EKINOPS-Pmlma10-MIB
414 objects
Creation.
Imported Objects
| EKINOPS-MIB | EkiApiState EkiMeasureType EkiMode ekinops EkiOnOff EkiProtocol EkiState EkiSynchroMode |
| SNMPv2-SMI | Counter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20044.68 | IdentitymodulePmlma10 | Creation. | ||
| 1.3.6.1.4.1.20044.68.2 | Nodepmlma10alarms | |||
| 1.3.6.1.4.1.20044.68.2.1 | Nodepmlma10AlmOther | |||
| 1.3.6.1.4.1.20044.68.2.1.1 | Nodepmlma10AlmOtherNurg | |||
| 1.3.6.1.4.1.20044.68.2.1.1.2 | Nodepmlma10AlmsynthAlm2 | |||
| 1.3.6.1.4.1.20044.68.2.1.1.2.1 | Scalarpmlma10AlmConfTableSave | read-only | current | PM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> infor… |
| 1.3.6.1.4.1.20044.68.2.1.1.2.2 | Scalarpmlma10AlmInvUpload | read-only | current | Inventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> informationalStatus(1000) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.68.2.1.1.2.3 | Scalarpmlma10AlmConfTableLoad | read-only | current | PM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> informationalStat… |
| 1.3.6.1.4.1.20044.68.2.1.1.2.4 | Scalarpmlma10AlmCorrelatOff | read-only | current | Not Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> informationalStatus(1000) <Alarmtype… |
| 1.3.6.1.4.1.20044.68.2.1.2 | Nodepmlma10AlmOtherUrg | |||
| 1.3.6.1.4.1.20044.68.2.1.3 | Nodepmlma10AlmOtherCrit | |||
| 1.3.6.1.4.1.20044.68.2.1.3.0 | Nodepmlma10AlmsynthAlm0 | |||
| 1.3.6.1.4.1.20044.68.2.1.3.0.9 | Scalarpmlma10AlmModGlobFail | read-only | current | Module Failure :This OID is set on detection of a failure originating from the RM <Help> This alarm is set on detection of a failure originating from the equip… |
| 1.3.6.1.4.1.20044.68.2.1.3.0.15 | Scalarpmlma10AlmDefFuseA | read-only | current | Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.68.2.1.3.0.16 | Scalarpmlma10AlmDefFuseB | read-only | current | Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.68.2.2 | Nodepmlma10AlmClient | |||
| 1.3.6.1.4.1.20044.68.2.2.1 | Nodepmlma10AlmClientNurg | |||
| 1.3.6.1.4.1.20044.68.2.2.1.232 | Tablepmlma10AlmclientSfpWarnDdmTable | not-accessible | current | List of pmlma10AlmclientSfpWarnDdm Article |
| 1.3.6.1.4.1.20044.68.2.2.1.232.1 | Rowpmlma10AlmclientSfpWarnDdmEntry | not-accessible | current | Row definition for the pmlma10AlmclientSfpWarnDdm table |
| 1.3.6.1.4.1.20044.68.2.2.1.232.1.1 | Columnpmlma10AlmclientSfpWarnDdmIndex | read-only | current | Index definition for the pmlma10AlmclientSfpWarnDdm table |
| 1.3.6.1.4.1.20044.68.2.2.1.232.1.2 | Columnpmlma10AlmClientTxPwLowWngPortn | read-only | current | Client Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning … |
| 1.3.6.1.4.1.20044.68.2.2.1.232.1.3 | Columnpmlma10AlmClientTxPwrHighWngPortn | read-only | current | Client Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warnin… |
| 1.3.6.1.4.1.20044.68.2.2.1.232.1.4 | Columnpmlma10AlmClientTxBiasLowWngPortn | read-only | current | Client Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warnin… |
| 1.3.6.1.4.1.20044.68.2.2.1.232.1.5 | Columnpmlma10AlmClientTxBiasHighWngPortn | read-only | current | Client Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warn… |
| 1.3.6.1.4.1.20044.68.2.2.1.232.1.6 | Columnpmlma10AlmClientVccLowWngPortn | read-only | current | Client Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Warn… |
| 1.3.6.1.4.1.20044.68.2.2.1.232.1.7 | Columnpmlma10AlmClientVccHighWngPortn | read-only | current | Client Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Wa… |
| 1.3.6.1.4.1.20044.68.2.2.1.232.1.8 | Columnpmlma10AlmClientTempLowWngPortn | read-only | current | Client Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indic… |
| 1.3.6.1.4.1.20044.68.2.2.1.232.1.9 | Columnpmlma10AlmClientTempHighWngPortn | read-only | current | Client Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning ind… |
| 1.3.6.1.4.1.20044.68.2.2.1.232.1.16 | Columnpmlma10AlmClientRxPwrLowWngPortn | read-only | current | Client Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning i… |
| 1.3.6.1.4.1.20044.68.2.2.1.232.1.17 | Columnpmlma10AlmClientRxPwrHighWngPortn | read-only | current | Client Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning… |
| 1.3.6.1.4.1.20044.68.2.2.2 | Nodepmlma10AlmClientUrg | |||
| 1.3.6.1.4.1.20044.68.2.2.2.88 | Tablepmlma10AlmclientHostLaneFaultTable | not-accessible | current | List of pmlma10AlmclientHostLaneFault Article |
| 1.3.6.1.4.1.20044.68.2.2.2.88.1 | Rowpmlma10AlmclientHostLaneFaultEntry | not-accessible | current | Row definition for the pmlma10AlmclientHostLaneFault table |
| 1.3.6.1.4.1.20044.68.2.2.2.88.1.1 | Columnpmlma10AlmclientHostLaneFaultIndex | read-only | current | Index definition for the pmlma10AlmclientHostLaneFault table |
| 1.3.6.1.4.1.20044.68.2.2.2.88.1.2 | Columnpmlma10AlmClientLossOfSyncPortn | read-only | current | Client Frame Alignment Loss :This OID indicates the module is not aligned with the incoming Client signal <Help> Alarm indicating the module is not aligned wit… |
| 1.3.6.1.4.1.20044.68.2.2.2.88.1.3 | Columnpmlma10AlmClientInputLossOfSigPortn | read-only | current | Client Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Client Trscv <Help> Alarm indicating a Loss of Signal is detected on the Cl… |
| 1.3.6.1.4.1.20044.68.2.2.2.88.1.7 | Columnpmlma10AlmClientCsfDetectedPortn | read-only | current | Client Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client… |
| 1.3.6.1.4.1.20044.68.2.2.2.88.1.11 | Columnpmlma10AlmClientLaneTxFifoErrorPortn | read-only | current | Client Tx FIFO Error :This OID indicates a Tx FIFO Error on the Client Trscv <Help> Alarm indicating a Tx FIFO Error on the Client Trscv <Condtype> CLIENT_LANE… |
| 1.3.6.1.4.1.20044.68.2.2.2.216 | Tablepmlma10AlmclientSfpAlmDdmTable | not-accessible | current | List of pmlma10AlmclientSfpAlmDdm Article |
| 1.3.6.1.4.1.20044.68.2.2.2.216.1 | Rowpmlma10AlmclientSfpAlmDdmEntry | not-accessible | current | Row definition for the pmlma10AlmclientSfpAlmDdm table |
| 1.3.6.1.4.1.20044.68.2.2.2.216.1.1 | Columnpmlma10AlmclientSfpAlmDdmIndex | read-only | current | Index definition for the pmlma10AlmclientSfpAlmDdm table |
| 1.3.6.1.4.1.20044.68.2.2.2.216.1.2 | Columnpmlma10AlmClientTxPwrLowAlaPortn | read-only | current | Client Trscv Tx Power Low :This OID indicates that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in… |
| 1.3.6.1.4.1.20044.68.2.2.2.216.1.3 | Columnpmlma10AlmClientTxPwrHighAlaPortn | read-only | current | Client Trscv Tx Power High :This OID indicates that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm … |
| 1.3.6.1.4.1.20044.68.2.2.2.216.1.4 | Columnpmlma10AlmClientTxBiasLowAlaPortn | read-only | current | Client Trscv Bias Low :This OID indicates that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm … |
| 1.3.6.1.4.1.20044.68.2.2.2.216.1.5 | Columnpmlma10AlmClientTxBiasHighAlaPortn | read-only | current | Client Trscv Bias High :This OID indicates that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM <Help> Alar… |
| 1.3.6.1.4.1.20044.68.2.2.2.216.1.6 | Columnpmlma10AlmClientVccLowAlaPortn | read-only | current | Client Trscv Power Supply Low :This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM <Help> Alar… |
| 1.3.6.1.4.1.20044.68.2.2.2.216.1.7 | Columnpmlma10AlmClientVccHighAlaPortn | read-only | current | Client Trscv Power Supply High :This OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM <Help> Al… |
| 1.3.6.1.4.1.20044.68.2.2.2.216.1.8 | Columnpmlma10AlmClientTempLowAlaPortn | read-only | current | Client Trscv Temp Low :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicat… |
| 1.3.6.1.4.1.20044.68.2.2.2.216.1.9 | Columnpmlma10AlmClientTempHighAlaPortn | read-only | current | Client Trscv Temp High :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indic… |
| 1.3.6.1.4.1.20044.68.2.2.2.216.1.16 | Columnpmlma10AlmClientRxPwrLowAlaPortn | read-only | current | Client Trscv Rx Power Low :This OID indicates that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm ind… |
| 1.3.6.1.4.1.20044.68.2.2.2.216.1.17 | Columnpmlma10AlmClientRxPwrHighAlaPortn | read-only | current | Client Trscv Rx Power High :This OID indicates that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm i… |
| 1.3.6.1.4.1.20044.68.2.2.3 | Nodepmlma10AlmClientCrit | |||
| 1.3.6.1.4.1.20044.68.2.2.3.8 | Tablepmlma10AlmsynthAlmPortTable | not-accessible | current | List of pmlma10AlmsynthAlmPort Article |
| 1.3.6.1.4.1.20044.68.2.2.3.8.1 | Rowpmlma10AlmsynthAlmPortEntry | not-accessible | current | Row definition for the pmlma10AlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.68.2.2.3.8.1.1 | Columnpmlma10AlmsynthAlmPortIndex | read-only | current | Index definition for the pmlma10AlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.68.2.2.3.8.1.2 | Columnpmlma10AlmSfpAbsentPortn | read-only | current | Client Optical Module Absent :This OID indicates that the Transceiver is not present in the client port. <Help> This alarm indicates if the client transceiver … |
| 1.3.6.1.4.1.20044.68.2.2.3.8.1.3 | Columnpmlma10AlmDdmAbsentPortn | read-only | current | DDM Supported On Client Trscv :This OID indicates that the Client transceiver supports the Digital Diagnostic Monitoring function <Help> This status indicates … |
| 1.3.6.1.4.1.20044.68.2.2.3.8.1.5 | Columnpmlma10AlmHwFailAccPortn | read-only | current | Client HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Help> This alarm indicates a failure on client port, most pro… |
| 1.3.6.1.4.1.20044.68.2.2.3.8.1.6 | Columnpmlma10AlmDwLsdPortn | read-only | current | Client Trscv Laser Shutdown :This OID indicates the Client transceiver laser is shutdown <Help> This status indicates if the client transceiver laser is shutdo… |
| 1.3.6.1.4.1.20044.68.2.2.3.8.1.7 | Columnpmlma10AlmClientLocalOosPortn | read-only | current | Local Client Port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local c… |
| 1.3.6.1.4.1.20044.68.2.2.3.8.1.8 | Columnpmlma10AlmClientRemoteOosPortn | read-only | current | Remote Client Port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the remot… |
| 1.3.6.1.4.1.20044.68.2.2.3.8.1.9 | Columnpmlma10AlmDwCaisPortn | read-only | current | Client AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indicates if a Client Alarm Indication Signal is… |
| 1.3.6.1.4.1.20044.68.2.2.3.8.1.10 | Columnpmlma10AlmSfpDdmWarningPortn | read-only | current | Warning On Client Trscv DDM :This OID indicates a warning is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Warning has be… |
| 1.3.6.1.4.1.20044.68.2.2.3.8.1.11 | Columnpmlma10AlmSfpDdmAlmPortn | read-only | current | Alarm On Client Trscv DDM :This OID indicates an alarm is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Alarm has been de… |
| 1.3.6.1.4.1.20044.68.2.2.3.8.1.13 | Columnpmlma10AlmFailAccPortn | read-only | current | Client Access Fail :This OID indicates a failure on the Client port <Help> This alarm indicates a failure on the Client port <Condtype> FAIL_ACC_1 <Probcause> … |
| 1.3.6.1.4.1.20044.68.2.2.3.8.1.17 | Columnpmlma10AlmUpCsfPortn | read-only | current | Client Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu… |
| 1.3.6.1.4.1.20044.68.2.3 | Nodepmlma10AlmLine | |||
| 1.3.6.1.4.1.20044.68.2.3.1 | Nodepmlma10AlmLineNurg | |||
| 1.3.6.1.4.1.20044.68.2.3.2 | Nodepmlma10AlmLineUrg | |||
| 1.3.6.1.4.1.20044.68.2.3.2.104 | Tablepmlma10AlmlineNetworkLaneAlarmWarning1Table | not-accessible | current | List of pmlma10AlmlineNetworkLaneAlarmWarning1 Article |
| 1.3.6.1.4.1.20044.68.2.3.2.104.1 | Rowpmlma10AlmlineNetworkLaneAlarmWarning1Entry | not-accessible | current | Row definition for the pmlma10AlmlineNetworkLaneAlarmWarning1 table |
| 1.3.6.1.4.1.20044.68.2.3.2.104.1.1 | Columnpmlma10AlmlineNetworkLaneAlarmWarning1Index | read-only | current | Index definition for the pmlma10AlmlineNetworkLaneAlarmWarning1 table |
| 1.3.6.1.4.1.20044.68.2.3.2.104.1.2 | Columnpmlma10AlmLineTxPwrLowAlaPortn | read-only | current | Line Trscv Tx Power Low :This OID indicates that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indi… |
| 1.3.6.1.4.1.20044.68.2.3.2.104.1.3 | Columnpmlma10AlmLineTxPwrHighAlaPortn | read-only | current | Line Trscv Tx Power High :This OID indicates that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm in… |
| 1.3.6.1.4.1.20044.68.2.3.2.104.1.4 | Columnpmlma10AlmLineTxBiasLowAlaPortn | read-only | current | Line Trscv Bias Low :This OID indicates that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in… |
| 1.3.6.1.4.1.20044.68.2.3.2.104.1.5 | Columnpmlma10AlmLineTxBiasHighAlaPortn | read-only | current | Line Trscv Bias High :This OID indicates that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm … |
| 1.3.6.1.4.1.20044.68.2.3.2.104.1.6 | Columnpmlma10AlmLineVccLowAlaPortn | read-only | current | Line Trscv Power Supply Low :This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm … |
| 1.3.6.1.4.1.20044.68.2.3.2.104.1.7 | Columnpmlma10AlmLineVccHighAlaPortn | read-only | current | Line Trscv Power Supply High :This OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM <Help> Alar… |
| 1.3.6.1.4.1.20044.68.2.3.2.104.1.8 | Columnpmlma10AlmLineTempLowAlaPortn | read-only | current | Line Trscv Temp Low :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicatin… |
| 1.3.6.1.4.1.20044.68.2.3.2.104.1.9 | Columnpmlma10AlmLineTempHighAlaPortn | read-only | current | Line Trscv Temp High :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indicat… |
| 1.3.6.1.4.1.20044.68.2.3.2.104.1.16 | Columnpmlma10AlmLineRxPwrLowAlaPortn | read-only | current | Line Trscv Rx Power Low :This OID indicates that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indic… |
| 1.3.6.1.4.1.20044.68.2.3.2.104.1.17 | Columnpmlma10AlmLineRxPwrHighAlaPortn | read-only | current | Line Trscv Rx Power High :This OID indicates that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm ind… |
| 1.3.6.1.4.1.20044.68.2.3.2.120 | Tablepmlma10AlmlineNetworkLaneAlarmWarning2Table | not-accessible | current | List of pmlma10AlmlineNetworkLaneAlarmWarning2 Article |
| 1.3.6.1.4.1.20044.68.2.3.2.120.1 | Rowpmlma10AlmlineNetworkLaneAlarmWarning2Entry | not-accessible | current | Row definition for the pmlma10AlmlineNetworkLaneAlarmWarning2 table |
| 1.3.6.1.4.1.20044.68.2.3.2.120.1.1 | Columnpmlma10AlmlineNetworkLaneAlarmWarning2Index | read-only | current | Index definition for the pmlma10AlmlineNetworkLaneAlarmWarning2 table |
| 1.3.6.1.4.1.20044.68.2.3.2.120.1.2 | Columnpmlma10AlmLineTxPwLowWngPortn | read-only | current | Line Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning in… |
| 1.3.6.1.4.1.20044.68.2.3.2.120.1.3 | Columnpmlma10AlmLineTxPwrHighWngPortn | read-only | current | Line Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warning … |
| 1.3.6.1.4.1.20044.68.2.3.2.120.1.4 | Columnpmlma10AlmLineTxBiasLowWngPortn | read-only | current | Line Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warning … |
| 1.3.6.1.4.1.20044.68.2.3.2.120.1.5 | Columnpmlma10AlmLineTxBiasHighWngPortn | read-only | current | Line Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warnin… |
| 1.3.6.1.4.1.20044.68.2.3.2.120.1.6 | Columnpmlma10AlmLineVccLowWngPortn | read-only | current | Line Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Warnin… |
| 1.3.6.1.4.1.20044.68.2.3.2.120.1.7 | Columnpmlma10AlmLineVccHighWngPortn | read-only | current | Line Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Warn… |
| 1.3.6.1.4.1.20044.68.2.3.2.120.1.8 | Columnpmlma10AlmLineTempLowWngPortn | read-only | current | Line Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indicat… |
| 1.3.6.1.4.1.20044.68.2.3.2.120.1.9 | Columnpmlma10AlmLineTempHighWngPortn | read-only | current | Line Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning indic… |
| 1.3.6.1.4.1.20044.68.2.3.2.120.1.16 | Columnpmlma10AlmLineRxPwrLowWngPortn | read-only | current | Line Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning ind… |
| 1.3.6.1.4.1.20044.68.2.3.2.120.1.17 | Columnpmlma10AlmLineRxPwrHighWngPortn | read-only | current | Line Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning i… |
| 1.3.6.1.4.1.20044.68.2.3.2.152 | Tablepmlma10AlmlineHostLaneFaultTable | not-accessible | current | List of pmlma10AlmlineHostLaneFault Article |
| 1.3.6.1.4.1.20044.68.2.3.2.152.1 | Rowpmlma10AlmlineHostLaneFaultEntry | not-accessible | current | Row definition for the pmlma10AlmlineHostLaneFault table |
| 1.3.6.1.4.1.20044.68.2.3.2.152.1.1 | Columnpmlma10AlmlineHostLaneFaultIndex | read-only | current | Index definition for the pmlma10AlmlineHostLaneFault table |
| 1.3.6.1.4.1.20044.68.2.3.2.152.1.2 | Columnpmlma10AlmLineInputLossOfSignalPortn | read-only | current | Line Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Line Trscv <Help> Alarm indicating a Loss of Signal is detected on the Line T… |
| 1.3.6.1.4.1.20044.68.2.3.2.152.1.3 | Columnpmlma10AlmLineLossOfFramePortn | read-only | current | Line Loss Of Frame :This OID indicates the module is not aligned with the incoming Line signal <Help> Alarm indicating the module is not aligned with the incom… |
| 1.3.6.1.4.1.20044.68.2.3.2.152.1.4 | Columnpmlma10AlmLineSmBdiInsertedPortn | read-only | current | Line SM BDI Inserted :This OID indicates a SM Backward Defect Indication is inserted on the outgoing Line signal <Help> Status indicating a SM Backward Defect … |
| 1.3.6.1.4.1.20044.68.2.3.2.152.1.5 | Columnpmlma10AlmLineSmBdiDetectedPortn | read-only | current | Line SM BDI Detected :This OID indicates a SM Backward Defect Indication is detected on the incoming Line signal <Help> Alarm indicating a SM Backward Defect I… |
| 1.3.6.1.4.1.20044.68.2.3.3 | Nodepmlma10AlmLineCrit | |||
| 1.3.6.1.4.1.20044.68.2.3.3.24 | Tablepmlma10AlmsynthAlmLineTable | not-accessible | current | List of pmlma10AlmsynthAlmLine Article |
| 1.3.6.1.4.1.20044.68.2.3.3.24.1 | Rowpmlma10AlmsynthAlmLineEntry | not-accessible | current | Row definition for the pmlma10AlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.68.2.3.3.24.1.1 | Columnpmlma10AlmsynthAlmLineIndex | read-only | current | Index definition for the pmlma10AlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.68.2.3.3.24.1.2 | Columnpmlma10AlmLineSfpAbsentPortn | read-only | current | Line Optical Module Absent :This OID indicates that the line optical interface is not present. <Help> This alarm indicates if the line transceiver is not plugg… |
| 1.3.6.1.4.1.20044.68.2.3.3.24.1.3 | Columnpmlma10AlmLineDdmAbsentPortn | read-only | current | Line Optical Module Ready :This OID indicates that the optical interface is not operational. <Help> This status indicates if the line transceiver has been corr… |
| 1.3.6.1.4.1.20044.68.2.3.3.24.1.5 | Columnpmlma10AlmLineHwFailPortn | read-only | current | Line Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Help> This alarm indicates a failure on line port, most pr… |
| 1.3.6.1.4.1.20044.68.2.3.3.24.1.6 | Columnpmlma10AlmLineTxOffPortn | read-only | current | Line Trscv Laser Shutdown :This OID indicates the Line transceiver laser is shutdown <Help> This status indicates if the Line transceiver laser is shutdown <Co… |
| 1.3.6.1.4.1.20044.68.2.3.3.24.1.7 | Columnpmlma10AlmLineLocalOosPortn | read-only | current | Line Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service… |
| 1.3.6.1.4.1.20044.68.2.3.3.24.1.9 | Columnpmlma10AlmUpRdiInsPortn | read-only | current | MS-RDI/L-RDI Inserted On Line :This OID indicates an upstream MS-RDI/L-RDI has been inserted in the outgoing 10 Gb/s SDH/SONET signal. <Help> This status indic… |
| 1.3.6.1.4.1.20044.68.2.3.3.24.1.10 | Columnpmlma10AlmLineDdmWarningPortn | read-only | current | Warning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Warning has… |
| 1.3.6.1.4.1.20044.68.2.3.3.24.1.11 | Columnpmlma10AlmLineDdmAlmPortn | read-only | current | Alarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Alarm has been… |
| 1.3.6.1.4.1.20044.68.2.3.3.24.1.13 | Columnpmlma10AlmLineFailPortn | read-only | current | Line Port Failure :This OID indicates a failure on the line port <Help> This alarm indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipm… |
| 1.3.6.1.4.1.20044.68.3 | Nodepmlma10measures | |||
| 1.3.6.1.4.1.20044.68.3.1 | Nodepmlma10MesrOther | |||
| 1.3.6.1.4.1.20044.68.3.2 | Nodepmlma10MesrClient | |||
| 1.3.6.1.4.1.20044.68.3.2.16 | Tablepmlma10MesrclientTempTable | not-accessible | current | List of pmlma10MesrclientTemp Article |
| 1.3.6.1.4.1.20044.68.3.2.16.1 | Rowpmlma10MesrclientTempEntry | not-accessible | current | Row definition for the pmlma10MesrclientTemp table |
| 1.3.6.1.4.1.20044.68.3.2.16.1.1 | Columnpmlma10MesrclientTempIndex | read-only | current | Index definition for the pmlma10MesrclientTemp table |
| 1.3.6.1.4.1.20044.68.3.2.16.1.2 | Columnpmlma10MesrclientTempPortn | read-only | current | Client Optical Module Temperature :This OID gives the Laser temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Tem… |
| 1.3.6.1.4.1.20044.68.3.2.32 | Tablepmlma10MesrclientTxBiasTable | not-accessible | current | List of pmlma10MesrclientTxBias Article |
| 1.3.6.1.4.1.20044.68.3.2.32.1 | Rowpmlma10MesrclientTxBiasEntry | not-accessible | current | Row definition for the pmlma10MesrclientTxBias table |
| 1.3.6.1.4.1.20044.68.3.2.32.1.1 | Columnpmlma10MesrclientTxBiasIndex | read-only | current | Index definition for the pmlma10MesrclientTxBias table |
| 1.3.6.1.4.1.20044.68.3.2.32.1.2 | Columnpmlma10MesrclientTxBiasPortn | read-only | current | Client Optical Module Bias :This OID gives the Laser bias value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (U… |
| 1.3.6.1.4.1.20044.68.3.2.48 | Tablepmlma10MesrclientTxPwrTable | not-accessible | current | List of pmlma10MesrclientTxPwr Article |
| 1.3.6.1.4.1.20044.68.3.2.48.1 | Rowpmlma10MesrclientTxPwrEntry | not-accessible | current | Row definition for the pmlma10MesrclientTxPwr table |
| 1.3.6.1.4.1.20044.68.3.2.48.1.1 | Columnpmlma10MesrclientTxPwrIndex | read-only | current | Index definition for the pmlma10MesrclientTxPwr table |
| 1.3.6.1.4.1.20044.68.3.2.48.1.2 | Columnpmlma10MesrclientTxPwrPortn | read-only | current | Client Optical Module Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 1… |
| 1.3.6.1.4.1.20044.68.3.2.64 | Tablepmlma10MesrclientRxPwrTable | not-accessible | current | List of pmlma10MesrclientRxPwr Article |
| 1.3.6.1.4.1.20044.68.3.2.64.1 | Rowpmlma10MesrclientRxPwrEntry | not-accessible | current | Row definition for the pmlma10MesrclientRxPwr table |
| 1.3.6.1.4.1.20044.68.3.2.64.1.1 | Columnpmlma10MesrclientRxPwrIndex | read-only | current | Index definition for the pmlma10MesrclientRxPwr table |
| 1.3.6.1.4.1.20044.68.3.2.64.1.2 | Columnpmlma10MesrclientRxPwrPortn | read-only | current | Client Optical Module Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*l… |
| 1.3.6.1.4.1.20044.68.3.3 | Nodepmlma10MesrLine | |||
| 1.3.6.1.4.1.20044.68.3.3.80 | Tablepmlma10MesrlineTxPwrTable | not-accessible | current | List of pmlma10MesrlineTxPwr Article |
| 1.3.6.1.4.1.20044.68.3.3.80.1 | Rowpmlma10MesrlineTxPwrEntry | not-accessible | current | Row definition for the pmlma10MesrlineTxPwr table |
| 1.3.6.1.4.1.20044.68.3.3.80.1.1 | Columnpmlma10MesrlineTxPwrIndex | read-only | current | Index definition for the pmlma10MesrlineTxPwr table |
| 1.3.6.1.4.1.20044.68.3.3.80.1.2 | Columnpmlma10MesrlineTxPwrPortn | read-only | current | Line Optical Module Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power … |
| 1.3.6.1.4.1.20044.68.3.3.96 | Tablepmlma10MesrlineTempTable | not-accessible | current | List of pmlma10MesrlineTemp Article |
| 1.3.6.1.4.1.20044.68.3.3.96.1 | Rowpmlma10MesrlineTempEntry | not-accessible | current | Row definition for the pmlma10MesrlineTemp table |
| 1.3.6.1.4.1.20044.68.3.3.96.1.1 | Columnpmlma10MesrlineTempIndex | read-only | current | Index definition for the pmlma10MesrlineTemp table |
| 1.3.6.1.4.1.20044.68.3.3.96.1.2 | Columnpmlma10MesrlineTempPortn | read-only | current | Line Optical Module Temperature :This OID gives the Tx Laser Temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temp… |
| 1.3.6.1.4.1.20044.68.3.3.112 | Tablepmlma10MesrlineTxBiasTable | not-accessible | current | List of pmlma10MesrlineTxBias Article |
| 1.3.6.1.4.1.20044.68.3.3.112.1 | Rowpmlma10MesrlineTxBiasEntry | not-accessible | current | Row definition for the pmlma10MesrlineTxBias table |
| 1.3.6.1.4.1.20044.68.3.3.112.1.1 | Columnpmlma10MesrlineTxBiasIndex | read-only | current | Index definition for the pmlma10MesrlineTxBias table |
| 1.3.6.1.4.1.20044.68.3.3.112.1.2 | Columnpmlma10MesrlineTxBiasPortn | read-only | current | Line Optical Module Laser Bias :This OID gives the Tx Laser Bias value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/50… |
| 1.3.6.1.4.1.20044.68.3.3.128 | Tablepmlma10MesrlineRxPwrTable | not-accessible | current | List of pmlma10MesrlineRxPwr Article |
| 1.3.6.1.4.1.20044.68.3.3.128.1 | Rowpmlma10MesrlineRxPwrEntry | not-accessible | current | Row definition for the pmlma10MesrlineRxPwr table |
| 1.3.6.1.4.1.20044.68.3.3.128.1.1 | Columnpmlma10MesrlineRxPwrIndex | read-only | current | Index definition for the pmlma10MesrlineRxPwr table |
| 1.3.6.1.4.1.20044.68.3.3.128.1.2 | Columnpmlma10MesrlineRxPwrPortn | read-only | current | Line Optical Module Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(A… |
| 1.3.6.1.4.1.20044.68.4 | Nodepmlma10counters | |||
| 1.3.6.1.4.1.20044.68.4.1 | Nodepmlma10CntOther | |||
| 1.3.6.1.4.1.20044.68.4.2 | Nodepmlma10CntClient | |||
| 1.3.6.1.4.1.20044.68.4.2.96 | Tablepmlma10CntclientCbipCounterTable | not-accessible | current | List of pmlma10CntclientCbipCounter Article |
| 1.3.6.1.4.1.20044.68.4.2.96.1 | Rowpmlma10CntclientCbipCounterEntry | not-accessible | current | Row definition for the pmlma10CntclientCbipCounter table |
| 1.3.6.1.4.1.20044.68.4.2.96.1.1 | Columnpmlma10CntclientCbipCounterIndex | read-only | current | Index definition for the pmlma10CntclientCbipCounter table |
| 1.3.6.1.4.1.20044.68.4.2.96.1.2 | Columnpmlma10CntclientCbipCounterValuePortn | read-only | current | Client Output Errors :This counter is incremented each time a CBIP parity error is detected on the Client output stream <Help> This counter gives the number of… |
| 1.3.6.1.4.1.20044.68.4.2.96.1.3 | Columnpmlma10CntclientCbipCounterErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the CBIP error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.68.4.2.96.1.4 | Columnpmlma10CntclientCbipCounterOverloadPortn | read-only | current | Client CBIP Counter Overload :This OID when set indicates a CBIP error counter overload on Port |
| 1.3.6.1.4.1.20044.68.4.3 | Nodepmlma10CntLine | |||
| 1.3.6.1.4.1.20044.68.4.3.192 | Tablepmlma10CntlocalLineSmBip8ErrorCounterTable | not-accessible | current | List of pmlma10CntlocalLineSmBip8ErrorCounter Article |
| 1.3.6.1.4.1.20044.68.4.3.192.1 | Rowpmlma10CntlocalLineSmBip8ErrorCounterEntry | not-accessible | current | Row definition for the pmlma10CntlocalLineSmBip8ErrorCounter table |
| 1.3.6.1.4.1.20044.68.4.3.192.1.1 | Columnpmlma10CntlocalLineSmBip8ErrorCounterIndex | read-only | current | Index definition for the pmlma10CntlocalLineSmBip8ErrorCounter table |
| 1.3.6.1.4.1.20044.68.4.3.192.1.2 | Columnpmlma10CntlocalLineSmBip8ErrorCounterValuePortn | read-only | current | Line Input SM-BIP8 Errors :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC <Help> This counter gives the current Bit Error Rate (r… |
| 1.3.6.1.4.1.20044.68.4.3.192.1.3 | Columnpmlma10CntlocalLineSmBip8ErrorCounterErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the B1 error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.68.4.3.192.1.4 | Columnpmlma10CntlocalLineSmBip8ErrorCounterOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a B1 error counter overload on Port |
| 1.3.6.1.4.1.20044.68.4.3.200 | Tablepmlma10CntlocalLineFecCorrectedErrorsCounterTable | not-accessible | current | List of pmlma10CntlocalLineFecCorrectedErrorsCounter Article |
| 1.3.6.1.4.1.20044.68.4.3.200.1 | Rowpmlma10CntlocalLineFecCorrectedErrorsCounterEntry | not-accessible | current | Row definition for the pmlma10CntlocalLineFecCorrectedErrorsCounter table |
| 1.3.6.1.4.1.20044.68.4.3.200.1.1 | Columnpmlma10CntlocalLineFecCorrectedErrorsCounterIndex | read-only | current | Index definition for the pmlma10CntlocalLineFecCorrectedErrorsCounter table |
| 1.3.6.1.4.1.20044.68.4.3.200.1.2 | Columnpmlma10CntlocalLineFecCorrectedErrorsCounterValuePortn | read-only | current | Line Input HD FEC Corrected Errors :This OID gives the current Bit Error Rate before the Hard Decision FEC <Help> This counter gives the current Bit Error Rate… |
| 1.3.6.1.4.1.20044.68.4.3.200.1.3 | Columnpmlma10CntlocalLineFecCorrectedErrorsCounterErrorPortn | read-only | current | FEC Counter Error :This bit when set indicates the FEC corrected errors counter value is invalid on Line |
| 1.3.6.1.4.1.20044.68.4.3.200.1.4 | Columnpmlma10CntlocalLineFecCorrectedErrorsCounterOverloadPortn | read-only | current | FEC Counter Overload :This bit when set indicates a FEC corrected errors counter overload on Line |
| 1.3.6.1.4.1.20044.68.4.3.208 | Tablepmlma10CntremoteLineSmBip8ErrorCounterTable | not-accessible | current | List of pmlma10CntremoteLineSmBip8ErrorCounter Article |
| 1.3.6.1.4.1.20044.68.4.3.208.1 | Rowpmlma10CntremoteLineSmBip8ErrorCounterEntry | not-accessible | current | Row definition for the pmlma10CntremoteLineSmBip8ErrorCounter table |
| 1.3.6.1.4.1.20044.68.4.3.208.1.1 | Columnpmlma10CntremoteLineSmBip8ErrorCounterIndex | read-only | current | Index definition for the pmlma10CntremoteLineSmBip8ErrorCounter table |
| 1.3.6.1.4.1.20044.68.4.3.208.1.2 | Columnpmlma10CntremoteLineSmBip8ErrorCounterValuePortn | read-only | current | Remote SM BIP8 :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC on the remote side <Help> This counter gives the current Bit Error… |
| 1.3.6.1.4.1.20044.68.4.3.208.1.3 | Columnpmlma10CntremoteLineSmBip8ErrorCounterErrorPortn | read-only | current | Remote Counter Error : |
| 1.3.6.1.4.1.20044.68.4.3.208.1.4 | Columnpmlma10CntremoteLineSmBip8ErrorCounterOverloadPortn | read-only | current | Remote Counter Overload : |
| 1.3.6.1.4.1.20044.68.4.3.216 | Tablepmlma10CntlineDfrmTimCntTable | not-accessible | current | List of pmlma10CntlineDfrmTimCnt Article |
| 1.3.6.1.4.1.20044.68.4.3.216.1 | Rowpmlma10CntlineDfrmTimCntEntry | not-accessible | current | Row definition for the pmlma10CntlineDfrmTimCnt table |
| 1.3.6.1.4.1.20044.68.4.3.216.1.1 | Columnpmlma10CntlineDfrmTimCntIndex | read-only | current | Index definition for the pmlma10CntlineDfrmTimCnt table |
| 1.3.6.1.4.1.20044.68.4.3.216.1.2 | Columnpmlma10CntlineDfrmTimCntValuePortn | read-only | current | Line Timer Counter : |
| 1.3.6.1.4.1.20044.68.4.3.216.1.3 | Columnpmlma10CntlineDfrmTimCntErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.68.4.3.216.1.4 | Columnpmlma10CntlineDfrmTimCntOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.68.4.259 | Scalarpmlma10CntCountersReset | read-write | current | Counters Reset:This OID resets and restarts all the counters |
| 1.3.6.1.4.1.20044.68.4.260 | Scalarpmlma10CntCountersStop | read-write | current | Counters stop:This OID stops all the counters |
| 1.3.6.1.4.1.20044.68.6 | Nodepmlma10controlsWrite | |||
| 1.3.6.1.4.1.20044.68.6.1 | Nodepmlma10CtrlOther | |||
| 1.3.6.1.4.1.20044.68.6.1.1 | Nodepmlma10CtrlconfMgnt1 | |||
| 1.3.6.1.4.1.20044.68.6.1.1.1 | Scalarpmlma10CtrlConf1Load1 | read-write | current | Load Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM. |
| 1.3.6.1.4.1.20044.68.6.1.1.2 | Scalarpmlma10CtrlConf2Load1 | read-write | current | Load Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM. |
| 1.3.6.1.4.1.20044.68.6.1.1.10 | Scalarpmlma10CtrlConf2Flash1 | read-write | current | Write Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura… |
| 1.3.6.1.4.1.20044.68.6.1.1.14 | Scalarpmlma10CtrlConf2Clear1 | read-write | current | Clear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o… |
| 1.3.6.1.4.1.20044.68.6.1.4 | Nodepmlma10Ctrlsynth4 | |||
| 1.3.6.1.4.1.20044.68.6.1.4.1 | Scalarpmlma10CtrlCorrelatOn | read-write | current | Enable Alarm Correlation :This OID enables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.68.6.1.4.2 | Scalarpmlma10CtrlCorrelatOff | read-write | current | Disable Alarm Correlation :This OID disables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.68.6.1.5 | Nodepmlma10CtrlswMgnt | |||
| 1.3.6.1.4.1.20044.68.6.1.5.2 | Scalarpmlma10CtrlColdReset | read-write | current | PM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> … |
| 1.3.6.1.4.1.20044.68.6.1.5.3 | Scalarpmlma10CtrlWarmReset | read-write | current | PM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th… |
| 1.3.6.1.4.1.20044.68.6.1.5.5 | Scalarpmlma10CtrlLoadSwBank1 | read-write | current | Set Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW… |
| 1.3.6.1.4.1.20044.68.6.1.5.6 | Scalarpmlma10CtrlLoadSwBank2 | read-write | current | Set Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S… |
| 1.3.6.1.4.1.20044.68.6.1.6 | Nodepmlma10CtrlgwMgnt | |||
| 1.3.6.1.4.1.20044.68.6.1.6.1 | Scalarpmlma10CtrlCurrentGwReset | read-write | current | Active Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting. |
| 1.3.6.1.4.1.20044.68.6.1.6.5 | Scalarpmlma10CtrlLoadGwBank1 | read-write | current | Set Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.68.6.1.6.6 | Scalarpmlma10CtrlLoadGwBank2 | read-write | current | Set Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.68.6.1.6.7 | Scalarpmlma10CtrlLoadGwBank3 | read-write | current | Set Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.68.6.1.6.8 | Scalarpmlma10CtrlLoadGwBank4 | read-write | current | Set Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.68.6.1.192 | Nodepmlma10CtrlledTest | |||
| 1.3.6.1.4.1.20044.68.6.1.192.1 | Scalarpmlma10CtrlGreenLed | read-write | current | Green Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green |
| 1.3.6.1.4.1.20044.68.6.1.192.2 | Scalarpmlma10CtrlRedLed | read-write | current | Red Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red |
| 1.3.6.1.4.1.20044.68.6.1.192.3 | Scalarpmlma10CtrlLedOff | read-write | current | Leds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF |
| 1.3.6.1.4.1.20044.68.6.2 | Nodepmlma10CtrlClient | |||
| 1.3.6.1.4.1.20044.68.6.2.16 | Tablepmlma10CtrlaccessLoopTable | not-accessible | current | List of pmlma10CtrlaccessLoop Article |
| 1.3.6.1.4.1.20044.68.6.2.16.1 | Rowpmlma10CtrlaccessLoopEntry | not-accessible | current | Row definition for the pmlma10CtrlaccessLoop table |
| 1.3.6.1.4.1.20044.68.6.2.16.1.1 | Columnpmlma10CtrlaccessLoopIndex | read-only | current | Index definition for the pmlma10CtrlaccessLoop table |
| 1.3.6.1.4.1.20044.68.6.2.16.1.2 | Columnpmlma10CtrlaccessLoopPortn | read-write | current | Client Facility Loopback :This OID, when set at '1' puts the client port in loopback, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. <Help… |
| 1.3.6.1.4.1.20044.68.6.2.17 | Tablepmlma10CtrlclientLoopToLineTable | not-accessible | current | List of pmlma10CtrlclientLoopToLine Article |
| 1.3.6.1.4.1.20044.68.6.2.17.1 | Rowpmlma10CtrlclientLoopToLineEntry | not-accessible | current | Row definition for the pmlma10CtrlclientLoopToLine table |
| 1.3.6.1.4.1.20044.68.6.2.17.1.1 | Columnpmlma10CtrlclientLoopToLineIndex | read-only | current | Index definition for the pmlma10CtrlclientLoopToLine table |
| 1.3.6.1.4.1.20044.68.6.2.17.1.2 | Columnpmlma10CtrlclientLoopToLinePortn | read-write | current | Client Terminal Loopback :This OID, when set, puts the client port in loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.<Help> This control ena… |
| 1.3.6.1.4.1.20044.68.6.2.21 | Tablepmlma10CtrlcsfUpInsTable | not-accessible | current | List of pmlma10CtrlcsfUpIns Article |
| 1.3.6.1.4.1.20044.68.6.2.21.1 | Rowpmlma10CtrlcsfUpInsEntry | not-accessible | current | Row definition for the pmlma10CtrlcsfUpIns table |
| 1.3.6.1.4.1.20044.68.6.2.21.1.1 | Columnpmlma10CtrlcsfUpInsIndex | read-only | current | Index definition for the pmlma10CtrlcsfUpIns table |
| 1.3.6.1.4.1.20044.68.6.2.21.1.2 | Columnpmlma10CtrlcsfUpInsPortn | read-write | current | Client Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo… |
| 1.3.6.1.4.1.20044.68.6.2.22 | Tablepmlma10CtrlcaisDwInsTable | not-accessible | current | List of pmlma10CtrlcaisDwIns Article |
| 1.3.6.1.4.1.20044.68.6.2.22.1 | Rowpmlma10CtrlcaisDwInsEntry | not-accessible | current | Row definition for the pmlma10CtrlcaisDwIns table |
| 1.3.6.1.4.1.20044.68.6.2.22.1.1 | Columnpmlma10CtrlcaisDwInsIndex | read-only | current | Index definition for the pmlma10CtrlcaisDwIns table |
| 1.3.6.1.4.1.20044.68.6.2.22.1.2 | Columnpmlma10CtrlcaisDwInsPortn | read-write | current | Client AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port |
| 1.3.6.1.4.1.20044.68.6.3 | Nodepmlma10CtrlLine | |||
| 1.3.6.1.4.1.20044.68.6.3.64 | Tablepmlma10CtrlcommAccessLoopTable | not-accessible | current | List of pmlma10CtrlcommAccessLoop Article |
| 1.3.6.1.4.1.20044.68.6.3.64.1 | Rowpmlma10CtrlcommAccessLoopEntry | not-accessible | current | Row definition for the pmlma10CtrlcommAccessLoop table |
| 1.3.6.1.4.1.20044.68.6.3.64.1.1 | Columnpmlma10CtrlcommAccessLoopIndex | read-only | current | Index definition for the pmlma10CtrlcommAccessLoop table |
| 1.3.6.1.4.1.20044.68.6.3.64.1.2 | Columnpmlma10CtrlcommAccessLoopPortn | read-write | current | Line Terminal Loopback :This OID, when set, puts the module in common access loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.<Help> This cont… |
| 1.3.6.1.4.1.20044.68.6.3.66 | Tablepmlma10CtrllineLoopTable | not-accessible | current | List of pmlma10CtrllineLoop Article |
| 1.3.6.1.4.1.20044.68.6.3.66.1 | Rowpmlma10CtrllineLoopEntry | not-accessible | current | Row definition for the pmlma10CtrllineLoop table |
| 1.3.6.1.4.1.20044.68.6.3.66.1.1 | Columnpmlma10CtrllineLoopIndex | read-only | current | Index definition for the pmlma10CtrllineLoop table |
| 1.3.6.1.4.1.20044.68.6.3.66.1.2 | Columnpmlma10CtrllineLoopPortn | read-write | current | Line Facility Loopback :This OID, when set at '1' puts the module in line loopback mode, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. Th… |
| 1.3.6.1.4.1.20044.68.6.3.69 | Tablepmlma10CtrlfecDisableTable | not-accessible | current | List of pmlma10CtrlfecDisable Article |
| 1.3.6.1.4.1.20044.68.6.3.69.1 | Rowpmlma10CtrlfecDisableEntry | not-accessible | current | Row definition for the pmlma10CtrlfecDisable table |
| 1.3.6.1.4.1.20044.68.6.3.69.1.1 | Columnpmlma10CtrlfecDisableIndex | read-only | current | Index definition for the pmlma10CtrlfecDisable table |
| 1.3.6.1.4.1.20044.68.6.3.69.1.2 | Columnpmlma10CtrlfecDisablePortn | read-write | current | Forward Error Correction Inhibition :This OID, when set, inhibits the Forward Error Correction feature on the line input <Help> This control enables/disables t… |
| 1.3.6.1.4.1.20044.68.7 | Nodepmlma10ri | |||
| 1.3.6.1.4.1.20044.68.7.1 | Nodepmlma10riTable | |||
| 1.3.6.1.4.1.20044.68.7.1.1 | Tablepmlma10RinvSfpTable | not-accessible | current | List of the SFPs on the selected module |
| 1.3.6.1.4.1.20044.68.7.1.1.1 | Rowpmlma10RinvSfpEntry | not-accessible | current | Row definition for the SFP table |
| 1.3.6.1.4.1.20044.68.7.1.1.1.1 | Columnpmlma10RinvSfpIndex | read-only | current | Index for SFP table |
| 1.3.6.1.4.1.20044.68.7.1.1.1.2 | Columnpmlma10Rinvsfp | read-only | current | Inventory for the SFP: This OID contains the inventory for the SFP |
| 1.3.6.1.4.1.20044.68.7.1.2 | Tablepmlma10RinvLineTable | not-accessible | current | List of the XFPs on the selected module |
| 1.3.6.1.4.1.20044.68.7.1.2.1 | Rowpmlma10RinvLineEntry | not-accessible | current | Row definition for the XFP table |
| 1.3.6.1.4.1.20044.68.7.1.2.1.1 | Columnpmlma10RinvLineIndex | read-only | current | Index for XFP table |
| 1.3.6.1.4.1.20044.68.7.1.2.1.2 | Columnpmlma10RinvxfpLine | read-only | current | Inventory for the XFP: This OID contains the inventory for the XFP |
| 1.3.6.1.4.1.20044.68.7.2 | Scalarpmlma10RinvReloadInventory | read-write | current | Reload the inventory: This OID triggers an inventory reload. |
| 1.3.6.1.4.1.20044.68.7.3 | Scalarpmlma10RinvHwPlatform | read-only | current | HW platform description: This OID contains the description of the Hardware platform. |
| 1.3.6.1.4.1.20044.68.7.4 | Scalarpmlma10RinvModulePlatform | read-only | current | Module platform description: This OID contains the description of the Module. |
| 1.3.6.1.4.1.20044.68.7.5 | Scalarpmlma10RinvSwPlatform | read-only | current | SW platform description: This OID contains the description of the Software platform. |
| 1.3.6.1.4.1.20044.68.7.6 | Scalarpmlma10RinvGwPlatform | read-only | current | GW platform description: This OID contains the description of the Gateware platform. |
| 1.3.6.1.4.1.20044.68.8 | Nodepmlma10download | |||
| 1.3.6.1.4.1.20044.68.8.1 | Nodepmlma10DwlOther | |||
| 1.3.6.1.4.1.20044.68.8.1.0 | Nodepmlma10DwlrestartProcess | |||
| 1.3.6.1.4.1.20044.68.8.1.0.1 | Scalarpmlma10DwlWarmRestartProcessed | read-only | current | Warm Restart :This OID indicates that the module last restart was a Warm RESTART |
| 1.3.6.1.4.1.20044.68.8.1.0.2 | Scalarpmlma10DwlColdRestartProcessed | read-only | current | Cold Restart :This OID indicates that the module last restart was a Cold RESTART |
| 1.3.6.1.4.1.20044.68.8.1.1 | Nodepmlma10DwlswBanksUsed | |||
| 1.3.6.1.4.1.20044.68.8.1.1.1 | Scalarpmlma10DwlSwBank1Used | read-only | current | SW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.68.8.1.1.2 | Scalarpmlma10DwlSwBank2Used | read-only | current | SW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby |
| 1.3.6.1.4.1.20044.68.8.1.1.5 | Scalarpmlma10DwlSwBank1Notempty | read-only | current | SW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package |
| 1.3.6.1.4.1.20044.68.8.1.1.6 | Scalarpmlma10DwlSwBank2Notempty | read-only | current | SW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package |
| 1.3.6.1.4.1.20044.68.8.1.2 | Nodepmlma10DwlgwBanksUsed | |||
| 1.3.6.1.4.1.20044.68.8.1.2.1 | Scalarpmlma10DwlGwBank1Used | read-only | current | GW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.68.8.1.2.2 | Scalarpmlma10DwlGwBank2Used | read-only | current | GW bank 2 active :This OID indicates the module is working on GW bank 2 |
| 1.3.6.1.4.1.20044.68.8.1.2.3 | Scalarpmlma10DwlGwBank3Used | read-only | current | GW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby |
| 1.3.6.1.4.1.20044.68.8.1.2.4 | Scalarpmlma10DwlGwBank4Used | read-only | current | GW bank 4 active :This OID indicates the module is working on GW bank 4 |
| 1.3.6.1.4.1.20044.68.8.1.2.5 | Scalarpmlma10DwlGwBank1Notempty | read-only | current | GW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package |
| 1.3.6.1.4.1.20044.68.8.1.2.6 | Scalarpmlma10DwlGwBank2Notempty | read-only | current | GW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2 |
| 1.3.6.1.4.1.20044.68.8.1.2.7 | Scalarpmlma10DwlGwBank3Notempty | read-only | current | GW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package |
| 1.3.6.1.4.1.20044.68.8.1.2.8 | Scalarpmlma10DwlGwBank4Notempty | read-only | current | GW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4 |
| 1.3.6.1.4.1.20044.68.8.2 | Nodepmlma10DwlClient | |||
| 1.3.6.1.4.1.20044.68.8.3 | Nodepmlma10DwlLine | |||
| 1.3.6.1.4.1.20044.68.9 | Nodepmlma10Config | |||
| 1.3.6.1.4.1.20044.68.9.1 | Nodepmlma10CfgAccessCAisCsf | |||
| 1.3.6.1.4.1.20044.68.9.1.1 | Tablepmlma10CfgClientcaiscsfTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.68.9.1.1.1 | Rowpmlma10CfgClientcaiscsfEntry | not-accessible | current | Row definition for the accessCAisCsf table |
| 1.3.6.1.4.1.20044.68.9.1.1.1.1 | Columnpmlma10CfgClientcaiscsfIndex | read-only | current | Index definition for the clientcaiscsf table |
| 1.3.6.1.4.1.20044.68.9.1.1.1.3 | Columnpmlma10CfgReservePortn | read-write | current | CAIS mode on Client Port :This register enables/disables port laser shutdown on CAIS insertion condition |
| 1.3.6.1.4.1.20044.68.9.2 | Nodepmlma10CfgStartup | |||
| 1.3.6.1.4.1.20044.68.9.2.1 | Tablepmlma10CfgClientStartupTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.68.9.2.1.1 | Rowpmlma10CfgClientStartupEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.68.9.2.1.1.1 | Columnpmlma10CfgClientStartupIndex | read-only | current | Index definition for the clientStartup table |
| 1.3.6.1.4.1.20044.68.9.2.1.1.3 | Columnpmlma10CfgSystConfPortPortn | read-write | current | Default Settings on Client Port :This register configures the default initialisation settings on the port. |
| 1.3.6.1.4.1.20044.68.9.2.1.1.4 | Columnpmlma10CfgNetConfPortPortn | read-write | current | Default Settings on Client Port :This register configures the default initialisation settings on the port. |
| 1.3.6.1.4.1.20044.68.9.2.1.1.14 | Columnpmlma10CfgOptionsPortPortn | read-write | current | Default Options on Client Port :This register configures the default options on the port. |
| 1.3.6.1.4.1.20044.68.9.2.2 | Tablepmlma10CfgLinexr1StartupTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.68.9.2.2.1 | Rowpmlma10CfgLinexr1StartupEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.68.9.2.2.1.1 | Columnpmlma10CfgLinexr1StartupIndex | read-only | current | Index definition for the linexr1Startup table |
| 1.3.6.1.4.1.20044.68.9.2.2.1.3 | Columnpmlma10CfgSystConfLinePortn | read-write | current | Default Settings on Line :This register configures the default initialisation settings on Line |
| 1.3.6.1.4.1.20044.68.9.2.2.1.14 | Columnpmlma10CfgOptionsLinePortn | read-write | current | Default Options on Line :This register configures the default options on the line |
| 1.3.6.1.4.1.20044.68.9.2.3 | Tablepmlma10CfgEmptyTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.68.9.2.3.1 | Rowpmlma10CfgEmptyEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.68.9.2.3.1.1 | Columnpmlma10CfgEmptyIndex | read-only | current | Index definition for the empty table |
| 1.3.6.1.4.1.20044.68.9.2.3.1.3 | Columnpmlma10CfgSystConfMsaLinePortn | read-write | current | Default settings on MSA :This register configures the default initialisation settings on MSA |
| 1.3.6.1.4.1.20044.68.9.3 | Nodepmlma10CfgLabels | |||
| 1.3.6.1.4.1.20044.68.9.3.1 | Tablepmlma10CfgLabelclientTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.68.9.3.1.1 | Rowpmlma10CfgLabelclientEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.68.9.3.1.1.1 | Columnpmlma10CfgLabelclientIndex | read-only | current | Index definition for the labelclient table |
| 1.3.6.1.4.1.20044.68.9.3.1.1.3 | Columnpmlma10CfgLabelclientPortn | read-write | current | Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. |
| 1.3.6.1.4.1.20044.68.9.3.2 | Tablepmlma10CfgLabellineTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.68.9.3.2.1 | Rowpmlma10CfgLabellineEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.68.9.3.2.1.1 | Columnpmlma10CfgLabellineIndex | read-only | current | Index definition for the labelline table |
| 1.3.6.1.4.1.20044.68.9.3.2.1.3 | Columnpmlma10CfgLabellinePortn | read-write | current | Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. |
| 1.3.6.1.4.1.20044.68.9.4 | Nodepmlma10CfgStartuptlh | |||
| 1.3.6.1.4.1.20044.68.9.4.1 | Tablepmlma10CfgOtxtlhTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.68.9.4.1.1 | Rowpmlma10CfgOtxtlhEntry | not-accessible | current | Row definition for the startuptlh table |
| 1.3.6.1.4.1.20044.68.9.4.1.1.1 | Columnpmlma10CfgOtxtlhIndex | read-only | current | Index definition for the otxtlh table |
| 1.3.6.1.4.1.20044.68.9.4.1.1.6 | Columnpmlma10CfgLinePwrLaserPortn | read-write | current | Defaut Line output Power :This register configures the start-up output power of the Line tranceiver (Unit = dBm) |
| 1.3.6.1.4.1.20044.68.9.4.1.1.7 | Columnpmlma10CfgLineFCurrentPortn | read-write | current | Default Line transceiver Tx Channel :This register configures the start-up laser channel of the Line Tx transceiver |
| 1.3.6.1.4.1.20044.68.9.4.1.1.8 | Columnpmlma10CfgLineGridCurrentPortn | read-write | current | Default Line transceiver Grid :This register configures the start-up laser grid of the Line transceiver |
| 1.3.6.1.4.1.20044.68.9.4.1.1.9 | Columnpmlma10CfgFPortn | read-write | current | Default Line TRX lowest Freq :This register configures the start-up lowest frequency of the Line transceiver |
| 1.3.6.1.4.1.20044.68.9.4.1.1.10 | Columnpmlma10CfgRxLineFCurrentPortn | read-write | current | Default Line transceiver Rx Channel :This register configures the start-up laser channel of the Line Rx transceiver |
| 1.3.6.1.4.1.20044.68.9.5 | Nodepmlma10CfgOther | |||
| 1.3.6.1.4.1.20044.68.9.5.1 | Nodepmlma10tablemoduleOther | |||
| 1.3.6.1.4.1.20044.68.9.5.1.2 | Scalarpmlma10Cfgmode | read-write | current | Default settings on Module :This register selects the configuration mode of the module |
| 1.3.6.1.4.1.20044.68.9.6 | Nodepmlma10CfgStartuptablefive | |||
| 1.3.6.1.4.1.20044.68.9.6.1 | Tablepmlma10CfgOtxtlhcapabilitiesTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.68.9.6.1.1 | Rowpmlma10CfgOtxtlhcapabilitiesEntry | not-accessible | current | Row definition for the startuptablefive table |
| 1.3.6.1.4.1.20044.68.9.6.1.1.1 | Columnpmlma10CfgOtxtlhcapabilitiesIndex | read-only | current | Index definition for the otxtlhcapabilities table |
| 1.3.6.1.4.1.20044.68.9.6.1.1.3 | Columnpmlma10CfgComponentTypePortn | read-only | current | Component parameters :This OID defines the component parameters |
| 1.3.6.1.4.1.20044.68.9.6.1.1.4 | Columnpmlma10CfgMiscellaneousPortn | read-only | current | Miscellaneous default settings :This OID defines the miscellaneous parameters |
| 1.3.6.1.4.1.20044.68.9.6.1.1.5 | Columnpmlma10CfgFirstChannelPortn | read-only | current | Number of the first channel of the component :This OID defines the first channel number of the PM |
| 1.3.6.1.4.1.20044.68.9.6.1.1.6 | Columnpmlma10CfgLastChannelPortn | read-only | current | Number of the last channel of the component :This OID defines the last channel number of the PM |
| 1.3.6.1.4.1.20044.68.9.6.1.1.7 | Columnpmlma10CfgGridPortn | read-only | current | Grid value of the component :This OID defines the grid of the PM |
| 1.3.6.1.4.1.20044.68.9.257 | Scalarpmlma10CfgWriteConfiguration | read-write | current | Write configuration to module:This OID writes the complete configuration to the module |
| 1.3.6.1.4.1.20044.68.10 | Nodepmlma10traps | |||
| 1.3.6.1.4.1.20044.68.10.2 | Scalarpmlma10trapPortNumber | read-only | current | Last port which generates a trap |
| 1.3.6.1.4.1.20044.68.10.3 | Scalarpmlma10trapLineNumber | read-only | current | Last Line which generates a trap |
| 1.3.6.1.4.1.20044.68.10.4 | Scalarpmlma10trapBoardNumber | read-only | current | Last module which generates a trap |
| 1.3.6.1.4.1.20044.68.10.30 | Notificationpmlma10LineTrapNotUrgentGoesOn | current | Not urgent Line default is activated | |
| 1.3.6.1.4.1.20044.68.10.31 | Notificationpmlma10LineTrapNotUrgentGoesOff | current | Not urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.68.10.32 | Notificationpmlma10LineTrapUrgentGoesOn | current | Urgent Line default is activated | |
| 1.3.6.1.4.1.20044.68.10.33 | Notificationpmlma10LineTrapUrgentGoesOff | current | Urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.68.10.34 | Notificationpmlma10LineTrapCritGoesOn | current | Critical Line default is activated | |
| 1.3.6.1.4.1.20044.68.10.35 | Notificationpmlma10LineTrapCritGoesOff | current | Critical Line default disappeared | |
| 1.3.6.1.4.1.20044.68.10.40 | Notificationpmlma10ClientTrapNotUrgentGoesOn | current | Not urgent client default is activated | |
| 1.3.6.1.4.1.20044.68.10.41 | Notificationpmlma10ClientTrapNotUrgentGoesOff | current | Not urgent client default disappeared | |
| 1.3.6.1.4.1.20044.68.10.42 | Notificationpmlma10ClientTrapUrgentGoesOn | current | Urgent client default is activated | |
| 1.3.6.1.4.1.20044.68.10.43 | Notificationpmlma10ClientTrapUrgentGoesOff | current | Urgent client default disappeared | |
| 1.3.6.1.4.1.20044.68.10.44 | Notificationpmlma10ClientTrapCritGoesOn | current | Critical client default is activated | |
| 1.3.6.1.4.1.20044.68.10.45 | Notificationpmlma10ClientTrapCritGoesOff | current | Critical client default disappeared | |
| 1.3.6.1.4.1.20044.68.10.50 | Notificationpmlma10PowerTrapUrgentGoesOn | current | Urgent power supply default is activated | |
| 1.3.6.1.4.1.20044.68.10.51 | Notificationpmlma10PowerTrapUrgentGoesOff | current | Urgent power supply default disappeared | |
| 1.3.6.1.4.1.20044.68.11 | Nodepmlma10Monitoring | |||
| 1.3.6.1.4.1.20044.68.11.1 | Nodepmlma10MonOther | |||
| 1.3.6.1.4.1.20044.68.11.1.3 | Nodepmlma10MonRmon | |||
| 1.3.6.1.4.1.20044.68.11.1.3.359 | Scalarpmlma10MonCountersReset | read-write | current | RMON Counters Reset:This OID resets and restarts all the RMON counters |
| 1.3.6.1.4.1.20044.68.11.1.3.360 | Scalarpmlma10MonCountersStop | read-write | current | RMON Counters stop:This OID stops all the RMON counters |
| 1.3.6.1.4.1.20044.68.11.2 | Nodepmlma10MonClient | |||
| 1.3.6.1.4.1.20044.68.11.2.4 | Nodepmlma10MonClientRmonCounter | |||
| 1.3.6.1.4.1.20044.68.11.2.4.16 | Tablepmlma10MonupRmonBytesCounterClientInputTable | not-accessible | current | List of pmlma10MonupRmonBytesCounterClientInput Article |
| 1.3.6.1.4.1.20044.68.11.2.4.16.1 | Rowpmlma10MonupRmonBytesCounterClientInputEntry | not-accessible | current | Row definition for the pmlma10MonupRmonBytesCounterClientInput table |
| 1.3.6.1.4.1.20044.68.11.2.4.16.1.1 | Columnpmlma10MonupRmonBytesCounterClientInputIndex | read-only | current | Index definition for the pmlma10MonupRmonBytesCounterClientInput table |
| 1.3.6.1.4.1.20044.68.11.2.4.16.1.2 | Columnpmlma10MonupRmonBytesCounterClientInputValuePortn | read-only | current | Client Input Bytes :This counter is increased each time a data byte is received on the client port <Help> This counter gives the number of bytes received on th… |
| 1.3.6.1.4.1.20044.68.11.2.4.16.1.3 | Columnpmlma10MonupRmonBytesCounterClientInputErrorPortn | read-only | current | Bytes Counter Error :This OID when set indicates the Bytes counter value is invalid on client port |
| 1.3.6.1.4.1.20044.68.11.2.4.16.1.4 | Columnpmlma10MonupRmonBytesCounterClientInputOverloadPortn | read-only | current | Bytes Counter Overload :This OID when set indicates a Bytes counter overload on client port |
| 1.3.6.1.4.1.20044.68.11.2.4.32 | Tablepmlma10MonupRmonCrcErrorsCounterClientInputTable | not-accessible | current | List of pmlma10MonupRmonCrcErrorsCounterClientInput Article |
| 1.3.6.1.4.1.20044.68.11.2.4.32.1 | Rowpmlma10MonupRmonCrcErrorsCounterClientInputEntry | not-accessible | current | Row definition for the pmlma10MonupRmonCrcErrorsCounterClientInput table |
| 1.3.6.1.4.1.20044.68.11.2.4.32.1.1 | Columnpmlma10MonupRmonCrcErrorsCounterClientInputIndex | read-only | current | Index definition for the pmlma10MonupRmonCrcErrorsCounterClientInput table |
| 1.3.6.1.4.1.20044.68.11.2.4.32.1.2 | Columnpmlma10MonupRmonCrcErrorsCounterClientInputValuePortn | read-only | current | Client Input B1/CRC Errors :This counter is increased each time a B1/FCS error is detected on the client port <Help> This counter gives the number of B1/FCS Er… |
| 1.3.6.1.4.1.20044.68.11.2.4.32.1.3 | Columnpmlma10MonupRmonCrcErrorsCounterClientInputErrorPortn | read-only | current | B1/FCS Errors Counter Error :This OID when set indicates the B1/FCS Errors counter value is invalid on client port |
| 1.3.6.1.4.1.20044.68.11.2.4.32.1.4 | Columnpmlma10MonupRmonCrcErrorsCounterClientInputOverloadPortn | read-only | current | B1/FCS Errors Counter Overload :This OID when set indicates a B1/FCS Errors counter overload on client port |
| 1.3.6.1.4.1.20044.68.11.2.4.48 | Tablepmlma10MonupRmonPacketsCounterClientInputTable | not-accessible | current | List of pmlma10MonupRmonPacketsCounterClientInput Article |
| 1.3.6.1.4.1.20044.68.11.2.4.48.1 | Rowpmlma10MonupRmonPacketsCounterClientInputEntry | not-accessible | current | Row definition for the pmlma10MonupRmonPacketsCounterClientInput table |
| 1.3.6.1.4.1.20044.68.11.2.4.48.1.1 | Columnpmlma10MonupRmonPacketsCounterClientInputIndex | read-only | current | Index definition for the pmlma10MonupRmonPacketsCounterClientInput table |
| 1.3.6.1.4.1.20044.68.11.2.4.48.1.2 | Columnpmlma10MonupRmonPacketsCounterClientInputValuePortn | read-only | current | Client Input Packets :This counter is increased each time a packet is received on the client port <Help> This counter gives the number of packets received on t… |
| 1.3.6.1.4.1.20044.68.11.2.4.48.1.3 | Columnpmlma10MonupRmonPacketsCounterClientInputErrorPortn | read-only | current | Packets Counter Error :This OID when set indicates the Packets counter value is invalid on client port |
| 1.3.6.1.4.1.20044.68.11.2.4.48.1.4 | Columnpmlma10MonupRmonPacketsCounterClientInputOverloadPortn | read-only | current | Packets Counter Overload :This OID when set indicates a Packets counter overload on client port |
| 1.3.6.1.4.1.20044.68.11.2.4.64 | Tablepmlma10MonupRmonBroadcastCounterClientInputTable | not-accessible | current | List of pmlma10MonupRmonBroadcastCounterClientInput Article |
| 1.3.6.1.4.1.20044.68.11.2.4.64.1 | Rowpmlma10MonupRmonBroadcastCounterClientInputEntry | not-accessible | current | Row definition for the pmlma10MonupRmonBroadcastCounterClientInput table |
| 1.3.6.1.4.1.20044.68.11.2.4.64.1.1 | Columnpmlma10MonupRmonBroadcastCounterClientInputIndex | read-only | current | Index definition for the pmlma10MonupRmonBroadcastCounterClientInput table |
| 1.3.6.1.4.1.20044.68.11.2.4.64.1.2 | Columnpmlma10MonupRmonBroadcastCounterClientInputValuePortn | read-only | current | Client Input Broadcast Packets :This counter is increased each time a broadcast packet is received on the client port <Help> This counter gives the number of B… |
| 1.3.6.1.4.1.20044.68.11.2.4.64.1.3 | Columnpmlma10MonupRmonBroadcastCounterClientInputErrorPortn | read-only | current | Broadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.68.11.2.4.64.1.4 | Columnpmlma10MonupRmonBroadcastCounterClientInputOverloadPortn | read-only | current | Broadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port |
| 1.3.6.1.4.1.20044.68.11.2.4.80 | Tablepmlma10MonupRmonMulticastCounterClientInputTable | not-accessible | current | List of pmlma10MonupRmonMulticastCounterClientInput Article |
| 1.3.6.1.4.1.20044.68.11.2.4.80.1 | Rowpmlma10MonupRmonMulticastCounterClientInputEntry | not-accessible | current | Row definition for the pmlma10MonupRmonMulticastCounterClientInput table |
| 1.3.6.1.4.1.20044.68.11.2.4.80.1.1 | Columnpmlma10MonupRmonMulticastCounterClientInputIndex | read-only | current | Index definition for the pmlma10MonupRmonMulticastCounterClientInput table |
| 1.3.6.1.4.1.20044.68.11.2.4.80.1.2 | Columnpmlma10MonupRmonMulticastCounterClientInputValuePortn | read-only | current | Client Input Multicast Packets :This counter is increased each time a Multicast packet is received on the client port <Help> This counter gives the number of M… |
| 1.3.6.1.4.1.20044.68.11.2.4.80.1.3 | Columnpmlma10MonupRmonMulticastCounterClientInputErrorPortn | read-only | current | Multicast Counter Error :This OID when set indicates the Multicast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.68.11.2.4.80.1.4 | Columnpmlma10MonupRmonMulticastCounterClientInputOverloadPortn | read-only | current | Multicast Counter Overload :This OID when set indicates a Multicast counter overload on client port |
| 1.3.6.1.4.1.20044.68.11.2.4.96 | Tablepmlma10MonupRmonPauseFrameCounterClientInputTable | not-accessible | current | List of pmlma10MonupRmonPauseFrameCounterClientInput Article |
| 1.3.6.1.4.1.20044.68.11.2.4.96.1 | Rowpmlma10MonupRmonPauseFrameCounterClientInputEntry | not-accessible | current | Row definition for the pmlma10MonupRmonPauseFrameCounterClientInput table |
| 1.3.6.1.4.1.20044.68.11.2.4.96.1.1 | Columnpmlma10MonupRmonPauseFrameCounterClientInputIndex | read-only | current | Index definition for the pmlma10MonupRmonPauseFrameCounterClientInput table |
| 1.3.6.1.4.1.20044.68.11.2.4.96.1.2 | Columnpmlma10MonupRmonPauseFrameCounterClientInputValuePortn | read-only | current | Client Input Pause Frames :This counter is increased each time a Pause frame is received on the client port <Help> This counter gives the number of Pause frame… |
| 1.3.6.1.4.1.20044.68.11.2.4.96.1.3 | Columnpmlma10MonupRmonPauseFrameCounterClientInputErrorPortn | read-only | current | Pause Counter Error :This OID when set indicates the Pause counter value is invalid on client port |
| 1.3.6.1.4.1.20044.68.11.2.4.96.1.4 | Columnpmlma10MonupRmonPauseFrameCounterClientInputOverloadPortn | read-only | current | Pause Counter Overload :This OID when set indicates a Pause counter overload on client port |
| 1.3.6.1.4.1.20044.68.11.2.4.224 | Tablepmlma10MondwRmonCrcErrorsCounterClientInputTable | not-accessible | current | List of pmlma10MondwRmonCrcErrorsCounterClientInput Article |
| 1.3.6.1.4.1.20044.68.11.2.4.224.1 | Rowpmlma10MondwRmonCrcErrorsCounterClientInputEntry | not-accessible | current | Row definition for the pmlma10MondwRmonCrcErrorsCounterClientInput table |
| 1.3.6.1.4.1.20044.68.11.2.4.224.1.1 | Columnpmlma10MondwRmonCrcErrorsCounterClientInputIndex | read-only | current | Index definition for the pmlma10MondwRmonCrcErrorsCounterClientInput table |
| 1.3.6.1.4.1.20044.68.11.2.4.224.1.2 | Columnpmlma10MondwRmonCrcErrorsCounterClientInputValuePortn | read-only | current | Client Output B1/CRC Errors :This counter is increased each time a B1/FCS error is detected on the output client port <Help> This counter gives the number of B… |
| 1.3.6.1.4.1.20044.68.11.2.4.224.1.3 | Columnpmlma10MondwRmonCrcErrorsCounterClientInputErrorPortn | read-only | current | Output B1/FCS Errors Counter Error :This OID when set indicates the output B1/FCS Errors counter value is invalid on client port |
| 1.3.6.1.4.1.20044.68.11.2.4.224.1.4 | Columnpmlma10MondwRmonCrcErrorsCounterClientInputOverloadPortn | read-only | current | Output B1/FCS Errors Counter Overload :This OID when set indicates an output B1/FCS Errors counter overload on client port |
| 1.3.6.1.4.1.20044.68.11.2.4.240 | Tablepmlma10MondwRmonPacketsCounterClientInputTable | not-accessible | current | List of pmlma10MondwRmonPacketsCounterClientInput Article |
| 1.3.6.1.4.1.20044.68.11.2.4.240.1 | Rowpmlma10MondwRmonPacketsCounterClientInputEntry | not-accessible | current | Row definition for the pmlma10MondwRmonPacketsCounterClientInput table |
| 1.3.6.1.4.1.20044.68.11.2.4.240.1.1 | Columnpmlma10MondwRmonPacketsCounterClientInputIndex | read-only | current | Index definition for the pmlma10MondwRmonPacketsCounterClientInput table |
| 1.3.6.1.4.1.20044.68.11.2.4.240.1.2 | Columnpmlma10MondwRmonPacketsCounterClientInputValuePortn | read-only | current | Client Output Packets :This counter is increased each time a packet is transmitted on the client port. <Help> This counter gives the number of packets detected… |
| 1.3.6.1.4.1.20044.68.11.2.4.240.1.3 | Columnpmlma10MondwRmonPacketsCounterClientInputErrorPortn | read-only | current | Output Packets Counter Error :This OID when set indicates the output Packets counter value is invalid on client port |
| 1.3.6.1.4.1.20044.68.11.2.4.240.1.4 | Columnpmlma10MondwRmonPacketsCounterClientInputOverloadPortn | read-only | current | Output Packets Counter Overload :This OID when set indicates an output Packets counter overload on client port |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| Pmlma10AdjustValue | INTEGER { otxadjustvalue0(0), otxadjustvalue1(1), otxadjustvalue2(2), otxadjustvalue3(3), otxadjustvalue4(4), otxadjustvalue5(5), otxadjustvalue6(6), otxadjustvalue7(7), otxadjustvalue8(8), otxadjustvalue9(9), otxadjustvalue10(10) } | current | Different values in Adjust mode on OTX-TLH on client and line ports |
| Pmlma10ClientIgnoreTimer | INTEGER { ignoretimerclientvalue0(0), ignoretimerclientvalue1(1), ignoretimerclientvalue2(2), ignoretimerclientvalue3(3), ignoretimerclientvalue4(4), ignoretimerclientvalue5(5), ignoretimerclientvalue6(6), ignoretimerclientvalue7(7), ignoretimerclientvalue8(8), ignoretimerclientvalue9(9), ignoretimerclientvalue10(10) } | current | Different values on the ignore timer on the client ports |
| Pmlma10ClientProtocol | INTEGER { protocolclientvalue0(0), protocolclientvalue1(1), protocolclientvalue2(2), protocolclientvalue3(3), protocolclientvalue4(4), protocolclientvalue5(5), protocolclientvalue6(6), protocolclientvalue7(7), protocolclientvalue8(8) } | current | Different values on the protocol on the client ports |
| Pmlma10DccMode | INTEGER { dccNo(0), dccLine1(1), dccLine2(2) } | current | Mode for DCC |
| Pmlma10MultiRate | INTEGER { rate100Mhz(0), rate250Mhz(1), rate500Mhz(2), rate1Ghz(3) } | current | different rate for a client port |
| Pmlma10OrxChannel | INTEGER | current | Channel selection on transceiver Rx line ports |
| Pmlma10OtxChannel | INTEGER | current | Channel selection on transceiver Tx line ports |
| Pmlma10OtxGrid | INTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50) } | current | Different grids on OTX-TLH on client and line ports |
| Pmlma10OtxMode | INTEGER { otx80mode(1), otx60mode(2), otxadjustmode(4) } | current | Different modes on OTX-TLH on client and line ports |
| Pmlma10ProtocolMode | INTEGER { protocolmodevalue0(0), protocolmodevalue1(1), protocolmodevalue2(2), protocolmodevalue3(3) } | current | Different values on the protocol mode |