EKINOPS-PmOab-MIB
153 objects
MIB for the Ekinops pmoab hardware.
Imported Objects
| EKINOPS-MIB | EkiApiState EkiMeasureType EkiMode ekinops EkiOnOff EkiProtocol EkiState EkiSynchroMode |
| SNMPv2-SMI | Counter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20044.23 | Identitymodulepmoab | MIB for the Ekinops pmoab hardware. | ||
| 1.3.6.1.4.1.20044.23.2 | Nodepmoabalarms | |||
| 1.3.6.1.4.1.20044.23.2.1 | NodepmoabAlmOther | |||
| 1.3.6.1.4.1.20044.23.2.1.1 | NodepmoabAlmOtherNurg | |||
| 1.3.6.1.4.1.20044.23.2.1.1.2 | NodepmoabAlmsynthAlm2 | |||
| 1.3.6.1.4.1.20044.23.2.1.1.2.1 | ScalarpmoabAlmConfTableSave | read-only | current | PM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> other… |
| 1.3.6.1.4.1.20044.23.2.1.1.2.2 | ScalarpmoabAlmInvUpload | read-only | current | Inventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> other (1) <Alarmtype> other (1) <Polarit… |
| 1.3.6.1.4.1.20044.23.2.1.1.2.3 | ScalarpmoabAlmConfTableLoad | read-only | current | PM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> other (1) <Alarmt… |
| 1.3.6.1.4.1.20044.23.2.1.1.75 | NodepmoabAlmfoaWarnings | |||
| 1.3.6.1.4.1.20044.23.2.1.1.75.5 | ScalarpmoabAlm3v3LowWarning | read-only | current | 3V3 Low Warning :This OID indicates that the PM 3V3 voltage is lower than the Warning threshold <Condtype> 3V3_LOW_WARNING <Probcause> powerProblem (36) <Alarm… |
| 1.3.6.1.4.1.20044.23.2.1.1.75.6 | ScalarpmoabAlm3v3HighWarning | read-only | current | 3V3 High Warning :This OID indicates that the PM 3V3 voltage is higher than the Warning threshold <Condtype> 3V3_HIGH_WARNING <Probcause> powerProblem (36) <Al… |
| 1.3.6.1.4.1.20044.23.2.1.1.75.7 | ScalarpmoabAlmTermpLowWarning | read-only | current | Temperature Low Warning :This OID indicates that the PM temperature if lower than the Warning threshold <Condtype> TERMP_LOW_WARNING <Probcause> temperatureUna… |
| 1.3.6.1.4.1.20044.23.2.1.1.75.8 | ScalarpmoabAlmTempHighWarning | read-only | current | Temperature High Warning :This OID indicates that the PM temperature if higher than the Warning threshold <Condtype> TEMP_HIGH_WARNING <Probcause> temperatureU… |
| 1.3.6.1.4.1.20044.23.2.1.2 | NodepmoabAlmOtherUrg | |||
| 1.3.6.1.4.1.20044.23.2.1.2.74 | NodepmoabAlmfoaAlarms | |||
| 1.3.6.1.4.1.20044.23.2.1.2.74.5 | ScalarpmoabAlm3v3LowAlarm | read-only | current | 3V3 Low Alarm :This OID indicates that the PM 3V3 voltage is lower than the alarm threshold <Condtype> 3V3_LOW_ALARM <Probcause> powerProblem (36) <Alarmtype> … |
| 1.3.6.1.4.1.20044.23.2.1.2.74.6 | ScalarpmoabAlm3v3HighAlarm | read-only | current | 3V3 High Alarm :This OID indicates that the PM 3V3 voltage is higher than the alarm threshold <Condtype> 3V3_HIGH_ALARM <Probcause> powerProblem (36) <Alarmtyp… |
| 1.3.6.1.4.1.20044.23.2.1.2.74.7 | ScalarpmoabAlmTermpLowAlarm | read-only | current | Temperature Low Alarm :This OID indicates that the PM temperature if lower than the alarm threshold <Condtype> TERMP_LOW_ALARM <Probcause> temperatureUnaccepta… |
| 1.3.6.1.4.1.20044.23.2.1.2.74.8 | ScalarpmoabAlmTempHighAlarm | read-only | current | Temperature High Alarm :This OID indicates that the PM temperature is higher than the alarm threshold <Condtype> TEMP_HIGH_ALARM <Probcause> temperatureUnaccep… |
| 1.3.6.1.4.1.20044.23.2.1.3 | NodepmoabAlmOtherCrit | |||
| 1.3.6.1.4.1.20044.23.2.1.3.0 | NodepmoabAlmsynthAlm0 | |||
| 1.3.6.1.4.1.20044.23.2.1.3.0.1 | ScalarpmoabAlmMaintenanceMode | read-only | current | Maintenance Mode :This OID indicates that the PM is in maintenance mode <Help> This status indiates if the module is currently in maintenance mode <Condtype> M… |
| 1.3.6.1.4.1.20044.23.2.1.3.0.9 | ScalarpmoabAlmModGlobFail | read-only | current | Module Failure :This OID is set on detection of a failure originating from the PM <Condtype> MOD_GLOB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> sy… |
| 1.3.6.1.4.1.20044.23.2.1.3.0.10 | ScalarpmoabAlmUpEdfaInitNotCompl | read-only | current | Booster Not Initialized :This OID indicates that the initialisation of the Booster is not completed <Help> This status indicates if the Booster has been correc… |
| 1.3.6.1.4.1.20044.23.2.1.3.0.11 | ScalarpmoabAlmDwEdfaInitNotCompl | read-only | current | Pre-Amp Not Initialized :This OID indicates that the initialisation of the Pre-Amp is not completed <Condtype> DW_EDFA_INIT_NOT_COMPL <Probcause> other (1) <Al… |
| 1.3.6.1.4.1.20044.23.2.1.3.0.12 | ScalarpmoabAlmExtPumpNotLocked | read-only | current | External Pump1 Not Detected :This OID indicates that the first external pump is not detected by the amplifier module <Help> This alarm indicates if the first e… |
| 1.3.6.1.4.1.20044.23.2.1.3.0.15 | ScalarpmoabAlmDefFuseA | read-only | current | Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.23.2.1.3.0.16 | ScalarpmoabAlmDefFuseB | read-only | current | Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.23.2.2 | NodepmoabAlmClient | |||
| 1.3.6.1.4.1.20044.23.2.2.1 | NodepmoabAlmClientNurg | |||
| 1.3.6.1.4.1.20044.23.2.2.1.33 | NodepmoabAlmclientEdfaWarnings | |||
| 1.3.6.1.4.1.20044.23.2.2.1.33.3 | ScalarpmoabAlmClientInputPwrLowWarning | read-only | current | Booster Rx Pwr Low Warning :This OID indicates that the Receive Power is lower than the Warning theshold of the Booster Optical Module <Help> This warning indi… |
| 1.3.6.1.4.1.20044.23.2.2.1.33.4 | ScalarpmoabAlmClientInputPwrHighWarning | read-only | current | Booster Rx Pwr High Warning :This OID indicates that the Receive Power is higher than the Warning theshold of the Booster Optical Module <Help> This warning in… |
| 1.3.6.1.4.1.20044.23.2.2.2 | NodepmoabAlmClientUrg | |||
| 1.3.6.1.4.1.20044.23.2.2.2.32 | NodepmoabAlmclientEdfaAlarms1 | |||
| 1.3.6.1.4.1.20044.23.2.2.2.32.3 | ScalarpmoabAlmClientInputPwrLowAlarm | read-only | current | Booster Rx Pwr Low Alarm :This OID indicates that the Receive Power is lower than the alarm theshold of the Booster Optical Module <Help> This alarm indicates … |
| 1.3.6.1.4.1.20044.23.2.2.2.32.4 | ScalarpmoabAlmClientInputPwrHighAlarm | read-only | current | Booster Rx Pwr High Alarm :This OID indicates that the Receive Power is higher than the alarm theshold of the Booster Optical Module <Help> This alarm indicate… |
| 1.3.6.1.4.1.20044.23.2.2.3 | NodepmoabAlmClientCrit | |||
| 1.3.6.1.4.1.20044.23.2.2.3.8 | NodepmoabAlmsynthAlm8 | |||
| 1.3.6.1.4.1.20044.23.2.2.3.8.4 | ScalarpmoabAlmClientHwFail | read-only | current | Client Port HW Failure :This OID indicates a failure on Client port, most probably caused by a HW issue <Condtype> CLIENT_HW_FAIL <Probcause> equipmentMalfunct… |
| 1.3.6.1.4.1.20044.23.2.2.3.8.9 | ScalarpmoabAlmClientDdmWarning | read-only | current | Warning On Client Optical Module DDM :This OID indicates a warning is present coming out of Client optical interface DDM <Condtype> CLIENT_DDM_WARNING <Probcau… |
| 1.3.6.1.4.1.20044.23.2.2.3.8.10 | ScalarpmoabAlmClientDdmAlm | read-only | current | Alarm On Client Optical Module DDM :This OID indicates an alarm is present coming out of Client optical interface DDM <Condtype> CLIENT_DDM_ALM <Probcause> equ… |
| 1.3.6.1.4.1.20044.23.2.2.3.8.12 | ScalarpmoabAlmClientFail | read-only | current | Client Port Failure :This OID indicates a failure on the Client port <Condtype> CLIENT_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (1… |
| 1.3.6.1.4.1.20044.23.2.2.3.35 | NodepmoabAlmclientEdfaAlarms2 | |||
| 1.3.6.1.4.1.20044.23.2.2.3.35.4 | ScalarpmoabAlmClientEdfaLos | read-only | current | Booster Loss Of Signal :This OID indicates a Loss of Signal on the Booster Optical Module <Help> This alarm indicates if an optical signal is detected on the B… |
| 1.3.6.1.4.1.20044.23.2.3 | NodepmoabAlmLine | |||
| 1.3.6.1.4.1.20044.23.2.3.1 | NodepmoabAlmLineNurg | |||
| 1.3.6.1.4.1.20044.23.2.3.1.41 | NodepmoabAlmlineEdfaWarnings | |||
| 1.3.6.1.4.1.20044.23.2.3.1.41.1 | ScalarpmoabAlmLineGainLowWarning | read-only | current | Booster Gain Low Warning :This OID indicates that the Gain is lower than the Warning theshold of the Booster Module <Help> This alarm indicates if the Booster … |
| 1.3.6.1.4.1.20044.23.2.3.1.41.2 | ScalarpmoabAlmLineGainHighWarning | read-only | current | Booster Gain High Warning :This OID indicates that the Gain is higher than the Warning threshold of the Booster Module <Help> This alarm indicates if the Boost… |
| 1.3.6.1.4.1.20044.23.2.3.1.41.5 | ScalarpmoabAlmLineOutputPwrLowWarning | read-only | current | Booster Tx Pwr Low Warning :This OID indicates that the Transmit Power is lower than the Warning theshold of the Booster Optical Module <Help> This warning ind… |
| 1.3.6.1.4.1.20044.23.2.3.1.41.6 | ScalarpmoabAlmLineOutputPwrHighWarning | read-only | current | Booster Tx Pwr High Warning :This OID indicates that the Transmit Power is higher than the Warning theshold of the Booster Optical Module <Help> This warning i… |
| 1.3.6.1.4.1.20044.23.2.3.1.41.7 | ScalarpmoabAlmLineBiasLowWarning | read-only | current | Booster Bias Low Warning :This OID indicates that the Bias is lower than the Warning theshold of the Booster Optical Module <Help> This warning indicates if th… |
| 1.3.6.1.4.1.20044.23.2.3.1.41.8 | ScalarpmoabAlmLineBiasHighWarning | read-only | current | Booster Bias High Warning :This OID indicates that the Bias is higher than the Warning theshold of the Booster Optical Module <Help> This warning indicates if … |
| 1.3.6.1.4.1.20044.23.2.3.2 | NodepmoabAlmLineUrg | |||
| 1.3.6.1.4.1.20044.23.2.3.2.40 | NodepmoabAlmlineEdfaAlarms1 | |||
| 1.3.6.1.4.1.20044.23.2.3.2.40.1 | ScalarpmoabAlmLineGainLowAlarm | read-only | current | Booster Gain Low Alarm :This OID indicates that the Gain is lower than the alarm theshold of the Booster Module <Help> This alarm indicates if the Booster gain… |
| 1.3.6.1.4.1.20044.23.2.3.2.40.2 | ScalarpmoabAlmLineGainHighAlarm | read-only | current | Booster Gain High Alarm :This OID indicates that the Gain is higher than the alarm threshold of the Booster Module <Help> This alarm indicates if the Booster g… |
| 1.3.6.1.4.1.20044.23.2.3.2.40.5 | ScalarpmoabAlmLineOutputPwrLowAlarm | read-only | current | Booster Tx Pwr Low Alarm :This OID indicates that the Transmit Power is lower than the alarm theshold of the Booster Optical Module <Help> This alarm indicates… |
| 1.3.6.1.4.1.20044.23.2.3.2.40.6 | ScalarpmoabAlmLineOutputPwrHighAlarm | read-only | current | Booster Tx Pwr High Alarm :This OID indicates that the Transmit Power is higher than the alarm theshold of the Booster Optical Module <Help> This alarm indicat… |
| 1.3.6.1.4.1.20044.23.2.3.2.40.7 | ScalarpmoabAlmLineBiasLowAlarm | read-only | current | Booster Bias Low Alarm :This OID indicates that the Bias is lower than the alarm theshold of the Booster Optical Module <Help> This alarm indicates if the Boos… |
| 1.3.6.1.4.1.20044.23.2.3.2.40.8 | ScalarpmoabAlmLineBiasHighAlarm | read-only | current | Booster Bias High Alarm :This OID indicates that the Bias is higher than the alarm theshold of the Booster Optical Module <Help> This alarm indicates if the Bo… |
| 1.3.6.1.4.1.20044.23.2.3.3 | NodepmoabAlmLineCrit | |||
| 1.3.6.1.4.1.20044.23.2.3.3.7 | NodepmoabAlmsynthAlm7 | |||
| 1.3.6.1.4.1.20044.23.2.3.3.7.4 | ScalarpmoabAlmLineHwFail | read-only | current | Line Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Condtype> LINE_HW_FAIL <Probcause> equipmentMalfunction (1… |
| 1.3.6.1.4.1.20044.23.2.3.3.7.5 | ScalarpmoabAlmLineTxOff | read-only | current | Booster Optical Output Shutdown :This OID indicates the Booster optical output power is on <Help> This status indicates if the Booster laser pump is ON or OFF … |
| 1.3.6.1.4.1.20044.23.2.3.3.7.9 | ScalarpmoabAlmLineDdmWarning | read-only | current | Warning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line optical interface DDM <Condtype> LINE_DDM_WARNING <Probcause> eq… |
| 1.3.6.1.4.1.20044.23.2.3.3.7.10 | ScalarpmoabAlmLineDdmAlm | read-only | current | Alarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line optical interface DDM <Condtype> LINE_DDM_ALM <Probcause> equipment… |
| 1.3.6.1.4.1.20044.23.2.3.3.7.12 | ScalarpmoabAlmLineFail | read-only | current | Line Port Failure :This OID indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12) <Po… |
| 1.3.6.1.4.1.20044.23.2.3.3.43 | NodepmoabAlmlineEdfaAlarms2 | |||
| 1.3.6.1.4.1.20044.23.2.3.3.43.1 | ScalarpmoabAlmLineEdfaNr | read-only | current | Booster Optical Module Not Ready :This OID indicates that the Booster Optical Module is not ready <Help> This status indicates if the Booster has been correctl… |
| 1.3.6.1.4.1.20044.23.2.3.3.43.2 | ScalarpmoabAlmLineEdfaTecFail | read-only | current | Booster TEC Fail :This OID indicates that the TEC is in fail condition on the Booster Optical Module <Help> This alarm indicates if the TEC of the Booster is i… |
| 1.3.6.1.4.1.20044.23.2.3.3.43.3 | ScalarpmoabAlmLineEdfaLaserFail | read-only | current | Booster Pump Laser Fail :This OID indicates a Transmit Laser Fail on the Booster Optical Module <Help> This alarm indicates if the laser of the Booster is in f… |
| 1.3.6.1.4.1.20044.23.2.3.3.43.5 | ScalarpmoabAlmLineExtPumpEdfaLowCurrent | read-only | current | Booster External Pump1 Low Current :This OID indicates that the EDFA pump current of the first external pump linked to the Booster is too low <Help> This alarm… |
| 1.3.6.1.4.1.20044.23.3 | Nodepmoabmeasures | |||
| 1.3.6.1.4.1.20044.23.3.1 | NodepmoabMesrOther | |||
| 1.3.6.1.4.1.20044.23.3.1.72 | ScalarpmoabMesrtempMeas | read-only | current | Module Temperature :This OID gives the temperature of the PM (Unit = C) <Help> This measure gives the temperature of the module |
| 1.3.6.1.4.1.20044.23.3.1.73 | ScalarpmoabMesr3v3Meas | read-only | current | Module 3.3 Voltage :This OID gives the 3V3 voltage of the PM (Unit = V) <Help> This measure gives the 3V3 voltage of the module |
| 1.3.6.1.4.1.20044.23.3.2 | NodepmoabMesrClient | |||
| 1.3.6.1.4.1.20044.23.3.2.34 | ScalarpmoabMesrclientEdfaRxpwrMeas | read-only | current | Booster Rx Power :This OID gives the receive power value of the Booster Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Rx … |
| 1.3.6.1.4.1.20044.23.3.3 | NodepmoabMesrLine | |||
| 1.3.6.1.4.1.20044.23.3.3.40 | ScalarpmoabMesrlineEdfaBiasMeas | read-only | current | Booster Pump Laser Current :This OID gives the pump laser current of the Booster Optical Module (Current =AV/100) (Unit = mA) <Help> This measure gives the bia… |
| 1.3.6.1.4.1.20044.23.3.3.41 | ScalarpmoabMesrlineEdfaTxpwrMeas | read-only | current | Booster Tx Power :This OID gives the transmit power value of the Booster Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Tx… |
| 1.3.6.1.4.1.20044.23.3.3.43 | ScalarpmoabMesrlineEdfaGainMeas | read-only | current | Booster Gain :This OID gives the gain value of the Booster Module (Gain =(AV-32768)*0,005) (Unit = dB) <Help> This measure gives the optical gain of the Booster |
| 1.3.6.1.4.1.20044.23.6 | NodepmoabcontrolsWrite | |||
| 1.3.6.1.4.1.20044.23.6.1 | NodepmoabCtrlOther | |||
| 1.3.6.1.4.1.20044.23.6.1.0 | NodepmoabCtrlsynth0 | |||
| 1.3.6.1.4.1.20044.23.6.1.0.1 | ScalarpmoabCtrlConfLoad | read-write | current | Load Configuration Tables :When set this enables loading from flash configuration1 into the module. |
| 1.3.6.1.4.1.20044.23.6.1.0.9 | ScalarpmoabCtrlConfFlash | read-write | current | Write Configuration Tables :This bit saves the current configuration of the module as configuration in the flash. <Help> This control saves the customer config… |
| 1.3.6.1.4.1.20044.23.6.1.0.13 | ScalarpmoabCtrlConfClear | read-write | current | Clear Configuration Tables :This bit clears the configuration tables from configuration in the flash. <Help> This control restores the default configuration of… |
| 1.3.6.1.4.1.20044.23.6.1.5 | NodepmoabCtrlswMgnt | |||
| 1.3.6.1.4.1.20044.23.6.1.5.2 | ScalarpmoabCtrlColdReset | read-write | current | PM Cold Reset :This OID, when set, causes a cold reset of the Software. This reset is traffic affecting, and the configuration of Software is reloaded on start… |
| 1.3.6.1.4.1.20044.23.6.1.5.3 | ScalarpmoabCtrlWarmReset | read-write | current | PM Warm Reset :This OID, when set, causes a warm reset of the Software. This reset is not traffic affecting, and the configuration of the Sofwtare remains unch… |
| 1.3.6.1.4.1.20044.23.6.1.72 | NodepmoabCtrlpowerDown | |||
| 1.3.6.1.4.1.20044.23.6.1.72.1 | ScalarpmoabCtrlSoftPowerDown | read-write | current | Module Software Shutdown :This OID shuts down the PM Software <Help> This control initiates a shut down of software. |
| 1.3.6.1.4.1.20044.23.6.1.73 | NodepmoabCtrlledTest | |||
| 1.3.6.1.4.1.20044.23.6.1.73.1 | ScalarpmoabCtrlGreenLed | read-write | current | Green Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green |
| 1.3.6.1.4.1.20044.23.6.1.73.2 | ScalarpmoabCtrlRedLed | read-write | current | Red Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red |
| 1.3.6.1.4.1.20044.23.6.1.73.3 | ScalarpmoabCtrlLedOff | read-write | current | Leds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF |
| 1.3.6.1.4.1.20044.23.6.1.75 | NodepmoabCtrlmaintMode | |||
| 1.3.6.1.4.1.20044.23.6.1.75.1 | ScalarpmoabCtrlMaintenance | read-write | current | Module Maintenance Mode :This OID sets the PM in maintenance mode <Help> This control enables the maintenance mode of the module |
| 1.3.6.1.4.1.20044.23.6.2 | NodepmoabCtrlClient | |||
| 1.3.6.1.4.1.20044.23.6.3 | NodepmoabCtrlLine | |||
| 1.3.6.1.4.1.20044.23.6.3.40 | NodepmoabCtrllineEdfaLaserOff | |||
| 1.3.6.1.4.1.20044.23.6.3.40.1 | ScalarpmoabCtrlLineEdfaLaserOff | read-write | current | Booster Pump Laser Shutdown :This OID switches OFF the laser of the Booster Optical Module <Help> This control defines the laser state of the Booster |
| 1.3.6.1.4.1.20044.23.6.3.41 | ScalarpmoabCtrllineEdfaMode | read-write | current | Booster Module Mode :This OID selects the mode of the Booster Module <Help> This control defines the Booster Mode (0: Default mode, 2:Constant output power) |
| 1.3.6.1.4.1.20044.23.6.3.42 | ScalarpmoabCtrllineIlasSettingValue | read-write | current | Booster Laser Current Value :This OID sets the value of the laser current of the Booster Module (active only in constant current mode) (AV = Current *100) (Uni… |
| 1.3.6.1.4.1.20044.23.6.3.43 | ScalarpmoabCtrllinePlasSettingValue | read-write | current | Booster Pump Power Value :This OID sets the value of the laser power of the Booster Optical Module (active only in constant power mode) (AV=(Power/0,005) + 327… |
| 1.3.6.1.4.1.20044.23.6.3.44 | ScalarpmoabCtrllineGainSettingValue | read-write | current | Booster Gain Value :This OID sets the value of the gain of the Booster Module (active only in constant gain mode) (AV=(Gain/0,005) + 32768) (Unit = dB) |
| 1.3.6.1.4.1.20044.23.6.3.45 | ScalarpmoabCtrllineEffPwrOutSettingValue | read-write | current | Booster Effective Output Power :This OID sets the value of the effective output power (without noise power) of the Booster Module (active only in input power f… |
| 1.3.6.1.4.1.20044.23.7 | Nodepmoabri | |||
| 1.3.6.1.4.1.20044.23.7.2 | ScalarpmoabRinvReloadInventory | read-write | current | Reload the inventory: This OID triggers an inventory reload. |
| 1.3.6.1.4.1.20044.23.7.3 | ScalarpmoabRinvModulePlatform | read-only | current | Module platform description: This OID contains the description of the Module. |
| 1.3.6.1.4.1.20044.23.7.4 | ScalarpmoabRinvSwPlatform | read-only | current | SW platform description: This OID contains the description of the Software platform. |
| 1.3.6.1.4.1.20044.23.7.5 | ScalarpmoabRinvSwFoa | read-only | current | Optical device driver description: This OID contains the description of the driver of the optical devices (Booster and Pre-Amp) |
| 1.3.6.1.4.1.20044.23.7.6 | TablepmoabRinvBoosterTable | not-accessible | current | List of the Boosters on the selected module |
| 1.3.6.1.4.1.20044.23.7.6.1 | RowpmoabRinvBoosterEntry | not-accessible | current | Row definition for the Boosters table |
| 1.3.6.1.4.1.20044.23.7.6.1.1 | ColumnpmoabRinvBoosterIndex | read-only | current | Index for Booster table |
| 1.3.6.1.4.1.20044.23.7.6.1.2 | ColumnpmoabRinvBooster | read-only | current | Inventory for the Booster: This OID contains the inventory for the Booster |
| 1.3.6.1.4.1.20044.23.9 | NodepmoabConfig | |||
| 1.3.6.1.4.1.20044.23.9.1 | NodepmoabCfgNoValue | |||
| 1.3.6.1.4.1.20044.23.9.1.1 | NodepmoabtableclientStartup | |||
| 1.3.6.1.4.1.20044.23.9.2 | NodepmoabCfgLineStartUp | |||
| 1.3.6.1.4.1.20044.23.9.2.1 | NodepmoabtablelineStartup | |||
| 1.3.6.1.4.1.20044.23.9.2.1.2 | ScalarpmoabCfglineEdfaLaserCtrl | read-write | current | Default Settings on Line Laser :This OID configures the default initialisation settings on the line laser. |
| 1.3.6.1.4.1.20044.23.9.2.1.3 | ScalarpmoabCfglineEdfaLaserMode | read-write | current | Default Settings on Line mode :This OID configures the default mode on the line amplifier. |
| 1.3.6.1.4.1.20044.23.9.3 | NodepmoabCfgLabels | |||
| 1.3.6.1.4.1.20044.23.9.3.1 | TablepmoabCfgLabelclientTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.23.9.3.1.1 | RowpmoabCfgLabelclientEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.23.9.3.1.1.1 | ColumnpmoabCfgLabelclientIndex | read-only | current | Index definition for the labelclient table |
| 1.3.6.1.4.1.20044.23.9.3.1.1.3 | ColumnpmoabCfgLabelclientPortn | read-write | current | Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. |
| 1.3.6.1.4.1.20044.23.9.3.2 | TablepmoabCfgLabellineTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.23.9.3.2.1 | RowpmoabCfgLabellineEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.23.9.3.2.1.1 | ColumnpmoabCfgLabellineIndex | read-only | current | Index definition for the labelline table |
| 1.3.6.1.4.1.20044.23.9.3.2.1.3 | ColumnpmoabCfgLabellinePortn | read-write | current | Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. |
| 1.3.6.1.4.1.20044.23.9.257 | ScalarpmoabCfgWriteConfiguration | read-write | current | Write configuration to module:This OID writes the complete configuration to the module |
| 1.3.6.1.4.1.20044.23.10 | Nodepmoabtraps | |||
| 1.3.6.1.4.1.20044.23.10.4 | ScalarpmoabtrapBoardNumber | read-only | current | Last module which generates a trap |
| 1.3.6.1.4.1.20044.23.10.30 | NotificationpmoabLineTrapNotUrgentGoesOn | current | Not urgent Line default is activated | |
| 1.3.6.1.4.1.20044.23.10.31 | NotificationpmoabLineTrapNotUrgentGoesOff | current | Not urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.23.10.32 | NotificationpmoabLineTrapUrgentGoesOn | current | Urgent Line default is activated | |
| 1.3.6.1.4.1.20044.23.10.33 | NotificationpmoabLineTrapUrgentGoesOff | current | Urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.23.10.34 | NotificationpmoabLineTrapCritGoesOn | current | Critical Line default is activated | |
| 1.3.6.1.4.1.20044.23.10.35 | NotificationpmoabLineTrapCritGoesOff | current | Critical Line default disappeared | |
| 1.3.6.1.4.1.20044.23.10.40 | NotificationpmoabClientTrapNotUrgentGoesOn | current | Not urgent client default is activated | |
| 1.3.6.1.4.1.20044.23.10.41 | NotificationpmoabClientTrapNotUrgentGoesOff | current | Not urgent client default disappeared | |
| 1.3.6.1.4.1.20044.23.10.42 | NotificationpmoabClientTrapUrgentGoesOn | current | Urgent client default is activated | |
| 1.3.6.1.4.1.20044.23.10.43 | NotificationpmoabClientTrapUrgentGoesOff | current | Urgent client default disappeared | |
| 1.3.6.1.4.1.20044.23.10.44 | NotificationpmoabClientTrapCritGoesOn | current | Critical client default is activated | |
| 1.3.6.1.4.1.20044.23.10.45 | NotificationpmoabClientTrapCritGoesOff | current | Critical client default disappeared | |
| 1.3.6.1.4.1.20044.23.10.50 | NotificationpmoabPowerTrapUrgentGoesOn | current | Urgent power supply default is activated | |
| 1.3.6.1.4.1.20044.23.10.51 | NotificationpmoabPowerTrapUrgentGoesOff | current | Urgent power supply default disappeared |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| PmoabboosterMode | INTEGER { oaboosterdefaultmode(0), oaboosterconstantcurrentmode(1), oaboosterconstantpowermode(2) } | current | Different modes on OA booster |