EKINOPS-Pme1008-MIB

482 objects
Creation.
OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.79IdentitymodulePme1008Creation.
1.3.6.1.4.1.20044.79.2Nodepme1008alarms
1.3.6.1.4.1.20044.79.2.1Nodepme1008AlmOther
1.3.6.1.4.1.20044.79.2.1.1Nodepme1008AlmOtherNurg
1.3.6.1.4.1.20044.79.2.1.1.2Nodepme1008AlmsynthAlm2
1.3.6.1.4.1.20044.79.2.1.1.2.1Scalarpme1008AlmConfTableSaveread-onlycurrentPM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> infor…
1.3.6.1.4.1.20044.79.2.1.1.2.2Scalarpme1008AlmInvUploadread-onlycurrentInventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> informationalStatus(1000) <Alarmtype> ot…
1.3.6.1.4.1.20044.79.2.1.1.2.3Scalarpme1008AlmConfTableLoadread-onlycurrentPM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> informationalStat…
1.3.6.1.4.1.20044.79.2.1.1.2.4Scalarpme1008AlmCorrelatOffread-onlycurrentNot Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> informationalStatus(1000) <Alarmtype…
1.3.6.1.4.1.20044.79.2.1.2Nodepme1008AlmOtherUrg
1.3.6.1.4.1.20044.79.2.1.3Nodepme1008AlmOtherCrit
1.3.6.1.4.1.20044.79.2.1.3.0Nodepme1008AlmsynthAlm0
1.3.6.1.4.1.20044.79.2.1.3.0.9Scalarpme1008AlmModGlobFailread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the RM <Help> This alarm is set on detection of a failure originating from the equip…
1.3.6.1.4.1.20044.79.2.1.3.0.15Scalarpme1008AlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.79.2.1.3.0.16Scalarpme1008AlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.79.2.2Nodepme1008AlmClient
1.3.6.1.4.1.20044.79.2.2.1Nodepme1008AlmClientNurg
1.3.6.1.4.1.20044.79.2.2.1.232Tablepme1008AlmclientSfpWarnDdmTablenot-accessiblecurrentList of pme1008AlmclientSfpWarnDdm Article
1.3.6.1.4.1.20044.79.2.2.1.232.1Rowpme1008AlmclientSfpWarnDdmEntrynot-accessiblecurrentRow definition for the pme1008AlmclientSfpWarnDdm table
1.3.6.1.4.1.20044.79.2.2.1.232.1.1Columnpme1008AlmclientSfpWarnDdmIndexread-onlycurrentIndex definition for the pme1008AlmclientSfpWarnDdm table
1.3.6.1.4.1.20044.79.2.2.1.232.1.2Columnpme1008AlmClientTxPwLowWngPortnread-onlycurrentClient Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.79.2.2.1.232.1.3Columnpme1008AlmClientTxPwrHighWngPortnread-onlycurrentClient Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.79.2.2.1.232.1.4Columnpme1008AlmClientTxBiasLowWngPortnread-onlycurrentClient Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.79.2.2.1.232.1.5Columnpme1008AlmClientTxBiasHighWngPortnread-onlycurrentClient Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warn…
1.3.6.1.4.1.20044.79.2.2.1.232.1.6Columnpme1008AlmClientVccLowWngPortnread-onlycurrentClient Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Warn…
1.3.6.1.4.1.20044.79.2.2.1.232.1.7Columnpme1008AlmClientVccHighWngPortnread-onlycurrentClient Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Wa…
1.3.6.1.4.1.20044.79.2.2.1.232.1.8Columnpme1008AlmClientTempLowWngPortnread-onlycurrentClient Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indic…
1.3.6.1.4.1.20044.79.2.2.1.232.1.9Columnpme1008AlmClientTempHighWngPortnread-onlycurrentClient Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning ind…
1.3.6.1.4.1.20044.79.2.2.1.232.1.16Columnpme1008AlmClientRxPwrLowWngPortnread-onlycurrentClient Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning i…
1.3.6.1.4.1.20044.79.2.2.1.232.1.17Columnpme1008AlmClientRxPwrHighWngPortnread-onlycurrentClient Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning…
1.3.6.1.4.1.20044.79.2.2.2Nodepme1008AlmClientUrg
1.3.6.1.4.1.20044.79.2.2.2.88Tablepme1008AlmclientHostLaneFaultTablenot-accessiblecurrentList of pme1008AlmclientHostLaneFault Article
1.3.6.1.4.1.20044.79.2.2.2.88.1Rowpme1008AlmclientHostLaneFaultEntrynot-accessiblecurrentRow definition for the pme1008AlmclientHostLaneFault table
1.3.6.1.4.1.20044.79.2.2.2.88.1.1Columnpme1008AlmclientHostLaneFaultIndexread-onlycurrentIndex definition for the pme1008AlmclientHostLaneFault table
1.3.6.1.4.1.20044.79.2.2.2.88.1.2Columnpme1008AlmClientLossOfSyncPortnread-onlycurrentClient Frame Alignment Loss :This OID indicates the module is not aligned with the incoming Client signal <Help> Alarm indicating the module is not aligned wit…
1.3.6.1.4.1.20044.79.2.2.2.88.1.3Columnpme1008AlmClientInputLossOfSigPortnread-onlycurrentClient Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Client Trscv <Help> Alarm indicating a Loss of Signal is detected on the Cl…
1.3.6.1.4.1.20044.79.2.2.2.88.1.7Columnpme1008AlmClientCsfDetectedPortnread-onlycurrentClient Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client…
1.3.6.1.4.1.20044.79.2.2.2.88.1.11Columnpme1008AlmClientLaneTxFifoErrorPortnread-onlycurrentClient Tx FIFO Error :This OID indicates a Tx FIFO Error on the Client Trscv <Help> Alarm indicating a Tx FIFO Error on the Client Trscv <Condtype> CLIENT_LANE…
1.3.6.1.4.1.20044.79.2.2.2.216Tablepme1008AlmclientSfpAlmDdmTablenot-accessiblecurrentList of pme1008AlmclientSfpAlmDdm Article
1.3.6.1.4.1.20044.79.2.2.2.216.1Rowpme1008AlmclientSfpAlmDdmEntrynot-accessiblecurrentRow definition for the pme1008AlmclientSfpAlmDdm table
1.3.6.1.4.1.20044.79.2.2.2.216.1.1Columnpme1008AlmclientSfpAlmDdmIndexread-onlycurrentIndex definition for the pme1008AlmclientSfpAlmDdm table
1.3.6.1.4.1.20044.79.2.2.2.216.1.2Columnpme1008AlmClientTxPwrLowAlaPortnread-onlycurrentClient Trscv Tx Power Low :This OID indicates that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in…
1.3.6.1.4.1.20044.79.2.2.2.216.1.3Columnpme1008AlmClientTxPwrHighAlaPortnread-onlycurrentClient Trscv Tx Power High :This OID indicates that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.79.2.2.2.216.1.4Columnpme1008AlmClientTxBiasLowAlaPortnread-onlycurrentClient Trscv Bias Low :This OID indicates that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.79.2.2.2.216.1.5Columnpme1008AlmClientTxBiasHighAlaPortnread-onlycurrentClient Trscv Bias High :This OID indicates that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM <Help> Alar…
1.3.6.1.4.1.20044.79.2.2.2.216.1.6Columnpme1008AlmClientVccLowAlaPortnread-onlycurrentClient Trscv Power Supply Low :This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM <Help> Alar…
1.3.6.1.4.1.20044.79.2.2.2.216.1.7Columnpme1008AlmClientVccHighAlaPortnread-onlycurrentClient Trscv Power Supply High :This OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM <Help> Al…
1.3.6.1.4.1.20044.79.2.2.2.216.1.8Columnpme1008AlmClientTempLowAlaPortnread-onlycurrentClient Trscv Temp Low :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicat…
1.3.6.1.4.1.20044.79.2.2.2.216.1.9Columnpme1008AlmClientTempHighAlaPortnread-onlycurrentClient Trscv Temp High :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indic…
1.3.6.1.4.1.20044.79.2.2.2.216.1.16Columnpme1008AlmClientRxPwrLowAlaPortnread-onlycurrentClient Trscv Rx Power Low :This OID indicates that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm ind…
1.3.6.1.4.1.20044.79.2.2.2.216.1.17Columnpme1008AlmClientRxPwrHighAlaPortnread-onlycurrentClient Trscv Rx Power High :This OID indicates that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm i…
1.3.6.1.4.1.20044.79.2.2.3Nodepme1008AlmClientCrit
1.3.6.1.4.1.20044.79.2.2.3.8Tablepme1008AlmsynthAlmPortTablenot-accessiblecurrentList of pme1008AlmsynthAlmPort Article
1.3.6.1.4.1.20044.79.2.2.3.8.1Rowpme1008AlmsynthAlmPortEntrynot-accessiblecurrentRow definition for the pme1008AlmsynthAlmPort table
1.3.6.1.4.1.20044.79.2.2.3.8.1.1Columnpme1008AlmsynthAlmPortIndexread-onlycurrentIndex definition for the pme1008AlmsynthAlmPort table
1.3.6.1.4.1.20044.79.2.2.3.8.1.2Columnpme1008AlmSfpAbsentPortnread-onlycurrentClient SFP Absent :This OID indicates that the Transceiver is not present in the client port. <Help> This alarm indicates if the client transceiver is not plug…
1.3.6.1.4.1.20044.79.2.2.3.8.1.3Columnpme1008AlmDdmAbsentPortnread-onlycurrentDDM Supported On Client Trscv :This OID indicates that the Client transceiver supports the Digital Diagnostic Monitoring function <Help> This status indicates …
1.3.6.1.4.1.20044.79.2.2.3.8.1.5Columnpme1008AlmHwFailAccPortnread-onlycurrentClient HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Help> This alarm indicates a failure on client port, most pro…
1.3.6.1.4.1.20044.79.2.2.3.8.1.6Columnpme1008AlmDwLsdPortnread-onlycurrentClient SFP Laser Shutdown :This OID indicates the Client transceiver laser is shutdown <Help> This status indicates if the client transceiver laser is shutdown…
1.3.6.1.4.1.20044.79.2.2.3.8.1.7Columnpme1008AlmClientLocalOosPortnread-onlycurrentLocal Client Port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local c…
1.3.6.1.4.1.20044.79.2.2.3.8.1.8Columnpme1008AlmClientRemoteOosPortnread-onlycurrentRemote Client Port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the remot…
1.3.6.1.4.1.20044.79.2.2.3.8.1.9Columnpme1008AlmDwCaisPortnread-onlycurrentClient AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indicates if a Client Alarm Indication Signal is…
1.3.6.1.4.1.20044.79.2.2.3.8.1.10Columnpme1008AlmSfpDdmWarningPortnread-onlycurrentWarning On Client Trscv DDM :This OID indicates a warning is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Warning has be…
1.3.6.1.4.1.20044.79.2.2.3.8.1.11Columnpme1008AlmSfpDdmAlmPortnread-onlycurrentAlarm On Client Trscv DDM :This OID indicates an alarm is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Alarm has been de…
1.3.6.1.4.1.20044.79.2.2.3.8.1.13Columnpme1008AlmFailAccPortnread-onlycurrentClient Access Fail :This OID indicates a failure on the Client port <Help> This alarm indicates a failure on the Client port <Condtype> FAIL_ACC_1 <Probcause> …
1.3.6.1.4.1.20044.79.2.2.3.8.1.17Columnpme1008AlmUpCsfPortnread-onlycurrentClient Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu…
1.3.6.1.4.1.20044.79.2.3Nodepme1008AlmLine
1.3.6.1.4.1.20044.79.2.3.1Nodepme1008AlmLineNurg
1.3.6.1.4.1.20044.79.2.3.2Nodepme1008AlmLineUrg
1.3.6.1.4.1.20044.79.2.3.2.104Tablepme1008AlmlineNetworkLaneAlarmWarning1Tablenot-accessiblecurrentList of pme1008AlmlineNetworkLaneAlarmWarning1 Article
1.3.6.1.4.1.20044.79.2.3.2.104.1Rowpme1008AlmlineNetworkLaneAlarmWarning1Entrynot-accessiblecurrentRow definition for the pme1008AlmlineNetworkLaneAlarmWarning1 table
1.3.6.1.4.1.20044.79.2.3.2.104.1.1Columnpme1008AlmlineNetworkLaneAlarmWarning1Indexread-onlycurrentIndex definition for the pme1008AlmlineNetworkLaneAlarmWarning1 table
1.3.6.1.4.1.20044.79.2.3.2.104.1.2Columnpme1008AlmLineTxPwrLowAlaPortnread-onlycurrentLine Trscv Tx Power Low :This OID indicates that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indi…
1.3.6.1.4.1.20044.79.2.3.2.104.1.3Columnpme1008AlmLineTxPwrHighAlaPortnread-onlycurrentLine Trscv Tx Power High :This OID indicates that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm in…
1.3.6.1.4.1.20044.79.2.3.2.104.1.4Columnpme1008AlmLineTxBiasLowAlaPortnread-onlycurrentLine Trscv Bias Low :This OID indicates that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in…
1.3.6.1.4.1.20044.79.2.3.2.104.1.5Columnpme1008AlmLineTxBiasHighAlaPortnread-onlycurrentLine Trscv Bias High :This OID indicates that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.79.2.3.2.104.1.6Columnpme1008AlmLineVccLowAlaPortnread-onlycurrentLine Trscv Power Supply Low :This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.79.2.3.2.104.1.7Columnpme1008AlmLineVccHighAlaPortnread-onlycurrentLine Trscv Power Supply High :This OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM <Help> Alar…
1.3.6.1.4.1.20044.79.2.3.2.104.1.8Columnpme1008AlmLineTempLowAlaPortnread-onlycurrentLine Trscv Temp Low :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicatin…
1.3.6.1.4.1.20044.79.2.3.2.104.1.9Columnpme1008AlmLineTempHighAlaPortnread-onlycurrentLine Trscv Temp High :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indicat…
1.3.6.1.4.1.20044.79.2.3.2.104.1.16Columnpme1008AlmLineRxPwrLowAlaPortnread-onlycurrentLine Trscv Rx Power Low :This OID indicates that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indic…
1.3.6.1.4.1.20044.79.2.3.2.104.1.17Columnpme1008AlmLineRxPwrHighAlaPortnread-onlycurrentLine Trscv Rx Power High :This OID indicates that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm ind…
1.3.6.1.4.1.20044.79.2.3.2.120Tablepme1008AlmlineNetworkLaneAlarmWarning2Tablenot-accessiblecurrentList of pme1008AlmlineNetworkLaneAlarmWarning2 Article
1.3.6.1.4.1.20044.79.2.3.2.120.1Rowpme1008AlmlineNetworkLaneAlarmWarning2Entrynot-accessiblecurrentRow definition for the pme1008AlmlineNetworkLaneAlarmWarning2 table
1.3.6.1.4.1.20044.79.2.3.2.120.1.1Columnpme1008AlmlineNetworkLaneAlarmWarning2Indexread-onlycurrentIndex definition for the pme1008AlmlineNetworkLaneAlarmWarning2 table
1.3.6.1.4.1.20044.79.2.3.2.120.1.2Columnpme1008AlmLineTxPwLowWngPortnread-onlycurrentLine Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning in…
1.3.6.1.4.1.20044.79.2.3.2.120.1.3Columnpme1008AlmLineTxPwrHighWngPortnread-onlycurrentLine Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.79.2.3.2.120.1.4Columnpme1008AlmLineTxBiasLowWngPortnread-onlycurrentLine Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.79.2.3.2.120.1.5Columnpme1008AlmLineTxBiasHighWngPortnread-onlycurrentLine Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.79.2.3.2.120.1.6Columnpme1008AlmLineVccLowWngPortnread-onlycurrentLine Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.79.2.3.2.120.1.7Columnpme1008AlmLineVccHighWngPortnread-onlycurrentLine Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Warn…
1.3.6.1.4.1.20044.79.2.3.2.120.1.8Columnpme1008AlmLineTempLowWngPortnread-onlycurrentLine Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indicat…
1.3.6.1.4.1.20044.79.2.3.2.120.1.9Columnpme1008AlmLineTempHighWngPortnread-onlycurrentLine Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning indic…
1.3.6.1.4.1.20044.79.2.3.2.120.1.16Columnpme1008AlmLineRxPwrLowWngPortnread-onlycurrentLine Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning ind…
1.3.6.1.4.1.20044.79.2.3.2.120.1.17Columnpme1008AlmLineRxPwrHighWngPortnread-onlycurrentLine Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning i…
1.3.6.1.4.1.20044.79.2.3.2.152Tablepme1008AlmlineHostLaneFaultTablenot-accessiblecurrentList of pme1008AlmlineHostLaneFault Article
1.3.6.1.4.1.20044.79.2.3.2.152.1Rowpme1008AlmlineHostLaneFaultEntrynot-accessiblecurrentRow definition for the pme1008AlmlineHostLaneFault table
1.3.6.1.4.1.20044.79.2.3.2.152.1.1Columnpme1008AlmlineHostLaneFaultIndexread-onlycurrentIndex definition for the pme1008AlmlineHostLaneFault table
1.3.6.1.4.1.20044.79.2.3.2.152.1.2Columnpme1008AlmLineInputLossOfSignalPortnread-onlycurrentLine Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Line Trscv<Help> This alarm indicates if an Optical Path Break has been detec…
1.3.6.1.4.1.20044.79.2.3.2.152.1.3Columnpme1008AlmLineLossOfFramePortnread-onlycurrentLine Loss Of Frame :This OID indicates the module is not aligned with the incoming Line signal<Help> This alarm indicates if a Loss Of Frame has been detected …
1.3.6.1.4.1.20044.79.2.3.3Nodepme1008AlmLineCrit
1.3.6.1.4.1.20044.79.2.3.3.24Tablepme1008AlmsynthAlmLineTablenot-accessiblecurrentList of pme1008AlmsynthAlmLine Article
1.3.6.1.4.1.20044.79.2.3.3.24.1Rowpme1008AlmsynthAlmLineEntrynot-accessiblecurrentRow definition for the pme1008AlmsynthAlmLine table
1.3.6.1.4.1.20044.79.2.3.3.24.1.1Columnpme1008AlmsynthAlmLineIndexread-onlycurrentIndex definition for the pme1008AlmsynthAlmLine table
1.3.6.1.4.1.20044.79.2.3.3.24.1.2Columnpme1008AlmLineSfpAbsentPortnread-onlycurrentLine Optical Module Absent :This OID indicates that the line optical interface is not present. <Help> This alarm indicates if the line transceiver is not plugg…
1.3.6.1.4.1.20044.79.2.3.3.24.1.3Columnpme1008AlmLineDdmAbsentPortnread-onlycurrentLine Optical Module Ready :This OID indicates that the optical interface is not operational. <Help> This status indicates if the line transceiver has been corr…
1.3.6.1.4.1.20044.79.2.3.3.24.1.5Columnpme1008AlmLineHwFailPortnread-onlycurrentLine Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Help> This alarm indicates a failure on line port, most pr…
1.3.6.1.4.1.20044.79.2.3.3.24.1.6Columnpme1008AlmLineTxOffPortnread-onlycurrentLine Optical Module Laser Shutdown :This OID indicates the Line transceiver laser is shutdown <Help> This status indicates if the Line transceiver laser is shu…
1.3.6.1.4.1.20044.79.2.3.3.24.1.7Columnpme1008AlmLineLocalOosPortnread-onlycurrentLine Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service…
1.3.6.1.4.1.20044.79.2.3.3.24.1.9Columnpme1008AlmUpRdiInsPortnread-onlycurrentMS-RDI/L-RDI Inserted On Line :This OID indicates an upstream MS-RDI/L-RDI has been inserted in the outgoing 10 Gb/s SDH/SONET signal. <Help> This status indic…
1.3.6.1.4.1.20044.79.2.3.3.24.1.10Columnpme1008AlmLineDdmWarningPortnread-onlycurrentWarning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Warning has…
1.3.6.1.4.1.20044.79.2.3.3.24.1.11Columnpme1008AlmLineDdmAlmPortnread-onlycurrentAlarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Alarm has been…
1.3.6.1.4.1.20044.79.2.3.3.24.1.13Columnpme1008AlmLineFailPortnread-onlycurrentLine Port Failure :This OID indicates a failure on the line port <Help> This alarm indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipm…
1.3.6.1.4.1.20044.79.3Nodepme1008measures
1.3.6.1.4.1.20044.79.3.1Nodepme1008MesrOther
1.3.6.1.4.1.20044.79.3.2Nodepme1008MesrClient
1.3.6.1.4.1.20044.79.3.2.16Tablepme1008MesrclientTempTablenot-accessiblecurrentList of pme1008MesrclientTemp Article
1.3.6.1.4.1.20044.79.3.2.16.1Rowpme1008MesrclientTempEntrynot-accessiblecurrentRow definition for the pme1008MesrclientTemp table
1.3.6.1.4.1.20044.79.3.2.16.1.1Columnpme1008MesrclientTempIndexread-onlycurrentIndex definition for the pme1008MesrclientTemp table
1.3.6.1.4.1.20044.79.3.2.16.1.2Columnpme1008MesrclientTempPortnread-onlycurrentClient SFP Temperature :This OID gives the Laser temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = …
1.3.6.1.4.1.20044.79.3.2.32Tablepme1008MesrclientTxBiasTablenot-accessiblecurrentList of pme1008MesrclientTxBias Article
1.3.6.1.4.1.20044.79.3.2.32.1Rowpme1008MesrclientTxBiasEntrynot-accessiblecurrentRow definition for the pme1008MesrclientTxBias table
1.3.6.1.4.1.20044.79.3.2.32.1.1Columnpme1008MesrclientTxBiasIndexread-onlycurrentIndex definition for the pme1008MesrclientTxBias table
1.3.6.1.4.1.20044.79.3.2.32.1.2Columnpme1008MesrclientTxBiasPortnread-onlycurrentClient SFP Laser Bias :This OID gives the Laser bias value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit =…
1.3.6.1.4.1.20044.79.3.2.48Tablepme1008MesrclientTxPwrTablenot-accessiblecurrentList of pme1008MesrclientTxPwr Article
1.3.6.1.4.1.20044.79.3.2.48.1Rowpme1008MesrclientTxPwrEntrynot-accessiblecurrentRow definition for the pme1008MesrclientTxPwr table
1.3.6.1.4.1.20044.79.3.2.48.1.1Columnpme1008MesrclientTxPwrIndexread-onlycurrentIndex definition for the pme1008MesrclientTxPwr table
1.3.6.1.4.1.20044.79.3.2.48.1.2Columnpme1008MesrclientTxPwrPortnread-onlycurrentClient SFP Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-4…
1.3.6.1.4.1.20044.79.3.2.64Tablepme1008MesrclientRxPwrTablenot-accessiblecurrentList of pme1008MesrclientRxPwr Article
1.3.6.1.4.1.20044.79.3.2.64.1Rowpme1008MesrclientRxPwrEntrynot-accessiblecurrentRow definition for the pme1008MesrclientRxPwr table
1.3.6.1.4.1.20044.79.3.2.64.1.1Columnpme1008MesrclientRxPwrIndexread-onlycurrentIndex definition for the pme1008MesrclientRxPwr table
1.3.6.1.4.1.20044.79.3.2.64.1.2Columnpme1008MesrclientRxPwrPortnread-onlycurrentClient SFP Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) …
1.3.6.1.4.1.20044.79.3.3Nodepme1008MesrLine
1.3.6.1.4.1.20044.79.3.3.80Tablepme1008MesrlineTxPwrTablenot-accessiblecurrentList of pme1008MesrlineTxPwr Article
1.3.6.1.4.1.20044.79.3.3.80.1Rowpme1008MesrlineTxPwrEntrynot-accessiblecurrentRow definition for the pme1008MesrlineTxPwr table
1.3.6.1.4.1.20044.79.3.3.80.1.1Columnpme1008MesrlineTxPwrIndexread-onlycurrentIndex definition for the pme1008MesrlineTxPwr table
1.3.6.1.4.1.20044.79.3.3.80.1.2Columnpme1008MesrlineTxPwrPortnread-onlycurrentLine Optical Module Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power …
1.3.6.1.4.1.20044.79.3.3.96Tablepme1008MesrlineTempTablenot-accessiblecurrentList of pme1008MesrlineTemp Article
1.3.6.1.4.1.20044.79.3.3.96.1Rowpme1008MesrlineTempEntrynot-accessiblecurrentRow definition for the pme1008MesrlineTemp table
1.3.6.1.4.1.20044.79.3.3.96.1.1Columnpme1008MesrlineTempIndexread-onlycurrentIndex definition for the pme1008MesrlineTemp table
1.3.6.1.4.1.20044.79.3.3.96.1.2Columnpme1008MesrlineTempPortnread-onlycurrentLine Optical Module Temperature :This OID gives the Tx Laser Temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temp…
1.3.6.1.4.1.20044.79.3.3.112Tablepme1008MesrlineTxBiasTablenot-accessiblecurrentList of pme1008MesrlineTxBias Article
1.3.6.1.4.1.20044.79.3.3.112.1Rowpme1008MesrlineTxBiasEntrynot-accessiblecurrentRow definition for the pme1008MesrlineTxBias table
1.3.6.1.4.1.20044.79.3.3.112.1.1Columnpme1008MesrlineTxBiasIndexread-onlycurrentIndex definition for the pme1008MesrlineTxBias table
1.3.6.1.4.1.20044.79.3.3.112.1.2Columnpme1008MesrlineTxBiasPortnread-onlycurrentLine Optical Module Laser Bias :This OID gives the Tx Laser Bias value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/50…
1.3.6.1.4.1.20044.79.3.3.128Tablepme1008MesrlineRxPwrTablenot-accessiblecurrentList of pme1008MesrlineRxPwr Article
1.3.6.1.4.1.20044.79.3.3.128.1Rowpme1008MesrlineRxPwrEntrynot-accessiblecurrentRow definition for the pme1008MesrlineRxPwr table
1.3.6.1.4.1.20044.79.3.3.128.1.1Columnpme1008MesrlineRxPwrIndexread-onlycurrentIndex definition for the pme1008MesrlineRxPwr table
1.3.6.1.4.1.20044.79.3.3.128.1.2Columnpme1008MesrlineRxPwrPortnread-onlycurrentLine Optical Module Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(A…
1.3.6.1.4.1.20044.79.4Nodepme1008counters
1.3.6.1.4.1.20044.79.4.1Nodepme1008CntOther
1.3.6.1.4.1.20044.79.4.2Nodepme1008CntClient
1.3.6.1.4.1.20044.79.4.2.96Tablepme1008CntclientCbipCounterTablenot-accessiblecurrentList of pme1008CntclientCbipCounter Article
1.3.6.1.4.1.20044.79.4.2.96.1Rowpme1008CntclientCbipCounterEntrynot-accessiblecurrentRow definition for the pme1008CntclientCbipCounter table
1.3.6.1.4.1.20044.79.4.2.96.1.1Columnpme1008CntclientCbipCounterIndexread-onlycurrentIndex definition for the pme1008CntclientCbipCounter table
1.3.6.1.4.1.20044.79.4.2.96.1.2Columnpme1008CntclientCbipCounterValuePortnread-onlycurrentClient Output Errors :This counter is incremented each time a BIP error is detected on the Client path <Help> This counter gives the number of CBIP errors on t…
1.3.6.1.4.1.20044.79.4.2.96.1.3Columnpme1008CntclientCbipCounterErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the CBIP error counter value is invalid on Port
1.3.6.1.4.1.20044.79.4.2.96.1.4Columnpme1008CntclientCbipCounterOverloadPortnread-onlycurrentClient CBIP Counter Overload :This OID when set indicates a CBIP error counter overload on Port
1.3.6.1.4.1.20044.79.4.3Nodepme1008CntLine
1.3.6.1.4.1.20044.79.4.3.192Tablepme1008CntlocalLineSmBip8ErrorCounterTablenot-accessiblecurrentList of pme1008CntlocalLineSmBip8ErrorCounter Article
1.3.6.1.4.1.20044.79.4.3.192.1Rowpme1008CntlocalLineSmBip8ErrorCounterEntrynot-accessiblecurrentRow definition for the pme1008CntlocalLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.79.4.3.192.1.1Columnpme1008CntlocalLineSmBip8ErrorCounterIndexread-onlycurrentIndex definition for the pme1008CntlocalLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.79.4.3.192.1.2Columnpme1008CntlocalLineSmBip8ErrorCounterValuePortnread-onlycurrentLine Input FCS Errors :This counter is increased each time a FCS error is detected on the line input stream <Help> This counter gives the number of FCS errors …
1.3.6.1.4.1.20044.79.4.3.192.1.3Columnpme1008CntlocalLineSmBip8ErrorCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the B1 error counter value is invalid on Port
1.3.6.1.4.1.20044.79.4.3.192.1.4Columnpme1008CntlocalLineSmBip8ErrorCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a B1 error counter overload on Port
1.3.6.1.4.1.20044.79.4.3.216Tablepme1008CntlineDfrmTimCntTablenot-accessiblecurrentList of pme1008CntlineDfrmTimCnt Article
1.3.6.1.4.1.20044.79.4.3.216.1Rowpme1008CntlineDfrmTimCntEntrynot-accessiblecurrentRow definition for the pme1008CntlineDfrmTimCnt table
1.3.6.1.4.1.20044.79.4.3.216.1.1Columnpme1008CntlineDfrmTimCntIndexread-onlycurrentIndex definition for the pme1008CntlineDfrmTimCnt table
1.3.6.1.4.1.20044.79.4.3.216.1.2Columnpme1008CntlineDfrmTimCntValuePortnread-onlycurrentLine Timer Counter :
1.3.6.1.4.1.20044.79.4.3.216.1.3Columnpme1008CntlineDfrmTimCntErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.79.4.3.216.1.4Columnpme1008CntlineDfrmTimCntOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.79.4.259Scalarpme1008CntCountersResetread-writecurrentCounters Reset:This OID resets and restarts all the counters
1.3.6.1.4.1.20044.79.4.260Scalarpme1008CntCountersStopread-writecurrentCounters stop:This OID stops all the counters
1.3.6.1.4.1.20044.79.6Nodepme1008controlsWrite
1.3.6.1.4.1.20044.79.6.1Nodepme1008CtrlOther
1.3.6.1.4.1.20044.79.6.1.1Nodepme1008CtrlconfMgnt1
1.3.6.1.4.1.20044.79.6.1.1.1Scalarpme1008CtrlConf1Load1read-writecurrentLoad Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM.
1.3.6.1.4.1.20044.79.6.1.1.2Scalarpme1008CtrlConf2Load1read-writecurrentLoad Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM.
1.3.6.1.4.1.20044.79.6.1.1.10Scalarpme1008CtrlConf2Flash1read-writecurrentWrite Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura…
1.3.6.1.4.1.20044.79.6.1.1.14Scalarpme1008CtrlConf2Clear1read-writecurrentClear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o…
1.3.6.1.4.1.20044.79.6.1.4Nodepme1008Ctrlsynth4
1.3.6.1.4.1.20044.79.6.1.4.1Scalarpme1008CtrlCorrelatOnread-writecurrentEnable Alarm Correlation :This OID enables the alarm correlation in the PM.
1.3.6.1.4.1.20044.79.6.1.4.2Scalarpme1008CtrlCorrelatOffread-writecurrentDisable Alarm Correlation :This OID disables the alarm correlation in the PM.
1.3.6.1.4.1.20044.79.6.1.5Nodepme1008CtrlswMgnt
1.3.6.1.4.1.20044.79.6.1.5.2Scalarpme1008CtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> …
1.3.6.1.4.1.20044.79.6.1.5.3Scalarpme1008CtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th…
1.3.6.1.4.1.20044.79.6.1.5.5Scalarpme1008CtrlLoadSwBank1read-writecurrentSet Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW…
1.3.6.1.4.1.20044.79.6.1.5.6Scalarpme1008CtrlLoadSwBank2read-writecurrentSet Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S…
1.3.6.1.4.1.20044.79.6.1.6Nodepme1008CtrlgwMgnt
1.3.6.1.4.1.20044.79.6.1.6.1Scalarpme1008CtrlCurrentGwResetread-writecurrentActive Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting.
1.3.6.1.4.1.20044.79.6.1.6.5Scalarpme1008CtrlLoadGwBank1read-writecurrentSet Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.79.6.1.6.6Scalarpme1008CtrlLoadGwBank2read-writecurrentSet Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.79.6.1.6.7Scalarpme1008CtrlLoadGwBank3read-writecurrentSet Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.79.6.1.6.8Scalarpme1008CtrlLoadGwBank4read-writecurrentSet Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.79.6.1.192Nodepme1008CtrlledTest
1.3.6.1.4.1.20044.79.6.1.192.1Scalarpme1008CtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.79.6.1.192.2Scalarpme1008CtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.79.6.1.192.3Scalarpme1008CtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.79.6.2Nodepme1008CtrlClient
1.3.6.1.4.1.20044.79.6.2.16Tablepme1008CtrlaccessLoopTablenot-accessiblecurrentList of pme1008CtrlaccessLoop Article
1.3.6.1.4.1.20044.79.6.2.16.1Rowpme1008CtrlaccessLoopEntrynot-accessiblecurrentRow definition for the pme1008CtrlaccessLoop table
1.3.6.1.4.1.20044.79.6.2.16.1.1Columnpme1008CtrlaccessLoopIndexread-onlycurrentIndex definition for the pme1008CtrlaccessLoop table
1.3.6.1.4.1.20044.79.6.2.16.1.2Columnpme1008CtrlaccessLoopPortnread-writecurrentClient Facility Loopback :This OID, when set at '1' puts the client port in loopback, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. <Help…
1.3.6.1.4.1.20044.79.6.2.17Tablepme1008CtrlclientLoopToLineTablenot-accessiblecurrentList of pme1008CtrlclientLoopToLine Article
1.3.6.1.4.1.20044.79.6.2.17.1Rowpme1008CtrlclientLoopToLineEntrynot-accessiblecurrentRow definition for the pme1008CtrlclientLoopToLine table
1.3.6.1.4.1.20044.79.6.2.17.1.1Columnpme1008CtrlclientLoopToLineIndexread-onlycurrentIndex definition for the pme1008CtrlclientLoopToLine table
1.3.6.1.4.1.20044.79.6.2.17.1.2Columnpme1008CtrlclientLoopToLinePortnread-writecurrentClient Terminal Loopback :This OID, when set, puts the client port in loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.<Help> This control ena…
1.3.6.1.4.1.20044.79.6.2.21Tablepme1008CtrlcsfUpInsTablenot-accessiblecurrentList of pme1008CtrlcsfUpIns Article
1.3.6.1.4.1.20044.79.6.2.21.1Rowpme1008CtrlcsfUpInsEntrynot-accessiblecurrentRow definition for the pme1008CtrlcsfUpIns table
1.3.6.1.4.1.20044.79.6.2.21.1.1Columnpme1008CtrlcsfUpInsIndexread-onlycurrentIndex definition for the pme1008CtrlcsfUpIns table
1.3.6.1.4.1.20044.79.6.2.21.1.2Columnpme1008CtrlcsfUpInsPortnread-writecurrentClient Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo…
1.3.6.1.4.1.20044.79.6.2.22Tablepme1008CtrlcaisDwInsTablenot-accessiblecurrentList of pme1008CtrlcaisDwIns Article
1.3.6.1.4.1.20044.79.6.2.22.1Rowpme1008CtrlcaisDwInsEntrynot-accessiblecurrentRow definition for the pme1008CtrlcaisDwIns table
1.3.6.1.4.1.20044.79.6.2.22.1.1Columnpme1008CtrlcaisDwInsIndexread-onlycurrentIndex definition for the pme1008CtrlcaisDwIns table
1.3.6.1.4.1.20044.79.6.2.22.1.2Columnpme1008CtrlcaisDwInsPortnread-writecurrentClient AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port
1.3.6.1.4.1.20044.79.6.2.23Tablepme1008CtrlclientOciTablenot-accessiblecurrentList of pme1008CtrlclientOci Article
1.3.6.1.4.1.20044.79.6.2.23.1Rowpme1008CtrlclientOciEntrynot-accessiblecurrentRow definition for the pme1008CtrlclientOci table
1.3.6.1.4.1.20044.79.6.2.23.1.1Columnpme1008CtrlclientOciIndexread-onlycurrentIndex definition for the pme1008CtrlclientOci table
1.3.6.1.4.1.20044.79.6.2.23.1.2Columnpme1008CtrlclientOciPortnread-writecurrentODU2e-OCI :Label <Help> This control inserts a Client OCI
1.3.6.1.4.1.20044.79.6.2.24Tablepme1008CtrlclientLckTablenot-accessiblecurrentList of pme1008CtrlclientLck Article
1.3.6.1.4.1.20044.79.6.2.24.1Rowpme1008CtrlclientLckEntrynot-accessiblecurrentRow definition for the pme1008CtrlclientLck table
1.3.6.1.4.1.20044.79.6.2.24.1.1Columnpme1008CtrlclientLckIndexread-onlycurrentIndex definition for the pme1008CtrlclientLck table
1.3.6.1.4.1.20044.79.6.2.24.1.2Columnpme1008CtrlclientLckPortnread-writecurrentODU2e-LCK :Label <Help> This control inserts a Client LCK
1.3.6.1.4.1.20044.79.6.2.25Tablepme1008CtrlclientAisTablenot-accessiblecurrentList of pme1008CtrlclientAis Article
1.3.6.1.4.1.20044.79.6.2.25.1Rowpme1008CtrlclientAisEntrynot-accessiblecurrentRow definition for the pme1008CtrlclientAis table
1.3.6.1.4.1.20044.79.6.2.25.1.1Columnpme1008CtrlclientAisIndexread-onlycurrentIndex definition for the pme1008CtrlclientAis table
1.3.6.1.4.1.20044.79.6.2.25.1.2Columnpme1008CtrlclientAisPortnread-writecurrentODU2e-AIS :Label <Help> This control inserts a Client AIS
1.3.6.1.4.1.20044.79.6.2.26Tablepme1008CtrlclientBdiTablenot-accessiblecurrentList of pme1008CtrlclientBdi Article
1.3.6.1.4.1.20044.79.6.2.26.1Rowpme1008CtrlclientBdiEntrynot-accessiblecurrentRow definition for the pme1008CtrlclientBdi table
1.3.6.1.4.1.20044.79.6.2.26.1.1Columnpme1008CtrlclientBdiIndexread-onlycurrentIndex definition for the pme1008CtrlclientBdi table
1.3.6.1.4.1.20044.79.6.2.26.1.2Columnpme1008CtrlclientBdiPortnread-writecurrentODU2e-BDI :Label <Help> This control inserts a Client BDI
1.3.6.1.4.1.20044.79.6.3Nodepme1008CtrlLine
1.3.6.1.4.1.20044.79.6.3.64Tablepme1008CtrlcommAccessLoopTablenot-accessiblecurrentList of pme1008CtrlcommAccessLoop Article
1.3.6.1.4.1.20044.79.6.3.64.1Rowpme1008CtrlcommAccessLoopEntrynot-accessiblecurrentRow definition for the pme1008CtrlcommAccessLoop table
1.3.6.1.4.1.20044.79.6.3.64.1.1Columnpme1008CtrlcommAccessLoopIndexread-onlycurrentIndex definition for the pme1008CtrlcommAccessLoop table
1.3.6.1.4.1.20044.79.6.3.64.1.2Columnpme1008CtrlcommAccessLoopPortnread-writecurrentLine Terminal Loopback :This OID, when set, puts the module in common access loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.<Help> This cont…
1.3.6.1.4.1.20044.79.6.3.66Tablepme1008CtrllineLoopTablenot-accessiblecurrentList of pme1008CtrllineLoop Article
1.3.6.1.4.1.20044.79.6.3.66.1Rowpme1008CtrllineLoopEntrynot-accessiblecurrentRow definition for the pme1008CtrllineLoop table
1.3.6.1.4.1.20044.79.6.3.66.1.1Columnpme1008CtrllineLoopIndexread-onlycurrentIndex definition for the pme1008CtrllineLoop table
1.3.6.1.4.1.20044.79.6.3.66.1.2Columnpme1008CtrllineLoopPortnread-writecurrentLine Facility Loopback :This OID, when set at '1' puts the module in line loopback mode, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. Th…
1.3.6.1.4.1.20044.79.6.3.69Tablepme1008CtrlfecDisableTablenot-accessiblecurrentList of pme1008CtrlfecDisable Article
1.3.6.1.4.1.20044.79.6.3.69.1Rowpme1008CtrlfecDisableEntrynot-accessiblecurrentRow definition for the pme1008CtrlfecDisable table
1.3.6.1.4.1.20044.79.6.3.69.1.1Columnpme1008CtrlfecDisableIndexread-onlycurrentIndex definition for the pme1008CtrlfecDisable table
1.3.6.1.4.1.20044.79.6.3.69.1.2Columnpme1008CtrlfecDisablePortnread-writecurrentForward Error Correction Inhibition :This OID, when set, inhibits the Forward Error Correction feature on the line input <Help> This control enables/disables t…
1.3.6.1.4.1.20044.79.6.3.70Tablepme1008CtrllineBdiTablenot-accessiblecurrentList of pme1008CtrllineBdi Article
1.3.6.1.4.1.20044.79.6.3.70.1Rowpme1008CtrllineBdiEntrynot-accessiblecurrentRow definition for the pme1008CtrllineBdi table
1.3.6.1.4.1.20044.79.6.3.70.1.1Columnpme1008CtrllineBdiIndexread-onlycurrentIndex definition for the pme1008CtrllineBdi table
1.3.6.1.4.1.20044.79.6.3.70.1.2Columnpme1008CtrllineBdiPortnread-writecurrentOTU2e-BDI :Label <Help> This control inserts a Line BDI
1.3.6.1.4.1.20044.79.7Nodepme1008ri
1.3.6.1.4.1.20044.79.7.1Nodepme1008riTable
1.3.6.1.4.1.20044.79.7.1.1Tablepme1008RinvSfpTablenot-accessiblecurrentList of the SFPs on the selected module
1.3.6.1.4.1.20044.79.7.1.1.1Rowpme1008RinvSfpEntrynot-accessiblecurrentRow definition for the SFP table
1.3.6.1.4.1.20044.79.7.1.1.1.1Columnpme1008RinvSfpIndexread-onlycurrentIndex for SFP table
1.3.6.1.4.1.20044.79.7.1.1.1.2Columnpme1008Rinvsfpread-onlycurrentInventory for the SFP: This OID contains the inventory for the SFP
1.3.6.1.4.1.20044.79.7.1.2Tablepme1008RinvLineTablenot-accessiblecurrentList of the SFPs on the selected module
1.3.6.1.4.1.20044.79.7.1.2.1Rowpme1008RinvLineEntrynot-accessiblecurrentRow definition for the SFP table
1.3.6.1.4.1.20044.79.7.1.2.1.1Columnpme1008RinvLineIndexread-onlycurrentIndex for SFP table
1.3.6.1.4.1.20044.79.7.1.2.1.2Columnpme1008RinvxfpLineread-onlycurrentInventory for the XFP: This OID contains the inventory for the XFP
1.3.6.1.4.1.20044.79.7.2Scalarpme1008RinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.79.7.3Scalarpme1008RinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.79.7.4Scalarpme1008RinvModulePlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.79.7.5Scalarpme1008RinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.79.7.6Scalarpme1008RinvGwPlatformread-onlycurrentGW platform description: This OID contains the description of the Gateware platform.
1.3.6.1.4.1.20044.79.8Nodepme1008download
1.3.6.1.4.1.20044.79.8.1Nodepme1008DwlOther
1.3.6.1.4.1.20044.79.8.1.0Nodepme1008DwlrestartProcess
1.3.6.1.4.1.20044.79.8.1.0.1Scalarpme1008DwlWarmRestartProcessedread-onlycurrentWarm Restart :This OID indicates that the module last restart was a Warm RESTART
1.3.6.1.4.1.20044.79.8.1.0.2Scalarpme1008DwlColdRestartProcessedread-onlycurrentCold Restart :This OID indicates that the module last restart was a Cold RESTART
1.3.6.1.4.1.20044.79.8.1.1Nodepme1008DwlswBanksUsed
1.3.6.1.4.1.20044.79.8.1.1.1Scalarpme1008DwlSwBank1Usedread-onlycurrentSW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby
1.3.6.1.4.1.20044.79.8.1.1.2Scalarpme1008DwlSwBank2Usedread-onlycurrentSW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby
1.3.6.1.4.1.20044.79.8.1.1.5Scalarpme1008DwlSwBank1Notemptyread-onlycurrentSW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package
1.3.6.1.4.1.20044.79.8.1.1.6Scalarpme1008DwlSwBank2Notemptyread-onlycurrentSW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package
1.3.6.1.4.1.20044.79.8.1.2Nodepme1008DwlgwBanksUsed
1.3.6.1.4.1.20044.79.8.1.2.1Scalarpme1008DwlGwBank1Usedread-onlycurrentGW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby
1.3.6.1.4.1.20044.79.8.1.2.2Scalarpme1008DwlGwBank2Usedread-onlycurrentGW bank 2 active :This OID indicates the module is working on GW bank 2
1.3.6.1.4.1.20044.79.8.1.2.3Scalarpme1008DwlGwBank3Usedread-onlycurrentGW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby
1.3.6.1.4.1.20044.79.8.1.2.4Scalarpme1008DwlGwBank4Usedread-onlycurrentGW bank 4 active :This OID indicates the module is working on GW bank 4
1.3.6.1.4.1.20044.79.8.1.2.5Scalarpme1008DwlGwBank1Notemptyread-onlycurrentGW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package
1.3.6.1.4.1.20044.79.8.1.2.6Scalarpme1008DwlGwBank2Notemptyread-onlycurrentGW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2
1.3.6.1.4.1.20044.79.8.1.2.7Scalarpme1008DwlGwBank3Notemptyread-onlycurrentGW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package
1.3.6.1.4.1.20044.79.8.1.2.8Scalarpme1008DwlGwBank4Notemptyread-onlycurrentGW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4
1.3.6.1.4.1.20044.79.8.2Nodepme1008DwlClient
1.3.6.1.4.1.20044.79.8.3Nodepme1008DwlLine
1.3.6.1.4.1.20044.79.9Nodepme1008Config
1.3.6.1.4.1.20044.79.9.1Nodepme1008CfgStartup
1.3.6.1.4.1.20044.79.9.1.1Tablepme1008CfgClientStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.79.9.1.1.1Rowpme1008CfgClientStartupEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.79.9.1.1.1.1Columnpme1008CfgClientStartupIndexread-onlycurrentIndex definition for the clientStartup table
1.3.6.1.4.1.20044.79.9.1.1.1.3Columnpme1008CfgSystConfPortPortnread-writecurrentDefault Settings on Client Port :This register configures the default initialisation settings on the port.
1.3.6.1.4.1.20044.79.9.1.1.1.4Columnpme1008CfgNetConfPortPortnread-writecurrentDefault Settings on Client Port :This register configures the default initialisation settings on the port.
1.3.6.1.4.1.20044.79.9.1.1.1.14Columnpme1008CfgOptionsPortPortnread-writecurrentDefault Options on Client Port :This register configures the default options on the port.
1.3.6.1.4.1.20044.79.9.1.2Tablepme1008CfgLinexr1StartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.79.9.1.2.1Rowpme1008CfgLinexr1StartupEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.79.9.1.2.1.1Columnpme1008CfgLinexr1StartupIndexread-onlycurrentIndex definition for the linexr1Startup table
1.3.6.1.4.1.20044.79.9.1.2.1.3Columnpme1008CfgSystConfLinePortnread-writecurrentDefault Settings on Line :This register configures the default initialisation settings on Line
1.3.6.1.4.1.20044.79.9.1.2.1.14Columnpme1008CfgOptionsLinePortnread-writecurrentDefault Options on Line :This register configures the default options on the line
1.3.6.1.4.1.20044.79.9.1.3Tablepme1008CfgOtxtlhTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.79.9.1.3.1Rowpme1008CfgOtxtlhEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.79.9.1.3.1.1Columnpme1008CfgOtxtlhIndexread-onlycurrentIndex definition for the otxtlh table
1.3.6.1.4.1.20044.79.9.1.3.1.3Columnpme1008CfgLineControlsPortnread-writedeprecatedDefault Line settings :This register configures the start-up settings on the ports
1.3.6.1.4.1.20044.79.9.1.3.1.6Columnpme1008CfgLinePwrLaserPortnread-writecurrentDefault Line output Power :This register configures the start-up output power of the client transceiver (Unit = dBm)
1.3.6.1.4.1.20044.79.9.1.3.1.7Columnpme1008CfgLineFCurrentPortnread-writecurrentDefault Line transceiver Channel :This register configures the start-up laser channel of the client transceiver
1.3.6.1.4.1.20044.79.9.1.3.1.8Columnpme1008CfgLineGridCurrentPortnread-writecurrentDefault Line transceiver Grid :This register configures the start-up laser grid of the client transceiver
1.3.6.1.4.1.20044.79.9.1.3.1.9Columnpme1008CfgLineFoPortnread-writecurrentDefault Line first Frequency :This register configures the start-up first frequency of the client transceiver
1.3.6.1.4.1.20044.79.9.2Nodepme1008CfgLabels
1.3.6.1.4.1.20044.79.9.2.1Tablepme1008CfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.79.9.2.1.1Rowpme1008CfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.79.9.2.1.1.1Columnpme1008CfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.79.9.2.1.1.3Columnpme1008CfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.79.9.2.2Tablepme1008CfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.79.9.2.2.1Rowpme1008CfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.79.9.2.2.1.1Columnpme1008CfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.79.9.2.2.1.3Columnpme1008CfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.79.9.3Nodepme1008CfgOther
1.3.6.1.4.1.20044.79.9.3.1Nodepme1008tablemoduleOther
1.3.6.1.4.1.20044.79.9.3.1.2Scalarpme1008Cfgmoderead-writecurrentDefault settings on Module :This register selects the configuration mode of the module
1.3.6.1.4.1.20044.79.9.4Nodepme1008CfgOdu2Clienta
1.3.6.1.4.1.20044.79.9.4.1Tablepme1008CfgClientStartupOduTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.79.9.4.1.1Rowpme1008CfgClientStartupOduEntrynot-accessiblecurrentRow definition for the odu2Clienta table
1.3.6.1.4.1.20044.79.9.4.1.1.1Columnpme1008CfgClientStartupOduIndexread-onlycurrentIndex definition for the clientStartupOdu table
1.3.6.1.4.1.20044.79.9.4.1.1.3Columnpme1008CfgOdu2ReserveLsbPortnread-writecurrent:
1.3.6.1.4.1.20044.79.9.4.1.1.4Columnpme1008CfgOdu2DegthresholdPortnread-writecurrentODU2 Degrade Threshold :
1.3.6.1.4.1.20044.79.9.4.1.1.5Columnpme1008CfgOdu2DegmPortnread-writecurrentODU2 Degrade Confirmation :
1.3.6.1.4.1.20044.79.9.4.1.1.6Columnpme1008CfgOdu2SettingsPortnread-writecurrentODU2 Settings :
1.3.6.1.4.1.20044.79.9.5Nodepme1008CfgOtu2Line
1.3.6.1.4.1.20044.79.9.5.1Tablepme1008CfgLinexStartupOtuTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.79.9.5.1.1Rowpme1008CfgLinexStartupOtuEntrynot-accessiblecurrentRow definition for the otu2Line table
1.3.6.1.4.1.20044.79.9.5.1.1.1Columnpme1008CfgLinexStartupOtuIndexread-onlycurrentIndex definition for the linexStartupOtu table
1.3.6.1.4.1.20044.79.9.5.1.1.3Columnpme1008CfgOtu2ReserveMsbPortnread-writecurrent:
1.3.6.1.4.1.20044.79.9.5.1.1.4Columnpme1008CfgOtu2DegthresholdPortnread-writecurrentOTU2 Degrade Threshold :
1.3.6.1.4.1.20044.79.9.5.1.1.5Columnpme1008CfgOtu2DegmPortnread-writecurrentOTU2 Degrade Confirmation :
1.3.6.1.4.1.20044.79.9.5.1.1.6Columnpme1008CfgOtu2SettingsPortnread-writecurrentOTU2 Settings :
1.3.6.1.4.1.20044.79.9.6Nodepme1008CfgSapiTxClient
1.3.6.1.4.1.20044.79.9.6.1Tablepme1008CfgClientSapiTxOduTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.79.9.6.1.1Rowpme1008CfgClientSapiTxOduEntrynot-accessiblecurrentRow definition for the sapiTxClient table
1.3.6.1.4.1.20044.79.9.6.1.1.1Columnpme1008CfgClientSapiTxOduIndexread-onlycurrentIndex definition for the clientSapiTxOdu table
1.3.6.1.4.1.20044.79.9.6.1.1.3Columnpme1008CfgClientSapiTxSetupPortnread-writecurrentClient Transmitted SAPI :This register defines the value of the transmitted Trace Identifier on the line output
1.3.6.1.4.1.20044.79.9.7Nodepme1008CfgSapiExpClient
1.3.6.1.4.1.20044.79.9.7.1Tablepme1008CfgClientSapiExpOduTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.79.9.7.1.1Rowpme1008CfgClientSapiExpOduEntrynot-accessiblecurrentRow definition for the sapiExpClient table
1.3.6.1.4.1.20044.79.9.7.1.1.1Columnpme1008CfgClientSapiExpOduIndexread-onlycurrentIndex definition for the clientSapiExpOdu table
1.3.6.1.4.1.20044.79.9.7.1.1.3Columnpme1008CfgClientSapiExpSetupPortnread-writecurrentClient Expected SAPI :This register defines the value of the expected Trace Identifier on the line input
1.3.6.1.4.1.20044.79.9.8Nodepme1008CfgSapiAccClient
1.3.6.1.4.1.20044.79.9.8.1Tablepme1008CfgClientSapiAccOduTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.79.9.8.1.1Rowpme1008CfgClientSapiAccOduEntrynot-accessiblecurrentRow definition for the sapiAccClient table
1.3.6.1.4.1.20044.79.9.8.1.1.1Columnpme1008CfgClientSapiAccOduIndexread-onlycurrentIndex definition for the clientSapiAccOdu table
1.3.6.1.4.1.20044.79.9.8.1.1.3Columnpme1008CfgClientSapiAccSetupPortnread-writedeprecatedClient Accepted SAPI :This register defines the value of the accepted Trace Identifier on the line input
1.3.6.1.4.1.20044.79.9.9Nodepme1008CfgDapiTxClient
1.3.6.1.4.1.20044.79.9.9.1Tablepme1008CfgClientDapiTxOduTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.79.9.9.1.1Rowpme1008CfgClientDapiTxOduEntrynot-accessiblecurrentRow definition for the dapiTxClient table
1.3.6.1.4.1.20044.79.9.9.1.1.1Columnpme1008CfgClientDapiTxOduIndexread-onlycurrentIndex definition for the clientDapiTxOdu table
1.3.6.1.4.1.20044.79.9.9.1.1.3Columnpme1008CfgClientDapiTxSetupPortnread-writecurrentClient Transmitted DAPI :This register defines the value of the transmitted Trace Identifier on the line output
1.3.6.1.4.1.20044.79.9.10Nodepme1008CfgDapiExpClient
1.3.6.1.4.1.20044.79.9.10.1Tablepme1008CfgClientDapiExpOduTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.79.9.10.1.1Rowpme1008CfgClientDapiExpOduEntrynot-accessiblecurrentRow definition for the dapiExpClient table
1.3.6.1.4.1.20044.79.9.10.1.1.1Columnpme1008CfgClientDapiExpOduIndexread-onlycurrentIndex definition for the clientDapiExpOdu table
1.3.6.1.4.1.20044.79.9.10.1.1.3Columnpme1008CfgClientDapiExpSetupPortnread-writecurrentClient Expected DAPI :This register defines the value of the expected Trace Identifier on the line input
1.3.6.1.4.1.20044.79.9.11Nodepme1008CfgDapiAccClient
1.3.6.1.4.1.20044.79.9.11.1Tablepme1008CfgClientDapiAccOduTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.79.9.11.1.1Rowpme1008CfgClientDapiAccOduEntrynot-accessiblecurrentRow definition for the dapiAccClient table
1.3.6.1.4.1.20044.79.9.11.1.1.1Columnpme1008CfgClientDapiAccOduIndexread-onlycurrentIndex definition for the clientDapiAccOdu table
1.3.6.1.4.1.20044.79.9.11.1.1.3Columnpme1008CfgClientDapiAccSetupPortnread-writedeprecatedClient Accepted DAPI :This register defines the value of the accepted Trace Identifier on the line input
1.3.6.1.4.1.20044.79.9.12Nodepme1008CfgSapiTxLine
1.3.6.1.4.1.20044.79.9.12.1Tablepme1008CfgLineSapiTxOtuTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.79.9.12.1.1Rowpme1008CfgLineSapiTxOtuEntrynot-accessiblecurrentRow definition for the sapiTxLine table
1.3.6.1.4.1.20044.79.9.12.1.1.1Columnpme1008CfgLineSapiTxOtuIndexread-onlycurrentIndex definition for the lineSapiTxOtu table
1.3.6.1.4.1.20044.79.9.12.1.1.3Columnpme1008CfgLineSapiTxSetupPortnread-writecurrentLine Transmitted SAPI :This register defines the value of the transmitted Trace Identifier on the line output
1.3.6.1.4.1.20044.79.9.13Nodepme1008CfgSapiExpLine
1.3.6.1.4.1.20044.79.9.13.1Tablepme1008CfgLineSapiExpOtuTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.79.9.13.1.1Rowpme1008CfgLineSapiExpOtuEntrynot-accessiblecurrentRow definition for the sapiExpLine table
1.3.6.1.4.1.20044.79.9.13.1.1.1Columnpme1008CfgLineSapiExpOtuIndexread-onlycurrentIndex definition for the lineSapiExpOtu table
1.3.6.1.4.1.20044.79.9.13.1.1.3Columnpme1008CfgLineSapiExpSetupPortnread-writecurrentLine Expected SAPI :This register defines the value of the expected Trace Identifier on the line input
1.3.6.1.4.1.20044.79.9.14Nodepme1008CfgSapiAccLine
1.3.6.1.4.1.20044.79.9.14.1Tablepme1008CfgLineSapiAccOtuTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.79.9.14.1.1Rowpme1008CfgLineSapiAccOtuEntrynot-accessiblecurrentRow definition for the sapiAccLine table
1.3.6.1.4.1.20044.79.9.14.1.1.1Columnpme1008CfgLineSapiAccOtuIndexread-onlycurrentIndex definition for the lineSapiAccOtu table
1.3.6.1.4.1.20044.79.9.14.1.1.3Columnpme1008CfgLineSapiAccSetupPortnread-writedeprecatedLine Accepted SAPI :This register defines the value of the accepted Trace Identifier on the line input
1.3.6.1.4.1.20044.79.9.15Nodepme1008CfgDapiTxLine
1.3.6.1.4.1.20044.79.9.15.1Tablepme1008CfgLineDapiTxOtuTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.79.9.15.1.1Rowpme1008CfgLineDapiTxOtuEntrynot-accessiblecurrentRow definition for the dapiTxLine table
1.3.6.1.4.1.20044.79.9.15.1.1.1Columnpme1008CfgLineDapiTxOtuIndexread-onlycurrentIndex definition for the lineDapiTxOtu table
1.3.6.1.4.1.20044.79.9.15.1.1.3Columnpme1008CfgLineDapiTxSetupPortnread-writecurrentLine Transmitted DAPI :This register defines the value of the transmitted Trace Identifier on the line output
1.3.6.1.4.1.20044.79.9.16Nodepme1008CfgDapiExpLine
1.3.6.1.4.1.20044.79.9.16.1Tablepme1008CfgLineDapiExpOtuTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.79.9.16.1.1Rowpme1008CfgLineDapiExpOtuEntrynot-accessiblecurrentRow definition for the dapiExpLine table
1.3.6.1.4.1.20044.79.9.16.1.1.1Columnpme1008CfgLineDapiExpOtuIndexread-onlycurrentIndex definition for the lineDapiExpOtu table
1.3.6.1.4.1.20044.79.9.16.1.1.3Columnpme1008CfgLineDapiExpSetupPortnread-writecurrentLine Expected DAPI :This register defines the value of the expected Trace Identifier on the line input
1.3.6.1.4.1.20044.79.9.17Nodepme1008CfgDapiAccLine
1.3.6.1.4.1.20044.79.9.17.1Tablepme1008CfgLineDapiAccOtuTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.79.9.17.1.1Rowpme1008CfgLineDapiAccOtuEntrynot-accessiblecurrentRow definition for the dapiAccLine table
1.3.6.1.4.1.20044.79.9.17.1.1.1Columnpme1008CfgLineDapiAccOtuIndexread-onlycurrentIndex definition for the lineDapiAccOtu table
1.3.6.1.4.1.20044.79.9.17.1.1.3Columnpme1008CfgLineDapiAccSetupPortnread-writedeprecatedLine Accepted DAPI :This register defines the value of the accepted Trace Identifier on the line input
1.3.6.1.4.1.20044.79.9.18Nodepme1008CfgStartuptablefive
1.3.6.1.4.1.20044.79.9.18.1Tablepme1008CfgOtxtlhcapabilitiesTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.79.9.18.1.1Rowpme1008CfgOtxtlhcapabilitiesEntrynot-accessiblecurrentRow definition for the startuptablefive table
1.3.6.1.4.1.20044.79.9.18.1.1.1Columnpme1008CfgOtxtlhcapabilitiesIndexread-onlycurrentIndex definition for the otxtlhcapabilities table
1.3.6.1.4.1.20044.79.9.18.1.1.3Columnpme1008CfgComponentTypePortnread-onlycurrentComponent parameters :This OID defines the component parameters
1.3.6.1.4.1.20044.79.9.18.1.1.4Columnpme1008CfgMiscellaneousPortnread-onlycurrentMiscellaneous default settings :This OID defines the miscellaneous parameters
1.3.6.1.4.1.20044.79.9.18.1.1.5Columnpme1008CfgFirstChannelPortnread-onlycurrentNumber of the first channel of the component :This OID defines the first channel number of the PM
1.3.6.1.4.1.20044.79.9.18.1.1.6Columnpme1008CfgLastChannelPortnread-onlycurrentNumber of the last channel of the component :This OID defines the last channel number of the PM
1.3.6.1.4.1.20044.79.9.18.1.1.7Columnpme1008CfgGridPortnread-onlycurrentGrid value of the component :This OID defines the grid of the PM
1.3.6.1.4.1.20044.79.9.257Scalarpme1008CfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.79.10Nodepme1008traps
1.3.6.1.4.1.20044.79.10.2Scalarpme1008trapPortNumberread-onlycurrentLast port which generates a trap
1.3.6.1.4.1.20044.79.10.3Scalarpme1008trapLineNumberread-onlycurrentLast Line which generates a trap
1.3.6.1.4.1.20044.79.10.4Scalarpme1008trapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.79.10.30Notificationpme1008LineTrapNotUrgentGoesOncurrentNot urgent Line default is activated
1.3.6.1.4.1.20044.79.10.31Notificationpme1008LineTrapNotUrgentGoesOffcurrentNot urgent Line default disappeared
1.3.6.1.4.1.20044.79.10.32Notificationpme1008LineTrapUrgentGoesOncurrentUrgent Line default is activated
1.3.6.1.4.1.20044.79.10.33Notificationpme1008LineTrapUrgentGoesOffcurrentUrgent Line default disappeared
1.3.6.1.4.1.20044.79.10.34Notificationpme1008LineTrapCritGoesOncurrentCritical Line default is activated
1.3.6.1.4.1.20044.79.10.35Notificationpme1008LineTrapCritGoesOffcurrentCritical Line default disappeared
1.3.6.1.4.1.20044.79.10.40Notificationpme1008ClientTrapNotUrgentGoesOncurrentNot urgent client default is activated
1.3.6.1.4.1.20044.79.10.41Notificationpme1008ClientTrapNotUrgentGoesOffcurrentNot urgent client default disappeared
1.3.6.1.4.1.20044.79.10.42Notificationpme1008ClientTrapUrgentGoesOncurrentUrgent client default is activated
1.3.6.1.4.1.20044.79.10.43Notificationpme1008ClientTrapUrgentGoesOffcurrentUrgent client default disappeared
1.3.6.1.4.1.20044.79.10.44Notificationpme1008ClientTrapCritGoesOncurrentCritical client default is activated
1.3.6.1.4.1.20044.79.10.45Notificationpme1008ClientTrapCritGoesOffcurrentCritical client default disappeared
1.3.6.1.4.1.20044.79.10.50Notificationpme1008PowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.79.10.51Notificationpme1008PowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared
1.3.6.1.4.1.20044.79.11Nodepme1008Monitoring
1.3.6.1.4.1.20044.79.11.1Nodepme1008MonOther
1.3.6.1.4.1.20044.79.11.1.3Nodepme1008MonRmon
1.3.6.1.4.1.20044.79.11.1.3.359Scalarpme1008MonCountersResetread-writecurrentRMON Counters Reset:This OID resets and restarts all the RMON counters
1.3.6.1.4.1.20044.79.11.1.3.360Scalarpme1008MonCountersStopread-writecurrentRMON Counters stop:This OID stops all the RMON counters
1.3.6.1.4.1.20044.79.11.2Nodepme1008MonClient
1.3.6.1.4.1.20044.79.11.2.4Nodepme1008MonClientRmonCounter
1.3.6.1.4.1.20044.79.11.2.4.16Tablepme1008MonupRmonBytesCounterClientInputTablenot-accessiblecurrentList of pme1008MonupRmonBytesCounterClientInput Article
1.3.6.1.4.1.20044.79.11.2.4.16.1Rowpme1008MonupRmonBytesCounterClientInputEntrynot-accessiblecurrentRow definition for the pme1008MonupRmonBytesCounterClientInput table
1.3.6.1.4.1.20044.79.11.2.4.16.1.1Columnpme1008MonupRmonBytesCounterClientInputIndexread-onlycurrentIndex definition for the pme1008MonupRmonBytesCounterClientInput table
1.3.6.1.4.1.20044.79.11.2.4.16.1.2Columnpme1008MonupRmonBytesCounterClientInputValuePortnread-onlycurrentClient Input Bytes :This counter is increased each time a data byte is received on the client port <Help> This counter gives the number of bytes received on th…
1.3.6.1.4.1.20044.79.11.2.4.16.1.3Columnpme1008MonupRmonBytesCounterClientInputErrorPortnread-onlycurrentBytes Counter Error :This OID when set indicates the Bytes counter value is invalid on client port
1.3.6.1.4.1.20044.79.11.2.4.16.1.4Columnpme1008MonupRmonBytesCounterClientInputOverloadPortnread-onlycurrentBytes Counter Overload :This OID when set indicates a Bytes counter overload on client port
1.3.6.1.4.1.20044.79.11.2.4.32Tablepme1008MonupRmonCrcErrorsCounterClientInputTablenot-accessiblecurrentList of pme1008MonupRmonCrcErrorsCounterClientInput Article
1.3.6.1.4.1.20044.79.11.2.4.32.1Rowpme1008MonupRmonCrcErrorsCounterClientInputEntrynot-accessiblecurrentRow definition for the pme1008MonupRmonCrcErrorsCounterClientInput table
1.3.6.1.4.1.20044.79.11.2.4.32.1.1Columnpme1008MonupRmonCrcErrorsCounterClientInputIndexread-onlycurrentIndex definition for the pme1008MonupRmonCrcErrorsCounterClientInput table
1.3.6.1.4.1.20044.79.11.2.4.32.1.2Columnpme1008MonupRmonCrcErrorsCounterClientInputValuePortnread-onlycurrentClient Input CRC Errors :This counter is increased each time a B1/FCS error is detected on the client port <Help> This counter gives the number of B1/FCS Error…
1.3.6.1.4.1.20044.79.11.2.4.32.1.3Columnpme1008MonupRmonCrcErrorsCounterClientInputErrorPortnread-onlycurrentB1/FCS Errors Counter Error :This OID when set indicates the B1/FCS Errors counter value is invalid on client port
1.3.6.1.4.1.20044.79.11.2.4.32.1.4Columnpme1008MonupRmonCrcErrorsCounterClientInputOverloadPortnread-onlycurrentB1/FCS Errors Counter Overload :This OID when set indicates a B1/FCS Errors counter overload on client port
1.3.6.1.4.1.20044.79.11.2.4.48Tablepme1008MonupRmonPacketsCounterClientInputTablenot-accessiblecurrentList of pme1008MonupRmonPacketsCounterClientInput Article
1.3.6.1.4.1.20044.79.11.2.4.48.1Rowpme1008MonupRmonPacketsCounterClientInputEntrynot-accessiblecurrentRow definition for the pme1008MonupRmonPacketsCounterClientInput table
1.3.6.1.4.1.20044.79.11.2.4.48.1.1Columnpme1008MonupRmonPacketsCounterClientInputIndexread-onlycurrentIndex definition for the pme1008MonupRmonPacketsCounterClientInput table
1.3.6.1.4.1.20044.79.11.2.4.48.1.2Columnpme1008MonupRmonPacketsCounterClientInputValuePortnread-onlycurrentClient Input Packets :This counter is increased each time a packet is received on the client port <Help> This counter gives the number of packets received on t…
1.3.6.1.4.1.20044.79.11.2.4.48.1.3Columnpme1008MonupRmonPacketsCounterClientInputErrorPortnread-onlycurrentPackets Counter Error :This OID when set indicates the Packets counter value is invalid on client port
1.3.6.1.4.1.20044.79.11.2.4.48.1.4Columnpme1008MonupRmonPacketsCounterClientInputOverloadPortnread-onlycurrentPackets Counter Overload :This OID when set indicates a Packets counter overload on client port
1.3.6.1.4.1.20044.79.11.2.4.64Tablepme1008MonupRmonBroadcastCounterClientInputTablenot-accessiblecurrentList of pme1008MonupRmonBroadcastCounterClientInput Article
1.3.6.1.4.1.20044.79.11.2.4.64.1Rowpme1008MonupRmonBroadcastCounterClientInputEntrynot-accessiblecurrentRow definition for the pme1008MonupRmonBroadcastCounterClientInput table
1.3.6.1.4.1.20044.79.11.2.4.64.1.1Columnpme1008MonupRmonBroadcastCounterClientInputIndexread-onlycurrentIndex definition for the pme1008MonupRmonBroadcastCounterClientInput table
1.3.6.1.4.1.20044.79.11.2.4.64.1.2Columnpme1008MonupRmonBroadcastCounterClientInputValuePortnread-onlycurrentClient Input Broadcast Packets :This counter is increased each time a broadcast packet is received on the client port <Help> This counter gives the number of B…
1.3.6.1.4.1.20044.79.11.2.4.64.1.3Columnpme1008MonupRmonBroadcastCounterClientInputErrorPortnread-onlycurrentBroadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on client port
1.3.6.1.4.1.20044.79.11.2.4.64.1.4Columnpme1008MonupRmonBroadcastCounterClientInputOverloadPortnread-onlycurrentBroadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port
1.3.6.1.4.1.20044.79.11.2.4.80Tablepme1008MonupRmonMulticastCounterClientInputTablenot-accessiblecurrentList of pme1008MonupRmonMulticastCounterClientInput Article
1.3.6.1.4.1.20044.79.11.2.4.80.1Rowpme1008MonupRmonMulticastCounterClientInputEntrynot-accessiblecurrentRow definition for the pme1008MonupRmonMulticastCounterClientInput table
1.3.6.1.4.1.20044.79.11.2.4.80.1.1Columnpme1008MonupRmonMulticastCounterClientInputIndexread-onlycurrentIndex definition for the pme1008MonupRmonMulticastCounterClientInput table
1.3.6.1.4.1.20044.79.11.2.4.80.1.2Columnpme1008MonupRmonMulticastCounterClientInputValuePortnread-onlycurrentClient Input Multicast Packets :This counter is increased each time a Multicast packet is received on the client port <Help> This counter gives the number of M…
1.3.6.1.4.1.20044.79.11.2.4.80.1.3Columnpme1008MonupRmonMulticastCounterClientInputErrorPortnread-onlycurrentMulticast Counter Error :This OID when set indicates the Multicast counter value is invalid on client port
1.3.6.1.4.1.20044.79.11.2.4.80.1.4Columnpme1008MonupRmonMulticastCounterClientInputOverloadPortnread-onlycurrentMulticast Counter Overload :This OID when set indicates a Multicast counter overload on client port
1.3.6.1.4.1.20044.79.11.2.4.96Tablepme1008MonupRmonPauseFrameCounterClientInputTablenot-accessiblecurrentList of pme1008MonupRmonPauseFrameCounterClientInput Article
1.3.6.1.4.1.20044.79.11.2.4.96.1Rowpme1008MonupRmonPauseFrameCounterClientInputEntrynot-accessiblecurrentRow definition for the pme1008MonupRmonPauseFrameCounterClientInput table
1.3.6.1.4.1.20044.79.11.2.4.96.1.1Columnpme1008MonupRmonPauseFrameCounterClientInputIndexread-onlycurrentIndex definition for the pme1008MonupRmonPauseFrameCounterClientInput table
1.3.6.1.4.1.20044.79.11.2.4.96.1.2Columnpme1008MonupRmonPauseFrameCounterClientInputValuePortnread-onlycurrentClient Input Pause Frames :This counter is increased each time a Pause frame is received on the client port <Help> This counter gives the number of Pause frame…
1.3.6.1.4.1.20044.79.11.2.4.96.1.3Columnpme1008MonupRmonPauseFrameCounterClientInputErrorPortnread-onlycurrentPause Counter Error :This OID when set indicates the Pause counter value is invalid on client port
1.3.6.1.4.1.20044.79.11.2.4.96.1.4Columnpme1008MonupRmonPauseFrameCounterClientInputOverloadPortnread-onlycurrentPause Counter Overload :This OID when set indicates a Pause counter overload on client port
1.3.6.1.4.1.20044.79.11.2.4.224Tablepme1008MondwRmonCrcErrorsCounterClientOutputTablenot-accessiblecurrentList of pme1008MondwRmonCrcErrorsCounterClientOutput Article
1.3.6.1.4.1.20044.79.11.2.4.224.1Rowpme1008MondwRmonCrcErrorsCounterClientOutputEntrynot-accessiblecurrentRow definition for the pme1008MondwRmonCrcErrorsCounterClientOutput table
1.3.6.1.4.1.20044.79.11.2.4.224.1.1Columnpme1008MondwRmonCrcErrorsCounterClientOutputIndexread-onlycurrentIndex definition for the pme1008MondwRmonCrcErrorsCounterClientOutput table
1.3.6.1.4.1.20044.79.11.2.4.224.1.2Columnpme1008MondwRmonCrcErrorsCounterClientOutputValuePortnread-onlycurrentClient Output B1/CRC Errors :This counter is increased each time a B1/FCS error is detected on the output client port <Help> This counter gives the number of B…
1.3.6.1.4.1.20044.79.11.2.4.224.1.3Columnpme1008MondwRmonCrcErrorsCounterClientOutputErrorPortnread-onlycurrentOutput B1/FCS Errors Counter Error :This OID when set indicates the output B1/FCS Errors counter value is invalid on client port
1.3.6.1.4.1.20044.79.11.2.4.224.1.4Columnpme1008MondwRmonCrcErrorsCounterClientOutputOverloadPortnread-onlycurrentOutput B1/FCS Errors Counter Overload :This OID when set indicates an output B1/FCS Errors counter overload on client port
1.3.6.1.4.1.20044.79.11.2.4.240Tablepme1008MondwRmonPacketsCounterClientOutputTablenot-accessiblecurrentList of pme1008MondwRmonPacketsCounterClientOutput Article
1.3.6.1.4.1.20044.79.11.2.4.240.1Rowpme1008MondwRmonPacketsCounterClientOutputEntrynot-accessiblecurrentRow definition for the pme1008MondwRmonPacketsCounterClientOutput table
1.3.6.1.4.1.20044.79.11.2.4.240.1.1Columnpme1008MondwRmonPacketsCounterClientOutputIndexread-onlycurrentIndex definition for the pme1008MondwRmonPacketsCounterClientOutput table
1.3.6.1.4.1.20044.79.11.2.4.240.1.2Columnpme1008MondwRmonPacketsCounterClientOutputValuePortnread-onlycurrentClient Output Packets :This counter is increased each time a packet is transmitted on the client port. <Help> This counter gives the number of packets detected…
1.3.6.1.4.1.20044.79.11.2.4.240.1.3Columnpme1008MondwRmonPacketsCounterClientOutputErrorPortnread-onlycurrentOutput Packets Counter Error :This OID when set indicates the output Packets counter value is invalid on client port
1.3.6.1.4.1.20044.79.11.2.4.240.1.4Columnpme1008MondwRmonPacketsCounterClientOutputOverloadPortnread-onlycurrentOutput Packets Counter Overload :This OID when set indicates an output Packets counter overload on client port
Type Definitions
NameSyntaxStatusDescription
Pme1008ClientProtocolINTEGER { protocolclientvalue2(2), protocolclientvalue3(3), protocolclientvalue4(4), protocolclientvalue6(6), protocolclientvalue7(7) }currentDifferent values on the protocol on the client ports
Pme1008DccModeINTEGER { dccNo(0), dccLine1(1), dccLine2(2) }currentMode for DCC
Pme1008LineChannelINTEGERcurrentChannel selection on transceiver Line ports
Pme1008Odu2SapiModeINTEGER { off(0), sapi(1), dapi(2), sapidapi(3) }currentMode for SAPI-DAPI
Pme1008Otu2SapiModeINTEGER { off(0), sapi(1), dapi(2), sapidapi(3) }currentMode for SAPI-DAPI
Pme1008OtxGridINTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50) }currentDifferent grids on client and line ports