MIB Viewer

EKINOPS-Pmo10010-MIB

933 objects
Creation.
OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.76IdentitymodulePmo10010Creation.
1.3.6.1.4.1.20044.76.2Nodepmo10010alarms
1.3.6.1.4.1.20044.76.2.1Nodepmo10010AlmOther
1.3.6.1.4.1.20044.76.2.1.1Nodepmo10010AlmOtherNurg
1.3.6.1.4.1.20044.76.2.1.1.2Nodepmo10010AlmsynthAlm2
1.3.6.1.4.1.20044.76.2.1.1.2.1Scalarpmo10010AlmConfTableSaveread-onlycurrentPM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> infor…
1.3.6.1.4.1.20044.76.2.1.1.2.2Scalarpmo10010AlmInvUploadread-onlycurrentInventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> informationalStatus(1000) <Alarmtype> ot…
1.3.6.1.4.1.20044.76.2.1.1.2.3Scalarpmo10010AlmConfTableLoadread-onlycurrentPM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> informationalStat…
1.3.6.1.4.1.20044.76.2.1.1.2.4Scalarpmo10010AlmCorrelatOffread-onlycurrentNot Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> informationalStatus(1000) <Alarmtype…
1.3.6.1.4.1.20044.76.2.1.1.2.5Scalarpmo10010AlmMaintenanceOnread-onlycurrentMaintenance Mode :This OID indicates that the RM is in maintenance mode. <Help> This alarm indicates that the maintenance mode is enabled on the PM <Condtype> …
1.3.6.1.4.1.20044.76.2.1.2Nodepmo10010AlmOtherUrg
1.3.6.1.4.1.20044.76.2.1.3Nodepmo10010AlmOtherCrit
1.3.6.1.4.1.20044.76.2.1.3.0Nodepmo10010AlmsynthAlm0
1.3.6.1.4.1.20044.76.2.1.3.0.2Scalarpmo10010AlmFailFanread-onlycurrentFan Fail :This OID is at 1 when any fail occurs on the fan tray <Help> This alarm indicates that the Fan tray module is in a failure condition <Condtype> FAIL_…
1.3.6.1.4.1.20044.76.2.1.3.0.9Scalarpmo10010AlmModGlobFailread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the RM <Help> This alarm is set on detection of a failure originating from the equip…
1.3.6.1.4.1.20044.76.2.1.3.0.15Scalarpmo10010AlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.76.2.1.3.0.16Scalarpmo10010AlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.76.2.1.3.40Nodepmo10010AlmclientModuleState
1.3.6.1.4.1.20044.76.2.1.3.40.1Scalarpmo10010AlmCfpInitializeread-onlycurrentClient Trscv Initialize :This OID indicates the Client Trscv initialization is in progress <Help> Status indicating the Client Trscv initialization is in progr…
1.3.6.1.4.1.20044.76.2.1.3.40.2Scalarpmo10010AlmCfpLowPowerread-onlycurrentClient Trscv Low Power :This OID indicates the Client Trscv is in low power state <Help> Status indicating the Client Trscv is in low power state <Condtype> CF…
1.3.6.1.4.1.20044.76.2.1.3.40.3Scalarpmo10010AlmCfpHighPowerUpread-onlycurrentClient Trscv High Power Up :This OID indicates the Client Trscv is leaving Low Power state <Help> Status indicating the Client Trscv is leaving Low Power state…
1.3.6.1.4.1.20044.76.2.1.3.40.4Scalarpmo10010AlmCfpTxOffread-onlycurrentClient Trscv Laser Shutdown :This OID indicates the Client Trscv Laser is OFF <Help> Status indicating the Client Trscv Laser is OFF <Condtype> CFP_TX_OFF <Pro…
1.3.6.1.4.1.20044.76.2.1.3.40.5Scalarpmo10010AlmCfpTxTurnOnread-onlycurrentClient Trscv Laser Turn On :This OID indicates the Client Trscv is turning on its laser <Help> Status indicating the Client Trscv is turning on its laser <Cond…
1.3.6.1.4.1.20044.76.2.1.3.40.6Scalarpmo10010AlmCfpReadyread-onlycurrentClient Trscv Ready :This OID indicates the Client Trscv is ready to operate <Help> Status indicating the Client Trscv is ready to operate <Condtype> CFP_READY …
1.3.6.1.4.1.20044.76.2.1.3.40.7Scalarpmo10010AlmCfpFaultread-onlycurrentClient Trscv Fault :This OID indicates the Client Trscv is in Fault state <Help> Status indicating the Client Trscv is in Fault state <Condtype> CFP_FAULT <Pro…
1.3.6.1.4.1.20044.76.2.1.3.40.8Scalarpmo10010AlmCfpTxTurnOffread-onlycurrentClient Trscv Laser Turn Off :This OID indicates the Client Trscv is turning off its laser <Help> Status indicating the Client Trscv is turning off its laser <C…
1.3.6.1.4.1.20044.76.2.1.3.40.9Scalarpmo10010AlmCfpHighPowerDownread-onlycurrentClient Trscv High Power Down :This OID indicates the Client Trscv is entering Low Power state <Help> Status indicating the Client Trscv is entering Low Power s…
1.3.6.1.4.1.20044.76.2.1.3.41Nodepmo10010AlmclientModuleGeneralStatus
1.3.6.1.4.1.20044.76.2.1.3.41.4Scalarpmo10010AlmCfpOutOfAlignmentread-onlycurrentClient Trscv Out Of Alignment :This OID indicates an Out of alignment on the Client Trscv Host Interface <Help> Alarm indicating an Out of alignment on the Cli…
1.3.6.1.4.1.20044.76.2.1.3.41.5Scalarpmo10010AlmCfpRxNetworkLolread-onlycurrentClient Trscv Rx Network Loss Of Lock :This OID indicates of Loss of Lock is dected on the Client Trscv Rx Network interface <Help> Alarm indicating of Loss of …
1.3.6.1.4.1.20044.76.2.1.3.41.6Scalarpmo10010AlmCfpRxLosread-onlycurrentClient Trscv Loss Of Signal :This OID indicates a Loss of Signal is detected on the Client Trscv <Help> Alarm indicating a Loss of Signal is detected on the Cl…
1.3.6.1.4.1.20044.76.2.1.3.41.7Scalarpmo10010AlmCfpTxHostLolread-onlycurrentClient Trscv Tx Host Loss Of Lock :This OID indicates of Loss of Lock is detected on the Client Trscv Tx Host interface <Help> Alarm indicating of Loss of Lock…
1.3.6.1.4.1.20044.76.2.1.3.41.8Scalarpmo10010AlmCfpTxLosfread-onlycurrentClient Trscv Loss Of Signal Functionality :This OID indicates a Loss of Signal functionality is detected on the Client Trscv <Help> Alarm indicating a Loss of …
1.3.6.1.4.1.20044.76.2.1.3.41.9Scalarpmo10010AlmCfpTxCmuLolread-onlycurrentClient Trscv CMU Loss Of Lock :This OID indicates a Clock Multiplier Unit Loss of Lock is detected on the Client Trscv <Help> Alarm indicating a Clock Multipli…
1.3.6.1.4.1.20044.76.2.1.3.41.10Scalarpmo10010AlmCfpTxJitterPllLolread-onlycurrentClient Trscv Tx Jitter PLL Loss Of Lock :This OID indicates a Tx Jitter PLL Loss of Lock is dtected on the Client Trscv <Help> Alarm indicating a Tx Jitter PLL…
1.3.6.1.4.1.20044.76.2.1.3.41.11Scalarpmo10010AlmCfpLossOfRefclkread-onlycurrentClient Trscv Loss Of Ref Clock :This OID indicates a Loss of Reference clock is detected on the Client Trscv <Help> Alarm indicating a Loss of Reference clock …
1.3.6.1.4.1.20044.76.2.1.3.41.14Scalarpmo10010AlmCfpHwInterlockread-onlycurrentClient Trscv Hardware Interlock :This OID indicates the Client Trscv power is higher than the cooling capacity <Help> Alarm indicating the Client Trscv power i…
1.3.6.1.4.1.20044.76.2.1.3.42Nodepmo10010AlmclientGlobalAlarmSummary
1.3.6.1.4.1.20044.76.2.1.3.42.1Scalarpmo10010AlmCfpSoftGlobAlarmTestread-onlycurrentClient Trscv Global Alarm SW Test :This OID indicates the Client Trscv Global Alarm This OID is raised by SW request for test purpose <Help> Status indicating …
1.3.6.1.4.1.20044.76.2.1.3.42.7Scalarpmo10010AlmCfpNetworkLaneAlarmWarning2read-onlycurrentClient Trscv Network Alarm And Warning 2 :This OID indicates at least one DDM is detected on the Client Trscv Network Interface <Help> Synthesis alarm indicati…
1.3.6.1.4.1.20044.76.2.1.3.42.8Scalarpmo10010AlmCfpModuleStateread-onlycurrentClient Trscv Module State :This OID indicates the Client Trscv module state <Help> Synthesis alarm indicating the Client Trscv module state <Condtype> CFP_MODU…
1.3.6.1.4.1.20044.76.2.1.3.42.9Scalarpmo10010AlmCfpModuleGeneralStatusread-onlycurrentClient Trscv General Status :This OID indicates the Client Trscv module general status <Help> Synthesis alarm indicating the Client Trscv module general status…
1.3.6.1.4.1.20044.76.2.1.3.42.10Scalarpmo10010AlmCfpModuleFaultread-onlycurrentClient Trscv Module Fault :This OID indicates at least one Fault is detected on the Client Trscv module <Help> Synthesis alarm indicating at least one Fault is…
1.3.6.1.4.1.20044.76.2.1.3.42.11Scalarpmo10010AlmCfpModuleAlarmWarning1read-onlycurrentClient Trscv Module Alarm And Warning 1 :This OID indicates at least one DDM This OID is detected on the Client Trscv module <Help> Synthesis alarm indicating …
1.3.6.1.4.1.20044.76.2.1.3.42.12Scalarpmo10010AlmCfpModuleAlarmWarning2read-onlycurrentClient Trscv Module Alarm And Warning 2 :This OID indicates at least one DDM is detected on the Client Trscv module <Help> Synthesis alarm indicating at least …
1.3.6.1.4.1.20044.76.2.1.3.42.13Scalarpmo10010AlmCfpNetworkLaneAlarmWarning1read-onlycurrentClient Trscv Network Alarm And Warning 1 :This OID indicates at least one DDM is detected on the Client Trscv Network Interface <Help> Synthesis alarm indicati…
1.3.6.1.4.1.20044.76.2.1.3.42.14Scalarpmo10010AlmCfpNetworkLaneFaultStatusread-onlycurrentClient Trscv Network Fault And Status :This OID indicates at least one Fault or Status is detected on the Client Trscv Network Interface <Help> Synthesis alarm…
1.3.6.1.4.1.20044.76.2.1.3.42.15Scalarpmo10010AlmCfpHostLaneFaultStatusread-onlycurrentClient Trscv Host Fault And Status :This OID indicates at least one Fault or Status is detected on the Client Trscv Host Interface <Help> Synthesis alarm indic…
1.3.6.1.4.1.20044.76.2.1.3.42.16Scalarpmo10010AlmCfpGlobAlarmAssertionread-onlycurrentClient Trscv Global Alarm :This OID indicates at least one Fault or Status is detected on the Client Trscv module <Help> Synthesis alarm indicating at least on…
1.3.6.1.4.1.20044.76.2.1.3.46Nodepmo10010AlmmsaModuleState
1.3.6.1.4.1.20044.76.2.1.3.46.1Scalarpmo10010AlmMsaInitializeread-onlycurrentLine Trscv Initialize :This OID indicates the Line Trscv initialization is in progress <Help> Status indicating the Line Trscv initialization is in progress <C…
1.3.6.1.4.1.20044.76.2.1.3.46.2Scalarpmo10010AlmMsaLowPowerread-onlycurrentLine Trscv Low Power :This OID indicates the Line Trscv is in low power state <Help> Status indicating the Line Trscv is in low power state <Condtype> MSA_LOW_…
1.3.6.1.4.1.20044.76.2.1.3.46.3Scalarpmo10010AlmMsaHighPowerUpread-onlycurrentLine Trscv High Power Up :This OID indicates the Line Trscv is leaving Low Power state <Help> Status indicating the Line Trscv is leaving Low Power state <Cond…
1.3.6.1.4.1.20044.76.2.1.3.46.4Scalarpmo10010AlmMsaTxOffread-onlycurrentLine Trscv Laser Shutdown :This OID indicates the Line Trscv Laser is OFF <Help> Status indicating the Line Trscv Laser is OFF <Condtype> MSA_TX_OFF <Probcause…
1.3.6.1.4.1.20044.76.2.1.3.46.5Scalarpmo10010AlmMsaTxTurnOnread-onlycurrentLine Trscv Laser Turn On :This OID indicates the Line Trscv is turning on its laser <Help> Status indicating the Line Trscv is turning on its laser <Condtype> …
1.3.6.1.4.1.20044.76.2.1.3.46.6Scalarpmo10010AlmMsaReadyread-onlycurrentLine Trscv Ready :This OID indicates the Line Trscv is ready to operate <Help> Status indicating the Line Trscv is ready to operate <Condtype> MSA_READY <Probc…
1.3.6.1.4.1.20044.76.2.1.3.46.7Scalarpmo10010AlmMsaFaultread-onlycurrentLine Trscv Fault :This OID indicates the Line Trscv is in Fault state <Help> Status indicating the Line Trscv is in Fault state <Condtype> MSA_FAULT <Probcause…
1.3.6.1.4.1.20044.76.2.1.3.46.8Scalarpmo10010AlmMsaTxTurnOffread-onlycurrentLine Trscv Laser Turn Off :This OID indicates the Line Trscv is turning off its laser <Help> Status indicating the Line Trscv is turning off its laser <Condtyp…
1.3.6.1.4.1.20044.76.2.1.3.46.9Scalarpmo10010AlmMsaHighPowerDownread-onlycurrentLine Trscv High Power Down :This OID indicates the Line Trscv is entering Low Power state <Help> Status indicating the Line Trscv is entering Low Power state <…
1.3.6.1.4.1.20044.76.2.1.3.47Nodepmo10010AlmmsaModuleGeneralStatus
1.3.6.1.4.1.20044.76.2.1.3.47.4Scalarpmo10010AlmMsaOutOfAlignmentread-onlycurrentLine Trscv Out Of Alignment :This OID indicates an Out of alignment on the Line Trscv Host Interface <Help> Alarm indicating an Out of alignment on the Line Tr…
1.3.6.1.4.1.20044.76.2.1.3.47.5Scalarpmo10010AlmMsaRxNetworkLolread-onlycurrentLine Trscv Rx Network Loss Of Lock :This OID indicates of Loss of Lock is detected on the Line Trscv Rx Network interface <Help> Alarm indicating of Loss of Lo…
1.3.6.1.4.1.20044.76.2.1.3.47.6Scalarpmo10010AlmMsaRxLosread-onlycurrentLine Trscv Loss Of Signal :This OID indicates a Loss of Signal is detected on the Line Trscv <Help> Alarm indicating a Loss of Signal is detected on the Line T…
1.3.6.1.4.1.20044.76.2.1.3.47.7Scalarpmo10010AlmMsaTxHostLolread-onlycurrentLine Trscv Tx Host Loss Of Lock :This OID indicates of Loss of Lock is detected on the Line Trscv Tx Host interface <Help> Alarm indicating of Loss of Lock is …
1.3.6.1.4.1.20044.76.2.1.3.47.8Scalarpmo10010AlmMsaTxLosfread-onlycurrentLine Trscv Loss Of Signal Functionality :This OID indicates a Loss of Signal functionality is detected on the Line Trscv <Help> Alarm indicating a Loss of Sign…
1.3.6.1.4.1.20044.76.2.1.3.47.9Scalarpmo10010AlmMsaTxCmuLolread-onlycurrentLine Trscv CMU Loss Of Lock :This OID indicates a Clock Multiplier Unit Loss of Lock is detected on the Line Trscv <Help> Alarm indicating a Clock Multiplier U…
1.3.6.1.4.1.20044.76.2.1.3.47.10Scalarpmo10010AlmMsaTxJitterPllLolread-onlycurrentLine Trscv Tx Jitter PLL Loss Of Lock :This OID indicates a Tx Jitter PLL Loss of Lock is detected on the Line Trscv <Help> Alarm indicating a Tx Jitter PLL Lo…
1.3.6.1.4.1.20044.76.2.1.3.47.11Scalarpmo10010AlmMsaLossOfRefclkread-onlycurrentLine Trscv Loss Of Ref Clock :This OID indicates a Loss of Reference clock is detected on the Line Trscv <Help> Alarm indicating a Loss of Reference clock is d…
1.3.6.1.4.1.20044.76.2.1.3.47.14Scalarpmo10010AlmMsaHwInterlockread-onlycurrentLine Trscv Hardware Interlock :This OID indicates the Line Trscv power is higher than the cooling capacity <Help> Alarm indicating the Line Trscv power is high…
1.3.6.1.4.1.20044.76.2.1.3.48Nodepmo10010AlmmsaGlobalAlarmSummary
1.3.6.1.4.1.20044.76.2.1.3.48.1Scalarpmo10010AlmMsaSoftGlobAlarmTestread-onlycurrentLine Trscv Global Alarm SW Test :This OID indicates the Line Trscv Global alarm This OID is raised by SW request for test purpose <Help> Status indicating the …
1.3.6.1.4.1.20044.76.2.1.3.48.6Scalarpmo10010AlmMsaNetworkHostAlarmStatusread-onlycurrentLine Trscv Network/Host Alarm Status :This OID indicates the state of the Network and Host interface of the Line Trscv <Help> Synthesis alarm indicating the al…
1.3.6.1.4.1.20044.76.2.1.3.48.7Scalarpmo10010AlmMsaNetworkLaneAlarmWarning2read-onlycurrentLine Trscv Network Alarm And Warning 2 :This OID indicates at least one DDM This OID is detected on the Line Trscv Network Interface <Help> Synthesis alarm ind…
1.3.6.1.4.1.20044.76.2.1.3.48.8Scalarpmo10010AlmMsaModuleStateread-onlycurrentLine Trscv Module State :This OID indicates the Line Trscv module state <Help> Synthesis alarm indicating the Line Trscv module state <Condtype> MSA_MODULE_STA…
1.3.6.1.4.1.20044.76.2.1.3.48.9Scalarpmo10010AlmMsaModuleGeneralStatusread-onlycurrentLine Trscv General Status :This OID indicates the Line Trscv module general <Help> Synthesis alarm indicating the Line Trscv module general status <Condtype> M…
1.3.6.1.4.1.20044.76.2.1.3.48.10Scalarpmo10010AlmModuleFaultread-onlycurrentLine Trscv Module Fault :This OID indicates at least one Fault is detected on the Line Trscv module <Help> Synthesis alarm indicating at least one Fault is det…
1.3.6.1.4.1.20044.76.2.1.3.48.11Scalarpmo10010AlmMsaModuleAlarmWarning1read-onlycurrentLine Trscv Module Alarm And Warning 1 :This OID indicates at least one DDM is detected on the Line Trscv module <Help> Synthesis alarm indicating at least one …
1.3.6.1.4.1.20044.76.2.1.3.48.12Scalarpmo10010AlmMsaModuleAlarmWarning2read-onlycurrentLine Trscv Module Alarm And Warning 2 :This OID indicates at least one DDM is detected on the Line Trscv module <Help> Synthesis alarm indicating at least one …
1.3.6.1.4.1.20044.76.2.1.3.48.13Scalarpmo10010AlmMsaNetworkLaneAlarmWarning1read-onlycurrentLine Trscv Network Alarm And Warning 1 :This OID indicates at least one DDM is detected on the Line Trscv Network Interface <Help> Synthesis alarm indicating a…
1.3.6.1.4.1.20044.76.2.1.3.48.14Scalarpmo10010AlmMsaNetworkLaneFaultStatusread-onlycurrentLine Trscv Network Fault And Status :This OID indicates at least one Fault or Status is detected on the Line Trscv Network Interface <Help> Synthesis alarm ind…
1.3.6.1.4.1.20044.76.2.1.3.48.15Scalarpmo10010AlmMsaHostLaneFaultStatusread-onlycurrentLine Trscv Host Fault And Status :This OID indicates at least one Fault or Status is detected on the Line Trscv Host Interface <Help> Synthesis alarm indicatin…
1.3.6.1.4.1.20044.76.2.1.3.48.16Scalarpmo10010AlmMsaGlobAlarmAssertionread-onlycurrentLine Trscv Global Alarm :This OID indicates at least one Fault or Status is detected on the Line Trscv module <Help> Synthesis alarm indicating at least one Al…
1.3.6.1.4.1.20044.76.2.1.3.49Nodepmo10010AlmmsaNetworkTxAlignment
1.3.6.1.4.1.20044.76.2.1.3.49.12Scalarpmo10010AlmNetTxTimingFaultread-onlycurrentLine Trscv Network Tx Timing Fault :This OID indicates a Tx Timing Fault is detected on the Line Trscv Network interface <Help> Alarm indicating a Tx Timing Fa…
1.3.6.1.4.1.20044.76.2.1.3.49.13Scalarpmo10010AlmNetTxReferenceClockFaultread-onlycurrentLine Trscv Network Tx Ref Clock Fault :This OID indicates a Tx Reference Clock Fault is detected on the Line Trscv Network interface <Help> Alarm indicating a …
1.3.6.1.4.1.20044.76.2.1.3.49.14Scalarpmo10010AlmNetTxCmuLockFaultread-onlycurrentLine Trscv Network Tx CMU Lock Fault :This OID indicates a Tx Clock Multiplier Unit Lock Fault is detected on the Line Trscv Network interface <Help> Alarm ind…
1.3.6.1.4.1.20044.76.2.1.3.49.15Scalarpmo10010AlmNetTxOutOfAlignmentread-onlycurrentLine Trscv Network Tx Out Of Alignment :This OID indicates a Tx Out of Alignment is detected on the Line Trscv Network interface <Help> Alarm indicating a Tx O…
1.3.6.1.4.1.20044.76.2.1.3.49.16Scalarpmo10010AlmNetTxLossOfAlignmentread-onlycurrentLine Trscv Network Tx Loss Of Alignment :This OID indicates a Tx Loss of Alignment is detected on the Line Trscv Network interface <Help> Alarm indicating a Tx…
1.3.6.1.4.1.20044.76.2.1.3.50Nodepmo10010AlmmsaNetworkRxAlignment
1.3.6.1.4.1.20044.76.2.1.3.50.12Scalarpmo10010AlmNetRxTimingFaultread-onlycurrentLine Trscv Network Rx Timing Fault :This OID indicates a Rx Timing Fault is detected on the Line Trscv Network interface <Help> Alarm indicating a Rx Timing Fa…
1.3.6.1.4.1.20044.76.2.1.3.50.13Scalarpmo10010AlmNetRxOutOfAlignmentread-onlycurrentLine Trscv Network Rx Out Of Alignment :This OID indicates a Rx Out of Alignment is detected on the Line Trscv Network interface <Help> Alarm indicating a Rx O…
1.3.6.1.4.1.20044.76.2.1.3.50.14Scalarpmo10010AlmNetRxLossOfAlignmentread-onlycurrentLine Trscv Network Rx Loss Of Alignment :This OID indicates a Rx Loss of Alignment is detected on the Line Trscv Network interface <Help> Alarm indicating a Rx…
1.3.6.1.4.1.20044.76.2.1.3.50.15Scalarpmo10010AlmNetRxModemLockFaultread-onlycurrentLine Trscv Network Rx Modem Lock Fault :This OID indicates a Rx Modem Lock Fault is detected on the Line Trscv Network interface <Help> Alarm indicating a Rx M…
1.3.6.1.4.1.20044.76.2.1.3.50.16Scalarpmo10010AlmNetRxModemSyncDetectFaultread-onlycurrentLine Trscv Network Rx Modem Sync Detect Fault :This OID indicates a Rx Modem Synchronisation Detection Fault is detected on the Line Trscv Network interface <H…
1.3.6.1.4.1.20044.76.2.1.3.51Nodepmo10010AlmmsaNetworkHostNetworkAlarmSummary
1.3.6.1.4.1.20044.76.2.1.3.51.11Scalarpmo10010AlmNetworkTxAlignmentread-onlycurrentLine Trscv Network Tx Alignment :This OID indicates a Tx Alignment Fault is detected on the Line Trscv Network interface <Help> Synthesis Alarm indicating a Tx…
1.3.6.1.4.1.20044.76.2.1.3.51.12Scalarpmo10010AlmNetworkRxAlignmentread-onlycurrentLine Trscv Network Rx Alignment :This OID indicates a Rx Alignment Fault is detected on the Line Trscv Network interface <Help> Synthesis Alarm indicating a Rx…
1.3.6.1.4.1.20044.76.2.1.3.51.13Scalarpmo10010AlmNetworkRxOtnread-onlycurrentLine Trscv Network Rx OTN :This OID indicates a Rx OTN Fault is detected on the Line Trscv Network interface <Help> Synthesis Alarm indicating a Rx OTN Fault i…
1.3.6.1.4.1.20044.76.2.1.3.51.14Scalarpmo10010AlmHostRxAlignmentread-onlycurrentLine Trscv Host Rx Alignment :This OID indicates a Rx Alignment Fault is detected on the Line Trscv Host interface <Help> Synthesis Alarm indicating a Rx Align…
1.3.6.1.4.1.20044.76.2.1.3.51.15Scalarpmo10010AlmHostTxAlignmentread-onlycurrentLine Trscv Host Tx Alignment :This OID indicates a Tx Alignment Fault is detected on the Line Trscv Host interface <Help> Synthesis Alarm indicating a Tx Align…
1.3.6.1.4.1.20044.76.2.1.3.51.16Scalarpmo10010AlmHostTxOtnStatusread-onlycurrentLine Trscv Host Tx OTN :This OID indicates a Tx OTN Fault is detected on the Line Trscv Host interface <Help> Synthesis Alarm indicating a Tx OTN Fault is dete…
1.3.6.1.4.1.20044.76.2.1.3.52Nodepmo10010AlmmsaHostTxAlignment
1.3.6.1.4.1.20044.76.2.1.3.52.13Scalarpmo10010AlmHostTxDeskewLockFaultread-onlycurrentLine Trscv Host Tx Deskew Lock Fault :This OID indicates a Tx Deskew Lock Fault is detected on the Line Trscv Host interface <Help> Alarm indicating a Tx Deske…
1.3.6.1.4.1.20044.76.2.1.3.52.14Scalarpmo10010AlmHostTxOutOfAlignmentread-onlycurrentLine Trscv Host Tx Out Of Alignment :This OID indicates a Tx Out of Alignment is detected on the Line Trscv Host interface <Help> Alarm indicating a Tx Out of …
1.3.6.1.4.1.20044.76.2.1.3.52.15Scalarpmo10010AlmHostTxLossOfAlignmentread-onlycurrentLine Trscv Host Tx Loss Of Alignment :This OID indicates a Tx Loss of Alignment is detected on the Line Trscv Host interface <Help> Alarm indicating a Tx Loss …
1.3.6.1.4.1.20044.76.2.1.3.52.16Scalarpmo10010AlmHostTxCdrLockFaultread-onlycurrentLine Trscv Host Tx CDR Lock Fault :This OID indicates a Tx Clock Data Recovery Lock Fault is detected on the Line Trscv Host interface <Help> Alarm indicating …
1.3.6.1.4.1.20044.76.2.1.3.53Nodepmo10010AlmmsaHostRxAlignment
1.3.6.1.4.1.20044.76.2.1.3.53.14Scalarpmo10010AlmHostRxCmuLockFaultread-onlycurrentLine Trscv Host Rx CMU Lock Fault :This OID indicates a Rx Clock Multiplier Unit Lock Fault is detected on the Line Trscv Host interface <Help> Alarm indicatin…
1.3.6.1.4.1.20044.76.2.1.3.53.15Scalarpmo10010AlmHostRxOutOfAlignmentread-onlycurrentLine Trscv Host Rx Out Of Alignment :This OID indicates a Rx Out of Alignment is detected on the Line Trscv Host interface <Help> Alarm indicating a Rx Out of …
1.3.6.1.4.1.20044.76.2.1.3.53.16Scalarpmo10010AlmHostRxLossOfAlignmentread-onlycurrentLine Trscv Host Rx Loss Of Alignment :This OID indicates a Rx Loss of Alignment is detected on the Line Trscv Host interface <Help> Alarm indicating a Rx Loss …
1.3.6.1.4.1.20044.76.2.2Nodepmo10010AlmClient
1.3.6.1.4.1.20044.76.2.2.1Nodepmo10010AlmClientNurg
1.3.6.1.4.1.20044.76.2.2.1.56Tablepmo10010AlmclientNetworkLaneAlarmWarningTablenot-accessiblecurrentList of pmo10010AlmclientNetworkLaneAlarmWarning Article
1.3.6.1.4.1.20044.76.2.2.1.56.1Rowpmo10010AlmclientNetworkLaneAlarmWarningEntrynot-accessiblecurrentRow definition for the pmo10010AlmclientNetworkLaneAlarmWarning table
1.3.6.1.4.1.20044.76.2.2.1.56.1.1Columnpmo10010AlmclientNetworkLaneAlarmWarningIndexread-onlycurrentIndex definition for the pmo10010AlmclientNetworkLaneAlarmWarning table
1.3.6.1.4.1.20044.76.2.2.1.56.1.2Columnpmo10010AlmClientRxPowerLowAlarmPortnread-onlycurrentClient Trscv Rx Power Low Alarm :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indic…
1.3.6.1.4.1.20044.76.2.2.1.56.1.3Columnpmo10010AlmClientRxPowerLowWarningPortnread-onlycurrentClient Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning i…
1.3.6.1.4.1.20044.76.2.2.1.56.1.4Columnpmo10010AlmClientRxPowerHighWarningPortnread-onlycurrentClient Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning…
1.3.6.1.4.1.20044.76.2.2.1.56.1.5Columnpmo10010AlmClientRxPowerHighAlarmPortnread-onlycurrentClient Trscv Rx Power High Alarm :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm ind…
1.3.6.1.4.1.20044.76.2.2.1.56.1.6Columnpmo10010AlmLaserTempLowAlarmPortnread-onlycurrentClient Trscv Laser Temp Low Alarm :This OID indicates that the Trscv Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help> Ala…
1.3.6.1.4.1.20044.76.2.2.1.56.1.7Columnpmo10010AlmClientLaserTempLowWarningPortnread-onlycurrentClient Trscv Laser Temp Low Warning :This OID indicates that the Trscv Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help> W…
1.3.6.1.4.1.20044.76.2.2.1.56.1.8Columnpmo10010AlmClientLaserTempHighWarningPortnread-onlycurrentClient Trscv Laser Temp High Warning :This OID indicates that the Trscv Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Help>…
1.3.6.1.4.1.20044.76.2.2.1.56.1.9Columnpmo10010AlmClientLaserTempHighAlarmPortnread-onlycurrentClient Trscv Laser Temp High Alarm :This OID indicates that the Trscv Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Help> A…
1.3.6.1.4.1.20044.76.2.2.1.56.1.10Columnpmo10010AlmClientTxPowerLowAlarmPortnread-onlycurrentClient Trscv Tx Power Low Alarm :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indi…
1.3.6.1.4.1.20044.76.2.2.1.56.1.11Columnpmo10010AlmClientTxPowerLowWarningPortnread-onlycurrentClient Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.76.2.2.1.56.1.12Columnpmo10010AlmClientTxPowerHighWarningPortnread-onlycurrentClient Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.76.2.2.1.56.1.13Columnpmo10010AlmClientTxPowerHighAlarmPortnread-onlycurrentClient Trscv Tx Power High Alarm :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm in…
1.3.6.1.4.1.20044.76.2.2.1.56.1.14Columnpmo10010AlmClientBiasLowAlarmPortnread-onlycurrentClient Trscv Bias Low Alarm :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in…
1.3.6.1.4.1.20044.76.2.2.1.56.1.15Columnpmo10010AlmClientBiasLowWarningPortnread-onlycurrentClient Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.76.2.2.1.56.1.16Columnpmo10010AlmClientBiasHighWarningPortnread-onlycurrentClient Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warn…
1.3.6.1.4.1.20044.76.2.2.1.56.1.17Columnpmo10010AlmClientBiasHighAlarmPortnread-onlycurrentClient Trscv Bias High Alarm :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.76.2.2.1.232Tablepmo10010AlmclientSfpWarnDdmTablenot-accessiblecurrentList of pmo10010AlmclientSfpWarnDdm Article
1.3.6.1.4.1.20044.76.2.2.1.232.1Rowpmo10010AlmclientSfpWarnDdmEntrynot-accessiblecurrentRow definition for the pmo10010AlmclientSfpWarnDdm table
1.3.6.1.4.1.20044.76.2.2.1.232.1.1Columnpmo10010AlmclientSfpWarnDdmIndexread-onlycurrentIndex definition for the pmo10010AlmclientSfpWarnDdm table
1.3.6.1.4.1.20044.76.2.2.1.232.1.2Columnpmo10010AlmTxPwLowWngPortnread-onlycurrentClient Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.76.2.2.1.232.1.3Columnpmo10010AlmTxPwrHighWngPortnread-onlycurrentClient Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.76.2.2.1.232.1.4Columnpmo10010AlmTxBiasLowWngPortnread-onlycurrentClient Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.76.2.2.1.232.1.5Columnpmo10010AlmTxBiasHighWngPortnread-onlycurrentClient Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warn…
1.3.6.1.4.1.20044.76.2.2.1.232.1.6Columnpmo10010AlmVccLowWngPortnread-onlycurrentClient Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Warn…
1.3.6.1.4.1.20044.76.2.2.1.232.1.7Columnpmo10010AlmVccHighWngPortnread-onlycurrentClient Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Wa…
1.3.6.1.4.1.20044.76.2.2.1.232.1.8Columnpmo10010AlmTempLowWngPortnread-onlycurrentClient Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indic…
1.3.6.1.4.1.20044.76.2.2.1.232.1.9Columnpmo10010AlmTempHighWngPortnread-onlycurrentClient Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning ind…
1.3.6.1.4.1.20044.76.2.2.1.232.1.16Columnpmo10010AlmRxPwrLowWngPortnread-onlycurrentClient Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning i…
1.3.6.1.4.1.20044.76.2.2.1.232.1.17Columnpmo10010AlmRxPwrHighWngPortnread-onlycurrentClient Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning…
1.3.6.1.4.1.20044.76.2.2.2Nodepmo10010AlmClientUrg
1.3.6.1.4.1.20044.76.2.2.2.72Tablepmo10010AlmclientNetworkLaneFaultTablenot-accessiblecurrentList of pmo10010AlmclientNetworkLaneFault Article
1.3.6.1.4.1.20044.76.2.2.2.72.1Rowpmo10010AlmclientNetworkLaneFaultEntrynot-accessiblecurrentRow definition for the pmo10010AlmclientNetworkLaneFault table
1.3.6.1.4.1.20044.76.2.2.2.72.1.1Columnpmo10010AlmclientNetworkLaneFaultIndexread-onlycurrentIndex definition for the pmo10010AlmclientNetworkLaneFault table
1.3.6.1.4.1.20044.76.2.2.2.72.1.4Columnpmo10010AlmClientLaneRxFifoErrorPortnread-onlycurrentClient Network Lane Rx FIFO Error :This OID indicates a Rx FIFO Error on the Client Trscv Network Lane <Help> Alarm indicating a Rx FIFO Error on the Client Tr…
1.3.6.1.4.1.20044.76.2.2.2.72.1.5Columnpmo10010AlmClientLaneRxLolPortnread-onlycurrentClient Network Lane Rx Loss Of Lock :This OID indicates a Rx Loss of Lock on the Client Trscv Network Lane <Help> Alarm indicating a Rx Loss of Lock on the Cli…
1.3.6.1.4.1.20044.76.2.2.2.72.1.6Columnpmo10010AlmClientLaneRxLosPortnread-onlycurrentClient Network Lane Rx Loss Of Signal :This OID indicates a Rx Loss of Signal on the Client Trscv Network Lane <Help> Alarm indicating a Rx Loss of Signal on t…
1.3.6.1.4.1.20044.76.2.2.2.72.1.8Columnpmo10010AlmClientLaneTxLolPortnread-onlycurrentClient Network Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Client Trscv Network Lane <Help> Alarm indicating a Tx Loss of Lock on the Cli…
1.3.6.1.4.1.20044.76.2.2.2.72.1.9Columnpmo10010AlmClientLaneTxLosfPortnread-onlycurrentClient Network Lane Tx Loss Of Signal Functionality :This OID indicates a Tx Loss of Signal Functionality on the Client Trscv Network Lane <Help> Alarm indicat…
1.3.6.1.4.1.20044.76.2.2.2.72.1.15Columnpmo10010AlmClientLaneApdPowerSupplyPortnread-onlycurrentClient Network Lane APD Power Supply :This OID indicates an APD Power supply failure on the Client Trscv Network Lane <Help> Alarm indicating an APD Power supp…
1.3.6.1.4.1.20044.76.2.2.2.72.1.16Columnpmo10010AlmClientLaneWavelengthUnlockedPortnread-onlycurrentClient Network Lane Wavelength Unlock :This OID indicates a Wavelength unlock on the Client Trscv Network Lane <Help> Alarm indicating a Wavelength unlock on t…
1.3.6.1.4.1.20044.76.2.2.2.72.1.17Columnpmo10010AlmClientLaneTecFaultPortnread-onlycurrentClient Network Lane TEC Fault :This OID indicates a TEC Fault on the Client Trscv Network Lane <Help> Alarm indicating a TEC Fault on the Client Trscv Network …
1.3.6.1.4.1.20044.76.2.2.2.88Tablepmo10010AlmclientHostLaneFaultTablenot-accessiblecurrentList of pmo10010AlmclientHostLaneFault Article
1.3.6.1.4.1.20044.76.2.2.2.88.1Rowpmo10010AlmclientHostLaneFaultEntrynot-accessiblecurrentRow definition for the pmo10010AlmclientHostLaneFault table
1.3.6.1.4.1.20044.76.2.2.2.88.1.1Columnpmo10010AlmclientHostLaneFaultIndexread-onlycurrentIndex definition for the pmo10010AlmclientHostLaneFault table
1.3.6.1.4.1.20044.76.2.2.2.88.1.2Columnpmo10010AlmClientRxLossOfSyncPortnread-onlycurrentClient Rx Frame Alignment Loss :This OID indicates the module is not aligned with the Rx incoming Client signal <Help> Alarm indicating the module is not align…
1.3.6.1.4.1.20044.76.2.2.2.88.1.3Columnpmo10010AlmClientInputLossOfSigPortnread-onlycurrentClient Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Client Trscv <Help> Alarm indicating a Loss of Signal is detected on the Cl…
1.3.6.1.4.1.20044.76.2.2.2.88.1.4Columnpmo10010AlmClientLanesMarkerUnlockPortnread-onlycurrentClient Lanes Marker Unlock :This OID indicates the Client lanes marker alignment is not lock <Help> Alarm indicating the Client lanes marker alignment is not l…
1.3.6.1.4.1.20044.76.2.2.2.88.1.5Columnpmo10010AlmClientLanes6466UnlockPortnread-onlycurrentClient Lanes 64/66b Unlock :This OID indicates the Client 64/66b decoder is not lock <Help> Alarm indicating the Client 64/66b decoder is not lock <Condtype> C…
1.3.6.1.4.1.20044.76.2.2.2.88.1.6Columnpmo10010AlmClientLanesNotAlignedPortnread-onlycurrentClient Lanes Not Aligned :This OID indicates the Client lanes are not aligned <Help> Alarm indicating the Client lanes are not aligned <Condtype> CLIENT_LANES_…
1.3.6.1.4.1.20044.76.2.2.2.88.1.7Columnpmo10010AlmClientCsfDetectedPortnread-onlycurrentClient Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client…
1.3.6.1.4.1.20044.76.2.2.2.88.1.10Columnpmo10010AlmClientTxHostLolPortnread-onlycurrentClient Host Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Client Trscv Host Lane <Help> Alarm indicating a Tx Loss of Lock on the Client Tr…
1.3.6.1.4.1.20044.76.2.2.2.88.1.11Columnpmo10010AlmClientLaneTxFifoErrorPortnread-onlycurrentClient Host Lane Tx FIFO Error :This OID indicates a Tx FIFO Error on the Client Trscv Host Lane <Help> Alarm indicating a Tx FIFO Error on the Client Trscv Ho…
1.3.6.1.4.1.20044.76.2.2.2.88.1.12Columnpmo10010AlmRxLocalFaultDetectedPortnread-onlycurrentRx Local Fault Signal Detected :This OID indicates a Local Fault Signal is detected on the client input port<Help> This alarm indicates a Local Fault Signal is…
1.3.6.1.4.1.20044.76.2.2.2.88.1.13Columnpmo10010AlmRxRemoteFaultDetectedPortnread-onlycurrentRx Remote Fault Signal Detected :This OID indicates a Remote Fault Signal is detected on the client input port<Help> This alarm indicates a Remote Fault Signal…
1.3.6.1.4.1.20044.76.2.2.2.88.1.14Columnpmo10010AlmTxLocalFaultDetectedPortnread-onlycurrentTx Local Fault Signal Detected :This OID indicates a Local Fault Signal is coming on the client port from the line side<Help> This alarm indicates a Local Faul…
1.3.6.1.4.1.20044.76.2.2.2.88.1.15Columnpmo10010AlmTxRemoteFaultDetectedPortnread-onlycurrentTx Remote Fault Signal Detected :This OID indicates a Remote Fault Signal is coming on the client port from the line side<Help> This alarm indicates a Remote F…
1.3.6.1.4.1.20044.76.2.2.2.88.1.16Columnpmo10010AlmClientTxLossOfSyncPortnread-onlycurrentClient Tx Frame Alignment Loss :This OID indicates the module is not aligned with the Tx incoming Client signal<Help> Alarm indicating the module is not aligne…
1.3.6.1.4.1.20044.76.2.2.2.200Tablepmo10010AlmclientOtnAlmTablenot-accessiblecurrentList of pmo10010AlmclientOtnAlm Article
1.3.6.1.4.1.20044.76.2.2.2.200.1Rowpmo10010AlmclientOtnAlmEntrynot-accessiblecurrentRow definition for the pmo10010AlmclientOtnAlm table
1.3.6.1.4.1.20044.76.2.2.2.200.1.1Columnpmo10010AlmclientOtnAlmIndexread-onlycurrentIndex definition for the pmo10010AlmclientOtnAlm table
1.3.6.1.4.1.20044.76.2.2.2.200.1.2Columnpmo10010AlmClientOtu2eDlomPortnread-onlycurrentOTU2e_DLOM :This OID indicates that a Loss Of Multiframe has been detected on client port<Help> This alarm indicates if a Loss Of Multiframe has been detected …
1.3.6.1.4.1.20044.76.2.2.2.200.1.3Columnpmo10010AlmClientOtu2eDlofPortnread-onlycurrentOTU2e_DLOF :This OID indicates the module is not aligned with the incoming Line signal<Help> Alarm indicating the module is not aligned with the incoming clien…
1.3.6.1.4.1.20044.76.2.2.2.200.1.4Columnpmo10010AlmClientOdu2eDplmPortnread-onlycurrentODU2e DPLM :This OID indicates a Payload Mismatch is detected on the Client port<Help> Alarm indicating a Payload Mismatch <Condtype> CLIENT_ODU2E_DPLM <Probca…
1.3.6.1.4.1.20044.76.2.2.2.200.1.6Columnpmo10010AlmClientOdu2eDdegPortnread-onlycurrentODU2e DDEG :This OID indicates that a Signal Degrade has been detected on client port<Help> Alarm indicating a Signal Degrade upon threshold and confirmation p…
1.3.6.1.4.1.20044.76.2.2.2.200.1.7Columnpmo10010AlmClientCsfDetectedOtnPortnread-onlycurrentETH DCSF :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client Signal Fail has be…
1.3.6.1.4.1.20044.76.2.2.2.200.1.8Columnpmo10010AlmClientOdu2eIaisPortnread-onlycurrentODU2e IAIS :This OID indicates that an Alarm Indication Signal has been inserted on client port <Help> This alarm indicates if an Alarm Indication Signal has b…
1.3.6.1.4.1.20044.76.2.2.2.200.1.9Columnpmo10010AlmClientOdu2eDtimPortnread-onlycurrentODU2e DTIM :This OID indicates that a Trace Identifier Mismatch has been detected on client port<Help> This alarm indicates if an Trace Identifier Mismatch has…
1.3.6.1.4.1.20044.76.2.2.2.200.1.10Columnpmo10010AlmClientOdu2eDaisPortnread-onlycurrentODU2e DAIS :This OID indicates that a Alarm Indication SIgnal has been detected on client port<Help> This alarm indicates if an Alarm Indication Signal has bee…
1.3.6.1.4.1.20044.76.2.2.2.200.1.12Columnpmo10010AlmClientOdu2eIociPortnread-onlycurrentODU2e IOCI :This OID indicates that an Open Connection has been inserted on client port <Help> This alarm indicates if an Open Connection Indication has been i…
1.3.6.1.4.1.20044.76.2.2.2.200.1.13Columnpmo10010AlmClientOdu2eDociPortnread-onlycurrentODU2e DOCI :This OID indicates that a Open Connection has been detected on client port <Help> This alarm indicates if an Open Connection Indication has been de…
1.3.6.1.4.1.20044.76.2.2.2.200.1.14Columnpmo10010AlmClientOdu2eIbdiPortnread-onlycurrentODU2e IBDI :This OID indicates that a Backward Defect Indication has been inserted on client port <Help> This alarm indicates if a Backward Defect Indication h…
1.3.6.1.4.1.20044.76.2.2.2.200.1.15Columnpmo10010AlmClientOdu2eDbdiPortnread-onlycurrentODU2e DBDI :This OID indicates that a Backward Defect Indication has been detected on client port<Help> This alarm indicates if a Backward Defect Indication ha…
1.3.6.1.4.1.20044.76.2.2.2.200.1.16Columnpmo10010AlmClientOdu2eIlckPortnread-onlycurrentODU2e ILCK :This OID indicates that a Locked Indication has been inserted on client port <Help> This alarm indicates if a Locked Indication has been inserted o…
1.3.6.1.4.1.20044.76.2.2.2.200.1.17Columnpmo10010AlmClientOdu2eDlckPortnread-onlycurrentODU2e DLCK :This OID indicates that a Locked Indication has been detected on client port <Help> This alarm indicates if a Locked Indication has been detected o…
1.3.6.1.4.1.20044.76.2.2.2.216Tablepmo10010AlmclientSfpAlmDdmTablenot-accessiblecurrentList of pmo10010AlmclientSfpAlmDdm Article
1.3.6.1.4.1.20044.76.2.2.2.216.1Rowpmo10010AlmclientSfpAlmDdmEntrynot-accessiblecurrentRow definition for the pmo10010AlmclientSfpAlmDdm table
1.3.6.1.4.1.20044.76.2.2.2.216.1.1Columnpmo10010AlmclientSfpAlmDdmIndexread-onlycurrentIndex definition for the pmo10010AlmclientSfpAlmDdm table
1.3.6.1.4.1.20044.76.2.2.2.216.1.2Columnpmo10010AlmTxPwrLowAlaPortnread-onlycurrentClient Trscv Tx Power Low :This OID indicates that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in…
1.3.6.1.4.1.20044.76.2.2.2.216.1.3Columnpmo10010AlmTxPwrHighAlaPortnread-onlycurrentClient Trscv Tx Power High :This OID indicates that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.76.2.2.2.216.1.4Columnpmo10010AlmTxBiasLowAlaPortnread-onlycurrentClient Trscv Bias Low :This OID indicates that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.76.2.2.2.216.1.5Columnpmo10010AlmTxBiasHighAlaPortnread-onlycurrentClient Trscv Bias High :This OID indicates that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM <Help> Alar…
1.3.6.1.4.1.20044.76.2.2.2.216.1.6Columnpmo10010AlmVccLowAlaPortnread-onlycurrentClient Trscv Power Supply Low :This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM <Help> Alar…
1.3.6.1.4.1.20044.76.2.2.2.216.1.7Columnpmo10010AlmVccHighAlaPortnread-onlycurrentClient Trscv Power Supply High :This OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM <Help> Al…
1.3.6.1.4.1.20044.76.2.2.2.216.1.8Columnpmo10010AlmTempLowAlaPortnread-onlycurrentClient Trscv Temp Low :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicat…
1.3.6.1.4.1.20044.76.2.2.2.216.1.9Columnpmo10010AlmTempHighAlaPortnread-onlycurrentClient Trscv Temp High :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indic…
1.3.6.1.4.1.20044.76.2.2.2.216.1.16Columnpmo10010AlmRxPwrLowAlaPortnread-onlycurrentClient Trscv Rx Power Low :This OID indicates that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm ind…
1.3.6.1.4.1.20044.76.2.2.2.216.1.17Columnpmo10010AlmRxPwrHighAlaPortnread-onlycurrentClient Trscv Rx Power High :This OID indicates that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm i…
1.3.6.1.4.1.20044.76.2.2.3Nodepmo10010AlmClientCrit
1.3.6.1.4.1.20044.76.2.2.3.8Tablepmo10010AlmsynthAlmPortTablenot-accessiblecurrentList of pmo10010AlmsynthAlmPort Article
1.3.6.1.4.1.20044.76.2.2.3.8.1Rowpmo10010AlmsynthAlmPortEntrynot-accessiblecurrentRow definition for the pmo10010AlmsynthAlmPort table
1.3.6.1.4.1.20044.76.2.2.3.8.1.1Columnpmo10010AlmsynthAlmPortIndexread-onlycurrentIndex definition for the pmo10010AlmsynthAlmPort table
1.3.6.1.4.1.20044.76.2.2.3.8.1.2Columnpmo10010AlmSfpAbsentPortnread-onlycurrentClient Optical Module Absent :This OID indicates that the Transceiver is not present in the client port. <Help> This alarm indicates if the client transceiver …
1.3.6.1.4.1.20044.76.2.2.3.8.1.3Columnpmo10010AlmDdmAbsentPortnread-onlycurrentDDM Supported On Client Trscv :This OID indicates that the Client transceiver supports the Digital Diagnostic Monitoring function <Help> This status indicates …
1.3.6.1.4.1.20044.76.2.2.3.8.1.5Columnpmo10010AlmHwFailAccPortnread-onlycurrentClient HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Help> This alarm indicates a failure on client port, most pro…
1.3.6.1.4.1.20044.76.2.2.3.8.1.6Columnpmo10010AlmDwLsdPortnread-onlycurrentClient Trscv Laser Shutdown :This OID indicates the Client transceiver laser is shutdown <Help> This status indicates if the client transceiver laser is shutdo…
1.3.6.1.4.1.20044.76.2.2.3.8.1.7Columnpmo10010AlmClientLocalOosPortnread-onlycurrentLocal Client Port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local c…
1.3.6.1.4.1.20044.76.2.2.3.8.1.8Columnpmo10010AlmClientRemoteOosPortnread-onlycurrentRemote Client Port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the remot…
1.3.6.1.4.1.20044.76.2.2.3.8.1.9Columnpmo10010AlmDwCaisPortnread-onlycurrentClient AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indicates if a Client Alarm Indication Signal is…
1.3.6.1.4.1.20044.76.2.2.3.8.1.10Columnpmo10010AlmSfpDdmWarningPortnread-onlycurrentWarning On Client Trscv DDM :This OID indicates a warning is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Warning has be…
1.3.6.1.4.1.20044.76.2.2.3.8.1.11Columnpmo10010AlmSfpDdmAlmPortnread-onlycurrentAlarm On Client Trscv DDM :This OID indicates an alarm is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Alarm has been de…
1.3.6.1.4.1.20044.76.2.2.3.8.1.13Columnpmo10010AlmFailAccPortnread-onlycurrentClient Access Fail :This OID indicates a failure on the Client port <Help> This alarm indicates a failure on the Client port <Condtype> FAIL_ACC_1 <Probcause> …
1.3.6.1.4.1.20044.76.2.2.3.8.1.17Columnpmo10010AlmUpCsfPortnread-onlycurrentClient Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu…
1.3.6.1.4.1.20044.76.2.3Nodepmo10010AlmLine
1.3.6.1.4.1.20044.76.2.3.1Nodepmo10010AlmLineNurg
1.3.6.1.4.1.20044.76.2.3.1.104Tablepmo10010AlmlineNetworkLaneAlarmWarning1Tablenot-accessiblecurrentList of pmo10010AlmlineNetworkLaneAlarmWarning1 Article
1.3.6.1.4.1.20044.76.2.3.1.104.1Rowpmo10010AlmlineNetworkLaneAlarmWarning1Entrynot-accessiblecurrentRow definition for the pmo10010AlmlineNetworkLaneAlarmWarning1 table
1.3.6.1.4.1.20044.76.2.3.1.104.1.1Columnpmo10010AlmlineNetworkLaneAlarmWarning1Indexread-onlycurrentIndex definition for the pmo10010AlmlineNetworkLaneAlarmWarning1 table
1.3.6.1.4.1.20044.76.2.3.1.104.1.2Columnpmo10010AlmLineRxPowerLowAlarmPortnread-onlycurrentLine Trscv Rx Power Low Alarm :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicat…
1.3.6.1.4.1.20044.76.2.3.1.104.1.3Columnpmo10010AlmLineRxPowerLowWarningPortnread-onlycurrentLine Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning ind…
1.3.6.1.4.1.20044.76.2.3.1.104.1.4Columnpmo10010AlmLineRxPowerHighWarningPortnread-onlycurrentLine Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning i…
1.3.6.1.4.1.20044.76.2.3.1.104.1.5Columnpmo10010AlmLineRxPowerHighAlarmPortnread-onlycurrentLine Trscv Rx Power High Alarm :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indic…
1.3.6.1.4.1.20044.76.2.3.1.104.1.6Columnpmo10010AlmLineLaserTempLowAlarmPortnread-onlycurrentLine Trscv Tx Laser Temp Low Alarm :This OID indicates that the Trscv Tx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help>…
1.3.6.1.4.1.20044.76.2.3.1.104.1.7Columnpmo10010AlmLineLaserTempLowWarningPortnread-onlycurrentLine Trscv Tx Laser Temp Low Warning :This OID indicates that the Trscv Tx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Hel…
1.3.6.1.4.1.20044.76.2.3.1.104.1.8Columnpmo10010AlmLineLaserTempHighWarningPortnread-onlycurrentLine Trscv Tx Laser Temp High Warning :This OID indicates that the Trscv Tx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <H…
1.3.6.1.4.1.20044.76.2.3.1.104.1.9Columnpmo10010AlmLineLaserTempHighAlarmPortnread-onlycurrentLine Trscv Tx Laser Temp High Alarm :This OID indicates that the Trscv Tx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Hel…
1.3.6.1.4.1.20044.76.2.3.1.104.1.10Columnpmo10010AlmLineTxPowerLowAlarmPortnread-onlycurrentLine Trscv Tx Power Low Alarm :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indica…
1.3.6.1.4.1.20044.76.2.3.1.104.1.11Columnpmo10010AlmLineTxPowerLowWarningPortnread-onlycurrentLine Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning in…
1.3.6.1.4.1.20044.76.2.3.1.104.1.12Columnpmo10010AlmLineTxPowerHighWarningPortnread-onlycurrentLine Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.76.2.3.1.104.1.13Columnpmo10010AlmLineTxPowerHighAlarmPortnread-onlycurrentLine Trscv Tx Power High Alarm :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indi…
1.3.6.1.4.1.20044.76.2.3.1.104.1.14Columnpmo10010AlmLineBiasLowAlarmPortnread-onlycurrentLine Trscv Tx Bias Low Alarm :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alarm i…
1.3.6.1.4.1.20044.76.2.3.1.104.1.15Columnpmo10010AlmLineBiasLowWarningPortnread-onlycurrentLine Trscv Tx Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warni…
1.3.6.1.4.1.20044.76.2.3.1.104.1.16Columnpmo10010AlmLineBiasHighWarningPortnread-onlycurrentLine Trscv Tx Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> War…
1.3.6.1.4.1.20044.76.2.3.1.104.1.17Columnpmo10010AlmLineBiasHighAlarmPortnread-onlycurrentLine Trscv Tx Bias High Alarm :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Alarm…
1.3.6.1.4.1.20044.76.2.3.1.120Tablepmo10010AlmlineNetworkLaneAlarmWarning2Tablenot-accessiblecurrentList of pmo10010AlmlineNetworkLaneAlarmWarning2 Article
1.3.6.1.4.1.20044.76.2.3.1.120.1Rowpmo10010AlmlineNetworkLaneAlarmWarning2Entrynot-accessiblecurrentRow definition for the pmo10010AlmlineNetworkLaneAlarmWarning2 table
1.3.6.1.4.1.20044.76.2.3.1.120.1.1Columnpmo10010AlmlineNetworkLaneAlarmWarning2Indexread-onlycurrentIndex definition for the pmo10010AlmlineNetworkLaneAlarmWarning2 table
1.3.6.1.4.1.20044.76.2.3.1.120.1.2Columnpmo10010AlmTxModulatorBiasLowAlarmPortnread-onlycurrentLine Trscv Tx Modulator Bias Low Alarm :This OID indicates that the Trscv Tx modulator bias current is lower than the threshold value written in the Trscv EEPR…
1.3.6.1.4.1.20044.76.2.3.1.120.1.3Columnpmo10010AlmTxModulatorBiasLowWarningPortnread-onlycurrentLine Trscv Tx Modulator Bias Low Warning :This OID indicates that the Trscv Tx modulator bias current is lower than the threshold value written in the Trscv EE…
1.3.6.1.4.1.20044.76.2.3.1.120.1.4Columnpmo10010AlmTxModulatorBiasHighWarningPortnread-onlycurrentLine Trscv Tx Modulator Bias High Warning :This OID indicates that the Trscv Tx modulator bias current is higher than the threshold value written in the Trscv …
1.3.6.1.4.1.20044.76.2.3.1.120.1.5Columnpmo10010AlmTxModulatorBiasHighAlarmPortnread-onlycurrentLine Trscv Tx Modulator Bias High Alarm :This OID indicates that the Trscv Tx modulator bias current is higher than the threshold value written in the Trscv EE…
1.3.6.1.4.1.20044.76.2.3.1.120.1.6Columnpmo10010AlmRxLaserTempLowAlarmPortnread-onlycurrentLine Trscv Rx Laser Temp Low Alarm :This OID indicates that the Trscv Rx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help>…
1.3.6.1.4.1.20044.76.2.3.1.120.1.7Columnpmo10010AlmRxLaserTempLowWarningPortnread-onlycurrentLine Trscv Rx Laser Temp Low Warning :This OID indicates that the Trscv Rx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Hel…
1.3.6.1.4.1.20044.76.2.3.1.120.1.8Columnpmo10010AlmRxLaserTempHighWarningPortnread-onlycurrentLine Trscv Rx Laser Temp High Warning :This OID indicates that the Trscv Rx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <H…
1.3.6.1.4.1.20044.76.2.3.1.120.1.9Columnpmo10010AlmRxLaserTempHighAlarmPortnread-onlycurrentLine Trscv Rx Laser Temp High Alarm :This OID indicates that the Trscv Rx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Hel…
1.3.6.1.4.1.20044.76.2.3.1.120.1.10Columnpmo10010AlmRxLaserOutputLowAlarmPortnread-onlycurrentLine Trscv Rx Output Power Low Alarm :This OID indicates that the Trscv Rx output power is lower than the threshold value written in the Trscv EEPROM <Help> Al…
1.3.6.1.4.1.20044.76.2.3.1.120.1.11Columnpmo10010AlmRxLaserOutputLowWarningPortnread-onlycurrentLine Trscv Rx Output Power Low Warning :This OID indicates that the Trscv Rx output power is lower than the threshold value written in the Trscv EEPROM <Help> …
1.3.6.1.4.1.20044.76.2.3.1.120.1.12Columnpmo10010AlmRxLaserOutputHighWarningPortnread-onlycurrentLine Trscv Rx Output Power High Warning :This OID indicates that the Trscv Rx output power is higher than the threshold value written in the Trscv EEPROM <Help…
1.3.6.1.4.1.20044.76.2.3.1.120.1.13Columnpmo10010AlmRxLaserOutputHighAlarmPortnread-onlycurrentLine Trscv Rx Output Power High Alarm :This OID indicates that the Trscv Rx output power is higher than the threshold value written in the Trscv EEPROM <Help> …
1.3.6.1.4.1.20044.76.2.3.1.120.1.14Columnpmo10010AlmRxLaserBiasLowAlarmPortnread-onlycurrentLine Trscv Rx Bias Low Alarm :This OID indicates that the Trscv Rx laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alar…
1.3.6.1.4.1.20044.76.2.3.1.120.1.15Columnpmo10010AlmRxLaserBiasLowWarningPortnread-onlycurrentLine Trscv Rx Bias Low Warning :This OID indicates that the Trscv Rx laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Wa…
1.3.6.1.4.1.20044.76.2.3.1.120.1.16Columnpmo10010AlmRxLaserBiasHighWarningPortnread-onlycurrentLine Trscv Rx Bias High Warning :This OID indicates that the Trscv Rx laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> …
1.3.6.1.4.1.20044.76.2.3.1.120.1.17Columnpmo10010AlmRxLaserBiasHighAlarmPortnread-onlycurrentLine Trscv Rx Bias High Alarm :This OID indicates that the Trscv Rx laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Al…
1.3.6.1.4.1.20044.76.2.3.2Nodepmo10010AlmLineUrg
1.3.6.1.4.1.20044.76.2.3.2.136Tablepmo10010AlmlineNetworkLaneFaultTablenot-accessiblecurrentList of pmo10010AlmlineNetworkLaneFault Article
1.3.6.1.4.1.20044.76.2.3.2.136.1Rowpmo10010AlmlineNetworkLaneFaultEntrynot-accessiblecurrentRow definition for the pmo10010AlmlineNetworkLaneFault table
1.3.6.1.4.1.20044.76.2.3.2.136.1.1Columnpmo10010AlmlineNetworkLaneFaultIndexread-onlycurrentIndex definition for the pmo10010AlmlineNetworkLaneFault table
1.3.6.1.4.1.20044.76.2.3.2.136.1.3Columnpmo10010AlmLineLaneRxTecFaultPortnread-onlycurrentLine Network Lane Rx TEC Fault :This OID indicates a Rx TEC Fault on the Line Trscv Network Lane <Help> Alarm indicating a Rx TEC Fault on the Line Trscv Netwo…
1.3.6.1.4.1.20044.76.2.3.2.136.1.4Columnpmo10010AlmLineLaneRxFifoErrorPortnread-onlycurrentLine Network Lane Rx FIFO Error :This OID indicates a Rx FIFO Error on the Line Trscv Network Lane <Help> Alarm indicating a Rx FIFO Error on the Line Trscv Ne…
1.3.6.1.4.1.20044.76.2.3.2.136.1.5Columnpmo10010AlmLineLaneRxLolPortnread-onlycurrentLine Network Lane Rx Loss Of Lock :This OID indicates a Rx Loss of Lock on the Line Trscv Network Lane <Help> Alarm indicating a Rx Loss of Lock on the Line Tr…
1.3.6.1.4.1.20044.76.2.3.2.136.1.6Columnpmo10010AlmLineLaneRxLosPortnread-onlycurrentLine Network Lane Rx Loss Of Signal :This OID indicates a Rx Loss of Signal on the Line Trscv Network Lane <Help> Alarm indicating a Rx Loss of Signal on the L…
1.3.6.1.4.1.20044.76.2.3.2.136.1.8Columnpmo10010AlmLineLaneTxLolPortnread-onlycurrentLine Network Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Line Trscv Network Lane <Help> Alarm indicating a Tx Loss of Lock on the Line Tr…
1.3.6.1.4.1.20044.76.2.3.2.136.1.9Columnpmo10010AlmLineLaneTxLosfPortnread-onlycurrentLine Network Lane Tx Loss Of Signal Functionality :This OID indicates a Tx Loss of Signal Functionality on the Line Trscv Network Lane <Help> Alarm indicating …
1.3.6.1.4.1.20044.76.2.3.2.136.1.15Columnpmo10010AlmLineLaneApdPowerSupplyPortnread-onlycurrentLine Network Lane APD Power Supply :This OID indicates an APD Power supply failure on the Line Trscv Network Lane <Help> Alarm indicating an APD Power supply f…
1.3.6.1.4.1.20044.76.2.3.2.136.1.16Columnpmo10010AlmLineLaneWavelengthUnlockedPortnread-onlycurrentLine Network Lane Wavelength Unlock :This OID indicates a Wavelength unlock on the Line Trscv Network Lane <Help> Alarm indicating a Wavelength unlock on the L…
1.3.6.1.4.1.20044.76.2.3.2.136.1.17Columnpmo10010AlmLineLaneTecFaultPortnread-onlycurrentLine Network Lane TEC Fault :This OID indicates a Tx TEC Fault on the Line Trscv Network Lane <Help> Alarm indicating a Tx TEC Fault on the Line Trscv Network …
1.3.6.1.4.1.20044.76.2.3.2.152Tablepmo10010AlmlineOtu4AlarmTablenot-accessiblecurrentList of pmo10010AlmlineOtu4Alarm Article
1.3.6.1.4.1.20044.76.2.3.2.152.1Rowpmo10010AlmlineOtu4AlarmEntrynot-accessiblecurrentRow definition for the pmo10010AlmlineOtu4Alarm table
1.3.6.1.4.1.20044.76.2.3.2.152.1.1Columnpmo10010AlmlineOtu4AlarmIndexread-onlycurrentIndex definition for the pmo10010AlmlineOtu4Alarm table
1.3.6.1.4.1.20044.76.2.3.2.152.1.2Columnpmo10010AlmLineInputLossOfSignalPortnread-onlycurrentOPS4 DLOS-P :This OID indicates a Loss of Signal is detected on the Line Trscv <Help> Alarm indicating a Loss of Signal is detected on the Line Trscv <Condtype…
1.3.6.1.4.1.20044.76.2.3.2.152.1.3Columnpmo10010AlmLineLossOfFramePortnread-onlycurrentOTU4 - DLOF :This OID indicates the module is not aligned with the incoming Line signal <Help> Alarm indicating the module is not aligned with the incoming Lin…
1.3.6.1.4.1.20044.76.2.3.2.152.1.4Columnpmo10010AlmLineSmBdiInsertedPortnread-onlycurrentOTU4 IBDI :This OID indicates a SM Backward Defect Indication is inserted on the outgoing Line signal <Help> Status indicating a SM Backward Defect Indication …
1.3.6.1.4.1.20044.76.2.3.2.152.1.5Columnpmo10010AlmLineSmBdiDetectedPortnread-onlycurrentOTU4 DBDI :This OID indicates a SM Backward Defect Indication is detected on the incoming Line signal <Help> Alarm indicating a SM Backward Defect Indication i…
1.3.6.1.4.1.20044.76.2.3.2.152.1.6Columnpmo10010AlmLineSmIaeInsertedPortnread-onlycurrentLine SM IAE Inserted :This OID indicates a SM Incoming Alignment Error is inserted on the outgoing Line signal <Help> Status indicating a SM Incoming Alignment…
1.3.6.1.4.1.20044.76.2.3.2.152.1.7Columnpmo10010AlmLineSmIaeDetectedPortnread-onlycurrentLine SM IAE Detected :This OID indicates a SM Incoming Alignment Error is detected on the incoming Line signal <Help> Alarm indicating a SM Incoming Alignment …
1.3.6.1.4.1.20044.76.2.3.2.152.1.8Columnpmo10010AlmOtu4DdegPortnread-onlycurrentOTU4 DDEG :This OID indicates that a Signal Degrade has been detected on line port <Help> This alarm indicates if a Signal Degrade has been detected upon thres…
1.3.6.1.4.1.20044.76.2.3.2.152.1.9Columnpmo10010AlmClientOtu4DtimPortnread-onlycurrentOTU4 DTIM :This OID indicates that a Trace Identifier Mismatch has been detected on line port <Help> This alarm indicates if a Trace Identifier Mismatch has be…
1.3.6.1.4.1.20044.76.2.3.2.152.1.10Columnpmo10010AlmLineTxHostLolPortnread-onlycurrentLine Host Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Line Trscv Host Lane <Help> Alarm indicating a Tx Loss of Lock on the Line Trscv Ho…
1.3.6.1.4.1.20044.76.2.3.2.152.1.11Columnpmo10010AlmLineLaneTxFifoErrorPortnread-onlycurrentLine Host Lane Tx FIFO Error :This OID indicates a Tx FIFO Error on the Line Trscv Host Lane <Help> Alarm indicating a Tx FIFO Error on the Line Trscv Host Lan…
1.3.6.1.4.1.20044.76.2.3.2.152.1.12Columnpmo10010AlmLineOchr4DlosPPortnread-onlycurrentOchr4 - DLOS-P :This OID indicates that a Transmitter failure has been detected on line port <Help> This alarm indicates if a Transmitter Failure has been dete…
1.3.6.1.4.1.20044.76.2.3.2.152.1.16Columnpmo10010AlmLineOtu4DssfPortnread-onlycurrentOTU4 DSSF :This OID indicates that a Server Signal failure has been detected on line port <Help> This alarm indicates if a Server Signal Failure has been detec…
1.3.6.1.4.1.20044.76.2.3.2.152.1.17Columnpmo10010AlmLineOtu4DlomPortnread-onlycurrentOTU4 DLOM :This OID indicates that a Loss Of Multiframe has been detected on line port <Help> This alarm indicates if a Loss Of Multiframe has been detected on…
1.3.6.1.4.1.20044.76.2.3.2.168Tablepmo10010AlmlineNetworkLaneRxOtnTablenot-accessiblecurrentList of pmo10010AlmlineNetworkLaneRxOtn Article
1.3.6.1.4.1.20044.76.2.3.2.168.1Rowpmo10010AlmlineNetworkLaneRxOtnEntrynot-accessiblecurrentRow definition for the pmo10010AlmlineNetworkLaneRxOtn table
1.3.6.1.4.1.20044.76.2.3.2.168.1.1Columnpmo10010AlmlineNetworkLaneRxOtnIndexread-onlycurrentIndex definition for the pmo10010AlmlineNetworkLaneRxOtn table
1.3.6.1.4.1.20044.76.2.3.2.168.1.10Columnpmo10010AlmLineRxOtnOduAisPortnread-onlycurrentLine Network Rx ODU AIS :This OID indicates an ODU This OID Indication Signal is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating…
1.3.6.1.4.1.20044.76.2.3.2.168.1.11Columnpmo10010AlmLineRxOtnOtuAisPortnread-onlycurrentLine Network Rx OTU AIS :This OID indicates an OTU This OID Indication Signal is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating…
1.3.6.1.4.1.20044.76.2.3.2.168.1.12Columnpmo10010AlmLineRxSmBdiPortnread-onlycurrentLine Network Rx SM BDI :This OID indicates an SM Backward Defect Indication is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating a…
1.3.6.1.4.1.20044.76.2.3.2.168.1.13Columnpmo10010AlmLineRxOtnIaePortnread-onlycurrentLine Network Rx IAE :This OID indicates an Incoming Alignment Error is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating an Incomi…
1.3.6.1.4.1.20044.76.2.3.2.168.1.14Columnpmo10010AlmLineRxOtnOomPortnread-onlycurrentLine Network Rx OOM :This OID indicates an Out of Multiframe is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating an Out of Multif…
1.3.6.1.4.1.20044.76.2.3.2.168.1.15Columnpmo10010AlmLineRxOtnLomPortnread-onlycurrentLine Network Rx LOM :This OID indicates a Loss of Multiframe is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating a Loss of Multif…
1.3.6.1.4.1.20044.76.2.3.2.168.1.16Columnpmo10010AlmLineRxOtnOofPortnread-onlycurrentLine Network Rx OOF :This OID indicates an Out of Frame is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating an Out of Frame is de…
1.3.6.1.4.1.20044.76.2.3.2.168.1.17Columnpmo10010AlmLineRxOtnLofPortnread-onlycurrentLine Network Rx LOF :This OID indicates a Loss of Frame is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating a Loss of Frame is de…
1.3.6.1.4.1.20044.76.2.3.2.184Tablepmo10010AlmlineHostLaneTxOtnTablenot-accessiblecurrentList of pmo10010AlmlineHostLaneTxOtn Article
1.3.6.1.4.1.20044.76.2.3.2.184.1Rowpmo10010AlmlineHostLaneTxOtnEntrynot-accessiblecurrentRow definition for the pmo10010AlmlineHostLaneTxOtn table
1.3.6.1.4.1.20044.76.2.3.2.184.1.1Columnpmo10010AlmlineHostLaneTxOtnIndexread-onlycurrentIndex definition for the pmo10010AlmlineHostLaneTxOtn table
1.3.6.1.4.1.20044.76.2.3.2.184.1.10Columnpmo10010AlmLineTxOtnOduAisPortnread-onlycurrentLine Host Tx ODU AIS :This OID indicates an ODU This OID Indication Signal is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an OD…
1.3.6.1.4.1.20044.76.2.3.2.184.1.11Columnpmo10010AlmLineTxOtnOtuAisPortnread-onlycurrentLine Host Tx OTU AIS :This OID indicates an OTU This OID Indication Signal is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an OT…
1.3.6.1.4.1.20044.76.2.3.2.184.1.12Columnpmo10010AlmLineTxSmBdiPortnread-onlycurrentLine Host Tx SM BDI :This OID indicates an SM Backward Defect Indication is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an SM B…
1.3.6.1.4.1.20044.76.2.3.2.184.1.13Columnpmo10010AlmLineTxOtnIaePortnread-onlycurrentLine Host Tx IAE :This OID indicates an Incoming Alignment Error is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an Incoming Ali…
1.3.6.1.4.1.20044.76.2.3.2.184.1.14Columnpmo10010AlmLineTxOtnOomPortnread-onlycurrentLine Host Tx OOM :This OID indicates an Out of Multiframe is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an Out of Multiframe i…
1.3.6.1.4.1.20044.76.2.3.2.184.1.15Columnpmo10010AlmLineTxOtnLomPortnread-onlycurrentLine Host Tx LOM :This OID indicates a Loss of Multiframe is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating a Loss of Multiframe i…
1.3.6.1.4.1.20044.76.2.3.2.184.1.16Columnpmo10010AlmLineTxOtnOofPortnread-onlycurrentLine Host Tx OOF :This OID indicates an Out of Frame is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an Out of Frame is detected…
1.3.6.1.4.1.20044.76.2.3.2.184.1.17Columnpmo10010AlmLineTxOtnLofPortnread-onlycurrentLine Host Tx LOF :This OID indicates a Loss of Frame is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating a Loss of Frame is detected…
1.3.6.1.4.1.20044.76.2.3.2.256Tablepmo10010AlmlineOdu4AlmTablenot-accessiblecurrentList of pmo10010AlmlineOdu4Alm Article
1.3.6.1.4.1.20044.76.2.3.2.256.1Rowpmo10010AlmlineOdu4AlmEntrynot-accessiblecurrentRow definition for the pmo10010AlmlineOdu4Alm table
1.3.6.1.4.1.20044.76.2.3.2.256.1.1Columnpmo10010AlmlineOdu4AlmIndexread-onlycurrentIndex definition for the pmo10010AlmlineOdu4Alm table
1.3.6.1.4.1.20044.76.2.3.2.256.1.4Columnpmo10010AlmLineOdu4DplmPortnread-onlycurrentODU4 DPLM :This OID indicates a Payload Mismatch is detected on the line port<Help> Alarm indicating a Payload Mismatch <Condtype> LINE_ODU4_DPLM <Probcause> r…
1.3.6.1.4.1.20044.76.2.3.2.256.1.6Columnpmo10010AlmLineOdu4DdegPortnread-onlycurrentODU4 DDEG :This OID indicates that a Signal Degrade has been detected on line port<Help> Alarm indicating a Signal Degrade upon threshold and confirmation para…
1.3.6.1.4.1.20044.76.2.3.2.256.1.8Columnpmo10010AlmLineOdu4IaisPortnread-onlycurrentODU4 IAIS :This OID indicates that an Alarm Indication Signal has been inserted on line port <Help> This alarm indicates if an Alarm Indication Signal has been…
1.3.6.1.4.1.20044.76.2.3.2.256.1.9Columnpmo10010AlmLineOdu4DtimPortnread-onlycurrentODU4 DTIM :This OID indicates that a Trace Identifier Mismatch has been detected on line port<Help> This alarm indicates if an Trace Identifier Mismatch has be…
1.3.6.1.4.1.20044.76.2.3.2.256.1.10Columnpmo10010AlmLineOdu4DaisPortnread-onlycurrentODU4 DAIS :This OID indicates that a Alarm Indication SIgnal has been detected on line port<Help> This alarm indicates if an Alarm Indication Signal has been d…
1.3.6.1.4.1.20044.76.2.3.2.256.1.12Columnpmo10010AlmLineOdu4IociPortnread-onlycurrentODU4 IOCI :This OID indicates that an Open Connection has been inserted on line port <Help> This alarm indicates if an Open Connection Indication has been inse…
1.3.6.1.4.1.20044.76.2.3.2.256.1.13Columnpmo10010AlmLineOdu4DociPortnread-onlycurrentODU4 DOCI :This OID indicates that a Open Connection has been detected on line port <Help> This alarm indicates if an Open Connection Indication has been detec…
1.3.6.1.4.1.20044.76.2.3.2.256.1.14Columnpmo10010AlmLineOdu4IbdiPortnread-onlycurrentODU4 IBDI :This OID indicates that a Backward Defect Indication has been inserted on line port <Help> This alarm indicates if a Backward Defect Indication has …
1.3.6.1.4.1.20044.76.2.3.2.256.1.15Columnpmo10010AlmLineOdu4DbdiPortnread-onlycurrentODU4 DBDI :This OID indicates that a Backward Defect Indication has been detected on line port<Help> This alarm indicates if a Backward Defect Indication has b…
1.3.6.1.4.1.20044.76.2.3.2.256.1.16Columnpmo10010AlmLineOdu4IlckPortnread-onlycurrentODU4 ILCK :This OID indicates that a Locked Indication has been inserted on line port <Help> This alarm indicates if a Locked Indication has been inserted on t…
1.3.6.1.4.1.20044.76.2.3.2.256.1.17Columnpmo10010AlmLineOdu4DlckPortnread-onlycurrentODU4 DLCK :This OID indicates that a Locked Indication has been detected on line port <Help> This alarm indicates if a Locked Indication has been detected on t…
1.3.6.1.4.1.20044.76.2.3.3Nodepmo10010AlmLineCrit
1.3.6.1.4.1.20044.76.2.3.3.24Tablepmo10010AlmsynthAlmLineTablenot-accessiblecurrentList of pmo10010AlmsynthAlmLine Article
1.3.6.1.4.1.20044.76.2.3.3.24.1Rowpmo10010AlmsynthAlmLineEntrynot-accessiblecurrentRow definition for the pmo10010AlmsynthAlmLine table
1.3.6.1.4.1.20044.76.2.3.3.24.1.1Columnpmo10010AlmsynthAlmLineIndexread-onlycurrentIndex definition for the pmo10010AlmsynthAlmLine table
1.3.6.1.4.1.20044.76.2.3.3.24.1.2Columnpmo10010AlmXfpAbsentPortnread-onlycurrentLine Optical Module Absent :This OID indicates that the line optical interface is not present. <Help> This alarm indicates if the line transceiver is not plugg…
1.3.6.1.4.1.20044.76.2.3.3.24.1.3Columnpmo10010AlmXfpInitNotComplPortnread-onlycurrentLine Optical Module Ready :This OID indicates that the optical interface is not operational. <Help> This status indicates if the line transceiver has been corr…
1.3.6.1.4.1.20044.76.2.3.3.24.1.5Columnpmo10010AlmLineHwFailPortnread-onlycurrentLine Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Help> This alarm indicates a failure on line port, most pr…
1.3.6.1.4.1.20044.76.2.3.3.24.1.6Columnpmo10010AlmXfpTxOffPortnread-onlycurrentLine Trscv Laser Shutdown :This OID indicates the Line transceiver laser is shutdown <Help> This status indicates if the Line transceiver laser is shutdown <Co…
1.3.6.1.4.1.20044.76.2.3.3.24.1.7Columnpmo10010AlmLineLocalOosPortnread-onlycurrentLine Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service…
1.3.6.1.4.1.20044.76.2.3.3.24.1.9Columnpmo10010AlmUpRdiInsPortnread-onlycurrentMS-RDI/L-RDI Inserted On Line :This OID indicates an upstream MS-RDI/L-RDI has been inserted in the outgoing 10 Gb/s SDH/SONET signal. <Help> This status indic…
1.3.6.1.4.1.20044.76.2.3.3.24.1.10Columnpmo10010AlmLineDdmWarningPortnread-onlycurrentWarning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Warning has…
1.3.6.1.4.1.20044.76.2.3.3.24.1.11Columnpmo10010AlmLineDdmAlmPortnread-onlycurrentAlarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Alarm has been…
1.3.6.1.4.1.20044.76.2.3.3.24.1.13Columnpmo10010AlmLineFailPortnread-onlycurrentLine Port Failure :This OID indicates a failure on the line port <Help> This alarm indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipm…
1.3.6.1.4.1.20044.76.2.3.3.24.1.17Columnpmo10010AlmLineActivePortnread-onlycurrentLine Active :This OID indicates whether the line is active or standby. <Help> This status indicates whether the line is active or standby. <Condtype> LINE_ACTI…
1.3.6.1.4.1.20044.76.3Nodepmo10010measures
1.3.6.1.4.1.20044.76.3.1Nodepmo10010MesrOther
1.3.6.1.4.1.20044.76.3.1.0Scalarpmo10010Mesrsynth0read-onlydeprecatedNot Used :
1.3.6.1.4.1.20044.76.3.1.1Scalarpmo10010Mesrsynth1read-onlydeprecatedNot Used :
1.3.6.1.4.1.20044.76.3.1.7Scalarpmo10010MesrpmIntervalNumberread-onlycurrentPM Interval Counter :
1.3.6.1.4.1.20044.76.3.1.180Scalarpmo10010MesrlineNetTxLaserOutputPwrAverageread-onlycurrentAverage Line Trscv Tx Power :This OID gives the average Tx Laser transmit power value among the network lanes of the Line Transceiver, read in the DDM (Digital…
1.3.6.1.4.1.20044.76.3.1.181Scalarpmo10010MesrlineNetTxLaserTempAverageread-onlycurrentAverage Line Trscv Tx Laser Temperature :This OID gives the average Tx Laser Temperature value among the network lanes of the Line Transceiver, read from the D…
1.3.6.1.4.1.20044.76.3.1.182Scalarpmo10010MesrlineNetTxBiasCurrentAverageread-onlycurrentAverage Line Trscv Tx Laser Bias :This OID gives the average Tx Laser Bias value among the network lanes of the Line Transceiver, read from the DDM (Digital Di…
1.3.6.1.4.1.20044.76.3.1.183Scalarpmo10010MesrlineNetRxInputPwrAverageread-onlycurrentAverage Line Trscv Rx Power :This OID gives the average Receive power value among the network lanes of the Line Transceiver, read in the DDM (Digital Diagnosti…
1.3.6.1.4.1.20044.76.3.1.184Scalarpmo10010MesrlineResidualChromaticDispAverageread-onlycurrentAverage Residual Chromatic Dispersion :This OID gives the average Residual Chromatic Dispersion on the Line interface since the last measure reset <Help> This …
1.3.6.1.4.1.20044.76.3.1.185Scalarpmo10010MesrlineDiffGroupDelayAverageread-onlycurrentAverage Differential Group Delay :This OID gives the average Group Delay on the Line interface since the last measure reset <Help> This measure gives the avera…
1.3.6.1.4.1.20044.76.3.1.186Scalarpmo10010MesrlineQFactorAverageread-onlycurrentAverage Q Factor :This OID gives the average Q Factor on the Line interface since the last measure reset <Help> This measure gives the average Q Factor on the …
1.3.6.1.4.1.20044.76.3.1.187Scalarpmo10010MesrlineCarrierFreqOffsetAverageread-onlycurrentAverage Carrier Frequency Offset :This OID gives the average Carrier Frequency Offset on the Line interface since the last measure reset <Help> This measure gi…
1.3.6.1.4.1.20044.76.3.1.188Scalarpmo10010MesrlineOsnrAverageread-onlycurrentAverage OSNR :This OID gives the average OSNR on the Line interface since the last measure reset <Help> This measure gives the average OSNR on the Line interfa…
1.3.6.1.4.1.20044.76.3.1.192Scalarpmo10010MesrclientNetTxTempMinread-onlycurrentMin Client Trscv Laser Temperature :This OID gives the minimum Laser temperature value among the network lanes of the Client Transceiver, read from the DDM (Di…
1.3.6.1.4.1.20044.76.3.1.193Scalarpmo10010MesrclientNetTxBiasMinread-onlycurrentMin Client Trscv Laser Bias :This OID gives the minimum Laser bias value among the network lanes of the Client Transceiver, read from the DDM (Digital Diagnost…
1.3.6.1.4.1.20044.76.3.1.194Scalarpmo10010MesrclientNetTxPwrMinread-onlycurrentMin Client Trscv Tx Power :This OID gives the minimum transmit power value among the network lanes of the Client Transceiver, read from the DDM (Digital Diagno…
1.3.6.1.4.1.20044.76.3.1.195Scalarpmo10010MesrclientNetRxPwrMinread-onlycurrentMin Client Trscv Rx Power :This OID gives the minimum receive power value among the network lanes of the Client Transceiver, read in the DDM (Digital Diagnosti…
1.3.6.1.4.1.20044.76.3.1.196Scalarpmo10010MesrlineNetTxLaserOutputPwrMinread-onlycurrentMin Line Trscv Tx Power :This OID gives the minimum Tx Laser transmit power value among the network lanes of the Line Transceiver, read in the DDM (Digital Dia…
1.3.6.1.4.1.20044.76.3.1.197Scalarpmo10010MesrlineNetTxLaserTempMinread-onlycurrentMin Line Trscv Tx Laser Temperature :This OID gives the minimum Tx Laser Temperature value among the network lanes of the Line Transceiver, read from the DDM (…
1.3.6.1.4.1.20044.76.3.1.198Scalarpmo10010MesrlineNetTxBiasCurrentMinread-onlycurrentMin Line Trscv Tx Laser Bias :This OID gives the minimum Tx Laser Bias value among the network lanes of the Line Transceiver, read from the DDM (Digital Diagno…
1.3.6.1.4.1.20044.76.3.1.199Scalarpmo10010MesrlineNetRxInputPwrMinread-onlycurrentMin Line Trscv Rx Power :This OID gives the minimum Receive power value among the network lanes of the Line Transceiver, read in the DDM (Digital Diagnostic Mo…
1.3.6.1.4.1.20044.76.3.1.200Scalarpmo10010MesrlineResidualChromaticDispMinread-onlycurrentMin Residual Chromatic Dispersion :This OID gives the minimum Residual Chromatic Dispersion on the Line interface since the last measure reset (Unit = ps/nm)<H…
1.3.6.1.4.1.20044.76.3.1.201Scalarpmo10010MesrlineDiffGroupDelayMinread-onlycurrentMin Differential Group Delay :This OID gives the minimum Differential Group Delay on the Line interface since the last measure reset (Unit = ps)<Help> This mea…
1.3.6.1.4.1.20044.76.3.1.202Scalarpmo10010MesrlineQFactorMinread-onlycurrentMin Q Factor :This OID gives the minimum Q Factor on the Line interface since the last measure reset (Unit = dB)<Help> This measure gives the minimum Q Factor …
1.3.6.1.4.1.20044.76.3.1.203Scalarpmo10010MesrlineCarrierFreqOffsetMinread-onlycurrentMin Carrier Frequency Offset :This OID gives the minimum Carrier Frequency Offset on the Line interface since the last measure reset (Unit = Mhz)<Help> This me…
1.3.6.1.4.1.20044.76.3.1.204Scalarpmo10010MesrlineOsnrMinread-onlycurrentMin OSNR :This OID gives the minimum OSNR on the Line interface since the last measure reset (OSNR = AV/10) (Unit = dB)<Help> This measure gives the minimum OS…
1.3.6.1.4.1.20044.76.3.1.208Scalarpmo10010MesrclientNetTxTempMaxread-onlycurrentMax Client Trscv Laser Temperature :This OID gives the maximum Laser temperature value among the network lanes of the Client Transceiver, read from the DDM (Di…
1.3.6.1.4.1.20044.76.3.1.209Scalarpmo10010MesrclientNetTxBiasMaxread-onlycurrentMax Client Trscv Laser Bias :This OID gives the maximum Laser bias value among the network lanes of the Client Transceiver, read from the DDM (Digital Diagnost…
1.3.6.1.4.1.20044.76.3.1.210Scalarpmo10010MesrclientNetTxPwrMaxread-onlycurrentMax Client Trscv Tx Power :This OID gives the maximum transmit power value among the network lanes of the Client Transceiver, read from the DDM (Digital Diagno…
1.3.6.1.4.1.20044.76.3.1.211Scalarpmo10010MesrclientNetRxPwrMaxread-onlycurrentMax Client Trscv Rx Power :This OID gives the maximum receive power value among the network lanes of the Client Transceiver, read in the DDM (Digital Diagnosti…
1.3.6.1.4.1.20044.76.3.1.212Scalarpmo10010MesrlineNetTxLaserOutputPwrMaxread-onlycurrentMax Line Trscv Tx Power :This OID gives the maximum Tx Laser transmit power value among the network lanes of the Line Transceiver, read in the DDM (Digital Dia…
1.3.6.1.4.1.20044.76.3.1.213Scalarpmo10010MesrlineNetTxLaserTempMaxread-onlycurrentMax Line Trscv Tx Laser Temperature :This OID gives the maximum Tx Laser Temperature value among the network lanes of the Line Transceiver, read from the DDM (…
1.3.6.1.4.1.20044.76.3.1.214Scalarpmo10010MesrlineNetTxBiasCurrentMaxread-onlycurrentMax Line Trscv Tx Laser Bias :This OID gives the maximum Tx Laser Bias value among the network lanes of the Line Transceiver, read from the DDM (Digital Diagno…
1.3.6.1.4.1.20044.76.3.1.215Scalarpmo10010MesrlineNetRxInputPwrMaxread-onlycurrentMax Line Trscv Rx Power :This OID gives the maximum Receive power value among the network lanes of the Line Transceiver, read in the DDM (Digital Diagnostic Mo…
1.3.6.1.4.1.20044.76.3.1.216Scalarpmo10010MesrlineResidualChromaticDispMaxread-onlycurrentMax Residual Chromatic Dispersion :This OID gives the maximum Residual Chromatic Dispersion on the Line interface since the last measure reset (Unit = ps/nm)<H…
1.3.6.1.4.1.20044.76.3.1.217Scalarpmo10010MesrlineDiffGroupDelayMaxread-onlycurrentMax Differential Group Delay :This OID gives the maximum Differential Group Delay on the Line interface since the last measure reset (Unit = ps)<Help> This mea…
1.3.6.1.4.1.20044.76.3.1.218Scalarpmo10010MesrlineQFactorMaxread-onlycurrentMax Q Factor :This OID gives the maximum Q Factor on the Line interface since the last measure reset (Unit = dB)<Help> This measure gives the maximum Q Factor …
1.3.6.1.4.1.20044.76.3.1.219Scalarpmo10010MesrlineCarrierFreqOffsetMaxread-onlycurrentMax Carrier Frequency Offset :This OID gives the maximum Carrier Frequency Offset on the Line interface since the last measure reset (Unit = Mhz)<Help> This me…
1.3.6.1.4.1.20044.76.3.1.220Scalarpmo10010MesrlineOsnrMaxread-onlycurrentMax OSNR :This OID gives the maximum OSNR on the Line interface since the last measure reset (OSNR = AV/10) (Unit = dB)<Help> This measure gives the maximum OS…
1.3.6.1.4.1.20044.76.3.2Nodepmo10010MesrClient
1.3.6.1.4.1.20044.76.3.2.8Scalarpmo10010MesrclientCfpTempread-onlycurrentClient Trscv Temperature :This OID gives the temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/2…
1.3.6.1.4.1.20044.76.3.2.9Scalarpmo10010MesrclientCfp3v3Voltageread-onlycurrentClient Trscv Voltage :This OID gives the 3V3 voltage value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/1000) (Un…
1.3.6.1.4.1.20044.76.3.2.10Scalarpmo10010MesrclientSoaBiasCurrentread-onlycurrentClient Trscv SOA Bias :This OID gives the SOA bias value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = m…
1.3.6.1.4.1.20044.76.3.2.16Tablepmo10010MesrclientNetTxTempTablenot-accessiblecurrentList of pmo10010MesrclientNetTxTemp Article
1.3.6.1.4.1.20044.76.3.2.16.1Rowpmo10010MesrclientNetTxTempEntrynot-accessiblecurrentRow definition for the pmo10010MesrclientNetTxTemp table
1.3.6.1.4.1.20044.76.3.2.16.1.1Columnpmo10010MesrclientNetTxTempIndexread-onlycurrentIndex definition for the pmo10010MesrclientNetTxTemp table
1.3.6.1.4.1.20044.76.3.2.16.1.2Columnpmo10010MesrclientNetTxTempPortnread-onlycurrentClient Trscv Temperature :This OID gives the Laser temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature …
1.3.6.1.4.1.20044.76.3.2.32Tablepmo10010MesrclientNetTxBiasTablenot-accessiblecurrentList of pmo10010MesrclientNetTxBias Article
1.3.6.1.4.1.20044.76.3.2.32.1Rowpmo10010MesrclientNetTxBiasEntrynot-accessiblecurrentRow definition for the pmo10010MesrclientNetTxBias table
1.3.6.1.4.1.20044.76.3.2.32.1.1Columnpmo10010MesrclientNetTxBiasIndexread-onlycurrentIndex definition for the pmo10010MesrclientNetTxBias table
1.3.6.1.4.1.20044.76.3.2.32.1.2Columnpmo10010MesrclientNetTxBiasPortnread-onlycurrentClient Trscv Laser Bias :This OID gives the Laser bias value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit…
1.3.6.1.4.1.20044.76.3.2.48Tablepmo10010MesrclientNetTxPwrTablenot-accessiblecurrentList of pmo10010MesrclientNetTxPwr Article
1.3.6.1.4.1.20044.76.3.2.48.1Rowpmo10010MesrclientNetTxPwrEntrynot-accessiblecurrentRow definition for the pmo10010MesrclientNetTxPwr table
1.3.6.1.4.1.20044.76.3.2.48.1.1Columnpmo10010MesrclientNetTxPwrIndexread-onlycurrentIndex definition for the pmo10010MesrclientNetTxPwr table
1.3.6.1.4.1.20044.76.3.2.48.1.2Columnpmo10010MesrclientNetTxPwrPortnread-onlycurrentClient Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)…
1.3.6.1.4.1.20044.76.3.2.64Tablepmo10010MesrclientNetRxPwrTablenot-accessiblecurrentList of pmo10010MesrclientNetRxPwr Article
1.3.6.1.4.1.20044.76.3.2.64.1Rowpmo10010MesrclientNetRxPwrEntrynot-accessiblecurrentRow definition for the pmo10010MesrclientNetRxPwr table
1.3.6.1.4.1.20044.76.3.2.64.1.1Columnpmo10010MesrclientNetRxPwrIndexread-onlycurrentIndex definition for the pmo10010MesrclientNetRxPwr table
1.3.6.1.4.1.20044.76.3.2.64.1.2Columnpmo10010MesrclientNetRxPwrPortnread-onlycurrentClient Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40…
1.3.6.1.4.1.20044.76.3.3Nodepmo10010MesrLine
1.3.6.1.4.1.20044.76.3.3.12Scalarpmo10010MesrlineMsaTempread-onlycurrentLine Trscv Temperature :This OID gives the temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) …
1.3.6.1.4.1.20044.76.3.3.13Scalarpmo10010MesrlineMsa3v3Voltageread-onlycurrentLine Trscv Voltage :This OID gives the 3V3 voltage value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/1000) (Unit =…
1.3.6.1.4.1.20044.76.3.3.14Scalarpmo10010MesrlineSoaBiasCurrentread-onlycurrentLine Trscv SOA Bias :This OID gives the SOA bias value of the Line Transceiver,read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <H…
1.3.6.1.4.1.20044.76.3.3.80Tablepmo10010MesrlineNetTxLaserOutputPwrTablenot-accessiblecurrentList of pmo10010MesrlineNetTxLaserOutputPwr Article
1.3.6.1.4.1.20044.76.3.3.80.1Rowpmo10010MesrlineNetTxLaserOutputPwrEntrynot-accessiblecurrentRow definition for the pmo10010MesrlineNetTxLaserOutputPwr table
1.3.6.1.4.1.20044.76.3.3.80.1.1Columnpmo10010MesrlineNetTxLaserOutputPwrIndexread-onlycurrentIndex definition for the pmo10010MesrlineNetTxLaserOutputPwr table
1.3.6.1.4.1.20044.76.3.3.80.1.2Columnpmo10010MesrlineNetTxLaserOutputPwrPortnread-onlycurrentCurrent Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power =…
1.3.6.1.4.1.20044.76.3.3.96Tablepmo10010MesrlineNetTxLaserTempTablenot-accessiblecurrentList of pmo10010MesrlineNetTxLaserTemp Article
1.3.6.1.4.1.20044.76.3.3.96.1Rowpmo10010MesrlineNetTxLaserTempEntrynot-accessiblecurrentRow definition for the pmo10010MesrlineNetTxLaserTemp table
1.3.6.1.4.1.20044.76.3.3.96.1.1Columnpmo10010MesrlineNetTxLaserTempIndexread-onlycurrentIndex definition for the pmo10010MesrlineNetTxLaserTemp table
1.3.6.1.4.1.20044.76.3.3.96.1.2Columnpmo10010MesrlineNetTxLaserTempPortnread-onlycurrentCurrent Line Trscv Tx Laser Temperature :This OID gives the Tx Laser Temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitorin…
1.3.6.1.4.1.20044.76.3.3.112Tablepmo10010MesrlineNetTxBiasCurrentTablenot-accessiblecurrentList of pmo10010MesrlineNetTxBiasCurrent Article
1.3.6.1.4.1.20044.76.3.3.112.1Rowpmo10010MesrlineNetTxBiasCurrentEntrynot-accessiblecurrentRow definition for the pmo10010MesrlineNetTxBiasCurrent table
1.3.6.1.4.1.20044.76.3.3.112.1.1Columnpmo10010MesrlineNetTxBiasCurrentIndexread-onlycurrentIndex definition for the pmo10010MesrlineNetTxBiasCurrent table
1.3.6.1.4.1.20044.76.3.3.112.1.2Columnpmo10010MesrlineNetTxBiasCurrentPortnread-onlycurrentCurrent Line Trscv Tx Laser Bias :This OID gives the Tx Laser Bias value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/…
1.3.6.1.4.1.20044.76.3.3.128Tablepmo10010MesrlineNetRxInputPwrTablenot-accessiblecurrentList of pmo10010MesrlineNetRxInputPwr Article
1.3.6.1.4.1.20044.76.3.3.128.1Rowpmo10010MesrlineNetRxInputPwrEntrynot-accessiblecurrentRow definition for the pmo10010MesrlineNetRxInputPwr table
1.3.6.1.4.1.20044.76.3.3.128.1.1Columnpmo10010MesrlineNetRxInputPwrIndexread-onlycurrentIndex definition for the pmo10010MesrlineNetRxInputPwr table
1.3.6.1.4.1.20044.76.3.3.128.1.2Columnpmo10010MesrlineNetRxInputPwrPortnread-onlycurrentCurrent Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (…
1.3.6.1.4.1.20044.76.3.3.144Tablepmo10010MesrlineResidualChromaticDispTablenot-accessiblecurrentList of pmo10010MesrlineResidualChromaticDisp Article
1.3.6.1.4.1.20044.76.3.3.144.1Rowpmo10010MesrlineResidualChromaticDispEntrynot-accessiblecurrentRow definition for the pmo10010MesrlineResidualChromaticDisp table
1.3.6.1.4.1.20044.76.3.3.144.1.1Columnpmo10010MesrlineResidualChromaticDispIndexread-onlycurrentIndex definition for the pmo10010MesrlineResidualChromaticDisp table
1.3.6.1.4.1.20044.76.3.3.144.1.2Columnpmo10010MesrlineResidualChromaticDispPortnread-onlycurrentCurrent Residual Chromatic Dispersion :This OID gives the current Residual Chromatic Dispersion on the Line interface (Unit = ps/nm)<Help> This measure gives t…
1.3.6.1.4.1.20044.76.3.3.148Tablepmo10010MesrlineDiffGroupDelayTablenot-accessiblecurrentList of pmo10010MesrlineDiffGroupDelay Article
1.3.6.1.4.1.20044.76.3.3.148.1Rowpmo10010MesrlineDiffGroupDelayEntrynot-accessiblecurrentRow definition for the pmo10010MesrlineDiffGroupDelay table
1.3.6.1.4.1.20044.76.3.3.148.1.1Columnpmo10010MesrlineDiffGroupDelayIndexread-onlycurrentIndex definition for the pmo10010MesrlineDiffGroupDelay table
1.3.6.1.4.1.20044.76.3.3.148.1.2Columnpmo10010MesrlineDiffGroupDelayPortnread-onlycurrentCurrent Differential Group Delay :This OID gives the current Differential Group Delay on the Line interface (Unit = ps)<Help> This measure gives the current Di…
1.3.6.1.4.1.20044.76.3.3.152Tablepmo10010MesrlineQFactorTablenot-accessiblecurrentList of pmo10010MesrlineQFactor Article
1.3.6.1.4.1.20044.76.3.3.152.1Rowpmo10010MesrlineQFactorEntrynot-accessiblecurrentRow definition for the pmo10010MesrlineQFactor table
1.3.6.1.4.1.20044.76.3.3.152.1.1Columnpmo10010MesrlineQFactorIndexread-onlycurrentIndex definition for the pmo10010MesrlineQFactor table
1.3.6.1.4.1.20044.76.3.3.152.1.2Columnpmo10010MesrlineQFactorPortnread-onlycurrentCurrent Q Factor :This OID gives the current Q Factor on the Line interface (Unit = dB) <Help> This measure gives the current Q Factor on the Line interface.
1.3.6.1.4.1.20044.76.3.3.156Tablepmo10010MesrlineCarrierFreqOffsetTablenot-accessiblecurrentList of pmo10010MesrlineCarrierFreqOffset Article
1.3.6.1.4.1.20044.76.3.3.156.1Rowpmo10010MesrlineCarrierFreqOffsetEntrynot-accessiblecurrentRow definition for the pmo10010MesrlineCarrierFreqOffset table
1.3.6.1.4.1.20044.76.3.3.156.1.1Columnpmo10010MesrlineCarrierFreqOffsetIndexread-onlycurrentIndex definition for the pmo10010MesrlineCarrierFreqOffset table
1.3.6.1.4.1.20044.76.3.3.156.1.2Columnpmo10010MesrlineCarrierFreqOffsetPortnread-onlycurrentCurrent Carrier Frequency Offset :This OID gives the current Carrier Frequency Offset on the Line interface (Unit = Mhz)<Help> This measure gives the current C…
1.3.6.1.4.1.20044.76.3.3.160Tablepmo10010MesrlineOsnrTablenot-accessiblecurrentList of pmo10010MesrlineOsnr Article
1.3.6.1.4.1.20044.76.3.3.160.1Rowpmo10010MesrlineOsnrEntrynot-accessiblecurrentRow definition for the pmo10010MesrlineOsnr table
1.3.6.1.4.1.20044.76.3.3.160.1.1Columnpmo10010MesrlineOsnrIndexread-onlycurrentIndex definition for the pmo10010MesrlineOsnr table
1.3.6.1.4.1.20044.76.3.3.160.1.2Columnpmo10010MesrlineOsnrPortnread-onlycurrentCurrent OSNR :This OID gives the current OSNR on the Line interface (OSNR = AV/10) (Unit = dB)<Help> This measure gives the current OSNR on the Line interface.
1.3.6.1.4.1.20044.76.4Nodepmo10010counters
1.3.6.1.4.1.20044.76.4.1Nodepmo10010CntOther
1.3.6.1.4.1.20044.76.4.2Nodepmo10010CntClient
1.3.6.1.4.1.20044.76.4.2.16Tablepmo10010CntclientInputErrorCounterLaneOneTablenot-accessiblecurrentList of pmo10010CntclientInputErrorCounterLaneOne Article
1.3.6.1.4.1.20044.76.4.2.16.1Rowpmo10010CntclientInputErrorCounterLaneOneEntrynot-accessiblecurrentRow definition for the pmo10010CntclientInputErrorCounterLaneOne table
1.3.6.1.4.1.20044.76.4.2.16.1.1Columnpmo10010CntclientInputErrorCounterLaneOneIndexread-onlycurrentIndex definition for the pmo10010CntclientInputErrorCounterLaneOne table
1.3.6.1.4.1.20044.76.4.2.16.1.2Columnpmo10010CntclientInputErrorCounterLaneOneValuePortnread-onlycurrentClient_Input_Error_Counter_Lane1 :This counter is incremented each time a coding violation is detected on the host lane of the client transceiver <Help> This c…
1.3.6.1.4.1.20044.76.4.2.16.1.3Columnpmo10010CntclientInputErrorCounterLaneOneErrorPortnread-onlycurrentClient Input Counter Error :This OID when set indicates the rate adaptation removal counter value is invalid on Port
1.3.6.1.4.1.20044.76.4.2.16.1.4Columnpmo10010CntclientInputErrorCounterLaneOneOverloadPortnread-onlycurrentClient Input Counter Overload :This OID when set indicates a rate adaptation removal counter overload on Port
1.3.6.1.4.1.20044.76.4.2.32Tablepmo10010CntclientInputErrorCounterLaneTwoTablenot-accessiblecurrentList of pmo10010CntclientInputErrorCounterLaneTwo Article
1.3.6.1.4.1.20044.76.4.2.32.1Rowpmo10010CntclientInputErrorCounterLaneTwoEntrynot-accessiblecurrentRow definition for the pmo10010CntclientInputErrorCounterLaneTwo table
1.3.6.1.4.1.20044.76.4.2.32.1.1Columnpmo10010CntclientInputErrorCounterLaneTwoIndexread-onlycurrentIndex definition for the pmo10010CntclientInputErrorCounterLaneTwo table
1.3.6.1.4.1.20044.76.4.2.32.1.2Columnpmo10010CntclientInputErrorCounterLaneTwoValuePortnread-onlycurrentClient_Input_Error_Counter_Lane2 :This counter is incremented each time a coding violation is detected on the host lane of the client transceiver <Help> This c…
1.3.6.1.4.1.20044.76.4.2.32.1.3Columnpmo10010CntclientInputErrorCounterLaneTwoErrorPortnread-onlycurrentClient Input Counter Error :This OID when set indicates the client error counter value is invalid on Port
1.3.6.1.4.1.20044.76.4.2.32.1.4Columnpmo10010CntclientInputErrorCounterLaneTwoOverloadPortnread-onlycurrentClient Input Counter Overload :This OID when set indicates a client input error counter overload on Port
1.3.6.1.4.1.20044.76.4.2.80Tablepmo10010CntclientInputErrorCounterTablenot-accessiblecurrentList of pmo10010CntclientInputErrorCounter Article
1.3.6.1.4.1.20044.76.4.2.80.1Rowpmo10010CntclientInputErrorCounterEntrynot-accessiblecurrentRow definition for the pmo10010CntclientInputErrorCounter table
1.3.6.1.4.1.20044.76.4.2.80.1.1Columnpmo10010CntclientInputErrorCounterIndexread-onlycurrentIndex definition for the pmo10010CntclientInputErrorCounter table
1.3.6.1.4.1.20044.76.4.2.80.1.2Columnpmo10010CntclientInputErrorCounterValuePortnread-onlycurrentClient Input Errors :This counter is increased each time an error is detected on the Client input stream <Help> This counter gives the number of CBIP errors (a…
1.3.6.1.4.1.20044.76.4.2.80.1.3Columnpmo10010CntclientInputErrorCounterErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the client error counter value is invalid on Port
1.3.6.1.4.1.20044.76.4.2.80.1.4Columnpmo10010CntclientInputErrorCounterOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a client input error counter overload on Port
1.3.6.1.4.1.20044.76.4.2.96Tablepmo10010CntclientOutputErrorCounterTablenot-accessiblecurrentList of pmo10010CntclientOutputErrorCounter Article
1.3.6.1.4.1.20044.76.4.2.96.1Rowpmo10010CntclientOutputErrorCounterEntrynot-accessiblecurrentRow definition for the pmo10010CntclientOutputErrorCounter table
1.3.6.1.4.1.20044.76.4.2.96.1.1Columnpmo10010CntclientOutputErrorCounterIndexread-onlycurrentIndex definition for the pmo10010CntclientOutputErrorCounter table
1.3.6.1.4.1.20044.76.4.2.96.1.2Columnpmo10010CntclientOutputErrorCounterValuePortnread-onlycurrentClient Output Errors :This counter is increased each time an error is detected on the Client output stream <Help> This counter gives the number of CBIP errors …
1.3.6.1.4.1.20044.76.4.2.96.1.3Columnpmo10010CntclientOutputErrorCounterErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the client error counter value is invalid on Port
1.3.6.1.4.1.20044.76.4.2.96.1.4Columnpmo10010CntclientOutputErrorCounterOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a client input error counter overload on Port
1.3.6.1.4.1.20044.76.4.3Nodepmo10010CntLine
1.3.6.1.4.1.20044.76.4.3.192Tablepmo10010CntlocalLineSmBlockErrorCounterTablenot-accessiblecurrentList of pmo10010CntlocalLineSmBlockErrorCounter Article
1.3.6.1.4.1.20044.76.4.3.192.1Rowpmo10010CntlocalLineSmBlockErrorCounterEntrynot-accessiblecurrentRow definition for the pmo10010CntlocalLineSmBlockErrorCounter table
1.3.6.1.4.1.20044.76.4.3.192.1.1Columnpmo10010CntlocalLineSmBlockErrorCounterIndexread-onlycurrentIndex definition for the pmo10010CntlocalLineSmBlockErrorCounter table
1.3.6.1.4.1.20044.76.4.3.192.1.2Columnpmo10010CntlocalLineSmBlockErrorCounterValuePortnread-onlycurrentLine Input SM-Block Errors :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC <Help> This counter gives the current Bit Error Rate (…
1.3.6.1.4.1.20044.76.4.3.192.1.3Columnpmo10010CntlocalLineSmBlockErrorCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the B1 error counter value is invalid on Port
1.3.6.1.4.1.20044.76.4.3.192.1.4Columnpmo10010CntlocalLineSmBlockErrorCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a B1 error counter overload on Port
1.3.6.1.4.1.20044.76.4.3.193Tablepmo10010CntlocalLineFecCorrectedErrorsCounterTablenot-accessiblecurrentList of pmo10010CntlocalLineFecCorrectedErrorsCounter Article
1.3.6.1.4.1.20044.76.4.3.193.1Rowpmo10010CntlocalLineFecCorrectedErrorsCounterEntrynot-accessiblecurrentRow definition for the pmo10010CntlocalLineFecCorrectedErrorsCounter table
1.3.6.1.4.1.20044.76.4.3.193.1.1Columnpmo10010CntlocalLineFecCorrectedErrorsCounterIndexread-onlycurrentIndex definition for the pmo10010CntlocalLineFecCorrectedErrorsCounter table
1.3.6.1.4.1.20044.76.4.3.193.1.2Columnpmo10010CntlocalLineFecCorrectedErrorsCounterValuePortnread-onlycurrentLine Input FEC Corrected Errors :This OID gives the current Bit Error Rate before the Hard Decision FEC <Help> This counter gives the current Bit Error Rate be…
1.3.6.1.4.1.20044.76.4.3.193.1.3Columnpmo10010CntlocalLineFecCorrectedErrorsCounterErrorPortnread-onlycurrentFEC Counter Error :This bit when set indicates the FEC corrected errors counter value is invalid on Line
1.3.6.1.4.1.20044.76.4.3.193.1.4Columnpmo10010CntlocalLineFecCorrectedErrorsCounterOverloadPortnread-onlycurrentFEC Counter Overload :This bit when set indicates a FEC corrected errors counter overload on Line
1.3.6.1.4.1.20044.76.4.3.194Tablepmo10010CntremoteLineSmBlockErrorCounterTablenot-accessiblecurrentList of pmo10010CntremoteLineSmBlockErrorCounter Article
1.3.6.1.4.1.20044.76.4.3.194.1Rowpmo10010CntremoteLineSmBlockErrorCounterEntrynot-accessiblecurrentRow definition for the pmo10010CntremoteLineSmBlockErrorCounter table
1.3.6.1.4.1.20044.76.4.3.194.1.1Columnpmo10010CntremoteLineSmBlockErrorCounterIndexread-onlycurrentIndex definition for the pmo10010CntremoteLineSmBlockErrorCounter table
1.3.6.1.4.1.20044.76.4.3.194.1.2Columnpmo10010CntremoteLineSmBlockErrorCounterValuePortnread-onlycurrentRemote SM Block Errors :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC on the remote side <Help> This counter gives the current B…
1.3.6.1.4.1.20044.76.4.3.194.1.3Columnpmo10010CntremoteLineSmBlockErrorCounterErrorPortnread-onlycurrentRemote Counter Error :This bit when set indicates the FEC corrected errors counter value is invalid on Line
1.3.6.1.4.1.20044.76.4.3.194.1.4Columnpmo10010CntremoteLineSmBlockErrorCounterOverloadPortnread-onlycurrentRemote Counter Overload :This bit when set indicates a FEC corrected errors counter overload on Line
1.3.6.1.4.1.20044.76.4.3.195Tablepmo10010CntlineDfrmTimCntTablenot-accessiblecurrentList of pmo10010CntlineDfrmTimCnt Article
1.3.6.1.4.1.20044.76.4.3.195.1Rowpmo10010CntlineDfrmTimCntEntrynot-accessiblecurrentRow definition for the pmo10010CntlineDfrmTimCnt table
1.3.6.1.4.1.20044.76.4.3.195.1.1Columnpmo10010CntlineDfrmTimCntIndexread-onlycurrentIndex definition for the pmo10010CntlineDfrmTimCnt table
1.3.6.1.4.1.20044.76.4.3.195.1.2Columnpmo10010CntlineDfrmTimCntValuePortnread-onlycurrentLine Timer Counter :
1.3.6.1.4.1.20044.76.4.3.195.1.3Columnpmo10010CntlineDfrmTimCntErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.76.4.3.195.1.4Columnpmo10010CntlineDfrmTimCntOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.76.4.3.196Tablepmo10010CntlocalLineTrscvFecCorrectedErrorCounterTablenot-accessiblecurrentList of pmo10010CntlocalLineTrscvFecCorrectedErrorCounter Article
1.3.6.1.4.1.20044.76.4.3.196.1Rowpmo10010CntlocalLineTrscvFecCorrectedErrorCounterEntrynot-accessiblecurrentRow definition for the pmo10010CntlocalLineTrscvFecCorrectedErrorCounter table
1.3.6.1.4.1.20044.76.4.3.196.1.1Columnpmo10010CntlocalLineTrscvFecCorrectedErrorCounterIndexread-onlycurrentIndex definition for the pmo10010CntlocalLineTrscvFecCorrectedErrorCounter table
1.3.6.1.4.1.20044.76.4.3.196.1.2Columnpmo10010CntlocalLineTrscvFecCorrectedErrorCounterValuePortnread-onlycurrentLine Input SD FEC Corrected Errors :This OID gives the current Bit Error Rate before the Soft Decision FEC <Help> This counter gives the current Bit Error Rate…
1.3.6.1.4.1.20044.76.4.3.196.1.3Columnpmo10010CntlocalLineTrscvFecCorrectedErrorCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.76.4.3.196.1.4Columnpmo10010CntlocalLineTrscvFecCorrectedErrorCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.76.4.3.197Tablepmo10010CntlocalLineTrscvFecUncorrectedErrorCounterTablenot-accessiblecurrentList of pmo10010CntlocalLineTrscvFecUncorrectedErrorCounter Article
1.3.6.1.4.1.20044.76.4.3.197.1Rowpmo10010CntlocalLineTrscvFecUncorrectedErrorCounterEntrynot-accessiblecurrentRow definition for the pmo10010CntlocalLineTrscvFecUncorrectedErrorCounter table
1.3.6.1.4.1.20044.76.4.3.197.1.1Columnpmo10010CntlocalLineTrscvFecUncorrectedErrorCounterIndexread-onlycurrentIndex definition for the pmo10010CntlocalLineTrscvFecUncorrectedErrorCounter table
1.3.6.1.4.1.20044.76.4.3.197.1.2Columnpmo10010CntlocalLineTrscvFecUncorrectedErrorCounterValuePortnread-onlycurrentSD Uncorrected :This OID gives the current Bit Error Rate after the Soft Decision FEC (residual) <Help> This counter gives the current Bit Error Rate after the…
1.3.6.1.4.1.20044.76.4.3.197.1.3Columnpmo10010CntlocalLineTrscvFecUncorrectedErrorCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.76.4.3.197.1.4Columnpmo10010CntlocalLineTrscvFecUncorrectedErrorCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.76.4.3.200Tablepmo10010CntlocalLinePmBlockErrorCounterTablenot-accessiblecurrentList of pmo10010CntlocalLinePmBlockErrorCounter Article
1.3.6.1.4.1.20044.76.4.3.200.1Rowpmo10010CntlocalLinePmBlockErrorCounterEntrynot-accessiblecurrentRow definition for the pmo10010CntlocalLinePmBlockErrorCounter table
1.3.6.1.4.1.20044.76.4.3.200.1.1Columnpmo10010CntlocalLinePmBlockErrorCounterIndexread-onlycurrentIndex definition for the pmo10010CntlocalLinePmBlockErrorCounter table
1.3.6.1.4.1.20044.76.4.3.200.1.2Columnpmo10010CntlocalLinePmBlockErrorCounterValuePortnread-onlycurrentLine Input PM Block Errors :This OID gives the PM B1 errors counted as block errors <Help> This counter gives the PM B1 errors counted as block errors
1.3.6.1.4.1.20044.76.4.3.200.1.3Columnpmo10010CntlocalLinePmBlockErrorCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.76.4.3.200.1.4Columnpmo10010CntlocalLinePmBlockErrorCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.76.4.3.201Tablepmo10010CntremoteLinePmBlockErrorCounterTablenot-accessiblecurrentList of pmo10010CntremoteLinePmBlockErrorCounter Article
1.3.6.1.4.1.20044.76.4.3.201.1Rowpmo10010CntremoteLinePmBlockErrorCounterEntrynot-accessiblecurrentRow definition for the pmo10010CntremoteLinePmBlockErrorCounter table
1.3.6.1.4.1.20044.76.4.3.201.1.1Columnpmo10010CntremoteLinePmBlockErrorCounterIndexread-onlycurrentIndex definition for the pmo10010CntremoteLinePmBlockErrorCounter table
1.3.6.1.4.1.20044.76.4.3.201.1.2Columnpmo10010CntremoteLinePmBlockErrorCounterValuePortnread-onlycurrentRemote PM Block Errors :This OID gives the PM Remote Error Indication counted as block errorsPM Remote Error Indication counted as block errors
1.3.6.1.4.1.20044.76.4.3.201.1.3Columnpmo10010CntremoteLinePmBlockErrorCounterErrorPortnread-onlycurrentRemote Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.76.4.3.201.1.4Columnpmo10010CntremoteLinePmBlockErrorCounterOverloadPortnread-onlycurrentRemote Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.76.6Nodepmo10010controlsWrite
1.3.6.1.4.1.20044.76.6.1Nodepmo10010CtrlOther
1.3.6.1.4.1.20044.76.6.1.1Nodepmo10010CtrlconfMgnt1
1.3.6.1.4.1.20044.76.6.1.1.1Scalarpmo10010CtrlConf1Load1read-writecurrentLoad Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM.
1.3.6.1.4.1.20044.76.6.1.1.2Scalarpmo10010CtrlConf2Load1read-writecurrentLoad Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM.
1.3.6.1.4.1.20044.76.6.1.1.10Scalarpmo10010CtrlConf2Flash1read-writecurrentWrite Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura…
1.3.6.1.4.1.20044.76.6.1.1.14Scalarpmo10010CtrlConf2Clear1read-writecurrentClear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o…
1.3.6.1.4.1.20044.76.6.1.4Nodepmo10010Ctrlsynth4
1.3.6.1.4.1.20044.76.6.1.4.1Scalarpmo10010CtrlCorrelatOnread-writecurrentEnable Alarm Correlation :This OID enables the alarm correlation in the PM.
1.3.6.1.4.1.20044.76.6.1.4.2Scalarpmo10010CtrlCorrelatOffread-writecurrentDisable Alarm Correlation :This OID disables the alarm correlation in the PM.
1.3.6.1.4.1.20044.76.6.1.5Nodepmo10010CtrlswMgnt
1.3.6.1.4.1.20044.76.6.1.5.2Scalarpmo10010CtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> …
1.3.6.1.4.1.20044.76.6.1.5.3Scalarpmo10010CtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th…
1.3.6.1.4.1.20044.76.6.1.5.5Scalarpmo10010CtrlLoadSwBank1read-writecurrentSet Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW…
1.3.6.1.4.1.20044.76.6.1.5.6Scalarpmo10010CtrlLoadSwBank2read-writecurrentSet Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S…
1.3.6.1.4.1.20044.76.6.1.6Nodepmo10010CtrlgwMgnt
1.3.6.1.4.1.20044.76.6.1.6.1Scalarpmo10010CtrlCurrentGwResetread-writecurrentActive Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting.
1.3.6.1.4.1.20044.76.6.1.6.5Scalarpmo10010CtrlLoadGwBank1read-writecurrentSet Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.76.6.1.6.6Scalarpmo10010CtrlLoadGwBank2read-writecurrentSet Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.76.6.1.6.7Scalarpmo10010CtrlLoadGwBank3read-writecurrentSet Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.76.6.1.6.8Scalarpmo10010CtrlLoadGwBank4read-writecurrentSet Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.76.6.1.192Nodepmo10010CtrlledTest
1.3.6.1.4.1.20044.76.6.1.192.1Scalarpmo10010CtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.76.6.1.192.2Scalarpmo10010CtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.76.6.1.192.3Scalarpmo10010CtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.76.6.1.201Nodepmo10010CtrlinitSwitchMarvell
1.3.6.1.4.1.20044.76.6.1.201.1Scalarpmo10010CtrlInitSwitchMarvellread-writecurrentSwitch Initialization :This OID operates an initialization of the switch managed through the module <Help> This control activates an initialization of the swit…
1.3.6.1.4.1.20044.76.6.1.259Nodepmo10010CtrlresetCount
1.3.6.1.4.1.20044.76.6.1.259.1Scalarpmo10010CtrlResetcountread-writecurrentModule Count Global Reset :This OID resets all the errors counters on the module <Help > This control initiates a reset of the errors counters on the module
1.3.6.1.4.1.20044.76.6.1.260Nodepmo10010CtrlresetRmon
1.3.6.1.4.1.20044.76.6.1.260.1Scalarpmo10010CtrlResetrmonread-writecurrentModule Rmon Global Reset :This OID resets all the Rmon counters on the module <Help > This control initiates a reset of the Rmon counters on the module
1.3.6.1.4.1.20044.76.6.1.261Nodepmo10010CtrlresetMeasurements
1.3.6.1.4.1.20044.76.6.1.261.1Scalarpmo10010CtrlResetmeasurementsread-writecurrentManagement Meas Global Reset :This OID resets some measurements on the management <Help > This control initiates a reset of some measurements on the management
1.3.6.1.4.1.20044.76.6.2Nodepmo10010CtrlClient
1.3.6.1.4.1.20044.76.6.2.16Tablepmo10010CtrlaccessLoopTablenot-accessiblecurrentList of pmo10010CtrlaccessLoop Article
1.3.6.1.4.1.20044.76.6.2.16.1Rowpmo10010CtrlaccessLoopEntrynot-accessiblecurrentRow definition for the pmo10010CtrlaccessLoop table
1.3.6.1.4.1.20044.76.6.2.16.1.1Columnpmo10010CtrlaccessLoopIndexread-onlycurrentIndex definition for the pmo10010CtrlaccessLoop table
1.3.6.1.4.1.20044.76.6.2.16.1.2Columnpmo10010CtrlaccessLoopPortnread-writecurrentClient Facility Loopback :This OID, when set at '1' puts the client port in loopback, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. <Help…
1.3.6.1.4.1.20044.76.6.2.17Tablepmo10010CtrlclientLoopToLineTablenot-accessiblecurrentList of pmo10010CtrlclientLoopToLine Article
1.3.6.1.4.1.20044.76.6.2.17.1Rowpmo10010CtrlclientLoopToLineEntrynot-accessiblecurrentRow definition for the pmo10010CtrlclientLoopToLine table
1.3.6.1.4.1.20044.76.6.2.17.1.1Columnpmo10010CtrlclientLoopToLineIndexread-onlycurrentIndex definition for the pmo10010CtrlclientLoopToLine table
1.3.6.1.4.1.20044.76.6.2.17.1.2Columnpmo10010CtrlclientLoopToLinePortnread-writecurrentClient Terminal Loopback :This OID, when set, puts the client port in loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.<Help> This control ena…
1.3.6.1.4.1.20044.76.6.2.21Tablepmo10010CtrlcsfUpInsTablenot-accessiblecurrentList of pmo10010CtrlcsfUpIns Article
1.3.6.1.4.1.20044.76.6.2.21.1Rowpmo10010CtrlcsfUpInsEntrynot-accessiblecurrentRow definition for the pmo10010CtrlcsfUpIns table
1.3.6.1.4.1.20044.76.6.2.21.1.1Columnpmo10010CtrlcsfUpInsIndexread-onlycurrentIndex definition for the pmo10010CtrlcsfUpIns table
1.3.6.1.4.1.20044.76.6.2.21.1.2Columnpmo10010CtrlcsfUpInsPortnread-writecurrentClient Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo…
1.3.6.1.4.1.20044.76.6.2.22Tablepmo10010CtrlcaisDwInsTablenot-accessiblecurrentList of pmo10010CtrlcaisDwIns Article
1.3.6.1.4.1.20044.76.6.2.22.1Rowpmo10010CtrlcaisDwInsEntrynot-accessiblecurrentRow definition for the pmo10010CtrlcaisDwIns table
1.3.6.1.4.1.20044.76.6.2.22.1.1Columnpmo10010CtrlcaisDwInsIndexread-onlycurrentIndex definition for the pmo10010CtrlcaisDwIns table
1.3.6.1.4.1.20044.76.6.2.22.1.2Columnpmo10010CtrlcaisDwInsPortnread-writecurrentClient AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port
1.3.6.1.4.1.20044.76.6.3Nodepmo10010CtrlLine
1.3.6.1.4.1.20044.76.6.3.64Tablepmo10010CtrlcommAccessLoopTablenot-accessiblecurrentList of pmo10010CtrlcommAccessLoop Article
1.3.6.1.4.1.20044.76.6.3.64.1Rowpmo10010CtrlcommAccessLoopEntrynot-accessiblecurrentRow definition for the pmo10010CtrlcommAccessLoop table
1.3.6.1.4.1.20044.76.6.3.64.1.1Columnpmo10010CtrlcommAccessLoopIndexread-onlycurrentIndex definition for the pmo10010CtrlcommAccessLoop table
1.3.6.1.4.1.20044.76.6.3.64.1.2Columnpmo10010CtrlcommAccessLoopPortnread-writecurrentLine Terminal Loopback :This OID, when set, puts the module in common access loop back, looping the 100 Gb/s output signal on the 100 Gb/s input.<Help> This co…
1.3.6.1.4.1.20044.76.6.3.66Tablepmo10010CtrllineLoopTablenot-accessiblecurrentList of pmo10010CtrllineLoop Article
1.3.6.1.4.1.20044.76.6.3.66.1Rowpmo10010CtrllineLoopEntrynot-accessiblecurrentRow definition for the pmo10010CtrllineLoop table
1.3.6.1.4.1.20044.76.6.3.66.1.1Columnpmo10010CtrllineLoopIndexread-onlycurrentIndex definition for the pmo10010CtrllineLoop table
1.3.6.1.4.1.20044.76.6.3.66.1.2Columnpmo10010CtrllineLoopPortnread-writecurrentLine Facility Loopback :This OID, when set at '1' puts the module in line loopback mode, looping the received 100 Gb/s signal on the transmit 100 Gb/s output. …
1.3.6.1.4.1.20044.76.6.3.69Tablepmo10010CtrlfecDisableTablenot-accessiblecurrentList of pmo10010CtrlfecDisable Article
1.3.6.1.4.1.20044.76.6.3.69.1Rowpmo10010CtrlfecDisableEntrynot-accessiblecurrentRow definition for the pmo10010CtrlfecDisable table
1.3.6.1.4.1.20044.76.6.3.69.1.1Columnpmo10010CtrlfecDisableIndexread-onlycurrentIndex definition for the pmo10010CtrlfecDisable table
1.3.6.1.4.1.20044.76.6.3.69.1.2Columnpmo10010CtrlfecDisablePortnread-writecurrentForward Error Correction Inhibition :This OID, when set, inhibits the Forward Error Correction feature on the line input <Help> This control enables/disables t…
1.3.6.1.4.1.20044.76.6.3.209Tablepmo10010CtrlmsaLineLoopTablenot-accessiblecurrentList of pmo10010CtrlmsaLineLoop Article
1.3.6.1.4.1.20044.76.6.3.209.1Rowpmo10010CtrlmsaLineLoopEntrynot-accessiblecurrentRow definition for the pmo10010CtrlmsaLineLoop table
1.3.6.1.4.1.20044.76.6.3.209.1.1Columnpmo10010CtrlmsaLineLoopIndexread-onlycurrentIndex definition for the pmo10010CtrlmsaLineLoop table
1.3.6.1.4.1.20044.76.6.3.209.1.2Columnpmo10010CtrlmsaLineLoopPortnread-writecurrentMSA Line Loop :This OID operates a line loopback on the MSA Line <Help> This control defines the line loop back of the line transceiver
1.3.6.1.4.1.20044.76.6.3.210Tablepmo10010CtrlmsaTxResetTablenot-accessiblecurrentList of pmo10010CtrlmsaTxReset Article
1.3.6.1.4.1.20044.76.6.3.210.1Rowpmo10010CtrlmsaTxResetEntrynot-accessiblecurrentRow definition for the pmo10010CtrlmsaTxReset table
1.3.6.1.4.1.20044.76.6.3.210.1.1Columnpmo10010CtrlmsaTxResetIndexread-onlycurrentIndex definition for the pmo10010CtrlmsaTxReset table
1.3.6.1.4.1.20044.76.6.3.210.1.2Columnpmo10010CtrlmsaTxResetPortnread-writecurrentLine MSA TX Reset :This OID resets the TX portion of the MSA line module <Help > This control initiates a reset of the transmitting side
1.3.6.1.4.1.20044.76.6.3.211Tablepmo10010CtrlmsaRxResetTablenot-accessiblecurrentList of pmo10010CtrlmsaRxReset Article
1.3.6.1.4.1.20044.76.6.3.211.1Rowpmo10010CtrlmsaRxResetEntrynot-accessiblecurrentRow definition for the pmo10010CtrlmsaRxReset table
1.3.6.1.4.1.20044.76.6.3.211.1.1Columnpmo10010CtrlmsaRxResetIndexread-onlycurrentIndex definition for the pmo10010CtrlmsaRxReset table
1.3.6.1.4.1.20044.76.6.3.211.1.2Columnpmo10010CtrlmsaRxResetPortnread-writecurrentLine MSA RX Reset :This OID resets the RX portion of the MSA line module <Help > This control initiates a reset of the receiving side
1.3.6.1.4.1.20044.76.6.3.212Tablepmo10010CtrlmsaShutdownTablenot-accessiblecurrentList of pmo10010CtrlmsaShutdown Article
1.3.6.1.4.1.20044.76.6.3.212.1Rowpmo10010CtrlmsaShutdownEntrynot-accessiblecurrentRow definition for the pmo10010CtrlmsaShutdown table
1.3.6.1.4.1.20044.76.6.3.212.1.1Columnpmo10010CtrlmsaShutdownIndexread-onlycurrentIndex definition for the pmo10010CtrlmsaShutdown table
1.3.6.1.4.1.20044.76.6.3.212.1.2Columnpmo10010CtrlmsaShutdownPortnread-writecurrentLine MSA Shutdown :This OID enters a process to shutdown the MSA line module <Help > This control initiates a shutdown of the module
1.3.6.1.4.1.20044.76.7Nodepmo10010ri
1.3.6.1.4.1.20044.76.7.1Nodepmo10010riTable
1.3.6.1.4.1.20044.76.7.1.1Tablepmo10010RinvSfpTablenot-accessiblecurrentList of the SFPs on the selected module
1.3.6.1.4.1.20044.76.7.1.1.1Rowpmo10010RinvSfpEntrynot-accessiblecurrentRow definition for the SFP table
1.3.6.1.4.1.20044.76.7.1.1.1.1Columnpmo10010RinvSfpIndexread-onlycurrentIndex for SFP table
1.3.6.1.4.1.20044.76.7.1.1.1.2Columnpmo10010Rinvsfpread-onlycurrentInventory for the SFP: This OID contains the inventory for the SFP
1.3.6.1.4.1.20044.76.7.1.2Tablepmo10010RinvLineTablenot-accessiblecurrentList of the XFPs on the selected module
1.3.6.1.4.1.20044.76.7.1.2.1Rowpmo10010RinvLineEntrynot-accessiblecurrentRow definition for the XFP table
1.3.6.1.4.1.20044.76.7.1.2.1.1Columnpmo10010RinvLineIndexread-onlycurrentIndex for XFP table
1.3.6.1.4.1.20044.76.7.1.2.1.2Columnpmo10010RinvxfpLineread-onlycurrentInventory for the XFP: This OID contains the inventory for the XFP
1.3.6.1.4.1.20044.76.7.2Scalarpmo10010RinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.76.7.3Scalarpmo10010RinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.76.7.4Scalarpmo10010RinvModulePlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.76.7.5Scalarpmo10010RinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.76.7.6Scalarpmo10010RinvGwPlatformread-onlycurrentGW platform desciption: This OID contains the description of the Gateware platform.
1.3.6.1.4.1.20044.76.8Nodepmo10010download
1.3.6.1.4.1.20044.76.8.1Nodepmo10010DwlOther
1.3.6.1.4.1.20044.76.8.1.0Nodepmo10010DwlrestartProcess
1.3.6.1.4.1.20044.76.8.1.0.1Scalarpmo10010DwlWarmRestartProcessedread-onlycurrentWarm Restart :This OID indicates that the module last restart was a Warm RESTART
1.3.6.1.4.1.20044.76.8.1.0.2Scalarpmo10010DwlColdRestartProcessedread-onlycurrentCold Restart :This OID indicates that the module last restart was a Cold RESTART
1.3.6.1.4.1.20044.76.8.1.1Nodepmo10010DwlswBanksUsed
1.3.6.1.4.1.20044.76.8.1.1.1Scalarpmo10010DwlSwBank1Usedread-onlycurrentSW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby
1.3.6.1.4.1.20044.76.8.1.1.2Scalarpmo10010DwlSwBank2Usedread-onlycurrentSW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby
1.3.6.1.4.1.20044.76.8.1.1.5Scalarpmo10010DwlSwBank1Notemptyread-onlycurrentSW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package
1.3.6.1.4.1.20044.76.8.1.1.6Scalarpmo10010DwlSwBank2Notemptyread-onlycurrentSW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package
1.3.6.1.4.1.20044.76.8.1.2Nodepmo10010DwlgwBanksUsed
1.3.6.1.4.1.20044.76.8.1.2.1Scalarpmo10010DwlGwBank1Usedread-onlycurrentGW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby
1.3.6.1.4.1.20044.76.8.1.2.2Scalarpmo10010DwlGwBank2Usedread-onlycurrentGW bank 2 active :This OID indicates the module is working on GW bank 2
1.3.6.1.4.1.20044.76.8.1.2.3Scalarpmo10010DwlGwBank3Usedread-onlycurrentGW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby
1.3.6.1.4.1.20044.76.8.1.2.4Scalarpmo10010DwlGwBank4Usedread-onlycurrentGW bank 4 active :This OID indicates the module is working on GW bank 4
1.3.6.1.4.1.20044.76.8.1.2.5Scalarpmo10010DwlGwBank1Notemptyread-onlycurrentGW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package
1.3.6.1.4.1.20044.76.8.1.2.6Scalarpmo10010DwlGwBank2Notemptyread-onlycurrentGW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2
1.3.6.1.4.1.20044.76.8.1.2.7Scalarpmo10010DwlGwBank3Notemptyread-onlycurrentGW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package
1.3.6.1.4.1.20044.76.8.1.2.8Scalarpmo10010DwlGwBank4Notemptyread-onlycurrentGW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4
1.3.6.1.4.1.20044.76.8.2Nodepmo10010DwlClient
1.3.6.1.4.1.20044.76.8.3Nodepmo10010DwlLine
1.3.6.1.4.1.20044.76.9Nodepmo10010Config
1.3.6.1.4.1.20044.76.9.1Nodepmo10010CfgAccessCAisCsf
1.3.6.1.4.1.20044.76.9.1.1Tablepmo10010CfgClientcaiscsfTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.76.9.1.1.1Rowpmo10010CfgClientcaiscsfEntrynot-accessiblecurrentRow definition for the accessCAisCsf table
1.3.6.1.4.1.20044.76.9.1.1.1.1Columnpmo10010CfgClientcaiscsfIndexread-onlycurrentIndex definition for the clientcaiscsf table
1.3.6.1.4.1.20044.76.9.1.1.1.3Columnpmo10010CfgReservePortnread-writecurrentCAIS mode on Client Port :This register enables/disables port laser shutdown on CAIS insertion condition
1.3.6.1.4.1.20044.76.9.2Nodepmo10010CfgStartup
1.3.6.1.4.1.20044.76.9.2.1Tablepmo10010CfgClientStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.76.9.2.1.1Rowpmo10010CfgClientStartupEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.76.9.2.1.1.1Columnpmo10010CfgClientStartupIndexread-onlycurrentIndex definition for the clientStartup table
1.3.6.1.4.1.20044.76.9.2.1.1.3Columnpmo10010CfgSystConfPortPortnread-writecurrentDefault Settings on Client Port :This register configures the default initialisation settings on the port.
1.3.6.1.4.1.20044.76.9.2.1.1.4Columnpmo10010CfgNetConfPortPortnread-writecurrentDefault Settings on Client Port :This register configures the default initialisation settings on the port.
1.3.6.1.4.1.20044.76.9.2.1.1.14Columnpmo10010CfgOptionsPortPortnread-writecurrentDefault Options on Client Port :This register configures the default options on the port.
1.3.6.1.4.1.20044.76.9.2.2Tablepmo10010CfgLineStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.76.9.2.2.1Rowpmo10010CfgLineStartupEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.76.9.2.2.1.1Columnpmo10010CfgLineStartupIndexread-onlycurrentIndex definition for the lineStartup table
1.3.6.1.4.1.20044.76.9.2.2.1.3Columnpmo10010CfgSystConfLinePortnread-writecurrentDefault Settings on Line :This register configures the default initialisation settings on Line
1.3.6.1.4.1.20044.76.9.2.2.1.14Columnpmo10010CfgOptionsLinePortnread-writecurrentDefault Options on Line :This register configures the default options on the line
1.3.6.1.4.1.20044.76.9.2.3Tablepmo10010CfgXfpTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.76.9.2.3.1Rowpmo10010CfgXfpEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.76.9.2.3.1.1Columnpmo10010CfgXfpIndexread-onlycurrentIndex definition for the xfp table
1.3.6.1.4.1.20044.76.9.2.3.1.3Columnpmo10010CfgSystConfMsaLinePortnread-writecurrentDefault settings on MSA :This register configures the default initialisation settings on MSA
1.3.6.1.4.1.20044.76.9.2.4Tablepmo10010CfgClientOtxtlhTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.76.9.2.4.1Rowpmo10010CfgClientOtxtlhEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.76.9.2.4.1.1Columnpmo10010CfgClientOtxtlhIndexread-onlycurrentIndex definition for the clientOtxtlh table
1.3.6.1.4.1.20044.76.9.2.4.1.3Columnpmo10010CfgControlsPortnread-writedeprecatedDefaut Client settings :This register configures the start-up settings on the ports
1.3.6.1.4.1.20044.76.9.2.4.1.6Columnpmo10010CfgClientPwrLaserPortnread-writecurrentDefaut Client output Power :This register configures the start-up output power of the client transceiver (Unit = dBm)
1.3.6.1.4.1.20044.76.9.2.4.1.7Columnpmo10010CfgClientFCurrentPortnread-writecurrentDefault Client transceiver Channel :This register configures the start-up laser channel of the client transceiver
1.3.6.1.4.1.20044.76.9.2.4.1.8Columnpmo10010CfgClientGridCurrentPortnread-writecurrentDefault Client transceiver Grid :This register configures the start-up laser grid of the client transceiver
1.3.6.1.4.1.20044.76.9.2.4.1.9Columnpmo10010CfgClientFoPortnread-writecurrentDefault Client first Frequency :This register configures the start-up first frequency of the client transceiver
1.3.6.1.4.1.20044.76.9.3Nodepmo10010CfgLabels
1.3.6.1.4.1.20044.76.9.3.1Tablepmo10010CfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.76.9.3.1.1Rowpmo10010CfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.76.9.3.1.1.1Columnpmo10010CfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.76.9.3.1.1.3Columnpmo10010CfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.76.9.3.2Tablepmo10010CfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.76.9.3.2.1Rowpmo10010CfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.76.9.3.2.1.1Columnpmo10010CfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.76.9.3.2.1.3Columnpmo10010CfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.76.9.4Nodepmo10010CfgStartuptlh
1.3.6.1.4.1.20044.76.9.4.1Tablepmo10010CfgOtxtlhTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.76.9.4.1.1Rowpmo10010CfgOtxtlhEntrynot-accessiblecurrentRow definition for the startuptlh table
1.3.6.1.4.1.20044.76.9.4.1.1.1Columnpmo10010CfgOtxtlhIndexread-onlycurrentIndex definition for the otxtlh table
1.3.6.1.4.1.20044.76.9.4.1.1.6Columnpmo10010CfgLinePwrLaserPortnread-writecurrentDefaut Line output Power :This register configures the start-up output power of the Line tranceiver (Unit = dBm)
1.3.6.1.4.1.20044.76.9.4.1.1.7Columnpmo10010CfgLineFCurrentPortnread-writecurrentDefault Line transceiver Tx Channel :This register configures the start-up laser channel of the Line Tx transceiver
1.3.6.1.4.1.20044.76.9.4.1.1.8Columnpmo10010CfgLineGridCurrentPortnread-writecurrentDefault Line transceiver Grid :This register configures the start-up laser grid of the Line transceiver
1.3.6.1.4.1.20044.76.9.4.1.1.9Columnpmo10010CfgFPortnread-writecurrentDefault Line TRX lowest Freq :This register configures the start-up lowest frequency of the Line transceiver
1.3.6.1.4.1.20044.76.9.4.1.1.10Columnpmo10010CfgRxLineFCurrentPortnread-writecurrentDefault Line transceiver Rx Channel :This register configures the start-up laser channel of the Line Rx transceiver
1.3.6.1.4.1.20044.76.9.5Nodepmo10010CfgOther
1.3.6.1.4.1.20044.76.9.5.1Nodepmo10010tablemoduleOther
1.3.6.1.4.1.20044.76.9.5.1.2Scalarpmo10010Cfgmoderead-writecurrentDefault settings on Module :This register selects the configuration mode of the module
1.3.6.1.4.1.20044.76.9.5.1.3Scalarpmo10010CfgfanLowSpeedThresholdread-writecurrentDefault settings on Module :This register selects the speed threshold of the fan's
1.3.6.1.4.1.20044.76.9.5.1.4Scalarpmo10010CfgfanHighSpeedThresholdread-writecurrentDefault settings on Module :This register selects the speed threshold of the fan's
1.3.6.1.4.1.20044.76.9.6Nodepmo10010CfgOdu2Clienta
1.3.6.1.4.1.20044.76.9.6.1Tablepmo10010CfgClientStartupOduTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.76.9.6.1.1Rowpmo10010CfgClientStartupOduEntrynot-accessiblecurrentRow definition for the odu2Clienta table
1.3.6.1.4.1.20044.76.9.6.1.1.1Columnpmo10010CfgClientStartupOduIndexread-onlycurrentIndex definition for the clientStartupOdu table
1.3.6.1.4.1.20044.76.9.6.1.1.3Columnpmo10010CfgOdu2ReserveLsbPortnread-writecurrent:
1.3.6.1.4.1.20044.76.9.6.1.1.4Columnpmo10010CfgOdu2DegthresholdMsbPortnread-writecurrentODU2 Degrade Threshold :
1.3.6.1.4.1.20044.76.9.6.1.1.5Columnpmo10010CfgOdu2DegmPortnread-writecurrentODU2 Degrade Confirmation :
1.3.6.1.4.1.20044.76.9.6.1.1.6Columnpmo10010CfgOdu2SettingsPortnread-writecurrentODU2 Settings :
1.3.6.1.4.1.20044.76.9.7Nodepmo10010CfgOtu4Line
1.3.6.1.4.1.20044.76.9.7.1Tablepmo10010CfgLinexStartupOtuTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.76.9.7.1.1Rowpmo10010CfgLinexStartupOtuEntrynot-accessiblecurrentRow definition for the otu4Line table
1.3.6.1.4.1.20044.76.9.7.1.1.1Columnpmo10010CfgLinexStartupOtuIndexread-onlycurrentIndex definition for the linexStartupOtu table
1.3.6.1.4.1.20044.76.9.7.1.1.3Columnpmo10010CfgOtu4ReserveLsbPortnread-writecurrent:
1.3.6.1.4.1.20044.76.9.7.1.1.4Columnpmo10010CfgOtu4DegthresholdMsbPortnread-writecurrentOTU4 Degrade Threshold :
1.3.6.1.4.1.20044.76.9.7.1.1.5Columnpmo10010CfgOtu4DegmPortnread-writecurrentOTU4 Degrade Confirmation :
1.3.6.1.4.1.20044.76.9.7.1.1.6Columnpmo10010CfgOtu4SettingsPortnread-writecurrentOTU4 Settings :
1.3.6.1.4.1.20044.76.9.8Nodepmo10010CfgOdu4Line
1.3.6.1.4.1.20044.76.9.8.1Tablepmo10010CfgLinexStartupOduTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.76.9.8.1.1Rowpmo10010CfgLinexStartupOduEntrynot-accessiblecurrentRow definition for the odu4Line table
1.3.6.1.4.1.20044.76.9.8.1.1.1Columnpmo10010CfgLinexStartupOduIndexread-onlycurrentIndex definition for the linexStartupOdu table
1.3.6.1.4.1.20044.76.9.8.1.1.3Columnpmo10010CfgOdu4ReserveLsbPortnread-writecurrent:
1.3.6.1.4.1.20044.76.9.8.1.1.4Columnpmo10010CfgOdu4DegthresholdMsbPortnread-writecurrentODU4 Degrade Threshold :
1.3.6.1.4.1.20044.76.9.8.1.1.5Columnpmo10010CfgOdu4DegmPortnread-writecurrentODU4 Degrade Confirmation :
1.3.6.1.4.1.20044.76.9.8.1.1.6Columnpmo10010CfgOdu4SettingsPortnread-writecurrentODU4 Settings :
1.3.6.1.4.1.20044.76.9.9Nodepmo10010CfgSapiTxClient
1.3.6.1.4.1.20044.76.9.9.1Tablepmo10010CfgClientSapiTxOduTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.76.9.9.1.1Rowpmo10010CfgClientSapiTxOduEntrynot-accessiblecurrentRow definition for the sapiTxClient table
1.3.6.1.4.1.20044.76.9.9.1.1.1Columnpmo10010CfgClientSapiTxOduIndexread-onlycurrentIndex definition for the clientSapiTxOdu table
1.3.6.1.4.1.20044.76.9.9.1.1.3Columnpmo10010CfgClientSapiTxSetupPortnread-writecurrentClient Transmitted SAPI :This register defines the value of the transmitted Trace Identifier on the line output
1.3.6.1.4.1.20044.76.9.10Nodepmo10010CfgSapiExpClient
1.3.6.1.4.1.20044.76.9.10.1Tablepmo10010CfgClientSapiExpOduTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.76.9.10.1.1Rowpmo10010CfgClientSapiExpOduEntrynot-accessiblecurrentRow definition for the sapiExpClient table
1.3.6.1.4.1.20044.76.9.10.1.1.1Columnpmo10010CfgClientSapiExpOduIndexread-onlycurrentIndex definition for the clientSapiExpOdu table
1.3.6.1.4.1.20044.76.9.10.1.1.3Columnpmo10010CfgClientSapiExpSetupPortnread-writecurrentClient Expected SAPI :This register defines the value of the expected Trace Identifier on the line input
1.3.6.1.4.1.20044.76.9.11Nodepmo10010CfgSapiAccClient
1.3.6.1.4.1.20044.76.9.11.1Tablepmo10010CfgClientSapiAccOduTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.76.9.11.1.1Rowpmo10010CfgClientSapiAccOduEntrynot-accessiblecurrentRow definition for the sapiAccClient table
1.3.6.1.4.1.20044.76.9.11.1.1.1Columnpmo10010CfgClientSapiAccOduIndexread-onlycurrentIndex definition for the clientSapiAccOdu table
1.3.6.1.4.1.20044.76.9.11.1.1.3Columnpmo10010CfgClientSapiAccSetupPortnread-writedeprecatedClient Accepted SAPI :This register defines the value of the accepted Trace Identifier on the line input
1.3.6.1.4.1.20044.76.9.12Nodepmo10010CfgDapiTxClient
1.3.6.1.4.1.20044.76.9.12.1Tablepmo10010CfgClientDapiTxOduTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.76.9.12.1.1Rowpmo10010CfgClientDapiTxOduEntrynot-accessiblecurrentRow definition for the dapiTxClient table
1.3.6.1.4.1.20044.76.9.12.1.1.1Columnpmo10010CfgClientDapiTxOduIndexread-onlycurrentIndex definition for the clientDapiTxOdu table
1.3.6.1.4.1.20044.76.9.12.1.1.3Columnpmo10010CfgClientDapiTxSetupPortnread-writecurrentClient Transmitted DAPI :This register defines the value of the transmitted Trace Identifier on the line output
1.3.6.1.4.1.20044.76.9.13Nodepmo10010CfgDapiExpClient
1.3.6.1.4.1.20044.76.9.13.1Tablepmo10010CfgClientDapiExpOduTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.76.9.13.1.1Rowpmo10010CfgClientDapiExpOduEntrynot-accessiblecurrentRow definition for the dapiExpClient table
1.3.6.1.4.1.20044.76.9.13.1.1.1Columnpmo10010CfgClientDapiExpOduIndexread-onlycurrentIndex definition for the clientDapiExpOdu table
1.3.6.1.4.1.20044.76.9.13.1.1.3Columnpmo10010CfgClientDapiExpSetupPortnread-writecurrentClient Expected DAPI :This register defines the value of the expected Trace Identifier on the line input
1.3.6.1.4.1.20044.76.9.14Nodepmo10010CfgDapiAccClient
1.3.6.1.4.1.20044.76.9.14.1Tablepmo10010CfgClientDapiAccOduTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.76.9.14.1.1Rowpmo10010CfgClientDapiAccOduEntrynot-accessiblecurrentRow definition for the dapiAccClient table
1.3.6.1.4.1.20044.76.9.14.1.1.1Columnpmo10010CfgClientDapiAccOduIndexread-onlycurrentIndex definition for the clientDapiAccOdu table
1.3.6.1.4.1.20044.76.9.14.1.1.3Columnpmo10010CfgClientDapiAccSetupPortnread-writedeprecatedClient Accepted DAPI :This register defines the value of the accepted Trace Identifier on the line input
1.3.6.1.4.1.20044.76.9.15Nodepmo10010CfgSapiTxLineOtu4
1.3.6.1.4.1.20044.76.9.15.1Tablepmo10010CfgLineSapiTxOtuTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.76.9.15.1.1Rowpmo10010CfgLineSapiTxOtuEntrynot-accessiblecurrentRow definition for the sapiTxLineOtu4 table
1.3.6.1.4.1.20044.76.9.15.1.1.1Columnpmo10010CfgLineSapiTxOtuIndexread-onlycurrentIndex definition for the lineSapiTxOtu table
1.3.6.1.4.1.20044.76.9.15.1.1.3Columnpmo10010CfgLineSapiTxSetupOtuPortnread-writecurrentOTU4 Line Transmitted SAPI :This register defines the value of the transmitted Trace Identifier on the line output
1.3.6.1.4.1.20044.76.9.16Nodepmo10010CfgSapiExpLineOtu4
1.3.6.1.4.1.20044.76.9.16.1Tablepmo10010CfgLineSapiExpOtuTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.76.9.16.1.1Rowpmo10010CfgLineSapiExpOtuEntrynot-accessiblecurrentRow definition for the sapiExpLineOtu4 table
1.3.6.1.4.1.20044.76.9.16.1.1.1Columnpmo10010CfgLineSapiExpOtuIndexread-onlycurrentIndex definition for the lineSapiExpOtu table
1.3.6.1.4.1.20044.76.9.16.1.1.3Columnpmo10010CfgLineSapiExpSetupOtuPortnread-writecurrentOTU4 Line Expected SAPI :This register defines the value of the expected Trace Identifier on the line input
1.3.6.1.4.1.20044.76.9.17Nodepmo10010CfgSapiAccLineOtu4
1.3.6.1.4.1.20044.76.9.17.1Tablepmo10010CfgLineSapiAccOtuTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.76.9.17.1.1Rowpmo10010CfgLineSapiAccOtuEntrynot-accessiblecurrentRow definition for the sapiAccLineOtu4 table
1.3.6.1.4.1.20044.76.9.17.1.1.1Columnpmo10010CfgLineSapiAccOtuIndexread-onlycurrentIndex definition for the lineSapiAccOtu table
1.3.6.1.4.1.20044.76.9.17.1.1.3Columnpmo10010CfgLineSapiAccSetupOtuPortnread-writedeprecatedOTU4 Line Accepted SAPI :This register defines the value of the accepted Trace Identifier on the line input
1.3.6.1.4.1.20044.76.9.18Nodepmo10010CfgDapiTxLineOtu4
1.3.6.1.4.1.20044.76.9.18.1Tablepmo10010CfgLineDapiTxOtuTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.76.9.18.1.1Rowpmo10010CfgLineDapiTxOtuEntrynot-accessiblecurrentRow definition for the dapiTxLineOtu4 table
1.3.6.1.4.1.20044.76.9.18.1.1.1Columnpmo10010CfgLineDapiTxOtuIndexread-onlycurrentIndex definition for the lineDapiTxOtu table
1.3.6.1.4.1.20044.76.9.18.1.1.3Columnpmo10010CfgLineDapiTxSetupOtuPortnread-writecurrentOTU4 Line Transmitted DAPI :This register defines the value of the transmitted Trace Identifier on the line output
1.3.6.1.4.1.20044.76.9.19Nodepmo10010CfgDapiExpLineOtu4
1.3.6.1.4.1.20044.76.9.19.1Tablepmo10010CfgLineDapiExpOtuTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.76.9.19.1.1Rowpmo10010CfgLineDapiExpOtuEntrynot-accessiblecurrentRow definition for the dapiExpLineOtu4 table
1.3.6.1.4.1.20044.76.9.19.1.1.1Columnpmo10010CfgLineDapiExpOtuIndexread-onlycurrentIndex definition for the lineDapiExpOtu table
1.3.6.1.4.1.20044.76.9.19.1.1.3Columnpmo10010CfgLineDapiExpSetupOtuPortnread-writecurrentOTU4 Line Expected DAPI :This register defines the value of the expected Trace Identifier on the line input
1.3.6.1.4.1.20044.76.9.20Nodepmo10010CfgDapiAccLineOtu4
1.3.6.1.4.1.20044.76.9.20.1Tablepmo10010CfgLineDapiAccOtuTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.76.9.20.1.1Rowpmo10010CfgLineDapiAccOtuEntrynot-accessiblecurrentRow definition for the dapiAccLineOtu4 table
1.3.6.1.4.1.20044.76.9.20.1.1.1Columnpmo10010CfgLineDapiAccOtuIndexread-onlycurrentIndex definition for the lineDapiAccOtu table
1.3.6.1.4.1.20044.76.9.20.1.1.3Columnpmo10010CfgLineDapiAccSetupOtuPortnread-writedeprecatedOTU4 Line Accepted DAPI :This register defines the value of the accepted Trace Identifier on the line input
1.3.6.1.4.1.20044.76.9.21Nodepmo10010CfgSapiTxLineOdu4
1.3.6.1.4.1.20044.76.9.21.1Tablepmo10010CfgLineSapiTxOduTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.76.9.21.1.1Rowpmo10010CfgLineSapiTxOduEntrynot-accessiblecurrentRow definition for the sapiTxLineOdu4 table
1.3.6.1.4.1.20044.76.9.21.1.1.1Columnpmo10010CfgLineSapiTxOduIndexread-onlycurrentIndex definition for the lineSapiTxOdu table
1.3.6.1.4.1.20044.76.9.21.1.1.3Columnpmo10010CfgLineSapiTxSetupOduPortnread-writecurrentODU4 Line Transmitted SAPI :This register defines the value of the transmitted Trace Identifier on the line output
1.3.6.1.4.1.20044.76.9.22Nodepmo10010CfgSapiExpLineOdu4
1.3.6.1.4.1.20044.76.9.22.1Tablepmo10010CfgLineSapiExpOduTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.76.9.22.1.1Rowpmo10010CfgLineSapiExpOduEntrynot-accessiblecurrentRow definition for the sapiExpLineOdu4 table
1.3.6.1.4.1.20044.76.9.22.1.1.1Columnpmo10010CfgLineSapiExpOduIndexread-onlycurrentIndex definition for the lineSapiExpOdu table
1.3.6.1.4.1.20044.76.9.22.1.1.3Columnpmo10010CfgLineSapiExpSetupOduPortnread-writecurrentODU4 Line Expected SAPI :This register defines the value of the expected Trace Identifier on the line input
1.3.6.1.4.1.20044.76.9.23Nodepmo10010CfgSapiAccLineOdu4
1.3.6.1.4.1.20044.76.9.23.1Tablepmo10010CfgLineSapiAccOduTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.76.9.23.1.1Rowpmo10010CfgLineSapiAccOduEntrynot-accessiblecurrentRow definition for the sapiAccLineOdu4 table
1.3.6.1.4.1.20044.76.9.23.1.1.1Columnpmo10010CfgLineSapiAccOduIndexread-onlycurrentIndex definition for the lineSapiAccOdu table
1.3.6.1.4.1.20044.76.9.23.1.1.3Columnpmo10010CfgLineSapiAccSetupOduPortnread-writedeprecatedODU4 Line Accepted SAPI :This register defines the value of the accepted Trace Identifier on the line input
1.3.6.1.4.1.20044.76.9.24Nodepmo10010CfgDapiTxLineOdu4
1.3.6.1.4.1.20044.76.9.24.1Tablepmo10010CfgLineDapiTxOduTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.76.9.24.1.1Rowpmo10010CfgLineDapiTxOduEntrynot-accessiblecurrentRow definition for the dapiTxLineOdu4 table
1.3.6.1.4.1.20044.76.9.24.1.1.1Columnpmo10010CfgLineDapiTxOduIndexread-onlycurrentIndex definition for the lineDapiTxOdu table
1.3.6.1.4.1.20044.76.9.24.1.1.3Columnpmo10010CfgLineDapiTxSetupOduPortnread-writecurrentODU4 Line Transmitted DAPI :This register defines the value of the transmitted Trace Identifier on the line output
1.3.6.1.4.1.20044.76.9.25Nodepmo10010CfgDapiExpLineOdu4
1.3.6.1.4.1.20044.76.9.25.1Tablepmo10010CfgLineDapiExpOduTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.76.9.25.1.1Rowpmo10010CfgLineDapiExpOduEntrynot-accessiblecurrentRow definition for the dapiExpLineOdu4 table
1.3.6.1.4.1.20044.76.9.25.1.1.1Columnpmo10010CfgLineDapiExpOduIndexread-onlycurrentIndex definition for the lineDapiExpOdu table
1.3.6.1.4.1.20044.76.9.25.1.1.3Columnpmo10010CfgLineDapiExpSetupOduPortnread-writecurrentODU4 Line Expected DAPI :This register defines the value of the expected Trace Identifier on the line input
1.3.6.1.4.1.20044.76.9.26Nodepmo10010CfgDapiAccLineOdu4
1.3.6.1.4.1.20044.76.9.26.1Tablepmo10010CfgLineDapiAccOduTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.76.9.26.1.1Rowpmo10010CfgLineDapiAccOduEntrynot-accessiblecurrentRow definition for the dapiAccLineOdu4 table
1.3.6.1.4.1.20044.76.9.26.1.1.1Columnpmo10010CfgLineDapiAccOduIndexread-onlycurrentIndex definition for the lineDapiAccOdu table
1.3.6.1.4.1.20044.76.9.26.1.1.3Columnpmo10010CfgLineDapiAccSetupOduPortnread-writedeprecatedODU4 Line Accepted DAPI :This register defines the value of the accepted Trace Identifier on the line input
1.3.6.1.4.1.20044.76.9.27Nodepmo10010CfgStartuptablefive
1.3.6.1.4.1.20044.76.9.27.1Tablepmo10010CfgOtxtlhcapabilitiesTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.76.9.27.1.1Rowpmo10010CfgOtxtlhcapabilitiesEntrynot-accessiblecurrentRow definition for the startuptablefive table
1.3.6.1.4.1.20044.76.9.27.1.1.1Columnpmo10010CfgOtxtlhcapabilitiesIndexread-onlycurrentIndex definition for the otxtlhcapabilities table
1.3.6.1.4.1.20044.76.9.27.1.1.3Columnpmo10010CfgComponentTypePortnread-onlycurrentComponent parameters :This OID defines the component parameters
1.3.6.1.4.1.20044.76.9.27.1.1.4Columnpmo10010CfgMiscellaneousPortnread-onlycurrentMiscellaneous default settings :This OID defines the miscellaneous parameters
1.3.6.1.4.1.20044.76.9.27.1.1.5Columnpmo10010CfgFirstChannelPortnread-onlycurrentNumber of the first channel of the component :This OID defines the first channel number of the PM
1.3.6.1.4.1.20044.76.9.27.1.1.6Columnpmo10010CfgLastChannelPortnread-onlycurrentNumber of the last channel of the component :This OID defines the last channel number of the PM
1.3.6.1.4.1.20044.76.9.27.1.1.7Columnpmo10010CfgGridPortnread-onlycurrentGrid value of the component :This OID defines the grid of the PM
1.3.6.1.4.1.20044.76.9.257Scalarpmo10010CfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.76.10Nodepmo10010traps
1.3.6.1.4.1.20044.76.10.2Scalarpmo10010trapPortNumberread-onlycurrentLast port which generates a trap
1.3.6.1.4.1.20044.76.10.3Scalarpmo10010trapLineNumberread-onlycurrentLast Line which generates a trap
1.3.6.1.4.1.20044.76.10.4Scalarpmo10010trapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.76.10.30Notificationpmo10010LineTrapNotUrgentGoesOncurrentNot urgent Line default is activated
1.3.6.1.4.1.20044.76.10.31Notificationpmo10010LineTrapNotUrgentGoesOffcurrentNot urgent Line default disappeared
1.3.6.1.4.1.20044.76.10.32Notificationpmo10010LineTrapUrgentGoesOncurrentUrgent Line default is activated
1.3.6.1.4.1.20044.76.10.33Notificationpmo10010LineTrapUrgentGoesOffcurrentUrgent Line default disappeared
1.3.6.1.4.1.20044.76.10.34Notificationpmo10010LineTrapCritGoesOncurrentCritical Line default is activated
1.3.6.1.4.1.20044.76.10.35Notificationpmo10010LineTrapCritGoesOffcurrentCritical Line default disappeared
1.3.6.1.4.1.20044.76.10.40Notificationpmo10010ClientTrapNotUrgentGoesOncurrentNot urgent client default is activated
1.3.6.1.4.1.20044.76.10.41Notificationpmo10010ClientTrapNotUrgentGoesOffcurrentNot urgent client default disappeared
1.3.6.1.4.1.20044.76.10.42Notificationpmo10010ClientTrapUrgentGoesOncurrentUrgent client default is activated
1.3.6.1.4.1.20044.76.10.43Notificationpmo10010ClientTrapUrgentGoesOffcurrentUrgent client default disappeared
1.3.6.1.4.1.20044.76.10.44Notificationpmo10010ClientTrapCritGoesOncurrentCritical client default is activated
1.3.6.1.4.1.20044.76.10.45Notificationpmo10010ClientTrapCritGoesOffcurrentCritical client default disappeared
1.3.6.1.4.1.20044.76.10.50Notificationpmo10010PowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.76.10.51Notificationpmo10010PowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared
1.3.6.1.4.1.20044.76.11Nodepmo10010Monitoring
1.3.6.1.4.1.20044.76.11.1Nodepmo10010MonOther
1.3.6.1.4.1.20044.76.11.1.3Nodepmo10010MonRmon
1.3.6.1.4.1.20044.76.11.2Nodepmo10010MonClient
1.3.6.1.4.1.20044.76.11.2.4Nodepmo10010MonClientRmonCounter
1.3.6.1.4.1.20044.76.11.2.4.16Tablepmo10010MonupRmonBytesCounterClientInputTablenot-accessiblecurrentList of pmo10010MonupRmonBytesCounterClientInput Article
1.3.6.1.4.1.20044.76.11.2.4.16.1Rowpmo10010MonupRmonBytesCounterClientInputEntrynot-accessiblecurrentRow definition for the pmo10010MonupRmonBytesCounterClientInput table
1.3.6.1.4.1.20044.76.11.2.4.16.1.1Columnpmo10010MonupRmonBytesCounterClientInputIndexread-onlycurrentIndex definition for the pmo10010MonupRmonBytesCounterClientInput table
1.3.6.1.4.1.20044.76.11.2.4.16.1.2Columnpmo10010MonupRmonBytesCounterClientInputValuePortnread-onlycurrentClient Input Bytes :This counter is increased each time a data byte is received on the client port <Help> This counter gives the number of bytes received on th…
1.3.6.1.4.1.20044.76.11.2.4.16.1.3Columnpmo10010MonupRmonBytesCounterClientInputErrorPortnread-onlycurrentBytes Counter Error :This OID when set indicates the Bytes counter value is invalid on client port
1.3.6.1.4.1.20044.76.11.2.4.16.1.4Columnpmo10010MonupRmonBytesCounterClientInputOverloadPortnread-onlycurrentBytes Counter Overload :This OID when set indicates a Bytes counter overload on client port
1.3.6.1.4.1.20044.76.11.2.4.32Tablepmo10010MonupRmonFcsErrorsCounterClientInputTablenot-accessiblecurrentList of pmo10010MonupRmonFcsErrorsCounterClientInput Article
1.3.6.1.4.1.20044.76.11.2.4.32.1Rowpmo10010MonupRmonFcsErrorsCounterClientInputEntrynot-accessiblecurrentRow definition for the pmo10010MonupRmonFcsErrorsCounterClientInput table
1.3.6.1.4.1.20044.76.11.2.4.32.1.1Columnpmo10010MonupRmonFcsErrorsCounterClientInputIndexread-onlycurrentIndex definition for the pmo10010MonupRmonFcsErrorsCounterClientInput table
1.3.6.1.4.1.20044.76.11.2.4.32.1.2Columnpmo10010MonupRmonFcsErrorsCounterClientInputValuePortnread-onlycurrentClient Input FCS Errors :This counter is increased each time a FCS error is detected on the client port <Help> This counter gives the number of FCS Errors rece…
1.3.6.1.4.1.20044.76.11.2.4.32.1.3Columnpmo10010MonupRmonFcsErrorsCounterClientInputErrorPortnread-onlycurrentFCS Errors Counter Error :This OID when set indicates the FCS Errors counter value is invalid on client port
1.3.6.1.4.1.20044.76.11.2.4.32.1.4Columnpmo10010MonupRmonFcsErrorsCounterClientInputOverloadPortnread-onlycurrentFCS Errors Counter Overload :This OID when set indicates a FCS Errors counter overload on client port
1.3.6.1.4.1.20044.76.11.2.4.48Tablepmo10010MonupRmonPacketsCounterClientInputTablenot-accessiblecurrentList of pmo10010MonupRmonPacketsCounterClientInput Article
1.3.6.1.4.1.20044.76.11.2.4.48.1Rowpmo10010MonupRmonPacketsCounterClientInputEntrynot-accessiblecurrentRow definition for the pmo10010MonupRmonPacketsCounterClientInput table
1.3.6.1.4.1.20044.76.11.2.4.48.1.1Columnpmo10010MonupRmonPacketsCounterClientInputIndexread-onlycurrentIndex definition for the pmo10010MonupRmonPacketsCounterClientInput table
1.3.6.1.4.1.20044.76.11.2.4.48.1.2Columnpmo10010MonupRmonPacketsCounterClientInputValuePortnread-onlycurrentClient Input Packets :This counter is increased each time a packet is received on the client port <Help> This counter gives the number of packets received on t…
1.3.6.1.4.1.20044.76.11.2.4.48.1.3Columnpmo10010MonupRmonPacketsCounterClientInputErrorPortnread-onlycurrentPackets Counter Error :This OID when set indicates the Packets counter value is invalid on client port
1.3.6.1.4.1.20044.76.11.2.4.48.1.4Columnpmo10010MonupRmonPacketsCounterClientInputOverloadPortnread-onlycurrentPackets Counter Overload :This OID when set indicates a Packets counter overload on client port
1.3.6.1.4.1.20044.76.11.2.4.64Tablepmo10010MonupRmonBroadcastCounterClientInputTablenot-accessiblecurrentList of pmo10010MonupRmonBroadcastCounterClientInput Article
1.3.6.1.4.1.20044.76.11.2.4.64.1Rowpmo10010MonupRmonBroadcastCounterClientInputEntrynot-accessiblecurrentRow definition for the pmo10010MonupRmonBroadcastCounterClientInput table
1.3.6.1.4.1.20044.76.11.2.4.64.1.1Columnpmo10010MonupRmonBroadcastCounterClientInputIndexread-onlycurrentIndex definition for the pmo10010MonupRmonBroadcastCounterClientInput table
1.3.6.1.4.1.20044.76.11.2.4.64.1.2Columnpmo10010MonupRmonBroadcastCounterClientInputValuePortnread-onlycurrentClient Input Broadcast Packets :This counter is increased each time a broadcast packet is received on the client port <Help> This counter gives the number of B…
1.3.6.1.4.1.20044.76.11.2.4.64.1.3Columnpmo10010MonupRmonBroadcastCounterClientInputErrorPortnread-onlycurrentBroadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on client port
1.3.6.1.4.1.20044.76.11.2.4.64.1.4Columnpmo10010MonupRmonBroadcastCounterClientInputOverloadPortnread-onlycurrentBroadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port
1.3.6.1.4.1.20044.76.11.2.4.80Tablepmo10010MonupRmonMulticastCounterClientInputTablenot-accessiblecurrentList of pmo10010MonupRmonMulticastCounterClientInput Article
1.3.6.1.4.1.20044.76.11.2.4.80.1Rowpmo10010MonupRmonMulticastCounterClientInputEntrynot-accessiblecurrentRow definition for the pmo10010MonupRmonMulticastCounterClientInput table
1.3.6.1.4.1.20044.76.11.2.4.80.1.1Columnpmo10010MonupRmonMulticastCounterClientInputIndexread-onlycurrentIndex definition for the pmo10010MonupRmonMulticastCounterClientInput table
1.3.6.1.4.1.20044.76.11.2.4.80.1.2Columnpmo10010MonupRmonMulticastCounterClientInputValuePortnread-onlycurrentClient Input Multicast Packets :This counter is increased each time a Multicast packet is received on the client port <Help> This counter gives the number of M…
1.3.6.1.4.1.20044.76.11.2.4.80.1.3Columnpmo10010MonupRmonMulticastCounterClientInputErrorPortnread-onlycurrentMulticast Counter Error :This OID when set indicates the Multicast counter value is invalid on client port
1.3.6.1.4.1.20044.76.11.2.4.80.1.4Columnpmo10010MonupRmonMulticastCounterClientInputOverloadPortnread-onlycurrentMulticast Counter Overload :This OID when set indicates a Multicast counter overload on client port
1.3.6.1.4.1.20044.76.11.2.4.96Tablepmo10010MonupRmonPauseFrameCounterClientInputTablenot-accessiblecurrentList of pmo10010MonupRmonPauseFrameCounterClientInput Article
1.3.6.1.4.1.20044.76.11.2.4.96.1Rowpmo10010MonupRmonPauseFrameCounterClientInputEntrynot-accessiblecurrentRow definition for the pmo10010MonupRmonPauseFrameCounterClientInput table
1.3.6.1.4.1.20044.76.11.2.4.96.1.1Columnpmo10010MonupRmonPauseFrameCounterClientInputIndexread-onlycurrentIndex definition for the pmo10010MonupRmonPauseFrameCounterClientInput table
1.3.6.1.4.1.20044.76.11.2.4.96.1.2Columnpmo10010MonupRmonPauseFrameCounterClientInputValuePortnread-onlycurrentClient Input Pause Frames :This counter is increased each time a Pause frame is received on the client port <Help> This counter gives the number of Pause frame…
1.3.6.1.4.1.20044.76.11.2.4.96.1.3Columnpmo10010MonupRmonPauseFrameCounterClientInputErrorPortnread-onlycurrentPause Counter Error :This OID when set indicates the Pause counter value is invalid on client port
1.3.6.1.4.1.20044.76.11.2.4.96.1.4Columnpmo10010MonupRmonPauseFrameCounterClientInputOverloadPortnread-onlycurrentPause Counter Overload :This OID when set indicates a Pause counter overload on client port
1.3.6.1.4.1.20044.76.11.2.4.160Tablepmo10010MonupRmonUnicastCounterClientInputTablenot-accessiblecurrentList of pmo10010MonupRmonUnicastCounterClientInput Article
1.3.6.1.4.1.20044.76.11.2.4.160.1Rowpmo10010MonupRmonUnicastCounterClientInputEntrynot-accessiblecurrentRow definition for the pmo10010MonupRmonUnicastCounterClientInput table
1.3.6.1.4.1.20044.76.11.2.4.160.1.1Columnpmo10010MonupRmonUnicastCounterClientInputIndexread-onlycurrentIndex definition for the pmo10010MonupRmonUnicastCounterClientInput table
1.3.6.1.4.1.20044.76.11.2.4.160.1.2Columnpmo10010MonupRmonUnicastCounterClientInputValuePortnread-onlycurrentClient Input Unicast Packets :This counter is increased each time a Unicast packet is received on the client port <Help> This counter gives the number of Unica…
1.3.6.1.4.1.20044.76.11.2.4.160.1.3Columnpmo10010MonupRmonUnicastCounterClientInputErrorPortnread-onlycurrentUnicast Counter Error :This OID when set indicates the Unicast counter value is invalid on client port
1.3.6.1.4.1.20044.76.11.2.4.160.1.4Columnpmo10010MonupRmonUnicastCounterClientInputOverloadPortnread-onlycurrentUnicast Counter Overload :This OID when set indicates a Unicast counter overload on client port
1.3.6.1.4.1.20044.76.11.2.4.176Tablepmo10010MonupRmonNonunicastCounterClientInputTablenot-accessiblecurrentList of pmo10010MonupRmonNonunicastCounterClientInput Article
1.3.6.1.4.1.20044.76.11.2.4.176.1Rowpmo10010MonupRmonNonunicastCounterClientInputEntrynot-accessiblecurrentRow definition for the pmo10010MonupRmonNonunicastCounterClientInput table
1.3.6.1.4.1.20044.76.11.2.4.176.1.1Columnpmo10010MonupRmonNonunicastCounterClientInputIndexread-onlycurrentIndex definition for the pmo10010MonupRmonNonunicastCounterClientInput table
1.3.6.1.4.1.20044.76.11.2.4.176.1.2Columnpmo10010MonupRmonNonunicastCounterClientInputValuePortnread-onlycurrentClient Input Non Unicast Packets :This counter is increased each time a Non-Unicast packet is received on the client port <Help> This counter gives the number …
1.3.6.1.4.1.20044.76.11.2.4.176.1.3Columnpmo10010MonupRmonNonunicastCounterClientInputErrorPortnread-onlycurrentNon Unicast Counter Error :This OID when set indicates the Non-Unicast counter value is invalid on client port
1.3.6.1.4.1.20044.76.11.2.4.176.1.4Columnpmo10010MonupRmonNonunicastCounterClientInputOverloadPortnread-onlycurrentNon Unicast Counter Overload :This OID when set indicates a Non-Unicast counter overload on client port
1.3.6.1.4.1.20044.76.11.2.4.208Tablepmo10010MondownRmonBytesCounterClientOutputTablenot-accessiblecurrentList of pmo10010MondownRmonBytesCounterClientOutput Article
1.3.6.1.4.1.20044.76.11.2.4.208.1Rowpmo10010MondownRmonBytesCounterClientOutputEntrynot-accessiblecurrentRow definition for the pmo10010MondownRmonBytesCounterClientOutput table
1.3.6.1.4.1.20044.76.11.2.4.208.1.1Columnpmo10010MondownRmonBytesCounterClientOutputIndexread-onlycurrentIndex definition for the pmo10010MondownRmonBytesCounterClientOutput table
1.3.6.1.4.1.20044.76.11.2.4.208.1.2Columnpmo10010MondownRmonBytesCounterClientOutputValuePortnread-onlycurrentClient Output Bytes :This counter is increased each time a data byte is transmitted on the client port <Help> This counter gives the number of bytes transmitte…
1.3.6.1.4.1.20044.76.11.2.4.208.1.3Columnpmo10010MondownRmonBytesCounterClientOutputErrorPortnread-onlycurrentBytes Counter Error :This OID when set indicates the Bytes counter value is invalid on client port
1.3.6.1.4.1.20044.76.11.2.4.208.1.4Columnpmo10010MondownRmonBytesCounterClientOutputOverloadPortnread-onlycurrentBytes Counter Overload :This OID when set indicates a Bytes counter overload on client port
1.3.6.1.4.1.20044.76.11.2.4.224Tablepmo10010MondownRmonFcsErrorsCounterClientOutputTablenot-accessiblecurrentList of pmo10010MondownRmonFcsErrorsCounterClientOutput Article
1.3.6.1.4.1.20044.76.11.2.4.224.1Rowpmo10010MondownRmonFcsErrorsCounterClientOutputEntrynot-accessiblecurrentRow definition for the pmo10010MondownRmonFcsErrorsCounterClientOutput table
1.3.6.1.4.1.20044.76.11.2.4.224.1.1Columnpmo10010MondownRmonFcsErrorsCounterClientOutputIndexread-onlycurrentIndex definition for the pmo10010MondownRmonFcsErrorsCounterClientOutput table
1.3.6.1.4.1.20044.76.11.2.4.224.1.2Columnpmo10010MondownRmonFcsErrorsCounterClientOutputValuePortnread-onlycurrentClient Output FCS Errors :This counter is increased each time a FCS error is detected on the transmit client port <Help> This counter gives the number of FCS E…
1.3.6.1.4.1.20044.76.11.2.4.224.1.3Columnpmo10010MondownRmonFcsErrorsCounterClientOutputErrorPortnread-onlycurrentFCS Errors Counter Error :This OID when set indicates the FCS Errors counter value is invalid on client port
1.3.6.1.4.1.20044.76.11.2.4.224.1.4Columnpmo10010MondownRmonFcsErrorsCounterClientOutputOverloadPortnread-onlycurrentFCS Errors Counter Overload :This OID when set indicates a FCS Errors counter overload on client port
1.3.6.1.4.1.20044.76.11.2.4.240Tablepmo10010MondownRmonPacketsCounterClientOutputTablenot-accessiblecurrentList of pmo10010MondownRmonPacketsCounterClientOutput Article
1.3.6.1.4.1.20044.76.11.2.4.240.1Rowpmo10010MondownRmonPacketsCounterClientOutputEntrynot-accessiblecurrentRow definition for the pmo10010MondownRmonPacketsCounterClientOutput table
1.3.6.1.4.1.20044.76.11.2.4.240.1.1Columnpmo10010MondownRmonPacketsCounterClientOutputIndexread-onlycurrentIndex definition for the pmo10010MondownRmonPacketsCounterClientOutput table
1.3.6.1.4.1.20044.76.11.2.4.240.1.2Columnpmo10010MondownRmonPacketsCounterClientOutputValuePortnread-onlycurrentClient Output Packets :This counter is increased each time a packet is transmitted on the client port <Help> This counter gives the number of packets transmitt…
1.3.6.1.4.1.20044.76.11.2.4.240.1.3Columnpmo10010MondownRmonPacketsCounterClientOutputErrorPortnread-onlycurrentPackets Counter Error :This OID when set indicates the Packets counter value is invalid on client port
1.3.6.1.4.1.20044.76.11.2.4.240.1.4Columnpmo10010MondownRmonPacketsCounterClientOutputOverloadPortnread-onlycurrentPackets Counter Overload :This OID when set indicates a Packets counter overload on client port
1.3.6.1.4.1.20044.76.11.2.4.256Tablepmo10010MondownRmonBroadcastCounterClientOutputTablenot-accessiblecurrentList of pmo10010MondownRmonBroadcastCounterClientOutput Article
1.3.6.1.4.1.20044.76.11.2.4.256.1Rowpmo10010MondownRmonBroadcastCounterClientOutputEntrynot-accessiblecurrentRow definition for the pmo10010MondownRmonBroadcastCounterClientOutput table
1.3.6.1.4.1.20044.76.11.2.4.256.1.1Columnpmo10010MondownRmonBroadcastCounterClientOutputIndexread-onlycurrentIndex definition for the pmo10010MondownRmonBroadcastCounterClientOutput table
1.3.6.1.4.1.20044.76.11.2.4.256.1.2Columnpmo10010MondownRmonBroadcastCounterClientOutputValuePortnread-onlycurrentClient Output Broadcast Packets :This counter is increased each time a broadcast packet is transmitted on the client port <Help> This counter gives the number …
1.3.6.1.4.1.20044.76.11.2.4.256.1.3Columnpmo10010MondownRmonBroadcastCounterClientOutputErrorPortnread-onlycurrentBroadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on client port
1.3.6.1.4.1.20044.76.11.2.4.256.1.4Columnpmo10010MondownRmonBroadcastCounterClientOutputOverloadPortnread-onlycurrentBroadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port
1.3.6.1.4.1.20044.76.11.2.4.272Tablepmo10010MondownRmonMulticastCounterClientOutputTablenot-accessiblecurrentList of pmo10010MondownRmonMulticastCounterClientOutput Article
1.3.6.1.4.1.20044.76.11.2.4.272.1Rowpmo10010MondownRmonMulticastCounterClientOutputEntrynot-accessiblecurrentRow definition for the pmo10010MondownRmonMulticastCounterClientOutput table
1.3.6.1.4.1.20044.76.11.2.4.272.1.1Columnpmo10010MondownRmonMulticastCounterClientOutputIndexread-onlycurrentIndex definition for the pmo10010MondownRmonMulticastCounterClientOutput table
1.3.6.1.4.1.20044.76.11.2.4.272.1.2Columnpmo10010MondownRmonMulticastCounterClientOutputValuePortnread-onlycurrentClient Output Multicast Packets :This counter is increased each time a Multicast packet is transmitted on the client port <Help> This counter gives the number …
1.3.6.1.4.1.20044.76.11.2.4.272.1.3Columnpmo10010MondownRmonMulticastCounterClientOutputErrorPortnread-onlycurrentMulticast Counter Error :This OID when set indicates the Multicast counter value is invalid on client port
1.3.6.1.4.1.20044.76.11.2.4.272.1.4Columnpmo10010MondownRmonMulticastCounterClientOutputOverloadPortnread-onlycurrentMulticast Counter Overload :This OID when set indicates a Multicast counter overload on client port
1.3.6.1.4.1.20044.76.11.2.4.288Tablepmo10010MondownRmonPauseFrameCounterClientOutputTablenot-accessiblecurrentList of pmo10010MondownRmonPauseFrameCounterClientOutput Article
1.3.6.1.4.1.20044.76.11.2.4.288.1Rowpmo10010MondownRmonPauseFrameCounterClientOutputEntrynot-accessiblecurrentRow definition for the pmo10010MondownRmonPauseFrameCounterClientOutput table
1.3.6.1.4.1.20044.76.11.2.4.288.1.1Columnpmo10010MondownRmonPauseFrameCounterClientOutputIndexread-onlycurrentIndex definition for the pmo10010MondownRmonPauseFrameCounterClientOutput table
1.3.6.1.4.1.20044.76.11.2.4.288.1.2Columnpmo10010MondownRmonPauseFrameCounterClientOutputValuePortnread-onlycurrentClient Output Pause Frames :This counter is increased each time a Pause frame is transmitted on the client port <Help> This counter gives the number of Pause f…
1.3.6.1.4.1.20044.76.11.2.4.288.1.3Columnpmo10010MondownRmonPauseFrameCounterClientOutputErrorPortnread-onlycurrentPause Counter Error :This OID when set indicates the Pause counter value is invalid on client port
1.3.6.1.4.1.20044.76.11.2.4.288.1.4Columnpmo10010MondownRmonPauseFrameCounterClientOutputOverloadPortnread-onlycurrentPause Counter Overload :This OID when set indicates a Pause counter overload on client port
1.3.6.1.4.1.20044.76.11.2.4.352Tablepmo10010MondownRmonUnicastCounterClientOutputTablenot-accessiblecurrentList of pmo10010MondownRmonUnicastCounterClientOutput Article
1.3.6.1.4.1.20044.76.11.2.4.352.1Rowpmo10010MondownRmonUnicastCounterClientOutputEntrynot-accessiblecurrentRow definition for the pmo10010MondownRmonUnicastCounterClientOutput table
1.3.6.1.4.1.20044.76.11.2.4.352.1.1Columnpmo10010MondownRmonUnicastCounterClientOutputIndexread-onlycurrentIndex definition for the pmo10010MondownRmonUnicastCounterClientOutput table
1.3.6.1.4.1.20044.76.11.2.4.352.1.2Columnpmo10010MondownRmonUnicastCounterClientOutputValuePortnread-onlycurrentClient Output Unicast Packets :This counter is increased each time a Unicast packet is transmitted on the client port <Help> This counter gives the number of U…
1.3.6.1.4.1.20044.76.11.2.4.352.1.3Columnpmo10010MondownRmonUnicastCounterClientOutputErrorPortnread-onlycurrentUnicast Counter Error :This OID when set indicates the Unicast counter value is invalid on client port
1.3.6.1.4.1.20044.76.11.2.4.352.1.4Columnpmo10010MondownRmonUnicastCounterClientOutputOverloadPortnread-onlycurrentUnicast Counter Overload :This OID when set indicates a Unicast counter overload on client port
1.3.6.1.4.1.20044.76.11.2.4.368Tablepmo10010MondownRmonNonunicastCounterClientOutputTablenot-accessiblecurrentList of pmo10010MondownRmonNonunicastCounterClientOutput Article
1.3.6.1.4.1.20044.76.11.2.4.368.1Rowpmo10010MondownRmonNonunicastCounterClientOutputEntrynot-accessiblecurrentRow definition for the pmo10010MondownRmonNonunicastCounterClientOutput table
1.3.6.1.4.1.20044.76.11.2.4.368.1.1Columnpmo10010MondownRmonNonunicastCounterClientOutputIndexread-onlycurrentIndex definition for the pmo10010MondownRmonNonunicastCounterClientOutput table
1.3.6.1.4.1.20044.76.11.2.4.368.1.2Columnpmo10010MondownRmonNonunicastCounterClientOutputValuePortnread-onlycurrentClient Output Non Unicast Packets :This counter is increased each time a Non-Unicast packet is transmitted on the client port <Help> This counter gives the num…
1.3.6.1.4.1.20044.76.11.2.4.368.1.3Columnpmo10010MondownRmonNonunicastCounterClientOutputErrorPortnread-onlycurrentNon Unicast Counter Error :This OID when set indicates the Non-Unicast counter value is invalid on client port
1.3.6.1.4.1.20044.76.11.2.4.368.1.4Columnpmo10010MondownRmonNonunicastCounterClientOutputOverloadPortnread-onlycurrentNon Unicast Counter Overload :This OID when set indicates a Non-Unicast counter overload on client port
Type Definitions
NameSyntaxStatusDescription
Pmo10010AdjustValueINTEGER { otxadjustvalue0(0), otxadjustvalue1(1), otxadjustvalue2(2), otxadjustvalue3(3), otxadjustvalue4(4), otxadjustvalue5(5), otxadjustvalue6(6), otxadjustvalue7(7), otxadjustvalue8(8), otxadjustvalue9(9), otxadjustvalue10(10) }currentDifferent values in Adjust mode on OTX-TLH on client and line ports
Pmo10010ClientProtocolINTEGER { protocolclientvalue0(0), protocolclientvalue1(1), protocolclientvalue2(2), protocolclientvalue3(3), protocolclientvalue4(4), protocolclientvalue5(5), protocolclientvalue6(6), protocolclientvalue7(7), protocolclientvalue8(8) }currentDifferent values on the protocol on the client ports
Pmo10010MultiRateINTEGER { rate100Mhz(0), rate250Mhz(1), rate500Mhz(2), rate1Ghz(3) }currentdifferent rate for a client port
Pmo10010Odu2SapiModeINTEGER { off(0), sapi(1) dapi(2) sapidapi(3), }currentMode for SAPI-DAPI
Pmo10010OrxChannelINTEGERcurrentChannel selection on transceiver Rx line ports
Pmo10010Otu4SapiModeINTEGER { off(0), sapi(1) dapi(2) sapidapi(3), }currentMode for SAPI-DAPI
Pmo10010OtxChannelINTEGERcurrentChannel selection on transceiver Tx line ports
Pmo10010OtxGridINTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50) }currentDifferent grids on OTX-TLH on client and line ports
Pmo10010OtxModeINTEGER { otx80mode(1), otx60mode(2), otxadjustmode(4) }currentDifferent modes on OTX-TLH on client and line ports
Pmo10010ProtocolModeINTEGER { protocolmodevalue0(0), protocolmodevalue1(1), protocolmodevalue2(2), protocolmodevalue3(3) }currentDifferent values on the protocol mode