MIB Viewer

EKINOPS-Pmc1008MP-MIB

896 objects
MIB for managing Ekinops modules with PM1008MP software
OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.47IdentitymodulePmc1008mpMIB for managing Ekinops modules with PM1008MP software
1.3.6.1.4.1.20044.47.2Nodepmc1008mpalarms
1.3.6.1.4.1.20044.47.2.1Nodepmc1008mpAlmOther
1.3.6.1.4.1.20044.47.2.1.1Nodepmc1008mpAlmOtherNurg
1.3.6.1.4.1.20044.47.2.1.1.2Nodepmc1008mpAlmsynthAlm2
1.3.6.1.4.1.20044.47.2.1.1.2.1Scalarpmc1008mpAlmConfTableSaveread-onlycurrentPM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> other…
1.3.6.1.4.1.20044.47.2.1.1.2.2Scalarpmc1008mpAlmInvUploadread-onlycurrentInventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> other (1) <Alarmtype> other (1) <Polarit…
1.3.6.1.4.1.20044.47.2.1.1.2.3Scalarpmc1008mpAlmConfTableLoadread-onlycurrentPM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> other (1) <Alarmt…
1.3.6.1.4.1.20044.47.2.1.1.2.4Scalarpmc1008mpAlmCorrelatOffread-onlycurrentNot Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> other (1) <Alarmtype> other (1) <Pol…
1.3.6.1.4.1.20044.47.2.1.2Nodepmc1008mpAlmOtherUrg
1.3.6.1.4.1.20044.47.2.1.2.194Nodepmc1008mpAlmmodInitFailLevel2
1.3.6.1.4.1.20044.47.2.1.2.194.1Scalarpmc1008mpAlmLedFailread-onlycurrentLed Fail :This OID indicates that Led register has not been correctly initalized <Help> This alarm indicates if the module LEDs are correctly initialized <Cond…
1.3.6.1.4.1.20044.47.2.1.2.194.2Scalarpmc1008mpAlmNextColdBootForcedread-onlycurrentNext Cold Boot Forced :This OID indicates that the next Reset will be forced Cold <Help> This alarm indicates that the next reset of the module will be forced …
1.3.6.1.4.1.20044.47.2.1.2.194.3Scalarpmc1008mpAlmBootUndoneread-onlycurrentBoot Undone :This OID indicates that the boot has not been correctly achieved <Help> This alarm indicates if the module has correctly boot <Condtype> BOOT_UNDO…
1.3.6.1.4.1.20044.47.2.1.2.194.4Scalarpmc1008mpAlmResetHwInitFailread-onlycurrentReset HW Init Fail :This OID indicates that the HW intialization has caused unknown intial conditions <Help> This alarm indicates if the HW has been correctly …
1.3.6.1.4.1.20044.47.2.1.2.194.5Scalarpmc1008mpAlmSwInitFailread-onlycurrentSW Init Fail :This OID indicates that the SW intialization has caused unknown intial conditions <Help> This alarm indicates if the SW module is correctly initi…
1.3.6.1.4.1.20044.47.2.1.2.195Nodepmc1008mpAlmmodInitFailLevel3
1.3.6.1.4.1.20044.47.2.1.2.195.1Scalarpmc1008mpAlmGwIdentFailread-onlycurrentGW Ident Fail :This OID indicates that GW identification has not been read <Help> This alarm indicates if the GW has been correctly identified <Condtype> GW_ID…
1.3.6.1.4.1.20044.47.2.1.2.195.2Scalarpmc1008mpAlmObmTypeReadFailread-onlycurrentOBM Type Read Fail :This OID indicates that OBM type has not been recognized <Help> This alarm indicates if the OBM board has been correctly identified <Condty…
1.3.6.1.4.1.20044.47.2.1.2.195.3Scalarpmc1008mpAlmInitModuleFailread-onlycurrentInit Module Fail :This OID indicates that the Module has not been correctly initialized <Help> This alarm indicates if the SW module is correctly initialized <…
1.3.6.1.4.1.20044.47.2.1.2.195.5Scalarpmc1008mpAlmXfp1InitFailread-onlycurrentXFP1 Init Fail :This OID indicates that the XFP has not been correctly initialized <Help> This alarm indicates if the line transceiver 1 is correctly initializ…
1.3.6.1.4.1.20044.47.2.1.2.195.6Scalarpmc1008mpAlmXfp2InitFailread-onlycurrentXFP2 Init Fail :This OID indicates that the XFP has not been correctly initialized <Help> This alarm indicates if the line transceiver 2 is correctly initializ…
1.3.6.1.4.1.20044.47.2.1.2.195.7Scalarpmc1008mpAlmLine1InitFailread-onlycurrentLine1 Init Fail :This OID indicates that the Line registersvsubset has not been correctly initialized <Help> This alarm indicates if the line port 1 is correct…
1.3.6.1.4.1.20044.47.2.1.2.195.8Scalarpmc1008mpAlmLine2InitFailread-onlycurrentLine2 Init Fail :This OID indicates that the Line register subset has not been correctly initialized <Help> This alarm indicates if the line port 2 is correctl…
1.3.6.1.4.1.20044.47.2.1.2.195.9Scalarpmc1008mpAlmClient1InitFailread-onlycurrentClient1 Init Fail :This OID indicates that Client 1 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 1 is cor…
1.3.6.1.4.1.20044.47.2.1.2.195.10Scalarpmc1008mpAlmClient2InitFailread-onlycurrentClient2 Init Fail :This OID indicates that Client 2 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 2 is cor…
1.3.6.1.4.1.20044.47.2.1.2.195.11Scalarpmc1008mpAlmClient3InitFailread-onlycurrentClient3 Init Fail :This OID indicates that Client 3 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 3 is cor…
1.3.6.1.4.1.20044.47.2.1.2.195.12Scalarpmc1008mpAlmClient4InitFailread-onlycurrentClient4 Init Fail :This OID indicates that Client 4 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 4 is cor…
1.3.6.1.4.1.20044.47.2.1.2.195.13Scalarpmc1008mpAlmClient5InitFailread-onlycurrentClient5 Init Fail :This OID indicates that Client 5 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 5 is cor…
1.3.6.1.4.1.20044.47.2.1.2.195.14Scalarpmc1008mpAlmClient6InitFailread-onlycurrentClient6 Init Fail :This OID indicates that Client 6 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 6 is cor…
1.3.6.1.4.1.20044.47.2.1.2.195.15Scalarpmc1008mpAlmClient7InitFailread-onlycurrentClient7 Init Fail :This OID indicates that Client 7 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 7 is cor…
1.3.6.1.4.1.20044.47.2.1.2.195.16Scalarpmc1008mpAlmClient8InitFailread-onlycurrentClient8 Init Fail :This OID indicates that Client 8 registers subset has not been correctly initialized <Help> This alarm indicates if the client port 8 is cor…
1.3.6.1.4.1.20044.47.2.1.2.198Nodepmc1008mpAlmadddropTsClientRxProt
1.3.6.1.4.1.20044.47.2.1.2.198.1Scalarpmc1008mpAlmAdddropClient1Westread-onlycurrentClient 1 West Rx Side Active :This OID indicates the Client #1 is active on West receiving side <Condtype> ADDDROP_CLIENT1_WEST <Probcause> other (1) <Alarmtyp…
1.3.6.1.4.1.20044.47.2.1.2.198.2Scalarpmc1008mpAlmAdddropClient2Westread-onlycurrentClient 2 West Rx Side Active :This OID indicates the Client #2 is active on West receiving side <Condtype> ADDDROP_CLIENT2_WEST <Probcause> other (1) <Alarmtyp…
1.3.6.1.4.1.20044.47.2.1.2.198.3Scalarpmc1008mpAlmAdddropClient3Westread-onlycurrentClient 3 West Rx Side Active :This OID indicates the Client #3 is active on West receiving side <Condtype> ADDDROP_CLIENT3_WEST <Probcause> other (1) <Alarmtyp…
1.3.6.1.4.1.20044.47.2.1.2.198.4Scalarpmc1008mpAlmAdddropClient4Westread-onlycurrentClient 4 West Rx Side Active :This OID indicates the Client #4 is active on West receiving side <Condtype> ADDDROP_CLIENT4_WEST <Probcause> other (1) <Alarmtyp…
1.3.6.1.4.1.20044.47.2.1.2.198.5Scalarpmc1008mpAlmAdddropClient5Westread-onlycurrentClient 5 West Rx Side Active :This OID indicates the Client #5 is active on West receiving side <Condtype> ADDDROP_CLIENT5_WEST <Probcause> other (1) <Alarmtyp…
1.3.6.1.4.1.20044.47.2.1.2.198.6Scalarpmc1008mpAlmAdddropClient6Westread-onlycurrentClient 6 West Rx Side Active :This OID indicates the Client #6 is active on West receiving side <Condtype> ADDDROP_CLIENT6_WEST <Probcause> other (1) <Alarmtyp…
1.3.6.1.4.1.20044.47.2.1.2.198.7Scalarpmc1008mpAlmAdddropClient7Westread-onlycurrentClient 7 West Rx Side Active :This OID indicates the Client #7 is active on West receiving side <Condtype> ADDDROP_CLIENT7_WEST <Probcause> other (1) <Alarmtyp…
1.3.6.1.4.1.20044.47.2.1.2.198.8Scalarpmc1008mpAlmAdddropClient8Westread-onlycurrentClient 8 West Rx Side Active :This OID indicates the Client #8 is active on West receiving side <Condtype> ADDDROP_CLIENT8_WEST <Probcause> other (1) <Alarmtyp…
1.3.6.1.4.1.20044.47.2.1.2.198.9Scalarpmc1008mpAlmAdddropClient1Eastread-onlycurrentClient 1 East Rx Side Active :This OID indicates the Client #1 is active on East receiving side <Condtype> ADDDROP_CLIENT1_EAST <Probcause> other (1) <Alarmtyp…
1.3.6.1.4.1.20044.47.2.1.2.198.10Scalarpmc1008mpAlmAdddropClient2Eastread-onlycurrentClient 2 East Rx Side Active :This OID indicates the Client #2 is active on East receiving side <Condtype> ADDDROP_CLIENT2_EAST <Probcause> other (1) <Alarmtyp…
1.3.6.1.4.1.20044.47.2.1.2.198.11Scalarpmc1008mpAlmAdddropClient3Eastread-onlycurrentClient 3 East Rx Side Active :This OID indicates the Client #3 is active on East receiving side <Condtype> ADDDROP_CLIENT3_EAST <Probcause> other (1) <Alarmtyp…
1.3.6.1.4.1.20044.47.2.1.2.198.12Scalarpmc1008mpAlmAdddropClient4Eastread-onlycurrentClient 4 East Rx Side Active :This OID indicates the Client #4 is active on East receiving side <Condtype> ADDDROP_CLIENT4_EAST <Probcause> other (1) <Alarmtyp…
1.3.6.1.4.1.20044.47.2.1.2.198.13Scalarpmc1008mpAlmAdddropClient5Eastread-onlycurrentClient 5 East Rx Side Active :This OID indicates the Client #5 is active on East receiving side <Condtype> ADDDROP_CLIENT5_EAST <Probcause> other (1) <Alarmtyp…
1.3.6.1.4.1.20044.47.2.1.2.198.14Scalarpmc1008mpAlmAdddropClient6Eastread-onlycurrentClient 6 East Rx Side Active :This OID indicates the Client #6 is active on East receiving side <Condtype> ADDDROP_CLIENT6_EAST <Probcause> other (1) <Alarmtyp…
1.3.6.1.4.1.20044.47.2.1.2.198.15Scalarpmc1008mpAlmAdddropClient7Eastread-onlycurrentClient 7 East Rx Side Active :This OID indicates the Client #7 is active on East receiving side <Condtype> ADDDROP_CLIENT7_EAST <Probcause> other (1) <Alarmtyp…
1.3.6.1.4.1.20044.47.2.1.2.198.16Scalarpmc1008mpAlmAdddropClient8Eastread-onlycurrentClient 8 East Rx Side Active :This OID indicates the Client #8 is active on East receiving side <Condtype> ADDDROP_CLIENT8_EAST <Probcause> other (1) <Alarmtyp…
1.3.6.1.4.1.20044.47.2.1.3Nodepmc1008mpAlmOtherCrit
1.3.6.1.4.1.20044.47.2.1.3.0Nodepmc1008mpAlmsynthAlm0
1.3.6.1.4.1.20044.47.2.1.3.0.9Scalarpmc1008mpAlmModGlobFailread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the PM <Condtype> MOD_GLOB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> sy…
1.3.6.1.4.1.20044.47.2.1.3.0.15Scalarpmc1008mpAlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.47.2.1.3.0.16Scalarpmc1008mpAlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.47.2.2Nodepmc1008mpAlmClient
1.3.6.1.4.1.20044.47.2.2.1Nodepmc1008mpAlmClientNurg
1.3.6.1.4.1.20044.47.2.2.1.48Tablepmc1008mpAlmsfpWarnDdmTablenot-accessiblecurrentList of pmc1008mpAlmsfpWarnDdm Article
1.3.6.1.4.1.20044.47.2.2.1.48.1Rowpmc1008mpAlmsfpWarnDdmEntrynot-accessiblecurrentRow definition for the pmc1008mpAlmsfpWarnDdm table
1.3.6.1.4.1.20044.47.2.2.1.48.1.1Columnpmc1008mpAlmsfpWarnDdmIndexread-onlycurrentIndex definition for the pmc1008mpAlmsfpWarnDdm table
1.3.6.1.4.1.20044.47.2.2.1.48.1.2Columnpmc1008mpAlmTxPwLowWngPortnread-onlycurrentClient SFP Tx Power Low Warning :Warning indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> TX…
1.3.6.1.4.1.20044.47.2.2.1.48.1.3Columnpmc1008mpAlmTxPwrHighWngPortnread-onlycurrentClient SFP Tx Power High Warning :Warning indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.47.2.2.1.48.1.4Columnpmc1008mpAlmTxBiasLowWngPortnread-onlycurrentClient SFP Bias Low Warning :Warning indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.47.2.2.1.48.1.5Columnpmc1008mpAlmTxBiasHighWngPortnread-onlycurrentClient SFP Bias High Warning :Warning indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.47.2.2.1.48.1.6Columnpmc1008mpAlmVccLowWngPortnread-onlycurrentClient SFP Power Supply Low Warning :Warning indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.47.2.2.1.48.1.7Columnpmc1008mpAlmVccHighWngPortnread-onlycurrentClient SFP Power Supply High Warning :Warning indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condty…
1.3.6.1.4.1.20044.47.2.2.1.48.1.8Columnpmc1008mpAlmTempLowWngPortnread-onlycurrentClient SFP Temp Low Warning :Warning indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> TEMP_LO…
1.3.6.1.4.1.20044.47.2.2.1.48.1.9Columnpmc1008mpAlmTempHighWngPortnread-onlycurrentClient SFP Temp High Warning :Warning indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> TEMP_…
1.3.6.1.4.1.20044.47.2.2.1.48.1.16Columnpmc1008mpAlmRxPwrLowWngPortnread-onlycurrentClient SFP Rx Power Low Warning :Warning indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> RX_…
1.3.6.1.4.1.20044.47.2.2.1.48.1.17Columnpmc1008mpAlmRxPwrHighWngPortnread-onlycurrentClient SFP Rx Power High Warning :Warning indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> R…
1.3.6.1.4.1.20044.47.2.2.2Nodepmc1008mpAlmClientUrg
1.3.6.1.4.1.20044.47.2.2.2.32Tablepmc1008mpAlmsfpAlmDdmTablenot-accessiblecurrentList of pmc1008mpAlmsfpAlmDdm Article
1.3.6.1.4.1.20044.47.2.2.2.32.1Rowpmc1008mpAlmsfpAlmDdmEntrynot-accessiblecurrentRow definition for the pmc1008mpAlmsfpAlmDdm table
1.3.6.1.4.1.20044.47.2.2.2.32.1.1Columnpmc1008mpAlmsfpAlmDdmIndexread-onlycurrentIndex definition for the pmc1008mpAlmsfpAlmDdm table
1.3.6.1.4.1.20044.47.2.2.2.32.1.2Columnpmc1008mpAlmTxPwrLowAlaPortnread-onlycurrentClient SFP Tx Power Low :Alarm indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> TX_PWR_LOW_A…
1.3.6.1.4.1.20044.47.2.2.2.32.1.3Columnpmc1008mpAlmTxPwrHighAlaPortnread-onlycurrentClient SFP Tx Power High :Alarm indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> TX_PWR_HIG…
1.3.6.1.4.1.20044.47.2.2.2.32.1.4Columnpmc1008mpAlmTxBiasLowAlaPortnread-onlycurrentClient SFP Bias Low :Alarm indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> TX_BIAS_LO…
1.3.6.1.4.1.20044.47.2.2.2.32.1.5Columnpmc1008mpAlmTxBiasHighAlaPortnread-onlycurrentClient SFP Bias High :Alarm indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype> TX_BIAS_…
1.3.6.1.4.1.20044.47.2.2.2.32.1.6Columnpmc1008mpAlmVccLowAlaPortnread-onlycurrentClient SFP Power Supply Low :Alarm indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype> VCC_LOW_…
1.3.6.1.4.1.20044.47.2.2.2.32.1.7Columnpmc1008mpAlmVccHighAlaPortnread-onlycurrentClient SFP Power Supply High :Alarm indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condtype> VCC_HI…
1.3.6.1.4.1.20044.47.2.2.2.32.1.8Columnpmc1008mpAlmTempLowAlaPortnread-onlycurrentClient SFP Temp Low :Alarm indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> TEMP_LOW_ALA_1 <P…
1.3.6.1.4.1.20044.47.2.2.2.32.1.9Columnpmc1008mpAlmTempHighAlaPortnread-onlycurrentClient SFP Temp High :Alarm indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> TEMP_HIGH_ALA_1…
1.3.6.1.4.1.20044.47.2.2.2.32.1.16Columnpmc1008mpAlmRxPwrLowAlaPortnread-onlycurrentClient SFP Rx Power Low :Alarm indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> RX_PWR_LOW_AL…
1.3.6.1.4.1.20044.47.2.2.2.32.1.17Columnpmc1008mpAlmRxPwrHighAlaPortnread-onlycurrentClient SFP Rx Power High :Alarm indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> RX_PWR_HIGH…
1.3.6.1.4.1.20044.47.2.2.3Nodepmc1008mpAlmClientCrit
1.3.6.1.4.1.20044.47.2.2.3.8Tablepmc1008mpAlmsynthAlmPortTablenot-accessiblecurrentList of pmc1008mpAlmsynthAlmPort Article
1.3.6.1.4.1.20044.47.2.2.3.8.1Rowpmc1008mpAlmsynthAlmPortEntrynot-accessiblecurrentRow definition for the pmc1008mpAlmsynthAlmPort table
1.3.6.1.4.1.20044.47.2.2.3.8.1.1Columnpmc1008mpAlmsynthAlmPortIndexread-onlycurrentIndex definition for the pmc1008mpAlmsynthAlmPort table
1.3.6.1.4.1.20044.47.2.2.3.8.1.2Columnpmc1008mpAlmSfpAbsentPortnread-onlycurrentClient SFP Absent :This OID indicates that the SFP module is not present in the client port. <Help> This alarm indicates if the client transceiver is present. …
1.3.6.1.4.1.20044.47.2.2.3.8.1.3Columnpmc1008mpAlmDdmAbsentPortnread-onlycurrentDDM Supported On Client SFP :This OID indicates that the Client SFP module supports the Digital Diagnostic Monitoring function <Help> This status indicates if …
1.3.6.1.4.1.20044.47.2.2.3.8.1.5Columnpmc1008mpAlmHwFailAccPortnread-onlycurrentClient HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Condtype> HW_FAIL_ACC_1 <Probcause> equipmentMalfunction (16)…
1.3.6.1.4.1.20044.47.2.2.3.8.1.6Columnpmc1008mpAlmDwLsdPortnread-onlycurrentClient SFP Laser Shutdown :This OID indicates the Client SFP transmitter output is ON. <Help> This status indicates if the client transceiver laser is ON or OF…
1.3.6.1.4.1.20044.47.2.2.3.8.1.7Columnpmc1008mpAlmClientLocalOosPortnread-onlycurrentLocal Client Port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local c…
1.3.6.1.4.1.20044.47.2.2.3.8.1.8Columnpmc1008mpAlmClientRemoteOosPortnread-onlycurrentRemote Client Port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the remot…
1.3.6.1.4.1.20044.47.2.2.3.8.1.9Columnpmc1008mpAlmDwCaisPortnread-onlycurrentClient AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indicates if a Client Alarm Indication Signal is…
1.3.6.1.4.1.20044.47.2.2.3.8.1.10Columnpmc1008mpAlmSfpDdmWarningPortnread-onlycurrentWarning On Client SFP DDM :This OID indicates a warning is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Warning has been detecte…
1.3.6.1.4.1.20044.47.2.2.3.8.1.11Columnpmc1008mpAlmSfpDdmAlmPortnread-onlycurrentAlarm On Client SFP DDM :This OID indicates an alarm is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Alarm has been detected on …
1.3.6.1.4.1.20044.47.2.2.3.8.1.13Columnpmc1008mpAlmFailAccPortnread-onlycurrentClient Access Fail :This OID indicates a failure on the Client port <Condtype> FAIL_ACC_1 <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12)…
1.3.6.1.4.1.20044.47.2.2.3.8.1.16Columnpmc1008mpAlmClientActivePortnread-onlycurrentClient Sink (Line1 Or Line2) :This bit indicates the Client #n is active on receive side <Help> This status indicates whether the Client is extracted from Line…
1.3.6.1.4.1.20044.47.2.2.3.8.1.17Columnpmc1008mpAlmUpCsfPortnread-onlycurrentClient Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu…
1.3.6.1.4.1.20044.47.2.2.3.16Tablepmc1008mpAlmaccessioAlmTablenot-accessiblecurrentList of pmc1008mpAlmaccessioAlm Article
1.3.6.1.4.1.20044.47.2.2.3.16.1Rowpmc1008mpAlmaccessioAlmEntrynot-accessiblecurrentRow definition for the pmc1008mpAlmaccessioAlm table
1.3.6.1.4.1.20044.47.2.2.3.16.1.1Columnpmc1008mpAlmaccessioAlmIndexread-onlycurrentIndex definition for the pmc1008mpAlmaccessioAlm table
1.3.6.1.4.1.20044.47.2.2.3.16.1.2Columnpmc1008mpAlmDwLasFailPortnread-onlycurrentClient SFP Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the client port (this alarm reports the transmitter failure alarm …
1.3.6.1.4.1.20044.47.2.2.3.16.1.5Columnpmc1008mpAlmUpLosPortnread-onlycurrentClient Input Loss Of Signal :This OID indicates that no signal is present on the SFP of the client port <Help> This alarm indicates if an optical signal is det…
1.3.6.1.4.1.20044.47.2.2.3.72Tablepmc1008mpAlmmapperDeAlmTablenot-accessiblecurrentList of pmc1008mpAlmmapperDeAlm Article
1.3.6.1.4.1.20044.47.2.2.3.72.1Rowpmc1008mpAlmmapperDeAlmEntrynot-accessiblecurrentRow definition for the pmc1008mpAlmmapperDeAlm table
1.3.6.1.4.1.20044.47.2.2.3.72.1.1Columnpmc1008mpAlmmapperDeAlmIndexread-onlycurrentIndex definition for the pmc1008mpAlmmapperDeAlm table
1.3.6.1.4.1.20044.47.2.2.3.72.1.2Columnpmc1008mpAlmUpAccOosPortnread-onlycurrentClient Loss Of Synchro :This OID indicates the upstream client input port has lost synchronization on its decoder <Help> This alarms indicates if the input cli…
1.3.6.1.4.1.20044.47.2.2.3.72.1.11Columnpmc1008mpAlmUpBufferOvlPortnread-onlycurrentClient Upstream Buffer Overload :This OID indicates that the rate adaptation buffer for client port is in overload. <Help> This alarm indicates if there is a u…
1.3.6.1.4.1.20044.47.2.2.3.72.1.12Columnpmc1008mpAlmDwCsfDetPortnread-onlycurrentClient Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client…
1.3.6.1.4.1.20044.47.2.2.3.72.1.15Columnpmc1008mpAlmDwBufferOvlPortnread-onlycurrentClient Downstream Buffer Overload :This OID indicates that the de-mapper buffer for client port is in overload. <Help> This alarm indicates if there is a downs…
1.3.6.1.4.1.20044.47.2.3Nodepmc1008mpAlmLine
1.3.6.1.4.1.20044.47.2.3.1Nodepmc1008mpAlmLineNurg
1.3.6.1.4.1.20044.47.2.3.1.209Tablepmc1008mpAlmlineXfp1WarningsTablenot-accessiblecurrentList of pmc1008mpAlmlineXfp1Warnings Article
1.3.6.1.4.1.20044.47.2.3.1.209.1Rowpmc1008mpAlmlineXfp1WarningsEntrynot-accessiblecurrentRow definition for the pmc1008mpAlmlineXfp1Warnings table
1.3.6.1.4.1.20044.47.2.3.1.209.1.1Columnpmc1008mpAlmlineXfp1WarningsIndexread-onlycurrentIndex definition for the pmc1008mpAlmlineXfp1Warnings table
1.3.6.1.4.1.20044.47.2.3.1.209.1.2Columnpmc1008mpAlmTxPowerLowWarningPortnread-onlycurrentLine Optical Tx Power Low Warning :Warning indicating that the XFP/OTX transmitter transmitter output power is lower than the threshold value written in the XF…
1.3.6.1.4.1.20044.47.2.3.1.209.1.3Columnpmc1008mpAlmTxPowerHighWarningPortnread-onlycurrentLine Optical Tx Power High Warning :Warning indicating that the XFP/OTX transmitter transmitter output power is higher than the threshold value written in the …
1.3.6.1.4.1.20044.47.2.3.1.209.1.4Columnpmc1008mpAlmTxBiasLowWarningPortnread-onlycurrentLine Transceiver Bias Low Warning :Warning indicating that the XFP/OTX transmitter laser bias current is lower than the threshold value written in the XFP/OTX …
1.3.6.1.4.1.20044.47.2.3.1.209.1.5Columnpmc1008mpAlmTxBiasHighWarningPortnread-onlycurrentLine Transceiver Bias High Warning :Warning indicating that the XFP/OTX transmitter laser bias current is higher than the threshold value written in the XFP EE…
1.3.6.1.4.1.20044.47.2.3.1.209.1.8Columnpmc1008mpAlmTempLowWarningPortnread-onlycurrentLine Transceiver Temp Low Warning :Warning indicating that the XFP/OTX temperature is lower than the threshold value written in the XFP/OTX EEPROM <Condtype> T…
1.3.6.1.4.1.20044.47.2.3.1.209.1.9Columnpmc1008mpAlmTempHighWarningPortnread-onlycurrentLine Transceiver Temp High Warning :Warning indicating that the XFP/OTX temperature is higher than the threshold value written in the XFP EEPROM <Condtype> TEM…
1.3.6.1.4.1.20044.47.2.3.1.209.1.16Columnpmc1008mpAlmRxPowerLowWarningPortnread-onlycurrentLine Optical Rx Power Low Warning :Warning indicating that the XFP received optical power is lower than the threshold value written in the XFP EEPROM <Condtype…
1.3.6.1.4.1.20044.47.2.3.1.209.1.17Columnpmc1008mpAlmRxPowerHighWarningPortnread-onlycurrentLine Optical Rx Power High Warning :Warning indicating that the XFP received optical power is higher than the threshold value written in the XFP EEPROM <Condty…
1.3.6.1.4.1.20044.47.2.3.1.225Tablepmc1008mpAlmlineOtx1TlhWarningsTablenot-accessiblecurrentList of pmc1008mpAlmlineOtx1TlhWarnings Article
1.3.6.1.4.1.20044.47.2.3.1.225.1Rowpmc1008mpAlmlineOtx1TlhWarningsEntrynot-accessiblecurrentRow definition for the pmc1008mpAlmlineOtx1TlhWarnings table
1.3.6.1.4.1.20044.47.2.3.1.225.1.1Columnpmc1008mpAlmlineOtx1TlhWarningsIndexread-onlycurrentIndex definition for the pmc1008mpAlmlineOtx1TlhWarnings table
1.3.6.1.4.1.20044.47.2.3.1.225.1.6Columnpmc1008mpAlmLineModulatorAgingHighWarningPortnread-onlycurrentLine Modulator Aging High Warning :Warning indicating the Line OTX TLH modulator aging is higher than the threshold written in the EEPROM <Condtype> LINE_MODUL…
1.3.6.1.4.1.20044.47.2.3.1.225.1.7Columnpmc1008mpAlmLineAgingHighWarningPortnread-onlycurrentLine OTX TLH Aging High Warning :Warning indicating the Line OTX TLH aging is higher than the threshold written in the EEPROM <Condtype> LINE_AGING_HIGH_WARNIN…
1.3.6.1.4.1.20044.47.2.3.1.225.1.13Columnpmc1008mpAlmLineFreqDevHighWarningPortnread-onlycurrentLine Freq. Deviation High Warning :Warning indicating the Line OTX TLH frequency deviation is higher than the threshold written in the EEPROM <Condtype> LINE_F…
1.3.6.1.4.1.20044.47.2.3.1.225.1.15Columnpmc1008mpAlmLineLaserTempHighWarningPortnread-onlycurrentLine Laser Temp. High Warning :Warning indicating the Line OTX TLH laser temperature is higher than the threshold written in the EEPROM <Condtype> LINE_LASER_T…
1.3.6.1.4.1.20044.47.2.3.2Nodepmc1008mpAlmLineUrg
1.3.6.1.4.1.20044.47.2.3.2.129Tablepmc1008mpAlmdfrmBerTablenot-accessiblecurrentList of pmc1008mpAlmdfrmBer Article
1.3.6.1.4.1.20044.47.2.3.2.129.1Rowpmc1008mpAlmdfrmBerEntrynot-accessiblecurrentRow definition for the pmc1008mpAlmdfrmBer table
1.3.6.1.4.1.20044.47.2.3.2.129.1.1Columnpmc1008mpAlmdfrmBerIndexread-onlycurrentIndex definition for the pmc1008mpAlmdfrmBer table
1.3.6.1.4.1.20044.47.2.3.2.129.1.2Columnpmc1008mpAlmLineSignalDegradePortnread-onlycurrentCustom Line Signal Degrade :This OID indicates that the line input signal is DEGRADE. The assertion hysteresis can customized by the host <Condtype> LINE_SIGNA…
1.3.6.1.4.1.20044.47.2.3.2.129.1.3Columnpmc1008mpAlmLineSignalFailPortnread-onlycurrentCustom Line Signal Fail :This OID indicates that the line input signal is FAIL. The assertion hysteresis can be customized by the host <Condtype> LINE_SIGNAL_F…
1.3.6.1.4.1.20044.47.2.3.2.129.1.6Columnpmc1008mpAlmLineDegradePortnread-onlycurrentFixed Line Signal Degrade :This OID indicates that the line input signal is DEGRADE. The assetion hysteresis is fixed to 10-8 (assertion) and 10-9 (de-assertio…
1.3.6.1.4.1.20044.47.2.3.2.208Tablepmc1008mpAlmlineXfp1AlarmTablenot-accessiblecurrentList of pmc1008mpAlmlineXfp1Alarm Article
1.3.6.1.4.1.20044.47.2.3.2.208.1Rowpmc1008mpAlmlineXfp1AlarmEntrynot-accessiblecurrentRow definition for the pmc1008mpAlmlineXfp1Alarm table
1.3.6.1.4.1.20044.47.2.3.2.208.1.1Columnpmc1008mpAlmlineXfp1AlarmIndexread-onlycurrentIndex definition for the pmc1008mpAlmlineXfp1Alarm table
1.3.6.1.4.1.20044.47.2.3.2.208.1.2Columnpmc1008mpAlmTxPowerLowAlarmPortnread-onlycurrentLine Optical Tx Power Low :Alarm indicating that the XFP/OTX transmitter transmitter output power is lower than the threshold value written in the XFP/OTX EEPR…
1.3.6.1.4.1.20044.47.2.3.2.208.1.3Columnpmc1008mpAlmTxPowerHighAlarmPortnread-onlycurrentLine Optical Tx Power High :Alarm indicating that the XFP/OTX transmitter transmitter output power is higher than the threshold value written in the XFP EEPROM…
1.3.6.1.4.1.20044.47.2.3.2.208.1.4Columnpmc1008mpAlmTxBiasLowAlarmPortnread-onlycurrentLine Transceiver Bias Low :Alarm indicating that the XFP/OTX transmitter laser bias current is lower than the threshold value written in the XFP/OTX EEPROM <Co…
1.3.6.1.4.1.20044.47.2.3.2.208.1.5Columnpmc1008mpAlmTxBiasHighAlarmPortnread-onlycurrentLine Transceiver Bias High :Alarm indicating that the XFP/OTX transmitter laser bias current is higher than the threshold value written in the XFP EEPROM <Cond…
1.3.6.1.4.1.20044.47.2.3.2.208.1.8Columnpmc1008mpAlmTempLowAlarmPortnread-onlycurrentLine Transceiver Temp Low :Alarm indicating that the XFP/OTX temperature is lower than the threshold value written in the XFP/OTX EEPROM <Condtype> TEMP_LOW_AL…
1.3.6.1.4.1.20044.47.2.3.2.208.1.9Columnpmc1008mpAlmTempHighAlarmPortnread-onlycurrentLine Transceiver Temp High :Alarm indicating that the XFP/OTX temperature is higher than the threshold value written in the XFP EEPROM <Condtype> TEMP_HIGH_ALA…
1.3.6.1.4.1.20044.47.2.3.2.208.1.16Columnpmc1008mpAlmRxPowerLowAlarmPortnread-onlycurrentLine Optical Rx Power Low :Alarm indicating that the XFP received optical power is lower than the threshold value written in the XFP EEPROM <Condtype> RX_POWER…
1.3.6.1.4.1.20044.47.2.3.2.208.1.17Columnpmc1008mpAlmRxPowerHighAlarmPortnread-onlycurrentLine Optical Rx Power High :Alarm indicating that the XFP received optical power is higher than the threshold value written in the XFP EEPROM <Condtype> RX_POW…
1.3.6.1.4.1.20044.47.2.3.2.212Tablepmc1008mpAlmlineXfp1SupplyAlarmTablenot-accessiblecurrentList of pmc1008mpAlmlineXfp1SupplyAlarm Article
1.3.6.1.4.1.20044.47.2.3.2.212.1Rowpmc1008mpAlmlineXfp1SupplyAlarmEntrynot-accessiblecurrentRow definition for the pmc1008mpAlmlineXfp1SupplyAlarm table
1.3.6.1.4.1.20044.47.2.3.2.212.1.1Columnpmc1008mpAlmlineXfp1SupplyAlarmIndexread-onlycurrentIndex definition for the pmc1008mpAlmlineXfp1SupplyAlarm table
1.3.6.1.4.1.20044.47.2.3.2.212.1.2Columnpmc1008mpAlmVee5LowAlarmPortnread-onlycurrentVEE5 Power Supply Low :Alarm indicating the XFP/OTX VEE5 power supply is lower than the threshold written in the EEPROM <Condtype> VEE5_LOW_ALARM_1 <Probcause>…
1.3.6.1.4.1.20044.47.2.3.2.212.1.3Columnpmc1008mpAlmVee5HighAlarmPortnread-onlycurrentVEE5 Power Supply High :Alarm indicating the XFP/OTX VEE5 power supply is higher than the threshold written in the EEPROM <Condtype> VEE5_HIGH_ALARM_1 <Probcau…
1.3.6.1.4.1.20044.47.2.3.2.212.1.4Columnpmc1008mpAlmVcc2LowAlarmPortnread-onlycurrentVCC2 Power Supply Low :Alarm indicating the XFP/OTX VCC2 power supply is lower than the threshold written in the EEPROM <Condtype> VCC2_LOW_ALARM_1 <Probcause>…
1.3.6.1.4.1.20044.47.2.3.2.212.1.5Columnpmc1008mpAlmVcc2HighAlarmPortnread-onlycurrentVCC2 Power Supply High :Alarm indicating the XFP/OTX VCC2 power supply is higher than the threshold written in the EEPROM <Condtype> VCC2_HIGH_ALARM_1 <Probcau…
1.3.6.1.4.1.20044.47.2.3.2.212.1.6Columnpmc1008mpAlmVcc3LowAlarmPortnread-onlycurrentVCC3 Power Supply Low :Alarm indicating the XFP/OTX VCC3 power supply is lower than the threshold written in the EEPROM <Condtype> VCC3_LOW_ALARM_1 <Probcause>…
1.3.6.1.4.1.20044.47.2.3.2.212.1.7Columnpmc1008mpAlmVcc3HighAlarmPortnread-onlycurrentVCC3 Power Supply High :Alarm indicating the XFP/OTX VCC3 power supply is higher than the threshold written in the EEPROM <Condtype> VCC3_HIGH_ALARM_1 <Probcau…
1.3.6.1.4.1.20044.47.2.3.2.212.1.8Columnpmc1008mpAlmVcc5LowAlarmPortnread-onlycurrentVCC5 Power Supply Low :Alarm indicating the XFP/OTX VCC5 power supply is lower than the threshold written in the EEPROM <Condtype> VCC5_LOW_ALARM_1 <Probcause>…
1.3.6.1.4.1.20044.47.2.3.2.212.1.9Columnpmc1008mpAlmVcc5HighAlarmPortnread-onlycurrentVCC5 Power Supply High :Alarm indicating the XFP/OTX VCC5 power supply is higher than the threshold written in the EEPROM <Condtype> VCC5_HIGH_ALARM_1 <Probcau…
1.3.6.1.4.1.20044.47.2.3.2.212.1.10Columnpmc1008mpAlmVee5LowWarningPortnread-onlycurrentVEE5 Power Supply Low Warning :Warning indicating the XFP/OTX VEE5 power supply is lower than the threshold written in the EEPROM <Condtype> VEE5_LOW_WARNING_1…
1.3.6.1.4.1.20044.47.2.3.2.212.1.11Columnpmc1008mpAlmVee5HighWarningPortnread-onlycurrentVEE5 Power Supply High Warning :Warning indicating the XFP/OTX VEE5 power supply is higher than the threshold written in the EEPROM <Condtype> VEE5_HIGH_WARNIN…
1.3.6.1.4.1.20044.47.2.3.2.212.1.12Columnpmc1008mpAlmVcc2LowWarningPortnread-onlycurrentVCC2 Power Supply Low Warning :Warning indicating the XFP/OTX VCC2 power supply is lower than the threshold written in the EEPROM <Condtype> VCC2_LOW_WARNING_1…
1.3.6.1.4.1.20044.47.2.3.2.212.1.13Columnpmc1008mpAlmVcc2HighWarningPortnread-onlycurrentVCC2 Power Supply High Warning :Warning indicating the XFP/OTX VCC2 power supply is higher than the threshold written in the EEPROM <Condtype> VCC2_HIGH_WARNIN…
1.3.6.1.4.1.20044.47.2.3.2.212.1.14Columnpmc1008mpAlmVcc3LowWarningPortnread-onlycurrentVCC3 Power Supply Low Warning :Warning indicating the XFP/OTX VCC3 power supply is lower than the threshold written in the EEPROM <Condtype> VCC3_LOW_WARNING_1…
1.3.6.1.4.1.20044.47.2.3.2.212.1.15Columnpmc1008mpAlmVcc3HighWarningPortnread-onlycurrentVCC3 Power Supply High Warning :Warning indicating the XFP/OTX VCC3 power supply is higher than the threshold written in the EEPROM <Condtype> VCC3_HIGH_WARNIN…
1.3.6.1.4.1.20044.47.2.3.2.212.1.16Columnpmc1008mpAlmVcc5LowWarningPortnread-onlycurrentVCC5 Power Supply Low Warning :Warning indicating the XFP/OTX VCC5 power supply is lower than the threshold written in the EEPROM <Condtype> VCC5_LOW_WARNING_1…
1.3.6.1.4.1.20044.47.2.3.2.212.1.17Columnpmc1008mpAlmVcc5HighWarningPortnread-onlycurrentVCC5 Power Supply High Warning :Warning indicating the XFP/OTX VCC5 power supply is higher than the threshold written in the EEPROM <Condtype> VCC5_HIGH_WARNIN…
1.3.6.1.4.1.20044.47.2.3.2.224Tablepmc1008mpAlmlineOtx1TlhAlarmsTablenot-accessiblecurrentList of pmc1008mpAlmlineOtx1TlhAlarms Article
1.3.6.1.4.1.20044.47.2.3.2.224.1Rowpmc1008mpAlmlineOtx1TlhAlarmsEntrynot-accessiblecurrentRow definition for the pmc1008mpAlmlineOtx1TlhAlarms table
1.3.6.1.4.1.20044.47.2.3.2.224.1.1Columnpmc1008mpAlmlineOtx1TlhAlarmsIndexread-onlycurrentIndex definition for the pmc1008mpAlmlineOtx1TlhAlarms table
1.3.6.1.4.1.20044.47.2.3.2.224.1.6Columnpmc1008mpAlmLineModulatorAgingHighAlaPortnread-onlycurrentLine Modulator Aging High Alarm :Alarm indicating the Line OTX TLH modulator aging is higher than the threshold written in the EEPROM <Condtype> LINE_MODULATOR…
1.3.6.1.4.1.20044.47.2.3.2.224.1.7Columnpmc1008mpAlmLineAgingHighAlaPortnread-onlycurrentLine OTX TLH Aging High Alarm :Alarm indicating the Line OTX TLH aging is higher than the threshold written in the EEPROM <Condtype> LINE_AGING_HIGH_ALA_1 <Pro…
1.3.6.1.4.1.20044.47.2.3.2.224.1.10Columnpmc1008mpAlmLineCdrNotReadyPortnread-onlycurrentCDR Not Ready :This OID indicates the Clock Data Recovery unit is not yet initialized. <Help> This alarm indicates the Clock Data Recovery unit is not yet init…
1.3.6.1.4.1.20044.47.2.3.2.224.1.13Columnpmc1008mpAlmLineFreqDevHighAlaPortnread-onlycurrentLine Freq. Deviation High Alarm :Alarm indicating the Line OTX TLH frequency deviation is higher than the threshold written in the EEPROM <Condtype> LINE_FREQ_…
1.3.6.1.4.1.20044.47.2.3.2.224.1.15Columnpmc1008mpAlmLineLaserTempHighAlaPortnread-onlycurrentLine Laser Temp. High Alarm :Alarm indicating the Line OTX TLH laser temperature is higher than the threshold written in the EEPROM <Condtype> LINE_LASER_TEMP_…
1.3.6.1.4.1.20044.47.2.3.3Nodepmc1008mpAlmLineCrit
1.3.6.1.4.1.20044.47.2.3.3.7Tablepmc1008mpAlmsynthAlmLineTablenot-accessiblecurrentList of pmc1008mpAlmsynthAlmLine Article
1.3.6.1.4.1.20044.47.2.3.3.7.1Rowpmc1008mpAlmsynthAlmLineEntrynot-accessiblecurrentRow definition for the pmc1008mpAlmsynthAlmLine table
1.3.6.1.4.1.20044.47.2.3.3.7.1.1Columnpmc1008mpAlmsynthAlmLineIndexread-onlycurrentIndex definition for the pmc1008mpAlmsynthAlmLine table
1.3.6.1.4.1.20044.47.2.3.3.7.1.2Columnpmc1008mpAlmXfpAbsentPortnread-onlycurrentLine Optical Module Absent :This OID indicates that the line optical interface (XFP or OTX) is not plugged in. <Help> This alarm indicates if the line transcei…
1.3.6.1.4.1.20044.47.2.3.3.7.1.3Columnpmc1008mpAlmXfpInitNotComplPortnread-onlycurrentLine Optical Module Ready :This OID indicates that the optical interface (XFP or OTX) is not operational. <Help> This status indicates if the line transceiver …
1.3.6.1.4.1.20044.47.2.3.3.7.1.5Columnpmc1008mpAlmLineHwFailPortnread-onlycurrentLine Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Condtype> LINE_HW_FAIL <Probcause> equipmentMalfunction (1…
1.3.6.1.4.1.20044.47.2.3.3.7.1.6Columnpmc1008mpAlmXfpTxOffPortnread-onlycurrentLine Optical Module Laser Shutdown :This OID indicates the line optical output power is on <Help> This status indicates if the line transceiver laser is ON or …
1.3.6.1.4.1.20044.47.2.3.3.7.1.7Columnpmc1008mpAlmLineLocalOosPortnread-onlycurrentLine Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service…
1.3.6.1.4.1.20044.47.2.3.3.7.1.9Columnpmc1008mpAlmUpRdiInsPortnread-onlycurrentMS-RDI/L-RDI Inserted On Line :This OID indicates an upstream MS-RDI/L-RDI has been inserted in the outgoing 10 Gb/s SDH/SONET signal. <Help> This status indic…
1.3.6.1.4.1.20044.47.2.3.3.7.1.10Columnpmc1008mpAlmLineDdmWarningPortnread-onlycurrentWarning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Warni…
1.3.6.1.4.1.20044.47.2.3.3.7.1.11Columnpmc1008mpAlmLineDdmAlmPortnread-onlycurrentAlarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Alarm ha…
1.3.6.1.4.1.20044.47.2.3.3.7.1.13Columnpmc1008mpAlmLineFailPortnread-onlycurrentLine Port Failure :This OID indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12) <Po…
1.3.6.1.4.1.20044.47.2.3.3.7.1.17Columnpmc1008mpAlmLineActivePortnread-onlycurrentLine Active :This bit indicates the line #n is active on receive side <Help> This status indicates whether the line is active or standby. <Condtype> LINE_ACTIV…
1.3.6.1.4.1.20044.47.2.3.3.128Tablepmc1008mpAlmdfrmAlmTablenot-accessiblecurrentList of pmc1008mpAlmdfrmAlm Article
1.3.6.1.4.1.20044.47.2.3.3.128.1Rowpmc1008mpAlmdfrmAlmEntrynot-accessiblecurrentRow definition for the pmc1008mpAlmdfrmAlm table
1.3.6.1.4.1.20044.47.2.3.3.128.1.1Columnpmc1008mpAlmdfrmAlmIndexread-onlycurrentIndex definition for the pmc1008mpAlmdfrmAlm table
1.3.6.1.4.1.20044.47.2.3.3.128.1.2Columnpmc1008mpAlmDwAisDetPortnread-onlycurrentMS-AIS/L-AIS Detected On Line Input :This OID indicates that an MS-AIS has been detected on incoming OC-48c/STM-16c input signal <Help> This alarm indicates if…
1.3.6.1.4.1.20044.47.2.3.3.128.1.3Columnpmc1008mpAlmDwRdiDetPortnread-onlycurrentMS-RDI/L-RDI Detected On Line Input :This OID indicates that an MS-RDI has been detected on incoming OC-48c/STM-16c input signal <Help> This alarm indicates if…
1.3.6.1.4.1.20044.47.2.3.3.128.1.4Columnpmc1008mpAlmDwOofPortnread-onlycurrentSONET/SDH Line Out Of Frame :This OID indicates that an Out Of Frame has been detected on incoming OC-48c/STM-16c input signal <Help> This alarm indicates if t…
1.3.6.1.4.1.20044.47.2.3.3.128.1.5Columnpmc1008mpAlmDwLofPortnread-onlycurrentSONET/SDH Line Loss Of Frame :This OID indicates that a Loss Of Frame has been detected on incoming OC-48c/STM-16c input signal <Help> This alarm indicates if …
1.3.6.1.4.1.20044.47.2.3.3.133Tablepmc1008mpAlmlineSyncAlarmsTablenot-accessiblecurrentList of pmc1008mpAlmlineSyncAlarms Article
1.3.6.1.4.1.20044.47.2.3.3.133.1Rowpmc1008mpAlmlineSyncAlarmsEntrynot-accessiblecurrentRow definition for the pmc1008mpAlmlineSyncAlarms table
1.3.6.1.4.1.20044.47.2.3.3.133.1.1Columnpmc1008mpAlmlineSyncAlarmsIndexread-onlycurrentIndex definition for the pmc1008mpAlmlineSyncAlarms table
1.3.6.1.4.1.20044.47.2.3.3.133.1.13Columnpmc1008mpAlmDwLockerrPortnread-onlycurrentDownstream Clock Lock Error :This OID indicates that the deserializer input 10 Gb/s clock recovery is not locked. <Condtype> DW_LOCKERR <Probcause> receiveFail…
1.3.6.1.4.1.20044.47.2.3.3.133.1.14Columnpmc1008mpAlmUpLockerrPortnread-onlycurrentUpstream Clock Lock Error :This OID indicates that the serializer output 10 Gb/s clock multiplier unit is not locked. <Condtype> UP_LOCKERR <Probcause> receive…
1.3.6.1.4.1.20044.47.2.3.3.133.1.17Columnpmc1008mpAlmDwLosPortnread-onlycurrentLine Input Loss Of Signal :This OID indicates a loss of signal on the 10 Gb/s input. <Help> This alarm indicates if an optical signal is detected on the line t…
1.3.6.1.4.1.20044.47.2.3.3.211Tablepmc1008mpAlmlineXfp1AlarmsTablenot-accessiblecurrentList of pmc1008mpAlmlineXfp1Alarms Article
1.3.6.1.4.1.20044.47.2.3.3.211.1Rowpmc1008mpAlmlineXfp1AlarmsEntrynot-accessiblecurrentRow definition for the pmc1008mpAlmlineXfp1Alarms table
1.3.6.1.4.1.20044.47.2.3.3.211.1.1Columnpmc1008mpAlmlineXfp1AlarmsIndexread-onlycurrentIndex definition for the pmc1008mpAlmlineXfp1Alarms table
1.3.6.1.4.1.20044.47.2.3.3.211.1.3Columnpmc1008mpAlmModNrPortnread-onlycurrentLine Optical Module Not Ready :This OID indicates that the module is unable to determine correct data. <Help> This alarm indicates if the line transceiver is r…
1.3.6.1.4.1.20044.47.2.3.3.211.1.4Columnpmc1008mpAlmRxCdrNotLockedPortnread-onlycurrentLine Optical Rx CDR Unlocked :This OID indicates that a loss of lock on the receiving side CDR has been detected <Help> This alarm indicates if the Rx CDR is l…
1.3.6.1.4.1.20044.47.2.3.3.211.1.6Columnpmc1008mpAlmRxNrPortnread-onlycurrentLine Optical Rx Not Ready :This OID indicates that a condition has arisen leading to invalid data on the receiving side. <Help> This alarm indicates if the Rx …
1.3.6.1.4.1.20044.47.2.3.3.211.1.7Columnpmc1008mpAlmTxCdrNotLockedPortnread-onlycurrentLine Optical Tx CDR Unlocked :This OID indicates a loss of lock on the transmitting side CDR has been detected. <Help> This alarm indicates if the Tx CDR is lo…
1.3.6.1.4.1.20044.47.2.3.3.211.1.8Columnpmc1008mpAlmTxFaultPortnread-onlycurrentLine Optical Tx Failure :This OID indicates a fault condition on the laser detected by the safety syste <Help> This alarm indicates if the laser of the line tr…
1.3.6.1.4.1.20044.47.2.3.3.211.1.9Columnpmc1008mpAlmTxNrPortnread-onlycurrentLine Optical Tx Not Ready :This OID indicates a condition has arisen leading to invalid data on the transmitting side <Help> This alarm indicates if the Tx par…
1.3.6.1.4.1.20044.47.2.3.3.211.1.11Columnpmc1008mpAlmChannelNotAcquiredPortnread-onlycurrentDWDM Channel Not Acquired :This OID indicates the transceiver didn't tune the DWDM Channel succesfully. <Help> This status indicates the transceiver has not tu…
1.3.6.1.4.1.20044.47.2.3.3.211.1.15Columnpmc1008mpAlmWavelengthUnlockedPortnread-onlycurrentLine Optical Tx Wavelength Unlocked :This OID indicates that the wavelength error is exceeding the manufacturer tolerance <Help> This alarm indicates if the wa…
1.3.6.1.4.1.20044.47.2.3.3.211.1.16Columnpmc1008mpAlmTecFaultPortnread-onlycurrentLine Optical Tx Temp Regul Failed :This OID indicates a failure on the TEC module <Help> This alarm indicates if the TEC of the line transceiver is in fail con…
1.3.6.1.4.1.20044.47.2.3.3.211.1.17Columnpmc1008mpAlmApdSupplyFaultPortnread-onlycurrentLine Rx Photodiode Power Failed :This OID indicates a failure on the APD power supply <Help> This alarm indicates if the APD power supply is in fail condition …
1.3.6.1.4.1.20044.47.3Nodepmc1008mpmeasures
1.3.6.1.4.1.20044.47.3.1Nodepmc1008mpMesrOther
1.3.6.1.4.1.20044.47.3.1.0Scalarpmc1008mpMesrsynth0read-onlydeprecatedNot Used :This OID gives the unit used on AUX1 measurement of XFP#1 (Unit = )
1.3.6.1.4.1.20044.47.3.1.1Scalarpmc1008mpMesrsynth1read-onlydeprecatedNot Used :This OID gives the unit used on AUX2 measurement of XFP#1 (Unit = )
1.3.6.1.4.1.20044.47.3.2Nodepmc1008mpMesrClient
1.3.6.1.4.1.20044.47.3.2.16Tablepmc1008mpMesrtempMeasTablenot-accessiblecurrentList of pmc1008mpMesrtempMeas Article
1.3.6.1.4.1.20044.47.3.2.16.1Rowpmc1008mpMesrtempMeasEntrynot-accessiblecurrentRow definition for the pmc1008mpMesrtempMeas table
1.3.6.1.4.1.20044.47.3.2.16.1.1Columnpmc1008mpMesrtempMeasIndexread-onlycurrentIndex definition for the pmc1008mpMesrtempMeas table
1.3.6.1.4.1.20044.47.3.2.16.1.2Columnpmc1008mpMesrtempMeasPortnread-onlycurrentClient SFP Temperature :This OID gives the temperature value of the SFP plugged in port, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/25…
1.3.6.1.4.1.20044.47.3.2.24Tablepmc1008mpMesrvoltMeasTablenot-accessiblecurrentList of pmc1008mpMesrvoltMeas Article
1.3.6.1.4.1.20044.47.3.2.24.1Rowpmc1008mpMesrvoltMeasEntrynot-accessiblecurrentRow definition for the pmc1008mpMesrvoltMeas table
1.3.6.1.4.1.20044.47.3.2.24.1.1Columnpmc1008mpMesrvoltMeasIndexread-onlycurrentIndex definition for the pmc1008mpMesrvoltMeas table
1.3.6.1.4.1.20044.47.3.2.24.1.2Columnpmc1008mpMesrvoltMeasPortnread-onlycurrentClient SFP Power Supply :This OID gives the 3V3 voltage value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/100…
1.3.6.1.4.1.20044.47.3.2.32Tablepmc1008mpMesrbiasMeasTablenot-accessiblecurrentList of pmc1008mpMesrbiasMeas Article
1.3.6.1.4.1.20044.47.3.2.32.1Rowpmc1008mpMesrbiasMeasEntrynot-accessiblecurrentRow definition for the pmc1008mpMesrbiasMeas table
1.3.6.1.4.1.20044.47.3.2.32.1.1Columnpmc1008mpMesrbiasMeasIndexread-onlycurrentIndex definition for the pmc1008mpMesrbiasMeas table
1.3.6.1.4.1.20044.47.3.2.32.1.2Columnpmc1008mpMesrbiasMeasPortnread-onlycurrentClient SFP Laser Bias :This OID gives the bias value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA…
1.3.6.1.4.1.20044.47.3.2.40Tablepmc1008mpMesrtxpwrMeasTablenot-accessiblecurrentList of pmc1008mpMesrtxpwrMeas Article
1.3.6.1.4.1.20044.47.3.2.40.1Rowpmc1008mpMesrtxpwrMeasEntrynot-accessiblecurrentRow definition for the pmc1008mpMesrtxpwrMeas table
1.3.6.1.4.1.20044.47.3.2.40.1.1Columnpmc1008mpMesrtxpwrMeasIndexread-onlycurrentIndex definition for the pmc1008mpMesrtxpwrMeas table
1.3.6.1.4.1.20044.47.3.2.40.1.2Columnpmc1008mpMesrtxpwrMeasPortnread-onlycurrentClient SFP Tx Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV…
1.3.6.1.4.1.20044.47.3.2.48Tablepmc1008mpMesrrxpwrMeasTablenot-accessiblecurrentList of pmc1008mpMesrrxpwrMeas Article
1.3.6.1.4.1.20044.47.3.2.48.1Rowpmc1008mpMesrrxpwrMeasEntrynot-accessiblecurrentRow definition for the pmc1008mpMesrrxpwrMeas table
1.3.6.1.4.1.20044.47.3.2.48.1.1Columnpmc1008mpMesrrxpwrMeasIndexread-onlycurrentIndex definition for the pmc1008mpMesrrxpwrMeas table
1.3.6.1.4.1.20044.47.3.2.48.1.2Columnpmc1008mpMesrrxpwrMeasPortnread-onlycurrentClient SFP Rx Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-4…
1.3.6.1.4.1.20044.47.3.3Nodepmc1008mpMesrLine
1.3.6.1.4.1.20044.47.3.3.208Tablepmc1008mpMesrxfp1LxModTempMeasTablenot-accessiblecurrentList of pmc1008mpMesrxfp1LxModTempMeas Article
1.3.6.1.4.1.20044.47.3.3.208.1Rowpmc1008mpMesrxfp1LxModTempMeasEntrynot-accessiblecurrentRow definition for the pmc1008mpMesrxfp1LxModTempMeas table
1.3.6.1.4.1.20044.47.3.3.208.1.1Columnpmc1008mpMesrxfp1LxModTempMeasIndexread-onlycurrentIndex definition for the pmc1008mpMesrxfp1LxModTempMeas table
1.3.6.1.4.1.20044.47.3.3.208.1.2Columnpmc1008mpMesrxfp1LxModTempMeasPortnread-onlycurrentLine Optical Module Temperature :This OID gives the temperature of the XFP or OTX plugged in line#n, read from the DDM (Digital Diagnostic Monitoring) (Tempera…
1.3.6.1.4.1.20044.47.3.3.209Tablepmc1008mpMesrxfp1ReservedTablenot-accessibledeprecatedList of pmc1008mpMesrxfp1Reserved Article
1.3.6.1.4.1.20044.47.3.3.209.1Rowpmc1008mpMesrxfp1ReservedEntrynot-accessibledeprecatedRow definition for the pmc1008mpMesrxfp1Reserved table
1.3.6.1.4.1.20044.47.3.3.209.1.1Columnpmc1008mpMesrxfp1ReservedIndexread-onlydeprecatedIndex definition for the pmc1008mpMesrxfp1Reserved table
1.3.6.1.4.1.20044.47.3.3.209.1.2Columnpmc1008mpMesrxfp1ReservedPortnread-onlydeprecatedNot Used :Reserved
1.3.6.1.4.1.20044.47.3.3.210Tablepmc1008mpMesrxfp1LoBiasCurrentMeasTablenot-accessiblecurrentList of pmc1008mpMesrxfp1LoBiasCurrentMeas Article
1.3.6.1.4.1.20044.47.3.3.210.1Rowpmc1008mpMesrxfp1LoBiasCurrentMeasEntrynot-accessiblecurrentRow definition for the pmc1008mpMesrxfp1LoBiasCurrentMeas table
1.3.6.1.4.1.20044.47.3.3.210.1.1Columnpmc1008mpMesrxfp1LoBiasCurrentMeasIndexread-onlycurrentIndex definition for the pmc1008mpMesrxfp1LoBiasCurrentMeas table
1.3.6.1.4.1.20044.47.3.3.210.1.2Columnpmc1008mpMesrxfp1LoBiasCurrentMeasPortnread-onlycurrentLine Optical Module Laser Bias :This OID gives the bias value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Bias = A…
1.3.6.1.4.1.20044.47.3.3.211Tablepmc1008mpMesrxfp1LoTxPowerMeasTablenot-accessiblecurrentList of pmc1008mpMesrxfp1LoTxPowerMeas Article
1.3.6.1.4.1.20044.47.3.3.211.1Rowpmc1008mpMesrxfp1LoTxPowerMeasEntrynot-accessiblecurrentRow definition for the pmc1008mpMesrxfp1LoTxPowerMeas table
1.3.6.1.4.1.20044.47.3.3.211.1.1Columnpmc1008mpMesrxfp1LoTxPowerMeasIndexread-onlycurrentIndex definition for the pmc1008mpMesrxfp1LoTxPowerMeas table
1.3.6.1.4.1.20044.47.3.3.211.1.2Columnpmc1008mpMesrxfp1LoTxPowerMeasPortnread-onlycurrentLine Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (…
1.3.6.1.4.1.20044.47.3.3.212Tablepmc1008mpMesrxfp1LiRxPowerMeasTablenot-accessiblecurrentList of pmc1008mpMesrxfp1LiRxPowerMeas Article
1.3.6.1.4.1.20044.47.3.3.212.1Rowpmc1008mpMesrxfp1LiRxPowerMeasEntrynot-accessiblecurrentRow definition for the pmc1008mpMesrxfp1LiRxPowerMeas table
1.3.6.1.4.1.20044.47.3.3.212.1.1Columnpmc1008mpMesrxfp1LiRxPowerMeasIndexread-onlycurrentIndex definition for the pmc1008mpMesrxfp1LiRxPowerMeas table
1.3.6.1.4.1.20044.47.3.3.212.1.2Columnpmc1008mpMesrxfp1LiRxPowerMeasPortnread-onlycurrentLine Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (P…
1.3.6.1.4.1.20044.47.3.3.213Tablepmc1008mpMesrxfp1LxAux1MeasTablenot-accessibledeprecatedList of pmc1008mpMesrxfp1LxAux1Meas Article
1.3.6.1.4.1.20044.47.3.3.213.1Rowpmc1008mpMesrxfp1LxAux1MeasEntrynot-accessibledeprecatedRow definition for the pmc1008mpMesrxfp1LxAux1Meas table
1.3.6.1.4.1.20044.47.3.3.213.1.1Columnpmc1008mpMesrxfp1LxAux1MeasIndexread-onlydeprecatedIndex definition for the pmc1008mpMesrxfp1LxAux1Meas table
1.3.6.1.4.1.20044.47.3.3.213.1.2Columnpmc1008mpMesrxfp1LxAux1MeasPortnread-onlydeprecatedNot Used :This OID gives the receive power value read in the DDM (Digital Diagnostic Monitoring) of the XFP or OTX plugged in line #n (Unit = ?)
1.3.6.1.4.1.20044.47.3.3.214Tablepmc1008mpMesrxfp1LxAux2MeasTablenot-accessibledeprecatedList of pmc1008mpMesrxfp1LxAux2Meas Article
1.3.6.1.4.1.20044.47.3.3.214.1Rowpmc1008mpMesrxfp1LxAux2MeasEntrynot-accessibledeprecatedRow definition for the pmc1008mpMesrxfp1LxAux2Meas table
1.3.6.1.4.1.20044.47.3.3.214.1.1Columnpmc1008mpMesrxfp1LxAux2MeasIndexread-onlydeprecatedIndex definition for the pmc1008mpMesrxfp1LxAux2Meas table
1.3.6.1.4.1.20044.47.3.3.214.1.2Columnpmc1008mpMesrxfp1LxAux2MeasPortnread-onlydeprecatedNot Used :This OID gives the receive power value read in the DDM (Digital Diagnostic Monitoring) of the XFP or OTX plugged in line #n (Unit = ?)
1.3.6.1.4.1.20044.47.3.3.224Tablepmc1008mpMesrotx1AgingTablenot-accessiblecurrentList of pmc1008mpMesrotx1Aging Article
1.3.6.1.4.1.20044.47.3.3.224.1Rowpmc1008mpMesrotx1AgingEntrynot-accessiblecurrentRow definition for the pmc1008mpMesrotx1Aging table
1.3.6.1.4.1.20044.47.3.3.224.1.1Columnpmc1008mpMesrotx1AgingIndexread-onlycurrentIndex definition for the pmc1008mpMesrotx1Aging table
1.3.6.1.4.1.20044.47.3.3.224.1.2Columnpmc1008mpMesrotx1AgingPortnread-onlycurrentLine OTX TLH Aging :This OID gives the aging of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Aging = AV) (Unit = %) <Help> This measure…
1.3.6.1.4.1.20044.47.3.3.225Tablepmc1008mpMesrotx1LaserTemperatureTablenot-accessibledeprecatedList of pmc1008mpMesrotx1LaserTemperature Article
1.3.6.1.4.1.20044.47.3.3.225.1Rowpmc1008mpMesrotx1LaserTemperatureEntrynot-accessibledeprecatedRow definition for the pmc1008mpMesrotx1LaserTemperature table
1.3.6.1.4.1.20044.47.3.3.225.1.1Columnpmc1008mpMesrotx1LaserTemperatureIndexread-onlydeprecatedIndex definition for the pmc1008mpMesrotx1LaserTemperature table
1.3.6.1.4.1.20044.47.3.3.225.1.2Columnpmc1008mpMesrotx1LaserTemperaturePortnread-onlydeprecatedLine OTX TLH Laser Temperature :This OID gives the laser temperature of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/2…
1.3.6.1.4.1.20044.47.3.3.226Tablepmc1008mpMesrotx1FreqDeviationTablenot-accessiblecurrentList of pmc1008mpMesrotx1FreqDeviation Article
1.3.6.1.4.1.20044.47.3.3.226.1Rowpmc1008mpMesrotx1FreqDeviationEntrynot-accessiblecurrentRow definition for the pmc1008mpMesrotx1FreqDeviation table
1.3.6.1.4.1.20044.47.3.3.226.1.1Columnpmc1008mpMesrotx1FreqDeviationIndexread-onlycurrentIndex definition for the pmc1008mpMesrotx1FreqDeviation table
1.3.6.1.4.1.20044.47.3.3.226.1.2Columnpmc1008mpMesrotx1FreqDeviationPortnread-onlycurrentLine OTX TLH Frequency Deviation :This OID gives the frequency deviation of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Deviation = (A…
1.3.6.1.4.1.20044.47.3.3.227Tablepmc1008mpMesrotx1LaserWvlengthTablenot-accessiblecurrentList of pmc1008mpMesrotx1LaserWvlength Article
1.3.6.1.4.1.20044.47.3.3.227.1Rowpmc1008mpMesrotx1LaserWvlengthEntrynot-accessiblecurrentRow definition for the pmc1008mpMesrotx1LaserWvlength table
1.3.6.1.4.1.20044.47.3.3.227.1.1Columnpmc1008mpMesrotx1LaserWvlengthIndexread-onlycurrentIndex definition for the pmc1008mpMesrotx1LaserWvlength table
1.3.6.1.4.1.20044.47.3.3.227.1.2Columnpmc1008mpMesrotx1LaserWvlengthPortnread-onlycurrentLine Optical Module Wavelength :This OID gives the laser wavelength of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Wavelength=29979245…
1.3.6.1.4.1.20044.47.4Nodepmc1008mpcounters
1.3.6.1.4.1.20044.47.4.1Nodepmc1008mpCntOther
1.3.6.1.4.1.20044.47.4.2Nodepmc1008mpCntClient
1.3.6.1.4.1.20044.47.4.2.16Tablepmc1008mpCntupRaRemCntTablenot-accessiblecurrentList of pmc1008mpCntupRaRemCnt Article
1.3.6.1.4.1.20044.47.4.2.16.1Rowpmc1008mpCntupRaRemCntEntrynot-accessiblecurrentRow definition for the pmc1008mpCntupRaRemCnt table
1.3.6.1.4.1.20044.47.4.2.16.1.1Columnpmc1008mpCntupRaRemCntIndexread-onlycurrentIndex definition for the pmc1008mpCntupRaRemCnt table
1.3.6.1.4.1.20044.47.4.2.16.1.2Columnpmc1008mpCntupRaRemCntValuePortnread-onlycurrentClient Rate Adapt. Words Removal :This counter is incremented each time a rate adaptation 10B word is removed from the Client input stream
1.3.6.1.4.1.20044.47.4.2.16.1.3Columnpmc1008mpCntupRaRemCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the rate adaptation removal counter value is invalid on Port
1.3.6.1.4.1.20044.47.4.2.16.1.4Columnpmc1008mpCntupRaRemCntOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a rate adaptation removal counter overload on Port
1.3.6.1.4.1.20044.47.4.2.24Tablepmc1008mpCntupRaInsCntTablenot-accessiblecurrentList of pmc1008mpCntupRaInsCnt Article
1.3.6.1.4.1.20044.47.4.2.24.1Rowpmc1008mpCntupRaInsCntEntrynot-accessiblecurrentRow definition for the pmc1008mpCntupRaInsCnt table
1.3.6.1.4.1.20044.47.4.2.24.1.1Columnpmc1008mpCntupRaInsCntIndexread-onlycurrentIndex definition for the pmc1008mpCntupRaInsCnt table
1.3.6.1.4.1.20044.47.4.2.24.1.2Columnpmc1008mpCntupRaInsCntValuePortnread-onlycurrentClient Rate Adapt. Words Insertion :This counter is incremented each time a rate adaptation 10B word is inserted in the Client input stream
1.3.6.1.4.1.20044.47.4.2.24.1.3Columnpmc1008mpCntupRaInsCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the rate adaptation insertion counter value is invalid on Port
1.3.6.1.4.1.20044.47.4.2.24.1.4Columnpmc1008mpCntupRaInsCntOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a rate adaptation insertion counter overload on Port
1.3.6.1.4.1.20044.47.4.2.32Tablepmc1008mpCntupRdErrCntTablenot-accessiblecurrentList of pmc1008mpCntupRdErrCnt Article
1.3.6.1.4.1.20044.47.4.2.32.1Rowpmc1008mpCntupRdErrCntEntrynot-accessiblecurrentRow definition for the pmc1008mpCntupRdErrCnt table
1.3.6.1.4.1.20044.47.4.2.32.1.1Columnpmc1008mpCntupRdErrCntIndexread-onlycurrentIndex definition for the pmc1008mpCntupRdErrCnt table
1.3.6.1.4.1.20044.47.4.2.32.1.2Columnpmc1008mpCntupRdErrCntValuePortnread-onlycurrentClient Input Errors :This counter is increased each time a 10b/8b running disparity error is detected on the Client input stream <Help> This counter gives the …
1.3.6.1.4.1.20044.47.4.2.32.1.3Columnpmc1008mpCntupRdErrCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the client error counter value is invalid on Port
1.3.6.1.4.1.20044.47.4.2.32.1.4Columnpmc1008mpCntupRdErrCntOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a client input error counter overload on Port
1.3.6.1.4.1.20044.47.4.2.40Tablepmc1008mpCntupTimCntTablenot-accessiblecurrentList of pmc1008mpCntupTimCnt Article
1.3.6.1.4.1.20044.47.4.2.40.1Rowpmc1008mpCntupTimCntEntrynot-accessiblecurrentRow definition for the pmc1008mpCntupTimCnt table
1.3.6.1.4.1.20044.47.4.2.40.1.1Columnpmc1008mpCntupTimCntIndexread-onlycurrentIndex definition for the pmc1008mpCntupTimCnt table
1.3.6.1.4.1.20044.47.4.2.40.1.2Columnpmc1008mpCntupTimCntValuePortnread-onlycurrentClient Upstream Timer Counter :This is the timing counter dedicated to the upstream access counters. It is incremented every 125 us.
1.3.6.1.4.1.20044.47.4.2.40.1.3Columnpmc1008mpCntupTimCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the upstream timing counter value is invalid on Port
1.3.6.1.4.1.20044.47.4.2.40.1.4Columnpmc1008mpCntupTimCntOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a upstream timing counter overload on Port
1.3.6.1.4.1.20044.47.4.2.48Tablepmc1008mpCntupCvErrCntTablenot-accessiblecurrentList of pmc1008mpCntupCvErrCnt Article
1.3.6.1.4.1.20044.47.4.2.48.1Rowpmc1008mpCntupCvErrCntEntrynot-accessiblecurrentRow definition for the pmc1008mpCntupCvErrCnt table
1.3.6.1.4.1.20044.47.4.2.48.1.1Columnpmc1008mpCntupCvErrCntIndexread-onlycurrentIndex definition for the pmc1008mpCntupCvErrCnt table
1.3.6.1.4.1.20044.47.4.2.48.1.2Columnpmc1008mpCntupCvErrCntValuePortnread-onlycurrentClient Coding Violation Counter :This counter is increased each time a 10b/8b coding violation is detected on the Client input stream
1.3.6.1.4.1.20044.47.4.2.48.1.3Columnpmc1008mpCntupCvErrCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the coding violation counter value is invalid on Port
1.3.6.1.4.1.20044.47.4.2.48.1.4Columnpmc1008mpCntupCvErrCntOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a coding violation counter overload on Port
1.3.6.1.4.1.20044.47.4.2.64Tablepmc1008mpCntdwCbipCntTablenot-accessiblecurrentList of pmc1008mpCntdwCbipCnt Article
1.3.6.1.4.1.20044.47.4.2.64.1Rowpmc1008mpCntdwCbipCntEntrynot-accessiblecurrentRow definition for the pmc1008mpCntdwCbipCnt table
1.3.6.1.4.1.20044.47.4.2.64.1.1Columnpmc1008mpCntdwCbipCntIndexread-onlycurrentIndex definition for the pmc1008mpCntdwCbipCnt table
1.3.6.1.4.1.20044.47.4.2.64.1.2Columnpmc1008mpCntdwCbipCntValuePortnread-onlycurrentClient Output Errors :This counter is incremented each time a CBIP parity error is detected on the Client output stream <Help> This counter gives the number of…
1.3.6.1.4.1.20044.47.4.2.64.1.3Columnpmc1008mpCntdwCbipCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the CBIP error counter value is invalid on Port
1.3.6.1.4.1.20044.47.4.2.64.1.4Columnpmc1008mpCntdwCbipCntOverloadPortnread-onlycurrentClient CBIP Counter Overload :This OID when set indicates a CBIP error counter overload on Port
1.3.6.1.4.1.20044.47.4.2.72Tablepmc1008mpCntdwTimCntTablenot-accessiblecurrentList of pmc1008mpCntdwTimCnt Article
1.3.6.1.4.1.20044.47.4.2.72.1Rowpmc1008mpCntdwTimCntEntrynot-accessiblecurrentRow definition for the pmc1008mpCntdwTimCnt table
1.3.6.1.4.1.20044.47.4.2.72.1.1Columnpmc1008mpCntdwTimCntIndexread-onlycurrentIndex definition for the pmc1008mpCntdwTimCnt table
1.3.6.1.4.1.20044.47.4.2.72.1.2Columnpmc1008mpCntdwTimCntValuePortnread-onlycurrentClient Downstream Timer Counter :This is the timing counter dedicated to the downstream access counters. It is incremented every 125 us.
1.3.6.1.4.1.20044.47.4.2.72.1.3Columnpmc1008mpCntdwTimCntErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the downstream timer counter value is invalid on Port
1.3.6.1.4.1.20044.47.4.2.72.1.4Columnpmc1008mpCntdwTimCntOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a downstream timer counter overload on Port
1.3.6.1.4.1.20044.47.4.3Nodepmc1008mpCntLine
1.3.6.1.4.1.20044.47.4.3.152Tablepmc1008mpCntdfrmB1ErrCntTablenot-accessiblecurrentList of pmc1008mpCntdfrmB1ErrCnt Article
1.3.6.1.4.1.20044.47.4.3.152.1Rowpmc1008mpCntdfrmB1ErrCntEntrynot-accessiblecurrentRow definition for the pmc1008mpCntdfrmB1ErrCnt table
1.3.6.1.4.1.20044.47.4.3.152.1.1Columnpmc1008mpCntdfrmB1ErrCntIndexread-onlycurrentIndex definition for the pmc1008mpCntdfrmB1ErrCnt table
1.3.6.1.4.1.20044.47.4.3.152.1.2Columnpmc1008mpCntdfrmB1ErrCntValuePortnread-onlycurrentLine Input B1 Errors :This counter is incremented each time a B1 error is detected on the Deframer input stream. <Help> This counter gives the number of B1 err…
1.3.6.1.4.1.20044.47.4.3.152.1.3Columnpmc1008mpCntdfrmB1ErrCntErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the B1 error counter value is invalid on Port
1.3.6.1.4.1.20044.47.4.3.152.1.4Columnpmc1008mpCntdfrmB1ErrCntOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a B1 error counter overload on Port
1.3.6.1.4.1.20044.47.4.3.153Tablepmc1008mpCntdfrmTimCntTablenot-accessiblecurrentList of pmc1008mpCntdfrmTimCnt Article
1.3.6.1.4.1.20044.47.4.3.153.1Rowpmc1008mpCntdfrmTimCntEntrynot-accessiblecurrentRow definition for the pmc1008mpCntdfrmTimCnt table
1.3.6.1.4.1.20044.47.4.3.153.1.1Columnpmc1008mpCntdfrmTimCntIndexread-onlycurrentIndex definition for the pmc1008mpCntdfrmTimCnt table
1.3.6.1.4.1.20044.47.4.3.153.1.2Columnpmc1008mpCntdfrmTimCntValuePortnread-onlycurrentLine Timer Counter :This is the timing counter dedicated to the downstream deframer counters. It is incremented every 125 us.
1.3.6.1.4.1.20044.47.4.3.153.1.3Columnpmc1008mpCntdfrmTimCntErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.47.4.3.153.1.4Columnpmc1008mpCntdfrmTimCntOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.47.4.3.154Tablepmc1008mpCntdfrmPrimLineErrCntTablenot-accessiblecurrentList of pmc1008mpCntdfrmPrimLineErrCnt Article
1.3.6.1.4.1.20044.47.4.3.154.1Rowpmc1008mpCntdfrmPrimLineErrCntEntrynot-accessiblecurrentRow definition for the pmc1008mpCntdfrmPrimLineErrCnt table
1.3.6.1.4.1.20044.47.4.3.154.1.1Columnpmc1008mpCntdfrmPrimLineErrCntIndexread-onlycurrentIndex definition for the pmc1008mpCntdfrmPrimLineErrCnt table
1.3.6.1.4.1.20044.47.4.3.154.1.2Columnpmc1008mpCntdfrmPrimLineErrCntValuePortnread-onlycurrentLine Input FEC Corrected Errors :This counter is incremented each time the FEC is correcting an error on the line input stream. <Help> This counter gives the n…
1.3.6.1.4.1.20044.47.4.3.154.1.3Columnpmc1008mpCntdfrmPrimLineErrCntErrorPortnread-onlycurrentFEC Counter Error :This bit when set indicates the FEC corrected errors counter value is invalid on Line
1.3.6.1.4.1.20044.47.4.3.154.1.4Columnpmc1008mpCntdfrmPrimLineErrCntOverloadPortnread-onlycurrentFEC Counter Overload :This bit when set indicates a FEC corrected errors counter overload on Line
1.3.6.1.4.1.20044.47.4.259Scalarpmc1008mpCntCountersResetread-writecurrentCounters Reset:This OID resets and restarts all the counters
1.3.6.1.4.1.20044.47.4.260Scalarpmc1008mpCntCountersStopread-writecurrentCounters stop:This OID stops all the counters
1.3.6.1.4.1.20044.47.6Nodepmc1008mpcontrolsWrite
1.3.6.1.4.1.20044.47.6.1Nodepmc1008mpCtrlOther
1.3.6.1.4.1.20044.47.6.1.1Nodepmc1008mpCtrlconfMgnt1
1.3.6.1.4.1.20044.47.6.1.1.1Scalarpmc1008mpCtrlConf1Load1read-writecurrentLoad Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM.
1.3.6.1.4.1.20044.47.6.1.1.2Scalarpmc1008mpCtrlConf2Load1read-writecurrentLoad Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM.
1.3.6.1.4.1.20044.47.6.1.1.10Scalarpmc1008mpCtrlConf2Flash1read-writecurrentWrite Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura…
1.3.6.1.4.1.20044.47.6.1.1.14Scalarpmc1008mpCtrlConf2Clear1read-writecurrentClear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o…
1.3.6.1.4.1.20044.47.6.1.4Nodepmc1008mpCtrlsynth4
1.3.6.1.4.1.20044.47.6.1.4.1Scalarpmc1008mpCtrlCorrelatOnread-writecurrentEnable Alarm Correlation :This OID enables the alarm correlation in the PM.
1.3.6.1.4.1.20044.47.6.1.4.2Scalarpmc1008mpCtrlCorrelatOffread-writecurrentDisable Alarm Correlation :This OID disables the alarm correlation in the PM.
1.3.6.1.4.1.20044.47.6.1.5Nodepmc1008mpCtrlswMgnt
1.3.6.1.4.1.20044.47.6.1.5.2Scalarpmc1008mpCtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> …
1.3.6.1.4.1.20044.47.6.1.5.3Scalarpmc1008mpCtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th…
1.3.6.1.4.1.20044.47.6.1.5.5Scalarpmc1008mpCtrlLoadSwBank1read-writecurrentSet Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW…
1.3.6.1.4.1.20044.47.6.1.5.6Scalarpmc1008mpCtrlLoadSwBank2read-writecurrentSet Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S…
1.3.6.1.4.1.20044.47.6.1.6Nodepmc1008mpCtrlgwMgnt
1.3.6.1.4.1.20044.47.6.1.6.1Scalarpmc1008mpCtrlCurrentGwResetread-writecurrentActive Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting.
1.3.6.1.4.1.20044.47.6.1.6.5Scalarpmc1008mpCtrlLoadGwBank1read-writecurrentSet Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.47.6.1.6.6Scalarpmc1008mpCtrlLoadGwBank2read-writecurrentSet Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.47.6.1.6.7Scalarpmc1008mpCtrlLoadGwBank3read-writecurrentSet Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.47.6.1.6.8Scalarpmc1008mpCtrlLoadGwBank4read-writecurrentSet Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.47.6.1.192Nodepmc1008mpCtrlledTest
1.3.6.1.4.1.20044.47.6.1.192.1Scalarpmc1008mpCtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.47.6.1.192.2Scalarpmc1008mpCtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.47.6.1.192.3Scalarpmc1008mpCtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.47.6.1.193Nodepmc1008mpCtrlmoduleOosMode
1.3.6.1.4.1.20044.47.6.1.193.1Scalarpmc1008mpCtrlModuleOosModeread-writecurrentPM Out Of Service :This OID sets the PM Out Of Service <Help> This control defines the service state of the complete module
1.3.6.1.4.1.20044.47.6.1.196Scalarpmc1008mpCtrlmoduleDccMgntread-writecurrentDCC Mode :This OID defines the DCC mode of the PM (No DCC, Master, Slave Line 1&2, Terminal Line 1, Terminal Line 2, Terminal Line 1&2) <Help> This control def…
1.3.6.1.4.1.20044.47.6.1.197Nodepmc1008mpCtrlmaintenanceMode
1.3.6.1.4.1.20044.47.6.1.197.1Scalarpmc1008mpCtrlMaintenanceModeread-writecurrentEnable Maintenance :This OID enables the maintenance mode on the PM. <Help> This control enables the maintenance mode on the PM.
1.3.6.1.4.1.20044.47.6.2Nodepmc1008mpCtrlClient
1.3.6.1.4.1.20044.47.6.2.16Tablepmc1008mpCtrlaccessLoopTablenot-accessiblecurrentList of pmc1008mpCtrlaccessLoop Article
1.3.6.1.4.1.20044.47.6.2.16.1Rowpmc1008mpCtrlaccessLoopEntrynot-accessiblecurrentRow definition for the pmc1008mpCtrlaccessLoop table
1.3.6.1.4.1.20044.47.6.2.16.1.1Columnpmc1008mpCtrlaccessLoopIndexread-onlycurrentIndex definition for the pmc1008mpCtrlaccessLoop table
1.3.6.1.4.1.20044.47.6.2.16.1.2Columnpmc1008mpCtrlaccessLoopPortnread-writecurrentClient Facility Loopback :This OID operates a Client Facility Loopback, looping client input signal on the client output port. The loop is located on the clien…
1.3.6.1.4.1.20044.47.6.2.18Tablepmc1008mpCtrlportOosModeTablenot-accessiblecurrentList of pmc1008mpCtrlportOosMode Article
1.3.6.1.4.1.20044.47.6.2.18.1Rowpmc1008mpCtrlportOosModeEntrynot-accessiblecurrentRow definition for the pmc1008mpCtrlportOosMode table
1.3.6.1.4.1.20044.47.6.2.18.1.1Columnpmc1008mpCtrlportOosModeIndexread-onlycurrentIndex definition for the pmc1008mpCtrlportOosMode table
1.3.6.1.4.1.20044.47.6.2.18.1.2Columnpmc1008mpCtrlportOosModePortnread-writecurrentClient Port Out Of Service :This OID sets the client port Out Of Service <Help> This controls defines the service state of the client port
1.3.6.1.4.1.20044.47.6.2.19Tablepmc1008mpCtrlsfpOnCtrlTablenot-accessiblecurrentList of pmc1008mpCtrlsfpOnCtrl Article
1.3.6.1.4.1.20044.47.6.2.19.1Rowpmc1008mpCtrlsfpOnCtrlEntrynot-accessiblecurrentRow definition for the pmc1008mpCtrlsfpOnCtrl table
1.3.6.1.4.1.20044.47.6.2.19.1.1Columnpmc1008mpCtrlsfpOnCtrlIndexread-onlycurrentIndex definition for the pmc1008mpCtrlsfpOnCtrl table
1.3.6.1.4.1.20044.47.6.2.19.1.2Columnpmc1008mpCtrlsfpOnCtrlPortnread-writecurrentClient SFP Optical Laser ON :This OID switches on the SFP.
1.3.6.1.4.1.20044.47.6.2.20Tablepmc1008mpCtrlsfpOffCtrlTablenot-accessiblecurrentList of pmc1008mpCtrlsfpOffCtrl Article
1.3.6.1.4.1.20044.47.6.2.20.1Rowpmc1008mpCtrlsfpOffCtrlEntrynot-accessiblecurrentRow definition for the pmc1008mpCtrlsfpOffCtrl table
1.3.6.1.4.1.20044.47.6.2.20.1.1Columnpmc1008mpCtrlsfpOffCtrlIndexread-onlycurrentIndex definition for the pmc1008mpCtrlsfpOffCtrl table
1.3.6.1.4.1.20044.47.6.2.20.1.2Columnpmc1008mpCtrlsfpOffCtrlPortnread-writecurrentClient SFP Optical Laser OFF :This OID switches off the SFP. <Help> This control defines the laser state of the client transceiver
1.3.6.1.4.1.20044.47.6.2.21Tablepmc1008mpCtrlcsfUpInsTablenot-accessiblecurrentList of pmc1008mpCtrlcsfUpIns Article
1.3.6.1.4.1.20044.47.6.2.21.1Rowpmc1008mpCtrlcsfUpInsEntrynot-accessiblecurrentRow definition for the pmc1008mpCtrlcsfUpIns table
1.3.6.1.4.1.20044.47.6.2.21.1.1Columnpmc1008mpCtrlcsfUpInsIndexread-onlycurrentIndex definition for the pmc1008mpCtrlcsfUpIns table
1.3.6.1.4.1.20044.47.6.2.21.1.2Columnpmc1008mpCtrlcsfUpInsPortnread-writecurrentClient Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo…
1.3.6.1.4.1.20044.47.6.2.22Tablepmc1008mpCtrlcaisDwInsTablenot-accessiblecurrentList of pmc1008mpCtrlcaisDwIns Article
1.3.6.1.4.1.20044.47.6.2.22.1Rowpmc1008mpCtrlcaisDwInsEntrynot-accessiblecurrentRow definition for the pmc1008mpCtrlcaisDwIns table
1.3.6.1.4.1.20044.47.6.2.22.1.1Columnpmc1008mpCtrlcaisDwInsIndexread-onlycurrentIndex definition for the pmc1008mpCtrlcaisDwIns table
1.3.6.1.4.1.20044.47.6.2.22.1.2Columnpmc1008mpCtrlcaisDwInsPortnread-writecurrentClient AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port
1.3.6.1.4.1.20044.47.6.2.26Tablepmc1008mpCtrlclientAccessTermLoopTablenot-accessiblecurrentList of pmc1008mpCtrlclientAccessTermLoop Article
1.3.6.1.4.1.20044.47.6.2.26.1Rowpmc1008mpCtrlclientAccessTermLoopEntrynot-accessiblecurrentRow definition for the pmc1008mpCtrlclientAccessTermLoop table
1.3.6.1.4.1.20044.47.6.2.26.1.1Columnpmc1008mpCtrlclientAccessTermLoopIndexread-onlycurrentIndex definition for the pmc1008mpCtrlclientAccessTermLoop table
1.3.6.1.4.1.20044.47.6.2.26.1.2Columnpmc1008mpCtrlclientAccessTermLoopPortnread-writecurrentClient Terminal Loopback :This OID operates a Client Terminal Loopback, looping client input signal on the client output port. The loop is located on the line …
1.3.6.1.4.1.20044.47.6.2.48Tablepmc1008mpCtrlprotocolTablenot-accessiblecurrentList of pmc1008mpCtrlprotocol Article
1.3.6.1.4.1.20044.47.6.2.48.1Rowpmc1008mpCtrlprotocolEntrynot-accessiblecurrentRow definition for the pmc1008mpCtrlprotocol table
1.3.6.1.4.1.20044.47.6.2.48.1.1Columnpmc1008mpCtrlprotocolIndexread-onlycurrentIndex definition for the pmc1008mpCtrlprotocol table
1.3.6.1.4.1.20044.47.6.2.48.1.2Columnpmc1008mpCtrlprotocolPortnread-writecurrentProtocol used for client port: This OID sets the protocol of the Client port.
1.3.6.1.4.1.20044.47.6.2.128Tablepmc1008mpCtrladddropTsClientARxProtectTablenot-accessiblecurrentList of pmc1008mpCtrladddropTsClientARxProtect Article
1.3.6.1.4.1.20044.47.6.2.128.1Rowpmc1008mpCtrladddropTsClientARxProtectEntrynot-accessiblecurrentRow definition for the pmc1008mpCtrladddropTsClientARxProtect table
1.3.6.1.4.1.20044.47.6.2.128.1.1Columnpmc1008mpCtrladddropTsClientARxProtectIndexread-onlycurrentIndex definition for the pmc1008mpCtrladddropTsClientARxProtect table
1.3.6.1.4.1.20044.47.6.2.128.1.2Columnpmc1008mpCtrladddropTsClientARxProtectPortnread-writecurrentClient A Switch Mode :This bit selects the manual (1) or automatic (0) switch method <Help> This control defines the protection switch mode on the client inter…
1.3.6.1.4.1.20044.47.6.2.136Tablepmc1008mpCtrladddropTsPairModeTablenot-accessiblecurrentList of pmc1008mpCtrladddropTsPairMode Article
1.3.6.1.4.1.20044.47.6.2.136.1Rowpmc1008mpCtrladddropTsPairModeEntrynot-accessiblecurrentRow definition for the pmc1008mpCtrladddropTsPairMode table
1.3.6.1.4.1.20044.47.6.2.136.1.1Columnpmc1008mpCtrladddropTsPairModeIndexread-onlycurrentIndex definition for the pmc1008mpCtrladddropTsPairMode table
1.3.6.1.4.1.20044.47.6.2.136.1.2Columnpmc1008mpCtrladddropTsPairModePortnread-writecurrentTS Group Mode :This OID selects the mode on the group of clients <Help> This control defines the mode (Add/Drop or Split&Select) of two consecutive Client (1/2…
1.3.6.1.4.1.20044.47.6.2.271Tablepmc1008mpCtrlclientResetAllCountTablenot-accessiblecurrentList of pmc1008mpCtrlclientResetAllCount Article
1.3.6.1.4.1.20044.47.6.2.271.1Rowpmc1008mpCtrlclientResetAllCountEntrynot-accessiblecurrentRow definition for the pmc1008mpCtrlclientResetAllCount table
1.3.6.1.4.1.20044.47.6.2.271.1.1Columnpmc1008mpCtrlclientResetAllCountIndexread-onlycurrentIndex definition for the pmc1008mpCtrlclientResetAllCount table
1.3.6.1.4.1.20044.47.6.2.271.1.2Columnpmc1008mpCtrlclientResetAllCountsPortnread-writecurrentClient Counters Reset :This OID resets every counter on the client port <Help> This control operates a reset on the statistics current ,previous and history cl…
1.3.6.1.4.1.20044.47.6.3Nodepmc1008mpCtrlLine
1.3.6.1.4.1.20044.47.6.3.64Nodepmc1008mpCtrlcommAccessLoop
1.3.6.1.4.1.20044.47.6.3.64.1Scalarpmc1008mpCtrlCommAccessloopread-writedeprecatedPM Full Access Loop Mode :This OID, when set, puts the module in common access loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.
1.3.6.1.4.1.20044.47.6.3.66Nodepmc1008mpCtrllineLoop
1.3.6.1.4.1.20044.47.6.3.66.1Scalarpmc1008mpCtrlLineLoopread-writedeprecatedPM Line Loop Mode :This OID, when set at '1' puts the module in line loopback mode, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. The Ups…
1.3.6.1.4.1.20044.47.6.3.67Nodepmc1008mpCtrlmsAis
1.3.6.1.4.1.20044.47.6.3.67.1Scalarpmc1008mpCtrlMsAisread-writecurrentInsert MS-AIS/L-AIS On Line Output :This OID, when set, inserts an MS-AIS/L-AIS in the outgoing STM-64/OC-192 signal.
1.3.6.1.4.1.20044.47.6.3.69Tablepmc1008mpCtrlfecDisableTablenot-accessiblecurrentList of pmc1008mpCtrlfecDisable Article
1.3.6.1.4.1.20044.47.6.3.69.1Rowpmc1008mpCtrlfecDisableEntrynot-accessiblecurrentRow definition for the pmc1008mpCtrlfecDisable table
1.3.6.1.4.1.20044.47.6.3.69.1.1Columnpmc1008mpCtrlfecDisableIndexread-onlycurrentIndex definition for the pmc1008mpCtrlfecDisable table
1.3.6.1.4.1.20044.47.6.3.69.1.2Columnpmc1008mpCtrlfecDisablePortnread-writecurrentForward Error Correction Inhibition :This OID, when set, inhibits the Forward Error Correction feature on the line input <Help> This control enables/disables t…
1.3.6.1.4.1.20044.47.6.3.74Tablepmc1008mpCtrllineOosModeTablenot-accessiblecurrentList of pmc1008mpCtrllineOosMode Article
1.3.6.1.4.1.20044.47.6.3.74.1Rowpmc1008mpCtrllineOosModeEntrynot-accessiblecurrentRow definition for the pmc1008mpCtrllineOosMode table
1.3.6.1.4.1.20044.47.6.3.74.1.1Columnpmc1008mpCtrllineOosModeIndexread-onlycurrentIndex definition for the pmc1008mpCtrllineOosMode table
1.3.6.1.4.1.20044.47.6.3.74.1.2Columnpmc1008mpCtrllineOosModePortnread-writecurrentLine Port Out Of Service :This OID sets the line port Out Of Service <Help> This control defines the service state of the line port
1.3.6.1.4.1.20044.47.6.3.208Tablepmc1008mpCtrlxfpOnoffTablenot-accessiblecurrentList of pmc1008mpCtrlxfpOnoff Article
1.3.6.1.4.1.20044.47.6.3.208.1Rowpmc1008mpCtrlxfpOnoffEntrynot-accessiblecurrentRow definition for the pmc1008mpCtrlxfpOnoff table
1.3.6.1.4.1.20044.47.6.3.208.1.1Columnpmc1008mpCtrlxfpOnoffIndexread-onlycurrentIndex definition for the pmc1008mpCtrlxfpOnoff table
1.3.6.1.4.1.20044.47.6.3.208.1.2Columnpmc1008mpCtrlxfpOnoffPortnread-writecurrentXFP/OTX Optical Laser OFF :This OID switches off the XFP or the OTX <Help> This control defines the laser state of the line transceiver
1.3.6.1.4.1.20044.47.6.3.209Tablepmc1008mpCtrlxfpLineLoopTablenot-accessiblecurrentList of pmc1008mpCtrlxfpLineLoop Article
1.3.6.1.4.1.20044.47.6.3.209.1Rowpmc1008mpCtrlxfpLineLoopEntrynot-accessiblecurrentRow definition for the pmc1008mpCtrlxfpLineLoop table
1.3.6.1.4.1.20044.47.6.3.209.1.1Columnpmc1008mpCtrlxfpLineLoopIndexread-onlycurrentIndex definition for the pmc1008mpCtrlxfpLineLoop table
1.3.6.1.4.1.20044.47.6.3.209.1.2Columnpmc1008mpCtrlxfpLineLoopPortnread-writecurrentLine XFP/OTX Loop :This OID operates a line loopback on the XFP or the OTX <Help> This control defines the line loop back of the line transceiver
1.3.6.1.4.1.20044.47.6.3.210Tablepmc1008mpCtrlxfpXfiLoopTablenot-accessiblecurrentList of pmc1008mpCtrlxfpXfiLoop Article
1.3.6.1.4.1.20044.47.6.3.210.1Rowpmc1008mpCtrlxfpXfiLoopEntrynot-accessiblecurrentRow definition for the pmc1008mpCtrlxfpXfiLoop table
1.3.6.1.4.1.20044.47.6.3.210.1.1Columnpmc1008mpCtrlxfpXfiLoopIndexread-onlycurrentIndex definition for the pmc1008mpCtrlxfpXfiLoop table
1.3.6.1.4.1.20044.47.6.3.210.1.2Columnpmc1008mpCtrlxfpXfiLoopPortnread-writecurrentLine XFP/OTX XFI Loop :This OID operates a XFI loopback on the XFP or the OTX <Help> This control defines the XFI loop back of the line transceiver
1.3.6.1.4.1.20044.47.6.3.212Tablepmc1008mpCtrllineTunableChannelTablenot-accessiblecurrentList of pmc1008mpCtrllineTunableChannel Article
1.3.6.1.4.1.20044.47.6.3.212.1Rowpmc1008mpCtrllineTunableChannelEntrynot-accessiblecurrentRow definition for the pmc1008mpCtrllineTunableChannel table
1.3.6.1.4.1.20044.47.6.3.212.1.1Columnpmc1008mpCtrllineTunableChannelIndexread-onlycurrentIndex definition for the pmc1008mpCtrllineTunableChannel table
1.3.6.1.4.1.20044.47.6.3.212.1.2Columnpmc1008mpCtrllineTunableChannelPortnread-writecurrentITU Channel :This OID selects the ITU channel of the Line OTX TLH Laser <Help> This control defines the ITU channel of the Line OTX TLH Laser
1.3.6.1.4.1.20044.47.6.3.213Tablepmc1008mpCtrllinePhotodiodeModeTablenot-accessiblecurrentList of pmc1008mpCtrllinePhotodiodeMode Article
1.3.6.1.4.1.20044.47.6.3.213.1Rowpmc1008mpCtrllinePhotodiodeModeEntrynot-accessiblecurrentRow definition for the pmc1008mpCtrllinePhotodiodeMode table
1.3.6.1.4.1.20044.47.6.3.213.1.1Columnpmc1008mpCtrllinePhotodiodeModeIndexread-onlycurrentIndex definition for the pmc1008mpCtrllinePhotodiodeMode table
1.3.6.1.4.1.20044.47.6.3.213.1.2Columnpmc1008mpCtrllinePhotodiodeModePortnread-writecurrentOTX TLH Rx Sens. Mode :This OID defines the Rx sensiblity mode of the Line OTX TLH <Help> This control defines the receiver sensibility mode of the Line OTX TL…
1.3.6.1.4.1.20044.47.6.3.214Tablepmc1008mpCtrllinePhotodiodeValueTablenot-accessiblecurrentList of pmc1008mpCtrllinePhotodiodeValue Article
1.3.6.1.4.1.20044.47.6.3.214.1Rowpmc1008mpCtrllinePhotodiodeValueEntrynot-accessiblecurrentRow definition for the pmc1008mpCtrllinePhotodiodeValue table
1.3.6.1.4.1.20044.47.6.3.214.1.1Columnpmc1008mpCtrllinePhotodiodeValueIndexread-onlycurrentIndex definition for the pmc1008mpCtrllinePhotodiodeValue table
1.3.6.1.4.1.20044.47.6.3.214.1.2Columnpmc1008mpCtrllinePhotodiodeValuePortnread-writecurrentOTX TLH Rx Sensibility :This OID sets the Rx sensibility of the Line OTX TLH (custom mode only) <Help> This control defines the receiver sensibility value (onl…
1.3.6.1.4.1.20044.47.6.3.215Tablepmc1008mpCtrllinePowerLaserTablenot-accessiblecurrentList of pmc1008mpCtrllinePowerLaser Article
1.3.6.1.4.1.20044.47.6.3.215.1Rowpmc1008mpCtrllinePowerLaserEntrynot-accessiblecurrentRow definition for the pmc1008mpCtrllinePowerLaser table
1.3.6.1.4.1.20044.47.6.3.215.1.1Columnpmc1008mpCtrllinePowerLaserIndexread-onlycurrentIndex definition for the pmc1008mpCtrllinePowerLaser table
1.3.6.1.4.1.20044.47.6.3.215.1.2Columnpmc1008mpCtrllinePowerLaserPortnread-writecurrentLaser Output Power [3-5] :This OID sets the output power value on the laser of the Line OTX TLH (Unit = dBm) <Help> This control defines the start-up output po…
1.3.6.1.4.1.20044.47.6.3.216Tablepmc1008mpCtrlotxVlhResetTablenot-accessiblecurrentList of pmc1008mpCtrlotxVlhReset Article
1.3.6.1.4.1.20044.47.6.3.216.1Rowpmc1008mpCtrlotxVlhResetEntrynot-accessiblecurrentRow definition for the pmc1008mpCtrlotxVlhReset table
1.3.6.1.4.1.20044.47.6.3.216.1.1Columnpmc1008mpCtrlotxVlhResetIndexread-onlycurrentIndex definition for the pmc1008mpCtrlotxVlhReset table
1.3.6.1.4.1.20044.47.6.3.216.1.2Columnpmc1008mpCtrlOtxVlhResetPortnread-writecurrentOTX-VLH Reset :This OID resets the OTX-VLH module <Help> This control resets the OTX-VLH and its parameters
1.3.6.1.4.1.20044.47.6.3.217Tablepmc1008mpCtrllineAccessLoopTablenot-accessiblecurrentList of pmc1008mpCtrllineAccessLoop Article
1.3.6.1.4.1.20044.47.6.3.217.1Rowpmc1008mpCtrllineAccessLoopEntrynot-accessiblecurrentRow definition for the pmc1008mpCtrllineAccessLoop table
1.3.6.1.4.1.20044.47.6.3.217.1.1Columnpmc1008mpCtrllineAccessLoopIndexread-onlycurrentIndex definition for the pmc1008mpCtrllineAccessLoop table
1.3.6.1.4.1.20044.47.6.3.217.1.2Columnpmc1008mpCtrllineAccessLoopPortnread-writecurrentLine Facility Loopback :This OID operates a Line Facility Loopback, looping line input signal on the line output port. The loop is located on the line transcei…
1.3.6.1.4.1.20044.47.6.3.218Tablepmc1008mpCtrllineLoopTransceiverTablenot-accessiblecurrentList of pmc1008mpCtrllineLoopTransceiver Article
1.3.6.1.4.1.20044.47.6.3.218.1Rowpmc1008mpCtrllineLoopTransceiverEntrynot-accessiblecurrentRow definition for the pmc1008mpCtrllineLoopTransceiver table
1.3.6.1.4.1.20044.47.6.3.218.1.1Columnpmc1008mpCtrllineLoopTransceiverIndexread-onlycurrentIndex definition for the pmc1008mpCtrllineLoopTransceiver table
1.3.6.1.4.1.20044.47.6.3.218.1.2Columnpmc1008mpCtrllineLoopTransceiverPortnread-writecurrentLine Terminal Loopback :This OID operates a Line Terminal Loopback, looping line input signal on the line output port. The loop is located on all client transc…
1.3.6.1.4.1.20044.47.6.3.335Tablepmc1008mpCtrllineResetAllCountTablenot-accessiblecurrentList of pmc1008mpCtrllineResetAllCount Article
1.3.6.1.4.1.20044.47.6.3.335.1Rowpmc1008mpCtrllineResetAllCountEntrynot-accessiblecurrentRow definition for the pmc1008mpCtrllineResetAllCount table
1.3.6.1.4.1.20044.47.6.3.335.1.1Columnpmc1008mpCtrllineResetAllCountIndexread-onlycurrentIndex definition for the pmc1008mpCtrllineResetAllCount table
1.3.6.1.4.1.20044.47.6.3.335.1.2Columnpmc1008mpCtrllineResetAllCountsPortnread-writecurrentLine Counters Reset :This OID resets every counter on the line port <Help> This control operates a reset on the statistics current ,previous and history line p…
1.3.6.1.4.1.20044.47.7Nodepmc1008mpri
1.3.6.1.4.1.20044.47.7.1Nodepmc1008mpriTable
1.3.6.1.4.1.20044.47.7.1.1Tablepmc1008mpRinvSfpTablenot-accessiblecurrentList of the SFPs on the selected module
1.3.6.1.4.1.20044.47.7.1.1.1Rowpmc1008mpRinvSfpEntrynot-accessiblecurrentRow definition for the SFP table
1.3.6.1.4.1.20044.47.7.1.1.1.1Columnpmc1008mpRinvSfpIndexread-onlycurrentIndex for SFP table
1.3.6.1.4.1.20044.47.7.1.1.1.2Columnpmc1008mpRinvsfpread-onlycurrentInventory for the SFP: This OID contains the inventory for the SFP
1.3.6.1.4.1.20044.47.7.1.2Tablepmc1008mpRinvLineTablenot-accessiblecurrentList of the XFPs on the selected module
1.3.6.1.4.1.20044.47.7.1.2.1Rowpmc1008mpRinvLineEntrynot-accessiblecurrentRow definition for the XFP table
1.3.6.1.4.1.20044.47.7.1.2.1.1Columnpmc1008mpRinvLineIndexread-onlycurrentIndex for XFP table
1.3.6.1.4.1.20044.47.7.1.2.1.2Columnpmc1008mpRinvxfpLineread-onlycurrentInventory for the XFP: This OID contains the inventory for the XFP
1.3.6.1.4.1.20044.47.7.2Scalarpmc1008mpRinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.47.7.3Scalarpmc1008mpRinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.47.7.4Scalarpmc1008mpRinvModulePlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.47.7.5Scalarpmc1008mpRinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.47.7.6Scalarpmc1008mpRinvGwPlatformread-onlycurrentGW platform desciption: This OID contains the description of the Gateware platform.
1.3.6.1.4.1.20044.47.8Nodepmc1008mpdownload
1.3.6.1.4.1.20044.47.8.1Nodepmc1008mpDwlOther
1.3.6.1.4.1.20044.47.8.1.0Nodepmc1008mpDwlrestartProcess
1.3.6.1.4.1.20044.47.8.1.0.1Scalarpmc1008mpDwlWarmRestartProcessedread-onlycurrentWarm Restart :This OID indicates that the module last restart was a Warm RESTART
1.3.6.1.4.1.20044.47.8.1.0.2Scalarpmc1008mpDwlColdRestartProcessedread-onlycurrentCold Restart :This OID indicates that the module last restart was a Cold RESTART
1.3.6.1.4.1.20044.47.8.1.1Nodepmc1008mpDwlswBanksUsed
1.3.6.1.4.1.20044.47.8.1.1.1Scalarpmc1008mpDwlSwBank1Usedread-onlycurrentSW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby
1.3.6.1.4.1.20044.47.8.1.1.2Scalarpmc1008mpDwlSwBank2Usedread-onlycurrentSW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby
1.3.6.1.4.1.20044.47.8.1.1.5Scalarpmc1008mpDwlSwBank1Notemptyread-onlycurrentSW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package
1.3.6.1.4.1.20044.47.8.1.1.6Scalarpmc1008mpDwlSwBank2Notemptyread-onlycurrentSW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package
1.3.6.1.4.1.20044.47.8.1.2Nodepmc1008mpDwlgwBanksUsed
1.3.6.1.4.1.20044.47.8.1.2.1Scalarpmc1008mpDwlGwBank1Usedread-onlycurrentGW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby
1.3.6.1.4.1.20044.47.8.1.2.2Scalarpmc1008mpDwlGwBank2Usedread-onlycurrentGW bank 2 active :This OID indicates the module is working on GW bank 2
1.3.6.1.4.1.20044.47.8.1.2.3Scalarpmc1008mpDwlGwBank3Usedread-onlycurrentGW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby
1.3.6.1.4.1.20044.47.8.1.2.4Scalarpmc1008mpDwlGwBank4Usedread-onlycurrentGW bank 4 active :This OID indicates the module is working on GW bank 4
1.3.6.1.4.1.20044.47.8.1.2.5Scalarpmc1008mpDwlGwBank1Notemptyread-onlycurrentGW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package
1.3.6.1.4.1.20044.47.8.1.2.6Scalarpmc1008mpDwlGwBank2Notemptyread-onlycurrentGW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2
1.3.6.1.4.1.20044.47.8.1.2.7Scalarpmc1008mpDwlGwBank3Notemptyread-onlycurrentGW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package
1.3.6.1.4.1.20044.47.8.1.2.8Scalarpmc1008mpDwlGwBank4Notemptyread-onlycurrentGW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4
1.3.6.1.4.1.20044.47.8.2Nodepmc1008mpDwlClient
1.3.6.1.4.1.20044.47.8.3Nodepmc1008mpDwlLine
1.3.6.1.4.1.20044.47.9Nodepmc1008mpConfig
1.3.6.1.4.1.20044.47.9.1Nodepmc1008mpCfgAccessCAisCsf
1.3.6.1.4.1.20044.47.9.1.1Tablepmc1008mpCfgClientcaiscsfTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.47.9.1.1.1Rowpmc1008mpCfgClientcaiscsfEntrynot-accessiblecurrentRow definition for the accessCAisCsf table
1.3.6.1.4.1.20044.47.9.1.1.1.1Columnpmc1008mpCfgClientcaiscsfIndexread-onlycurrentIndex definition for the clientcaiscsf table
1.3.6.1.4.1.20044.47.9.1.1.1.3Columnpmc1008mpCfgCAisModePortnread-writecurrentCAIS mode on Client Port :This register enables/disables port laser shutdown on CAIS insertion condition
1.3.6.1.4.1.20044.47.9.1.1.1.9Columnpmc1008mpCfgUpAccessioAlmPortnread-writecurrentCSF contributors on Client Port :This register configures the contributors to upstream CSF insertion on the port.
1.3.6.1.4.1.20044.47.9.1.1.1.10Columnpmc1008mpCfgUpMapperDeAlmPortnread-writecurrentCSF contributors on Client Port :This register configures the contributors to upstream CSF insertion on the port.
1.3.6.1.4.1.20044.47.9.1.1.1.17Columnpmc1008mpCfgDownAccessioAlmPortnread-writecurrentCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port.
1.3.6.1.4.1.20044.47.9.1.1.1.18Columnpmc1008mpCfgDownMapperDeAlmPortnread-writecurrentCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port.
1.3.6.1.4.1.20044.47.9.1.1.1.19Columnpmc1008mpCfgDownDfrmAlmPortnread-writecurrentCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port.
1.3.6.1.4.1.20044.47.9.1.1.1.20Columnpmc1008mpCfgDownLineSyncAlarmsPortnread-writedeprecatedCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on port.
1.3.6.1.4.1.20044.47.9.2Nodepmc1008mpCfgStartup
1.3.6.1.4.1.20044.47.9.2.1Tablepmc1008mpCfgClientStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.47.9.2.1.1Rowpmc1008mpCfgClientStartupEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.47.9.2.1.1.1Columnpmc1008mpCfgClientStartupIndexread-onlycurrentIndex definition for the clientStartup table
1.3.6.1.4.1.20044.47.9.2.1.1.3Columnpmc1008mpCfgSystConfPortPortnread-writecurrentDefault Settings on Client Port :This register configures the default initialisation settings on the port.
1.3.6.1.4.1.20044.47.9.2.1.1.4Columnpmc1008mpCfgNetConfPortPortnread-writecurrentDefault Protocol on Client Port :This register configures the default initialisation protocol on the port.
1.3.6.1.4.1.20044.47.9.2.1.1.5Columnpmc1008mpCfgAdddropConfPortPortnread-writedeprecatedDefault Add&Drop mode on Client Port :This register configures the default Add&Drop mode on the port.
1.3.6.1.4.1.20044.47.9.2.2Nodepmc1008mptablelineStartup
1.3.6.1.4.1.20044.47.9.2.2.2Scalarpmc1008mpCfgsystConfLine1read-writecurrentDefault Settings on Line 1 :This register configures the default initialisation settings on Line port 1.
1.3.6.1.4.1.20044.47.9.2.2.5Scalarpmc1008mpCfglineOptions1read-writecurrentDefault Options on Active Line Port :This register configures the default options on the active line port
1.3.6.1.4.1.20044.47.9.2.2.6Scalarpmc1008mpCfgsystConfLine2read-writecurrentDefault Settings on Line 2 :This register configures the default initialisation settings on Line port 2.
1.3.6.1.4.1.20044.47.9.2.2.7Scalarpmc1008mpCfglineSelectionread-writecurrentDefault Settings of active line :This register configures the start up active line.
1.3.6.1.4.1.20044.47.9.2.2.9Scalarpmc1008mpCfglineOptions2read-writedeprecatedDefault Options on Active Line Port :This register configures the default options on the active line port
1.3.6.1.4.1.20044.47.9.2.3Tablepmc1008mpCfgXfpTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.47.9.2.3.1Rowpmc1008mpCfgXfpEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.47.9.2.3.1.1Columnpmc1008mpCfgXfpIndexread-onlycurrentIndex definition for the xfp table
1.3.6.1.4.1.20044.47.9.2.3.1.3Columnpmc1008mpCfgSystConfXfpPortnread-writecurrentDefault settings on XFP Port :This register configures the default initialisation settings on XFP port.
1.3.6.1.4.1.20044.47.9.2.3.1.4Columnpmc1008mpCfgDataRateConfXfpPortnread-writedeprecated:
1.3.6.1.4.1.20044.47.9.2.4Tablepmc1008mpCfgOtxtlhTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.47.9.2.4.1Rowpmc1008mpCfgOtxtlhEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.47.9.2.4.1.1Columnpmc1008mpCfgOtxtlhIndexread-onlycurrentIndex definition for the otxtlh table
1.3.6.1.4.1.20044.47.9.2.4.1.3Columnpmc1008mpCfgLineOtxMiscPortnread-writecurrentDefault Line OTX TLH miscellaneous :This register configures the start-up miscellaneous mode of the Line OTX TLH
1.3.6.1.4.1.20044.47.9.2.4.1.4Columnpmc1008mpCfgLineDitherRatePortnread-writecurrentDefault Line OTX TLH FM amplitude :This register configures the start-up width of the frequency modulation of the Line OTX TLH
1.3.6.1.4.1.20044.47.9.2.4.1.5Columnpmc1008mpCfgLineDitherFhzPortnread-writecurrentDefault Line OTX TLH FM frequency :This register configures the start-up frequency of the frequency modulation of the Line OTX TLH
1.3.6.1.4.1.20044.47.9.2.4.1.6Columnpmc1008mpCfgLinePwrLaserPortnread-writecurrentDefaut Line OTX TLH output Power :This register configures the start-up output power of the Line OTX TLH (Unit = dBm)
1.3.6.1.4.1.20044.47.9.2.4.1.7Columnpmc1008mpCfgLineFCurrentPortnread-writecurrentDefault Line OTX TLH Channel :This register configures the start-up laser channel of the Line OTX TLH
1.3.6.1.4.1.20044.47.9.2.4.1.8Columnpmc1008mpCfgLineGridCurrentPortnread-writecurrentDefault Line OTX TLH Grid :This register configures the start-up laser grid of the Line OTX TLH
1.3.6.1.4.1.20044.47.9.2.4.1.9Columnpmc1008mpCfgFPortnread-writecurrentDefault Line OTX TLH lowest Freq :This register configures the start-up lowest frequency supported on the Line OTX TLH
1.3.6.1.4.1.20044.47.9.2.4.1.10Columnpmc1008mpCfgReservedPortnread-writedeprecated:
1.3.6.1.4.1.20044.47.9.2.4.1.11Columnpmc1008mpCfgLinePhotodiodeModePortnread-writecurrentDefault Line OTX TLH APD mode :This register configures the start-up APD mode of the Line OTX TLH
1.3.6.1.4.1.20044.47.9.2.4.1.12Columnpmc1008mpCfgLinePhotodiodeValuePortnread-writecurrentDefault Line OTX TLH APD atten. :This register configures the start-up APD attenuation on the Line OTX TLH
1.3.6.1.4.1.20044.47.9.3Nodepmc1008mpCfgOther
1.3.6.1.4.1.20044.47.9.3.1Nodepmc1008mptablemoduleOther
1.3.6.1.4.1.20044.47.9.3.1.2Scalarpmc1008mpCfgmoderead-writecurrentDefault settings on Module :This register selects the DCC configuration of the PM
1.3.6.1.4.1.20044.47.9.4Nodepmc1008mpCfgLabels
1.3.6.1.4.1.20044.47.9.4.1Tablepmc1008mpCfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.47.9.4.1.1Rowpmc1008mpCfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.47.9.4.1.1.1Columnpmc1008mpCfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.47.9.4.1.1.3Columnpmc1008mpCfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.47.9.4.2Tablepmc1008mpCfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.47.9.4.2.1Rowpmc1008mpCfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.47.9.4.2.1.1Columnpmc1008mpCfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.47.9.4.2.1.3Columnpmc1008mpCfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.47.9.5Nodepmc1008mpCfgStartuptimeslotsline1
1.3.6.1.4.1.20044.47.9.5.1Tablepmc1008mpCfgTimeslotsportsline1Tablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.47.9.5.1.1Rowpmc1008mpCfgTimeslotsportsline1Entrynot-accessiblecurrentRow definition for the startuptimeslotsline1 table
1.3.6.1.4.1.20044.47.9.5.1.1.1Columnpmc1008mpCfgTimeslotsportsline1Indexread-onlycurrentIndex definition for the timeslotsportsline1 table
1.3.6.1.4.1.20044.47.9.5.1.1.3Columnpmc1008mpCfgLine1Timeslotb2PortPortnread-writecurrentPort Defaut Time Slot allocation (MSB) on Line1 :This register configures the start-up timeslots allocation on the port (MSB)
1.3.6.1.4.1.20044.47.9.5.1.1.4Columnpmc1008mpCfgLine1Timeslotb1PortPortnread-writecurrentPort Defaut Time Slot allocation (LSB) on Line1 :This register configures the start-up timeslots allocation on the port (LSB)
1.3.6.1.4.1.20044.47.9.5.1.1.5Columnpmc1008mpCfgLine1ProtocolPortPortnread-writecurrentPort Defaut Protocol on Line1 :This register configures the start-up protocol on the port
1.3.6.1.4.1.20044.47.9.6Nodepmc1008mpCfgStartuptimeslotsline2
1.3.6.1.4.1.20044.47.9.6.1Tablepmc1008mpCfgTimeslotsportsline2Tablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.47.9.6.1.1Rowpmc1008mpCfgTimeslotsportsline2Entrynot-accessiblecurrentRow definition for the startuptimeslotsline2 table
1.3.6.1.4.1.20044.47.9.6.1.1.1Columnpmc1008mpCfgTimeslotsportsline2Indexread-onlycurrentIndex definition for the timeslotsportsline2 table
1.3.6.1.4.1.20044.47.9.6.1.1.3Columnpmc1008mpCfgLine2Timeslotb2PortPortnread-writecurrentPort Defaut Time Slot allocation (MSB) on Line2 :This register configures the start-up timeslots allocation on the port (MSB)
1.3.6.1.4.1.20044.47.9.6.1.1.4Columnpmc1008mpCfgLine2Timeslotb1PortPortnread-writecurrentPort Defaut Time Slot allocation (LSB) on Line2 :This register configures the start-up timeslots allocation on the port (LSB)
1.3.6.1.4.1.20044.47.9.6.1.1.5Columnpmc1008mpCfgLine2ProtocolPortPortnread-writecurrentPort Defaut Protocol on Line2 :This register configures the start-up protocol on the port
1.3.6.1.4.1.20044.47.9.7Nodepmc1008mpCfgStartuptimeslotspassthroughline1
1.3.6.1.4.1.20044.47.9.7.1Tablepmc1008mpCfgTimeslotspassthroughline1Tablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.47.9.7.1.1Rowpmc1008mpCfgTimeslotspassthroughline1Entrynot-accessiblecurrentRow definition for the startuptimeslotspassthroughline1 table
1.3.6.1.4.1.20044.47.9.7.1.1.1Columnpmc1008mpCfgTimeslotspassthroughline1Indexread-onlycurrentIndex definition for the timeslotspassthroughline1 table
1.3.6.1.4.1.20044.47.9.7.1.1.3Columnpmc1008mpCfgLine1Timeslotb2PassthroughPortnread-writecurrentPort Defaut PassThrough Time Slot allocation (MSB) on Line1 :This register configures the start-up timeslots allocation on the port (MSB)
1.3.6.1.4.1.20044.47.9.7.1.1.4Columnpmc1008mpCfgLine1Timeslotb1PassthroughPortnread-writecurrentPort Defaut PassThroughTime Slot allocation (LSB) on Line1 :This register configures the start-up timeslots allocation on the port (LSB)
1.3.6.1.4.1.20044.47.9.7.1.1.5Columnpmc1008mpCfgLine1ProtocolPassthroughPortnread-writecurrentPort Defaut PassThrough Protocol on Line1 :This register configures the start-up protocol on the port
1.3.6.1.4.1.20044.47.9.8Nodepmc1008mpCfgStartuptimeslotspassthroughline2
1.3.6.1.4.1.20044.47.9.8.1Tablepmc1008mpCfgTimeslotspassthroughline2Tablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.47.9.8.1.1Rowpmc1008mpCfgTimeslotspassthroughline2Entrynot-accessiblecurrentRow definition for the startuptimeslotspassthroughline2 table
1.3.6.1.4.1.20044.47.9.8.1.1.1Columnpmc1008mpCfgTimeslotspassthroughline2Indexread-onlycurrentIndex definition for the timeslotspassthroughline2 table
1.3.6.1.4.1.20044.47.9.8.1.1.3Columnpmc1008mpCfgLine2Timeslotb2PassthroughPortnread-writecurrentPort Defaut PassThrough Time Slot allocation (MSB) on Line2 :This register configures the start-up timeslots allocation on the port (MSB)
1.3.6.1.4.1.20044.47.9.8.1.1.4Columnpmc1008mpCfgLine2Timeslotb1PassthroughPortnread-writecurrentPort Defaut PassThroughTime Slot allocation (LSB) on Line2 :This register configures the start-up timeslots allocation on the port (LSB)
1.3.6.1.4.1.20044.47.9.8.1.1.5Columnpmc1008mpCfgLine2ProtocolPassthroughPortnread-writecurrentPort Defaut PassThrough Protocol on Line2 :This register configures the start-up protocol on the port
1.3.6.1.4.1.20044.47.9.9Nodepmc1008mpCfgStartuptablefive
1.3.6.1.4.1.20044.47.9.9.1Tablepmc1008mpCfgOtxtlhcapabilitiesTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.47.9.9.1.1Rowpmc1008mpCfgOtxtlhcapabilitiesEntrynot-accessiblecurrentRow definition for the startuptablefive table
1.3.6.1.4.1.20044.47.9.9.1.1.1Columnpmc1008mpCfgOtxtlhcapabilitiesIndexread-onlycurrentIndex definition for the otxtlhcapabilities table
1.3.6.1.4.1.20044.47.9.9.1.1.3Columnpmc1008mpCfgComponentTypePortnread-onlycurrentComponent parameters :This OID defines the component parameters
1.3.6.1.4.1.20044.47.9.9.1.1.4Columnpmc1008mpCfgMiscellaneousPortnread-onlycurrentMiscellaneous default settings :This OID defines the miscellaneous parameters
1.3.6.1.4.1.20044.47.9.9.1.1.5Columnpmc1008mpCfgFirstChannelPortnread-onlycurrentNumber of the first channel of the component :This OID defines the first channel number of the PM
1.3.6.1.4.1.20044.47.9.9.1.1.6Columnpmc1008mpCfgLastChannelPortnread-onlycurrentNumber of the last channel of the component :This OID defines the last channel number of the PM
1.3.6.1.4.1.20044.47.9.9.1.1.7Columnpmc1008mpCfgGridPortnread-onlycurrentGrid value of the component :This OID defines the grid of the PM
1.3.6.1.4.1.20044.47.9.257Scalarpmc1008mpCfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.47.10Nodepmc1008mptraps
1.3.6.1.4.1.20044.47.10.2Scalarpmc1008mptrapPortNumberread-onlycurrentLast port which generates a trap
1.3.6.1.4.1.20044.47.10.3Scalarpmc1008mptrapLineNumberread-onlycurrentLast Line which generates a trap
1.3.6.1.4.1.20044.47.10.4Scalarpmc1008mptrapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.47.10.30Notificationpmc1008mpLineTrapNotUrgentGoesOncurrentNot urgent Line default is activated
1.3.6.1.4.1.20044.47.10.31Notificationpmc1008mpLineTrapNotUrgentGoesOffcurrentNot urgent Line default disappeared
1.3.6.1.4.1.20044.47.10.32Notificationpmc1008mpLineTrapUrgentGoesOncurrentUrgent Line default is activated
1.3.6.1.4.1.20044.47.10.33Notificationpmc1008mpLineTrapUrgentGoesOffcurrentUrgent Line default disappeared
1.3.6.1.4.1.20044.47.10.34Notificationpmc1008mpLineTrapCritGoesOncurrentCritical Line default is activated
1.3.6.1.4.1.20044.47.10.35Notificationpmc1008mpLineTrapCritGoesOffcurrentCritical Line default disappeared
1.3.6.1.4.1.20044.47.10.40Notificationpmc1008mpClientTrapNotUrgentGoesOncurrentNot urgent client default is activated
1.3.6.1.4.1.20044.47.10.41Notificationpmc1008mpClientTrapNotUrgentGoesOffcurrentNot urgent client default disappeared
1.3.6.1.4.1.20044.47.10.42Notificationpmc1008mpClientTrapUrgentGoesOncurrentUrgent client default is activated
1.3.6.1.4.1.20044.47.10.43Notificationpmc1008mpClientTrapUrgentGoesOffcurrentUrgent client default disappeared
1.3.6.1.4.1.20044.47.10.44Notificationpmc1008mpClientTrapCritGoesOncurrentCritical client default is activated
1.3.6.1.4.1.20044.47.10.45Notificationpmc1008mpClientTrapCritGoesOffcurrentCritical client default disappeared
1.3.6.1.4.1.20044.47.10.50Notificationpmc1008mpPowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.47.10.51Notificationpmc1008mpPowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared
1.3.6.1.4.1.20044.47.11Nodepmc1008mpMonitoring
1.3.6.1.4.1.20044.47.11.1Nodepmc1008mpMonOther
1.3.6.1.4.1.20044.47.11.1.1Nodepmc1008mpMonSync
1.3.6.1.4.1.20044.47.11.1.1.257Scalarpmc1008mpPerfEnableread-writecurrentPerf. Mon. Enable :This OID enables the Performance Monitoring application
1.3.6.1.4.1.20044.47.11.1.1.259Scalarpmc1008mpPerf15minSyncread-writecurrentPerf. Mon. 15-min sync. :This OID must be used in external synchronisation mode only to send a 15-min synchronisation command
1.3.6.1.4.1.20044.47.11.1.1.260Scalarpmc1008mpPerf24hSyncread-writecurrentPerf. Mon. 24-hours sync. :This OID must be used in external synchronisation mode only to send a 24-hours synchronisation command
1.3.6.1.4.1.20044.47.11.1.2Nodepmc1008mpMonTimeStamp
1.3.6.1.4.1.20044.47.11.1.2.1Scalarpmc1008mpPerf15MinShortread-writecurrent15-min period is short :This OID indicates that the 15-min period lasts less than 890 seconds
1.3.6.1.4.1.20044.47.11.1.2.2Scalarpmc1008mpPerf15MinLongread-writecurrent15-min period is long :This OID indicates that the 15-min period lasts more than 910 seconds
1.3.6.1.4.1.20044.47.11.1.2.5Scalarpmc1008mpPerf24HoursShortread-writecurrent24-hours period is short :This OID indicates that 24-hours period lasts less than 86390 seconds
1.3.6.1.4.1.20044.47.11.1.2.6Scalarpmc1008mpPerf24HoursLongread-writecurrent24-hours period is long :This OID indicates that 24-hours period lasts more than 86410 seconds
1.3.6.1.4.1.20044.47.11.1.2.7Scalarpmc1008mpPerfCurrent15MinElapsedTimeread-writecurrentCurrent 15min period Elapsed Time :This OID gives the number of seconds elapsed in the current 15-minutes period
1.3.6.1.4.1.20044.47.11.1.2.8Scalarpmc1008mpPerfCurrent24HoursElapsedTimeread-writecurrentCurrent 24hours period Elapsed Time :This OID gives the number of seconds elapsed in the current 24-hours period
1.3.6.1.4.1.20044.47.11.1.3Nodepmc1008mpMonRmon
1.3.6.1.4.1.20044.47.11.1.3.359Scalarpmc1008mpMonCountersResetread-writecurrentRMON Counters Reset:This OID resets and restarts all the RMON counters
1.3.6.1.4.1.20044.47.11.1.3.360Scalarpmc1008mpMonCountersStopread-writecurrentRMON Counters stop:This OID stops all the RMON counters
1.3.6.1.4.1.20044.47.11.2Nodepmc1008mpMonClient
1.3.6.1.4.1.20044.47.11.2.4Nodepmc1008mpMonClientRmonCounter
1.3.6.1.4.1.20044.47.11.2.4.16Tablepmc1008mpMonupRmonByteCntTablenot-accessiblecurrentList of pmc1008mpMonupRmonByteCnt Article
1.3.6.1.4.1.20044.47.11.2.4.16.1Rowpmc1008mpMonupRmonByteCntEntrynot-accessiblecurrentRow definition for the pmc1008mpMonupRmonByteCnt table
1.3.6.1.4.1.20044.47.11.2.4.16.1.1Columnpmc1008mpMonupRmonByteCntIndexread-onlycurrentIndex definition for the pmc1008mpMonupRmonByteCnt table
1.3.6.1.4.1.20044.47.11.2.4.16.1.2Columnpmc1008mpMonupRmonByteCntValuePortnread-onlycurrentBytes Counter On Client Input :This counter is increased each time a data byte is received on the client port <Help> This counter gives the number of bytes rec…
1.3.6.1.4.1.20044.47.11.2.4.16.1.3Columnpmc1008mpMonupRmonByteCntErrorPortnread-onlycurrentBytes Counter Error :This OID when set indicates the Bytes counter value is invalid on clinet port
1.3.6.1.4.1.20044.47.11.2.4.16.1.4Columnpmc1008mpMonupRmonByteCntOverloadPortnread-onlycurrentBytes Counter Overload :This OID when set indicates a Bytes counter overload on client port
1.3.6.1.4.1.20044.47.11.2.4.24Tablepmc1008mpMonupRmonCrcErrorCntTablenot-accessiblecurrentList of pmc1008mpMonupRmonCrcErrorCnt Article
1.3.6.1.4.1.20044.47.11.2.4.24.1Rowpmc1008mpMonupRmonCrcErrorCntEntrynot-accessiblecurrentRow definition for the pmc1008mpMonupRmonCrcErrorCnt table
1.3.6.1.4.1.20044.47.11.2.4.24.1.1Columnpmc1008mpMonupRmonCrcErrorCntIndexread-onlycurrentIndex definition for the pmc1008mpMonupRmonCrcErrorCnt table
1.3.6.1.4.1.20044.47.11.2.4.24.1.2Columnpmc1008mpMonupRmonCrcErrorCntValuePortnread-onlycurrentCRC Errors Counter On Client Input :This counter is increased each time a CRC error is detected on the client port <Help> This counter gives the number of CRC …
1.3.6.1.4.1.20044.47.11.2.4.24.1.3Columnpmc1008mpMonupRmonCrcErrorCntErrorPortnread-onlycurrentCRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on clinet port
1.3.6.1.4.1.20044.47.11.2.4.24.1.4Columnpmc1008mpMonupRmonCrcErrorCntOverloadPortnread-onlycurrentCRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on client port
1.3.6.1.4.1.20044.47.11.2.4.32Tablepmc1008mpMonupRmonPacketsCntTablenot-accessiblecurrentList of pmc1008mpMonupRmonPacketsCnt Article
1.3.6.1.4.1.20044.47.11.2.4.32.1Rowpmc1008mpMonupRmonPacketsCntEntrynot-accessiblecurrentRow definition for the pmc1008mpMonupRmonPacketsCnt table
1.3.6.1.4.1.20044.47.11.2.4.32.1.1Columnpmc1008mpMonupRmonPacketsCntIndexread-onlycurrentIndex definition for the pmc1008mpMonupRmonPacketsCnt table
1.3.6.1.4.1.20044.47.11.2.4.32.1.2Columnpmc1008mpMonupRmonPacketsCntValuePortnread-onlycurrentPackets Counter On Client Input :This counter is increased each time a packet is received on the client port <Help> This counter gives the number of packets re…
1.3.6.1.4.1.20044.47.11.2.4.32.1.3Columnpmc1008mpMonupRmonPacketsCntErrorPortnread-onlycurrentPackets Counter Error :This OID when set indicates the Packets counter value is invalid on clinet port
1.3.6.1.4.1.20044.47.11.2.4.32.1.4Columnpmc1008mpMonupRmonPacketsCntOverloadPortnread-onlycurrentPackets Counter Overload :This OID when set indicates a Packets counter overload on client port
1.3.6.1.4.1.20044.47.11.2.4.40Tablepmc1008mpMonupRmonBroadcastCntTablenot-accessiblecurrentList of pmc1008mpMonupRmonBroadcastCnt Article
1.3.6.1.4.1.20044.47.11.2.4.40.1Rowpmc1008mpMonupRmonBroadcastCntEntrynot-accessiblecurrentRow definition for the pmc1008mpMonupRmonBroadcastCnt table
1.3.6.1.4.1.20044.47.11.2.4.40.1.1Columnpmc1008mpMonupRmonBroadcastCntIndexread-onlycurrentIndex definition for the pmc1008mpMonupRmonBroadcastCnt table
1.3.6.1.4.1.20044.47.11.2.4.40.1.2Columnpmc1008mpMonupRmonBroadcastCntValuePortnread-onlycurrentBroadcast Counter On Client Input :This counter is increased each time a broadcast packet is received on the client port <Help> This counter gives the number o…
1.3.6.1.4.1.20044.47.11.2.4.40.1.3Columnpmc1008mpMonupRmonBroadcastCntErrorPortnread-onlycurrentBroadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on clinet port
1.3.6.1.4.1.20044.47.11.2.4.40.1.4Columnpmc1008mpMonupRmonBroadcastCntOverloadPortnread-onlycurrentBroadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port
1.3.6.1.4.1.20044.47.11.2.4.48Tablepmc1008mpMonupRmonMulticastCntTablenot-accessiblecurrentList of pmc1008mpMonupRmonMulticastCnt Article
1.3.6.1.4.1.20044.47.11.2.4.48.1Rowpmc1008mpMonupRmonMulticastCntEntrynot-accessiblecurrentRow definition for the pmc1008mpMonupRmonMulticastCnt table
1.3.6.1.4.1.20044.47.11.2.4.48.1.1Columnpmc1008mpMonupRmonMulticastCntIndexread-onlycurrentIndex definition for the pmc1008mpMonupRmonMulticastCnt table
1.3.6.1.4.1.20044.47.11.2.4.48.1.2Columnpmc1008mpMonupRmonMulticastCntValuePortnread-onlycurrentMulticast Counter On Client Input :This counter is increased each time a Multicast packet is received on the client port <Help> This counter gives the number o…
1.3.6.1.4.1.20044.47.11.2.4.48.1.3Columnpmc1008mpMonupRmonMulticastCntErrorPortnread-onlycurrentMulticast Counter Error :This OID when set indicates the Multicast counter value is invalid on clinet port
1.3.6.1.4.1.20044.47.11.2.4.48.1.4Columnpmc1008mpMonupRmonMulticastCntOverloadPortnread-onlycurrentMulticast Counter Overload :This OID when set indicates a Multicast counter overload on client port
1.3.6.1.4.1.20044.47.11.2.16Tablepmc1008mpPerfTelecomClientCurrent15StatTablenot-accessiblecurrentList of pmc1008mpPerfTelecomClientCurrent15Stat Article
1.3.6.1.4.1.20044.47.11.2.16.1Rowpmc1008mpPerfTelecomClientCurrent15StatEntrynot-accessiblecurrentRow definition for the pmc1008mpPerfTelecomClientCurrent15Stat table
1.3.6.1.4.1.20044.47.11.2.16.1.1Columnpmc1008mpPerfTelecomClientCurrent15StatIndexread-onlycurrentIndex definition for the pmc1008mpPerfTelecomClientCurrent15Stat table
1.3.6.1.4.1.20044.47.11.2.16.1.2Columnpmc1008mpPerfTelecomClientCurrent15StatInvCvPortnread-onlycurrentCurrent 15-min CV counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.47.11.2.16.1.3Columnpmc1008mpPerfTelecomClientCurrent15StatCvValuePortnread-onlycurrentCurrent 15-min CV counter :This OID gives the current 15-min Coding Violation counter value
1.3.6.1.4.1.20044.47.11.2.16.1.4Columnpmc1008mpPerfTelecomClientCurrent15StatInvEsPortnread-onlycurrentCurrent 15-min ES counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.47.11.2.16.1.5Columnpmc1008mpPerfTelecomClientCurrent15StatEsValuePortnread-onlycurrentCurrent 15-min ES counter :This OID gives the current 15-min Errored Second counter value
1.3.6.1.4.1.20044.47.11.2.16.1.6Columnpmc1008mpPerfTelecomClientCurrent15StatInvSesPortnread-onlycurrentCurrent 15-min SES counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.47.11.2.16.1.7Columnpmc1008mpPerfTelecomClientCurrent15StatSesValuePortnread-onlycurrentCurrent 15-min SES counter :This OID gives the current 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.47.11.2.16.1.8Columnpmc1008mpPerfTelecomClientCurrent15StatInvSefsPortnread-onlycurrentCurrent 15-min SEFS counter inv. :This OID indicates that the current 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.47.11.2.16.1.9Columnpmc1008mpPerfTelecomClientCurrent15StatSefsValuePortnread-onlycurrentCurrent 15-min SEFS counter :This OID gives the current 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.47.11.2.16.1.10Columnpmc1008mpPerfTelecomClientCurrent15StatInvUasPortnread-onlycurrentCurrent 15-min UAS counter inv. :This OID indicates that the current 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.47.11.2.16.1.11Columnpmc1008mpPerfTelecomClientCurrent15StatUasValuePortnread-onlycurrentCurrent 15-min UAS counter :This OID gives the current 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.47.11.2.24Tablepmc1008mpPerfTelecomClientPast15StatHistoryPort1Tablenot-accessiblecurrentList of pmc1008mpPerfTelecomClientPast15StatHistory Article
1.3.6.1.4.1.20044.47.11.2.24.1Rowpmc1008mpPerfTelecomClientPast15StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pmc1008mpPerfTelecomClientPast15StatHistory table
1.3.6.1.4.1.20044.47.11.2.24.1.1Columnpmc1008mpPerfTelecomClientPast15StatHistoryPort1Indexread-onlycurrentIndex definition for the pmc1008mpPerfTelecomClientPast15StatHistory table
1.3.6.1.4.1.20044.47.11.2.24.1.2Columnpmc1008mpPerfTelecomClientPast15StatHistoryInvCvPort1read-onlycurrentPrevious 15-min CV counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.47.11.2.24.1.3Columnpmc1008mpPerfTelecomClientPast15StatHistoryCvValuePort1read-onlycurrentPrevious 15-min CV counter :This OID gives the previous 15-min Coding Violation counter value
1.3.6.1.4.1.20044.47.11.2.24.1.4Columnpmc1008mpPerfTelecomClientPast15StatHistoryInvEsPort1read-onlycurrentPrevious 15-min ES counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.47.11.2.24.1.5Columnpmc1008mpPerfTelecomClientPast15StatHistoryEsValuePort1read-onlycurrentPrevious 15-min ES counter :This OID gives the previous 15-min Errored Second counter value
1.3.6.1.4.1.20044.47.11.2.24.1.6Columnpmc1008mpPerfTelecomClientPast15StatHistoryInvSesPort1read-onlycurrentPrevious 15-min SES counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.47.11.2.24.1.7Columnpmc1008mpPerfTelecomClientPast15StatHistorySesValuePort1read-onlycurrentPrevious 15-min SES counter :This OID gives the previous 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.47.11.2.24.1.8Columnpmc1008mpPerfTelecomClientPast15StatHistoryInvSefsPort1read-onlycurrentPrevious 15-min SEFS counter inv. :This OID indicates that the previous 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.47.11.2.24.1.9Columnpmc1008mpPerfTelecomClientPast15StatHistorySefsValuePort1read-onlycurrentPrevious 15-min SEFS counter :This OID gives the previous 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.47.11.2.24.1.10Columnpmc1008mpPerfTelecomClientPast15StatHistoryInvUasPort1read-onlycurrentPrevious 15-min UAS counter inv. :This OID indicates that the previous 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.47.11.2.24.1.11Columnpmc1008mpPerfTelecomClientPast15StatHistoryUasValuePort1read-onlycurrentPrevious 15-min UAS counter :This OID gives the previous 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.47.11.2.32Tablepmc1008mpPerfTelecomClientCurrent24StatTablenot-accessiblecurrentList of pmc1008mpPerfTelecomClientCurrent24Stat Article
1.3.6.1.4.1.20044.47.11.2.32.1Rowpmc1008mpPerfTelecomClientCurrent24StatEntrynot-accessiblecurrentRow definition for the pmc1008mpPerfTelecomClientCurrent24Stat table
1.3.6.1.4.1.20044.47.11.2.32.1.1Columnpmc1008mpPerfTelecomClientCurrent24StatIndexread-onlycurrentIndex definition for the pmc1008mpPerfTelecomClientCurrent24Stat table
1.3.6.1.4.1.20044.47.11.2.32.1.2Columnpmc1008mpPerfTelecomClientCurrent24StatInvCvPortnread-onlycurrentCurrent 24-hours CV counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.47.11.2.32.1.3Columnpmc1008mpPerfTelecomClientCurrent24StatCvValuePortnread-onlycurrentCurrent 24-hours CV counter :This OID gives the current 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.47.11.2.32.1.4Columnpmc1008mpPerfTelecomClientCurrent24StatInvEsPortnread-onlycurrentCurrent 24-hours ES counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.47.11.2.32.1.5Columnpmc1008mpPerfTelecomClientCurrent24StatEsValuePortnread-onlycurrentCurrent 24-hours ES counter :This OID gives the current 24-hours Errored Second counter value
1.3.6.1.4.1.20044.47.11.2.32.1.6Columnpmc1008mpPerfTelecomClientCurrent24StatInvSesPortnread-onlycurrentCurrent 24-hours SES counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.47.11.2.32.1.7Columnpmc1008mpPerfTelecomClientCurrent24StatSesValuePortnread-onlycurrentCurrent 24-hours SES counter :This OID gives the current 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.47.11.2.32.1.8Columnpmc1008mpPerfTelecomClientCurrent24StatInvSefsPortnread-onlycurrentCurrent 24-hours SEFS counter inv. :This OID indicates that the current 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.47.11.2.32.1.9Columnpmc1008mpPerfTelecomClientCurrent24StatSefsValuePortnread-onlycurrentCurrent 24-hours SEFS counter :This OID gives the current 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.47.11.2.32.1.10Columnpmc1008mpPerfTelecomClientCurrent24StatInvUasPortnread-onlycurrentCurrent 24-hours UAS counter inv. :This OID indicates that the current 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.47.11.2.32.1.11Columnpmc1008mpPerfTelecomClientCurrent24StatUasValuePortnread-onlycurrentCurrent 24-hours UAS counter :This OID gives the current 24-hours UnAvailable Second counter value
1.3.6.1.4.1.20044.47.11.2.40Tablepmc1008mpPerfTelecomClientPast24StatHistoryPort1Tablenot-accessiblecurrentList of pmc1008mpPerfTelecomClientPast24StatHistory Article
1.3.6.1.4.1.20044.47.11.2.40.1Rowpmc1008mpPerfTelecomClientPast24StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pmc1008mpPerfTelecomClientPast24StatHistory table
1.3.6.1.4.1.20044.47.11.2.40.1.1Columnpmc1008mpPerfTelecomClientPast24StatHistoryPort1Indexread-onlycurrentIndex definition for the pmc1008mpPerfTelecomClientPast24StatHistory table
1.3.6.1.4.1.20044.47.11.2.40.1.2Columnpmc1008mpPerfTelecomClientPast24StatHistoryInvCvPort1read-onlycurrentPrevious 24-hours CV counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.47.11.2.40.1.3Columnpmc1008mpPerfTelecomClientPast24StatHistoryCvValuePort1read-onlycurrentPrevious 24-hours CV counter :This OID gives the previous 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.47.11.2.40.1.4Columnpmc1008mpPerfTelecomClientPast24StatHistoryInvEsPort1read-onlycurrentPrevious 24-hours ES counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.47.11.2.40.1.5Columnpmc1008mpPerfTelecomClientPast24StatHistoryEsValuePort1read-onlycurrentPrevious 24-hours ES counter :This OID gives the previous 24-hours Errored Second counter value
1.3.6.1.4.1.20044.47.11.2.40.1.6Columnpmc1008mpPerfTelecomClientPast24StatHistoryInvSesPort1read-onlycurrentPrevious 24-hours SES counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.47.11.2.40.1.7Columnpmc1008mpPerfTelecomClientPast24StatHistorySesValuePort1read-onlycurrentPrevious 24-hours SES counter :This OID gives the previous 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.47.11.2.40.1.8Columnpmc1008mpPerfTelecomClientPast24StatHistoryInvSefsPort1read-onlycurrentPrevious 24-hours SEFS counter inv. :This OID indicates that the previous 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.47.11.2.40.1.9Columnpmc1008mpPerfTelecomClientPast24StatHistorySefsValuePort1read-onlycurrentPrevious 24-hours SEFS counter :This OID gives the previous 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.47.11.2.40.1.10Columnpmc1008mpPerfTelecomClientPast24StatHistoryInvUasPort1read-onlycurrentPrevious 24-hours UAS counter inv. :This OID indicates that the previous 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.47.11.2.40.1.11Columnpmc1008mpPerfTelecomClientPast24StatHistoryUasValuePort1read-onlycurrentPrevious 24-hours UAS counter :This OID gives the previous 24-hours UnAvailable Second counter value
1.3.6.1.4.1.20044.47.11.2.256Tablepmc1008mpPerfDatacomClientCurrent15StatTablenot-accessiblecurrentList of pmc1008mpPerfDatacomClientCurrent15Stat Article
1.3.6.1.4.1.20044.47.11.2.256.1Rowpmc1008mpPerfDatacomClientCurrent15StatEntrynot-accessiblecurrentRow definition for the pmc1008mpPerfDatacomClientCurrent15Stat table
1.3.6.1.4.1.20044.47.11.2.256.1.1Columnpmc1008mpPerfDatacomClientCurrent15StatIndexread-onlycurrentIndex definition for the pmc1008mpPerfDatacomClientCurrent15Stat table
1.3.6.1.4.1.20044.47.11.2.256.1.2Columnpmc1008mpperfdatacomclientCurrent15StatInBytesCountInvPortnread-onlycurrentClient Current 15-min Input Bytes counter inv. :This OID indicates that the current 15-min Bytes counter is invalid
1.3.6.1.4.1.20044.47.11.2.256.1.3Columnpmc1008mpperfdatacomclientCurrent15StatInBytesCountPortnread-onlycurrentClient Current 15-min Input Bytes counter :This OID gives the current 15-min Bytes counter value
1.3.6.1.4.1.20044.47.11.2.256.1.4Columnpmc1008mpperfdatacomclientCurrent15StatInCrcCountInvPortnread-onlycurrentClient Current 15-min Input CRC counter inv. :This OID indicates that the current 15-min CRC counter is invalid
1.3.6.1.4.1.20044.47.11.2.256.1.5Columnpmc1008mpperfdatacomclientCurrent15StatInCrcCountPortnread-onlycurrentClient Current 15-min Input CRC counter :This OID gives the current 15-min CRC counter value
1.3.6.1.4.1.20044.47.11.2.256.1.8Columnpmc1008mpperfdatacomclientCurrent15StatInBroadcastCountInvPortnread-onlycurrentClient Current 15-min Input Broadcast counter inv. :This OID indicates that the current 15-min Broadcast counter is invalid
1.3.6.1.4.1.20044.47.11.2.256.1.9Columnpmc1008mpperfdatacomclientCurrent15StatInBroadcastCountPortnread-onlycurrentClient Current 15-min Input Broadcast counter :This OID gives the current 15-min Broadcast counter value
1.3.6.1.4.1.20044.47.11.2.256.1.10Columnpmc1008mpperfdatacomclientCurrent15StatInMulticastCountInvPortnread-onlycurrentClient Current 15-min Input Multicast counter inv. :This OID indicates that the current 15-min Multicast counter is invalid
1.3.6.1.4.1.20044.47.11.2.256.1.11Columnpmc1008mpperfdatacomclientCurrent15StatInMulticastCountPortnread-onlycurrentClient Current 15-min Input Multicast counter :This OID gives the current 15-min Multicast counter value
1.3.6.1.4.1.20044.47.11.2.256.1.20Columnpmc1008mpperfdatacomclientCurrent15StatInUnicastCountInvPortnread-onlycurrentClient Current 15-min Input Unicast counter inv. :This OID indicates that the current 15-min Unicast counter is invalid
1.3.6.1.4.1.20044.47.11.2.256.1.21Columnpmc1008mpperfdatacomclientCurrent15StatInUnicastCountPortnread-onlycurrentClient Current 15-min Input Unicast counter :This OID gives the current 15-min Unicast counter value
1.3.6.1.4.1.20044.47.11.2.256.1.22Columnpmc1008mpperfdatacomclientCurrent15StatInNonunicastCountInvPortnread-onlycurrentClient Current 15-min Input Non Unicast counter inv. :This OID indicates that the current 15-min Non unicast counter is invalid
1.3.6.1.4.1.20044.47.11.2.256.1.23Columnpmc1008mpperfdatacomclientCurrent15StatInNonunicastCountPortnread-onlycurrentClient Current 15-min Input Non Unicast counter :This OID gives the current 15-min Non Unicast counter value
1.3.6.1.4.1.20044.47.11.2.256.1.26Columnpmc1008mpperfdatacomclientCurrent15StatOutBytesCountInvPortnread-onlycurrentClient Current 15-min Output Bytes counter inv. :This OID indicates that the current 15-min Bytes counter is invalid
1.3.6.1.4.1.20044.47.11.2.256.1.27Columnpmc1008mpperfdatacomclientCurrent15StatOutBytesCountPortnread-onlycurrentClient Current 15-min Output Bytes counter :This OID gives the current 15-min Bytes counter value
1.3.6.1.4.1.20044.47.11.2.256.1.32Columnpmc1008mpperfdatacomclientCurrent15StatOutBroadcastCountInvPortnread-onlycurrentClient Current 15-min Output Broadcast counter inv. :This OID indicates that the current 15-min Broadcast counter is invalid
1.3.6.1.4.1.20044.47.11.2.256.1.33Columnpmc1008mpperfdatacomclientCurrent15StatOutBroadcastCountPortnread-onlycurrentClient Current 15-min Output Broadcast counter :This OID gives the current 15-min Broadcast counter value
1.3.6.1.4.1.20044.47.11.2.256.1.34Columnpmc1008mpperfdatacomclientCurrent15StatOutMulticastCountInvPortnread-onlycurrentClient Current 15-min Output Multicast counter inv. :This OID indicates that the current 15-min Multicast counter is invalid
1.3.6.1.4.1.20044.47.11.2.256.1.35Columnpmc1008mpperfdatacomclientCurrent15StatOutMulticastCountPortnread-onlycurrentClient Current 15-min Output Multicast counter :This OID gives the current 15-min Multicast counter value
1.3.6.1.4.1.20044.47.11.2.256.1.42Columnpmc1008mpperfdatacomclientCurrent15StatOutUnicastCountInvPortnread-onlycurrentClient Current 15-min Output Unicast counter inv. :This OID indicates that the current 15-min Unicast counter is invalid
1.3.6.1.4.1.20044.47.11.2.256.1.43Columnpmc1008mpperfdatacomclientCurrent15StatOutUnicastCountPortnread-onlycurrentClient Current 15-min Output Unicast counter :This OID gives the current 15-min Unicast counter value
1.3.6.1.4.1.20044.47.11.2.256.1.44Columnpmc1008mpperfdatacomclientCurrent15StatOutNonunicastCountInvPortnread-onlycurrentClient Current 15-min Output Non Unicast counter inv. :This OID indicates that the current 15-min Non Unicast counter is invalid
1.3.6.1.4.1.20044.47.11.2.256.1.45Columnpmc1008mpperfdatacomclientCurrent15StatOutNonunicastCountPortnread-onlycurrentClient Current 15-min Output Non Unicast counter :This OID gives the current 15-min Non Unicast counter value
1.3.6.1.4.1.20044.47.11.2.264Tablepmc1008mpPerfDatacomClientPast15StatHistoryPort1Tablenot-accessiblecurrentList of pmc1008mpPerfDatacomClientPast15StatHistory Article
1.3.6.1.4.1.20044.47.11.2.264.1Rowpmc1008mpPerfDatacomClientPast15StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pmc1008mpPerfDatacomClientPast15StatHistory table
1.3.6.1.4.1.20044.47.11.2.264.1.1Columnpmc1008mpPerfDatacomClientPast15StatHistoryPort1Indexread-onlycurrentIndex definition for the pmc1008mpPerfDatacomClientPast15StatHistory table
1.3.6.1.4.1.20044.47.11.2.264.1.2Columnpmc1008mpperfdatacomclientPast15StatInBytesCountInvPort1read-onlycurrentClient Past 15-min Input Bytes counter inv. :This OID indicates that the past 15-min Bytes counter is invalid
1.3.6.1.4.1.20044.47.11.2.264.1.3Columnpmc1008mpperfdatacomclientPast15StatInBytesCountPort1read-onlycurrentClient Past 15-min Input Bytes counter :This OID gives the past 15-min Bytes counter value
1.3.6.1.4.1.20044.47.11.2.264.1.4Columnpmc1008mpperfdatacomclientPast15StatInCrcCountInvPort1read-onlycurrentClient Past 15-min Input CRC counter inv. :This OID indicates that the past 15-min CRC counter is invalid
1.3.6.1.4.1.20044.47.11.2.264.1.5Columnpmc1008mpperfdatacomclientPast15StatInCrcCountPort1read-onlycurrentClient Past 15-min Input CRC counter :This OID gives the past 15-min CRC counter value
1.3.6.1.4.1.20044.47.11.2.264.1.8Columnpmc1008mpperfdatacomclientPast15StatInBroadcastCountInvPort1read-onlycurrentClient Past 15-min Input Broadcast counter inv. :This OID indicates that the past 15-min Broadcast counter is invalid
1.3.6.1.4.1.20044.47.11.2.264.1.9Columnpmc1008mpperfdatacomclientPast15StatInBroadcastCountPort1read-onlycurrentClient Past 15-min Input Broadcast counter :This OID gives the past 15-min Broadcast counter value
1.3.6.1.4.1.20044.47.11.2.264.1.10Columnpmc1008mpperfdatacomclientPast15StatInMulticastCountInvPort1read-onlycurrentClient Past 15-min Input Multicast counter inv. :This OID indicates that the past 15-min Multicast counter is invalid
1.3.6.1.4.1.20044.47.11.2.264.1.11Columnpmc1008mpperfdatacomclientPast15StatInMulticastCountPort1read-onlycurrentClient Past 15-min Input Multicast counter :This OID gives the past 15-min Multicast counter value
1.3.6.1.4.1.20044.47.11.2.264.1.20Columnpmc1008mpperfdatacomclientPast15StatInUnicastCountInvPort1read-onlycurrentClient Past 15-min Input Unicast counter inv. :This OID indicates that the past 15-min Unicast counter is invalid
1.3.6.1.4.1.20044.47.11.2.264.1.21Columnpmc1008mpperfdatacomclientPast15StatInUnicastCountPort1read-onlycurrentClient Past 15-min Input Unicast counter :This OID gives the past 15-min Unicast counter value
1.3.6.1.4.1.20044.47.11.2.264.1.22Columnpmc1008mpperfdatacomclientPast15StatInNonunicastCountInvPort1read-onlycurrentClient Past 15-min Input Non Unicast counter inv. :This OID indicates that the past 15-min Non unicast counter is invalid
1.3.6.1.4.1.20044.47.11.2.264.1.23Columnpmc1008mpperfdatacomclientPast15StatInNonunicastCountPort1read-onlycurrentClient Past 15-min Input Non Unicast counter :This OID gives the past 15-min Non Unicast counter value
1.3.6.1.4.1.20044.47.11.2.264.1.26Columnpmc1008mpperfdatacomclientPast15StatOutBytesCountInvPort1read-onlycurrentClient Past 15-min Output Bytes counter inv. :This OID indicates that the past 15-min Bytes counter is invalid
1.3.6.1.4.1.20044.47.11.2.264.1.27Columnpmc1008mpperfdatacomclientPast15StatOutBytesCountPort1read-onlycurrentClient Past 15-min Output Bytes counter :This OID gives the past 15-min Bytes counter value
1.3.6.1.4.1.20044.47.11.2.264.1.32Columnpmc1008mpperfdatacomclientPast15StatOutBroadcastCountInvPort1read-onlycurrentClient Past 15-min Output Broadcast counter inv. :This OID indicates that the past 15-min Broadcast counter is invalid
1.3.6.1.4.1.20044.47.11.2.264.1.33Columnpmc1008mpperfdatacomclientPast15StatOutBroadcastCountPort1read-onlycurrentClient Past 15-min Output Broadcast counter :This OID gives the past 15-min Broadcast counter value
1.3.6.1.4.1.20044.47.11.2.264.1.34Columnpmc1008mpperfdatacomclientPast15StatOutMulticastCountInvPort1read-onlycurrentClient Past 15-min Output Multicast counter inv. :This OID indicates that the past 15-min Multicast counter is invalid
1.3.6.1.4.1.20044.47.11.2.264.1.35Columnpmc1008mpperfdatacomclientPast15StatOutMulticastCountPort1read-onlycurrentClient Past 15-min Output Multicast counter :This OID gives the past 15-min Multicast counter value
1.3.6.1.4.1.20044.47.11.2.264.1.42Columnpmc1008mpperfdatacomclientPast15StatOutUnicastCountInvPort1read-onlycurrentClient Past 15-min Output Unicast counter inv. :This OID indicates that the past 15-min Unicast counter is invalid
1.3.6.1.4.1.20044.47.11.2.264.1.43Columnpmc1008mpperfdatacomclientPast15StatOutUnicastCountPort1read-onlycurrentClient Past 15-min Output Unicast counter :This OID gives the past 15-min Unicast counter value
1.3.6.1.4.1.20044.47.11.2.264.1.44Columnpmc1008mpperfdatacomclientPast15StatOutNonunicastCountInvPort1read-onlycurrentClient Past 15-min Output Non Unicast counter inv. :This OID indicates that the past 15-min Non Unicast counter is invalid
1.3.6.1.4.1.20044.47.11.2.264.1.45Columnpmc1008mpperfdatacomclientPast15StatOutNonunicastCountPort1read-onlycurrentClient Past 15-min Output Non Unicast counter :This OID gives the past 15-min Non Unicast counter value
1.3.6.1.4.1.20044.47.11.2.272Tablepmc1008mpPerfDatacomClientCurrent24StatTablenot-accessiblecurrentList of pmc1008mpPerfDatacomClientCurrent24Stat Article
1.3.6.1.4.1.20044.47.11.2.272.1Rowpmc1008mpPerfDatacomClientCurrent24StatEntrynot-accessiblecurrentRow definition for the pmc1008mpPerfDatacomClientCurrent24Stat table
1.3.6.1.4.1.20044.47.11.2.272.1.1Columnpmc1008mpPerfDatacomClientCurrent24StatIndexread-onlycurrentIndex definition for the pmc1008mpPerfDatacomClientCurrent24Stat table
1.3.6.1.4.1.20044.47.11.2.272.1.2Columnpmc1008mpperfdatacomclientCurrent24StatInBytesCountInvPortnread-onlycurrentClient Current 24-hours Input Bytes counter inv. :This OID indicates that the current 24-hours Bytes counter is invalid
1.3.6.1.4.1.20044.47.11.2.272.1.3Columnpmc1008mpperfdatacomclientCurrent24StatInBytesCountPortnread-onlycurrentClient Current 24-hours Input Bytes counter :This OID gives the current 24-hours Bytes counter value
1.3.6.1.4.1.20044.47.11.2.272.1.4Columnpmc1008mpperfdatacomclientCurrent24StatInCrcCountInvPortnread-onlycurrentClient Current 24-hours Input CRC counter inv. :This OID indicates that the current 24-hours CRC counter is invalid
1.3.6.1.4.1.20044.47.11.2.272.1.5Columnpmc1008mpperfdatacomclientCurrent24StatInCrcCountPortnread-onlycurrentClient Current 24-hours Input CRC counter :This OID gives the current 24-hours CRC counter value
1.3.6.1.4.1.20044.47.11.2.272.1.8Columnpmc1008mpperfdatacomclientCurrent24StatInBroadcastCountInvPortnread-onlycurrentClient Current 24-hours Input Broadcast counter inv. :This OID indicates that the current 24-hours Broadcast counter is invalid
1.3.6.1.4.1.20044.47.11.2.272.1.9Columnpmc1008mpperfdatacomclientCurrent24StatInBroadcastCountPortnread-onlycurrentClient Current 24-hours Input Broadcast counter :This OID gives the current 24-hours Broadcast counter value
1.3.6.1.4.1.20044.47.11.2.272.1.10Columnpmc1008mpperfdatacomclientCurrent24StatInMulticastCountInvPortnread-onlycurrentClient Current 24-hours Input Multicast counter inv. :This OID indicates that the current 24-hours Multicast counter is invalid
1.3.6.1.4.1.20044.47.11.2.272.1.11Columnpmc1008mpperfdatacomclientCurrent24StatInMulticastCountPortnread-onlycurrentClient Current 24-hours Input Multicast counter :This OID gives the current 24-hours Multicast counter value
1.3.6.1.4.1.20044.47.11.2.272.1.20Columnpmc1008mpperfdatacomclientCurrent24StatInUnicastCountInvPortnread-onlycurrentClient Current 24-hours Input Unicast counter inv. :This OID indicates that the current 24-hours Unicast counter is invalid
1.3.6.1.4.1.20044.47.11.2.272.1.21Columnpmc1008mpperfdatacomclientCurrent24StatInUnicastCountPortnread-onlycurrentClient Current 24-hours Input Unicast counter :This OID gives the current 24-hours Unicast counter value
1.3.6.1.4.1.20044.47.11.2.272.1.22Columnpmc1008mpperfdatacomclientCurrent24StatInNonunicastCountInvPortnread-onlycurrentClient Current 24-hours Input Non Unicast counter inv. :This OID indicates that the current 24-hours Non unicast counter is invalid
1.3.6.1.4.1.20044.47.11.2.272.1.23Columnpmc1008mpperfdatacomclientCurrent24StatInNonunicastCountPortnread-onlycurrentClient Current 24-hours Input Non Unicast counter :This OID gives the current 24-hours Non Unicast counter value
1.3.6.1.4.1.20044.47.11.2.272.1.26Columnpmc1008mpperfdatacomclientCurrent24StatOutBytesCountInvPortnread-onlycurrentClient Current 24-hours Output Bytes counter inv. :This OID indicates that the current 24-hours Bytes counter is invalid
1.3.6.1.4.1.20044.47.11.2.272.1.27Columnpmc1008mpperfdatacomclientCurrent24StatOutBytesCountPortnread-onlycurrentClient Current 24-hours Output Bytes counter :This OID gives the current 24-hours Bytes counter value
1.3.6.1.4.1.20044.47.11.2.272.1.32Columnpmc1008mpperfdatacomclientCurrent24StatOutBroadcastCountInvPortnread-onlycurrentClient Current 24-hours Output Broadcast counter inv. :This OID indicates that the current 24-hours Broadcast counter is invalid
1.3.6.1.4.1.20044.47.11.2.272.1.33Columnpmc1008mpperfdatacomclientCurrent24StatOutBroadcastCountPortnread-onlycurrentClient Current 24-hours Output Broadcast counter :This OID gives the current 24-hours Broadcast counter value
1.3.6.1.4.1.20044.47.11.2.272.1.34Columnpmc1008mpperfdatacomclientCurrent24StatOutMulticastCountInvPortnread-onlycurrentClient Current 24-hours Output Multicast counter inv. :This OID indicates that the current 24-hours Multicast counter is invalid
1.3.6.1.4.1.20044.47.11.2.272.1.35Columnpmc1008mpperfdatacomclientCurrent24StatOutMulticastCountPortnread-onlycurrentClient Current 24-hours Output Multicast counter :This OID gives the current 24-hours Multicast counter value
1.3.6.1.4.1.20044.47.11.2.272.1.42Columnpmc1008mpperfdatacomclientCurrent24StatOutUnicastCountInvPortnread-onlycurrentClient Current 24-hours Output Unicast counter inv. :This OID indicates that the current 24-hours Unicast counter is invalid
1.3.6.1.4.1.20044.47.11.2.272.1.43Columnpmc1008mpperfdatacomclientCurrent24StatOutUnicastCountPortnread-onlycurrentClient Current 24-hours Output Unicast counter :This OID gives the current 24-hours Unicast counter value
1.3.6.1.4.1.20044.47.11.2.272.1.44Columnpmc1008mpperfdatacomclientCurrent24StatOutNonunicastCountInvPortnread-onlycurrentClient Current 24-hours Output Non Unicast counter inv. :This OID indicates that the current 24-hours Non Unicast counter is invalid
1.3.6.1.4.1.20044.47.11.2.272.1.45Columnpmc1008mpperfdatacomclientCurrent24StatOutNonunicastCountPortnread-onlycurrentClient Current 24-hours Output Non Unicast counter :This OID gives the current 24-hours Non Unicast counter value
1.3.6.1.4.1.20044.47.11.2.280Tablepmc1008mpPerfDatacomClientPast24StatHistoryPort1Tablenot-accessiblecurrentList of pmc1008mpPerfDatacomClientPast24StatHistory Article
1.3.6.1.4.1.20044.47.11.2.280.1Rowpmc1008mpPerfDatacomClientPast24StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pmc1008mpPerfDatacomClientPast24StatHistory table
1.3.6.1.4.1.20044.47.11.2.280.1.1Columnpmc1008mpPerfDatacomClientPast24StatHistoryPort1Indexread-onlycurrentIndex definition for the pmc1008mpPerfDatacomClientPast24StatHistory table
1.3.6.1.4.1.20044.47.11.2.280.1.2Columnpmc1008mpperfdatacomclientPast24StatInBytesCountInvPort1read-onlycurrentClient Past 24-hours Input Bytes counter inv. :This OID indicates that the past 24-hours Bytes counter is invalid
1.3.6.1.4.1.20044.47.11.2.280.1.3Columnpmc1008mpperfdatacomclientPast24StatInBytesCountPort1read-onlycurrentClient Past 24-hours Input Bytes counter :This OID gives the past 24-hours Bytes counter value
1.3.6.1.4.1.20044.47.11.2.280.1.4Columnpmc1008mpperfdatacomclientPast24StatInCrcCountInvPort1read-onlycurrentClient Past 24-hours Input CRC counter inv. :This OID indicates that the past 24-hours CRC counter is invalid
1.3.6.1.4.1.20044.47.11.2.280.1.5Columnpmc1008mpperfdatacomclientPast24StatInCrcCountPort1read-onlycurrentClient Past 24-hours Input CRC counter :This OID gives the past 24-hours CRC counter value
1.3.6.1.4.1.20044.47.11.2.280.1.8Columnpmc1008mpperfdatacomclientPast24StatInBroadcastCountInvPort1read-onlycurrentClient Past 24-hours Input Broadcast counter inv. :This OID indicates that the past 24-hours Broadcast counter is invalid
1.3.6.1.4.1.20044.47.11.2.280.1.9Columnpmc1008mpperfdatacomclientPast24StatInBroadcastCountPort1read-onlycurrentClient Past 24-hours Input Broadcast counter :This OID gives the past 24-hours Broadcast counter value
1.3.6.1.4.1.20044.47.11.2.280.1.10Columnpmc1008mpperfdatacomclientPast24StatInMulticastCountInvPort1read-onlycurrentClient Past 24-hours Input Multicast counter inv. :This OID indicates that the past 24-hours Multicast counter is invalid
1.3.6.1.4.1.20044.47.11.2.280.1.11Columnpmc1008mpperfdatacomclientPast24StatInMulticastCountPort1read-onlycurrentClient Past 24-hours Input Multicast counter :This OID gives the past 24-hours Multicast counter value
1.3.6.1.4.1.20044.47.11.2.280.1.20Columnpmc1008mpperfdatacomclientPast24StatInUnicastCountInvPort1read-onlycurrentClient Past 24-hours Input Unicast counter inv. :This OID indicates that the past 24-hours Unicast counter is invalid
1.3.6.1.4.1.20044.47.11.2.280.1.21Columnpmc1008mpperfdatacomclientPast24StatInUnicastCountPort1read-onlycurrentClient Past 24-hours Input Unicast counter :This OID gives the past 24-hours Unicast counter value
1.3.6.1.4.1.20044.47.11.2.280.1.22Columnpmc1008mpperfdatacomclientPast24StatInNonunicastCountInvPort1read-onlycurrentClient Past 24-hours Input Non Unicast counter inv. :This OID indicates that the past 24-hours Non unicast counter is invalid
1.3.6.1.4.1.20044.47.11.2.280.1.23Columnpmc1008mpperfdatacomclientPast24StatInNonunicastCountPort1read-onlycurrentClient Past 24-hours Input Non Unicast counter :This OID gives the past 24-hours Non Unicast counter value
1.3.6.1.4.1.20044.47.11.2.280.1.26Columnpmc1008mpperfdatacomclientPast24StatOutBytesCountInvPort1read-onlycurrentClient Past 24-hours Output Bytes counter inv. :This OID indicates that the past 24-hours Bytes counter is invalid
1.3.6.1.4.1.20044.47.11.2.280.1.27Columnpmc1008mpperfdatacomclientPast24StatOutBytesCountPort1read-onlycurrentClient Past 24-hours Output Bytes counter :This OID gives the past 24-hours Bytes counter value
1.3.6.1.4.1.20044.47.11.2.280.1.32Columnpmc1008mpperfdatacomclientPast24StatOutBroadcastCountInvPort1read-onlycurrentClient Past 24-hours Output Broadcast counter inv. :This OID indicates that the past 24-hours Broadcast counter is invalid
1.3.6.1.4.1.20044.47.11.2.280.1.33Columnpmc1008mpperfdatacomclientPast24StatOutBroadcastCountPort1read-onlycurrentClient Past 24-hours Output Broadcast counter :This OID gives the past 24-hours Broadcast counter value
1.3.6.1.4.1.20044.47.11.2.280.1.34Columnpmc1008mpperfdatacomclientPast24StatOutMulticastCountInvPort1read-onlycurrentClient Past 24-hours Output Multicast counter inv. :This OID indicates that the past 24-hours Multicast counter is invalid
1.3.6.1.4.1.20044.47.11.2.280.1.35Columnpmc1008mpperfdatacomclientPast24StatOutMulticastCountPort1read-onlycurrentClient Past 24-hours Output Multicast counter :This OID gives the past 24-hours Multicast counter value
1.3.6.1.4.1.20044.47.11.2.280.1.42Columnpmc1008mpperfdatacomclientPast24StatOutUnicastCountInvPort1read-onlycurrentClient Past 24-hours Output Unicast counter inv. :This OID indicates that the past 24-hours Unicast counter is invalid
1.3.6.1.4.1.20044.47.11.2.280.1.43Columnpmc1008mpperfdatacomclientPast24StatOutUnicastCountPort1read-onlycurrentClient Past 24-hours Output Unicast counter :This OID gives the past 24-hours Unicast counter value
1.3.6.1.4.1.20044.47.11.2.280.1.44Columnpmc1008mpperfdatacomclientPast24StatOutNonunicastCountInvPort1read-onlycurrentClient Past 24-hours Output Non Unicast counter inv. :This OID indicates that the past 24-hours Non Unicast counter is invalid
1.3.6.1.4.1.20044.47.11.2.280.1.45Columnpmc1008mpperfdatacomclientPast24StatOutNonunicastCountPort1read-onlycurrentClient Past 24-hours Output Non Unicast counter :This OID gives the past 24-hours Non Unicast counter value
1.3.6.1.4.1.20044.47.11.3Nodepmc1008mpMonLine
1.3.6.1.4.1.20044.47.11.3.128Tablepmc1008mpPerfTelecomLineCurrent15StatTablenot-accessiblecurrentList of pmc1008mpPerfTelecomLineCurrent15Stat Article
1.3.6.1.4.1.20044.47.11.3.128.1Rowpmc1008mpPerfTelecomLineCurrent15StatEntrynot-accessiblecurrentRow definition for the pmc1008mpPerfTelecomLineCurrent15Stat table
1.3.6.1.4.1.20044.47.11.3.128.1.1Columnpmc1008mpPerfTelecomLineCurrent15StatIndexread-onlycurrentIndex definition for the pmc1008mpPerfTelecomLineCurrent15Stat table
1.3.6.1.4.1.20044.47.11.3.128.1.2Columnpmc1008mpPerfTelecomLineCurrent15StatInvCvPortnread-onlycurrentCurrent 15-min CV counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.47.11.3.128.1.3Columnpmc1008mpPerfTelecomLineCurrent15StatCvValuePortnread-onlycurrentCurrent 15-min CV counter :This OID gives the current 15-min Coding Violation counter value
1.3.6.1.4.1.20044.47.11.3.128.1.4Columnpmc1008mpPerfTelecomLineCurrent15StatInvEsPortnread-onlycurrentCurrent 15-min ES counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.47.11.3.128.1.5Columnpmc1008mpPerfTelecomLineCurrent15StatEsValuePortnread-onlycurrentCurrent 15-min ES counter :This OID gives the current 15-min Errored Second counter value
1.3.6.1.4.1.20044.47.11.3.128.1.6Columnpmc1008mpPerfTelecomLineCurrent15StatInvSesPortnread-onlycurrentCurrent 15-min SES counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.47.11.3.128.1.7Columnpmc1008mpPerfTelecomLineCurrent15StatSesValuePortnread-onlycurrentCurrent 15-min SES counter :This OID gives the current 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.47.11.3.128.1.8Columnpmc1008mpPerfTelecomLineCurrent15StatInvSefsPortnread-onlycurrentCurrent 15-min SEFS counter inv. :This OID indicates that the current 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.47.11.3.128.1.9Columnpmc1008mpPerfTelecomLineCurrent15StatSefsValuePortnread-onlycurrentCurrent 15-min SEFS counter :This OID gives the current 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.47.11.3.128.1.10Columnpmc1008mpPerfTelecomLineCurrent15StatInvUasPortnread-onlycurrentCurrent 15-min UAS counter inv. :This OID indicates that the current 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.47.11.3.128.1.11Columnpmc1008mpPerfTelecomLineCurrent15StatUasValuePortnread-onlycurrentCurrent 15-min UAS counter :This OID gives the current 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.47.11.3.129Tablepmc1008mpPerfTelecomLinePast15StatHistoryPort1Tablenot-accessiblecurrentList of pmc1008mpPerfTelecomLinePast15StatHistory Article
1.3.6.1.4.1.20044.47.11.3.129.1Rowpmc1008mpPerfTelecomLinePast15StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pmc1008mpPerfTelecomLinePast15StatHistory table
1.3.6.1.4.1.20044.47.11.3.129.1.1Columnpmc1008mpPerfTelecomLinePast15StatHistoryPort1Indexread-onlycurrentIndex definition for the pmc1008mpPerfTelecomLinePast15StatHistory table
1.3.6.1.4.1.20044.47.11.3.129.1.2Columnpmc1008mpPerfTelecomLinePast15StatHistoryInvCvPort1read-onlycurrentPrevious 15-min CV counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.47.11.3.129.1.3Columnpmc1008mpPerfTelecomLinePast15StatHistoryCvValuePort1read-onlycurrentPrevious 15-min CV counter :This OID gives the previous 15-min Coding Violation counter value
1.3.6.1.4.1.20044.47.11.3.129.1.4Columnpmc1008mpPerfTelecomLinePast15StatHistoryInvEsPort1read-onlycurrentPrevious 15-min ES counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.47.11.3.129.1.5Columnpmc1008mpPerfTelecomLinePast15StatHistoryEsValuePort1read-onlycurrentPrevious 15-min ES counter :This OID gives the previous 15-min Errored Second counter value
1.3.6.1.4.1.20044.47.11.3.129.1.6Columnpmc1008mpPerfTelecomLinePast15StatHistoryInvSesPort1read-onlycurrentPrevious 15-min SES counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.47.11.3.129.1.7Columnpmc1008mpPerfTelecomLinePast15StatHistorySesValuePort1read-onlycurrentPrevious 15-min SES counter :This OID gives the previous 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.47.11.3.129.1.8Columnpmc1008mpPerfTelecomLinePast15StatHistoryInvSefsPort1read-onlycurrentPrevious 15-min SEFS counter inv. :This OID indicates that the previous 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.47.11.3.129.1.9Columnpmc1008mpPerfTelecomLinePast15StatHistorySefsValuePort1read-onlycurrentPrevious 15-min SEFS counter :This OID gives the previous 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.47.11.3.129.1.10Columnpmc1008mpPerfTelecomLinePast15StatHistoryInvUasPort1read-onlycurrentPrevious 15-min UAS counter inv. :This OID indicates that the previous 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.47.11.3.129.1.11Columnpmc1008mpPerfTelecomLinePast15StatHistoryUasValuePort1read-onlycurrentPrevious 15-min UAS counter :This OID gives the previous 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.47.11.3.130Tablepmc1008mpPerfTelecomLineCurrent24StatTablenot-accessiblecurrentList of pmc1008mpPerfTelecomLineCurrent24Stat Article
1.3.6.1.4.1.20044.47.11.3.130.1Rowpmc1008mpPerfTelecomLineCurrent24StatEntrynot-accessiblecurrentRow definition for the pmc1008mpPerfTelecomLineCurrent24Stat table
1.3.6.1.4.1.20044.47.11.3.130.1.1Columnpmc1008mpPerfTelecomLineCurrent24StatIndexread-onlycurrentIndex definition for the pmc1008mpPerfTelecomLineCurrent24Stat table
1.3.6.1.4.1.20044.47.11.3.130.1.2Columnpmc1008mpPerfTelecomLineCurrent24StatInvCvPortnread-onlycurrentCurrent 24-hours CV counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.47.11.3.130.1.3Columnpmc1008mpPerfTelecomLineCurrent24StatCvValuePortnread-onlycurrentCurrent 24-hours CV counter :This OID gives the current 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.47.11.3.130.1.4Columnpmc1008mpPerfTelecomLineCurrent24StatInvEsPortnread-onlycurrentCurrent 24-hours ES counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.47.11.3.130.1.5Columnpmc1008mpPerfTelecomLineCurrent24StatEsValuePortnread-onlycurrentCurrent 24-hours ES counter :This OID gives the current 24-hours Errored Second counter value
1.3.6.1.4.1.20044.47.11.3.130.1.6Columnpmc1008mpPerfTelecomLineCurrent24StatInvSesPortnread-onlycurrentCurrent 24-hours SES counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.47.11.3.130.1.7Columnpmc1008mpPerfTelecomLineCurrent24StatSesValuePortnread-onlycurrentCurrent 24-hours SES counter :This OID gives the current 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.47.11.3.130.1.8Columnpmc1008mpPerfTelecomLineCurrent24StatInvSefsPortnread-onlycurrentCurrent 24-hours SEFS counter inv. :This OID indicates that the current 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.47.11.3.130.1.9Columnpmc1008mpPerfTelecomLineCurrent24StatSefsValuePortnread-onlycurrentCurrent 24-hours SEFS counter :This OID gives the current 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.47.11.3.130.1.10Columnpmc1008mpPerfTelecomLineCurrent24StatInvUasPortnread-onlycurrentCurrent 24-hours UAS counter inv. :This OID indicates that the current 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.47.11.3.130.1.11Columnpmc1008mpPerfTelecomLineCurrent24StatUasValuePortnread-onlycurrentCurrent 24-hours UAS counter :This OID gives the current 24-hours UnAvailable Second counter value
1.3.6.1.4.1.20044.47.11.3.131Tablepmc1008mpPerfTelecomLinePast24StatHistoryPort1Tablenot-accessiblecurrentList of pmc1008mpPerfTelecomLinePast24StatHistory Article
1.3.6.1.4.1.20044.47.11.3.131.1Rowpmc1008mpPerfTelecomLinePast24StatHistoryPort1Entrynot-accessiblecurrentRow definition for the pmc1008mpPerfTelecomLinePast24StatHistory table
1.3.6.1.4.1.20044.47.11.3.131.1.1Columnpmc1008mpPerfTelecomLinePast24StatHistoryPort1Indexread-onlycurrentIndex definition for the pmc1008mpPerfTelecomLinePast24StatHistory table
1.3.6.1.4.1.20044.47.11.3.131.1.2Columnpmc1008mpPerfTelecomLinePast24StatHistoryInvCvPort1read-onlycurrentPrevious 24-hours CV counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.47.11.3.131.1.3Columnpmc1008mpPerfTelecomLinePast24StatHistoryCvValuePort1read-onlycurrentPrevious 24-hours CV counter :This OID gives the previous 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.47.11.3.131.1.4Columnpmc1008mpPerfTelecomLinePast24StatHistoryInvEsPort1read-onlycurrentPrevious 24-hours ES counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.47.11.3.131.1.5Columnpmc1008mpPerfTelecomLinePast24StatHistoryEsValuePort1read-onlycurrentPrevious 24-hours ES counter :This OID gives the previous 24-hours Errored Second counter value
1.3.6.1.4.1.20044.47.11.3.131.1.6Columnpmc1008mpPerfTelecomLinePast24StatHistoryInvSesPort1read-onlycurrentPrevious 24-hours SES counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.47.11.3.131.1.7Columnpmc1008mpPerfTelecomLinePast24StatHistorySesValuePort1read-onlycurrentPrevious 24-hours SES counter :This OID gives the previous 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.47.11.3.131.1.8Columnpmc1008mpPerfTelecomLinePast24StatHistoryInvSefsPort1read-onlycurrentPrevious 24-hours SEFS counter inv. :This OID indicates that the previous 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.47.11.3.131.1.9Columnpmc1008mpPerfTelecomLinePast24StatHistorySefsValuePort1read-onlycurrentPrevious 24-hours SEFS counter :This OID gives the previous 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.47.11.3.131.1.10Columnpmc1008mpPerfTelecomLinePast24StatHistoryInvUasPort1read-onlycurrentPrevious 24-hours UAS counter inv. :This OID indicates that the previous 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.47.11.3.131.1.11Columnpmc1008mpPerfTelecomLinePast24StatHistoryUasValuePort1read-onlycurrentPrevious 24-hours UAS counter :This OID gives the previous 24-hours UnAvailable Second counter value
Type Definitions
NameSyntaxStatusDescription
Pmc1008mpAdjustValueINTEGER { otxadjustvalue0(0), otxadjustvalue1(1), otxadjustvalue2(2), otxadjustvalue3(3), otxadjustvalue4(4), otxadjustvalue5(5), otxadjustvalue6(6), otxadjustvalue7(7), otxadjustvalue8(8), otxadjustvalue9(9), otxadjustvalue10(10) }currentDifferent values in Adjust mode on OTX-TLH on client and line ports
Pmc1008mpDccModeINTEGER { dccNo(0), dcctermLine1(1), dcctermLine2(2), dcctermLines12(3), dccmaster(4), dccslaveLine12(7) }currentMode for DCC
Pmc1008mpModeAddDropINTEGER { dualPassThrough(1), addDropTsA(2), addDropTsB(4), splitSelectTsA(8), splitSelectTsB(16), splitSelectTsATsB(32) }currentdifferent mode for client B
Pmc1008mpModeAddDropAINTEGER { passThroughA(1), addDropTsA(2), splitSelectTsA(4) }currentdifferent mode for client A
Pmc1008mpModeTimeSlotINTEGER { dualPassThrough(1), addDropTsA(2), addDropTsB(4), splitSelectTsA(8), splitSelectTsB(16), splitSelectTsATsB(32) }currentdifferent mode for time slot
Pmc1008mpOtxChannelINTEGERcurrentChannel selection on OTX-TLH on client and line ports
Pmc1008mpOtxGridINTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50) }currentDifferent grids on OTX-TLH on client and line ports
Pmc1008mpOtxModeINTEGER { otx80mode(1), otx60mode(2), otxadjustmode(4) }currentDifferent modes on OTX-TLH on client and line ports
Pmc1008mpProtectionStartUpINTEGER { auto(2), manualX2Line2(0), manualX1Line1(1) }currentprotection for startup
Pmc1008mpProtectionTimeSlotINTEGER { auto(0), manualX1Line1(257), manualX2Line2(513) }currentprotection for control