MIB Viewer

EKINOPS-Pmapc-MIB

204 objects
MIB for the Ekinops Pmapc hardware.
OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.42IdentitymodulePmapcMIB for the Ekinops Pmapc hardware.
1.3.6.1.4.1.20044.42.2Nodepmapcalarms
1.3.6.1.4.1.20044.42.2.1NodepmapcAlmOther
1.3.6.1.4.1.20044.42.2.1.1NodepmapcAlmOtherNurg
1.3.6.1.4.1.20044.42.2.1.1.2NodepmapcAlmsynthAlm2
1.3.6.1.4.1.20044.42.2.1.1.2.1ScalarpmapcAlmConfTableSaveread-onlycurrentPM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> other…
1.3.6.1.4.1.20044.42.2.1.1.2.2ScalarpmapcAlmInvUploadread-onlycurrentInventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> other (1) <Alarmtype> other (1) <Polarit…
1.3.6.1.4.1.20044.42.2.1.1.2.3ScalarpmapcAlmConfTableLoadread-onlycurrentPM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> other (1) <Alarmt…
1.3.6.1.4.1.20044.42.2.1.1.2.4ScalarpmapcAlmCorrelatOffread-onlycurrentNot Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> other (1) <Alarmtype> other (1) <Pol…
1.3.6.1.4.1.20044.42.2.1.1.65NodepmapcAlmmoduleWarning
1.3.6.1.4.1.20044.42.2.1.1.65.1ScalarpmapcAlmPwrInLowWngread-onlycurrentPower Input Low Warning :This OID indicates that input power of the transmit side is lower than the warning threshold <Help> This warning indicates if the rece…
1.3.6.1.4.1.20044.42.2.1.1.65.2ScalarpmapcAlmPwrInHighWngread-onlycurrentPower Input High Warning :This OID indicates that input power of the transmit side is higher than the warning threshold <Help> This warning indicates if the re…
1.3.6.1.4.1.20044.42.2.1.1.65.3ScalarpmapcAlmPwrOutLowWngread-onlycurrentPower Output Low Warning :This OID indicates that Output power of the transmit side is lower than the warning threshold <Help> This warning indicates if the tr…
1.3.6.1.4.1.20044.42.2.1.1.65.4ScalarpmapcAlmPwrOutHighWngread-onlycurrentPower Output High Warning :This OID indicates that Output power of the transmit side is higher than the warning threshold <Help> This warning indicates if the …
1.3.6.1.4.1.20044.42.2.1.1.65.5ScalarpmapcAlmEamAttLowWngread-onlycurrentEAM Attenuation Low Warning :This OID indicates that the attenuation of the EAM is lower than the warning threshold <Help> This warning indicates if the attenu…
1.3.6.1.4.1.20044.42.2.1.1.65.6ScalarpmapcAlmEamAttHighWngread-onlycurrentEAM Attenuation High Warning :EThis OID indicates that the attenuation of the EAM is higher than the warning threshold <Help> This warning indicates if the att…
1.3.6.1.4.1.20044.42.2.1.2NodepmapcAlmOtherUrg
1.3.6.1.4.1.20044.42.2.1.2.64NodepmapcAlmmoduleAlarm
1.3.6.1.4.1.20044.42.2.1.2.64.1ScalarpmapcAlmPwrInLowAlaread-onlycurrentPower Input Low Alarm :This OID indicates that input power of the transmit side is lower than the alarm threshold <Help> This alarm indicates if the received p…
1.3.6.1.4.1.20044.42.2.1.2.64.2ScalarpmapcAlmPwrInHighAlaread-onlycurrentPower Input High Alarm :This OID indicates that input power of the transmit side is higher than the alarm threshold <Help> This alarm indicates if the received…
1.3.6.1.4.1.20044.42.2.1.2.64.3ScalarpmapcAlmPwrOutLowAlaread-onlycurrentPower Output Low Alarm :This OID indicates that Output power of the transmit side is lower than the alarm threshold <Help> This alarm indicates if the transmit…
1.3.6.1.4.1.20044.42.2.1.2.64.4ScalarpmapcAlmPwrOutHighAlaread-onlycurrentPower Output High Alarm :This OID indicates that Output power of the transmit side is higher than the alarm threshold <Help> This alarm indicates if the transm…
1.3.6.1.4.1.20044.42.2.1.2.64.5ScalarpmapcAlmEamAttLowAlaread-onlycurrentEAM Attenuation Low Alarm :This OID indicates that the attenuation of the EAM is lower than the alarm threshold <Help> This alarm indicates if the attenuation …
1.3.6.1.4.1.20044.42.2.1.2.64.6ScalarpmapcAlmEamAttHighAlaread-onlycurrentEAM Attenuation High Alarm :This OID indicates that the attenuation of the EAM is higher than the alarm threshold <Help> This alarm indicates if the attenuatio…
1.3.6.1.4.1.20044.42.2.1.2.64.16ScalarpmapcAlmLossInputSignalread-onlycurrentLoss Of Input Signal :This OID indicates there is a Loss of Signal on the input of the module. <Help> This alarm indicates if there is a Loss of Signal of the …
1.3.6.1.4.1.20044.42.2.1.2.70NodepmapcAlmmodInitFailLevel2
1.3.6.1.4.1.20044.42.2.1.2.70.1ScalarpmapcAlmRegReadFailread-onlycurrentReg_Read_Fail : <Condtype> REG_READ_FAIL <Probcause> softwareError (47) <Alarmtype> processingErrorAlarm (4) <Polarity> (2)
1.3.6.1.4.1.20044.42.2.1.2.70.2ScalarpmapcAlmResetHwInitFailread-onlycurrentReset_HW_Init_Fail : <Condtype> RESET_HW_INIT_FAIL <Probcause> softwareError (47) <Alarmtype> processingErrorAlarm (4) <Polarity> (2)
1.3.6.1.4.1.20044.42.2.1.2.70.3ScalarpmapcAlmConfReadFailread-onlycurrentConf_Read_Fail : <Condtype> CONF_READ_FAIL <Probcause> softwareError (47) <Alarmtype> processingErrorAlarm (4) <Polarity> (2)
1.3.6.1.4.1.20044.42.2.1.2.70.4ScalarpmapcAlmInvReadFailread-onlycurrent: <Condtype> INV_READ_FAIL <Probcause> softwareError (47) <Alarmtype> processingErrorAlarm (4) <Polarity> (2)
1.3.6.1.4.1.20044.42.2.1.2.70.6ScalarpmapcAlmCalibReadFailread-onlycurrentCalib_Read_Fail : <Condtype> CALIB_READ_FAIL <Probcause> softwareError (47) <Alarmtype> processingErrorAlarm (4) <Polarity> (2)
1.3.6.1.4.1.20044.42.2.1.2.70.7ScalarpmapcAlmThreshConfFailread-onlycurrentThresh_Conf_Fail : <Condtype> THRESH_CONF_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> equipmentAlarm (5) <Polarity> (2)
1.3.6.1.4.1.20044.42.2.1.2.71NodepmapcAlmmodInitFailLevel3
1.3.6.1.4.1.20044.42.2.1.2.71.1ScalarpmapcAlmOptIdentFailread-onlycurrentOpt_Ident_Fail : <Condtype> OPT_IDENT_FAIL <Probcause> softwareError (47) <Alarmtype> processingErrorAlarm (4) <Polarity> (2)
1.3.6.1.4.1.20044.42.2.1.3NodepmapcAlmOtherCrit
1.3.6.1.4.1.20044.42.2.1.3.0NodepmapcAlmsynthAlm0
1.3.6.1.4.1.20044.42.2.1.3.0.5ScalarpmapcAlmPwrInAlaread-onlycurrentPower Input Alarm :This OID indicates that the power input on the transmit side is in fail condition <Help> This alarm indicates that the power input is in an …
1.3.6.1.4.1.20044.42.2.1.3.0.6ScalarpmapcAlmPwrInWngread-onlycurrentPower Input Warning :This OID indicates that the power input on the transmit side is in warning condition <Help> This warning indicates that the power input is…
1.3.6.1.4.1.20044.42.2.1.3.0.7ScalarpmapcAlmPwrOutAlaread-onlycurrentPower Output Alarm :This OID indicates that the power output on the transmit side is in fail condition <Help> This alarm indicates that the power output is in …
1.3.6.1.4.1.20044.42.2.1.3.0.8ScalarpmapcAlmPwrOutWngread-onlycurrentPower Output Warning :This OID indicates that the power output on the transmit side is in warning condition <Help> This warning indicates that the power output…
1.3.6.1.4.1.20044.42.2.1.3.0.9ScalarpmapcAlmModuleGlobFailureread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the PM <Condtype> MODULE_GLOB_FAILURE <Probcause> equipmentMalfunction (16) <Alarmty…
1.3.6.1.4.1.20044.42.2.1.3.0.15ScalarpmapcAlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.42.2.1.3.0.16ScalarpmapcAlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.42.2.2NodepmapcAlmClient
1.3.6.1.4.1.20044.42.2.2.1NodepmapcAlmClientNurg
1.3.6.1.4.1.20044.42.2.2.1.18NodepmapcAlmlaser1MeasWng
1.3.6.1.4.1.20044.42.2.2.1.18.1ScalarpmapcAlmPwrLas1LowWngread-onlycurrentLaser 1 Pwr Low Warning :This OID indicates that transmit power of the Stuffing Wavelength Laser 1 is lower than the warning threshold <Help> This warning indi…
1.3.6.1.4.1.20044.42.2.2.1.18.2ScalarpmapcAlmPwrLas1HighWngread-onlycurrentLaser 1 Pwr High Warning :This OID indicates that transmit power of the Stuffing Wavelength Laser 1 is higher than the warning threshold <Help> This warning in…
1.3.6.1.4.1.20044.42.2.2.1.18.3ScalarpmapcAlmVthLas1LowWngread-onlycurrentLaser 1 TEC Temp Low Warning :This OID indicates that the TEC temperature of the Stuffing Wavelength Laser 1 is lower than the warning threshold <Help> This wa…
1.3.6.1.4.1.20044.42.2.2.1.18.4ScalarpmapcAlmVthLas1HighWngread-onlycurrentLaser 1 TEC Temp High Warning :This OID indicates that the TEC temperature of the Stuffing Wavelength Laser 1 is higher than the warning threshold <Help> This …
1.3.6.1.4.1.20044.42.2.2.1.18.5ScalarpmapcAlmVtecLas1LowWngread-onlycurrentLaser 1 TEC Volt Low Warning :This OID indicates that the TEC voltage of the Stuffing Wavelength Laser 1 is lower than the warning threshold <Help> This warnin…
1.3.6.1.4.1.20044.42.2.2.1.18.6ScalarpmapcAlmVtecLas1HighWngread-onlycurrentLaser 1 TEC Volt High Warning :This OID indicates that the TEC voltage of the Stuffing Wavelength Laser 1 is higher than the warning threshold <Help> This warn…
1.3.6.1.4.1.20044.42.2.2.1.18.7ScalarpmapcAlmILas1LowWngread-onlycurrentLaser 1 Current Low Warning :This OID indicates that the current of the Stuffing Wavelength Laser 1 is lower than the warning threshold <Help> This warning ind…
1.3.6.1.4.1.20044.42.2.2.1.18.8ScalarpmapcAlmILas1HighWngread-onlycurrentLaser 1 Current High Warning :This OID indicates that the current of the Stuffing Wavelength Laser 1 is higher than the warning threshold <Help> This warning i…
1.3.6.1.4.1.20044.42.2.2.2NodepmapcAlmClientUrg
1.3.6.1.4.1.20044.42.2.2.2.16NodepmapcAlmlaser1Alm
1.3.6.1.4.1.20044.42.2.2.2.16.1ScalarpmapcAlmLas1Failread-onlycurrentStuff. Wavelength 1 Fail :This OID indicates that the Stuffing Wavelength Laser 1 failed on the transmit side <Help> This alarm indicates if the laser of the t…
1.3.6.1.4.1.20044.42.2.2.2.16.2ScalarpmapcAlmLas1Tec1Failread-onlycurrentStuff. Wavelength 1 TEC Fail :This OID indicates that the TEC of the Stuffing Wavelength Laser 1 failed on the transmit side. <Help> This alarm indicates if th…
1.3.6.1.4.1.20044.42.2.2.2.17NodepmapcAlmlaser1MeasAlm
1.3.6.1.4.1.20044.42.2.2.2.17.1ScalarpmapcAlmPwrLas1LowAlaread-onlycurrentLaser 1 Pwr Low Alarm :This OID indicates that transmit power of the Stuffing Wavelength Laser 1 is lower than the alarm threshold <Help> This alarm indicates …
1.3.6.1.4.1.20044.42.2.2.2.17.2ScalarpmapcAlmPwrLas1HighAlaread-onlycurrentLaser 1 Pwr High Alarm :This OID indicates that transmit power of the Stuffing Wavelength Laser 1 is higher than the alarm threshold <Help> This alarm indicate…
1.3.6.1.4.1.20044.42.2.2.2.17.3ScalarpmapcAlmVthLas1LowAlaread-onlycurrentLaser 1 TEC Temp Low Alarm :This OID indicates that the TEC temperature of the Stuffing Wavelength Laser 1 is lower than the alarm threshold <Help> This alarm …
1.3.6.1.4.1.20044.42.2.2.2.17.4ScalarpmapcAlmVthLas1HighAlaread-onlycurrentLaser 1 TEC Temp High Alarm :This OID indicates that the TEC temperature of the Stuffing Wavelength Laser 1 is higher than the alarm threshold <Help> This alar…
1.3.6.1.4.1.20044.42.2.2.2.17.5ScalarpmapcAlmVtecLas1LowAlaread-onlycurrentLaser 1 TEC Volt Low Alarm :This OID indicates that the TEC voltage of the Stuffing Wavelength Laser 1 is lower than the alarm threshold <Help> This alarm indi…
1.3.6.1.4.1.20044.42.2.2.2.17.6ScalarpmapcAlmVtecLas1HighAlaread-onlycurrentLaser 1 TEC Volt High Alarm :This OID indicates that the TEC voltage of the Stuffing Wavelength Laser 1 is higher than the alarm threshold <Help> This alarm in…
1.3.6.1.4.1.20044.42.2.2.2.17.7ScalarpmapcAlmILas1LowAlaread-onlycurrentLaser 1 Current Low Alarm :This OID indicates that the current of the Stuffing Wavelength Laser 1 is lower than the alarm threshold <Help> This alarm indicates…
1.3.6.1.4.1.20044.42.2.2.2.17.8ScalarpmapcAlmILas1HighAlaread-onlycurrentLaser 1 Current High Alarm :This OID indicates that the current of the Stuffing Wavelength Laser 1 is higher than the alarm threshold <Help> This alarm indicat…
1.3.6.1.4.1.20044.42.2.2.3NodepmapcAlmClientCrit
1.3.6.1.4.1.20044.42.2.2.3.8NodepmapcAlmsynthAlmLaser1
1.3.6.1.4.1.20044.42.2.2.3.8.2ScalarpmapcAlmLas1InitNotComplread-onlycurrentStuff. Wavelength 1 Not Ready :This OID indicates that the optical interface of the Stuffing Wavelength Laser 1 is not operational. <Help> This status indicate…
1.3.6.1.4.1.20044.42.2.2.3.8.4ScalarpmapcAlmLas1HwFailAccread-onlycurrentStuff. Wavelength 1 HW Fail :This OID indicates a hardware failure on the Stuffing Wavelength Laser 1 <Condtype> LAS1_HW_FAIL_ACC <Probcause> equipmentMalfunct…
1.3.6.1.4.1.20044.42.2.2.3.8.6ScalarpmapcAlmLas1LocalOosread-onlycurrentStuff. Wavelength 1 Out Of Service :This OID indicates that the Stuffing Wavelength Laser 1 is In Service (1) of Out or Service (2). <Help> This status indicat…
1.3.6.1.4.1.20044.42.2.2.3.8.9ScalarpmapcAlmLas1MeasWngread-onlycurrentStuff. Wavelength 1 Warning :This OID indicates a warning is present coming out of Stuffing Wavelength Laser 1 monitoring <Help> This alarm indicates if a moni…
1.3.6.1.4.1.20044.42.2.2.3.8.10ScalarpmapcAlmLas1MeasAlmread-onlycurrentStuff. Wavelength 1 Alarm :This OID indicates if an alarm is present coming out of Stuffing Wavelength Laser 1 monitoring <Help> This alarm indicates if a moni…
1.3.6.1.4.1.20044.42.2.2.3.8.12ScalarpmapcAlmLas1FailAccread-onlycurrentStuff. Wavelength 1 Fail :This OID indicates a failure on the Stuffing Wavelength Laser 1 <Condtype> LAS1_FAIL_ACC <Probcause> equipmentMalfunction (16) <Alarm…
1.3.6.1.4.1.20044.42.2.2.3.9NodepmapcAlmsynthAlmLaser2
1.3.6.1.4.1.20044.42.2.2.3.9.2ScalarpmapcAlmLas2InitNotComplread-onlycurrentStuff. Wavelength 2 Not Ready :This OID indicates that the optical interface of the Stuffing Wavelength Laser 2 is not operational. <Help> This status indicate…
1.3.6.1.4.1.20044.42.2.2.3.9.4ScalarpmapcAlmLas2HwFailAccread-onlycurrentStuff. Wavelength 2 HW Fail :This OID indicates a hardware failure on the Stuffing Wavelength Laser 2 <Condtype> LAS2_HW_FAIL_ACC <Probcause> equipmentMalfunct…
1.3.6.1.4.1.20044.42.2.2.3.9.6ScalarpmapcAlmLas2LocalOosread-onlycurrentStuff. Wavelength 2 Out Of Service :This OID indicates that the Stuffing Wavelength Laser 2 is In Service (2) of Out or Service (2). <Help> This status indicat…
1.3.6.1.4.1.20044.42.2.2.3.9.9ScalarpmapcAlmLas2MeasWngread-onlycurrentStuff. Wavelength 2 Warning :This OID indicates a warning is present coming out of Stuffing Wavelength Laser 2 monitoring <Help> This alarm indicates if a moni…
1.3.6.1.4.1.20044.42.2.2.3.9.10ScalarpmapcAlmLas2MeasAlmread-onlycurrentStuff. Wavelength 2 Alarm :This OID indicates if an alarm is present coming out of Stuffing Wavelength Laser 2 monitoring <Help> This alarm indicates if a moni…
1.3.6.1.4.1.20044.42.2.2.3.9.12ScalarpmapcAlmLas2FailAccread-onlycurrentStuff. Wavelength 2 Fail :This OID indicates a failure on the Stuffing Wavelength Laser 2 <Condtype> LAS2_FAIL_ACC <Probcause> equipmentMalfunction (16) <Alarm…
1.3.6.1.4.1.20044.42.2.3NodepmapcAlmLine
1.3.6.1.4.1.20044.42.2.3.1NodepmapcAlmLineNurg
1.3.6.1.4.1.20044.42.2.3.1.26NodepmapcAlmlaser2MeasWng
1.3.6.1.4.1.20044.42.2.3.1.26.1ScalarpmapcAlmPwrLas2LowWngread-onlycurrentLaser 2 Pwr Low Warning :This OID indicates that transmit power of the Stuffing Wavelength Laser 2 is lower than the warning threshold <Help> This warning indi…
1.3.6.1.4.1.20044.42.2.3.1.26.2ScalarpmapcAlmPwrLas2HighWngread-onlycurrentLaser 2 Pwr High Warning :This OID indicates that transmit power of the Stuffing Wavelength Laser 2 is higher than the warning threshold <Help> This warning in…
1.3.6.1.4.1.20044.42.2.3.1.26.3ScalarpmapcAlmVthLas2LowWngread-onlycurrentLaser 2 TEC Temp Low Warning :This OID indicates that the TEC temperature of the Stuffing Wavelength Laser 2 is lower than the warning threshold <Help> This wa…
1.3.6.1.4.1.20044.42.2.3.1.26.4ScalarpmapcAlmVthLas2HighWngread-onlycurrentLaser 2 TEC Temp High Warning :This OID indicates that the TEC temperature of the Stuffing Wavelength Laser 2 is higher than the warning threshold <Help> This …
1.3.6.1.4.1.20044.42.2.3.1.26.5ScalarpmapcAlmVtecLas2LowWngread-onlycurrentLaser 2 TEC Volt Low Warning :This OID indicates that the TEC voltage of the Stuffing Wavelength Laser 2 is lower than the warning threshold <Help> This warnin…
1.3.6.1.4.1.20044.42.2.3.1.26.6ScalarpmapcAlmVtecLas2HighWngread-onlycurrentLaser 2 TEC Volt High Warning :This OID indicates that the TEC voltage of the Stuffing Wavelength Laser 2 is higher than the warning threshold <Help> This warn…
1.3.6.1.4.1.20044.42.2.3.1.26.7ScalarpmapcAlmILas2LowWngread-onlycurrentLaser 2 Current Low Warning :This OID indicates that the current of the Stuffing Wavelength Laser 2 is lower than the warning threshold <Help> This warning ind…
1.3.6.1.4.1.20044.42.2.3.1.26.8ScalarpmapcAlmILas2HighWngread-onlycurrentLaser 2 Current High Warning :This OID indicates that the current of the Stuffing Wavelength Laser 2 is higher than the warning threshold <Help> This warning i…
1.3.6.1.4.1.20044.42.2.3.2NodepmapcAlmLineUrg
1.3.6.1.4.1.20044.42.2.3.2.24NodepmapcAlmlaser2Alm
1.3.6.1.4.1.20044.42.2.3.2.24.1ScalarpmapcAlmLas2Failread-onlycurrentStuff. Wavelength 2 Fail :This OID indicates that the Stuffing Wavelength Laser 2 failed on the transmit side <Help> This alarm indicates if the laser of the t…
1.3.6.1.4.1.20044.42.2.3.2.24.2ScalarpmapcAlmLas2TecFailread-onlycurrentStuff. Wavelength 2 TEC Fail :This OID indicates that the TEC of the Stuffing Wavelength Laser 2 failed on the transmit side. <Help> This alarm indicates if th…
1.3.6.1.4.1.20044.42.2.3.2.25NodepmapcAlmlaser2MeasAla
1.3.6.1.4.1.20044.42.2.3.2.25.1ScalarpmapcAlmPwrLas2LowAlaread-onlycurrentLaser 2 Pwr Low Alarm :This OID indicates that transmit power of the Stuffing Wavelength Laser 2 is lower than the alarm threshold <Help> This alarm indicates …
1.3.6.1.4.1.20044.42.2.3.2.25.2ScalarpmapcAlmPwrLas2HighAlaread-onlycurrentLaser 2 Pwr High Alarm :This OID indicates that transmit power of the Stuffing Wavelength Laser 2 is higher than the alarm threshold <Help> This alarm indicate…
1.3.6.1.4.1.20044.42.2.3.2.25.3ScalarpmapcAlmVthLas2LowAlaread-onlycurrentLaser 2 TEC Temp Low Alarm :This OID indicates that the TEC temperature of the Stuffing Wavelength Laser 2 is lower than the alarm threshold <Help> This alarm …
1.3.6.1.4.1.20044.42.2.3.2.25.4ScalarpmapcAlmVthLas2HighAlaread-onlycurrentLaser 2 TEC Temp High Alarm :This OID indicates that the TEC temperature of the Stuffing Wavelength Laser 2 is higher than the alarm threshold <Help> This alar…
1.3.6.1.4.1.20044.42.2.3.2.25.5ScalarpmapcAlmVtecLas2LowAlaread-onlycurrentLaser 2 TEC Volt Low Alarm :This OID indicates that the TEC voltage of the Stuffing Wavelength Laser 2 is lower than the alarm threshold <Help> This alarm indi…
1.3.6.1.4.1.20044.42.2.3.2.25.6ScalarpmapcAlmVtecLas2HighAlaread-onlycurrentLaser 2 TEC Volt High Alarm :This OID indicates that the TEC voltage of the Stuffing Wavelength Laser 2 is higher than the alarm threshold <Help> This alarm in…
1.3.6.1.4.1.20044.42.2.3.2.25.7ScalarpmapcAlmILas2LowAlaread-onlycurrentLaser 2 Current Low Alarm :This OID indicates that the current of the Stuffing Wavelength Laser 2 is lower than the alarm threshold <Help> This alarm indicates…
1.3.6.1.4.1.20044.42.2.3.2.25.8ScalarpmapcAlmILas2HighAlaread-onlycurrentLaser 2 Current High Alarm :This OID indicates that the current of the Stuffing Wavelength Laser 2 is higher than the alarm threshold <Help> This alarm indicat…
1.3.6.1.4.1.20044.42.2.3.3NodepmapcAlmLineCrit
1.3.6.1.4.1.20044.42.3Nodepmapcmeasures
1.3.6.1.4.1.20044.42.3.1NodepmapcMesrOther
1.3.6.1.4.1.20044.42.3.1.64ScalarpmapcMesrmodulePowerInread-onlycurrentModule Input Power :This OID gives the input power of the module (Power=(AV-32768)*0.005) (Unit = dBm) <Help> This measure gives the input power of the module
1.3.6.1.4.1.20044.42.3.1.65ScalarpmapcMesrmoduleVPowerOutread-onlycurrentModule Output Power Voltage :This OID gives the output power voltage (Voltage = AV/10000) (Unit = V) <Help> This measure gives the output power voltage of the …
1.3.6.1.4.1.20044.42.3.1.66ScalarpmapcMesrmoduleEamAttread-onlycurrentStuffing Lasers Attenuation :This OID gives the attenuation level applied on the stuffing lasers in percent (0: not attenuation, 100: full attenuation) (Attenu…
1.3.6.1.4.1.20044.42.3.1.67ScalarpmapcMesrmoduleTempread-onlycurrentModule Temperature :This OID gives the module temperature (Temperature = AV/256) (Unit = C) <Help> This measure gives the module temperature
1.3.6.1.4.1.20044.42.3.1.68ScalarpmapcMesrmodule33vread-onlycurrentModule 3.3 Voltage :This OID gives the module 3V3 Voltage (Voltage = AV/10000) (Unit = V) <Help> This measure gives the module 3V3 Voltage
1.3.6.1.4.1.20044.42.3.2NodepmapcMesrClient
1.3.6.1.4.1.20044.42.3.2.16ScalarpmapcMesrpowerLas1read-onlycurrentStuff, Wavelength 1 Power :This OID gives the power value of the Sutfing Wavelength 1 Laser (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the …
1.3.6.1.4.1.20044.42.3.2.17ScalarpmapcMesrvthLas1read-onlycurrentStuff. Wavelength 1 Temp. Reg. Volt :This OID gives the Voltage of the Temperature Regulator of the Stuffing Wavelength 1 (Voltage = AV/10000) (Unit = V) <Help…
1.3.6.1.4.1.20044.42.3.2.18ScalarpmapcMesrvtecLas1read-onlycurrentStuff. Wavelength 1 TEC Voltage :This OID gives the Voltage of the TEC of the Stuffing Wavelength 1 (Voltage = AV/10000) (Unit = V) <Help> This measure gives t…
1.3.6.1.4.1.20044.42.3.2.19ScalarpmapcMesriLas1read-onlycurrent:
1.3.6.1.4.1.20044.42.3.3NodepmapcMesrLine
1.3.6.1.4.1.20044.42.3.3.24ScalarpmapcMesrpowerLas2read-onlycurrentStuff, Wavelength 2 Power :This OID gives the power value of the Sutfing Wavelength 2 Laser (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the …
1.3.6.1.4.1.20044.42.3.3.25ScalarpmapcMesrvthLas2read-onlycurrentStuff. Wavelength 2 Temp. Reg. Volt :This OID gives the Voltage of the Temperature Regulator of the Stuffing Wavelength 2 (Voltage = AV/10000) (Unit = V) <Help…
1.3.6.1.4.1.20044.42.3.3.26ScalarpmapcMesrvtecLas2read-onlycurrentStuff. Wavelength 2 TEC Voltage :This OID gives the Voltage of the TEC of the Stuffing Wavelength 2 (Voltage = AV/10000) (Unit = V) <Help> This measure gives t…
1.3.6.1.4.1.20044.42.3.3.27ScalarpmapcMesriLas2read-onlycurrent:
1.3.6.1.4.1.20044.42.6NodepmapccontrolsWrite
1.3.6.1.4.1.20044.42.6.1NodepmapcCtrlOther
1.3.6.1.4.1.20044.42.6.1.0NodepmapcCtrlsynth0
1.3.6.1.4.1.20044.42.6.1.0.1ScalarpmapcCtrlConfLoadread-writecurrentLoad Configuration Tables :When set this enables loading from flash configuration1 into the module.
1.3.6.1.4.1.20044.42.6.1.0.9ScalarpmapcCtrlConfFlashread-writecurrentWrite Configuration Tables :This bit saves the current configuration of the module as configuration in the flash. <Help> This control saves the customer config…
1.3.6.1.4.1.20044.42.6.1.0.13ScalarpmapcCtrlConfClearread-writecurrentClear Configuration Tables :This bit clears the configuration tables from configuration in the flash. <Help> This control restores the default configuration of…
1.3.6.1.4.1.20044.42.6.1.4NodepmapcCtrlsynth4
1.3.6.1.4.1.20044.42.6.1.4.1ScalarpmapcCtrlCorrelatOnread-writecurrentEnable Alarm Correlation :This OID enables the alarm correlation in the PM.
1.3.6.1.4.1.20044.42.6.1.4.2ScalarpmapcCtrlCorrelatOffread-writecurrentDisable Alarm Correlation :This OID disables the alarm correlation in the PM.
1.3.6.1.4.1.20044.42.6.1.5NodepmapcCtrlswMgnt
1.3.6.1.4.1.20044.42.6.1.5.2ScalarpmapcCtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the Software. This reset is traffic affecting, and the configuration of Software is reloaded on start…
1.3.6.1.4.1.20044.42.6.1.5.3ScalarpmapcCtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the Software. This reset is not traffic affecting, and the configuration of the Sofwtare remains unch…
1.3.6.1.4.1.20044.42.6.1.64NodepmapcCtrlledTest
1.3.6.1.4.1.20044.42.6.1.64.1ScalarpmapcCtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.42.6.1.64.2ScalarpmapcCtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.42.6.1.64.3ScalarpmapcCtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.42.6.2NodepmapcCtrlClient
1.3.6.1.4.1.20044.42.6.2.16NodepmapcCtrllaser1Shutdown
1.3.6.1.4.1.20044.42.6.2.16.1ScalarpmapcCtrlLaser1Shutdownread-writecurrentStuff. Wavelength 1 Laser Shutdown :This OID shuts down the laser of the Stuffing Wavelength 1 <Help> This control shuts down the laser of the Stuffing Wavelen…
1.3.6.1.4.1.20044.42.6.2.18NodepmapcCtrllaser1Oos
1.3.6.1.4.1.20044.42.6.2.18.1ScalarpmapcCtrlLaser1OosModeread-writecurrentStuff. Wavelength 1 Out Of Service :This OID sets the Stuffing Wavelength 1 Out of Service <Help> This controls defines the service state of the Stuffing Wavel…
1.3.6.1.4.1.20044.42.6.3NodepmapcCtrlLine
1.3.6.1.4.1.20044.42.6.3.17NodepmapcCtrllaser2Shutdown
1.3.6.1.4.1.20044.42.6.3.17.1ScalarpmapcCtrlLaser2Shutdownread-writecurrentStuff. Wavelength 2 Laser Shutdown :This OID shuts down the laser of the Stuffing Wavelength 2 <Help> This control shuts down the laser of the Stuffing Wavelen…
1.3.6.1.4.1.20044.42.6.3.19NodepmapcCtrllaser2Oos
1.3.6.1.4.1.20044.42.6.3.19.1ScalarpmapcCtrlLaser2OosModeread-writecurrentStuff. Wavelength 2 Out Of Service :This OID sets the Stuffing Wavelength 2 Out of Service <Help> This controls defines the service state of the Stuffing Wavel…
1.3.6.1.4.1.20044.42.6.3.65ScalarpmapcCtrlmoduleOutputPwrSettingread-writecurrentModule Output Power [-14 , +6] :This OID sets the output power of the module (AV=(Power/0.005)+32768) (Unit = dBm) <Help> This control defines the output power…
1.3.6.1.4.1.20044.42.6.3.66ScalarpmapcCtrlmoduleInputPwrSettingread-writecurrentModule Input Power :This OID sets the input power of the module (AV=(Power/0.005)+32768) (Unit = dBm) <Help> This control defines the input power of the module
1.3.6.1.4.1.20044.42.7Nodepmapcri
1.3.6.1.4.1.20044.42.7.1NodepmapcriTable
1.3.6.1.4.1.20044.42.7.1.1TablepmapcRinvLaser1Tablenot-accessiblecurrentList of the laser clients on the selected module
1.3.6.1.4.1.20044.42.7.1.1.1RowpmapcRinvLaser1Entrynot-accessiblecurrentRow definition for the laser client table
1.3.6.1.4.1.20044.42.7.1.1.1.1ColumnpmapcRinvLaser1Indexread-onlycurrentIndex for laser client table
1.3.6.1.4.1.20044.42.7.1.1.1.2ColumnpmapcRinvLaser1read-onlycurrentInventory for the laser client: This OID contains the inventory for the laser client
1.3.6.1.4.1.20044.42.7.1.2TablepmapcRinvLaser2Tablenot-accessiblecurrentList of the laser clients on the selected module
1.3.6.1.4.1.20044.42.7.1.2.1RowpmapcRinvLaser2Entrynot-accessiblecurrentRow definition for the laser client table
1.3.6.1.4.1.20044.42.7.1.2.1.1ColumnpmapcRinvLaser2Indexread-onlycurrentIndex for laser client table
1.3.6.1.4.1.20044.42.7.1.2.1.2ColumnpmapcRinvLaser2read-onlycurrentInventory for the laser client: This OID contains the inventory for the laser client
1.3.6.1.4.1.20044.42.7.2ScalarpmapcRinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.42.7.3ScalarpmapcRinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.42.7.4ScalarpmapcRinvModulePlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.42.7.5ScalarpmapcRinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.42.9NodepmapcConfig
1.3.6.1.4.1.20044.42.9.1NodepmapcCfgLsd
1.3.6.1.4.1.20044.42.9.1.1NodepmapctablecomaLsd
1.3.6.1.4.1.20044.42.9.2NodepmapcCfgStartUp
1.3.6.1.4.1.20044.42.9.2.1NodepmapctablecomaStartup
1.3.6.1.4.1.20044.42.9.2.1.2ScalarpmapcCfglaser1Oosread-writecurrentDefault setting on laser 1 :This register configures the default service state on laser 1
1.3.6.1.4.1.20044.42.9.2.2NodepmapctablecombStartup
1.3.6.1.4.1.20044.42.9.2.2.2ScalarpmapcCfglaser2Oosread-writecurrentDefault setting on laser 2 :This register configures the default service state on laser 2
1.3.6.1.4.1.20044.42.9.2.2.10ScalarpmapcCfgmoduleOutputPwrSettingread-writecurrentDefault setting on module output power :This register configures the default output power level of the module
1.3.6.1.4.1.20044.42.9.2.2.11ScalarpmapcCfgmoduleInputPwrSettingread-writecurrentDefault setting on module input power :This register configures the default input power level of the module
1.3.6.1.4.1.20044.42.9.3NodepmapcCfgLabels
1.3.6.1.4.1.20044.42.9.3.1TablepmapcCfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.42.9.3.1.1RowpmapcCfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.42.9.3.1.1.1ColumnpmapcCfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.42.9.3.1.1.3ColumnpmapcCfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.42.9.3.2TablepmapcCfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.42.9.3.2.1RowpmapcCfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.42.9.3.2.1.1ColumnpmapcCfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.42.9.3.2.1.3ColumnpmapcCfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.42.9.257ScalarpmapcCfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.42.10Nodepmapctraps
1.3.6.1.4.1.20044.42.10.2ScalarpmapctrapPortNumberread-onlycurrentLast port which generates a trap
1.3.6.1.4.1.20044.42.10.3ScalarpmapctrapLineNumberread-onlycurrentLast Line which generates a trap
1.3.6.1.4.1.20044.42.10.4ScalarpmapctrapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.42.10.30NotificationpmapcLas2TrapNotUrgentGoesOncurrentNot urgent Line default is activated
1.3.6.1.4.1.20044.42.10.31NotificationpmapcLas2TrapNotUrgentGoesOffcurrentNot urgent Line default disappeared
1.3.6.1.4.1.20044.42.10.32NotificationpmapcLas2TrapUrgentGoesOncurrentUrgent Line default is activated
1.3.6.1.4.1.20044.42.10.33NotificationpmapcLas2TrapUrgentGoesOffcurrentUrgent Line default disappeared
1.3.6.1.4.1.20044.42.10.34NotificationpmapcLas2TrapCritGoesOncurrentCritical Line default is activated
1.3.6.1.4.1.20044.42.10.35NotificationpmapcLas2TrapCritGoesOffcurrentCritical Line default disappeared
1.3.6.1.4.1.20044.42.10.40NotificationpmapcLas1TrapNotUrgentGoesOncurrentNot urgent client default is activated
1.3.6.1.4.1.20044.42.10.41NotificationpmapcLas1TrapNotUrgentGoesOffcurrentNot urgent client default disappeared
1.3.6.1.4.1.20044.42.10.42NotificationpmapcLas1TrapUrgentGoesOncurrentUrgent client default is activated
1.3.6.1.4.1.20044.42.10.43NotificationpmapcLas1TrapUrgentGoesOffcurrentUrgent client default disappeared
1.3.6.1.4.1.20044.42.10.44NotificationpmapcLas1TrapCritGoesOncurrentCritical client default is activated
1.3.6.1.4.1.20044.42.10.45NotificationpmapcLas1TrapCritGoesOffcurrentCritical client default disappeared
1.3.6.1.4.1.20044.42.10.50NotificationpmapcPowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.42.10.51NotificationpmapcPowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared