EKINOPS-PmMC-MIB

176 objects
MIB for the Ekinops Pmmc hardware.
OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.21IdentitymodulePmMCMIB for the Ekinops Pmmc hardware.
1.3.6.1.4.1.20044.21.2Nodepmmcalarms
1.3.6.1.4.1.20044.21.2.1NodepmmcAlmOther
1.3.6.1.4.1.20044.21.2.1.1NodepmmcAlmOtherNurg
1.3.6.1.4.1.20044.21.2.1.2NodepmmcAlmOtherUrg
1.3.6.1.4.1.20044.21.2.1.3NodepmmcAlmOtherCrit
1.3.6.1.4.1.20044.21.2.1.3.0NodepmmcAlmsynthAlm0
1.3.6.1.4.1.20044.21.2.1.3.0.9ScalarpmmcAlmModuleGlobFailureread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the PM <Condtype> MODULE_GLOB_FAILURE <Probcause> equipmentMalfunction (16) <Alarmty…
1.3.6.1.4.1.20044.21.2.1.3.0.14ScalarpmmcAlmSynUnlockread-onlycurrentSynthesizer Not Locked :This OID indicates that the frequency synthesizer is not locked. <Help> This status indicates if the clock synthesizer is locked. <Cond…
1.3.6.1.4.1.20044.21.2.1.3.0.15ScalarpmmcAlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.21.2.1.3.0.16ScalarpmmcAlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.21.2.2NodepmmcAlmClient
1.3.6.1.4.1.20044.21.2.2.1NodepmmcAlmClientNurg
1.3.6.1.4.1.20044.21.2.2.1.20NodepmmcAlmline1TrscvWarnDdm
1.3.6.1.4.1.20044.21.2.2.1.20.1ScalarpmmcAlmLine1TxPwLowWngread-onlycurrentTRSCV 1 Tx Power Low Warning :Warning indicating that the transceiver output power of Line 1 is lower than the threshold value written in the transceiver EEPRO…
1.3.6.1.4.1.20044.21.2.2.1.20.2ScalarpmmcAlmLine1TxPwrHighWngread-onlycurrentTRSCV 1 Tx Power High Warning :Warning indicating that the transceiver output power of Line 1 is higher than the threshold value written in the transceiver EEP…
1.3.6.1.4.1.20044.21.2.2.1.20.3ScalarpmmcAlmLine1TxBiasLowWngread-onlycurrentTRSCV 1 Bias Low Warning :Warning indicating that the transceiver laser bias current of Line 1 is lower than the threshold value written in the transceiver EEP…
1.3.6.1.4.1.20044.21.2.2.1.20.4ScalarpmmcAlmLine1TxBiasHighWngread-onlycurrentTRSCV 1 Bias High Warning :Warning indicating that the transceiver laser bias current of Line 1 is higher than the threshold value written in the transceiver E…
1.3.6.1.4.1.20044.21.2.2.1.20.5ScalarpmmcAlmLine1VccLowWngread-onlycurrentTRSCV 1 Power Supply Low Warning :Warning indicating that the transceiver power supply of Line 1 is lower than the threshold value written in the transceiver E…
1.3.6.1.4.1.20044.21.2.2.1.20.6ScalarpmmcAlmLine1VccHighWngread-onlycurrentTRSCV 1 Power Supply High Warning :Warning indicating that the transceiver power supply of Line 1 is higher than the threshold value written in the transceiver…
1.3.6.1.4.1.20044.21.2.2.1.20.7ScalarpmmcAlmLine1TempLowWngread-onlycurrentTRSCV 1 Temp Low Warning :Warning indicating that the transceiver temperature of Line 1 is lower than the threshold value written in the transceiver EEPROM <Co…
1.3.6.1.4.1.20044.21.2.2.1.20.8ScalarpmmcAlmLine1TempHighWngread-onlycurrentTRSCV 1 Temp High Warning :Warning indicating that the transceiver temperature of Line 1 is higher than the threshold value written in the transceiver EEPROM <…
1.3.6.1.4.1.20044.21.2.2.1.20.15ScalarpmmcAlmLine1RxPwrLowWngread-onlycurrentTRSCV 1 Rx Power Low Warning :Warning indicating that the transceiver input power of Line 1 is lower than the threshold value written in the transceiver EEPROM…
1.3.6.1.4.1.20044.21.2.2.1.20.16ScalarpmmcAlmLine1RxPwrHighWngread-onlycurrentTRSCV 1 Rx Power High Warning :Warning indicating that the transceiver input power of Line 1 is higher than the threshold value written in the transceiver EEPR…
1.3.6.1.4.1.20044.21.2.2.1.23NodepmmcAlmline1CdrAlm
1.3.6.1.4.1.20044.21.2.2.1.23.1ScalarpmmcAlmLine1CdrLossofsignalread-onlycurrentLine 1 CDR Loss Of Signal :This OID indicates that a Loss of electrical signal is detected on the Line 1 CDR <Help> This alarm indicates if an electrical signa…
1.3.6.1.4.1.20044.21.2.2.1.23.2ScalarpmmcAlmLine1CdrLossoflockread-onlycurrentLine 1 CDR Loss Of Lock :This OID indicates that the Line 1 CDR is not locked <Help> This alarm indicates if Line 1 CDR is correclty locked on the input signal…
1.3.6.1.4.1.20044.21.2.2.1.23.3ScalarpmmcAlmLine1CdrRefAbsentread-onlycurrentLine 1 CDR Reference Clock Absent :This OID indicates that the CDR reference clock is absent on Line 1 <Help> This alarm indicates if the reference clock is pr…
1.3.6.1.4.1.20044.21.2.2.2NodepmmcAlmClientUrg
1.3.6.1.4.1.20044.21.2.2.2.18NodepmmcAlmline1TrscvAlmDdm
1.3.6.1.4.1.20044.21.2.2.2.18.1ScalarpmmcAlmLine1TxPwrLowAlaread-onlycurrentTRSCV 1 Tx Power Low :Alarm indicating that the transceiver output power of Line 1 is lower than the threshold value written in the transceiver EEPROM <Condtyp…
1.3.6.1.4.1.20044.21.2.2.2.18.2ScalarpmmcAlmLine1TxPwrHighAlaread-onlycurrentTRSCV 1 Tx Power High :Alarm indicating that the transceiver output power of Line 1 is higher than the threshold value written in the transceiver EEPROM <Condt…
1.3.6.1.4.1.20044.21.2.2.2.18.3ScalarpmmcAlmLine1TxBiasLowAlaread-onlycurrentTRSCV 1 Bias Low :Alarm indicating that the transceiver laser bias current of Line 1 is lower than the threshold value written in the transceiver EEPROM <Condt…
1.3.6.1.4.1.20044.21.2.2.2.18.4ScalarpmmcAlmLine1TxBiasHighAlaread-onlycurrentTRSCV 1 Bias High :Alarm indicating that the transceiver laser bias current of Line 1 is higher than the threshold value written in the transceiver EEPROM <Con…
1.3.6.1.4.1.20044.21.2.2.2.18.5ScalarpmmcAlmLine1VccLowAlaread-onlycurrentTRSCV 1 Power Supply Low :Alarm indicating that the transceiver power supply of Line 1 is lower than the threshold value written in the transceiver EEPROM <Con…
1.3.6.1.4.1.20044.21.2.2.2.18.6ScalarpmmcAlmLine1VccHighAlaread-onlycurrentTRSCV 1 Power Supply High :Alarm indicating that the transceiver power supply of Line 1 is higher than the threshold value written in the transceiver EEPROM <C…
1.3.6.1.4.1.20044.21.2.2.2.18.7ScalarpmmcAlmLine1TempLowAlaread-onlycurrentTRSCV 1 Temp Low :Alarm indicating that the transceiver temperature of Line 1 is lower than the threshold value written in the transceiver EEPROM <Condtype> LI…
1.3.6.1.4.1.20044.21.2.2.2.18.8ScalarpmmcAlmLine1TempHighAlaread-onlycurrentTRSCV 1 Temp High :Alarm indicating that the transceiver temperature of Line 1 is higher than the threshold value written in the transceiver EEPROM <Condtype> …
1.3.6.1.4.1.20044.21.2.2.2.18.15ScalarpmmcAlmLine1RxPwrLowAlaread-onlycurrentTRSCV 1 Rx Power Low :Alarm indicating that the transceiver input power of Line 1 is lower than the threshold value written in the transceiver EEPROM <Condtype…
1.3.6.1.4.1.20044.21.2.2.2.18.16ScalarpmmcAlmLine1RxPwrHighAlaread-onlycurrentTRSCV 1 Rx Power High :Alarm indicating that the transceiver input power of Line 1 is higher than the threshold value written in the transceiver EEPROM <Condty…
1.3.6.1.4.1.20044.21.2.2.3NodepmmcAlmClientCrit
1.3.6.1.4.1.20044.21.2.2.3.8NodepmmcAlmsynthAlm8
1.3.6.1.4.1.20044.21.2.2.3.8.1ScalarpmmcAlmLine1TrscvAbsentread-onlycurrentLine 1 SFP Absent :This OID indicates that the transceiver module 2 is not present. <Help> This alarm indicates if the line 1 transceiver is present. <Condtype…
1.3.6.1.4.1.20044.21.2.2.3.8.2ScalarpmmcAlmLine1TrscvDdmAbsentread-onlycurrentDDM Supported On Line 1 SFP :This OID indicates that the transceiver module 1 does not support Digital Diagnostic Monitoring Functions <Help> This status indic…
1.3.6.1.4.1.20044.21.2.2.3.8.4ScalarpmmcAlmLine1HwFailread-onlycurrentLine 1 HW Failure :This OID indicates a hardware failure on the Line 1 <Condtype> LINE1_HW_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlar…
1.3.6.1.4.1.20044.21.2.2.3.8.5ScalarpmmcAlmLine1TrscvLsdread-onlycurrentLine 1 SFP Laser Shutdown :This OID indicates the optical output power is off on Line 1 <Help> This status indicates if the line 1 transceiver laser is ON or O…
1.3.6.1.4.1.20044.21.2.2.3.8.9ScalarpmmcAlmLine1TrscvDdmWarningread-onlycurrentWarning DDM On Optical Module 1 :This OID indicates a warning is present coming out of optical interface DDM on Line 1 <Help> This alarm indicates if a DDM War…
1.3.6.1.4.1.20044.21.2.2.3.8.10ScalarpmmcAlmLine1TrscvDdmAlmread-onlycurrentAlarm DDM On Optical Module 1 :This OID indicates an alarm is present coming out of optical interface DDM on Line 1 <Help> This alarm indicates if a DDM Alarm …
1.3.6.1.4.1.20044.21.2.2.3.8.12ScalarpmmcAlmLine1Failread-onlycurrentLine 1 Failure :This OID indicates a failure on the Line 1 <Condtype> LINE1_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12) <Polarit…
1.3.6.1.4.1.20044.21.2.2.3.16NodepmmcAlmline1AccessioAlm
1.3.6.1.4.1.20044.21.2.2.3.16.1ScalarpmmcAlmLine1LasFailread-onlycurrentLine 1 SFP Tx Failed :This OID indicates that the transmitter fails for the transceiver plugged into the Line 1 (this alarm reports the transmitter failure ala…
1.3.6.1.4.1.20044.21.2.2.3.16.4ScalarpmmcAlmLine1Losread-onlycurrentLoss Of Optical Signal On Line 1 :This OID indicates that no signal is present on the transceiver 1 <Help> This alarm indicates if an optical signal is detecte…
1.3.6.1.4.1.20044.21.2.3NodepmmcAlmLine
1.3.6.1.4.1.20044.21.2.3.1NodepmmcAlmLineNurg
1.3.6.1.4.1.20044.21.2.3.1.28NodepmmcAlmline2TrscvWarnDdm
1.3.6.1.4.1.20044.21.2.3.1.28.1ScalarpmmcAlmLine2TxPwLowWngread-onlycurrentTRSCV 2 Tx Power Low Warning :Warning indicating that the transceiver output power of Line 2 is lower than the threshold value written in the transceiver EEPRO…
1.3.6.1.4.1.20044.21.2.3.1.28.2ScalarpmmcAlmLine2TxPwrHighWngread-onlycurrentTRSCV 2 Tx Power High Warning :Warning indicating that the transceiver output power of Line 2 is higher than the threshold value written in the transceiver EEP…
1.3.6.1.4.1.20044.21.2.3.1.28.3ScalarpmmcAlmLine2TxBiasLowWngread-onlycurrentTRSCV 2 Bias Low Warning :Warning indicating that the transceiver laser bias current of Line 2 is lower than the threshold value written in the transceiver EEP…
1.3.6.1.4.1.20044.21.2.3.1.28.4ScalarpmmcAlmLine2TxBiasHighWngread-onlycurrentTRSCV 2 Bias High Warning :Warning indicating that the transceiver laser bias current of Line 2 is higher than the threshold value written in the transceiver E…
1.3.6.1.4.1.20044.21.2.3.1.28.5ScalarpmmcAlmLine2VccLowWngread-onlycurrentTRSCV 2 Power Supply Low Warning :Warning indicating that the transceiver power supply of Line 2 is lower than the threshold value written in the transceiver E…
1.3.6.1.4.1.20044.21.2.3.1.28.6ScalarpmmcAlmLine2VccHighWngread-onlycurrentTRSCV 2 Power Supply High Warning :Warning indicating that the transceiver power supply of Line 2 is higher than the threshold value written in the transceiver…
1.3.6.1.4.1.20044.21.2.3.1.28.7ScalarpmmcAlmLine2TempLowWngread-onlycurrentTRSCV 2 Temp Low Warning :Warning indicating that the transceiver temperature of Line 2 is lower than the threshold value written in the transceiver EEPROM <Co…
1.3.6.1.4.1.20044.21.2.3.1.28.8ScalarpmmcAlmLine2TempHighWngread-onlycurrentTRSCV 2 Temp High Warning :Warning indicating that the transceiver temperature of Line 2 is higher than the threshold value written in the transceiver EEPROM <…
1.3.6.1.4.1.20044.21.2.3.1.28.15ScalarpmmcAlmLine2RxPwrLowWngread-onlycurrentTRSCV 2 Rx Power Low Warning :Warning indicating that the transceiver input power of Line 2 is lower than the threshold value written in the transceiver EEPROM…
1.3.6.1.4.1.20044.21.2.3.1.28.16ScalarpmmcAlmLine2RxPwrHighWngread-onlycurrentTRSCV 2 Rx Power High Warning :Warning indicating that the transceiver input power of Line 2 is higher than the threshold value written in the transceiver EEPR…
1.3.6.1.4.1.20044.21.2.3.1.31NodepmmcAlmline2CdrAlm
1.3.6.1.4.1.20044.21.2.3.1.31.1ScalarpmmcAlmLine2CdrLossofsignalread-onlycurrentLine 2 CDR Loss Of Signal :This OID indicates that a Loss of electrical signal is detected on the Line 2 CDR <Help> This alarm indicates if an electrical signa…
1.3.6.1.4.1.20044.21.2.3.1.31.2ScalarpmmcAlmLine2CdrLossoflockread-onlycurrentLine 2 CDR Loss Of Lock :This OID indicates that the Line 2 CDR is not locked <Help> This alarm indicates if Line 2 CDR is correclty locked on the input signal…
1.3.6.1.4.1.20044.21.2.3.1.31.3ScalarpmmcAlmLine2CdrRefAbsentread-onlycurrentLine 2 CDR Reference Clock Absent :This OID indicates that the CDR reference clock is absent on Line 2 <Help> This alarm indicates if the reference clock is pr…
1.3.6.1.4.1.20044.21.2.3.2NodepmmcAlmLineUrg
1.3.6.1.4.1.20044.21.2.3.2.26NodepmmcAlmline2TrscvAlmDdm
1.3.6.1.4.1.20044.21.2.3.2.26.1ScalarpmmcAlmLine2TxPwrLowAlaread-onlycurrentTRSCV 2 Tx Power Low :Alarm indicating that the transceiver output power of Line 2 is lower than the threshold value written in the transceiver EEPROM <Condtyp…
1.3.6.1.4.1.20044.21.2.3.2.26.2ScalarpmmcAlmLine2TxPwrHighAlaread-onlycurrentTRSCV 2 Tx Power High :Alarm indicating that the transceiver output power of Line 2 is higher than the threshold value written in the transceiver EEPROM <Condt…
1.3.6.1.4.1.20044.21.2.3.2.26.3ScalarpmmcAlmLine2TxBiasLowAlaread-onlycurrentTRSCV 2 Bias Low :Alarm indicating that the transceiver laser bias current of Line 2 is lower than the threshold value written in the transceiver EEPROM <Condt…
1.3.6.1.4.1.20044.21.2.3.2.26.4ScalarpmmcAlmLine2TxBiasHighAlaread-onlycurrentTRSCV 2 Bias High :Alarm indicating that the transceiver laser bias current of Line 2 is higher than the threshold value written in the transceiver EEPROM <Con…
1.3.6.1.4.1.20044.21.2.3.2.26.5ScalarpmmcAlmLine2VccLowAlaread-onlycurrentTRSCV 2 Power Supply Low :Alarm indicating that the transceiver power supply of Line 2 is lower than the threshold value written in the transceiver EEPROM <Con…
1.3.6.1.4.1.20044.21.2.3.2.26.6ScalarpmmcAlmLine2VccHighAlaread-onlycurrentTRSCV 2 Power Supply High :Alarm indicating that the transceiver power supply of Line 2 is higher than the threshold value written in the transceiver EEPROM <C…
1.3.6.1.4.1.20044.21.2.3.2.26.7ScalarpmmcAlmLine2TempLowAlaread-onlycurrentTRSCV 2 Temp Low :Alarm indicating that the transceiver temperature of Line 2 is lower than the threshold value written in the transceiver EEPROM <Condtype> LI…
1.3.6.1.4.1.20044.21.2.3.2.26.8ScalarpmmcAlmLine2TempHighAlaread-onlycurrentTRSCV 2 Temp High :Alarm indicating that the transceiver temperature of Line 2 is higher than the threshold value written in the transceiver EEPROM <Condtype> …
1.3.6.1.4.1.20044.21.2.3.2.26.15ScalarpmmcAlmLine2RxPwrLowAlaread-onlycurrentTRSCV 2 Rx Power Low :Alarm indicating that the transceiver input power of Line 2 is lower than the threshold value written in the transceiver EEPROM <Condtype…
1.3.6.1.4.1.20044.21.2.3.2.26.16ScalarpmmcAlmLine2RxPwrHighAlaread-onlycurrentTRSCV 2 Rx Power High :Alarm indicating that the transceiver input power of Line 2 is higher than the threshold value written in the transceiver EEPROM <Condty…
1.3.6.1.4.1.20044.21.2.3.3NodepmmcAlmLineCrit
1.3.6.1.4.1.20044.21.2.3.3.7NodepmmcAlmsynthAlm7
1.3.6.1.4.1.20044.21.2.3.3.7.1ScalarpmmcAlmLine2TrscvAbsentread-onlycurrentLine 2 SFP Absent :This OID indicates that the transceiver module 2 is not present. <Help> This alarm indicates if the line 2 transceiver is present. <Condtype…
1.3.6.1.4.1.20044.21.2.3.3.7.2ScalarpmmcAlmLine2TrscvDdmAbsentread-onlycurrentDDM Supported On Line 2 SFP :This OID indicates that the transceiver module 2 does not support Digital Diagnostic Monitoring Functions <Help> This status indic…
1.3.6.1.4.1.20044.21.2.3.3.7.4ScalarpmmcAlmLine2HwFailread-onlycurrentLine 2 HW Failure :This OID indicates a hardware failure on the Line 2 <Condtype> LINE2_HW_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlar…
1.3.6.1.4.1.20044.21.2.3.3.7.5ScalarpmmcAlmLine2TrscvLsdread-onlycurrentLine 2 SFP Laser Shutdown :This OID indicates the optical output power is off on Line 2 <Help> This status indicates if the line 2 transceiver laser is ON or O…
1.3.6.1.4.1.20044.21.2.3.3.7.9ScalarpmmcAlmLine2TrscvDdmWarningread-onlycurrentWarning DDM On Optical Module 2 :This OID indicates a warning is present coming out of optical interface DDM on Line 2 <Help> This alarm indicates if a DDM War…
1.3.6.1.4.1.20044.21.2.3.3.7.10ScalarpmmcAlmLine2TrscvDdmAlmread-onlycurrentAlarm DDM On Optical Module 2 :This OID indicates an alarm is present coming out of optical interface DDM on Line 2 <Help> This alarm indicates if a DDM Alarm …
1.3.6.1.4.1.20044.21.2.3.3.7.12ScalarpmmcAlmLine2Failread-onlycurrentLine 2 Failure :This OID indicates a failure on the Line 2 <Condtype> LINE2_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12) <Polarit…
1.3.6.1.4.1.20044.21.2.3.3.24NodepmmcAlmline2AccessioAlm
1.3.6.1.4.1.20044.21.2.3.3.24.1ScalarpmmcAlmLine2LasFailread-onlycurrentLine 2 SFP Tx Failed :This OID indicates that the transmitter fails for the transceiver plugged into the Line 1 (this alarm reports the transmitter failure ala…
1.3.6.1.4.1.20044.21.2.3.3.24.4ScalarpmmcAlmLine2Losread-onlycurrentLoss Of Optical Signal On Line 2 :This OID indicates that no signal is present on the transceiver 2 <Help> This alarm indicates if an optical signal is detecte…
1.3.6.1.4.1.20044.21.3Nodepmmcmeasures
1.3.6.1.4.1.20044.21.3.1NodepmmcMesrOther
1.3.6.1.4.1.20044.21.3.2NodepmmcMesrClient
1.3.6.1.4.1.20044.21.3.2.16ScalarpmmcMesrline1Temperatureread-onlycurrentLine 1 SFP Temperature :This OID gives the temperature of the transceiver Line 1, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Uni…
1.3.6.1.4.1.20044.21.3.2.17ScalarpmmcMesrline1Voltread-onlycurrentLine 1 SFP Power Supply :This OID gives the voltage of the transceiver Line 1, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/10000) (Unit = V…
1.3.6.1.4.1.20044.21.3.2.18ScalarpmmcMesrline1TxBiasread-onlycurrentLine 1 SFP Laser Bias :This OID gives the bias value of the transceiver Line 1, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <…
1.3.6.1.4.1.20044.21.3.2.19ScalarpmmcMesrline1TxPowerread-onlycurrentLine 1 SFP Tx Power :This OID gives the transmit power value of the transceiver Line 1, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-4…
1.3.6.1.4.1.20044.21.3.2.20ScalarpmmcMesrline1RxPowerread-onlycurrentLine 1 SFP Rx Power :This OID gives the receive power value of the transceiver Line 1, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40…
1.3.6.1.4.1.20044.21.3.3NodepmmcMesrLine
1.3.6.1.4.1.20044.21.3.3.24ScalarpmmcMesrline2Temperatureread-onlycurrentLine 2 SFP Temperature :This OID gives the temperature of the transceiver Line 2, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Uni…
1.3.6.1.4.1.20044.21.3.3.25ScalarpmmcMesrline2Voltread-onlycurrentLine 2 SFP Power Supply :This OID gives the voltage of the transceiver Line 2, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/10000) (Unit = V…
1.3.6.1.4.1.20044.21.3.3.26ScalarpmmcMesrline2TxBiasread-onlycurrentLine 2 SFP Laser Bias :This OID gives the bias value of the transceiver Line 2, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <…
1.3.6.1.4.1.20044.21.3.3.27ScalarpmmcMesrline2TxPowerread-onlycurrentLine 2 SFP Tx Power :This OID gives the transmit power value of the transceiver Line 2, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-4…
1.3.6.1.4.1.20044.21.3.3.28ScalarpmmcMesrline2RxPowerread-onlycurrentLine 2 SFP Rx Power :This OID gives the receive power value of the transceiver Line 2, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40…
1.3.6.1.4.1.20044.21.6NodepmmccontrolsWrite
1.3.6.1.4.1.20044.21.6.1NodepmmcCtrlOther
1.3.6.1.4.1.20044.21.6.1.0NodepmmcCtrlsynth0
1.3.6.1.4.1.20044.21.6.1.0.1ScalarpmmcCtrlConfLoadread-writecurrentLoad Configuration Tables :When set this enables loading from flash configuration1 into the module.
1.3.6.1.4.1.20044.21.6.1.0.9ScalarpmmcCtrlConfFlashread-writecurrentWrite Configuration Tables :This bit saves the current configuration of the module as configuration in the flash. <Help> This control saves the customer config…
1.3.6.1.4.1.20044.21.6.1.0.13ScalarpmmcCtrlConfClearread-writecurrentClear Configuration Tables :This bit clears the configuration tables from configuration in the flash. <Help> This control restores the default configuration of…
1.3.6.1.4.1.20044.21.6.1.4NodepmmcCtrlsynth4
1.3.6.1.4.1.20044.21.6.1.4.1ScalarpmmcCtrlCorrelatOnread-writecurrentEnable Alarm Correlation :This OID enables the alarm correlation in the PM.
1.3.6.1.4.1.20044.21.6.1.4.2ScalarpmmcCtrlCorrelatOffread-writecurrentDisable Alarm Correlation :This OID disables the alarm correlation in the PM.
1.3.6.1.4.1.20044.21.6.1.5NodepmmcCtrlswMgnt
1.3.6.1.4.1.20044.21.6.1.5.2ScalarpmmcCtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the Software. This reset is traffic affecting, and the configuration of Software is reloaded on start…
1.3.6.1.4.1.20044.21.6.1.5.3ScalarpmmcCtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the Software. This reset is not traffic affecting, and the configuration of the Sofwtare remains unch…
1.3.6.1.4.1.20044.21.6.1.64NodepmmcCtrlledTest
1.3.6.1.4.1.20044.21.6.1.64.1ScalarpmmcCtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.21.6.1.64.2ScalarpmmcCtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.21.6.1.64.3ScalarpmmcCtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.21.6.2NodepmmcCtrlClient
1.3.6.1.4.1.20044.21.6.2.16NodepmmcCtrlline1TrscvOnoff
1.3.6.1.4.1.20044.21.6.2.16.1ScalarpmmcCtrlLine1TrscvOnoffread-writecurrentLine 1 SFP Laser Shutdown :This OID switches off the transceiver on Line 1 <Help> This control defines the laser state of the line 1 transceiver
1.3.6.1.4.1.20044.21.6.3NodepmmcCtrlLine
1.3.6.1.4.1.20044.21.6.3.24NodepmmcCtrlline2TrscvOnoff
1.3.6.1.4.1.20044.21.6.3.24.1ScalarpmmcCtrlLine2TrscvOnoffread-writecurrentLine 2 SFP Laser Shutdown :This OID switches off the transceiver on Line 2 <Help> This control defines the laser state of the line 2 transceiver
1.3.6.1.4.1.20044.21.7Nodepmmcri
1.3.6.1.4.1.20044.21.7.2ScalarpmmcRinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.21.7.4ScalarpmmcRinvHwPlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.21.7.5ScalarpmmcRinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.21.7.6ScalarpmmcRinvLine1SFPread-onlycurrentInventory for the SFP: This OID contains the inventory for the Port A SFP
1.3.6.1.4.1.20044.21.7.7ScalarpmmcRinvLine2SFPread-onlycurrentInventory for the SFP: This OID contains the inventory for the Port B SFP
1.3.6.1.4.1.20044.21.9NodepmmcConfig
1.3.6.1.4.1.20044.21.9.1NodepmmcCfgLsd
1.3.6.1.4.1.20044.21.9.1.1NodepmmctableclientLsd
1.3.6.1.4.1.20044.21.9.1.1.2ScalarpmmcCfglsdModeread-writecurrentCAIS mode on Lines Port :This register selects the way to activate the laser upon CAIS/CSF criteria detection on Port
1.3.6.1.4.1.20044.21.9.1.1.3ScalarpmmcCfgline1AccessioCtrbread-writecurrentCAIS contributors on Line 1 Port :This register selects the contributors to upstream CAIS/CSF on Port
1.3.6.1.4.1.20044.21.9.1.1.4ScalarpmmcCfgline1CdrCtrbread-writecurrentCAIS contributors on Line 1 Port :This register selects the contributors to upstream CAIS/CSF on Port
1.3.6.1.4.1.20044.21.9.1.1.5ScalarpmmcCfgline2AccessioCtrbread-writecurrentCAIS contributors on Line 2 Port :This register selects the contributors to downstream CAIS/CSF on Port
1.3.6.1.4.1.20044.21.9.1.1.6ScalarpmmcCfgline2CdrCtrbread-writecurrentCAIS contributors on Line 2 Port :This register selects the contributors to downstream CAIS/CSF on Port
1.3.6.1.4.1.20044.21.9.2NodepmmcCfgStartUp
1.3.6.1.4.1.20044.21.9.2.1NodepmmctableclientStartup
1.3.6.1.4.1.20044.21.9.2.1.2ScalarpmmcCfgline1TrscvCtrlread-writecurrentDefault Settings on Line 1 :This register configures the default initialisation settings on Line 1.
1.3.6.1.4.1.20044.21.9.2.2NodepmmctablelineStartup
1.3.6.1.4.1.20044.21.9.2.2.2ScalarpmmcCfgline2TrscvCtrlread-writecurrentDefault Settings on Line 2 :This register configures the default initialisation settings on Line 2.
1.3.6.1.4.1.20044.21.9.2.2.18ScalarpmmcCfgbitrateSelectread-writecurrentBitrate selection on Line 1/2 :This OID register configure the bitrate for the client and line interface (0=STS48 : 2,4 to 2,7 Gb/s - 1=1GBE : 1,2 to 1,35 Gb/s…
1.3.6.1.4.1.20044.21.9.3NodepmmcCfgLabels
1.3.6.1.4.1.20044.21.9.3.1TablepmmcCfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.21.9.3.1.1RowpmmcCfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.21.9.3.1.1.1ColumnpmmcCfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.21.9.3.1.1.3ColumnpmmcCfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.21.9.3.2TablepmmcCfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.21.9.3.2.1RowpmmcCfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.21.9.3.2.1.1ColumnpmmcCfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.21.9.3.2.1.3ColumnpmmcCfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.21.9.257ScalarpmmcCfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.21.10Nodepmmctraps
1.3.6.1.4.1.20044.21.10.4ScalarpmmctrapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.21.10.30NotificationpmmcLine1TrapNotUrgentGoesOncurrentNot urgent Line 1 default is activated
1.3.6.1.4.1.20044.21.10.31NotificationpmmcLine1TrapNotUrgentGoesOffcurrentNot urgent Line 1 default disappeared
1.3.6.1.4.1.20044.21.10.32NotificationpmmcLine1TrapUrgentGoesOncurrentUrgent Line 1 default is activated
1.3.6.1.4.1.20044.21.10.33NotificationpmmcLine1TrapUrgentGoesOffcurrentUrgent Line 1 default disappeared
1.3.6.1.4.1.20044.21.10.34NotificationpmmcLine1TrapCritGoesOncurrentCritical Line 1 default is activated
1.3.6.1.4.1.20044.21.10.35NotificationpmmcLine1TrapCritGoesOffcurrentCritical Line 1 default disappeared
1.3.6.1.4.1.20044.21.10.40NotificationpmmcLine2NotUrgentGoesOncurrentNot urgent Line 2 default is activated
1.3.6.1.4.1.20044.21.10.41NotificationpmmcLine2NotUrgentGoesOffcurrentNot urgent Line 2 default disappeared
1.3.6.1.4.1.20044.21.10.42NotificationpmmcLine2UrgentGoesOncurrentUrgent Line 2 default is activated
1.3.6.1.4.1.20044.21.10.43NotificationpmmcLine2UrgentGoesOffcurrentUrgent Line 2 default disappeared
1.3.6.1.4.1.20044.21.10.44NotificationpmmcLine2CritGoesOncurrentCritical Line 2 default is activated
1.3.6.1.4.1.20044.21.10.45NotificationpmmcLine2CritGoesOffcurrentCritical Line 2 default disappeared
1.3.6.1.4.1.20044.21.10.50NotificationpmmcPowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.21.10.51NotificationpmmcPowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared
Type Definitions
NameSyntaxStatusDescription
PmmcBitRateINTEGER { rateSTM16OC48(0), rate1GBE(1), rateSTM4OC12(2), rateSTM1OC3(3), rate2GFC(4), rate1GFC(5), rateFastEthernet(7), rateSTM16FEC(8), rateSTM4FEC(9), rateSTM1FEC(10) }currentdifferent rates for a client and line ports