EKINOPS-Pmoac20il-MIB
317 objects
Creation
Imported Objects
| EKINOPS-MIB | EkiApiState EkiMeasureType EkiMode ekinops EkiOnOff EkiProtocol EkiState EkiSynchroMode |
| SNMPv2-SMI | Counter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20044.114 | Identitymodulepmoac20il | Creation | ||
| 1.3.6.1.4.1.20044.114.2 | Nodepmoac20ilalarms | |||
| 1.3.6.1.4.1.20044.114.2.1 | Nodepmoac20ilAlmOther | |||
| 1.3.6.1.4.1.20044.114.2.1.1 | Nodepmoac20ilAlmOtherNurg | |||
| 1.3.6.1.4.1.20044.114.2.1.1.2 | Nodepmoac20ilAlmsynthAlm2 | |||
| 1.3.6.1.4.1.20044.114.2.1.1.2.1 | Scalarpmoac20ilAlmConfTableSave | read-only | current | PM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> other… |
| 1.3.6.1.4.1.20044.114.2.1.1.2.2 | Scalarpmoac20ilAlmInvUpload | read-only | current | Inventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> other (1) <Alarmtype> other (1) <Polarit… |
| 1.3.6.1.4.1.20044.114.2.1.1.2.3 | Scalarpmoac20ilAlmConfTableLoad | read-only | current | PM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> other (1) <Alarmt… |
| 1.3.6.1.4.1.20044.114.2.1.1.75 | Nodepmoac20ilAlmfoaWarnings | |||
| 1.3.6.1.4.1.20044.114.2.1.1.75.7 | Scalarpmoac20ilAlmTermpLowWarning | read-only | current | Temperature Low Warning :This OID indicates that the PM temperature if lower than the Warning threshold <Condtype> TERMP_LOW_WARNING <Probcause> temperatureUna… |
| 1.3.6.1.4.1.20044.114.2.1.1.75.8 | Scalarpmoac20ilAlmTempHighWarning | read-only | current | Temperature High Warning :This OID indicates that the PM temperature if higher than the Warning threshold <Condtype> TEMP_HIGH_WARNING <Probcause> temperatureU… |
| 1.3.6.1.4.1.20044.114.2.1.2 | Nodepmoac20ilAlmOtherUrg | |||
| 1.3.6.1.4.1.20044.114.2.1.2.74 | Nodepmoac20ilAlmfoaAlarms | |||
| 1.3.6.1.4.1.20044.114.2.1.2.74.7 | Scalarpmoac20ilAlmTermpLowAlarm | read-only | current | Temperature Low Alarm :This OID indicates that the PM temperature if lower than the alarm threshold <Condtype> TERMP_LOW_ALARM <Probcause> temperatureUnaccepta… |
| 1.3.6.1.4.1.20044.114.2.1.2.74.8 | Scalarpmoac20ilAlmTempHighAlarm | read-only | current | Temperature High Alarm :This OID indicates that the PM temperature is higher than the alarm threshold <Condtype> TEMP_HIGH_ALARM <Probcause> temperatureUnaccep… |
| 1.3.6.1.4.1.20044.114.2.1.3 | Nodepmoac20ilAlmOtherCrit | |||
| 1.3.6.1.4.1.20044.114.2.1.3.0 | Nodepmoac20ilAlmsynthAlm0 | |||
| 1.3.6.1.4.1.20044.114.2.1.3.0.1 | Scalarpmoac20ilAlmMaintenanceMode | read-only | current | Maintenance Mode :This OID indicates that the PM is in maintenance mode <Help> This status indiates if the module is currently in maintenance mode <Condtype> M… |
| 1.3.6.1.4.1.20044.114.2.1.3.0.2 | Scalarpmoac20ilAlmAprOn | read-only | current | Automatic Power Reduction :This OID indicates that the APR algorithm has been operated and the output of the lasers are shutdown <Help> The APR algorithm has b… |
| 1.3.6.1.4.1.20044.114.2.1.3.0.9 | Scalarpmoac20ilAlmModGlobFail | read-only | current | Module Failure :This OID is set on detection of a failure originating from the PM <Condtype> MOD_GLOB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> sy… |
| 1.3.6.1.4.1.20044.114.2.1.3.0.10 | Scalarpmoac20ilAlmUpEdfaInitNotCompl | read-only | current | IL1 Not Initialized :This OID indicates that the initialisation of the IL1 is not completed <Help> This status indicates if the IL1 has been correctly initiali… |
| 1.3.6.1.4.1.20044.114.2.1.3.0.11 | Scalarpmoac20ilAlmDwEdfaInitNotCompl | read-only | current | IL2 Not Initialized :This OID indicates that the initialisation of the IL2 is not completed <Help> This status indicates if the IL2 has been correctly initiali… |
| 1.3.6.1.4.1.20044.114.2.1.3.0.12 | Scalarpmoac20ilAlmExtPump1NotLocked | read-only | current | External Pump Not Detected :This OID indicates that the first external pump is not detected by the amplifier module <Help> This alarm indicates if the external… |
| 1.3.6.1.4.1.20044.114.2.1.3.0.15 | Scalarpmoac20ilAlmDefFuseA | read-only | current | Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.114.2.1.3.0.16 | Scalarpmoac20ilAlmDefFuseB | read-only | current | Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.114.2.2 | Nodepmoac20ilAlmClient | |||
| 1.3.6.1.4.1.20044.114.2.2.1 | Nodepmoac20ilAlmClientNurg | |||
| 1.3.6.1.4.1.20044.114.2.2.1.33 | Nodepmoac20ilAlmclientEdfaWarnings | |||
| 1.3.6.1.4.1.20044.114.2.2.1.33.1 | Scalarpmoac20ilAlmClientGainLowWarning | read-only | current | IL2 Gain Low Warning :This OID indicates that the Gain is lower than the Warning threshold of the IL2 Module <Help> This alarm indicates if the IL2 gain is too… |
| 1.3.6.1.4.1.20044.114.2.2.1.33.2 | Scalarpmoac20ilAlmClientGainHighWarning | read-only | current | IL2 Gain High Warning :This OID indicates that the Gain is higher than the Warning threshold of the IL2 Module <Help> This alarm indicates if the IL2 gain is t… |
| 1.3.6.1.4.1.20044.114.2.2.1.33.3 | Scalarpmoac20ilAlmClientInputPwrLowWarning | read-only | current | IL2 Rx Pwr Low Warning :This OID indicates that the Receive Power is lower than the Warning threshold of the IL2 Optical Module <Help> This warning indicates i… |
| 1.3.6.1.4.1.20044.114.2.2.1.33.4 | Scalarpmoac20ilAlmClientInputPwrHighWarning | read-only | current | IL2 Rx Pwr High Warning :This OID indicates that the Receive Power is higher than the Warning threshold of the IL2 Optical Module <Help> This warning indicates… |
| 1.3.6.1.4.1.20044.114.2.2.1.33.5 | Scalarpmoac20ilAlmClientOutputPwrLowWarning | read-only | current | IL2 Tx Pwr Low Warning :This OID indicates that the Transmit Power is lower than the Warning threshold of the IL2 Optical Module <Help> This warning indicates … |
| 1.3.6.1.4.1.20044.114.2.2.1.33.6 | Scalarpmoac20ilAlmClientOutputPwrHighWarning | read-only | current | IL2 Tx Pwr High Warning :This OID indicates that the Transmit Power is higher than the Warning threshold of the IL2 Optical Module <Help> This warning indicate… |
| 1.3.6.1.4.1.20044.114.2.2.1.33.7 | Scalarpmoac20ilAlmClientBiasLowWarning | read-only | current | IL2 Bias Low Warning :This OID indicates that the Bias is lower than the Warning threshold of the IL2 Optical Module <Help> This warning indicates if the IL2 b… |
| 1.3.6.1.4.1.20044.114.2.2.1.33.8 | Scalarpmoac20ilAlmClientBiasHighWarning | read-only | current | IL2 Bias High Warning :This OID indicates that the Bias is higher than the Warning threshold of the IL2 Optical Module <Help> This warning indicates if the IL2… |
| 1.3.6.1.4.1.20044.114.2.2.2 | Nodepmoac20ilAlmClientUrg | |||
| 1.3.6.1.4.1.20044.114.2.2.2.32 | Nodepmoac20ilAlmclientEdfaAlarms1 | |||
| 1.3.6.1.4.1.20044.114.2.2.2.32.1 | Scalarpmoac20ilAlmClientGainLowAlarm | read-only | current | IL2 Gain Low Alarm :This OID indicates that the Gain is lower than the alarm threshold of the IL2 Module <Help> This alarm indicates if the IL2 gain is too low… |
| 1.3.6.1.4.1.20044.114.2.2.2.32.2 | Scalarpmoac20ilAlmClientGainHighAlarm | read-only | current | IL2 Gain High Alarm :This OID indicates that the Gain is higher than the alarm threshold of the IL2 Module <Help> This alarm indicates if the IL2 gain is too h… |
| 1.3.6.1.4.1.20044.114.2.2.2.32.3 | Scalarpmoac20ilAlmClientInputPwrLowAlarm | read-only | current | IL2 Rx Pwr Low Alarm :This OID indicates that the Receive Power is lower than the alarm threshold of the IL2 Optical Module <Help> This alarm indicates if the … |
| 1.3.6.1.4.1.20044.114.2.2.2.32.4 | Scalarpmoac20ilAlmClientInputPwrHighAlarm | read-only | current | IL2 Rx Pwr High Alarm :This OID indicates that the Receive Power is higher than the alarm threshold of the IL2 Optical Module <Help> This alarm indicates if th… |
| 1.3.6.1.4.1.20044.114.2.2.2.32.5 | Scalarpmoac20ilAlmClientOutputPwrLowAlarm | read-only | current | IL2 Tx Pwr Low Alarm :This OID indicates that the Transmit Power is lower than the alarm threshold of the IL2 Optical Module <Help> This alarm indicates if the… |
| 1.3.6.1.4.1.20044.114.2.2.2.32.6 | Scalarpmoac20ilAlmClientOutputPwrHighAlarm | read-only | current | IL2 Tx Pwr High Alarm :This OID indicates that the Transmit Power is higher than the alarm threshold of the IL2 Optical Module <Help> This alarm indicates if t… |
| 1.3.6.1.4.1.20044.114.2.2.2.32.7 | Scalarpmoac20ilAlmClientBiasLowAlarm | read-only | current | IL2 Bias Low Alarm :This OID indicates that the Bias is lower than the alarm threshold of the IL2 Optical Module <Help> This alarm indicates if the IL2 bias is… |
| 1.3.6.1.4.1.20044.114.2.2.2.32.8 | Scalarpmoac20ilAlmClientBiasHighAlarm | read-only | current | IL2 Bias High Alarm :This OID indicates that the Bias is higher than the alarm threshold of the IL2 Optical Module <Help> This alarm indicates if the IL2 bias … |
| 1.3.6.1.4.1.20044.114.2.2.3 | Nodepmoac20ilAlmClientCrit | |||
| 1.3.6.1.4.1.20044.114.2.2.3.8 | Nodepmoac20ilAlmsynthAlm8 | |||
| 1.3.6.1.4.1.20044.114.2.2.3.8.4 | Scalarpmoac20ilAlmClientHwFail | read-only | current | Client Port HW Failure :This OID indicates a failure on Client port, most probably caused by a HW issue <Condtype> CLIENT_HW_FAIL <Probcause> equipmentMalfunct… |
| 1.3.6.1.4.1.20044.114.2.2.3.8.5 | Scalarpmoac20ilAlmClientTxOff | read-only | current | IL2 Optical Output Shutdown :This OID indicates the IL2 optical output power is on <Help> This status indicates if the IL2 laser pump transceiver laser is ON o… |
| 1.3.6.1.4.1.20044.114.2.2.3.8.9 | Scalarpmoac20ilAlmClientDdmWarning | read-only | current | Warning On IL2 DDM :This OID indicates a warning is present coming out of the IL2 DDM <Help> This alarm indicates if a DDM Warning has been detected on the IL2… |
| 1.3.6.1.4.1.20044.114.2.2.3.8.10 | Scalarpmoac20ilAlmClientDdmAlm | read-only | current | Alarm On IL2 DDM :This OID indicates an alarm is present coming out of the Pre_Amp DDM <Help> This alarm indicates if a DDM Alarm has been detected on the IL2 … |
| 1.3.6.1.4.1.20044.114.2.2.3.8.12 | Scalarpmoac20ilAlmClientFail | read-only | current | Client Port Failure :This OID indicates a failure on the Client port <Condtype> CLIENT_FAIL <Probcause> bandwidthReduced(4) <Alarmtype> synthesisAlarm (12) <Po… |
| 1.3.6.1.4.1.20044.114.2.2.3.8.13 | Scalarpmoac20ilAlmClientExtPumpFail | read-only | current | IL2 External Pump Fail :This OID indicates that the external pump linked to the IL2 is in fail condition <Help> This alarm indicates if the external pump linke… |
| 1.3.6.1.4.1.20044.114.2.2.3.8.14 | Scalarpmoac20ilAlmSupvbFail | read-only | current | : <Condtype> SUPVB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> equipmentAlarm (5) <Polarity> (2) |
| 1.3.6.1.4.1.20044.114.2.2.3.35 | Nodepmoac20ilAlmclientEdfaAlarms2 | |||
| 1.3.6.1.4.1.20044.114.2.2.3.35.1 | Scalarpmoac20ilAlmClientEdfaNr | read-only | current | IL2 Optical Module Not Ready :This OID indicates that the IL2 Optical Module is not ready <Help> This status indicates if the IL2 has been correctly initialize… |
| 1.3.6.1.4.1.20044.114.2.2.3.35.2 | Scalarpmoac20ilAlmClientEdfaTecFail | read-only | current | IL2 TEC Fail :This OID indicates that the TEC is in fail condition on the IL2 Optical Module <Help> This alarm indicates if the TEC of the IL2 is in fail condi… |
| 1.3.6.1.4.1.20044.114.2.2.3.35.3 | Scalarpmoac20ilAlmClientEdfaLaserFail | read-only | current | IL2 Pump Laser Fail :This OID indicates a Transmit Laser Fail on the IL2 Optical Module <Help> This alarm indicates if the laser of the IL2 is in fail conditio… |
| 1.3.6.1.4.1.20044.114.2.2.3.35.4 | Scalarpmoac20ilAlmClientEdfaLos | read-only | current | IL2 Loss Of Signal :This OID indicates a Loss of Signal on the IL2 Optical Module <Help> This alarm indicates if an optical signal is detected on the IL2 input… |
| 1.3.6.1.4.1.20044.114.2.2.3.35.5 | Scalarpmoac20ilAlmClientExtPumpEdfaLowCurrent | read-only | current | IL2 Pump Low Current :This OID indicates that the EDFA pump current of IL2 is too low because of the external pump high power<Help> This alarm (only active whe… |
| 1.3.6.1.4.1.20044.114.2.2.3.35.6 | Scalarpmoac20ilAlmClientGainOutOfRange | read-only | current | IL2 Gain Out Of Range :This OID indicates the target gain of the IL2 is out of range (18-32dB), the flatness of the IL1 is not guaranteed.<Help> This alarm ind… |
| 1.3.6.1.4.1.20044.114.2.2.3.37 | Nodepmoac20ilAlmclientMsaAlarms | |||
| 1.3.6.1.4.1.20044.114.2.2.3.37.1 | Scalarpmoac20ilAlmClientMsaLos | read-only | current | IL2 MSA Loss Of Signal :This OID indicates a Loss of Signal is detected on the Mid Stage Access of the IL2 EDFAThis alarm indicates a Loss of Signal is detecte… |
| 1.3.6.1.4.1.20044.114.2.2.3.37.2 | Scalarpmoac20ilAlmClientMsaAttenuation | read-only | current | IL2 MSA Attenuation Alarm :This OID indicates the attenuation on the IL2 Mid Stage access has changed.This alarm indicates the attenuation on the IL2 Mid Stage… |
| 1.3.6.1.4.1.20044.114.2.3 | Nodepmoac20ilAlmLine | |||
| 1.3.6.1.4.1.20044.114.2.3.1 | Nodepmoac20ilAlmLineNurg | |||
| 1.3.6.1.4.1.20044.114.2.3.1.41 | Nodepmoac20ilAlmlineEdfaWarnings | |||
| 1.3.6.1.4.1.20044.114.2.3.1.41.1 | Scalarpmoac20ilAlmLineGainLowWarning | read-only | current | IL1 Gain Low Warning :This OID indicates that the Gain is lower than the Warning threshold of the IL1 Module <Help> This alarm indicates if the IL1 gain is too… |
| 1.3.6.1.4.1.20044.114.2.3.1.41.2 | Scalarpmoac20ilAlmLineGainHighWarning | read-only | current | IL1 Gain High Warning :This OID indicates that the Gain is higher than the Warning threshold of the IL1 Module <Help> This alarm indicates if the IL1 gain is t… |
| 1.3.6.1.4.1.20044.114.2.3.1.41.3 | Scalarpmoac20ilAlmLineInputPwrLowWarning | read-only | current | IL1 Rx Pwr Low Warning :This OID indicates that the Receive Power is lower than the Warning threshold of the IL1 Optical Module <Help> This warning indicates i… |
| 1.3.6.1.4.1.20044.114.2.3.1.41.4 | Scalarpmoac20ilAlmLineInputPwrHighWarning | read-only | current | IL1 Rx Pwr High Warning :This OID indicates that the Receive Power is higher than the Warning threshold of the IL1 Optical Module <Help> This warning indicates… |
| 1.3.6.1.4.1.20044.114.2.3.1.41.5 | Scalarpmoac20ilAlmLineOutputPwrLowWarning | read-only | current | IL1 Tx Pwr Low Warning :This OID indicates that the Transmit Power is lower than the Warning threshold of the IL1 Optical Module <Help> This warning indicates … |
| 1.3.6.1.4.1.20044.114.2.3.1.41.6 | Scalarpmoac20ilAlmLineOutputPwrHighWarning | read-only | current | IL1 Tx Pwr High Warning :This OID indicates that the Transmit Power is higher than the Warning threshold of the IL1 Optical Module <Help> This warning indicate… |
| 1.3.6.1.4.1.20044.114.2.3.1.41.7 | Scalarpmoac20ilAlmLineBiasLowWarning | read-only | current | IL1 Bias Low Warning :This OID indicates that the Bias is lower than the Warning threshold of the IL1 Optical Module <Help> This warning indicates if the IL1 b… |
| 1.3.6.1.4.1.20044.114.2.3.1.41.8 | Scalarpmoac20ilAlmLineBiasHighWarning | read-only | current | IL1 Bias High Warning :This OID indicates that the Bias is higher than the Warning threshold of the IL1 Optical Module <Help> This warning indicates if the IL1… |
| 1.3.6.1.4.1.20044.114.2.3.2 | Nodepmoac20ilAlmLineUrg | |||
| 1.3.6.1.4.1.20044.114.2.3.2.40 | Nodepmoac20ilAlmlineEdfaAlarms1 | |||
| 1.3.6.1.4.1.20044.114.2.3.2.40.1 | Scalarpmoac20ilAlmLineGainLowAlarm | read-only | current | IL1 Gain Low Alarm :This OID indicates that the Gain is lower than the alarm threshold of the IL1 Module <Help> This alarm indicates if the IL1 gain is too low… |
| 1.3.6.1.4.1.20044.114.2.3.2.40.2 | Scalarpmoac20ilAlmLineGainHighAlarm | read-only | current | IL1 Gain High Alarm :This OID indicates that the Gain is higher than the alarm threshold of the IL1 Module <Help> This alarm indicates if the IL1 gain is too h… |
| 1.3.6.1.4.1.20044.114.2.3.2.40.3 | Scalarpmoac20ilAlmLineInputPwrLowAlarm | read-only | current | IL1 Rx Pwr Low Alarm :This OID indicates that the Receive Power is lower than the alarm threshold of the IL1 Optical Module <Help> This alarm indicates if the … |
| 1.3.6.1.4.1.20044.114.2.3.2.40.4 | Scalarpmoac20ilAlmLineInputPwrHighAlarm | read-only | current | IL1 Rx Pwr High Alarm :This OID indicates that the Receive Power is higher than the alarm threshold of the IL1 Optical Module <Help> This alarm indicates if th… |
| 1.3.6.1.4.1.20044.114.2.3.2.40.5 | Scalarpmoac20ilAlmLineOutputPwrLowAlarm | read-only | current | IL1 Tx Pwr Low Alarm :This OID indicates that the Transmit Power is lower than the alarm threshold of the IL1 Optical Module <Help> This alarm indicates if the… |
| 1.3.6.1.4.1.20044.114.2.3.2.40.6 | Scalarpmoac20ilAlmLineOutputPwrHighAlarm | read-only | current | IL1 Tx Pwr High Alarm :This OID indicates that the Transmit Power is higher than the alarm threshold of the IL1 Optical Module <Help> This alarm indicates if t… |
| 1.3.6.1.4.1.20044.114.2.3.2.40.7 | Scalarpmoac20ilAlmLineBiasLowAlarm | read-only | current | IL1 Bias Low Alarm :This OID indicates that the Bias is lower than the alarm threshold of the IL1 Optical Module <Help> This alarm indicates if the IL1 bias is… |
| 1.3.6.1.4.1.20044.114.2.3.2.40.8 | Scalarpmoac20ilAlmLineBiasHighAlarm | read-only | current | IL1 Bias High Alarm :This OID indicates that the Bias is higher than the alarm threshold of the IL1 Optical Module <Help> This alarm indicates if the IL1 bias … |
| 1.3.6.1.4.1.20044.114.2.3.3 | Nodepmoac20ilAlmLineCrit | |||
| 1.3.6.1.4.1.20044.114.2.3.3.7 | Nodepmoac20ilAlmsynthAlm7 | |||
| 1.3.6.1.4.1.20044.114.2.3.3.7.4 | Scalarpmoac20ilAlmLineHwFail | read-only | current | Line Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Condtype> LINE_HW_FAIL <Probcause> equipmentMalfunction (1… |
| 1.3.6.1.4.1.20044.114.2.3.3.7.5 | Scalarpmoac20ilAlmLineTxOff | read-only | current | IL1 Optical Output Shutdown :This OID indicates the IL1 optical output power is on <Help> This status indicates if the IL1 laser pump is ON or OFF <Condtype> L… |
| 1.3.6.1.4.1.20044.114.2.3.3.7.9 | Scalarpmoac20ilAlmLineDdmWarning | read-only | current | Warning On IL1 DDM :This OID indicates a warning is present coming out of the IL1 DDM <Help> This alarm indicates if a DDM Warning has been detected on the IL1… |
| 1.3.6.1.4.1.20044.114.2.3.3.7.10 | Scalarpmoac20ilAlmLineDdmAlm | read-only | current | Alarm On IL1 DDM :This OID indicates an alarm is present coming out of the IL1 DDM <Help> This alarm indicates if a DDM Alarm has been detected on the IL1 <Con… |
| 1.3.6.1.4.1.20044.114.2.3.3.7.12 | Scalarpmoac20ilAlmLineFail | read-only | current | Line Port Failure :This OID indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> callEstablishmentError(5) <Alarmtype> synthesisAlarm (12) <Po… |
| 1.3.6.1.4.1.20044.114.2.3.3.7.13 | Scalarpmoac20ilAlmLineExtPumpFail | read-only | current | IL1 External Pump Fail :This OID indicates that the external pump linked to the IL1 is in fail condition <Help> This alarm indicates if the external pump linke… |
| 1.3.6.1.4.1.20044.114.2.3.3.7.14 | Scalarpmoac20ilAlmSupvaFail | read-only | current | : <Condtype> SUPVA_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> equipmentAlarm (5) <Polarity> (2) |
| 1.3.6.1.4.1.20044.114.2.3.3.43 | Nodepmoac20ilAlmlineEdfaAlarms2 | |||
| 1.3.6.1.4.1.20044.114.2.3.3.43.1 | Scalarpmoac20ilAlmLineEdfaNr | read-only | current | IL1 Optical Module Not Ready :This OID indicates that the IL1 Optical Module is not ready <Help> This status indicates if the IL1 has been correctly initialize… |
| 1.3.6.1.4.1.20044.114.2.3.3.43.2 | Scalarpmoac20ilAlmLineEdfaTecFail | read-only | current | IL1 TEC Fail :This OID indicates that the TEC is in fail condition on the IL1 Optical Module <Help> This alarm indicates if the TEC of the IL1 is in fail condi… |
| 1.3.6.1.4.1.20044.114.2.3.3.43.3 | Scalarpmoac20ilAlmLineEdfaLaserFail | read-only | current | IL1 Pump Laser Fail :This OID indicates a Transmit Laser Fail on the IL1 Optical Module <Help> This alarm indicates if the laser of the IL1 is in fail conditio… |
| 1.3.6.1.4.1.20044.114.2.3.3.43.4 | Scalarpmoac20ilAlmLineEdfaLos | read-only | current | IL1 Loss Of Signal :This OID indicates a Loss of Signal on the IL1 Optical Module <Help> This alarm indicates if an optical signal is detected on the IL1 input… |
| 1.3.6.1.4.1.20044.114.2.3.3.43.5 | Scalarpmoac20ilAlmLineExtPumpEdfaLowCurrent | read-only | current | IL1 Pump Low Current :This OID indicates that the EDFA pump current of IL1 is too low because of the external pump high power<Help> This alarm (only active whe… |
| 1.3.6.1.4.1.20044.114.2.3.3.43.6 | Scalarpmoac20ilAlmLineGainOutOfRange | read-only | current | IL1 Gain Out Of Range :This OID indicates the target gain of the IL1 is out of range (10-18dB), the flatness of the IL1 is not guaranteed.<Help> This alarm ind… |
| 1.3.6.1.4.1.20044.114.2.3.3.45 | Nodepmoac20ilAlmlineMsaAlarms | |||
| 1.3.6.1.4.1.20044.114.2.3.3.45.1 | Scalarpmoac20ilAlmLineMsaLos | read-only | current | IL1 MSA Loss Of Signal :This OID indicates a Loss of Signal is detected on the Mid Stage Access of the IL1 EDFAThis alarm indicates a Loss of Signal is detecte… |
| 1.3.6.1.4.1.20044.114.2.3.3.45.2 | Scalarpmoac20ilAlmLineMsaAttenuation | read-only | current | IL1 MSA Attenuation Alarm :This OID indicates the attenuation on the IL1 Mid Stage access has changed.This alarm indicates the attenuation on the IL2 Mid Stage… |
| 1.3.6.1.4.1.20044.114.2.3.3.48 | Tablepmoac20ilAlmlineOscAlarmsTable | not-accessible | current | List of pmoac20ilAlmlineOscAlarms Article |
| 1.3.6.1.4.1.20044.114.2.3.3.48.1 | Rowpmoac20ilAlmlineOscAlarmsEntry | not-accessible | current | Row definition for the pmoac20ilAlmlineOscAlarms table |
| 1.3.6.1.4.1.20044.114.2.3.3.48.1.1 | Columnpmoac20ilAlmlineOscAlarmsIndex | read-only | current | Index definition for the pmoac20ilAlmlineOscAlarms table |
| 1.3.6.1.4.1.20044.114.2.3.3.48.1.2 | Columnpmoac20ilAlmLineLosPortn | read-only | current | OSC Loss Of Signal :This OID indicates that no signal is present on the OSC <Help> This alarms indicates that no signal is present on the OSC <Condtype> LINE_L… |
| 1.3.6.1.4.1.20044.114.2.3.3.48.1.3 | Columnpmoac20ilAlmLineTxOffPortn | read-only | current | OSC Optical Output Shutdown :This OID indicates the optical output power is shutdown on OSC<Help> This alarm indicates the optical output power is shutdown on … |
| 1.3.6.1.4.1.20044.114.2.3.3.48.1.4 | Columnpmoac20ilAlmLineTxFailPortn | read-only | current | OSC Tx Fail :This OID indicates the OSC Laser is in fail condition<Help> This alarm indicates the OSC Laser is in fail condition <Condtype> LINE_TX_FAIL_1 <Pro… |
| 1.3.6.1.4.1.20044.114.2.3.3.48.1.6 | Columnpmoac20ilAlmLineOosPortn | read-only | current | OSC In Service :This OID indicates that the OSC is In Service (1) or Out or Service (2)<Help> This status indicates that the OSC is In Service or Out or Servic… |
| 1.3.6.1.4.1.20044.114.2.3.3.48.1.10 | Columnpmoac20ilAlmLineWarningPortn | read-only | current | OSC DDM Warning :This OID indicates a warning is present on OSC Tx power, Receive power or temperature<Help> This alarm indicates a warning is present on OSC T… |
| 1.3.6.1.4.1.20044.114.2.3.3.48.1.11 | Columnpmoac20ilAlmLineAlmPortn | read-only | current | OSC DDM Alarm :This alarm indicates an alarm is present on OSC Tx power, Rx power or temperature <Help> This alarm indicates an alarm is present on OSC Tx powe… |
| 1.3.6.1.4.1.20044.114.2.3.3.49 | Tablepmoac20ilAlmlineOscThresholdAlarmsTable | not-accessible | current | List of pmoac20ilAlmlineOscThresholdAlarms Article |
| 1.3.6.1.4.1.20044.114.2.3.3.49.1 | Rowpmoac20ilAlmlineOscThresholdAlarmsEntry | not-accessible | current | Row definition for the pmoac20ilAlmlineOscThresholdAlarms table |
| 1.3.6.1.4.1.20044.114.2.3.3.49.1.1 | Columnpmoac20ilAlmlineOscThresholdAlarmsIndex | read-only | current | Index definition for the pmoac20ilAlmlineOscThresholdAlarms table |
| 1.3.6.1.4.1.20044.114.2.3.3.49.1.2 | Columnpmoac20ilAlmLineOscTxPwrLowAlarmPortn | read-only | current | OSC Tx Power Low Alarm :This OID indicates the Tx Power of the OSC is lower than the warning threshold<Help> This alarm indicates the Tx Power of the OSC is lo… |
| 1.3.6.1.4.1.20044.114.2.3.3.49.1.3 | Columnpmoac20ilAlmLineOscTxPwrHighAlarmPortn | read-only | current | OSC Tx Power High Alarm :This OID indicates the Tx Power of the OSC is higher than the warning threshold<Help> This alarm indicates the Tx Power of the OSC is … |
| 1.3.6.1.4.1.20044.114.2.3.3.49.1.4 | Columnpmoac20ilAlmLineOscTxBiasLowAlarmPortn | read-only | current | OSC Bias Current Low Alarm :This OID indicates the OSC bias current is lower than the alarm threshold <Help> This alarm indicates the OSC bias current is lower… |
| 1.3.6.1.4.1.20044.114.2.3.3.49.1.5 | Columnpmoac20ilAlmLineOscTxBiasHighAlarmPortn | read-only | current | OSC Bias Current High Alarm :This OID indicates the OSC bias current is higher than the alarm threshold <Help> This alarm indicates the OSC bias current is hig… |
| 1.3.6.1.4.1.20044.114.2.3.3.49.1.6 | Columnpmoac20ilAlmLineOscVccLowAlarmPortn | read-only | current | OSC Vcc Low Alarm :This OID indicates the Vcc of the OSC is lower than the warning threshold<Help> This alarm indicates the Vcc of the OSC is lower than the al… |
| 1.3.6.1.4.1.20044.114.2.3.3.49.1.7 | Columnpmoac20ilAlmLineOscVccHighAlarmPortn | read-only | current | OSC Vcc High Alarm :This OID indicates the Vcc of the OSC is higher than the warning threshold<Help> This alarm indicates the Vcc of the OSC is higher than the… |
| 1.3.6.1.4.1.20044.114.2.3.3.49.1.8 | Columnpmoac20ilAlmLineOscTempLowAlarmPortn | read-only | current | OSC Temperature Low Alarm :This OID indicates the OSC temperature is lower than the alarm threshold <Help> This alarm indicates the OSC temperature is lower th… |
| 1.3.6.1.4.1.20044.114.2.3.3.49.1.9 | Columnpmoac20ilAlmLineOscTempHighAlarmPortn | read-only | current | OSC Temperature High Alarm :This OID indicates the OSC temperature is higher than the alarm threshold <Help> This alarm indicates the OSC temperature is higher… |
| 1.3.6.1.4.1.20044.114.2.3.3.49.1.10 | Columnpmoac20ilAlmLineOscSpanlossLowAlarmPortn | read-only | current | OSC Span Loss Low Alarm :This OID indicates the OSC Span Loss is 3dB lower than the span loss reference<Help> This alarm indicates the OSC Span Loss is 3dB low… |
| 1.3.6.1.4.1.20044.114.2.3.3.49.1.11 | Columnpmoac20ilAlmLineOscSpanlossHighAlarmPortn | read-only | current | OSC Span Loss High Alarm :This OID indicates the OSC Span Loss is 3dB higher than the span loss reference <Help> This alarm indicates the OSC Span Loss is 3dB … |
| 1.3.6.1.4.1.20044.114.2.3.3.49.1.16 | Columnpmoac20ilAlmLineOscRxPwrLowAlarmPortn | read-only | current | OSC Rx Power Low Alarm :This OID indicates the Rx Power of the OSC is lower than the alarm threshold<Help> This alarm indicates the Rx Power of the OSC is lowe… |
| 1.3.6.1.4.1.20044.114.2.3.3.49.1.17 | Columnpmoac20ilAlmLineOscRxPwrHighAlarmPortn | read-only | current | OSC Rx Power High Alarm :This OID indicates the Rx Power of the OSC is higher than the alarm threshold<Help> This alarm indicates the Rx Power of the OSC is hi… |
| 1.3.6.1.4.1.20044.114.2.3.3.50 | Tablepmoac20ilAlmlineOscThresholdsWarningsTable | not-accessible | current | List of pmoac20ilAlmlineOscThresholdsWarnings Article |
| 1.3.6.1.4.1.20044.114.2.3.3.50.1 | Rowpmoac20ilAlmlineOscThresholdsWarningsEntry | not-accessible | current | Row definition for the pmoac20ilAlmlineOscThresholdsWarnings table |
| 1.3.6.1.4.1.20044.114.2.3.3.50.1.1 | Columnpmoac20ilAlmlineOscThresholdsWarningsIndex | read-only | current | Index definition for the pmoac20ilAlmlineOscThresholdsWarnings table |
| 1.3.6.1.4.1.20044.114.2.3.3.50.1.2 | Columnpmoac20ilAlmLineOscTxPwrLowWarningPortn | read-only | current | OSC Tx Power Low Warning :This OID indicates the Tx Power of the OSC is lower than the warning threshold<Help> This alarm indicates the Tx Power of the OSC is … |
| 1.3.6.1.4.1.20044.114.2.3.3.50.1.3 | Columnpmoac20ilAlmLineOscTxPwrHighWarningPortn | read-only | current | OSC Tx Power High Warning :This OID indicates the Tx Power of the OSC is higher than the warning threshold<Help> This alarm indicates the Tx Power of the OSC i… |
| 1.3.6.1.4.1.20044.114.2.3.3.50.1.4 | Columnpmoac20ilAlmLineOscTxBiasLowWarningPortn | read-only | current | OSC Bias Current Low Warning :This OID indicates the OSC bias current is lower than the warning threshold <Help> This alarm indicates the OSC bias current is l… |
| 1.3.6.1.4.1.20044.114.2.3.3.50.1.5 | Columnpmoac20ilAlmLineOscTxBiasHighWarningPortn | read-only | current | OSC Bias Current High Warning :This OID indicates the OSC bias current is higher than the warning threshold <Help> This alarm indicates the OSC bias current is… |
| 1.3.6.1.4.1.20044.114.2.3.3.50.1.6 | Columnpmoac20ilAlmLineOscVccLowWarningPortn | read-only | current | OSC Vcc Low Warning :This OID indicates the Vcc of the OSC is lower than the warning threshold<Help> This alarm indicates the Vcc of the OSC is lower than the … |
| 1.3.6.1.4.1.20044.114.2.3.3.50.1.7 | Columnpmoac20ilAlmLineOscVccHighWarningPortn | read-only | current | OSC Vcc High Warning :This OID indicates the Vcc of the OSC is higher than the warning threshold<Help> This alarm indicates the Vcc of the OSC is higher than t… |
| 1.3.6.1.4.1.20044.114.2.3.3.50.1.8 | Columnpmoac20ilAlmLineOscTempLowWarningPortn | read-only | current | OSC Temperature Low Warning :This OID indicates the OSC temperature is lower than the warning threshold <Help> This alarm indicates the OSC temperature is lowe… |
| 1.3.6.1.4.1.20044.114.2.3.3.50.1.9 | Columnpmoac20ilAlmLineOscTempHighWarningPortn | read-only | current | OSC Temperature High Warning :This OID indicates the OSC temperature is higher than the warning threshold <Help> This alarm indicates the OSC temperature is hi… |
| 1.3.6.1.4.1.20044.114.2.3.3.50.1.10 | Columnpmoac20ilAlmLineOscSpanlossLowWarningPortn | read-only | current | OSC Span Loss Low Warning :This OID indicates the OSC Span Loss is 1dB lower than the span loss reference<Help> This alarm indicates the OSC Span Loss is 1dB l… |
| 1.3.6.1.4.1.20044.114.2.3.3.50.1.11 | Columnpmoac20ilAlmLineOscSpanlossHighWarningPortn | read-only | current | OSC Span Loss High Warning :This OID indicates the OSC Span Loss is 1dB higher than the span loss reference <Help> This alarm indicates the OSC Span Loss is 1d… |
| 1.3.6.1.4.1.20044.114.2.3.3.50.1.16 | Columnpmoac20ilAlmLineOscRxPwrLowWarningPortn | read-only | current | OSC Rx Power Low Warning :This OID indicates the Rx Power of the OSC is lower than the warning threshold<Help> This alarm indicates the Rx Power of the OSC is … |
| 1.3.6.1.4.1.20044.114.2.3.3.50.1.17 | Columnpmoac20ilAlmLineOscRxPwrHighWarningPortn | read-only | current | OSC Rx Power High Warning :This OID indicates the Rx Power of the OSC is higher than the warning threshold<Help> This alarm indicates the Rx Power of the OSC i… |
| 1.3.6.1.4.1.20044.114.3 | Nodepmoac20ilmeasures | |||
| 1.3.6.1.4.1.20044.114.3.1 | Nodepmoac20ilMesrOther | |||
| 1.3.6.1.4.1.20044.114.3.1.80 | Scalarpmoac20ilMesrtempMeas | read-only | current | Module Temperature :This OID gives the temperature of the PM (Temperature =AV_S16/256) (Unit = C) <Help> This measure gives the temperature of the module |
| 1.3.6.1.4.1.20044.114.3.1.82 | Scalarpmoac20ilMesrmoduleTempMin | read-only | current | Min Module Temperature :This OID gives the minimum temperature value of the Module (Temperature = AV_S16/256) (Unit = C) <Help> This Measure gives the minimum … |
| 1.3.6.1.4.1.20044.114.3.1.83 | Scalarpmoac20ilMesrmoduleTempMax | read-only | current | Max Module Temperature :This OID gives the maximum temperature value of the Module (Temperature = AV_S16/256) (Unit = C) <Help> This Measure gives the maximum … |
| 1.3.6.1.4.1.20044.114.3.2 | Nodepmoac20ilMesrClient | |||
| 1.3.6.1.4.1.20044.114.3.2.32 | Scalarpmoac20ilMesrclientEdfaBiasMeas | read-only | current | IL2 Pump Laser Current :This OID gives the pump laser current of the IL2 Optical Module (Current =AV_U16/20) (Unit = mA) <Help> This measure gives the bias of … |
| 1.3.6.1.4.1.20044.114.3.2.33 | Scalarpmoac20ilMesrclientEdfaTxpwrMeas | read-only | current | IL2 Tx Power :This OID gives the transmit power value of the IL2 Optical Module (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure gives the Tx opt… |
| 1.3.6.1.4.1.20044.114.3.2.34 | Scalarpmoac20ilMesrclientEdfaRxpwrMeas | read-only | current | IL2 Rx Power :This OID gives the receive power value of the IL2 Optical Module (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure gives the Rx opti… |
| 1.3.6.1.4.1.20044.114.3.2.35 | Scalarpmoac20ilMesrclientEdfaGainMeas | read-only | current | IL2 Gain Target :This OID gives the gain value of the IL2 Module (Gain =(AV_U16-32768)*0.005) (Unit = dB) <Help> This information gives the target gain of the … |
| 1.3.6.1.4.1.20044.114.3.2.36 | Scalarpmoac20ilMesrclientOscSpanLoss | read-only | current | IL2 Input Span Loss :This OID indicates the attenuation of the span connected to the IL2 input (Power =(AV_U16-32768)*0.005) (Unit = dB) <Help> This measure in… |
| 1.3.6.1.4.1.20044.114.3.2.37 | Scalarpmoac20ilMesrclientOscSpanLossRef | read-only | current | IL2 Input Span Loss Ref :This OID indicates the referenced attenuation of the span connected to the IL2 input (Used to monitor the variation of the span loss) … |
| 1.3.6.1.4.1.20044.114.3.2.38 | Scalarpmoac20ilMesrclientCorrectedGain | read-only | current | IL2 Gain :This OID gives the gain value of the IL2 Module corrected by the ASE compensation mechanism (Gain =(AV_U16-32768)*0.005) (Unit = dB) <Help> This meas… |
| 1.3.6.1.4.1.20044.114.3.2.39 | Scalarpmoac20ilMesrclientMsaInputPower | read-only | current | IL2 MSA Rx Power :This OID indicates the input power of the Mid Stage Access of the IL2 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicate… |
| 1.3.6.1.4.1.20044.114.3.2.40 | Scalarpmoac20ilMesrclientMsaOutputPower | read-only | current | IL2 MSA Tx Power :This OID indicates the output power of the Mid Stage Access of the IL2 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicat… |
| 1.3.6.1.4.1.20044.114.3.2.41 | Scalarpmoac20ilMesrclientMsaAttenuation | read-only | current | IL2 MSA Attenuation :This OID indicates the attenuation applied on the Mid Stage Access of the IL2 (Attenuation =(AV_U16-32768)*0.005) (Unit = dB) <Help> This … |
| 1.3.6.1.4.1.20044.114.3.2.42 | Scalarpmoac20ilMesrclientMsaAttenuationRef | read-only | current | IL2 MSA Attenuation Ref :This OID indicates the reference attenuation stored for the Mid Stage Access of the In-Line1 (Used to monitor the variation of this at… |
| 1.3.6.1.4.1.20044.114.3.3 | Nodepmoac20ilMesrLine | |||
| 1.3.6.1.4.1.20044.114.3.3.48 | Scalarpmoac20ilMesrlineEdfaBiasMeas | read-only | current | IL1 Pump Laser Current :This OID gives the pump laser current of the IL1 Optical Module (Current =AV_U16/20) (Unit = mA) <Help> This measure gives the bias of … |
| 1.3.6.1.4.1.20044.114.3.3.49 | Scalarpmoac20ilMesrlineEdfaTxpwrMeas | read-only | current | IL1 Tx Power :This OID gives the transmit power value of the IL1 Optical Module (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure gives the Tx opt… |
| 1.3.6.1.4.1.20044.114.3.3.50 | Scalarpmoac20ilMesrlineEdfaRxpwrMeas | read-only | current | IL1 Rx Power :This OID gives the receive power value of the IL1 Optical Module (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure gives the Rx opti… |
| 1.3.6.1.4.1.20044.114.3.3.51 | Scalarpmoac20ilMesrlineEdfaGainMeas | read-only | current | IL1 Gain Target :This OID gives the gain value of the IL1 Module (Gain =(AV_U16-32768)*0.005) (Unit = dB) <Help> This information gives the target gain of the … |
| 1.3.6.1.4.1.20044.114.3.3.52 | Scalarpmoac20ilMesrlineOscSpanLoss | read-only | current | IL1 Input Span Loss :This OID indicates the attenuation of the span connected to the IL1 input (Power =(AV_U16-32768)*0.005) (Unit = dB) <Help> This measure in… |
| 1.3.6.1.4.1.20044.114.3.3.53 | Scalarpmoac20ilMesrlineOscSpanLossRef | read-only | current | IL1 Input Span Loss Ref :This OID indicates the referenced attenuation of the span connected to the IL1 input (Used to monitor the variation of the span loss) … |
| 1.3.6.1.4.1.20044.114.3.3.54 | Scalarpmoac20ilMesrlineCorrectedGain | read-only | current | IL1 Gain :This OID gives the gain value of the IL1 Module corrected by the ASE compensation mechanism (Gain =(AV_U16-32768)*0.005) (Unit = dB) <Help> This meas… |
| 1.3.6.1.4.1.20044.114.3.3.55 | Scalarpmoac20ilMesrlineMsaInputPower | read-only | current | IL1 MSA Rx Power :This OID indicates the input power of the Mid Stage Access of the IL1 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicate… |
| 1.3.6.1.4.1.20044.114.3.3.56 | Scalarpmoac20ilMesrlineMsaOutputPower | read-only | current | IL1 MSA Tx Power :This OID indicates the output power of the Mid Stage Access of the IL1 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicat… |
| 1.3.6.1.4.1.20044.114.3.3.57 | Scalarpmoac20ilMesrlineMsaAttenuation | read-only | current | IL1 MSA Attenuation :This OID indicates the attenuation applied on the Mid Stage Access of the IL1 (Attenuation =(AV_U16-32768)*0.005) (Unit = dB) <Help> This … |
| 1.3.6.1.4.1.20044.114.3.3.58 | Scalarpmoac20ilMesrlineMsaAttenuationRef | read-only | current | IL1 MSA Attenuation Ref :This OID indicates the reference attenuation stored for the Mid Stage Access of the IL1 (Used to monitor the variation of this attenua… |
| 1.3.6.1.4.1.20044.114.3.3.64 | Tablepmoac20ilMesrlineOscTxPowerTable | not-accessible | current | List of pmoac20ilMesrlineOscTxPower Article |
| 1.3.6.1.4.1.20044.114.3.3.64.1 | Rowpmoac20ilMesrlineOscTxPowerEntry | not-accessible | current | Row definition for the pmoac20ilMesrlineOscTxPower table |
| 1.3.6.1.4.1.20044.114.3.3.64.1.1 | Columnpmoac20ilMesrlineOscTxPowerIndex | read-only | current | Index definition for the pmoac20ilMesrlineOscTxPower table |
| 1.3.6.1.4.1.20044.114.3.3.64.1.2 | Columnpmoac20ilMesrlineOscTxPowerPortn | read-only | current | OSC Tx Power :This OID gives the transmit power value of the Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit =… |
| 1.3.6.1.4.1.20044.114.3.3.65 | Tablepmoac20ilMesrlineOscRxPowerTable | not-accessible | current | List of pmoac20ilMesrlineOscRxPower Article |
| 1.3.6.1.4.1.20044.114.3.3.65.1 | Rowpmoac20ilMesrlineOscRxPowerEntry | not-accessible | current | Row definition for the pmoac20ilMesrlineOscRxPower table |
| 1.3.6.1.4.1.20044.114.3.3.65.1.1 | Columnpmoac20ilMesrlineOscRxPowerIndex | read-only | current | Index definition for the pmoac20ilMesrlineOscRxPower table |
| 1.3.6.1.4.1.20044.114.3.3.65.1.2 | Columnpmoac20ilMesrlineOscRxPowerPortn | read-only | current | OSC Rx Power :This OID gives the receive power value of the Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dB… |
| 1.3.6.1.4.1.20044.114.3.3.66 | Tablepmoac20ilMesrlineOscBiasTable | not-accessible | current | List of pmoac20ilMesrlineOscBias Article |
| 1.3.6.1.4.1.20044.114.3.3.66.1 | Rowpmoac20ilMesrlineOscBiasEntry | not-accessible | current | Row definition for the pmoac20ilMesrlineOscBias table |
| 1.3.6.1.4.1.20044.114.3.3.66.1.1 | Columnpmoac20ilMesrlineOscBiasIndex | read-only | current | Index definition for the pmoac20ilMesrlineOscBias table |
| 1.3.6.1.4.1.20044.114.3.3.66.1.2 | Columnpmoac20ilMesrlineOscBiasPortn | read-only | current | OSC Bias :This OID gives the Laser bias value of the Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV_U16/500) (Unit = mA) <Help> This… |
| 1.3.6.1.4.1.20044.114.3.3.67 | Tablepmoac20ilMesrlineOscTempTable | not-accessible | current | List of pmoac20ilMesrlineOscTemp Article |
| 1.3.6.1.4.1.20044.114.3.3.67.1 | Rowpmoac20ilMesrlineOscTempEntry | not-accessible | current | Row definition for the pmoac20ilMesrlineOscTemp table |
| 1.3.6.1.4.1.20044.114.3.3.67.1.1 | Columnpmoac20ilMesrlineOscTempIndex | read-only | current | Index definition for the pmoac20ilMesrlineOscTemp table |
| 1.3.6.1.4.1.20044.114.3.3.67.1.2 | Columnpmoac20ilMesrlineOscTempPortn | read-only | current | OSC Temperature :This OID gives the Laser temperature value of the Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV_S16/256) (U… |
| 1.3.6.1.4.1.20044.114.3.3.68 | Tablepmoac20ilMesrlineOscVoltTable | not-accessible | current | List of pmoac20ilMesrlineOscVolt Article |
| 1.3.6.1.4.1.20044.114.3.3.68.1 | Rowpmoac20ilMesrlineOscVoltEntry | not-accessible | current | Row definition for the pmoac20ilMesrlineOscVolt table |
| 1.3.6.1.4.1.20044.114.3.3.68.1.1 | Columnpmoac20ilMesrlineOscVoltIndex | read-only | current | Index definition for the pmoac20ilMesrlineOscVolt table |
| 1.3.6.1.4.1.20044.114.3.3.68.1.2 | Columnpmoac20ilMesrlineOscVoltPortn | read-only | current | OSC Voltage :This OID gives the Voltage value of the Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV_U16/10000) (Unit = V) <Help> … |
| 1.3.6.1.4.1.20044.114.6 | Nodepmoac20ilcontrolsWrite | |||
| 1.3.6.1.4.1.20044.114.6.1 | Nodepmoac20ilCtrlOther | |||
| 1.3.6.1.4.1.20044.114.6.1.0 | Nodepmoac20ilCtrlsynth0 | |||
| 1.3.6.1.4.1.20044.114.6.1.0.1 | Scalarpmoac20ilCtrlConfLoad | read-write | current | Load Configuration Tables :When set this enables loading from flash configuration1 into the module. |
| 1.3.6.1.4.1.20044.114.6.1.0.9 | Scalarpmoac20ilCtrlConfFlash | read-write | current | Write Configuration Tables :This bit saves the current configuration of the module as configuration in the flash. <Help> This control saves the customer config… |
| 1.3.6.1.4.1.20044.114.6.1.0.13 | Scalarpmoac20ilCtrlConfClear | read-write | current | Clear Configuration Tables :This bit clears the configuration tables from configuration in the flash. <Help> This control restores the default configuration of… |
| 1.3.6.1.4.1.20044.114.6.1.5 | Nodepmoac20ilCtrlswMgnt | |||
| 1.3.6.1.4.1.20044.114.6.1.5.2 | Scalarpmoac20ilCtrlColdReset | read-write | current | PM Cold Reset :This OID, when set, causes a cold reset of the Software. This reset is traffic affecting, and the configuration of Software is reloaded on start… |
| 1.3.6.1.4.1.20044.114.6.1.5.3 | Scalarpmoac20ilCtrlWarmReset | read-write | current | PM Warm Reset :This OID, when set, causes a warm reset of the Software. This reset is not traffic affecting, and the configuration of the Sofwtare remains unch… |
| 1.3.6.1.4.1.20044.114.6.1.6 | Nodepmoac20ilCtrlsynth6 | |||
| 1.3.6.1.4.1.20044.114.6.1.6.1 | Scalarpmoac20ilCtrlCurrentGwReset | read-write | current | Active Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting. |
| 1.3.6.1.4.1.20044.114.6.1.73 | Nodepmoac20ilCtrlledTest | |||
| 1.3.6.1.4.1.20044.114.6.1.73.1 | Scalarpmoac20ilCtrlGreenLed | read-write | current | Green Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green |
| 1.3.6.1.4.1.20044.114.6.1.73.2 | Scalarpmoac20ilCtrlRedLed | read-write | current | Red Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red |
| 1.3.6.1.4.1.20044.114.6.1.73.3 | Scalarpmoac20ilCtrlLedOff | read-write | current | Leds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF |
| 1.3.6.1.4.1.20044.114.6.1.75 | Nodepmoac20ilCtrlmaintMode | |||
| 1.3.6.1.4.1.20044.114.6.1.75.1 | Scalarpmoac20ilCtrlMaintenance | read-write | current | PM Maintenance Mode :This OID sets the PM in maintenance mode <Help> This control enables the maintenance mode of the module |
| 1.3.6.1.4.1.20044.114.6.1.76 | Nodepmoac20ilCtrlaprRestart | |||
| 1.3.6.1.4.1.20044.114.6.1.76.1 | Scalarpmoac20ilCtrlAprManualRestart | read-write | current | APR Manual Restart :This OID initiates the Restart mechanism to retrieve from the APR state.<Help> This control initiates the Restart mechanism to retrieve fro… |
| 1.3.6.1.4.1.20044.114.6.2 | Nodepmoac20ilCtrlClient | |||
| 1.3.6.1.4.1.20044.114.6.2.33 | Nodepmoac20ilCtrlclientOscInputSpanLoss | |||
| 1.3.6.1.4.1.20044.114.6.2.33.1 | Scalarpmoac20ilCtrlClientSpanLoss | read-write | current | Store IL2 Input Span Loss :This OID stores the current input span Loss as a reference to monitor the span loss variation <Help> This parameter stores the curre… |
| 1.3.6.1.4.1.20044.114.6.2.34 | Scalarpmoac20ilCtrlclientGainCstMonitorValue | read-write | current | IL2 Fiber Aging Period :This OID sets the value of the monitoring period to detect a fiber aging. (Unit = s) This value sets the monitoring period to detect a … |
| 1.3.6.1.4.1.20044.114.6.2.36 | Scalarpmoac20ilCtrlclientGainSettingValue | read-write | current | IL2 Gain Target :This OID sets the value of the nominal gain of the IL2lifier Module (active only in constant output power mode) (AV=(Gain/0,005) + 32768) (Uni… |
| 1.3.6.1.4.1.20044.114.6.2.37 | Nodepmoac20ilCtrlclientGainProcessing | |||
| 1.3.6.1.4.1.20044.114.6.2.37.1 | Scalarpmoac20ilCtrlClientGainProc | read-write | current | IL2 Fiber Aging Compensation :This OID initiates the automatic nominal gain adjustment on the IL2lifier Module<Help> This control initiates the automatic nomin… |
| 1.3.6.1.4.1.20044.114.6.2.38 | Scalarpmoac20ilCtrlclientGainCstFiberAgingMarginValue | read-write | current | IL2 Aging Threshold :This OID sets the threshold to consider the power drop as a fiber aging. (active only in constant gain mode) (AV=(Gain/0,005) + 32768) (Un… |
| 1.3.6.1.4.1.20044.114.6.2.40 | Nodepmoac20ilCtrlclientMsaAttenuationValue | |||
| 1.3.6.1.4.1.20044.114.6.2.40.1 | Scalarpmoac20ilCtrlClientAttenuation | read-write | current | Store IL2 MSA Attenuation :This OID stores the current attenuation applied on the Mid Stage Access of the IL2 (used for monitoring the MSA attenuation variatio… |
| 1.3.6.1.4.1.20044.114.6.2.41 | Scalarpmoac20ilCtrlclientTlvPreviousAmpPwrW | read-write | current | Previous Amplifier Output Power :This OID sets the value of the previous Amplifier output power to be used to compute the local span loss monitoring (AV=(Gain/… |
| 1.3.6.1.4.1.20044.114.6.2.42 | Scalarpmoac20ilCtrlclientTlvPreviousRoadmLambdaNbW | read-write | current | Previous Roadm Lambda Number :This OID sets the value of the previous Roadm wavelength number to be computed locally (Unit = Lambdas) <Help> This parameter sto… |
| 1.3.6.1.4.1.20044.114.6.2.57 | Scalarpmoac20ilCtrllineTlvPreviousAmpPwrW | read-write | current | Previous Amplifier Output Power :This OID sets the value of the previous Amplifier output power to be used to compute the local span loss monitoring (AV=(Gain/… |
| 1.3.6.1.4.1.20044.114.6.2.58 | Scalarpmoac20ilCtrllineTlvPreviousRoadmLambdaNbW | read-write | current | Previous Roadm Lambda Number :This OID sets the value of the previous Roadm wavelength number to be computed locally (Unit = Lambdas) <Help> This parameter sto… |
| 1.3.6.1.4.1.20044.114.6.3 | Nodepmoac20ilCtrlLine | |||
| 1.3.6.1.4.1.20044.114.6.3.49 | Nodepmoac20ilCtrllineOscInputSpanLoss | |||
| 1.3.6.1.4.1.20044.114.6.3.49.1 | Scalarpmoac20ilCtrlLineSpanLoss | read-write | current | Store IL1 Input Span Loss :This OID stores the current input span Loss as a reference to monitor the span loss variation<Help> This parameter stores the curren… |
| 1.3.6.1.4.1.20044.114.6.3.50 | Scalarpmoac20ilCtrllineGainCstMonitorValue | read-write | current | IL1 Fiber Aging Period :This OID sets the value of the monitoring period to detect a fiber aging. (Unit = s) This value sets the monitoring period to detect a … |
| 1.3.6.1.4.1.20044.114.6.3.52 | Scalarpmoac20ilCtrllineGainSettingValue | read-write | current | IL1 Gain Target :This OID sets the value of the nominal gain of the IL1 Module (active only in constant output power mode) (AV=(Gain/0,005) + 32768) (Unit = dB… |
| 1.3.6.1.4.1.20044.114.6.3.53 | Nodepmoac20ilCtrllineGainProcessing | |||
| 1.3.6.1.4.1.20044.114.6.3.53.1 | Scalarpmoac20ilCtrlLineGainProc | read-write | current | IL1 Fiber Aging Compensation :This OID initiates the automatic nominal gain adjustment on the IL1 Module<Help> This control initiates the automatic nominal gai… |
| 1.3.6.1.4.1.20044.114.6.3.54 | Scalarpmoac20ilCtrllineGainCstFiberAgingMarginValue | read-write | current | IL1 Aging Threshold :This OID sets the threshold to consider the power drop as a fiber aging. (active only in constant gain mode) (AV=(Gain/0,005) + 32768) (Un… |
| 1.3.6.1.4.1.20044.114.6.3.56 | Nodepmoac20ilCtrllineMsaAttenuationValue | |||
| 1.3.6.1.4.1.20044.114.6.3.56.1 | Scalarpmoac20ilCtrlLineAttenuation | read-write | current | Store IL1 MSA Attenuation :This OID stores the current attenuation applied on the Mid Stage Access of the IL1 (used for monitoring the MSA attenuation variatio… |
| 1.3.6.1.4.1.20044.114.7 | Nodepmoac20ilri | |||
| 1.3.6.1.4.1.20044.114.7.2 | Scalarpmoac20ilRinvReloadInventory | read-write | current | Reload the inventory: This OID triggers an inventory reload. |
| 1.3.6.1.4.1.20044.114.7.3 | Scalarpmoac20ilRinvHwPlatform | read-only | current | HW platform description: This OID contains the description of the Hardware platform. |
| 1.3.6.1.4.1.20044.114.7.4 | Scalarpmoac20ilRinvModulePlatform | read-only | current | Module platform description: This OID contains the description of the Module. |
| 1.3.6.1.4.1.20044.114.7.5 | Scalarpmoac20ilRinvSwPlatform | read-only | current | SW platform description: This OID contains the description of the Software platform. |
| 1.3.6.1.4.1.20044.114.7.6 | Scalarpmoac20ilRinvGwPlatform | read-only | current | GW platform description: This OID contains the description of the gateware platform. |
| 1.3.6.1.4.1.20044.114.7.7 | Tablepmoac20ilRinvBoosterTable | not-accessible | current | List of the Boosters on the selected module |
| 1.3.6.1.4.1.20044.114.7.7.1 | Rowpmoac20ilRinvBoosterEntry | not-accessible | current | Row definition for the Boosters table |
| 1.3.6.1.4.1.20044.114.7.7.1.1 | Columnpmoac20ilRinvBoosterIndex | read-only | current | Index for Booster table |
| 1.3.6.1.4.1.20044.114.7.7.1.2 | Columnpmoac20ilRinvBooster | read-only | current | Inventory for the Booster: This OID contains the inventory for the Booster |
| 1.3.6.1.4.1.20044.114.7.8 | Tablepmoac20ilRinvPreAmpTable | not-accessible | current | List of the PreAmps on the selected module |
| 1.3.6.1.4.1.20044.114.7.8.1 | Rowpmoac20ilRinvPreAmpEntry | not-accessible | current | Row definition for the PreAmp table |
| 1.3.6.1.4.1.20044.114.7.8.1.1 | Columnpmoac20ilRinvPreAmpIndex | read-only | current | Index for PreAmp table |
| 1.3.6.1.4.1.20044.114.7.8.1.2 | Columnpmoac20ilRinvPreAmp | read-only | current | Inventory for the PreAmp: This OID contains the inventory for the PreAmp |
| 1.3.6.1.4.1.20044.114.9 | Nodepmoac20ilConfig | |||
| 1.3.6.1.4.1.20044.114.9.1 | Nodepmoac20ilCfgNoValue | |||
| 1.3.6.1.4.1.20044.114.9.1.1 | Nodepmoac20iltableclientStartup | |||
| 1.3.6.1.4.1.20044.114.9.1.1.2 | Scalarpmoac20ilCfgclientEdfaLaserCtrl | read-write | current | Default Settings on Client Laser :This OID configures the default initialisation settings on the client laser. |
| 1.3.6.1.4.1.20044.114.9.1.1.3 | Scalarpmoac20ilCfgclientEdfaLaserMode | read-write | current | Default Settings on Client mode :This OID configures the default mode on the client amplifier. |
| 1.3.6.1.4.1.20044.114.9.1.1.4 | Scalarpmoac20ilCfgclientGainValue | read-write | current | Default Settings on Client Gain :This OID configures the default gain on the client amplifier. |
| 1.3.6.1.4.1.20044.114.9.1.1.5 | Scalarpmoac20ilCfgclientTiltValue | read-write | current | Default Settings on Client Tilt :This OID configures the default tilt on the client amplifier. |
| 1.3.6.1.4.1.20044.114.9.1.1.6 | Scalarpmoac20ilCfgclientMsaLoss | read-write | current | Default Settings on Client MSA :This OID configures the default MSA value on the client amplifier. |
| 1.3.6.1.4.1.20044.114.9.1.1.7 | Scalarpmoac20ilCfgclientOutputPowerValue | read-write | current | Default Settings on Client Output power :This OID configures the default Output power value on the client amplifier. |
| 1.3.6.1.4.1.20044.114.9.1.1.8 | Scalarpmoac20ilCfgclientAseCompensation | read-write | current | Default Settings on Client ASE :This OID configures the default ASE compensation value on the client amplifier. |
| 1.3.6.1.4.1.20044.114.9.1.1.10 | Scalarpmoac20ilCfgclientGainHighAlarm | read-write | current | Default setting on Gain High Alarm :This register configures the default initialisation settings on the alarm threshold |
| 1.3.6.1.4.1.20044.114.9.1.1.11 | Scalarpmoac20ilCfgclientGainHighWarning | read-write | current | Default setting on Gain High Warning :This register configures the default initialisation settings on the warning threshold |
| 1.3.6.1.4.1.20044.114.9.1.1.12 | Scalarpmoac20ilCfgclientGainLowWarning | read-write | current | Default setting on Gain Low Warning :This register configures the default initialisation settings on the warning threshold |
| 1.3.6.1.4.1.20044.114.9.1.1.13 | Scalarpmoac20ilCfgclientGainLowAlarm | read-write | current | Default setting on Gain Low Alarm :This register configures the default initialisation settings on the alarm threshold |
| 1.3.6.1.4.1.20044.114.9.1.1.14 | Scalarpmoac20ilCfgclientLossOfSignal | read-write | current | Default setting on Loss Of Signal :This register configures the default initialisation settings on the Loss Of Signal threshold |
| 1.3.6.1.4.1.20044.114.9.2 | Nodepmoac20ilCfgLineStartUp | |||
| 1.3.6.1.4.1.20044.114.9.2.1 | Nodepmoac20iltablelineStartup | |||
| 1.3.6.1.4.1.20044.114.9.2.1.2 | Scalarpmoac20ilCfglineEdfaLaserCtrl | read-write | current | Default Settings on Line Laser :This OID configures the default initialisation settings on the line laser. |
| 1.3.6.1.4.1.20044.114.9.2.1.3 | Scalarpmoac20ilCfglineEdfaLaserMode | read-write | current | Default Settings on Line mode :This OID configures the default mode on the line amplifier. |
| 1.3.6.1.4.1.20044.114.9.2.1.4 | Scalarpmoac20ilCfglineGainValue | read-write | current | Default Settings on Line Gain :This OID configures the default gain on the line amplifier. |
| 1.3.6.1.4.1.20044.114.9.2.1.5 | Scalarpmoac20ilCfglineTiltValue | read-write | current | Default Settings on Line Tilt :This OID configures the default tilt on the line amplifier. |
| 1.3.6.1.4.1.20044.114.9.2.1.6 | Scalarpmoac20ilCfglineMsaLoss | read-write | current | Default Settings on Line MSA :This OID configures the default MSA value on the line amplifier. |
| 1.3.6.1.4.1.20044.114.9.2.1.7 | Scalarpmoac20ilCfglineOutputPowerValue | read-write | current | Default Settings on Line Output power :This OID configures the default Output power value on the line amplifier. |
| 1.3.6.1.4.1.20044.114.9.2.1.8 | Scalarpmoac20ilCfglineAseCompensation | read-write | current | Default Settings on Line ASE :This OID configures the default ASE compensation value on the line amplifier. |
| 1.3.6.1.4.1.20044.114.9.2.1.10 | Scalarpmoac20ilCfglineGainHighAlarm | read-write | current | Default setting on Gain High Alarm :This register configures the default initialisation settings on the alarm threshold |
| 1.3.6.1.4.1.20044.114.9.2.1.11 | Scalarpmoac20ilCfglineGainHighWarning | read-write | current | Default setting on Gain High Warning :This register configures the default initialisation settings on the warning threshold |
| 1.3.6.1.4.1.20044.114.9.2.1.12 | Scalarpmoac20ilCfglineGainLowWarning | read-write | current | Default setting on Gain Low Warning :This register configures the default initialisation settings on the warning threshold |
| 1.3.6.1.4.1.20044.114.9.2.1.13 | Scalarpmoac20ilCfglineGainLowAlarm | read-write | current | Default setting on Gain Low Alarm :This register configures the default initialisation settings on the alarm threshold |
| 1.3.6.1.4.1.20044.114.9.2.1.14 | Scalarpmoac20ilCfglineLossOfSignal | read-write | current | Default setting on Loss Of Signal :This register configures the default initialisation settings on the Loss Of Signal threshold |
| 1.3.6.1.4.1.20044.114.9.2.1.18 | Scalarpmoac20ilCfglossEnable | read-write | current | Default setting on Loss Of Signal :This register configures the default initialisation settings on the Loss Of Signal |
| 1.3.6.1.4.1.20044.114.9.3 | Nodepmoac20ilCfgClientSupvStartUp | |||
| 1.3.6.1.4.1.20044.114.9.3.1 | Tablepmoac20ilCfgLineStartupTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.114.9.3.1.1 | Rowpmoac20ilCfgLineStartupEntry | not-accessible | current | Row definition for the clientSupvStartUp table |
| 1.3.6.1.4.1.20044.114.9.3.1.1.1 | Columnpmoac20ilCfgLineStartupIndex | read-only | current | Index definition for the lineStartup table |
| 1.3.6.1.4.1.20044.114.9.3.1.1.3 | Columnpmoac20ilCfgLineOscLaserCtrlPortn | read-write | current | Default Settings on OSC Laser :This OID configures the default initialisation settings on the OSC |
| 1.3.6.1.4.1.20044.114.9.3.1.1.4 | Columnpmoac20ilCfgLineOscOosPortn | read-write | current | Default Settings on OSC mode :This OID configures the default mode on the OSC |
| 1.3.6.1.4.1.20044.114.9.3.1.1.5 | Columnpmoac20ilCfgLineOscSpanLengthPortn | read-write | current | Default Settings on OSC span length :This OID defines the length of the span connected on the OSC port |
| 1.3.6.1.4.1.20044.114.9.3.1.1.6 | Columnpmoac20ilCfgLineOscCorrectionFactorPortn | read-write | current | Default Settings on OSC attenuation corrector factor :This OID defines the correction factor to apply on the span attenuation measure on the OSC Channel (1510)… |
| 1.3.6.1.4.1.20044.114.9.3.1.1.11 | Columnpmoac20ilCfgLineSpanLossHighAlarmPortn | read-write | current | Default setting on Span Loss High Alarm :This register configures the default initialisation settings on the alarm threshold |
| 1.3.6.1.4.1.20044.114.9.3.1.1.12 | Columnpmoac20ilCfgLineSpanLossHighWarningPortn | read-write | current | Default setting on Span Loss High Warning :This register configures the default initialisation settings on the warning threshold |
| 1.3.6.1.4.1.20044.114.9.3.1.1.13 | Columnpmoac20ilCfgLineSpanLossLowWarningPortn | read-write | current | Default setting on Span Loss Low Warning :This register configures the default initialisation settings on the warning threshold |
| 1.3.6.1.4.1.20044.114.9.3.1.1.14 | Columnpmoac20ilCfgLineSpanLossLowAlarmPortn | read-write | current | Default setting on Span Loss Low Alarm :This register configures the default initialisation settings on the alarm threshold |
| 1.3.6.1.4.1.20044.114.9.4 | Nodepmoac20ilCfgLabels | |||
| 1.3.6.1.4.1.20044.114.9.4.1 | Tablepmoac20ilCfgLabelclientTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.114.9.4.1.1 | Rowpmoac20ilCfgLabelclientEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.114.9.4.1.1.1 | Columnpmoac20ilCfgLabelclientIndex | read-only | current | Index definition for the labelclient table |
| 1.3.6.1.4.1.20044.114.9.4.1.1.3 | Columnpmoac20ilCfgLabelclientPortn | read-write | current | Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. |
| 1.3.6.1.4.1.20044.114.9.4.2 | Tablepmoac20ilCfgLabellineTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.114.9.4.2.1 | Rowpmoac20ilCfgLabellineEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.114.9.4.2.1.1 | Columnpmoac20ilCfgLabellineIndex | read-only | current | Index definition for the labelline table |
| 1.3.6.1.4.1.20044.114.9.4.2.1.3 | Columnpmoac20ilCfgLabellinePortn | read-write | current | Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. |
| 1.3.6.1.4.1.20044.114.9.257 | Scalarpmoac20ilCfgWriteConfiguration | read-write | current | Write configuration to module:This OID writes the complete configuration to the module |
| 1.3.6.1.4.1.20044.114.10 | Nodepmoac20iltraps | |||
| 1.3.6.1.4.1.20044.114.10.4 | Scalarpmoac20iltrapBoardNumber | read-only | current | Last module which generates a trap |
| 1.3.6.1.4.1.20044.114.10.34 | Notificationpmoac20ilLineTrapCritGoesOn | current | Critical Line default is activated | |
| 1.3.6.1.4.1.20044.114.10.35 | Notificationpmoac20ilLineTrapCritGoesOff | current | Critical Line default disappeared | |
| 1.3.6.1.4.1.20044.114.10.44 | Notificationpmoac20ilClientTrapCritGoesOn | current | Critical client default is activated | |
| 1.3.6.1.4.1.20044.114.10.45 | Notificationpmoac20ilClientTrapCritGoesOff | current | Critical client default disappeared | |
| 1.3.6.1.4.1.20044.114.10.50 | Notificationpmoac20ilPowerTrapUrgentGoesOn | current | Urgent power supply default is activated | |
| 1.3.6.1.4.1.20044.114.10.51 | Notificationpmoac20ilPowerTrapUrgentGoesOff | current | Urgent power supply default disappeared |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| Pmoac20ilaprMode | INTEGER { pmoac20ilaproffmode(0), pmoac20ilaprsemiautomode(1), pmoac20ilaprautomode(2) pmoac20ilaprlossforwardingmode(3) pmoac20ilaprrepeatmode(4) } | current | Different modes on APR |
| Pmoac20ilBoosterCstGainAdjMode | INTEGER { pmoac20ilboostercstgainadjsemiautomode(1), pmoac20ilboostercstgainadjautomode(2) } | current | Different modes when constant Gain |
| Pmoac20ilBoosterGainAdjMode | INTEGER { pmoac20ilboostergainadjmanualmode(0), pmoac20ilboostergainadjsemiautomode(1), pmoac20ilboostergainadjautomode(2) } | current | Different modes on Gain |
| Pmoac20ilboosterMode | INTEGER { pmoac20ilboosterdefaultmode(0), pmoac20ilboosterconstantcurrentmode(1), pmoac20ilboosterconstantpowermode(2) pmoac20ilboosterconstantgainmode(3) pmoac20ilboosterpoutpinmode(4) pmoac20ilboostermanualmode(5) pmoac20ilboosterfeedforwardmode(6) pmoac20ilboostertransientsupmode(7) } | current | Different modes on OA booster |
| Pmoac20ilPreAmpCstGainAdjMode | INTEGER { pmoac20ilpreampcstgainadjsemiautomode(1), pmoac20ilpreampcstgainadjautomode(2) } | current | Different modes when constant Gain |
| Pmoac20ilPreAmpGainAdjMode | INTEGER { pmoac20ilpreampgainadjmanualmode(0), pmoac20ilpreampgainadjsemiautomode(1), pmoac20ilpreampgainadjautomode(2) } | current | Different modes on Gain |
| Pmoac20ilpreampMode | INTEGER { pmoac20ilpreampdefaultmode(0), pmoac20ilpreampconstantcurrentmode(1), pmoac20ilpreampconstantpowermode(2) pmoac20ilpreampconstantgainmode(3) pmoac20ilpreamppoutpinmode(4) pmoac20ilpreampmanualmode(5) pmoac20ilpreampfeedforwardmode(6) pmoac20ilpreamptransientsupmode(7) } | current | Different modes on OA preamp |