EKINOPS-PmOSC-MIB

161 objects
MIB for the Ekinops PmOsc hardware.
OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.14IdentitymodulePmOSCMIB for the Ekinops PmOsc hardware.
1.3.6.1.4.1.20044.14.2Nodepmoscalarms
1.3.6.1.4.1.20044.14.2.1NodepmoscAlmOther
1.3.6.1.4.1.20044.14.2.1.1NodepmoscAlmOtherNurg
1.3.6.1.4.1.20044.14.2.1.2NodepmoscAlmOtherUrg
1.3.6.1.4.1.20044.14.2.1.3NodepmoscAlmOtherCrit
1.3.6.1.4.1.20044.14.2.1.3.0NodepmoscAlmsynthAlm0
1.3.6.1.4.1.20044.14.2.1.3.0.9ScalarpmoscAlmModuleGlobFailureread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the PM <Condtype> MODULE_GLOB_FAILURE <Probcause> equipmentMalfunction (16) <Alarmty…
1.3.6.1.4.1.20044.14.2.1.3.0.15ScalarpmoscAlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.14.2.1.3.0.16ScalarpmoscAlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.14.2.2NodepmoscAlmClient
1.3.6.1.4.1.20044.14.2.2.1NodepmoscAlmClientNurg
1.3.6.1.4.1.20044.14.2.2.1.20NodepmoscAlmportaSfpWarnDdm
1.3.6.1.4.1.20044.14.2.2.1.20.1ScalarpmoscAlmPortaTxPwLowWngread-onlycurrentSFP A Tx Power Low Warning :Warning indicating that the SFP output power of port A is lower than the threshold value written in the SFP EEPROM <Condtype> PORTA…
1.3.6.1.4.1.20044.14.2.2.1.20.2ScalarpmoscAlmPortaTxPwrHighWngread-onlycurrentSFP A Tx Power High Warning :Warning indicating that the SFP output power of port A is higher than the threshold value written in the SFP EEPROM <Condtype> POR…
1.3.6.1.4.1.20044.14.2.2.1.20.3ScalarpmoscAlmPortaTxBiasLowWngread-onlycurrentSFP A Bias Low Warning :Warning indicating that the SFP laser bias current of port A is lower than the threshold value written in the SFP EEPROM <Condtype> POR…
1.3.6.1.4.1.20044.14.2.2.1.20.4ScalarpmoscAlmPortaTxBiasHighWngread-onlycurrentSFP A Bias High Warning :Warning indicating that the SFP laser bias current of port A is higher than the threshold value written in the SFP EEPROM <Condtype> P…
1.3.6.1.4.1.20044.14.2.2.1.20.7ScalarpmoscAlmPortaTempLowWngread-onlycurrentSFP A Temp Low Warning :Warning indicating that the SFP temperature of port A is lower than the threshold value written in the SFP EEPROM <Condtype> PORTA_TEMP…
1.3.6.1.4.1.20044.14.2.2.1.20.8ScalarpmoscAlmPortaTempHighWngread-onlycurrentSFP A Temp High Warning :Warning indicating that the SFP temperature of port A is higher than the threshold value written in the SFP EEPROM <Condtype> PORTA_TE…
1.3.6.1.4.1.20044.14.2.2.1.20.15ScalarpmoscAlmPortaRxPwrLowWngread-onlycurrentSFP A Rx Power Low Warning :Warning indicating that the SFP input power of port A is lower than the threshold value written in the SFP EEPROM <Condtype> PORTA_…
1.3.6.1.4.1.20044.14.2.2.1.20.16ScalarpmoscAlmPortaRxPwrHighWngread-onlycurrentSFP A Rx Power High Warning :Warning indicating that the SFP input power of port A is higher than the threshold value written in the SFP EEPROM <Condtype> PORT…
1.3.6.1.4.1.20044.14.2.2.2NodepmoscAlmClientUrg
1.3.6.1.4.1.20044.14.2.2.2.18NodepmoscAlmportaSfpAlmDdm
1.3.6.1.4.1.20044.14.2.2.2.18.1ScalarpmoscAlmPortaTxPwrLowAlaread-onlycurrentSFP A Tx Power Low :Alarm indicating that the SFP output power of port A is lower than the threshold value written in the SFP EEPROM <Condtype> PORTA_TX_PWR_LO…
1.3.6.1.4.1.20044.14.2.2.2.18.2ScalarpmoscAlmPortaTxPwrHighAlaread-onlycurrentSFP A Tx Power High :Alarm indicating that the SFP output power of port A is higher than the threshold value written in the SFP EEPROM <Condtype> PORTA_TX_PWR_…
1.3.6.1.4.1.20044.14.2.2.2.18.3ScalarpmoscAlmPortaTxBiasLowAlaread-onlycurrentSFP A Bias Low :Alarm indicating that the SFP laser bias current of port A is lower than the threshold value written in the SFP EEPROM <Condtype> PORTA_TX_BIAS…
1.3.6.1.4.1.20044.14.2.2.2.18.4ScalarpmoscAlmPortaTxBiasHighAlaread-onlycurrentSFP A Bias High :Alarm indicating that the SFP laser bias current of port A is higher than the threshold value written in the SFP EEPROM <Condtype> PORTA_TX_BI…
1.3.6.1.4.1.20044.14.2.2.2.18.7ScalarpmoscAlmPortaTempLowAlaread-onlycurrentSFP A Temp Low :Alarm indicating that the SFP temperature of port A is lower than the threshold value written in the SFP EEPROM <Condtype> PORTA_TEMP_LOW_ALA <…
1.3.6.1.4.1.20044.14.2.2.2.18.8ScalarpmoscAlmPortaTempHighAlaread-onlycurrentSFP A Temp High :Alarm indicating that the SFP temperature of port A is higher than the threshold value written in the SFP EEPROM <Condtype> PORTA_TEMP_HIGH_AL…
1.3.6.1.4.1.20044.14.2.2.2.18.15ScalarpmoscAlmPortaRxPwrLowAlaread-onlycurrentSFP A Rx Power Low :Alarm indicating that the SFP input power of port A is lower than the threshold value written in the SFP EEPROM <Condtype> PORTA_RX_PWR_LOW…
1.3.6.1.4.1.20044.14.2.2.2.18.16ScalarpmoscAlmPortaRxPwrHighAlaread-onlycurrentSFP A Rx Power High :Alarm indicating that the SFP input power of port A is higher than the threshold value written in the SFP EEPROM <Condtype> PORTA_RX_PWR_H…
1.3.6.1.4.1.20044.14.2.2.3NodepmoscAlmClientCrit
1.3.6.1.4.1.20044.14.2.2.3.8NodepmoscAlmsynthAlm8
1.3.6.1.4.1.20044.14.2.2.3.8.1ScalarpmoscAlmPortaSfpAbsentread-onlycurrentSFP A Absent :This OID indicates that the SFP module A is not present. <Help> This alarm indicates if the port A transceiver is present. <Condtype> PORTA_SFP_A…
1.3.6.1.4.1.20044.14.2.2.3.8.2ScalarpmoscAlmPortaDdmAbsentread-onlycurrentDDM Supported On SFP A :This OID indicates that the SFP module A does not support Digital Diagnostic Monitoring Functions <Help> This status indicates if the p…
1.3.6.1.4.1.20044.14.2.2.3.8.4ScalarpmoscAlmPortaHwFailread-onlycurrentPort A HW Failure :This OID indicates a hardware failure on the port A <Condtype> PORTA_HW_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlar…
1.3.6.1.4.1.20044.14.2.2.3.8.5ScalarpmoscAlmPortaLsdread-onlycurrentSFP A Laser Shutdown :This OID indicates the optical output power is off on port A <Help> This status indicates if the port A transceiver laser is ON or OFF <C…
1.3.6.1.4.1.20044.14.2.2.3.8.6ScalarpmoscAlmPortaLocalOosread-onlycurrentSFP A In Service :This OID indicates that the Port A is In Service (1) of Out or Service (2) <Help> This status indicates if the port A is in service <Condtype…
1.3.6.1.4.1.20044.14.2.2.3.8.9ScalarpmoscAlmPortaDdmWarningread-onlycurrentWarning DDM On SFP A :This OID indicates a warning is present coming out of optical interface DDM on port A <Help> This alarm indicates if a DDM Warning has be…
1.3.6.1.4.1.20044.14.2.2.3.8.10ScalarpmoscAlmPortaDdmAlmread-onlycurrentAlarm DDM On SFP A :This OID indicates an alarm is present coming out of optical interface DDM on port A <Help> This alarm indicates if a DDM Alarm has been de…
1.3.6.1.4.1.20044.14.2.2.3.8.12ScalarpmoscAlmPortaFailread-onlycurrentPort A Failure :This OID indicates a failure on the port A <Condtype> PORTA_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12) <Polarit…
1.3.6.1.4.1.20044.14.2.2.3.16NodepmoscAlmportaAccessioAlm
1.3.6.1.4.1.20044.14.2.2.3.16.1ScalarpmoscAlmPortaLasFailread-onlycurrentSFP A Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the port A (this alarm reports the transmitter failure alarm generated …
1.3.6.1.4.1.20044.14.2.2.3.16.4ScalarpmoscAlmPortaLosread-onlycurrentLoss Of Optical Signal On SFP A :This OID indicates that no signal is present on the SFP A <Help> This alarm indicates if an optical signal is detected on the …
1.3.6.1.4.1.20044.14.2.3NodepmoscAlmLine
1.3.6.1.4.1.20044.14.2.3.1NodepmoscAlmLineNurg
1.3.6.1.4.1.20044.14.2.3.1.28NodepmoscAlmportbSfpWarnDdm
1.3.6.1.4.1.20044.14.2.3.1.28.1ScalarpmoscAlmPortbTxPwLowWngread-onlycurrentSFP B Tx Power Low Warning :Warning indicating that the SFP output power of port B is lower than the threshold value written in the SFP EEPROM <Condtype> PORTB…
1.3.6.1.4.1.20044.14.2.3.1.28.2ScalarpmoscAlmPortbTxPwrHighWngread-onlycurrentSFP B Tx Power High Warning :Warning indicating that the SFP output power of port B is higher than the threshold value written in the SFP EEPROM <Condtype> POR…
1.3.6.1.4.1.20044.14.2.3.1.28.3ScalarpmoscAlmPortbTxBiasLowWngread-onlycurrentSFP B Bias Low Warning :Warning indicating that the SFP laser bias current of port B is lower than the threshold value written in the SFP EEPROM <Condtype> POR…
1.3.6.1.4.1.20044.14.2.3.1.28.4ScalarpmoscAlmPortbTxBiasHighWngread-onlycurrentSFP B Bias High Warning :Warning indicating that the SFP laser bias current of port B is higher than the threshold value written in the SFP EEPROM <Condtype> P…
1.3.6.1.4.1.20044.14.2.3.1.28.7ScalarpmoscAlmPortbTempLowWngread-onlycurrentSFP B Temp Low Warning :Warning indicating that the SFP temperature of port B is lower than the threshold value written in the SFP EEPROM <Condtype> PORTB_TEMP…
1.3.6.1.4.1.20044.14.2.3.1.28.8ScalarpmoscAlmPortbTempHighWngread-onlycurrentSFP B Temp High Warning :Warning indicating that the SFP temperature of port B is higher than the threshold value written in the SFP EEPROM <Condtype> PORTB_TE…
1.3.6.1.4.1.20044.14.2.3.1.28.15ScalarpmoscAlmPortbRxPwrLowWngread-onlycurrentSFP B Rx Power Low Warning :Warning indicating that the SFP input power of port B is lower than the threshold value written in the SFP EEPROM <Condtype> PORTB_…
1.3.6.1.4.1.20044.14.2.3.1.28.16ScalarpmoscAlmPortbRxPwrHighWngread-onlycurrentSFP B Rx Power High Warning :Warning indicating that the SFP input power of port B is higher than the threshold value written in the SFP EEPROM <Condtype> PORT…
1.3.6.1.4.1.20044.14.2.3.2NodepmoscAlmLineUrg
1.3.6.1.4.1.20044.14.2.3.2.26NodepmoscAlmportbSfpAlmDdm
1.3.6.1.4.1.20044.14.2.3.2.26.1ScalarpmoscAlmPortbTxPwrLowAlaread-onlycurrentSFP B Tx Power Low :Alarm indicating that the SFP output power of port B is lower than the threshold value written in the SFP EEPROM <Condtype> PORTB_TX_PWR_LO…
1.3.6.1.4.1.20044.14.2.3.2.26.2ScalarpmoscAlmPortbTxPwrHighAlaread-onlycurrentSFP B Tx Power High :Alarm indicating that the SFP output power of port B is higher than the threshold value written in the SFP EEPROM <Condtype> PORTB_TX_PWR_…
1.3.6.1.4.1.20044.14.2.3.2.26.3ScalarpmoscAlmPortbTxBiasLowAlaread-onlycurrentSFP B Bias Low :Alarm indicating that the SFP laser bias current of port B is lower than the threshold value written in the SFP EEPROM <Condtype> PORTB_TX_BIAS…
1.3.6.1.4.1.20044.14.2.3.2.26.4ScalarpmoscAlmPortbTxBiasHighAlaread-onlycurrentSFP B Bias High :Alarm indicating that the SFP laser bias current of port B is higher than the threshold value written in the SFP EEPROM <Condtype> PORTB_TX_BI…
1.3.6.1.4.1.20044.14.2.3.2.26.7ScalarpmoscAlmPortbTempLowAlaread-onlycurrentSFP B Temp Low :Alarm indicating that the SFP temperature of port B is lower than the threshold value written in the SFP EEPROM <Condtype> PORTB_TEMP_LOW_ALA <…
1.3.6.1.4.1.20044.14.2.3.2.26.8ScalarpmoscAlmPortbTempHighAlaread-onlycurrentSFP B Temp High :Alarm indicating that the SFP temperature of port B is higher than the threshold value written in the SFP EEPROM <Condtype> PORTB_TEMP_HIGH_AL…
1.3.6.1.4.1.20044.14.2.3.2.26.15ScalarpmoscAlmPortbRxPwrLowAlaread-onlycurrentSFP B Rx Power Low :Alarm indicating that the SFP input power of port B is lower than the threshold value written in the SFP EEPROM <Condtype> PORTB_RX_PWR_LOW…
1.3.6.1.4.1.20044.14.2.3.2.26.16ScalarpmoscAlmPortbRxPwrHighAlaread-onlycurrentSFP B Rx Power High :Alarm indicating that the SFP input power of port B is higher than the threshold value written in the SFP EEPROM <Condtype> PORTB_RX_PWR_H…
1.3.6.1.4.1.20044.14.2.3.3NodepmoscAlmLineCrit
1.3.6.1.4.1.20044.14.2.3.3.7NodepmoscAlmsynthAlm7
1.3.6.1.4.1.20044.14.2.3.3.7.1ScalarpmoscAlmPortbSfpAbsentread-onlycurrentSFP B Absent :This OID indicates that the SFP module B is not present. <Help> This alarm indicates if the port B transceiver is present. <Condtype> PORTB_SFP_A…
1.3.6.1.4.1.20044.14.2.3.3.7.2ScalarpmoscAlmPortbDdmAbsentread-onlycurrentDDM Supported On SFP B :This OID indicates that the SFP module B does not support Digital Diagnostic Monitoring Functions <Help> This status indicates if the p…
1.3.6.1.4.1.20044.14.2.3.3.7.4ScalarpmoscAlmPortbHwFailread-onlycurrentPort B HW Failure :This OID indicates a hardware failure on the port B <Condtype> PORTB_HW_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlar…
1.3.6.1.4.1.20044.14.2.3.3.7.5ScalarpmoscAlmPortbLsdread-onlycurrentSFP B Laser Shutdown :This OID indicates the optical output power is off on port B <Help> This status indicates if the port B transceiver laser is ON or OFF <C…
1.3.6.1.4.1.20044.14.2.3.3.7.6ScalarpmoscAlmPortbLocalOosread-onlycurrentSFP B In Service :This OID indicates that the Port B is In Service (1) of Out or Service (2) <Help> This status indicates if the port B is in service <Condtype…
1.3.6.1.4.1.20044.14.2.3.3.7.9ScalarpmoscAlmPortbDdmWarningread-onlycurrentWarning DDM On SFP B :This OID indicates a warning is present coming out of optical interface DDM on port B <Help> This alarm indicates if a DDM Warning has be…
1.3.6.1.4.1.20044.14.2.3.3.7.10ScalarpmoscAlmPortbDdmAlmread-onlycurrentAlarm DDM On SFP B :This OID indicates an alarm is present coming out of optical interface DDM on port B <Help> This alarm indicates if a DDM Alarm has been de…
1.3.6.1.4.1.20044.14.2.3.3.7.12ScalarpmoscAlmPortbFailread-onlycurrentPort B Failure :This OID indicates a failure on the port B <Condtype> PORTB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12) <Polarit…
1.3.6.1.4.1.20044.14.2.3.3.24NodepmoscAlmportbAccessioAlm
1.3.6.1.4.1.20044.14.2.3.3.24.1ScalarpmoscAlmPortbLasFailread-onlycurrentSFP B Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the port A (this alarm reports the transmitter failure alarm generated …
1.3.6.1.4.1.20044.14.2.3.3.24.4ScalarpmoscAlmPortbLosread-onlycurrentLoss Of Optical Signal On SFP B :This OID indicates that no signal is present on the SFP B <Help> This alarm indicates if an optical signal is detected on the …
1.3.6.1.4.1.20044.14.3Nodepmoscmeasures
1.3.6.1.4.1.20044.14.3.1NodepmoscMesrOther
1.3.6.1.4.1.20044.14.3.2NodepmoscMesrClient
1.3.6.1.4.1.20044.14.3.2.16ScalarpmoscMesrportaTemperatureread-onlycurrentSFP A Temperature :This OID gives the temperature of the SFP A, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit = C) <Help> This…
1.3.6.1.4.1.20044.14.3.2.17ScalarpmoscMesrportaVoltread-onlycurrentSFP A Power Supply :This OID gives the voltage of the SFP A, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/10000) (Unit = V) <Help> This meas…
1.3.6.1.4.1.20044.14.3.2.18ScalarpmoscMesrportaTxBiasread-onlycurrentSFP A Laser Bias :This OID gives the bias value of the SFP A, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <Help> This measure…
1.3.6.1.4.1.20044.14.3.2.19ScalarpmoscMesrportaTxPowerread-onlycurrentSFP A Tx Power :This OID gives the transmit power value of the SFP A, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <H…
1.3.6.1.4.1.20044.14.3.2.20ScalarpmoscMesrportaRxPowerread-onlycurrentSFP A Rx Power :This OID gives the receive power value of the SFP A, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <He…
1.3.6.1.4.1.20044.14.3.3NodepmoscMesrLine
1.3.6.1.4.1.20044.14.3.3.24ScalarpmoscMesrportbTemperatureread-onlycurrentSFP B Temperature :This OID gives the temperature of the SFP B, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit = C) <Help> This…
1.3.6.1.4.1.20044.14.3.3.25ScalarpmoscMesrportbVoltread-onlycurrentSFP B Power Supply :This OID gives the voltage of the SFP B, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/10000) (Unit = V) <Help> This meas…
1.3.6.1.4.1.20044.14.3.3.26ScalarpmoscMesrportbTxBiasread-onlycurrentSFP B Laser Bias :This OID gives the bias value of the SFP B, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <Help> This measure…
1.3.6.1.4.1.20044.14.3.3.27ScalarpmoscMesrportbTxPowerread-onlycurrentSFP B Tx Power :This OID gives the transmit power value of the SFP B, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <H…
1.3.6.1.4.1.20044.14.3.3.28ScalarpmoscMesrportbRxPowerread-onlycurrentSFP B Rx Power :This OID gives the receive power value of the SFP B, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <He…
1.3.6.1.4.1.20044.14.6NodepmosccontrolsWrite
1.3.6.1.4.1.20044.14.6.1NodepmoscCtrlOther
1.3.6.1.4.1.20044.14.6.1.0NodepmoscCtrlsynth0
1.3.6.1.4.1.20044.14.6.1.0.1ScalarpmoscCtrlConfLoadread-writecurrentLoad Configuration Tables :When set this enables loading from flash configuration1 into the module.
1.3.6.1.4.1.20044.14.6.1.0.9ScalarpmoscCtrlConfFlashread-writecurrentWrite Configuration Tables :This bit saves the current configuration of the module as configuration in the flash. <Help> This control saves the customer config…
1.3.6.1.4.1.20044.14.6.1.0.13ScalarpmoscCtrlConfClearread-writecurrentClear Configuration Tables :This bit clears the configuration tables from configuration in the flash. <Help> This control restores the default configuration of…
1.3.6.1.4.1.20044.14.6.1.4NodepmoscCtrlsynth4
1.3.6.1.4.1.20044.14.6.1.4.1ScalarpmoscCtrlCorrelatOnread-writecurrentEnable Alarm Correlation :This OID enables the alarm correlation in the PM.
1.3.6.1.4.1.20044.14.6.1.4.2ScalarpmoscCtrlCorrelatOffread-writecurrentDisable Alarm Correlation :This OID disables the alarm correlation in the PM.
1.3.6.1.4.1.20044.14.6.1.5NodepmoscCtrlswMgnt
1.3.6.1.4.1.20044.14.6.1.5.2ScalarpmoscCtrlColdResetread-writecurrentSoftware Cold Reset :This OID, when set, causes a cold reset of the Software. This reset is traffic affecting, and the configuration of Software is reloaded on…
1.3.6.1.4.1.20044.14.6.1.5.3ScalarpmoscCtrlWarmResetread-writecurrentSoftware Warm Reset :This OID, when set, causes a warm reset of the Software. This reset is not traffic affecting, and the configuration of the Sofwtare remain…
1.3.6.1.4.1.20044.14.6.1.64NodepmoscCtrlledTest
1.3.6.1.4.1.20044.14.6.1.64.1ScalarpmoscCtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.14.6.1.64.2ScalarpmoscCtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.14.6.1.64.3ScalarpmoscCtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.14.6.1.65NodepmoscCtrlmoduleOosMode
1.3.6.1.4.1.20044.14.6.1.65.1ScalarpmoscCtrlModuleOosModeread-writecurrentPM Out Of Service :This OID sets the PM Out Of Service <Help> This control defines the service state of the complete module
1.3.6.1.4.1.20044.14.6.2NodepmoscCtrlClient
1.3.6.1.4.1.20044.14.6.2.16NodepmoscCtrlportaSfpOnoff
1.3.6.1.4.1.20044.14.6.2.16.1ScalarpmoscCtrlPortaSfpOnoffread-writecurrentSFP A Optical Laser Shutdown :This OID switches off the SFP A <Help> This control defines the laser state of the port A transceiver
1.3.6.1.4.1.20044.14.6.2.17NodepmoscCtrlportaOosMode
1.3.6.1.4.1.20044.14.6.2.17.1ScalarpmoscCtrlPortaOosModeread-writecurrentSFP A Port Out Of Service :This OID sets the Port A Out Of Service <Help> This controls defines the service state of the port A
1.3.6.1.4.1.20044.14.6.3NodepmoscCtrlLine
1.3.6.1.4.1.20044.14.6.3.24NodepmoscCtrlportbSfpOnoff
1.3.6.1.4.1.20044.14.6.3.24.1ScalarpmoscCtrlPortbSfpOnoffread-writecurrentSFP B Optical Laser Shutdown :This OID switches off the SFP B <Help> This control defines the laser state of the port B transceiver
1.3.6.1.4.1.20044.14.6.3.25NodepmoscCtrlportbOosMode
1.3.6.1.4.1.20044.14.6.3.25.1ScalarpmoscCtrlPortbOosModeread-writecurrentSFP B Port Out Of Service :This OID sets the Port B Out Of Service <Help> This controls defines the service state of the port B
1.3.6.1.4.1.20044.14.7Nodepmoscri
1.3.6.1.4.1.20044.14.7.2ScalarpmoscRinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.14.7.4ScalarpmoscRinvHwPlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.14.7.5ScalarpmoscRinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.14.7.6ScalarpmoscRinvPortASFPread-onlycurrentInventory for the SFP: This OID contains the inventory for the Port A SFP
1.3.6.1.4.1.20044.14.7.7ScalarpmoscRinvPortBSFPread-onlycurrentInventory for the SFP: This OID contains the inventory for the Port B SFP
1.3.6.1.4.1.20044.14.9NodepmoscConfig
1.3.6.1.4.1.20044.14.9.1NodepmoscCfgLsd
1.3.6.1.4.1.20044.14.9.2NodepmoscCfgStartUp
1.3.6.1.4.1.20044.14.9.2.1NodepmosctableclientStartup
1.3.6.1.4.1.20044.14.9.2.1.2ScalarpmoscCfgportaSfpCtrlread-writecurrentDefault Settings on Port A :This register configures the default initialisation settings on port A.
1.3.6.1.4.1.20044.14.9.2.1.3ScalarpmoscCfgportaOosModeread-writecurrentDefault Settings on Port A :This register configures the default initialisation settings on port A.
1.3.6.1.4.1.20044.14.9.2.2NodepmosctablelineStartup
1.3.6.1.4.1.20044.14.9.2.2.2ScalarpmoscCfgportbSfpCtrlread-writecurrentDefault Settings on Port B :This register configures the default initialisation settings on port B.
1.3.6.1.4.1.20044.14.9.2.2.3ScalarpmoscCfgportbOosModeread-writecurrentDefault Settings on Port B :This register configures the default initialisation settings on port B.
1.3.6.1.4.1.20044.14.9.3NodepmoscCfgLabels
1.3.6.1.4.1.20044.14.9.3.1TablepmoscCfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.14.9.3.1.1RowpmoscCfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.14.9.3.1.1.1ColumnpmoscCfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.14.9.3.1.1.3ColumnpmoscCfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.14.9.3.2TablepmoscCfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.14.9.3.2.1RowpmoscCfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.14.9.3.2.1.1ColumnpmoscCfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.14.9.3.2.1.3ColumnpmoscCfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.14.9.257ScalarpmoscCfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.14.10Nodepmosctraps
1.3.6.1.4.1.20044.14.10.4ScalarpmosctrapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.14.10.30NotificationpmoscPortaTrapNotUrgentGoesOncurrentNot urgent Port A default is activated
1.3.6.1.4.1.20044.14.10.31NotificationpmoscPortaTrapNotUrgentGoesOffcurrentNot urgent Port A default disappeared
1.3.6.1.4.1.20044.14.10.32NotificationpmoscPortaTrapUrgentGoesOncurrentUrgent Port A default is activated
1.3.6.1.4.1.20044.14.10.33NotificationpmoscPortaTrapUrgentGoesOffcurrentUrgent Port A default disappeared
1.3.6.1.4.1.20044.14.10.34NotificationpmoscPortaTrapCritGoesOncurrentCritical Port A default is activated
1.3.6.1.4.1.20044.14.10.35NotificationpmoscPortaTrapCritGoesOffcurrentCritical Port A default disappeared
1.3.6.1.4.1.20044.14.10.40NotificationpmoscPortbNotUrgentGoesOncurrentNot urgent Port B default is activated
1.3.6.1.4.1.20044.14.10.41NotificationpmoscPortbNotUrgentGoesOffcurrentNot urgent Port B default disappeared
1.3.6.1.4.1.20044.14.10.42NotificationpmoscPortbUrgentGoesOncurrentUrgent Port B default is activated
1.3.6.1.4.1.20044.14.10.43NotificationpmoscPortbUrgentGoesOffcurrentUrgent Port B default disappeared
1.3.6.1.4.1.20044.14.10.44NotificationpmoscPortbCritGoesOncurrentCritical Port B default is activated
1.3.6.1.4.1.20044.14.10.45NotificationpmoscPortbCritGoesOffcurrentCritical Port B default disappeared
1.3.6.1.4.1.20044.14.10.50NotificationpmoscPowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.14.10.51NotificationpmoscPowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared