MIB Viewer

EKINOPS-Pmo6006-MIB

517 objects
Creation.
OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.70IdentitymodulePmo6006Creation.
1.3.6.1.4.1.20044.70.2Nodepmo6006alarms
1.3.6.1.4.1.20044.70.2.1Nodepmo6006AlmOther
1.3.6.1.4.1.20044.70.2.1.1Nodepmo6006AlmOtherNurg
1.3.6.1.4.1.20044.70.2.1.1.2Nodepmo6006AlmsynthAlm2
1.3.6.1.4.1.20044.70.2.1.1.2.1Scalarpmo6006AlmConfTableSaveread-onlycurrentPM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> infor…
1.3.6.1.4.1.20044.70.2.1.1.2.2Scalarpmo6006AlmInvUploadread-onlycurrentInventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> informationalStatus(1000) <Alarmtype> ot…
1.3.6.1.4.1.20044.70.2.1.1.2.3Scalarpmo6006AlmConfTableLoadread-onlycurrentPM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> informationalStat…
1.3.6.1.4.1.20044.70.2.1.1.2.4Scalarpmo6006AlmCorrelatOffread-onlycurrentNot Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> informationalStatus(1000) <Alarmtype…
1.3.6.1.4.1.20044.70.2.1.2Nodepmo6006AlmOtherUrg
1.3.6.1.4.1.20044.70.2.1.3Nodepmo6006AlmOtherCrit
1.3.6.1.4.1.20044.70.2.1.3.0Nodepmo6006AlmsynthAlm0
1.3.6.1.4.1.20044.70.2.1.3.0.9Scalarpmo6006AlmModGlobFailread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the RM <Help> This alarm is set on detection of a failure originating from the equip…
1.3.6.1.4.1.20044.70.2.1.3.0.15Scalarpmo6006AlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.70.2.1.3.0.16Scalarpmo6006AlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.70.2.2Nodepmo6006AlmClient
1.3.6.1.4.1.20044.70.2.2.1Nodepmo6006AlmClientNurg
1.3.6.1.4.1.20044.70.2.2.1.232Tablepmo6006AlmclientSfpWarnDdmTablenot-accessiblecurrentList of pmo6006AlmclientSfpWarnDdm Article
1.3.6.1.4.1.20044.70.2.2.1.232.1Rowpmo6006AlmclientSfpWarnDdmEntrynot-accessiblecurrentRow definition for the pmo6006AlmclientSfpWarnDdm table
1.3.6.1.4.1.20044.70.2.2.1.232.1.1Columnpmo6006AlmclientSfpWarnDdmIndexread-onlycurrentIndex definition for the pmo6006AlmclientSfpWarnDdm table
1.3.6.1.4.1.20044.70.2.2.1.232.1.2Columnpmo6006AlmClientTxPwLowWngPortnread-onlycurrentClient Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.70.2.2.1.232.1.3Columnpmo6006AlmClientTxPwrHighWngPortnread-onlycurrentClient Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.70.2.2.1.232.1.4Columnpmo6006AlmClientTxBiasLowWngPortnread-onlycurrentClient Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.70.2.2.1.232.1.5Columnpmo6006AlmClientTxBiasHighWngPortnread-onlycurrentClient Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warn…
1.3.6.1.4.1.20044.70.2.2.1.232.1.6Columnpmo6006AlmClientVccLowWngPortnread-onlycurrentClient Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Warn…
1.3.6.1.4.1.20044.70.2.2.1.232.1.7Columnpmo6006AlmClientVccHighWngPortnread-onlycurrentClient Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Wa…
1.3.6.1.4.1.20044.70.2.2.1.232.1.8Columnpmo6006AlmClientTempLowWngPortnread-onlycurrentClient Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indic…
1.3.6.1.4.1.20044.70.2.2.1.232.1.9Columnpmo6006AlmClientTempHighWngPortnread-onlycurrentClient Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning ind…
1.3.6.1.4.1.20044.70.2.2.1.232.1.16Columnpmo6006AlmClientRxPwrLowWngPortnread-onlycurrentClient Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning i…
1.3.6.1.4.1.20044.70.2.2.1.232.1.17Columnpmo6006AlmClientRxPwrHighWngPortnread-onlycurrentClient Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning…
1.3.6.1.4.1.20044.70.2.2.2Nodepmo6006AlmClientUrg
1.3.6.1.4.1.20044.70.2.2.2.88Tablepmo6006AlmclientHostLaneFaultTablenot-accessiblecurrentList of pmo6006AlmclientHostLaneFault Article
1.3.6.1.4.1.20044.70.2.2.2.88.1Rowpmo6006AlmclientHostLaneFaultEntrynot-accessiblecurrentRow definition for the pmo6006AlmclientHostLaneFault table
1.3.6.1.4.1.20044.70.2.2.2.88.1.1Columnpmo6006AlmclientHostLaneFaultIndexread-onlycurrentIndex definition for the pmo6006AlmclientHostLaneFault table
1.3.6.1.4.1.20044.70.2.2.2.88.1.2Columnpmo6006AlmClientLossOfSyncPortnread-onlycurrentClient Frame Alignment Loss :This OID indicates the module is not aligned with the incoming Client signal <Help> Alarm indicating the module is not aligned wit…
1.3.6.1.4.1.20044.70.2.2.2.88.1.3Columnpmo6006AlmClientInputLossOfSigPortnread-onlycurrentClient Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Client Trscv <Help> Alarm indicating a Loss of Signal is detected on the Cl…
1.3.6.1.4.1.20044.70.2.2.2.88.1.4Columnpmo6006AlmClientOdu2eDplmPortnread-onlycurrentODU2e DPLM :This OID indicates a Payload Mismatch is detected on the Client port<Help> Alarm indicating a Payload Mismatch <Condtype> CLIENT_ODU2E_DPLM <Probca…
1.3.6.1.4.1.20044.70.2.2.2.88.1.6Columnpmo6006AlmClientOdu2eDdegPortnread-onlycurrentODU2e DDEG :This OID indicates that a Signal Degrade has been detected on client port<Help> Alarm indicating a Signal Degrade upon threshold and confirmation p…
1.3.6.1.4.1.20044.70.2.2.2.88.1.7Columnpmo6006AlmClientCsfDetectedPortnread-onlycurrentETH DCSF :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client Signal Fail has be…
1.3.6.1.4.1.20044.70.2.2.2.88.1.8Columnpmo6006AlmClientOdu2eIaisPortnread-onlycurrentODU2e IAIS :This OID indicates that an Alarm Indication Signal has been inserted on client port <Help> This alarm indicates if an Alarm Indication Signal has b…
1.3.6.1.4.1.20044.70.2.2.2.88.1.9Columnpmo6006AlmClientOdu2eDtimPortnread-onlycurrentODU2e DTIM :This OID indicates that a Trace Identifier Mismatch has been detected on client port<Help> This alarm indicates if an Trace Identifier Mismatch has…
1.3.6.1.4.1.20044.70.2.2.2.88.1.10Columnpmo6006AlmClientOdu2eDaisPortnread-onlycurrentODU2e DAIS :This OID indicates that a Alarm Indication SIgnal has been detected on client port<Help> This alarm indicates if an Alarm Indication Signal has bee…
1.3.6.1.4.1.20044.70.2.2.2.88.1.11Columnpmo6006AlmClientLaneTxFifoErrorPortnread-onlycurrentClient Tx FIFO Error :This OID indicates a Tx FIFO Error on the Client Trscv <Help> Alarm indicating a Tx FIFO Error on the Client Trscv <Condtype> CLIENT_LANE…
1.3.6.1.4.1.20044.70.2.2.2.88.1.12Columnpmo6006AlmClientOdu2eIociPortnread-onlycurrentODU2e IOCI :This OID indicates that an Open Connection has been inserted on client port <Help> This alarm indicates if an Open Connection Indication has been i…
1.3.6.1.4.1.20044.70.2.2.2.88.1.13Columnpmo6006AlmClientOdu2eDociPortnread-onlycurrentODU2e DOCI :This OID indicates that a Open Connection has been detected on client port <Help> This alarm indicates if an Open Connection Indication has been de…
1.3.6.1.4.1.20044.70.2.2.2.88.1.14Columnpmo6006AlmClientOdu2eIbdiPortnread-onlycurrentODU2e IBDI :This OID indicates that a Backward Defect Indication has been inserted on client port <Help> This alarm indicates if a Backward Defect Indication h…
1.3.6.1.4.1.20044.70.2.2.2.88.1.15Columnpmo6006AlmClientOdu2eDbdiPortnread-onlycurrentODU2e DBDI :This OID indicates that a Backward Defect Indication has been detected on client port<Help> This alarm indicates if a Backward Defect Indication ha…
1.3.6.1.4.1.20044.70.2.2.2.88.1.16Columnpmo6006AlmClientOdu2eIlckPortnread-onlycurrentODU2e ILCK :This OID indicates that a Locked Indication has been inserted on client port <Help> This alarm indicates if a Locked Indication has been inserted o…
1.3.6.1.4.1.20044.70.2.2.2.88.1.17Columnpmo6006AlmClientOdu2eDlckPortnread-onlycurrentODU2e DLCK :This OID indicates that a Locked Indication has been detected on client port <Help> This alarm indicates if a Locked Indication has been detected o…
1.3.6.1.4.1.20044.70.2.2.2.216Tablepmo6006AlmclientSfpAlmDdmTablenot-accessiblecurrentList of pmo6006AlmclientSfpAlmDdm Article
1.3.6.1.4.1.20044.70.2.2.2.216.1Rowpmo6006AlmclientSfpAlmDdmEntrynot-accessiblecurrentRow definition for the pmo6006AlmclientSfpAlmDdm table
1.3.6.1.4.1.20044.70.2.2.2.216.1.1Columnpmo6006AlmclientSfpAlmDdmIndexread-onlycurrentIndex definition for the pmo6006AlmclientSfpAlmDdm table
1.3.6.1.4.1.20044.70.2.2.2.216.1.2Columnpmo6006AlmClientTxPwrLowAlaPortnread-onlycurrentClient Trscv Tx Power Low :This OID indicates that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in…
1.3.6.1.4.1.20044.70.2.2.2.216.1.3Columnpmo6006AlmClientTxPwrHighAlaPortnread-onlycurrentClient Trscv Tx Power High :This OID indicates that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.70.2.2.2.216.1.4Columnpmo6006AlmClientTxBiasLowAlaPortnread-onlycurrentClient Trscv Bias Low :This OID indicates that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.70.2.2.2.216.1.5Columnpmo6006AlmClientTxBiasHighAlaPortnread-onlycurrentClient Trscv Bias High :This OID indicates that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM <Help> Alar…
1.3.6.1.4.1.20044.70.2.2.2.216.1.6Columnpmo6006AlmClientVccLowAlaPortnread-onlycurrentClient Trscv Power Supply Low :This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM <Help> Alar…
1.3.6.1.4.1.20044.70.2.2.2.216.1.7Columnpmo6006AlmClientVccHighAlaPortnread-onlycurrentClient Trscv Power Supply High :This OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM <Help> Al…
1.3.6.1.4.1.20044.70.2.2.2.216.1.8Columnpmo6006AlmClientTempLowAlaPortnread-onlycurrentClient Trscv Temp Low :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicat…
1.3.6.1.4.1.20044.70.2.2.2.216.1.9Columnpmo6006AlmClientTempHighAlaPortnread-onlycurrentClient Trscv Temp High :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indic…
1.3.6.1.4.1.20044.70.2.2.2.216.1.16Columnpmo6006AlmClientRxPwrLowAlaPortnread-onlycurrentClient Trscv Rx Power Low :This OID indicates that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm ind…
1.3.6.1.4.1.20044.70.2.2.2.216.1.17Columnpmo6006AlmClientRxPwrHighAlaPortnread-onlycurrentClient Trscv Rx Power High :This OID indicates that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm i…
1.3.6.1.4.1.20044.70.2.2.3Nodepmo6006AlmClientCrit
1.3.6.1.4.1.20044.70.2.2.3.8Tablepmo6006AlmsynthAlmPortTablenot-accessiblecurrentList of pmo6006AlmsynthAlmPort Article
1.3.6.1.4.1.20044.70.2.2.3.8.1Rowpmo6006AlmsynthAlmPortEntrynot-accessiblecurrentRow definition for the pmo6006AlmsynthAlmPort table
1.3.6.1.4.1.20044.70.2.2.3.8.1.1Columnpmo6006AlmsynthAlmPortIndexread-onlycurrentIndex definition for the pmo6006AlmsynthAlmPort table
1.3.6.1.4.1.20044.70.2.2.3.8.1.2Columnpmo6006AlmSfpAbsentPortnread-onlycurrentClient SFP Absent :This OID indicates that the Transceiver is not present in the client port. <Help> This alarm indicates if the client transceiver is not plug…
1.3.6.1.4.1.20044.70.2.2.3.8.1.3Columnpmo6006AlmDdmAbsentPortnread-onlycurrentDDM Supported On Client Trscv :This OID indicates that the Client transceiver supports the Digital Diagnostic Monitoring function <Help> This status indicates …
1.3.6.1.4.1.20044.70.2.2.3.8.1.5Columnpmo6006AlmHwFailAccPortnread-onlycurrentClient HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Help> This alarm indicates a failure on client port, most pro…
1.3.6.1.4.1.20044.70.2.2.3.8.1.6Columnpmo6006AlmDwLsdPortnread-onlycurrentClient SFP Laser Shutdown :This OID indicates the Client transceiver laser is shutdown <Help> This status indicates if the client transceiver laser is shutdown…
1.3.6.1.4.1.20044.70.2.2.3.8.1.7Columnpmo6006AlmClientLocalOosPortnread-onlycurrentLocal Client Port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local c…
1.3.6.1.4.1.20044.70.2.2.3.8.1.8Columnpmo6006AlmClientRemoteOosPortnread-onlycurrentRemote Client Port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the remot…
1.3.6.1.4.1.20044.70.2.2.3.8.1.9Columnpmo6006AlmDwCaisPortnread-onlycurrentClient AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indicates if a Client Alarm Indication Signal is…
1.3.6.1.4.1.20044.70.2.2.3.8.1.10Columnpmo6006AlmSfpDdmWarningPortnread-onlycurrentWarning On Client Trscv DDM :This OID indicates a warning is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Warning has be…
1.3.6.1.4.1.20044.70.2.2.3.8.1.11Columnpmo6006AlmSfpDdmAlmPortnread-onlycurrentAlarm On Client Trscv DDM :This OID indicates an alarm is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Alarm has been de…
1.3.6.1.4.1.20044.70.2.2.3.8.1.13Columnpmo6006AlmFailAccPortnread-onlycurrentClient Access Fail :This OID indicates a failure on the Client port <Help> This alarm indicates a failure on the Client port <Condtype> FAIL_ACC_1 <Probcause> …
1.3.6.1.4.1.20044.70.2.2.3.8.1.17Columnpmo6006AlmUpCsfPortnread-onlycurrentClient Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu…
1.3.6.1.4.1.20044.70.2.3Nodepmo6006AlmLine
1.3.6.1.4.1.20044.70.2.3.1Nodepmo6006AlmLineNurg
1.3.6.1.4.1.20044.70.2.3.2Nodepmo6006AlmLineUrg
1.3.6.1.4.1.20044.70.2.3.2.104Tablepmo6006AlmlineNetworkLaneAlarmWarning1Tablenot-accessiblecurrentList of pmo6006AlmlineNetworkLaneAlarmWarning1 Article
1.3.6.1.4.1.20044.70.2.3.2.104.1Rowpmo6006AlmlineNetworkLaneAlarmWarning1Entrynot-accessiblecurrentRow definition for the pmo6006AlmlineNetworkLaneAlarmWarning1 table
1.3.6.1.4.1.20044.70.2.3.2.104.1.1Columnpmo6006AlmlineNetworkLaneAlarmWarning1Indexread-onlycurrentIndex definition for the pmo6006AlmlineNetworkLaneAlarmWarning1 table
1.3.6.1.4.1.20044.70.2.3.2.104.1.2Columnpmo6006AlmLineTxPwrLowAlaPortnread-onlycurrentLine Trscv Tx Power Low :This OID indicates that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indi…
1.3.6.1.4.1.20044.70.2.3.2.104.1.3Columnpmo6006AlmLineTxPwrHighAlaPortnread-onlycurrentLine Trscv Tx Power High :This OID indicates that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm in…
1.3.6.1.4.1.20044.70.2.3.2.104.1.4Columnpmo6006AlmLineTxBiasLowAlaPortnread-onlycurrentLine Trscv Bias Low :This OID indicates that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in…
1.3.6.1.4.1.20044.70.2.3.2.104.1.5Columnpmo6006AlmLineTxBiasHighAlaPortnread-onlycurrentLine Trscv Bias High :This OID indicates that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.70.2.3.2.104.1.6Columnpmo6006AlmLineVccLowAlaPortnread-onlycurrentLine Trscv Power Supply Low :This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.70.2.3.2.104.1.7Columnpmo6006AlmLineVccHighAlaPortnread-onlycurrentLine Trscv Power Supply High :This OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM <Help> Alar…
1.3.6.1.4.1.20044.70.2.3.2.104.1.8Columnpmo6006AlmLineTempLowAlaPortnread-onlycurrentLine Trscv Temp Low :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicatin…
1.3.6.1.4.1.20044.70.2.3.2.104.1.9Columnpmo6006AlmLineTempHighAlaPortnread-onlycurrentLine Trscv Temp High :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indicat…
1.3.6.1.4.1.20044.70.2.3.2.104.1.16Columnpmo6006AlmLineRxPwrLowAlaPortnread-onlycurrentLine Trscv Rx Power Low :This OID indicates that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indic…
1.3.6.1.4.1.20044.70.2.3.2.104.1.17Columnpmo6006AlmLineRxPwrHighAlaPortnread-onlycurrentLine Trscv Rx Power High :This OID indicates that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm ind…
1.3.6.1.4.1.20044.70.2.3.2.120Tablepmo6006AlmlineNetworkLaneAlarmWarning2Tablenot-accessiblecurrentList of pmo6006AlmlineNetworkLaneAlarmWarning2 Article
1.3.6.1.4.1.20044.70.2.3.2.120.1Rowpmo6006AlmlineNetworkLaneAlarmWarning2Entrynot-accessiblecurrentRow definition for the pmo6006AlmlineNetworkLaneAlarmWarning2 table
1.3.6.1.4.1.20044.70.2.3.2.120.1.1Columnpmo6006AlmlineNetworkLaneAlarmWarning2Indexread-onlycurrentIndex definition for the pmo6006AlmlineNetworkLaneAlarmWarning2 table
1.3.6.1.4.1.20044.70.2.3.2.120.1.2Columnpmo6006AlmLineTxPwLowWngPortnread-onlycurrentLine Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning in…
1.3.6.1.4.1.20044.70.2.3.2.120.1.3Columnpmo6006AlmLineTxPwrHighWngPortnread-onlycurrentLine Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.70.2.3.2.120.1.4Columnpmo6006AlmLineTxBiasLowWngPortnread-onlycurrentLine Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.70.2.3.2.120.1.5Columnpmo6006AlmLineTxBiasHighWngPortnread-onlycurrentLine Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.70.2.3.2.120.1.6Columnpmo6006AlmLineVccLowWngPortnread-onlycurrentLine Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.70.2.3.2.120.1.7Columnpmo6006AlmLineVccHighWngPortnread-onlycurrentLine Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Warn…
1.3.6.1.4.1.20044.70.2.3.2.120.1.8Columnpmo6006AlmLineTempLowWngPortnread-onlycurrentLine Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indicat…
1.3.6.1.4.1.20044.70.2.3.2.120.1.9Columnpmo6006AlmLineTempHighWngPortnread-onlycurrentLine Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning indic…
1.3.6.1.4.1.20044.70.2.3.2.120.1.16Columnpmo6006AlmLineRxPwrLowWngPortnread-onlycurrentLine Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning ind…
1.3.6.1.4.1.20044.70.2.3.2.120.1.17Columnpmo6006AlmLineRxPwrHighWngPortnread-onlycurrentLine Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning i…
1.3.6.1.4.1.20044.70.2.3.2.152Tablepmo6006AlmlineHostLaneFaultTablenot-accessiblecurrentList of pmo6006AlmlineHostLaneFault Article
1.3.6.1.4.1.20044.70.2.3.2.152.1Rowpmo6006AlmlineHostLaneFaultEntrynot-accessiblecurrentRow definition for the pmo6006AlmlineHostLaneFault table
1.3.6.1.4.1.20044.70.2.3.2.152.1.1Columnpmo6006AlmlineHostLaneFaultIndexread-onlycurrentIndex definition for the pmo6006AlmlineHostLaneFault table
1.3.6.1.4.1.20044.70.2.3.2.152.1.2Columnpmo6006AlmLineInputLossOfSignalPortnread-onlycurrentOPS2e DLOS-P :This OID indicates a Loss of Signal is detected on the Line Trscv<Help> This alarm indicates if an Optical Path Break has been detected on the li…
1.3.6.1.4.1.20044.70.2.3.2.152.1.3Columnpmo6006AlmLineLossOfFramePortnread-onlycurrentOTU2e - DLOF :This OID indicates the module is not aligned with the incoming Line signal<Help> This alarm indicates if a Loss Of Frame has been detected on the…
1.3.6.1.4.1.20044.70.2.3.2.152.1.4Columnpmo6006AlmLineSmBdiInsertedPortnread-onlycurrentOTU2e IBDI :This OID indicates a SM Backward Defect Indication is inserted on the outgoing Line signal<Help> This alarm indicates if a Backward Defect Indicati…
1.3.6.1.4.1.20044.70.2.3.2.152.1.5Columnpmo6006AlmLineSmBdiDetectedPortnread-onlycurrentOTU2e DBDI :This OID indicates a SM Backward Defect Indication is detected on the incoming Line signal<Help> This alarm indicates if a Backward Defect Indicati…
1.3.6.1.4.1.20044.70.2.3.2.152.1.8Columnpmo6006AlmOtu2eDdegPortnread-onlycurrentOTU2e DDEG :This OID indicates that a Signal Degrade has been detected on line port <Help> This alarm indicates if a Signal Degrade has been detected upon thre…
1.3.6.1.4.1.20044.70.2.3.2.152.1.9Columnpmo6006AlmClientOtu2eDtimPortnread-onlycurrentOTU2e DTIM :This OID indicates that a Trace Identifier Mismatch has been detected on line port <Help> This alarm indicates if a Trace Idenifier Mismatch has be…
1.3.6.1.4.1.20044.70.2.3.2.152.1.12Columnpmo6006AlmLineOchr2eDlosPPortnread-onlycurrentOchr2e - DLOS-P :This OID indicates that a Transmitter failure has been detected on line port <Help> This alarm indicates if a Transmitter Failure has been det…
1.3.6.1.4.1.20044.70.2.3.2.152.1.16Columnpmo6006AlmLineOtu2eDssfPortnread-onlycurrentOTU2e DSSF :This OID indicates that a Server Signal failure has been detected on line port <Help> This alarm indicates if a Server Signal Failure has been dete…
1.3.6.1.4.1.20044.70.2.3.2.152.1.17Columnpmo6006AlmLineOtu2eDlomPortnread-onlycurrentOTU2e DLOM :This OID indicates that a Loss Of Multiframe has been detected on line port <Help> This alarm indicates if a Loss Of Multiframe has been detected o…
1.3.6.1.4.1.20044.70.2.3.3Nodepmo6006AlmLineCrit
1.3.6.1.4.1.20044.70.2.3.3.24Tablepmo6006AlmsynthAlmLineTablenot-accessiblecurrentList of pmo6006AlmsynthAlmLine Article
1.3.6.1.4.1.20044.70.2.3.3.24.1Rowpmo6006AlmsynthAlmLineEntrynot-accessiblecurrentRow definition for the pmo6006AlmsynthAlmLine table
1.3.6.1.4.1.20044.70.2.3.3.24.1.1Columnpmo6006AlmsynthAlmLineIndexread-onlycurrentIndex definition for the pmo6006AlmsynthAlmLine table
1.3.6.1.4.1.20044.70.2.3.3.24.1.2Columnpmo6006AlmLineSfpAbsentPortnread-onlycurrentLine Optical Module Absent :This OID indicates that the line optical interface is not present. <Help> This alarm indicates if the line transceiver is not plugg…
1.3.6.1.4.1.20044.70.2.3.3.24.1.3Columnpmo6006AlmLineDdmAbsentPortnread-onlycurrentLine Optical Module Ready :This OID indicates that the optical interface is not operational. <Help> This status indicates if the line transceiver has been corr…
1.3.6.1.4.1.20044.70.2.3.3.24.1.5Columnpmo6006AlmLineHwFailPortnread-onlycurrentLine Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Help> This alarm indicates a failure on line port, most pr…
1.3.6.1.4.1.20044.70.2.3.3.24.1.6Columnpmo6006AlmLineTxOffPortnread-onlycurrentLine Optical Module Laser Shutdown :This OID indicates the Line transceiver laser is shutdown <Help> This status indicates if the Line transceiver laser is shu…
1.3.6.1.4.1.20044.70.2.3.3.24.1.7Columnpmo6006AlmLineLocalOosPortnread-onlycurrentLine Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service…
1.3.6.1.4.1.20044.70.2.3.3.24.1.9Columnpmo6006AlmUpRdiInsPortnread-onlycurrentMS-RDI/L-RDI Inserted On Line :This OID indicates an upstream MS-RDI/L-RDI has been inserted in the outgoing 10 Gb/s SDH/SONET signal. <Help> This status indic…
1.3.6.1.4.1.20044.70.2.3.3.24.1.10Columnpmo6006AlmLineDdmWarningPortnread-onlycurrentWarning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Warning has…
1.3.6.1.4.1.20044.70.2.3.3.24.1.11Columnpmo6006AlmLineDdmAlmPortnread-onlycurrentAlarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Alarm has been…
1.3.6.1.4.1.20044.70.2.3.3.24.1.13Columnpmo6006AlmLineFailPortnread-onlycurrentLine Port Failure :This OID indicates a failure on the line port <Help> This alarm indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipm…
1.3.6.1.4.1.20044.70.3Nodepmo6006measures
1.3.6.1.4.1.20044.70.3.1Nodepmo6006MesrOther
1.3.6.1.4.1.20044.70.3.2Nodepmo6006MesrClient
1.3.6.1.4.1.20044.70.3.2.16Tablepmo6006MesrclientTempTablenot-accessiblecurrentList of pmo6006MesrclientTemp Article
1.3.6.1.4.1.20044.70.3.2.16.1Rowpmo6006MesrclientTempEntrynot-accessiblecurrentRow definition for the pmo6006MesrclientTemp table
1.3.6.1.4.1.20044.70.3.2.16.1.1Columnpmo6006MesrclientTempIndexread-onlycurrentIndex definition for the pmo6006MesrclientTemp table
1.3.6.1.4.1.20044.70.3.2.16.1.2Columnpmo6006MesrclientTempPortnread-onlycurrentClient SFP Temperature :This OID gives the Laser temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = …
1.3.6.1.4.1.20044.70.3.2.32Tablepmo6006MesrclientTxBiasTablenot-accessiblecurrentList of pmo6006MesrclientTxBias Article
1.3.6.1.4.1.20044.70.3.2.32.1Rowpmo6006MesrclientTxBiasEntrynot-accessiblecurrentRow definition for the pmo6006MesrclientTxBias table
1.3.6.1.4.1.20044.70.3.2.32.1.1Columnpmo6006MesrclientTxBiasIndexread-onlycurrentIndex definition for the pmo6006MesrclientTxBias table
1.3.6.1.4.1.20044.70.3.2.32.1.2Columnpmo6006MesrclientTxBiasPortnread-onlycurrentClient SFP Laser Bias :This OID gives the Laser bias value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit =…
1.3.6.1.4.1.20044.70.3.2.48Tablepmo6006MesrclientTxPwrTablenot-accessiblecurrentList of pmo6006MesrclientTxPwr Article
1.3.6.1.4.1.20044.70.3.2.48.1Rowpmo6006MesrclientTxPwrEntrynot-accessiblecurrentRow definition for the pmo6006MesrclientTxPwr table
1.3.6.1.4.1.20044.70.3.2.48.1.1Columnpmo6006MesrclientTxPwrIndexread-onlycurrentIndex definition for the pmo6006MesrclientTxPwr table
1.3.6.1.4.1.20044.70.3.2.48.1.2Columnpmo6006MesrclientTxPwrPortnread-onlycurrentClient SFP Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-4…
1.3.6.1.4.1.20044.70.3.2.64Tablepmo6006MesrclientRxPwrTablenot-accessiblecurrentList of pmo6006MesrclientRxPwr Article
1.3.6.1.4.1.20044.70.3.2.64.1Rowpmo6006MesrclientRxPwrEntrynot-accessiblecurrentRow definition for the pmo6006MesrclientRxPwr table
1.3.6.1.4.1.20044.70.3.2.64.1.1Columnpmo6006MesrclientRxPwrIndexread-onlycurrentIndex definition for the pmo6006MesrclientRxPwr table
1.3.6.1.4.1.20044.70.3.2.64.1.2Columnpmo6006MesrclientRxPwrPortnread-onlycurrentClient SFP Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) …
1.3.6.1.4.1.20044.70.3.3Nodepmo6006MesrLine
1.3.6.1.4.1.20044.70.3.3.80Tablepmo6006MesrlineTxPwrTablenot-accessiblecurrentList of pmo6006MesrlineTxPwr Article
1.3.6.1.4.1.20044.70.3.3.80.1Rowpmo6006MesrlineTxPwrEntrynot-accessiblecurrentRow definition for the pmo6006MesrlineTxPwr table
1.3.6.1.4.1.20044.70.3.3.80.1.1Columnpmo6006MesrlineTxPwrIndexread-onlycurrentIndex definition for the pmo6006MesrlineTxPwr table
1.3.6.1.4.1.20044.70.3.3.80.1.2Columnpmo6006MesrlineTxPwrPortnread-onlycurrentLine Optical Module Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power …
1.3.6.1.4.1.20044.70.3.3.96Tablepmo6006MesrlineTempTablenot-accessiblecurrentList of pmo6006MesrlineTemp Article
1.3.6.1.4.1.20044.70.3.3.96.1Rowpmo6006MesrlineTempEntrynot-accessiblecurrentRow definition for the pmo6006MesrlineTemp table
1.3.6.1.4.1.20044.70.3.3.96.1.1Columnpmo6006MesrlineTempIndexread-onlycurrentIndex definition for the pmo6006MesrlineTemp table
1.3.6.1.4.1.20044.70.3.3.96.1.2Columnpmo6006MesrlineTempPortnread-onlycurrentLine Optical Module Temperature :This OID gives the Tx Laser Temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temp…
1.3.6.1.4.1.20044.70.3.3.112Tablepmo6006MesrlineTxBiasTablenot-accessiblecurrentList of pmo6006MesrlineTxBias Article
1.3.6.1.4.1.20044.70.3.3.112.1Rowpmo6006MesrlineTxBiasEntrynot-accessiblecurrentRow definition for the pmo6006MesrlineTxBias table
1.3.6.1.4.1.20044.70.3.3.112.1.1Columnpmo6006MesrlineTxBiasIndexread-onlycurrentIndex definition for the pmo6006MesrlineTxBias table
1.3.6.1.4.1.20044.70.3.3.112.1.2Columnpmo6006MesrlineTxBiasPortnread-onlycurrentLine Optical Module Laser Bias :This OID gives the Tx Laser Bias value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/50…
1.3.6.1.4.1.20044.70.3.3.128Tablepmo6006MesrlineRxPwrTablenot-accessiblecurrentList of pmo6006MesrlineRxPwr Article
1.3.6.1.4.1.20044.70.3.3.128.1Rowpmo6006MesrlineRxPwrEntrynot-accessiblecurrentRow definition for the pmo6006MesrlineRxPwr table
1.3.6.1.4.1.20044.70.3.3.128.1.1Columnpmo6006MesrlineRxPwrIndexread-onlycurrentIndex definition for the pmo6006MesrlineRxPwr table
1.3.6.1.4.1.20044.70.3.3.128.1.2Columnpmo6006MesrlineRxPwrPortnread-onlycurrentLine Optical Module Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(A…
1.3.6.1.4.1.20044.70.4Nodepmo6006counters
1.3.6.1.4.1.20044.70.4.1Nodepmo6006CntOther
1.3.6.1.4.1.20044.70.4.2Nodepmo6006CntClient
1.3.6.1.4.1.20044.70.4.2.64Tablepmo6006CntclientRemoteBipTablenot-accessiblecurrentList of pmo6006CntclientRemoteBip Article
1.3.6.1.4.1.20044.70.4.2.64.1Rowpmo6006CntclientRemoteBipEntrynot-accessiblecurrentRow definition for the pmo6006CntclientRemoteBip table
1.3.6.1.4.1.20044.70.4.2.64.1.1Columnpmo6006CntclientRemoteBipIndexread-onlycurrentIndex definition for the pmo6006CntclientRemoteBip table
1.3.6.1.4.1.20044.70.4.2.64.1.2Columnpmo6006CntclientRemoteBipValuePortnread-onlycurrentODU2e_Sk_pF_EBC :This counter is increased each time a BIP8 error is detected on the Client input stream <Help> This counter gives the number of BIP8 errors on…
1.3.6.1.4.1.20044.70.4.2.64.1.3Columnpmo6006CntclientRemoteBipErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the BIP8 error counter value is invalid on Port
1.3.6.1.4.1.20044.70.4.2.64.1.4Columnpmo6006CntclientRemoteBipOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a BIP8 error counter overload on Port
1.3.6.1.4.1.20044.70.4.2.96Tablepmo6006CntclientCbipCounterTablenot-accessiblecurrentList of pmo6006CntclientCbipCounter Article
1.3.6.1.4.1.20044.70.4.2.96.1Rowpmo6006CntclientCbipCounterEntrynot-accessiblecurrentRow definition for the pmo6006CntclientCbipCounter table
1.3.6.1.4.1.20044.70.4.2.96.1.1Columnpmo6006CntclientCbipCounterIndexread-onlycurrentIndex definition for the pmo6006CntclientCbipCounter table
1.3.6.1.4.1.20044.70.4.2.96.1.2Columnpmo6006CntclientCbipCounterValuePortnread-onlycurrentODU2e_Sk_pN_EBC :This counter is incremented each time a BI8P error is detected on the Client path <Help> This counter gives the number of BIP8 errors on the c…
1.3.6.1.4.1.20044.70.4.2.96.1.3Columnpmo6006CntclientCbipCounterErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the CBIP error counter value is invalid on Port
1.3.6.1.4.1.20044.70.4.2.96.1.4Columnpmo6006CntclientCbipCounterOverloadPortnread-onlycurrentClient CBIP Counter Overload :This OID when set indicates a CBIP error counter overload on Port
1.3.6.1.4.1.20044.70.4.3Nodepmo6006CntLine
1.3.6.1.4.1.20044.70.4.3.192Tablepmo6006CntlocalLineSmBip8ErrorCounterTablenot-accessiblecurrentList of pmo6006CntlocalLineSmBip8ErrorCounter Article
1.3.6.1.4.1.20044.70.4.3.192.1Rowpmo6006CntlocalLineSmBip8ErrorCounterEntrynot-accessiblecurrentRow definition for the pmo6006CntlocalLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.70.4.3.192.1.1Columnpmo6006CntlocalLineSmBip8ErrorCounterIndexread-onlycurrentIndex definition for the pmo6006CntlocalLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.70.4.3.192.1.2Columnpmo6006CntlocalLineSmBip8ErrorCounterValuePortnread-onlycurrentOTU2e_Sk_pN_EBC :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC <Help> This counter gives the current Bit Error Rate (residual SM…
1.3.6.1.4.1.20044.70.4.3.192.1.3Columnpmo6006CntlocalLineSmBip8ErrorCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the B1 error counter value is invalid on Port
1.3.6.1.4.1.20044.70.4.3.192.1.4Columnpmo6006CntlocalLineSmBip8ErrorCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a B1 error counter overload on Port
1.3.6.1.4.1.20044.70.4.3.200Tablepmo6006CntlocalLineFecCorrectedErrorsCounterTablenot-accessiblecurrentList of pmo6006CntlocalLineFecCorrectedErrorsCounter Article
1.3.6.1.4.1.20044.70.4.3.200.1Rowpmo6006CntlocalLineFecCorrectedErrorsCounterEntrynot-accessiblecurrentRow definition for the pmo6006CntlocalLineFecCorrectedErrorsCounter table
1.3.6.1.4.1.20044.70.4.3.200.1.1Columnpmo6006CntlocalLineFecCorrectedErrorsCounterIndexread-onlycurrentIndex definition for the pmo6006CntlocalLineFecCorrectedErrorsCounter table
1.3.6.1.4.1.20044.70.4.3.200.1.2Columnpmo6006CntlocalLineFecCorrectedErrorsCounterValuePortnread-onlycurrentOCh/OTU2e-Sk_pFECcorrErr :This OID gives the current Bit Error Rate before the Hard Decision FEC <Help> This counter gives the current Bit Error Rate before th…
1.3.6.1.4.1.20044.70.4.3.200.1.3Columnpmo6006CntlocalLineFecCorrectedErrorsCounterErrorPortnread-onlycurrentFEC Counter Error :This bit when set indicates the FEC corrected errors counter value is invalid on Line
1.3.6.1.4.1.20044.70.4.3.200.1.4Columnpmo6006CntlocalLineFecCorrectedErrorsCounterOverloadPortnread-onlycurrentFEC Counter Overload :This bit when set indicates a FEC corrected errors counter overload on Line
1.3.6.1.4.1.20044.70.4.3.208Tablepmo6006CntremoteLineSmBip8ErrorCounterTablenot-accessiblecurrentList of pmo6006CntremoteLineSmBip8ErrorCounter Article
1.3.6.1.4.1.20044.70.4.3.208.1Rowpmo6006CntremoteLineSmBip8ErrorCounterEntrynot-accessiblecurrentRow definition for the pmo6006CntremoteLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.70.4.3.208.1.1Columnpmo6006CntremoteLineSmBip8ErrorCounterIndexread-onlycurrentIndex definition for the pmo6006CntremoteLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.70.4.3.208.1.2Columnpmo6006CntremoteLineSmBip8ErrorCounterValuePortnread-onlycurrentOTU2e_Sk_pF_EBC :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC on the remote side <Help> This counter gives the current Bit Erro…
1.3.6.1.4.1.20044.70.4.3.208.1.3Columnpmo6006CntremoteLineSmBip8ErrorCounterErrorPortnread-onlycurrentRemote Counter Error :
1.3.6.1.4.1.20044.70.4.3.208.1.4Columnpmo6006CntremoteLineSmBip8ErrorCounterOverloadPortnread-onlycurrentRemote Counter Overload :
1.3.6.1.4.1.20044.70.4.3.216Tablepmo6006CntlineDfrmTimCntTablenot-accessiblecurrentList of pmo6006CntlineDfrmTimCnt Article
1.3.6.1.4.1.20044.70.4.3.216.1Rowpmo6006CntlineDfrmTimCntEntrynot-accessiblecurrentRow definition for the pmo6006CntlineDfrmTimCnt table
1.3.6.1.4.1.20044.70.4.3.216.1.1Columnpmo6006CntlineDfrmTimCntIndexread-onlycurrentIndex definition for the pmo6006CntlineDfrmTimCnt table
1.3.6.1.4.1.20044.70.4.3.216.1.2Columnpmo6006CntlineDfrmTimCntValuePortnread-onlycurrentLine Timer Counter :
1.3.6.1.4.1.20044.70.4.3.216.1.3Columnpmo6006CntlineDfrmTimCntErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.70.4.3.216.1.4Columnpmo6006CntlineDfrmTimCntOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.70.4.259Scalarpmo6006CntCountersResetread-writecurrentCounters Reset:This OID resets and restarts all the counters
1.3.6.1.4.1.20044.70.4.260Scalarpmo6006CntCountersStopread-writecurrentCounters stop:This OID stops all the counters
1.3.6.1.4.1.20044.70.6Nodepmo6006controlsWrite
1.3.6.1.4.1.20044.70.6.1Nodepmo6006CtrlOther
1.3.6.1.4.1.20044.70.6.1.1Nodepmo6006CtrlconfMgnt1
1.3.6.1.4.1.20044.70.6.1.1.1Scalarpmo6006CtrlConf1Load1read-writecurrentLoad Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM.
1.3.6.1.4.1.20044.70.6.1.1.2Scalarpmo6006CtrlConf2Load1read-writecurrentLoad Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM.
1.3.6.1.4.1.20044.70.6.1.1.10Scalarpmo6006CtrlConf2Flash1read-writecurrentWrite Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura…
1.3.6.1.4.1.20044.70.6.1.1.14Scalarpmo6006CtrlConf2Clear1read-writecurrentClear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o…
1.3.6.1.4.1.20044.70.6.1.4Nodepmo6006Ctrlsynth4
1.3.6.1.4.1.20044.70.6.1.4.1Scalarpmo6006CtrlCorrelatOnread-writecurrentEnable Alarm Correlation :This OID enables the alarm correlation in the PM.
1.3.6.1.4.1.20044.70.6.1.4.2Scalarpmo6006CtrlCorrelatOffread-writecurrentDisable Alarm Correlation :This OID disables the alarm correlation in the PM.
1.3.6.1.4.1.20044.70.6.1.5Nodepmo6006CtrlswMgnt
1.3.6.1.4.1.20044.70.6.1.5.2Scalarpmo6006CtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> …
1.3.6.1.4.1.20044.70.6.1.5.3Scalarpmo6006CtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th…
1.3.6.1.4.1.20044.70.6.1.5.5Scalarpmo6006CtrlLoadSwBank1read-writecurrentSet Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW…
1.3.6.1.4.1.20044.70.6.1.5.6Scalarpmo6006CtrlLoadSwBank2read-writecurrentSet Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S…
1.3.6.1.4.1.20044.70.6.1.6Nodepmo6006CtrlgwMgnt
1.3.6.1.4.1.20044.70.6.1.6.1Scalarpmo6006CtrlCurrentGwResetread-writecurrentActive Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting.
1.3.6.1.4.1.20044.70.6.1.6.5Scalarpmo6006CtrlLoadGwBank1read-writecurrentSet Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.70.6.1.6.6Scalarpmo6006CtrlLoadGwBank2read-writecurrentSet Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.70.6.1.6.7Scalarpmo6006CtrlLoadGwBank3read-writecurrentSet Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.70.6.1.6.8Scalarpmo6006CtrlLoadGwBank4read-writecurrentSet Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.70.6.1.192Nodepmo6006CtrlledTest
1.3.6.1.4.1.20044.70.6.1.192.1Scalarpmo6006CtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.70.6.1.192.2Scalarpmo6006CtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.70.6.1.192.3Scalarpmo6006CtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.70.6.2Nodepmo6006CtrlClient
1.3.6.1.4.1.20044.70.6.2.16Tablepmo6006CtrlaccessLoopTablenot-accessiblecurrentList of pmo6006CtrlaccessLoop Article
1.3.6.1.4.1.20044.70.6.2.16.1Rowpmo6006CtrlaccessLoopEntrynot-accessiblecurrentRow definition for the pmo6006CtrlaccessLoop table
1.3.6.1.4.1.20044.70.6.2.16.1.1Columnpmo6006CtrlaccessLoopIndexread-onlycurrentIndex definition for the pmo6006CtrlaccessLoop table
1.3.6.1.4.1.20044.70.6.2.16.1.2Columnpmo6006CtrlaccessLoopPortnread-writecurrentClient Facility Loopback :This OID, when set at '1' puts the client port in loopback, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. <Help…
1.3.6.1.4.1.20044.70.6.2.17Tablepmo6006CtrlclientLoopToLineTablenot-accessiblecurrentList of pmo6006CtrlclientLoopToLine Article
1.3.6.1.4.1.20044.70.6.2.17.1Rowpmo6006CtrlclientLoopToLineEntrynot-accessiblecurrentRow definition for the pmo6006CtrlclientLoopToLine table
1.3.6.1.4.1.20044.70.6.2.17.1.1Columnpmo6006CtrlclientLoopToLineIndexread-onlycurrentIndex definition for the pmo6006CtrlclientLoopToLine table
1.3.6.1.4.1.20044.70.6.2.17.1.2Columnpmo6006CtrlclientLoopToLinePortnread-writecurrentClient Terminal Loopback :This OID, when set, puts the client port in loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.<Help> This control ena…
1.3.6.1.4.1.20044.70.6.2.21Tablepmo6006CtrlcsfUpInsTablenot-accessiblecurrentList of pmo6006CtrlcsfUpIns Article
1.3.6.1.4.1.20044.70.6.2.21.1Rowpmo6006CtrlcsfUpInsEntrynot-accessiblecurrentRow definition for the pmo6006CtrlcsfUpIns table
1.3.6.1.4.1.20044.70.6.2.21.1.1Columnpmo6006CtrlcsfUpInsIndexread-onlycurrentIndex definition for the pmo6006CtrlcsfUpIns table
1.3.6.1.4.1.20044.70.6.2.21.1.2Columnpmo6006CtrlcsfUpInsPortnread-writecurrentClient Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo…
1.3.6.1.4.1.20044.70.6.2.22Tablepmo6006CtrlcaisDwInsTablenot-accessiblecurrentList of pmo6006CtrlcaisDwIns Article
1.3.6.1.4.1.20044.70.6.2.22.1Rowpmo6006CtrlcaisDwInsEntrynot-accessiblecurrentRow definition for the pmo6006CtrlcaisDwIns table
1.3.6.1.4.1.20044.70.6.2.22.1.1Columnpmo6006CtrlcaisDwInsIndexread-onlycurrentIndex definition for the pmo6006CtrlcaisDwIns table
1.3.6.1.4.1.20044.70.6.2.22.1.2Columnpmo6006CtrlcaisDwInsPortnread-writecurrentClient AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port
1.3.6.1.4.1.20044.70.6.2.23Tablepmo6006CtrlclientOciTablenot-accessiblecurrentList of pmo6006CtrlclientOci Article
1.3.6.1.4.1.20044.70.6.2.23.1Rowpmo6006CtrlclientOciEntrynot-accessiblecurrentRow definition for the pmo6006CtrlclientOci table
1.3.6.1.4.1.20044.70.6.2.23.1.1Columnpmo6006CtrlclientOciIndexread-onlycurrentIndex definition for the pmo6006CtrlclientOci table
1.3.6.1.4.1.20044.70.6.2.23.1.2Columnpmo6006CtrlclientOciPortnread-writecurrentODU2e-OCI :Label <Help> This control inserts a Client OCI
1.3.6.1.4.1.20044.70.6.2.24Tablepmo6006CtrlclientLckTablenot-accessiblecurrentList of pmo6006CtrlclientLck Article
1.3.6.1.4.1.20044.70.6.2.24.1Rowpmo6006CtrlclientLckEntrynot-accessiblecurrentRow definition for the pmo6006CtrlclientLck table
1.3.6.1.4.1.20044.70.6.2.24.1.1Columnpmo6006CtrlclientLckIndexread-onlycurrentIndex definition for the pmo6006CtrlclientLck table
1.3.6.1.4.1.20044.70.6.2.24.1.2Columnpmo6006CtrlclientLckPortnread-writecurrentODU2e-LCK :Label <Help> This control inserts a Client LCK
1.3.6.1.4.1.20044.70.6.2.25Tablepmo6006CtrlclientAisTablenot-accessiblecurrentList of pmo6006CtrlclientAis Article
1.3.6.1.4.1.20044.70.6.2.25.1Rowpmo6006CtrlclientAisEntrynot-accessiblecurrentRow definition for the pmo6006CtrlclientAis table
1.3.6.1.4.1.20044.70.6.2.25.1.1Columnpmo6006CtrlclientAisIndexread-onlycurrentIndex definition for the pmo6006CtrlclientAis table
1.3.6.1.4.1.20044.70.6.2.25.1.2Columnpmo6006CtrlclientAisPortnread-writecurrentODU2e-AIS :Label <Help> This control inserts a Client AIS
1.3.6.1.4.1.20044.70.6.2.26Tablepmo6006CtrlclientBdiTablenot-accessiblecurrentList of pmo6006CtrlclientBdi Article
1.3.6.1.4.1.20044.70.6.2.26.1Rowpmo6006CtrlclientBdiEntrynot-accessiblecurrentRow definition for the pmo6006CtrlclientBdi table
1.3.6.1.4.1.20044.70.6.2.26.1.1Columnpmo6006CtrlclientBdiIndexread-onlycurrentIndex definition for the pmo6006CtrlclientBdi table
1.3.6.1.4.1.20044.70.6.2.26.1.2Columnpmo6006CtrlclientBdiPortnread-writecurrentODU2e-BDI :Label <Help> This control inserts a Client BDI
1.3.6.1.4.1.20044.70.6.3Nodepmo6006CtrlLine
1.3.6.1.4.1.20044.70.6.3.64Tablepmo6006CtrlcommAccessLoopTablenot-accessiblecurrentList of pmo6006CtrlcommAccessLoop Article
1.3.6.1.4.1.20044.70.6.3.64.1Rowpmo6006CtrlcommAccessLoopEntrynot-accessiblecurrentRow definition for the pmo6006CtrlcommAccessLoop table
1.3.6.1.4.1.20044.70.6.3.64.1.1Columnpmo6006CtrlcommAccessLoopIndexread-onlycurrentIndex definition for the pmo6006CtrlcommAccessLoop table
1.3.6.1.4.1.20044.70.6.3.64.1.2Columnpmo6006CtrlcommAccessLoopPortnread-writecurrentLine Terminal Loopback :This OID, when set, puts the module in common access loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.<Help> This cont…
1.3.6.1.4.1.20044.70.6.3.66Tablepmo6006CtrllineLoopTablenot-accessiblecurrentList of pmo6006CtrllineLoop Article
1.3.6.1.4.1.20044.70.6.3.66.1Rowpmo6006CtrllineLoopEntrynot-accessiblecurrentRow definition for the pmo6006CtrllineLoop table
1.3.6.1.4.1.20044.70.6.3.66.1.1Columnpmo6006CtrllineLoopIndexread-onlycurrentIndex definition for the pmo6006CtrllineLoop table
1.3.6.1.4.1.20044.70.6.3.66.1.2Columnpmo6006CtrllineLoopPortnread-writecurrentLine Facility Loopback :This OID, when set at '1' puts the module in line loopback mode, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. Th…
1.3.6.1.4.1.20044.70.6.3.69Tablepmo6006CtrlfecDisableTablenot-accessiblecurrentList of pmo6006CtrlfecDisable Article
1.3.6.1.4.1.20044.70.6.3.69.1Rowpmo6006CtrlfecDisableEntrynot-accessiblecurrentRow definition for the pmo6006CtrlfecDisable table
1.3.6.1.4.1.20044.70.6.3.69.1.1Columnpmo6006CtrlfecDisableIndexread-onlycurrentIndex definition for the pmo6006CtrlfecDisable table
1.3.6.1.4.1.20044.70.6.3.69.1.2Columnpmo6006CtrlfecDisablePortnread-writecurrentForward Error Correction Inhibition :This OID, when set, inhibits the Forward Error Correction feature on the line input <Help> This control enables/disables t…
1.3.6.1.4.1.20044.70.6.3.70Tablepmo6006CtrllineBdiTablenot-accessiblecurrentList of pmo6006CtrllineBdi Article
1.3.6.1.4.1.20044.70.6.3.70.1Rowpmo6006CtrllineBdiEntrynot-accessiblecurrentRow definition for the pmo6006CtrllineBdi table
1.3.6.1.4.1.20044.70.6.3.70.1.1Columnpmo6006CtrllineBdiIndexread-onlycurrentIndex definition for the pmo6006CtrllineBdi table
1.3.6.1.4.1.20044.70.6.3.70.1.2Columnpmo6006CtrllineBdiPortnread-writecurrentOTU2e-BDI :Label <Help> This control inserts a Line BDI
1.3.6.1.4.1.20044.70.7Nodepmo6006ri
1.3.6.1.4.1.20044.70.7.1Nodepmo6006riTable
1.3.6.1.4.1.20044.70.7.1.1Tablepmo6006RinvSfpTablenot-accessiblecurrentList of the SFPs on the selected module
1.3.6.1.4.1.20044.70.7.1.1.1Rowpmo6006RinvSfpEntrynot-accessiblecurrentRow definition for the SFP table
1.3.6.1.4.1.20044.70.7.1.1.1.1Columnpmo6006RinvSfpIndexread-onlycurrentIndex for SFP table
1.3.6.1.4.1.20044.70.7.1.1.1.2Columnpmo6006Rinvsfpread-onlycurrentInventory for the SFP: This OID contains the inventory for the SFP
1.3.6.1.4.1.20044.70.7.1.2Tablepmo6006RinvLineTablenot-accessiblecurrentList of the SFPs on the selected module
1.3.6.1.4.1.20044.70.7.1.2.1Rowpmo6006RinvLineEntrynot-accessiblecurrentRow definition for the SFP table
1.3.6.1.4.1.20044.70.7.1.2.1.1Columnpmo6006RinvLineIndexread-onlycurrentIndex for SFP table
1.3.6.1.4.1.20044.70.7.1.2.1.2Columnpmo6006RinvxfpLineread-onlycurrentInventory for the XFP: This OID contains the inventory for the XFP
1.3.6.1.4.1.20044.70.7.2Scalarpmo6006RinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.70.7.3Scalarpmo6006RinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.70.7.4Scalarpmo6006RinvModulePlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.70.7.5Scalarpmo6006RinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.70.7.6Scalarpmo6006RinvGwPlatformread-onlycurrentGW platform description: This OID contains the description of the Gateware platform.
1.3.6.1.4.1.20044.70.8Nodepmo6006download
1.3.6.1.4.1.20044.70.8.1Nodepmo6006DwlOther
1.3.6.1.4.1.20044.70.8.1.0Nodepmo6006DwlrestartProcess
1.3.6.1.4.1.20044.70.8.1.0.1Scalarpmo6006DwlWarmRestartProcessedread-onlycurrentWarm Restart :This OID indicates that the module last restart was a Warm RESTART
1.3.6.1.4.1.20044.70.8.1.0.2Scalarpmo6006DwlColdRestartProcessedread-onlycurrentCold Restart :This OID indicates that the module last restart was a Cold RESTART
1.3.6.1.4.1.20044.70.8.1.1Nodepmo6006DwlswBanksUsed
1.3.6.1.4.1.20044.70.8.1.1.1Scalarpmo6006DwlSwBank1Usedread-onlycurrentSW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby
1.3.6.1.4.1.20044.70.8.1.1.2Scalarpmo6006DwlSwBank2Usedread-onlycurrentSW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby
1.3.6.1.4.1.20044.70.8.1.1.5Scalarpmo6006DwlSwBank1Notemptyread-onlycurrentSW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package
1.3.6.1.4.1.20044.70.8.1.1.6Scalarpmo6006DwlSwBank2Notemptyread-onlycurrentSW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package
1.3.6.1.4.1.20044.70.8.1.2Nodepmo6006DwlgwBanksUsed
1.3.6.1.4.1.20044.70.8.1.2.1Scalarpmo6006DwlGwBank1Usedread-onlycurrentGW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby
1.3.6.1.4.1.20044.70.8.1.2.2Scalarpmo6006DwlGwBank2Usedread-onlycurrentGW bank 2 active :This OID indicates the module is working on GW bank 2
1.3.6.1.4.1.20044.70.8.1.2.3Scalarpmo6006DwlGwBank3Usedread-onlycurrentGW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby
1.3.6.1.4.1.20044.70.8.1.2.4Scalarpmo6006DwlGwBank4Usedread-onlycurrentGW bank 4 active :This OID indicates the module is working on GW bank 4
1.3.6.1.4.1.20044.70.8.1.2.5Scalarpmo6006DwlGwBank1Notemptyread-onlycurrentGW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package
1.3.6.1.4.1.20044.70.8.1.2.6Scalarpmo6006DwlGwBank2Notemptyread-onlycurrentGW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2
1.3.6.1.4.1.20044.70.8.1.2.7Scalarpmo6006DwlGwBank3Notemptyread-onlycurrentGW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package
1.3.6.1.4.1.20044.70.8.1.2.8Scalarpmo6006DwlGwBank4Notemptyread-onlycurrentGW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4
1.3.6.1.4.1.20044.70.8.2Nodepmo6006DwlClient
1.3.6.1.4.1.20044.70.8.3Nodepmo6006DwlLine
1.3.6.1.4.1.20044.70.9Nodepmo6006Config
1.3.6.1.4.1.20044.70.9.1Nodepmo6006CfgStartup
1.3.6.1.4.1.20044.70.9.1.1Tablepmo6006CfgClientStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.70.9.1.1.1Rowpmo6006CfgClientStartupEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.70.9.1.1.1.1Columnpmo6006CfgClientStartupIndexread-onlycurrentIndex definition for the clientStartup table
1.3.6.1.4.1.20044.70.9.1.1.1.3Columnpmo6006CfgSystConfPortPortnread-writecurrentDefault Settings on Client Port :This register configures the default initialisation settings on the port.
1.3.6.1.4.1.20044.70.9.1.1.1.4Columnpmo6006CfgNetConfPortPortnread-writecurrentDefault Settings on Client Port :This register configures the default initialisation settings on the port.
1.3.6.1.4.1.20044.70.9.1.1.1.14Columnpmo6006CfgOptionsPortPortnread-writecurrentDefault Options on Client Port :This register configures the default options on the port.
1.3.6.1.4.1.20044.70.9.1.2Tablepmo6006CfgLinexr1StartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.70.9.1.2.1Rowpmo6006CfgLinexr1StartupEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.70.9.1.2.1.1Columnpmo6006CfgLinexr1StartupIndexread-onlycurrentIndex definition for the linexr1Startup table
1.3.6.1.4.1.20044.70.9.1.2.1.3Columnpmo6006CfgSystConfLinePortnread-writecurrentDefault Settings on Line :This register configures the default initialisation settings on Line
1.3.6.1.4.1.20044.70.9.1.2.1.14Columnpmo6006CfgOptionsLinePortnread-writecurrentDefault Options on Line :This register configures the default options on the line
1.3.6.1.4.1.20044.70.9.1.3Tablepmo6006CfgOtxtlhTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.70.9.1.3.1Rowpmo6006CfgOtxtlhEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.70.9.1.3.1.1Columnpmo6006CfgOtxtlhIndexread-onlycurrentIndex definition for the otxtlh table
1.3.6.1.4.1.20044.70.9.1.3.1.3Columnpmo6006CfgLineControlsPortnread-writedeprecatedDefault Line settings :This register configures the start-up settings on the ports
1.3.6.1.4.1.20044.70.9.1.3.1.6Columnpmo6006CfgLinePwrLaserPortnread-writecurrentDefault Line output Power :This register configures the start-up output power of the client transceiver (Unit = dBm)
1.3.6.1.4.1.20044.70.9.1.3.1.7Columnpmo6006CfgLineFCurrentPortnread-writecurrentDefault Line transceiver Channel :This register configures the start-up laser channel of the client transceiver
1.3.6.1.4.1.20044.70.9.1.3.1.8Columnpmo6006CfgLineGridCurrentPortnread-writecurrentDefault Line transceiver Grid :This register configures the start-up laser grid of the client transceiver
1.3.6.1.4.1.20044.70.9.1.3.1.9Columnpmo6006CfgLineFoPortnread-writecurrentDefault Line first Frequency :This register configures the start-up first frequency of the client transceiver
1.3.6.1.4.1.20044.70.9.2Nodepmo6006CfgLabels
1.3.6.1.4.1.20044.70.9.2.1Tablepmo6006CfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.70.9.2.1.1Rowpmo6006CfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.70.9.2.1.1.1Columnpmo6006CfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.70.9.2.1.1.3Columnpmo6006CfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.70.9.2.2Tablepmo6006CfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.70.9.2.2.1Rowpmo6006CfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.70.9.2.2.1.1Columnpmo6006CfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.70.9.2.2.1.3Columnpmo6006CfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.70.9.3Nodepmo6006CfgOther
1.3.6.1.4.1.20044.70.9.3.1Nodepmo6006tablemoduleOther
1.3.6.1.4.1.20044.70.9.3.1.2Scalarpmo6006Cfgmoderead-writecurrentDefault settings on Module :This register selects the configuration mode of the module
1.3.6.1.4.1.20044.70.9.4Nodepmo6006CfgOdu2Clienta
1.3.6.1.4.1.20044.70.9.4.1Tablepmo6006CfgClientStartupOduTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.70.9.4.1.1Rowpmo6006CfgClientStartupOduEntrynot-accessiblecurrentRow definition for the odu2Clienta table
1.3.6.1.4.1.20044.70.9.4.1.1.1Columnpmo6006CfgClientStartupOduIndexread-onlycurrentIndex definition for the clientStartupOdu table
1.3.6.1.4.1.20044.70.9.4.1.1.3Columnpmo6006CfgOdu2ReserveLsbPortnread-writecurrent:
1.3.6.1.4.1.20044.70.9.4.1.1.4Columnpmo6006CfgOdu2DegthresholdPortnread-writecurrentODU2 Degrade Threshold :
1.3.6.1.4.1.20044.70.9.4.1.1.5Columnpmo6006CfgOdu2DegmPortnread-writecurrentODU2 Degrade Confirmation :
1.3.6.1.4.1.20044.70.9.4.1.1.6Columnpmo6006CfgOdu2SettingsPortnread-writecurrentODU2 Settings :
1.3.6.1.4.1.20044.70.9.5Nodepmo6006CfgOtu2Line
1.3.6.1.4.1.20044.70.9.5.1Tablepmo6006CfgLinexStartupOtuTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.70.9.5.1.1Rowpmo6006CfgLinexStartupOtuEntrynot-accessiblecurrentRow definition for the otu2Line table
1.3.6.1.4.1.20044.70.9.5.1.1.1Columnpmo6006CfgLinexStartupOtuIndexread-onlycurrentIndex definition for the linexStartupOtu table
1.3.6.1.4.1.20044.70.9.5.1.1.3Columnpmo6006CfgOtu2ReserveMsbPortnread-writecurrent:
1.3.6.1.4.1.20044.70.9.5.1.1.4Columnpmo6006CfgOtu2DegthresholdPortnread-writecurrentOTU2 Degrade Threshold :
1.3.6.1.4.1.20044.70.9.5.1.1.5Columnpmo6006CfgOtu2DegmPortnread-writecurrentOTU2 Degrade Confirmation :
1.3.6.1.4.1.20044.70.9.5.1.1.6Columnpmo6006CfgOtu2SettingsPortnread-writecurrentOTU2 Settings :
1.3.6.1.4.1.20044.70.9.6Nodepmo6006CfgSapiTxClient
1.3.6.1.4.1.20044.70.9.6.1Tablepmo6006CfgClientSapiTxOduTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.70.9.6.1.1Rowpmo6006CfgClientSapiTxOduEntrynot-accessiblecurrentRow definition for the sapiTxClient table
1.3.6.1.4.1.20044.70.9.6.1.1.1Columnpmo6006CfgClientSapiTxOduIndexread-onlycurrentIndex definition for the clientSapiTxOdu table
1.3.6.1.4.1.20044.70.9.6.1.1.3Columnpmo6006CfgClientSapiTxSetupPortnread-writecurrentClient Transmitted SAPI :This register defines the value of the transmitted Trace Identifier on the line output
1.3.6.1.4.1.20044.70.9.7Nodepmo6006CfgSapiExpClient
1.3.6.1.4.1.20044.70.9.7.1Tablepmo6006CfgClientSapiExpOduTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.70.9.7.1.1Rowpmo6006CfgClientSapiExpOduEntrynot-accessiblecurrentRow definition for the sapiExpClient table
1.3.6.1.4.1.20044.70.9.7.1.1.1Columnpmo6006CfgClientSapiExpOduIndexread-onlycurrentIndex definition for the clientSapiExpOdu table
1.3.6.1.4.1.20044.70.9.7.1.1.3Columnpmo6006CfgClientSapiExpSetupPortnread-writecurrentClient Expected SAPI :This register defines the value of the expected Trace Identifier on the line input
1.3.6.1.4.1.20044.70.9.8Nodepmo6006CfgSapiAccClient
1.3.6.1.4.1.20044.70.9.8.1Tablepmo6006CfgClientSapiAccOduTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.70.9.8.1.1Rowpmo6006CfgClientSapiAccOduEntrynot-accessiblecurrentRow definition for the sapiAccClient table
1.3.6.1.4.1.20044.70.9.8.1.1.1Columnpmo6006CfgClientSapiAccOduIndexread-onlycurrentIndex definition for the clientSapiAccOdu table
1.3.6.1.4.1.20044.70.9.8.1.1.3Columnpmo6006CfgClientSapiAccSetupPortnread-writedeprecatedClient Accepted SAPI :This register defines the value of the accepted Trace Identifier on the line input
1.3.6.1.4.1.20044.70.9.9Nodepmo6006CfgDapiTxClient
1.3.6.1.4.1.20044.70.9.9.1Tablepmo6006CfgClientDapiTxOduTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.70.9.9.1.1Rowpmo6006CfgClientDapiTxOduEntrynot-accessiblecurrentRow definition for the dapiTxClient table
1.3.6.1.4.1.20044.70.9.9.1.1.1Columnpmo6006CfgClientDapiTxOduIndexread-onlycurrentIndex definition for the clientDapiTxOdu table
1.3.6.1.4.1.20044.70.9.9.1.1.3Columnpmo6006CfgClientDapiTxSetupPortnread-writecurrentClient Transmitted DAPI :This register defines the value of the transmitted Trace Identifier on the line output
1.3.6.1.4.1.20044.70.9.10Nodepmo6006CfgDapiExpClient
1.3.6.1.4.1.20044.70.9.10.1Tablepmo6006CfgClientDapiExpOduTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.70.9.10.1.1Rowpmo6006CfgClientDapiExpOduEntrynot-accessiblecurrentRow definition for the dapiExpClient table
1.3.6.1.4.1.20044.70.9.10.1.1.1Columnpmo6006CfgClientDapiExpOduIndexread-onlycurrentIndex definition for the clientDapiExpOdu table
1.3.6.1.4.1.20044.70.9.10.1.1.3Columnpmo6006CfgClientDapiExpSetupPortnread-writecurrentClient Expected DAPI :This register defines the value of the expected Trace Identifier on the line input
1.3.6.1.4.1.20044.70.9.11Nodepmo6006CfgDapiAccClient
1.3.6.1.4.1.20044.70.9.11.1Tablepmo6006CfgClientDapiAccOduTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.70.9.11.1.1Rowpmo6006CfgClientDapiAccOduEntrynot-accessiblecurrentRow definition for the dapiAccClient table
1.3.6.1.4.1.20044.70.9.11.1.1.1Columnpmo6006CfgClientDapiAccOduIndexread-onlycurrentIndex definition for the clientDapiAccOdu table
1.3.6.1.4.1.20044.70.9.11.1.1.3Columnpmo6006CfgClientDapiAccSetupPortnread-writedeprecatedClient Accepted DAPI :This register defines the value of the accepted Trace Identifier on the line input
1.3.6.1.4.1.20044.70.9.12Nodepmo6006CfgSapiTxLine
1.3.6.1.4.1.20044.70.9.12.1Tablepmo6006CfgLineSapiTxOtuTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.70.9.12.1.1Rowpmo6006CfgLineSapiTxOtuEntrynot-accessiblecurrentRow definition for the sapiTxLine table
1.3.6.1.4.1.20044.70.9.12.1.1.1Columnpmo6006CfgLineSapiTxOtuIndexread-onlycurrentIndex definition for the lineSapiTxOtu table
1.3.6.1.4.1.20044.70.9.12.1.1.3Columnpmo6006CfgLineSapiTxSetupPortnread-writecurrentLine Transmitted SAPI :This register defines the value of the transmitted Trace Identifier on the line output
1.3.6.1.4.1.20044.70.9.13Nodepmo6006CfgSapiExpLine
1.3.6.1.4.1.20044.70.9.13.1Tablepmo6006CfgLineSapiExpOtuTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.70.9.13.1.1Rowpmo6006CfgLineSapiExpOtuEntrynot-accessiblecurrentRow definition for the sapiExpLine table
1.3.6.1.4.1.20044.70.9.13.1.1.1Columnpmo6006CfgLineSapiExpOtuIndexread-onlycurrentIndex definition for the lineSapiExpOtu table
1.3.6.1.4.1.20044.70.9.13.1.1.3Columnpmo6006CfgLineSapiExpSetupPortnread-writecurrentLine Expected SAPI :This register defines the value of the expected Trace Identifier on the line input
1.3.6.1.4.1.20044.70.9.14Nodepmo6006CfgSapiAccLine
1.3.6.1.4.1.20044.70.9.14.1Tablepmo6006CfgLineSapiAccOtuTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.70.9.14.1.1Rowpmo6006CfgLineSapiAccOtuEntrynot-accessiblecurrentRow definition for the sapiAccLine table
1.3.6.1.4.1.20044.70.9.14.1.1.1Columnpmo6006CfgLineSapiAccOtuIndexread-onlycurrentIndex definition for the lineSapiAccOtu table
1.3.6.1.4.1.20044.70.9.14.1.1.3Columnpmo6006CfgLineSapiAccSetupPortnread-writedeprecatedLine Accepted SAPI :This register defines the value of the accepted Trace Identifier on the line input
1.3.6.1.4.1.20044.70.9.15Nodepmo6006CfgDapiTxLine
1.3.6.1.4.1.20044.70.9.15.1Tablepmo6006CfgLineDapiTxOtuTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.70.9.15.1.1Rowpmo6006CfgLineDapiTxOtuEntrynot-accessiblecurrentRow definition for the dapiTxLine table
1.3.6.1.4.1.20044.70.9.15.1.1.1Columnpmo6006CfgLineDapiTxOtuIndexread-onlycurrentIndex definition for the lineDapiTxOtu table
1.3.6.1.4.1.20044.70.9.15.1.1.3Columnpmo6006CfgLineDapiTxSetupPortnread-writecurrentLine Transmitted DAPI :This register defines the value of the transmitted Trace Identifier on the line output
1.3.6.1.4.1.20044.70.9.16Nodepmo6006CfgDapiExpLine
1.3.6.1.4.1.20044.70.9.16.1Tablepmo6006CfgLineDapiExpOtuTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.70.9.16.1.1Rowpmo6006CfgLineDapiExpOtuEntrynot-accessiblecurrentRow definition for the dapiExpLine table
1.3.6.1.4.1.20044.70.9.16.1.1.1Columnpmo6006CfgLineDapiExpOtuIndexread-onlycurrentIndex definition for the lineDapiExpOtu table
1.3.6.1.4.1.20044.70.9.16.1.1.3Columnpmo6006CfgLineDapiExpSetupPortnread-writecurrentLine Expected DAPI :This register defines the value of the expected Trace Identifier on the line input
1.3.6.1.4.1.20044.70.9.17Nodepmo6006CfgDapiAccLine
1.3.6.1.4.1.20044.70.9.17.1Tablepmo6006CfgLineDapiAccOtuTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.70.9.17.1.1Rowpmo6006CfgLineDapiAccOtuEntrynot-accessiblecurrentRow definition for the dapiAccLine table
1.3.6.1.4.1.20044.70.9.17.1.1.1Columnpmo6006CfgLineDapiAccOtuIndexread-onlycurrentIndex definition for the lineDapiAccOtu table
1.3.6.1.4.1.20044.70.9.17.1.1.3Columnpmo6006CfgLineDapiAccSetupPortnread-writedeprecatedLine Accepted DAPI :This register defines the value of the accepted Trace Identifier on the line input
1.3.6.1.4.1.20044.70.9.18Nodepmo6006CfgStartuptablefive
1.3.6.1.4.1.20044.70.9.18.1Tablepmo6006CfgOtxtlhcapabilitiesTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.70.9.18.1.1Rowpmo6006CfgOtxtlhcapabilitiesEntrynot-accessiblecurrentRow definition for the startuptablefive table
1.3.6.1.4.1.20044.70.9.18.1.1.1Columnpmo6006CfgOtxtlhcapabilitiesIndexread-onlycurrentIndex definition for the otxtlhcapabilities table
1.3.6.1.4.1.20044.70.9.18.1.1.3Columnpmo6006CfgComponentTypePortnread-onlycurrentComponent parameters :This OID defines the component parameters
1.3.6.1.4.1.20044.70.9.18.1.1.4Columnpmo6006CfgMiscellaneousPortnread-onlycurrentMiscellaneous default settings :This OID defines the miscellaneous parameters
1.3.6.1.4.1.20044.70.9.18.1.1.5Columnpmo6006CfgFirstChannelPortnread-onlycurrentNumber of the first channel of the component :This OID defines the first channel number of the PM
1.3.6.1.4.1.20044.70.9.18.1.1.6Columnpmo6006CfgLastChannelPortnread-onlycurrentNumber of the last channel of the component :This OID defines the last channel number of the PM
1.3.6.1.4.1.20044.70.9.18.1.1.7Columnpmo6006CfgGridPortnread-onlycurrentGrid value of the component :This OID defines the grid of the PM
1.3.6.1.4.1.20044.70.9.257Scalarpmo6006CfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.70.10Nodepmo6006traps
1.3.6.1.4.1.20044.70.10.2Scalarpmo6006trapPortNumberread-onlycurrentLast port which generates a trap
1.3.6.1.4.1.20044.70.10.3Scalarpmo6006trapLineNumberread-onlycurrentLast Line which generates a trap
1.3.6.1.4.1.20044.70.10.4Scalarpmo6006trapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.70.10.30Notificationpmo6006LineTrapNotUrgentGoesOncurrentNot urgent Line default is activated
1.3.6.1.4.1.20044.70.10.31Notificationpmo6006LineTrapNotUrgentGoesOffcurrentNot urgent Line default disappeared
1.3.6.1.4.1.20044.70.10.32Notificationpmo6006LineTrapUrgentGoesOncurrentUrgent Line default is activated
1.3.6.1.4.1.20044.70.10.33Notificationpmo6006LineTrapUrgentGoesOffcurrentUrgent Line default disappeared
1.3.6.1.4.1.20044.70.10.34Notificationpmo6006LineTrapCritGoesOncurrentCritical Line default is activated
1.3.6.1.4.1.20044.70.10.35Notificationpmo6006LineTrapCritGoesOffcurrentCritical Line default disappeared
1.3.6.1.4.1.20044.70.10.40Notificationpmo6006ClientTrapNotUrgentGoesOncurrentNot urgent client default is activated
1.3.6.1.4.1.20044.70.10.41Notificationpmo6006ClientTrapNotUrgentGoesOffcurrentNot urgent client default disappeared
1.3.6.1.4.1.20044.70.10.42Notificationpmo6006ClientTrapUrgentGoesOncurrentUrgent client default is activated
1.3.6.1.4.1.20044.70.10.43Notificationpmo6006ClientTrapUrgentGoesOffcurrentUrgent client default disappeared
1.3.6.1.4.1.20044.70.10.44Notificationpmo6006ClientTrapCritGoesOncurrentCritical client default is activated
1.3.6.1.4.1.20044.70.10.45Notificationpmo6006ClientTrapCritGoesOffcurrentCritical client default disappeared
1.3.6.1.4.1.20044.70.10.50Notificationpmo6006PowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.70.10.51Notificationpmo6006PowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared
1.3.6.1.4.1.20044.70.11Nodepmo6006Monitoring
1.3.6.1.4.1.20044.70.11.1Nodepmo6006MonOther
1.3.6.1.4.1.20044.70.11.1.3Nodepmo6006MonRmon
1.3.6.1.4.1.20044.70.11.1.3.359Scalarpmo6006MonCountersResetread-writecurrentRMON Counters Reset:This OID resets and restarts all the RMON counters
1.3.6.1.4.1.20044.70.11.1.3.360Scalarpmo6006MonCountersStopread-writecurrentRMON Counters stop:This OID stops all the RMON counters
1.3.6.1.4.1.20044.70.11.2Nodepmo6006MonClient
1.3.6.1.4.1.20044.70.11.2.4Nodepmo6006MonClientRmonCounter
1.3.6.1.4.1.20044.70.11.2.4.16Tablepmo6006MonupRmonBytesCounterClientInputTablenot-accessiblecurrentList of pmo6006MonupRmonBytesCounterClientInput Article
1.3.6.1.4.1.20044.70.11.2.4.16.1Rowpmo6006MonupRmonBytesCounterClientInputEntrynot-accessiblecurrentRow definition for the pmo6006MonupRmonBytesCounterClientInput table
1.3.6.1.4.1.20044.70.11.2.4.16.1.1Columnpmo6006MonupRmonBytesCounterClientInputIndexread-onlycurrentIndex definition for the pmo6006MonupRmonBytesCounterClientInput table
1.3.6.1.4.1.20044.70.11.2.4.16.1.2Columnpmo6006MonupRmonBytesCounterClientInputValuePortnread-onlycurrentClient Input Bytes :This counter is increased each time a data byte is received on the client port <Help> This counter gives the number of bytes received on th…
1.3.6.1.4.1.20044.70.11.2.4.16.1.3Columnpmo6006MonupRmonBytesCounterClientInputErrorPortnread-onlycurrentBytes Counter Error :This OID when set indicates the Bytes counter value is invalid on client port
1.3.6.1.4.1.20044.70.11.2.4.16.1.4Columnpmo6006MonupRmonBytesCounterClientInputOverloadPortnread-onlycurrentBytes Counter Overload :This OID when set indicates a Bytes counter overload on client port
1.3.6.1.4.1.20044.70.11.2.4.32Tablepmo6006MonupRmonCrcErrorsCounterClientInputTablenot-accessiblecurrentList of pmo6006MonupRmonCrcErrorsCounterClientInput Article
1.3.6.1.4.1.20044.70.11.2.4.32.1Rowpmo6006MonupRmonCrcErrorsCounterClientInputEntrynot-accessiblecurrentRow definition for the pmo6006MonupRmonCrcErrorsCounterClientInput table
1.3.6.1.4.1.20044.70.11.2.4.32.1.1Columnpmo6006MonupRmonCrcErrorsCounterClientInputIndexread-onlycurrentIndex definition for the pmo6006MonupRmonCrcErrorsCounterClientInput table
1.3.6.1.4.1.20044.70.11.2.4.32.1.2Columnpmo6006MonupRmonCrcErrorsCounterClientInputValuePortnread-onlycurrentClient Input CRC Errors :This counter is increased each time a B1/FCS error is detected on the client port <Help> This counter gives the number of B1/FCS Error…
1.3.6.1.4.1.20044.70.11.2.4.32.1.3Columnpmo6006MonupRmonCrcErrorsCounterClientInputErrorPortnread-onlycurrentB1/FCS Errors Counter Error :This OID when set indicates the B1/FCS Errors counter value is invalid on client port
1.3.6.1.4.1.20044.70.11.2.4.32.1.4Columnpmo6006MonupRmonCrcErrorsCounterClientInputOverloadPortnread-onlycurrentB1/FCS Errors Counter Overload :This OID when set indicates a B1/FCS Errors counter overload on client port
1.3.6.1.4.1.20044.70.11.2.4.48Tablepmo6006MonupRmonPacketsCounterClientInputTablenot-accessiblecurrentList of pmo6006MonupRmonPacketsCounterClientInput Article
1.3.6.1.4.1.20044.70.11.2.4.48.1Rowpmo6006MonupRmonPacketsCounterClientInputEntrynot-accessiblecurrentRow definition for the pmo6006MonupRmonPacketsCounterClientInput table
1.3.6.1.4.1.20044.70.11.2.4.48.1.1Columnpmo6006MonupRmonPacketsCounterClientInputIndexread-onlycurrentIndex definition for the pmo6006MonupRmonPacketsCounterClientInput table
1.3.6.1.4.1.20044.70.11.2.4.48.1.2Columnpmo6006MonupRmonPacketsCounterClientInputValuePortnread-onlycurrentClient Input Packets :This counter is increased each time a packet is received on the client port <Help> This counter gives the number of packets received on t…
1.3.6.1.4.1.20044.70.11.2.4.48.1.3Columnpmo6006MonupRmonPacketsCounterClientInputErrorPortnread-onlycurrentPackets Counter Error :This OID when set indicates the Packets counter value is invalid on client port
1.3.6.1.4.1.20044.70.11.2.4.48.1.4Columnpmo6006MonupRmonPacketsCounterClientInputOverloadPortnread-onlycurrentPackets Counter Overload :This OID when set indicates a Packets counter overload on client port
1.3.6.1.4.1.20044.70.11.2.4.64Tablepmo6006MonupRmonBroadcastCounterClientInputTablenot-accessiblecurrentList of pmo6006MonupRmonBroadcastCounterClientInput Article
1.3.6.1.4.1.20044.70.11.2.4.64.1Rowpmo6006MonupRmonBroadcastCounterClientInputEntrynot-accessiblecurrentRow definition for the pmo6006MonupRmonBroadcastCounterClientInput table
1.3.6.1.4.1.20044.70.11.2.4.64.1.1Columnpmo6006MonupRmonBroadcastCounterClientInputIndexread-onlycurrentIndex definition for the pmo6006MonupRmonBroadcastCounterClientInput table
1.3.6.1.4.1.20044.70.11.2.4.64.1.2Columnpmo6006MonupRmonBroadcastCounterClientInputValuePortnread-onlycurrentClient Input Broadcast Packets :This counter is increased each time a broadcast packet is received on the client port <Help> This counter gives the number of B…
1.3.6.1.4.1.20044.70.11.2.4.64.1.3Columnpmo6006MonupRmonBroadcastCounterClientInputErrorPortnread-onlycurrentBroadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on client port
1.3.6.1.4.1.20044.70.11.2.4.64.1.4Columnpmo6006MonupRmonBroadcastCounterClientInputOverloadPortnread-onlycurrentBroadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port
1.3.6.1.4.1.20044.70.11.2.4.80Tablepmo6006MonupRmonMulticastCounterClientInputTablenot-accessiblecurrentList of pmo6006MonupRmonMulticastCounterClientInput Article
1.3.6.1.4.1.20044.70.11.2.4.80.1Rowpmo6006MonupRmonMulticastCounterClientInputEntrynot-accessiblecurrentRow definition for the pmo6006MonupRmonMulticastCounterClientInput table
1.3.6.1.4.1.20044.70.11.2.4.80.1.1Columnpmo6006MonupRmonMulticastCounterClientInputIndexread-onlycurrentIndex definition for the pmo6006MonupRmonMulticastCounterClientInput table
1.3.6.1.4.1.20044.70.11.2.4.80.1.2Columnpmo6006MonupRmonMulticastCounterClientInputValuePortnread-onlycurrentClient Input Multicast Packets :This counter is increased each time a Multicast packet is received on the client port <Help> This counter gives the number of M…
1.3.6.1.4.1.20044.70.11.2.4.80.1.3Columnpmo6006MonupRmonMulticastCounterClientInputErrorPortnread-onlycurrentMulticast Counter Error :This OID when set indicates the Multicast counter value is invalid on client port
1.3.6.1.4.1.20044.70.11.2.4.80.1.4Columnpmo6006MonupRmonMulticastCounterClientInputOverloadPortnread-onlycurrentMulticast Counter Overload :This OID when set indicates a Multicast counter overload on client port
1.3.6.1.4.1.20044.70.11.2.4.96Tablepmo6006MonupRmonPauseFrameCounterClientInputTablenot-accessiblecurrentList of pmo6006MonupRmonPauseFrameCounterClientInput Article
1.3.6.1.4.1.20044.70.11.2.4.96.1Rowpmo6006MonupRmonPauseFrameCounterClientInputEntrynot-accessiblecurrentRow definition for the pmo6006MonupRmonPauseFrameCounterClientInput table
1.3.6.1.4.1.20044.70.11.2.4.96.1.1Columnpmo6006MonupRmonPauseFrameCounterClientInputIndexread-onlycurrentIndex definition for the pmo6006MonupRmonPauseFrameCounterClientInput table
1.3.6.1.4.1.20044.70.11.2.4.96.1.2Columnpmo6006MonupRmonPauseFrameCounterClientInputValuePortnread-onlycurrentClient Input Pause Frames :This counter is increased each time a Pause frame is received on the client port <Help> This counter gives the number of Pause frame…
1.3.6.1.4.1.20044.70.11.2.4.96.1.3Columnpmo6006MonupRmonPauseFrameCounterClientInputErrorPortnread-onlycurrentPause Counter Error :This OID when set indicates the Pause counter value is invalid on client port
1.3.6.1.4.1.20044.70.11.2.4.96.1.4Columnpmo6006MonupRmonPauseFrameCounterClientInputOverloadPortnread-onlycurrentPause Counter Overload :This OID when set indicates a Pause counter overload on client port
1.3.6.1.4.1.20044.70.11.2.4.224Tablepmo6006MondwRmonCrcErrorsCounterClientInputTablenot-accessiblecurrentList of pmo6006MondwRmonCrcErrorsCounterClientInput Article
1.3.6.1.4.1.20044.70.11.2.4.224.1Rowpmo6006MondwRmonCrcErrorsCounterClientInputEntrynot-accessiblecurrentRow definition for the pmo6006MondwRmonCrcErrorsCounterClientInput table
1.3.6.1.4.1.20044.70.11.2.4.224.1.1Columnpmo6006MondwRmonCrcErrorsCounterClientInputIndexread-onlycurrentIndex definition for the pmo6006MondwRmonCrcErrorsCounterClientInput table
1.3.6.1.4.1.20044.70.11.2.4.224.1.2Columnpmo6006MondwRmonCrcErrorsCounterClientInputValuePortnread-onlycurrentClient Output B1/CRC Errors :This counter is increased each time a B1/FCS error is detected on the output client port <Help> This counter gives the number of B…
1.3.6.1.4.1.20044.70.11.2.4.224.1.3Columnpmo6006MondwRmonCrcErrorsCounterClientInputErrorPortnread-onlycurrentOutput B1/FCS Errors Counter Error :This OID when set indicates the output B1/FCS Errors counter value is invalid on client port
1.3.6.1.4.1.20044.70.11.2.4.224.1.4Columnpmo6006MondwRmonCrcErrorsCounterClientInputOverloadPortnread-onlycurrentOutput B1/FCS Errors Counter Overload :This OID when set indicates an output B1/FCS Errors counter overload on client port
1.3.6.1.4.1.20044.70.11.2.4.240Tablepmo6006MondwRmonPacketsCounterClientInputTablenot-accessiblecurrentList of pmo6006MondwRmonPacketsCounterClientInput Article
1.3.6.1.4.1.20044.70.11.2.4.240.1Rowpmo6006MondwRmonPacketsCounterClientInputEntrynot-accessiblecurrentRow definition for the pmo6006MondwRmonPacketsCounterClientInput table
1.3.6.1.4.1.20044.70.11.2.4.240.1.1Columnpmo6006MondwRmonPacketsCounterClientInputIndexread-onlycurrentIndex definition for the pmo6006MondwRmonPacketsCounterClientInput table
1.3.6.1.4.1.20044.70.11.2.4.240.1.2Columnpmo6006MondwRmonPacketsCounterClientInputValuePortnread-onlycurrentClient Output Packets :This counter is increased each time a packet is transmitted on the client port. <Help> This counter gives the number of packets detected…
1.3.6.1.4.1.20044.70.11.2.4.240.1.3Columnpmo6006MondwRmonPacketsCounterClientInputErrorPortnread-onlycurrentOutput Packets Counter Error :This OID when set indicates the output Packets counter value is invalid on client port
1.3.6.1.4.1.20044.70.11.2.4.240.1.4Columnpmo6006MondwRmonPacketsCounterClientInputOverloadPortnread-onlycurrentOutput Packets Counter Overload :This OID when set indicates an output Packets counter overload on client port
Type Definitions
NameSyntaxStatusDescription
Pmo6006DccModeINTEGER { dccNo(0), dccLine1(1), dccLine2(2) }currentMode for DCC
Pmo6006LineChannelINTEGERcurrentChannel selection on transceiver Line ports
Pmo6006Odu2SapiModeINTEGER { off(0), sapi(1) dapi(2) sapidapi(3), }currentMode for SAPI-DAPI
Pmo6006Otu2SapiModeINTEGER { off(0), sapi(1) dapi(2) sapidapi(3), }currentMode for SAPI-DAPI
Pmo6006OtxGridINTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50) }currentDifferent grids on client and line ports