EKINOPS-Pm801RR-MIB

262 objects
MIB for the Ekinops Pm801RR hardware.
OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.48IdentitymodulePm801RRMIB for the Ekinops Pm801RR hardware.
1.3.6.1.4.1.20044.48.2Nodepm801rralarms
1.3.6.1.4.1.20044.48.2.1Nodepm801rrAlmOther
1.3.6.1.4.1.20044.48.2.1.1Nodepm801rrAlmOtherNurg
1.3.6.1.4.1.20044.48.2.1.2Nodepm801rrAlmOtherUrg
1.3.6.1.4.1.20044.48.2.1.3Nodepm801rrAlmOtherCrit
1.3.6.1.4.1.20044.48.2.1.3.0Nodepm801rrAlmsynthAlm0
1.3.6.1.4.1.20044.48.2.1.3.0.9Scalarpm801rrAlmModuleGlobFailureread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the PM <Condtype> MODULE_GLOB_FAILURE <Probcause> equipmentMalfunction (16) <Alarmty…
1.3.6.1.4.1.20044.48.2.1.3.0.15Scalarpm801rrAlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.48.2.1.3.0.16Scalarpm801rrAlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.48.2.2Nodepm801rrAlmClient
1.3.6.1.4.1.20044.48.2.2.1Nodepm801rrAlmClientNurg
1.3.6.1.4.1.20044.48.2.2.1.17Nodepm801rrAlmclientXfpWarnings
1.3.6.1.4.1.20044.48.2.2.1.17.1Scalarpm801rrAlmClientTxPwrLowWngread-onlycurrentLine 1 Optical Tx Power Low Warning :Warning indicating that the Line 1 XFP/OTX transmitter transmitter output power is lower than the threshold value written …
1.3.6.1.4.1.20044.48.2.2.1.17.2Scalarpm801rrAlmClientTxPwrHighWngread-onlycurrentLine 1 Optical Tx Power High Warning :Warning indicating that the Line 1 XFP/OTX transmitter transmitter output power is higher than the threshold value writte…
1.3.6.1.4.1.20044.48.2.2.1.17.3Scalarpm801rrAlmClientTxBiasLowWngread-onlycurrentLine 1 Transceiver Bias Low Warning :Warning indicating that the Line 1 XFP/OTX transmitter laser bias current is lower than the threshold value written in the…
1.3.6.1.4.1.20044.48.2.2.1.17.4Scalarpm801rrAlmClientTxBiasHighWngread-onlycurrentLine 1 Transceiver Bias High Warning :Warning indicating that the Line 1 XFP/OTX transmitter laser bias current is higher than the threshold value written in t…
1.3.6.1.4.1.20044.48.2.2.1.17.7Scalarpm801rrAlmClientTempLowWngread-onlycurrentLine 1 Transceiver Temp Low Warning :Warning indicating that the Line 1 XFP/OTX temperature is lower than the threshold value written in the Line 1 XFP/OTX EEP…
1.3.6.1.4.1.20044.48.2.2.1.17.8Scalarpm801rrAlmClientTempHighWngread-onlycurrentLine 1 Transceiver Temp High Warning :Warning indicating that the Line 1 XFP/OTX temperature is higher than the threshold value written in the Line 1 XFP/OTX E…
1.3.6.1.4.1.20044.48.2.2.1.17.15Scalarpm801rrAlmClientRxPwrLowWngread-onlycurrentLine 1 Optical Rx Power Low Warning :Warning indicating that the Line 1 XFP/OTX received optical power is lower than the threshold value written in the Line 1 …
1.3.6.1.4.1.20044.48.2.2.1.17.16Scalarpm801rrAlmClientRxPwrHighWngread-onlycurrentLine 1 Optical Rx Power High Warning :Warning indicating that the Line 1 XFP/OTX received optical power is higher than the threshold value written in the Line …
1.3.6.1.4.1.20044.48.2.2.1.23Nodepm801rrAlmclientOtxTlhWarnings
1.3.6.1.4.1.20044.48.2.2.1.23.5Scalarpm801rrAlmClientModulatorAgingHighWarningread-onlycurrentLine 1 Modulator Aging High Warning :Warning indicating the Line 1 OTX TLH modulator aging is higher than the threshold written in the EEPROM <Condtype> CLIENT…
1.3.6.1.4.1.20044.48.2.2.1.23.6Scalarpm801rrAlmClientAgingHighWarningread-onlycurrentLine 1 OTX TLH Aging High Warning :Warning indicating the Line 1 OTX TLH aging is higher than the threshold written in the EEPROM <Condtype> CLIENT_AGING_HIGH_…
1.3.6.1.4.1.20044.48.2.2.1.23.12Scalarpm801rrAlmClientFreqDevHighWarningread-onlycurrentLine 1 Freq. Deviation High Warning :Warning indicating the Line 1 OTX TLH frequency deviation is higher than the threshold written in the EEPROM <Condtype> CL…
1.3.6.1.4.1.20044.48.2.2.1.23.14Scalarpm801rrAlmClientLaserTempHighWarningread-onlycurrentLine 1 Laser Temp. High Warning :Warning indicating the Line 1 OTX TLH laser temperature is higher than the threshold written in the EEPROM <Condtype> CLIENT_L…
1.3.6.1.4.1.20044.48.2.2.2Nodepm801rrAlmClientUrg
1.3.6.1.4.1.20044.48.2.2.2.16Nodepm801rrAlmclientXfpAlarm1
1.3.6.1.4.1.20044.48.2.2.2.16.1Scalarpm801rrAlmClientTxPwrLowAlaread-onlycurrentLine 1 Optical Tx Power Low :Alarm indicating that the Line 1 XFP/OTX transmitter transmitter output power is lower than the threshold value written in the Lin…
1.3.6.1.4.1.20044.48.2.2.2.16.2Scalarpm801rrAlmClientTxPwrHighAlaread-onlycurrentLine 1 Optical Tx Power High :Alarm indicating that the Line 1 XFP/OTX transmitter transmitter output power is higher than the threshold value written in the L…
1.3.6.1.4.1.20044.48.2.2.2.16.3Scalarpm801rrAlmClientTxBiasLowAlaread-onlycurrentLine 1 Transceiver Bias Low :Alarm indicating that the Line 1 XFP/OTX transmitter laser bias current is lower than the threshold value written in the Line 1 XF…
1.3.6.1.4.1.20044.48.2.2.2.16.4Scalarpm801rrAlmClientTxBiasHighAlaread-onlycurrentLine 1 Transceiver Bias High :Alarm indicating that the Line 1 XFP/OTX transmitter laser bias current is higher than the threshold value written in the Line 1 …
1.3.6.1.4.1.20044.48.2.2.2.16.7Scalarpm801rrAlmClientTempLowAlaread-onlycurrentLine 1 Transceiver Temp Low :Alarm indicating that the Line 1 XFP/OTX temperature is lower than the threshold value written in the Line 1 XFP/OTX EEPROM <Condt…
1.3.6.1.4.1.20044.48.2.2.2.16.8Scalarpm801rrAlmClientTempHighAlaread-onlycurrentLine 1 Transceiver Temp High :Alarm indicating that the Line 1 XFP/OTX temperature is higher than the threshold value written in the Line 1 XFP/OTX EEPROM <Con…
1.3.6.1.4.1.20044.48.2.2.2.16.15Scalarpm801rrAlmClientRxPwrLowAlaread-onlycurrentLine 1 Optical Rx Power Low :Alarm indicating that the Line 1 XFP/OTX received optical power is lower than the threshold value written in the Line 1 XFP/OTX EE…
1.3.6.1.4.1.20044.48.2.2.2.16.16Scalarpm801rrAlmClientRxPwrHighAlaread-onlycurrentLine 1 Optical Rx Power High :Alarm indicating that the Line 1 XFP/OTX received optical power is higher than the threshold value written in the Line 1 XFP/OTX …
1.3.6.1.4.1.20044.48.2.2.2.22Nodepm801rrAlmclientOtxTlhAlarms3
1.3.6.1.4.1.20044.48.2.2.2.22.5Scalarpm801rrAlmClientModulatorAgingHighAlaread-onlycurrentLine 1 Modulator Aging High Alarm :Alarm indicating the Line 1 OTX TLH modulator aging is higher than the threshold written in the EEPROM <Condtype> CLIENT_MOD…
1.3.6.1.4.1.20044.48.2.2.2.22.6Scalarpm801rrAlmClientAgingHighAlaread-onlycurrentLine 1 OTX TLH Aging High Alarm :Alarm indicating the Line 1 OTX TLH aging is higher than the threshold written in the EEPROM <Condtype> CLIENT_AGING_HIGH_ALA …
1.3.6.1.4.1.20044.48.2.2.2.22.9Scalarpm801rrAlmClientCdrNotReadyread-onlycurrentLine 1 CDR Not Ready :This OID indicates the Clock Data Recovery unit is not yet initialized <Help> This alarm indicates the Clock Data Recovery unit is not ye…
1.3.6.1.4.1.20044.48.2.2.2.22.12Scalarpm801rrAlmClientFreqDevHighAlaread-onlycurrentLine 1 Freq. Deviation High Alarm :Alarm indicating the Line 1 OTX TLH frequency deviation is higher than the threshold written in the EEPROM <Condtype> CLIENT…
1.3.6.1.4.1.20044.48.2.2.2.22.14Scalarpm801rrAlmClientLaserTempHighAlaread-onlycurrentLine 1 Laser Temp. High Alarm :Alarm indicating the Line 1 OTX TLH laser temperature is higher than the threshold written in the EEPROM <Condtype> CLIENT_LASER…
1.3.6.1.4.1.20044.48.2.2.3Nodepm801rrAlmClientCrit
1.3.6.1.4.1.20044.48.2.2.3.8Nodepm801rrAlmsynthAlm8
1.3.6.1.4.1.20044.48.2.2.3.8.1Scalarpm801rrAlmClientXfpAbsentread-onlycurrentLine 1 Optical Module Absent :This OID indicates the Line 1 optical interface (XFP or OTX) is not present in the PM <Help> This alarm indicates if the line 1 t…
1.3.6.1.4.1.20044.48.2.2.3.8.2Scalarpm801rrAlmClientInitNotComplread-onlycurrentLine 1 Optical Module Ready :This OID indicates the optical interface (XFP or OTX) is not operational <Help> This status indicates if the line 1 transceiver ha…
1.3.6.1.4.1.20044.48.2.2.3.8.4Scalarpm801rrAlmClientHwFailread-onlycurrentLine 1 Port HW Failure :This OID indicates a failure on Line 1 port, most probably caused by a HW issue. <Condtype> CLIENT_HW_FAIL <Probcause> equipmentMalfunc…
1.3.6.1.4.1.20044.48.2.2.3.8.5Scalarpm801rrAlmClientXfpTxOffread-onlycurrentLine 1 Optical Module Laser Shutdown :This OID indicates the Line 1 optical output power is off <Help> This status indicates if the line 1 transceiver laser is…
1.3.6.1.4.1.20044.48.2.2.3.8.9Scalarpm801rrAlmClientDdmWarningread-onlycurrentWarning On Line 1 Optical Module DDM :This OID indicates a warning is present coming out of Line 1 optical interface DDM <Help> This alarm indicates if a DDM W…
1.3.6.1.4.1.20044.48.2.2.3.8.10Scalarpm801rrAlmClientDdmAlmread-onlycurrentAlarm On Line 1 Optical Module DDM :This OID indicates an alarm is present coming out of Line 1 optical interface DDM <Help> This alarm indicates if a DDM Alar…
1.3.6.1.4.1.20044.48.2.2.3.8.12Scalarpm801rrAlmClientFailread-onlycurrentLine 1 Port Failure :This OID indicates a failure on the Line 1 port <Condtype> CLIENT_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (1…
1.3.6.1.4.1.20044.48.2.2.3.8.14Scalarpm801rrAlmClientVccWarningread-onlycurrentLine 1VCC Warning :This OID indicates an overall VCC warning is set over the Line 1 XFP <Condtype> CLIENT_VCC_WARNING <Probcause> powerProblem (36) <Alarmtype>…
1.3.6.1.4.1.20044.48.2.2.3.8.15Scalarpm801rrAlmClientVccAlarmread-onlycurrentLine 1 VCC Alarm :This OID indicates an overall VCC alarm is set over the Line 1 XFP <Condtype> CLIENT_VCC_ALARM <Probcause> powerProblem (36) <Alarmtype> equi…
1.3.6.1.4.1.20044.48.2.2.3.19Nodepm801rrAlmclientXfpAlarms2
1.3.6.1.4.1.20044.48.2.2.3.19.1Scalarpm801rrAlmClientResetCompleteread-onlycurrentNot Used :This bit indicates that the internal reset process is completed and the data are available <Condtype> CLIENT_RESET_COMPLETE <Probcause> other (1) <Al…
1.3.6.1.4.1.20044.48.2.2.3.19.3Scalarpm801rrAlmClientRxCdrNotLockedread-onlycurrentLine 1 Optical Rx CDR Unlocked :This OID indicates that a loss of lock on the Line 1 receiving side CDR has been detected <Condtype> CLIENT_RX_CDR_NOT_LOCKED <…
1.3.6.1.4.1.20044.48.2.2.3.19.4Scalarpm801rrAlmClientRxLosread-onlycurrentLine 1 Loss Of Optical Signal :This bit indicates an absence of signal on the XFP/OTX <Help> This alarm indicates if an optical signal is detected on the line …
1.3.6.1.4.1.20044.48.2.2.3.19.5Scalarpm801rrAlmClientRxNrread-onlycurrentLine 1 Optical Rx Not Ready :This OID indicates that a condition has arisen leading to invalid data on the Line 1 receiving side. <Condtype> CLIENT_RX_NR <Prob…
1.3.6.1.4.1.20044.48.2.2.3.19.6Scalarpm801rrAlmClientTxCdrNotLockedread-onlycurrentLine 1 Optical Tx CDR Unlocked :This OID indicates a loss of lock on the Line 1 transmitting side CDR has been detected. <Condtype> CLIENT_TX_CDR_NOT_LOCKED <P…
1.3.6.1.4.1.20044.48.2.2.3.19.7Scalarpm801rrAlmClientTxFaultread-onlycurrentLine 1 Optical Tx Failure :This OID indicates a fault condition on the Line 1 laser detected by the safety syste <Condtype> CLIENT_TX_FAULT <Probcause> transmi…
1.3.6.1.4.1.20044.48.2.2.3.19.8Scalarpm801rrAlmClientTxNrread-onlycurrentLine 1 Optical Tx Not Ready :This OID indicates a condition has arisen leading to invalid data on the Line 1 transmitting side <Condtype> CLIENT_TX_NR <Probcau…
1.3.6.1.4.1.20044.48.2.2.3.19.10Scalarpm801rrAlmClientChannelNotAcquiredread-onlycurrentLine 1 DWDM Channel Not Acquired :This OID indicates the transceiver didn't tune the DWDM Channel succesfully. <Help> This status indicates the transceiver has…
1.3.6.1.4.1.20044.48.2.2.3.19.14Scalarpm801rrAlmClientWavelengthUnlockedread-onlycurrentLine 1 Optical Tx Wavelength Unlocked :This OID indicates that the Line 1 wavelength error is exceeding the manufacturer tolerance <Condtype> CLIENT_WAVELENGTH…
1.3.6.1.4.1.20044.48.2.2.3.19.15Scalarpm801rrAlmClientTecFaultread-onlycurrentLine 1 Optical Tx Temp Regul. Failed :This OID indicates a failure on the Line 1 TEC module <Condtype> CLIENT_TEC_FAULT <Probcause> transmitterFailure (56) <Al…
1.3.6.1.4.1.20044.48.2.2.3.19.16Scalarpm801rrAlmClientApdSupplyFaultread-onlycurrentLine 1 Rx Photodiode Power Failed :This OID indicates a failure on the Line 1 APD power supply <Condtype> CLIENT_APD_SUPPLY_FAULT <Probcause> receiverFailure (…
1.3.6.1.4.1.20044.48.2.3Nodepm801rrAlmLine
1.3.6.1.4.1.20044.48.2.3.1Nodepm801rrAlmLineNurg
1.3.6.1.4.1.20044.48.2.3.1.25Nodepm801rrAlmlineXfpWarnings
1.3.6.1.4.1.20044.48.2.3.1.25.1Scalarpm801rrAlmLineTxPwrLowWngread-onlycurrentLine 2 Optical Tx Power Low Warning :Warning indicating that the Line 2 XFP/OTX transmitter transmitter output power is lower than the threshold value written …
1.3.6.1.4.1.20044.48.2.3.1.25.2Scalarpm801rrAlmLineTxPwrHighWngread-onlycurrentLine 2 Optical Tx Power High Warning :Warning indicating that the Line 2 XFP/OTX transmitter transmitter output power is higher than the threshold value writte…
1.3.6.1.4.1.20044.48.2.3.1.25.3Scalarpm801rrAlmLineTxBiasLowWngread-onlycurrentLine 2 Transceiver Bias Low Warning :Warning indicating that the Line 2 XFP/OTX transmitter laser bias current is lower than the threshold value written in the…
1.3.6.1.4.1.20044.48.2.3.1.25.4Scalarpm801rrAlmLineTxBiasHighWngread-onlycurrentLine 2 Transceiver Bias High Warning :Warning indicating that the Line 2 XFP/OTX transmitter laser bias current is higher than the threshold value written in t…
1.3.6.1.4.1.20044.48.2.3.1.25.7Scalarpm801rrAlmLineTempLowWngread-onlycurrentLine 2 Transceiver Temp Low Warning :Warning indicating that the Line 2 XFP/OTX temperature is lower than the threshold value written in the Line 2 XFP/OTX EEP…
1.3.6.1.4.1.20044.48.2.3.1.25.8Scalarpm801rrAlmLineTempHighWngread-onlycurrentLine 2 Transceiver Temp High Warning :Warning indicating that the Line 2 XFP/OTX temperature is higher than the threshold value written in the Line 2 XFP/OTX E…
1.3.6.1.4.1.20044.48.2.3.1.25.15Scalarpm801rrAlmLineRxPwrLowWngread-onlycurrentLine 2 Optical Rx Power Low Warning :Warning indicating that the Line 2 XFP/OTX received optical power is lower than the threshold value written in the Line 2 …
1.3.6.1.4.1.20044.48.2.3.1.25.16Scalarpm801rrAlmLineRxPwrHighWngread-onlycurrentLine 2 Optical Rx Power High Warning :Warning indicating that the Line 2 XFP/OTX received optical power is higher than the threshold value written in the Line …
1.3.6.1.4.1.20044.48.2.3.1.31Nodepm801rrAlmrrLineOtxTlhWarnings
1.3.6.1.4.1.20044.48.2.3.1.31.5Scalarpm801rrAlmLineModulatorAgingHighWarningread-onlycurrentLine 2 Modulator Aging High Warning :Warning indicating the Line 2 OTX TLH modulator aging is higher than the threshold written in the EEPROM <Condtype> LINE_M…
1.3.6.1.4.1.20044.48.2.3.1.31.6Scalarpm801rrAlmLineAgingHighWarningread-onlycurrentLine 2 OTX TLH Aging High Warning :Warning indicating the Line 2 OTX TLH aging is higher than the threshold written in the EEPROM <Condtype> LINE_AGING_HIGH_WA…
1.3.6.1.4.1.20044.48.2.3.1.31.12Scalarpm801rrAlmLineFreqDevHighWarningread-onlycurrentLine 2 Freq. Deviation High Warning :Warning indicating the Line 2 OTX TLH frequency deviation is higher than the threshold written in the EEPROM <Condtype> LI…
1.3.6.1.4.1.20044.48.2.3.1.31.14Scalarpm801rrAlmLineLaserTempHighWarningread-onlycurrentLine 2 Laser Temp. High Warning :Warning indicating the Line 2 OTX TLH laser temperature is higher than the threshold written in the EEPROM <Condtype> LINE_LAS…
1.3.6.1.4.1.20044.48.2.3.2Nodepm801rrAlmLineUrg
1.3.6.1.4.1.20044.48.2.3.2.24Nodepm801rrAlmlineXfpAlarm1
1.3.6.1.4.1.20044.48.2.3.2.24.1Scalarpm801rrAlmLineTxPwrLowAlaread-onlycurrentLine 2 Optical Tx Power Low :Alarm indicating that the Line 2 XFP/OTX transmitter transmitter output power is lower than the threshold value written in the Lin…
1.3.6.1.4.1.20044.48.2.3.2.24.2Scalarpm801rrAlmLineTxPwrHighAlaread-onlycurrentLine 2 Optical Tx Power High :Alarm indicating that the Line 2 XFP/OTX transmitter transmitter output power is higher than the threshold value written in the L…
1.3.6.1.4.1.20044.48.2.3.2.24.3Scalarpm801rrAlmLineTxBiasLowAlaread-onlycurrentLine 2 Transceiver Bias Low :Alarm indicating that the Line 2 XFP/OTX transmitter laser bias current is lower than the threshold value written in the Line 2 XF…
1.3.6.1.4.1.20044.48.2.3.2.24.4Scalarpm801rrAlmLineTxBiasHighAlaread-onlycurrentLine 2 Transceiver Bias High :Alarm indicating that the Line 2 XFP/OTX transmitter laser bias current is higher than the threshold value written in the Line 2 …
1.3.6.1.4.1.20044.48.2.3.2.24.7Scalarpm801rrAlmLineTempLowAlaread-onlycurrentLine 2 Transceiver Temp Low :Alarm indicating that the Line 2 XFP/OTX temperature is lower than the threshold value written in the Line 2 XFP/OTX EEPROM <Condt…
1.3.6.1.4.1.20044.48.2.3.2.24.8Scalarpm801rrAlmLineTempHighAlaread-onlycurrentLine 2 Transceiver Temp High :Alarm indicating that the Line 2 XFP/OTX temperature is higher than the threshold value written in the Line 2 XFP/OTX EEPROM <Con…
1.3.6.1.4.1.20044.48.2.3.2.24.15Scalarpm801rrAlmLineRxPwrLowAlaread-onlycurrentLine 2 Optical Rx Power Low :Alarm indicating that the Line 2 XFP/OTX received optical power is lower than the threshold value written in the Line 2 XFP/OTX EE…
1.3.6.1.4.1.20044.48.2.3.2.24.16Scalarpm801rrAlmLineRxPwrHighAlaread-onlycurrentLine 2 Optical Rx Power High :Alarm indicating that the Line 2 XFP/OTX received optical power is higher than the threshold value written in the Line 2 XFP/OTX …
1.3.6.1.4.1.20044.48.2.3.2.30Nodepm801rrAlmrrLineOtxTlhAlarms3
1.3.6.1.4.1.20044.48.2.3.2.30.5Scalarpm801rrAlmLineModulatorAgingHighAlaread-onlycurrentLine 2 Modulator Aging High Alarm :Alarm indicating the Line 2 OTX TLH modulator aging is higher than the threshold written in the EEPROM <Condtype> LINE_MODUL…
1.3.6.1.4.1.20044.48.2.3.2.30.6Scalarpm801rrAlmLineAgingHighAlaread-onlycurrentLine 2 OTX TLH Aging High Alarm :Alarm indicating the Line 2 OTX TLH aging is higher than the threshold written in the EEPROM <Condtype> LINE_AGING_HIGH_ALA <P…
1.3.6.1.4.1.20044.48.2.3.2.30.9Scalarpm801rrAlmLineCdrNotReadyread-onlycurrentLine 2 CDR Not Ready :This OID indicates the Clock Data Recovery unit is not yet initialized <Help> This alarm indicates the Clock Data Recovery unit is not ye…
1.3.6.1.4.1.20044.48.2.3.2.30.12Scalarpm801rrAlmLineFreqDevHighAlaread-onlycurrentLine 2 Freq. Deviation High Alarm :Alarm indicating the Line 2 OTX TLH frequency deviation is higher than the threshold written in the EEPROM <Condtype> LINE_F…
1.3.6.1.4.1.20044.48.2.3.2.30.14Scalarpm801rrAlmLineLaserTempHighAlaread-onlycurrentLine 2 Laser Temp. High Alarm :Alarm indicating the Line 2 OTX TLH laser temperature is higher than the threshold written in the EEPROM <Condtype> LINE_LASER_T…
1.3.6.1.4.1.20044.48.2.3.3Nodepm801rrAlmLineCrit
1.3.6.1.4.1.20044.48.2.3.3.7Nodepm801rrAlmsynthAlm7
1.3.6.1.4.1.20044.48.2.3.3.7.1Scalarpm801rrAlmLineXfpAbsentread-onlycurrentLine 2 Optical Module Absent :This OID indicates the Line 2 optical interface (XFP or OTX) is not present in the PM <Help> This alarm indicates if the line 2 t…
1.3.6.1.4.1.20044.48.2.3.3.7.2Scalarpm801rrAlmLineInitNotComplread-onlycurrentLine 2 Optical Module Ready :This OID indicates the optical interface (XFP or OTX) is not operational <Help> This status indicates if the line 2 transceiver ha…
1.3.6.1.4.1.20044.48.2.3.3.7.4Scalarpm801rrAlmLineHwFailread-onlycurrentLine 2 Port HW Failure :This OID indicates a failure on Line 2 port, most probably caused by a HW issue <Condtype> LINE_HW_FAIL <Probcause> equipmentMalfunctio…
1.3.6.1.4.1.20044.48.2.3.3.7.5Scalarpm801rrAlmLineXfpTxOffread-onlycurrentLine 2 Optical Module Laser Shutdown :This OID indicates the Line 2 optical output power is off <Help> This status indicates if the line 2 transceiver laser is…
1.3.6.1.4.1.20044.48.2.3.3.7.9Scalarpm801rrAlmLineDdmWarningread-onlycurrentWarning On Line 2 Optical Module DDM :This OID indicates a warning is present coming out of Line 2 optical interface DDM <Help> This alarm indicates if a DDM W…
1.3.6.1.4.1.20044.48.2.3.3.7.10Scalarpm801rrAlmLineDdmAlmread-onlycurrentAlarm On Line 2 Optical Module DDM :This OID indicates an alarm is present coming out of Line 2 optical interface DDM <Help> This alarm indicates if a DDM Alar…
1.3.6.1.4.1.20044.48.2.3.3.7.12Scalarpm801rrAlmLineFailread-onlycurrentLine 2 Port Failure :This OID indicates a failure on the Line 2 port <Condtype> LINE_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12)…
1.3.6.1.4.1.20044.48.2.3.3.7.14Scalarpm801rrAlmLineVccWarningread-onlycurrentLine 2 VCC Warning :This OID indicates an overall VCC warning is set over the Line 2 XFP <Condtype> LINE_VCC_WARNING <Probcause> powerProblem (36) <Alarmtype> …
1.3.6.1.4.1.20044.48.2.3.3.7.15Scalarpm801rrAlmLineVccAlarmread-onlycurrentLine 2 VCC Alarm :This OID indicates an overall VCC alarm is set over the Line 2 XFP <Condtype> LINE_VCC_ALARM <Probcause> powerProblem (36) <Alarmtype> equipm…
1.3.6.1.4.1.20044.48.2.3.3.27Nodepm801rrAlmlineXfpAlarms2
1.3.6.1.4.1.20044.48.2.3.3.27.1Scalarpm801rrAlmLineResetCompleteread-onlycurrentNot Used :This bit indicates that the internal reset process is completed and the data are available <Condtype> LINE_RESET_COMPLETE <Probcause> other (1) <Alar…
1.3.6.1.4.1.20044.48.2.3.3.27.3Scalarpm801rrAlmLineRxCdrNotLockedread-onlycurrentLine 2 Optical Rx CDR Unlocked :This OID indicates that a loss of lock on the Line 2 receiving side CDR has been detected <Condtype> LINE_RX_CDR_NOT_LOCKED <Pr…
1.3.6.1.4.1.20044.48.2.3.3.27.4Scalarpm801rrAlmLineRxLosread-onlycurrentLine 2 Loss Of Optical Signal :This bit indicates an absence of signal on the XFP/OTX <Help> This alarm indicates if an optical signal is detected on the line …
1.3.6.1.4.1.20044.48.2.3.3.27.5Scalarpm801rrAlmLineRxNrread-onlycurrentLine 2 Optical Rx Not Ready :This OID indicates that a condition has arisen leading to invalid data on the Line 2 receiving side. <Condtype> LINE_RX_NR <Probca…
1.3.6.1.4.1.20044.48.2.3.3.27.6Scalarpm801rrAlmLineTxCdrNotLockedread-onlycurrentLine 2 Optical Tx CDR Unlocked :This OID indicates a loss of lock on the Line 2 transmitting side CDR has been detected. <Condtype> LINE_TX_CDR_NOT_LOCKED <Pro…
1.3.6.1.4.1.20044.48.2.3.3.27.7Scalarpm801rrAlmLineTxFaultread-onlycurrentLine 2 Optical Tx Failure :This OID indicates a fault condition on the Line 2 laser detected by the safety syste <Condtype> LINE_TX_FAULT <Probcause> transmitt…
1.3.6.1.4.1.20044.48.2.3.3.27.8Scalarpm801rrAlmLineTxNrread-onlycurrentLine 2 Optical Tx Not Ready :This OID indicates a condition has arisen leading to invalid data on the Line 2 transmitting side <Condtype> LINE_TX_NR <Probcause…
1.3.6.1.4.1.20044.48.2.3.3.27.10Scalarpm801rrAlmLineChannelNotAcquiredread-onlycurrentLine 2 DWDM Channel Not Acquired :This OID indicates the transceiver didn't tune the DWDM Channel succesfully. <Help> This status indicates the transceiver has…
1.3.6.1.4.1.20044.48.2.3.3.27.14Scalarpm801rrAlmLineWavelengthUnlockedread-onlycurrentLine 2 Optical Tx Wavelength Unlocked :This OID indicates that the Line 2 wavelength error is exceeding the manufacturer tolerance <Condtype> LINE_WAVELENGTH_U…
1.3.6.1.4.1.20044.48.2.3.3.27.15Scalarpm801rrAlmLineTecFaultread-onlycurrentLine 2 Optical Tx Temp Regul. Failed :This OID indicates a failure on the Line 2 TEC module <Condtype> LINE_TEC_FAULT <Probcause> transmitterFailure (56) <Alar…
1.3.6.1.4.1.20044.48.2.3.3.27.16Scalarpm801rrAlmLineApdSupplyFaultread-onlycurrentLine 2 Rx Photodiode Power Failed :This OID indicates a failure on the Line 2 APD power supply <Condtype> LINE_APD_SUPPLY_FAULT <Probcause> receiverFailure (42…
1.3.6.1.4.1.20044.48.3Nodepm801rrmeasures
1.3.6.1.4.1.20044.48.3.1Nodepm801rrMesrOther
1.3.6.1.4.1.20044.48.3.2Nodepm801rrMesrClient
1.3.6.1.4.1.20044.48.3.2.16Scalarpm801rrMesrclientTemperatureread-onlycurrentLine 1 Optical Module Temperature :This OID gives the temperature of the Client XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/25…
1.3.6.1.4.1.20044.48.3.2.18Scalarpm801rrMesrclientTxBiasread-onlycurrentLine 1 XFP/OTX Tx Bias Current :This OID gives the bias value of the Client XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = …
1.3.6.1.4.1.20044.48.3.2.19Scalarpm801rrMesrclientTxPowerread-onlycurrentLine 1 Optical Module Tx Power :This OID gives the transmit power value of the Client XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*lo…
1.3.6.1.4.1.20044.48.3.2.20Scalarpm801rrMesrclientRxPowerread-onlycurrentLine 1 Optical Module Rx Power :This OID gives the receive power value of the Client XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log…
1.3.6.1.4.1.20044.48.3.2.32Scalarpm801rrMesrclientAgingread-onlycurrentLine 1 OTX TLH Aging :This OID gives the aging of the Line 1 OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Aging = AV) (Unit = %) <Help> This mea…
1.3.6.1.4.1.20044.48.3.2.33Scalarpm801rrMesrclientLaserTemperatureread-onlycurrentLine 1 OTX TLH Laser Temperature :This OID gives the laser temperature of the Line 1 OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Temperature = …
1.3.6.1.4.1.20044.48.3.2.34Scalarpm801rrMesrclientFreqDeviationread-onlycurrentLine 1 OTX TLH Frequency Deviation :This OID gives the frequency deviation of the Line 1 OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Deviation …
1.3.6.1.4.1.20044.48.3.2.35Scalarpm801rrMesrclientLaserWvlengthread-onlycurrentLine 1 Optical Module Wavelength :This OID gives the laser wavelength of the Line 1 OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Wavelength=2997…
1.3.6.1.4.1.20044.48.3.3Nodepm801rrMesrLine
1.3.6.1.4.1.20044.48.3.3.24Scalarpm801rrMesrlineTemperatureread-onlycurrentLine 2 Optical Module Temperature :This OID gives the temperature of the Line XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256)…
1.3.6.1.4.1.20044.48.3.3.26Scalarpm801rrMesrlineTxBiasread-onlycurrentLine 2 XFP/OTX Tx Bias Current :This OID gives the bias value of the Line XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA…
1.3.6.1.4.1.20044.48.3.3.27Scalarpm801rrMesrlineTxPowerread-onlycurrentLine 2 Optical Module Tx Power :This OID gives the transmit power value of the Line XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(…
1.3.6.1.4.1.20044.48.3.3.28Scalarpm801rrMesrlineRxPowerread-onlycurrentLine 2 Optical Module Rx Power :This OID gives the receive power value of the Line XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(A…
1.3.6.1.4.1.20044.48.3.3.40Scalarpm801rrMesrlineAgingread-onlycurrentLine 2 OTX TLH Aging :This OID gives the aging of the Line 2 OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Aging = AV) (Unit = %) <Help> This mea…
1.3.6.1.4.1.20044.48.3.3.41Scalarpm801rrMesrlineLaserTemperatureread-onlycurrentLine 2 OTX TLH Laser Temperature :This OID gives the laser temperature of the Line 2 OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Temperature = …
1.3.6.1.4.1.20044.48.3.3.42Scalarpm801rrMesrlineFreqDeviationread-onlycurrentLine 2 OTX TLH Frequency Deviation :This OID gives the frequency deviation of the Line 2 OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Deviation …
1.3.6.1.4.1.20044.48.3.3.43Scalarpm801rrMesrlineLaserWvlengthread-onlycurrentLine 2 Optical Module Wavelength :This OID gives the laser wavelength of the Line 2 OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Wavelength=2997…
1.3.6.1.4.1.20044.48.6Nodepm801rrcontrolsWrite
1.3.6.1.4.1.20044.48.6.1Nodepm801rrCtrlOther
1.3.6.1.4.1.20044.48.6.1.0Nodepm801rrCtrlsynth0
1.3.6.1.4.1.20044.48.6.1.0.1Scalarpm801rrCtrlConfLoadread-writecurrentLoad Configuration Tables :When set this enables loading from flash configuration1 into the module.
1.3.6.1.4.1.20044.48.6.1.0.9Scalarpm801rrCtrlConfFlashread-writecurrentWrite Configuration Tables :This bit saves the current configuration of the module as configuration in the flash. <Help> This control saves the customer config…
1.3.6.1.4.1.20044.48.6.1.0.13Scalarpm801rrCtrlConfClearread-writecurrentClear Configuration Tables :This bit clears the configuration tables from configuration in the flash. <Help> This control restores the default configuration of…
1.3.6.1.4.1.20044.48.6.1.4Nodepm801rrCtrlsynth4
1.3.6.1.4.1.20044.48.6.1.4.1Scalarpm801rrCtrlCorrelatOnread-writecurrentEnable Alarm Correlation :This OID enables the alarm correlation in the PM
1.3.6.1.4.1.20044.48.6.1.4.2Scalarpm801rrCtrlCorrelatOffread-writecurrentDisable Alarm Correlation :This OID disables the alarm correlation in the PM
1.3.6.1.4.1.20044.48.6.1.5Nodepm801rrCtrlswMgnt
1.3.6.1.4.1.20044.48.6.1.5.2Scalarpm801rrCtrlColdResetread-writecurrentSoftware Cold Reset :This OID, when set, causes a cold reset of the Software. This reset is traffic affecting, and the configuration of Software is reloaded on…
1.3.6.1.4.1.20044.48.6.1.5.3Scalarpm801rrCtrlWarmResetread-writecurrentSoftware Warm Reset :This OID, when set, causes a warm reset of the Software. This reset is not traffic affecting, and the configuration of the Sofwtare remain…
1.3.6.1.4.1.20044.48.6.1.64Nodepm801rrCtrlledTest
1.3.6.1.4.1.20044.48.6.1.64.1Scalarpm801rrCtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.48.6.1.64.2Scalarpm801rrCtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.48.6.1.64.3Scalarpm801rrCtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.48.6.2Nodepm801rrCtrlClient
1.3.6.1.4.1.20044.48.6.2.16Nodepm801rrCtrlclientXfpOnoff
1.3.6.1.4.1.20044.48.6.2.16.1Scalarpm801rrCtrlClientXfpOnoffread-writecurrentXFP/OTX Laser Shut Down :This OID switches off the Line 1 XFP/OTX <Help> This control defines the laser state of the line 1 transceiver
1.3.6.1.4.1.20044.48.6.2.17Nodepm801rrCtrlclientXfpLineLoop
1.3.6.1.4.1.20044.48.6.2.17.1Scalarpm801rrCtrlClientXfpLineLoopread-writecurrentXFP/OTX Loop :This OID operates a loopback on the Line 1 XFP/OTX <Help> This control defines the line loop back of the line 1 transceiver
1.3.6.1.4.1.20044.48.6.2.18Nodepm801rrCtrlclientXfiLoop
1.3.6.1.4.1.20044.48.6.2.18.1Scalarpm801rrCtrlClientXfiLoopread-writecurrentXFP/OTX XFI Loop :This OID operates a XFI loopback on the Line 1 XFP/OTX <Help> This control defines the XFI loop back of the line transceiver
1.3.6.1.4.1.20044.48.6.2.19Scalarpm801rrCtrlclientTunableChannelread-writecurrentITU Channel :This OID selects the ITU channel of the Line 1 OTX TLH Laser <Help> This control defines the ITU channel of the Line 1 OTX TLH Laser
1.3.6.1.4.1.20044.48.6.2.20Scalarpm801rrCtrlclientPhotodiodeModeread-writecurrentOTX TLH Rx Sens. Mode :This OID defines the Rx sensiblity mode of the Line 1 OTX TLH <Help> This control defines the receiver sensibility mode of the Line 1 OT…
1.3.6.1.4.1.20044.48.6.2.21Scalarpm801rrCtrlclientPhotodiodeValueread-writecurrentOTX TLH Rx Sensibility :This OID sets the Rx sensibility of the Line 1 OTX TLH (custom mode only) <Help> This control defines the receiver sensibility value (o…
1.3.6.1.4.1.20044.48.6.2.22Scalarpm801rrCtrlclientPowerLaserread-writecurrentLaser Output Power [3-5] :This OID sets the output power value on the laser of the Line 1 OTX TLH (AV=Power*10+158) (Unit = dBm) <Help> This control defines th…
1.3.6.1.4.1.20044.48.6.3Nodepm801rrCtrlLine
1.3.6.1.4.1.20044.48.6.3.23Nodepm801rrCtrlclientOtxVlhReset
1.3.6.1.4.1.20044.48.6.3.23.1Scalarpm801rrCtrlClientOtxVlhResetread-writecurrentOTX-VLH Reset :This OID resets the OTX-VLH module <Help> This control resets the OTX-TLH and its parameters
1.3.6.1.4.1.20044.48.6.3.24Nodepm801rrCtrllineXfpOnoff
1.3.6.1.4.1.20044.48.6.3.24.1Scalarpm801rrCtrlLineXfpOnoffread-writecurrentXFP/OTX Laser Shut Down :This OID switches off the Line 2 XFP/OTX <Help> This control defines the laser state of the line 2 transceiver
1.3.6.1.4.1.20044.48.6.3.25Nodepm801rrCtrllineXfpLineLoop
1.3.6.1.4.1.20044.48.6.3.25.1Scalarpm801rrCtrlLineXfpLineLoopread-writecurrentXFP/OTX Loop :This OID operates a loopback on the Line 2 XFP/OTX <Help> This control defines the line loop back of the line 2 transceiver
1.3.6.1.4.1.20044.48.6.3.26Nodepm801rrCtrllineXfiLoop
1.3.6.1.4.1.20044.48.6.3.26.1Scalarpm801rrCtrlLineXfiLoopread-writecurrentXFP/OTX XFI Loop :This OID operates a XFI loopback on the Line 2 XFP/OTX <Help> This control defines the XFI loop back of the line 2 transceiver
1.3.6.1.4.1.20044.48.6.3.27Scalarpm801rrCtrllineTunableChannelread-writecurrentITU Channel :This OID selects the ITU channel of the Line 2 OTX TLH Laser <Help> This control defines the ITU channel of the Line 2 OTX TLH Laser
1.3.6.1.4.1.20044.48.6.3.28Scalarpm801rrCtrllinePhotodiodeModeread-writecurrentOTX TLH Rx Sens. Mode :This OID defines the Rx sensiblity mode of the Line 2 OTX TLH <Help> This control defines the receiver sensibility mode of the Line 2 OT…
1.3.6.1.4.1.20044.48.6.3.29Scalarpm801rrCtrllinePhotodiodeValueread-writecurrentOTX TLH Rx Sensibility :This OID sets the Rx sensibility of the Line 2 OTX TLH (custom mode only) <Help> This control defines the receiver sensibility value (o…
1.3.6.1.4.1.20044.48.6.3.30Scalarpm801rrCtrllinePowerLaserread-writecurrentLaser Output Power [3-5] :This OID sets the output power value on the laser of the Line 2 OTX TLH (AV=Power*10+158) (Unit = dBm) <Help> This control defines th…
1.3.6.1.4.1.20044.48.6.3.31Nodepm801rrCtrllineOtxVlhReset
1.3.6.1.4.1.20044.48.6.3.31.1Scalarpm801rrCtrlLineOtxVlhResetread-writecurrentOTX-VLH Reset :This OID resets the OTX-VLH module <Help> This control resets the OTX-TLH and its parameters
1.3.6.1.4.1.20044.48.7Nodepm801rrri
1.3.6.1.4.1.20044.48.7.2Scalarpm801rrRinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.48.7.4Scalarpm801rrRinvHwPlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.48.7.5Scalarpm801rrRinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.48.7.6Scalarpm801rrRinvClientXFPread-onlycurrentInventory for the XFP: This OID contains the inventory for the Client XFP
1.3.6.1.4.1.20044.48.7.7Scalarpm801rrRinvLineXFPread-onlycurrentInventory for the XFP: This OID contains the inventory for the Line XFP
1.3.6.1.4.1.20044.48.9Nodepm801rrConfig
1.3.6.1.4.1.20044.48.9.1Nodepm801rrCfgLsd
1.3.6.1.4.1.20044.48.9.1.1Nodepm801rrtableclientLsd
1.3.6.1.4.1.20044.48.9.1.1.2Scalarpm801rrCfglsdModeread-writecurrentLSD mode on Client/Line Port :This OID enables/disables the automatic laser shutdown on the Client and Line ports
1.3.6.1.4.1.20044.48.9.1.1.3Scalarpm801rrCfgclientXfpAlarmsread-writecurrentLSD contributors on Client port :This OID configures the contributors for the automatic laser shutdown of the client port
1.3.6.1.4.1.20044.48.9.1.1.4Scalarpm801rrCfgclientXfpAbsenceread-writecurrentLSD contributors on Client port :This OID configures the contributors for the automatic laser shutdown of the client port
1.3.6.1.4.1.20044.48.9.1.1.5Scalarpm801rrCfglineXfpAlarmsread-writecurrentLSD contributors on Line port :This OID configures the contributors for the automatic laser shutdown of the line port
1.3.6.1.4.1.20044.48.9.1.1.6Scalarpm801rrCfglineXfpAbsenceread-writecurrentLSD contributors on Line port :This OID configures the contributors for the automatic laser shutdown of the line port
1.3.6.1.4.1.20044.48.9.2Nodepm801rrCfgStartUp
1.3.6.1.4.1.20044.48.9.2.1Nodepm801rrtableclientStartup
1.3.6.1.4.1.20044.48.9.2.1.2Scalarpm801rrCfgclientXfpCtrlread-writecurrentDefault Settings on Line 1 Port :This register configures the default initialisation settings on the client port.
1.3.6.1.4.1.20044.48.9.2.2Nodepm801rrtablelineStartup
1.3.6.1.4.1.20044.48.9.2.2.2Scalarpm801rrCfglineXfpCtrlread-writecurrentDefault Settings on Line 2 Port :This register configures the default initialisation settings on the line port.
1.3.6.1.4.1.20044.48.9.2.2.18Scalarpm801rrCfgprotocolSelectread-writecurrentBitrate selection on Line/Client port :This OID register configure the bitrate for the client and line interface (0=9,953 Gb/s - 1=10,3125 Gb/s - 2=9,953 Gb/s …
1.3.6.1.4.1.20044.48.9.2.3Nodepm801rrtableclientOtxtlh
1.3.6.1.4.1.20044.48.9.2.3.2Scalarpm801rrCfgclientDitherControlread-writecurrentDefault Settings on Dither Line 1 :This register configures the default initialisation settings on the dither of the client port.
1.3.6.1.4.1.20044.48.9.2.3.3Scalarpm801rrCfgclientDitherRateread-writecurrentDefault Line 1 OTX TLH FM amplitude :This register configures the start-up width of the frequency modulation of the line 1 OTX TLH
1.3.6.1.4.1.20044.48.9.2.3.4Scalarpm801rrCfgclientDitherFhzread-writecurrentDefault Line 1 OTX TLH FM frequency :This register configures the start-up frequency of the frequency modulation of the line 1 OTX TLH
1.3.6.1.4.1.20044.48.9.2.3.5Scalarpm801rrCfgclientPwrLaserread-writecurrentDefaut Line 1 OTX TLH output Power :This register configures the start-up output power of the line 1 OTX TLH (Unit = dBm)
1.3.6.1.4.1.20044.48.9.2.3.6Scalarpm801rrCfgclientFCurrentread-writecurrentDefault Line 1 OTX TLH Channel :This register configures the start-up laser channel of the line 1 OTX TLH
1.3.6.1.4.1.20044.48.9.2.3.7Scalarpm801rrCfgclientGridCurrentread-writecurrentDefault Line 1 OTX TLH Grid :This register configures the start-up laser grid of the line 1 OTX TLH
1.3.6.1.4.1.20044.48.9.2.3.8Scalarpm801rrCfgclientF0read-writecurrentDefault Line 1 OTX TLH lowest Freq :This register configures the start-up lowest frequency supported on the line 1 OTX TLH
1.3.6.1.4.1.20044.48.9.2.3.10Scalarpm801rrCfgclientPhotodiodeModeread-writecurrentDefault Line 1 OTX TLH APD mode :This register configures the start-up APD mode of the line 1 OTX TLH
1.3.6.1.4.1.20044.48.9.2.3.11Scalarpm801rrCfgclientPhotodiodeValueread-writecurrentDefault Line 1 OTX TLH APD atten. :This register configures the start-up APD attenuation on the line 1 OTX TLH
1.3.6.1.4.1.20044.48.9.2.4Nodepm801rrtablelineOtxtlh
1.3.6.1.4.1.20044.48.9.2.4.2Scalarpm801rrCfglineDitherControlread-writecurrentDefault Settings on Dither Line 2 :This register configures the default initialisation settings on the dither of the client port.
1.3.6.1.4.1.20044.48.9.2.4.3Scalarpm801rrCfglineDitherRateread-writecurrentDefault Line 2 OTX TLH FM amplitude :This register configures the start-up width of the frequency modulation of the line 2 OTX TLH
1.3.6.1.4.1.20044.48.9.2.4.4Scalarpm801rrCfglineDitherFhzread-writecurrentDefault Line 2 OTX TLH FM frequency :This register configures the start-up frequency of the frequency modulation of the line 2 OTX TLH
1.3.6.1.4.1.20044.48.9.2.4.5Scalarpm801rrCfglinePwrLaserread-writecurrentDefaut Line 2 OTX TLH output Power :This register configures the start-up output power of the line 2 OTX TLH (Unit = dBm)
1.3.6.1.4.1.20044.48.9.2.4.6Scalarpm801rrCfglineFCurrentread-writecurrentDefault Line 2 OTX TLH Channel :This register configures the start-up laser channel of the line 2 OTX TLH
1.3.6.1.4.1.20044.48.9.2.4.7Scalarpm801rrCfglineGridCurrentread-writecurrentDefault Line 2 OTX TLH Grid :This register configures the start-up laser grid of the line 2 OTX TLH
1.3.6.1.4.1.20044.48.9.2.4.8Scalarpm801rrCfglineF0read-writecurrentDefault Line 2 OTX TLH lowest Freq :This register configures the start-up lowest frequency supported on the line 2 OTX TLH
1.3.6.1.4.1.20044.48.9.2.4.10Scalarpm801rrCfglinePhotodiodeModeread-writecurrentDefault Line 2 OTX TLH APD mode :This register configures the start-up APD mode of the line 2 OTX TLH
1.3.6.1.4.1.20044.48.9.2.4.11Scalarpm801rrCfglinePhotodiodeValueread-writecurrentDefault Line 2 OTX TLH APD atten. :This register configures the start-up APD attenuation on the line 2 OTX TLH
1.3.6.1.4.1.20044.48.9.3Nodepm801rrCfgLabels
1.3.6.1.4.1.20044.48.9.3.1Tablepm801rrCfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.48.9.3.1.1Rowpm801rrCfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.48.9.3.1.1.1Columnpm801rrCfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.48.9.3.1.1.3Columnpm801rrCfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.48.9.3.2Tablepm801rrCfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.48.9.3.2.1Rowpm801rrCfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.48.9.3.2.1.1Columnpm801rrCfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.48.9.3.2.1.3Columnpm801rrCfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.48.9.4Nodepm801rrCfgStartuptablefive
1.3.6.1.4.1.20044.48.9.4.1Tablepm801rrCfgOtxtlhcapabilitiesTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.48.9.4.1.1Rowpm801rrCfgOtxtlhcapabilitiesEntrynot-accessiblecurrentRow definition for the startuptablefive table
1.3.6.1.4.1.20044.48.9.4.1.1.1Columnpm801rrCfgOtxtlhcapabilitiesIndexread-onlycurrentIndex definition for the otxtlhcapabilities table
1.3.6.1.4.1.20044.48.9.4.1.1.3Columnpm801rrCfgComponentTypePortnread-onlycurrentComponent parameters :This OID defines the component parameters
1.3.6.1.4.1.20044.48.9.4.1.1.4Columnpm801rrCfgMiscellaneousPortnread-onlycurrentMiscellaneous default settings :This OID defines the miscellaneous parameters
1.3.6.1.4.1.20044.48.9.4.1.1.5Columnpm801rrCfgFirstChannelPortnread-onlycurrentNumber of the first channel of the component :This OID defines the first channel number of the PM
1.3.6.1.4.1.20044.48.9.4.1.1.6Columnpm801rrCfgLastChannelPortnread-onlycurrentNumber of the last channel of the component :This OID defines the last channel number of the PM
1.3.6.1.4.1.20044.48.9.4.1.1.7Columnpm801rrCfgGridPortnread-onlycurrentGrid value of the component :This OID defines the grid of the PM
1.3.6.1.4.1.20044.48.9.257Scalarpm801rrCfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.48.10Nodepm801rrtraps
1.3.6.1.4.1.20044.48.10.4Scalarpm801rrtrapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.48.10.30Notificationpm801rrLineTrapNotUrgentGoesOncurrentNot urgent Line default is activated
1.3.6.1.4.1.20044.48.10.31Notificationpm801rrLineTrapNotUrgentGoesOffcurrentNot urgent Line default disappeared
1.3.6.1.4.1.20044.48.10.32Notificationpm801rrLineTrapUrgentGoesOncurrentUrgent Line default is activated
1.3.6.1.4.1.20044.48.10.33Notificationpm801rrLineTrapUrgentGoesOffcurrentUrgent Line default disappeared
1.3.6.1.4.1.20044.48.10.34Notificationpm801rrLineTrapCritGoesOncurrentCritical Line default is activated
1.3.6.1.4.1.20044.48.10.35Notificationpm801rrLineTrapCritGoesOffcurrentCritical Line default disappeared
1.3.6.1.4.1.20044.48.10.40Notificationpm801rrClientTrapNotUrgentGoesOncurrentNot urgent client default is activated
1.3.6.1.4.1.20044.48.10.41Notificationpm801rrClientTrapNotUrgentGoesOffcurrentNot urgent client default disappeared
1.3.6.1.4.1.20044.48.10.42Notificationpm801rrClientTrapUrgentGoesOncurrentUrgent client default is activated
1.3.6.1.4.1.20044.48.10.43Notificationpm801rrClientTrapUrgentGoesOffcurrentUrgent client default disappeared
1.3.6.1.4.1.20044.48.10.44Notificationpm801rrClientTrapCritGoesOncurrentCritical client default is activated
1.3.6.1.4.1.20044.48.10.45Notificationpm801rrClientTrapCritGoesOffcurrentCritical client default disappeared
1.3.6.1.4.1.20044.48.10.50Notificationpm801rrPowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.48.10.51Notificationpm801rrPowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared
Type Definitions
NameSyntaxStatusDescription
Pm801rrAdjustValueINTEGER { otxadjustvalue0(0), otxadjustvalue1(1), otxadjustvalue2(2), otxadjustvalue3(3), otxadjustvalue4(4), otxadjustvalue5(5), otxadjustvalue6(6), otxadjustvalue7(7), otxadjustvalue8(8), otxadjustvalue9(9), otxadjustvalue10(10) }currentDifferent values in Adjust mode on OTX-TLH on client and line ports
Pm801rrBitRateINTEGER { rateOC192(0), rate10GBELAN(1), rate10GBEWAN(2), rate10GFC(3), rate10FECG975(4), rate10FECG709(5) }currentdifferent rates for a client and line ports
Pm801rrOtxChannelINTEGERcurrentChannel selection on OTX-TLH on client and line ports
Pm801rrOtxGridINTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50) }currentDifferent grids on OTX-TLH on client and line ports
Pm801rrOtxModeINTEGER { otx80mode(1), otx60mode(2), otxadjustmode(4) }currentDifferent modes on OTX-TLH on client and line ports