EKINOPS-Pmo6006-MIB
517 objects
Creation.
Imported Objects
| EKINOPS-MIB | EkiApiState EkiMeasureType EkiMode ekinops EkiOnOff EkiProtocol EkiState EkiSynchroMode |
| SNMPv2-SMI | Counter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20044.70 | IdentitymodulePmo6006 | Creation. | ||
| 1.3.6.1.4.1.20044.70.2 | Nodepmo6006alarms | |||
| 1.3.6.1.4.1.20044.70.2.1 | Nodepmo6006AlmOther | |||
| 1.3.6.1.4.1.20044.70.2.1.1 | Nodepmo6006AlmOtherNurg | |||
| 1.3.6.1.4.1.20044.70.2.1.1.2 | Nodepmo6006AlmsynthAlm2 | |||
| 1.3.6.1.4.1.20044.70.2.1.1.2.1 | Scalarpmo6006AlmConfTableSave | read-only | current | PM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> infor… |
| 1.3.6.1.4.1.20044.70.2.1.1.2.2 | Scalarpmo6006AlmInvUpload | read-only | current | Inventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> informationalStatus(1000) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.70.2.1.1.2.3 | Scalarpmo6006AlmConfTableLoad | read-only | current | PM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> informationalStat… |
| 1.3.6.1.4.1.20044.70.2.1.1.2.4 | Scalarpmo6006AlmCorrelatOff | read-only | current | Not Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> informationalStatus(1000) <Alarmtype… |
| 1.3.6.1.4.1.20044.70.2.1.2 | Nodepmo6006AlmOtherUrg | |||
| 1.3.6.1.4.1.20044.70.2.1.3 | Nodepmo6006AlmOtherCrit | |||
| 1.3.6.1.4.1.20044.70.2.1.3.0 | Nodepmo6006AlmsynthAlm0 | |||
| 1.3.6.1.4.1.20044.70.2.1.3.0.9 | Scalarpmo6006AlmModGlobFail | read-only | current | Module Failure :This OID is set on detection of a failure originating from the RM <Help> This alarm is set on detection of a failure originating from the equip… |
| 1.3.6.1.4.1.20044.70.2.1.3.0.15 | Scalarpmo6006AlmDefFuseA | read-only | current | Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.70.2.1.3.0.16 | Scalarpmo6006AlmDefFuseB | read-only | current | Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.70.2.2 | Nodepmo6006AlmClient | |||
| 1.3.6.1.4.1.20044.70.2.2.1 | Nodepmo6006AlmClientNurg | |||
| 1.3.6.1.4.1.20044.70.2.2.1.232 | Tablepmo6006AlmclientSfpWarnDdmTable | not-accessible | current | List of pmo6006AlmclientSfpWarnDdm Article |
| 1.3.6.1.4.1.20044.70.2.2.1.232.1 | Rowpmo6006AlmclientSfpWarnDdmEntry | not-accessible | current | Row definition for the pmo6006AlmclientSfpWarnDdm table |
| 1.3.6.1.4.1.20044.70.2.2.1.232.1.1 | Columnpmo6006AlmclientSfpWarnDdmIndex | read-only | current | Index definition for the pmo6006AlmclientSfpWarnDdm table |
| 1.3.6.1.4.1.20044.70.2.2.1.232.1.2 | Columnpmo6006AlmClientTxPwLowWngPortn | read-only | current | Client Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning … |
| 1.3.6.1.4.1.20044.70.2.2.1.232.1.3 | Columnpmo6006AlmClientTxPwrHighWngPortn | read-only | current | Client Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warnin… |
| 1.3.6.1.4.1.20044.70.2.2.1.232.1.4 | Columnpmo6006AlmClientTxBiasLowWngPortn | read-only | current | Client Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warnin… |
| 1.3.6.1.4.1.20044.70.2.2.1.232.1.5 | Columnpmo6006AlmClientTxBiasHighWngPortn | read-only | current | Client Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warn… |
| 1.3.6.1.4.1.20044.70.2.2.1.232.1.6 | Columnpmo6006AlmClientVccLowWngPortn | read-only | current | Client Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Warn… |
| 1.3.6.1.4.1.20044.70.2.2.1.232.1.7 | Columnpmo6006AlmClientVccHighWngPortn | read-only | current | Client Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Wa… |
| 1.3.6.1.4.1.20044.70.2.2.1.232.1.8 | Columnpmo6006AlmClientTempLowWngPortn | read-only | current | Client Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indic… |
| 1.3.6.1.4.1.20044.70.2.2.1.232.1.9 | Columnpmo6006AlmClientTempHighWngPortn | read-only | current | Client Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning ind… |
| 1.3.6.1.4.1.20044.70.2.2.1.232.1.16 | Columnpmo6006AlmClientRxPwrLowWngPortn | read-only | current | Client Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning i… |
| 1.3.6.1.4.1.20044.70.2.2.1.232.1.17 | Columnpmo6006AlmClientRxPwrHighWngPortn | read-only | current | Client Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning… |
| 1.3.6.1.4.1.20044.70.2.2.2 | Nodepmo6006AlmClientUrg | |||
| 1.3.6.1.4.1.20044.70.2.2.2.88 | Tablepmo6006AlmclientHostLaneFaultTable | not-accessible | current | List of pmo6006AlmclientHostLaneFault Article |
| 1.3.6.1.4.1.20044.70.2.2.2.88.1 | Rowpmo6006AlmclientHostLaneFaultEntry | not-accessible | current | Row definition for the pmo6006AlmclientHostLaneFault table |
| 1.3.6.1.4.1.20044.70.2.2.2.88.1.1 | Columnpmo6006AlmclientHostLaneFaultIndex | read-only | current | Index definition for the pmo6006AlmclientHostLaneFault table |
| 1.3.6.1.4.1.20044.70.2.2.2.88.1.2 | Columnpmo6006AlmClientLossOfSyncPortn | read-only | current | Client Frame Alignment Loss :This OID indicates the module is not aligned with the incoming Client signal <Help> Alarm indicating the module is not aligned wit… |
| 1.3.6.1.4.1.20044.70.2.2.2.88.1.3 | Columnpmo6006AlmClientInputLossOfSigPortn | read-only | current | Client Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Client Trscv <Help> Alarm indicating a Loss of Signal is detected on the Cl… |
| 1.3.6.1.4.1.20044.70.2.2.2.88.1.4 | Columnpmo6006AlmClientOdu2eDplmPortn | read-only | current | ODU2e DPLM :This OID indicates a Payload Mismatch is detected on the Client port<Help> Alarm indicating a Payload Mismatch <Condtype> CLIENT_ODU2E_DPLM <Probca… |
| 1.3.6.1.4.1.20044.70.2.2.2.88.1.6 | Columnpmo6006AlmClientOdu2eDdegPortn | read-only | current | ODU2e DDEG :This OID indicates that a Signal Degrade has been detected on client port<Help> Alarm indicating a Signal Degrade upon threshold and confirmation p… |
| 1.3.6.1.4.1.20044.70.2.2.2.88.1.7 | Columnpmo6006AlmClientCsfDetectedPortn | read-only | current | ETH DCSF :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client Signal Fail has be… |
| 1.3.6.1.4.1.20044.70.2.2.2.88.1.8 | Columnpmo6006AlmClientOdu2eIaisPortn | read-only | current | ODU2e IAIS :This OID indicates that an Alarm Indication Signal has been inserted on client port <Help> This alarm indicates if an Alarm Indication Signal has b… |
| 1.3.6.1.4.1.20044.70.2.2.2.88.1.9 | Columnpmo6006AlmClientOdu2eDtimPortn | read-only | current | ODU2e DTIM :This OID indicates that a Trace Identifier Mismatch has been detected on client port<Help> This alarm indicates if an Trace Identifier Mismatch has… |
| 1.3.6.1.4.1.20044.70.2.2.2.88.1.10 | Columnpmo6006AlmClientOdu2eDaisPortn | read-only | current | ODU2e DAIS :This OID indicates that a Alarm Indication SIgnal has been detected on client port<Help> This alarm indicates if an Alarm Indication Signal has bee… |
| 1.3.6.1.4.1.20044.70.2.2.2.88.1.11 | Columnpmo6006AlmClientLaneTxFifoErrorPortn | read-only | current | Client Tx FIFO Error :This OID indicates a Tx FIFO Error on the Client Trscv <Help> Alarm indicating a Tx FIFO Error on the Client Trscv <Condtype> CLIENT_LANE… |
| 1.3.6.1.4.1.20044.70.2.2.2.88.1.12 | Columnpmo6006AlmClientOdu2eIociPortn | read-only | current | ODU2e IOCI :This OID indicates that an Open Connection has been inserted on client port <Help> This alarm indicates if an Open Connection Indication has been i… |
| 1.3.6.1.4.1.20044.70.2.2.2.88.1.13 | Columnpmo6006AlmClientOdu2eDociPortn | read-only | current | ODU2e DOCI :This OID indicates that a Open Connection has been detected on client port <Help> This alarm indicates if an Open Connection Indication has been de… |
| 1.3.6.1.4.1.20044.70.2.2.2.88.1.14 | Columnpmo6006AlmClientOdu2eIbdiPortn | read-only | current | ODU2e IBDI :This OID indicates that a Backward Defect Indication has been inserted on client port <Help> This alarm indicates if a Backward Defect Indication h… |
| 1.3.6.1.4.1.20044.70.2.2.2.88.1.15 | Columnpmo6006AlmClientOdu2eDbdiPortn | read-only | current | ODU2e DBDI :This OID indicates that a Backward Defect Indication has been detected on client port<Help> This alarm indicates if a Backward Defect Indication ha… |
| 1.3.6.1.4.1.20044.70.2.2.2.88.1.16 | Columnpmo6006AlmClientOdu2eIlckPortn | read-only | current | ODU2e ILCK :This OID indicates that a Locked Indication has been inserted on client port <Help> This alarm indicates if a Locked Indication has been inserted o… |
| 1.3.6.1.4.1.20044.70.2.2.2.88.1.17 | Columnpmo6006AlmClientOdu2eDlckPortn | read-only | current | ODU2e DLCK :This OID indicates that a Locked Indication has been detected on client port <Help> This alarm indicates if a Locked Indication has been detected o… |
| 1.3.6.1.4.1.20044.70.2.2.2.216 | Tablepmo6006AlmclientSfpAlmDdmTable | not-accessible | current | List of pmo6006AlmclientSfpAlmDdm Article |
| 1.3.6.1.4.1.20044.70.2.2.2.216.1 | Rowpmo6006AlmclientSfpAlmDdmEntry | not-accessible | current | Row definition for the pmo6006AlmclientSfpAlmDdm table |
| 1.3.6.1.4.1.20044.70.2.2.2.216.1.1 | Columnpmo6006AlmclientSfpAlmDdmIndex | read-only | current | Index definition for the pmo6006AlmclientSfpAlmDdm table |
| 1.3.6.1.4.1.20044.70.2.2.2.216.1.2 | Columnpmo6006AlmClientTxPwrLowAlaPortn | read-only | current | Client Trscv Tx Power Low :This OID indicates that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in… |
| 1.3.6.1.4.1.20044.70.2.2.2.216.1.3 | Columnpmo6006AlmClientTxPwrHighAlaPortn | read-only | current | Client Trscv Tx Power High :This OID indicates that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm … |
| 1.3.6.1.4.1.20044.70.2.2.2.216.1.4 | Columnpmo6006AlmClientTxBiasLowAlaPortn | read-only | current | Client Trscv Bias Low :This OID indicates that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm … |
| 1.3.6.1.4.1.20044.70.2.2.2.216.1.5 | Columnpmo6006AlmClientTxBiasHighAlaPortn | read-only | current | Client Trscv Bias High :This OID indicates that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM <Help> Alar… |
| 1.3.6.1.4.1.20044.70.2.2.2.216.1.6 | Columnpmo6006AlmClientVccLowAlaPortn | read-only | current | Client Trscv Power Supply Low :This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM <Help> Alar… |
| 1.3.6.1.4.1.20044.70.2.2.2.216.1.7 | Columnpmo6006AlmClientVccHighAlaPortn | read-only | current | Client Trscv Power Supply High :This OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM <Help> Al… |
| 1.3.6.1.4.1.20044.70.2.2.2.216.1.8 | Columnpmo6006AlmClientTempLowAlaPortn | read-only | current | Client Trscv Temp Low :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicat… |
| 1.3.6.1.4.1.20044.70.2.2.2.216.1.9 | Columnpmo6006AlmClientTempHighAlaPortn | read-only | current | Client Trscv Temp High :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indic… |
| 1.3.6.1.4.1.20044.70.2.2.2.216.1.16 | Columnpmo6006AlmClientRxPwrLowAlaPortn | read-only | current | Client Trscv Rx Power Low :This OID indicates that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm ind… |
| 1.3.6.1.4.1.20044.70.2.2.2.216.1.17 | Columnpmo6006AlmClientRxPwrHighAlaPortn | read-only | current | Client Trscv Rx Power High :This OID indicates that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm i… |
| 1.3.6.1.4.1.20044.70.2.2.3 | Nodepmo6006AlmClientCrit | |||
| 1.3.6.1.4.1.20044.70.2.2.3.8 | Tablepmo6006AlmsynthAlmPortTable | not-accessible | current | List of pmo6006AlmsynthAlmPort Article |
| 1.3.6.1.4.1.20044.70.2.2.3.8.1 | Rowpmo6006AlmsynthAlmPortEntry | not-accessible | current | Row definition for the pmo6006AlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.70.2.2.3.8.1.1 | Columnpmo6006AlmsynthAlmPortIndex | read-only | current | Index definition for the pmo6006AlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.70.2.2.3.8.1.2 | Columnpmo6006AlmSfpAbsentPortn | read-only | current | Client SFP Absent :This OID indicates that the Transceiver is not present in the client port. <Help> This alarm indicates if the client transceiver is not plug… |
| 1.3.6.1.4.1.20044.70.2.2.3.8.1.3 | Columnpmo6006AlmDdmAbsentPortn | read-only | current | DDM Supported On Client Trscv :This OID indicates that the Client transceiver supports the Digital Diagnostic Monitoring function <Help> This status indicates … |
| 1.3.6.1.4.1.20044.70.2.2.3.8.1.5 | Columnpmo6006AlmHwFailAccPortn | read-only | current | Client HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Help> This alarm indicates a failure on client port, most pro… |
| 1.3.6.1.4.1.20044.70.2.2.3.8.1.6 | Columnpmo6006AlmDwLsdPortn | read-only | current | Client SFP Laser Shutdown :This OID indicates the Client transceiver laser is shutdown <Help> This status indicates if the client transceiver laser is shutdown… |
| 1.3.6.1.4.1.20044.70.2.2.3.8.1.7 | Columnpmo6006AlmClientLocalOosPortn | read-only | current | Local Client Port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local c… |
| 1.3.6.1.4.1.20044.70.2.2.3.8.1.8 | Columnpmo6006AlmClientRemoteOosPortn | read-only | current | Remote Client Port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the remot… |
| 1.3.6.1.4.1.20044.70.2.2.3.8.1.9 | Columnpmo6006AlmDwCaisPortn | read-only | current | Client AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indicates if a Client Alarm Indication Signal is… |
| 1.3.6.1.4.1.20044.70.2.2.3.8.1.10 | Columnpmo6006AlmSfpDdmWarningPortn | read-only | current | Warning On Client Trscv DDM :This OID indicates a warning is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Warning has be… |
| 1.3.6.1.4.1.20044.70.2.2.3.8.1.11 | Columnpmo6006AlmSfpDdmAlmPortn | read-only | current | Alarm On Client Trscv DDM :This OID indicates an alarm is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Alarm has been de… |
| 1.3.6.1.4.1.20044.70.2.2.3.8.1.13 | Columnpmo6006AlmFailAccPortn | read-only | current | Client Access Fail :This OID indicates a failure on the Client port <Help> This alarm indicates a failure on the Client port <Condtype> FAIL_ACC_1 <Probcause> … |
| 1.3.6.1.4.1.20044.70.2.2.3.8.1.17 | Columnpmo6006AlmUpCsfPortn | read-only | current | Client Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu… |
| 1.3.6.1.4.1.20044.70.2.3 | Nodepmo6006AlmLine | |||
| 1.3.6.1.4.1.20044.70.2.3.1 | Nodepmo6006AlmLineNurg | |||
| 1.3.6.1.4.1.20044.70.2.3.2 | Nodepmo6006AlmLineUrg | |||
| 1.3.6.1.4.1.20044.70.2.3.2.104 | Tablepmo6006AlmlineNetworkLaneAlarmWarning1Table | not-accessible | current | List of pmo6006AlmlineNetworkLaneAlarmWarning1 Article |
| 1.3.6.1.4.1.20044.70.2.3.2.104.1 | Rowpmo6006AlmlineNetworkLaneAlarmWarning1Entry | not-accessible | current | Row definition for the pmo6006AlmlineNetworkLaneAlarmWarning1 table |
| 1.3.6.1.4.1.20044.70.2.3.2.104.1.1 | Columnpmo6006AlmlineNetworkLaneAlarmWarning1Index | read-only | current | Index definition for the pmo6006AlmlineNetworkLaneAlarmWarning1 table |
| 1.3.6.1.4.1.20044.70.2.3.2.104.1.2 | Columnpmo6006AlmLineTxPwrLowAlaPortn | read-only | current | Line Trscv Tx Power Low :This OID indicates that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indi… |
| 1.3.6.1.4.1.20044.70.2.3.2.104.1.3 | Columnpmo6006AlmLineTxPwrHighAlaPortn | read-only | current | Line Trscv Tx Power High :This OID indicates that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm in… |
| 1.3.6.1.4.1.20044.70.2.3.2.104.1.4 | Columnpmo6006AlmLineTxBiasLowAlaPortn | read-only | current | Line Trscv Bias Low :This OID indicates that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in… |
| 1.3.6.1.4.1.20044.70.2.3.2.104.1.5 | Columnpmo6006AlmLineTxBiasHighAlaPortn | read-only | current | Line Trscv Bias High :This OID indicates that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm … |
| 1.3.6.1.4.1.20044.70.2.3.2.104.1.6 | Columnpmo6006AlmLineVccLowAlaPortn | read-only | current | Line Trscv Power Supply Low :This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm … |
| 1.3.6.1.4.1.20044.70.2.3.2.104.1.7 | Columnpmo6006AlmLineVccHighAlaPortn | read-only | current | Line Trscv Power Supply High :This OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM <Help> Alar… |
| 1.3.6.1.4.1.20044.70.2.3.2.104.1.8 | Columnpmo6006AlmLineTempLowAlaPortn | read-only | current | Line Trscv Temp Low :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicatin… |
| 1.3.6.1.4.1.20044.70.2.3.2.104.1.9 | Columnpmo6006AlmLineTempHighAlaPortn | read-only | current | Line Trscv Temp High :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indicat… |
| 1.3.6.1.4.1.20044.70.2.3.2.104.1.16 | Columnpmo6006AlmLineRxPwrLowAlaPortn | read-only | current | Line Trscv Rx Power Low :This OID indicates that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indic… |
| 1.3.6.1.4.1.20044.70.2.3.2.104.1.17 | Columnpmo6006AlmLineRxPwrHighAlaPortn | read-only | current | Line Trscv Rx Power High :This OID indicates that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm ind… |
| 1.3.6.1.4.1.20044.70.2.3.2.120 | Tablepmo6006AlmlineNetworkLaneAlarmWarning2Table | not-accessible | current | List of pmo6006AlmlineNetworkLaneAlarmWarning2 Article |
| 1.3.6.1.4.1.20044.70.2.3.2.120.1 | Rowpmo6006AlmlineNetworkLaneAlarmWarning2Entry | not-accessible | current | Row definition for the pmo6006AlmlineNetworkLaneAlarmWarning2 table |
| 1.3.6.1.4.1.20044.70.2.3.2.120.1.1 | Columnpmo6006AlmlineNetworkLaneAlarmWarning2Index | read-only | current | Index definition for the pmo6006AlmlineNetworkLaneAlarmWarning2 table |
| 1.3.6.1.4.1.20044.70.2.3.2.120.1.2 | Columnpmo6006AlmLineTxPwLowWngPortn | read-only | current | Line Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning in… |
| 1.3.6.1.4.1.20044.70.2.3.2.120.1.3 | Columnpmo6006AlmLineTxPwrHighWngPortn | read-only | current | Line Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warning … |
| 1.3.6.1.4.1.20044.70.2.3.2.120.1.4 | Columnpmo6006AlmLineTxBiasLowWngPortn | read-only | current | Line Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warning … |
| 1.3.6.1.4.1.20044.70.2.3.2.120.1.5 | Columnpmo6006AlmLineTxBiasHighWngPortn | read-only | current | Line Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warnin… |
| 1.3.6.1.4.1.20044.70.2.3.2.120.1.6 | Columnpmo6006AlmLineVccLowWngPortn | read-only | current | Line Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Warnin… |
| 1.3.6.1.4.1.20044.70.2.3.2.120.1.7 | Columnpmo6006AlmLineVccHighWngPortn | read-only | current | Line Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Warn… |
| 1.3.6.1.4.1.20044.70.2.3.2.120.1.8 | Columnpmo6006AlmLineTempLowWngPortn | read-only | current | Line Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indicat… |
| 1.3.6.1.4.1.20044.70.2.3.2.120.1.9 | Columnpmo6006AlmLineTempHighWngPortn | read-only | current | Line Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning indic… |
| 1.3.6.1.4.1.20044.70.2.3.2.120.1.16 | Columnpmo6006AlmLineRxPwrLowWngPortn | read-only | current | Line Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning ind… |
| 1.3.6.1.4.1.20044.70.2.3.2.120.1.17 | Columnpmo6006AlmLineRxPwrHighWngPortn | read-only | current | Line Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning i… |
| 1.3.6.1.4.1.20044.70.2.3.2.152 | Tablepmo6006AlmlineHostLaneFaultTable | not-accessible | current | List of pmo6006AlmlineHostLaneFault Article |
| 1.3.6.1.4.1.20044.70.2.3.2.152.1 | Rowpmo6006AlmlineHostLaneFaultEntry | not-accessible | current | Row definition for the pmo6006AlmlineHostLaneFault table |
| 1.3.6.1.4.1.20044.70.2.3.2.152.1.1 | Columnpmo6006AlmlineHostLaneFaultIndex | read-only | current | Index definition for the pmo6006AlmlineHostLaneFault table |
| 1.3.6.1.4.1.20044.70.2.3.2.152.1.2 | Columnpmo6006AlmLineInputLossOfSignalPortn | read-only | current | OPS2e DLOS-P :This OID indicates a Loss of Signal is detected on the Line Trscv<Help> This alarm indicates if an Optical Path Break has been detected on the li… |
| 1.3.6.1.4.1.20044.70.2.3.2.152.1.3 | Columnpmo6006AlmLineLossOfFramePortn | read-only | current | OTU2e - DLOF :This OID indicates the module is not aligned with the incoming Line signal<Help> This alarm indicates if a Loss Of Frame has been detected on the… |
| 1.3.6.1.4.1.20044.70.2.3.2.152.1.4 | Columnpmo6006AlmLineSmBdiInsertedPortn | read-only | current | OTU2e IBDI :This OID indicates a SM Backward Defect Indication is inserted on the outgoing Line signal<Help> This alarm indicates if a Backward Defect Indicati… |
| 1.3.6.1.4.1.20044.70.2.3.2.152.1.5 | Columnpmo6006AlmLineSmBdiDetectedPortn | read-only | current | OTU2e DBDI :This OID indicates a SM Backward Defect Indication is detected on the incoming Line signal<Help> This alarm indicates if a Backward Defect Indicati… |
| 1.3.6.1.4.1.20044.70.2.3.2.152.1.8 | Columnpmo6006AlmOtu2eDdegPortn | read-only | current | OTU2e DDEG :This OID indicates that a Signal Degrade has been detected on line port <Help> This alarm indicates if a Signal Degrade has been detected upon thre… |
| 1.3.6.1.4.1.20044.70.2.3.2.152.1.9 | Columnpmo6006AlmClientOtu2eDtimPortn | read-only | current | OTU2e DTIM :This OID indicates that a Trace Identifier Mismatch has been detected on line port <Help> This alarm indicates if a Trace Idenifier Mismatch has be… |
| 1.3.6.1.4.1.20044.70.2.3.2.152.1.12 | Columnpmo6006AlmLineOchr2eDlosPPortn | read-only | current | Ochr2e - DLOS-P :This OID indicates that a Transmitter failure has been detected on line port <Help> This alarm indicates if a Transmitter Failure has been det… |
| 1.3.6.1.4.1.20044.70.2.3.2.152.1.16 | Columnpmo6006AlmLineOtu2eDssfPortn | read-only | current | OTU2e DSSF :This OID indicates that a Server Signal failure has been detected on line port <Help> This alarm indicates if a Server Signal Failure has been dete… |
| 1.3.6.1.4.1.20044.70.2.3.2.152.1.17 | Columnpmo6006AlmLineOtu2eDlomPortn | read-only | current | OTU2e DLOM :This OID indicates that a Loss Of Multiframe has been detected on line port <Help> This alarm indicates if a Loss Of Multiframe has been detected o… |
| 1.3.6.1.4.1.20044.70.2.3.3 | Nodepmo6006AlmLineCrit | |||
| 1.3.6.1.4.1.20044.70.2.3.3.24 | Tablepmo6006AlmsynthAlmLineTable | not-accessible | current | List of pmo6006AlmsynthAlmLine Article |
| 1.3.6.1.4.1.20044.70.2.3.3.24.1 | Rowpmo6006AlmsynthAlmLineEntry | not-accessible | current | Row definition for the pmo6006AlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.70.2.3.3.24.1.1 | Columnpmo6006AlmsynthAlmLineIndex | read-only | current | Index definition for the pmo6006AlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.70.2.3.3.24.1.2 | Columnpmo6006AlmLineSfpAbsentPortn | read-only | current | Line Optical Module Absent :This OID indicates that the line optical interface is not present. <Help> This alarm indicates if the line transceiver is not plugg… |
| 1.3.6.1.4.1.20044.70.2.3.3.24.1.3 | Columnpmo6006AlmLineDdmAbsentPortn | read-only | current | Line Optical Module Ready :This OID indicates that the optical interface is not operational. <Help> This status indicates if the line transceiver has been corr… |
| 1.3.6.1.4.1.20044.70.2.3.3.24.1.5 | Columnpmo6006AlmLineHwFailPortn | read-only | current | Line Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Help> This alarm indicates a failure on line port, most pr… |
| 1.3.6.1.4.1.20044.70.2.3.3.24.1.6 | Columnpmo6006AlmLineTxOffPortn | read-only | current | Line Optical Module Laser Shutdown :This OID indicates the Line transceiver laser is shutdown <Help> This status indicates if the Line transceiver laser is shu… |
| 1.3.6.1.4.1.20044.70.2.3.3.24.1.7 | Columnpmo6006AlmLineLocalOosPortn | read-only | current | Line Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service… |
| 1.3.6.1.4.1.20044.70.2.3.3.24.1.9 | Columnpmo6006AlmUpRdiInsPortn | read-only | current | MS-RDI/L-RDI Inserted On Line :This OID indicates an upstream MS-RDI/L-RDI has been inserted in the outgoing 10 Gb/s SDH/SONET signal. <Help> This status indic… |
| 1.3.6.1.4.1.20044.70.2.3.3.24.1.10 | Columnpmo6006AlmLineDdmWarningPortn | read-only | current | Warning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Warning has… |
| 1.3.6.1.4.1.20044.70.2.3.3.24.1.11 | Columnpmo6006AlmLineDdmAlmPortn | read-only | current | Alarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Alarm has been… |
| 1.3.6.1.4.1.20044.70.2.3.3.24.1.13 | Columnpmo6006AlmLineFailPortn | read-only | current | Line Port Failure :This OID indicates a failure on the line port <Help> This alarm indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipm… |
| 1.3.6.1.4.1.20044.70.3 | Nodepmo6006measures | |||
| 1.3.6.1.4.1.20044.70.3.1 | Nodepmo6006MesrOther | |||
| 1.3.6.1.4.1.20044.70.3.2 | Nodepmo6006MesrClient | |||
| 1.3.6.1.4.1.20044.70.3.2.16 | Tablepmo6006MesrclientTempTable | not-accessible | current | List of pmo6006MesrclientTemp Article |
| 1.3.6.1.4.1.20044.70.3.2.16.1 | Rowpmo6006MesrclientTempEntry | not-accessible | current | Row definition for the pmo6006MesrclientTemp table |
| 1.3.6.1.4.1.20044.70.3.2.16.1.1 | Columnpmo6006MesrclientTempIndex | read-only | current | Index definition for the pmo6006MesrclientTemp table |
| 1.3.6.1.4.1.20044.70.3.2.16.1.2 | Columnpmo6006MesrclientTempPortn | read-only | current | Client SFP Temperature :This OID gives the Laser temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = … |
| 1.3.6.1.4.1.20044.70.3.2.32 | Tablepmo6006MesrclientTxBiasTable | not-accessible | current | List of pmo6006MesrclientTxBias Article |
| 1.3.6.1.4.1.20044.70.3.2.32.1 | Rowpmo6006MesrclientTxBiasEntry | not-accessible | current | Row definition for the pmo6006MesrclientTxBias table |
| 1.3.6.1.4.1.20044.70.3.2.32.1.1 | Columnpmo6006MesrclientTxBiasIndex | read-only | current | Index definition for the pmo6006MesrclientTxBias table |
| 1.3.6.1.4.1.20044.70.3.2.32.1.2 | Columnpmo6006MesrclientTxBiasPortn | read-only | current | Client SFP Laser Bias :This OID gives the Laser bias value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit =… |
| 1.3.6.1.4.1.20044.70.3.2.48 | Tablepmo6006MesrclientTxPwrTable | not-accessible | current | List of pmo6006MesrclientTxPwr Article |
| 1.3.6.1.4.1.20044.70.3.2.48.1 | Rowpmo6006MesrclientTxPwrEntry | not-accessible | current | Row definition for the pmo6006MesrclientTxPwr table |
| 1.3.6.1.4.1.20044.70.3.2.48.1.1 | Columnpmo6006MesrclientTxPwrIndex | read-only | current | Index definition for the pmo6006MesrclientTxPwr table |
| 1.3.6.1.4.1.20044.70.3.2.48.1.2 | Columnpmo6006MesrclientTxPwrPortn | read-only | current | Client SFP Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-4… |
| 1.3.6.1.4.1.20044.70.3.2.64 | Tablepmo6006MesrclientRxPwrTable | not-accessible | current | List of pmo6006MesrclientRxPwr Article |
| 1.3.6.1.4.1.20044.70.3.2.64.1 | Rowpmo6006MesrclientRxPwrEntry | not-accessible | current | Row definition for the pmo6006MesrclientRxPwr table |
| 1.3.6.1.4.1.20044.70.3.2.64.1.1 | Columnpmo6006MesrclientRxPwrIndex | read-only | current | Index definition for the pmo6006MesrclientRxPwr table |
| 1.3.6.1.4.1.20044.70.3.2.64.1.2 | Columnpmo6006MesrclientRxPwrPortn | read-only | current | Client SFP Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) … |
| 1.3.6.1.4.1.20044.70.3.3 | Nodepmo6006MesrLine | |||
| 1.3.6.1.4.1.20044.70.3.3.80 | Tablepmo6006MesrlineTxPwrTable | not-accessible | current | List of pmo6006MesrlineTxPwr Article |
| 1.3.6.1.4.1.20044.70.3.3.80.1 | Rowpmo6006MesrlineTxPwrEntry | not-accessible | current | Row definition for the pmo6006MesrlineTxPwr table |
| 1.3.6.1.4.1.20044.70.3.3.80.1.1 | Columnpmo6006MesrlineTxPwrIndex | read-only | current | Index definition for the pmo6006MesrlineTxPwr table |
| 1.3.6.1.4.1.20044.70.3.3.80.1.2 | Columnpmo6006MesrlineTxPwrPortn | read-only | current | Line Optical Module Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power … |
| 1.3.6.1.4.1.20044.70.3.3.96 | Tablepmo6006MesrlineTempTable | not-accessible | current | List of pmo6006MesrlineTemp Article |
| 1.3.6.1.4.1.20044.70.3.3.96.1 | Rowpmo6006MesrlineTempEntry | not-accessible | current | Row definition for the pmo6006MesrlineTemp table |
| 1.3.6.1.4.1.20044.70.3.3.96.1.1 | Columnpmo6006MesrlineTempIndex | read-only | current | Index definition for the pmo6006MesrlineTemp table |
| 1.3.6.1.4.1.20044.70.3.3.96.1.2 | Columnpmo6006MesrlineTempPortn | read-only | current | Line Optical Module Temperature :This OID gives the Tx Laser Temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temp… |
| 1.3.6.1.4.1.20044.70.3.3.112 | Tablepmo6006MesrlineTxBiasTable | not-accessible | current | List of pmo6006MesrlineTxBias Article |
| 1.3.6.1.4.1.20044.70.3.3.112.1 | Rowpmo6006MesrlineTxBiasEntry | not-accessible | current | Row definition for the pmo6006MesrlineTxBias table |
| 1.3.6.1.4.1.20044.70.3.3.112.1.1 | Columnpmo6006MesrlineTxBiasIndex | read-only | current | Index definition for the pmo6006MesrlineTxBias table |
| 1.3.6.1.4.1.20044.70.3.3.112.1.2 | Columnpmo6006MesrlineTxBiasPortn | read-only | current | Line Optical Module Laser Bias :This OID gives the Tx Laser Bias value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/50… |
| 1.3.6.1.4.1.20044.70.3.3.128 | Tablepmo6006MesrlineRxPwrTable | not-accessible | current | List of pmo6006MesrlineRxPwr Article |
| 1.3.6.1.4.1.20044.70.3.3.128.1 | Rowpmo6006MesrlineRxPwrEntry | not-accessible | current | Row definition for the pmo6006MesrlineRxPwr table |
| 1.3.6.1.4.1.20044.70.3.3.128.1.1 | Columnpmo6006MesrlineRxPwrIndex | read-only | current | Index definition for the pmo6006MesrlineRxPwr table |
| 1.3.6.1.4.1.20044.70.3.3.128.1.2 | Columnpmo6006MesrlineRxPwrPortn | read-only | current | Line Optical Module Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(A… |
| 1.3.6.1.4.1.20044.70.4 | Nodepmo6006counters | |||
| 1.3.6.1.4.1.20044.70.4.1 | Nodepmo6006CntOther | |||
| 1.3.6.1.4.1.20044.70.4.2 | Nodepmo6006CntClient | |||
| 1.3.6.1.4.1.20044.70.4.2.64 | Tablepmo6006CntclientRemoteBipTable | not-accessible | current | List of pmo6006CntclientRemoteBip Article |
| 1.3.6.1.4.1.20044.70.4.2.64.1 | Rowpmo6006CntclientRemoteBipEntry | not-accessible | current | Row definition for the pmo6006CntclientRemoteBip table |
| 1.3.6.1.4.1.20044.70.4.2.64.1.1 | Columnpmo6006CntclientRemoteBipIndex | read-only | current | Index definition for the pmo6006CntclientRemoteBip table |
| 1.3.6.1.4.1.20044.70.4.2.64.1.2 | Columnpmo6006CntclientRemoteBipValuePortn | read-only | current | ODU2e_Sk_pF_EBC :This counter is increased each time a BIP8 error is detected on the Client input stream <Help> This counter gives the number of BIP8 errors on… |
| 1.3.6.1.4.1.20044.70.4.2.64.1.3 | Columnpmo6006CntclientRemoteBipErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the BIP8 error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.70.4.2.64.1.4 | Columnpmo6006CntclientRemoteBipOverloadPortn | read-only | current | Client Counter Overload :This OID when set indicates a BIP8 error counter overload on Port |
| 1.3.6.1.4.1.20044.70.4.2.96 | Tablepmo6006CntclientCbipCounterTable | not-accessible | current | List of pmo6006CntclientCbipCounter Article |
| 1.3.6.1.4.1.20044.70.4.2.96.1 | Rowpmo6006CntclientCbipCounterEntry | not-accessible | current | Row definition for the pmo6006CntclientCbipCounter table |
| 1.3.6.1.4.1.20044.70.4.2.96.1.1 | Columnpmo6006CntclientCbipCounterIndex | read-only | current | Index definition for the pmo6006CntclientCbipCounter table |
| 1.3.6.1.4.1.20044.70.4.2.96.1.2 | Columnpmo6006CntclientCbipCounterValuePortn | read-only | current | ODU2e_Sk_pN_EBC :This counter is incremented each time a BI8P error is detected on the Client path <Help> This counter gives the number of BIP8 errors on the c… |
| 1.3.6.1.4.1.20044.70.4.2.96.1.3 | Columnpmo6006CntclientCbipCounterErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the CBIP error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.70.4.2.96.1.4 | Columnpmo6006CntclientCbipCounterOverloadPortn | read-only | current | Client CBIP Counter Overload :This OID when set indicates a CBIP error counter overload on Port |
| 1.3.6.1.4.1.20044.70.4.3 | Nodepmo6006CntLine | |||
| 1.3.6.1.4.1.20044.70.4.3.192 | Tablepmo6006CntlocalLineSmBip8ErrorCounterTable | not-accessible | current | List of pmo6006CntlocalLineSmBip8ErrorCounter Article |
| 1.3.6.1.4.1.20044.70.4.3.192.1 | Rowpmo6006CntlocalLineSmBip8ErrorCounterEntry | not-accessible | current | Row definition for the pmo6006CntlocalLineSmBip8ErrorCounter table |
| 1.3.6.1.4.1.20044.70.4.3.192.1.1 | Columnpmo6006CntlocalLineSmBip8ErrorCounterIndex | read-only | current | Index definition for the pmo6006CntlocalLineSmBip8ErrorCounter table |
| 1.3.6.1.4.1.20044.70.4.3.192.1.2 | Columnpmo6006CntlocalLineSmBip8ErrorCounterValuePortn | read-only | current | OTU2e_Sk_pN_EBC :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC <Help> This counter gives the current Bit Error Rate (residual SM… |
| 1.3.6.1.4.1.20044.70.4.3.192.1.3 | Columnpmo6006CntlocalLineSmBip8ErrorCounterErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the B1 error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.70.4.3.192.1.4 | Columnpmo6006CntlocalLineSmBip8ErrorCounterOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a B1 error counter overload on Port |
| 1.3.6.1.4.1.20044.70.4.3.200 | Tablepmo6006CntlocalLineFecCorrectedErrorsCounterTable | not-accessible | current | List of pmo6006CntlocalLineFecCorrectedErrorsCounter Article |
| 1.3.6.1.4.1.20044.70.4.3.200.1 | Rowpmo6006CntlocalLineFecCorrectedErrorsCounterEntry | not-accessible | current | Row definition for the pmo6006CntlocalLineFecCorrectedErrorsCounter table |
| 1.3.6.1.4.1.20044.70.4.3.200.1.1 | Columnpmo6006CntlocalLineFecCorrectedErrorsCounterIndex | read-only | current | Index definition for the pmo6006CntlocalLineFecCorrectedErrorsCounter table |
| 1.3.6.1.4.1.20044.70.4.3.200.1.2 | Columnpmo6006CntlocalLineFecCorrectedErrorsCounterValuePortn | read-only | current | OCh/OTU2e-Sk_pFECcorrErr :This OID gives the current Bit Error Rate before the Hard Decision FEC <Help> This counter gives the current Bit Error Rate before th… |
| 1.3.6.1.4.1.20044.70.4.3.200.1.3 | Columnpmo6006CntlocalLineFecCorrectedErrorsCounterErrorPortn | read-only | current | FEC Counter Error :This bit when set indicates the FEC corrected errors counter value is invalid on Line |
| 1.3.6.1.4.1.20044.70.4.3.200.1.4 | Columnpmo6006CntlocalLineFecCorrectedErrorsCounterOverloadPortn | read-only | current | FEC Counter Overload :This bit when set indicates a FEC corrected errors counter overload on Line |
| 1.3.6.1.4.1.20044.70.4.3.208 | Tablepmo6006CntremoteLineSmBip8ErrorCounterTable | not-accessible | current | List of pmo6006CntremoteLineSmBip8ErrorCounter Article |
| 1.3.6.1.4.1.20044.70.4.3.208.1 | Rowpmo6006CntremoteLineSmBip8ErrorCounterEntry | not-accessible | current | Row definition for the pmo6006CntremoteLineSmBip8ErrorCounter table |
| 1.3.6.1.4.1.20044.70.4.3.208.1.1 | Columnpmo6006CntremoteLineSmBip8ErrorCounterIndex | read-only | current | Index definition for the pmo6006CntremoteLineSmBip8ErrorCounter table |
| 1.3.6.1.4.1.20044.70.4.3.208.1.2 | Columnpmo6006CntremoteLineSmBip8ErrorCounterValuePortn | read-only | current | OTU2e_Sk_pF_EBC :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC on the remote side <Help> This counter gives the current Bit Erro… |
| 1.3.6.1.4.1.20044.70.4.3.208.1.3 | Columnpmo6006CntremoteLineSmBip8ErrorCounterErrorPortn | read-only | current | Remote Counter Error : |
| 1.3.6.1.4.1.20044.70.4.3.208.1.4 | Columnpmo6006CntremoteLineSmBip8ErrorCounterOverloadPortn | read-only | current | Remote Counter Overload : |
| 1.3.6.1.4.1.20044.70.4.3.216 | Tablepmo6006CntlineDfrmTimCntTable | not-accessible | current | List of pmo6006CntlineDfrmTimCnt Article |
| 1.3.6.1.4.1.20044.70.4.3.216.1 | Rowpmo6006CntlineDfrmTimCntEntry | not-accessible | current | Row definition for the pmo6006CntlineDfrmTimCnt table |
| 1.3.6.1.4.1.20044.70.4.3.216.1.1 | Columnpmo6006CntlineDfrmTimCntIndex | read-only | current | Index definition for the pmo6006CntlineDfrmTimCnt table |
| 1.3.6.1.4.1.20044.70.4.3.216.1.2 | Columnpmo6006CntlineDfrmTimCntValuePortn | read-only | current | Line Timer Counter : |
| 1.3.6.1.4.1.20044.70.4.3.216.1.3 | Columnpmo6006CntlineDfrmTimCntErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.70.4.3.216.1.4 | Columnpmo6006CntlineDfrmTimCntOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.70.4.259 | Scalarpmo6006CntCountersReset | read-write | current | Counters Reset:This OID resets and restarts all the counters |
| 1.3.6.1.4.1.20044.70.4.260 | Scalarpmo6006CntCountersStop | read-write | current | Counters stop:This OID stops all the counters |
| 1.3.6.1.4.1.20044.70.6 | Nodepmo6006controlsWrite | |||
| 1.3.6.1.4.1.20044.70.6.1 | Nodepmo6006CtrlOther | |||
| 1.3.6.1.4.1.20044.70.6.1.1 | Nodepmo6006CtrlconfMgnt1 | |||
| 1.3.6.1.4.1.20044.70.6.1.1.1 | Scalarpmo6006CtrlConf1Load1 | read-write | current | Load Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM. |
| 1.3.6.1.4.1.20044.70.6.1.1.2 | Scalarpmo6006CtrlConf2Load1 | read-write | current | Load Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM. |
| 1.3.6.1.4.1.20044.70.6.1.1.10 | Scalarpmo6006CtrlConf2Flash1 | read-write | current | Write Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura… |
| 1.3.6.1.4.1.20044.70.6.1.1.14 | Scalarpmo6006CtrlConf2Clear1 | read-write | current | Clear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o… |
| 1.3.6.1.4.1.20044.70.6.1.4 | Nodepmo6006Ctrlsynth4 | |||
| 1.3.6.1.4.1.20044.70.6.1.4.1 | Scalarpmo6006CtrlCorrelatOn | read-write | current | Enable Alarm Correlation :This OID enables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.70.6.1.4.2 | Scalarpmo6006CtrlCorrelatOff | read-write | current | Disable Alarm Correlation :This OID disables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.70.6.1.5 | Nodepmo6006CtrlswMgnt | |||
| 1.3.6.1.4.1.20044.70.6.1.5.2 | Scalarpmo6006CtrlColdReset | read-write | current | PM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> … |
| 1.3.6.1.4.1.20044.70.6.1.5.3 | Scalarpmo6006CtrlWarmReset | read-write | current | PM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th… |
| 1.3.6.1.4.1.20044.70.6.1.5.5 | Scalarpmo6006CtrlLoadSwBank1 | read-write | current | Set Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW… |
| 1.3.6.1.4.1.20044.70.6.1.5.6 | Scalarpmo6006CtrlLoadSwBank2 | read-write | current | Set Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S… |
| 1.3.6.1.4.1.20044.70.6.1.6 | Nodepmo6006CtrlgwMgnt | |||
| 1.3.6.1.4.1.20044.70.6.1.6.1 | Scalarpmo6006CtrlCurrentGwReset | read-write | current | Active Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting. |
| 1.3.6.1.4.1.20044.70.6.1.6.5 | Scalarpmo6006CtrlLoadGwBank1 | read-write | current | Set Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.70.6.1.6.6 | Scalarpmo6006CtrlLoadGwBank2 | read-write | current | Set Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.70.6.1.6.7 | Scalarpmo6006CtrlLoadGwBank3 | read-write | current | Set Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.70.6.1.6.8 | Scalarpmo6006CtrlLoadGwBank4 | read-write | current | Set Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.70.6.1.192 | Nodepmo6006CtrlledTest | |||
| 1.3.6.1.4.1.20044.70.6.1.192.1 | Scalarpmo6006CtrlGreenLed | read-write | current | Green Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green |
| 1.3.6.1.4.1.20044.70.6.1.192.2 | Scalarpmo6006CtrlRedLed | read-write | current | Red Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red |
| 1.3.6.1.4.1.20044.70.6.1.192.3 | Scalarpmo6006CtrlLedOff | read-write | current | Leds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF |
| 1.3.6.1.4.1.20044.70.6.2 | Nodepmo6006CtrlClient | |||
| 1.3.6.1.4.1.20044.70.6.2.16 | Tablepmo6006CtrlaccessLoopTable | not-accessible | current | List of pmo6006CtrlaccessLoop Article |
| 1.3.6.1.4.1.20044.70.6.2.16.1 | Rowpmo6006CtrlaccessLoopEntry | not-accessible | current | Row definition for the pmo6006CtrlaccessLoop table |
| 1.3.6.1.4.1.20044.70.6.2.16.1.1 | Columnpmo6006CtrlaccessLoopIndex | read-only | current | Index definition for the pmo6006CtrlaccessLoop table |
| 1.3.6.1.4.1.20044.70.6.2.16.1.2 | Columnpmo6006CtrlaccessLoopPortn | read-write | current | Client Facility Loopback :This OID, when set at '1' puts the client port in loopback, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. <Help… |
| 1.3.6.1.4.1.20044.70.6.2.17 | Tablepmo6006CtrlclientLoopToLineTable | not-accessible | current | List of pmo6006CtrlclientLoopToLine Article |
| 1.3.6.1.4.1.20044.70.6.2.17.1 | Rowpmo6006CtrlclientLoopToLineEntry | not-accessible | current | Row definition for the pmo6006CtrlclientLoopToLine table |
| 1.3.6.1.4.1.20044.70.6.2.17.1.1 | Columnpmo6006CtrlclientLoopToLineIndex | read-only | current | Index definition for the pmo6006CtrlclientLoopToLine table |
| 1.3.6.1.4.1.20044.70.6.2.17.1.2 | Columnpmo6006CtrlclientLoopToLinePortn | read-write | current | Client Terminal Loopback :This OID, when set, puts the client port in loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.<Help> This control ena… |
| 1.3.6.1.4.1.20044.70.6.2.21 | Tablepmo6006CtrlcsfUpInsTable | not-accessible | current | List of pmo6006CtrlcsfUpIns Article |
| 1.3.6.1.4.1.20044.70.6.2.21.1 | Rowpmo6006CtrlcsfUpInsEntry | not-accessible | current | Row definition for the pmo6006CtrlcsfUpIns table |
| 1.3.6.1.4.1.20044.70.6.2.21.1.1 | Columnpmo6006CtrlcsfUpInsIndex | read-only | current | Index definition for the pmo6006CtrlcsfUpIns table |
| 1.3.6.1.4.1.20044.70.6.2.21.1.2 | Columnpmo6006CtrlcsfUpInsPortn | read-write | current | Client Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo… |
| 1.3.6.1.4.1.20044.70.6.2.22 | Tablepmo6006CtrlcaisDwInsTable | not-accessible | current | List of pmo6006CtrlcaisDwIns Article |
| 1.3.6.1.4.1.20044.70.6.2.22.1 | Rowpmo6006CtrlcaisDwInsEntry | not-accessible | current | Row definition for the pmo6006CtrlcaisDwIns table |
| 1.3.6.1.4.1.20044.70.6.2.22.1.1 | Columnpmo6006CtrlcaisDwInsIndex | read-only | current | Index definition for the pmo6006CtrlcaisDwIns table |
| 1.3.6.1.4.1.20044.70.6.2.22.1.2 | Columnpmo6006CtrlcaisDwInsPortn | read-write | current | Client AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port |
| 1.3.6.1.4.1.20044.70.6.2.23 | Tablepmo6006CtrlclientOciTable | not-accessible | current | List of pmo6006CtrlclientOci Article |
| 1.3.6.1.4.1.20044.70.6.2.23.1 | Rowpmo6006CtrlclientOciEntry | not-accessible | current | Row definition for the pmo6006CtrlclientOci table |
| 1.3.6.1.4.1.20044.70.6.2.23.1.1 | Columnpmo6006CtrlclientOciIndex | read-only | current | Index definition for the pmo6006CtrlclientOci table |
| 1.3.6.1.4.1.20044.70.6.2.23.1.2 | Columnpmo6006CtrlclientOciPortn | read-write | current | ODU2e-OCI :Label <Help> This control inserts a Client OCI |
| 1.3.6.1.4.1.20044.70.6.2.24 | Tablepmo6006CtrlclientLckTable | not-accessible | current | List of pmo6006CtrlclientLck Article |
| 1.3.6.1.4.1.20044.70.6.2.24.1 | Rowpmo6006CtrlclientLckEntry | not-accessible | current | Row definition for the pmo6006CtrlclientLck table |
| 1.3.6.1.4.1.20044.70.6.2.24.1.1 | Columnpmo6006CtrlclientLckIndex | read-only | current | Index definition for the pmo6006CtrlclientLck table |
| 1.3.6.1.4.1.20044.70.6.2.24.1.2 | Columnpmo6006CtrlclientLckPortn | read-write | current | ODU2e-LCK :Label <Help> This control inserts a Client LCK |
| 1.3.6.1.4.1.20044.70.6.2.25 | Tablepmo6006CtrlclientAisTable | not-accessible | current | List of pmo6006CtrlclientAis Article |
| 1.3.6.1.4.1.20044.70.6.2.25.1 | Rowpmo6006CtrlclientAisEntry | not-accessible | current | Row definition for the pmo6006CtrlclientAis table |
| 1.3.6.1.4.1.20044.70.6.2.25.1.1 | Columnpmo6006CtrlclientAisIndex | read-only | current | Index definition for the pmo6006CtrlclientAis table |
| 1.3.6.1.4.1.20044.70.6.2.25.1.2 | Columnpmo6006CtrlclientAisPortn | read-write | current | ODU2e-AIS :Label <Help> This control inserts a Client AIS |
| 1.3.6.1.4.1.20044.70.6.2.26 | Tablepmo6006CtrlclientBdiTable | not-accessible | current | List of pmo6006CtrlclientBdi Article |
| 1.3.6.1.4.1.20044.70.6.2.26.1 | Rowpmo6006CtrlclientBdiEntry | not-accessible | current | Row definition for the pmo6006CtrlclientBdi table |
| 1.3.6.1.4.1.20044.70.6.2.26.1.1 | Columnpmo6006CtrlclientBdiIndex | read-only | current | Index definition for the pmo6006CtrlclientBdi table |
| 1.3.6.1.4.1.20044.70.6.2.26.1.2 | Columnpmo6006CtrlclientBdiPortn | read-write | current | ODU2e-BDI :Label <Help> This control inserts a Client BDI |
| 1.3.6.1.4.1.20044.70.6.3 | Nodepmo6006CtrlLine | |||
| 1.3.6.1.4.1.20044.70.6.3.64 | Tablepmo6006CtrlcommAccessLoopTable | not-accessible | current | List of pmo6006CtrlcommAccessLoop Article |
| 1.3.6.1.4.1.20044.70.6.3.64.1 | Rowpmo6006CtrlcommAccessLoopEntry | not-accessible | current | Row definition for the pmo6006CtrlcommAccessLoop table |
| 1.3.6.1.4.1.20044.70.6.3.64.1.1 | Columnpmo6006CtrlcommAccessLoopIndex | read-only | current | Index definition for the pmo6006CtrlcommAccessLoop table |
| 1.3.6.1.4.1.20044.70.6.3.64.1.2 | Columnpmo6006CtrlcommAccessLoopPortn | read-write | current | Line Terminal Loopback :This OID, when set, puts the module in common access loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.<Help> This cont… |
| 1.3.6.1.4.1.20044.70.6.3.66 | Tablepmo6006CtrllineLoopTable | not-accessible | current | List of pmo6006CtrllineLoop Article |
| 1.3.6.1.4.1.20044.70.6.3.66.1 | Rowpmo6006CtrllineLoopEntry | not-accessible | current | Row definition for the pmo6006CtrllineLoop table |
| 1.3.6.1.4.1.20044.70.6.3.66.1.1 | Columnpmo6006CtrllineLoopIndex | read-only | current | Index definition for the pmo6006CtrllineLoop table |
| 1.3.6.1.4.1.20044.70.6.3.66.1.2 | Columnpmo6006CtrllineLoopPortn | read-write | current | Line Facility Loopback :This OID, when set at '1' puts the module in line loopback mode, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. Th… |
| 1.3.6.1.4.1.20044.70.6.3.69 | Tablepmo6006CtrlfecDisableTable | not-accessible | current | List of pmo6006CtrlfecDisable Article |
| 1.3.6.1.4.1.20044.70.6.3.69.1 | Rowpmo6006CtrlfecDisableEntry | not-accessible | current | Row definition for the pmo6006CtrlfecDisable table |
| 1.3.6.1.4.1.20044.70.6.3.69.1.1 | Columnpmo6006CtrlfecDisableIndex | read-only | current | Index definition for the pmo6006CtrlfecDisable table |
| 1.3.6.1.4.1.20044.70.6.3.69.1.2 | Columnpmo6006CtrlfecDisablePortn | read-write | current | Forward Error Correction Inhibition :This OID, when set, inhibits the Forward Error Correction feature on the line input <Help> This control enables/disables t… |
| 1.3.6.1.4.1.20044.70.6.3.70 | Tablepmo6006CtrllineBdiTable | not-accessible | current | List of pmo6006CtrllineBdi Article |
| 1.3.6.1.4.1.20044.70.6.3.70.1 | Rowpmo6006CtrllineBdiEntry | not-accessible | current | Row definition for the pmo6006CtrllineBdi table |
| 1.3.6.1.4.1.20044.70.6.3.70.1.1 | Columnpmo6006CtrllineBdiIndex | read-only | current | Index definition for the pmo6006CtrllineBdi table |
| 1.3.6.1.4.1.20044.70.6.3.70.1.2 | Columnpmo6006CtrllineBdiPortn | read-write | current | OTU2e-BDI :Label <Help> This control inserts a Line BDI |
| 1.3.6.1.4.1.20044.70.7 | Nodepmo6006ri | |||
| 1.3.6.1.4.1.20044.70.7.1 | Nodepmo6006riTable | |||
| 1.3.6.1.4.1.20044.70.7.1.1 | Tablepmo6006RinvSfpTable | not-accessible | current | List of the SFPs on the selected module |
| 1.3.6.1.4.1.20044.70.7.1.1.1 | Rowpmo6006RinvSfpEntry | not-accessible | current | Row definition for the SFP table |
| 1.3.6.1.4.1.20044.70.7.1.1.1.1 | Columnpmo6006RinvSfpIndex | read-only | current | Index for SFP table |
| 1.3.6.1.4.1.20044.70.7.1.1.1.2 | Columnpmo6006Rinvsfp | read-only | current | Inventory for the SFP: This OID contains the inventory for the SFP |
| 1.3.6.1.4.1.20044.70.7.1.2 | Tablepmo6006RinvLineTable | not-accessible | current | List of the SFPs on the selected module |
| 1.3.6.1.4.1.20044.70.7.1.2.1 | Rowpmo6006RinvLineEntry | not-accessible | current | Row definition for the SFP table |
| 1.3.6.1.4.1.20044.70.7.1.2.1.1 | Columnpmo6006RinvLineIndex | read-only | current | Index for SFP table |
| 1.3.6.1.4.1.20044.70.7.1.2.1.2 | Columnpmo6006RinvxfpLine | read-only | current | Inventory for the XFP: This OID contains the inventory for the XFP |
| 1.3.6.1.4.1.20044.70.7.2 | Scalarpmo6006RinvReloadInventory | read-write | current | Reload the inventory: This OID triggers an inventory reload. |
| 1.3.6.1.4.1.20044.70.7.3 | Scalarpmo6006RinvHwPlatform | read-only | current | HW platform description: This OID contains the description of the Hardware platform. |
| 1.3.6.1.4.1.20044.70.7.4 | Scalarpmo6006RinvModulePlatform | read-only | current | Module platform description: This OID contains the description of the Module. |
| 1.3.6.1.4.1.20044.70.7.5 | Scalarpmo6006RinvSwPlatform | read-only | current | SW platform description: This OID contains the description of the Software platform. |
| 1.3.6.1.4.1.20044.70.7.6 | Scalarpmo6006RinvGwPlatform | read-only | current | GW platform description: This OID contains the description of the Gateware platform. |
| 1.3.6.1.4.1.20044.70.8 | Nodepmo6006download | |||
| 1.3.6.1.4.1.20044.70.8.1 | Nodepmo6006DwlOther | |||
| 1.3.6.1.4.1.20044.70.8.1.0 | Nodepmo6006DwlrestartProcess | |||
| 1.3.6.1.4.1.20044.70.8.1.0.1 | Scalarpmo6006DwlWarmRestartProcessed | read-only | current | Warm Restart :This OID indicates that the module last restart was a Warm RESTART |
| 1.3.6.1.4.1.20044.70.8.1.0.2 | Scalarpmo6006DwlColdRestartProcessed | read-only | current | Cold Restart :This OID indicates that the module last restart was a Cold RESTART |
| 1.3.6.1.4.1.20044.70.8.1.1 | Nodepmo6006DwlswBanksUsed | |||
| 1.3.6.1.4.1.20044.70.8.1.1.1 | Scalarpmo6006DwlSwBank1Used | read-only | current | SW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.70.8.1.1.2 | Scalarpmo6006DwlSwBank2Used | read-only | current | SW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby |
| 1.3.6.1.4.1.20044.70.8.1.1.5 | Scalarpmo6006DwlSwBank1Notempty | read-only | current | SW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package |
| 1.3.6.1.4.1.20044.70.8.1.1.6 | Scalarpmo6006DwlSwBank2Notempty | read-only | current | SW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package |
| 1.3.6.1.4.1.20044.70.8.1.2 | Nodepmo6006DwlgwBanksUsed | |||
| 1.3.6.1.4.1.20044.70.8.1.2.1 | Scalarpmo6006DwlGwBank1Used | read-only | current | GW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.70.8.1.2.2 | Scalarpmo6006DwlGwBank2Used | read-only | current | GW bank 2 active :This OID indicates the module is working on GW bank 2 |
| 1.3.6.1.4.1.20044.70.8.1.2.3 | Scalarpmo6006DwlGwBank3Used | read-only | current | GW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby |
| 1.3.6.1.4.1.20044.70.8.1.2.4 | Scalarpmo6006DwlGwBank4Used | read-only | current | GW bank 4 active :This OID indicates the module is working on GW bank 4 |
| 1.3.6.1.4.1.20044.70.8.1.2.5 | Scalarpmo6006DwlGwBank1Notempty | read-only | current | GW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package |
| 1.3.6.1.4.1.20044.70.8.1.2.6 | Scalarpmo6006DwlGwBank2Notempty | read-only | current | GW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2 |
| 1.3.6.1.4.1.20044.70.8.1.2.7 | Scalarpmo6006DwlGwBank3Notempty | read-only | current | GW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package |
| 1.3.6.1.4.1.20044.70.8.1.2.8 | Scalarpmo6006DwlGwBank4Notempty | read-only | current | GW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4 |
| 1.3.6.1.4.1.20044.70.8.2 | Nodepmo6006DwlClient | |||
| 1.3.6.1.4.1.20044.70.8.3 | Nodepmo6006DwlLine | |||
| 1.3.6.1.4.1.20044.70.9 | Nodepmo6006Config | |||
| 1.3.6.1.4.1.20044.70.9.1 | Nodepmo6006CfgStartup | |||
| 1.3.6.1.4.1.20044.70.9.1.1 | Tablepmo6006CfgClientStartupTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.70.9.1.1.1 | Rowpmo6006CfgClientStartupEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.70.9.1.1.1.1 | Columnpmo6006CfgClientStartupIndex | read-only | current | Index definition for the clientStartup table |
| 1.3.6.1.4.1.20044.70.9.1.1.1.3 | Columnpmo6006CfgSystConfPortPortn | read-write | current | Default Settings on Client Port :This register configures the default initialisation settings on the port. |
| 1.3.6.1.4.1.20044.70.9.1.1.1.4 | Columnpmo6006CfgNetConfPortPortn | read-write | current | Default Settings on Client Port :This register configures the default initialisation settings on the port. |
| 1.3.6.1.4.1.20044.70.9.1.1.1.14 | Columnpmo6006CfgOptionsPortPortn | read-write | current | Default Options on Client Port :This register configures the default options on the port. |
| 1.3.6.1.4.1.20044.70.9.1.2 | Tablepmo6006CfgLinexr1StartupTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.70.9.1.2.1 | Rowpmo6006CfgLinexr1StartupEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.70.9.1.2.1.1 | Columnpmo6006CfgLinexr1StartupIndex | read-only | current | Index definition for the linexr1Startup table |
| 1.3.6.1.4.1.20044.70.9.1.2.1.3 | Columnpmo6006CfgSystConfLinePortn | read-write | current | Default Settings on Line :This register configures the default initialisation settings on Line |
| 1.3.6.1.4.1.20044.70.9.1.2.1.14 | Columnpmo6006CfgOptionsLinePortn | read-write | current | Default Options on Line :This register configures the default options on the line |
| 1.3.6.1.4.1.20044.70.9.1.3 | Tablepmo6006CfgOtxtlhTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.70.9.1.3.1 | Rowpmo6006CfgOtxtlhEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.70.9.1.3.1.1 | Columnpmo6006CfgOtxtlhIndex | read-only | current | Index definition for the otxtlh table |
| 1.3.6.1.4.1.20044.70.9.1.3.1.3 | Columnpmo6006CfgLineControlsPortn | read-write | deprecated | Default Line settings :This register configures the start-up settings on the ports |
| 1.3.6.1.4.1.20044.70.9.1.3.1.6 | Columnpmo6006CfgLinePwrLaserPortn | read-write | current | Default Line output Power :This register configures the start-up output power of the client transceiver (Unit = dBm) |
| 1.3.6.1.4.1.20044.70.9.1.3.1.7 | Columnpmo6006CfgLineFCurrentPortn | read-write | current | Default Line transceiver Channel :This register configures the start-up laser channel of the client transceiver |
| 1.3.6.1.4.1.20044.70.9.1.3.1.8 | Columnpmo6006CfgLineGridCurrentPortn | read-write | current | Default Line transceiver Grid :This register configures the start-up laser grid of the client transceiver |
| 1.3.6.1.4.1.20044.70.9.1.3.1.9 | Columnpmo6006CfgLineFoPortn | read-write | current | Default Line first Frequency :This register configures the start-up first frequency of the client transceiver |
| 1.3.6.1.4.1.20044.70.9.2 | Nodepmo6006CfgLabels | |||
| 1.3.6.1.4.1.20044.70.9.2.1 | Tablepmo6006CfgLabelclientTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.70.9.2.1.1 | Rowpmo6006CfgLabelclientEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.70.9.2.1.1.1 | Columnpmo6006CfgLabelclientIndex | read-only | current | Index definition for the labelclient table |
| 1.3.6.1.4.1.20044.70.9.2.1.1.3 | Columnpmo6006CfgLabelclientPortn | read-write | current | Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. |
| 1.3.6.1.4.1.20044.70.9.2.2 | Tablepmo6006CfgLabellineTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.70.9.2.2.1 | Rowpmo6006CfgLabellineEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.70.9.2.2.1.1 | Columnpmo6006CfgLabellineIndex | read-only | current | Index definition for the labelline table |
| 1.3.6.1.4.1.20044.70.9.2.2.1.3 | Columnpmo6006CfgLabellinePortn | read-write | current | Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. |
| 1.3.6.1.4.1.20044.70.9.3 | Nodepmo6006CfgOther | |||
| 1.3.6.1.4.1.20044.70.9.3.1 | Nodepmo6006tablemoduleOther | |||
| 1.3.6.1.4.1.20044.70.9.3.1.2 | Scalarpmo6006Cfgmode | read-write | current | Default settings on Module :This register selects the configuration mode of the module |
| 1.3.6.1.4.1.20044.70.9.4 | Nodepmo6006CfgOdu2Clienta | |||
| 1.3.6.1.4.1.20044.70.9.4.1 | Tablepmo6006CfgClientStartupOduTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.70.9.4.1.1 | Rowpmo6006CfgClientStartupOduEntry | not-accessible | current | Row definition for the odu2Clienta table |
| 1.3.6.1.4.1.20044.70.9.4.1.1.1 | Columnpmo6006CfgClientStartupOduIndex | read-only | current | Index definition for the clientStartupOdu table |
| 1.3.6.1.4.1.20044.70.9.4.1.1.3 | Columnpmo6006CfgOdu2ReserveLsbPortn | read-write | current | : |
| 1.3.6.1.4.1.20044.70.9.4.1.1.4 | Columnpmo6006CfgOdu2DegthresholdPortn | read-write | current | ODU2 Degrade Threshold : |
| 1.3.6.1.4.1.20044.70.9.4.1.1.5 | Columnpmo6006CfgOdu2DegmPortn | read-write | current | ODU2 Degrade Confirmation : |
| 1.3.6.1.4.1.20044.70.9.4.1.1.6 | Columnpmo6006CfgOdu2SettingsPortn | read-write | current | ODU2 Settings : |
| 1.3.6.1.4.1.20044.70.9.5 | Nodepmo6006CfgOtu2Line | |||
| 1.3.6.1.4.1.20044.70.9.5.1 | Tablepmo6006CfgLinexStartupOtuTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.70.9.5.1.1 | Rowpmo6006CfgLinexStartupOtuEntry | not-accessible | current | Row definition for the otu2Line table |
| 1.3.6.1.4.1.20044.70.9.5.1.1.1 | Columnpmo6006CfgLinexStartupOtuIndex | read-only | current | Index definition for the linexStartupOtu table |
| 1.3.6.1.4.1.20044.70.9.5.1.1.3 | Columnpmo6006CfgOtu2ReserveMsbPortn | read-write | current | : |
| 1.3.6.1.4.1.20044.70.9.5.1.1.4 | Columnpmo6006CfgOtu2DegthresholdPortn | read-write | current | OTU2 Degrade Threshold : |
| 1.3.6.1.4.1.20044.70.9.5.1.1.5 | Columnpmo6006CfgOtu2DegmPortn | read-write | current | OTU2 Degrade Confirmation : |
| 1.3.6.1.4.1.20044.70.9.5.1.1.6 | Columnpmo6006CfgOtu2SettingsPortn | read-write | current | OTU2 Settings : |
| 1.3.6.1.4.1.20044.70.9.6 | Nodepmo6006CfgSapiTxClient | |||
| 1.3.6.1.4.1.20044.70.9.6.1 | Tablepmo6006CfgClientSapiTxOduTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.70.9.6.1.1 | Rowpmo6006CfgClientSapiTxOduEntry | not-accessible | current | Row definition for the sapiTxClient table |
| 1.3.6.1.4.1.20044.70.9.6.1.1.1 | Columnpmo6006CfgClientSapiTxOduIndex | read-only | current | Index definition for the clientSapiTxOdu table |
| 1.3.6.1.4.1.20044.70.9.6.1.1.3 | Columnpmo6006CfgClientSapiTxSetupPortn | read-write | current | Client Transmitted SAPI :This register defines the value of the transmitted Trace Identifier on the line output |
| 1.3.6.1.4.1.20044.70.9.7 | Nodepmo6006CfgSapiExpClient | |||
| 1.3.6.1.4.1.20044.70.9.7.1 | Tablepmo6006CfgClientSapiExpOduTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.70.9.7.1.1 | Rowpmo6006CfgClientSapiExpOduEntry | not-accessible | current | Row definition for the sapiExpClient table |
| 1.3.6.1.4.1.20044.70.9.7.1.1.1 | Columnpmo6006CfgClientSapiExpOduIndex | read-only | current | Index definition for the clientSapiExpOdu table |
| 1.3.6.1.4.1.20044.70.9.7.1.1.3 | Columnpmo6006CfgClientSapiExpSetupPortn | read-write | current | Client Expected SAPI :This register defines the value of the expected Trace Identifier on the line input |
| 1.3.6.1.4.1.20044.70.9.8 | Nodepmo6006CfgSapiAccClient | |||
| 1.3.6.1.4.1.20044.70.9.8.1 | Tablepmo6006CfgClientSapiAccOduTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.70.9.8.1.1 | Rowpmo6006CfgClientSapiAccOduEntry | not-accessible | current | Row definition for the sapiAccClient table |
| 1.3.6.1.4.1.20044.70.9.8.1.1.1 | Columnpmo6006CfgClientSapiAccOduIndex | read-only | current | Index definition for the clientSapiAccOdu table |
| 1.3.6.1.4.1.20044.70.9.8.1.1.3 | Columnpmo6006CfgClientSapiAccSetupPortn | read-write | deprecated | Client Accepted SAPI :This register defines the value of the accepted Trace Identifier on the line input |
| 1.3.6.1.4.1.20044.70.9.9 | Nodepmo6006CfgDapiTxClient | |||
| 1.3.6.1.4.1.20044.70.9.9.1 | Tablepmo6006CfgClientDapiTxOduTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.70.9.9.1.1 | Rowpmo6006CfgClientDapiTxOduEntry | not-accessible | current | Row definition for the dapiTxClient table |
| 1.3.6.1.4.1.20044.70.9.9.1.1.1 | Columnpmo6006CfgClientDapiTxOduIndex | read-only | current | Index definition for the clientDapiTxOdu table |
| 1.3.6.1.4.1.20044.70.9.9.1.1.3 | Columnpmo6006CfgClientDapiTxSetupPortn | read-write | current | Client Transmitted DAPI :This register defines the value of the transmitted Trace Identifier on the line output |
| 1.3.6.1.4.1.20044.70.9.10 | Nodepmo6006CfgDapiExpClient | |||
| 1.3.6.1.4.1.20044.70.9.10.1 | Tablepmo6006CfgClientDapiExpOduTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.70.9.10.1.1 | Rowpmo6006CfgClientDapiExpOduEntry | not-accessible | current | Row definition for the dapiExpClient table |
| 1.3.6.1.4.1.20044.70.9.10.1.1.1 | Columnpmo6006CfgClientDapiExpOduIndex | read-only | current | Index definition for the clientDapiExpOdu table |
| 1.3.6.1.4.1.20044.70.9.10.1.1.3 | Columnpmo6006CfgClientDapiExpSetupPortn | read-write | current | Client Expected DAPI :This register defines the value of the expected Trace Identifier on the line input |
| 1.3.6.1.4.1.20044.70.9.11 | Nodepmo6006CfgDapiAccClient | |||
| 1.3.6.1.4.1.20044.70.9.11.1 | Tablepmo6006CfgClientDapiAccOduTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.70.9.11.1.1 | Rowpmo6006CfgClientDapiAccOduEntry | not-accessible | current | Row definition for the dapiAccClient table |
| 1.3.6.1.4.1.20044.70.9.11.1.1.1 | Columnpmo6006CfgClientDapiAccOduIndex | read-only | current | Index definition for the clientDapiAccOdu table |
| 1.3.6.1.4.1.20044.70.9.11.1.1.3 | Columnpmo6006CfgClientDapiAccSetupPortn | read-write | deprecated | Client Accepted DAPI :This register defines the value of the accepted Trace Identifier on the line input |
| 1.3.6.1.4.1.20044.70.9.12 | Nodepmo6006CfgSapiTxLine | |||
| 1.3.6.1.4.1.20044.70.9.12.1 | Tablepmo6006CfgLineSapiTxOtuTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.70.9.12.1.1 | Rowpmo6006CfgLineSapiTxOtuEntry | not-accessible | current | Row definition for the sapiTxLine table |
| 1.3.6.1.4.1.20044.70.9.12.1.1.1 | Columnpmo6006CfgLineSapiTxOtuIndex | read-only | current | Index definition for the lineSapiTxOtu table |
| 1.3.6.1.4.1.20044.70.9.12.1.1.3 | Columnpmo6006CfgLineSapiTxSetupPortn | read-write | current | Line Transmitted SAPI :This register defines the value of the transmitted Trace Identifier on the line output |
| 1.3.6.1.4.1.20044.70.9.13 | Nodepmo6006CfgSapiExpLine | |||
| 1.3.6.1.4.1.20044.70.9.13.1 | Tablepmo6006CfgLineSapiExpOtuTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.70.9.13.1.1 | Rowpmo6006CfgLineSapiExpOtuEntry | not-accessible | current | Row definition for the sapiExpLine table |
| 1.3.6.1.4.1.20044.70.9.13.1.1.1 | Columnpmo6006CfgLineSapiExpOtuIndex | read-only | current | Index definition for the lineSapiExpOtu table |
| 1.3.6.1.4.1.20044.70.9.13.1.1.3 | Columnpmo6006CfgLineSapiExpSetupPortn | read-write | current | Line Expected SAPI :This register defines the value of the expected Trace Identifier on the line input |
| 1.3.6.1.4.1.20044.70.9.14 | Nodepmo6006CfgSapiAccLine | |||
| 1.3.6.1.4.1.20044.70.9.14.1 | Tablepmo6006CfgLineSapiAccOtuTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.70.9.14.1.1 | Rowpmo6006CfgLineSapiAccOtuEntry | not-accessible | current | Row definition for the sapiAccLine table |
| 1.3.6.1.4.1.20044.70.9.14.1.1.1 | Columnpmo6006CfgLineSapiAccOtuIndex | read-only | current | Index definition for the lineSapiAccOtu table |
| 1.3.6.1.4.1.20044.70.9.14.1.1.3 | Columnpmo6006CfgLineSapiAccSetupPortn | read-write | deprecated | Line Accepted SAPI :This register defines the value of the accepted Trace Identifier on the line input |
| 1.3.6.1.4.1.20044.70.9.15 | Nodepmo6006CfgDapiTxLine | |||
| 1.3.6.1.4.1.20044.70.9.15.1 | Tablepmo6006CfgLineDapiTxOtuTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.70.9.15.1.1 | Rowpmo6006CfgLineDapiTxOtuEntry | not-accessible | current | Row definition for the dapiTxLine table |
| 1.3.6.1.4.1.20044.70.9.15.1.1.1 | Columnpmo6006CfgLineDapiTxOtuIndex | read-only | current | Index definition for the lineDapiTxOtu table |
| 1.3.6.1.4.1.20044.70.9.15.1.1.3 | Columnpmo6006CfgLineDapiTxSetupPortn | read-write | current | Line Transmitted DAPI :This register defines the value of the transmitted Trace Identifier on the line output |
| 1.3.6.1.4.1.20044.70.9.16 | Nodepmo6006CfgDapiExpLine | |||
| 1.3.6.1.4.1.20044.70.9.16.1 | Tablepmo6006CfgLineDapiExpOtuTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.70.9.16.1.1 | Rowpmo6006CfgLineDapiExpOtuEntry | not-accessible | current | Row definition for the dapiExpLine table |
| 1.3.6.1.4.1.20044.70.9.16.1.1.1 | Columnpmo6006CfgLineDapiExpOtuIndex | read-only | current | Index definition for the lineDapiExpOtu table |
| 1.3.6.1.4.1.20044.70.9.16.1.1.3 | Columnpmo6006CfgLineDapiExpSetupPortn | read-write | current | Line Expected DAPI :This register defines the value of the expected Trace Identifier on the line input |
| 1.3.6.1.4.1.20044.70.9.17 | Nodepmo6006CfgDapiAccLine | |||
| 1.3.6.1.4.1.20044.70.9.17.1 | Tablepmo6006CfgLineDapiAccOtuTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.70.9.17.1.1 | Rowpmo6006CfgLineDapiAccOtuEntry | not-accessible | current | Row definition for the dapiAccLine table |
| 1.3.6.1.4.1.20044.70.9.17.1.1.1 | Columnpmo6006CfgLineDapiAccOtuIndex | read-only | current | Index definition for the lineDapiAccOtu table |
| 1.3.6.1.4.1.20044.70.9.17.1.1.3 | Columnpmo6006CfgLineDapiAccSetupPortn | read-write | deprecated | Line Accepted DAPI :This register defines the value of the accepted Trace Identifier on the line input |
| 1.3.6.1.4.1.20044.70.9.18 | Nodepmo6006CfgStartuptablefive | |||
| 1.3.6.1.4.1.20044.70.9.18.1 | Tablepmo6006CfgOtxtlhcapabilitiesTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.70.9.18.1.1 | Rowpmo6006CfgOtxtlhcapabilitiesEntry | not-accessible | current | Row definition for the startuptablefive table |
| 1.3.6.1.4.1.20044.70.9.18.1.1.1 | Columnpmo6006CfgOtxtlhcapabilitiesIndex | read-only | current | Index definition for the otxtlhcapabilities table |
| 1.3.6.1.4.1.20044.70.9.18.1.1.3 | Columnpmo6006CfgComponentTypePortn | read-only | current | Component parameters :This OID defines the component parameters |
| 1.3.6.1.4.1.20044.70.9.18.1.1.4 | Columnpmo6006CfgMiscellaneousPortn | read-only | current | Miscellaneous default settings :This OID defines the miscellaneous parameters |
| 1.3.6.1.4.1.20044.70.9.18.1.1.5 | Columnpmo6006CfgFirstChannelPortn | read-only | current | Number of the first channel of the component :This OID defines the first channel number of the PM |
| 1.3.6.1.4.1.20044.70.9.18.1.1.6 | Columnpmo6006CfgLastChannelPortn | read-only | current | Number of the last channel of the component :This OID defines the last channel number of the PM |
| 1.3.6.1.4.1.20044.70.9.18.1.1.7 | Columnpmo6006CfgGridPortn | read-only | current | Grid value of the component :This OID defines the grid of the PM |
| 1.3.6.1.4.1.20044.70.9.257 | Scalarpmo6006CfgWriteConfiguration | read-write | current | Write configuration to module:This OID writes the complete configuration to the module |
| 1.3.6.1.4.1.20044.70.10 | Nodepmo6006traps | |||
| 1.3.6.1.4.1.20044.70.10.2 | Scalarpmo6006trapPortNumber | read-only | current | Last port which generates a trap |
| 1.3.6.1.4.1.20044.70.10.3 | Scalarpmo6006trapLineNumber | read-only | current | Last Line which generates a trap |
| 1.3.6.1.4.1.20044.70.10.4 | Scalarpmo6006trapBoardNumber | read-only | current | Last module which generates a trap |
| 1.3.6.1.4.1.20044.70.10.30 | Notificationpmo6006LineTrapNotUrgentGoesOn | current | Not urgent Line default is activated | |
| 1.3.6.1.4.1.20044.70.10.31 | Notificationpmo6006LineTrapNotUrgentGoesOff | current | Not urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.70.10.32 | Notificationpmo6006LineTrapUrgentGoesOn | current | Urgent Line default is activated | |
| 1.3.6.1.4.1.20044.70.10.33 | Notificationpmo6006LineTrapUrgentGoesOff | current | Urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.70.10.34 | Notificationpmo6006LineTrapCritGoesOn | current | Critical Line default is activated | |
| 1.3.6.1.4.1.20044.70.10.35 | Notificationpmo6006LineTrapCritGoesOff | current | Critical Line default disappeared | |
| 1.3.6.1.4.1.20044.70.10.40 | Notificationpmo6006ClientTrapNotUrgentGoesOn | current | Not urgent client default is activated | |
| 1.3.6.1.4.1.20044.70.10.41 | Notificationpmo6006ClientTrapNotUrgentGoesOff | current | Not urgent client default disappeared | |
| 1.3.6.1.4.1.20044.70.10.42 | Notificationpmo6006ClientTrapUrgentGoesOn | current | Urgent client default is activated | |
| 1.3.6.1.4.1.20044.70.10.43 | Notificationpmo6006ClientTrapUrgentGoesOff | current | Urgent client default disappeared | |
| 1.3.6.1.4.1.20044.70.10.44 | Notificationpmo6006ClientTrapCritGoesOn | current | Critical client default is activated | |
| 1.3.6.1.4.1.20044.70.10.45 | Notificationpmo6006ClientTrapCritGoesOff | current | Critical client default disappeared | |
| 1.3.6.1.4.1.20044.70.10.50 | Notificationpmo6006PowerTrapUrgentGoesOn | current | Urgent power supply default is activated | |
| 1.3.6.1.4.1.20044.70.10.51 | Notificationpmo6006PowerTrapUrgentGoesOff | current | Urgent power supply default disappeared | |
| 1.3.6.1.4.1.20044.70.11 | Nodepmo6006Monitoring | |||
| 1.3.6.1.4.1.20044.70.11.1 | Nodepmo6006MonOther | |||
| 1.3.6.1.4.1.20044.70.11.1.3 | Nodepmo6006MonRmon | |||
| 1.3.6.1.4.1.20044.70.11.1.3.359 | Scalarpmo6006MonCountersReset | read-write | current | RMON Counters Reset:This OID resets and restarts all the RMON counters |
| 1.3.6.1.4.1.20044.70.11.1.3.360 | Scalarpmo6006MonCountersStop | read-write | current | RMON Counters stop:This OID stops all the RMON counters |
| 1.3.6.1.4.1.20044.70.11.2 | Nodepmo6006MonClient | |||
| 1.3.6.1.4.1.20044.70.11.2.4 | Nodepmo6006MonClientRmonCounter | |||
| 1.3.6.1.4.1.20044.70.11.2.4.16 | Tablepmo6006MonupRmonBytesCounterClientInputTable | not-accessible | current | List of pmo6006MonupRmonBytesCounterClientInput Article |
| 1.3.6.1.4.1.20044.70.11.2.4.16.1 | Rowpmo6006MonupRmonBytesCounterClientInputEntry | not-accessible | current | Row definition for the pmo6006MonupRmonBytesCounterClientInput table |
| 1.3.6.1.4.1.20044.70.11.2.4.16.1.1 | Columnpmo6006MonupRmonBytesCounterClientInputIndex | read-only | current | Index definition for the pmo6006MonupRmonBytesCounterClientInput table |
| 1.3.6.1.4.1.20044.70.11.2.4.16.1.2 | Columnpmo6006MonupRmonBytesCounterClientInputValuePortn | read-only | current | Client Input Bytes :This counter is increased each time a data byte is received on the client port <Help> This counter gives the number of bytes received on th… |
| 1.3.6.1.4.1.20044.70.11.2.4.16.1.3 | Columnpmo6006MonupRmonBytesCounterClientInputErrorPortn | read-only | current | Bytes Counter Error :This OID when set indicates the Bytes counter value is invalid on client port |
| 1.3.6.1.4.1.20044.70.11.2.4.16.1.4 | Columnpmo6006MonupRmonBytesCounterClientInputOverloadPortn | read-only | current | Bytes Counter Overload :This OID when set indicates a Bytes counter overload on client port |
| 1.3.6.1.4.1.20044.70.11.2.4.32 | Tablepmo6006MonupRmonCrcErrorsCounterClientInputTable | not-accessible | current | List of pmo6006MonupRmonCrcErrorsCounterClientInput Article |
| 1.3.6.1.4.1.20044.70.11.2.4.32.1 | Rowpmo6006MonupRmonCrcErrorsCounterClientInputEntry | not-accessible | current | Row definition for the pmo6006MonupRmonCrcErrorsCounterClientInput table |
| 1.3.6.1.4.1.20044.70.11.2.4.32.1.1 | Columnpmo6006MonupRmonCrcErrorsCounterClientInputIndex | read-only | current | Index definition for the pmo6006MonupRmonCrcErrorsCounterClientInput table |
| 1.3.6.1.4.1.20044.70.11.2.4.32.1.2 | Columnpmo6006MonupRmonCrcErrorsCounterClientInputValuePortn | read-only | current | Client Input CRC Errors :This counter is increased each time a B1/FCS error is detected on the client port <Help> This counter gives the number of B1/FCS Error… |
| 1.3.6.1.4.1.20044.70.11.2.4.32.1.3 | Columnpmo6006MonupRmonCrcErrorsCounterClientInputErrorPortn | read-only | current | B1/FCS Errors Counter Error :This OID when set indicates the B1/FCS Errors counter value is invalid on client port |
| 1.3.6.1.4.1.20044.70.11.2.4.32.1.4 | Columnpmo6006MonupRmonCrcErrorsCounterClientInputOverloadPortn | read-only | current | B1/FCS Errors Counter Overload :This OID when set indicates a B1/FCS Errors counter overload on client port |
| 1.3.6.1.4.1.20044.70.11.2.4.48 | Tablepmo6006MonupRmonPacketsCounterClientInputTable | not-accessible | current | List of pmo6006MonupRmonPacketsCounterClientInput Article |
| 1.3.6.1.4.1.20044.70.11.2.4.48.1 | Rowpmo6006MonupRmonPacketsCounterClientInputEntry | not-accessible | current | Row definition for the pmo6006MonupRmonPacketsCounterClientInput table |
| 1.3.6.1.4.1.20044.70.11.2.4.48.1.1 | Columnpmo6006MonupRmonPacketsCounterClientInputIndex | read-only | current | Index definition for the pmo6006MonupRmonPacketsCounterClientInput table |
| 1.3.6.1.4.1.20044.70.11.2.4.48.1.2 | Columnpmo6006MonupRmonPacketsCounterClientInputValuePortn | read-only | current | Client Input Packets :This counter is increased each time a packet is received on the client port <Help> This counter gives the number of packets received on t… |
| 1.3.6.1.4.1.20044.70.11.2.4.48.1.3 | Columnpmo6006MonupRmonPacketsCounterClientInputErrorPortn | read-only | current | Packets Counter Error :This OID when set indicates the Packets counter value is invalid on client port |
| 1.3.6.1.4.1.20044.70.11.2.4.48.1.4 | Columnpmo6006MonupRmonPacketsCounterClientInputOverloadPortn | read-only | current | Packets Counter Overload :This OID when set indicates a Packets counter overload on client port |
| 1.3.6.1.4.1.20044.70.11.2.4.64 | Tablepmo6006MonupRmonBroadcastCounterClientInputTable | not-accessible | current | List of pmo6006MonupRmonBroadcastCounterClientInput Article |
| 1.3.6.1.4.1.20044.70.11.2.4.64.1 | Rowpmo6006MonupRmonBroadcastCounterClientInputEntry | not-accessible | current | Row definition for the pmo6006MonupRmonBroadcastCounterClientInput table |
| 1.3.6.1.4.1.20044.70.11.2.4.64.1.1 | Columnpmo6006MonupRmonBroadcastCounterClientInputIndex | read-only | current | Index definition for the pmo6006MonupRmonBroadcastCounterClientInput table |
| 1.3.6.1.4.1.20044.70.11.2.4.64.1.2 | Columnpmo6006MonupRmonBroadcastCounterClientInputValuePortn | read-only | current | Client Input Broadcast Packets :This counter is increased each time a broadcast packet is received on the client port <Help> This counter gives the number of B… |
| 1.3.6.1.4.1.20044.70.11.2.4.64.1.3 | Columnpmo6006MonupRmonBroadcastCounterClientInputErrorPortn | read-only | current | Broadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.70.11.2.4.64.1.4 | Columnpmo6006MonupRmonBroadcastCounterClientInputOverloadPortn | read-only | current | Broadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port |
| 1.3.6.1.4.1.20044.70.11.2.4.80 | Tablepmo6006MonupRmonMulticastCounterClientInputTable | not-accessible | current | List of pmo6006MonupRmonMulticastCounterClientInput Article |
| 1.3.6.1.4.1.20044.70.11.2.4.80.1 | Rowpmo6006MonupRmonMulticastCounterClientInputEntry | not-accessible | current | Row definition for the pmo6006MonupRmonMulticastCounterClientInput table |
| 1.3.6.1.4.1.20044.70.11.2.4.80.1.1 | Columnpmo6006MonupRmonMulticastCounterClientInputIndex | read-only | current | Index definition for the pmo6006MonupRmonMulticastCounterClientInput table |
| 1.3.6.1.4.1.20044.70.11.2.4.80.1.2 | Columnpmo6006MonupRmonMulticastCounterClientInputValuePortn | read-only | current | Client Input Multicast Packets :This counter is increased each time a Multicast packet is received on the client port <Help> This counter gives the number of M… |
| 1.3.6.1.4.1.20044.70.11.2.4.80.1.3 | Columnpmo6006MonupRmonMulticastCounterClientInputErrorPortn | read-only | current | Multicast Counter Error :This OID when set indicates the Multicast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.70.11.2.4.80.1.4 | Columnpmo6006MonupRmonMulticastCounterClientInputOverloadPortn | read-only | current | Multicast Counter Overload :This OID when set indicates a Multicast counter overload on client port |
| 1.3.6.1.4.1.20044.70.11.2.4.96 | Tablepmo6006MonupRmonPauseFrameCounterClientInputTable | not-accessible | current | List of pmo6006MonupRmonPauseFrameCounterClientInput Article |
| 1.3.6.1.4.1.20044.70.11.2.4.96.1 | Rowpmo6006MonupRmonPauseFrameCounterClientInputEntry | not-accessible | current | Row definition for the pmo6006MonupRmonPauseFrameCounterClientInput table |
| 1.3.6.1.4.1.20044.70.11.2.4.96.1.1 | Columnpmo6006MonupRmonPauseFrameCounterClientInputIndex | read-only | current | Index definition for the pmo6006MonupRmonPauseFrameCounterClientInput table |
| 1.3.6.1.4.1.20044.70.11.2.4.96.1.2 | Columnpmo6006MonupRmonPauseFrameCounterClientInputValuePortn | read-only | current | Client Input Pause Frames :This counter is increased each time a Pause frame is received on the client port <Help> This counter gives the number of Pause frame… |
| 1.3.6.1.4.1.20044.70.11.2.4.96.1.3 | Columnpmo6006MonupRmonPauseFrameCounterClientInputErrorPortn | read-only | current | Pause Counter Error :This OID when set indicates the Pause counter value is invalid on client port |
| 1.3.6.1.4.1.20044.70.11.2.4.96.1.4 | Columnpmo6006MonupRmonPauseFrameCounterClientInputOverloadPortn | read-only | current | Pause Counter Overload :This OID when set indicates a Pause counter overload on client port |
| 1.3.6.1.4.1.20044.70.11.2.4.224 | Tablepmo6006MondwRmonCrcErrorsCounterClientInputTable | not-accessible | current | List of pmo6006MondwRmonCrcErrorsCounterClientInput Article |
| 1.3.6.1.4.1.20044.70.11.2.4.224.1 | Rowpmo6006MondwRmonCrcErrorsCounterClientInputEntry | not-accessible | current | Row definition for the pmo6006MondwRmonCrcErrorsCounterClientInput table |
| 1.3.6.1.4.1.20044.70.11.2.4.224.1.1 | Columnpmo6006MondwRmonCrcErrorsCounterClientInputIndex | read-only | current | Index definition for the pmo6006MondwRmonCrcErrorsCounterClientInput table |
| 1.3.6.1.4.1.20044.70.11.2.4.224.1.2 | Columnpmo6006MondwRmonCrcErrorsCounterClientInputValuePortn | read-only | current | Client Output B1/CRC Errors :This counter is increased each time a B1/FCS error is detected on the output client port <Help> This counter gives the number of B… |
| 1.3.6.1.4.1.20044.70.11.2.4.224.1.3 | Columnpmo6006MondwRmonCrcErrorsCounterClientInputErrorPortn | read-only | current | Output B1/FCS Errors Counter Error :This OID when set indicates the output B1/FCS Errors counter value is invalid on client port |
| 1.3.6.1.4.1.20044.70.11.2.4.224.1.4 | Columnpmo6006MondwRmonCrcErrorsCounterClientInputOverloadPortn | read-only | current | Output B1/FCS Errors Counter Overload :This OID when set indicates an output B1/FCS Errors counter overload on client port |
| 1.3.6.1.4.1.20044.70.11.2.4.240 | Tablepmo6006MondwRmonPacketsCounterClientInputTable | not-accessible | current | List of pmo6006MondwRmonPacketsCounterClientInput Article |
| 1.3.6.1.4.1.20044.70.11.2.4.240.1 | Rowpmo6006MondwRmonPacketsCounterClientInputEntry | not-accessible | current | Row definition for the pmo6006MondwRmonPacketsCounterClientInput table |
| 1.3.6.1.4.1.20044.70.11.2.4.240.1.1 | Columnpmo6006MondwRmonPacketsCounterClientInputIndex | read-only | current | Index definition for the pmo6006MondwRmonPacketsCounterClientInput table |
| 1.3.6.1.4.1.20044.70.11.2.4.240.1.2 | Columnpmo6006MondwRmonPacketsCounterClientInputValuePortn | read-only | current | Client Output Packets :This counter is increased each time a packet is transmitted on the client port. <Help> This counter gives the number of packets detected… |
| 1.3.6.1.4.1.20044.70.11.2.4.240.1.3 | Columnpmo6006MondwRmonPacketsCounterClientInputErrorPortn | read-only | current | Output Packets Counter Error :This OID when set indicates the output Packets counter value is invalid on client port |
| 1.3.6.1.4.1.20044.70.11.2.4.240.1.4 | Columnpmo6006MondwRmonPacketsCounterClientInputOverloadPortn | read-only | current | Output Packets Counter Overload :This OID when set indicates an output Packets counter overload on client port |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| Pmo6006DccMode | INTEGER { dccNo(0), dccLine1(1), dccLine2(2) } | current | Mode for DCC |
| Pmo6006LineChannel | INTEGER | current | Channel selection on transceiver Line ports |
| Pmo6006Odu2SapiMode | INTEGER { off(0), sapi(1) dapi(2) sapidapi(3), } | current | Mode for SAPI-DAPI |
| Pmo6006Otu2SapiMode | INTEGER { off(0), sapi(1) dapi(2) sapidapi(3), } | current | Mode for SAPI-DAPI |
| Pmo6006OtxGrid | INTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50) } | current | Different grids on client and line ports |