EKINOPS-PmOailhc-MIB
214 objects
Creation
Imported Objects
| EKINOPS-MIB | EkiApiState EkiMeasureType EkiMode ekinops EkiOnOff EkiProtocol EkiState EkiSynchroMode |
| SNMPv2-SMI | Counter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20044.55 | Identitymodulepmoailhc | Creation | ||
| 1.3.6.1.4.1.20044.55.2 | Nodepmoailhcalarms | |||
| 1.3.6.1.4.1.20044.55.2.1 | NodepmoailhcAlmOther | |||
| 1.3.6.1.4.1.20044.55.2.1.1 | NodepmoailhcAlmOtherNurg | |||
| 1.3.6.1.4.1.20044.55.2.1.1.2 | NodepmoailhcAlmsynthAlm2 | |||
| 1.3.6.1.4.1.20044.55.2.1.1.2.1 | ScalarpmoailhcAlmConfTableSave | read-only | current | PM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> bandw… |
| 1.3.6.1.4.1.20044.55.2.1.1.2.2 | ScalarpmoailhcAlmInvUpload | read-only | current | Inventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> bandwidthReduced(4) <Alarmtype> other (1… |
| 1.3.6.1.4.1.20044.55.2.1.1.2.3 | ScalarpmoailhcAlmConfTableLoad | read-only | current | PM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> bandwidthReduced(… |
| 1.3.6.1.4.1.20044.55.2.1.1.75 | NodepmoailhcAlmfoaWarnings | |||
| 1.3.6.1.4.1.20044.55.2.1.1.75.7 | ScalarpmoailhcAlmTermpLowWarning | read-only | current | Temperature Low Warning :This OID indicates that the PM temperature if lower than the Warning threshold <Condtype> TERMP_LOW_WARNING <Probcause> temperatureUna… |
| 1.3.6.1.4.1.20044.55.2.1.1.75.8 | ScalarpmoailhcAlmTempHighWarning | read-only | current | Temperature High Warning :This OID indicates that the PM temperature if higher than the Warning threshold <Condtype> TEMP_HIGH_WARNING <Probcause> temperatureU… |
| 1.3.6.1.4.1.20044.55.2.1.2 | NodepmoailhcAlmOtherUrg | |||
| 1.3.6.1.4.1.20044.55.2.1.2.74 | NodepmoailhcAlmfoaAlarms | |||
| 1.3.6.1.4.1.20044.55.2.1.2.74.7 | ScalarpmoailhcAlmTermpLowAlarm | read-only | current | Temperature Low Alarm :This OID indicates that the PM temperature if lower than the alarm threshold <Condtype> TERMP_LOW_ALARM <Probcause> temperatureUnaccepta… |
| 1.3.6.1.4.1.20044.55.2.1.2.74.8 | ScalarpmoailhcAlmTempHighAlarm | read-only | current | Temperature High Alarm :This OID indicates that the PM temperature is higher than the alarm threshold <Condtype> TEMP_HIGH_ALARM <Probcause> temperatureUnaccep… |
| 1.3.6.1.4.1.20044.55.2.1.3 | NodepmoailhcAlmOtherCrit | |||
| 1.3.6.1.4.1.20044.55.2.1.3.0 | NodepmoailhcAlmsynthAlm0 | |||
| 1.3.6.1.4.1.20044.55.2.1.3.0.1 | ScalarpmoailhcAlmMaintenanceMode | read-only | current | Maintenance Mode :This OID indicates that the PM is in maintenance mode <Help> This status indiates if the module is currently in maintenance mode <Condtype> M… |
| 1.3.6.1.4.1.20044.55.2.1.3.0.2 | ScalarpmoailhcAlmAprOn | read-only | current | Automatic Power Reduction :This OID indicates that the APR algorithm has been operated and the output of the lasers are shutdown <Help> The APR algorithm has b… |
| 1.3.6.1.4.1.20044.55.2.1.3.0.9 | ScalarpmoailhcAlmModGlobFail | read-only | current | Module Failure :This OID is set on detection of a failure originating from the PM <Condtype> MOD_GLOB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> sy… |
| 1.3.6.1.4.1.20044.55.2.1.3.0.10 | ScalarpmoailhcAlmUpEdfaInitNotCompl | read-only | current | IL1 Not Initialized :This OID indicates that the initialisation of the IL1 is not completed <Help> This status indicates if the IL1 has been correctly initiali… |
| 1.3.6.1.4.1.20044.55.2.1.3.0.11 | ScalarpmoailhcAlmDwEdfaInitNotCompl | read-only | current | IL2 Not Initialized :This OID indicates that the initialisation of the IL2 is not completed <Help> This status indicates if the IL2 has been correctly initiali… |
| 1.3.6.1.4.1.20044.55.2.1.3.0.12 | ScalarpmoailhcAlmExtPump1NotLocked | read-only | current | External Pump1 Not Detected :This OID indicates that the first external pump is not detected by the amplifier module <Help> This alarm indicates if the first e… |
| 1.3.6.1.4.1.20044.55.2.1.3.0.13 | ScalarpmoailhcAlmExtPump2NotLocked | read-only | current | External Pump2 Not Detected :This OID indicates that the second external pump is not detected by the amplifier module <Help> This alarm indicates if the second… |
| 1.3.6.1.4.1.20044.55.2.1.3.0.15 | ScalarpmoailhcAlmDefFuseA | read-only | current | Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.55.2.1.3.0.16 | ScalarpmoailhcAlmDefFuseB | read-only | current | Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.55.2.2 | NodepmoailhcAlmClient | |||
| 1.3.6.1.4.1.20044.55.2.2.1 | NodepmoailhcAlmClientNurg | |||
| 1.3.6.1.4.1.20044.55.2.2.1.33 | NodepmoailhcAlmclientEdfaWarnings | |||
| 1.3.6.1.4.1.20044.55.2.2.1.33.1 | ScalarpmoailhcAlmClientGainLowWarning | read-only | current | IL2 Gain Low Warning :This OID indicates that the Gain is lower than the Warning theshold of the IL2 Module <Help> This alarm indicates if the IL2 gain is too … |
| 1.3.6.1.4.1.20044.55.2.2.1.33.2 | ScalarpmoailhcAlmClientGainHighWarning | read-only | current | IL2 Gain High Warning :This OID indicates that the Gain is higher than the Warning threshold of the IL2 Module <Help> This alarm indicates if the IL2 gain is t… |
| 1.3.6.1.4.1.20044.55.2.2.1.33.3 | ScalarpmoailhcAlmClientInputPwrLowWarning | read-only | current | IL1 Rx Pwr Low Warning :This OID indicates that the Receive Power is lower than the Warning theshold of the IL1 Optical Module <Help> This warning indicates if… |
| 1.3.6.1.4.1.20044.55.2.2.1.33.4 | ScalarpmoailhcAlmClientInputPwrHighWarning | read-only | current | IL1 Rx Pwr High Warning :This OID indicates that the Receive Power is higher than the Warning theshold of the IL1 Optical Module <Help> This warning indicates … |
| 1.3.6.1.4.1.20044.55.2.2.1.33.5 | ScalarpmoailhcAlmClientOutputPwrLowWarning | read-only | current | IL2 Tx Pwr Low Warning :This OID indicates that the Transmit Power is lower than the Warning theshold of the IL2 Optical Module <Help> This warning indicates i… |
| 1.3.6.1.4.1.20044.55.2.2.1.33.6 | ScalarpmoailhcAlmClientOutputPwrHighWarning | read-only | current | IL2 Tx Pwr High Warning :This OID indicates that the Transmit Power is higher than the Warning theshold of the IL2 Optical Module <Help> This warning indicates… |
| 1.3.6.1.4.1.20044.55.2.2.1.33.7 | ScalarpmoailhcAlmClientBiasLowWarning | read-only | current | IL2 Bias Low Warning :This OID indicates that the Bias is lower than the Warning theshold of the IL2 Optical Module <Help> This warning indicates if the IL2 bi… |
| 1.3.6.1.4.1.20044.55.2.2.1.33.8 | ScalarpmoailhcAlmClientBiasHighWarning | read-only | current | IL2 Bias High Warning :This OID indicates that the Bias is higher than the Warning theshold of the IL2 Optical Module <Help> This warning indicates if the IL2 … |
| 1.3.6.1.4.1.20044.55.2.2.2 | NodepmoailhcAlmClientUrg | |||
| 1.3.6.1.4.1.20044.55.2.2.2.32 | NodepmoailhcAlmclientEdfaAlarms1 | |||
| 1.3.6.1.4.1.20044.55.2.2.2.32.1 | ScalarpmoailhcAlmClientGainLowAlarm | read-only | current | IL2 Gain Low Alarm :This OID indicates that the Gain is lower than the alarm theshold of the IL2 Module <Help> This alarm indicates if the IL2 gain is too low … |
| 1.3.6.1.4.1.20044.55.2.2.2.32.2 | ScalarpmoailhcAlmClientGainHighAlarm | read-only | current | IL2 Gain High Alarm :This OID indicates that the Gain is higher than the alarm threshold of the IL2 Module <Help> This alarm indicates if the IL2 gain is too h… |
| 1.3.6.1.4.1.20044.55.2.2.2.32.3 | ScalarpmoailhcAlmClientInputPwrLowAlarm | read-only | current | IL1 Rx Pwr Low Alarm :This OID indicates that the Receive Power is lower than the alarm theshold of the IL1 Optical Module <Help> This alarm indicates if the I… |
| 1.3.6.1.4.1.20044.55.2.2.2.32.4 | ScalarpmoailhcAlmClientInputPwrHighAlarm | read-only | current | IL1 Rx Pwr High Alarm :This OID indicates that the Receive Power is higher than the alarm theshold of the IL1 Optical Module <Help> This alarm indicates if the… |
| 1.3.6.1.4.1.20044.55.2.2.2.32.5 | ScalarpmoailhcAlmClientOutputPwrLowAlarm | read-only | current | IL2 Tx Pwr Low Alarm :This OID indicates that the Transmit Power is lower than the alarm theshold of the IL2 Optical Module <Help> This alarm indicates if the … |
| 1.3.6.1.4.1.20044.55.2.2.2.32.6 | ScalarpmoailhcAlmClientOutputPwrHighAlarm | read-only | current | IL2 Tx Pwr High Alarm :This OID indicates that the Transmit Power is higher than the alarm theshold of the IL2 Optical Module <Help> This alarm indicates if th… |
| 1.3.6.1.4.1.20044.55.2.2.2.32.7 | ScalarpmoailhcAlmClientBiasLowAlarm | read-only | current | IL2 Bias Low Alarm :This OID indicates that the Bias is lower than the alarm theshold of the IL2 Optical Module <Help> This alarm indicates if the IL2 bias is … |
| 1.3.6.1.4.1.20044.55.2.2.2.32.8 | ScalarpmoailhcAlmClientBiasHighAlarm | read-only | current | IL2 Bias High Alarm :This OID indicates that the Bias is higher than the alarm theshold of the IL2 Optical Module <Help> This alarm indicates if the IL2 bias i… |
| 1.3.6.1.4.1.20044.55.2.2.3 | NodepmoailhcAlmClientCrit | |||
| 1.3.6.1.4.1.20044.55.2.2.3.8 | NodepmoailhcAlmsynthAlm8 | |||
| 1.3.6.1.4.1.20044.55.2.2.3.8.4 | ScalarpmoailhcAlmClientHwFail | read-only | current | Client Port HW Failure :This OID indicates a failure on Client port, most probably caused by a HW issue <Condtype> CLIENT_HW_FAIL <Probcause> equipmentMalfunct… |
| 1.3.6.1.4.1.20044.55.2.2.3.8.5 | ScalarpmoailhcAlmClientTxOff | read-only | current | IL2 Optical Output Shutdown :This OID indicates the IL2 optical output power is on <Help> This status indicates if the IL2 laser pump transceiver laser is ON o… |
| 1.3.6.1.4.1.20044.55.2.2.3.8.9 | ScalarpmoailhcAlmClientDdmWarning | read-only | current | Warning On Client Optical Module DDM :This OID indicates a warning is present coming out of Client optical interface DDM <Condtype> CLIENT_DDM_WARNING <Probcau… |
| 1.3.6.1.4.1.20044.55.2.2.3.8.10 | ScalarpmoailhcAlmClientDdmAlm | read-only | current | Alarm On Client Optical Module DDM :This OID indicates an alarm is present coming out of Client optical interface DDM <Condtype> CLIENT_DDM_ALM <Probcause> equ… |
| 1.3.6.1.4.1.20044.55.2.2.3.8.12 | ScalarpmoailhcAlmClientFail | read-only | current | Client Port Failure :This OID indicates a failure on the Client port <Condtype> CLIENT_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (1… |
| 1.3.6.1.4.1.20044.55.2.2.3.8.13 | ScalarpmoailhcAlmClientExtPumpFail | read-only | current | IL2 External Pump Fail :This OID indicates that first external pump linked to the IL2 is in fail condition <Help> This alarm indicates if the external pump lin… |
| 1.3.6.1.4.1.20044.55.2.2.3.35 | NodepmoailhcAlmclientEdfaAlarms2 | |||
| 1.3.6.1.4.1.20044.55.2.2.3.35.1 | ScalarpmoailhcAlmClientEdfaNr | read-only | current | IL2 Optical Module Not Ready :This OID indicates that the IL2 Optical Module is not ready <Help> This status indicates if the IL2 has been correctly initialize… |
| 1.3.6.1.4.1.20044.55.2.2.3.35.2 | ScalarpmoailhcAlmClientEdfaTecFail | read-only | current | IL2 TEC Fail :This OID indicates that the TEC is in fail condition on the IL2 Optical Module <Help> This alarm indicates if the TEC of the IL2 is in fail condi… |
| 1.3.6.1.4.1.20044.55.2.2.3.35.3 | ScalarpmoailhcAlmClientEdfaLaserFail | read-only | current | IL2 Pump Laser Fail :This OID indicates a Transmit Laser Fail on the IL2 Optical Module <Help> This alarm indicates if the laser of the IL2 is in fail conditio… |
| 1.3.6.1.4.1.20044.55.2.2.3.35.4 | ScalarpmoailhcAlmClientEdfaLos | read-only | current | IL1 Loss Of Signal :This OID indicates a Loss of Signal on the IL1 Optical Module <Help> This alarm indicates if an optical signal is detected on the IL1 input… |
| 1.3.6.1.4.1.20044.55.2.2.3.35.5 | ScalarpmoailhcAlmClientExtPumpEdfaLowCurrent | read-only | current | IL2 Pump Low Current :This OID indicates that the EDFA pump current of IL2 is too low because of the external pump high power<Help> This alarm (only active whe… |
| 1.3.6.1.4.1.20044.55.2.3 | NodepmoailhcAlmLine | |||
| 1.3.6.1.4.1.20044.55.2.3.1 | NodepmoailhcAlmLineNurg | |||
| 1.3.6.1.4.1.20044.55.2.3.1.41 | NodepmoailhcAlmlineEdfaWarnings | |||
| 1.3.6.1.4.1.20044.55.2.3.1.41.1 | ScalarpmoailhcAlmLineGainLowWarning | read-only | current | IL1 Gain Low Warning :This OID indicates that the Gain is lower than the Warning theshold of the IL1 Module <Help> This alarm indicates if the IL1 gain is too … |
| 1.3.6.1.4.1.20044.55.2.3.1.41.2 | ScalarpmoailhcAlmLineGainHighWarning | read-only | current | IL1 Gain High Warning :This OID indicates that the Gain is higher than the Warning threshold of the IL1 Module <Help> This alarm indicates if the IL1 gain is t… |
| 1.3.6.1.4.1.20044.55.2.3.1.41.3 | ScalarpmoailhcAlmLineInputPwrLowWarning | read-only | current | IL2 Rx Pwr Low Warning :This OID indicates that the Receive Power is lower than the Warning theshold of the IL2 Optical Module <Help> This warning indicates if… |
| 1.3.6.1.4.1.20044.55.2.3.1.41.4 | ScalarpmoailhcAlmLineInputPwrHighWarning | read-only | current | IL2 Rx Pwr High Warning :This OID indicates that the Receive Power is higher than the Warning theshold of the IL2 Optical Module <Help> This warning indicates … |
| 1.3.6.1.4.1.20044.55.2.3.1.41.5 | ScalarpmoailhcAlmLineOutputPwrLowWarning | read-only | current | IL1 Tx Pwr Low Warning :This OID indicates that the Transmit Power is lower than the Warning theshold of the IL1 Optical Module <Help> This warning indicates i… |
| 1.3.6.1.4.1.20044.55.2.3.1.41.6 | ScalarpmoailhcAlmLineOutputPwrHighWarning | read-only | current | IL1 Tx Pwr High Warning :This OID indicates that the Transmit Power is higher than the Warning theshold of the IL1 Optical Module <Help> This warning indicates… |
| 1.3.6.1.4.1.20044.55.2.3.1.41.7 | ScalarpmoailhcAlmLineBiasLowWarning | read-only | current | IL1 Bias Low Warning :This OID indicates that the Bias is lower than the Warning theshold of the IL1 Optical Module <Help> This warning indicates if the IL1 bi… |
| 1.3.6.1.4.1.20044.55.2.3.1.41.8 | ScalarpmoailhcAlmLineBiasHighWarning | read-only | current | IL1 Bias High Warning :This OID indicates that the Bias is higher than the Warning theshold of the IL1 Optical Module <Help> This warning indicates if the IL1 … |
| 1.3.6.1.4.1.20044.55.2.3.2 | NodepmoailhcAlmLineUrg | |||
| 1.3.6.1.4.1.20044.55.2.3.2.40 | NodepmoailhcAlmlineEdfaAlarms1 | |||
| 1.3.6.1.4.1.20044.55.2.3.2.40.1 | ScalarpmoailhcAlmLineGainLowAlarm | read-only | current | IL1 Gain Low Alarm :This OID indicates that the Gain is lower than the alarm theshold of the IL1 Module <Help> This alarm indicates if the IL1 gain is too low … |
| 1.3.6.1.4.1.20044.55.2.3.2.40.2 | ScalarpmoailhcAlmLineGainHighAlarm | read-only | current | IL1 Gain High Alarm :This OID indicates that the Gain is higher than the alarm threshold of the IL1 Module <Help> This alarm indicates if the IL1 gain is too h… |
| 1.3.6.1.4.1.20044.55.2.3.2.40.3 | ScalarpmoailhcAlmLineInputPwrLowAlarm | read-only | current | IL2 Rx Pwr Low Alarm :This OID indicates that the Receive Power is lower than the alarm theshold of the IL2 Optical Module <Help> This alarm indicates if the I… |
| 1.3.6.1.4.1.20044.55.2.3.2.40.4 | ScalarpmoailhcAlmLineInputPwrHighAlarm | read-only | current | IL2 Rx Pwr High Alarm :This OID indicates that the Receive Power is higher than the alarm theshold of the IL2 Optical Module <Help> This alarm indicates if the… |
| 1.3.6.1.4.1.20044.55.2.3.2.40.5 | ScalarpmoailhcAlmLineOutputPwrLowAlarm | read-only | current | IL1 Tx Pwr Low Alarm :This OID indicates that the Transmit Power is lower than the alarm theshold of the IL1 Optical Module <Help> This alarm indicates if the … |
| 1.3.6.1.4.1.20044.55.2.3.2.40.6 | ScalarpmoailhcAlmLineOutputPwrHighAlarm | read-only | current | IL1 Tx Pwr High Alarm :This OID indicates that the Transmit Power is higher than the alarm theshold of the IL1 Optical Module <Help> This alarm indicates if th… |
| 1.3.6.1.4.1.20044.55.2.3.2.40.7 | ScalarpmoailhcAlmLineBiasLowAlarm | read-only | current | IL1 Bias Low Alarm :This OID indicates that the Bias is lower than the alarm theshold of the IL1 Optical Module <Help> This alarm indicates if the IL1 bias is … |
| 1.3.6.1.4.1.20044.55.2.3.2.40.8 | ScalarpmoailhcAlmLineBiasHighAlarm | read-only | current | IL1 Bias High Alarm :This OID indicates that the Bias is higher than the alarm theshold of the IL1 Optical Module <Help> This alarm indicates if the IL1 bias i… |
| 1.3.6.1.4.1.20044.55.2.3.3 | NodepmoailhcAlmLineCrit | |||
| 1.3.6.1.4.1.20044.55.2.3.3.7 | NodepmoailhcAlmsynthAlm7 | |||
| 1.3.6.1.4.1.20044.55.2.3.3.7.4 | ScalarpmoailhcAlmLineHwFail | read-only | current | Line Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Condtype> LINE_HW_FAIL <Probcause> equipmentMalfunction (1… |
| 1.3.6.1.4.1.20044.55.2.3.3.7.5 | ScalarpmoailhcAlmLineTxOff | read-only | current | IL1 Optical Output Shutdown :This OID indicates the IL1 optical output power is on <Help> This status indicates if the IL1 laser pump is ON or OFF <Condtype> L… |
| 1.3.6.1.4.1.20044.55.2.3.3.7.9 | ScalarpmoailhcAlmLineDdmWarning | read-only | current | Warning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line optical interface DDM <Condtype> LINE_DDM_WARNING <Probcause> eq… |
| 1.3.6.1.4.1.20044.55.2.3.3.7.10 | ScalarpmoailhcAlmLineDdmAlm | read-only | current | Alarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line optical interface DDM <Condtype> LINE_DDM_ALM <Probcause> equipment… |
| 1.3.6.1.4.1.20044.55.2.3.3.7.12 | ScalarpmoailhcAlmLineFail | read-only | current | Line Port Failure :This OID indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12) <Po… |
| 1.3.6.1.4.1.20044.55.2.3.3.7.13 | ScalarpmoailhcAlmLineExtPumpFail | read-only | current | IL1 External Pump Fail :This OID indicates that the external pump linked to the IL1 is in fail condition <Help> This alarm indicates if the external pump linke… |
| 1.3.6.1.4.1.20044.55.2.3.3.43 | NodepmoailhcAlmlineEdfaAlarms2 | |||
| 1.3.6.1.4.1.20044.55.2.3.3.43.1 | ScalarpmoailhcAlmLineEdfaNr | read-only | current | IL1 Optical Module Not Ready :This OID indicates that the IL1 Optical Module is not ready <Help> This status indicates if the IL1 has been correctly initialize… |
| 1.3.6.1.4.1.20044.55.2.3.3.43.2 | ScalarpmoailhcAlmLineEdfaTecFail | read-only | current | IL1 TEC Fail :This OID indicates that the TEC is in fail condition on the IL1 Optical Module <Help> This alarm indicates if the TEC of the IL1 is in fail condi… |
| 1.3.6.1.4.1.20044.55.2.3.3.43.3 | ScalarpmoailhcAlmLineEdfaLaserFail | read-only | current | IL1 Pump Laser Fail :This OID indicates a Transmit Laser Fail on the IL1 Optical Module <Help> This alarm indicates if the laser of the IL1 is in fail conditio… |
| 1.3.6.1.4.1.20044.55.2.3.3.43.4 | ScalarpmoailhcAlmLineEdfaLos | read-only | current | IL2 Loss Of Signal :This OID indicates a Loss of Signal on the IL2 Optical Module <Help> This alarm indicates if an optical signal is detected on the IL2 input… |
| 1.3.6.1.4.1.20044.55.2.3.3.43.5 | ScalarpmoailhcAlmLineExtPumpEdfaLowCurrent | read-only | current | IL1 Pump Low Current :This OID indicates that the EDFA pump current of IL1 is too low because of the external pump high power<Help> This alarm (only active whe… |
| 1.3.6.1.4.1.20044.55.3 | Nodepmoailhcmeasures | |||
| 1.3.6.1.4.1.20044.55.3.1 | NodepmoailhcMesrOther | |||
| 1.3.6.1.4.1.20044.55.3.1.72 | ScalarpmoailhcMesrtempMeas | read-only | current | Module Temperature :This OID gives the temperature of the PM (Temperature =AV/256) (Unit = C) <Help> This measure gives the temperature of the module |
| 1.3.6.1.4.1.20044.55.3.2 | NodepmoailhcMesrClient | |||
| 1.3.6.1.4.1.20044.55.3.2.32 | ScalarpmoailhcMesrclientEdfaBiasMeas | read-only | current | IL2 Pump Laser Current :This OID gives the pump laser current of the IL2 Optical Module (Current =AV/100) (Unit = mA) <Help> This measure gives the bias of the… |
| 1.3.6.1.4.1.20044.55.3.2.33 | ScalarpmoailhcMesrclientEdfaTxpwrMeas | read-only | current | IL2 Tx Power :This OID gives the transmit power value of the IL2 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Tx optical… |
| 1.3.6.1.4.1.20044.55.3.2.34 | ScalarpmoailhcMesrclientEdfaRxpwrMeas | read-only | current | IL1 Rx Power :This OID gives the receive power value of the IL1 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Rx optical … |
| 1.3.6.1.4.1.20044.55.3.2.35 | ScalarpmoailhcMesrclientEdfaGainMeas | read-only | current | IL2 Gain Target :This OID gives the gain value of the IL2 Module (Gain =(AV-32768)*0,005) (Unit = dB) <Help> This information gives the target gain of the ampl… |
| 1.3.6.1.4.1.20044.55.3.2.38 | ScalarpmoailhcMesrclientCorrectedGain | read-only | current | IL2 Gain :This OID gives the gain value of the IL2 Module corrected by the ASE compensation mechanism (Gain =(AV-32768)*0,005) (Unit = dB) <Help> This measure … |
| 1.3.6.1.4.1.20044.55.3.3 | NodepmoailhcMesrLine | |||
| 1.3.6.1.4.1.20044.55.3.3.40 | ScalarpmoailhcMesrlineEdfaBiasMeas | read-only | current | IL1 Pump Laser Current :This OID gives the pump laser current of the IL1 Optical Module (Current =AV/100) (Unit = mA) <Help> This measure gives the bias of the… |
| 1.3.6.1.4.1.20044.55.3.3.41 | ScalarpmoailhcMesrlineEdfaTxpwrMeas | read-only | current | IL1 Tx Power :This OID gives the transmit power value of the IL1 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Tx optical… |
| 1.3.6.1.4.1.20044.55.3.3.42 | ScalarpmoailhcMesrlineEdfaRxpwrMeas | read-only | current | IL2 Rx Power :This OID gives the receive power value of the IL2 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Rx optical … |
| 1.3.6.1.4.1.20044.55.3.3.43 | ScalarpmoailhcMesrlineEdfaGainMeas | read-only | current | IL1 Gain Target :This OID gives the gain value of the IL1 Module (Gain =(AV-32768)*0,005) (Unit = dB) <Help> This information gives the target gain of the ampl… |
| 1.3.6.1.4.1.20044.55.3.3.46 | ScalarpmoailhcMesrlineCorrectedGain | read-only | current | IL1 Gain :This OID gives the gain value of the IL1 Module corrected by the ASE compensation mechanism (Gain =(AV-32768)*0,005) (Unit = dB) <Help> This measure … |
| 1.3.6.1.4.1.20044.55.6 | NodepmoailhccontrolsWrite | |||
| 1.3.6.1.4.1.20044.55.6.1 | NodepmoailhcCtrlOther | |||
| 1.3.6.1.4.1.20044.55.6.1.0 | NodepmoailhcCtrlsynth0 | |||
| 1.3.6.1.4.1.20044.55.6.1.0.1 | ScalarpmoailhcCtrlConfLoad | read-write | current | Load Configuration Tables :When set this enables loading from flash configuration1 into the module. |
| 1.3.6.1.4.1.20044.55.6.1.0.9 | ScalarpmoailhcCtrlConfFlash | read-write | current | Write Configuration Tables :This bit saves the current configuration of the module as configuration in the flash. <Help> This control saves the customer config… |
| 1.3.6.1.4.1.20044.55.6.1.0.13 | ScalarpmoailhcCtrlConfClear | read-write | current | Clear Configuration Tables :This bit clears the configuration tables from configuration in the flash. <Help> This control restores the default configuration of… |
| 1.3.6.1.4.1.20044.55.6.1.5 | NodepmoailhcCtrlswMgnt | |||
| 1.3.6.1.4.1.20044.55.6.1.5.2 | ScalarpmoailhcCtrlColdReset | read-write | current | PM Cold Reset :This OID, when set, causes a cold reset of the Software. This reset is traffic affecting, and the configuration of Software is reloaded on start… |
| 1.3.6.1.4.1.20044.55.6.1.5.3 | ScalarpmoailhcCtrlWarmReset | read-write | current | PM Warm Reset :This OID, when set, causes a warm reset of the Software. This reset is not traffic affecting, and the configuration of the Sofwtare remains unch… |
| 1.3.6.1.4.1.20044.55.6.1.73 | NodepmoailhcCtrlledTest | |||
| 1.3.6.1.4.1.20044.55.6.1.73.1 | ScalarpmoailhcCtrlGreenLed | read-write | current | Green Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green |
| 1.3.6.1.4.1.20044.55.6.1.73.2 | ScalarpmoailhcCtrlRedLed | read-write | current | Red Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red |
| 1.3.6.1.4.1.20044.55.6.1.73.3 | ScalarpmoailhcCtrlLedOff | read-write | current | Leds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF |
| 1.3.6.1.4.1.20044.55.6.1.75 | NodepmoailhcCtrlmaintMode | |||
| 1.3.6.1.4.1.20044.55.6.1.75.1 | ScalarpmoailhcCtrlMaintenance | read-write | current | PM Maintenance Mode :This OID sets the PM in maintenance mode <Help> This control enables the maintenance mode of the module |
| 1.3.6.1.4.1.20044.55.6.1.76 | NodepmoailhcCtrlaprRestart | |||
| 1.3.6.1.4.1.20044.55.6.1.76.1 | ScalarpmoailhcCtrlAprManualRestart | read-write | current | APR Manual Restart :This OID initiates the Restart mechanism to retrieve from the APR state.<Help> This control initiates the Restart mechanism to retrieve fro… |
| 1.3.6.1.4.1.20044.55.6.2 | NodepmoailhcCtrlClient | |||
| 1.3.6.1.4.1.20044.55.6.2.32 | NodepmoailhcCtrlclientEdfaLaserOff | |||
| 1.3.6.1.4.1.20044.55.6.2.32.1 | ScalarpmoailhcCtrlClientEdfaLaserOff | read-write | current | IL2 Optical Module Laser Off :This OID switches OFF the laser of the IL2li Optical Module <Help> This control defines the laser state of the IL2 |
| 1.3.6.1.4.1.20044.55.6.2.34 | ScalarpmoailhcCtrlclientGainCstMonitorValue | read-write | current | IL2 Fiber Aging Period :This OID sets the value of the monitoring period to detect a fiber aging. (Unit = s) This value sets the monitoring period to detect a … |
| 1.3.6.1.4.1.20044.55.6.2.35 | ScalarpmoailhcCtrlclientGainCstPoutValue | read-write | current | IL2 Ref Pout :This OID sets the value of the reference output power used to compensate the fiber aging (active only in constant gain mode) (AV=(Gain/0,005) + 3… |
| 1.3.6.1.4.1.20044.55.6.2.36 | ScalarpmoailhcCtrlclientGainSettingValue | read-write | current | IL2 Gain Target :This OID sets the value of the nominal gain of the IL2 Module (active only in constant output power mode) (AV=(Gain/0,005) + 32768) (Unit = dB… |
| 1.3.6.1.4.1.20044.55.6.2.37 | NodepmoailhcCtrlclientGainProcessing | |||
| 1.3.6.1.4.1.20044.55.6.2.37.1 | ScalarpmoailhcCtrlClientGainProc | read-write | current | IL2 Gain Adjustment :<Help> This control initiates the automatic nominal gain adjustment on the IL2 Module<Help> This control initiates the automatic nominal g… |
| 1.3.6.1.4.1.20044.55.6.2.38 | ScalarpmoailhcCtrlclientGainCstFiberAgingMarginValue | read-write | current | IL2 Aging Threshold :This OID sets the threshold to consider the power drop as a fiber aging. (active only in constant gain mode) (AV=(Gain/0,005) + 32768) (Un… |
| 1.3.6.1.4.1.20044.55.6.2.39 | ScalarpmoailhcCtrlclientGainCstAdddropMarginValue | read-write | current | IL2 AddDrop Threshold :This OID sets the threshold to not consider the power drop as a fiber aging. (active only in constant gain mode) (AV=(Gain/0,005) + 3276… |
| 1.3.6.1.4.1.20044.55.6.3 | NodepmoailhcCtrlLine | |||
| 1.3.6.1.4.1.20044.55.6.3.40 | NodepmoailhcCtrllineEdfaLaserOff | |||
| 1.3.6.1.4.1.20044.55.6.3.40.1 | ScalarpmoailhcCtrlLineEdfaLaserOff | read-write | current | IL1 Optical Module Laser Off :This OID switches OFF the laser of the IL1 Optical Module <Help> This control defines the laser state of the IL1 |
| 1.3.6.1.4.1.20044.55.6.3.42 | ScalarpmoailhcCtrllineGainCstMonitorValue | read-write | current | IL1 Fiber Aging Period :This OID sets the value of the monitoring period to detect a fiber aging. (Unit = s) This value sets the monitoring period to detect a … |
| 1.3.6.1.4.1.20044.55.6.3.43 | ScalarpmoailhcCtrllineGainCstPoutValue | read-write | current | IL1 Ref Pout :This OID sets the value of the reference output power used to compensate the fiber aging (active only in constant gain mode) (AV=(Gain/0,005) + 3… |
| 1.3.6.1.4.1.20044.55.6.3.44 | ScalarpmoailhcCtrllineGainSettingValue | read-write | current | IL1 Gain Target :This OID sets the value of the nominal gain of the IL1 Module (active only in constant output power mode) (AV=(Gain/0,005) + 32768) (Unit = dB… |
| 1.3.6.1.4.1.20044.55.6.3.45 | NodepmoailhcCtrllineGainProcessing | |||
| 1.3.6.1.4.1.20044.55.6.3.45.1 | ScalarpmoailhcCtrlLineGainProc | read-write | current | IL1 Gain Adjustment :This OID initiates the automatic nominal gain adjustment on the IL1 Module<Help> This control initiates the automatic nominal gain adjustm… |
| 1.3.6.1.4.1.20044.55.6.3.46 | ScalarpmoailhcCtrllineGainCstFiberAgingMarginValue | read-write | current | IL1 Aging Threshold :This OID sets the threshold to consider the power drop as a fiber aging. (active only in constant gain mode) (AV=(Gain/0,005) + 32768) (Un… |
| 1.3.6.1.4.1.20044.55.6.3.47 | ScalarpmoailhcCtrllineGainCstAdddropMarginValue | read-write | current | IL1 AddDrop Threshold :This OID sets the threshold to not consider the power drop as a fiber aging. (active only in constant gain mode) (AV=(Gain/0,005) + 3276… |
| 1.3.6.1.4.1.20044.55.7 | Nodepmoailhcri | |||
| 1.3.6.1.4.1.20044.55.7.2 | ScalarpmoailhcRinvReloadInventory | read-write | current | Reload the inventory: This OID triggers an inventory reload. |
| 1.3.6.1.4.1.20044.55.7.3 | ScalarpmoailhcRinvModulePlatform | read-only | current | Module platform description: This OID contains the description of the Module. |
| 1.3.6.1.4.1.20044.55.7.4 | ScalarpmoailhcRinvSwPlatform | read-only | current | SW platform description: This OID contains the description of the Software platform. |
| 1.3.6.1.4.1.20044.55.7.5 | ScalarpmoailhcRinvSwFoa | read-only | current | Optical device driver description: This OID contains the description of the driver of the optical devices (Booster and Pre-Amp) |
| 1.3.6.1.4.1.20044.55.7.6 | TablepmoailhcRinvInLine1Table | not-accessible | current | List of the InLine1s on the selected module |
| 1.3.6.1.4.1.20044.55.7.6.1 | RowpmoailhcRinvInLine1Entry | not-accessible | current | Row definition for the InLine1s table |
| 1.3.6.1.4.1.20044.55.7.6.1.1 | ColumnpmoailhcRinvInLine1Index | read-only | current | Index for InLine1 table |
| 1.3.6.1.4.1.20044.55.7.6.1.2 | ColumnpmoailhcRinvInLine1 | read-only | current | Inventory for the InLine1: This OID contains the inventory for the InLine1 |
| 1.3.6.1.4.1.20044.55.7.7 | TablepmoailhcRinvInLine2Table | not-accessible | current | List of the InLine2 on the selected module |
| 1.3.6.1.4.1.20044.55.7.7.1 | RowpmoailhcRinvInLine2Entry | not-accessible | current | Row definition for the InLine2 table |
| 1.3.6.1.4.1.20044.55.7.7.1.1 | ColumnpmoailhcRinvInLine2Index | read-only | current | Index for InLine2 table |
| 1.3.6.1.4.1.20044.55.7.7.1.2 | ColumnpmoailhcRinvInLine2 | read-only | current | Inventory for the InLine2: This OID contains the inventory for the InLine2 |
| 1.3.6.1.4.1.20044.55.9 | NodepmoailhcConfig | |||
| 1.3.6.1.4.1.20044.55.9.1 | NodepmoailhcCfgNoValue | |||
| 1.3.6.1.4.1.20044.55.9.1.1 | NodepmoailhctableclientStartup | |||
| 1.3.6.1.4.1.20044.55.9.1.1.2 | ScalarpmoailhcCfgclientEdfaLaserCtrl | read-write | current | Default Settings on Client Laser :This OID configures the default initialisation settings on the client laser. |
| 1.3.6.1.4.1.20044.55.9.1.1.3 | ScalarpmoailhcCfgclientEdfaLaserMode | read-write | current | Default Settings on Client mode :This OID configures the default mode on the client amplifier. |
| 1.3.6.1.4.1.20044.55.9.1.1.4 | ScalarpmoailhcCfgclientGainValue | read-write | current | Default Settings on Client Gain :This OID configures the default gain on the client amplifier. |
| 1.3.6.1.4.1.20044.55.9.1.1.5 | ScalarpmoailhcCfgclientTiltValue | read-write | current | Default Settings on Client Tilt :This OID configures the default tilt on the client amplifier. |
| 1.3.6.1.4.1.20044.55.9.1.1.6 | ScalarpmoailhcCfgclientMsaLoss | read-write | current | Default Settings on Client MSA :This OID configures the default MSA value on the client amplifier. |
| 1.3.6.1.4.1.20044.55.9.1.1.7 | ScalarpmoailhcCfgclientOutputPowerValue | read-write | current | Default Settings on Client Output power :This OID configures the default Output power value on the client amplifier. |
| 1.3.6.1.4.1.20044.55.9.1.1.8 | ScalarpmoailhcCfgclientAseCompensation | read-write | current | Default Settings on Client ASE :This OID configures the default ASE compensation value on the client amplifier. |
| 1.3.6.1.4.1.20044.55.9.2 | NodepmoailhcCfgLineStartUp | |||
| 1.3.6.1.4.1.20044.55.9.2.1 | NodepmoailhctablelineStartup | |||
| 1.3.6.1.4.1.20044.55.9.2.1.2 | ScalarpmoailhcCfglineEdfaLaserCtrl | read-write | current | Default Settings on Line Laser :This OID configures the default initialisation settings on the line laser. |
| 1.3.6.1.4.1.20044.55.9.2.1.3 | ScalarpmoailhcCfglineEdfaLaserMode | read-write | current | Default Settings on Line mode :This OID configures the default mode on the line amplifier. |
| 1.3.6.1.4.1.20044.55.9.2.1.4 | ScalarpmoailhcCfglineGainValue | read-write | current | Default Settings on Line Gain :This OID configures the default gain on the line amplifier. |
| 1.3.6.1.4.1.20044.55.9.2.1.5 | ScalarpmoailhcCfglineTiltValue | read-write | current | Default Settings on Line Tilt :This OID configures the default tilt on the line amplifier. |
| 1.3.6.1.4.1.20044.55.9.2.1.6 | ScalarpmoailhcCfglineMsaLoss | read-write | current | Default Settings on Line MSA :This OID configures the default MSA value on the line amplifier. |
| 1.3.6.1.4.1.20044.55.9.2.1.7 | ScalarpmoailhcCfglineOutputPowerValue | read-write | current | Default Settings on Line Output power :This OID configures the default Output power value on the line amplifier. |
| 1.3.6.1.4.1.20044.55.9.2.1.8 | ScalarpmoailhcCfglineAseCompensation | read-write | current | Default Settings on Line ASE :This OID configures the default ASE compensation value on the line amplifier. |
| 1.3.6.1.4.1.20044.55.9.2.1.11 | ScalarpmoailhcCfgaprMode | read-write | current | Default setting on module :This OID configures the default mode on the APR |
| 1.3.6.1.4.1.20044.55.9.3 | NodepmoailhcCfgLabels | |||
| 1.3.6.1.4.1.20044.55.9.3.1 | TablepmoailhcCfgLabelclientTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.55.9.3.1.1 | RowpmoailhcCfgLabelclientEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.55.9.3.1.1.1 | ColumnpmoailhcCfgLabelclientIndex | read-only | current | Index definition for the labelclient table |
| 1.3.6.1.4.1.20044.55.9.3.1.1.3 | ColumnpmoailhcCfgLabelclientPortn | read-write | current | Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. |
| 1.3.6.1.4.1.20044.55.9.3.2 | TablepmoailhcCfgLabellineTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.55.9.3.2.1 | RowpmoailhcCfgLabellineEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.55.9.3.2.1.1 | ColumnpmoailhcCfgLabellineIndex | read-only | current | Index definition for the labelline table |
| 1.3.6.1.4.1.20044.55.9.3.2.1.3 | ColumnpmoailhcCfgLabellinePortn | read-write | current | Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. |
| 1.3.6.1.4.1.20044.55.9.257 | ScalarpmoailhcCfgWriteConfiguration | read-write | current | Write configuration to module:This OID writes the complete configuration to the module |
| 1.3.6.1.4.1.20044.55.10 | Nodepmoailhctraps | |||
| 1.3.6.1.4.1.20044.55.10.4 | ScalarpmoailhctrapBoardNumber | read-only | current | Last module which generates a trap |
| 1.3.6.1.4.1.20044.55.10.30 | NotificationpmoailhcLineTrapNotUrgentGoesOn | current | Not urgent Line default is activated | |
| 1.3.6.1.4.1.20044.55.10.31 | NotificationpmoailhcLineTrapNotUrgentGoesOff | current | Not urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.55.10.32 | NotificationpmoailhcLineTrapUrgentGoesOn | current | Urgent Line default is activated | |
| 1.3.6.1.4.1.20044.55.10.33 | NotificationpmoailhcLineTrapUrgentGoesOff | current | Urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.55.10.34 | NotificationpmoailhcLineTrapCritGoesOn | current | Critical Line default is activated | |
| 1.3.6.1.4.1.20044.55.10.35 | NotificationpmoailhcLineTrapCritGoesOff | current | Critical Line default disappeared | |
| 1.3.6.1.4.1.20044.55.10.40 | NotificationpmoailhcClientTrapNotUrgentGoesOn | current | Not urgent client default is activated | |
| 1.3.6.1.4.1.20044.55.10.41 | NotificationpmoailhcClientTrapNotUrgentGoesOff | current | Not urgent client default disappeared | |
| 1.3.6.1.4.1.20044.55.10.42 | NotificationpmoailhcClientTrapUrgentGoesOn | current | Urgent client default is activated | |
| 1.3.6.1.4.1.20044.55.10.43 | NotificationpmoailhcClientTrapUrgentGoesOff | current | Urgent client default disappeared | |
| 1.3.6.1.4.1.20044.55.10.44 | NotificationpmoailhcClientTrapCritGoesOn | current | Critical client default is activated | |
| 1.3.6.1.4.1.20044.55.10.45 | NotificationpmoailhcClientTrapCritGoesOff | current | Critical client default disappeared | |
| 1.3.6.1.4.1.20044.55.10.50 | NotificationpmoailhcPowerTrapUrgentGoesOn | current | Urgent power supply default is activated | |
| 1.3.6.1.4.1.20044.55.10.51 | NotificationpmoailhcPowerTrapUrgentGoesOff | current | Urgent power supply default disappeared |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| PmoailhcaprMode | INTEGER { oailhcaproffmode(0), oailhcaprsemiautomode(1), oailhcaprautomode(2) oailhcaprlossforwardingmode(3) oailhcaprrepeatmode(4) } | current | Different modes on APR |
| PmoailhcBoosterCstGainAdjMode | INTEGER { oailhcboostercstgainadjsemiautomode(1), oailhcboostercstgainadjautomode(2) } | current | Different modes when constant Gain |
| PmoailhcBoosterGainAdjMode | INTEGER { oailhcboostergainadjmanualmode(0), oailhcboostergainadjsemiautomode(1), oailhcboostergainadjautomode(2) } | current | Different modes on Gain |
| PmoailhcboosterMode | INTEGER { oailhcboosterdefaultmode(0), oailhcboosterconstantcurrentmode(1), oailhcboosterconstantpowermode(2) oailhcboosterconstantgainmode(3) oailhcboosterpoutpinmode(4) oailhcboostermanualmode(5) oailhcboosterfeedforwardmode(6) oailhcboostertransientsupmode(7) } | current | Different modes on OA booster |
| PmoailhcPreampCstGainAdjMode | INTEGER { oailhcpreampcstgainadjsemiautomode(1), oailhcpreampcstgainadjautomode(2) } | current | Different modes when constant Gain |
| PmoailhcPreampGainAdjMode | INTEGER { oailhcpreampgainadjmanualmode(0), oailhcpreampgainadjsemiautomode(1), oailhcpreampgainadjautomode(2) } | current | Different modes on Gain |
| PmoailhcpreampMode | INTEGER { oailhcpreampdefaultmode(0), oailhcpreampconstantcurrentmode(1), oailhcpreampconstantpowermode(2) oailhcpreampconstantgainmode(3) oailhcpreamppoutpinmode(4) oailhcpreampmanualmode(5) oailhcpreampfeedforwardmode(6) oailhcpreamptransientsupmode(7) } | current | Different modes on OA preamp |