EKINOPS-PmMC-MIB
176 objects
MIB for the Ekinops Pmmc hardware.
Imported Objects
| EKINOPS-MIB | EkiApiState EkiMeasureType EkiMode ekinops EkiOnOff EkiProtocol EkiState EkiSynchroMode |
| SNMPv2-SMI | Counter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20044.21 | IdentitymodulePmMC | MIB for the Ekinops Pmmc hardware. | ||
| 1.3.6.1.4.1.20044.21.2 | Nodepmmcalarms | |||
| 1.3.6.1.4.1.20044.21.2.1 | NodepmmcAlmOther | |||
| 1.3.6.1.4.1.20044.21.2.1.1 | NodepmmcAlmOtherNurg | |||
| 1.3.6.1.4.1.20044.21.2.1.2 | NodepmmcAlmOtherUrg | |||
| 1.3.6.1.4.1.20044.21.2.1.3 | NodepmmcAlmOtherCrit | |||
| 1.3.6.1.4.1.20044.21.2.1.3.0 | NodepmmcAlmsynthAlm0 | |||
| 1.3.6.1.4.1.20044.21.2.1.3.0.9 | ScalarpmmcAlmModuleGlobFailure | read-only | current | Module Failure :This OID is set on detection of a failure originating from the PM <Condtype> MODULE_GLOB_FAILURE <Probcause> equipmentMalfunction (16) <Alarmty… |
| 1.3.6.1.4.1.20044.21.2.1.3.0.14 | ScalarpmmcAlmSynUnlock | read-only | current | Synthesizer Not Locked :This OID indicates that the frequency synthesizer is not locked. <Help> This status indicates if the clock synthesizer is locked. <Cond… |
| 1.3.6.1.4.1.20044.21.2.1.3.0.15 | ScalarpmmcAlmDefFuseA | read-only | current | Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.21.2.1.3.0.16 | ScalarpmmcAlmDefFuseB | read-only | current | Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.21.2.2 | NodepmmcAlmClient | |||
| 1.3.6.1.4.1.20044.21.2.2.1 | NodepmmcAlmClientNurg | |||
| 1.3.6.1.4.1.20044.21.2.2.1.20 | NodepmmcAlmline1TrscvWarnDdm | |||
| 1.3.6.1.4.1.20044.21.2.2.1.20.1 | ScalarpmmcAlmLine1TxPwLowWng | read-only | current | TRSCV 1 Tx Power Low Warning :Warning indicating that the transceiver output power of Line 1 is lower than the threshold value written in the transceiver EEPRO… |
| 1.3.6.1.4.1.20044.21.2.2.1.20.2 | ScalarpmmcAlmLine1TxPwrHighWng | read-only | current | TRSCV 1 Tx Power High Warning :Warning indicating that the transceiver output power of Line 1 is higher than the threshold value written in the transceiver EEP… |
| 1.3.6.1.4.1.20044.21.2.2.1.20.3 | ScalarpmmcAlmLine1TxBiasLowWng | read-only | current | TRSCV 1 Bias Low Warning :Warning indicating that the transceiver laser bias current of Line 1 is lower than the threshold value written in the transceiver EEP… |
| 1.3.6.1.4.1.20044.21.2.2.1.20.4 | ScalarpmmcAlmLine1TxBiasHighWng | read-only | current | TRSCV 1 Bias High Warning :Warning indicating that the transceiver laser bias current of Line 1 is higher than the threshold value written in the transceiver E… |
| 1.3.6.1.4.1.20044.21.2.2.1.20.5 | ScalarpmmcAlmLine1VccLowWng | read-only | current | TRSCV 1 Power Supply Low Warning :Warning indicating that the transceiver power supply of Line 1 is lower than the threshold value written in the transceiver E… |
| 1.3.6.1.4.1.20044.21.2.2.1.20.6 | ScalarpmmcAlmLine1VccHighWng | read-only | current | TRSCV 1 Power Supply High Warning :Warning indicating that the transceiver power supply of Line 1 is higher than the threshold value written in the transceiver… |
| 1.3.6.1.4.1.20044.21.2.2.1.20.7 | ScalarpmmcAlmLine1TempLowWng | read-only | current | TRSCV 1 Temp Low Warning :Warning indicating that the transceiver temperature of Line 1 is lower than the threshold value written in the transceiver EEPROM <Co… |
| 1.3.6.1.4.1.20044.21.2.2.1.20.8 | ScalarpmmcAlmLine1TempHighWng | read-only | current | TRSCV 1 Temp High Warning :Warning indicating that the transceiver temperature of Line 1 is higher than the threshold value written in the transceiver EEPROM <… |
| 1.3.6.1.4.1.20044.21.2.2.1.20.15 | ScalarpmmcAlmLine1RxPwrLowWng | read-only | current | TRSCV 1 Rx Power Low Warning :Warning indicating that the transceiver input power of Line 1 is lower than the threshold value written in the transceiver EEPROM… |
| 1.3.6.1.4.1.20044.21.2.2.1.20.16 | ScalarpmmcAlmLine1RxPwrHighWng | read-only | current | TRSCV 1 Rx Power High Warning :Warning indicating that the transceiver input power of Line 1 is higher than the threshold value written in the transceiver EEPR… |
| 1.3.6.1.4.1.20044.21.2.2.1.23 | NodepmmcAlmline1CdrAlm | |||
| 1.3.6.1.4.1.20044.21.2.2.1.23.1 | ScalarpmmcAlmLine1CdrLossofsignal | read-only | current | Line 1 CDR Loss Of Signal :This OID indicates that a Loss of electrical signal is detected on the Line 1 CDR <Help> This alarm indicates if an electrical signa… |
| 1.3.6.1.4.1.20044.21.2.2.1.23.2 | ScalarpmmcAlmLine1CdrLossoflock | read-only | current | Line 1 CDR Loss Of Lock :This OID indicates that the Line 1 CDR is not locked <Help> This alarm indicates if Line 1 CDR is correclty locked on the input signal… |
| 1.3.6.1.4.1.20044.21.2.2.1.23.3 | ScalarpmmcAlmLine1CdrRefAbsent | read-only | current | Line 1 CDR Reference Clock Absent :This OID indicates that the CDR reference clock is absent on Line 1 <Help> This alarm indicates if the reference clock is pr… |
| 1.3.6.1.4.1.20044.21.2.2.2 | NodepmmcAlmClientUrg | |||
| 1.3.6.1.4.1.20044.21.2.2.2.18 | NodepmmcAlmline1TrscvAlmDdm | |||
| 1.3.6.1.4.1.20044.21.2.2.2.18.1 | ScalarpmmcAlmLine1TxPwrLowAla | read-only | current | TRSCV 1 Tx Power Low :Alarm indicating that the transceiver output power of Line 1 is lower than the threshold value written in the transceiver EEPROM <Condtyp… |
| 1.3.6.1.4.1.20044.21.2.2.2.18.2 | ScalarpmmcAlmLine1TxPwrHighAla | read-only | current | TRSCV 1 Tx Power High :Alarm indicating that the transceiver output power of Line 1 is higher than the threshold value written in the transceiver EEPROM <Condt… |
| 1.3.6.1.4.1.20044.21.2.2.2.18.3 | ScalarpmmcAlmLine1TxBiasLowAla | read-only | current | TRSCV 1 Bias Low :Alarm indicating that the transceiver laser bias current of Line 1 is lower than the threshold value written in the transceiver EEPROM <Condt… |
| 1.3.6.1.4.1.20044.21.2.2.2.18.4 | ScalarpmmcAlmLine1TxBiasHighAla | read-only | current | TRSCV 1 Bias High :Alarm indicating that the transceiver laser bias current of Line 1 is higher than the threshold value written in the transceiver EEPROM <Con… |
| 1.3.6.1.4.1.20044.21.2.2.2.18.5 | ScalarpmmcAlmLine1VccLowAla | read-only | current | TRSCV 1 Power Supply Low :Alarm indicating that the transceiver power supply of Line 1 is lower than the threshold value written in the transceiver EEPROM <Con… |
| 1.3.6.1.4.1.20044.21.2.2.2.18.6 | ScalarpmmcAlmLine1VccHighAla | read-only | current | TRSCV 1 Power Supply High :Alarm indicating that the transceiver power supply of Line 1 is higher than the threshold value written in the transceiver EEPROM <C… |
| 1.3.6.1.4.1.20044.21.2.2.2.18.7 | ScalarpmmcAlmLine1TempLowAla | read-only | current | TRSCV 1 Temp Low :Alarm indicating that the transceiver temperature of Line 1 is lower than the threshold value written in the transceiver EEPROM <Condtype> LI… |
| 1.3.6.1.4.1.20044.21.2.2.2.18.8 | ScalarpmmcAlmLine1TempHighAla | read-only | current | TRSCV 1 Temp High :Alarm indicating that the transceiver temperature of Line 1 is higher than the threshold value written in the transceiver EEPROM <Condtype> … |
| 1.3.6.1.4.1.20044.21.2.2.2.18.15 | ScalarpmmcAlmLine1RxPwrLowAla | read-only | current | TRSCV 1 Rx Power Low :Alarm indicating that the transceiver input power of Line 1 is lower than the threshold value written in the transceiver EEPROM <Condtype… |
| 1.3.6.1.4.1.20044.21.2.2.2.18.16 | ScalarpmmcAlmLine1RxPwrHighAla | read-only | current | TRSCV 1 Rx Power High :Alarm indicating that the transceiver input power of Line 1 is higher than the threshold value written in the transceiver EEPROM <Condty… |
| 1.3.6.1.4.1.20044.21.2.2.3 | NodepmmcAlmClientCrit | |||
| 1.3.6.1.4.1.20044.21.2.2.3.8 | NodepmmcAlmsynthAlm8 | |||
| 1.3.6.1.4.1.20044.21.2.2.3.8.1 | ScalarpmmcAlmLine1TrscvAbsent | read-only | current | Line 1 SFP Absent :This OID indicates that the transceiver module 2 is not present. <Help> This alarm indicates if the line 1 transceiver is present. <Condtype… |
| 1.3.6.1.4.1.20044.21.2.2.3.8.2 | ScalarpmmcAlmLine1TrscvDdmAbsent | read-only | current | DDM Supported On Line 1 SFP :This OID indicates that the transceiver module 1 does not support Digital Diagnostic Monitoring Functions <Help> This status indic… |
| 1.3.6.1.4.1.20044.21.2.2.3.8.4 | ScalarpmmcAlmLine1HwFail | read-only | current | Line 1 HW Failure :This OID indicates a hardware failure on the Line 1 <Condtype> LINE1_HW_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlar… |
| 1.3.6.1.4.1.20044.21.2.2.3.8.5 | ScalarpmmcAlmLine1TrscvLsd | read-only | current | Line 1 SFP Laser Shutdown :This OID indicates the optical output power is off on Line 1 <Help> This status indicates if the line 1 transceiver laser is ON or O… |
| 1.3.6.1.4.1.20044.21.2.2.3.8.9 | ScalarpmmcAlmLine1TrscvDdmWarning | read-only | current | Warning DDM On Optical Module 1 :This OID indicates a warning is present coming out of optical interface DDM on Line 1 <Help> This alarm indicates if a DDM War… |
| 1.3.6.1.4.1.20044.21.2.2.3.8.10 | ScalarpmmcAlmLine1TrscvDdmAlm | read-only | current | Alarm DDM On Optical Module 1 :This OID indicates an alarm is present coming out of optical interface DDM on Line 1 <Help> This alarm indicates if a DDM Alarm … |
| 1.3.6.1.4.1.20044.21.2.2.3.8.12 | ScalarpmmcAlmLine1Fail | read-only | current | Line 1 Failure :This OID indicates a failure on the Line 1 <Condtype> LINE1_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12) <Polarit… |
| 1.3.6.1.4.1.20044.21.2.2.3.16 | NodepmmcAlmline1AccessioAlm | |||
| 1.3.6.1.4.1.20044.21.2.2.3.16.1 | ScalarpmmcAlmLine1LasFail | read-only | current | Line 1 SFP Tx Failed :This OID indicates that the transmitter fails for the transceiver plugged into the Line 1 (this alarm reports the transmitter failure ala… |
| 1.3.6.1.4.1.20044.21.2.2.3.16.4 | ScalarpmmcAlmLine1Los | read-only | current | Loss Of Optical Signal On Line 1 :This OID indicates that no signal is present on the transceiver 1 <Help> This alarm indicates if an optical signal is detecte… |
| 1.3.6.1.4.1.20044.21.2.3 | NodepmmcAlmLine | |||
| 1.3.6.1.4.1.20044.21.2.3.1 | NodepmmcAlmLineNurg | |||
| 1.3.6.1.4.1.20044.21.2.3.1.28 | NodepmmcAlmline2TrscvWarnDdm | |||
| 1.3.6.1.4.1.20044.21.2.3.1.28.1 | ScalarpmmcAlmLine2TxPwLowWng | read-only | current | TRSCV 2 Tx Power Low Warning :Warning indicating that the transceiver output power of Line 2 is lower than the threshold value written in the transceiver EEPRO… |
| 1.3.6.1.4.1.20044.21.2.3.1.28.2 | ScalarpmmcAlmLine2TxPwrHighWng | read-only | current | TRSCV 2 Tx Power High Warning :Warning indicating that the transceiver output power of Line 2 is higher than the threshold value written in the transceiver EEP… |
| 1.3.6.1.4.1.20044.21.2.3.1.28.3 | ScalarpmmcAlmLine2TxBiasLowWng | read-only | current | TRSCV 2 Bias Low Warning :Warning indicating that the transceiver laser bias current of Line 2 is lower than the threshold value written in the transceiver EEP… |
| 1.3.6.1.4.1.20044.21.2.3.1.28.4 | ScalarpmmcAlmLine2TxBiasHighWng | read-only | current | TRSCV 2 Bias High Warning :Warning indicating that the transceiver laser bias current of Line 2 is higher than the threshold value written in the transceiver E… |
| 1.3.6.1.4.1.20044.21.2.3.1.28.5 | ScalarpmmcAlmLine2VccLowWng | read-only | current | TRSCV 2 Power Supply Low Warning :Warning indicating that the transceiver power supply of Line 2 is lower than the threshold value written in the transceiver E… |
| 1.3.6.1.4.1.20044.21.2.3.1.28.6 | ScalarpmmcAlmLine2VccHighWng | read-only | current | TRSCV 2 Power Supply High Warning :Warning indicating that the transceiver power supply of Line 2 is higher than the threshold value written in the transceiver… |
| 1.3.6.1.4.1.20044.21.2.3.1.28.7 | ScalarpmmcAlmLine2TempLowWng | read-only | current | TRSCV 2 Temp Low Warning :Warning indicating that the transceiver temperature of Line 2 is lower than the threshold value written in the transceiver EEPROM <Co… |
| 1.3.6.1.4.1.20044.21.2.3.1.28.8 | ScalarpmmcAlmLine2TempHighWng | read-only | current | TRSCV 2 Temp High Warning :Warning indicating that the transceiver temperature of Line 2 is higher than the threshold value written in the transceiver EEPROM <… |
| 1.3.6.1.4.1.20044.21.2.3.1.28.15 | ScalarpmmcAlmLine2RxPwrLowWng | read-only | current | TRSCV 2 Rx Power Low Warning :Warning indicating that the transceiver input power of Line 2 is lower than the threshold value written in the transceiver EEPROM… |
| 1.3.6.1.4.1.20044.21.2.3.1.28.16 | ScalarpmmcAlmLine2RxPwrHighWng | read-only | current | TRSCV 2 Rx Power High Warning :Warning indicating that the transceiver input power of Line 2 is higher than the threshold value written in the transceiver EEPR… |
| 1.3.6.1.4.1.20044.21.2.3.1.31 | NodepmmcAlmline2CdrAlm | |||
| 1.3.6.1.4.1.20044.21.2.3.1.31.1 | ScalarpmmcAlmLine2CdrLossofsignal | read-only | current | Line 2 CDR Loss Of Signal :This OID indicates that a Loss of electrical signal is detected on the Line 2 CDR <Help> This alarm indicates if an electrical signa… |
| 1.3.6.1.4.1.20044.21.2.3.1.31.2 | ScalarpmmcAlmLine2CdrLossoflock | read-only | current | Line 2 CDR Loss Of Lock :This OID indicates that the Line 2 CDR is not locked <Help> This alarm indicates if Line 2 CDR is correclty locked on the input signal… |
| 1.3.6.1.4.1.20044.21.2.3.1.31.3 | ScalarpmmcAlmLine2CdrRefAbsent | read-only | current | Line 2 CDR Reference Clock Absent :This OID indicates that the CDR reference clock is absent on Line 2 <Help> This alarm indicates if the reference clock is pr… |
| 1.3.6.1.4.1.20044.21.2.3.2 | NodepmmcAlmLineUrg | |||
| 1.3.6.1.4.1.20044.21.2.3.2.26 | NodepmmcAlmline2TrscvAlmDdm | |||
| 1.3.6.1.4.1.20044.21.2.3.2.26.1 | ScalarpmmcAlmLine2TxPwrLowAla | read-only | current | TRSCV 2 Tx Power Low :Alarm indicating that the transceiver output power of Line 2 is lower than the threshold value written in the transceiver EEPROM <Condtyp… |
| 1.3.6.1.4.1.20044.21.2.3.2.26.2 | ScalarpmmcAlmLine2TxPwrHighAla | read-only | current | TRSCV 2 Tx Power High :Alarm indicating that the transceiver output power of Line 2 is higher than the threshold value written in the transceiver EEPROM <Condt… |
| 1.3.6.1.4.1.20044.21.2.3.2.26.3 | ScalarpmmcAlmLine2TxBiasLowAla | read-only | current | TRSCV 2 Bias Low :Alarm indicating that the transceiver laser bias current of Line 2 is lower than the threshold value written in the transceiver EEPROM <Condt… |
| 1.3.6.1.4.1.20044.21.2.3.2.26.4 | ScalarpmmcAlmLine2TxBiasHighAla | read-only | current | TRSCV 2 Bias High :Alarm indicating that the transceiver laser bias current of Line 2 is higher than the threshold value written in the transceiver EEPROM <Con… |
| 1.3.6.1.4.1.20044.21.2.3.2.26.5 | ScalarpmmcAlmLine2VccLowAla | read-only | current | TRSCV 2 Power Supply Low :Alarm indicating that the transceiver power supply of Line 2 is lower than the threshold value written in the transceiver EEPROM <Con… |
| 1.3.6.1.4.1.20044.21.2.3.2.26.6 | ScalarpmmcAlmLine2VccHighAla | read-only | current | TRSCV 2 Power Supply High :Alarm indicating that the transceiver power supply of Line 2 is higher than the threshold value written in the transceiver EEPROM <C… |
| 1.3.6.1.4.1.20044.21.2.3.2.26.7 | ScalarpmmcAlmLine2TempLowAla | read-only | current | TRSCV 2 Temp Low :Alarm indicating that the transceiver temperature of Line 2 is lower than the threshold value written in the transceiver EEPROM <Condtype> LI… |
| 1.3.6.1.4.1.20044.21.2.3.2.26.8 | ScalarpmmcAlmLine2TempHighAla | read-only | current | TRSCV 2 Temp High :Alarm indicating that the transceiver temperature of Line 2 is higher than the threshold value written in the transceiver EEPROM <Condtype> … |
| 1.3.6.1.4.1.20044.21.2.3.2.26.15 | ScalarpmmcAlmLine2RxPwrLowAla | read-only | current | TRSCV 2 Rx Power Low :Alarm indicating that the transceiver input power of Line 2 is lower than the threshold value written in the transceiver EEPROM <Condtype… |
| 1.3.6.1.4.1.20044.21.2.3.2.26.16 | ScalarpmmcAlmLine2RxPwrHighAla | read-only | current | TRSCV 2 Rx Power High :Alarm indicating that the transceiver input power of Line 2 is higher than the threshold value written in the transceiver EEPROM <Condty… |
| 1.3.6.1.4.1.20044.21.2.3.3 | NodepmmcAlmLineCrit | |||
| 1.3.6.1.4.1.20044.21.2.3.3.7 | NodepmmcAlmsynthAlm7 | |||
| 1.3.6.1.4.1.20044.21.2.3.3.7.1 | ScalarpmmcAlmLine2TrscvAbsent | read-only | current | Line 2 SFP Absent :This OID indicates that the transceiver module 2 is not present. <Help> This alarm indicates if the line 2 transceiver is present. <Condtype… |
| 1.3.6.1.4.1.20044.21.2.3.3.7.2 | ScalarpmmcAlmLine2TrscvDdmAbsent | read-only | current | DDM Supported On Line 2 SFP :This OID indicates that the transceiver module 2 does not support Digital Diagnostic Monitoring Functions <Help> This status indic… |
| 1.3.6.1.4.1.20044.21.2.3.3.7.4 | ScalarpmmcAlmLine2HwFail | read-only | current | Line 2 HW Failure :This OID indicates a hardware failure on the Line 2 <Condtype> LINE2_HW_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlar… |
| 1.3.6.1.4.1.20044.21.2.3.3.7.5 | ScalarpmmcAlmLine2TrscvLsd | read-only | current | Line 2 SFP Laser Shutdown :This OID indicates the optical output power is off on Line 2 <Help> This status indicates if the line 2 transceiver laser is ON or O… |
| 1.3.6.1.4.1.20044.21.2.3.3.7.9 | ScalarpmmcAlmLine2TrscvDdmWarning | read-only | current | Warning DDM On Optical Module 2 :This OID indicates a warning is present coming out of optical interface DDM on Line 2 <Help> This alarm indicates if a DDM War… |
| 1.3.6.1.4.1.20044.21.2.3.3.7.10 | ScalarpmmcAlmLine2TrscvDdmAlm | read-only | current | Alarm DDM On Optical Module 2 :This OID indicates an alarm is present coming out of optical interface DDM on Line 2 <Help> This alarm indicates if a DDM Alarm … |
| 1.3.6.1.4.1.20044.21.2.3.3.7.12 | ScalarpmmcAlmLine2Fail | read-only | current | Line 2 Failure :This OID indicates a failure on the Line 2 <Condtype> LINE2_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12) <Polarit… |
| 1.3.6.1.4.1.20044.21.2.3.3.24 | NodepmmcAlmline2AccessioAlm | |||
| 1.3.6.1.4.1.20044.21.2.3.3.24.1 | ScalarpmmcAlmLine2LasFail | read-only | current | Line 2 SFP Tx Failed :This OID indicates that the transmitter fails for the transceiver plugged into the Line 1 (this alarm reports the transmitter failure ala… |
| 1.3.6.1.4.1.20044.21.2.3.3.24.4 | ScalarpmmcAlmLine2Los | read-only | current | Loss Of Optical Signal On Line 2 :This OID indicates that no signal is present on the transceiver 2 <Help> This alarm indicates if an optical signal is detecte… |
| 1.3.6.1.4.1.20044.21.3 | Nodepmmcmeasures | |||
| 1.3.6.1.4.1.20044.21.3.1 | NodepmmcMesrOther | |||
| 1.3.6.1.4.1.20044.21.3.2 | NodepmmcMesrClient | |||
| 1.3.6.1.4.1.20044.21.3.2.16 | ScalarpmmcMesrline1Temperature | read-only | current | Line 1 SFP Temperature :This OID gives the temperature of the transceiver Line 1, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Uni… |
| 1.3.6.1.4.1.20044.21.3.2.17 | ScalarpmmcMesrline1Volt | read-only | current | Line 1 SFP Power Supply :This OID gives the voltage of the transceiver Line 1, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/10000) (Unit = V… |
| 1.3.6.1.4.1.20044.21.3.2.18 | ScalarpmmcMesrline1TxBias | read-only | current | Line 1 SFP Laser Bias :This OID gives the bias value of the transceiver Line 1, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <… |
| 1.3.6.1.4.1.20044.21.3.2.19 | ScalarpmmcMesrline1TxPower | read-only | current | Line 1 SFP Tx Power :This OID gives the transmit power value of the transceiver Line 1, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-4… |
| 1.3.6.1.4.1.20044.21.3.2.20 | ScalarpmmcMesrline1RxPower | read-only | current | Line 1 SFP Rx Power :This OID gives the receive power value of the transceiver Line 1, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40… |
| 1.3.6.1.4.1.20044.21.3.3 | NodepmmcMesrLine | |||
| 1.3.6.1.4.1.20044.21.3.3.24 | ScalarpmmcMesrline2Temperature | read-only | current | Line 2 SFP Temperature :This OID gives the temperature of the transceiver Line 2, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Uni… |
| 1.3.6.1.4.1.20044.21.3.3.25 | ScalarpmmcMesrline2Volt | read-only | current | Line 2 SFP Power Supply :This OID gives the voltage of the transceiver Line 2, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/10000) (Unit = V… |
| 1.3.6.1.4.1.20044.21.3.3.26 | ScalarpmmcMesrline2TxBias | read-only | current | Line 2 SFP Laser Bias :This OID gives the bias value of the transceiver Line 2, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <… |
| 1.3.6.1.4.1.20044.21.3.3.27 | ScalarpmmcMesrline2TxPower | read-only | current | Line 2 SFP Tx Power :This OID gives the transmit power value of the transceiver Line 2, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-4… |
| 1.3.6.1.4.1.20044.21.3.3.28 | ScalarpmmcMesrline2RxPower | read-only | current | Line 2 SFP Rx Power :This OID gives the receive power value of the transceiver Line 2, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40… |
| 1.3.6.1.4.1.20044.21.6 | NodepmmccontrolsWrite | |||
| 1.3.6.1.4.1.20044.21.6.1 | NodepmmcCtrlOther | |||
| 1.3.6.1.4.1.20044.21.6.1.0 | NodepmmcCtrlsynth0 | |||
| 1.3.6.1.4.1.20044.21.6.1.0.1 | ScalarpmmcCtrlConfLoad | read-write | current | Load Configuration Tables :When set this enables loading from flash configuration1 into the module. |
| 1.3.6.1.4.1.20044.21.6.1.0.9 | ScalarpmmcCtrlConfFlash | read-write | current | Write Configuration Tables :This bit saves the current configuration of the module as configuration in the flash. <Help> This control saves the customer config… |
| 1.3.6.1.4.1.20044.21.6.1.0.13 | ScalarpmmcCtrlConfClear | read-write | current | Clear Configuration Tables :This bit clears the configuration tables from configuration in the flash. <Help> This control restores the default configuration of… |
| 1.3.6.1.4.1.20044.21.6.1.4 | NodepmmcCtrlsynth4 | |||
| 1.3.6.1.4.1.20044.21.6.1.4.1 | ScalarpmmcCtrlCorrelatOn | read-write | current | Enable Alarm Correlation :This OID enables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.21.6.1.4.2 | ScalarpmmcCtrlCorrelatOff | read-write | current | Disable Alarm Correlation :This OID disables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.21.6.1.5 | NodepmmcCtrlswMgnt | |||
| 1.3.6.1.4.1.20044.21.6.1.5.2 | ScalarpmmcCtrlColdReset | read-write | current | PM Cold Reset :This OID, when set, causes a cold reset of the Software. This reset is traffic affecting, and the configuration of Software is reloaded on start… |
| 1.3.6.1.4.1.20044.21.6.1.5.3 | ScalarpmmcCtrlWarmReset | read-write | current | PM Warm Reset :This OID, when set, causes a warm reset of the Software. This reset is not traffic affecting, and the configuration of the Sofwtare remains unch… |
| 1.3.6.1.4.1.20044.21.6.1.64 | NodepmmcCtrlledTest | |||
| 1.3.6.1.4.1.20044.21.6.1.64.1 | ScalarpmmcCtrlGreenLed | read-write | current | Green Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green |
| 1.3.6.1.4.1.20044.21.6.1.64.2 | ScalarpmmcCtrlRedLed | read-write | current | Red Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red |
| 1.3.6.1.4.1.20044.21.6.1.64.3 | ScalarpmmcCtrlLedOff | read-write | current | Leds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF |
| 1.3.6.1.4.1.20044.21.6.2 | NodepmmcCtrlClient | |||
| 1.3.6.1.4.1.20044.21.6.2.16 | NodepmmcCtrlline1TrscvOnoff | |||
| 1.3.6.1.4.1.20044.21.6.2.16.1 | ScalarpmmcCtrlLine1TrscvOnoff | read-write | current | Line 1 SFP Laser Shutdown :This OID switches off the transceiver on Line 1 <Help> This control defines the laser state of the line 1 transceiver |
| 1.3.6.1.4.1.20044.21.6.3 | NodepmmcCtrlLine | |||
| 1.3.6.1.4.1.20044.21.6.3.24 | NodepmmcCtrlline2TrscvOnoff | |||
| 1.3.6.1.4.1.20044.21.6.3.24.1 | ScalarpmmcCtrlLine2TrscvOnoff | read-write | current | Line 2 SFP Laser Shutdown :This OID switches off the transceiver on Line 2 <Help> This control defines the laser state of the line 2 transceiver |
| 1.3.6.1.4.1.20044.21.7 | Nodepmmcri | |||
| 1.3.6.1.4.1.20044.21.7.2 | ScalarpmmcRinvReloadInventory | read-write | current | Reload the inventory: This OID triggers an inventory reload. |
| 1.3.6.1.4.1.20044.21.7.4 | ScalarpmmcRinvHwPlatform | read-only | current | Module platform description: This OID contains the description of the Module. |
| 1.3.6.1.4.1.20044.21.7.5 | ScalarpmmcRinvSwPlatform | read-only | current | SW platform description: This OID contains the description of the Software platform. |
| 1.3.6.1.4.1.20044.21.7.6 | ScalarpmmcRinvLine1SFP | read-only | current | Inventory for the SFP: This OID contains the inventory for the Port A SFP |
| 1.3.6.1.4.1.20044.21.7.7 | ScalarpmmcRinvLine2SFP | read-only | current | Inventory for the SFP: This OID contains the inventory for the Port B SFP |
| 1.3.6.1.4.1.20044.21.9 | NodepmmcConfig | |||
| 1.3.6.1.4.1.20044.21.9.1 | NodepmmcCfgLsd | |||
| 1.3.6.1.4.1.20044.21.9.1.1 | NodepmmctableclientLsd | |||
| 1.3.6.1.4.1.20044.21.9.1.1.2 | ScalarpmmcCfglsdMode | read-write | current | CAIS mode on Lines Port :This register selects the way to activate the laser upon CAIS/CSF criteria detection on Port |
| 1.3.6.1.4.1.20044.21.9.1.1.3 | ScalarpmmcCfgline1AccessioCtrb | read-write | current | CAIS contributors on Line 1 Port :This register selects the contributors to upstream CAIS/CSF on Port |
| 1.3.6.1.4.1.20044.21.9.1.1.4 | ScalarpmmcCfgline1CdrCtrb | read-write | current | CAIS contributors on Line 1 Port :This register selects the contributors to upstream CAIS/CSF on Port |
| 1.3.6.1.4.1.20044.21.9.1.1.5 | ScalarpmmcCfgline2AccessioCtrb | read-write | current | CAIS contributors on Line 2 Port :This register selects the contributors to downstream CAIS/CSF on Port |
| 1.3.6.1.4.1.20044.21.9.1.1.6 | ScalarpmmcCfgline2CdrCtrb | read-write | current | CAIS contributors on Line 2 Port :This register selects the contributors to downstream CAIS/CSF on Port |
| 1.3.6.1.4.1.20044.21.9.2 | NodepmmcCfgStartUp | |||
| 1.3.6.1.4.1.20044.21.9.2.1 | NodepmmctableclientStartup | |||
| 1.3.6.1.4.1.20044.21.9.2.1.2 | ScalarpmmcCfgline1TrscvCtrl | read-write | current | Default Settings on Line 1 :This register configures the default initialisation settings on Line 1. |
| 1.3.6.1.4.1.20044.21.9.2.2 | NodepmmctablelineStartup | |||
| 1.3.6.1.4.1.20044.21.9.2.2.2 | ScalarpmmcCfgline2TrscvCtrl | read-write | current | Default Settings on Line 2 :This register configures the default initialisation settings on Line 2. |
| 1.3.6.1.4.1.20044.21.9.2.2.18 | ScalarpmmcCfgbitrateSelect | read-write | current | Bitrate selection on Line 1/2 :This OID register configure the bitrate for the client and line interface (0=STS48 : 2,4 to 2,7 Gb/s - 1=1GBE : 1,2 to 1,35 Gb/s… |
| 1.3.6.1.4.1.20044.21.9.3 | NodepmmcCfgLabels | |||
| 1.3.6.1.4.1.20044.21.9.3.1 | TablepmmcCfgLabelclientTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.21.9.3.1.1 | RowpmmcCfgLabelclientEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.21.9.3.1.1.1 | ColumnpmmcCfgLabelclientIndex | read-only | current | Index definition for the labelclient table |
| 1.3.6.1.4.1.20044.21.9.3.1.1.3 | ColumnpmmcCfgLabelclientPortn | read-write | current | Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. |
| 1.3.6.1.4.1.20044.21.9.3.2 | TablepmmcCfgLabellineTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.21.9.3.2.1 | RowpmmcCfgLabellineEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.21.9.3.2.1.1 | ColumnpmmcCfgLabellineIndex | read-only | current | Index definition for the labelline table |
| 1.3.6.1.4.1.20044.21.9.3.2.1.3 | ColumnpmmcCfgLabellinePortn | read-write | current | Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. |
| 1.3.6.1.4.1.20044.21.9.257 | ScalarpmmcCfgWriteConfiguration | read-write | current | Write configuration to module:This OID writes the complete configuration to the module |
| 1.3.6.1.4.1.20044.21.10 | Nodepmmctraps | |||
| 1.3.6.1.4.1.20044.21.10.4 | ScalarpmmctrapBoardNumber | read-only | current | Last module which generates a trap |
| 1.3.6.1.4.1.20044.21.10.30 | NotificationpmmcLine1TrapNotUrgentGoesOn | current | Not urgent Line 1 default is activated | |
| 1.3.6.1.4.1.20044.21.10.31 | NotificationpmmcLine1TrapNotUrgentGoesOff | current | Not urgent Line 1 default disappeared | |
| 1.3.6.1.4.1.20044.21.10.32 | NotificationpmmcLine1TrapUrgentGoesOn | current | Urgent Line 1 default is activated | |
| 1.3.6.1.4.1.20044.21.10.33 | NotificationpmmcLine1TrapUrgentGoesOff | current | Urgent Line 1 default disappeared | |
| 1.3.6.1.4.1.20044.21.10.34 | NotificationpmmcLine1TrapCritGoesOn | current | Critical Line 1 default is activated | |
| 1.3.6.1.4.1.20044.21.10.35 | NotificationpmmcLine1TrapCritGoesOff | current | Critical Line 1 default disappeared | |
| 1.3.6.1.4.1.20044.21.10.40 | NotificationpmmcLine2NotUrgentGoesOn | current | Not urgent Line 2 default is activated | |
| 1.3.6.1.4.1.20044.21.10.41 | NotificationpmmcLine2NotUrgentGoesOff | current | Not urgent Line 2 default disappeared | |
| 1.3.6.1.4.1.20044.21.10.42 | NotificationpmmcLine2UrgentGoesOn | current | Urgent Line 2 default is activated | |
| 1.3.6.1.4.1.20044.21.10.43 | NotificationpmmcLine2UrgentGoesOff | current | Urgent Line 2 default disappeared | |
| 1.3.6.1.4.1.20044.21.10.44 | NotificationpmmcLine2CritGoesOn | current | Critical Line 2 default is activated | |
| 1.3.6.1.4.1.20044.21.10.45 | NotificationpmmcLine2CritGoesOff | current | Critical Line 2 default disappeared | |
| 1.3.6.1.4.1.20044.21.10.50 | NotificationpmmcPowerTrapUrgentGoesOn | current | Urgent power supply default is activated | |
| 1.3.6.1.4.1.20044.21.10.51 | NotificationpmmcPowerTrapUrgentGoesOff | current | Urgent power supply default disappeared |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| PmmcBitRate | INTEGER { rateSTM16OC48(0), rate1GBE(1), rateSTM4OC12(2), rateSTM1OC3(3), rate2GFC(4), rate1GFC(5), rateFastEthernet(7), rateSTM16FEC(8), rateSTM4FEC(9), rateSTM1FEC(10) } | current | different rates for a client and line ports |