EKINOPS-Pmlma10-MIB

414 objects
Creation.
OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.68IdentitymodulePmlma10Creation.
1.3.6.1.4.1.20044.68.2Nodepmlma10alarms
1.3.6.1.4.1.20044.68.2.1Nodepmlma10AlmOther
1.3.6.1.4.1.20044.68.2.1.1Nodepmlma10AlmOtherNurg
1.3.6.1.4.1.20044.68.2.1.1.2Nodepmlma10AlmsynthAlm2
1.3.6.1.4.1.20044.68.2.1.1.2.1Scalarpmlma10AlmConfTableSaveread-onlycurrentPM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> infor…
1.3.6.1.4.1.20044.68.2.1.1.2.2Scalarpmlma10AlmInvUploadread-onlycurrentInventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> informationalStatus(1000) <Alarmtype> ot…
1.3.6.1.4.1.20044.68.2.1.1.2.3Scalarpmlma10AlmConfTableLoadread-onlycurrentPM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> informationalStat…
1.3.6.1.4.1.20044.68.2.1.1.2.4Scalarpmlma10AlmCorrelatOffread-onlycurrentNot Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> informationalStatus(1000) <Alarmtype…
1.3.6.1.4.1.20044.68.2.1.2Nodepmlma10AlmOtherUrg
1.3.6.1.4.1.20044.68.2.1.3Nodepmlma10AlmOtherCrit
1.3.6.1.4.1.20044.68.2.1.3.0Nodepmlma10AlmsynthAlm0
1.3.6.1.4.1.20044.68.2.1.3.0.9Scalarpmlma10AlmModGlobFailread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the RM <Help> This alarm is set on detection of a failure originating from the equip…
1.3.6.1.4.1.20044.68.2.1.3.0.15Scalarpmlma10AlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.68.2.1.3.0.16Scalarpmlma10AlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.68.2.2Nodepmlma10AlmClient
1.3.6.1.4.1.20044.68.2.2.1Nodepmlma10AlmClientNurg
1.3.6.1.4.1.20044.68.2.2.1.232Tablepmlma10AlmclientSfpWarnDdmTablenot-accessiblecurrentList of pmlma10AlmclientSfpWarnDdm Article
1.3.6.1.4.1.20044.68.2.2.1.232.1Rowpmlma10AlmclientSfpWarnDdmEntrynot-accessiblecurrentRow definition for the pmlma10AlmclientSfpWarnDdm table
1.3.6.1.4.1.20044.68.2.2.1.232.1.1Columnpmlma10AlmclientSfpWarnDdmIndexread-onlycurrentIndex definition for the pmlma10AlmclientSfpWarnDdm table
1.3.6.1.4.1.20044.68.2.2.1.232.1.2Columnpmlma10AlmClientTxPwLowWngPortnread-onlycurrentClient Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.68.2.2.1.232.1.3Columnpmlma10AlmClientTxPwrHighWngPortnread-onlycurrentClient Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.68.2.2.1.232.1.4Columnpmlma10AlmClientTxBiasLowWngPortnread-onlycurrentClient Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.68.2.2.1.232.1.5Columnpmlma10AlmClientTxBiasHighWngPortnread-onlycurrentClient Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warn…
1.3.6.1.4.1.20044.68.2.2.1.232.1.6Columnpmlma10AlmClientVccLowWngPortnread-onlycurrentClient Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Warn…
1.3.6.1.4.1.20044.68.2.2.1.232.1.7Columnpmlma10AlmClientVccHighWngPortnread-onlycurrentClient Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Wa…
1.3.6.1.4.1.20044.68.2.2.1.232.1.8Columnpmlma10AlmClientTempLowWngPortnread-onlycurrentClient Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indic…
1.3.6.1.4.1.20044.68.2.2.1.232.1.9Columnpmlma10AlmClientTempHighWngPortnread-onlycurrentClient Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning ind…
1.3.6.1.4.1.20044.68.2.2.1.232.1.16Columnpmlma10AlmClientRxPwrLowWngPortnread-onlycurrentClient Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning i…
1.3.6.1.4.1.20044.68.2.2.1.232.1.17Columnpmlma10AlmClientRxPwrHighWngPortnread-onlycurrentClient Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning…
1.3.6.1.4.1.20044.68.2.2.2Nodepmlma10AlmClientUrg
1.3.6.1.4.1.20044.68.2.2.2.88Tablepmlma10AlmclientHostLaneFaultTablenot-accessiblecurrentList of pmlma10AlmclientHostLaneFault Article
1.3.6.1.4.1.20044.68.2.2.2.88.1Rowpmlma10AlmclientHostLaneFaultEntrynot-accessiblecurrentRow definition for the pmlma10AlmclientHostLaneFault table
1.3.6.1.4.1.20044.68.2.2.2.88.1.1Columnpmlma10AlmclientHostLaneFaultIndexread-onlycurrentIndex definition for the pmlma10AlmclientHostLaneFault table
1.3.6.1.4.1.20044.68.2.2.2.88.1.2Columnpmlma10AlmClientLossOfSyncPortnread-onlycurrentClient Frame Alignment Loss :This OID indicates the module is not aligned with the incoming Client signal <Help> Alarm indicating the module is not aligned wit…
1.3.6.1.4.1.20044.68.2.2.2.88.1.3Columnpmlma10AlmClientInputLossOfSigPortnread-onlycurrentClient Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Client Trscv <Help> Alarm indicating a Loss of Signal is detected on the Cl…
1.3.6.1.4.1.20044.68.2.2.2.88.1.7Columnpmlma10AlmClientCsfDetectedPortnread-onlycurrentClient Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client…
1.3.6.1.4.1.20044.68.2.2.2.88.1.11Columnpmlma10AlmClientLaneTxFifoErrorPortnread-onlycurrentClient Tx FIFO Error :This OID indicates a Tx FIFO Error on the Client Trscv <Help> Alarm indicating a Tx FIFO Error on the Client Trscv <Condtype> CLIENT_LANE…
1.3.6.1.4.1.20044.68.2.2.2.216Tablepmlma10AlmclientSfpAlmDdmTablenot-accessiblecurrentList of pmlma10AlmclientSfpAlmDdm Article
1.3.6.1.4.1.20044.68.2.2.2.216.1Rowpmlma10AlmclientSfpAlmDdmEntrynot-accessiblecurrentRow definition for the pmlma10AlmclientSfpAlmDdm table
1.3.6.1.4.1.20044.68.2.2.2.216.1.1Columnpmlma10AlmclientSfpAlmDdmIndexread-onlycurrentIndex definition for the pmlma10AlmclientSfpAlmDdm table
1.3.6.1.4.1.20044.68.2.2.2.216.1.2Columnpmlma10AlmClientTxPwrLowAlaPortnread-onlycurrentClient Trscv Tx Power Low :This OID indicates that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in…
1.3.6.1.4.1.20044.68.2.2.2.216.1.3Columnpmlma10AlmClientTxPwrHighAlaPortnread-onlycurrentClient Trscv Tx Power High :This OID indicates that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.68.2.2.2.216.1.4Columnpmlma10AlmClientTxBiasLowAlaPortnread-onlycurrentClient Trscv Bias Low :This OID indicates that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.68.2.2.2.216.1.5Columnpmlma10AlmClientTxBiasHighAlaPortnread-onlycurrentClient Trscv Bias High :This OID indicates that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM <Help> Alar…
1.3.6.1.4.1.20044.68.2.2.2.216.1.6Columnpmlma10AlmClientVccLowAlaPortnread-onlycurrentClient Trscv Power Supply Low :This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM <Help> Alar…
1.3.6.1.4.1.20044.68.2.2.2.216.1.7Columnpmlma10AlmClientVccHighAlaPortnread-onlycurrentClient Trscv Power Supply High :This OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM <Help> Al…
1.3.6.1.4.1.20044.68.2.2.2.216.1.8Columnpmlma10AlmClientTempLowAlaPortnread-onlycurrentClient Trscv Temp Low :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicat…
1.3.6.1.4.1.20044.68.2.2.2.216.1.9Columnpmlma10AlmClientTempHighAlaPortnread-onlycurrentClient Trscv Temp High :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indic…
1.3.6.1.4.1.20044.68.2.2.2.216.1.16Columnpmlma10AlmClientRxPwrLowAlaPortnread-onlycurrentClient Trscv Rx Power Low :This OID indicates that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm ind…
1.3.6.1.4.1.20044.68.2.2.2.216.1.17Columnpmlma10AlmClientRxPwrHighAlaPortnread-onlycurrentClient Trscv Rx Power High :This OID indicates that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm i…
1.3.6.1.4.1.20044.68.2.2.3Nodepmlma10AlmClientCrit
1.3.6.1.4.1.20044.68.2.2.3.8Tablepmlma10AlmsynthAlmPortTablenot-accessiblecurrentList of pmlma10AlmsynthAlmPort Article
1.3.6.1.4.1.20044.68.2.2.3.8.1Rowpmlma10AlmsynthAlmPortEntrynot-accessiblecurrentRow definition for the pmlma10AlmsynthAlmPort table
1.3.6.1.4.1.20044.68.2.2.3.8.1.1Columnpmlma10AlmsynthAlmPortIndexread-onlycurrentIndex definition for the pmlma10AlmsynthAlmPort table
1.3.6.1.4.1.20044.68.2.2.3.8.1.2Columnpmlma10AlmSfpAbsentPortnread-onlycurrentClient Optical Module Absent :This OID indicates that the Transceiver is not present in the client port. <Help> This alarm indicates if the client transceiver …
1.3.6.1.4.1.20044.68.2.2.3.8.1.3Columnpmlma10AlmDdmAbsentPortnread-onlycurrentDDM Supported On Client Trscv :This OID indicates that the Client transceiver supports the Digital Diagnostic Monitoring function <Help> This status indicates …
1.3.6.1.4.1.20044.68.2.2.3.8.1.5Columnpmlma10AlmHwFailAccPortnread-onlycurrentClient HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Help> This alarm indicates a failure on client port, most pro…
1.3.6.1.4.1.20044.68.2.2.3.8.1.6Columnpmlma10AlmDwLsdPortnread-onlycurrentClient Trscv Laser Shutdown :This OID indicates the Client transceiver laser is shutdown <Help> This status indicates if the client transceiver laser is shutdo…
1.3.6.1.4.1.20044.68.2.2.3.8.1.7Columnpmlma10AlmClientLocalOosPortnread-onlycurrentLocal Client Port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local c…
1.3.6.1.4.1.20044.68.2.2.3.8.1.8Columnpmlma10AlmClientRemoteOosPortnread-onlycurrentRemote Client Port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the remot…
1.3.6.1.4.1.20044.68.2.2.3.8.1.9Columnpmlma10AlmDwCaisPortnread-onlycurrentClient AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indicates if a Client Alarm Indication Signal is…
1.3.6.1.4.1.20044.68.2.2.3.8.1.10Columnpmlma10AlmSfpDdmWarningPortnread-onlycurrentWarning On Client Trscv DDM :This OID indicates a warning is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Warning has be…
1.3.6.1.4.1.20044.68.2.2.3.8.1.11Columnpmlma10AlmSfpDdmAlmPortnread-onlycurrentAlarm On Client Trscv DDM :This OID indicates an alarm is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Alarm has been de…
1.3.6.1.4.1.20044.68.2.2.3.8.1.13Columnpmlma10AlmFailAccPortnread-onlycurrentClient Access Fail :This OID indicates a failure on the Client port <Help> This alarm indicates a failure on the Client port <Condtype> FAIL_ACC_1 <Probcause> …
1.3.6.1.4.1.20044.68.2.2.3.8.1.17Columnpmlma10AlmUpCsfPortnread-onlycurrentClient Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu…
1.3.6.1.4.1.20044.68.2.3Nodepmlma10AlmLine
1.3.6.1.4.1.20044.68.2.3.1Nodepmlma10AlmLineNurg
1.3.6.1.4.1.20044.68.2.3.2Nodepmlma10AlmLineUrg
1.3.6.1.4.1.20044.68.2.3.2.104Tablepmlma10AlmlineNetworkLaneAlarmWarning1Tablenot-accessiblecurrentList of pmlma10AlmlineNetworkLaneAlarmWarning1 Article
1.3.6.1.4.1.20044.68.2.3.2.104.1Rowpmlma10AlmlineNetworkLaneAlarmWarning1Entrynot-accessiblecurrentRow definition for the pmlma10AlmlineNetworkLaneAlarmWarning1 table
1.3.6.1.4.1.20044.68.2.3.2.104.1.1Columnpmlma10AlmlineNetworkLaneAlarmWarning1Indexread-onlycurrentIndex definition for the pmlma10AlmlineNetworkLaneAlarmWarning1 table
1.3.6.1.4.1.20044.68.2.3.2.104.1.2Columnpmlma10AlmLineTxPwrLowAlaPortnread-onlycurrentLine Trscv Tx Power Low :This OID indicates that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indi…
1.3.6.1.4.1.20044.68.2.3.2.104.1.3Columnpmlma10AlmLineTxPwrHighAlaPortnread-onlycurrentLine Trscv Tx Power High :This OID indicates that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm in…
1.3.6.1.4.1.20044.68.2.3.2.104.1.4Columnpmlma10AlmLineTxBiasLowAlaPortnread-onlycurrentLine Trscv Bias Low :This OID indicates that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in…
1.3.6.1.4.1.20044.68.2.3.2.104.1.5Columnpmlma10AlmLineTxBiasHighAlaPortnread-onlycurrentLine Trscv Bias High :This OID indicates that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.68.2.3.2.104.1.6Columnpmlma10AlmLineVccLowAlaPortnread-onlycurrentLine Trscv Power Supply Low :This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.68.2.3.2.104.1.7Columnpmlma10AlmLineVccHighAlaPortnread-onlycurrentLine Trscv Power Supply High :This OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM <Help> Alar…
1.3.6.1.4.1.20044.68.2.3.2.104.1.8Columnpmlma10AlmLineTempLowAlaPortnread-onlycurrentLine Trscv Temp Low :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicatin…
1.3.6.1.4.1.20044.68.2.3.2.104.1.9Columnpmlma10AlmLineTempHighAlaPortnread-onlycurrentLine Trscv Temp High :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indicat…
1.3.6.1.4.1.20044.68.2.3.2.104.1.16Columnpmlma10AlmLineRxPwrLowAlaPortnread-onlycurrentLine Trscv Rx Power Low :This OID indicates that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indic…
1.3.6.1.4.1.20044.68.2.3.2.104.1.17Columnpmlma10AlmLineRxPwrHighAlaPortnread-onlycurrentLine Trscv Rx Power High :This OID indicates that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm ind…
1.3.6.1.4.1.20044.68.2.3.2.120Tablepmlma10AlmlineNetworkLaneAlarmWarning2Tablenot-accessiblecurrentList of pmlma10AlmlineNetworkLaneAlarmWarning2 Article
1.3.6.1.4.1.20044.68.2.3.2.120.1Rowpmlma10AlmlineNetworkLaneAlarmWarning2Entrynot-accessiblecurrentRow definition for the pmlma10AlmlineNetworkLaneAlarmWarning2 table
1.3.6.1.4.1.20044.68.2.3.2.120.1.1Columnpmlma10AlmlineNetworkLaneAlarmWarning2Indexread-onlycurrentIndex definition for the pmlma10AlmlineNetworkLaneAlarmWarning2 table
1.3.6.1.4.1.20044.68.2.3.2.120.1.2Columnpmlma10AlmLineTxPwLowWngPortnread-onlycurrentLine Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning in…
1.3.6.1.4.1.20044.68.2.3.2.120.1.3Columnpmlma10AlmLineTxPwrHighWngPortnread-onlycurrentLine Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.68.2.3.2.120.1.4Columnpmlma10AlmLineTxBiasLowWngPortnread-onlycurrentLine Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.68.2.3.2.120.1.5Columnpmlma10AlmLineTxBiasHighWngPortnread-onlycurrentLine Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.68.2.3.2.120.1.6Columnpmlma10AlmLineVccLowWngPortnread-onlycurrentLine Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.68.2.3.2.120.1.7Columnpmlma10AlmLineVccHighWngPortnread-onlycurrentLine Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Warn…
1.3.6.1.4.1.20044.68.2.3.2.120.1.8Columnpmlma10AlmLineTempLowWngPortnread-onlycurrentLine Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indicat…
1.3.6.1.4.1.20044.68.2.3.2.120.1.9Columnpmlma10AlmLineTempHighWngPortnread-onlycurrentLine Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning indic…
1.3.6.1.4.1.20044.68.2.3.2.120.1.16Columnpmlma10AlmLineRxPwrLowWngPortnread-onlycurrentLine Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning ind…
1.3.6.1.4.1.20044.68.2.3.2.120.1.17Columnpmlma10AlmLineRxPwrHighWngPortnread-onlycurrentLine Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning i…
1.3.6.1.4.1.20044.68.2.3.2.152Tablepmlma10AlmlineHostLaneFaultTablenot-accessiblecurrentList of pmlma10AlmlineHostLaneFault Article
1.3.6.1.4.1.20044.68.2.3.2.152.1Rowpmlma10AlmlineHostLaneFaultEntrynot-accessiblecurrentRow definition for the pmlma10AlmlineHostLaneFault table
1.3.6.1.4.1.20044.68.2.3.2.152.1.1Columnpmlma10AlmlineHostLaneFaultIndexread-onlycurrentIndex definition for the pmlma10AlmlineHostLaneFault table
1.3.6.1.4.1.20044.68.2.3.2.152.1.2Columnpmlma10AlmLineInputLossOfSignalPortnread-onlycurrentLine Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Line Trscv <Help> Alarm indicating a Loss of Signal is detected on the Line T…
1.3.6.1.4.1.20044.68.2.3.2.152.1.3Columnpmlma10AlmLineLossOfFramePortnread-onlycurrentLine Loss Of Frame :This OID indicates the module is not aligned with the incoming Line signal <Help> Alarm indicating the module is not aligned with the incom…
1.3.6.1.4.1.20044.68.2.3.2.152.1.4Columnpmlma10AlmLineSmBdiInsertedPortnread-onlycurrentLine SM BDI Inserted :This OID indicates a SM Backward Defect Indication is inserted on the outgoing Line signal <Help> Status indicating a SM Backward Defect …
1.3.6.1.4.1.20044.68.2.3.2.152.1.5Columnpmlma10AlmLineSmBdiDetectedPortnread-onlycurrentLine SM BDI Detected :This OID indicates a SM Backward Defect Indication is detected on the incoming Line signal <Help> Alarm indicating a SM Backward Defect I…
1.3.6.1.4.1.20044.68.2.3.3Nodepmlma10AlmLineCrit
1.3.6.1.4.1.20044.68.2.3.3.24Tablepmlma10AlmsynthAlmLineTablenot-accessiblecurrentList of pmlma10AlmsynthAlmLine Article
1.3.6.1.4.1.20044.68.2.3.3.24.1Rowpmlma10AlmsynthAlmLineEntrynot-accessiblecurrentRow definition for the pmlma10AlmsynthAlmLine table
1.3.6.1.4.1.20044.68.2.3.3.24.1.1Columnpmlma10AlmsynthAlmLineIndexread-onlycurrentIndex definition for the pmlma10AlmsynthAlmLine table
1.3.6.1.4.1.20044.68.2.3.3.24.1.2Columnpmlma10AlmLineSfpAbsentPortnread-onlycurrentLine Optical Module Absent :This OID indicates that the line optical interface is not present. <Help> This alarm indicates if the line transceiver is not plugg…
1.3.6.1.4.1.20044.68.2.3.3.24.1.3Columnpmlma10AlmLineDdmAbsentPortnread-onlycurrentLine Optical Module Ready :This OID indicates that the optical interface is not operational. <Help> This status indicates if the line transceiver has been corr…
1.3.6.1.4.1.20044.68.2.3.3.24.1.5Columnpmlma10AlmLineHwFailPortnread-onlycurrentLine Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Help> This alarm indicates a failure on line port, most pr…
1.3.6.1.4.1.20044.68.2.3.3.24.1.6Columnpmlma10AlmLineTxOffPortnread-onlycurrentLine Trscv Laser Shutdown :This OID indicates the Line transceiver laser is shutdown <Help> This status indicates if the Line transceiver laser is shutdown <Co…
1.3.6.1.4.1.20044.68.2.3.3.24.1.7Columnpmlma10AlmLineLocalOosPortnread-onlycurrentLine Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service…
1.3.6.1.4.1.20044.68.2.3.3.24.1.9Columnpmlma10AlmUpRdiInsPortnread-onlycurrentMS-RDI/L-RDI Inserted On Line :This OID indicates an upstream MS-RDI/L-RDI has been inserted in the outgoing 10 Gb/s SDH/SONET signal. <Help> This status indic…
1.3.6.1.4.1.20044.68.2.3.3.24.1.10Columnpmlma10AlmLineDdmWarningPortnread-onlycurrentWarning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Warning has…
1.3.6.1.4.1.20044.68.2.3.3.24.1.11Columnpmlma10AlmLineDdmAlmPortnread-onlycurrentAlarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Alarm has been…
1.3.6.1.4.1.20044.68.2.3.3.24.1.13Columnpmlma10AlmLineFailPortnread-onlycurrentLine Port Failure :This OID indicates a failure on the line port <Help> This alarm indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipm…
1.3.6.1.4.1.20044.68.3Nodepmlma10measures
1.3.6.1.4.1.20044.68.3.1Nodepmlma10MesrOther
1.3.6.1.4.1.20044.68.3.2Nodepmlma10MesrClient
1.3.6.1.4.1.20044.68.3.2.16Tablepmlma10MesrclientTempTablenot-accessiblecurrentList of pmlma10MesrclientTemp Article
1.3.6.1.4.1.20044.68.3.2.16.1Rowpmlma10MesrclientTempEntrynot-accessiblecurrentRow definition for the pmlma10MesrclientTemp table
1.3.6.1.4.1.20044.68.3.2.16.1.1Columnpmlma10MesrclientTempIndexread-onlycurrentIndex definition for the pmlma10MesrclientTemp table
1.3.6.1.4.1.20044.68.3.2.16.1.2Columnpmlma10MesrclientTempPortnread-onlycurrentClient Optical Module Temperature :This OID gives the Laser temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Tem…
1.3.6.1.4.1.20044.68.3.2.32Tablepmlma10MesrclientTxBiasTablenot-accessiblecurrentList of pmlma10MesrclientTxBias Article
1.3.6.1.4.1.20044.68.3.2.32.1Rowpmlma10MesrclientTxBiasEntrynot-accessiblecurrentRow definition for the pmlma10MesrclientTxBias table
1.3.6.1.4.1.20044.68.3.2.32.1.1Columnpmlma10MesrclientTxBiasIndexread-onlycurrentIndex definition for the pmlma10MesrclientTxBias table
1.3.6.1.4.1.20044.68.3.2.32.1.2Columnpmlma10MesrclientTxBiasPortnread-onlycurrentClient Optical Module Bias :This OID gives the Laser bias value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (U…
1.3.6.1.4.1.20044.68.3.2.48Tablepmlma10MesrclientTxPwrTablenot-accessiblecurrentList of pmlma10MesrclientTxPwr Article
1.3.6.1.4.1.20044.68.3.2.48.1Rowpmlma10MesrclientTxPwrEntrynot-accessiblecurrentRow definition for the pmlma10MesrclientTxPwr table
1.3.6.1.4.1.20044.68.3.2.48.1.1Columnpmlma10MesrclientTxPwrIndexread-onlycurrentIndex definition for the pmlma10MesrclientTxPwr table
1.3.6.1.4.1.20044.68.3.2.48.1.2Columnpmlma10MesrclientTxPwrPortnread-onlycurrentClient Optical Module Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 1…
1.3.6.1.4.1.20044.68.3.2.64Tablepmlma10MesrclientRxPwrTablenot-accessiblecurrentList of pmlma10MesrclientRxPwr Article
1.3.6.1.4.1.20044.68.3.2.64.1Rowpmlma10MesrclientRxPwrEntrynot-accessiblecurrentRow definition for the pmlma10MesrclientRxPwr table
1.3.6.1.4.1.20044.68.3.2.64.1.1Columnpmlma10MesrclientRxPwrIndexread-onlycurrentIndex definition for the pmlma10MesrclientRxPwr table
1.3.6.1.4.1.20044.68.3.2.64.1.2Columnpmlma10MesrclientRxPwrPortnread-onlycurrentClient Optical Module Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*l…
1.3.6.1.4.1.20044.68.3.3Nodepmlma10MesrLine
1.3.6.1.4.1.20044.68.3.3.80Tablepmlma10MesrlineTxPwrTablenot-accessiblecurrentList of pmlma10MesrlineTxPwr Article
1.3.6.1.4.1.20044.68.3.3.80.1Rowpmlma10MesrlineTxPwrEntrynot-accessiblecurrentRow definition for the pmlma10MesrlineTxPwr table
1.3.6.1.4.1.20044.68.3.3.80.1.1Columnpmlma10MesrlineTxPwrIndexread-onlycurrentIndex definition for the pmlma10MesrlineTxPwr table
1.3.6.1.4.1.20044.68.3.3.80.1.2Columnpmlma10MesrlineTxPwrPortnread-onlycurrentLine Optical Module Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power …
1.3.6.1.4.1.20044.68.3.3.96Tablepmlma10MesrlineTempTablenot-accessiblecurrentList of pmlma10MesrlineTemp Article
1.3.6.1.4.1.20044.68.3.3.96.1Rowpmlma10MesrlineTempEntrynot-accessiblecurrentRow definition for the pmlma10MesrlineTemp table
1.3.6.1.4.1.20044.68.3.3.96.1.1Columnpmlma10MesrlineTempIndexread-onlycurrentIndex definition for the pmlma10MesrlineTemp table
1.3.6.1.4.1.20044.68.3.3.96.1.2Columnpmlma10MesrlineTempPortnread-onlycurrentLine Optical Module Temperature :This OID gives the Tx Laser Temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temp…
1.3.6.1.4.1.20044.68.3.3.112Tablepmlma10MesrlineTxBiasTablenot-accessiblecurrentList of pmlma10MesrlineTxBias Article
1.3.6.1.4.1.20044.68.3.3.112.1Rowpmlma10MesrlineTxBiasEntrynot-accessiblecurrentRow definition for the pmlma10MesrlineTxBias table
1.3.6.1.4.1.20044.68.3.3.112.1.1Columnpmlma10MesrlineTxBiasIndexread-onlycurrentIndex definition for the pmlma10MesrlineTxBias table
1.3.6.1.4.1.20044.68.3.3.112.1.2Columnpmlma10MesrlineTxBiasPortnread-onlycurrentLine Optical Module Laser Bias :This OID gives the Tx Laser Bias value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/50…
1.3.6.1.4.1.20044.68.3.3.128Tablepmlma10MesrlineRxPwrTablenot-accessiblecurrentList of pmlma10MesrlineRxPwr Article
1.3.6.1.4.1.20044.68.3.3.128.1Rowpmlma10MesrlineRxPwrEntrynot-accessiblecurrentRow definition for the pmlma10MesrlineRxPwr table
1.3.6.1.4.1.20044.68.3.3.128.1.1Columnpmlma10MesrlineRxPwrIndexread-onlycurrentIndex definition for the pmlma10MesrlineRxPwr table
1.3.6.1.4.1.20044.68.3.3.128.1.2Columnpmlma10MesrlineRxPwrPortnread-onlycurrentLine Optical Module Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(A…
1.3.6.1.4.1.20044.68.4Nodepmlma10counters
1.3.6.1.4.1.20044.68.4.1Nodepmlma10CntOther
1.3.6.1.4.1.20044.68.4.2Nodepmlma10CntClient
1.3.6.1.4.1.20044.68.4.2.96Tablepmlma10CntclientCbipCounterTablenot-accessiblecurrentList of pmlma10CntclientCbipCounter Article
1.3.6.1.4.1.20044.68.4.2.96.1Rowpmlma10CntclientCbipCounterEntrynot-accessiblecurrentRow definition for the pmlma10CntclientCbipCounter table
1.3.6.1.4.1.20044.68.4.2.96.1.1Columnpmlma10CntclientCbipCounterIndexread-onlycurrentIndex definition for the pmlma10CntclientCbipCounter table
1.3.6.1.4.1.20044.68.4.2.96.1.2Columnpmlma10CntclientCbipCounterValuePortnread-onlycurrentClient Output Errors :This counter is incremented each time a CBIP parity error is detected on the Client output stream <Help> This counter gives the number of…
1.3.6.1.4.1.20044.68.4.2.96.1.3Columnpmlma10CntclientCbipCounterErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the CBIP error counter value is invalid on Port
1.3.6.1.4.1.20044.68.4.2.96.1.4Columnpmlma10CntclientCbipCounterOverloadPortnread-onlycurrentClient CBIP Counter Overload :This OID when set indicates a CBIP error counter overload on Port
1.3.6.1.4.1.20044.68.4.3Nodepmlma10CntLine
1.3.6.1.4.1.20044.68.4.3.192Tablepmlma10CntlocalLineSmBip8ErrorCounterTablenot-accessiblecurrentList of pmlma10CntlocalLineSmBip8ErrorCounter Article
1.3.6.1.4.1.20044.68.4.3.192.1Rowpmlma10CntlocalLineSmBip8ErrorCounterEntrynot-accessiblecurrentRow definition for the pmlma10CntlocalLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.68.4.3.192.1.1Columnpmlma10CntlocalLineSmBip8ErrorCounterIndexread-onlycurrentIndex definition for the pmlma10CntlocalLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.68.4.3.192.1.2Columnpmlma10CntlocalLineSmBip8ErrorCounterValuePortnread-onlycurrentLine Input SM-BIP8 Errors :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC <Help> This counter gives the current Bit Error Rate (r…
1.3.6.1.4.1.20044.68.4.3.192.1.3Columnpmlma10CntlocalLineSmBip8ErrorCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the B1 error counter value is invalid on Port
1.3.6.1.4.1.20044.68.4.3.192.1.4Columnpmlma10CntlocalLineSmBip8ErrorCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a B1 error counter overload on Port
1.3.6.1.4.1.20044.68.4.3.200Tablepmlma10CntlocalLineFecCorrectedErrorsCounterTablenot-accessiblecurrentList of pmlma10CntlocalLineFecCorrectedErrorsCounter Article
1.3.6.1.4.1.20044.68.4.3.200.1Rowpmlma10CntlocalLineFecCorrectedErrorsCounterEntrynot-accessiblecurrentRow definition for the pmlma10CntlocalLineFecCorrectedErrorsCounter table
1.3.6.1.4.1.20044.68.4.3.200.1.1Columnpmlma10CntlocalLineFecCorrectedErrorsCounterIndexread-onlycurrentIndex definition for the pmlma10CntlocalLineFecCorrectedErrorsCounter table
1.3.6.1.4.1.20044.68.4.3.200.1.2Columnpmlma10CntlocalLineFecCorrectedErrorsCounterValuePortnread-onlycurrentLine Input HD FEC Corrected Errors :This OID gives the current Bit Error Rate before the Hard Decision FEC <Help> This counter gives the current Bit Error Rate…
1.3.6.1.4.1.20044.68.4.3.200.1.3Columnpmlma10CntlocalLineFecCorrectedErrorsCounterErrorPortnread-onlycurrentFEC Counter Error :This bit when set indicates the FEC corrected errors counter value is invalid on Line
1.3.6.1.4.1.20044.68.4.3.200.1.4Columnpmlma10CntlocalLineFecCorrectedErrorsCounterOverloadPortnread-onlycurrentFEC Counter Overload :This bit when set indicates a FEC corrected errors counter overload on Line
1.3.6.1.4.1.20044.68.4.3.208Tablepmlma10CntremoteLineSmBip8ErrorCounterTablenot-accessiblecurrentList of pmlma10CntremoteLineSmBip8ErrorCounter Article
1.3.6.1.4.1.20044.68.4.3.208.1Rowpmlma10CntremoteLineSmBip8ErrorCounterEntrynot-accessiblecurrentRow definition for the pmlma10CntremoteLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.68.4.3.208.1.1Columnpmlma10CntremoteLineSmBip8ErrorCounterIndexread-onlycurrentIndex definition for the pmlma10CntremoteLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.68.4.3.208.1.2Columnpmlma10CntremoteLineSmBip8ErrorCounterValuePortnread-onlycurrentRemote SM BIP8 :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC on the remote side <Help> This counter gives the current Bit Error…
1.3.6.1.4.1.20044.68.4.3.208.1.3Columnpmlma10CntremoteLineSmBip8ErrorCounterErrorPortnread-onlycurrentRemote Counter Error :
1.3.6.1.4.1.20044.68.4.3.208.1.4Columnpmlma10CntremoteLineSmBip8ErrorCounterOverloadPortnread-onlycurrentRemote Counter Overload :
1.3.6.1.4.1.20044.68.4.3.216Tablepmlma10CntlineDfrmTimCntTablenot-accessiblecurrentList of pmlma10CntlineDfrmTimCnt Article
1.3.6.1.4.1.20044.68.4.3.216.1Rowpmlma10CntlineDfrmTimCntEntrynot-accessiblecurrentRow definition for the pmlma10CntlineDfrmTimCnt table
1.3.6.1.4.1.20044.68.4.3.216.1.1Columnpmlma10CntlineDfrmTimCntIndexread-onlycurrentIndex definition for the pmlma10CntlineDfrmTimCnt table
1.3.6.1.4.1.20044.68.4.3.216.1.2Columnpmlma10CntlineDfrmTimCntValuePortnread-onlycurrentLine Timer Counter :
1.3.6.1.4.1.20044.68.4.3.216.1.3Columnpmlma10CntlineDfrmTimCntErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.68.4.3.216.1.4Columnpmlma10CntlineDfrmTimCntOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.68.4.259Scalarpmlma10CntCountersResetread-writecurrentCounters Reset:This OID resets and restarts all the counters
1.3.6.1.4.1.20044.68.4.260Scalarpmlma10CntCountersStopread-writecurrentCounters stop:This OID stops all the counters
1.3.6.1.4.1.20044.68.6Nodepmlma10controlsWrite
1.3.6.1.4.1.20044.68.6.1Nodepmlma10CtrlOther
1.3.6.1.4.1.20044.68.6.1.1Nodepmlma10CtrlconfMgnt1
1.3.6.1.4.1.20044.68.6.1.1.1Scalarpmlma10CtrlConf1Load1read-writecurrentLoad Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM.
1.3.6.1.4.1.20044.68.6.1.1.2Scalarpmlma10CtrlConf2Load1read-writecurrentLoad Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM.
1.3.6.1.4.1.20044.68.6.1.1.10Scalarpmlma10CtrlConf2Flash1read-writecurrentWrite Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura…
1.3.6.1.4.1.20044.68.6.1.1.14Scalarpmlma10CtrlConf2Clear1read-writecurrentClear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o…
1.3.6.1.4.1.20044.68.6.1.4Nodepmlma10Ctrlsynth4
1.3.6.1.4.1.20044.68.6.1.4.1Scalarpmlma10CtrlCorrelatOnread-writecurrentEnable Alarm Correlation :This OID enables the alarm correlation in the PM.
1.3.6.1.4.1.20044.68.6.1.4.2Scalarpmlma10CtrlCorrelatOffread-writecurrentDisable Alarm Correlation :This OID disables the alarm correlation in the PM.
1.3.6.1.4.1.20044.68.6.1.5Nodepmlma10CtrlswMgnt
1.3.6.1.4.1.20044.68.6.1.5.2Scalarpmlma10CtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> …
1.3.6.1.4.1.20044.68.6.1.5.3Scalarpmlma10CtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th…
1.3.6.1.4.1.20044.68.6.1.5.5Scalarpmlma10CtrlLoadSwBank1read-writecurrentSet Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW…
1.3.6.1.4.1.20044.68.6.1.5.6Scalarpmlma10CtrlLoadSwBank2read-writecurrentSet Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S…
1.3.6.1.4.1.20044.68.6.1.6Nodepmlma10CtrlgwMgnt
1.3.6.1.4.1.20044.68.6.1.6.1Scalarpmlma10CtrlCurrentGwResetread-writecurrentActive Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting.
1.3.6.1.4.1.20044.68.6.1.6.5Scalarpmlma10CtrlLoadGwBank1read-writecurrentSet Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.68.6.1.6.6Scalarpmlma10CtrlLoadGwBank2read-writecurrentSet Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.68.6.1.6.7Scalarpmlma10CtrlLoadGwBank3read-writecurrentSet Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.68.6.1.6.8Scalarpmlma10CtrlLoadGwBank4read-writecurrentSet Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.68.6.1.192Nodepmlma10CtrlledTest
1.3.6.1.4.1.20044.68.6.1.192.1Scalarpmlma10CtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.68.6.1.192.2Scalarpmlma10CtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.68.6.1.192.3Scalarpmlma10CtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.68.6.2Nodepmlma10CtrlClient
1.3.6.1.4.1.20044.68.6.2.16Tablepmlma10CtrlaccessLoopTablenot-accessiblecurrentList of pmlma10CtrlaccessLoop Article
1.3.6.1.4.1.20044.68.6.2.16.1Rowpmlma10CtrlaccessLoopEntrynot-accessiblecurrentRow definition for the pmlma10CtrlaccessLoop table
1.3.6.1.4.1.20044.68.6.2.16.1.1Columnpmlma10CtrlaccessLoopIndexread-onlycurrentIndex definition for the pmlma10CtrlaccessLoop table
1.3.6.1.4.1.20044.68.6.2.16.1.2Columnpmlma10CtrlaccessLoopPortnread-writecurrentClient Facility Loopback :This OID, when set at '1' puts the client port in loopback, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. <Help…
1.3.6.1.4.1.20044.68.6.2.17Tablepmlma10CtrlclientLoopToLineTablenot-accessiblecurrentList of pmlma10CtrlclientLoopToLine Article
1.3.6.1.4.1.20044.68.6.2.17.1Rowpmlma10CtrlclientLoopToLineEntrynot-accessiblecurrentRow definition for the pmlma10CtrlclientLoopToLine table
1.3.6.1.4.1.20044.68.6.2.17.1.1Columnpmlma10CtrlclientLoopToLineIndexread-onlycurrentIndex definition for the pmlma10CtrlclientLoopToLine table
1.3.6.1.4.1.20044.68.6.2.17.1.2Columnpmlma10CtrlclientLoopToLinePortnread-writecurrentClient Terminal Loopback :This OID, when set, puts the client port in loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.<Help> This control ena…
1.3.6.1.4.1.20044.68.6.2.21Tablepmlma10CtrlcsfUpInsTablenot-accessiblecurrentList of pmlma10CtrlcsfUpIns Article
1.3.6.1.4.1.20044.68.6.2.21.1Rowpmlma10CtrlcsfUpInsEntrynot-accessiblecurrentRow definition for the pmlma10CtrlcsfUpIns table
1.3.6.1.4.1.20044.68.6.2.21.1.1Columnpmlma10CtrlcsfUpInsIndexread-onlycurrentIndex definition for the pmlma10CtrlcsfUpIns table
1.3.6.1.4.1.20044.68.6.2.21.1.2Columnpmlma10CtrlcsfUpInsPortnread-writecurrentClient Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo…
1.3.6.1.4.1.20044.68.6.2.22Tablepmlma10CtrlcaisDwInsTablenot-accessiblecurrentList of pmlma10CtrlcaisDwIns Article
1.3.6.1.4.1.20044.68.6.2.22.1Rowpmlma10CtrlcaisDwInsEntrynot-accessiblecurrentRow definition for the pmlma10CtrlcaisDwIns table
1.3.6.1.4.1.20044.68.6.2.22.1.1Columnpmlma10CtrlcaisDwInsIndexread-onlycurrentIndex definition for the pmlma10CtrlcaisDwIns table
1.3.6.1.4.1.20044.68.6.2.22.1.2Columnpmlma10CtrlcaisDwInsPortnread-writecurrentClient AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port
1.3.6.1.4.1.20044.68.6.3Nodepmlma10CtrlLine
1.3.6.1.4.1.20044.68.6.3.64Tablepmlma10CtrlcommAccessLoopTablenot-accessiblecurrentList of pmlma10CtrlcommAccessLoop Article
1.3.6.1.4.1.20044.68.6.3.64.1Rowpmlma10CtrlcommAccessLoopEntrynot-accessiblecurrentRow definition for the pmlma10CtrlcommAccessLoop table
1.3.6.1.4.1.20044.68.6.3.64.1.1Columnpmlma10CtrlcommAccessLoopIndexread-onlycurrentIndex definition for the pmlma10CtrlcommAccessLoop table
1.3.6.1.4.1.20044.68.6.3.64.1.2Columnpmlma10CtrlcommAccessLoopPortnread-writecurrentLine Terminal Loopback :This OID, when set, puts the module in common access loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.<Help> This cont…
1.3.6.1.4.1.20044.68.6.3.66Tablepmlma10CtrllineLoopTablenot-accessiblecurrentList of pmlma10CtrllineLoop Article
1.3.6.1.4.1.20044.68.6.3.66.1Rowpmlma10CtrllineLoopEntrynot-accessiblecurrentRow definition for the pmlma10CtrllineLoop table
1.3.6.1.4.1.20044.68.6.3.66.1.1Columnpmlma10CtrllineLoopIndexread-onlycurrentIndex definition for the pmlma10CtrllineLoop table
1.3.6.1.4.1.20044.68.6.3.66.1.2Columnpmlma10CtrllineLoopPortnread-writecurrentLine Facility Loopback :This OID, when set at '1' puts the module in line loopback mode, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. Th…
1.3.6.1.4.1.20044.68.6.3.69Tablepmlma10CtrlfecDisableTablenot-accessiblecurrentList of pmlma10CtrlfecDisable Article
1.3.6.1.4.1.20044.68.6.3.69.1Rowpmlma10CtrlfecDisableEntrynot-accessiblecurrentRow definition for the pmlma10CtrlfecDisable table
1.3.6.1.4.1.20044.68.6.3.69.1.1Columnpmlma10CtrlfecDisableIndexread-onlycurrentIndex definition for the pmlma10CtrlfecDisable table
1.3.6.1.4.1.20044.68.6.3.69.1.2Columnpmlma10CtrlfecDisablePortnread-writecurrentForward Error Correction Inhibition :This OID, when set, inhibits the Forward Error Correction feature on the line input <Help> This control enables/disables t…
1.3.6.1.4.1.20044.68.7Nodepmlma10ri
1.3.6.1.4.1.20044.68.7.1Nodepmlma10riTable
1.3.6.1.4.1.20044.68.7.1.1Tablepmlma10RinvSfpTablenot-accessiblecurrentList of the SFPs on the selected module
1.3.6.1.4.1.20044.68.7.1.1.1Rowpmlma10RinvSfpEntrynot-accessiblecurrentRow definition for the SFP table
1.3.6.1.4.1.20044.68.7.1.1.1.1Columnpmlma10RinvSfpIndexread-onlycurrentIndex for SFP table
1.3.6.1.4.1.20044.68.7.1.1.1.2Columnpmlma10Rinvsfpread-onlycurrentInventory for the SFP: This OID contains the inventory for the SFP
1.3.6.1.4.1.20044.68.7.1.2Tablepmlma10RinvLineTablenot-accessiblecurrentList of the XFPs on the selected module
1.3.6.1.4.1.20044.68.7.1.2.1Rowpmlma10RinvLineEntrynot-accessiblecurrentRow definition for the XFP table
1.3.6.1.4.1.20044.68.7.1.2.1.1Columnpmlma10RinvLineIndexread-onlycurrentIndex for XFP table
1.3.6.1.4.1.20044.68.7.1.2.1.2Columnpmlma10RinvxfpLineread-onlycurrentInventory for the XFP: This OID contains the inventory for the XFP
1.3.6.1.4.1.20044.68.7.2Scalarpmlma10RinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.68.7.3Scalarpmlma10RinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.68.7.4Scalarpmlma10RinvModulePlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.68.7.5Scalarpmlma10RinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.68.7.6Scalarpmlma10RinvGwPlatformread-onlycurrentGW platform description: This OID contains the description of the Gateware platform.
1.3.6.1.4.1.20044.68.8Nodepmlma10download
1.3.6.1.4.1.20044.68.8.1Nodepmlma10DwlOther
1.3.6.1.4.1.20044.68.8.1.0Nodepmlma10DwlrestartProcess
1.3.6.1.4.1.20044.68.8.1.0.1Scalarpmlma10DwlWarmRestartProcessedread-onlycurrentWarm Restart :This OID indicates that the module last restart was a Warm RESTART
1.3.6.1.4.1.20044.68.8.1.0.2Scalarpmlma10DwlColdRestartProcessedread-onlycurrentCold Restart :This OID indicates that the module last restart was a Cold RESTART
1.3.6.1.4.1.20044.68.8.1.1Nodepmlma10DwlswBanksUsed
1.3.6.1.4.1.20044.68.8.1.1.1Scalarpmlma10DwlSwBank1Usedread-onlycurrentSW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby
1.3.6.1.4.1.20044.68.8.1.1.2Scalarpmlma10DwlSwBank2Usedread-onlycurrentSW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby
1.3.6.1.4.1.20044.68.8.1.1.5Scalarpmlma10DwlSwBank1Notemptyread-onlycurrentSW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package
1.3.6.1.4.1.20044.68.8.1.1.6Scalarpmlma10DwlSwBank2Notemptyread-onlycurrentSW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package
1.3.6.1.4.1.20044.68.8.1.2Nodepmlma10DwlgwBanksUsed
1.3.6.1.4.1.20044.68.8.1.2.1Scalarpmlma10DwlGwBank1Usedread-onlycurrentGW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby
1.3.6.1.4.1.20044.68.8.1.2.2Scalarpmlma10DwlGwBank2Usedread-onlycurrentGW bank 2 active :This OID indicates the module is working on GW bank 2
1.3.6.1.4.1.20044.68.8.1.2.3Scalarpmlma10DwlGwBank3Usedread-onlycurrentGW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby
1.3.6.1.4.1.20044.68.8.1.2.4Scalarpmlma10DwlGwBank4Usedread-onlycurrentGW bank 4 active :This OID indicates the module is working on GW bank 4
1.3.6.1.4.1.20044.68.8.1.2.5Scalarpmlma10DwlGwBank1Notemptyread-onlycurrentGW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package
1.3.6.1.4.1.20044.68.8.1.2.6Scalarpmlma10DwlGwBank2Notemptyread-onlycurrentGW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2
1.3.6.1.4.1.20044.68.8.1.2.7Scalarpmlma10DwlGwBank3Notemptyread-onlycurrentGW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package
1.3.6.1.4.1.20044.68.8.1.2.8Scalarpmlma10DwlGwBank4Notemptyread-onlycurrentGW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4
1.3.6.1.4.1.20044.68.8.2Nodepmlma10DwlClient
1.3.6.1.4.1.20044.68.8.3Nodepmlma10DwlLine
1.3.6.1.4.1.20044.68.9Nodepmlma10Config
1.3.6.1.4.1.20044.68.9.1Nodepmlma10CfgAccessCAisCsf
1.3.6.1.4.1.20044.68.9.1.1Tablepmlma10CfgClientcaiscsfTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.68.9.1.1.1Rowpmlma10CfgClientcaiscsfEntrynot-accessiblecurrentRow definition for the accessCAisCsf table
1.3.6.1.4.1.20044.68.9.1.1.1.1Columnpmlma10CfgClientcaiscsfIndexread-onlycurrentIndex definition for the clientcaiscsf table
1.3.6.1.4.1.20044.68.9.1.1.1.3Columnpmlma10CfgReservePortnread-writecurrentCAIS mode on Client Port :This register enables/disables port laser shutdown on CAIS insertion condition
1.3.6.1.4.1.20044.68.9.2Nodepmlma10CfgStartup
1.3.6.1.4.1.20044.68.9.2.1Tablepmlma10CfgClientStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.68.9.2.1.1Rowpmlma10CfgClientStartupEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.68.9.2.1.1.1Columnpmlma10CfgClientStartupIndexread-onlycurrentIndex definition for the clientStartup table
1.3.6.1.4.1.20044.68.9.2.1.1.3Columnpmlma10CfgSystConfPortPortnread-writecurrentDefault Settings on Client Port :This register configures the default initialisation settings on the port.
1.3.6.1.4.1.20044.68.9.2.1.1.4Columnpmlma10CfgNetConfPortPortnread-writecurrentDefault Settings on Client Port :This register configures the default initialisation settings on the port.
1.3.6.1.4.1.20044.68.9.2.1.1.14Columnpmlma10CfgOptionsPortPortnread-writecurrentDefault Options on Client Port :This register configures the default options on the port.
1.3.6.1.4.1.20044.68.9.2.2Tablepmlma10CfgLinexr1StartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.68.9.2.2.1Rowpmlma10CfgLinexr1StartupEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.68.9.2.2.1.1Columnpmlma10CfgLinexr1StartupIndexread-onlycurrentIndex definition for the linexr1Startup table
1.3.6.1.4.1.20044.68.9.2.2.1.3Columnpmlma10CfgSystConfLinePortnread-writecurrentDefault Settings on Line :This register configures the default initialisation settings on Line
1.3.6.1.4.1.20044.68.9.2.2.1.14Columnpmlma10CfgOptionsLinePortnread-writecurrentDefault Options on Line :This register configures the default options on the line
1.3.6.1.4.1.20044.68.9.2.3Tablepmlma10CfgEmptyTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.68.9.2.3.1Rowpmlma10CfgEmptyEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.68.9.2.3.1.1Columnpmlma10CfgEmptyIndexread-onlycurrentIndex definition for the empty table
1.3.6.1.4.1.20044.68.9.2.3.1.3Columnpmlma10CfgSystConfMsaLinePortnread-writecurrentDefault settings on MSA :This register configures the default initialisation settings on MSA
1.3.6.1.4.1.20044.68.9.3Nodepmlma10CfgLabels
1.3.6.1.4.1.20044.68.9.3.1Tablepmlma10CfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.68.9.3.1.1Rowpmlma10CfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.68.9.3.1.1.1Columnpmlma10CfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.68.9.3.1.1.3Columnpmlma10CfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.68.9.3.2Tablepmlma10CfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.68.9.3.2.1Rowpmlma10CfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.68.9.3.2.1.1Columnpmlma10CfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.68.9.3.2.1.3Columnpmlma10CfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.68.9.4Nodepmlma10CfgStartuptlh
1.3.6.1.4.1.20044.68.9.4.1Tablepmlma10CfgOtxtlhTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.68.9.4.1.1Rowpmlma10CfgOtxtlhEntrynot-accessiblecurrentRow definition for the startuptlh table
1.3.6.1.4.1.20044.68.9.4.1.1.1Columnpmlma10CfgOtxtlhIndexread-onlycurrentIndex definition for the otxtlh table
1.3.6.1.4.1.20044.68.9.4.1.1.6Columnpmlma10CfgLinePwrLaserPortnread-writecurrentDefaut Line output Power :This register configures the start-up output power of the Line tranceiver (Unit = dBm)
1.3.6.1.4.1.20044.68.9.4.1.1.7Columnpmlma10CfgLineFCurrentPortnread-writecurrentDefault Line transceiver Tx Channel :This register configures the start-up laser channel of the Line Tx transceiver
1.3.6.1.4.1.20044.68.9.4.1.1.8Columnpmlma10CfgLineGridCurrentPortnread-writecurrentDefault Line transceiver Grid :This register configures the start-up laser grid of the Line transceiver
1.3.6.1.4.1.20044.68.9.4.1.1.9Columnpmlma10CfgFPortnread-writecurrentDefault Line TRX lowest Freq :This register configures the start-up lowest frequency of the Line transceiver
1.3.6.1.4.1.20044.68.9.4.1.1.10Columnpmlma10CfgRxLineFCurrentPortnread-writecurrentDefault Line transceiver Rx Channel :This register configures the start-up laser channel of the Line Rx transceiver
1.3.6.1.4.1.20044.68.9.5Nodepmlma10CfgOther
1.3.6.1.4.1.20044.68.9.5.1Nodepmlma10tablemoduleOther
1.3.6.1.4.1.20044.68.9.5.1.2Scalarpmlma10Cfgmoderead-writecurrentDefault settings on Module :This register selects the configuration mode of the module
1.3.6.1.4.1.20044.68.9.6Nodepmlma10CfgStartuptablefive
1.3.6.1.4.1.20044.68.9.6.1Tablepmlma10CfgOtxtlhcapabilitiesTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.68.9.6.1.1Rowpmlma10CfgOtxtlhcapabilitiesEntrynot-accessiblecurrentRow definition for the startuptablefive table
1.3.6.1.4.1.20044.68.9.6.1.1.1Columnpmlma10CfgOtxtlhcapabilitiesIndexread-onlycurrentIndex definition for the otxtlhcapabilities table
1.3.6.1.4.1.20044.68.9.6.1.1.3Columnpmlma10CfgComponentTypePortnread-onlycurrentComponent parameters :This OID defines the component parameters
1.3.6.1.4.1.20044.68.9.6.1.1.4Columnpmlma10CfgMiscellaneousPortnread-onlycurrentMiscellaneous default settings :This OID defines the miscellaneous parameters
1.3.6.1.4.1.20044.68.9.6.1.1.5Columnpmlma10CfgFirstChannelPortnread-onlycurrentNumber of the first channel of the component :This OID defines the first channel number of the PM
1.3.6.1.4.1.20044.68.9.6.1.1.6Columnpmlma10CfgLastChannelPortnread-onlycurrentNumber of the last channel of the component :This OID defines the last channel number of the PM
1.3.6.1.4.1.20044.68.9.6.1.1.7Columnpmlma10CfgGridPortnread-onlycurrentGrid value of the component :This OID defines the grid of the PM
1.3.6.1.4.1.20044.68.9.257Scalarpmlma10CfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.68.10Nodepmlma10traps
1.3.6.1.4.1.20044.68.10.2Scalarpmlma10trapPortNumberread-onlycurrentLast port which generates a trap
1.3.6.1.4.1.20044.68.10.3Scalarpmlma10trapLineNumberread-onlycurrentLast Line which generates a trap
1.3.6.1.4.1.20044.68.10.4Scalarpmlma10trapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.68.10.30Notificationpmlma10LineTrapNotUrgentGoesOncurrentNot urgent Line default is activated
1.3.6.1.4.1.20044.68.10.31Notificationpmlma10LineTrapNotUrgentGoesOffcurrentNot urgent Line default disappeared
1.3.6.1.4.1.20044.68.10.32Notificationpmlma10LineTrapUrgentGoesOncurrentUrgent Line default is activated
1.3.6.1.4.1.20044.68.10.33Notificationpmlma10LineTrapUrgentGoesOffcurrentUrgent Line default disappeared
1.3.6.1.4.1.20044.68.10.34Notificationpmlma10LineTrapCritGoesOncurrentCritical Line default is activated
1.3.6.1.4.1.20044.68.10.35Notificationpmlma10LineTrapCritGoesOffcurrentCritical Line default disappeared
1.3.6.1.4.1.20044.68.10.40Notificationpmlma10ClientTrapNotUrgentGoesOncurrentNot urgent client default is activated
1.3.6.1.4.1.20044.68.10.41Notificationpmlma10ClientTrapNotUrgentGoesOffcurrentNot urgent client default disappeared
1.3.6.1.4.1.20044.68.10.42Notificationpmlma10ClientTrapUrgentGoesOncurrentUrgent client default is activated
1.3.6.1.4.1.20044.68.10.43Notificationpmlma10ClientTrapUrgentGoesOffcurrentUrgent client default disappeared
1.3.6.1.4.1.20044.68.10.44Notificationpmlma10ClientTrapCritGoesOncurrentCritical client default is activated
1.3.6.1.4.1.20044.68.10.45Notificationpmlma10ClientTrapCritGoesOffcurrentCritical client default disappeared
1.3.6.1.4.1.20044.68.10.50Notificationpmlma10PowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.68.10.51Notificationpmlma10PowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared
1.3.6.1.4.1.20044.68.11Nodepmlma10Monitoring
1.3.6.1.4.1.20044.68.11.1Nodepmlma10MonOther
1.3.6.1.4.1.20044.68.11.1.3Nodepmlma10MonRmon
1.3.6.1.4.1.20044.68.11.1.3.359Scalarpmlma10MonCountersResetread-writecurrentRMON Counters Reset:This OID resets and restarts all the RMON counters
1.3.6.1.4.1.20044.68.11.1.3.360Scalarpmlma10MonCountersStopread-writecurrentRMON Counters stop:This OID stops all the RMON counters
1.3.6.1.4.1.20044.68.11.2Nodepmlma10MonClient
1.3.6.1.4.1.20044.68.11.2.4Nodepmlma10MonClientRmonCounter
1.3.6.1.4.1.20044.68.11.2.4.16Tablepmlma10MonupRmonBytesCounterClientInputTablenot-accessiblecurrentList of pmlma10MonupRmonBytesCounterClientInput Article
1.3.6.1.4.1.20044.68.11.2.4.16.1Rowpmlma10MonupRmonBytesCounterClientInputEntrynot-accessiblecurrentRow definition for the pmlma10MonupRmonBytesCounterClientInput table
1.3.6.1.4.1.20044.68.11.2.4.16.1.1Columnpmlma10MonupRmonBytesCounterClientInputIndexread-onlycurrentIndex definition for the pmlma10MonupRmonBytesCounterClientInput table
1.3.6.1.4.1.20044.68.11.2.4.16.1.2Columnpmlma10MonupRmonBytesCounterClientInputValuePortnread-onlycurrentClient Input Bytes :This counter is increased each time a data byte is received on the client port <Help> This counter gives the number of bytes received on th…
1.3.6.1.4.1.20044.68.11.2.4.16.1.3Columnpmlma10MonupRmonBytesCounterClientInputErrorPortnread-onlycurrentBytes Counter Error :This OID when set indicates the Bytes counter value is invalid on client port
1.3.6.1.4.1.20044.68.11.2.4.16.1.4Columnpmlma10MonupRmonBytesCounterClientInputOverloadPortnread-onlycurrentBytes Counter Overload :This OID when set indicates a Bytes counter overload on client port
1.3.6.1.4.1.20044.68.11.2.4.32Tablepmlma10MonupRmonCrcErrorsCounterClientInputTablenot-accessiblecurrentList of pmlma10MonupRmonCrcErrorsCounterClientInput Article
1.3.6.1.4.1.20044.68.11.2.4.32.1Rowpmlma10MonupRmonCrcErrorsCounterClientInputEntrynot-accessiblecurrentRow definition for the pmlma10MonupRmonCrcErrorsCounterClientInput table
1.3.6.1.4.1.20044.68.11.2.4.32.1.1Columnpmlma10MonupRmonCrcErrorsCounterClientInputIndexread-onlycurrentIndex definition for the pmlma10MonupRmonCrcErrorsCounterClientInput table
1.3.6.1.4.1.20044.68.11.2.4.32.1.2Columnpmlma10MonupRmonCrcErrorsCounterClientInputValuePortnread-onlycurrentClient Input B1/CRC Errors :This counter is increased each time a B1/FCS error is detected on the client port <Help> This counter gives the number of B1/FCS Er…
1.3.6.1.4.1.20044.68.11.2.4.32.1.3Columnpmlma10MonupRmonCrcErrorsCounterClientInputErrorPortnread-onlycurrentB1/FCS Errors Counter Error :This OID when set indicates the B1/FCS Errors counter value is invalid on client port
1.3.6.1.4.1.20044.68.11.2.4.32.1.4Columnpmlma10MonupRmonCrcErrorsCounterClientInputOverloadPortnread-onlycurrentB1/FCS Errors Counter Overload :This OID when set indicates a B1/FCS Errors counter overload on client port
1.3.6.1.4.1.20044.68.11.2.4.48Tablepmlma10MonupRmonPacketsCounterClientInputTablenot-accessiblecurrentList of pmlma10MonupRmonPacketsCounterClientInput Article
1.3.6.1.4.1.20044.68.11.2.4.48.1Rowpmlma10MonupRmonPacketsCounterClientInputEntrynot-accessiblecurrentRow definition for the pmlma10MonupRmonPacketsCounterClientInput table
1.3.6.1.4.1.20044.68.11.2.4.48.1.1Columnpmlma10MonupRmonPacketsCounterClientInputIndexread-onlycurrentIndex definition for the pmlma10MonupRmonPacketsCounterClientInput table
1.3.6.1.4.1.20044.68.11.2.4.48.1.2Columnpmlma10MonupRmonPacketsCounterClientInputValuePortnread-onlycurrentClient Input Packets :This counter is increased each time a packet is received on the client port <Help> This counter gives the number of packets received on t…
1.3.6.1.4.1.20044.68.11.2.4.48.1.3Columnpmlma10MonupRmonPacketsCounterClientInputErrorPortnread-onlycurrentPackets Counter Error :This OID when set indicates the Packets counter value is invalid on client port
1.3.6.1.4.1.20044.68.11.2.4.48.1.4Columnpmlma10MonupRmonPacketsCounterClientInputOverloadPortnread-onlycurrentPackets Counter Overload :This OID when set indicates a Packets counter overload on client port
1.3.6.1.4.1.20044.68.11.2.4.64Tablepmlma10MonupRmonBroadcastCounterClientInputTablenot-accessiblecurrentList of pmlma10MonupRmonBroadcastCounterClientInput Article
1.3.6.1.4.1.20044.68.11.2.4.64.1Rowpmlma10MonupRmonBroadcastCounterClientInputEntrynot-accessiblecurrentRow definition for the pmlma10MonupRmonBroadcastCounterClientInput table
1.3.6.1.4.1.20044.68.11.2.4.64.1.1Columnpmlma10MonupRmonBroadcastCounterClientInputIndexread-onlycurrentIndex definition for the pmlma10MonupRmonBroadcastCounterClientInput table
1.3.6.1.4.1.20044.68.11.2.4.64.1.2Columnpmlma10MonupRmonBroadcastCounterClientInputValuePortnread-onlycurrentClient Input Broadcast Packets :This counter is increased each time a broadcast packet is received on the client port <Help> This counter gives the number of B…
1.3.6.1.4.1.20044.68.11.2.4.64.1.3Columnpmlma10MonupRmonBroadcastCounterClientInputErrorPortnread-onlycurrentBroadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on client port
1.3.6.1.4.1.20044.68.11.2.4.64.1.4Columnpmlma10MonupRmonBroadcastCounterClientInputOverloadPortnread-onlycurrentBroadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port
1.3.6.1.4.1.20044.68.11.2.4.80Tablepmlma10MonupRmonMulticastCounterClientInputTablenot-accessiblecurrentList of pmlma10MonupRmonMulticastCounterClientInput Article
1.3.6.1.4.1.20044.68.11.2.4.80.1Rowpmlma10MonupRmonMulticastCounterClientInputEntrynot-accessiblecurrentRow definition for the pmlma10MonupRmonMulticastCounterClientInput table
1.3.6.1.4.1.20044.68.11.2.4.80.1.1Columnpmlma10MonupRmonMulticastCounterClientInputIndexread-onlycurrentIndex definition for the pmlma10MonupRmonMulticastCounterClientInput table
1.3.6.1.4.1.20044.68.11.2.4.80.1.2Columnpmlma10MonupRmonMulticastCounterClientInputValuePortnread-onlycurrentClient Input Multicast Packets :This counter is increased each time a Multicast packet is received on the client port <Help> This counter gives the number of M…
1.3.6.1.4.1.20044.68.11.2.4.80.1.3Columnpmlma10MonupRmonMulticastCounterClientInputErrorPortnread-onlycurrentMulticast Counter Error :This OID when set indicates the Multicast counter value is invalid on client port
1.3.6.1.4.1.20044.68.11.2.4.80.1.4Columnpmlma10MonupRmonMulticastCounterClientInputOverloadPortnread-onlycurrentMulticast Counter Overload :This OID when set indicates a Multicast counter overload on client port
1.3.6.1.4.1.20044.68.11.2.4.96Tablepmlma10MonupRmonPauseFrameCounterClientInputTablenot-accessiblecurrentList of pmlma10MonupRmonPauseFrameCounterClientInput Article
1.3.6.1.4.1.20044.68.11.2.4.96.1Rowpmlma10MonupRmonPauseFrameCounterClientInputEntrynot-accessiblecurrentRow definition for the pmlma10MonupRmonPauseFrameCounterClientInput table
1.3.6.1.4.1.20044.68.11.2.4.96.1.1Columnpmlma10MonupRmonPauseFrameCounterClientInputIndexread-onlycurrentIndex definition for the pmlma10MonupRmonPauseFrameCounterClientInput table
1.3.6.1.4.1.20044.68.11.2.4.96.1.2Columnpmlma10MonupRmonPauseFrameCounterClientInputValuePortnread-onlycurrentClient Input Pause Frames :This counter is increased each time a Pause frame is received on the client port <Help> This counter gives the number of Pause frame…
1.3.6.1.4.1.20044.68.11.2.4.96.1.3Columnpmlma10MonupRmonPauseFrameCounterClientInputErrorPortnread-onlycurrentPause Counter Error :This OID when set indicates the Pause counter value is invalid on client port
1.3.6.1.4.1.20044.68.11.2.4.96.1.4Columnpmlma10MonupRmonPauseFrameCounterClientInputOverloadPortnread-onlycurrentPause Counter Overload :This OID when set indicates a Pause counter overload on client port
1.3.6.1.4.1.20044.68.11.2.4.224Tablepmlma10MondwRmonCrcErrorsCounterClientInputTablenot-accessiblecurrentList of pmlma10MondwRmonCrcErrorsCounterClientInput Article
1.3.6.1.4.1.20044.68.11.2.4.224.1Rowpmlma10MondwRmonCrcErrorsCounterClientInputEntrynot-accessiblecurrentRow definition for the pmlma10MondwRmonCrcErrorsCounterClientInput table
1.3.6.1.4.1.20044.68.11.2.4.224.1.1Columnpmlma10MondwRmonCrcErrorsCounterClientInputIndexread-onlycurrentIndex definition for the pmlma10MondwRmonCrcErrorsCounterClientInput table
1.3.6.1.4.1.20044.68.11.2.4.224.1.2Columnpmlma10MondwRmonCrcErrorsCounterClientInputValuePortnread-onlycurrentClient Output B1/CRC Errors :This counter is increased each time a B1/FCS error is detected on the output client port <Help> This counter gives the number of B…
1.3.6.1.4.1.20044.68.11.2.4.224.1.3Columnpmlma10MondwRmonCrcErrorsCounterClientInputErrorPortnread-onlycurrentOutput B1/FCS Errors Counter Error :This OID when set indicates the output B1/FCS Errors counter value is invalid on client port
1.3.6.1.4.1.20044.68.11.2.4.224.1.4Columnpmlma10MondwRmonCrcErrorsCounterClientInputOverloadPortnread-onlycurrentOutput B1/FCS Errors Counter Overload :This OID when set indicates an output B1/FCS Errors counter overload on client port
1.3.6.1.4.1.20044.68.11.2.4.240Tablepmlma10MondwRmonPacketsCounterClientInputTablenot-accessiblecurrentList of pmlma10MondwRmonPacketsCounterClientInput Article
1.3.6.1.4.1.20044.68.11.2.4.240.1Rowpmlma10MondwRmonPacketsCounterClientInputEntrynot-accessiblecurrentRow definition for the pmlma10MondwRmonPacketsCounterClientInput table
1.3.6.1.4.1.20044.68.11.2.4.240.1.1Columnpmlma10MondwRmonPacketsCounterClientInputIndexread-onlycurrentIndex definition for the pmlma10MondwRmonPacketsCounterClientInput table
1.3.6.1.4.1.20044.68.11.2.4.240.1.2Columnpmlma10MondwRmonPacketsCounterClientInputValuePortnread-onlycurrentClient Output Packets :This counter is increased each time a packet is transmitted on the client port. <Help> This counter gives the number of packets detected…
1.3.6.1.4.1.20044.68.11.2.4.240.1.3Columnpmlma10MondwRmonPacketsCounterClientInputErrorPortnread-onlycurrentOutput Packets Counter Error :This OID when set indicates the output Packets counter value is invalid on client port
1.3.6.1.4.1.20044.68.11.2.4.240.1.4Columnpmlma10MondwRmonPacketsCounterClientInputOverloadPortnread-onlycurrentOutput Packets Counter Overload :This OID when set indicates an output Packets counter overload on client port
Type Definitions
NameSyntaxStatusDescription
Pmlma10AdjustValueINTEGER { otxadjustvalue0(0), otxadjustvalue1(1), otxadjustvalue2(2), otxadjustvalue3(3), otxadjustvalue4(4), otxadjustvalue5(5), otxadjustvalue6(6), otxadjustvalue7(7), otxadjustvalue8(8), otxadjustvalue9(9), otxadjustvalue10(10) }currentDifferent values in Adjust mode on OTX-TLH on client and line ports
Pmlma10ClientIgnoreTimerINTEGER { ignoretimerclientvalue0(0), ignoretimerclientvalue1(1), ignoretimerclientvalue2(2), ignoretimerclientvalue3(3), ignoretimerclientvalue4(4), ignoretimerclientvalue5(5), ignoretimerclientvalue6(6), ignoretimerclientvalue7(7), ignoretimerclientvalue8(8), ignoretimerclientvalue9(9), ignoretimerclientvalue10(10) }currentDifferent values on the ignore timer on the client ports
Pmlma10ClientProtocolINTEGER { protocolclientvalue0(0), protocolclientvalue1(1), protocolclientvalue2(2), protocolclientvalue3(3), protocolclientvalue4(4), protocolclientvalue5(5), protocolclientvalue6(6), protocolclientvalue7(7), protocolclientvalue8(8) }currentDifferent values on the protocol on the client ports
Pmlma10DccModeINTEGER { dccNo(0), dccLine1(1), dccLine2(2) }currentMode for DCC
Pmlma10MultiRateINTEGER { rate100Mhz(0), rate250Mhz(1), rate500Mhz(2), rate1Ghz(3) }currentdifferent rate for a client port
Pmlma10OrxChannelINTEGERcurrentChannel selection on transceiver Rx line ports
Pmlma10OtxChannelINTEGERcurrentChannel selection on transceiver Tx line ports
Pmlma10OtxGridINTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50) }currentDifferent grids on OTX-TLH on client and line ports
Pmlma10OtxModeINTEGER { otx80mode(1), otx60mode(2), otxadjustmode(4) }currentDifferent modes on OTX-TLH on client and line ports
Pmlma10ProtocolModeINTEGER { protocolmodevalue0(0), protocolmodevalue1(1), protocolmodevalue2(2), protocolmodevalue3(3) }currentDifferent values on the protocol mode