OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.61IdentitymodulepmoabphcsCreation
1.3.6.1.4.1.20044.61.2Nodepmoabphcsalarms
1.3.6.1.4.1.20044.61.2.1NodepmoabphcsAlmOther
1.3.6.1.4.1.20044.61.2.1.1NodepmoabphcsAlmOtherNurg
1.3.6.1.4.1.20044.61.2.1.1.2NodepmoabphcsAlmsynthAlm2
1.3.6.1.4.1.20044.61.2.1.1.2.1ScalarpmoabphcsAlmConfTableSaveread-onlycurrentPM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> other…
1.3.6.1.4.1.20044.61.2.1.1.2.2ScalarpmoabphcsAlmInvUploadread-onlycurrentInventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> other (1) <Alarmtype> other (1) <Polarit…
1.3.6.1.4.1.20044.61.2.1.1.2.3ScalarpmoabphcsAlmConfTableLoadread-onlycurrentPM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> other (1) <Alarmt…
1.3.6.1.4.1.20044.61.2.1.1.75NodepmoabphcsAlmfoaWarnings
1.3.6.1.4.1.20044.61.2.1.1.75.7ScalarpmoabphcsAlmTermpLowWarningread-onlycurrentTemperature Low Warning :This OID indicates that the PM temperature if lower than the Warning threshold <Condtype> TERMP_LOW_WARNING <Probcause> temperatureUna…
1.3.6.1.4.1.20044.61.2.1.1.75.8ScalarpmoabphcsAlmTempHighWarningread-onlycurrentTemperature High Warning :This OID indicates that the PM temperature if higher than the Warning threshold <Condtype> TEMP_HIGH_WARNING <Probcause> temperatureU…
1.3.6.1.4.1.20044.61.2.1.2NodepmoabphcsAlmOtherUrg
1.3.6.1.4.1.20044.61.2.1.2.74NodepmoabphcsAlmfoaAlarms
1.3.6.1.4.1.20044.61.2.1.2.74.7ScalarpmoabphcsAlmTermpLowAlarmread-onlycurrentTemperature Low Alarm :This OID indicates that the PM temperature if lower than the alarm threshold <Condtype> TERMP_LOW_ALARM <Probcause> temperatureUnaccepta…
1.3.6.1.4.1.20044.61.2.1.2.74.8ScalarpmoabphcsAlmTempHighAlarmread-onlycurrentTemperature High Alarm :This OID indicates that the PM temperature is higher than the alarm threshold <Condtype> TEMP_HIGH_ALARM <Probcause> temperatureUnaccep…
1.3.6.1.4.1.20044.61.2.1.3NodepmoabphcsAlmOtherCrit
1.3.6.1.4.1.20044.61.2.1.3.0NodepmoabphcsAlmsynthAlm0
1.3.6.1.4.1.20044.61.2.1.3.0.1ScalarpmoabphcsAlmMaintenanceModeread-onlycurrentMaintenance Mode :This OID indicates that the PM is in maintenance mode <Help> This status indiates if the module is currently in maintenance mode <Condtype> M…
1.3.6.1.4.1.20044.61.2.1.3.0.2ScalarpmoabphcsAlmAprOnread-onlycurrentAutomatic Power Reduction :This OID indicates that the APR algorithm has been operated and the output of the lasers are shutdown <Help> The APR algorithm has b…
1.3.6.1.4.1.20044.61.2.1.3.0.9ScalarpmoabphcsAlmModGlobFailread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the PM <Condtype> MOD_GLOB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> sy…
1.3.6.1.4.1.20044.61.2.1.3.0.10ScalarpmoabphcsAlmUpEdfaInitNotComplread-onlycurrentBooster Not Initialized :This OID indicates that the initialisation of the Booster is not completed <Help> This status indicates if the Booster has been correc…
1.3.6.1.4.1.20044.61.2.1.3.0.11ScalarpmoabphcsAlmDwEdfaInitNotComplread-onlycurrentPre-Amp Not Initialized :This OID indicates that the initialisation of the Pre-Amp is not completed <Help> This status indicates if the Pre-Amp has been correc…
1.3.6.1.4.1.20044.61.2.1.3.0.12ScalarpmoabphcsAlmExtPump1NotLockedread-onlycurrentExternal Pump Not Detected :This OID indicates that the first external pump is not detected by the amplifier module <Help> This alarm indicates if the external…
1.3.6.1.4.1.20044.61.2.1.3.0.15ScalarpmoabphcsAlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.61.2.1.3.0.16ScalarpmoabphcsAlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.61.2.2NodepmoabphcsAlmClient
1.3.6.1.4.1.20044.61.2.2.1NodepmoabphcsAlmClientNurg
1.3.6.1.4.1.20044.61.2.2.1.33NodepmoabphcsAlmclientEdfaWarnings
1.3.6.1.4.1.20044.61.2.2.1.33.1ScalarpmoabphcsAlmClientGainLowWarningread-onlycurrentPre-Amp Gain Low Warning :This OID indicates that the Gain is lower than the Warning threshold of the Pre-Amp Module <Help> This alarm indicates if the Pre-Amp…
1.3.6.1.4.1.20044.61.2.2.1.33.2ScalarpmoabphcsAlmClientGainHighWarningread-onlycurrentPre-Amp Gain High Warning :This OID indicates that the Gain is higher than the Warning threshold of the Pre-Amp Module <Help> This alarm indicates if the Pre-A…
1.3.6.1.4.1.20044.61.2.2.1.33.3ScalarpmoabphcsAlmClientInputPwrLowWarningread-onlycurrentPre-Amp Rx Pwr Low Warning :This OID indicates that the Receive Power is lower than the Warning threshold of the Pre-Amp Optical Module <Help> This warning ind…
1.3.6.1.4.1.20044.61.2.2.1.33.4ScalarpmoabphcsAlmClientInputPwrHighWarningread-onlycurrentPre-Amp Rx Pwr High Warning :This OID indicates that the Receive Power is higher than the Warning threshold of the Pre-Amp Optical Module <Help> This warning i…
1.3.6.1.4.1.20044.61.2.2.1.33.5ScalarpmoabphcsAlmClientOutputPwrLowWarningread-onlycurrentPre-Amp Tx Pwr Low Warning :This OID indicates that the Transmit Power is lower than the Warning threshold of the Pre-Amp Optical Module <Help> This warning in…
1.3.6.1.4.1.20044.61.2.2.1.33.6ScalarpmoabphcsAlmClientOutputPwrHighWarningread-onlycurrentPre-Amp Tx Pwr High Warning :This OID indicates that the Transmit Power is higher than the Warning threshold of the Pre-Amp Optical Module <Help> This warning …
1.3.6.1.4.1.20044.61.2.2.1.33.7ScalarpmoabphcsAlmClientBiasLowWarningread-onlycurrentPre-Amp Bias Low Warning :This OID indicates that the Bias is lower than the Warning threshold of the Pre-Amp Optical Module <Help> This warning indicates if t…
1.3.6.1.4.1.20044.61.2.2.1.33.8ScalarpmoabphcsAlmClientBiasHighWarningread-onlycurrentPre-Amp Bias High Warning :This OID indicates that the Bias is higher than the Warning threshold of the Pre-Amp Optical Module <Help> This warning indicates if…
1.3.6.1.4.1.20044.61.2.2.2NodepmoabphcsAlmClientUrg
1.3.6.1.4.1.20044.61.2.2.2.32NodepmoabphcsAlmclientEdfaAlarms1
1.3.6.1.4.1.20044.61.2.2.2.32.1ScalarpmoabphcsAlmClientGainLowAlarmread-onlycurrentPre-Amp Gain Low Alarm :This OID indicates that the Gain is lower than the alarm threshold of the Pre-Amp Module <Help> This alarm indicates if the Pre-Amp gai…
1.3.6.1.4.1.20044.61.2.2.2.32.2ScalarpmoabphcsAlmClientGainHighAlarmread-onlycurrentPre-Amp Gain High Alarm :This OID indicates that the Gain is higher than the alarm threshold of the Pre-Amp Module <Help> This alarm indicates if the Pre-Amp g…
1.3.6.1.4.1.20044.61.2.2.2.32.3ScalarpmoabphcsAlmClientInputPwrLowAlarmread-onlycurrentPre-Amp Rx Pwr Low Alarm :This OID indicates that the Receive Power is lower than the alarm threshold of the Pre-Amp Optical Module <Help> This alarm indicates…
1.3.6.1.4.1.20044.61.2.2.2.32.4ScalarpmoabphcsAlmClientInputPwrHighAlarmread-onlycurrentPre-Amp Rx Pwr High Alarm :This OID indicates that the Receive Power is higher than the alarm threshold of the Pre-Amp Optical Module <Help> This alarm indicat…
1.3.6.1.4.1.20044.61.2.2.2.32.5ScalarpmoabphcsAlmClientOutputPwrLowAlarmread-onlycurrentPre-Amp Tx Pwr Low Alarm :This OID indicates that the Transmit Power is lower than the alarm threshold of the Pre-Amp Optical Module <Help> This alarm indicate…
1.3.6.1.4.1.20044.61.2.2.2.32.6ScalarpmoabphcsAlmClientOutputPwrHighAlarmread-onlycurrentPre-Amp Tx Pwr High Alarm :This OID indicates that the Transmit Power is higher than the alarm threshold of the Pre-Amp Optical Module <Help> This alarm indica…
1.3.6.1.4.1.20044.61.2.2.2.32.7ScalarpmoabphcsAlmClientBiasLowAlarmread-onlycurrentPre-Amp Bias Low Alarm :This OID indicates that the Bias is lower than the alarm threshold of the Pre-Amp Optical Module <Help> This alarm indicates if the Pre…
1.3.6.1.4.1.20044.61.2.2.2.32.8ScalarpmoabphcsAlmClientBiasHighAlarmread-onlycurrentPre-Amp Bias High Alarm :This OID indicates that the Bias is higher than the alarm threshold of the Pre-Amp Optical Module <Help> This alarm indicates if the P…
1.3.6.1.4.1.20044.61.2.2.3NodepmoabphcsAlmClientCrit
1.3.6.1.4.1.20044.61.2.2.3.8NodepmoabphcsAlmsynthAlm8
1.3.6.1.4.1.20044.61.2.2.3.8.4ScalarpmoabphcsAlmClientHwFailread-onlycurrentClient Port HW Failure :This OID indicates a failure on Client port, most probably caused by a HW issue <Condtype> CLIENT_HW_FAIL <Probcause> equipmentMalfunct…
1.3.6.1.4.1.20044.61.2.2.3.8.5ScalarpmoabphcsAlmClientTxOffread-onlycurrentPre-Amp Optical Output Shutdown :This OID indicates the Pre-Amp optical output power is on <Help> This status indicates if the Pre-Amp laser pump transceiver l…
1.3.6.1.4.1.20044.61.2.2.3.8.12ScalarpmoabphcsAlmClientFailread-onlycurrentClient Port Failure :This OID indicates a failure on the Client port <Condtype> CLIENT_FAIL <Probcause> bandwidthReduced(4) <Alarmtype> synthesisAlarm (12) <Po…
1.3.6.1.4.1.20044.61.2.2.3.8.13ScalarpmoabphcsAlmClientExtPumpFailread-onlycurrentPre-Amp External Pump Fail :This OID indicates that the external pump linked to the Pre-Amp is in fail condition <Help> This alarm indicates if the external pu…
1.3.6.1.4.1.20044.61.2.2.3.8.14ScalarpmoabphcsAlmSupvbFailread-onlycurrent: <Condtype> SUPVB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> equipmentAlarm (5) <Polarity> (2)
1.3.6.1.4.1.20044.61.2.2.3.35NodepmoabphcsAlmclientEdfaAlarms2
1.3.6.1.4.1.20044.61.2.2.3.35.1ScalarpmoabphcsAlmClientEdfaNrread-onlycurrentPre-Amp Optical Module Not Ready :This OID indicates that the Pre-Amp Optical Module is not ready <Help> This status indicates if the Pre-Amp has been correctl…
1.3.6.1.4.1.20044.61.2.2.3.35.2ScalarpmoabphcsAlmClientEdfaTecFailread-onlycurrentPre-Amp TEC Fail :This OID indicates that the TEC is in fail condition on the Pre-Amp Optical Module <Help> This alarm indicates if the TEC of the Pre-Amp is i…
1.3.6.1.4.1.20044.61.2.2.3.35.3ScalarpmoabphcsAlmClientEdfaLaserFailread-onlycurrentPre-Amp Pump Laser Fail :This OID indicates a Transmit Laser Fail on the Pre-Amp Optical Module <Help> This alarm indicates if the laser of the Pre-Amp is in f…
1.3.6.1.4.1.20044.61.2.2.3.35.4ScalarpmoabphcsAlmClientEdfaLosread-onlycurrentPre-Amp Loss Of Signal :This OID indicates a Loss of Signal on the Pre-Amp Optical Module <Help> This alarm indicates if an optical signal is detected on the P…
1.3.6.1.4.1.20044.61.2.2.3.35.5ScalarpmoabphcsAlmClientExtPumpEdfaLowCurrentread-onlycurrentPre-Amp Pump Low Current :This OID indicates that the EDFA pump current of Pre-Amp is too low because of the external pump high power<Help> This alarm (only ac…
1.3.6.1.4.1.20044.61.2.2.3.35.6ScalarpmoabphcsAlmClientGainOutOfRangeread-onlycurrentPre-Amp Gain Out Of Range :This OID indicates the target gain of the Pre-Amp is out of range (18-32dB), the flatness of the Booster is not guaranteed.<Help> Th…
1.3.6.1.4.1.20044.61.2.2.3.37NodepmoabphcsAlmclientMsaAlarms
1.3.6.1.4.1.20044.61.2.2.3.37.1ScalarpmoabphcsAlmClientMsaLosread-onlycurrentPre-Amp MSA Loss Of Signal :This OID indicates a Loss of Signal is detected on the Mid Stage Access of the Pre-Amp EDFAThis alarm indicates a Loss of Signal is…
1.3.6.1.4.1.20044.61.2.2.3.37.2ScalarpmoabphcsAlmClientMsaAttenuationread-onlycurrentPre-Amp MSA Attenuation Alarm :This OID indicates the attenuation on the Pre-Amp Mid Stage access has changed.This alarm indicates the attenuation on the Pre-A…
1.3.6.1.4.1.20044.61.2.3NodepmoabphcsAlmLine
1.3.6.1.4.1.20044.61.2.3.1NodepmoabphcsAlmLineNurg
1.3.6.1.4.1.20044.61.2.3.1.41NodepmoabphcsAlmlineEdfaWarnings
1.3.6.1.4.1.20044.61.2.3.1.41.1ScalarpmoabphcsAlmLineGainLowWarningread-onlycurrentBooster Gain Low Warning :This OID indicates that the Gain is lower than the Warning threshold of the Booster Module <Help> This alarm indicates if the Booster…
1.3.6.1.4.1.20044.61.2.3.1.41.2ScalarpmoabphcsAlmLineGainHighWarningread-onlycurrentBooster Gain High Warning :This OID indicates that the Gain is higher than the Warning threshold of the Booster Module <Help> This alarm indicates if the Boost…
1.3.6.1.4.1.20044.61.2.3.1.41.3ScalarpmoabphcsAlmLineInputPwrLowWarningread-onlycurrentBooster Rx Pwr Low Warning :This OID indicates that the Receive Power is lower than the Warning threshold of the Booster Optical Module <Help> This warning ind…
1.3.6.1.4.1.20044.61.2.3.1.41.4ScalarpmoabphcsAlmLineInputPwrHighWarningread-onlycurrentBooster Rx Pwr High Warning :This OID indicates that the Receive Power is higher than the Warning threshold of the Booster Optical Module <Help> This warning i…
1.3.6.1.4.1.20044.61.2.3.1.41.5ScalarpmoabphcsAlmLineOutputPwrLowWarningread-onlycurrentBooster Tx Pwr Low Warning :This OID indicates that the Transmit Power is lower than the Warning threshold of the Booster Optical Module <Help> This warning in…
1.3.6.1.4.1.20044.61.2.3.1.41.6ScalarpmoabphcsAlmLineOutputPwrHighWarningread-onlycurrentBooster Tx Pwr High Warning :This OID indicates that the Transmit Power is higher than the Warning threshold of the Booster Optical Module <Help> This warning …
1.3.6.1.4.1.20044.61.2.3.1.41.7ScalarpmoabphcsAlmLineBiasLowWarningread-onlycurrentBooster Bias Low Warning :This OID indicates that the Bias is lower than the Warning threshold of the Booster Optical Module <Help> This warning indicates if t…
1.3.6.1.4.1.20044.61.2.3.1.41.8ScalarpmoabphcsAlmLineBiasHighWarningread-onlycurrentBooster Bias High Warning :This OID indicates that the Bias is higher than the Warning threshold of the Booster Optical Module <Help> This warning indicates if…
1.3.6.1.4.1.20044.61.2.3.2NodepmoabphcsAlmLineUrg
1.3.6.1.4.1.20044.61.2.3.2.40NodepmoabphcsAlmlineEdfaAlarms1
1.3.6.1.4.1.20044.61.2.3.2.40.1ScalarpmoabphcsAlmLineGainLowAlarmread-onlycurrentBooster Gain Low Alarm :This OID indicates that the Gain is lower than the alarm threshold of the Booster Module <Help> This alarm indicates if the Booster gai…
1.3.6.1.4.1.20044.61.2.3.2.40.2ScalarpmoabphcsAlmLineGainHighAlarmread-onlycurrentBooster Gain High Alarm :This OID indicates that the Gain is higher than the alarm threshold of the Booster Module <Help> This alarm indicates if the Booster g…
1.3.6.1.4.1.20044.61.2.3.2.40.3ScalarpmoabphcsAlmLineInputPwrLowAlarmread-onlycurrentBooster Rx Pwr Low Alarm :This OID indicates that the Receive Power is lower than the alarm threshold of the Booster Optical Module <Help> This alarm indicates…
1.3.6.1.4.1.20044.61.2.3.2.40.4ScalarpmoabphcsAlmLineInputPwrHighAlarmread-onlycurrentBooster Rx Pwr High Alarm :This OID indicates that the Receive Power is higher than the alarm threshold of the Booster Optical Module <Help> This alarm indicat…
1.3.6.1.4.1.20044.61.2.3.2.40.5ScalarpmoabphcsAlmLineOutputPwrLowAlarmread-onlycurrentBooster Tx Pwr Low Alarm :This OID indicates that the Transmit Power is lower than the alarm threshold of the Booster Optical Module <Help> This alarm indicate…
1.3.6.1.4.1.20044.61.2.3.2.40.6ScalarpmoabphcsAlmLineOutputPwrHighAlarmread-onlycurrentBooster Tx Pwr High Alarm :This OID indicates that the Transmit Power is higher than the alarm threshold of the Booster Optical Module <Help> This alarm indica…
1.3.6.1.4.1.20044.61.2.3.2.40.7ScalarpmoabphcsAlmLineBiasLowAlarmread-onlycurrentBooster Bias Low Alarm :This OID indicates that the Bias is lower than the alarm threshold of the Booster Optical Module <Help> This alarm indicates if the Boo…
1.3.6.1.4.1.20044.61.2.3.2.40.8ScalarpmoabphcsAlmLineBiasHighAlarmread-onlycurrentBooster Bias High Alarm :This OID indicates that the Bias is higher than the alarm threshold of the Booster Optical Module <Help> This alarm indicates if the B…
1.3.6.1.4.1.20044.61.2.3.3NodepmoabphcsAlmLineCrit
1.3.6.1.4.1.20044.61.2.3.3.7NodepmoabphcsAlmsynthAlm7
1.3.6.1.4.1.20044.61.2.3.3.7.4ScalarpmoabphcsAlmLineHwFailread-onlycurrentLine Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Condtype> LINE_HW_FAIL <Probcause> equipmentMalfunction (1…
1.3.6.1.4.1.20044.61.2.3.3.7.5ScalarpmoabphcsAlmLineTxOffread-onlycurrentBooster Optical Output Shutdown :This OID indicates the Booster optical output power is on <Help> This status indicates if the Booster laser pump is ON or OFF …
1.3.6.1.4.1.20044.61.2.3.3.7.12ScalarpmoabphcsAlmLineFailread-onlycurrentLine Port Failure :This OID indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> callEstablishmentError(5) <Alarmtype> synthesisAlarm (12) <Po…
1.3.6.1.4.1.20044.61.2.3.3.7.13ScalarpmoabphcsAlmLineExtPumpFailread-onlycurrentBooster External Pump Fail :This OID indicates that the external pump linked to the Booster is in fail condition <Help> This alarm indicates if the external pu…
1.3.6.1.4.1.20044.61.2.3.3.7.14ScalarpmoabphcsAlmSupvaFailread-onlycurrent: <Condtype> SUPVA_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> equipmentAlarm (5) <Polarity> (2)
1.3.6.1.4.1.20044.61.2.3.3.43NodepmoabphcsAlmlineEdfaAlarms2
1.3.6.1.4.1.20044.61.2.3.3.43.1ScalarpmoabphcsAlmLineEdfaNrread-onlycurrentBooster Optical Module Not Ready :This OID indicates that the Booster Optical Module is not ready <Help> This status indicates if the Booster has been correctl…
1.3.6.1.4.1.20044.61.2.3.3.43.2ScalarpmoabphcsAlmLineEdfaTecFailread-onlycurrentBooster TEC Fail :This OID indicates that the TEC is in fail condition on the Booster Optical Module <Help> This alarm indicates if the TEC of the Booster is i…
1.3.6.1.4.1.20044.61.2.3.3.43.3ScalarpmoabphcsAlmLineEdfaLaserFailread-onlycurrentBooster Pump Laser Fail :This OID indicates a Transmit Laser Fail on the Booster Optical Module <Help> This alarm indicates if the laser of the Booster is in f…
1.3.6.1.4.1.20044.61.2.3.3.43.4ScalarpmoabphcsAlmLineEdfaLosread-onlycurrentBooster Loss Of Signal :This OID indicates a Loss of Signal on the Booster Optical Module <Help> This alarm indicates if an optical signal is detected on the B…
1.3.6.1.4.1.20044.61.2.3.3.43.5ScalarpmoabphcsAlmLineExtPumpEdfaLowCurrentread-onlycurrentBooster Pump Low Current :This OID indicates that the EDFA pump current of Booster is too low because of the external pump high power<Help> This alarm (only ac…
1.3.6.1.4.1.20044.61.2.3.3.43.6ScalarpmoabphcsAlmLineGainOutOfRangeread-onlycurrentBooster Gain Out Of Range :This OID indicates the target gain of the Booster is out of range (10-18dB), the flatness of the Booster is not guaranteed.<Help> Th…
1.3.6.1.4.1.20044.61.2.3.3.45NodepmoabphcsAlmlineMsaAlarms
1.3.6.1.4.1.20044.61.2.3.3.45.1ScalarpmoabphcsAlmLineMsaLosread-onlycurrentBooster MSA Loss Of Signal :This OID indicates a Loss of Signal is detected on the Mid Stage Access of the Booster EDFAThis alarm indicates a Loss of Signal is…
1.3.6.1.4.1.20044.61.2.3.3.45.2ScalarpmoabphcsAlmLineMsaAttenuationread-onlycurrentBooster MSA Attenuation Alarm :This OID indicates the attenuation on the Booster Mid Stage access has changed.This alarm indicates the attenuation on the Pre-A…
1.3.6.1.4.1.20044.61.2.3.3.48TablepmoabphcsAlmlineOscAlarmsTablenot-accessiblecurrentList of pmoabphcsAlmlineOscAlarms Article
1.3.6.1.4.1.20044.61.2.3.3.48.1RowpmoabphcsAlmlineOscAlarmsEntrynot-accessiblecurrentRow definition for the pmoabphcsAlmlineOscAlarms table
1.3.6.1.4.1.20044.61.2.3.3.48.1.1ColumnpmoabphcsAlmlineOscAlarmsIndexread-onlycurrentIndex definition for the pmoabphcsAlmlineOscAlarms table
1.3.6.1.4.1.20044.61.2.3.3.48.1.2ColumnpmoabphcsAlmLineLosPortnread-onlycurrentOSC Loss Of Signal :This OID indicates that no signal is present on the OSC <Help> This alarms indicates that no signal is present on the OSC <Condtype> LINE_L…
1.3.6.1.4.1.20044.61.2.3.3.48.1.3ColumnpmoabphcsAlmLineTxOffPortnread-onlycurrentOSC Optical Output Shutdown :This OID indicates the optical output power is shutdown on OSC<Help> This alarm indicates the optical output power is shutdown on …
1.3.6.1.4.1.20044.61.2.3.3.48.1.4ColumnpmoabphcsAlmLineTxFailPortnread-onlycurrentOSC Tx Fail :This OID indicates the OSC Laser is in fail condition<Help> This alarm indicates the OSC Laser is in fail condition <Condtype> LINE_TX_FAIL_1 <Pro…
1.3.6.1.4.1.20044.61.2.3.3.48.1.5ColumnpmoabphcsAlmLineFecFailPortnread-onlycurrentOSC FEC Fail :This OID indicates the FEC is in fail condition on the OSC input port<Help> This alarms indicates the FEC is in fail condition on the OSC input p…
1.3.6.1.4.1.20044.61.2.3.3.48.1.6ColumnpmoabphcsAlmLineOosPortnread-onlycurrentOSC In Service :This OID indicates that the OSC is In Service (1) or Out or Service (2)<Help> This status indicates that the OSC is In Service or Out or Servic…
1.3.6.1.4.1.20044.61.2.3.3.48.1.7ColumnpmoabphcsAlmLineLofPortnread-onlycurrentOSC Loss Of Frame : <Condtype> LINE_LOF_1 <Probcause> inputOutputDeviceError(24) <Alarmtype> equipmentAlarm (5) <Polarity> (2)
1.3.6.1.4.1.20044.61.2.3.3.48.1.8ColumnpmoabphcsAlmLineOofPortnread-onlycurrentOSC Out Of Frame : <Condtype> LINE_OOF_1 <Probcause> inputOutputDeviceError(24) <Alarmtype> equipmentAlarm (5) <Polarity> (2)
1.3.6.1.4.1.20044.61.2.3.3.48.1.9ColumnpmoabphcsAlmLineRemoteTxFailPortnread-onlycurrentOSC Remote Tx Fail : <Condtype> LINE_REMOTE_TX_FAIL_1 <Probcause> informationalStatus(1000) <Alarmtype> other(1) <Polarity> (2)
1.3.6.1.4.1.20044.61.2.3.3.48.1.10ColumnpmoabphcsAlmLineWarningPortnread-onlycurrentOSC DDM Warning :This OID indicates a warning is present on OSC Tx power, Receive power or temperature<Help> This alarm indicates a warning is present on OSC T…
1.3.6.1.4.1.20044.61.2.3.3.48.1.11ColumnpmoabphcsAlmLineAlmPortnread-onlycurrentOSC DDM Alarm :This alarm indicates an alarm is present on OSC Tx power, Rx power or temperature <Help> This alarm indicates an alarm is present on OSC Tx powe…
1.3.6.1.4.1.20044.61.2.3.3.49TablepmoabphcsAlmlineOscThresholdAlarmsTablenot-accessiblecurrentList of pmoabphcsAlmlineOscThresholdAlarms Article
1.3.6.1.4.1.20044.61.2.3.3.49.1RowpmoabphcsAlmlineOscThresholdAlarmsEntrynot-accessiblecurrentRow definition for the pmoabphcsAlmlineOscThresholdAlarms table
1.3.6.1.4.1.20044.61.2.3.3.49.1.1ColumnpmoabphcsAlmlineOscThresholdAlarmsIndexread-onlycurrentIndex definition for the pmoabphcsAlmlineOscThresholdAlarms table
1.3.6.1.4.1.20044.61.2.3.3.49.1.2ColumnpmoabphcsAlmLineTxPwrLowAlarmPortnread-onlycurrentOSC Tx Power Low Alarm :This OID indicates the Tx Power of the OSC is lower than the warning threshold<Help> This alarm indicates the Tx Power of the OSC is lo…
1.3.6.1.4.1.20044.61.2.3.3.49.1.3ColumnpmoabphcsAlmLineTxPwrHighAlarmPortnread-onlycurrentOSC Tx Power High Alarm :This OID indicates the Tx Power of the OSC is higher than the warning threshold<Help> This alarm indicates the Tx Power of the OSC is …
1.3.6.1.4.1.20044.61.2.3.3.49.1.4ColumnpmoabphcsAlmLineRxPwrLowAlarmPortnread-onlycurrentOSC Rx Power Low Alarm :This OID indicates the Rx Power of the OSC is lower than the alarm threshold<Help> This alarm indicates the Rx Power of the OSC is lowe…
1.3.6.1.4.1.20044.61.2.3.3.49.1.5ColumnpmoabphcsAlmLineRxPwrHighAlarmPortnread-onlycurrentOSC Rx Power High Alarm :This OID indicates the Rx Power of the OSC is higher than the alarm threshold<Help> This alarm indicates the Rx Power of the OSC is hi…
1.3.6.1.4.1.20044.61.2.3.3.49.1.6ColumnpmoabphcsAlmLineSpanlossLowAlarmPortnread-onlycurrentOSC Span Loss Low Alarm :This OID indicates the OSC Span Loss is 3dB lower than the span loss reference<Help> This alarm indicates the OSC Span Loss is 3dB low…
1.3.6.1.4.1.20044.61.2.3.3.49.1.7ColumnpmoabphcsAlmLineSpanlossHighAlarmPortnread-onlycurrentOSC Span Loss High Alarm :This OID indicates the OSC Span Loss is 3dB higher than the span loss reference <Help> This alarm indicates the OSC Span Loss is 3dB …
1.3.6.1.4.1.20044.61.2.3.3.49.1.8ColumnpmoabphcsAlmLineOscBiasLowAlarmPortnread-onlycurrentOSC Bias Current Low Alarm :This OID indicates the OSC bias current is lower than the alarm threshold <Help> This alarm indicates the OSC bias current is lower…
1.3.6.1.4.1.20044.61.2.3.3.49.1.9ColumnpmoabphcsAlmLineOscBiasHighAlarmPortnread-onlycurrentOSC Bias Current High Alarm :This OID indicates the OSC bias current is higher than the alarm threshold <Help> This alarm indicates the OSC bias current is hig…
1.3.6.1.4.1.20044.61.2.3.3.50TablepmoabphcsAlmlineOscThresholdsWarningsTablenot-accessiblecurrentList of pmoabphcsAlmlineOscThresholdsWarnings Article
1.3.6.1.4.1.20044.61.2.3.3.50.1RowpmoabphcsAlmlineOscThresholdsWarningsEntrynot-accessiblecurrentRow definition for the pmoabphcsAlmlineOscThresholdsWarnings table
1.3.6.1.4.1.20044.61.2.3.3.50.1.1ColumnpmoabphcsAlmlineOscThresholdsWarningsIndexread-onlycurrentIndex definition for the pmoabphcsAlmlineOscThresholdsWarnings table
1.3.6.1.4.1.20044.61.2.3.3.50.1.2ColumnpmoabphcsAlmLineTxPwrLowWarningPortnread-onlycurrentOSC Tx Power Low Warning :This OID indicates the Tx Power of the OSC is lower than the warning threshold<Help> This alarm indicates the Tx Power of the OSC is …
1.3.6.1.4.1.20044.61.2.3.3.50.1.3ColumnpmoabphcsAlmLineTxPwrHighWarningPortnread-onlycurrentOSC Tx Power High Warning :This OID indicates the Tx Power of the OSC is higher than the warning threshold<Help> This alarm indicates the Tx Power of the OSB i…
1.3.6.1.4.1.20044.61.2.3.3.50.1.4ColumnpmoabphcsAlmLineRxPwrLowWarningPortnread-onlycurrentOSC Rx Power Low Warning :This OID indicates the Rx Power of the OSC is lower than the warning threshold<Help> This alarm indicates the Tx Power of the OSC is …
1.3.6.1.4.1.20044.61.2.3.3.50.1.5ColumnpmoabphcsAlmLineRxPwrHighWarningPortnread-onlycurrentOSC Rx Power High Warning :This OID indicates the Rx Power of the OSC is higher than the warning threshold<Help> This alarm indicates the Rx Power of the OSC i…
1.3.6.1.4.1.20044.61.2.3.3.50.1.6ColumnpmoabphcsAlmLineSpanlossLowWarningPortnread-onlycurrentOSC Span Loss Low Warning :This OID indicates the OSC Span Loss is 1dB lower than the span loss reference<Help> This alarm indicates the OSC Span Loss is 1dB l…
1.3.6.1.4.1.20044.61.2.3.3.50.1.7ColumnpmoabphcsAlmLineSpanlossHighWarningPortnread-onlycurrentOSC Span Loss High Warning :This OID indicates the OSC Span Loss is 1dB higher than the span loss reference <Help> This alarm indicates the OSC Span Loss is 1d…
1.3.6.1.4.1.20044.61.2.3.3.50.1.8ColumnpmoabphcsAlmLineOscBiasLowWarningPortnread-onlycurrentOSC Bias Current Low Warning :This OID indicates the OSC bias current is lower than the warning threshold <Help> This alarm indicates the OSC bias current is l…
1.3.6.1.4.1.20044.61.2.3.3.50.1.9ColumnpmoabphcsAlmLineOscBiasHighWarningPortnread-onlycurrentOSC Bias Current High Warning :This OID indicates the OSC bias current is higher than the warning threshold <Help> This alarm indicates the OSC bias current is…
1.3.6.1.4.1.20044.61.3Nodepmoabphcsmeasures
1.3.6.1.4.1.20044.61.3.1NodepmoabphcsMesrOther
1.3.6.1.4.1.20044.61.3.1.80ScalarpmoabphcsMesrtempMeasread-onlycurrentModule Temperature :This OID gives the temperature of the PM (Temperature =AV/256) (Unit = C) <Help> This measure gives the temperature of the module
1.3.6.1.4.1.20044.61.3.2NodepmoabphcsMesrClient
1.3.6.1.4.1.20044.61.3.2.32ScalarpmoabphcsMesrclientEdfaBiasMeasread-onlycurrentPre-Amp Pump Laser Current :This OID gives the pump laser current of the Pre-Amp Optical Module (Current =AV/100) (Unit = mA) <Help> This measure gives the bia…
1.3.6.1.4.1.20044.61.3.2.33ScalarpmoabphcsMesrclientEdfaTxpwrMeasread-onlycurrentPre-Amp Tx Power :This OID gives the transmit power value of the Pre-Amp Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Tx…
1.3.6.1.4.1.20044.61.3.2.34ScalarpmoabphcsMesrclientEdfaRxpwrMeasread-onlycurrentPre-Amp Rx Power :This OID gives the receive power value of the Pre-Amp Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Rx …
1.3.6.1.4.1.20044.61.3.2.35ScalarpmoabphcsMesrclientEdfaGainMeasread-onlycurrentPre-Amp Gain Target :This OID gives the gain value of the Pre-Amp Module (Gain =(AV-32768)*0,005) (Unit = dB) <Help> This information gives the target gain of …
1.3.6.1.4.1.20044.61.3.2.36ScalarpmoabphcsMesrclientOscSpanLossread-onlycurrentPre-Amp Input Span Loss :This OID indicates the attenuation of the span connected to the Pre-amp input (Power =(AV-32768)*0,005) (Unit = dB) <Help> This measur…
1.3.6.1.4.1.20044.61.3.2.37ScalarpmoabphcsMesrclientOscSpanLossRefread-onlycurrentPre-Amp Input Span Loss Ref :This OID indicates the referenced attenuation of the span connected to the Pre-amp input (Used to monitor the variation of the spa…
1.3.6.1.4.1.20044.61.3.2.38ScalarpmoabphcsMesrclientCorrectedGainread-onlycurrentPre-Amp Gain :This OID gives the gain value of the Pre-Amp Module corrected by the ASE compensation mechanism (Gain =(AV-32768)*0,005) (Unit = dB) <Help> This …
1.3.6.1.4.1.20044.61.3.2.39ScalarpmoabphcsMesrclientMsaInputPowerread-onlycurrentPre-Amp MSA Rx Power :This OID indicates the input power of the Mid Stage Access of the Pre-Amp (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure indi…
1.3.6.1.4.1.20044.61.3.2.40ScalarpmoabphcsMesrclientMsaOutputPowerread-onlycurrentPre-Amp MSA Tx Power :This OID indicates the output power of the Mid Stage Access of the Pre-Amp (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure ind…
1.3.6.1.4.1.20044.61.3.2.41ScalarpmoabphcsMesrclientMsaAttenuationread-onlycurrentPre-Amp MSA Attenuation :This OID indicates the attenuation applied on the Mid Stage Access of the Pre-Amp (Attenuation =(AV-32768)*0,005) (Unit = dB) <Help> T…
1.3.6.1.4.1.20044.61.3.2.42ScalarpmoabphcsMesrclientMsaAttenuationRefread-onlycurrentPre-Amp MSA Attenuation Ref :This OID indicates the reference attenuation stored for the Mid Stage Access of the In-Line1 (Used to monitor the variation of thi…
1.3.6.1.4.1.20044.61.3.3NodepmoabphcsMesrLine
1.3.6.1.4.1.20044.61.3.3.48ScalarpmoabphcsMesrlineEdfaBiasMeasread-onlycurrentBooster Pump Laser Current :This OID gives the pump laser current of the Booster Optical Module (Current =AV/100) (Unit = mA) <Help> This measure gives the bia…
1.3.6.1.4.1.20044.61.3.3.49ScalarpmoabphcsMesrlineEdfaTxpwrMeasread-onlycurrentBooster Tx Power :This OID gives the transmit power value of the Booster Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Tx…
1.3.6.1.4.1.20044.61.3.3.50ScalarpmoabphcsMesrlineEdfaRxpwrMeasread-onlycurrentBooster Rx Power :This OID gives the receive power value of the Booster Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Rx …
1.3.6.1.4.1.20044.61.3.3.51ScalarpmoabphcsMesrlineEdfaGainMeasread-onlycurrentBooster Gain Target :This OID gives the gain value of the Booster Module (Gain =(AV-32768)*0,005) (Unit = dB) <Help> This information gives the target gain of …
1.3.6.1.4.1.20044.61.3.3.52ScalarpmoabphcsMesrlineOscSpanLossread-onlycurrentBooster Input Span Loss :This OID indicates the attenuation of the span connected to the Booster input (Power =(AV-32768)*0,005) (Unit = dB) <Help> This measur…
1.3.6.1.4.1.20044.61.3.3.53ScalarpmoabphcsMesrlineOscSpanLossRefread-onlycurrentBooster Input Span Loss Ref :This OID indicates the referenced attenuation of the span connected to the Booster input (Used to monitor the variation of the spa…
1.3.6.1.4.1.20044.61.3.3.54ScalarpmoabphcsMesrlineCorrectedGainread-onlycurrentBooster Gain :This OID gives the gain value of the Booster Module corrected by the ASE compensation mechanism (Gain =(AV-32768)*0,005) (Unit = dB) <Help> This …
1.3.6.1.4.1.20044.61.3.3.55ScalarpmoabphcsMesrlineMsaInputPowerread-onlycurrentBooster MSA Rx Power :This OID indicates the input power of the Mid Stage Access of the Booster (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure indi…
1.3.6.1.4.1.20044.61.3.3.56ScalarpmoabphcsMesrlineMsaOutputPowerread-onlycurrentBooster MSA Tx Power :This OID indicates the output power of the Mid Stage Access of the Booster (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure ind…
1.3.6.1.4.1.20044.61.3.3.57ScalarpmoabphcsMesrlineMsaAttenuationread-onlycurrentBooster MSA Attenuation :This OID indicates the attenuation applied on the Mid Stage Access of the Booster (Attenuation =(AV-32768)*0,005) (Unit = dB) <Help> T…
1.3.6.1.4.1.20044.61.3.3.58ScalarpmoabphcsMesrlineMsaAttenuationRefread-onlycurrentBooster MSA Attenuation Ref :This OID indicates the reference attenuation stored for the Mid Stage Access of the Booster (Used to monitor the variation of this…
1.3.6.1.4.1.20044.61.3.3.64TablepmoabphcsMesrlineOscTxPowerTablenot-accessiblecurrentList of pmoabphcsMesrlineOscTxPower Article
1.3.6.1.4.1.20044.61.3.3.64.1RowpmoabphcsMesrlineOscTxPowerEntrynot-accessiblecurrentRow definition for the pmoabphcsMesrlineOscTxPower table
1.3.6.1.4.1.20044.61.3.3.64.1.1ColumnpmoabphcsMesrlineOscTxPowerIndexread-onlycurrentIndex definition for the pmoabphcsMesrlineOscTxPower table
1.3.6.1.4.1.20044.61.3.3.64.1.2ColumnpmoabphcsMesrlineOscTxPowerPortnread-onlycurrentOSC Tx Power :This OID indicates the output power of the OSC (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure indicates the output power of the OSC
1.3.6.1.4.1.20044.61.3.3.65TablepmoabphcsMesrlineOscRxPowerTablenot-accessiblecurrentList of pmoabphcsMesrlineOscRxPower Article
1.3.6.1.4.1.20044.61.3.3.65.1RowpmoabphcsMesrlineOscRxPowerEntrynot-accessiblecurrentRow definition for the pmoabphcsMesrlineOscRxPower table
1.3.6.1.4.1.20044.61.3.3.65.1.1ColumnpmoabphcsMesrlineOscRxPowerIndexread-onlycurrentIndex definition for the pmoabphcsMesrlineOscRxPower table
1.3.6.1.4.1.20044.61.3.3.65.1.2ColumnpmoabphcsMesrlineOscRxPowerPortnread-onlycurrentOSC Rx Power :This OID indicates the input power of the OSC (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure indicates the input power of the OSC
1.3.6.1.4.1.20044.61.4Nodepmoabphcscounters
1.3.6.1.4.1.20044.61.4.1NodepmoabphcsCntOther
1.3.6.1.4.1.20044.61.4.2NodepmoabphcsCntClient
1.3.6.1.4.1.20044.61.4.3NodepmoabphcsCntLine
1.3.6.1.4.1.20044.61.4.3.16TablepmoabphcsCntlineOscErrTablenot-accessiblecurrentList of pmoabphcsCntlineOscErr Article
1.3.6.1.4.1.20044.61.4.3.16.1RowpmoabphcsCntlineOscErrEntrynot-accessiblecurrentRow definition for the pmoabphcsCntlineOscErr table
1.3.6.1.4.1.20044.61.4.3.16.1.1ColumnpmoabphcsCntlineOscErrIndexread-onlycurrentIndex definition for the pmoabphcsCntlineOscErr table
1.3.6.1.4.1.20044.61.4.3.16.1.2ColumnpmoabphcsCntlineOscErrValuePortnread-onlycurrentOSC FEC Counter :This OID indicates the number of errors corrected by the FEC of the OSC<Help> This measure indicates the number of errors corrected by the FEC…
1.3.6.1.4.1.20044.61.4.3.16.1.3ColumnpmoabphcsCntlineOscErrErrorPortnread-onlycurrentB1 Counter Error :This OID when set indicates the B1 counter value is invalid on Port
1.3.6.1.4.1.20044.61.4.3.16.1.4ColumnpmoabphcsCntlineOscErrOverloadPortnread-onlycurrentB1 Counter Overload :This OID when set indicates a B1 error counter overload on Port
1.3.6.1.4.1.20044.61.4.259ScalarpmoabphcsCntCountersResetread-writecurrentCounters Reset:This OID resets and restarts all the counters
1.3.6.1.4.1.20044.61.4.260ScalarpmoabphcsCntCountersStopread-writecurrentCounters stop:This OID stops all the counters
1.3.6.1.4.1.20044.61.6NodepmoabphcscontrolsWrite
1.3.6.1.4.1.20044.61.6.1NodepmoabphcsCtrlOther
1.3.6.1.4.1.20044.61.6.1.0NodepmoabphcsCtrlsynth0
1.3.6.1.4.1.20044.61.6.1.0.1ScalarpmoabphcsCtrlConfLoadread-writecurrentLoad Configuration Tables :When set this enables loading from flash configuration1 into the module.
1.3.6.1.4.1.20044.61.6.1.0.9ScalarpmoabphcsCtrlConfFlashread-writecurrentWrite Configuration Tables :This bit saves the current configuration of the module as configuration in the flash. <Help> This control saves the customer config…
1.3.6.1.4.1.20044.61.6.1.0.13ScalarpmoabphcsCtrlConfClearread-writecurrentClear Configuration Tables :This bit clears the configuration tables from configuration in the flash. <Help> This control restores the default configuration of…
1.3.6.1.4.1.20044.61.6.1.5NodepmoabphcsCtrlswMgnt
1.3.6.1.4.1.20044.61.6.1.5.2ScalarpmoabphcsCtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the Software. This reset is traffic affecting, and the configuration of Software is reloaded on start…
1.3.6.1.4.1.20044.61.6.1.5.3ScalarpmoabphcsCtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the Software. This reset is not traffic affecting, and the configuration of the Sofwtare remains unch…
1.3.6.1.4.1.20044.61.6.1.73NodepmoabphcsCtrlledTest
1.3.6.1.4.1.20044.61.6.1.73.1ScalarpmoabphcsCtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.61.6.1.73.2ScalarpmoabphcsCtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.61.6.1.73.3ScalarpmoabphcsCtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.61.6.1.75NodepmoabphcsCtrlmaintMode
1.3.6.1.4.1.20044.61.6.1.75.1ScalarpmoabphcsCtrlMaintenanceread-writecurrentPM Maintenance Mode :This OID sets the PM in maintenance mode <Help> This control enables the maintenance mode of the module
1.3.6.1.4.1.20044.61.6.1.76NodepmoabphcsCtrlaprRestart
1.3.6.1.4.1.20044.61.6.1.76.1ScalarpmoabphcsCtrlAprManualRestartread-writecurrentAPR Manual Restart :This OID initiates the Restart mechanism to retrieve from the APR state.<Help> This control initiates the Restart mechanism to retrieve fro…
1.3.6.1.4.1.20044.61.6.2NodepmoabphcsCtrlClient
1.3.6.1.4.1.20044.61.6.2.33NodepmoabphcsCtrlclientOscInputSpanLoss
1.3.6.1.4.1.20044.61.6.2.33.1ScalarpmoabphcsCtrlClientSpanLossread-writecurrentStore Pre-Amp Input Span Loss :This OID stores the current input span Loss as a reference to monitor the span loss variation <Help> This parameter stores the c…
1.3.6.1.4.1.20044.61.6.2.34ScalarpmoabphcsCtrlclientGainCstMonitorValueread-writecurrentPre-Amp Fiber Aging Period :This OID sets the value of the monitoring period to detect a fiber aging. (Unit = s) This value sets the monitoring period to detec…
1.3.6.1.4.1.20044.61.6.2.36ScalarpmoabphcsCtrlclientGainSettingValueread-writecurrentPre-Amp Gain Target :This OID sets the value of the nominal gain of the Pre-Amplifier Module (active only in constant output power mode) (AV=(Gain/0,005) + 327…
1.3.6.1.4.1.20044.61.6.2.37NodepmoabphcsCtrlclientGainProcessing
1.3.6.1.4.1.20044.61.6.2.37.1ScalarpmoabphcsCtrlClientGainProcread-writecurrentPre-Amp Gain Adjustment :This OID initiates the automatic nominal gain adjustment on the Pre-Amplifier Module<Help> This control initiates the automatic nomina…
1.3.6.1.4.1.20044.61.6.2.38ScalarpmoabphcsCtrlclientGainCstFiberAgingMarginValueread-writecurrentPre-Amp Aging Threshold :This OID sets the threshold to consider the power drop as a fiber aging. (active only in constant gain mode) (AV=(Gain/0,005) + 32768)…
1.3.6.1.4.1.20044.61.6.2.40NodepmoabphcsCtrlclientMsaAttenuationValue
1.3.6.1.4.1.20044.61.6.2.40.1ScalarpmoabphcsCtrlClientAttenuationread-writecurrentStore Pre-Amp MSA Attenuation :This OID stores the current attenuation applied on the Mid Stage Access of the Pre-Amp (used for monitoring the MSA attenuation …
1.3.6.1.4.1.20044.61.6.3NodepmoabphcsCtrlLine
1.3.6.1.4.1.20044.61.6.3.49NodepmoabphcsCtrllineOscInputSpanLoss
1.3.6.1.4.1.20044.61.6.3.49.1ScalarpmoabphcsCtrlLineSpanLossread-writecurrentStore Booster Input Span Loss :This OID stores the current input span Loss as a reference to monitor the span loss variation<Help> This parameter stores the cu…
1.3.6.1.4.1.20044.61.6.3.50ScalarpmoabphcsCtrllineGainCstMonitorValueread-writecurrentBooster Fiber Aging Period :This OID sets the value of the monitoring period to detect a fiber aging. (Unit = s) This value sets the monitoring period to detec…
1.3.6.1.4.1.20044.61.6.3.52ScalarpmoabphcsCtrllineGainSettingValueread-writecurrentBooster Gain Target :This OID sets the value of the nominal gain of the Booster Module (active only in constant output power mode) (AV=(Gain/0,005) + 32768) (U…
1.3.6.1.4.1.20044.61.6.3.53NodepmoabphcsCtrllineGainProcessing
1.3.6.1.4.1.20044.61.6.3.53.1ScalarpmoabphcsCtrlLineGainProcread-writecurrentBooster Gain Adjustment :This OID initiates the automatic nominal gain adjustment on the Booster Module<Help> This control initiates the automatic nominal gain…
1.3.6.1.4.1.20044.61.6.3.54ScalarpmoabphcsCtrllineGainCstFiberAgingMarginValueread-writecurrentBooster Aging Threshold :This OID sets the threshold to consider the power drop as a fiber aging. (active only in constant gain mode) (AV=(Gain/0,005) + 32768)…
1.3.6.1.4.1.20044.61.6.3.56NodepmoabphcsCtrllineMsaAttenuationValue
1.3.6.1.4.1.20044.61.6.3.56.1ScalarpmoabphcsCtrlLineAttenuationread-writecurrentStore Booster MSA Attenuation :This OID stores the current attenuation applied on the Mid Stage Access of the Booster (used for monitoring the MSA attenuation …
1.3.6.1.4.1.20044.61.7Nodepmoabphcsri
1.3.6.1.4.1.20044.61.7.2ScalarpmoabphcsRinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.61.7.3ScalarpmoabphcsRinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.61.7.4ScalarpmoabphcsRinvModulePlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.61.7.5ScalarpmoabphcsRinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.61.7.6ScalarpmoabphcsRinvGwPlatformread-onlycurrentGW platform description: This OID contains the description of the gateware platform.
1.3.6.1.4.1.20044.61.7.7TablepmoabphcsRinvBoosterTablenot-accessiblecurrentList of the Boosters on the selected module
1.3.6.1.4.1.20044.61.7.7.1RowpmoabphcsRinvBoosterEntrynot-accessiblecurrentRow definition for the Boosters table
1.3.6.1.4.1.20044.61.7.7.1.1ColumnpmoabphcsRinvBoosterIndexread-onlycurrentIndex for Booster table
1.3.6.1.4.1.20044.61.7.7.1.2ColumnpmoabphcsRinvBoosterread-onlycurrentInventory for the Booster: This OID contains the inventory for the Booster
1.3.6.1.4.1.20044.61.7.8TablepmoabphcsRinvPreAmpTablenot-accessiblecurrentList of the PreAmps on the selected module
1.3.6.1.4.1.20044.61.7.8.1RowpmoabphcsRinvPreAmpEntrynot-accessiblecurrentRow definition for the PreAmp table
1.3.6.1.4.1.20044.61.7.8.1.1ColumnpmoabphcsRinvPreAmpIndexread-onlycurrentIndex for PreAmp table
1.3.6.1.4.1.20044.61.7.8.1.2ColumnpmoabphcsRinvPreAmpread-onlycurrentInventory for the PreAmp: This OID contains the inventory for the PreAmp
1.3.6.1.4.1.20044.61.9NodepmoabphcsConfig
1.3.6.1.4.1.20044.61.9.1NodepmoabphcsCfgNoValue
1.3.6.1.4.1.20044.61.9.1.1NodepmoabphcstableclientStartup
1.3.6.1.4.1.20044.61.9.1.1.2ScalarpmoabphcsCfgclientEdfaLaserCtrlread-writecurrentDefault Settings on Client Laser :This OID configures the default initialisation settings on the client laser.
1.3.6.1.4.1.20044.61.9.1.1.3ScalarpmoabphcsCfgclientEdfaLaserModeread-writecurrentDefault Settings on Client mode :This OID configures the default mode on the client amplifier.
1.3.6.1.4.1.20044.61.9.1.1.4ScalarpmoabphcsCfgclientGainValueread-writecurrentDefault Settings on Client Gain :This OID configures the default gain on the client amplifier.
1.3.6.1.4.1.20044.61.9.1.1.5ScalarpmoabphcsCfgclientTiltValueread-writecurrentDefault Settings on Client Tilt :This OID configures the default tilt on the client amplifier.
1.3.6.1.4.1.20044.61.9.1.1.6ScalarpmoabphcsCfgclientMsaLossread-writecurrentDefault Settings on Client MSA :This OID configures the default MSA value on the client amplifier.
1.3.6.1.4.1.20044.61.9.1.1.7ScalarpmoabphcsCfgclientOutputPowerValueread-writecurrentDefault Settings on Client Output power :This OID configures the default Output power value on the client amplifier.
1.3.6.1.4.1.20044.61.9.1.1.8ScalarpmoabphcsCfgclientAseCompensationread-writecurrentDefault Settings on Client ASE :This OID configures the default ASE compensation value on the client amplifier.
1.3.6.1.4.1.20044.61.9.2NodepmoabphcsCfgLineStartUp
1.3.6.1.4.1.20044.61.9.2.1NodepmoabphcstablelineStartup
1.3.6.1.4.1.20044.61.9.2.1.2ScalarpmoabphcsCfglineEdfaLaserCtrlread-writecurrentDefault Settings on Line Laser :This OID configures the default initialisation settings on the line laser.
1.3.6.1.4.1.20044.61.9.2.1.3ScalarpmoabphcsCfglineEdfaLaserModeread-writecurrentDefault Settings on Line mode :This OID configures the default mode on the line amplifier.
1.3.6.1.4.1.20044.61.9.2.1.4ScalarpmoabphcsCfglineGainValueread-writecurrentDefault Settings on Line Gain :This OID configures the default gain on the line amplifier.
1.3.6.1.4.1.20044.61.9.2.1.5ScalarpmoabphcsCfglineTiltValueread-writecurrentDefault Settings on Line Tilt :This OID configures the default tilt on the line amplifier.
1.3.6.1.4.1.20044.61.9.2.1.6ScalarpmoabphcsCfglineMsaLossread-writecurrentDefault Settings on Line MSA :This OID configures the default MSA value on the line amplifier.
1.3.6.1.4.1.20044.61.9.2.1.7ScalarpmoabphcsCfglineOutputPowerValueread-writecurrentDefault Settings on Line Output power :This OID configures the default Output power value on the line amplifier.
1.3.6.1.4.1.20044.61.9.2.1.8ScalarpmoabphcsCfglineAseCompensationread-writecurrentDefault Settings on Line ASE :This OID configures the default ASE compensation value on the line amplifier.
1.3.6.1.4.1.20044.61.9.2.1.11ScalarpmoabphcsCfgaprModeread-writecurrentDefault setting on module :This OID configures the default mode on the APR
1.3.6.1.4.1.20044.61.9.3NodepmoabphcsCfgClientSupvStartUp
1.3.6.1.4.1.20044.61.9.3.1TablepmoabphcsCfgLineStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.61.9.3.1.1RowpmoabphcsCfgLineStartupEntrynot-accessiblecurrentRow definition for the clientSupvStartUp table
1.3.6.1.4.1.20044.61.9.3.1.1.1ColumnpmoabphcsCfgLineStartupIndexread-onlycurrentIndex definition for the lineStartup table
1.3.6.1.4.1.20044.61.9.3.1.1.3ColumnpmoabphcsCfgLineOscLaserCtrlPortnread-writecurrentDefault Settings on OSC Laser :This OID configures the default initialisation settings on the OSC
1.3.6.1.4.1.20044.61.9.3.1.1.4ColumnpmoabphcsCfgLineOscOosPortnread-writecurrentDefault Settings on OSC mode :This OID configures the default mode on the OSC
1.3.6.1.4.1.20044.61.9.3.1.1.5ColumnpmoabphcsCfgLineOscSpanLengthPortnread-writecurrentDefault Settings on OSC span length :This OID defines the length of the span connected on the OSC port
1.3.6.1.4.1.20044.61.9.3.1.1.6ColumnpmoabphcsCfgLineOscCorrectionFactorPortnread-writecurrentDefault Settings on OSC attenuation corrector factor :This OID defines the correction factor to apply on the span attenuation measure on the OSC Channel (1510)…
1.3.6.1.4.1.20044.61.9.4NodepmoabphcsCfgLabels
1.3.6.1.4.1.20044.61.9.4.1TablepmoabphcsCfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.61.9.4.1.1RowpmoabphcsCfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.61.9.4.1.1.1ColumnpmoabphcsCfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.61.9.4.1.1.3ColumnpmoabphcsCfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.61.9.4.2TablepmoabphcsCfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.61.9.4.2.1RowpmoabphcsCfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.61.9.4.2.1.1ColumnpmoabphcsCfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.61.9.4.2.1.3ColumnpmoabphcsCfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.61.9.257ScalarpmoabphcsCfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.61.10Nodepmoabphcstraps
1.3.6.1.4.1.20044.61.10.4ScalarpmoabphcstrapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.61.10.34NotificationpmoabphcsLineTrapCritGoesOncurrentCritical Line default is activated
1.3.6.1.4.1.20044.61.10.35NotificationpmoabphcsLineTrapCritGoesOffcurrentCritical Line default disappeared
1.3.6.1.4.1.20044.61.10.44NotificationpmoabphcsClientTrapCritGoesOncurrentCritical client default is activated
1.3.6.1.4.1.20044.61.10.45NotificationpmoabphcsClientTrapCritGoesOffcurrentCritical client default disappeared
1.3.6.1.4.1.20044.61.10.50NotificationpmoabphcsPowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.61.10.51NotificationpmoabphcsPowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared
Type Definitions
NameSyntaxStatusDescription
PmoabphcsaprModeINTEGER { oabphcsaproffmode(0), oabphcsaprsemiautomode(1), oabphcsaprautomode(2) oabphcsaprlossforwardingmode(3) oabphcsaprrepeatmode(4) }currentDifferent modes on APR
PmoabphcsBoosterCstGainAdjModeINTEGER { oabphcsboostercstgainadjsemiautomode(1), oabphcsboostercstgainadjautomode(2) }currentDifferent modes when constant Gain
PmoabphcsBoosterGainAdjModeINTEGER { oabphcsboostergainadjmanualmode(0), oabphcsboostergainadjsemiautomode(1), oabphcsboostergainadjautomode(2) }currentDifferent modes on Gain
PmoabphcsboosterModeINTEGER { oabphcsboosterdefaultmode(0), oabphcsboosterconstantcurrentmode(1), oabphcsboosterconstantpowermode(2) oabphcsboosterconstantgainmode(3) oabphcsboosterpoutpinmode(4) oabphcsboostermanualmode(5) oabphcsboosterfeedforwardmode(6) oabphcsboostertransientsupmode(7) }currentDifferent modes on OA booster
PmoabphcsPreampCstGainAdjModeINTEGER { oabphcspreampcstgainadjsemiautomode(1), oabphcspreampcstgainadjautomode(2) }currentDifferent modes when constant Gain
PmoabphcsPreampGainAdjModeINTEGER { oabphcspreampgainadjmanualmode(0), oabphcspreampgainadjsemiautomode(1), oabphcspreampgainadjautomode(2) }currentDifferent modes on Gain
PmoabphcspreampModeINTEGER { oabphcspreampdefaultmode(0), oabphcspreampconstantcurrentmode(1), oabphcspreampconstantpowermode(2) oabphcspreampconstantgainmode(3) oabphcspreamppoutpinmode(4) oabphcspreampmanualmode(5) oabphcspreampfeedforwardmode(6) oabphcspreamptransientsupmode(7) }currentDifferent modes on OA preamp