EKINOPS-Pmo10010-MIB
933 objects
Creation.
Imported Objects
| EKINOPS-MIB | EkiApiState EkiMeasureType EkiMode ekinops EkiOnOff EkiProtocol EkiState EkiSynchroMode |
| SNMPv2-SMI | Counter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20044.76 | IdentitymodulePmo10010 | Creation. | ||
| 1.3.6.1.4.1.20044.76.2 | Nodepmo10010alarms | |||
| 1.3.6.1.4.1.20044.76.2.1 | Nodepmo10010AlmOther | |||
| 1.3.6.1.4.1.20044.76.2.1.1 | Nodepmo10010AlmOtherNurg | |||
| 1.3.6.1.4.1.20044.76.2.1.1.2 | Nodepmo10010AlmsynthAlm2 | |||
| 1.3.6.1.4.1.20044.76.2.1.1.2.1 | Scalarpmo10010AlmConfTableSave | read-only | current | PM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> infor… |
| 1.3.6.1.4.1.20044.76.2.1.1.2.2 | Scalarpmo10010AlmInvUpload | read-only | current | Inventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> informationalStatus(1000) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.76.2.1.1.2.3 | Scalarpmo10010AlmConfTableLoad | read-only | current | PM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> informationalStat… |
| 1.3.6.1.4.1.20044.76.2.1.1.2.4 | Scalarpmo10010AlmCorrelatOff | read-only | current | Not Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> informationalStatus(1000) <Alarmtype… |
| 1.3.6.1.4.1.20044.76.2.1.1.2.5 | Scalarpmo10010AlmMaintenanceOn | read-only | current | Maintenance Mode :This OID indicates that the RM is in maintenance mode. <Help> This alarm indicates that the maintenance mode is enabled on the PM <Condtype> … |
| 1.3.6.1.4.1.20044.76.2.1.2 | Nodepmo10010AlmOtherUrg | |||
| 1.3.6.1.4.1.20044.76.2.1.3 | Nodepmo10010AlmOtherCrit | |||
| 1.3.6.1.4.1.20044.76.2.1.3.0 | Nodepmo10010AlmsynthAlm0 | |||
| 1.3.6.1.4.1.20044.76.2.1.3.0.2 | Scalarpmo10010AlmFailFan | read-only | current | Fan Fail :This OID is at 1 when any fail occurs on the fan tray <Help> This alarm indicates that the Fan tray module is in a failure condition <Condtype> FAIL_… |
| 1.3.6.1.4.1.20044.76.2.1.3.0.9 | Scalarpmo10010AlmModGlobFail | read-only | current | Module Failure :This OID is set on detection of a failure originating from the RM <Help> This alarm is set on detection of a failure originating from the equip… |
| 1.3.6.1.4.1.20044.76.2.1.3.0.15 | Scalarpmo10010AlmDefFuseA | read-only | current | Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.76.2.1.3.0.16 | Scalarpmo10010AlmDefFuseB | read-only | current | Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.76.2.1.3.40 | Nodepmo10010AlmclientModuleState | |||
| 1.3.6.1.4.1.20044.76.2.1.3.40.1 | Scalarpmo10010AlmCfpInitialize | read-only | current | Client Trscv Initialize :This OID indicates the Client Trscv initialization is in progress <Help> Status indicating the Client Trscv initialization is in progr… |
| 1.3.6.1.4.1.20044.76.2.1.3.40.2 | Scalarpmo10010AlmCfpLowPower | read-only | current | Client Trscv Low Power :This OID indicates the Client Trscv is in low power state <Help> Status indicating the Client Trscv is in low power state <Condtype> CF… |
| 1.3.6.1.4.1.20044.76.2.1.3.40.3 | Scalarpmo10010AlmCfpHighPowerUp | read-only | current | Client Trscv High Power Up :This OID indicates the Client Trscv is leaving Low Power state <Help> Status indicating the Client Trscv is leaving Low Power state… |
| 1.3.6.1.4.1.20044.76.2.1.3.40.4 | Scalarpmo10010AlmCfpTxOff | read-only | current | Client Trscv Laser Shutdown :This OID indicates the Client Trscv Laser is OFF <Help> Status indicating the Client Trscv Laser is OFF <Condtype> CFP_TX_OFF <Pro… |
| 1.3.6.1.4.1.20044.76.2.1.3.40.5 | Scalarpmo10010AlmCfpTxTurnOn | read-only | current | Client Trscv Laser Turn On :This OID indicates the Client Trscv is turning on its laser <Help> Status indicating the Client Trscv is turning on its laser <Cond… |
| 1.3.6.1.4.1.20044.76.2.1.3.40.6 | Scalarpmo10010AlmCfpReady | read-only | current | Client Trscv Ready :This OID indicates the Client Trscv is ready to operate <Help> Status indicating the Client Trscv is ready to operate <Condtype> CFP_READY … |
| 1.3.6.1.4.1.20044.76.2.1.3.40.7 | Scalarpmo10010AlmCfpFault | read-only | current | Client Trscv Fault :This OID indicates the Client Trscv is in Fault state <Help> Status indicating the Client Trscv is in Fault state <Condtype> CFP_FAULT <Pro… |
| 1.3.6.1.4.1.20044.76.2.1.3.40.8 | Scalarpmo10010AlmCfpTxTurnOff | read-only | current | Client Trscv Laser Turn Off :This OID indicates the Client Trscv is turning off its laser <Help> Status indicating the Client Trscv is turning off its laser <C… |
| 1.3.6.1.4.1.20044.76.2.1.3.40.9 | Scalarpmo10010AlmCfpHighPowerDown | read-only | current | Client Trscv High Power Down :This OID indicates the Client Trscv is entering Low Power state <Help> Status indicating the Client Trscv is entering Low Power s… |
| 1.3.6.1.4.1.20044.76.2.1.3.41 | Nodepmo10010AlmclientModuleGeneralStatus | |||
| 1.3.6.1.4.1.20044.76.2.1.3.41.4 | Scalarpmo10010AlmCfpOutOfAlignment | read-only | current | Client Trscv Out Of Alignment :This OID indicates an Out of alignment on the Client Trscv Host Interface <Help> Alarm indicating an Out of alignment on the Cli… |
| 1.3.6.1.4.1.20044.76.2.1.3.41.5 | Scalarpmo10010AlmCfpRxNetworkLol | read-only | current | Client Trscv Rx Network Loss Of Lock :This OID indicates of Loss of Lock is dected on the Client Trscv Rx Network interface <Help> Alarm indicating of Loss of … |
| 1.3.6.1.4.1.20044.76.2.1.3.41.6 | Scalarpmo10010AlmCfpRxLos | read-only | current | Client Trscv Loss Of Signal :This OID indicates a Loss of Signal is detected on the Client Trscv <Help> Alarm indicating a Loss of Signal is detected on the Cl… |
| 1.3.6.1.4.1.20044.76.2.1.3.41.7 | Scalarpmo10010AlmCfpTxHostLol | read-only | current | Client Trscv Tx Host Loss Of Lock :This OID indicates of Loss of Lock is detected on the Client Trscv Tx Host interface <Help> Alarm indicating of Loss of Lock… |
| 1.3.6.1.4.1.20044.76.2.1.3.41.8 | Scalarpmo10010AlmCfpTxLosf | read-only | current | Client Trscv Loss Of Signal Functionality :This OID indicates a Loss of Signal functionality is detected on the Client Trscv <Help> Alarm indicating a Loss of … |
| 1.3.6.1.4.1.20044.76.2.1.3.41.9 | Scalarpmo10010AlmCfpTxCmuLol | read-only | current | Client Trscv CMU Loss Of Lock :This OID indicates a Clock Multiplier Unit Loss of Lock is detected on the Client Trscv <Help> Alarm indicating a Clock Multipli… |
| 1.3.6.1.4.1.20044.76.2.1.3.41.10 | Scalarpmo10010AlmCfpTxJitterPllLol | read-only | current | Client Trscv Tx Jitter PLL Loss Of Lock :This OID indicates a Tx Jitter PLL Loss of Lock is dtected on the Client Trscv <Help> Alarm indicating a Tx Jitter PLL… |
| 1.3.6.1.4.1.20044.76.2.1.3.41.11 | Scalarpmo10010AlmCfpLossOfRefclk | read-only | current | Client Trscv Loss Of Ref Clock :This OID indicates a Loss of Reference clock is detected on the Client Trscv <Help> Alarm indicating a Loss of Reference clock … |
| 1.3.6.1.4.1.20044.76.2.1.3.41.14 | Scalarpmo10010AlmCfpHwInterlock | read-only | current | Client Trscv Hardware Interlock :This OID indicates the Client Trscv power is higher than the cooling capacity <Help> Alarm indicating the Client Trscv power i… |
| 1.3.6.1.4.1.20044.76.2.1.3.42 | Nodepmo10010AlmclientGlobalAlarmSummary | |||
| 1.3.6.1.4.1.20044.76.2.1.3.42.1 | Scalarpmo10010AlmCfpSoftGlobAlarmTest | read-only | current | Client Trscv Global Alarm SW Test :This OID indicates the Client Trscv Global Alarm This OID is raised by SW request for test purpose <Help> Status indicating … |
| 1.3.6.1.4.1.20044.76.2.1.3.42.7 | Scalarpmo10010AlmCfpNetworkLaneAlarmWarning2 | read-only | current | Client Trscv Network Alarm And Warning 2 :This OID indicates at least one DDM is detected on the Client Trscv Network Interface <Help> Synthesis alarm indicati… |
| 1.3.6.1.4.1.20044.76.2.1.3.42.8 | Scalarpmo10010AlmCfpModuleState | read-only | current | Client Trscv Module State :This OID indicates the Client Trscv module state <Help> Synthesis alarm indicating the Client Trscv module state <Condtype> CFP_MODU… |
| 1.3.6.1.4.1.20044.76.2.1.3.42.9 | Scalarpmo10010AlmCfpModuleGeneralStatus | read-only | current | Client Trscv General Status :This OID indicates the Client Trscv module general status <Help> Synthesis alarm indicating the Client Trscv module general status… |
| 1.3.6.1.4.1.20044.76.2.1.3.42.10 | Scalarpmo10010AlmCfpModuleFault | read-only | current | Client Trscv Module Fault :This OID indicates at least one Fault is detected on the Client Trscv module <Help> Synthesis alarm indicating at least one Fault is… |
| 1.3.6.1.4.1.20044.76.2.1.3.42.11 | Scalarpmo10010AlmCfpModuleAlarmWarning1 | read-only | current | Client Trscv Module Alarm And Warning 1 :This OID indicates at least one DDM This OID is detected on the Client Trscv module <Help> Synthesis alarm indicating … |
| 1.3.6.1.4.1.20044.76.2.1.3.42.12 | Scalarpmo10010AlmCfpModuleAlarmWarning2 | read-only | current | Client Trscv Module Alarm And Warning 2 :This OID indicates at least one DDM is detected on the Client Trscv module <Help> Synthesis alarm indicating at least … |
| 1.3.6.1.4.1.20044.76.2.1.3.42.13 | Scalarpmo10010AlmCfpNetworkLaneAlarmWarning1 | read-only | current | Client Trscv Network Alarm And Warning 1 :This OID indicates at least one DDM is detected on the Client Trscv Network Interface <Help> Synthesis alarm indicati… |
| 1.3.6.1.4.1.20044.76.2.1.3.42.14 | Scalarpmo10010AlmCfpNetworkLaneFaultStatus | read-only | current | Client Trscv Network Fault And Status :This OID indicates at least one Fault or Status is detected on the Client Trscv Network Interface <Help> Synthesis alarm… |
| 1.3.6.1.4.1.20044.76.2.1.3.42.15 | Scalarpmo10010AlmCfpHostLaneFaultStatus | read-only | current | Client Trscv Host Fault And Status :This OID indicates at least one Fault or Status is detected on the Client Trscv Host Interface <Help> Synthesis alarm indic… |
| 1.3.6.1.4.1.20044.76.2.1.3.42.16 | Scalarpmo10010AlmCfpGlobAlarmAssertion | read-only | current | Client Trscv Global Alarm :This OID indicates at least one Fault or Status is detected on the Client Trscv module <Help> Synthesis alarm indicating at least on… |
| 1.3.6.1.4.1.20044.76.2.1.3.46 | Nodepmo10010AlmmsaModuleState | |||
| 1.3.6.1.4.1.20044.76.2.1.3.46.1 | Scalarpmo10010AlmMsaInitialize | read-only | current | Line Trscv Initialize :This OID indicates the Line Trscv initialization is in progress <Help> Status indicating the Line Trscv initialization is in progress <C… |
| 1.3.6.1.4.1.20044.76.2.1.3.46.2 | Scalarpmo10010AlmMsaLowPower | read-only | current | Line Trscv Low Power :This OID indicates the Line Trscv is in low power state <Help> Status indicating the Line Trscv is in low power state <Condtype> MSA_LOW_… |
| 1.3.6.1.4.1.20044.76.2.1.3.46.3 | Scalarpmo10010AlmMsaHighPowerUp | read-only | current | Line Trscv High Power Up :This OID indicates the Line Trscv is leaving Low Power state <Help> Status indicating the Line Trscv is leaving Low Power state <Cond… |
| 1.3.6.1.4.1.20044.76.2.1.3.46.4 | Scalarpmo10010AlmMsaTxOff | read-only | current | Line Trscv Laser Shutdown :This OID indicates the Line Trscv Laser is OFF <Help> Status indicating the Line Trscv Laser is OFF <Condtype> MSA_TX_OFF <Probcause… |
| 1.3.6.1.4.1.20044.76.2.1.3.46.5 | Scalarpmo10010AlmMsaTxTurnOn | read-only | current | Line Trscv Laser Turn On :This OID indicates the Line Trscv is turning on its laser <Help> Status indicating the Line Trscv is turning on its laser <Condtype> … |
| 1.3.6.1.4.1.20044.76.2.1.3.46.6 | Scalarpmo10010AlmMsaReady | read-only | current | Line Trscv Ready :This OID indicates the Line Trscv is ready to operate <Help> Status indicating the Line Trscv is ready to operate <Condtype> MSA_READY <Probc… |
| 1.3.6.1.4.1.20044.76.2.1.3.46.7 | Scalarpmo10010AlmMsaFault | read-only | current | Line Trscv Fault :This OID indicates the Line Trscv is in Fault state <Help> Status indicating the Line Trscv is in Fault state <Condtype> MSA_FAULT <Probcause… |
| 1.3.6.1.4.1.20044.76.2.1.3.46.8 | Scalarpmo10010AlmMsaTxTurnOff | read-only | current | Line Trscv Laser Turn Off :This OID indicates the Line Trscv is turning off its laser <Help> Status indicating the Line Trscv is turning off its laser <Condtyp… |
| 1.3.6.1.4.1.20044.76.2.1.3.46.9 | Scalarpmo10010AlmMsaHighPowerDown | read-only | current | Line Trscv High Power Down :This OID indicates the Line Trscv is entering Low Power state <Help> Status indicating the Line Trscv is entering Low Power state <… |
| 1.3.6.1.4.1.20044.76.2.1.3.47 | Nodepmo10010AlmmsaModuleGeneralStatus | |||
| 1.3.6.1.4.1.20044.76.2.1.3.47.4 | Scalarpmo10010AlmMsaOutOfAlignment | read-only | current | Line Trscv Out Of Alignment :This OID indicates an Out of alignment on the Line Trscv Host Interface <Help> Alarm indicating an Out of alignment on the Line Tr… |
| 1.3.6.1.4.1.20044.76.2.1.3.47.5 | Scalarpmo10010AlmMsaRxNetworkLol | read-only | current | Line Trscv Rx Network Loss Of Lock :This OID indicates of Loss of Lock is detected on the Line Trscv Rx Network interface <Help> Alarm indicating of Loss of Lo… |
| 1.3.6.1.4.1.20044.76.2.1.3.47.6 | Scalarpmo10010AlmMsaRxLos | read-only | current | Line Trscv Loss Of Signal :This OID indicates a Loss of Signal is detected on the Line Trscv <Help> Alarm indicating a Loss of Signal is detected on the Line T… |
| 1.3.6.1.4.1.20044.76.2.1.3.47.7 | Scalarpmo10010AlmMsaTxHostLol | read-only | current | Line Trscv Tx Host Loss Of Lock :This OID indicates of Loss of Lock is detected on the Line Trscv Tx Host interface <Help> Alarm indicating of Loss of Lock is … |
| 1.3.6.1.4.1.20044.76.2.1.3.47.8 | Scalarpmo10010AlmMsaTxLosf | read-only | current | Line Trscv Loss Of Signal Functionality :This OID indicates a Loss of Signal functionality is detected on the Line Trscv <Help> Alarm indicating a Loss of Sign… |
| 1.3.6.1.4.1.20044.76.2.1.3.47.9 | Scalarpmo10010AlmMsaTxCmuLol | read-only | current | Line Trscv CMU Loss Of Lock :This OID indicates a Clock Multiplier Unit Loss of Lock is detected on the Line Trscv <Help> Alarm indicating a Clock Multiplier U… |
| 1.3.6.1.4.1.20044.76.2.1.3.47.10 | Scalarpmo10010AlmMsaTxJitterPllLol | read-only | current | Line Trscv Tx Jitter PLL Loss Of Lock :This OID indicates a Tx Jitter PLL Loss of Lock is detected on the Line Trscv <Help> Alarm indicating a Tx Jitter PLL Lo… |
| 1.3.6.1.4.1.20044.76.2.1.3.47.11 | Scalarpmo10010AlmMsaLossOfRefclk | read-only | current | Line Trscv Loss Of Ref Clock :This OID indicates a Loss of Reference clock is detected on the Line Trscv <Help> Alarm indicating a Loss of Reference clock is d… |
| 1.3.6.1.4.1.20044.76.2.1.3.47.14 | Scalarpmo10010AlmMsaHwInterlock | read-only | current | Line Trscv Hardware Interlock :This OID indicates the Line Trscv power is higher than the cooling capacity <Help> Alarm indicating the Line Trscv power is high… |
| 1.3.6.1.4.1.20044.76.2.1.3.48 | Nodepmo10010AlmmsaGlobalAlarmSummary | |||
| 1.3.6.1.4.1.20044.76.2.1.3.48.1 | Scalarpmo10010AlmMsaSoftGlobAlarmTest | read-only | current | Line Trscv Global Alarm SW Test :This OID indicates the Line Trscv Global alarm This OID is raised by SW request for test purpose <Help> Status indicating the … |
| 1.3.6.1.4.1.20044.76.2.1.3.48.6 | Scalarpmo10010AlmMsaNetworkHostAlarmStatus | read-only | current | Line Trscv Network/Host Alarm Status :This OID indicates the state of the Network and Host interface of the Line Trscv <Help> Synthesis alarm indicating the al… |
| 1.3.6.1.4.1.20044.76.2.1.3.48.7 | Scalarpmo10010AlmMsaNetworkLaneAlarmWarning2 | read-only | current | Line Trscv Network Alarm And Warning 2 :This OID indicates at least one DDM This OID is detected on the Line Trscv Network Interface <Help> Synthesis alarm ind… |
| 1.3.6.1.4.1.20044.76.2.1.3.48.8 | Scalarpmo10010AlmMsaModuleState | read-only | current | Line Trscv Module State :This OID indicates the Line Trscv module state <Help> Synthesis alarm indicating the Line Trscv module state <Condtype> MSA_MODULE_STA… |
| 1.3.6.1.4.1.20044.76.2.1.3.48.9 | Scalarpmo10010AlmMsaModuleGeneralStatus | read-only | current | Line Trscv General Status :This OID indicates the Line Trscv module general <Help> Synthesis alarm indicating the Line Trscv module general status <Condtype> M… |
| 1.3.6.1.4.1.20044.76.2.1.3.48.10 | Scalarpmo10010AlmModuleFault | read-only | current | Line Trscv Module Fault :This OID indicates at least one Fault is detected on the Line Trscv module <Help> Synthesis alarm indicating at least one Fault is det… |
| 1.3.6.1.4.1.20044.76.2.1.3.48.11 | Scalarpmo10010AlmMsaModuleAlarmWarning1 | read-only | current | Line Trscv Module Alarm And Warning 1 :This OID indicates at least one DDM is detected on the Line Trscv module <Help> Synthesis alarm indicating at least one … |
| 1.3.6.1.4.1.20044.76.2.1.3.48.12 | Scalarpmo10010AlmMsaModuleAlarmWarning2 | read-only | current | Line Trscv Module Alarm And Warning 2 :This OID indicates at least one DDM is detected on the Line Trscv module <Help> Synthesis alarm indicating at least one … |
| 1.3.6.1.4.1.20044.76.2.1.3.48.13 | Scalarpmo10010AlmMsaNetworkLaneAlarmWarning1 | read-only | current | Line Trscv Network Alarm And Warning 1 :This OID indicates at least one DDM is detected on the Line Trscv Network Interface <Help> Synthesis alarm indicating a… |
| 1.3.6.1.4.1.20044.76.2.1.3.48.14 | Scalarpmo10010AlmMsaNetworkLaneFaultStatus | read-only | current | Line Trscv Network Fault And Status :This OID indicates at least one Fault or Status is detected on the Line Trscv Network Interface <Help> Synthesis alarm ind… |
| 1.3.6.1.4.1.20044.76.2.1.3.48.15 | Scalarpmo10010AlmMsaHostLaneFaultStatus | read-only | current | Line Trscv Host Fault And Status :This OID indicates at least one Fault or Status is detected on the Line Trscv Host Interface <Help> Synthesis alarm indicatin… |
| 1.3.6.1.4.1.20044.76.2.1.3.48.16 | Scalarpmo10010AlmMsaGlobAlarmAssertion | read-only | current | Line Trscv Global Alarm :This OID indicates at least one Fault or Status is detected on the Line Trscv module <Help> Synthesis alarm indicating at least one Al… |
| 1.3.6.1.4.1.20044.76.2.1.3.49 | Nodepmo10010AlmmsaNetworkTxAlignment | |||
| 1.3.6.1.4.1.20044.76.2.1.3.49.12 | Scalarpmo10010AlmNetTxTimingFault | read-only | current | Line Trscv Network Tx Timing Fault :This OID indicates a Tx Timing Fault is detected on the Line Trscv Network interface <Help> Alarm indicating a Tx Timing Fa… |
| 1.3.6.1.4.1.20044.76.2.1.3.49.13 | Scalarpmo10010AlmNetTxReferenceClockFault | read-only | current | Line Trscv Network Tx Ref Clock Fault :This OID indicates a Tx Reference Clock Fault is detected on the Line Trscv Network interface <Help> Alarm indicating a … |
| 1.3.6.1.4.1.20044.76.2.1.3.49.14 | Scalarpmo10010AlmNetTxCmuLockFault | read-only | current | Line Trscv Network Tx CMU Lock Fault :This OID indicates a Tx Clock Multiplier Unit Lock Fault is detected on the Line Trscv Network interface <Help> Alarm ind… |
| 1.3.6.1.4.1.20044.76.2.1.3.49.15 | Scalarpmo10010AlmNetTxOutOfAlignment | read-only | current | Line Trscv Network Tx Out Of Alignment :This OID indicates a Tx Out of Alignment is detected on the Line Trscv Network interface <Help> Alarm indicating a Tx O… |
| 1.3.6.1.4.1.20044.76.2.1.3.49.16 | Scalarpmo10010AlmNetTxLossOfAlignment | read-only | current | Line Trscv Network Tx Loss Of Alignment :This OID indicates a Tx Loss of Alignment is detected on the Line Trscv Network interface <Help> Alarm indicating a Tx… |
| 1.3.6.1.4.1.20044.76.2.1.3.50 | Nodepmo10010AlmmsaNetworkRxAlignment | |||
| 1.3.6.1.4.1.20044.76.2.1.3.50.12 | Scalarpmo10010AlmNetRxTimingFault | read-only | current | Line Trscv Network Rx Timing Fault :This OID indicates a Rx Timing Fault is detected on the Line Trscv Network interface <Help> Alarm indicating a Rx Timing Fa… |
| 1.3.6.1.4.1.20044.76.2.1.3.50.13 | Scalarpmo10010AlmNetRxOutOfAlignment | read-only | current | Line Trscv Network Rx Out Of Alignment :This OID indicates a Rx Out of Alignment is detected on the Line Trscv Network interface <Help> Alarm indicating a Rx O… |
| 1.3.6.1.4.1.20044.76.2.1.3.50.14 | Scalarpmo10010AlmNetRxLossOfAlignment | read-only | current | Line Trscv Network Rx Loss Of Alignment :This OID indicates a Rx Loss of Alignment is detected on the Line Trscv Network interface <Help> Alarm indicating a Rx… |
| 1.3.6.1.4.1.20044.76.2.1.3.50.15 | Scalarpmo10010AlmNetRxModemLockFault | read-only | current | Line Trscv Network Rx Modem Lock Fault :This OID indicates a Rx Modem Lock Fault is detected on the Line Trscv Network interface <Help> Alarm indicating a Rx M… |
| 1.3.6.1.4.1.20044.76.2.1.3.50.16 | Scalarpmo10010AlmNetRxModemSyncDetectFault | read-only | current | Line Trscv Network Rx Modem Sync Detect Fault :This OID indicates a Rx Modem Synchronisation Detection Fault is detected on the Line Trscv Network interface <H… |
| 1.3.6.1.4.1.20044.76.2.1.3.51 | Nodepmo10010AlmmsaNetworkHostNetworkAlarmSummary | |||
| 1.3.6.1.4.1.20044.76.2.1.3.51.11 | Scalarpmo10010AlmNetworkTxAlignment | read-only | current | Line Trscv Network Tx Alignment :This OID indicates a Tx Alignment Fault is detected on the Line Trscv Network interface <Help> Synthesis Alarm indicating a Tx… |
| 1.3.6.1.4.1.20044.76.2.1.3.51.12 | Scalarpmo10010AlmNetworkRxAlignment | read-only | current | Line Trscv Network Rx Alignment :This OID indicates a Rx Alignment Fault is detected on the Line Trscv Network interface <Help> Synthesis Alarm indicating a Rx… |
| 1.3.6.1.4.1.20044.76.2.1.3.51.13 | Scalarpmo10010AlmNetworkRxOtn | read-only | current | Line Trscv Network Rx OTN :This OID indicates a Rx OTN Fault is detected on the Line Trscv Network interface <Help> Synthesis Alarm indicating a Rx OTN Fault i… |
| 1.3.6.1.4.1.20044.76.2.1.3.51.14 | Scalarpmo10010AlmHostRxAlignment | read-only | current | Line Trscv Host Rx Alignment :This OID indicates a Rx Alignment Fault is detected on the Line Trscv Host interface <Help> Synthesis Alarm indicating a Rx Align… |
| 1.3.6.1.4.1.20044.76.2.1.3.51.15 | Scalarpmo10010AlmHostTxAlignment | read-only | current | Line Trscv Host Tx Alignment :This OID indicates a Tx Alignment Fault is detected on the Line Trscv Host interface <Help> Synthesis Alarm indicating a Tx Align… |
| 1.3.6.1.4.1.20044.76.2.1.3.51.16 | Scalarpmo10010AlmHostTxOtnStatus | read-only | current | Line Trscv Host Tx OTN :This OID indicates a Tx OTN Fault is detected on the Line Trscv Host interface <Help> Synthesis Alarm indicating a Tx OTN Fault is dete… |
| 1.3.6.1.4.1.20044.76.2.1.3.52 | Nodepmo10010AlmmsaHostTxAlignment | |||
| 1.3.6.1.4.1.20044.76.2.1.3.52.13 | Scalarpmo10010AlmHostTxDeskewLockFault | read-only | current | Line Trscv Host Tx Deskew Lock Fault :This OID indicates a Tx Deskew Lock Fault is detected on the Line Trscv Host interface <Help> Alarm indicating a Tx Deske… |
| 1.3.6.1.4.1.20044.76.2.1.3.52.14 | Scalarpmo10010AlmHostTxOutOfAlignment | read-only | current | Line Trscv Host Tx Out Of Alignment :This OID indicates a Tx Out of Alignment is detected on the Line Trscv Host interface <Help> Alarm indicating a Tx Out of … |
| 1.3.6.1.4.1.20044.76.2.1.3.52.15 | Scalarpmo10010AlmHostTxLossOfAlignment | read-only | current | Line Trscv Host Tx Loss Of Alignment :This OID indicates a Tx Loss of Alignment is detected on the Line Trscv Host interface <Help> Alarm indicating a Tx Loss … |
| 1.3.6.1.4.1.20044.76.2.1.3.52.16 | Scalarpmo10010AlmHostTxCdrLockFault | read-only | current | Line Trscv Host Tx CDR Lock Fault :This OID indicates a Tx Clock Data Recovery Lock Fault is detected on the Line Trscv Host interface <Help> Alarm indicating … |
| 1.3.6.1.4.1.20044.76.2.1.3.53 | Nodepmo10010AlmmsaHostRxAlignment | |||
| 1.3.6.1.4.1.20044.76.2.1.3.53.14 | Scalarpmo10010AlmHostRxCmuLockFault | read-only | current | Line Trscv Host Rx CMU Lock Fault :This OID indicates a Rx Clock Multiplier Unit Lock Fault is detected on the Line Trscv Host interface <Help> Alarm indicatin… |
| 1.3.6.1.4.1.20044.76.2.1.3.53.15 | Scalarpmo10010AlmHostRxOutOfAlignment | read-only | current | Line Trscv Host Rx Out Of Alignment :This OID indicates a Rx Out of Alignment is detected on the Line Trscv Host interface <Help> Alarm indicating a Rx Out of … |
| 1.3.6.1.4.1.20044.76.2.1.3.53.16 | Scalarpmo10010AlmHostRxLossOfAlignment | read-only | current | Line Trscv Host Rx Loss Of Alignment :This OID indicates a Rx Loss of Alignment is detected on the Line Trscv Host interface <Help> Alarm indicating a Rx Loss … |
| 1.3.6.1.4.1.20044.76.2.2 | Nodepmo10010AlmClient | |||
| 1.3.6.1.4.1.20044.76.2.2.1 | Nodepmo10010AlmClientNurg | |||
| 1.3.6.1.4.1.20044.76.2.2.1.56 | Tablepmo10010AlmclientNetworkLaneAlarmWarningTable | not-accessible | current | List of pmo10010AlmclientNetworkLaneAlarmWarning Article |
| 1.3.6.1.4.1.20044.76.2.2.1.56.1 | Rowpmo10010AlmclientNetworkLaneAlarmWarningEntry | not-accessible | current | Row definition for the pmo10010AlmclientNetworkLaneAlarmWarning table |
| 1.3.6.1.4.1.20044.76.2.2.1.56.1.1 | Columnpmo10010AlmclientNetworkLaneAlarmWarningIndex | read-only | current | Index definition for the pmo10010AlmclientNetworkLaneAlarmWarning table |
| 1.3.6.1.4.1.20044.76.2.2.1.56.1.2 | Columnpmo10010AlmClientRxPowerLowAlarmPortn | read-only | current | Client Trscv Rx Power Low Alarm :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indic… |
| 1.3.6.1.4.1.20044.76.2.2.1.56.1.3 | Columnpmo10010AlmClientRxPowerLowWarningPortn | read-only | current | Client Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning i… |
| 1.3.6.1.4.1.20044.76.2.2.1.56.1.4 | Columnpmo10010AlmClientRxPowerHighWarningPortn | read-only | current | Client Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning… |
| 1.3.6.1.4.1.20044.76.2.2.1.56.1.5 | Columnpmo10010AlmClientRxPowerHighAlarmPortn | read-only | current | Client Trscv Rx Power High Alarm :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm ind… |
| 1.3.6.1.4.1.20044.76.2.2.1.56.1.6 | Columnpmo10010AlmLaserTempLowAlarmPortn | read-only | current | Client Trscv Laser Temp Low Alarm :This OID indicates that the Trscv Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help> Ala… |
| 1.3.6.1.4.1.20044.76.2.2.1.56.1.7 | Columnpmo10010AlmClientLaserTempLowWarningPortn | read-only | current | Client Trscv Laser Temp Low Warning :This OID indicates that the Trscv Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help> W… |
| 1.3.6.1.4.1.20044.76.2.2.1.56.1.8 | Columnpmo10010AlmClientLaserTempHighWarningPortn | read-only | current | Client Trscv Laser Temp High Warning :This OID indicates that the Trscv Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Help>… |
| 1.3.6.1.4.1.20044.76.2.2.1.56.1.9 | Columnpmo10010AlmClientLaserTempHighAlarmPortn | read-only | current | Client Trscv Laser Temp High Alarm :This OID indicates that the Trscv Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Help> A… |
| 1.3.6.1.4.1.20044.76.2.2.1.56.1.10 | Columnpmo10010AlmClientTxPowerLowAlarmPortn | read-only | current | Client Trscv Tx Power Low Alarm :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indi… |
| 1.3.6.1.4.1.20044.76.2.2.1.56.1.11 | Columnpmo10010AlmClientTxPowerLowWarningPortn | read-only | current | Client Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning … |
| 1.3.6.1.4.1.20044.76.2.2.1.56.1.12 | Columnpmo10010AlmClientTxPowerHighWarningPortn | read-only | current | Client Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warnin… |
| 1.3.6.1.4.1.20044.76.2.2.1.56.1.13 | Columnpmo10010AlmClientTxPowerHighAlarmPortn | read-only | current | Client Trscv Tx Power High Alarm :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm in… |
| 1.3.6.1.4.1.20044.76.2.2.1.56.1.14 | Columnpmo10010AlmClientBiasLowAlarmPortn | read-only | current | Client Trscv Bias Low Alarm :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in… |
| 1.3.6.1.4.1.20044.76.2.2.1.56.1.15 | Columnpmo10010AlmClientBiasLowWarningPortn | read-only | current | Client Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warnin… |
| 1.3.6.1.4.1.20044.76.2.2.1.56.1.16 | Columnpmo10010AlmClientBiasHighWarningPortn | read-only | current | Client Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warn… |
| 1.3.6.1.4.1.20044.76.2.2.1.56.1.17 | Columnpmo10010AlmClientBiasHighAlarmPortn | read-only | current | Client Trscv Bias High Alarm :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Alarm … |
| 1.3.6.1.4.1.20044.76.2.2.1.232 | Tablepmo10010AlmclientSfpWarnDdmTable | not-accessible | current | List of pmo10010AlmclientSfpWarnDdm Article |
| 1.3.6.1.4.1.20044.76.2.2.1.232.1 | Rowpmo10010AlmclientSfpWarnDdmEntry | not-accessible | current | Row definition for the pmo10010AlmclientSfpWarnDdm table |
| 1.3.6.1.4.1.20044.76.2.2.1.232.1.1 | Columnpmo10010AlmclientSfpWarnDdmIndex | read-only | current | Index definition for the pmo10010AlmclientSfpWarnDdm table |
| 1.3.6.1.4.1.20044.76.2.2.1.232.1.2 | Columnpmo10010AlmTxPwLowWngPortn | read-only | current | Client Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning … |
| 1.3.6.1.4.1.20044.76.2.2.1.232.1.3 | Columnpmo10010AlmTxPwrHighWngPortn | read-only | current | Client Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warnin… |
| 1.3.6.1.4.1.20044.76.2.2.1.232.1.4 | Columnpmo10010AlmTxBiasLowWngPortn | read-only | current | Client Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warnin… |
| 1.3.6.1.4.1.20044.76.2.2.1.232.1.5 | Columnpmo10010AlmTxBiasHighWngPortn | read-only | current | Client Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warn… |
| 1.3.6.1.4.1.20044.76.2.2.1.232.1.6 | Columnpmo10010AlmVccLowWngPortn | read-only | current | Client Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Warn… |
| 1.3.6.1.4.1.20044.76.2.2.1.232.1.7 | Columnpmo10010AlmVccHighWngPortn | read-only | current | Client Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Wa… |
| 1.3.6.1.4.1.20044.76.2.2.1.232.1.8 | Columnpmo10010AlmTempLowWngPortn | read-only | current | Client Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indic… |
| 1.3.6.1.4.1.20044.76.2.2.1.232.1.9 | Columnpmo10010AlmTempHighWngPortn | read-only | current | Client Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning ind… |
| 1.3.6.1.4.1.20044.76.2.2.1.232.1.16 | Columnpmo10010AlmRxPwrLowWngPortn | read-only | current | Client Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning i… |
| 1.3.6.1.4.1.20044.76.2.2.1.232.1.17 | Columnpmo10010AlmRxPwrHighWngPortn | read-only | current | Client Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning… |
| 1.3.6.1.4.1.20044.76.2.2.2 | Nodepmo10010AlmClientUrg | |||
| 1.3.6.1.4.1.20044.76.2.2.2.72 | Tablepmo10010AlmclientNetworkLaneFaultTable | not-accessible | current | List of pmo10010AlmclientNetworkLaneFault Article |
| 1.3.6.1.4.1.20044.76.2.2.2.72.1 | Rowpmo10010AlmclientNetworkLaneFaultEntry | not-accessible | current | Row definition for the pmo10010AlmclientNetworkLaneFault table |
| 1.3.6.1.4.1.20044.76.2.2.2.72.1.1 | Columnpmo10010AlmclientNetworkLaneFaultIndex | read-only | current | Index definition for the pmo10010AlmclientNetworkLaneFault table |
| 1.3.6.1.4.1.20044.76.2.2.2.72.1.4 | Columnpmo10010AlmClientLaneRxFifoErrorPortn | read-only | current | Client Network Lane Rx FIFO Error :This OID indicates a Rx FIFO Error on the Client Trscv Network Lane <Help> Alarm indicating a Rx FIFO Error on the Client Tr… |
| 1.3.6.1.4.1.20044.76.2.2.2.72.1.5 | Columnpmo10010AlmClientLaneRxLolPortn | read-only | current | Client Network Lane Rx Loss Of Lock :This OID indicates a Rx Loss of Lock on the Client Trscv Network Lane <Help> Alarm indicating a Rx Loss of Lock on the Cli… |
| 1.3.6.1.4.1.20044.76.2.2.2.72.1.6 | Columnpmo10010AlmClientLaneRxLosPortn | read-only | current | Client Network Lane Rx Loss Of Signal :This OID indicates a Rx Loss of Signal on the Client Trscv Network Lane <Help> Alarm indicating a Rx Loss of Signal on t… |
| 1.3.6.1.4.1.20044.76.2.2.2.72.1.8 | Columnpmo10010AlmClientLaneTxLolPortn | read-only | current | Client Network Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Client Trscv Network Lane <Help> Alarm indicating a Tx Loss of Lock on the Cli… |
| 1.3.6.1.4.1.20044.76.2.2.2.72.1.9 | Columnpmo10010AlmClientLaneTxLosfPortn | read-only | current | Client Network Lane Tx Loss Of Signal Functionality :This OID indicates a Tx Loss of Signal Functionality on the Client Trscv Network Lane <Help> Alarm indicat… |
| 1.3.6.1.4.1.20044.76.2.2.2.72.1.15 | Columnpmo10010AlmClientLaneApdPowerSupplyPortn | read-only | current | Client Network Lane APD Power Supply :This OID indicates an APD Power supply failure on the Client Trscv Network Lane <Help> Alarm indicating an APD Power supp… |
| 1.3.6.1.4.1.20044.76.2.2.2.72.1.16 | Columnpmo10010AlmClientLaneWavelengthUnlockedPortn | read-only | current | Client Network Lane Wavelength Unlock :This OID indicates a Wavelength unlock on the Client Trscv Network Lane <Help> Alarm indicating a Wavelength unlock on t… |
| 1.3.6.1.4.1.20044.76.2.2.2.72.1.17 | Columnpmo10010AlmClientLaneTecFaultPortn | read-only | current | Client Network Lane TEC Fault :This OID indicates a TEC Fault on the Client Trscv Network Lane <Help> Alarm indicating a TEC Fault on the Client Trscv Network … |
| 1.3.6.1.4.1.20044.76.2.2.2.88 | Tablepmo10010AlmclientHostLaneFaultTable | not-accessible | current | List of pmo10010AlmclientHostLaneFault Article |
| 1.3.6.1.4.1.20044.76.2.2.2.88.1 | Rowpmo10010AlmclientHostLaneFaultEntry | not-accessible | current | Row definition for the pmo10010AlmclientHostLaneFault table |
| 1.3.6.1.4.1.20044.76.2.2.2.88.1.1 | Columnpmo10010AlmclientHostLaneFaultIndex | read-only | current | Index definition for the pmo10010AlmclientHostLaneFault table |
| 1.3.6.1.4.1.20044.76.2.2.2.88.1.2 | Columnpmo10010AlmClientRxLossOfSyncPortn | read-only | current | Client Rx Frame Alignment Loss :This OID indicates the module is not aligned with the Rx incoming Client signal <Help> Alarm indicating the module is not align… |
| 1.3.6.1.4.1.20044.76.2.2.2.88.1.3 | Columnpmo10010AlmClientInputLossOfSigPortn | read-only | current | Client Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Client Trscv <Help> Alarm indicating a Loss of Signal is detected on the Cl… |
| 1.3.6.1.4.1.20044.76.2.2.2.88.1.4 | Columnpmo10010AlmClientLanesMarkerUnlockPortn | read-only | current | Client Lanes Marker Unlock :This OID indicates the Client lanes marker alignment is not lock <Help> Alarm indicating the Client lanes marker alignment is not l… |
| 1.3.6.1.4.1.20044.76.2.2.2.88.1.5 | Columnpmo10010AlmClientLanes6466UnlockPortn | read-only | current | Client Lanes 64/66b Unlock :This OID indicates the Client 64/66b decoder is not lock <Help> Alarm indicating the Client 64/66b decoder is not lock <Condtype> C… |
| 1.3.6.1.4.1.20044.76.2.2.2.88.1.6 | Columnpmo10010AlmClientLanesNotAlignedPortn | read-only | current | Client Lanes Not Aligned :This OID indicates the Client lanes are not aligned <Help> Alarm indicating the Client lanes are not aligned <Condtype> CLIENT_LANES_… |
| 1.3.6.1.4.1.20044.76.2.2.2.88.1.7 | Columnpmo10010AlmClientCsfDetectedPortn | read-only | current | Client Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client… |
| 1.3.6.1.4.1.20044.76.2.2.2.88.1.10 | Columnpmo10010AlmClientTxHostLolPortn | read-only | current | Client Host Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Client Trscv Host Lane <Help> Alarm indicating a Tx Loss of Lock on the Client Tr… |
| 1.3.6.1.4.1.20044.76.2.2.2.88.1.11 | Columnpmo10010AlmClientLaneTxFifoErrorPortn | read-only | current | Client Host Lane Tx FIFO Error :This OID indicates a Tx FIFO Error on the Client Trscv Host Lane <Help> Alarm indicating a Tx FIFO Error on the Client Trscv Ho… |
| 1.3.6.1.4.1.20044.76.2.2.2.88.1.12 | Columnpmo10010AlmRxLocalFaultDetectedPortn | read-only | current | Rx Local Fault Signal Detected :This OID indicates a Local Fault Signal is detected on the client input port<Help> This alarm indicates a Local Fault Signal is… |
| 1.3.6.1.4.1.20044.76.2.2.2.88.1.13 | Columnpmo10010AlmRxRemoteFaultDetectedPortn | read-only | current | Rx Remote Fault Signal Detected :This OID indicates a Remote Fault Signal is detected on the client input port<Help> This alarm indicates a Remote Fault Signal… |
| 1.3.6.1.4.1.20044.76.2.2.2.88.1.14 | Columnpmo10010AlmTxLocalFaultDetectedPortn | read-only | current | Tx Local Fault Signal Detected :This OID indicates a Local Fault Signal is coming on the client port from the line side<Help> This alarm indicates a Local Faul… |
| 1.3.6.1.4.1.20044.76.2.2.2.88.1.15 | Columnpmo10010AlmTxRemoteFaultDetectedPortn | read-only | current | Tx Remote Fault Signal Detected :This OID indicates a Remote Fault Signal is coming on the client port from the line side<Help> This alarm indicates a Remote F… |
| 1.3.6.1.4.1.20044.76.2.2.2.88.1.16 | Columnpmo10010AlmClientTxLossOfSyncPortn | read-only | current | Client Tx Frame Alignment Loss :This OID indicates the module is not aligned with the Tx incoming Client signal<Help> Alarm indicating the module is not aligne… |
| 1.3.6.1.4.1.20044.76.2.2.2.200 | Tablepmo10010AlmclientOtnAlmTable | not-accessible | current | List of pmo10010AlmclientOtnAlm Article |
| 1.3.6.1.4.1.20044.76.2.2.2.200.1 | Rowpmo10010AlmclientOtnAlmEntry | not-accessible | current | Row definition for the pmo10010AlmclientOtnAlm table |
| 1.3.6.1.4.1.20044.76.2.2.2.200.1.1 | Columnpmo10010AlmclientOtnAlmIndex | read-only | current | Index definition for the pmo10010AlmclientOtnAlm table |
| 1.3.6.1.4.1.20044.76.2.2.2.200.1.2 | Columnpmo10010AlmClientOtu2eDlomPortn | read-only | current | OTU2e_DLOM :This OID indicates that a Loss Of Multiframe has been detected on client port<Help> This alarm indicates if a Loss Of Multiframe has been detected … |
| 1.3.6.1.4.1.20044.76.2.2.2.200.1.3 | Columnpmo10010AlmClientOtu2eDlofPortn | read-only | current | OTU2e_DLOF :This OID indicates the module is not aligned with the incoming Line signal<Help> Alarm indicating the module is not aligned with the incoming clien… |
| 1.3.6.1.4.1.20044.76.2.2.2.200.1.4 | Columnpmo10010AlmClientOdu2eDplmPortn | read-only | current | ODU2e DPLM :This OID indicates a Payload Mismatch is detected on the Client port<Help> Alarm indicating a Payload Mismatch <Condtype> CLIENT_ODU2E_DPLM <Probca… |
| 1.3.6.1.4.1.20044.76.2.2.2.200.1.6 | Columnpmo10010AlmClientOdu2eDdegPortn | read-only | current | ODU2e DDEG :This OID indicates that a Signal Degrade has been detected on client port<Help> Alarm indicating a Signal Degrade upon threshold and confirmation p… |
| 1.3.6.1.4.1.20044.76.2.2.2.200.1.7 | Columnpmo10010AlmClientCsfDetectedOtnPortn | read-only | current | ETH DCSF :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client Signal Fail has be… |
| 1.3.6.1.4.1.20044.76.2.2.2.200.1.8 | Columnpmo10010AlmClientOdu2eIaisPortn | read-only | current | ODU2e IAIS :This OID indicates that an Alarm Indication Signal has been inserted on client port <Help> This alarm indicates if an Alarm Indication Signal has b… |
| 1.3.6.1.4.1.20044.76.2.2.2.200.1.9 | Columnpmo10010AlmClientOdu2eDtimPortn | read-only | current | ODU2e DTIM :This OID indicates that a Trace Identifier Mismatch has been detected on client port<Help> This alarm indicates if an Trace Identifier Mismatch has… |
| 1.3.6.1.4.1.20044.76.2.2.2.200.1.10 | Columnpmo10010AlmClientOdu2eDaisPortn | read-only | current | ODU2e DAIS :This OID indicates that a Alarm Indication SIgnal has been detected on client port<Help> This alarm indicates if an Alarm Indication Signal has bee… |
| 1.3.6.1.4.1.20044.76.2.2.2.200.1.12 | Columnpmo10010AlmClientOdu2eIociPortn | read-only | current | ODU2e IOCI :This OID indicates that an Open Connection has been inserted on client port <Help> This alarm indicates if an Open Connection Indication has been i… |
| 1.3.6.1.4.1.20044.76.2.2.2.200.1.13 | Columnpmo10010AlmClientOdu2eDociPortn | read-only | current | ODU2e DOCI :This OID indicates that a Open Connection has been detected on client port <Help> This alarm indicates if an Open Connection Indication has been de… |
| 1.3.6.1.4.1.20044.76.2.2.2.200.1.14 | Columnpmo10010AlmClientOdu2eIbdiPortn | read-only | current | ODU2e IBDI :This OID indicates that a Backward Defect Indication has been inserted on client port <Help> This alarm indicates if a Backward Defect Indication h… |
| 1.3.6.1.4.1.20044.76.2.2.2.200.1.15 | Columnpmo10010AlmClientOdu2eDbdiPortn | read-only | current | ODU2e DBDI :This OID indicates that a Backward Defect Indication has been detected on client port<Help> This alarm indicates if a Backward Defect Indication ha… |
| 1.3.6.1.4.1.20044.76.2.2.2.200.1.16 | Columnpmo10010AlmClientOdu2eIlckPortn | read-only | current | ODU2e ILCK :This OID indicates that a Locked Indication has been inserted on client port <Help> This alarm indicates if a Locked Indication has been inserted o… |
| 1.3.6.1.4.1.20044.76.2.2.2.200.1.17 | Columnpmo10010AlmClientOdu2eDlckPortn | read-only | current | ODU2e DLCK :This OID indicates that a Locked Indication has been detected on client port <Help> This alarm indicates if a Locked Indication has been detected o… |
| 1.3.6.1.4.1.20044.76.2.2.2.216 | Tablepmo10010AlmclientSfpAlmDdmTable | not-accessible | current | List of pmo10010AlmclientSfpAlmDdm Article |
| 1.3.6.1.4.1.20044.76.2.2.2.216.1 | Rowpmo10010AlmclientSfpAlmDdmEntry | not-accessible | current | Row definition for the pmo10010AlmclientSfpAlmDdm table |
| 1.3.6.1.4.1.20044.76.2.2.2.216.1.1 | Columnpmo10010AlmclientSfpAlmDdmIndex | read-only | current | Index definition for the pmo10010AlmclientSfpAlmDdm table |
| 1.3.6.1.4.1.20044.76.2.2.2.216.1.2 | Columnpmo10010AlmTxPwrLowAlaPortn | read-only | current | Client Trscv Tx Power Low :This OID indicates that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in… |
| 1.3.6.1.4.1.20044.76.2.2.2.216.1.3 | Columnpmo10010AlmTxPwrHighAlaPortn | read-only | current | Client Trscv Tx Power High :This OID indicates that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm … |
| 1.3.6.1.4.1.20044.76.2.2.2.216.1.4 | Columnpmo10010AlmTxBiasLowAlaPortn | read-only | current | Client Trscv Bias Low :This OID indicates that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm … |
| 1.3.6.1.4.1.20044.76.2.2.2.216.1.5 | Columnpmo10010AlmTxBiasHighAlaPortn | read-only | current | Client Trscv Bias High :This OID indicates that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM <Help> Alar… |
| 1.3.6.1.4.1.20044.76.2.2.2.216.1.6 | Columnpmo10010AlmVccLowAlaPortn | read-only | current | Client Trscv Power Supply Low :This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM <Help> Alar… |
| 1.3.6.1.4.1.20044.76.2.2.2.216.1.7 | Columnpmo10010AlmVccHighAlaPortn | read-only | current | Client Trscv Power Supply High :This OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM <Help> Al… |
| 1.3.6.1.4.1.20044.76.2.2.2.216.1.8 | Columnpmo10010AlmTempLowAlaPortn | read-only | current | Client Trscv Temp Low :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicat… |
| 1.3.6.1.4.1.20044.76.2.2.2.216.1.9 | Columnpmo10010AlmTempHighAlaPortn | read-only | current | Client Trscv Temp High :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indic… |
| 1.3.6.1.4.1.20044.76.2.2.2.216.1.16 | Columnpmo10010AlmRxPwrLowAlaPortn | read-only | current | Client Trscv Rx Power Low :This OID indicates that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm ind… |
| 1.3.6.1.4.1.20044.76.2.2.2.216.1.17 | Columnpmo10010AlmRxPwrHighAlaPortn | read-only | current | Client Trscv Rx Power High :This OID indicates that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm i… |
| 1.3.6.1.4.1.20044.76.2.2.3 | Nodepmo10010AlmClientCrit | |||
| 1.3.6.1.4.1.20044.76.2.2.3.8 | Tablepmo10010AlmsynthAlmPortTable | not-accessible | current | List of pmo10010AlmsynthAlmPort Article |
| 1.3.6.1.4.1.20044.76.2.2.3.8.1 | Rowpmo10010AlmsynthAlmPortEntry | not-accessible | current | Row definition for the pmo10010AlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.76.2.2.3.8.1.1 | Columnpmo10010AlmsynthAlmPortIndex | read-only | current | Index definition for the pmo10010AlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.76.2.2.3.8.1.2 | Columnpmo10010AlmSfpAbsentPortn | read-only | current | Client Optical Module Absent :This OID indicates that the Transceiver is not present in the client port. <Help> This alarm indicates if the client transceiver … |
| 1.3.6.1.4.1.20044.76.2.2.3.8.1.3 | Columnpmo10010AlmDdmAbsentPortn | read-only | current | DDM Supported On Client Trscv :This OID indicates that the Client transceiver supports the Digital Diagnostic Monitoring function <Help> This status indicates … |
| 1.3.6.1.4.1.20044.76.2.2.3.8.1.5 | Columnpmo10010AlmHwFailAccPortn | read-only | current | Client HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Help> This alarm indicates a failure on client port, most pro… |
| 1.3.6.1.4.1.20044.76.2.2.3.8.1.6 | Columnpmo10010AlmDwLsdPortn | read-only | current | Client Trscv Laser Shutdown :This OID indicates the Client transceiver laser is shutdown <Help> This status indicates if the client transceiver laser is shutdo… |
| 1.3.6.1.4.1.20044.76.2.2.3.8.1.7 | Columnpmo10010AlmClientLocalOosPortn | read-only | current | Local Client Port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local c… |
| 1.3.6.1.4.1.20044.76.2.2.3.8.1.8 | Columnpmo10010AlmClientRemoteOosPortn | read-only | current | Remote Client Port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the remot… |
| 1.3.6.1.4.1.20044.76.2.2.3.8.1.9 | Columnpmo10010AlmDwCaisPortn | read-only | current | Client AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indicates if a Client Alarm Indication Signal is… |
| 1.3.6.1.4.1.20044.76.2.2.3.8.1.10 | Columnpmo10010AlmSfpDdmWarningPortn | read-only | current | Warning On Client Trscv DDM :This OID indicates a warning is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Warning has be… |
| 1.3.6.1.4.1.20044.76.2.2.3.8.1.11 | Columnpmo10010AlmSfpDdmAlmPortn | read-only | current | Alarm On Client Trscv DDM :This OID indicates an alarm is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Alarm has been de… |
| 1.3.6.1.4.1.20044.76.2.2.3.8.1.13 | Columnpmo10010AlmFailAccPortn | read-only | current | Client Access Fail :This OID indicates a failure on the Client port <Help> This alarm indicates a failure on the Client port <Condtype> FAIL_ACC_1 <Probcause> … |
| 1.3.6.1.4.1.20044.76.2.2.3.8.1.17 | Columnpmo10010AlmUpCsfPortn | read-only | current | Client Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu… |
| 1.3.6.1.4.1.20044.76.2.3 | Nodepmo10010AlmLine | |||
| 1.3.6.1.4.1.20044.76.2.3.1 | Nodepmo10010AlmLineNurg | |||
| 1.3.6.1.4.1.20044.76.2.3.1.104 | Tablepmo10010AlmlineNetworkLaneAlarmWarning1Table | not-accessible | current | List of pmo10010AlmlineNetworkLaneAlarmWarning1 Article |
| 1.3.6.1.4.1.20044.76.2.3.1.104.1 | Rowpmo10010AlmlineNetworkLaneAlarmWarning1Entry | not-accessible | current | Row definition for the pmo10010AlmlineNetworkLaneAlarmWarning1 table |
| 1.3.6.1.4.1.20044.76.2.3.1.104.1.1 | Columnpmo10010AlmlineNetworkLaneAlarmWarning1Index | read-only | current | Index definition for the pmo10010AlmlineNetworkLaneAlarmWarning1 table |
| 1.3.6.1.4.1.20044.76.2.3.1.104.1.2 | Columnpmo10010AlmLineRxPowerLowAlarmPortn | read-only | current | Line Trscv Rx Power Low Alarm :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicat… |
| 1.3.6.1.4.1.20044.76.2.3.1.104.1.3 | Columnpmo10010AlmLineRxPowerLowWarningPortn | read-only | current | Line Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning ind… |
| 1.3.6.1.4.1.20044.76.2.3.1.104.1.4 | Columnpmo10010AlmLineRxPowerHighWarningPortn | read-only | current | Line Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning i… |
| 1.3.6.1.4.1.20044.76.2.3.1.104.1.5 | Columnpmo10010AlmLineRxPowerHighAlarmPortn | read-only | current | Line Trscv Rx Power High Alarm :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indic… |
| 1.3.6.1.4.1.20044.76.2.3.1.104.1.6 | Columnpmo10010AlmLineLaserTempLowAlarmPortn | read-only | current | Line Trscv Tx Laser Temp Low Alarm :This OID indicates that the Trscv Tx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help>… |
| 1.3.6.1.4.1.20044.76.2.3.1.104.1.7 | Columnpmo10010AlmLineLaserTempLowWarningPortn | read-only | current | Line Trscv Tx Laser Temp Low Warning :This OID indicates that the Trscv Tx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Hel… |
| 1.3.6.1.4.1.20044.76.2.3.1.104.1.8 | Columnpmo10010AlmLineLaserTempHighWarningPortn | read-only | current | Line Trscv Tx Laser Temp High Warning :This OID indicates that the Trscv Tx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <H… |
| 1.3.6.1.4.1.20044.76.2.3.1.104.1.9 | Columnpmo10010AlmLineLaserTempHighAlarmPortn | read-only | current | Line Trscv Tx Laser Temp High Alarm :This OID indicates that the Trscv Tx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Hel… |
| 1.3.6.1.4.1.20044.76.2.3.1.104.1.10 | Columnpmo10010AlmLineTxPowerLowAlarmPortn | read-only | current | Line Trscv Tx Power Low Alarm :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indica… |
| 1.3.6.1.4.1.20044.76.2.3.1.104.1.11 | Columnpmo10010AlmLineTxPowerLowWarningPortn | read-only | current | Line Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning in… |
| 1.3.6.1.4.1.20044.76.2.3.1.104.1.12 | Columnpmo10010AlmLineTxPowerHighWarningPortn | read-only | current | Line Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warning … |
| 1.3.6.1.4.1.20044.76.2.3.1.104.1.13 | Columnpmo10010AlmLineTxPowerHighAlarmPortn | read-only | current | Line Trscv Tx Power High Alarm :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indi… |
| 1.3.6.1.4.1.20044.76.2.3.1.104.1.14 | Columnpmo10010AlmLineBiasLowAlarmPortn | read-only | current | Line Trscv Tx Bias Low Alarm :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alarm i… |
| 1.3.6.1.4.1.20044.76.2.3.1.104.1.15 | Columnpmo10010AlmLineBiasLowWarningPortn | read-only | current | Line Trscv Tx Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warni… |
| 1.3.6.1.4.1.20044.76.2.3.1.104.1.16 | Columnpmo10010AlmLineBiasHighWarningPortn | read-only | current | Line Trscv Tx Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> War… |
| 1.3.6.1.4.1.20044.76.2.3.1.104.1.17 | Columnpmo10010AlmLineBiasHighAlarmPortn | read-only | current | Line Trscv Tx Bias High Alarm :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Alarm… |
| 1.3.6.1.4.1.20044.76.2.3.1.120 | Tablepmo10010AlmlineNetworkLaneAlarmWarning2Table | not-accessible | current | List of pmo10010AlmlineNetworkLaneAlarmWarning2 Article |
| 1.3.6.1.4.1.20044.76.2.3.1.120.1 | Rowpmo10010AlmlineNetworkLaneAlarmWarning2Entry | not-accessible | current | Row definition for the pmo10010AlmlineNetworkLaneAlarmWarning2 table |
| 1.3.6.1.4.1.20044.76.2.3.1.120.1.1 | Columnpmo10010AlmlineNetworkLaneAlarmWarning2Index | read-only | current | Index definition for the pmo10010AlmlineNetworkLaneAlarmWarning2 table |
| 1.3.6.1.4.1.20044.76.2.3.1.120.1.2 | Columnpmo10010AlmTxModulatorBiasLowAlarmPortn | read-only | current | Line Trscv Tx Modulator Bias Low Alarm :This OID indicates that the Trscv Tx modulator bias current is lower than the threshold value written in the Trscv EEPR… |
| 1.3.6.1.4.1.20044.76.2.3.1.120.1.3 | Columnpmo10010AlmTxModulatorBiasLowWarningPortn | read-only | current | Line Trscv Tx Modulator Bias Low Warning :This OID indicates that the Trscv Tx modulator bias current is lower than the threshold value written in the Trscv EE… |
| 1.3.6.1.4.1.20044.76.2.3.1.120.1.4 | Columnpmo10010AlmTxModulatorBiasHighWarningPortn | read-only | current | Line Trscv Tx Modulator Bias High Warning :This OID indicates that the Trscv Tx modulator bias current is higher than the threshold value written in the Trscv … |
| 1.3.6.1.4.1.20044.76.2.3.1.120.1.5 | Columnpmo10010AlmTxModulatorBiasHighAlarmPortn | read-only | current | Line Trscv Tx Modulator Bias High Alarm :This OID indicates that the Trscv Tx modulator bias current is higher than the threshold value written in the Trscv EE… |
| 1.3.6.1.4.1.20044.76.2.3.1.120.1.6 | Columnpmo10010AlmRxLaserTempLowAlarmPortn | read-only | current | Line Trscv Rx Laser Temp Low Alarm :This OID indicates that the Trscv Rx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help>… |
| 1.3.6.1.4.1.20044.76.2.3.1.120.1.7 | Columnpmo10010AlmRxLaserTempLowWarningPortn | read-only | current | Line Trscv Rx Laser Temp Low Warning :This OID indicates that the Trscv Rx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Hel… |
| 1.3.6.1.4.1.20044.76.2.3.1.120.1.8 | Columnpmo10010AlmRxLaserTempHighWarningPortn | read-only | current | Line Trscv Rx Laser Temp High Warning :This OID indicates that the Trscv Rx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <H… |
| 1.3.6.1.4.1.20044.76.2.3.1.120.1.9 | Columnpmo10010AlmRxLaserTempHighAlarmPortn | read-only | current | Line Trscv Rx Laser Temp High Alarm :This OID indicates that the Trscv Rx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Hel… |
| 1.3.6.1.4.1.20044.76.2.3.1.120.1.10 | Columnpmo10010AlmRxLaserOutputLowAlarmPortn | read-only | current | Line Trscv Rx Output Power Low Alarm :This OID indicates that the Trscv Rx output power is lower than the threshold value written in the Trscv EEPROM <Help> Al… |
| 1.3.6.1.4.1.20044.76.2.3.1.120.1.11 | Columnpmo10010AlmRxLaserOutputLowWarningPortn | read-only | current | Line Trscv Rx Output Power Low Warning :This OID indicates that the Trscv Rx output power is lower than the threshold value written in the Trscv EEPROM <Help> … |
| 1.3.6.1.4.1.20044.76.2.3.1.120.1.12 | Columnpmo10010AlmRxLaserOutputHighWarningPortn | read-only | current | Line Trscv Rx Output Power High Warning :This OID indicates that the Trscv Rx output power is higher than the threshold value written in the Trscv EEPROM <Help… |
| 1.3.6.1.4.1.20044.76.2.3.1.120.1.13 | Columnpmo10010AlmRxLaserOutputHighAlarmPortn | read-only | current | Line Trscv Rx Output Power High Alarm :This OID indicates that the Trscv Rx output power is higher than the threshold value written in the Trscv EEPROM <Help> … |
| 1.3.6.1.4.1.20044.76.2.3.1.120.1.14 | Columnpmo10010AlmRxLaserBiasLowAlarmPortn | read-only | current | Line Trscv Rx Bias Low Alarm :This OID indicates that the Trscv Rx laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alar… |
| 1.3.6.1.4.1.20044.76.2.3.1.120.1.15 | Columnpmo10010AlmRxLaserBiasLowWarningPortn | read-only | current | Line Trscv Rx Bias Low Warning :This OID indicates that the Trscv Rx laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Wa… |
| 1.3.6.1.4.1.20044.76.2.3.1.120.1.16 | Columnpmo10010AlmRxLaserBiasHighWarningPortn | read-only | current | Line Trscv Rx Bias High Warning :This OID indicates that the Trscv Rx laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> … |
| 1.3.6.1.4.1.20044.76.2.3.1.120.1.17 | Columnpmo10010AlmRxLaserBiasHighAlarmPortn | read-only | current | Line Trscv Rx Bias High Alarm :This OID indicates that the Trscv Rx laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Al… |
| 1.3.6.1.4.1.20044.76.2.3.2 | Nodepmo10010AlmLineUrg | |||
| 1.3.6.1.4.1.20044.76.2.3.2.136 | Tablepmo10010AlmlineNetworkLaneFaultTable | not-accessible | current | List of pmo10010AlmlineNetworkLaneFault Article |
| 1.3.6.1.4.1.20044.76.2.3.2.136.1 | Rowpmo10010AlmlineNetworkLaneFaultEntry | not-accessible | current | Row definition for the pmo10010AlmlineNetworkLaneFault table |
| 1.3.6.1.4.1.20044.76.2.3.2.136.1.1 | Columnpmo10010AlmlineNetworkLaneFaultIndex | read-only | current | Index definition for the pmo10010AlmlineNetworkLaneFault table |
| 1.3.6.1.4.1.20044.76.2.3.2.136.1.3 | Columnpmo10010AlmLineLaneRxTecFaultPortn | read-only | current | Line Network Lane Rx TEC Fault :This OID indicates a Rx TEC Fault on the Line Trscv Network Lane <Help> Alarm indicating a Rx TEC Fault on the Line Trscv Netwo… |
| 1.3.6.1.4.1.20044.76.2.3.2.136.1.4 | Columnpmo10010AlmLineLaneRxFifoErrorPortn | read-only | current | Line Network Lane Rx FIFO Error :This OID indicates a Rx FIFO Error on the Line Trscv Network Lane <Help> Alarm indicating a Rx FIFO Error on the Line Trscv Ne… |
| 1.3.6.1.4.1.20044.76.2.3.2.136.1.5 | Columnpmo10010AlmLineLaneRxLolPortn | read-only | current | Line Network Lane Rx Loss Of Lock :This OID indicates a Rx Loss of Lock on the Line Trscv Network Lane <Help> Alarm indicating a Rx Loss of Lock on the Line Tr… |
| 1.3.6.1.4.1.20044.76.2.3.2.136.1.6 | Columnpmo10010AlmLineLaneRxLosPortn | read-only | current | Line Network Lane Rx Loss Of Signal :This OID indicates a Rx Loss of Signal on the Line Trscv Network Lane <Help> Alarm indicating a Rx Loss of Signal on the L… |
| 1.3.6.1.4.1.20044.76.2.3.2.136.1.8 | Columnpmo10010AlmLineLaneTxLolPortn | read-only | current | Line Network Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Line Trscv Network Lane <Help> Alarm indicating a Tx Loss of Lock on the Line Tr… |
| 1.3.6.1.4.1.20044.76.2.3.2.136.1.9 | Columnpmo10010AlmLineLaneTxLosfPortn | read-only | current | Line Network Lane Tx Loss Of Signal Functionality :This OID indicates a Tx Loss of Signal Functionality on the Line Trscv Network Lane <Help> Alarm indicating … |
| 1.3.6.1.4.1.20044.76.2.3.2.136.1.15 | Columnpmo10010AlmLineLaneApdPowerSupplyPortn | read-only | current | Line Network Lane APD Power Supply :This OID indicates an APD Power supply failure on the Line Trscv Network Lane <Help> Alarm indicating an APD Power supply f… |
| 1.3.6.1.4.1.20044.76.2.3.2.136.1.16 | Columnpmo10010AlmLineLaneWavelengthUnlockedPortn | read-only | current | Line Network Lane Wavelength Unlock :This OID indicates a Wavelength unlock on the Line Trscv Network Lane <Help> Alarm indicating a Wavelength unlock on the L… |
| 1.3.6.1.4.1.20044.76.2.3.2.136.1.17 | Columnpmo10010AlmLineLaneTecFaultPortn | read-only | current | Line Network Lane TEC Fault :This OID indicates a Tx TEC Fault on the Line Trscv Network Lane <Help> Alarm indicating a Tx TEC Fault on the Line Trscv Network … |
| 1.3.6.1.4.1.20044.76.2.3.2.152 | Tablepmo10010AlmlineOtu4AlarmTable | not-accessible | current | List of pmo10010AlmlineOtu4Alarm Article |
| 1.3.6.1.4.1.20044.76.2.3.2.152.1 | Rowpmo10010AlmlineOtu4AlarmEntry | not-accessible | current | Row definition for the pmo10010AlmlineOtu4Alarm table |
| 1.3.6.1.4.1.20044.76.2.3.2.152.1.1 | Columnpmo10010AlmlineOtu4AlarmIndex | read-only | current | Index definition for the pmo10010AlmlineOtu4Alarm table |
| 1.3.6.1.4.1.20044.76.2.3.2.152.1.2 | Columnpmo10010AlmLineInputLossOfSignalPortn | read-only | current | OPS4 DLOS-P :This OID indicates a Loss of Signal is detected on the Line Trscv <Help> Alarm indicating a Loss of Signal is detected on the Line Trscv <Condtype… |
| 1.3.6.1.4.1.20044.76.2.3.2.152.1.3 | Columnpmo10010AlmLineLossOfFramePortn | read-only | current | OTU4 - DLOF :This OID indicates the module is not aligned with the incoming Line signal <Help> Alarm indicating the module is not aligned with the incoming Lin… |
| 1.3.6.1.4.1.20044.76.2.3.2.152.1.4 | Columnpmo10010AlmLineSmBdiInsertedPortn | read-only | current | OTU4 IBDI :This OID indicates a SM Backward Defect Indication is inserted on the outgoing Line signal <Help> Status indicating a SM Backward Defect Indication … |
| 1.3.6.1.4.1.20044.76.2.3.2.152.1.5 | Columnpmo10010AlmLineSmBdiDetectedPortn | read-only | current | OTU4 DBDI :This OID indicates a SM Backward Defect Indication is detected on the incoming Line signal <Help> Alarm indicating a SM Backward Defect Indication i… |
| 1.3.6.1.4.1.20044.76.2.3.2.152.1.6 | Columnpmo10010AlmLineSmIaeInsertedPortn | read-only | current | Line SM IAE Inserted :This OID indicates a SM Incoming Alignment Error is inserted on the outgoing Line signal <Help> Status indicating a SM Incoming Alignment… |
| 1.3.6.1.4.1.20044.76.2.3.2.152.1.7 | Columnpmo10010AlmLineSmIaeDetectedPortn | read-only | current | Line SM IAE Detected :This OID indicates a SM Incoming Alignment Error is detected on the incoming Line signal <Help> Alarm indicating a SM Incoming Alignment … |
| 1.3.6.1.4.1.20044.76.2.3.2.152.1.8 | Columnpmo10010AlmOtu4DdegPortn | read-only | current | OTU4 DDEG :This OID indicates that a Signal Degrade has been detected on line port <Help> This alarm indicates if a Signal Degrade has been detected upon thres… |
| 1.3.6.1.4.1.20044.76.2.3.2.152.1.9 | Columnpmo10010AlmClientOtu4DtimPortn | read-only | current | OTU4 DTIM :This OID indicates that a Trace Identifier Mismatch has been detected on line port <Help> This alarm indicates if a Trace Identifier Mismatch has be… |
| 1.3.6.1.4.1.20044.76.2.3.2.152.1.10 | Columnpmo10010AlmLineTxHostLolPortn | read-only | current | Line Host Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Line Trscv Host Lane <Help> Alarm indicating a Tx Loss of Lock on the Line Trscv Ho… |
| 1.3.6.1.4.1.20044.76.2.3.2.152.1.11 | Columnpmo10010AlmLineLaneTxFifoErrorPortn | read-only | current | Line Host Lane Tx FIFO Error :This OID indicates a Tx FIFO Error on the Line Trscv Host Lane <Help> Alarm indicating a Tx FIFO Error on the Line Trscv Host Lan… |
| 1.3.6.1.4.1.20044.76.2.3.2.152.1.12 | Columnpmo10010AlmLineOchr4DlosPPortn | read-only | current | Ochr4 - DLOS-P :This OID indicates that a Transmitter failure has been detected on line port <Help> This alarm indicates if a Transmitter Failure has been dete… |
| 1.3.6.1.4.1.20044.76.2.3.2.152.1.16 | Columnpmo10010AlmLineOtu4DssfPortn | read-only | current | OTU4 DSSF :This OID indicates that a Server Signal failure has been detected on line port <Help> This alarm indicates if a Server Signal Failure has been detec… |
| 1.3.6.1.4.1.20044.76.2.3.2.152.1.17 | Columnpmo10010AlmLineOtu4DlomPortn | read-only | current | OTU4 DLOM :This OID indicates that a Loss Of Multiframe has been detected on line port <Help> This alarm indicates if a Loss Of Multiframe has been detected on… |
| 1.3.6.1.4.1.20044.76.2.3.2.168 | Tablepmo10010AlmlineNetworkLaneRxOtnTable | not-accessible | current | List of pmo10010AlmlineNetworkLaneRxOtn Article |
| 1.3.6.1.4.1.20044.76.2.3.2.168.1 | Rowpmo10010AlmlineNetworkLaneRxOtnEntry | not-accessible | current | Row definition for the pmo10010AlmlineNetworkLaneRxOtn table |
| 1.3.6.1.4.1.20044.76.2.3.2.168.1.1 | Columnpmo10010AlmlineNetworkLaneRxOtnIndex | read-only | current | Index definition for the pmo10010AlmlineNetworkLaneRxOtn table |
| 1.3.6.1.4.1.20044.76.2.3.2.168.1.10 | Columnpmo10010AlmLineRxOtnOduAisPortn | read-only | current | Line Network Rx ODU AIS :This OID indicates an ODU This OID Indication Signal is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating… |
| 1.3.6.1.4.1.20044.76.2.3.2.168.1.11 | Columnpmo10010AlmLineRxOtnOtuAisPortn | read-only | current | Line Network Rx OTU AIS :This OID indicates an OTU This OID Indication Signal is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating… |
| 1.3.6.1.4.1.20044.76.2.3.2.168.1.12 | Columnpmo10010AlmLineRxSmBdiPortn | read-only | current | Line Network Rx SM BDI :This OID indicates an SM Backward Defect Indication is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating a… |
| 1.3.6.1.4.1.20044.76.2.3.2.168.1.13 | Columnpmo10010AlmLineRxOtnIaePortn | read-only | current | Line Network Rx IAE :This OID indicates an Incoming Alignment Error is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating an Incomi… |
| 1.3.6.1.4.1.20044.76.2.3.2.168.1.14 | Columnpmo10010AlmLineRxOtnOomPortn | read-only | current | Line Network Rx OOM :This OID indicates an Out of Multiframe is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating an Out of Multif… |
| 1.3.6.1.4.1.20044.76.2.3.2.168.1.15 | Columnpmo10010AlmLineRxOtnLomPortn | read-only | current | Line Network Rx LOM :This OID indicates a Loss of Multiframe is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating a Loss of Multif… |
| 1.3.6.1.4.1.20044.76.2.3.2.168.1.16 | Columnpmo10010AlmLineRxOtnOofPortn | read-only | current | Line Network Rx OOF :This OID indicates an Out of Frame is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating an Out of Frame is de… |
| 1.3.6.1.4.1.20044.76.2.3.2.168.1.17 | Columnpmo10010AlmLineRxOtnLofPortn | read-only | current | Line Network Rx LOF :This OID indicates a Loss of Frame is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating a Loss of Frame is de… |
| 1.3.6.1.4.1.20044.76.2.3.2.184 | Tablepmo10010AlmlineHostLaneTxOtnTable | not-accessible | current | List of pmo10010AlmlineHostLaneTxOtn Article |
| 1.3.6.1.4.1.20044.76.2.3.2.184.1 | Rowpmo10010AlmlineHostLaneTxOtnEntry | not-accessible | current | Row definition for the pmo10010AlmlineHostLaneTxOtn table |
| 1.3.6.1.4.1.20044.76.2.3.2.184.1.1 | Columnpmo10010AlmlineHostLaneTxOtnIndex | read-only | current | Index definition for the pmo10010AlmlineHostLaneTxOtn table |
| 1.3.6.1.4.1.20044.76.2.3.2.184.1.10 | Columnpmo10010AlmLineTxOtnOduAisPortn | read-only | current | Line Host Tx ODU AIS :This OID indicates an ODU This OID Indication Signal is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an OD… |
| 1.3.6.1.4.1.20044.76.2.3.2.184.1.11 | Columnpmo10010AlmLineTxOtnOtuAisPortn | read-only | current | Line Host Tx OTU AIS :This OID indicates an OTU This OID Indication Signal is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an OT… |
| 1.3.6.1.4.1.20044.76.2.3.2.184.1.12 | Columnpmo10010AlmLineTxSmBdiPortn | read-only | current | Line Host Tx SM BDI :This OID indicates an SM Backward Defect Indication is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an SM B… |
| 1.3.6.1.4.1.20044.76.2.3.2.184.1.13 | Columnpmo10010AlmLineTxOtnIaePortn | read-only | current | Line Host Tx IAE :This OID indicates an Incoming Alignment Error is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an Incoming Ali… |
| 1.3.6.1.4.1.20044.76.2.3.2.184.1.14 | Columnpmo10010AlmLineTxOtnOomPortn | read-only | current | Line Host Tx OOM :This OID indicates an Out of Multiframe is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an Out of Multiframe i… |
| 1.3.6.1.4.1.20044.76.2.3.2.184.1.15 | Columnpmo10010AlmLineTxOtnLomPortn | read-only | current | Line Host Tx LOM :This OID indicates a Loss of Multiframe is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating a Loss of Multiframe i… |
| 1.3.6.1.4.1.20044.76.2.3.2.184.1.16 | Columnpmo10010AlmLineTxOtnOofPortn | read-only | current | Line Host Tx OOF :This OID indicates an Out of Frame is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an Out of Frame is detected… |
| 1.3.6.1.4.1.20044.76.2.3.2.184.1.17 | Columnpmo10010AlmLineTxOtnLofPortn | read-only | current | Line Host Tx LOF :This OID indicates a Loss of Frame is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating a Loss of Frame is detected… |
| 1.3.6.1.4.1.20044.76.2.3.2.256 | Tablepmo10010AlmlineOdu4AlmTable | not-accessible | current | List of pmo10010AlmlineOdu4Alm Article |
| 1.3.6.1.4.1.20044.76.2.3.2.256.1 | Rowpmo10010AlmlineOdu4AlmEntry | not-accessible | current | Row definition for the pmo10010AlmlineOdu4Alm table |
| 1.3.6.1.4.1.20044.76.2.3.2.256.1.1 | Columnpmo10010AlmlineOdu4AlmIndex | read-only | current | Index definition for the pmo10010AlmlineOdu4Alm table |
| 1.3.6.1.4.1.20044.76.2.3.2.256.1.4 | Columnpmo10010AlmLineOdu4DplmPortn | read-only | current | ODU4 DPLM :This OID indicates a Payload Mismatch is detected on the line port<Help> Alarm indicating a Payload Mismatch <Condtype> LINE_ODU4_DPLM <Probcause> r… |
| 1.3.6.1.4.1.20044.76.2.3.2.256.1.6 | Columnpmo10010AlmLineOdu4DdegPortn | read-only | current | ODU4 DDEG :This OID indicates that a Signal Degrade has been detected on line port<Help> Alarm indicating a Signal Degrade upon threshold and confirmation para… |
| 1.3.6.1.4.1.20044.76.2.3.2.256.1.8 | Columnpmo10010AlmLineOdu4IaisPortn | read-only | current | ODU4 IAIS :This OID indicates that an Alarm Indication Signal has been inserted on line port <Help> This alarm indicates if an Alarm Indication Signal has been… |
| 1.3.6.1.4.1.20044.76.2.3.2.256.1.9 | Columnpmo10010AlmLineOdu4DtimPortn | read-only | current | ODU4 DTIM :This OID indicates that a Trace Identifier Mismatch has been detected on line port<Help> This alarm indicates if an Trace Identifier Mismatch has be… |
| 1.3.6.1.4.1.20044.76.2.3.2.256.1.10 | Columnpmo10010AlmLineOdu4DaisPortn | read-only | current | ODU4 DAIS :This OID indicates that a Alarm Indication SIgnal has been detected on line port<Help> This alarm indicates if an Alarm Indication Signal has been d… |
| 1.3.6.1.4.1.20044.76.2.3.2.256.1.12 | Columnpmo10010AlmLineOdu4IociPortn | read-only | current | ODU4 IOCI :This OID indicates that an Open Connection has been inserted on line port <Help> This alarm indicates if an Open Connection Indication has been inse… |
| 1.3.6.1.4.1.20044.76.2.3.2.256.1.13 | Columnpmo10010AlmLineOdu4DociPortn | read-only | current | ODU4 DOCI :This OID indicates that a Open Connection has been detected on line port <Help> This alarm indicates if an Open Connection Indication has been detec… |
| 1.3.6.1.4.1.20044.76.2.3.2.256.1.14 | Columnpmo10010AlmLineOdu4IbdiPortn | read-only | current | ODU4 IBDI :This OID indicates that a Backward Defect Indication has been inserted on line port <Help> This alarm indicates if a Backward Defect Indication has … |
| 1.3.6.1.4.1.20044.76.2.3.2.256.1.15 | Columnpmo10010AlmLineOdu4DbdiPortn | read-only | current | ODU4 DBDI :This OID indicates that a Backward Defect Indication has been detected on line port<Help> This alarm indicates if a Backward Defect Indication has b… |
| 1.3.6.1.4.1.20044.76.2.3.2.256.1.16 | Columnpmo10010AlmLineOdu4IlckPortn | read-only | current | ODU4 ILCK :This OID indicates that a Locked Indication has been inserted on line port <Help> This alarm indicates if a Locked Indication has been inserted on t… |
| 1.3.6.1.4.1.20044.76.2.3.2.256.1.17 | Columnpmo10010AlmLineOdu4DlckPortn | read-only | current | ODU4 DLCK :This OID indicates that a Locked Indication has been detected on line port <Help> This alarm indicates if a Locked Indication has been detected on t… |
| 1.3.6.1.4.1.20044.76.2.3.3 | Nodepmo10010AlmLineCrit | |||
| 1.3.6.1.4.1.20044.76.2.3.3.24 | Tablepmo10010AlmsynthAlmLineTable | not-accessible | current | List of pmo10010AlmsynthAlmLine Article |
| 1.3.6.1.4.1.20044.76.2.3.3.24.1 | Rowpmo10010AlmsynthAlmLineEntry | not-accessible | current | Row definition for the pmo10010AlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.76.2.3.3.24.1.1 | Columnpmo10010AlmsynthAlmLineIndex | read-only | current | Index definition for the pmo10010AlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.76.2.3.3.24.1.2 | Columnpmo10010AlmXfpAbsentPortn | read-only | current | Line Optical Module Absent :This OID indicates that the line optical interface is not present. <Help> This alarm indicates if the line transceiver is not plugg… |
| 1.3.6.1.4.1.20044.76.2.3.3.24.1.3 | Columnpmo10010AlmXfpInitNotComplPortn | read-only | current | Line Optical Module Ready :This OID indicates that the optical interface is not operational. <Help> This status indicates if the line transceiver has been corr… |
| 1.3.6.1.4.1.20044.76.2.3.3.24.1.5 | Columnpmo10010AlmLineHwFailPortn | read-only | current | Line Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Help> This alarm indicates a failure on line port, most pr… |
| 1.3.6.1.4.1.20044.76.2.3.3.24.1.6 | Columnpmo10010AlmXfpTxOffPortn | read-only | current | Line Trscv Laser Shutdown :This OID indicates the Line transceiver laser is shutdown <Help> This status indicates if the Line transceiver laser is shutdown <Co… |
| 1.3.6.1.4.1.20044.76.2.3.3.24.1.7 | Columnpmo10010AlmLineLocalOosPortn | read-only | current | Line Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service… |
| 1.3.6.1.4.1.20044.76.2.3.3.24.1.9 | Columnpmo10010AlmUpRdiInsPortn | read-only | current | MS-RDI/L-RDI Inserted On Line :This OID indicates an upstream MS-RDI/L-RDI has been inserted in the outgoing 10 Gb/s SDH/SONET signal. <Help> This status indic… |
| 1.3.6.1.4.1.20044.76.2.3.3.24.1.10 | Columnpmo10010AlmLineDdmWarningPortn | read-only | current | Warning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Warning has… |
| 1.3.6.1.4.1.20044.76.2.3.3.24.1.11 | Columnpmo10010AlmLineDdmAlmPortn | read-only | current | Alarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Alarm has been… |
| 1.3.6.1.4.1.20044.76.2.3.3.24.1.13 | Columnpmo10010AlmLineFailPortn | read-only | current | Line Port Failure :This OID indicates a failure on the line port <Help> This alarm indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipm… |
| 1.3.6.1.4.1.20044.76.2.3.3.24.1.17 | Columnpmo10010AlmLineActivePortn | read-only | current | Line Active :This OID indicates whether the line is active or standby. <Help> This status indicates whether the line is active or standby. <Condtype> LINE_ACTI… |
| 1.3.6.1.4.1.20044.76.3 | Nodepmo10010measures | |||
| 1.3.6.1.4.1.20044.76.3.1 | Nodepmo10010MesrOther | |||
| 1.3.6.1.4.1.20044.76.3.1.0 | Scalarpmo10010Mesrsynth0 | read-only | deprecated | Not Used : |
| 1.3.6.1.4.1.20044.76.3.1.1 | Scalarpmo10010Mesrsynth1 | read-only | deprecated | Not Used : |
| 1.3.6.1.4.1.20044.76.3.1.7 | Scalarpmo10010MesrpmIntervalNumber | read-only | current | PM Interval Counter : |
| 1.3.6.1.4.1.20044.76.3.1.180 | Scalarpmo10010MesrlineNetTxLaserOutputPwrAverage | read-only | current | Average Line Trscv Tx Power :This OID gives the average Tx Laser transmit power value among the network lanes of the Line Transceiver, read in the DDM (Digital… |
| 1.3.6.1.4.1.20044.76.3.1.181 | Scalarpmo10010MesrlineNetTxLaserTempAverage | read-only | current | Average Line Trscv Tx Laser Temperature :This OID gives the average Tx Laser Temperature value among the network lanes of the Line Transceiver, read from the D… |
| 1.3.6.1.4.1.20044.76.3.1.182 | Scalarpmo10010MesrlineNetTxBiasCurrentAverage | read-only | current | Average Line Trscv Tx Laser Bias :This OID gives the average Tx Laser Bias value among the network lanes of the Line Transceiver, read from the DDM (Digital Di… |
| 1.3.6.1.4.1.20044.76.3.1.183 | Scalarpmo10010MesrlineNetRxInputPwrAverage | read-only | current | Average Line Trscv Rx Power :This OID gives the average Receive power value among the network lanes of the Line Transceiver, read in the DDM (Digital Diagnosti… |
| 1.3.6.1.4.1.20044.76.3.1.184 | Scalarpmo10010MesrlineResidualChromaticDispAverage | read-only | current | Average Residual Chromatic Dispersion :This OID gives the average Residual Chromatic Dispersion on the Line interface since the last measure reset <Help> This … |
| 1.3.6.1.4.1.20044.76.3.1.185 | Scalarpmo10010MesrlineDiffGroupDelayAverage | read-only | current | Average Differential Group Delay :This OID gives the average Group Delay on the Line interface since the last measure reset <Help> This measure gives the avera… |
| 1.3.6.1.4.1.20044.76.3.1.186 | Scalarpmo10010MesrlineQFactorAverage | read-only | current | Average Q Factor :This OID gives the average Q Factor on the Line interface since the last measure reset <Help> This measure gives the average Q Factor on the … |
| 1.3.6.1.4.1.20044.76.3.1.187 | Scalarpmo10010MesrlineCarrierFreqOffsetAverage | read-only | current | Average Carrier Frequency Offset :This OID gives the average Carrier Frequency Offset on the Line interface since the last measure reset <Help> This measure gi… |
| 1.3.6.1.4.1.20044.76.3.1.188 | Scalarpmo10010MesrlineOsnrAverage | read-only | current | Average OSNR :This OID gives the average OSNR on the Line interface since the last measure reset <Help> This measure gives the average OSNR on the Line interfa… |
| 1.3.6.1.4.1.20044.76.3.1.192 | Scalarpmo10010MesrclientNetTxTempMin | read-only | current | Min Client Trscv Laser Temperature :This OID gives the minimum Laser temperature value among the network lanes of the Client Transceiver, read from the DDM (Di… |
| 1.3.6.1.4.1.20044.76.3.1.193 | Scalarpmo10010MesrclientNetTxBiasMin | read-only | current | Min Client Trscv Laser Bias :This OID gives the minimum Laser bias value among the network lanes of the Client Transceiver, read from the DDM (Digital Diagnost… |
| 1.3.6.1.4.1.20044.76.3.1.194 | Scalarpmo10010MesrclientNetTxPwrMin | read-only | current | Min Client Trscv Tx Power :This OID gives the minimum transmit power value among the network lanes of the Client Transceiver, read from the DDM (Digital Diagno… |
| 1.3.6.1.4.1.20044.76.3.1.195 | Scalarpmo10010MesrclientNetRxPwrMin | read-only | current | Min Client Trscv Rx Power :This OID gives the minimum receive power value among the network lanes of the Client Transceiver, read in the DDM (Digital Diagnosti… |
| 1.3.6.1.4.1.20044.76.3.1.196 | Scalarpmo10010MesrlineNetTxLaserOutputPwrMin | read-only | current | Min Line Trscv Tx Power :This OID gives the minimum Tx Laser transmit power value among the network lanes of the Line Transceiver, read in the DDM (Digital Dia… |
| 1.3.6.1.4.1.20044.76.3.1.197 | Scalarpmo10010MesrlineNetTxLaserTempMin | read-only | current | Min Line Trscv Tx Laser Temperature :This OID gives the minimum Tx Laser Temperature value among the network lanes of the Line Transceiver, read from the DDM (… |
| 1.3.6.1.4.1.20044.76.3.1.198 | Scalarpmo10010MesrlineNetTxBiasCurrentMin | read-only | current | Min Line Trscv Tx Laser Bias :This OID gives the minimum Tx Laser Bias value among the network lanes of the Line Transceiver, read from the DDM (Digital Diagno… |
| 1.3.6.1.4.1.20044.76.3.1.199 | Scalarpmo10010MesrlineNetRxInputPwrMin | read-only | current | Min Line Trscv Rx Power :This OID gives the minimum Receive power value among the network lanes of the Line Transceiver, read in the DDM (Digital Diagnostic Mo… |
| 1.3.6.1.4.1.20044.76.3.1.200 | Scalarpmo10010MesrlineResidualChromaticDispMin | read-only | current | Min Residual Chromatic Dispersion :This OID gives the minimum Residual Chromatic Dispersion on the Line interface since the last measure reset (Unit = ps/nm)<H… |
| 1.3.6.1.4.1.20044.76.3.1.201 | Scalarpmo10010MesrlineDiffGroupDelayMin | read-only | current | Min Differential Group Delay :This OID gives the minimum Differential Group Delay on the Line interface since the last measure reset (Unit = ps)<Help> This mea… |
| 1.3.6.1.4.1.20044.76.3.1.202 | Scalarpmo10010MesrlineQFactorMin | read-only | current | Min Q Factor :This OID gives the minimum Q Factor on the Line interface since the last measure reset (Unit = dB)<Help> This measure gives the minimum Q Factor … |
| 1.3.6.1.4.1.20044.76.3.1.203 | Scalarpmo10010MesrlineCarrierFreqOffsetMin | read-only | current | Min Carrier Frequency Offset :This OID gives the minimum Carrier Frequency Offset on the Line interface since the last measure reset (Unit = Mhz)<Help> This me… |
| 1.3.6.1.4.1.20044.76.3.1.204 | Scalarpmo10010MesrlineOsnrMin | read-only | current | Min OSNR :This OID gives the minimum OSNR on the Line interface since the last measure reset (OSNR = AV/10) (Unit = dB)<Help> This measure gives the minimum OS… |
| 1.3.6.1.4.1.20044.76.3.1.208 | Scalarpmo10010MesrclientNetTxTempMax | read-only | current | Max Client Trscv Laser Temperature :This OID gives the maximum Laser temperature value among the network lanes of the Client Transceiver, read from the DDM (Di… |
| 1.3.6.1.4.1.20044.76.3.1.209 | Scalarpmo10010MesrclientNetTxBiasMax | read-only | current | Max Client Trscv Laser Bias :This OID gives the maximum Laser bias value among the network lanes of the Client Transceiver, read from the DDM (Digital Diagnost… |
| 1.3.6.1.4.1.20044.76.3.1.210 | Scalarpmo10010MesrclientNetTxPwrMax | read-only | current | Max Client Trscv Tx Power :This OID gives the maximum transmit power value among the network lanes of the Client Transceiver, read from the DDM (Digital Diagno… |
| 1.3.6.1.4.1.20044.76.3.1.211 | Scalarpmo10010MesrclientNetRxPwrMax | read-only | current | Max Client Trscv Rx Power :This OID gives the maximum receive power value among the network lanes of the Client Transceiver, read in the DDM (Digital Diagnosti… |
| 1.3.6.1.4.1.20044.76.3.1.212 | Scalarpmo10010MesrlineNetTxLaserOutputPwrMax | read-only | current | Max Line Trscv Tx Power :This OID gives the maximum Tx Laser transmit power value among the network lanes of the Line Transceiver, read in the DDM (Digital Dia… |
| 1.3.6.1.4.1.20044.76.3.1.213 | Scalarpmo10010MesrlineNetTxLaserTempMax | read-only | current | Max Line Trscv Tx Laser Temperature :This OID gives the maximum Tx Laser Temperature value among the network lanes of the Line Transceiver, read from the DDM (… |
| 1.3.6.1.4.1.20044.76.3.1.214 | Scalarpmo10010MesrlineNetTxBiasCurrentMax | read-only | current | Max Line Trscv Tx Laser Bias :This OID gives the maximum Tx Laser Bias value among the network lanes of the Line Transceiver, read from the DDM (Digital Diagno… |
| 1.3.6.1.4.1.20044.76.3.1.215 | Scalarpmo10010MesrlineNetRxInputPwrMax | read-only | current | Max Line Trscv Rx Power :This OID gives the maximum Receive power value among the network lanes of the Line Transceiver, read in the DDM (Digital Diagnostic Mo… |
| 1.3.6.1.4.1.20044.76.3.1.216 | Scalarpmo10010MesrlineResidualChromaticDispMax | read-only | current | Max Residual Chromatic Dispersion :This OID gives the maximum Residual Chromatic Dispersion on the Line interface since the last measure reset (Unit = ps/nm)<H… |
| 1.3.6.1.4.1.20044.76.3.1.217 | Scalarpmo10010MesrlineDiffGroupDelayMax | read-only | current | Max Differential Group Delay :This OID gives the maximum Differential Group Delay on the Line interface since the last measure reset (Unit = ps)<Help> This mea… |
| 1.3.6.1.4.1.20044.76.3.1.218 | Scalarpmo10010MesrlineQFactorMax | read-only | current | Max Q Factor :This OID gives the maximum Q Factor on the Line interface since the last measure reset (Unit = dB)<Help> This measure gives the maximum Q Factor … |
| 1.3.6.1.4.1.20044.76.3.1.219 | Scalarpmo10010MesrlineCarrierFreqOffsetMax | read-only | current | Max Carrier Frequency Offset :This OID gives the maximum Carrier Frequency Offset on the Line interface since the last measure reset (Unit = Mhz)<Help> This me… |
| 1.3.6.1.4.1.20044.76.3.1.220 | Scalarpmo10010MesrlineOsnrMax | read-only | current | Max OSNR :This OID gives the maximum OSNR on the Line interface since the last measure reset (OSNR = AV/10) (Unit = dB)<Help> This measure gives the maximum OS… |
| 1.3.6.1.4.1.20044.76.3.2 | Nodepmo10010MesrClient | |||
| 1.3.6.1.4.1.20044.76.3.2.8 | Scalarpmo10010MesrclientCfpTemp | read-only | current | Client Trscv Temperature :This OID gives the temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/2… |
| 1.3.6.1.4.1.20044.76.3.2.9 | Scalarpmo10010MesrclientCfp3v3Voltage | read-only | current | Client Trscv Voltage :This OID gives the 3V3 voltage value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/1000) (Un… |
| 1.3.6.1.4.1.20044.76.3.2.10 | Scalarpmo10010MesrclientSoaBiasCurrent | read-only | current | Client Trscv SOA Bias :This OID gives the SOA bias value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = m… |
| 1.3.6.1.4.1.20044.76.3.2.16 | Tablepmo10010MesrclientNetTxTempTable | not-accessible | current | List of pmo10010MesrclientNetTxTemp Article |
| 1.3.6.1.4.1.20044.76.3.2.16.1 | Rowpmo10010MesrclientNetTxTempEntry | not-accessible | current | Row definition for the pmo10010MesrclientNetTxTemp table |
| 1.3.6.1.4.1.20044.76.3.2.16.1.1 | Columnpmo10010MesrclientNetTxTempIndex | read-only | current | Index definition for the pmo10010MesrclientNetTxTemp table |
| 1.3.6.1.4.1.20044.76.3.2.16.1.2 | Columnpmo10010MesrclientNetTxTempPortn | read-only | current | Client Trscv Temperature :This OID gives the Laser temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature … |
| 1.3.6.1.4.1.20044.76.3.2.32 | Tablepmo10010MesrclientNetTxBiasTable | not-accessible | current | List of pmo10010MesrclientNetTxBias Article |
| 1.3.6.1.4.1.20044.76.3.2.32.1 | Rowpmo10010MesrclientNetTxBiasEntry | not-accessible | current | Row definition for the pmo10010MesrclientNetTxBias table |
| 1.3.6.1.4.1.20044.76.3.2.32.1.1 | Columnpmo10010MesrclientNetTxBiasIndex | read-only | current | Index definition for the pmo10010MesrclientNetTxBias table |
| 1.3.6.1.4.1.20044.76.3.2.32.1.2 | Columnpmo10010MesrclientNetTxBiasPortn | read-only | current | Client Trscv Laser Bias :This OID gives the Laser bias value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit… |
| 1.3.6.1.4.1.20044.76.3.2.48 | Tablepmo10010MesrclientNetTxPwrTable | not-accessible | current | List of pmo10010MesrclientNetTxPwr Article |
| 1.3.6.1.4.1.20044.76.3.2.48.1 | Rowpmo10010MesrclientNetTxPwrEntry | not-accessible | current | Row definition for the pmo10010MesrclientNetTxPwr table |
| 1.3.6.1.4.1.20044.76.3.2.48.1.1 | Columnpmo10010MesrclientNetTxPwrIndex | read-only | current | Index definition for the pmo10010MesrclientNetTxPwr table |
| 1.3.6.1.4.1.20044.76.3.2.48.1.2 | Columnpmo10010MesrclientNetTxPwrPortn | read-only | current | Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)… |
| 1.3.6.1.4.1.20044.76.3.2.64 | Tablepmo10010MesrclientNetRxPwrTable | not-accessible | current | List of pmo10010MesrclientNetRxPwr Article |
| 1.3.6.1.4.1.20044.76.3.2.64.1 | Rowpmo10010MesrclientNetRxPwrEntry | not-accessible | current | Row definition for the pmo10010MesrclientNetRxPwr table |
| 1.3.6.1.4.1.20044.76.3.2.64.1.1 | Columnpmo10010MesrclientNetRxPwrIndex | read-only | current | Index definition for the pmo10010MesrclientNetRxPwr table |
| 1.3.6.1.4.1.20044.76.3.2.64.1.2 | Columnpmo10010MesrclientNetRxPwrPortn | read-only | current | Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40… |
| 1.3.6.1.4.1.20044.76.3.3 | Nodepmo10010MesrLine | |||
| 1.3.6.1.4.1.20044.76.3.3.12 | Scalarpmo10010MesrlineMsaTemp | read-only | current | Line Trscv Temperature :This OID gives the temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) … |
| 1.3.6.1.4.1.20044.76.3.3.13 | Scalarpmo10010MesrlineMsa3v3Voltage | read-only | current | Line Trscv Voltage :This OID gives the 3V3 voltage value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/1000) (Unit =… |
| 1.3.6.1.4.1.20044.76.3.3.14 | Scalarpmo10010MesrlineSoaBiasCurrent | read-only | current | Line Trscv SOA Bias :This OID gives the SOA bias value of the Line Transceiver,read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <H… |
| 1.3.6.1.4.1.20044.76.3.3.80 | Tablepmo10010MesrlineNetTxLaserOutputPwrTable | not-accessible | current | List of pmo10010MesrlineNetTxLaserOutputPwr Article |
| 1.3.6.1.4.1.20044.76.3.3.80.1 | Rowpmo10010MesrlineNetTxLaserOutputPwrEntry | not-accessible | current | Row definition for the pmo10010MesrlineNetTxLaserOutputPwr table |
| 1.3.6.1.4.1.20044.76.3.3.80.1.1 | Columnpmo10010MesrlineNetTxLaserOutputPwrIndex | read-only | current | Index definition for the pmo10010MesrlineNetTxLaserOutputPwr table |
| 1.3.6.1.4.1.20044.76.3.3.80.1.2 | Columnpmo10010MesrlineNetTxLaserOutputPwrPortn | read-only | current | Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power =… |
| 1.3.6.1.4.1.20044.76.3.3.96 | Tablepmo10010MesrlineNetTxLaserTempTable | not-accessible | current | List of pmo10010MesrlineNetTxLaserTemp Article |
| 1.3.6.1.4.1.20044.76.3.3.96.1 | Rowpmo10010MesrlineNetTxLaserTempEntry | not-accessible | current | Row definition for the pmo10010MesrlineNetTxLaserTemp table |
| 1.3.6.1.4.1.20044.76.3.3.96.1.1 | Columnpmo10010MesrlineNetTxLaserTempIndex | read-only | current | Index definition for the pmo10010MesrlineNetTxLaserTemp table |
| 1.3.6.1.4.1.20044.76.3.3.96.1.2 | Columnpmo10010MesrlineNetTxLaserTempPortn | read-only | current | Current Line Trscv Tx Laser Temperature :This OID gives the Tx Laser Temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitorin… |
| 1.3.6.1.4.1.20044.76.3.3.112 | Tablepmo10010MesrlineNetTxBiasCurrentTable | not-accessible | current | List of pmo10010MesrlineNetTxBiasCurrent Article |
| 1.3.6.1.4.1.20044.76.3.3.112.1 | Rowpmo10010MesrlineNetTxBiasCurrentEntry | not-accessible | current | Row definition for the pmo10010MesrlineNetTxBiasCurrent table |
| 1.3.6.1.4.1.20044.76.3.3.112.1.1 | Columnpmo10010MesrlineNetTxBiasCurrentIndex | read-only | current | Index definition for the pmo10010MesrlineNetTxBiasCurrent table |
| 1.3.6.1.4.1.20044.76.3.3.112.1.2 | Columnpmo10010MesrlineNetTxBiasCurrentPortn | read-only | current | Current Line Trscv Tx Laser Bias :This OID gives the Tx Laser Bias value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/… |
| 1.3.6.1.4.1.20044.76.3.3.128 | Tablepmo10010MesrlineNetRxInputPwrTable | not-accessible | current | List of pmo10010MesrlineNetRxInputPwr Article |
| 1.3.6.1.4.1.20044.76.3.3.128.1 | Rowpmo10010MesrlineNetRxInputPwrEntry | not-accessible | current | Row definition for the pmo10010MesrlineNetRxInputPwr table |
| 1.3.6.1.4.1.20044.76.3.3.128.1.1 | Columnpmo10010MesrlineNetRxInputPwrIndex | read-only | current | Index definition for the pmo10010MesrlineNetRxInputPwr table |
| 1.3.6.1.4.1.20044.76.3.3.128.1.2 | Columnpmo10010MesrlineNetRxInputPwrPortn | read-only | current | Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (… |
| 1.3.6.1.4.1.20044.76.3.3.144 | Tablepmo10010MesrlineResidualChromaticDispTable | not-accessible | current | List of pmo10010MesrlineResidualChromaticDisp Article |
| 1.3.6.1.4.1.20044.76.3.3.144.1 | Rowpmo10010MesrlineResidualChromaticDispEntry | not-accessible | current | Row definition for the pmo10010MesrlineResidualChromaticDisp table |
| 1.3.6.1.4.1.20044.76.3.3.144.1.1 | Columnpmo10010MesrlineResidualChromaticDispIndex | read-only | current | Index definition for the pmo10010MesrlineResidualChromaticDisp table |
| 1.3.6.1.4.1.20044.76.3.3.144.1.2 | Columnpmo10010MesrlineResidualChromaticDispPortn | read-only | current | Current Residual Chromatic Dispersion :This OID gives the current Residual Chromatic Dispersion on the Line interface (Unit = ps/nm)<Help> This measure gives t… |
| 1.3.6.1.4.1.20044.76.3.3.148 | Tablepmo10010MesrlineDiffGroupDelayTable | not-accessible | current | List of pmo10010MesrlineDiffGroupDelay Article |
| 1.3.6.1.4.1.20044.76.3.3.148.1 | Rowpmo10010MesrlineDiffGroupDelayEntry | not-accessible | current | Row definition for the pmo10010MesrlineDiffGroupDelay table |
| 1.3.6.1.4.1.20044.76.3.3.148.1.1 | Columnpmo10010MesrlineDiffGroupDelayIndex | read-only | current | Index definition for the pmo10010MesrlineDiffGroupDelay table |
| 1.3.6.1.4.1.20044.76.3.3.148.1.2 | Columnpmo10010MesrlineDiffGroupDelayPortn | read-only | current | Current Differential Group Delay :This OID gives the current Differential Group Delay on the Line interface (Unit = ps)<Help> This measure gives the current Di… |
| 1.3.6.1.4.1.20044.76.3.3.152 | Tablepmo10010MesrlineQFactorTable | not-accessible | current | List of pmo10010MesrlineQFactor Article |
| 1.3.6.1.4.1.20044.76.3.3.152.1 | Rowpmo10010MesrlineQFactorEntry | not-accessible | current | Row definition for the pmo10010MesrlineQFactor table |
| 1.3.6.1.4.1.20044.76.3.3.152.1.1 | Columnpmo10010MesrlineQFactorIndex | read-only | current | Index definition for the pmo10010MesrlineQFactor table |
| 1.3.6.1.4.1.20044.76.3.3.152.1.2 | Columnpmo10010MesrlineQFactorPortn | read-only | current | Current Q Factor :This OID gives the current Q Factor on the Line interface (Unit = dB) <Help> This measure gives the current Q Factor on the Line interface. |
| 1.3.6.1.4.1.20044.76.3.3.156 | Tablepmo10010MesrlineCarrierFreqOffsetTable | not-accessible | current | List of pmo10010MesrlineCarrierFreqOffset Article |
| 1.3.6.1.4.1.20044.76.3.3.156.1 | Rowpmo10010MesrlineCarrierFreqOffsetEntry | not-accessible | current | Row definition for the pmo10010MesrlineCarrierFreqOffset table |
| 1.3.6.1.4.1.20044.76.3.3.156.1.1 | Columnpmo10010MesrlineCarrierFreqOffsetIndex | read-only | current | Index definition for the pmo10010MesrlineCarrierFreqOffset table |
| 1.3.6.1.4.1.20044.76.3.3.156.1.2 | Columnpmo10010MesrlineCarrierFreqOffsetPortn | read-only | current | Current Carrier Frequency Offset :This OID gives the current Carrier Frequency Offset on the Line interface (Unit = Mhz)<Help> This measure gives the current C… |
| 1.3.6.1.4.1.20044.76.3.3.160 | Tablepmo10010MesrlineOsnrTable | not-accessible | current | List of pmo10010MesrlineOsnr Article |
| 1.3.6.1.4.1.20044.76.3.3.160.1 | Rowpmo10010MesrlineOsnrEntry | not-accessible | current | Row definition for the pmo10010MesrlineOsnr table |
| 1.3.6.1.4.1.20044.76.3.3.160.1.1 | Columnpmo10010MesrlineOsnrIndex | read-only | current | Index definition for the pmo10010MesrlineOsnr table |
| 1.3.6.1.4.1.20044.76.3.3.160.1.2 | Columnpmo10010MesrlineOsnrPortn | read-only | current | Current OSNR :This OID gives the current OSNR on the Line interface (OSNR = AV/10) (Unit = dB)<Help> This measure gives the current OSNR on the Line interface. |
| 1.3.6.1.4.1.20044.76.4 | Nodepmo10010counters | |||
| 1.3.6.1.4.1.20044.76.4.1 | Nodepmo10010CntOther | |||
| 1.3.6.1.4.1.20044.76.4.2 | Nodepmo10010CntClient | |||
| 1.3.6.1.4.1.20044.76.4.2.16 | Tablepmo10010CntclientInputErrorCounterLaneOneTable | not-accessible | current | List of pmo10010CntclientInputErrorCounterLaneOne Article |
| 1.3.6.1.4.1.20044.76.4.2.16.1 | Rowpmo10010CntclientInputErrorCounterLaneOneEntry | not-accessible | current | Row definition for the pmo10010CntclientInputErrorCounterLaneOne table |
| 1.3.6.1.4.1.20044.76.4.2.16.1.1 | Columnpmo10010CntclientInputErrorCounterLaneOneIndex | read-only | current | Index definition for the pmo10010CntclientInputErrorCounterLaneOne table |
| 1.3.6.1.4.1.20044.76.4.2.16.1.2 | Columnpmo10010CntclientInputErrorCounterLaneOneValuePortn | read-only | current | Client_Input_Error_Counter_Lane1 :This counter is incremented each time a coding violation is detected on the host lane of the client transceiver <Help> This c… |
| 1.3.6.1.4.1.20044.76.4.2.16.1.3 | Columnpmo10010CntclientInputErrorCounterLaneOneErrorPortn | read-only | current | Client Input Counter Error :This OID when set indicates the rate adaptation removal counter value is invalid on Port |
| 1.3.6.1.4.1.20044.76.4.2.16.1.4 | Columnpmo10010CntclientInputErrorCounterLaneOneOverloadPortn | read-only | current | Client Input Counter Overload :This OID when set indicates a rate adaptation removal counter overload on Port |
| 1.3.6.1.4.1.20044.76.4.2.32 | Tablepmo10010CntclientInputErrorCounterLaneTwoTable | not-accessible | current | List of pmo10010CntclientInputErrorCounterLaneTwo Article |
| 1.3.6.1.4.1.20044.76.4.2.32.1 | Rowpmo10010CntclientInputErrorCounterLaneTwoEntry | not-accessible | current | Row definition for the pmo10010CntclientInputErrorCounterLaneTwo table |
| 1.3.6.1.4.1.20044.76.4.2.32.1.1 | Columnpmo10010CntclientInputErrorCounterLaneTwoIndex | read-only | current | Index definition for the pmo10010CntclientInputErrorCounterLaneTwo table |
| 1.3.6.1.4.1.20044.76.4.2.32.1.2 | Columnpmo10010CntclientInputErrorCounterLaneTwoValuePortn | read-only | current | Client_Input_Error_Counter_Lane2 :This counter is incremented each time a coding violation is detected on the host lane of the client transceiver <Help> This c… |
| 1.3.6.1.4.1.20044.76.4.2.32.1.3 | Columnpmo10010CntclientInputErrorCounterLaneTwoErrorPortn | read-only | current | Client Input Counter Error :This OID when set indicates the client error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.76.4.2.32.1.4 | Columnpmo10010CntclientInputErrorCounterLaneTwoOverloadPortn | read-only | current | Client Input Counter Overload :This OID when set indicates a client input error counter overload on Port |
| 1.3.6.1.4.1.20044.76.4.2.80 | Tablepmo10010CntclientInputErrorCounterTable | not-accessible | current | List of pmo10010CntclientInputErrorCounter Article |
| 1.3.6.1.4.1.20044.76.4.2.80.1 | Rowpmo10010CntclientInputErrorCounterEntry | not-accessible | current | Row definition for the pmo10010CntclientInputErrorCounter table |
| 1.3.6.1.4.1.20044.76.4.2.80.1.1 | Columnpmo10010CntclientInputErrorCounterIndex | read-only | current | Index definition for the pmo10010CntclientInputErrorCounter table |
| 1.3.6.1.4.1.20044.76.4.2.80.1.2 | Columnpmo10010CntclientInputErrorCounterValuePortn | read-only | current | Client Input Errors :This counter is increased each time an error is detected on the Client input stream <Help> This counter gives the number of CBIP errors (a… |
| 1.3.6.1.4.1.20044.76.4.2.80.1.3 | Columnpmo10010CntclientInputErrorCounterErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the client error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.76.4.2.80.1.4 | Columnpmo10010CntclientInputErrorCounterOverloadPortn | read-only | current | Client Counter Overload :This OID when set indicates a client input error counter overload on Port |
| 1.3.6.1.4.1.20044.76.4.2.96 | Tablepmo10010CntclientOutputErrorCounterTable | not-accessible | current | List of pmo10010CntclientOutputErrorCounter Article |
| 1.3.6.1.4.1.20044.76.4.2.96.1 | Rowpmo10010CntclientOutputErrorCounterEntry | not-accessible | current | Row definition for the pmo10010CntclientOutputErrorCounter table |
| 1.3.6.1.4.1.20044.76.4.2.96.1.1 | Columnpmo10010CntclientOutputErrorCounterIndex | read-only | current | Index definition for the pmo10010CntclientOutputErrorCounter table |
| 1.3.6.1.4.1.20044.76.4.2.96.1.2 | Columnpmo10010CntclientOutputErrorCounterValuePortn | read-only | current | Client Output Errors :This counter is increased each time an error is detected on the Client output stream <Help> This counter gives the number of CBIP errors … |
| 1.3.6.1.4.1.20044.76.4.2.96.1.3 | Columnpmo10010CntclientOutputErrorCounterErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the client error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.76.4.2.96.1.4 | Columnpmo10010CntclientOutputErrorCounterOverloadPortn | read-only | current | Client Counter Overload :This OID when set indicates a client input error counter overload on Port |
| 1.3.6.1.4.1.20044.76.4.3 | Nodepmo10010CntLine | |||
| 1.3.6.1.4.1.20044.76.4.3.192 | Tablepmo10010CntlocalLineSmBlockErrorCounterTable | not-accessible | current | List of pmo10010CntlocalLineSmBlockErrorCounter Article |
| 1.3.6.1.4.1.20044.76.4.3.192.1 | Rowpmo10010CntlocalLineSmBlockErrorCounterEntry | not-accessible | current | Row definition for the pmo10010CntlocalLineSmBlockErrorCounter table |
| 1.3.6.1.4.1.20044.76.4.3.192.1.1 | Columnpmo10010CntlocalLineSmBlockErrorCounterIndex | read-only | current | Index definition for the pmo10010CntlocalLineSmBlockErrorCounter table |
| 1.3.6.1.4.1.20044.76.4.3.192.1.2 | Columnpmo10010CntlocalLineSmBlockErrorCounterValuePortn | read-only | current | Line Input SM-Block Errors :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC <Help> This counter gives the current Bit Error Rate (… |
| 1.3.6.1.4.1.20044.76.4.3.192.1.3 | Columnpmo10010CntlocalLineSmBlockErrorCounterErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the B1 error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.76.4.3.192.1.4 | Columnpmo10010CntlocalLineSmBlockErrorCounterOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a B1 error counter overload on Port |
| 1.3.6.1.4.1.20044.76.4.3.193 | Tablepmo10010CntlocalLineFecCorrectedErrorsCounterTable | not-accessible | current | List of pmo10010CntlocalLineFecCorrectedErrorsCounter Article |
| 1.3.6.1.4.1.20044.76.4.3.193.1 | Rowpmo10010CntlocalLineFecCorrectedErrorsCounterEntry | not-accessible | current | Row definition for the pmo10010CntlocalLineFecCorrectedErrorsCounter table |
| 1.3.6.1.4.1.20044.76.4.3.193.1.1 | Columnpmo10010CntlocalLineFecCorrectedErrorsCounterIndex | read-only | current | Index definition for the pmo10010CntlocalLineFecCorrectedErrorsCounter table |
| 1.3.6.1.4.1.20044.76.4.3.193.1.2 | Columnpmo10010CntlocalLineFecCorrectedErrorsCounterValuePortn | read-only | current | Line Input FEC Corrected Errors :This OID gives the current Bit Error Rate before the Hard Decision FEC <Help> This counter gives the current Bit Error Rate be… |
| 1.3.6.1.4.1.20044.76.4.3.193.1.3 | Columnpmo10010CntlocalLineFecCorrectedErrorsCounterErrorPortn | read-only | current | FEC Counter Error :This bit when set indicates the FEC corrected errors counter value is invalid on Line |
| 1.3.6.1.4.1.20044.76.4.3.193.1.4 | Columnpmo10010CntlocalLineFecCorrectedErrorsCounterOverloadPortn | read-only | current | FEC Counter Overload :This bit when set indicates a FEC corrected errors counter overload on Line |
| 1.3.6.1.4.1.20044.76.4.3.194 | Tablepmo10010CntremoteLineSmBlockErrorCounterTable | not-accessible | current | List of pmo10010CntremoteLineSmBlockErrorCounter Article |
| 1.3.6.1.4.1.20044.76.4.3.194.1 | Rowpmo10010CntremoteLineSmBlockErrorCounterEntry | not-accessible | current | Row definition for the pmo10010CntremoteLineSmBlockErrorCounter table |
| 1.3.6.1.4.1.20044.76.4.3.194.1.1 | Columnpmo10010CntremoteLineSmBlockErrorCounterIndex | read-only | current | Index definition for the pmo10010CntremoteLineSmBlockErrorCounter table |
| 1.3.6.1.4.1.20044.76.4.3.194.1.2 | Columnpmo10010CntremoteLineSmBlockErrorCounterValuePortn | read-only | current | Remote SM Block Errors :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC on the remote side <Help> This counter gives the current B… |
| 1.3.6.1.4.1.20044.76.4.3.194.1.3 | Columnpmo10010CntremoteLineSmBlockErrorCounterErrorPortn | read-only | current | Remote Counter Error :This bit when set indicates the FEC corrected errors counter value is invalid on Line |
| 1.3.6.1.4.1.20044.76.4.3.194.1.4 | Columnpmo10010CntremoteLineSmBlockErrorCounterOverloadPortn | read-only | current | Remote Counter Overload :This bit when set indicates a FEC corrected errors counter overload on Line |
| 1.3.6.1.4.1.20044.76.4.3.195 | Tablepmo10010CntlineDfrmTimCntTable | not-accessible | current | List of pmo10010CntlineDfrmTimCnt Article |
| 1.3.6.1.4.1.20044.76.4.3.195.1 | Rowpmo10010CntlineDfrmTimCntEntry | not-accessible | current | Row definition for the pmo10010CntlineDfrmTimCnt table |
| 1.3.6.1.4.1.20044.76.4.3.195.1.1 | Columnpmo10010CntlineDfrmTimCntIndex | read-only | current | Index definition for the pmo10010CntlineDfrmTimCnt table |
| 1.3.6.1.4.1.20044.76.4.3.195.1.2 | Columnpmo10010CntlineDfrmTimCntValuePortn | read-only | current | Line Timer Counter : |
| 1.3.6.1.4.1.20044.76.4.3.195.1.3 | Columnpmo10010CntlineDfrmTimCntErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.76.4.3.195.1.4 | Columnpmo10010CntlineDfrmTimCntOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.76.4.3.196 | Tablepmo10010CntlocalLineTrscvFecCorrectedErrorCounterTable | not-accessible | current | List of pmo10010CntlocalLineTrscvFecCorrectedErrorCounter Article |
| 1.3.6.1.4.1.20044.76.4.3.196.1 | Rowpmo10010CntlocalLineTrscvFecCorrectedErrorCounterEntry | not-accessible | current | Row definition for the pmo10010CntlocalLineTrscvFecCorrectedErrorCounter table |
| 1.3.6.1.4.1.20044.76.4.3.196.1.1 | Columnpmo10010CntlocalLineTrscvFecCorrectedErrorCounterIndex | read-only | current | Index definition for the pmo10010CntlocalLineTrscvFecCorrectedErrorCounter table |
| 1.3.6.1.4.1.20044.76.4.3.196.1.2 | Columnpmo10010CntlocalLineTrscvFecCorrectedErrorCounterValuePortn | read-only | current | Line Input SD FEC Corrected Errors :This OID gives the current Bit Error Rate before the Soft Decision FEC <Help> This counter gives the current Bit Error Rate… |
| 1.3.6.1.4.1.20044.76.4.3.196.1.3 | Columnpmo10010CntlocalLineTrscvFecCorrectedErrorCounterErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.76.4.3.196.1.4 | Columnpmo10010CntlocalLineTrscvFecCorrectedErrorCounterOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.76.4.3.197 | Tablepmo10010CntlocalLineTrscvFecUncorrectedErrorCounterTable | not-accessible | current | List of pmo10010CntlocalLineTrscvFecUncorrectedErrorCounter Article |
| 1.3.6.1.4.1.20044.76.4.3.197.1 | Rowpmo10010CntlocalLineTrscvFecUncorrectedErrorCounterEntry | not-accessible | current | Row definition for the pmo10010CntlocalLineTrscvFecUncorrectedErrorCounter table |
| 1.3.6.1.4.1.20044.76.4.3.197.1.1 | Columnpmo10010CntlocalLineTrscvFecUncorrectedErrorCounterIndex | read-only | current | Index definition for the pmo10010CntlocalLineTrscvFecUncorrectedErrorCounter table |
| 1.3.6.1.4.1.20044.76.4.3.197.1.2 | Columnpmo10010CntlocalLineTrscvFecUncorrectedErrorCounterValuePortn | read-only | current | SD Uncorrected :This OID gives the current Bit Error Rate after the Soft Decision FEC (residual) <Help> This counter gives the current Bit Error Rate after the… |
| 1.3.6.1.4.1.20044.76.4.3.197.1.3 | Columnpmo10010CntlocalLineTrscvFecUncorrectedErrorCounterErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.76.4.3.197.1.4 | Columnpmo10010CntlocalLineTrscvFecUncorrectedErrorCounterOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.76.4.3.200 | Tablepmo10010CntlocalLinePmBlockErrorCounterTable | not-accessible | current | List of pmo10010CntlocalLinePmBlockErrorCounter Article |
| 1.3.6.1.4.1.20044.76.4.3.200.1 | Rowpmo10010CntlocalLinePmBlockErrorCounterEntry | not-accessible | current | Row definition for the pmo10010CntlocalLinePmBlockErrorCounter table |
| 1.3.6.1.4.1.20044.76.4.3.200.1.1 | Columnpmo10010CntlocalLinePmBlockErrorCounterIndex | read-only | current | Index definition for the pmo10010CntlocalLinePmBlockErrorCounter table |
| 1.3.6.1.4.1.20044.76.4.3.200.1.2 | Columnpmo10010CntlocalLinePmBlockErrorCounterValuePortn | read-only | current | Line Input PM Block Errors :This OID gives the PM B1 errors counted as block errors <Help> This counter gives the PM B1 errors counted as block errors |
| 1.3.6.1.4.1.20044.76.4.3.200.1.3 | Columnpmo10010CntlocalLinePmBlockErrorCounterErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.76.4.3.200.1.4 | Columnpmo10010CntlocalLinePmBlockErrorCounterOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.76.4.3.201 | Tablepmo10010CntremoteLinePmBlockErrorCounterTable | not-accessible | current | List of pmo10010CntremoteLinePmBlockErrorCounter Article |
| 1.3.6.1.4.1.20044.76.4.3.201.1 | Rowpmo10010CntremoteLinePmBlockErrorCounterEntry | not-accessible | current | Row definition for the pmo10010CntremoteLinePmBlockErrorCounter table |
| 1.3.6.1.4.1.20044.76.4.3.201.1.1 | Columnpmo10010CntremoteLinePmBlockErrorCounterIndex | read-only | current | Index definition for the pmo10010CntremoteLinePmBlockErrorCounter table |
| 1.3.6.1.4.1.20044.76.4.3.201.1.2 | Columnpmo10010CntremoteLinePmBlockErrorCounterValuePortn | read-only | current | Remote PM Block Errors :This OID gives the PM Remote Error Indication counted as block errorsPM Remote Error Indication counted as block errors |
| 1.3.6.1.4.1.20044.76.4.3.201.1.3 | Columnpmo10010CntremoteLinePmBlockErrorCounterErrorPortn | read-only | current | Remote Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.76.4.3.201.1.4 | Columnpmo10010CntremoteLinePmBlockErrorCounterOverloadPortn | read-only | current | Remote Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.76.6 | Nodepmo10010controlsWrite | |||
| 1.3.6.1.4.1.20044.76.6.1 | Nodepmo10010CtrlOther | |||
| 1.3.6.1.4.1.20044.76.6.1.1 | Nodepmo10010CtrlconfMgnt1 | |||
| 1.3.6.1.4.1.20044.76.6.1.1.1 | Scalarpmo10010CtrlConf1Load1 | read-write | current | Load Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM. |
| 1.3.6.1.4.1.20044.76.6.1.1.2 | Scalarpmo10010CtrlConf2Load1 | read-write | current | Load Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM. |
| 1.3.6.1.4.1.20044.76.6.1.1.10 | Scalarpmo10010CtrlConf2Flash1 | read-write | current | Write Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura… |
| 1.3.6.1.4.1.20044.76.6.1.1.14 | Scalarpmo10010CtrlConf2Clear1 | read-write | current | Clear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o… |
| 1.3.6.1.4.1.20044.76.6.1.4 | Nodepmo10010Ctrlsynth4 | |||
| 1.3.6.1.4.1.20044.76.6.1.4.1 | Scalarpmo10010CtrlCorrelatOn | read-write | current | Enable Alarm Correlation :This OID enables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.76.6.1.4.2 | Scalarpmo10010CtrlCorrelatOff | read-write | current | Disable Alarm Correlation :This OID disables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.76.6.1.5 | Nodepmo10010CtrlswMgnt | |||
| 1.3.6.1.4.1.20044.76.6.1.5.2 | Scalarpmo10010CtrlColdReset | read-write | current | PM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> … |
| 1.3.6.1.4.1.20044.76.6.1.5.3 | Scalarpmo10010CtrlWarmReset | read-write | current | PM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th… |
| 1.3.6.1.4.1.20044.76.6.1.5.5 | Scalarpmo10010CtrlLoadSwBank1 | read-write | current | Set Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW… |
| 1.3.6.1.4.1.20044.76.6.1.5.6 | Scalarpmo10010CtrlLoadSwBank2 | read-write | current | Set Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S… |
| 1.3.6.1.4.1.20044.76.6.1.6 | Nodepmo10010CtrlgwMgnt | |||
| 1.3.6.1.4.1.20044.76.6.1.6.1 | Scalarpmo10010CtrlCurrentGwReset | read-write | current | Active Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting. |
| 1.3.6.1.4.1.20044.76.6.1.6.5 | Scalarpmo10010CtrlLoadGwBank1 | read-write | current | Set Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.76.6.1.6.6 | Scalarpmo10010CtrlLoadGwBank2 | read-write | current | Set Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.76.6.1.6.7 | Scalarpmo10010CtrlLoadGwBank3 | read-write | current | Set Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.76.6.1.6.8 | Scalarpmo10010CtrlLoadGwBank4 | read-write | current | Set Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.76.6.1.192 | Nodepmo10010CtrlledTest | |||
| 1.3.6.1.4.1.20044.76.6.1.192.1 | Scalarpmo10010CtrlGreenLed | read-write | current | Green Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green |
| 1.3.6.1.4.1.20044.76.6.1.192.2 | Scalarpmo10010CtrlRedLed | read-write | current | Red Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red |
| 1.3.6.1.4.1.20044.76.6.1.192.3 | Scalarpmo10010CtrlLedOff | read-write | current | Leds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF |
| 1.3.6.1.4.1.20044.76.6.1.201 | Nodepmo10010CtrlinitSwitchMarvell | |||
| 1.3.6.1.4.1.20044.76.6.1.201.1 | Scalarpmo10010CtrlInitSwitchMarvell | read-write | current | Switch Initialization :This OID operates an initialization of the switch managed through the module <Help> This control activates an initialization of the swit… |
| 1.3.6.1.4.1.20044.76.6.1.259 | Nodepmo10010CtrlresetCount | |||
| 1.3.6.1.4.1.20044.76.6.1.259.1 | Scalarpmo10010CtrlResetcount | read-write | current | Module Count Global Reset :This OID resets all the errors counters on the module <Help > This control initiates a reset of the errors counters on the module |
| 1.3.6.1.4.1.20044.76.6.1.260 | Nodepmo10010CtrlresetRmon | |||
| 1.3.6.1.4.1.20044.76.6.1.260.1 | Scalarpmo10010CtrlResetrmon | read-write | current | Module Rmon Global Reset :This OID resets all the Rmon counters on the module <Help > This control initiates a reset of the Rmon counters on the module |
| 1.3.6.1.4.1.20044.76.6.1.261 | Nodepmo10010CtrlresetMeasurements | |||
| 1.3.6.1.4.1.20044.76.6.1.261.1 | Scalarpmo10010CtrlResetmeasurements | read-write | current | Management Meas Global Reset :This OID resets some measurements on the management <Help > This control initiates a reset of some measurements on the management |
| 1.3.6.1.4.1.20044.76.6.2 | Nodepmo10010CtrlClient | |||
| 1.3.6.1.4.1.20044.76.6.2.16 | Tablepmo10010CtrlaccessLoopTable | not-accessible | current | List of pmo10010CtrlaccessLoop Article |
| 1.3.6.1.4.1.20044.76.6.2.16.1 | Rowpmo10010CtrlaccessLoopEntry | not-accessible | current | Row definition for the pmo10010CtrlaccessLoop table |
| 1.3.6.1.4.1.20044.76.6.2.16.1.1 | Columnpmo10010CtrlaccessLoopIndex | read-only | current | Index definition for the pmo10010CtrlaccessLoop table |
| 1.3.6.1.4.1.20044.76.6.2.16.1.2 | Columnpmo10010CtrlaccessLoopPortn | read-write | current | Client Facility Loopback :This OID, when set at '1' puts the client port in loopback, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. <Help… |
| 1.3.6.1.4.1.20044.76.6.2.17 | Tablepmo10010CtrlclientLoopToLineTable | not-accessible | current | List of pmo10010CtrlclientLoopToLine Article |
| 1.3.6.1.4.1.20044.76.6.2.17.1 | Rowpmo10010CtrlclientLoopToLineEntry | not-accessible | current | Row definition for the pmo10010CtrlclientLoopToLine table |
| 1.3.6.1.4.1.20044.76.6.2.17.1.1 | Columnpmo10010CtrlclientLoopToLineIndex | read-only | current | Index definition for the pmo10010CtrlclientLoopToLine table |
| 1.3.6.1.4.1.20044.76.6.2.17.1.2 | Columnpmo10010CtrlclientLoopToLinePortn | read-write | current | Client Terminal Loopback :This OID, when set, puts the client port in loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.<Help> This control ena… |
| 1.3.6.1.4.1.20044.76.6.2.21 | Tablepmo10010CtrlcsfUpInsTable | not-accessible | current | List of pmo10010CtrlcsfUpIns Article |
| 1.3.6.1.4.1.20044.76.6.2.21.1 | Rowpmo10010CtrlcsfUpInsEntry | not-accessible | current | Row definition for the pmo10010CtrlcsfUpIns table |
| 1.3.6.1.4.1.20044.76.6.2.21.1.1 | Columnpmo10010CtrlcsfUpInsIndex | read-only | current | Index definition for the pmo10010CtrlcsfUpIns table |
| 1.3.6.1.4.1.20044.76.6.2.21.1.2 | Columnpmo10010CtrlcsfUpInsPortn | read-write | current | Client Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo… |
| 1.3.6.1.4.1.20044.76.6.2.22 | Tablepmo10010CtrlcaisDwInsTable | not-accessible | current | List of pmo10010CtrlcaisDwIns Article |
| 1.3.6.1.4.1.20044.76.6.2.22.1 | Rowpmo10010CtrlcaisDwInsEntry | not-accessible | current | Row definition for the pmo10010CtrlcaisDwIns table |
| 1.3.6.1.4.1.20044.76.6.2.22.1.1 | Columnpmo10010CtrlcaisDwInsIndex | read-only | current | Index definition for the pmo10010CtrlcaisDwIns table |
| 1.3.6.1.4.1.20044.76.6.2.22.1.2 | Columnpmo10010CtrlcaisDwInsPortn | read-write | current | Client AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port |
| 1.3.6.1.4.1.20044.76.6.3 | Nodepmo10010CtrlLine | |||
| 1.3.6.1.4.1.20044.76.6.3.64 | Tablepmo10010CtrlcommAccessLoopTable | not-accessible | current | List of pmo10010CtrlcommAccessLoop Article |
| 1.3.6.1.4.1.20044.76.6.3.64.1 | Rowpmo10010CtrlcommAccessLoopEntry | not-accessible | current | Row definition for the pmo10010CtrlcommAccessLoop table |
| 1.3.6.1.4.1.20044.76.6.3.64.1.1 | Columnpmo10010CtrlcommAccessLoopIndex | read-only | current | Index definition for the pmo10010CtrlcommAccessLoop table |
| 1.3.6.1.4.1.20044.76.6.3.64.1.2 | Columnpmo10010CtrlcommAccessLoopPortn | read-write | current | Line Terminal Loopback :This OID, when set, puts the module in common access loop back, looping the 100 Gb/s output signal on the 100 Gb/s input.<Help> This co… |
| 1.3.6.1.4.1.20044.76.6.3.66 | Tablepmo10010CtrllineLoopTable | not-accessible | current | List of pmo10010CtrllineLoop Article |
| 1.3.6.1.4.1.20044.76.6.3.66.1 | Rowpmo10010CtrllineLoopEntry | not-accessible | current | Row definition for the pmo10010CtrllineLoop table |
| 1.3.6.1.4.1.20044.76.6.3.66.1.1 | Columnpmo10010CtrllineLoopIndex | read-only | current | Index definition for the pmo10010CtrllineLoop table |
| 1.3.6.1.4.1.20044.76.6.3.66.1.2 | Columnpmo10010CtrllineLoopPortn | read-write | current | Line Facility Loopback :This OID, when set at '1' puts the module in line loopback mode, looping the received 100 Gb/s signal on the transmit 100 Gb/s output. … |
| 1.3.6.1.4.1.20044.76.6.3.69 | Tablepmo10010CtrlfecDisableTable | not-accessible | current | List of pmo10010CtrlfecDisable Article |
| 1.3.6.1.4.1.20044.76.6.3.69.1 | Rowpmo10010CtrlfecDisableEntry | not-accessible | current | Row definition for the pmo10010CtrlfecDisable table |
| 1.3.6.1.4.1.20044.76.6.3.69.1.1 | Columnpmo10010CtrlfecDisableIndex | read-only | current | Index definition for the pmo10010CtrlfecDisable table |
| 1.3.6.1.4.1.20044.76.6.3.69.1.2 | Columnpmo10010CtrlfecDisablePortn | read-write | current | Forward Error Correction Inhibition :This OID, when set, inhibits the Forward Error Correction feature on the line input <Help> This control enables/disables t… |
| 1.3.6.1.4.1.20044.76.6.3.209 | Tablepmo10010CtrlmsaLineLoopTable | not-accessible | current | List of pmo10010CtrlmsaLineLoop Article |
| 1.3.6.1.4.1.20044.76.6.3.209.1 | Rowpmo10010CtrlmsaLineLoopEntry | not-accessible | current | Row definition for the pmo10010CtrlmsaLineLoop table |
| 1.3.6.1.4.1.20044.76.6.3.209.1.1 | Columnpmo10010CtrlmsaLineLoopIndex | read-only | current | Index definition for the pmo10010CtrlmsaLineLoop table |
| 1.3.6.1.4.1.20044.76.6.3.209.1.2 | Columnpmo10010CtrlmsaLineLoopPortn | read-write | current | MSA Line Loop :This OID operates a line loopback on the MSA Line <Help> This control defines the line loop back of the line transceiver |
| 1.3.6.1.4.1.20044.76.6.3.210 | Tablepmo10010CtrlmsaTxResetTable | not-accessible | current | List of pmo10010CtrlmsaTxReset Article |
| 1.3.6.1.4.1.20044.76.6.3.210.1 | Rowpmo10010CtrlmsaTxResetEntry | not-accessible | current | Row definition for the pmo10010CtrlmsaTxReset table |
| 1.3.6.1.4.1.20044.76.6.3.210.1.1 | Columnpmo10010CtrlmsaTxResetIndex | read-only | current | Index definition for the pmo10010CtrlmsaTxReset table |
| 1.3.6.1.4.1.20044.76.6.3.210.1.2 | Columnpmo10010CtrlmsaTxResetPortn | read-write | current | Line MSA TX Reset :This OID resets the TX portion of the MSA line module <Help > This control initiates a reset of the transmitting side |
| 1.3.6.1.4.1.20044.76.6.3.211 | Tablepmo10010CtrlmsaRxResetTable | not-accessible | current | List of pmo10010CtrlmsaRxReset Article |
| 1.3.6.1.4.1.20044.76.6.3.211.1 | Rowpmo10010CtrlmsaRxResetEntry | not-accessible | current | Row definition for the pmo10010CtrlmsaRxReset table |
| 1.3.6.1.4.1.20044.76.6.3.211.1.1 | Columnpmo10010CtrlmsaRxResetIndex | read-only | current | Index definition for the pmo10010CtrlmsaRxReset table |
| 1.3.6.1.4.1.20044.76.6.3.211.1.2 | Columnpmo10010CtrlmsaRxResetPortn | read-write | current | Line MSA RX Reset :This OID resets the RX portion of the MSA line module <Help > This control initiates a reset of the receiving side |
| 1.3.6.1.4.1.20044.76.6.3.212 | Tablepmo10010CtrlmsaShutdownTable | not-accessible | current | List of pmo10010CtrlmsaShutdown Article |
| 1.3.6.1.4.1.20044.76.6.3.212.1 | Rowpmo10010CtrlmsaShutdownEntry | not-accessible | current | Row definition for the pmo10010CtrlmsaShutdown table |
| 1.3.6.1.4.1.20044.76.6.3.212.1.1 | Columnpmo10010CtrlmsaShutdownIndex | read-only | current | Index definition for the pmo10010CtrlmsaShutdown table |
| 1.3.6.1.4.1.20044.76.6.3.212.1.2 | Columnpmo10010CtrlmsaShutdownPortn | read-write | current | Line MSA Shutdown :This OID enters a process to shutdown the MSA line module <Help > This control initiates a shutdown of the module |
| 1.3.6.1.4.1.20044.76.7 | Nodepmo10010ri | |||
| 1.3.6.1.4.1.20044.76.7.1 | Nodepmo10010riTable | |||
| 1.3.6.1.4.1.20044.76.7.1.1 | Tablepmo10010RinvSfpTable | not-accessible | current | List of the SFPs on the selected module |
| 1.3.6.1.4.1.20044.76.7.1.1.1 | Rowpmo10010RinvSfpEntry | not-accessible | current | Row definition for the SFP table |
| 1.3.6.1.4.1.20044.76.7.1.1.1.1 | Columnpmo10010RinvSfpIndex | read-only | current | Index for SFP table |
| 1.3.6.1.4.1.20044.76.7.1.1.1.2 | Columnpmo10010Rinvsfp | read-only | current | Inventory for the SFP: This OID contains the inventory for the SFP |
| 1.3.6.1.4.1.20044.76.7.1.2 | Tablepmo10010RinvLineTable | not-accessible | current | List of the XFPs on the selected module |
| 1.3.6.1.4.1.20044.76.7.1.2.1 | Rowpmo10010RinvLineEntry | not-accessible | current | Row definition for the XFP table |
| 1.3.6.1.4.1.20044.76.7.1.2.1.1 | Columnpmo10010RinvLineIndex | read-only | current | Index for XFP table |
| 1.3.6.1.4.1.20044.76.7.1.2.1.2 | Columnpmo10010RinvxfpLine | read-only | current | Inventory for the XFP: This OID contains the inventory for the XFP |
| 1.3.6.1.4.1.20044.76.7.2 | Scalarpmo10010RinvReloadInventory | read-write | current | Reload the inventory: This OID triggers an inventory reload. |
| 1.3.6.1.4.1.20044.76.7.3 | Scalarpmo10010RinvHwPlatform | read-only | current | HW platform description: This OID contains the description of the Hardware platform. |
| 1.3.6.1.4.1.20044.76.7.4 | Scalarpmo10010RinvModulePlatform | read-only | current | Module platform description: This OID contains the description of the Module. |
| 1.3.6.1.4.1.20044.76.7.5 | Scalarpmo10010RinvSwPlatform | read-only | current | SW platform description: This OID contains the description of the Software platform. |
| 1.3.6.1.4.1.20044.76.7.6 | Scalarpmo10010RinvGwPlatform | read-only | current | GW platform desciption: This OID contains the description of the Gateware platform. |
| 1.3.6.1.4.1.20044.76.8 | Nodepmo10010download | |||
| 1.3.6.1.4.1.20044.76.8.1 | Nodepmo10010DwlOther | |||
| 1.3.6.1.4.1.20044.76.8.1.0 | Nodepmo10010DwlrestartProcess | |||
| 1.3.6.1.4.1.20044.76.8.1.0.1 | Scalarpmo10010DwlWarmRestartProcessed | read-only | current | Warm Restart :This OID indicates that the module last restart was a Warm RESTART |
| 1.3.6.1.4.1.20044.76.8.1.0.2 | Scalarpmo10010DwlColdRestartProcessed | read-only | current | Cold Restart :This OID indicates that the module last restart was a Cold RESTART |
| 1.3.6.1.4.1.20044.76.8.1.1 | Nodepmo10010DwlswBanksUsed | |||
| 1.3.6.1.4.1.20044.76.8.1.1.1 | Scalarpmo10010DwlSwBank1Used | read-only | current | SW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.76.8.1.1.2 | Scalarpmo10010DwlSwBank2Used | read-only | current | SW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby |
| 1.3.6.1.4.1.20044.76.8.1.1.5 | Scalarpmo10010DwlSwBank1Notempty | read-only | current | SW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package |
| 1.3.6.1.4.1.20044.76.8.1.1.6 | Scalarpmo10010DwlSwBank2Notempty | read-only | current | SW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package |
| 1.3.6.1.4.1.20044.76.8.1.2 | Nodepmo10010DwlgwBanksUsed | |||
| 1.3.6.1.4.1.20044.76.8.1.2.1 | Scalarpmo10010DwlGwBank1Used | read-only | current | GW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.76.8.1.2.2 | Scalarpmo10010DwlGwBank2Used | read-only | current | GW bank 2 active :This OID indicates the module is working on GW bank 2 |
| 1.3.6.1.4.1.20044.76.8.1.2.3 | Scalarpmo10010DwlGwBank3Used | read-only | current | GW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby |
| 1.3.6.1.4.1.20044.76.8.1.2.4 | Scalarpmo10010DwlGwBank4Used | read-only | current | GW bank 4 active :This OID indicates the module is working on GW bank 4 |
| 1.3.6.1.4.1.20044.76.8.1.2.5 | Scalarpmo10010DwlGwBank1Notempty | read-only | current | GW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package |
| 1.3.6.1.4.1.20044.76.8.1.2.6 | Scalarpmo10010DwlGwBank2Notempty | read-only | current | GW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2 |
| 1.3.6.1.4.1.20044.76.8.1.2.7 | Scalarpmo10010DwlGwBank3Notempty | read-only | current | GW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package |
| 1.3.6.1.4.1.20044.76.8.1.2.8 | Scalarpmo10010DwlGwBank4Notempty | read-only | current | GW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4 |
| 1.3.6.1.4.1.20044.76.8.2 | Nodepmo10010DwlClient | |||
| 1.3.6.1.4.1.20044.76.8.3 | Nodepmo10010DwlLine | |||
| 1.3.6.1.4.1.20044.76.9 | Nodepmo10010Config | |||
| 1.3.6.1.4.1.20044.76.9.1 | Nodepmo10010CfgAccessCAisCsf | |||
| 1.3.6.1.4.1.20044.76.9.1.1 | Tablepmo10010CfgClientcaiscsfTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.76.9.1.1.1 | Rowpmo10010CfgClientcaiscsfEntry | not-accessible | current | Row definition for the accessCAisCsf table |
| 1.3.6.1.4.1.20044.76.9.1.1.1.1 | Columnpmo10010CfgClientcaiscsfIndex | read-only | current | Index definition for the clientcaiscsf table |
| 1.3.6.1.4.1.20044.76.9.1.1.1.3 | Columnpmo10010CfgReservePortn | read-write | current | CAIS mode on Client Port :This register enables/disables port laser shutdown on CAIS insertion condition |
| 1.3.6.1.4.1.20044.76.9.2 | Nodepmo10010CfgStartup | |||
| 1.3.6.1.4.1.20044.76.9.2.1 | Tablepmo10010CfgClientStartupTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.76.9.2.1.1 | Rowpmo10010CfgClientStartupEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.76.9.2.1.1.1 | Columnpmo10010CfgClientStartupIndex | read-only | current | Index definition for the clientStartup table |
| 1.3.6.1.4.1.20044.76.9.2.1.1.3 | Columnpmo10010CfgSystConfPortPortn | read-write | current | Default Settings on Client Port :This register configures the default initialisation settings on the port. |
| 1.3.6.1.4.1.20044.76.9.2.1.1.4 | Columnpmo10010CfgNetConfPortPortn | read-write | current | Default Settings on Client Port :This register configures the default initialisation settings on the port. |
| 1.3.6.1.4.1.20044.76.9.2.1.1.14 | Columnpmo10010CfgOptionsPortPortn | read-write | current | Default Options on Client Port :This register configures the default options on the port. |
| 1.3.6.1.4.1.20044.76.9.2.2 | Tablepmo10010CfgLineStartupTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.76.9.2.2.1 | Rowpmo10010CfgLineStartupEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.76.9.2.2.1.1 | Columnpmo10010CfgLineStartupIndex | read-only | current | Index definition for the lineStartup table |
| 1.3.6.1.4.1.20044.76.9.2.2.1.3 | Columnpmo10010CfgSystConfLinePortn | read-write | current | Default Settings on Line :This register configures the default initialisation settings on Line |
| 1.3.6.1.4.1.20044.76.9.2.2.1.14 | Columnpmo10010CfgOptionsLinePortn | read-write | current | Default Options on Line :This register configures the default options on the line |
| 1.3.6.1.4.1.20044.76.9.2.3 | Tablepmo10010CfgXfpTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.76.9.2.3.1 | Rowpmo10010CfgXfpEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.76.9.2.3.1.1 | Columnpmo10010CfgXfpIndex | read-only | current | Index definition for the xfp table |
| 1.3.6.1.4.1.20044.76.9.2.3.1.3 | Columnpmo10010CfgSystConfMsaLinePortn | read-write | current | Default settings on MSA :This register configures the default initialisation settings on MSA |
| 1.3.6.1.4.1.20044.76.9.2.4 | Tablepmo10010CfgClientOtxtlhTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.76.9.2.4.1 | Rowpmo10010CfgClientOtxtlhEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.76.9.2.4.1.1 | Columnpmo10010CfgClientOtxtlhIndex | read-only | current | Index definition for the clientOtxtlh table |
| 1.3.6.1.4.1.20044.76.9.2.4.1.3 | Columnpmo10010CfgControlsPortn | read-write | deprecated | Defaut Client settings :This register configures the start-up settings on the ports |
| 1.3.6.1.4.1.20044.76.9.2.4.1.6 | Columnpmo10010CfgClientPwrLaserPortn | read-write | current | Defaut Client output Power :This register configures the start-up output power of the client transceiver (Unit = dBm) |
| 1.3.6.1.4.1.20044.76.9.2.4.1.7 | Columnpmo10010CfgClientFCurrentPortn | read-write | current | Default Client transceiver Channel :This register configures the start-up laser channel of the client transceiver |
| 1.3.6.1.4.1.20044.76.9.2.4.1.8 | Columnpmo10010CfgClientGridCurrentPortn | read-write | current | Default Client transceiver Grid :This register configures the start-up laser grid of the client transceiver |
| 1.3.6.1.4.1.20044.76.9.2.4.1.9 | Columnpmo10010CfgClientFoPortn | read-write | current | Default Client first Frequency :This register configures the start-up first frequency of the client transceiver |
| 1.3.6.1.4.1.20044.76.9.3 | Nodepmo10010CfgLabels | |||
| 1.3.6.1.4.1.20044.76.9.3.1 | Tablepmo10010CfgLabelclientTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.76.9.3.1.1 | Rowpmo10010CfgLabelclientEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.76.9.3.1.1.1 | Columnpmo10010CfgLabelclientIndex | read-only | current | Index definition for the labelclient table |
| 1.3.6.1.4.1.20044.76.9.3.1.1.3 | Columnpmo10010CfgLabelclientPortn | read-write | current | Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. |
| 1.3.6.1.4.1.20044.76.9.3.2 | Tablepmo10010CfgLabellineTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.76.9.3.2.1 | Rowpmo10010CfgLabellineEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.76.9.3.2.1.1 | Columnpmo10010CfgLabellineIndex | read-only | current | Index definition for the labelline table |
| 1.3.6.1.4.1.20044.76.9.3.2.1.3 | Columnpmo10010CfgLabellinePortn | read-write | current | Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. |
| 1.3.6.1.4.1.20044.76.9.4 | Nodepmo10010CfgStartuptlh | |||
| 1.3.6.1.4.1.20044.76.9.4.1 | Tablepmo10010CfgOtxtlhTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.76.9.4.1.1 | Rowpmo10010CfgOtxtlhEntry | not-accessible | current | Row definition for the startuptlh table |
| 1.3.6.1.4.1.20044.76.9.4.1.1.1 | Columnpmo10010CfgOtxtlhIndex | read-only | current | Index definition for the otxtlh table |
| 1.3.6.1.4.1.20044.76.9.4.1.1.6 | Columnpmo10010CfgLinePwrLaserPortn | read-write | current | Defaut Line output Power :This register configures the start-up output power of the Line tranceiver (Unit = dBm) |
| 1.3.6.1.4.1.20044.76.9.4.1.1.7 | Columnpmo10010CfgLineFCurrentPortn | read-write | current | Default Line transceiver Tx Channel :This register configures the start-up laser channel of the Line Tx transceiver |
| 1.3.6.1.4.1.20044.76.9.4.1.1.8 | Columnpmo10010CfgLineGridCurrentPortn | read-write | current | Default Line transceiver Grid :This register configures the start-up laser grid of the Line transceiver |
| 1.3.6.1.4.1.20044.76.9.4.1.1.9 | Columnpmo10010CfgFPortn | read-write | current | Default Line TRX lowest Freq :This register configures the start-up lowest frequency of the Line transceiver |
| 1.3.6.1.4.1.20044.76.9.4.1.1.10 | Columnpmo10010CfgRxLineFCurrentPortn | read-write | current | Default Line transceiver Rx Channel :This register configures the start-up laser channel of the Line Rx transceiver |
| 1.3.6.1.4.1.20044.76.9.5 | Nodepmo10010CfgOther | |||
| 1.3.6.1.4.1.20044.76.9.5.1 | Nodepmo10010tablemoduleOther | |||
| 1.3.6.1.4.1.20044.76.9.5.1.2 | Scalarpmo10010Cfgmode | read-write | current | Default settings on Module :This register selects the configuration mode of the module |
| 1.3.6.1.4.1.20044.76.9.5.1.3 | Scalarpmo10010CfgfanLowSpeedThreshold | read-write | current | Default settings on Module :This register selects the speed threshold of the fan's |
| 1.3.6.1.4.1.20044.76.9.5.1.4 | Scalarpmo10010CfgfanHighSpeedThreshold | read-write | current | Default settings on Module :This register selects the speed threshold of the fan's |
| 1.3.6.1.4.1.20044.76.9.6 | Nodepmo10010CfgOdu2Clienta | |||
| 1.3.6.1.4.1.20044.76.9.6.1 | Tablepmo10010CfgClientStartupOduTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.76.9.6.1.1 | Rowpmo10010CfgClientStartupOduEntry | not-accessible | current | Row definition for the odu2Clienta table |
| 1.3.6.1.4.1.20044.76.9.6.1.1.1 | Columnpmo10010CfgClientStartupOduIndex | read-only | current | Index definition for the clientStartupOdu table |
| 1.3.6.1.4.1.20044.76.9.6.1.1.3 | Columnpmo10010CfgOdu2ReserveLsbPortn | read-write | current | : |
| 1.3.6.1.4.1.20044.76.9.6.1.1.4 | Columnpmo10010CfgOdu2DegthresholdMsbPortn | read-write | current | ODU2 Degrade Threshold : |
| 1.3.6.1.4.1.20044.76.9.6.1.1.5 | Columnpmo10010CfgOdu2DegmPortn | read-write | current | ODU2 Degrade Confirmation : |
| 1.3.6.1.4.1.20044.76.9.6.1.1.6 | Columnpmo10010CfgOdu2SettingsPortn | read-write | current | ODU2 Settings : |
| 1.3.6.1.4.1.20044.76.9.7 | Nodepmo10010CfgOtu4Line | |||
| 1.3.6.1.4.1.20044.76.9.7.1 | Tablepmo10010CfgLinexStartupOtuTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.76.9.7.1.1 | Rowpmo10010CfgLinexStartupOtuEntry | not-accessible | current | Row definition for the otu4Line table |
| 1.3.6.1.4.1.20044.76.9.7.1.1.1 | Columnpmo10010CfgLinexStartupOtuIndex | read-only | current | Index definition for the linexStartupOtu table |
| 1.3.6.1.4.1.20044.76.9.7.1.1.3 | Columnpmo10010CfgOtu4ReserveLsbPortn | read-write | current | : |
| 1.3.6.1.4.1.20044.76.9.7.1.1.4 | Columnpmo10010CfgOtu4DegthresholdMsbPortn | read-write | current | OTU4 Degrade Threshold : |
| 1.3.6.1.4.1.20044.76.9.7.1.1.5 | Columnpmo10010CfgOtu4DegmPortn | read-write | current | OTU4 Degrade Confirmation : |
| 1.3.6.1.4.1.20044.76.9.7.1.1.6 | Columnpmo10010CfgOtu4SettingsPortn | read-write | current | OTU4 Settings : |
| 1.3.6.1.4.1.20044.76.9.8 | Nodepmo10010CfgOdu4Line | |||
| 1.3.6.1.4.1.20044.76.9.8.1 | Tablepmo10010CfgLinexStartupOduTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.76.9.8.1.1 | Rowpmo10010CfgLinexStartupOduEntry | not-accessible | current | Row definition for the odu4Line table |
| 1.3.6.1.4.1.20044.76.9.8.1.1.1 | Columnpmo10010CfgLinexStartupOduIndex | read-only | current | Index definition for the linexStartupOdu table |
| 1.3.6.1.4.1.20044.76.9.8.1.1.3 | Columnpmo10010CfgOdu4ReserveLsbPortn | read-write | current | : |
| 1.3.6.1.4.1.20044.76.9.8.1.1.4 | Columnpmo10010CfgOdu4DegthresholdMsbPortn | read-write | current | ODU4 Degrade Threshold : |
| 1.3.6.1.4.1.20044.76.9.8.1.1.5 | Columnpmo10010CfgOdu4DegmPortn | read-write | current | ODU4 Degrade Confirmation : |
| 1.3.6.1.4.1.20044.76.9.8.1.1.6 | Columnpmo10010CfgOdu4SettingsPortn | read-write | current | ODU4 Settings : |
| 1.3.6.1.4.1.20044.76.9.9 | Nodepmo10010CfgSapiTxClient | |||
| 1.3.6.1.4.1.20044.76.9.9.1 | Tablepmo10010CfgClientSapiTxOduTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.76.9.9.1.1 | Rowpmo10010CfgClientSapiTxOduEntry | not-accessible | current | Row definition for the sapiTxClient table |
| 1.3.6.1.4.1.20044.76.9.9.1.1.1 | Columnpmo10010CfgClientSapiTxOduIndex | read-only | current | Index definition for the clientSapiTxOdu table |
| 1.3.6.1.4.1.20044.76.9.9.1.1.3 | Columnpmo10010CfgClientSapiTxSetupPortn | read-write | current | Client Transmitted SAPI :This register defines the value of the transmitted Trace Identifier on the line output |
| 1.3.6.1.4.1.20044.76.9.10 | Nodepmo10010CfgSapiExpClient | |||
| 1.3.6.1.4.1.20044.76.9.10.1 | Tablepmo10010CfgClientSapiExpOduTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.76.9.10.1.1 | Rowpmo10010CfgClientSapiExpOduEntry | not-accessible | current | Row definition for the sapiExpClient table |
| 1.3.6.1.4.1.20044.76.9.10.1.1.1 | Columnpmo10010CfgClientSapiExpOduIndex | read-only | current | Index definition for the clientSapiExpOdu table |
| 1.3.6.1.4.1.20044.76.9.10.1.1.3 | Columnpmo10010CfgClientSapiExpSetupPortn | read-write | current | Client Expected SAPI :This register defines the value of the expected Trace Identifier on the line input |
| 1.3.6.1.4.1.20044.76.9.11 | Nodepmo10010CfgSapiAccClient | |||
| 1.3.6.1.4.1.20044.76.9.11.1 | Tablepmo10010CfgClientSapiAccOduTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.76.9.11.1.1 | Rowpmo10010CfgClientSapiAccOduEntry | not-accessible | current | Row definition for the sapiAccClient table |
| 1.3.6.1.4.1.20044.76.9.11.1.1.1 | Columnpmo10010CfgClientSapiAccOduIndex | read-only | current | Index definition for the clientSapiAccOdu table |
| 1.3.6.1.4.1.20044.76.9.11.1.1.3 | Columnpmo10010CfgClientSapiAccSetupPortn | read-write | deprecated | Client Accepted SAPI :This register defines the value of the accepted Trace Identifier on the line input |
| 1.3.6.1.4.1.20044.76.9.12 | Nodepmo10010CfgDapiTxClient | |||
| 1.3.6.1.4.1.20044.76.9.12.1 | Tablepmo10010CfgClientDapiTxOduTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.76.9.12.1.1 | Rowpmo10010CfgClientDapiTxOduEntry | not-accessible | current | Row definition for the dapiTxClient table |
| 1.3.6.1.4.1.20044.76.9.12.1.1.1 | Columnpmo10010CfgClientDapiTxOduIndex | read-only | current | Index definition for the clientDapiTxOdu table |
| 1.3.6.1.4.1.20044.76.9.12.1.1.3 | Columnpmo10010CfgClientDapiTxSetupPortn | read-write | current | Client Transmitted DAPI :This register defines the value of the transmitted Trace Identifier on the line output |
| 1.3.6.1.4.1.20044.76.9.13 | Nodepmo10010CfgDapiExpClient | |||
| 1.3.6.1.4.1.20044.76.9.13.1 | Tablepmo10010CfgClientDapiExpOduTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.76.9.13.1.1 | Rowpmo10010CfgClientDapiExpOduEntry | not-accessible | current | Row definition for the dapiExpClient table |
| 1.3.6.1.4.1.20044.76.9.13.1.1.1 | Columnpmo10010CfgClientDapiExpOduIndex | read-only | current | Index definition for the clientDapiExpOdu table |
| 1.3.6.1.4.1.20044.76.9.13.1.1.3 | Columnpmo10010CfgClientDapiExpSetupPortn | read-write | current | Client Expected DAPI :This register defines the value of the expected Trace Identifier on the line input |
| 1.3.6.1.4.1.20044.76.9.14 | Nodepmo10010CfgDapiAccClient | |||
| 1.3.6.1.4.1.20044.76.9.14.1 | Tablepmo10010CfgClientDapiAccOduTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.76.9.14.1.1 | Rowpmo10010CfgClientDapiAccOduEntry | not-accessible | current | Row definition for the dapiAccClient table |
| 1.3.6.1.4.1.20044.76.9.14.1.1.1 | Columnpmo10010CfgClientDapiAccOduIndex | read-only | current | Index definition for the clientDapiAccOdu table |
| 1.3.6.1.4.1.20044.76.9.14.1.1.3 | Columnpmo10010CfgClientDapiAccSetupPortn | read-write | deprecated | Client Accepted DAPI :This register defines the value of the accepted Trace Identifier on the line input |
| 1.3.6.1.4.1.20044.76.9.15 | Nodepmo10010CfgSapiTxLineOtu4 | |||
| 1.3.6.1.4.1.20044.76.9.15.1 | Tablepmo10010CfgLineSapiTxOtuTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.76.9.15.1.1 | Rowpmo10010CfgLineSapiTxOtuEntry | not-accessible | current | Row definition for the sapiTxLineOtu4 table |
| 1.3.6.1.4.1.20044.76.9.15.1.1.1 | Columnpmo10010CfgLineSapiTxOtuIndex | read-only | current | Index definition for the lineSapiTxOtu table |
| 1.3.6.1.4.1.20044.76.9.15.1.1.3 | Columnpmo10010CfgLineSapiTxSetupOtuPortn | read-write | current | OTU4 Line Transmitted SAPI :This register defines the value of the transmitted Trace Identifier on the line output |
| 1.3.6.1.4.1.20044.76.9.16 | Nodepmo10010CfgSapiExpLineOtu4 | |||
| 1.3.6.1.4.1.20044.76.9.16.1 | Tablepmo10010CfgLineSapiExpOtuTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.76.9.16.1.1 | Rowpmo10010CfgLineSapiExpOtuEntry | not-accessible | current | Row definition for the sapiExpLineOtu4 table |
| 1.3.6.1.4.1.20044.76.9.16.1.1.1 | Columnpmo10010CfgLineSapiExpOtuIndex | read-only | current | Index definition for the lineSapiExpOtu table |
| 1.3.6.1.4.1.20044.76.9.16.1.1.3 | Columnpmo10010CfgLineSapiExpSetupOtuPortn | read-write | current | OTU4 Line Expected SAPI :This register defines the value of the expected Trace Identifier on the line input |
| 1.3.6.1.4.1.20044.76.9.17 | Nodepmo10010CfgSapiAccLineOtu4 | |||
| 1.3.6.1.4.1.20044.76.9.17.1 | Tablepmo10010CfgLineSapiAccOtuTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.76.9.17.1.1 | Rowpmo10010CfgLineSapiAccOtuEntry | not-accessible | current | Row definition for the sapiAccLineOtu4 table |
| 1.3.6.1.4.1.20044.76.9.17.1.1.1 | Columnpmo10010CfgLineSapiAccOtuIndex | read-only | current | Index definition for the lineSapiAccOtu table |
| 1.3.6.1.4.1.20044.76.9.17.1.1.3 | Columnpmo10010CfgLineSapiAccSetupOtuPortn | read-write | deprecated | OTU4 Line Accepted SAPI :This register defines the value of the accepted Trace Identifier on the line input |
| 1.3.6.1.4.1.20044.76.9.18 | Nodepmo10010CfgDapiTxLineOtu4 | |||
| 1.3.6.1.4.1.20044.76.9.18.1 | Tablepmo10010CfgLineDapiTxOtuTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.76.9.18.1.1 | Rowpmo10010CfgLineDapiTxOtuEntry | not-accessible | current | Row definition for the dapiTxLineOtu4 table |
| 1.3.6.1.4.1.20044.76.9.18.1.1.1 | Columnpmo10010CfgLineDapiTxOtuIndex | read-only | current | Index definition for the lineDapiTxOtu table |
| 1.3.6.1.4.1.20044.76.9.18.1.1.3 | Columnpmo10010CfgLineDapiTxSetupOtuPortn | read-write | current | OTU4 Line Transmitted DAPI :This register defines the value of the transmitted Trace Identifier on the line output |
| 1.3.6.1.4.1.20044.76.9.19 | Nodepmo10010CfgDapiExpLineOtu4 | |||
| 1.3.6.1.4.1.20044.76.9.19.1 | Tablepmo10010CfgLineDapiExpOtuTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.76.9.19.1.1 | Rowpmo10010CfgLineDapiExpOtuEntry | not-accessible | current | Row definition for the dapiExpLineOtu4 table |
| 1.3.6.1.4.1.20044.76.9.19.1.1.1 | Columnpmo10010CfgLineDapiExpOtuIndex | read-only | current | Index definition for the lineDapiExpOtu table |
| 1.3.6.1.4.1.20044.76.9.19.1.1.3 | Columnpmo10010CfgLineDapiExpSetupOtuPortn | read-write | current | OTU4 Line Expected DAPI :This register defines the value of the expected Trace Identifier on the line input |
| 1.3.6.1.4.1.20044.76.9.20 | Nodepmo10010CfgDapiAccLineOtu4 | |||
| 1.3.6.1.4.1.20044.76.9.20.1 | Tablepmo10010CfgLineDapiAccOtuTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.76.9.20.1.1 | Rowpmo10010CfgLineDapiAccOtuEntry | not-accessible | current | Row definition for the dapiAccLineOtu4 table |
| 1.3.6.1.4.1.20044.76.9.20.1.1.1 | Columnpmo10010CfgLineDapiAccOtuIndex | read-only | current | Index definition for the lineDapiAccOtu table |
| 1.3.6.1.4.1.20044.76.9.20.1.1.3 | Columnpmo10010CfgLineDapiAccSetupOtuPortn | read-write | deprecated | OTU4 Line Accepted DAPI :This register defines the value of the accepted Trace Identifier on the line input |
| 1.3.6.1.4.1.20044.76.9.21 | Nodepmo10010CfgSapiTxLineOdu4 | |||
| 1.3.6.1.4.1.20044.76.9.21.1 | Tablepmo10010CfgLineSapiTxOduTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.76.9.21.1.1 | Rowpmo10010CfgLineSapiTxOduEntry | not-accessible | current | Row definition for the sapiTxLineOdu4 table |
| 1.3.6.1.4.1.20044.76.9.21.1.1.1 | Columnpmo10010CfgLineSapiTxOduIndex | read-only | current | Index definition for the lineSapiTxOdu table |
| 1.3.6.1.4.1.20044.76.9.21.1.1.3 | Columnpmo10010CfgLineSapiTxSetupOduPortn | read-write | current | ODU4 Line Transmitted SAPI :This register defines the value of the transmitted Trace Identifier on the line output |
| 1.3.6.1.4.1.20044.76.9.22 | Nodepmo10010CfgSapiExpLineOdu4 | |||
| 1.3.6.1.4.1.20044.76.9.22.1 | Tablepmo10010CfgLineSapiExpOduTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.76.9.22.1.1 | Rowpmo10010CfgLineSapiExpOduEntry | not-accessible | current | Row definition for the sapiExpLineOdu4 table |
| 1.3.6.1.4.1.20044.76.9.22.1.1.1 | Columnpmo10010CfgLineSapiExpOduIndex | read-only | current | Index definition for the lineSapiExpOdu table |
| 1.3.6.1.4.1.20044.76.9.22.1.1.3 | Columnpmo10010CfgLineSapiExpSetupOduPortn | read-write | current | ODU4 Line Expected SAPI :This register defines the value of the expected Trace Identifier on the line input |
| 1.3.6.1.4.1.20044.76.9.23 | Nodepmo10010CfgSapiAccLineOdu4 | |||
| 1.3.6.1.4.1.20044.76.9.23.1 | Tablepmo10010CfgLineSapiAccOduTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.76.9.23.1.1 | Rowpmo10010CfgLineSapiAccOduEntry | not-accessible | current | Row definition for the sapiAccLineOdu4 table |
| 1.3.6.1.4.1.20044.76.9.23.1.1.1 | Columnpmo10010CfgLineSapiAccOduIndex | read-only | current | Index definition for the lineSapiAccOdu table |
| 1.3.6.1.4.1.20044.76.9.23.1.1.3 | Columnpmo10010CfgLineSapiAccSetupOduPortn | read-write | deprecated | ODU4 Line Accepted SAPI :This register defines the value of the accepted Trace Identifier on the line input |
| 1.3.6.1.4.1.20044.76.9.24 | Nodepmo10010CfgDapiTxLineOdu4 | |||
| 1.3.6.1.4.1.20044.76.9.24.1 | Tablepmo10010CfgLineDapiTxOduTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.76.9.24.1.1 | Rowpmo10010CfgLineDapiTxOduEntry | not-accessible | current | Row definition for the dapiTxLineOdu4 table |
| 1.3.6.1.4.1.20044.76.9.24.1.1.1 | Columnpmo10010CfgLineDapiTxOduIndex | read-only | current | Index definition for the lineDapiTxOdu table |
| 1.3.6.1.4.1.20044.76.9.24.1.1.3 | Columnpmo10010CfgLineDapiTxSetupOduPortn | read-write | current | ODU4 Line Transmitted DAPI :This register defines the value of the transmitted Trace Identifier on the line output |
| 1.3.6.1.4.1.20044.76.9.25 | Nodepmo10010CfgDapiExpLineOdu4 | |||
| 1.3.6.1.4.1.20044.76.9.25.1 | Tablepmo10010CfgLineDapiExpOduTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.76.9.25.1.1 | Rowpmo10010CfgLineDapiExpOduEntry | not-accessible | current | Row definition for the dapiExpLineOdu4 table |
| 1.3.6.1.4.1.20044.76.9.25.1.1.1 | Columnpmo10010CfgLineDapiExpOduIndex | read-only | current | Index definition for the lineDapiExpOdu table |
| 1.3.6.1.4.1.20044.76.9.25.1.1.3 | Columnpmo10010CfgLineDapiExpSetupOduPortn | read-write | current | ODU4 Line Expected DAPI :This register defines the value of the expected Trace Identifier on the line input |
| 1.3.6.1.4.1.20044.76.9.26 | Nodepmo10010CfgDapiAccLineOdu4 | |||
| 1.3.6.1.4.1.20044.76.9.26.1 | Tablepmo10010CfgLineDapiAccOduTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.76.9.26.1.1 | Rowpmo10010CfgLineDapiAccOduEntry | not-accessible | current | Row definition for the dapiAccLineOdu4 table |
| 1.3.6.1.4.1.20044.76.9.26.1.1.1 | Columnpmo10010CfgLineDapiAccOduIndex | read-only | current | Index definition for the lineDapiAccOdu table |
| 1.3.6.1.4.1.20044.76.9.26.1.1.3 | Columnpmo10010CfgLineDapiAccSetupOduPortn | read-write | deprecated | ODU4 Line Accepted DAPI :This register defines the value of the accepted Trace Identifier on the line input |
| 1.3.6.1.4.1.20044.76.9.27 | Nodepmo10010CfgStartuptablefive | |||
| 1.3.6.1.4.1.20044.76.9.27.1 | Tablepmo10010CfgOtxtlhcapabilitiesTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.76.9.27.1.1 | Rowpmo10010CfgOtxtlhcapabilitiesEntry | not-accessible | current | Row definition for the startuptablefive table |
| 1.3.6.1.4.1.20044.76.9.27.1.1.1 | Columnpmo10010CfgOtxtlhcapabilitiesIndex | read-only | current | Index definition for the otxtlhcapabilities table |
| 1.3.6.1.4.1.20044.76.9.27.1.1.3 | Columnpmo10010CfgComponentTypePortn | read-only | current | Component parameters :This OID defines the component parameters |
| 1.3.6.1.4.1.20044.76.9.27.1.1.4 | Columnpmo10010CfgMiscellaneousPortn | read-only | current | Miscellaneous default settings :This OID defines the miscellaneous parameters |
| 1.3.6.1.4.1.20044.76.9.27.1.1.5 | Columnpmo10010CfgFirstChannelPortn | read-only | current | Number of the first channel of the component :This OID defines the first channel number of the PM |
| 1.3.6.1.4.1.20044.76.9.27.1.1.6 | Columnpmo10010CfgLastChannelPortn | read-only | current | Number of the last channel of the component :This OID defines the last channel number of the PM |
| 1.3.6.1.4.1.20044.76.9.27.1.1.7 | Columnpmo10010CfgGridPortn | read-only | current | Grid value of the component :This OID defines the grid of the PM |
| 1.3.6.1.4.1.20044.76.9.257 | Scalarpmo10010CfgWriteConfiguration | read-write | current | Write configuration to module:This OID writes the complete configuration to the module |
| 1.3.6.1.4.1.20044.76.10 | Nodepmo10010traps | |||
| 1.3.6.1.4.1.20044.76.10.2 | Scalarpmo10010trapPortNumber | read-only | current | Last port which generates a trap |
| 1.3.6.1.4.1.20044.76.10.3 | Scalarpmo10010trapLineNumber | read-only | current | Last Line which generates a trap |
| 1.3.6.1.4.1.20044.76.10.4 | Scalarpmo10010trapBoardNumber | read-only | current | Last module which generates a trap |
| 1.3.6.1.4.1.20044.76.10.30 | Notificationpmo10010LineTrapNotUrgentGoesOn | current | Not urgent Line default is activated | |
| 1.3.6.1.4.1.20044.76.10.31 | Notificationpmo10010LineTrapNotUrgentGoesOff | current | Not urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.76.10.32 | Notificationpmo10010LineTrapUrgentGoesOn | current | Urgent Line default is activated | |
| 1.3.6.1.4.1.20044.76.10.33 | Notificationpmo10010LineTrapUrgentGoesOff | current | Urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.76.10.34 | Notificationpmo10010LineTrapCritGoesOn | current | Critical Line default is activated | |
| 1.3.6.1.4.1.20044.76.10.35 | Notificationpmo10010LineTrapCritGoesOff | current | Critical Line default disappeared | |
| 1.3.6.1.4.1.20044.76.10.40 | Notificationpmo10010ClientTrapNotUrgentGoesOn | current | Not urgent client default is activated | |
| 1.3.6.1.4.1.20044.76.10.41 | Notificationpmo10010ClientTrapNotUrgentGoesOff | current | Not urgent client default disappeared | |
| 1.3.6.1.4.1.20044.76.10.42 | Notificationpmo10010ClientTrapUrgentGoesOn | current | Urgent client default is activated | |
| 1.3.6.1.4.1.20044.76.10.43 | Notificationpmo10010ClientTrapUrgentGoesOff | current | Urgent client default disappeared | |
| 1.3.6.1.4.1.20044.76.10.44 | Notificationpmo10010ClientTrapCritGoesOn | current | Critical client default is activated | |
| 1.3.6.1.4.1.20044.76.10.45 | Notificationpmo10010ClientTrapCritGoesOff | current | Critical client default disappeared | |
| 1.3.6.1.4.1.20044.76.10.50 | Notificationpmo10010PowerTrapUrgentGoesOn | current | Urgent power supply default is activated | |
| 1.3.6.1.4.1.20044.76.10.51 | Notificationpmo10010PowerTrapUrgentGoesOff | current | Urgent power supply default disappeared | |
| 1.3.6.1.4.1.20044.76.11 | Nodepmo10010Monitoring | |||
| 1.3.6.1.4.1.20044.76.11.1 | Nodepmo10010MonOther | |||
| 1.3.6.1.4.1.20044.76.11.1.3 | Nodepmo10010MonRmon | |||
| 1.3.6.1.4.1.20044.76.11.2 | Nodepmo10010MonClient | |||
| 1.3.6.1.4.1.20044.76.11.2.4 | Nodepmo10010MonClientRmonCounter | |||
| 1.3.6.1.4.1.20044.76.11.2.4.16 | Tablepmo10010MonupRmonBytesCounterClientInputTable | not-accessible | current | List of pmo10010MonupRmonBytesCounterClientInput Article |
| 1.3.6.1.4.1.20044.76.11.2.4.16.1 | Rowpmo10010MonupRmonBytesCounterClientInputEntry | not-accessible | current | Row definition for the pmo10010MonupRmonBytesCounterClientInput table |
| 1.3.6.1.4.1.20044.76.11.2.4.16.1.1 | Columnpmo10010MonupRmonBytesCounterClientInputIndex | read-only | current | Index definition for the pmo10010MonupRmonBytesCounterClientInput table |
| 1.3.6.1.4.1.20044.76.11.2.4.16.1.2 | Columnpmo10010MonupRmonBytesCounterClientInputValuePortn | read-only | current | Client Input Bytes :This counter is increased each time a data byte is received on the client port <Help> This counter gives the number of bytes received on th… |
| 1.3.6.1.4.1.20044.76.11.2.4.16.1.3 | Columnpmo10010MonupRmonBytesCounterClientInputErrorPortn | read-only | current | Bytes Counter Error :This OID when set indicates the Bytes counter value is invalid on client port |
| 1.3.6.1.4.1.20044.76.11.2.4.16.1.4 | Columnpmo10010MonupRmonBytesCounterClientInputOverloadPortn | read-only | current | Bytes Counter Overload :This OID when set indicates a Bytes counter overload on client port |
| 1.3.6.1.4.1.20044.76.11.2.4.32 | Tablepmo10010MonupRmonFcsErrorsCounterClientInputTable | not-accessible | current | List of pmo10010MonupRmonFcsErrorsCounterClientInput Article |
| 1.3.6.1.4.1.20044.76.11.2.4.32.1 | Rowpmo10010MonupRmonFcsErrorsCounterClientInputEntry | not-accessible | current | Row definition for the pmo10010MonupRmonFcsErrorsCounterClientInput table |
| 1.3.6.1.4.1.20044.76.11.2.4.32.1.1 | Columnpmo10010MonupRmonFcsErrorsCounterClientInputIndex | read-only | current | Index definition for the pmo10010MonupRmonFcsErrorsCounterClientInput table |
| 1.3.6.1.4.1.20044.76.11.2.4.32.1.2 | Columnpmo10010MonupRmonFcsErrorsCounterClientInputValuePortn | read-only | current | Client Input FCS Errors :This counter is increased each time a FCS error is detected on the client port <Help> This counter gives the number of FCS Errors rece… |
| 1.3.6.1.4.1.20044.76.11.2.4.32.1.3 | Columnpmo10010MonupRmonFcsErrorsCounterClientInputErrorPortn | read-only | current | FCS Errors Counter Error :This OID when set indicates the FCS Errors counter value is invalid on client port |
| 1.3.6.1.4.1.20044.76.11.2.4.32.1.4 | Columnpmo10010MonupRmonFcsErrorsCounterClientInputOverloadPortn | read-only | current | FCS Errors Counter Overload :This OID when set indicates a FCS Errors counter overload on client port |
| 1.3.6.1.4.1.20044.76.11.2.4.48 | Tablepmo10010MonupRmonPacketsCounterClientInputTable | not-accessible | current | List of pmo10010MonupRmonPacketsCounterClientInput Article |
| 1.3.6.1.4.1.20044.76.11.2.4.48.1 | Rowpmo10010MonupRmonPacketsCounterClientInputEntry | not-accessible | current | Row definition for the pmo10010MonupRmonPacketsCounterClientInput table |
| 1.3.6.1.4.1.20044.76.11.2.4.48.1.1 | Columnpmo10010MonupRmonPacketsCounterClientInputIndex | read-only | current | Index definition for the pmo10010MonupRmonPacketsCounterClientInput table |
| 1.3.6.1.4.1.20044.76.11.2.4.48.1.2 | Columnpmo10010MonupRmonPacketsCounterClientInputValuePortn | read-only | current | Client Input Packets :This counter is increased each time a packet is received on the client port <Help> This counter gives the number of packets received on t… |
| 1.3.6.1.4.1.20044.76.11.2.4.48.1.3 | Columnpmo10010MonupRmonPacketsCounterClientInputErrorPortn | read-only | current | Packets Counter Error :This OID when set indicates the Packets counter value is invalid on client port |
| 1.3.6.1.4.1.20044.76.11.2.4.48.1.4 | Columnpmo10010MonupRmonPacketsCounterClientInputOverloadPortn | read-only | current | Packets Counter Overload :This OID when set indicates a Packets counter overload on client port |
| 1.3.6.1.4.1.20044.76.11.2.4.64 | Tablepmo10010MonupRmonBroadcastCounterClientInputTable | not-accessible | current | List of pmo10010MonupRmonBroadcastCounterClientInput Article |
| 1.3.6.1.4.1.20044.76.11.2.4.64.1 | Rowpmo10010MonupRmonBroadcastCounterClientInputEntry | not-accessible | current | Row definition for the pmo10010MonupRmonBroadcastCounterClientInput table |
| 1.3.6.1.4.1.20044.76.11.2.4.64.1.1 | Columnpmo10010MonupRmonBroadcastCounterClientInputIndex | read-only | current | Index definition for the pmo10010MonupRmonBroadcastCounterClientInput table |
| 1.3.6.1.4.1.20044.76.11.2.4.64.1.2 | Columnpmo10010MonupRmonBroadcastCounterClientInputValuePortn | read-only | current | Client Input Broadcast Packets :This counter is increased each time a broadcast packet is received on the client port <Help> This counter gives the number of B… |
| 1.3.6.1.4.1.20044.76.11.2.4.64.1.3 | Columnpmo10010MonupRmonBroadcastCounterClientInputErrorPortn | read-only | current | Broadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.76.11.2.4.64.1.4 | Columnpmo10010MonupRmonBroadcastCounterClientInputOverloadPortn | read-only | current | Broadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port |
| 1.3.6.1.4.1.20044.76.11.2.4.80 | Tablepmo10010MonupRmonMulticastCounterClientInputTable | not-accessible | current | List of pmo10010MonupRmonMulticastCounterClientInput Article |
| 1.3.6.1.4.1.20044.76.11.2.4.80.1 | Rowpmo10010MonupRmonMulticastCounterClientInputEntry | not-accessible | current | Row definition for the pmo10010MonupRmonMulticastCounterClientInput table |
| 1.3.6.1.4.1.20044.76.11.2.4.80.1.1 | Columnpmo10010MonupRmonMulticastCounterClientInputIndex | read-only | current | Index definition for the pmo10010MonupRmonMulticastCounterClientInput table |
| 1.3.6.1.4.1.20044.76.11.2.4.80.1.2 | Columnpmo10010MonupRmonMulticastCounterClientInputValuePortn | read-only | current | Client Input Multicast Packets :This counter is increased each time a Multicast packet is received on the client port <Help> This counter gives the number of M… |
| 1.3.6.1.4.1.20044.76.11.2.4.80.1.3 | Columnpmo10010MonupRmonMulticastCounterClientInputErrorPortn | read-only | current | Multicast Counter Error :This OID when set indicates the Multicast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.76.11.2.4.80.1.4 | Columnpmo10010MonupRmonMulticastCounterClientInputOverloadPortn | read-only | current | Multicast Counter Overload :This OID when set indicates a Multicast counter overload on client port |
| 1.3.6.1.4.1.20044.76.11.2.4.96 | Tablepmo10010MonupRmonPauseFrameCounterClientInputTable | not-accessible | current | List of pmo10010MonupRmonPauseFrameCounterClientInput Article |
| 1.3.6.1.4.1.20044.76.11.2.4.96.1 | Rowpmo10010MonupRmonPauseFrameCounterClientInputEntry | not-accessible | current | Row definition for the pmo10010MonupRmonPauseFrameCounterClientInput table |
| 1.3.6.1.4.1.20044.76.11.2.4.96.1.1 | Columnpmo10010MonupRmonPauseFrameCounterClientInputIndex | read-only | current | Index definition for the pmo10010MonupRmonPauseFrameCounterClientInput table |
| 1.3.6.1.4.1.20044.76.11.2.4.96.1.2 | Columnpmo10010MonupRmonPauseFrameCounterClientInputValuePortn | read-only | current | Client Input Pause Frames :This counter is increased each time a Pause frame is received on the client port <Help> This counter gives the number of Pause frame… |
| 1.3.6.1.4.1.20044.76.11.2.4.96.1.3 | Columnpmo10010MonupRmonPauseFrameCounterClientInputErrorPortn | read-only | current | Pause Counter Error :This OID when set indicates the Pause counter value is invalid on client port |
| 1.3.6.1.4.1.20044.76.11.2.4.96.1.4 | Columnpmo10010MonupRmonPauseFrameCounterClientInputOverloadPortn | read-only | current | Pause Counter Overload :This OID when set indicates a Pause counter overload on client port |
| 1.3.6.1.4.1.20044.76.11.2.4.160 | Tablepmo10010MonupRmonUnicastCounterClientInputTable | not-accessible | current | List of pmo10010MonupRmonUnicastCounterClientInput Article |
| 1.3.6.1.4.1.20044.76.11.2.4.160.1 | Rowpmo10010MonupRmonUnicastCounterClientInputEntry | not-accessible | current | Row definition for the pmo10010MonupRmonUnicastCounterClientInput table |
| 1.3.6.1.4.1.20044.76.11.2.4.160.1.1 | Columnpmo10010MonupRmonUnicastCounterClientInputIndex | read-only | current | Index definition for the pmo10010MonupRmonUnicastCounterClientInput table |
| 1.3.6.1.4.1.20044.76.11.2.4.160.1.2 | Columnpmo10010MonupRmonUnicastCounterClientInputValuePortn | read-only | current | Client Input Unicast Packets :This counter is increased each time a Unicast packet is received on the client port <Help> This counter gives the number of Unica… |
| 1.3.6.1.4.1.20044.76.11.2.4.160.1.3 | Columnpmo10010MonupRmonUnicastCounterClientInputErrorPortn | read-only | current | Unicast Counter Error :This OID when set indicates the Unicast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.76.11.2.4.160.1.4 | Columnpmo10010MonupRmonUnicastCounterClientInputOverloadPortn | read-only | current | Unicast Counter Overload :This OID when set indicates a Unicast counter overload on client port |
| 1.3.6.1.4.1.20044.76.11.2.4.176 | Tablepmo10010MonupRmonNonunicastCounterClientInputTable | not-accessible | current | List of pmo10010MonupRmonNonunicastCounterClientInput Article |
| 1.3.6.1.4.1.20044.76.11.2.4.176.1 | Rowpmo10010MonupRmonNonunicastCounterClientInputEntry | not-accessible | current | Row definition for the pmo10010MonupRmonNonunicastCounterClientInput table |
| 1.3.6.1.4.1.20044.76.11.2.4.176.1.1 | Columnpmo10010MonupRmonNonunicastCounterClientInputIndex | read-only | current | Index definition for the pmo10010MonupRmonNonunicastCounterClientInput table |
| 1.3.6.1.4.1.20044.76.11.2.4.176.1.2 | Columnpmo10010MonupRmonNonunicastCounterClientInputValuePortn | read-only | current | Client Input Non Unicast Packets :This counter is increased each time a Non-Unicast packet is received on the client port <Help> This counter gives the number … |
| 1.3.6.1.4.1.20044.76.11.2.4.176.1.3 | Columnpmo10010MonupRmonNonunicastCounterClientInputErrorPortn | read-only | current | Non Unicast Counter Error :This OID when set indicates the Non-Unicast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.76.11.2.4.176.1.4 | Columnpmo10010MonupRmonNonunicastCounterClientInputOverloadPortn | read-only | current | Non Unicast Counter Overload :This OID when set indicates a Non-Unicast counter overload on client port |
| 1.3.6.1.4.1.20044.76.11.2.4.208 | Tablepmo10010MondownRmonBytesCounterClientOutputTable | not-accessible | current | List of pmo10010MondownRmonBytesCounterClientOutput Article |
| 1.3.6.1.4.1.20044.76.11.2.4.208.1 | Rowpmo10010MondownRmonBytesCounterClientOutputEntry | not-accessible | current | Row definition for the pmo10010MondownRmonBytesCounterClientOutput table |
| 1.3.6.1.4.1.20044.76.11.2.4.208.1.1 | Columnpmo10010MondownRmonBytesCounterClientOutputIndex | read-only | current | Index definition for the pmo10010MondownRmonBytesCounterClientOutput table |
| 1.3.6.1.4.1.20044.76.11.2.4.208.1.2 | Columnpmo10010MondownRmonBytesCounterClientOutputValuePortn | read-only | current | Client Output Bytes :This counter is increased each time a data byte is transmitted on the client port <Help> This counter gives the number of bytes transmitte… |
| 1.3.6.1.4.1.20044.76.11.2.4.208.1.3 | Columnpmo10010MondownRmonBytesCounterClientOutputErrorPortn | read-only | current | Bytes Counter Error :This OID when set indicates the Bytes counter value is invalid on client port |
| 1.3.6.1.4.1.20044.76.11.2.4.208.1.4 | Columnpmo10010MondownRmonBytesCounterClientOutputOverloadPortn | read-only | current | Bytes Counter Overload :This OID when set indicates a Bytes counter overload on client port |
| 1.3.6.1.4.1.20044.76.11.2.4.224 | Tablepmo10010MondownRmonFcsErrorsCounterClientOutputTable | not-accessible | current | List of pmo10010MondownRmonFcsErrorsCounterClientOutput Article |
| 1.3.6.1.4.1.20044.76.11.2.4.224.1 | Rowpmo10010MondownRmonFcsErrorsCounterClientOutputEntry | not-accessible | current | Row definition for the pmo10010MondownRmonFcsErrorsCounterClientOutput table |
| 1.3.6.1.4.1.20044.76.11.2.4.224.1.1 | Columnpmo10010MondownRmonFcsErrorsCounterClientOutputIndex | read-only | current | Index definition for the pmo10010MondownRmonFcsErrorsCounterClientOutput table |
| 1.3.6.1.4.1.20044.76.11.2.4.224.1.2 | Columnpmo10010MondownRmonFcsErrorsCounterClientOutputValuePortn | read-only | current | Client Output FCS Errors :This counter is increased each time a FCS error is detected on the transmit client port <Help> This counter gives the number of FCS E… |
| 1.3.6.1.4.1.20044.76.11.2.4.224.1.3 | Columnpmo10010MondownRmonFcsErrorsCounterClientOutputErrorPortn | read-only | current | FCS Errors Counter Error :This OID when set indicates the FCS Errors counter value is invalid on client port |
| 1.3.6.1.4.1.20044.76.11.2.4.224.1.4 | Columnpmo10010MondownRmonFcsErrorsCounterClientOutputOverloadPortn | read-only | current | FCS Errors Counter Overload :This OID when set indicates a FCS Errors counter overload on client port |
| 1.3.6.1.4.1.20044.76.11.2.4.240 | Tablepmo10010MondownRmonPacketsCounterClientOutputTable | not-accessible | current | List of pmo10010MondownRmonPacketsCounterClientOutput Article |
| 1.3.6.1.4.1.20044.76.11.2.4.240.1 | Rowpmo10010MondownRmonPacketsCounterClientOutputEntry | not-accessible | current | Row definition for the pmo10010MondownRmonPacketsCounterClientOutput table |
| 1.3.6.1.4.1.20044.76.11.2.4.240.1.1 | Columnpmo10010MondownRmonPacketsCounterClientOutputIndex | read-only | current | Index definition for the pmo10010MondownRmonPacketsCounterClientOutput table |
| 1.3.6.1.4.1.20044.76.11.2.4.240.1.2 | Columnpmo10010MondownRmonPacketsCounterClientOutputValuePortn | read-only | current | Client Output Packets :This counter is increased each time a packet is transmitted on the client port <Help> This counter gives the number of packets transmitt… |
| 1.3.6.1.4.1.20044.76.11.2.4.240.1.3 | Columnpmo10010MondownRmonPacketsCounterClientOutputErrorPortn | read-only | current | Packets Counter Error :This OID when set indicates the Packets counter value is invalid on client port |
| 1.3.6.1.4.1.20044.76.11.2.4.240.1.4 | Columnpmo10010MondownRmonPacketsCounterClientOutputOverloadPortn | read-only | current | Packets Counter Overload :This OID when set indicates a Packets counter overload on client port |
| 1.3.6.1.4.1.20044.76.11.2.4.256 | Tablepmo10010MondownRmonBroadcastCounterClientOutputTable | not-accessible | current | List of pmo10010MondownRmonBroadcastCounterClientOutput Article |
| 1.3.6.1.4.1.20044.76.11.2.4.256.1 | Rowpmo10010MondownRmonBroadcastCounterClientOutputEntry | not-accessible | current | Row definition for the pmo10010MondownRmonBroadcastCounterClientOutput table |
| 1.3.6.1.4.1.20044.76.11.2.4.256.1.1 | Columnpmo10010MondownRmonBroadcastCounterClientOutputIndex | read-only | current | Index definition for the pmo10010MondownRmonBroadcastCounterClientOutput table |
| 1.3.6.1.4.1.20044.76.11.2.4.256.1.2 | Columnpmo10010MondownRmonBroadcastCounterClientOutputValuePortn | read-only | current | Client Output Broadcast Packets :This counter is increased each time a broadcast packet is transmitted on the client port <Help> This counter gives the number … |
| 1.3.6.1.4.1.20044.76.11.2.4.256.1.3 | Columnpmo10010MondownRmonBroadcastCounterClientOutputErrorPortn | read-only | current | Broadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.76.11.2.4.256.1.4 | Columnpmo10010MondownRmonBroadcastCounterClientOutputOverloadPortn | read-only | current | Broadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port |
| 1.3.6.1.4.1.20044.76.11.2.4.272 | Tablepmo10010MondownRmonMulticastCounterClientOutputTable | not-accessible | current | List of pmo10010MondownRmonMulticastCounterClientOutput Article |
| 1.3.6.1.4.1.20044.76.11.2.4.272.1 | Rowpmo10010MondownRmonMulticastCounterClientOutputEntry | not-accessible | current | Row definition for the pmo10010MondownRmonMulticastCounterClientOutput table |
| 1.3.6.1.4.1.20044.76.11.2.4.272.1.1 | Columnpmo10010MondownRmonMulticastCounterClientOutputIndex | read-only | current | Index definition for the pmo10010MondownRmonMulticastCounterClientOutput table |
| 1.3.6.1.4.1.20044.76.11.2.4.272.1.2 | Columnpmo10010MondownRmonMulticastCounterClientOutputValuePortn | read-only | current | Client Output Multicast Packets :This counter is increased each time a Multicast packet is transmitted on the client port <Help> This counter gives the number … |
| 1.3.6.1.4.1.20044.76.11.2.4.272.1.3 | Columnpmo10010MondownRmonMulticastCounterClientOutputErrorPortn | read-only | current | Multicast Counter Error :This OID when set indicates the Multicast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.76.11.2.4.272.1.4 | Columnpmo10010MondownRmonMulticastCounterClientOutputOverloadPortn | read-only | current | Multicast Counter Overload :This OID when set indicates a Multicast counter overload on client port |
| 1.3.6.1.4.1.20044.76.11.2.4.288 | Tablepmo10010MondownRmonPauseFrameCounterClientOutputTable | not-accessible | current | List of pmo10010MondownRmonPauseFrameCounterClientOutput Article |
| 1.3.6.1.4.1.20044.76.11.2.4.288.1 | Rowpmo10010MondownRmonPauseFrameCounterClientOutputEntry | not-accessible | current | Row definition for the pmo10010MondownRmonPauseFrameCounterClientOutput table |
| 1.3.6.1.4.1.20044.76.11.2.4.288.1.1 | Columnpmo10010MondownRmonPauseFrameCounterClientOutputIndex | read-only | current | Index definition for the pmo10010MondownRmonPauseFrameCounterClientOutput table |
| 1.3.6.1.4.1.20044.76.11.2.4.288.1.2 | Columnpmo10010MondownRmonPauseFrameCounterClientOutputValuePortn | read-only | current | Client Output Pause Frames :This counter is increased each time a Pause frame is transmitted on the client port <Help> This counter gives the number of Pause f… |
| 1.3.6.1.4.1.20044.76.11.2.4.288.1.3 | Columnpmo10010MondownRmonPauseFrameCounterClientOutputErrorPortn | read-only | current | Pause Counter Error :This OID when set indicates the Pause counter value is invalid on client port |
| 1.3.6.1.4.1.20044.76.11.2.4.288.1.4 | Columnpmo10010MondownRmonPauseFrameCounterClientOutputOverloadPortn | read-only | current | Pause Counter Overload :This OID when set indicates a Pause counter overload on client port |
| 1.3.6.1.4.1.20044.76.11.2.4.352 | Tablepmo10010MondownRmonUnicastCounterClientOutputTable | not-accessible | current | List of pmo10010MondownRmonUnicastCounterClientOutput Article |
| 1.3.6.1.4.1.20044.76.11.2.4.352.1 | Rowpmo10010MondownRmonUnicastCounterClientOutputEntry | not-accessible | current | Row definition for the pmo10010MondownRmonUnicastCounterClientOutput table |
| 1.3.6.1.4.1.20044.76.11.2.4.352.1.1 | Columnpmo10010MondownRmonUnicastCounterClientOutputIndex | read-only | current | Index definition for the pmo10010MondownRmonUnicastCounterClientOutput table |
| 1.3.6.1.4.1.20044.76.11.2.4.352.1.2 | Columnpmo10010MondownRmonUnicastCounterClientOutputValuePortn | read-only | current | Client Output Unicast Packets :This counter is increased each time a Unicast packet is transmitted on the client port <Help> This counter gives the number of U… |
| 1.3.6.1.4.1.20044.76.11.2.4.352.1.3 | Columnpmo10010MondownRmonUnicastCounterClientOutputErrorPortn | read-only | current | Unicast Counter Error :This OID when set indicates the Unicast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.76.11.2.4.352.1.4 | Columnpmo10010MondownRmonUnicastCounterClientOutputOverloadPortn | read-only | current | Unicast Counter Overload :This OID when set indicates a Unicast counter overload on client port |
| 1.3.6.1.4.1.20044.76.11.2.4.368 | Tablepmo10010MondownRmonNonunicastCounterClientOutputTable | not-accessible | current | List of pmo10010MondownRmonNonunicastCounterClientOutput Article |
| 1.3.6.1.4.1.20044.76.11.2.4.368.1 | Rowpmo10010MondownRmonNonunicastCounterClientOutputEntry | not-accessible | current | Row definition for the pmo10010MondownRmonNonunicastCounterClientOutput table |
| 1.3.6.1.4.1.20044.76.11.2.4.368.1.1 | Columnpmo10010MondownRmonNonunicastCounterClientOutputIndex | read-only | current | Index definition for the pmo10010MondownRmonNonunicastCounterClientOutput table |
| 1.3.6.1.4.1.20044.76.11.2.4.368.1.2 | Columnpmo10010MondownRmonNonunicastCounterClientOutputValuePortn | read-only | current | Client Output Non Unicast Packets :This counter is increased each time a Non-Unicast packet is transmitted on the client port <Help> This counter gives the num… |
| 1.3.6.1.4.1.20044.76.11.2.4.368.1.3 | Columnpmo10010MondownRmonNonunicastCounterClientOutputErrorPortn | read-only | current | Non Unicast Counter Error :This OID when set indicates the Non-Unicast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.76.11.2.4.368.1.4 | Columnpmo10010MondownRmonNonunicastCounterClientOutputOverloadPortn | read-only | current | Non Unicast Counter Overload :This OID when set indicates a Non-Unicast counter overload on client port |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| Pmo10010AdjustValue | INTEGER { otxadjustvalue0(0), otxadjustvalue1(1), otxadjustvalue2(2), otxadjustvalue3(3), otxadjustvalue4(4), otxadjustvalue5(5), otxadjustvalue6(6), otxadjustvalue7(7), otxadjustvalue8(8), otxadjustvalue9(9), otxadjustvalue10(10) } | current | Different values in Adjust mode on OTX-TLH on client and line ports |
| Pmo10010ClientProtocol | INTEGER { protocolclientvalue0(0), protocolclientvalue1(1), protocolclientvalue2(2), protocolclientvalue3(3), protocolclientvalue4(4), protocolclientvalue5(5), protocolclientvalue6(6), protocolclientvalue7(7), protocolclientvalue8(8) } | current | Different values on the protocol on the client ports |
| Pmo10010MultiRate | INTEGER { rate100Mhz(0), rate250Mhz(1), rate500Mhz(2), rate1Ghz(3) } | current | different rate for a client port |
| Pmo10010Odu2SapiMode | INTEGER { off(0), sapi(1) dapi(2) sapidapi(3), } | current | Mode for SAPI-DAPI |
| Pmo10010OrxChannel | INTEGER | current | Channel selection on transceiver Rx line ports |
| Pmo10010Otu4SapiMode | INTEGER { off(0), sapi(1) dapi(2) sapidapi(3), } | current | Mode for SAPI-DAPI |
| Pmo10010OtxChannel | INTEGER | current | Channel selection on transceiver Tx line ports |
| Pmo10010OtxGrid | INTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50) } | current | Different grids on OTX-TLH on client and line ports |
| Pmo10010OtxMode | INTEGER { otx80mode(1), otx60mode(2), otxadjustmode(4) } | current | Different modes on OTX-TLH on client and line ports |
| Pmo10010ProtocolMode | INTEGER { protocolmodevalue0(0), protocolmodevalue1(1), protocolmodevalue2(2), protocolmodevalue3(3) } | current | Different values on the protocol mode |