives the previous 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.115.11.6.240.1.4 | Columnpm600frs06PerfTelecomOutputClientPast24StatHistoryInvEsPort1 | read-only | current | Previous 24-hours ES counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.240.1.5 | Columnpm600frs06PerfTelecomOutputClientPast24StatHistoryEsValuePort1 | read-only | current | Previous 24-hours ES counter :This OID gives the previous 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.240.1.6 | Columnpm600frs06PerfTelecomOutputClientPast24StatHistoryInvSesPort1 | read-only | current | Previous 24-hours SES counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.240.1.7 | Columnpm600frs06PerfTelecomOutputClientPast24StatHistorySesValuePort1 | read-only | current | Previous 24-hours SES counter :This OID gives the previous 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.240.1.8 | Columnpm600frs06PerfTelecomOutputClientPast24StatHistoryInvSefsPort1 | read-only | current | Previous 24-hours SEFS counter inv. :This OID indicates that the previous 24-hours severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.240.1.9 | Columnpm600frs06PerfTelecomOutputClientPast24StatHistorySefsValuePort1 | read-only | current | Previous 24-hours SEFS counter :This OID gives the previous 24-hours severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.240.1.10 | Columnpm600frs06PerfTelecomOutputClientPast24StatHistoryInvUasPort1 | read-only | current | Previous 24-hours UAS counter inv. :This OID indicates that the previous 24-hours UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.240.1.11 | Columnpm600frs06PerfTelecomOutputClientPast24StatHistoryUasValuePort1 | read-only | current | Previous 24-hours UAS counter :This OID gives the previous 24-hours UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.115.11.6.848 | Tablepm600frs06PerfDatacomClientCurrent15StatTable | not-accessible | current | List of pm600frs06PerfDatacomClientCurrent15Stat Article |
| 1.3.6.1.4.1.20044.115.11.6.848.1 | Rowpm600frs06PerfDatacomClientCurrent15StatEntry | not-accessible | current | Row definition for the pm600frs06PerfDatacomClientCurrent15Stat table |
| 1.3.6.1.4.1.20044.115.11.6.848.1.1 | Columnpm600frs06PerfDatacomClientCurrent15StatIndex | read-only | current | Index definition for the pm600frs06PerfDatacomClientCurrent15Stat table |
| 1.3.6.1.4.1.20044.115.11.6.848.1.4 | Columnpm600frs06perfdatacomclientCurrent15StatInCrcCountInvPortn | read-only | current | Client Current 15-min Input CRC counter inv. :This OID indicates that the current 15-min Input CRC counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.848.1.5 | Columnpm600frs06perfdatacomclientCurrent15StatInCrcCountPortn | read-only | current | Client Current 15-min Input CRC counter :This OID gives the current 15-min Input CRC counter value |
| 1.3.6.1.4.1.20044.115.11.6.848.1.6 | Columnpm600frs06perfdatacomclientCurrent15StatInPacketCountInvPortn | read-only | current | Client Current 15-min Input Packet counter inv. :This OID indicates that the current 15-min Input Packet counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.848.1.7 | Columnpm600frs06perfdatacomclientCurrent15StatInPacketCountPortn | read-only | current | Client Current 15-min Input Packet counter :This OID gives the current 15-min Input Packet counter value |
| 1.3.6.1.4.1.20044.115.11.6.848.1.28 | Columnpm600frs06perfdatacomclientCurrent15StatOutCrcCountInvPortn | read-only | current | Client Current 15-min Output CRC counter inv. :This OID indicates that the current 15-min Output CRC counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.848.1.29 | Columnpm600frs06perfdatacomclientCurrent15StatOutCrcCountPortn | read-only | current | Client Current 15-min Output CRC counter :This OID gives the current 15-min Output CRC counter value |
| 1.3.6.1.4.1.20044.115.11.6.848.1.30 | Columnpm600frs06perfdatacomclientCurrent15StatOutPacketCountInvPortn | read-only | current | Client Current 15-min Output Packet counter inv. :This OID indicates that the current 15-min Output Packets counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.848.1.31 | Columnpm600frs06perfdatacomclientCurrent15StatOutPacketCountPortn | read-only | current | Client Current 15-min Output Packet counter :This OID gives the current 15-min Output Packets counter value |
| 1.3.6.1.4.1.20044.115.11.6.880 | Tablepm600frs06PerfDatacomClientPast15StatHistoryPort1Table | not-accessible | current | List of pm600frs06PerfDatacomClientPast15StatHistory Article |
| 1.3.6.1.4.1.20044.115.11.6.880.1 | Rowpm600frs06PerfDatacomClientPast15StatHistoryPort1Entry | not-accessible | current | Row definition for the pm600frs06PerfDatacomClientPast15StatHistory table |
| 1.3.6.1.4.1.20044.115.11.6.880.1.1 | Columnpm600frs06PerfDatacomClientPast15StatHistoryPort1Index | read-only | current | Index definition for the pm600frs06PerfDatacomClientPast15StatHistory table |
| 1.3.6.1.4.1.20044.115.11.6.880.1.4 | Columnpm600frs06perfdatacomclientPast15StatInCrcCountInvPort1 | read-only | current | Client Past 15-min Input CRC counter inv. :This OID indicates that the past 15-min Input CRC counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.880.1.5 | Columnpm600frs06perfdatacomclientPast15StatInCrcCountPort1 | read-only | current | Client Past 15-min Input CRC counter :This OID gives the past 15-min Input CRC counter value |
| 1.3.6.1.4.1.20044.115.11.6.880.1.6 | Columnpm600frs06perfdatacomclientPast15StatInPacketCountInvPort1 | read-only | current | Client Past 15-min Input Packet counter inv. :This OID indicates that the past 15-min Input Packet counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.880.1.7 | Columnpm600frs06perfdatacomclientPast15StatInPacketCountPort1 | read-only | current | Client Past 15-min Input Packet counter :This OID gives the past 15-min Input Packet counter value |
| 1.3.6.1.4.1.20044.115.11.6.880.1.28 | Columnpm600frs06perfdatacomclientPast15StatOutCrcCountInvPort1 | read-only | current | Client Past 15-min Output CRC counter inv. :This OID indicates that the past 15-min Output CRC counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.880.1.29 | Columnpm600frs06perfdatacomclientPast15StatOutCrcCountPort1 | read-only | current | Client Past 15-min Output CRC counter :This OID gives the past 15-min Output CRC counter value |
| 1.3.6.1.4.1.20044.115.11.6.880.1.30 | Columnpm600frs06perfdatacomclientPast15StatOutPacketCountInvPort1 | read-only | current | Client Past 15-min Output Packet counter inv. :This OID indicates that the past 15-min Output Packets counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.880.1.31 | Columnpm600frs06perfdatacomclientPast15StatOutPacketCountPort1 | read-only | current | Client Past 15-min Output Packet counter :This OID gives the past 15-min Output Packets counter value |
| 1.3.6.1.4.1.20044.115.11.6.912 | Tablepm600frs06PerfDatacomClientCurrent24StatTable | not-accessible | current | List of pm600frs06PerfDatacomClientCurrent24Stat Article |
| 1.3.6.1.4.1.20044.115.11.6.912.1 | Rowpm600frs06PerfDatacomClientCurrent24StatEntry | not-accessible | current | Row definition for the pm600frs06PerfDatacomClientCurrent24Stat table |
| 1.3.6.1.4.1.20044.115.11.6.912.1.1 | Columnpm600frs06PerfDatacomClientCurrent24StatIndex | read-only | current | Index definition for the pm600frs06PerfDatacomClientCurrent24Stat table |
| 1.3.6.1.4.1.20044.115.11.6.912.1.4 | Columnpm600frs06perfdatacomclientCurrent24StatInCrcCountInvPortn | read-only | current | Client Current 24-hours Input CRC counter inv. :This OID indicates that the current 24-hours Input CRC counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.912.1.5 | Columnpm600frs06perfdatacomclientCurrent24StatInCrcCountPortn | read-only | current | Client Current 24-hours Input CRC counter :This OID gives the current 24-hours Input CRC counter value |
| 1.3.6.1.4.1.20044.115.11.6.912.1.6 | Columnpm600frs06perfdatacomclientCurrent24StatInPacketCountInvPortn | read-only | current | Client Current 24-hours Input Packet counter inv. :This OID indicates that the current 24-hours Input Packet counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.912.1.7 | Columnpm600frs06perfdatacomclientCurrent24StatInPacketCountPortn | read-only | current | Client Current 24-hours Input Packet counter :This OID gives the current 24-hours Input Packet counter value |
| 1.3.6.1.4.1.20044.115.11.6.912.1.28 | Columnpm600frs06perfdatacomclientCurrent24StatOutCrcCountInvPortn | read-only | current | Client Current 24-hours Output CRC counter inv. :This OID indicates that the current 24-hours Output CRC counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.912.1.29 | Columnpm600frs06perfdatacomclientCurrent24StatOutCrcCountPortn | read-only | current | Client Current 24-hours Output CRC counter :This OID gives the current 24-hours Output CRC counter value |
| 1.3.6.1.4.1.20044.115.11.6.912.1.30 | Columnpm600frs06perfdatacomclientCurrent24StatOutPacketCountInvPortn | read-only | current | Client Current 24-hours Output Packet counter inv. :This OID indicates that the current 24-hours Output Packets counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.912.1.31 | Columnpm600frs06perfdatacomclientCurrent24StatOutPacketCountPortn | read-only | current | Client Current 24-hours Output Packet counter :This OID gives the current 24-hours Output Packets counter value |
| 1.3.6.1.4.1.20044.115.11.6.944 | Tablepm600frs06PerfDatacomClientPast24StatHistoryPort1Table | not-accessible | current | List of pm600frs06PerfDatacomClientPast24StatHistory Article |
| 1.3.6.1.4.1.20044.115.11.6.944.1 | Rowpm600frs06PerfDatacomClientPast24StatHistoryPort1Entry | not-accessible | current | Row definition for the pm600frs06PerfDatacomClientPast24StatHistory table |
| 1.3.6.1.4.1.20044.115.11.6.944.1.1 | Columnpm600frs06PerfDatacomClientPast24StatHistoryPort1Index | read-only | current | Index definition for the pm600frs06PerfDatacomClientPast24StatHistory table |
| 1.3.6.1.4.1.20044.115.11.6.944.1.4 | Columnpm600frs06perfdatacomclientPast24StatInCrcCountInvPort1 | read-only | current | Client Past 24-hours Input CRC counter inv. :This OID indicates that the past 24-hours Input CRC counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.944.1.5 | Columnpm600frs06perfdatacomclientPast24StatInCrcCountPort1 | read-only | current | Client Past 24-hours Input CRC counter :This OID gives the past 24-hours Input CRC counter value |
| 1.3.6.1.4.1.20044.115.11.6.944.1.6 | Columnpm600frs06perfdatacomclientPast24StatInPacketCountInvPort1 | read-only | current | Client Past 24-hours Input Packet counter inv. :This OID indicates that the past 24-hours Input Packet counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.944.1.7 | Columnpm600frs06perfdatacomclientPast24StatInPacketCountPort1 | read-only | current | Client Past 24-hours Input Packet counter :This OID gives the past 24-hours Input Packet counter value |
| 1.3.6.1.4.1.20044.115.11.6.944.1.28 | Columnpm600frs06perfdatacomclientPast24StatOutCrcCountInvPort1 | read-only | current | Client Past 24-hours Output CRC counter inv. :This OID indicates that the past 24-hours Output CRC counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.944.1.29 | Columnpm600frs06perfdatacomclientPast24StatOutCrcCountPort1 | read-only | current | Client Past 24-hours Output CRC counter :This OID gives the past 24-hours Output CRC counter value |
| 1.3.6.1.4.1.20044.115.11.6.944.1.30 | Columnpm600frs06perfdatacomclientPast24StatOutPacketCountInvPort1 | read-only | current | Client Past 24-hours Output Packet counter inv. :This OID indicates that the past 24-hours Output Packets counter is invalid |
| 1.3.6.1.4.1.20044.115.11.6.944.1.31 | Columnpm600frs06perfdatacomclientPast24StatOutPacketCountPort1 | read-only | current | Client Past 24-hours Output Packet counter :This OID gives the past 24-hours Output Packets counter value |
| 1.3.6.1.4.1.20044.115.11.7 | Nodepm600frs06MonPerfLine | |||
| 1.3.6.1.4.1.20044.115.11.7.336 | Tablepm600frs06PerfTelecomLinePostFecCurrent15StatTable | not-accessible | current | List of pm600frs06PerfTelecomLinePostFecCurrent15Stat Article |
| 1.3.6.1.4.1.20044.115.11.7.336.1 | Rowpm600frs06PerfTelecomLinePostFecCurrent15StatEntry | not-accessible | current | Row definition for the pm600frs06PerfTelecomLinePostFecCurrent15Stat table |
| 1.3.6.1.4.1.20044.115.11.7.336.1.1 | Columnpm600frs06PerfTelecomLinePostFecCurrent15StatIndex | read-only | current | Index definition for the pm600frs06PerfTelecomLinePostFecCurrent15Stat table |
| 1.3.6.1.4.1.20044.115.11.7.336.1.2 | Columnpm600frs06PerfTelecomLinePostFecCurrent15StatInvCvPortn | read-only | current | Current 15-min EBC counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.336.1.3 | Columnpm600frs06PerfTelecomLinePostFecCurrent15StatCvValuePortn | read-only | current | Current 15-min EBC counter :This OID gives the current 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.115.11.7.336.1.4 | Columnpm600frs06PerfTelecomLinePostFecCurrent15StatInvEsPortn | read-only | current | Current 15-min ES counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.336.1.5 | Columnpm600frs06PerfTelecomLinePostFecCurrent15StatEsValuePortn | read-only | current | Current 15-min ES counter :This OID gives the current 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.115.11.7.336.1.6 | Columnpm600frs06PerfTelecomLinePostFecCurrent15StatInvSesPortn | read-only | current | Current 15-min SES counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.336.1.7 | Columnpm600frs06PerfTelecomLinePostFecCurrent15StatSesValuePortn | read-only | current | Current 15-min SES counter :This OID gives the current 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.115.11.7.336.1.8 | Columnpm600frs06PerfTelecomLinePostFecCurrent15StatInvSefsPortn | read-only | current | Current 15-min SEFS counter inv. :This OID indicates that the current 15-min severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.336.1.9 | Columnpm600frs06PerfTelecomLinePostFecCurrent15StatSefsValuePortn | read-only | current | Current 15-min SEFS counter :This OID gives the current 15-min severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.115.11.7.336.1.10 | Columnpm600frs06PerfTelecomLinePostFecCurrent15StatInvUasPortn | read-only | current | Current 15-min UAS counter inv. :This OID indicates that the current 15-min UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.336.1.11 | Columnpm600frs06PerfTelecomLinePostFecCurrent15StatUasValuePortn | read-only | current | Current 15-min UAS counter :This OID gives the current 15-min UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.115.11.7.337 | Tablepm600frs06PerfTelecomLinePostFecPast15StatHistoryPort1Table | not-accessible | current | List of pm600frs06PerfTelecomLinePostFecPast15StatHistory Article |
| 1.3.6.1.4.1.20044.115.11.7.337.1 | Rowpm600frs06PerfTelecomLinePostFecPast15StatHistoryPort1Entry | not-accessible | current | Row definition for the pm600frs06PerfTelecomLinePostFecPast15StatHistory table |
| 1.3.6.1.4.1.20044.115.11.7.337.1.1 | Columnpm600frs06PerfTelecomLinePostFecPast15StatHistoryPort1Index | read-only | current | Index definition for the pm600frs06PerfTelecomLinePostFecPast15StatHistory table |
| 1.3.6.1.4.1.20044.115.11.7.337.1.2 | Columnpm600frs06PerfTelecomLinePostFecPast15StatHistoryInvCvPort1 | read-only | current | Previous 15-min EBC counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.337.1.3 | Columnpm600frs06PerfTelecomLinePostFecPast15StatHistoryCvValuePort1 | read-only | current | Previous 15-min EBC counter :This OID gives the previous 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.115.11.7.337.1.4 | Columnpm600frs06PerfTelecomLinePostFecPast15StatHistoryInvEsPort1 | read-only | current | Previous 15-min ES counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.337.1.5 | Columnpm600frs06PerfTelecomLinePostFecPast15StatHistoryEsValuePort1 | read-only | current | Previous 15-min ES counter :This OID gives the previous 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.115.11.7.337.1.6 | Columnpm600frs06PerfTelecomLinePostFecPast15StatHistoryInvSesPort1 | read-only | current | Previous 15-min SES counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.337.1.7 | Columnpm600frs06PerfTelecomLinePostFecPast15StatHistorySesValuePort1 | read-only | current | Previous 15-min SES counter :This OID gives the previous 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.115.11.7.337.1.8 | Columnpm600frs06PerfTelecomLinePostFecPast15StatHistoryInvSefsPort1 | read-only | current | Previous 15-min SEFS counter inv. :This OID indicates that the previous 15-min severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.337.1.9 | Columnpm600frs06PerfTelecomLinePostFecPast15StatHistorySefsValuePort1 | read-only | current | Previous 15-min SEFS counter :This OID gives the previous 15-min severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.115.11.7.337.1.10 | Columnpm600frs06PerfTelecomLinePostFecPast15StatHistoryInvUasPort1 | read-only | current | Previous 15-min UAS counter inv. :This OID indicates that the previous 15-min UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.337.1.11 | Columnpm600frs06PerfTelecomLinePostFecPast15StatHistoryUasValuePort1 | read-only | current | Previous 15-min UAS counter :This OID gives the previous 15-min UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.115.11.7.338 | Tablepm600frs06PerfTelecomLinePostFecCurrent24StatTable | not-accessible | current | List of pm600frs06PerfTelecomLinePostFecCurrent24Stat Article |
| 1.3.6.1.4.1.20044.115.11.7.338.1 | Rowpm600frs06PerfTelecomLinePostFecCurrent24StatEntry | not-accessible | current | Row definition for the pm600frs06PerfTelecomLinePostFecCurrent24Stat table |
| 1.3.6.1.4.1.20044.115.11.7.338.1.1 | Columnpm600frs06PerfTelecomLinePostFecCurrent24StatIndex | read-only | current | Index definition for the pm600frs06PerfTelecomLinePostFecCurrent24Stat table |
| 1.3.6.1.4.1.20044.115.11.7.338.1.2 | Columnpm600frs06PerfTelecomLinePostFecCurrent24StatInvCvPortn | read-only | current | Current 24-hours EBC counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.338.1.3 | Columnpm600frs06PerfTelecomLinePostFecCurrent24StatCvValuePortn | read-only | current | Current 24-hours EBC counter :This OID gives the current 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.115.11.7.338.1.4 | Columnpm600frs06PerfTelecomLinePostFecCurrent24StatInvEsPortn | read-only | current | Current 24-hours ES counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.338.1.5 | Columnpm600frs06PerfTelecomLinePostFecCurrent24StatEsValuePortn | read-only | current | Current 24-hours ES counter :This OID gives the current 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.115.11.7.338.1.6 | Columnpm600frs06PerfTelecomLinePostFecCurrent24StatInvSesPortn | read-only | current | Current 24-hours SES counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.338.1.7 | Columnpm600frs06PerfTelecomLinePostFecCurrent24StatSesValuePortn | read-only | current | Current 24-hours SES counter :This OID gives the current 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.115.11.7.338.1.8 | Columnpm600frs06PerfTelecomLinePostFecCurrent24StatInvSefsPortn | read-only | current | Current 24-hours SEFS counter inv. :This OID indicates that the current 24-hours severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.338.1.9 | Columnpm600frs06PerfTelecomLinePostFecCurrent24StatSefsValuePortn | read-only | current | Current 24-hours SEFS counter :This OID gives the current 24-hours severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.115.11.7.338.1.10 | Columnpm600frs06PerfTelecomLinePostFecCurrent24StatInvUasPortn | read-only | current | Current 24-hours UAS counter inv. :This OID indicates that the current 24-hours UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.338.1.11 | Columnpm600frs06PerfTelecomLinePostFecCurrent24StatUasValuePortn | read-only | current | Current 24-hours UAS counter :This OID gives the current 24-hours UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.115.11.7.339 | Tablepm600frs06PerfTelecomLinePostFecPast24StatHistoryPort1Table | not-accessible | current | List of pm600frs06PerfTelecomLinePostFecPast24StatHistory Article |
| 1.3.6.1.4.1.20044.115.11.7.339.1 | Rowpm600frs06PerfTelecomLinePostFecPast24StatHistoryPort1Entry | not-accessible | current | Row definition for the pm600frs06PerfTelecomLinePostFecPast24StatHistory table |
| 1.3.6.1.4.1.20044.115.11.7.339.1.1 | Columnpm600frs06PerfTelecomLinePostFecPast24StatHistoryPort1Index | read-only | current | Index definition for the pm600frs06PerfTelecomLinePostFecPast24StatHistory table |
| 1.3.6.1.4.1.20044.115.11.7.339.1.2 | Columnpm600frs06PerfTelecomLinePostFecPast24StatHistoryInvCvPort1 | read-only | current | Previous 24-hours EBC counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.339.1.3 | Columnpm600frs06PerfTelecomLinePostFecPast24StatHistoryCvValuePort1 | read-only | current | Previous 24-hours EBC counter :This OID gives the previous 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.115.11.7.339.1.4 | Columnpm600frs06PerfTelecomLinePostFecPast24StatHistoryInvEsPort1 | read-only | current | Previous 24-hours ES counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.339.1.5 | Columnpm600frs06PerfTelecomLinePostFecPast24StatHistoryEsValuePort1 | read-only | current | Previous 24-hours ES counter :This OID gives the previous 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.115.11.7.339.1.6 | Columnpm600frs06PerfTelecomLinePostFecPast24StatHistoryInvSesPort1 | read-only | current | Previous 24-hours SES counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.339.1.7 | Columnpm600frs06PerfTelecomLinePostFecPast24StatHistorySesValuePort1 | read-only | current | Previous 24-hours SES counter :This OID gives the previous 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.115.11.7.339.1.8 | Columnpm600frs06PerfTelecomLinePostFecPast24StatHistoryInvSefsPort1 | read-only | current | Previous 24-hours SEFS counter inv. :This OID indicates that the previous 24-hours severely Errored Framing Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.339.1.9 | Columnpm600frs06PerfTelecomLinePostFecPast24StatHistorySefsValuePort1 | read-only | current | Previous 24-hours SEFS counter :This OID gives the previous 24-hours severely Errored Framing Second counter value |
| 1.3.6.1.4.1.20044.115.11.7.339.1.10 | Columnpm600frs06PerfTelecomLinePostFecPast24StatHistoryInvUasPort1 | read-only | current | Previous 24-hours UAS counter inv. :This OID indicates that the previous 24-hours UnAvailable Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.339.1.11 | Columnpm600frs06PerfTelecomLinePostFecPast24StatHistoryUasValuePort1 | read-only | current | Previous 24-hours UAS counter :This OID gives the previous 24-hours UnAvailable Second counter value |
| 1.3.6.1.4.1.20044.115.11.7.352 | Tablepm600frs06PerfTelecomBerLinePreFecCurrent15StatTable | not-accessible | current | List of pm600frs06PerfTelecomBerLinePreFecCurrent15Stat Article |
| 1.3.6.1.4.1.20044.115.11.7.352.1 | Rowpm600frs06PerfTelecomBerLinePreFecCurrent15StatEntry | not-accessible | current | Row definition for the pm600frs06PerfTelecomBerLinePreFecCurrent15Stat table |
| 1.3.6.1.4.1.20044.115.11.7.352.1.1 | Columnpm600frs06PerfTelecomBerLinePreFecCurrent15StatIndex | read-only | current | Index definition for the pm600frs06PerfTelecomBerLinePreFecCurrent15Stat table |
| 1.3.6.1.4.1.20044.115.11.7.352.1.2 | Columnpm600frs06PerfTelecomBerLinePreFecCurrent15StatInvBerPortn | read-only | current | Current 15-min BER counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.352.1.3 | Columnpm600frs06PerfTelecomBerLinePreFecCurrent15StatBerValuePortn | read-only | current | Current 15-min BER counter :This OID gives the current 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.115.11.7.352.1.4 | Columnpm600frs06PerfTelecomBerLinePreFecCurrent15StatInvMinBerPortn | read-only | current | Current 15-min MinBER counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.352.1.5 | Columnpm600frs06PerfTelecomBerLinePreFecCurrent15StatMinBerValuePortn | read-only | current | Current 15-min MinBER counter :This OID gives the current 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.115.11.7.352.1.6 | Columnpm600frs06PerfTelecomBerLinePreFecCurrent15StatInvMaxBerPortn | read-only | current | Current 15-min MaxBER counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.352.1.7 | Columnpm600frs06PerfTelecomBerLinePreFecCurrent15StatMaxBerValuePortn | read-only | current | Current 15-min MaxBER counter :This OID gives the current 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.115.11.7.353 | Tablepm600frs06PerfTelecomBerLinePreFecPast15StatHistoryPort1Table | not-accessible | current | List of pm600frs06PerfTelecomBerLinePreFecPast15StatHistory Article |
| 1.3.6.1.4.1.20044.115.11.7.353.1 | Rowpm600frs06PerfTelecomBerLinePreFecPast15StatHistoryPort1Entry | not-accessible | current | Row definition for the pm600frs06PerfTelecomBerLinePreFecPast15StatHistory table |
| 1.3.6.1.4.1.20044.115.11.7.353.1.1 | Columnpm600frs06PerfTelecomBerLinePreFecPast15StatHistoryPort1Index | read-only | current | Index definition for the pm600frs06PerfTelecomBerLinePreFecPast15StatHistory table |
| 1.3.6.1.4.1.20044.115.11.7.353.1.2 | Columnpm600frs06PerfTelecomBerLinePreFecPast15StatHistoryInvBerPort1 | read-only | current | Previous 15-min BER counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.353.1.3 | Columnpm600frs06PerfTelecomBerLinePreFecPast15StatHistoryBerValuePort1 | read-only | current | Previous 15-min BER counter :This OID gives the previous 15-min Coding Violation counter value |
| 1.3.6.1.4.1.20044.115.11.7.353.1.4 | Columnpm600frs06PerfTelecomBerLinePreFecPast15StatHistoryInvMinBerPort1 | read-only | current | Previous 15-min MinBER counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.353.1.5 | Columnpm600frs06PerfTelecomBerLinePreFecPast15StatHistoryMinBerValuePort1 | read-only | current | Previous 15-min MinBER counter :This OID gives the previous 15-min Errored Second counter value |
| 1.3.6.1.4.1.20044.115.11.7.353.1.6 | Columnpm600frs06PerfTelecomBerLinePreFecPast15StatHistoryInvMaxBerPort1 | read-only | current | Previous 15-min MaxBER counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.353.1.7 | Columnpm600frs06PerfTelecomBerLinePreFecPast15StatHistoryMaxBerValuePort1 | read-only | current | Previous 15-min MaxBER counter :This OID gives the previous 15-min severely Errored Second counter value |
| 1.3.6.1.4.1.20044.115.11.7.354 | Tablepm600frs06PerfTelecomBerLinePreFecCurrent24StatTable | not-accessible | current | List of pm600frs06PerfTelecomBerLinePreFecCurrent24Stat Article |
| 1.3.6.1.4.1.20044.115.11.7.354.1 | Rowpm600frs06PerfTelecomBerLinePreFecCurrent24StatEntry | not-accessible | current | Row definition for the pm600frs06PerfTelecomBerLinePreFecCurrent24Stat table |
| 1.3.6.1.4.1.20044.115.11.7.354.1.1 | Columnpm600frs06PerfTelecomBerLinePreFecCurrent24StatIndex | read-only | current | Index definition for the pm600frs06PerfTelecomBerLinePreFecCurrent24Stat table |
| 1.3.6.1.4.1.20044.115.11.7.354.1.2 | Columnpm600frs06PerfTelecomBerLinePreFecCurrent24StatInvBerPortn | read-only | current | Current 24-hours BER counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.354.1.3 | Columnpm600frs06PerfTelecomBerLinePreFecCurrent24StatBerValuePortn | read-only | current | Current 24-hours BER counter :This OID gives the current 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.115.11.7.354.1.4 | Columnpm600frs06PerfTelecomBerLinePreFecCurrent24StatInvMinBerPortn | read-only | current | Current 24-hoursMinBER counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.354.1.5 | Columnpm600frs06PerfTelecomBerLinePreFecCurrent24StatMinBerValuePortn | read-only | current | Current 24-hours MinBER counter :This OID gives the current 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.115.11.7.354.1.6 | Columnpm600frs06PerfTelecomBerLinePreFecCurrent24StatInvMaxBerPortn | read-only | current | Current 24-hours MaxBER counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.354.1.7 | Columnpm600frs06PerfTelecomBerLinePreFecCurrent24StatMaxBerValuePortn | read-only | current | Current 24-hours MaxBER counter :This OID gives the current 24-hours severely Errored Second counter value |
| 1.3.6.1.4.1.20044.115.11.7.355 | Tablepm600frs06PerfTelecomBerLinePreFecPast24StatHistoryPort1Table | not-accessible | current | List of pm600frs06PerfTelecomBerLinePreFecPast24StatHistory Article |
| 1.3.6.1.4.1.20044.115.11.7.355.1 | Rowpm600frs06PerfTelecomBerLinePreFecPast24StatHistoryPort1Entry | not-accessible | current | Row definition for the pm600frs06PerfTelecomBerLinePreFecPast24StatHistory table |
| 1.3.6.1.4.1.20044.115.11.7.355.1.1 | Columnpm600frs06PerfTelecomBerLinePreFecPast24StatHistoryPort1Index | read-only | current | Index definition for the pm600frs06PerfTelecomBerLinePreFecPast24StatHistory table |
| 1.3.6.1.4.1.20044.115.11.7.355.1.2 | Columnpm600frs06PerfTelecomBerLinePreFecPast24StatHistoryInvBerPort1 | read-only | current | Previous 24-hours BER counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.355.1.3 | Columnpm600frs06PerfTelecomBerLinePreFecPast24StatHistoryBerValuePort1 | read-only | current | Previous 24-hours BER counter :This OID gives the previous 24-hours Coding Violation counter value |
| 1.3.6.1.4.1.20044.115.11.7.355.1.4 | Columnpm600frs06PerfTelecomBerLinePreFecPast24StatHistoryInvMinBerPort1 | read-only | current | Previous 24-hours MinBER counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.355.1.5 | Columnpm600frs06PerfTelecomBerLinePreFecPast24StatHistoryMinBerValuePort1 | read-only | current | Previous 24-hours MinBER counter :This OID gives the previous 24-hours Errored Second counter value |
| 1.3.6.1.4.1.20044.115.11.7.355.1.6 | Columnpm600frs06PerfTelecomBerLinePreFecPast24StatHistoryInvMaxBerPort1 | read-only | current | Previous 24-hours MaxBER counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid |
| 1.3.6.1.4.1.20044.115.11.7.355.1.7 | Columnpm600frs06PerfTelecomBerLinePreFecPast24StatHistoryMaxBerValuePort1 | read-only | current | Previous 24-hours MaxBER counter :This OID gives the previous 24-hours severely Errored Second counter value |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| Pm600frs06ClientBist | INTEGER { bistdisable(0), bisttxenable(1), bistrxEnable(2) } | current | Mode for BIST |
| Pm600frs06ClientModeA | INTEGER { clientmode4x100gbe(1), clientmode400gbe(2) } | current | Different values on the client mode |
| Pm600frs06ClientProtocolA | INTEGER { protocolclientotu4(1), protocolclient100gbe(2) } | current | Different values on the protocol on the client ports |
| Pm600frs06DccMode | INTEGER { dccOff(0), dccOn(1) } | current | Mode for DCC |
| Pm600frs06ModuleModeA | INTEGER { modulemodea100gulh(1008), modulemodea200glh(688), modulemodea400g(128) } | current | Different values on the module mode |
| Pm600frs06ModuleModeB | INTEGER { modulemodeb100gulh(1008), modulemodeb200glh(688), modulemodeb400gma(128), modulemodeb200gmr(609), modulemodeb300gmr(321), modulemodeb500gzr(1184), modulemodeb600gzr(1136) } | current | Different values on the module mode |
| Pm600frs06ModuleModeC | INTEGER { modulemodec100gulh(1008), modulemodec200glh(688), modulemodec200gmr(609), modulemodec300gmr(321), modulemodec400gma(128), modulemodec200gmrmaster(610), modulemodec200gmrslave (611), modulemodec200glhmaster(689), modulemodec200glhslave(690) } | current | Different values on the module mode |
| Pm600frs06OrxChannel | INTEGER | current | Channel selection on transceiver Rx line ports |
| Pm600frs06OtxChannel | INTEGER | current | Channel selection on transceiver Tx line ports |
| Pm600frs06OtxGrid | INTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50), otxgrid25(25) } | current | Different grids on OTX-TLH on client and line ports |