EKINOPS-PmOSC-MIB
161 objects
MIB for the Ekinops PmOsc hardware.
Imported Objects
| EKINOPS-MIB | EkiApiState EkiMeasureType EkiMode ekinops EkiOnOff EkiProtocol EkiState EkiSynchroMode |
| SNMPv2-SMI | Counter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20044.14 | IdentitymodulePmOSC | MIB for the Ekinops PmOsc hardware. | ||
| 1.3.6.1.4.1.20044.14.2 | Nodepmoscalarms | |||
| 1.3.6.1.4.1.20044.14.2.1 | NodepmoscAlmOther | |||
| 1.3.6.1.4.1.20044.14.2.1.1 | NodepmoscAlmOtherNurg | |||
| 1.3.6.1.4.1.20044.14.2.1.2 | NodepmoscAlmOtherUrg | |||
| 1.3.6.1.4.1.20044.14.2.1.3 | NodepmoscAlmOtherCrit | |||
| 1.3.6.1.4.1.20044.14.2.1.3.0 | NodepmoscAlmsynthAlm0 | |||
| 1.3.6.1.4.1.20044.14.2.1.3.0.9 | ScalarpmoscAlmModuleGlobFailure | read-only | current | Module Failure :This OID is set on detection of a failure originating from the PM <Condtype> MODULE_GLOB_FAILURE <Probcause> equipmentMalfunction (16) <Alarmty… |
| 1.3.6.1.4.1.20044.14.2.1.3.0.15 | ScalarpmoscAlmDefFuseA | read-only | current | Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.14.2.1.3.0.16 | ScalarpmoscAlmDefFuseB | read-only | current | Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.14.2.2 | NodepmoscAlmClient | |||
| 1.3.6.1.4.1.20044.14.2.2.1 | NodepmoscAlmClientNurg | |||
| 1.3.6.1.4.1.20044.14.2.2.1.20 | NodepmoscAlmportaSfpWarnDdm | |||
| 1.3.6.1.4.1.20044.14.2.2.1.20.1 | ScalarpmoscAlmPortaTxPwLowWng | read-only | current | SFP A Tx Power Low Warning :Warning indicating that the SFP output power of port A is lower than the threshold value written in the SFP EEPROM <Condtype> PORTA… |
| 1.3.6.1.4.1.20044.14.2.2.1.20.2 | ScalarpmoscAlmPortaTxPwrHighWng | read-only | current | SFP A Tx Power High Warning :Warning indicating that the SFP output power of port A is higher than the threshold value written in the SFP EEPROM <Condtype> POR… |
| 1.3.6.1.4.1.20044.14.2.2.1.20.3 | ScalarpmoscAlmPortaTxBiasLowWng | read-only | current | SFP A Bias Low Warning :Warning indicating that the SFP laser bias current of port A is lower than the threshold value written in the SFP EEPROM <Condtype> POR… |
| 1.3.6.1.4.1.20044.14.2.2.1.20.4 | ScalarpmoscAlmPortaTxBiasHighWng | read-only | current | SFP A Bias High Warning :Warning indicating that the SFP laser bias current of port A is higher than the threshold value written in the SFP EEPROM <Condtype> P… |
| 1.3.6.1.4.1.20044.14.2.2.1.20.7 | ScalarpmoscAlmPortaTempLowWng | read-only | current | SFP A Temp Low Warning :Warning indicating that the SFP temperature of port A is lower than the threshold value written in the SFP EEPROM <Condtype> PORTA_TEMP… |
| 1.3.6.1.4.1.20044.14.2.2.1.20.8 | ScalarpmoscAlmPortaTempHighWng | read-only | current | SFP A Temp High Warning :Warning indicating that the SFP temperature of port A is higher than the threshold value written in the SFP EEPROM <Condtype> PORTA_TE… |
| 1.3.6.1.4.1.20044.14.2.2.1.20.15 | ScalarpmoscAlmPortaRxPwrLowWng | read-only | current | SFP A Rx Power Low Warning :Warning indicating that the SFP input power of port A is lower than the threshold value written in the SFP EEPROM <Condtype> PORTA_… |
| 1.3.6.1.4.1.20044.14.2.2.1.20.16 | ScalarpmoscAlmPortaRxPwrHighWng | read-only | current | SFP A Rx Power High Warning :Warning indicating that the SFP input power of port A is higher than the threshold value written in the SFP EEPROM <Condtype> PORT… |
| 1.3.6.1.4.1.20044.14.2.2.2 | NodepmoscAlmClientUrg | |||
| 1.3.6.1.4.1.20044.14.2.2.2.18 | NodepmoscAlmportaSfpAlmDdm | |||
| 1.3.6.1.4.1.20044.14.2.2.2.18.1 | ScalarpmoscAlmPortaTxPwrLowAla | read-only | current | SFP A Tx Power Low :Alarm indicating that the SFP output power of port A is lower than the threshold value written in the SFP EEPROM <Condtype> PORTA_TX_PWR_LO… |
| 1.3.6.1.4.1.20044.14.2.2.2.18.2 | ScalarpmoscAlmPortaTxPwrHighAla | read-only | current | SFP A Tx Power High :Alarm indicating that the SFP output power of port A is higher than the threshold value written in the SFP EEPROM <Condtype> PORTA_TX_PWR_… |
| 1.3.6.1.4.1.20044.14.2.2.2.18.3 | ScalarpmoscAlmPortaTxBiasLowAla | read-only | current | SFP A Bias Low :Alarm indicating that the SFP laser bias current of port A is lower than the threshold value written in the SFP EEPROM <Condtype> PORTA_TX_BIAS… |
| 1.3.6.1.4.1.20044.14.2.2.2.18.4 | ScalarpmoscAlmPortaTxBiasHighAla | read-only | current | SFP A Bias High :Alarm indicating that the SFP laser bias current of port A is higher than the threshold value written in the SFP EEPROM <Condtype> PORTA_TX_BI… |
| 1.3.6.1.4.1.20044.14.2.2.2.18.7 | ScalarpmoscAlmPortaTempLowAla | read-only | current | SFP A Temp Low :Alarm indicating that the SFP temperature of port A is lower than the threshold value written in the SFP EEPROM <Condtype> PORTA_TEMP_LOW_ALA <… |
| 1.3.6.1.4.1.20044.14.2.2.2.18.8 | ScalarpmoscAlmPortaTempHighAla | read-only | current | SFP A Temp High :Alarm indicating that the SFP temperature of port A is higher than the threshold value written in the SFP EEPROM <Condtype> PORTA_TEMP_HIGH_AL… |
| 1.3.6.1.4.1.20044.14.2.2.2.18.15 | ScalarpmoscAlmPortaRxPwrLowAla | read-only | current | SFP A Rx Power Low :Alarm indicating that the SFP input power of port A is lower than the threshold value written in the SFP EEPROM <Condtype> PORTA_RX_PWR_LOW… |
| 1.3.6.1.4.1.20044.14.2.2.2.18.16 | ScalarpmoscAlmPortaRxPwrHighAla | read-only | current | SFP A Rx Power High :Alarm indicating that the SFP input power of port A is higher than the threshold value written in the SFP EEPROM <Condtype> PORTA_RX_PWR_H… |
| 1.3.6.1.4.1.20044.14.2.2.3 | NodepmoscAlmClientCrit | |||
| 1.3.6.1.4.1.20044.14.2.2.3.8 | NodepmoscAlmsynthAlm8 | |||
| 1.3.6.1.4.1.20044.14.2.2.3.8.1 | ScalarpmoscAlmPortaSfpAbsent | read-only | current | SFP A Absent :This OID indicates that the SFP module A is not present. <Help> This alarm indicates if the port A transceiver is present. <Condtype> PORTA_SFP_A… |
| 1.3.6.1.4.1.20044.14.2.2.3.8.2 | ScalarpmoscAlmPortaDdmAbsent | read-only | current | DDM Supported On SFP A :This OID indicates that the SFP module A does not support Digital Diagnostic Monitoring Functions <Help> This status indicates if the p… |
| 1.3.6.1.4.1.20044.14.2.2.3.8.4 | ScalarpmoscAlmPortaHwFail | read-only | current | Port A HW Failure :This OID indicates a hardware failure on the port A <Condtype> PORTA_HW_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlar… |
| 1.3.6.1.4.1.20044.14.2.2.3.8.5 | ScalarpmoscAlmPortaLsd | read-only | current | SFP A Laser Shutdown :This OID indicates the optical output power is off on port A <Help> This status indicates if the port A transceiver laser is ON or OFF <C… |
| 1.3.6.1.4.1.20044.14.2.2.3.8.6 | ScalarpmoscAlmPortaLocalOos | read-only | current | SFP A In Service :This OID indicates that the Port A is In Service (1) of Out or Service (2) <Help> This status indicates if the port A is in service <Condtype… |
| 1.3.6.1.4.1.20044.14.2.2.3.8.9 | ScalarpmoscAlmPortaDdmWarning | read-only | current | Warning DDM On SFP A :This OID indicates a warning is present coming out of optical interface DDM on port A <Help> This alarm indicates if a DDM Warning has be… |
| 1.3.6.1.4.1.20044.14.2.2.3.8.10 | ScalarpmoscAlmPortaDdmAlm | read-only | current | Alarm DDM On SFP A :This OID indicates an alarm is present coming out of optical interface DDM on port A <Help> This alarm indicates if a DDM Alarm has been de… |
| 1.3.6.1.4.1.20044.14.2.2.3.8.12 | ScalarpmoscAlmPortaFail | read-only | current | Port A Failure :This OID indicates a failure on the port A <Condtype> PORTA_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12) <Polarit… |
| 1.3.6.1.4.1.20044.14.2.2.3.16 | NodepmoscAlmportaAccessioAlm | |||
| 1.3.6.1.4.1.20044.14.2.2.3.16.1 | ScalarpmoscAlmPortaLasFail | read-only | current | SFP A Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the port A (this alarm reports the transmitter failure alarm generated … |
| 1.3.6.1.4.1.20044.14.2.2.3.16.4 | ScalarpmoscAlmPortaLos | read-only | current | Loss Of Optical Signal On SFP A :This OID indicates that no signal is present on the SFP A <Help> This alarm indicates if an optical signal is detected on the … |
| 1.3.6.1.4.1.20044.14.2.3 | NodepmoscAlmLine | |||
| 1.3.6.1.4.1.20044.14.2.3.1 | NodepmoscAlmLineNurg | |||
| 1.3.6.1.4.1.20044.14.2.3.1.28 | NodepmoscAlmportbSfpWarnDdm | |||
| 1.3.6.1.4.1.20044.14.2.3.1.28.1 | ScalarpmoscAlmPortbTxPwLowWng | read-only | current | SFP B Tx Power Low Warning :Warning indicating that the SFP output power of port B is lower than the threshold value written in the SFP EEPROM <Condtype> PORTB… |
| 1.3.6.1.4.1.20044.14.2.3.1.28.2 | ScalarpmoscAlmPortbTxPwrHighWng | read-only | current | SFP B Tx Power High Warning :Warning indicating that the SFP output power of port B is higher than the threshold value written in the SFP EEPROM <Condtype> POR… |
| 1.3.6.1.4.1.20044.14.2.3.1.28.3 | ScalarpmoscAlmPortbTxBiasLowWng | read-only | current | SFP B Bias Low Warning :Warning indicating that the SFP laser bias current of port B is lower than the threshold value written in the SFP EEPROM <Condtype> POR… |
| 1.3.6.1.4.1.20044.14.2.3.1.28.4 | ScalarpmoscAlmPortbTxBiasHighWng | read-only | current | SFP B Bias High Warning :Warning indicating that the SFP laser bias current of port B is higher than the threshold value written in the SFP EEPROM <Condtype> P… |
| 1.3.6.1.4.1.20044.14.2.3.1.28.7 | ScalarpmoscAlmPortbTempLowWng | read-only | current | SFP B Temp Low Warning :Warning indicating that the SFP temperature of port B is lower than the threshold value written in the SFP EEPROM <Condtype> PORTB_TEMP… |
| 1.3.6.1.4.1.20044.14.2.3.1.28.8 | ScalarpmoscAlmPortbTempHighWng | read-only | current | SFP B Temp High Warning :Warning indicating that the SFP temperature of port B is higher than the threshold value written in the SFP EEPROM <Condtype> PORTB_TE… |
| 1.3.6.1.4.1.20044.14.2.3.1.28.15 | ScalarpmoscAlmPortbRxPwrLowWng | read-only | current | SFP B Rx Power Low Warning :Warning indicating that the SFP input power of port B is lower than the threshold value written in the SFP EEPROM <Condtype> PORTB_… |
| 1.3.6.1.4.1.20044.14.2.3.1.28.16 | ScalarpmoscAlmPortbRxPwrHighWng | read-only | current | SFP B Rx Power High Warning :Warning indicating that the SFP input power of port B is higher than the threshold value written in the SFP EEPROM <Condtype> PORT… |
| 1.3.6.1.4.1.20044.14.2.3.2 | NodepmoscAlmLineUrg | |||
| 1.3.6.1.4.1.20044.14.2.3.2.26 | NodepmoscAlmportbSfpAlmDdm | |||
| 1.3.6.1.4.1.20044.14.2.3.2.26.1 | ScalarpmoscAlmPortbTxPwrLowAla | read-only | current | SFP B Tx Power Low :Alarm indicating that the SFP output power of port B is lower than the threshold value written in the SFP EEPROM <Condtype> PORTB_TX_PWR_LO… |
| 1.3.6.1.4.1.20044.14.2.3.2.26.2 | ScalarpmoscAlmPortbTxPwrHighAla | read-only | current | SFP B Tx Power High :Alarm indicating that the SFP output power of port B is higher than the threshold value written in the SFP EEPROM <Condtype> PORTB_TX_PWR_… |
| 1.3.6.1.4.1.20044.14.2.3.2.26.3 | ScalarpmoscAlmPortbTxBiasLowAla | read-only | current | SFP B Bias Low :Alarm indicating that the SFP laser bias current of port B is lower than the threshold value written in the SFP EEPROM <Condtype> PORTB_TX_BIAS… |
| 1.3.6.1.4.1.20044.14.2.3.2.26.4 | ScalarpmoscAlmPortbTxBiasHighAla | read-only | current | SFP B Bias High :Alarm indicating that the SFP laser bias current of port B is higher than the threshold value written in the SFP EEPROM <Condtype> PORTB_TX_BI… |
| 1.3.6.1.4.1.20044.14.2.3.2.26.7 | ScalarpmoscAlmPortbTempLowAla | read-only | current | SFP B Temp Low :Alarm indicating that the SFP temperature of port B is lower than the threshold value written in the SFP EEPROM <Condtype> PORTB_TEMP_LOW_ALA <… |
| 1.3.6.1.4.1.20044.14.2.3.2.26.8 | ScalarpmoscAlmPortbTempHighAla | read-only | current | SFP B Temp High :Alarm indicating that the SFP temperature of port B is higher than the threshold value written in the SFP EEPROM <Condtype> PORTB_TEMP_HIGH_AL… |
| 1.3.6.1.4.1.20044.14.2.3.2.26.15 | ScalarpmoscAlmPortbRxPwrLowAla | read-only | current | SFP B Rx Power Low :Alarm indicating that the SFP input power of port B is lower than the threshold value written in the SFP EEPROM <Condtype> PORTB_RX_PWR_LOW… |
| 1.3.6.1.4.1.20044.14.2.3.2.26.16 | ScalarpmoscAlmPortbRxPwrHighAla | read-only | current | SFP B Rx Power High :Alarm indicating that the SFP input power of port B is higher than the threshold value written in the SFP EEPROM <Condtype> PORTB_RX_PWR_H… |
| 1.3.6.1.4.1.20044.14.2.3.3 | NodepmoscAlmLineCrit | |||
| 1.3.6.1.4.1.20044.14.2.3.3.7 | NodepmoscAlmsynthAlm7 | |||
| 1.3.6.1.4.1.20044.14.2.3.3.7.1 | ScalarpmoscAlmPortbSfpAbsent | read-only | current | SFP B Absent :This OID indicates that the SFP module B is not present. <Help> This alarm indicates if the port B transceiver is present. <Condtype> PORTB_SFP_A… |
| 1.3.6.1.4.1.20044.14.2.3.3.7.2 | ScalarpmoscAlmPortbDdmAbsent | read-only | current | DDM Supported On SFP B :This OID indicates that the SFP module B does not support Digital Diagnostic Monitoring Functions <Help> This status indicates if the p… |
| 1.3.6.1.4.1.20044.14.2.3.3.7.4 | ScalarpmoscAlmPortbHwFail | read-only | current | Port B HW Failure :This OID indicates a hardware failure on the port B <Condtype> PORTB_HW_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlar… |
| 1.3.6.1.4.1.20044.14.2.3.3.7.5 | ScalarpmoscAlmPortbLsd | read-only | current | SFP B Laser Shutdown :This OID indicates the optical output power is off on port B <Help> This status indicates if the port B transceiver laser is ON or OFF <C… |
| 1.3.6.1.4.1.20044.14.2.3.3.7.6 | ScalarpmoscAlmPortbLocalOos | read-only | current | SFP B In Service :This OID indicates that the Port B is In Service (1) of Out or Service (2) <Help> This status indicates if the port B is in service <Condtype… |
| 1.3.6.1.4.1.20044.14.2.3.3.7.9 | ScalarpmoscAlmPortbDdmWarning | read-only | current | Warning DDM On SFP B :This OID indicates a warning is present coming out of optical interface DDM on port B <Help> This alarm indicates if a DDM Warning has be… |
| 1.3.6.1.4.1.20044.14.2.3.3.7.10 | ScalarpmoscAlmPortbDdmAlm | read-only | current | Alarm DDM On SFP B :This OID indicates an alarm is present coming out of optical interface DDM on port B <Help> This alarm indicates if a DDM Alarm has been de… |
| 1.3.6.1.4.1.20044.14.2.3.3.7.12 | ScalarpmoscAlmPortbFail | read-only | current | Port B Failure :This OID indicates a failure on the port B <Condtype> PORTB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12) <Polarit… |
| 1.3.6.1.4.1.20044.14.2.3.3.24 | NodepmoscAlmportbAccessioAlm | |||
| 1.3.6.1.4.1.20044.14.2.3.3.24.1 | ScalarpmoscAlmPortbLasFail | read-only | current | SFP B Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the port A (this alarm reports the transmitter failure alarm generated … |
| 1.3.6.1.4.1.20044.14.2.3.3.24.4 | ScalarpmoscAlmPortbLos | read-only | current | Loss Of Optical Signal On SFP B :This OID indicates that no signal is present on the SFP B <Help> This alarm indicates if an optical signal is detected on the … |
| 1.3.6.1.4.1.20044.14.3 | Nodepmoscmeasures | |||
| 1.3.6.1.4.1.20044.14.3.1 | NodepmoscMesrOther | |||
| 1.3.6.1.4.1.20044.14.3.2 | NodepmoscMesrClient | |||
| 1.3.6.1.4.1.20044.14.3.2.16 | ScalarpmoscMesrportaTemperature | read-only | current | SFP A Temperature :This OID gives the temperature of the SFP A, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit = C) <Help> This… |
| 1.3.6.1.4.1.20044.14.3.2.17 | ScalarpmoscMesrportaVolt | read-only | current | SFP A Power Supply :This OID gives the voltage of the SFP A, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/10000) (Unit = V) <Help> This meas… |
| 1.3.6.1.4.1.20044.14.3.2.18 | ScalarpmoscMesrportaTxBias | read-only | current | SFP A Laser Bias :This OID gives the bias value of the SFP A, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <Help> This measure… |
| 1.3.6.1.4.1.20044.14.3.2.19 | ScalarpmoscMesrportaTxPower | read-only | current | SFP A Tx Power :This OID gives the transmit power value of the SFP A, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <H… |
| 1.3.6.1.4.1.20044.14.3.2.20 | ScalarpmoscMesrportaRxPower | read-only | current | SFP A Rx Power :This OID gives the receive power value of the SFP A, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <He… |
| 1.3.6.1.4.1.20044.14.3.3 | NodepmoscMesrLine | |||
| 1.3.6.1.4.1.20044.14.3.3.24 | ScalarpmoscMesrportbTemperature | read-only | current | SFP B Temperature :This OID gives the temperature of the SFP B, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit = C) <Help> This… |
| 1.3.6.1.4.1.20044.14.3.3.25 | ScalarpmoscMesrportbVolt | read-only | current | SFP B Power Supply :This OID gives the voltage of the SFP B, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/10000) (Unit = V) <Help> This meas… |
| 1.3.6.1.4.1.20044.14.3.3.26 | ScalarpmoscMesrportbTxBias | read-only | current | SFP B Laser Bias :This OID gives the bias value of the SFP B, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <Help> This measure… |
| 1.3.6.1.4.1.20044.14.3.3.27 | ScalarpmoscMesrportbTxPower | read-only | current | SFP B Tx Power :This OID gives the transmit power value of the SFP B, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <H… |
| 1.3.6.1.4.1.20044.14.3.3.28 | ScalarpmoscMesrportbRxPower | read-only | current | SFP B Rx Power :This OID gives the receive power value of the SFP B, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <He… |
| 1.3.6.1.4.1.20044.14.6 | NodepmosccontrolsWrite | |||
| 1.3.6.1.4.1.20044.14.6.1 | NodepmoscCtrlOther | |||
| 1.3.6.1.4.1.20044.14.6.1.0 | NodepmoscCtrlsynth0 | |||
| 1.3.6.1.4.1.20044.14.6.1.0.1 | ScalarpmoscCtrlConfLoad | read-write | current | Load Configuration Tables :When set this enables loading from flash configuration1 into the module. |
| 1.3.6.1.4.1.20044.14.6.1.0.9 | ScalarpmoscCtrlConfFlash | read-write | current | Write Configuration Tables :This bit saves the current configuration of the module as configuration in the flash. <Help> This control saves the customer config… |
| 1.3.6.1.4.1.20044.14.6.1.0.13 | ScalarpmoscCtrlConfClear | read-write | current | Clear Configuration Tables :This bit clears the configuration tables from configuration in the flash. <Help> This control restores the default configuration of… |
| 1.3.6.1.4.1.20044.14.6.1.4 | NodepmoscCtrlsynth4 | |||
| 1.3.6.1.4.1.20044.14.6.1.4.1 | ScalarpmoscCtrlCorrelatOn | read-write | current | Enable Alarm Correlation :This OID enables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.14.6.1.4.2 | ScalarpmoscCtrlCorrelatOff | read-write | current | Disable Alarm Correlation :This OID disables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.14.6.1.5 | NodepmoscCtrlswMgnt | |||
| 1.3.6.1.4.1.20044.14.6.1.5.2 | ScalarpmoscCtrlColdReset | read-write | current | Software Cold Reset :This OID, when set, causes a cold reset of the Software. This reset is traffic affecting, and the configuration of Software is reloaded on… |
| 1.3.6.1.4.1.20044.14.6.1.5.3 | ScalarpmoscCtrlWarmReset | read-write | current | Software Warm Reset :This OID, when set, causes a warm reset of the Software. This reset is not traffic affecting, and the configuration of the Sofwtare remain… |
| 1.3.6.1.4.1.20044.14.6.1.64 | NodepmoscCtrlledTest | |||
| 1.3.6.1.4.1.20044.14.6.1.64.1 | ScalarpmoscCtrlGreenLed | read-write | current | Green Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green |
| 1.3.6.1.4.1.20044.14.6.1.64.2 | ScalarpmoscCtrlRedLed | read-write | current | Red Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red |
| 1.3.6.1.4.1.20044.14.6.1.64.3 | ScalarpmoscCtrlLedOff | read-write | current | Leds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF |
| 1.3.6.1.4.1.20044.14.6.1.65 | NodepmoscCtrlmoduleOosMode | |||
| 1.3.6.1.4.1.20044.14.6.1.65.1 | ScalarpmoscCtrlModuleOosMode | read-write | current | PM Out Of Service :This OID sets the PM Out Of Service <Help> This control defines the service state of the complete module |
| 1.3.6.1.4.1.20044.14.6.2 | NodepmoscCtrlClient | |||
| 1.3.6.1.4.1.20044.14.6.2.16 | NodepmoscCtrlportaSfpOnoff | |||
| 1.3.6.1.4.1.20044.14.6.2.16.1 | ScalarpmoscCtrlPortaSfpOnoff | read-write | current | SFP A Optical Laser Shutdown :This OID switches off the SFP A <Help> This control defines the laser state of the port A transceiver |
| 1.3.6.1.4.1.20044.14.6.2.17 | NodepmoscCtrlportaOosMode | |||
| 1.3.6.1.4.1.20044.14.6.2.17.1 | ScalarpmoscCtrlPortaOosMode | read-write | current | SFP A Port Out Of Service :This OID sets the Port A Out Of Service <Help> This controls defines the service state of the port A |
| 1.3.6.1.4.1.20044.14.6.3 | NodepmoscCtrlLine | |||
| 1.3.6.1.4.1.20044.14.6.3.24 | NodepmoscCtrlportbSfpOnoff | |||
| 1.3.6.1.4.1.20044.14.6.3.24.1 | ScalarpmoscCtrlPortbSfpOnoff | read-write | current | SFP B Optical Laser Shutdown :This OID switches off the SFP B <Help> This control defines the laser state of the port B transceiver |
| 1.3.6.1.4.1.20044.14.6.3.25 | NodepmoscCtrlportbOosMode | |||
| 1.3.6.1.4.1.20044.14.6.3.25.1 | ScalarpmoscCtrlPortbOosMode | read-write | current | SFP B Port Out Of Service :This OID sets the Port B Out Of Service <Help> This controls defines the service state of the port B |
| 1.3.6.1.4.1.20044.14.7 | Nodepmoscri | |||
| 1.3.6.1.4.1.20044.14.7.2 | ScalarpmoscRinvReloadInventory | read-write | current | Reload the inventory: This OID triggers an inventory reload. |
| 1.3.6.1.4.1.20044.14.7.4 | ScalarpmoscRinvHwPlatform | read-only | current | Module platform description: This OID contains the description of the Module. |
| 1.3.6.1.4.1.20044.14.7.5 | ScalarpmoscRinvSwPlatform | read-only | current | SW platform description: This OID contains the description of the Software platform. |
| 1.3.6.1.4.1.20044.14.7.6 | ScalarpmoscRinvPortASFP | read-only | current | Inventory for the SFP: This OID contains the inventory for the Port A SFP |
| 1.3.6.1.4.1.20044.14.7.7 | ScalarpmoscRinvPortBSFP | read-only | current | Inventory for the SFP: This OID contains the inventory for the Port B SFP |
| 1.3.6.1.4.1.20044.14.9 | NodepmoscConfig | |||
| 1.3.6.1.4.1.20044.14.9.1 | NodepmoscCfgLsd | |||
| 1.3.6.1.4.1.20044.14.9.2 | NodepmoscCfgStartUp | |||
| 1.3.6.1.4.1.20044.14.9.2.1 | NodepmosctableclientStartup | |||
| 1.3.6.1.4.1.20044.14.9.2.1.2 | ScalarpmoscCfgportaSfpCtrl | read-write | current | Default Settings on Port A :This register configures the default initialisation settings on port A. |
| 1.3.6.1.4.1.20044.14.9.2.1.3 | ScalarpmoscCfgportaOosMode | read-write | current | Default Settings on Port A :This register configures the default initialisation settings on port A. |
| 1.3.6.1.4.1.20044.14.9.2.2 | NodepmosctablelineStartup | |||
| 1.3.6.1.4.1.20044.14.9.2.2.2 | ScalarpmoscCfgportbSfpCtrl | read-write | current | Default Settings on Port B :This register configures the default initialisation settings on port B. |
| 1.3.6.1.4.1.20044.14.9.2.2.3 | ScalarpmoscCfgportbOosMode | read-write | current | Default Settings on Port B :This register configures the default initialisation settings on port B. |
| 1.3.6.1.4.1.20044.14.9.3 | NodepmoscCfgLabels | |||
| 1.3.6.1.4.1.20044.14.9.3.1 | TablepmoscCfgLabelclientTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.14.9.3.1.1 | RowpmoscCfgLabelclientEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.14.9.3.1.1.1 | ColumnpmoscCfgLabelclientIndex | read-only | current | Index definition for the labelclient table |
| 1.3.6.1.4.1.20044.14.9.3.1.1.3 | ColumnpmoscCfgLabelclientPortn | read-write | current | Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. |
| 1.3.6.1.4.1.20044.14.9.3.2 | TablepmoscCfgLabellineTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.14.9.3.2.1 | RowpmoscCfgLabellineEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.14.9.3.2.1.1 | ColumnpmoscCfgLabellineIndex | read-only | current | Index definition for the labelline table |
| 1.3.6.1.4.1.20044.14.9.3.2.1.3 | ColumnpmoscCfgLabellinePortn | read-write | current | Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. |
| 1.3.6.1.4.1.20044.14.9.257 | ScalarpmoscCfgWriteConfiguration | read-write | current | Write configuration to module:This OID writes the complete configuration to the module |
| 1.3.6.1.4.1.20044.14.10 | Nodepmosctraps | |||
| 1.3.6.1.4.1.20044.14.10.4 | ScalarpmosctrapBoardNumber | read-only | current | Last module which generates a trap |
| 1.3.6.1.4.1.20044.14.10.30 | NotificationpmoscPortaTrapNotUrgentGoesOn | current | Not urgent Port A default is activated | |
| 1.3.6.1.4.1.20044.14.10.31 | NotificationpmoscPortaTrapNotUrgentGoesOff | current | Not urgent Port A default disappeared | |
| 1.3.6.1.4.1.20044.14.10.32 | NotificationpmoscPortaTrapUrgentGoesOn | current | Urgent Port A default is activated | |
| 1.3.6.1.4.1.20044.14.10.33 | NotificationpmoscPortaTrapUrgentGoesOff | current | Urgent Port A default disappeared | |
| 1.3.6.1.4.1.20044.14.10.34 | NotificationpmoscPortaTrapCritGoesOn | current | Critical Port A default is activated | |
| 1.3.6.1.4.1.20044.14.10.35 | NotificationpmoscPortaTrapCritGoesOff | current | Critical Port A default disappeared | |
| 1.3.6.1.4.1.20044.14.10.40 | NotificationpmoscPortbNotUrgentGoesOn | current | Not urgent Port B default is activated | |
| 1.3.6.1.4.1.20044.14.10.41 | NotificationpmoscPortbNotUrgentGoesOff | current | Not urgent Port B default disappeared | |
| 1.3.6.1.4.1.20044.14.10.42 | NotificationpmoscPortbUrgentGoesOn | current | Urgent Port B default is activated | |
| 1.3.6.1.4.1.20044.14.10.43 | NotificationpmoscPortbUrgentGoesOff | current | Urgent Port B default disappeared | |
| 1.3.6.1.4.1.20044.14.10.44 | NotificationpmoscPortbCritGoesOn | current | Critical Port B default is activated | |
| 1.3.6.1.4.1.20044.14.10.45 | NotificationpmoscPortbCritGoesOff | current | Critical Port B default disappeared | |
| 1.3.6.1.4.1.20044.14.10.50 | NotificationpmoscPowerTrapUrgentGoesOn | current | Urgent power supply default is activated | |
| 1.3.6.1.4.1.20044.14.10.51 | NotificationpmoscPowerTrapUrgentGoesOff | current | Urgent power supply default disappeared |