EKINOPS-PmOail-MIB
193 objects
Creation
Imported Objects
| EKINOPS-MIB | EkiApiState EkiMeasureType EkiMode ekinops EkiOnOff EkiProtocol EkiState EkiSynchroMode |
| SNMPv2-SMI | Counter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20044.36 | Identitymodulepmoail | Creation | ||
| 1.3.6.1.4.1.20044.36.2 | Nodepmoailalarms | |||
| 1.3.6.1.4.1.20044.36.2.1 | NodepmoailAlmOther | |||
| 1.3.6.1.4.1.20044.36.2.1.1 | NodepmoailAlmOtherNurg | |||
| 1.3.6.1.4.1.20044.36.2.1.1.2 | NodepmoailAlmsynthAlm2 | |||
| 1.3.6.1.4.1.20044.36.2.1.1.2.1 | ScalarpmoailAlmConfTableSave | read-only | current | PM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> other… |
| 1.3.6.1.4.1.20044.36.2.1.1.2.2 | ScalarpmoailAlmInvUpload | read-only | current | Inventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> other (1) <Alarmtype> other (1) <Polarit… |
| 1.3.6.1.4.1.20044.36.2.1.1.2.3 | ScalarpmoailAlmConfTableLoad | read-only | current | PM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> other (1) <Alarmt… |
| 1.3.6.1.4.1.20044.36.2.1.1.75 | NodepmoailAlmfoaWarnings | |||
| 1.3.6.1.4.1.20044.36.2.1.1.75.5 | ScalarpmoailAlm3v3LowWarning | read-only | current | 3V3 Low Warning :This OID indicates that the PM 3V3 voltage is lower than the Warning threshold <Condtype> 3V3_LOW_WARNING <Probcause> powerProblem (36) <Alarm… |
| 1.3.6.1.4.1.20044.36.2.1.1.75.6 | ScalarpmoailAlm3v3HighWarning | read-only | current | 3V3 High Warning :This OID indicates that the PM 3V3 voltage is higher than the Warning threshold <Condtype> 3V3_HIGH_WARNING <Probcause> powerProblem (36) <Al… |
| 1.3.6.1.4.1.20044.36.2.1.1.75.7 | ScalarpmoailAlmTermpLowWarning | read-only | current | Temperature Low Warning :This OID indicates that the PM temperature if lower than the Warning threshold <Condtype> TERMP_LOW_WARNING <Probcause> temperatureUna… |
| 1.3.6.1.4.1.20044.36.2.1.1.75.8 | ScalarpmoailAlmTempHighWarning | read-only | current | Temperature High Warning :This OID indicates that the PM temperature if higher than the Warning threshold <Condtype> TEMP_HIGH_WARNING <Probcause> temperatureU… |
| 1.3.6.1.4.1.20044.36.2.1.2 | NodepmoailAlmOtherUrg | |||
| 1.3.6.1.4.1.20044.36.2.1.2.74 | NodepmoailAlmfoaAlarms | |||
| 1.3.6.1.4.1.20044.36.2.1.2.74.5 | ScalarpmoailAlm3v3LowAlarm | read-only | current | 3V3 Low Alarm :This OID indicates that the PM 3V3 voltage is lower than the alarm threshold <Condtype> 3V3_LOW_ALARM <Probcause> powerProblem (36) <Alarmtype> … |
| 1.3.6.1.4.1.20044.36.2.1.2.74.6 | ScalarpmoailAlm3v3HighAlarm | read-only | current | 3V3 High Alarm :This OID indicates that the PM 3V3 voltage is higher than the alarm threshold <Condtype> 3V3_HIGH_ALARM <Probcause> powerProblem (36) <Alarmtyp… |
| 1.3.6.1.4.1.20044.36.2.1.2.74.7 | ScalarpmoailAlmTermpLowAlarm | read-only | current | Temperature Low Alarm :This OID indicates that the PM temperature if lower than the alarm threshold <Condtype> TERMP_LOW_ALARM <Probcause> temperatureUnaccepta… |
| 1.3.6.1.4.1.20044.36.2.1.2.74.8 | ScalarpmoailAlmTempHighAlarm | read-only | current | Temperature High Alarm :This OID indicates that the PM temperature is higher than the alarm threshold <Condtype> TEMP_HIGH_ALARM <Probcause> temperatureUnaccep… |
| 1.3.6.1.4.1.20044.36.2.1.3 | NodepmoailAlmOtherCrit | |||
| 1.3.6.1.4.1.20044.36.2.1.3.0 | NodepmoailAlmsynthAlm0 | |||
| 1.3.6.1.4.1.20044.36.2.1.3.0.1 | ScalarpmoailAlmMaintenanceMode | read-only | current | Maintenance Mode :This OID indicates that the PM is in maintenance mode <Help> This status indiates if the module is currently in maintenance mode <Condtype> M… |
| 1.3.6.1.4.1.20044.36.2.1.3.0.9 | ScalarpmoailAlmModGlobFail | read-only | current | Module Failure :This OID is set on detection of a failure originating from the PM <Condtype> MOD_GLOB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> sy… |
| 1.3.6.1.4.1.20044.36.2.1.3.0.10 | ScalarpmoailAlmUpEdfaInitNotCompl | read-only | current | IL1 Not Initialized :This OID indicates that the initialisation of the IL1 is not completed <Help> This status indicates if the IL1 has been correctly initiali… |
| 1.3.6.1.4.1.20044.36.2.1.3.0.11 | ScalarpmoailAlmDwEdfaInitNotCompl | read-only | current | IL2 Not Initialized :This OID indicates that the initialisation of the IL2 is not completed <Help> This status indicates if the IL2 has been correctly initiali… |
| 1.3.6.1.4.1.20044.36.2.1.3.0.12 | ScalarpmoailAlmExtPumpNotLocked | read-only | current | External Pump1 Not Detected :This OID indicates that the first external pump is not detected by the amplifier module <Help> This alarm indicates if the first e… |
| 1.3.6.1.4.1.20044.36.2.1.3.0.15 | ScalarpmoailAlmDefFuseA | read-only | current | Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.36.2.1.3.0.16 | ScalarpmoailAlmDefFuseB | read-only | current | Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.36.2.2 | NodepmoailAlmClient | |||
| 1.3.6.1.4.1.20044.36.2.2.1 | NodepmoailAlmClientNurg | |||
| 1.3.6.1.4.1.20044.36.2.2.1.33 | NodepmoailAlmclientEdfaWarnings | |||
| 1.3.6.1.4.1.20044.36.2.2.1.33.1 | ScalarpmoailAlmClientGainLowWarning | read-only | current | IL2 Gain Low Warning :This OID indicates that the Gain is lower than the Warning theshold of the IL2 Module <Help> This alarm indicates if the IL2 gain is too … |
| 1.3.6.1.4.1.20044.36.2.2.1.33.2 | ScalarpmoailAlmClientGainHighWarning | read-only | current | IL2 Gain High Warning :This OID indicates that the Gain is higher than the Warning threshold of the IL2 Module <Help> This alarm indicates if the IL2 gain is t… |
| 1.3.6.1.4.1.20044.36.2.2.1.33.3 | ScalarpmoailAlmClientInputPwrLowWarning | read-only | current | IL1 Rx Pwr Low Warning :This OID indicates that the Receive Power is lower than the Warning theshold of the IL1 Optical Module <Help> This warning indicates if… |
| 1.3.6.1.4.1.20044.36.2.2.1.33.4 | ScalarpmoailAlmClientInputPwrHighWarning | read-only | current | IL1 Rx Pwr High Warning :This OID indicates that the Receive Power is higher than the Warning theshold of the IL1 Optical Module <Help> This warning indicates … |
| 1.3.6.1.4.1.20044.36.2.2.1.33.5 | ScalarpmoailAlmClientOutputPwrLowWarning | read-only | current | IL2 Tx Pwr Low Warning :This OID indicates that the Transmit Power is lower than the Warning theshold of the IL2 Optical Module <Help> This warning indicates i… |
| 1.3.6.1.4.1.20044.36.2.2.1.33.6 | ScalarpmoailAlmClientOutputPwrHighWarning | read-only | current | IL2 Tx Pwr High Warning :This OID indicates that the Transmit Power is higher than the Warning theshold of the IL2 Optical Module <Help> This warning indicates… |
| 1.3.6.1.4.1.20044.36.2.2.1.33.7 | ScalarpmoailAlmClientBiasLowWarning | read-only | current | IL2 Bias Low Warning :This OID indicates that the Bias is lower than the Warning theshold of the IL2 Optical Module <Help> This warning indicates if the IL2 bi… |
| 1.3.6.1.4.1.20044.36.2.2.1.33.8 | ScalarpmoailAlmClientBiasHighWarning | read-only | current | IL2 Bias High Warning :This OID indicates that the Bias is higher than the Warning theshold of the IL2 Optical Module <Help> This warning indicates if the IL2 … |
| 1.3.6.1.4.1.20044.36.2.2.2 | NodepmoailAlmClientUrg | |||
| 1.3.6.1.4.1.20044.36.2.2.2.32 | NodepmoailAlmclientEdfaAlarms1 | |||
| 1.3.6.1.4.1.20044.36.2.2.2.32.1 | ScalarpmoailAlmClientGainLowAlarm | read-only | current | IL2 Gain Low Alarm :This OID indicates that the Gain is lower than the alarm theshold of the IL2 Module <Help> This alarm indicates if the IL2 gain is too low … |
| 1.3.6.1.4.1.20044.36.2.2.2.32.2 | ScalarpmoailAlmClientGainHighAlarm | read-only | current | IL2 Gain High Alarm :This OID indicates that the Gain is higher than the alarm threshold of the IL2 Module <Help> This alarm indicates if the IL2 gain is too h… |
| 1.3.6.1.4.1.20044.36.2.2.2.32.3 | ScalarpmoailAlmClientInputPwrLowAlarm | read-only | current | IL1 Rx Pwr Low Alarm :This OID indicates that the Receive Power is lower than the alarm theshold of the IL1 Optical Module <Help> This alarm indicates if the I… |
| 1.3.6.1.4.1.20044.36.2.2.2.32.4 | ScalarpmoailAlmClientInputPwrHighAlarm | read-only | current | IL1 Rx Pwr High Alarm :This OID indicates that the Receive Power is higher than the alarm theshold of the IL1 Optical Module <Help> This alarm indicates if the… |
| 1.3.6.1.4.1.20044.36.2.2.2.32.5 | ScalarpmoailAlmClientOutputPwrLowAlarm | read-only | current | IL2 Tx Pwr Low Alarm :This OID indicates that the Transmit Power is lower than the alarm theshold of the IL2 Optical Module <Help> This alarm indicates if the … |
| 1.3.6.1.4.1.20044.36.2.2.2.32.6 | ScalarpmoailAlmClientOutputPwrHighAlarm | read-only | current | IL2 Tx Pwr High Alarm :This OID indicates that the Transmit Power is higher than the alarm theshold of the IL2 Optical Module <Help> This alarm indicates if th… |
| 1.3.6.1.4.1.20044.36.2.2.2.32.7 | ScalarpmoailAlmClientBiasLowAlarm | read-only | current | IL2 Bias Low Alarm :This OID indicates that the Bias is lower than the alarm theshold of the IL2 Optical Module <Help> This alarm indicates if the IL2 bias is … |
| 1.3.6.1.4.1.20044.36.2.2.2.32.8 | ScalarpmoailAlmClientBiasHighAlarm | read-only | current | IL2 Bias High Alarm :This OID indicates that the Bias is higher than the alarm theshold of the IL2 Optical Module <Help> This alarm indicates if the IL2 bias i… |
| 1.3.6.1.4.1.20044.36.2.2.3 | NodepmoailAlmClientCrit | |||
| 1.3.6.1.4.1.20044.36.2.2.3.8 | NodepmoailAlmsynthAlm8 | |||
| 1.3.6.1.4.1.20044.36.2.2.3.8.4 | ScalarpmoailAlmClientHwFail | read-only | current | Client Port HW Failure :This OID indicates a failure on Client port, most probably caused by a HW issue <Condtype> CLIENT_HW_FAIL <Probcause> equipmentMalfunct… |
| 1.3.6.1.4.1.20044.36.2.2.3.8.5 | ScalarpmoailAlmClientTxOff | read-only | current | IL2 Optical Output Shutdown :This OID indicates the IL2 optical output power is on <Help> This status indicates if the IL2 laser pump transceiver laser is ON o… |
| 1.3.6.1.4.1.20044.36.2.2.3.8.9 | ScalarpmoailAlmClientDdmWarning | read-only | current | Warning On Client Optical Module DDM :This OID indicates a warning is present coming out of Client optical interface DDM <Condtype> CLIENT_DDM_WARNING <Probcau… |
| 1.3.6.1.4.1.20044.36.2.2.3.8.10 | ScalarpmoailAlmClientDdmAlm | read-only | current | Alarm On Client Optical Module DDM :This OID indicates an alarm is present coming out of Client optical interface DDM <Condtype> CLIENT_DDM_ALM <Probcause> equ… |
| 1.3.6.1.4.1.20044.36.2.2.3.8.12 | ScalarpmoailAlmClientFail | read-only | current | Client Port Failure :This OID indicates a failure on the Client port <Condtype> CLIENT_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (1… |
| 1.3.6.1.4.1.20044.36.2.2.3.35 | NodepmoailAlmclientEdfaAlarms2 | |||
| 1.3.6.1.4.1.20044.36.2.2.3.35.1 | ScalarpmoailAlmClientEdfaNr | read-only | current | IL2 Optical Module Not Ready :This OID indicates that the IL2 Optical Module is not ready <Help> This status indicates if the IL2 has been correctly initialize… |
| 1.3.6.1.4.1.20044.36.2.2.3.35.2 | ScalarpmoailAlmClientEdfaTecFail | read-only | current | IL2 TEC Fail :This OID indicates that the TEC is in fail condition on the IL2 Optical Module <Help> This alarm indicates if the TEC of the IL2 is in fail condi… |
| 1.3.6.1.4.1.20044.36.2.2.3.35.3 | ScalarpmoailAlmClientEdfaLaserFail | read-only | current | IL2 Pump Laser Fail :This OID indicates a Transmit Laser Fail on the IL2 Optical Module <Help> This alarm indicates if the laser of the IL2 is in fail conditio… |
| 1.3.6.1.4.1.20044.36.2.2.3.35.4 | ScalarpmoailAlmClientEdfaLos | read-only | current | IL1 Loss Of Signal :This OID indicates a Loss of Signal on the IL1 Optical Module <Help> This alarm indicates if an optical signal is detected on the IL1 input… |
| 1.3.6.1.4.1.20044.36.2.2.3.35.5 | ScalarpmoailAlmClientExtPumpEdfaLowCurrent | read-only | current | IL2 External Pump1 Low Current :This OID indicates that the EDFA pump current of the first external pump linked to the IL2 is too low <Help> This alarm indicat… |
| 1.3.6.1.4.1.20044.36.2.3 | NodepmoailAlmLine | |||
| 1.3.6.1.4.1.20044.36.2.3.1 | NodepmoailAlmLineNurg | |||
| 1.3.6.1.4.1.20044.36.2.3.1.41 | NodepmoailAlmlineEdfaWarnings | |||
| 1.3.6.1.4.1.20044.36.2.3.1.41.1 | ScalarpmoailAlmLineGainLowWarning | read-only | current | IL1 Gain Low Warning :This OID indicates that the Gain is lower than the Warning theshold of the IL1 Module <Help> This alarm indicates if the IL1 gain is too … |
| 1.3.6.1.4.1.20044.36.2.3.1.41.2 | ScalarpmoailAlmLineGainHighWarning | read-only | current | IL1 Gain High Warning :This OID indicates that the Gain is higher than the Warning threshold of the IL1 Module <Help> This alarm indicates if the IL1 gain is t… |
| 1.3.6.1.4.1.20044.36.2.3.1.41.3 | ScalarpmoailAlmLineInputPwrLowWarning | read-only | current | IL2 Rx Pwr Low Warning :This OID indicates that the Receive Power is lower than the Warning theshold of the IL2 Optical Module <Help> This warning indicates if… |
| 1.3.6.1.4.1.20044.36.2.3.1.41.4 | ScalarpmoailAlmLineInputPwrHighWarning | read-only | current | IL2 Rx Pwr High Warning :This OID indicates that the Receive Power is higher than the Warning theshold of the IL2 Optical Module <Help> This warning indicates … |
| 1.3.6.1.4.1.20044.36.2.3.1.41.5 | ScalarpmoailAlmLineOutputPwrLowWarning | read-only | current | IL1 Tx Pwr Low Warning :This OID indicates that the Transmit Power is lower than the Warning theshold of the IL1 Optical Module <Help> This warning indicates i… |
| 1.3.6.1.4.1.20044.36.2.3.1.41.6 | ScalarpmoailAlmLineOutputPwrHighWarning | read-only | current | IL1 Tx Pwr High Warning :This OID indicates that the Transmit Power is higher than the Warning theshold of the IL1 Optical Module <Help> This warning indicates… |
| 1.3.6.1.4.1.20044.36.2.3.1.41.7 | ScalarpmoailAlmLineBiasLowWarning | read-only | current | IL1 Bias Low Warning :This OID indicates that the Bias is lower than the Warning theshold of the IL1 Optical Module <Help> This warning indicates if the IL1 bi… |
| 1.3.6.1.4.1.20044.36.2.3.1.41.8 | ScalarpmoailAlmLineBiasHighWarning | read-only | current | IL1 Bias High Warning :This OID indicates that the Bias is higher than the Warning theshold of the IL1 Optical Module <Help> This warning indicates if the IL1 … |
| 1.3.6.1.4.1.20044.36.2.3.2 | NodepmoailAlmLineUrg | |||
| 1.3.6.1.4.1.20044.36.2.3.2.40 | NodepmoailAlmlineEdfaAlarms1 | |||
| 1.3.6.1.4.1.20044.36.2.3.2.40.1 | ScalarpmoailAlmLineGainLowAlarm | read-only | current | IL1 Gain Low Alarm :This OID indicates that the Gain is lower than the alarm theshold of the IL1 Module <Help> This alarm indicates if the IL1 gain is too low … |
| 1.3.6.1.4.1.20044.36.2.3.2.40.2 | ScalarpmoailAlmLineGainHighAlarm | read-only | current | IL1 Gain High Alarm :This OID indicates that the Gain is higher than the alarm threshold of the IL1 Module <Help> This alarm indicates if the IL1 gain is too h… |
| 1.3.6.1.4.1.20044.36.2.3.2.40.3 | ScalarpmoailAlmLineInputPwrLowAlarm | read-only | current | IL2 Rx Pwr Low Alarm :This OID indicates that the Receive Power is lower than the alarm theshold of the IL2 Optical Module <Help> This alarm indicates if the I… |
| 1.3.6.1.4.1.20044.36.2.3.2.40.4 | ScalarpmoailAlmLineInputPwrHighAlarm | read-only | current | IL2 Rx Pwr High Alarm :This OID indicates that the Receive Power is higher than the alarm theshold of the IL2 Optical Module <Help> This alarm indicates if the… |
| 1.3.6.1.4.1.20044.36.2.3.2.40.5 | ScalarpmoailAlmLineOutputPwrLowAlarm | read-only | current | IL1 Tx Pwr Low Alarm :This OID indicates that the Transmit Power is lower than the alarm theshold of the IL1 Optical Module <Help> This alarm indicates if the … |
| 1.3.6.1.4.1.20044.36.2.3.2.40.6 | ScalarpmoailAlmLineOutputPwrHighAlarm | read-only | current | IL1 Tx Pwr High Alarm :This OID indicates that the Transmit Power is higher than the alarm theshold of the IL1 Optical Module <Help> This alarm indicates if th… |
| 1.3.6.1.4.1.20044.36.2.3.2.40.7 | ScalarpmoailAlmLineBiasLowAlarm | read-only | current | IL1 Bias Low Alarm :This OID indicates that the Bias is lower than the alarm theshold of the IL1 Optical Module <Help> This alarm indicates if the IL1 bias is … |
| 1.3.6.1.4.1.20044.36.2.3.2.40.8 | ScalarpmoailAlmLineBiasHighAlarm | read-only | current | IL1 Bias High Alarm :This OID indicates that the Bias is higher than the alarm theshold of the IL1 Optical Module <Help> This alarm indicates if the IL1 bias i… |
| 1.3.6.1.4.1.20044.36.2.3.3 | NodepmoailAlmLineCrit | |||
| 1.3.6.1.4.1.20044.36.2.3.3.7 | NodepmoailAlmsynthAlm7 | |||
| 1.3.6.1.4.1.20044.36.2.3.3.7.4 | ScalarpmoailAlmLineHwFail | read-only | current | Line Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Condtype> LINE_HW_FAIL <Probcause> equipmentMalfunction (1… |
| 1.3.6.1.4.1.20044.36.2.3.3.7.5 | ScalarpmoailAlmLineTxOff | read-only | current | IL1 Optical Output Shutdown :This OID indicates the IL1 optical output power is on <Help> This status indicates if the IL1 laser pump is ON or OFF <Condtype> L… |
| 1.3.6.1.4.1.20044.36.2.3.3.7.9 | ScalarpmoailAlmLineDdmWarning | read-only | current | Warning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line optical interface DDM <Condtype> LINE_DDM_WARNING <Probcause> eq… |
| 1.3.6.1.4.1.20044.36.2.3.3.7.10 | ScalarpmoailAlmLineDdmAlm | read-only | current | Alarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line optical interface DDM <Condtype> LINE_DDM_ALM <Probcause> equipment… |
| 1.3.6.1.4.1.20044.36.2.3.3.7.12 | ScalarpmoailAlmLineFail | read-only | current | Line Port Failure :This OID indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12) <Po… |
| 1.3.6.1.4.1.20044.36.2.3.3.43 | NodepmoailAlmlineEdfaAlarms2 | |||
| 1.3.6.1.4.1.20044.36.2.3.3.43.1 | ScalarpmoailAlmLineEdfaNr | read-only | current | IL1 Optical Module Not Ready :This OID indicates that the IL1 Optical Module is not ready <Help> This status indicates if the IL1 has been correctly initialize… |
| 1.3.6.1.4.1.20044.36.2.3.3.43.2 | ScalarpmoailAlmLineEdfaTecFail | read-only | current | IL1 TEC Fail :This OID indicates that the TEC is in fail condition on the IL1 Optical Module <Help> This alarm indicates if the TEC of the IL1 is in fail condi… |
| 1.3.6.1.4.1.20044.36.2.3.3.43.3 | ScalarpmoailAlmLineEdfaLaserFail | read-only | current | IL1 Pump Laser Fail :This OID indicates a Transmit Laser Fail on the IL1 Optical Module <Help> This alarm indicates if the laser of the IL1 is in fail conditio… |
| 1.3.6.1.4.1.20044.36.2.3.3.43.4 | ScalarpmoailAlmLineEdfaLos | read-only | current | IL2 Loss Of Signal :This OID indicates a Loss of Signal on the IL2 Optical Module <Help> This alarm indicates if an optical signal is detected on the IL2 input… |
| 1.3.6.1.4.1.20044.36.2.3.3.43.5 | ScalarpmoailAlmLineExtPumpEdfaLowCurrent | read-only | current | IL1 External Pump1 Low Current :This OID indicates that the EDFA pump current of the first external pump linked to the IL1 is too low <Help> This alarm indicat… |
| 1.3.6.1.4.1.20044.36.3 | Nodepmoailmeasures | |||
| 1.3.6.1.4.1.20044.36.3.1 | NodepmoailMesrOther | |||
| 1.3.6.1.4.1.20044.36.3.1.72 | ScalarpmoailMesrtempMeas | read-only | current | Module Temperature :This OID gives the temperature of the PM (Unit = C) <Help> This measure gives the temperature of the module |
| 1.3.6.1.4.1.20044.36.3.1.73 | ScalarpmoailMesr3v3Meas | read-only | current | Module 3.3 Voltage :This OID gives the 3V3 voltage of the PM (Unit = V) <Help> This measure gives the 3V3 voltage of the module |
| 1.3.6.1.4.1.20044.36.3.2 | NodepmoailMesrClient | |||
| 1.3.6.1.4.1.20044.36.3.2.32 | ScalarpmoailMesrclientEdfaBiasMeas | read-only | current | IL2 Pump Laser Current :This OID gives the pump laser current of the IL2 Optical Module (Current =AV/100) (Unit = mA) <Help> This measure gives the bias of the… |
| 1.3.6.1.4.1.20044.36.3.2.33 | ScalarpmoailMesrclientEdfaTxpwrMeas | read-only | current | IL2 Tx Power :This OID gives the transmit power value of the IL2 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Tx optical… |
| 1.3.6.1.4.1.20044.36.3.2.34 | ScalarpmoailMesrclientEdfaRxpwrMeas | read-only | current | IL1 Rx Power :This OID gives the receive power value of the IL1 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Rx optical … |
| 1.3.6.1.4.1.20044.36.3.2.35 | ScalarpmoailMesrclientEdfaGainMeas | read-only | current | IL2 Gain :This OID gives the gain value of the IL2 Module (Gain =(AV-32768)*0,005) (Unit = dB) <Help> This measure gives the optical gain of the IL2 |
| 1.3.6.1.4.1.20044.36.3.3 | NodepmoailMesrLine | |||
| 1.3.6.1.4.1.20044.36.3.3.40 | ScalarpmoailMesrlineEdfaBiasMeas | read-only | current | IL1 Pump Laser Current :This OID gives the pump laser current of the IL1 Optical Module (Current =AV/100) (Unit = mA) <Help> This measure gives the bias of the… |
| 1.3.6.1.4.1.20044.36.3.3.41 | ScalarpmoailMesrlineEdfaTxpwrMeas | read-only | current | IL1 Tx Power :This OID gives the transmit power value of the IL1 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Tx optical… |
| 1.3.6.1.4.1.20044.36.3.3.42 | ScalarpmoailMesrlineEdfaRxpwrMeas | read-only | current | IL2 Rx Power :This OID gives the receive power value of the IL2 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Rx optical … |
| 1.3.6.1.4.1.20044.36.3.3.43 | ScalarpmoailMesrlineEdfaGainMeas | read-only | current | IL1 Gain :This OID gives the gain value of the IL1 Module (Gain =(AV-32768)*0,005) (Unit = dB) <Help> This measure gives the optical gain of the IL1 |
| 1.3.6.1.4.1.20044.36.6 | NodepmoailcontrolsWrite | |||
| 1.3.6.1.4.1.20044.36.6.1 | NodepmoailCtrlOther | |||
| 1.3.6.1.4.1.20044.36.6.1.0 | NodepmoailCtrlsynth0 | |||
| 1.3.6.1.4.1.20044.36.6.1.0.1 | ScalarpmoailCtrlConfLoad | read-write | current | Load Configuration Tables :When set this enables loading from flash configuration1 into the module. |
| 1.3.6.1.4.1.20044.36.6.1.0.9 | ScalarpmoailCtrlConfFlash | read-write | current | Write Configuration Tables :This bit saves the current configuration of the module as configuration in the flash. <Help> This control saves the customer config… |
| 1.3.6.1.4.1.20044.36.6.1.0.13 | ScalarpmoailCtrlConfClear | read-write | current | Clear Configuration Tables :This bit clears the configuration tables from configuration in the flash. <Help> This control restores the default configuration of… |
| 1.3.6.1.4.1.20044.36.6.1.5 | NodepmoailCtrlswMgnt | |||
| 1.3.6.1.4.1.20044.36.6.1.5.2 | ScalarpmoailCtrlColdReset | read-write | current | PM Cold Reset :This OID, when set, causes a cold reset of the Software. This reset is traffic affecting, and the configuration of Software is reloaded on start… |
| 1.3.6.1.4.1.20044.36.6.1.5.3 | ScalarpmoailCtrlWarmReset | read-write | current | PM Warm Reset :This OID, when set, causes a warm reset of the Software. This reset is not traffic affecting, and the configuration of the Sofwtare remains unch… |
| 1.3.6.1.4.1.20044.36.6.1.72 | NodepmoailCtrlpowerDown | |||
| 1.3.6.1.4.1.20044.36.6.1.72.1 | ScalarpmoailCtrlSoftPowerDown | read-write | current | Module Software Shutdown :This OID shuts down the PM Software <Help> This control initiates a shut down of software. |
| 1.3.6.1.4.1.20044.36.6.1.73 | NodepmoailCtrlledTest | |||
| 1.3.6.1.4.1.20044.36.6.1.73.1 | ScalarpmoailCtrlGreenLed | read-write | current | Green Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green |
| 1.3.6.1.4.1.20044.36.6.1.73.2 | ScalarpmoailCtrlRedLed | read-write | current | Red Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red |
| 1.3.6.1.4.1.20044.36.6.1.73.3 | ScalarpmoailCtrlLedOff | read-write | current | Leds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF |
| 1.3.6.1.4.1.20044.36.6.1.75 | NodepmoailCtrlmaintMode | |||
| 1.3.6.1.4.1.20044.36.6.1.75.1 | ScalarpmoailCtrlMaintenance | read-write | current | Module Maintenance Mode :This OID sets the PM in maintenance mode <Help> This control enables the maintenance mode of the module |
| 1.3.6.1.4.1.20044.36.6.2 | NodepmoailCtrlClient | |||
| 1.3.6.1.4.1.20044.36.6.2.32 | NodepmoailCtrlclientEdfaLaserOff | |||
| 1.3.6.1.4.1.20044.36.6.2.32.1 | ScalarpmoailCtrlClientEdfaLaserOff | read-write | current | IL2 Pump Laser Shutdown :This OID switches OFF the laser of the IL2 Optical Module <Help> This control defines the laser state of the IL2 |
| 1.3.6.1.4.1.20044.36.6.2.33 | ScalarpmoailCtrlclientEdfaMode | read-write | current | IL2 Module Mode :This OID selects the mode of the IL2 Module <Help> This control defines the IL2 Mode (0: Default mode, 2:Constant output power) |
| 1.3.6.1.4.1.20044.36.6.2.34 | ScalarpmoailCtrlclientIlasSettingValue | read-write | current | IL2 Laser Current Value :This OID sets the value of the laser current of the IL2 Module (active only in constant current mode) (AV = Current *100) (Unit = mA) … |
| 1.3.6.1.4.1.20044.36.6.2.35 | ScalarpmoailCtrlclientPlasSettingValue | read-write | current | IL2 Pump Power Value :This OID sets the value of the laser power of the IL2 Optical Module (active only in constant power mode) (AV=(Power/0,005) + 32768) (Uni… |
| 1.3.6.1.4.1.20044.36.6.2.36 | ScalarpmoailCtrlclientGainSettingValue | read-write | current | IL2 Gain Value :This OID sets the value of the gain of the IL2 Module (active only in constant gain mode) (AV=(Gain/0,005) + 32768) (Unit = dB) |
| 1.3.6.1.4.1.20044.36.6.2.37 | ScalarpmoailCtrlclientEffPwrOutSettingValue | read-write | current | IL2 Effective Output Power :This OID sets the value of the effective output power (without noise power) of the IL2 Module (active only in input power function … |
| 1.3.6.1.4.1.20044.36.6.3 | NodepmoailCtrlLine | |||
| 1.3.6.1.4.1.20044.36.6.3.40 | NodepmoailCtrllineEdfaLaserOff | |||
| 1.3.6.1.4.1.20044.36.6.3.40.1 | ScalarpmoailCtrlLineEdfaLaserOff | read-write | current | IL1 Pump Laser Shutdown :This OID switches OFF the laser of the IL1 Optical Module <Help> This control defines the laser state of the IL1 |
| 1.3.6.1.4.1.20044.36.6.3.41 | ScalarpmoailCtrllineEdfaMode | read-write | current | IL1 Module Mode :This OID selects the mode of the IL1 Module <Help> This control defines the IL1 Mode (0: Default mode, 2:Constant output power) |
| 1.3.6.1.4.1.20044.36.6.3.42 | ScalarpmoailCtrllineIlasSettingValue | read-write | current | IL1 Laser Current Value :This OID sets the value of the laser current of the IL1 Module (active only in constant current mode) (AV = Current *100) (Unit = mA) … |
| 1.3.6.1.4.1.20044.36.6.3.43 | ScalarpmoailCtrllinePlasSettingValue | read-write | current | IL1 Pump Power Value :This OID sets the value of the laser power of the IL1 Optical Module (active only in constant power mode) (AV=(Power/0,005) + 32768) (Uni… |
| 1.3.6.1.4.1.20044.36.6.3.44 | ScalarpmoailCtrllineGainSettingValue | read-write | current | IL1 Gain Value :This OID sets the value of the gain of the IL1 Module (active only in constant gain mode) (AV=(Gain/0,005) + 32768) (Unit = dB) |
| 1.3.6.1.4.1.20044.36.6.3.45 | ScalarpmoailCtrllineEffPwrOutSettingValue | read-write | current | IL1 Effective Output Power :This OID sets the value of the effective output power (without noise power) of the IL1 Module (active only in input power function … |
| 1.3.6.1.4.1.20044.36.7 | Nodepmoailri | |||
| 1.3.6.1.4.1.20044.36.7.2 | ScalarpmoailRinvReloadInventory | read-write | current | Reload the inventory: This OID triggers an inventory reload. |
| 1.3.6.1.4.1.20044.36.7.3 | ScalarpmoailRinvModulePlatform | read-only | current | Module platform description: This OID contains the description of the Module. |
| 1.3.6.1.4.1.20044.36.7.4 | ScalarpmoailRinvSwPlatform | read-only | current | SW platform description: This OID contains the description of the Software platform. |
| 1.3.6.1.4.1.20044.36.7.5 | ScalarpmoailRinvSwFoa | read-only | current | Optical device driver description: This OID contains the description of the driver of the optical devices (Booster and Pre-Amp) |
| 1.3.6.1.4.1.20044.36.7.6 | TablepmoailRinvInLine1Table | not-accessible | current | List of the InLine1s on the selected module |
| 1.3.6.1.4.1.20044.36.7.6.1 | RowpmoailRinvInLine1Entry | not-accessible | current | Row definition for the InLine1s table |
| 1.3.6.1.4.1.20044.36.7.6.1.1 | ColumnpmoailRinvInLine1Index | read-only | current | Index for InLine1 table |
| 1.3.6.1.4.1.20044.36.7.6.1.2 | ColumnpmoailRinvInLine1 | read-only | current | Inventory for the InLine1: This OID contains the inventory for the InLine1 |
| 1.3.6.1.4.1.20044.36.7.7 | TablepmoailRinvInLine2Table | not-accessible | current | List of the InLine2s on the selected module |
| 1.3.6.1.4.1.20044.36.7.7.1 | RowpmoailRinvInLine2Entry | not-accessible | current | Row definition for the InLine2 table |
| 1.3.6.1.4.1.20044.36.7.7.1.1 | ColumnpmoailRinvInLine2Index | read-only | current | Index for InLine2 table |
| 1.3.6.1.4.1.20044.36.7.7.1.2 | ColumnpmoailRinvInLine2 | read-only | current | Inventory for the InLine2: This OID contains the inventory for the InLine2 |
| 1.3.6.1.4.1.20044.36.9 | NodepmoailConfig | |||
| 1.3.6.1.4.1.20044.36.9.1 | NodepmoailCfgNoValue | |||
| 1.3.6.1.4.1.20044.36.9.1.1 | NodepmoailtableclientStartup | |||
| 1.3.6.1.4.1.20044.36.9.1.1.2 | ScalarpmoailCfgclientEdfaLaserCtrl | read-write | current | Default Settings on Client Laser :This OID configures the default initialisation settings on the client laser. |
| 1.3.6.1.4.1.20044.36.9.1.1.3 | ScalarpmoailCfgclientEdfaLaserMode | read-write | current | Default Settings on Client mode :This OID configures the default mode on the client amplifier. |
| 1.3.6.1.4.1.20044.36.9.2 | NodepmoailCfgLineStartUp | |||
| 1.3.6.1.4.1.20044.36.9.2.1 | NodepmoailtablelineStartup | |||
| 1.3.6.1.4.1.20044.36.9.2.1.2 | ScalarpmoailCfglineEdfaLaserCtrl | read-write | current | Default Settings on Line Laser :This OID configures the default initialisation settings on the line laser. |
| 1.3.6.1.4.1.20044.36.9.2.1.3 | ScalarpmoailCfglineEdfaLaserMode | read-write | current | Default Settings on Line mode :This OID configures the default mode on the line amplifier. |
| 1.3.6.1.4.1.20044.36.9.3 | NodepmoailCfgLabels | |||
| 1.3.6.1.4.1.20044.36.9.3.1 | TablepmoailCfgLabelclientTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.36.9.3.1.1 | RowpmoailCfgLabelclientEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.36.9.3.1.1.1 | ColumnpmoailCfgLabelclientIndex | read-only | current | Index definition for the labelclient table |
| 1.3.6.1.4.1.20044.36.9.3.1.1.3 | ColumnpmoailCfgLabelclientPortn | read-write | current | Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. |
| 1.3.6.1.4.1.20044.36.9.3.2 | TablepmoailCfgLabellineTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.36.9.3.2.1 | RowpmoailCfgLabellineEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.36.9.3.2.1.1 | ColumnpmoailCfgLabellineIndex | read-only | current | Index definition for the labelline table |
| 1.3.6.1.4.1.20044.36.9.3.2.1.3 | ColumnpmoailCfgLabellinePortn | read-write | current | Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. |
| 1.3.6.1.4.1.20044.36.9.257 | ScalarpmoailCfgWriteConfiguration | read-write | current | Write configuration to module:This OID writes the complete configuration to the module |
| 1.3.6.1.4.1.20044.36.10 | Nodepmoailtraps | |||
| 1.3.6.1.4.1.20044.36.10.4 | ScalarpmoailtrapBoardNumber | read-only | current | Last module which generates a trap |
| 1.3.6.1.4.1.20044.36.10.30 | NotificationpmoailLineTrapNotUrgentGoesOn | current | Not urgent Line default is activated | |
| 1.3.6.1.4.1.20044.36.10.31 | NotificationpmoailLineTrapNotUrgentGoesOff | current | Not urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.36.10.32 | NotificationpmoailLineTrapUrgentGoesOn | current | Urgent Line default is activated | |
| 1.3.6.1.4.1.20044.36.10.33 | NotificationpmoailLineTrapUrgentGoesOff | current | Urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.36.10.34 | NotificationpmoailLineTrapCritGoesOn | current | Critical Line default is activated | |
| 1.3.6.1.4.1.20044.36.10.35 | NotificationpmoailLineTrapCritGoesOff | current | Critical Line default disappeared | |
| 1.3.6.1.4.1.20044.36.10.40 | NotificationpmoailClientTrapNotUrgentGoesOn | current | Not urgent client default is activated | |
| 1.3.6.1.4.1.20044.36.10.41 | NotificationpmoailClientTrapNotUrgentGoesOff | current | Not urgent client default disappeared | |
| 1.3.6.1.4.1.20044.36.10.42 | NotificationpmoailClientTrapUrgentGoesOn | current | Urgent client default is activated | |
| 1.3.6.1.4.1.20044.36.10.43 | NotificationpmoailClientTrapUrgentGoesOff | current | Urgent client default disappeared | |
| 1.3.6.1.4.1.20044.36.10.44 | NotificationpmoailClientTrapCritGoesOn | current | Critical client default is activated | |
| 1.3.6.1.4.1.20044.36.10.45 | NotificationpmoailClientTrapCritGoesOff | current | Critical client default disappeared | |
| 1.3.6.1.4.1.20044.36.10.50 | NotificationpmoailPowerTrapUrgentGoesOn | current | Urgent power supply default is activated | |
| 1.3.6.1.4.1.20044.36.10.51 | NotificationpmoailPowerTrapUrgentGoesOff | current | Urgent power supply default disappeared |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| PmoailboosterMode | INTEGER { oaboosterdefaultmode(0), oaboosterconstantcurrentmode(1), oaboosterconstantpowermode(2) } | current | Different modes on OA booster |
| PmoailpreampMode | INTEGER { oapreampdefaultmode(0), oapreampconstantcurrentmode(1), oapreampconstantpowermode(2) } | current | Different modes on OA preamp |