OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.114Identitymodulepmoac20ilCreation
1.3.6.1.4.1.20044.114.2Nodepmoac20ilalarms
1.3.6.1.4.1.20044.114.2.1Nodepmoac20ilAlmOther
1.3.6.1.4.1.20044.114.2.1.1Nodepmoac20ilAlmOtherNurg
1.3.6.1.4.1.20044.114.2.1.1.2Nodepmoac20ilAlmsynthAlm2
1.3.6.1.4.1.20044.114.2.1.1.2.1Scalarpmoac20ilAlmConfTableSaveread-onlycurrentPM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> other…
1.3.6.1.4.1.20044.114.2.1.1.2.2Scalarpmoac20ilAlmInvUploadread-onlycurrentInventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> other (1) <Alarmtype> other (1) <Polarit…
1.3.6.1.4.1.20044.114.2.1.1.2.3Scalarpmoac20ilAlmConfTableLoadread-onlycurrentPM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> other (1) <Alarmt…
1.3.6.1.4.1.20044.114.2.1.1.75Nodepmoac20ilAlmfoaWarnings
1.3.6.1.4.1.20044.114.2.1.1.75.7Scalarpmoac20ilAlmTermpLowWarningread-onlycurrentTemperature Low Warning :This OID indicates that the PM temperature if lower than the Warning threshold <Condtype> TERMP_LOW_WARNING <Probcause> temperatureUna…
1.3.6.1.4.1.20044.114.2.1.1.75.8Scalarpmoac20ilAlmTempHighWarningread-onlycurrentTemperature High Warning :This OID indicates that the PM temperature if higher than the Warning threshold <Condtype> TEMP_HIGH_WARNING <Probcause> temperatureU…
1.3.6.1.4.1.20044.114.2.1.2Nodepmoac20ilAlmOtherUrg
1.3.6.1.4.1.20044.114.2.1.2.74Nodepmoac20ilAlmfoaAlarms
1.3.6.1.4.1.20044.114.2.1.2.74.7Scalarpmoac20ilAlmTermpLowAlarmread-onlycurrentTemperature Low Alarm :This OID indicates that the PM temperature if lower than the alarm threshold <Condtype> TERMP_LOW_ALARM <Probcause> temperatureUnaccepta…
1.3.6.1.4.1.20044.114.2.1.2.74.8Scalarpmoac20ilAlmTempHighAlarmread-onlycurrentTemperature High Alarm :This OID indicates that the PM temperature is higher than the alarm threshold <Condtype> TEMP_HIGH_ALARM <Probcause> temperatureUnaccep…
1.3.6.1.4.1.20044.114.2.1.3Nodepmoac20ilAlmOtherCrit
1.3.6.1.4.1.20044.114.2.1.3.0Nodepmoac20ilAlmsynthAlm0
1.3.6.1.4.1.20044.114.2.1.3.0.1Scalarpmoac20ilAlmMaintenanceModeread-onlycurrentMaintenance Mode :This OID indicates that the PM is in maintenance mode <Help> This status indiates if the module is currently in maintenance mode <Condtype> M…
1.3.6.1.4.1.20044.114.2.1.3.0.2Scalarpmoac20ilAlmAprOnread-onlycurrentAutomatic Power Reduction :This OID indicates that the APR algorithm has been operated and the output of the lasers are shutdown <Help> The APR algorithm has b…
1.3.6.1.4.1.20044.114.2.1.3.0.9Scalarpmoac20ilAlmModGlobFailread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the PM <Condtype> MOD_GLOB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> sy…
1.3.6.1.4.1.20044.114.2.1.3.0.10Scalarpmoac20ilAlmUpEdfaInitNotComplread-onlycurrentIL1 Not Initialized :This OID indicates that the initialisation of the IL1 is not completed <Help> This status indicates if the IL1 has been correctly initiali…
1.3.6.1.4.1.20044.114.2.1.3.0.11Scalarpmoac20ilAlmDwEdfaInitNotComplread-onlycurrentIL2 Not Initialized :This OID indicates that the initialisation of the IL2 is not completed <Help> This status indicates if the IL2 has been correctly initiali…
1.3.6.1.4.1.20044.114.2.1.3.0.12Scalarpmoac20ilAlmExtPump1NotLockedread-onlycurrentExternal Pump Not Detected :This OID indicates that the first external pump is not detected by the amplifier module <Help> This alarm indicates if the external…
1.3.6.1.4.1.20044.114.2.1.3.0.15Scalarpmoac20ilAlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.114.2.1.3.0.16Scalarpmoac20ilAlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.114.2.2Nodepmoac20ilAlmClient
1.3.6.1.4.1.20044.114.2.2.1Nodepmoac20ilAlmClientNurg
1.3.6.1.4.1.20044.114.2.2.1.33Nodepmoac20ilAlmclientEdfaWarnings
1.3.6.1.4.1.20044.114.2.2.1.33.1Scalarpmoac20ilAlmClientGainLowWarningread-onlycurrentIL2 Gain Low Warning :This OID indicates that the Gain is lower than the Warning threshold of the IL2 Module <Help> This alarm indicates if the IL2 gain is too…
1.3.6.1.4.1.20044.114.2.2.1.33.2Scalarpmoac20ilAlmClientGainHighWarningread-onlycurrentIL2 Gain High Warning :This OID indicates that the Gain is higher than the Warning threshold of the IL2 Module <Help> This alarm indicates if the IL2 gain is t…
1.3.6.1.4.1.20044.114.2.2.1.33.3Scalarpmoac20ilAlmClientInputPwrLowWarningread-onlycurrentIL2 Rx Pwr Low Warning :This OID indicates that the Receive Power is lower than the Warning threshold of the IL2 Optical Module <Help> This warning indicates i…
1.3.6.1.4.1.20044.114.2.2.1.33.4Scalarpmoac20ilAlmClientInputPwrHighWarningread-onlycurrentIL2 Rx Pwr High Warning :This OID indicates that the Receive Power is higher than the Warning threshold of the IL2 Optical Module <Help> This warning indicates…
1.3.6.1.4.1.20044.114.2.2.1.33.5Scalarpmoac20ilAlmClientOutputPwrLowWarningread-onlycurrentIL2 Tx Pwr Low Warning :This OID indicates that the Transmit Power is lower than the Warning threshold of the IL2 Optical Module <Help> This warning indicates …
1.3.6.1.4.1.20044.114.2.2.1.33.6Scalarpmoac20ilAlmClientOutputPwrHighWarningread-onlycurrentIL2 Tx Pwr High Warning :This OID indicates that the Transmit Power is higher than the Warning threshold of the IL2 Optical Module <Help> This warning indicate…
1.3.6.1.4.1.20044.114.2.2.1.33.7Scalarpmoac20ilAlmClientBiasLowWarningread-onlycurrentIL2 Bias Low Warning :This OID indicates that the Bias is lower than the Warning threshold of the IL2 Optical Module <Help> This warning indicates if the IL2 b…
1.3.6.1.4.1.20044.114.2.2.1.33.8Scalarpmoac20ilAlmClientBiasHighWarningread-onlycurrentIL2 Bias High Warning :This OID indicates that the Bias is higher than the Warning threshold of the IL2 Optical Module <Help> This warning indicates if the IL2…
1.3.6.1.4.1.20044.114.2.2.2Nodepmoac20ilAlmClientUrg
1.3.6.1.4.1.20044.114.2.2.2.32Nodepmoac20ilAlmclientEdfaAlarms1
1.3.6.1.4.1.20044.114.2.2.2.32.1Scalarpmoac20ilAlmClientGainLowAlarmread-onlycurrentIL2 Gain Low Alarm :This OID indicates that the Gain is lower than the alarm threshold of the IL2 Module <Help> This alarm indicates if the IL2 gain is too low…
1.3.6.1.4.1.20044.114.2.2.2.32.2Scalarpmoac20ilAlmClientGainHighAlarmread-onlycurrentIL2 Gain High Alarm :This OID indicates that the Gain is higher than the alarm threshold of the IL2 Module <Help> This alarm indicates if the IL2 gain is too h…
1.3.6.1.4.1.20044.114.2.2.2.32.3Scalarpmoac20ilAlmClientInputPwrLowAlarmread-onlycurrentIL2 Rx Pwr Low Alarm :This OID indicates that the Receive Power is lower than the alarm threshold of the IL2 Optical Module <Help> This alarm indicates if the …
1.3.6.1.4.1.20044.114.2.2.2.32.4Scalarpmoac20ilAlmClientInputPwrHighAlarmread-onlycurrentIL2 Rx Pwr High Alarm :This OID indicates that the Receive Power is higher than the alarm threshold of the IL2 Optical Module <Help> This alarm indicates if th…
1.3.6.1.4.1.20044.114.2.2.2.32.5Scalarpmoac20ilAlmClientOutputPwrLowAlarmread-onlycurrentIL2 Tx Pwr Low Alarm :This OID indicates that the Transmit Power is lower than the alarm threshold of the IL2 Optical Module <Help> This alarm indicates if the…
1.3.6.1.4.1.20044.114.2.2.2.32.6Scalarpmoac20ilAlmClientOutputPwrHighAlarmread-onlycurrentIL2 Tx Pwr High Alarm :This OID indicates that the Transmit Power is higher than the alarm threshold of the IL2 Optical Module <Help> This alarm indicates if t…
1.3.6.1.4.1.20044.114.2.2.2.32.7Scalarpmoac20ilAlmClientBiasLowAlarmread-onlycurrentIL2 Bias Low Alarm :This OID indicates that the Bias is lower than the alarm threshold of the IL2 Optical Module <Help> This alarm indicates if the IL2 bias is…
1.3.6.1.4.1.20044.114.2.2.2.32.8Scalarpmoac20ilAlmClientBiasHighAlarmread-onlycurrentIL2 Bias High Alarm :This OID indicates that the Bias is higher than the alarm threshold of the IL2 Optical Module <Help> This alarm indicates if the IL2 bias …
1.3.6.1.4.1.20044.114.2.2.3Nodepmoac20ilAlmClientCrit
1.3.6.1.4.1.20044.114.2.2.3.8Nodepmoac20ilAlmsynthAlm8
1.3.6.1.4.1.20044.114.2.2.3.8.4Scalarpmoac20ilAlmClientHwFailread-onlycurrentClient Port HW Failure :This OID indicates a failure on Client port, most probably caused by a HW issue <Condtype> CLIENT_HW_FAIL <Probcause> equipmentMalfunct…
1.3.6.1.4.1.20044.114.2.2.3.8.5Scalarpmoac20ilAlmClientTxOffread-onlycurrentIL2 Optical Output Shutdown :This OID indicates the IL2 optical output power is on <Help> This status indicates if the IL2 laser pump transceiver laser is ON o…
1.3.6.1.4.1.20044.114.2.2.3.8.9Scalarpmoac20ilAlmClientDdmWarningread-onlycurrentWarning On IL2 DDM :This OID indicates a warning is present coming out of the IL2 DDM <Help> This alarm indicates if a DDM Warning has been detected on the IL2…
1.3.6.1.4.1.20044.114.2.2.3.8.10Scalarpmoac20ilAlmClientDdmAlmread-onlycurrentAlarm On IL2 DDM :This OID indicates an alarm is present coming out of the Pre_Amp DDM <Help> This alarm indicates if a DDM Alarm has been detected on the IL2 …
1.3.6.1.4.1.20044.114.2.2.3.8.12Scalarpmoac20ilAlmClientFailread-onlycurrentClient Port Failure :This OID indicates a failure on the Client port <Condtype> CLIENT_FAIL <Probcause> bandwidthReduced(4) <Alarmtype> synthesisAlarm (12) <Po…
1.3.6.1.4.1.20044.114.2.2.3.8.13Scalarpmoac20ilAlmClientExtPumpFailread-onlycurrentIL2 External Pump Fail :This OID indicates that the external pump linked to the IL2 is in fail condition <Help> This alarm indicates if the external pump linke…
1.3.6.1.4.1.20044.114.2.2.3.8.14Scalarpmoac20ilAlmSupvbFailread-onlycurrent: <Condtype> SUPVB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> equipmentAlarm (5) <Polarity> (2)
1.3.6.1.4.1.20044.114.2.2.3.35Nodepmoac20ilAlmclientEdfaAlarms2
1.3.6.1.4.1.20044.114.2.2.3.35.1Scalarpmoac20ilAlmClientEdfaNrread-onlycurrentIL2 Optical Module Not Ready :This OID indicates that the IL2 Optical Module is not ready <Help> This status indicates if the IL2 has been correctly initialize…
1.3.6.1.4.1.20044.114.2.2.3.35.2Scalarpmoac20ilAlmClientEdfaTecFailread-onlycurrentIL2 TEC Fail :This OID indicates that the TEC is in fail condition on the IL2 Optical Module <Help> This alarm indicates if the TEC of the IL2 is in fail condi…
1.3.6.1.4.1.20044.114.2.2.3.35.3Scalarpmoac20ilAlmClientEdfaLaserFailread-onlycurrentIL2 Pump Laser Fail :This OID indicates a Transmit Laser Fail on the IL2 Optical Module <Help> This alarm indicates if the laser of the IL2 is in fail conditio…
1.3.6.1.4.1.20044.114.2.2.3.35.4Scalarpmoac20ilAlmClientEdfaLosread-onlycurrentIL2 Loss Of Signal :This OID indicates a Loss of Signal on the IL2 Optical Module <Help> This alarm indicates if an optical signal is detected on the IL2 input…
1.3.6.1.4.1.20044.114.2.2.3.35.5Scalarpmoac20ilAlmClientExtPumpEdfaLowCurrentread-onlycurrentIL2 Pump Low Current :This OID indicates that the EDFA pump current of IL2 is too low because of the external pump high power<Help> This alarm (only active whe…
1.3.6.1.4.1.20044.114.2.2.3.35.6Scalarpmoac20ilAlmClientGainOutOfRangeread-onlycurrentIL2 Gain Out Of Range :This OID indicates the target gain of the IL2 is out of range (18-32dB), the flatness of the IL1 is not guaranteed.<Help> This alarm ind…
1.3.6.1.4.1.20044.114.2.2.3.37Nodepmoac20ilAlmclientMsaAlarms
1.3.6.1.4.1.20044.114.2.2.3.37.1Scalarpmoac20ilAlmClientMsaLosread-onlycurrentIL2 MSA Loss Of Signal :This OID indicates a Loss of Signal is detected on the Mid Stage Access of the IL2 EDFAThis alarm indicates a Loss of Signal is detecte…
1.3.6.1.4.1.20044.114.2.2.3.37.2Scalarpmoac20ilAlmClientMsaAttenuationread-onlycurrentIL2 MSA Attenuation Alarm :This OID indicates the attenuation on the IL2 Mid Stage access has changed.This alarm indicates the attenuation on the IL2 Mid Stage…
1.3.6.1.4.1.20044.114.2.3Nodepmoac20ilAlmLine
1.3.6.1.4.1.20044.114.2.3.1Nodepmoac20ilAlmLineNurg
1.3.6.1.4.1.20044.114.2.3.1.41Nodepmoac20ilAlmlineEdfaWarnings
1.3.6.1.4.1.20044.114.2.3.1.41.1Scalarpmoac20ilAlmLineGainLowWarningread-onlycurrentIL1 Gain Low Warning :This OID indicates that the Gain is lower than the Warning threshold of the IL1 Module <Help> This alarm indicates if the IL1 gain is too…
1.3.6.1.4.1.20044.114.2.3.1.41.2Scalarpmoac20ilAlmLineGainHighWarningread-onlycurrentIL1 Gain High Warning :This OID indicates that the Gain is higher than the Warning threshold of the IL1 Module <Help> This alarm indicates if the IL1 gain is t…
1.3.6.1.4.1.20044.114.2.3.1.41.3Scalarpmoac20ilAlmLineInputPwrLowWarningread-onlycurrentIL1 Rx Pwr Low Warning :This OID indicates that the Receive Power is lower than the Warning threshold of the IL1 Optical Module <Help> This warning indicates i…
1.3.6.1.4.1.20044.114.2.3.1.41.4Scalarpmoac20ilAlmLineInputPwrHighWarningread-onlycurrentIL1 Rx Pwr High Warning :This OID indicates that the Receive Power is higher than the Warning threshold of the IL1 Optical Module <Help> This warning indicates…
1.3.6.1.4.1.20044.114.2.3.1.41.5Scalarpmoac20ilAlmLineOutputPwrLowWarningread-onlycurrentIL1 Tx Pwr Low Warning :This OID indicates that the Transmit Power is lower than the Warning threshold of the IL1 Optical Module <Help> This warning indicates …
1.3.6.1.4.1.20044.114.2.3.1.41.6Scalarpmoac20ilAlmLineOutputPwrHighWarningread-onlycurrentIL1 Tx Pwr High Warning :This OID indicates that the Transmit Power is higher than the Warning threshold of the IL1 Optical Module <Help> This warning indicate…
1.3.6.1.4.1.20044.114.2.3.1.41.7Scalarpmoac20ilAlmLineBiasLowWarningread-onlycurrentIL1 Bias Low Warning :This OID indicates that the Bias is lower than the Warning threshold of the IL1 Optical Module <Help> This warning indicates if the IL1 b…
1.3.6.1.4.1.20044.114.2.3.1.41.8Scalarpmoac20ilAlmLineBiasHighWarningread-onlycurrentIL1 Bias High Warning :This OID indicates that the Bias is higher than the Warning threshold of the IL1 Optical Module <Help> This warning indicates if the IL1…
1.3.6.1.4.1.20044.114.2.3.2Nodepmoac20ilAlmLineUrg
1.3.6.1.4.1.20044.114.2.3.2.40Nodepmoac20ilAlmlineEdfaAlarms1
1.3.6.1.4.1.20044.114.2.3.2.40.1Scalarpmoac20ilAlmLineGainLowAlarmread-onlycurrentIL1 Gain Low Alarm :This OID indicates that the Gain is lower than the alarm threshold of the IL1 Module <Help> This alarm indicates if the IL1 gain is too low…
1.3.6.1.4.1.20044.114.2.3.2.40.2Scalarpmoac20ilAlmLineGainHighAlarmread-onlycurrentIL1 Gain High Alarm :This OID indicates that the Gain is higher than the alarm threshold of the IL1 Module <Help> This alarm indicates if the IL1 gain is too h…
1.3.6.1.4.1.20044.114.2.3.2.40.3Scalarpmoac20ilAlmLineInputPwrLowAlarmread-onlycurrentIL1 Rx Pwr Low Alarm :This OID indicates that the Receive Power is lower than the alarm threshold of the IL1 Optical Module <Help> This alarm indicates if the …
1.3.6.1.4.1.20044.114.2.3.2.40.4Scalarpmoac20ilAlmLineInputPwrHighAlarmread-onlycurrentIL1 Rx Pwr High Alarm :This OID indicates that the Receive Power is higher than the alarm threshold of the IL1 Optical Module <Help> This alarm indicates if th…
1.3.6.1.4.1.20044.114.2.3.2.40.5Scalarpmoac20ilAlmLineOutputPwrLowAlarmread-onlycurrentIL1 Tx Pwr Low Alarm :This OID indicates that the Transmit Power is lower than the alarm threshold of the IL1 Optical Module <Help> This alarm indicates if the…
1.3.6.1.4.1.20044.114.2.3.2.40.6Scalarpmoac20ilAlmLineOutputPwrHighAlarmread-onlycurrentIL1 Tx Pwr High Alarm :This OID indicates that the Transmit Power is higher than the alarm threshold of the IL1 Optical Module <Help> This alarm indicates if t…
1.3.6.1.4.1.20044.114.2.3.2.40.7Scalarpmoac20ilAlmLineBiasLowAlarmread-onlycurrentIL1 Bias Low Alarm :This OID indicates that the Bias is lower than the alarm threshold of the IL1 Optical Module <Help> This alarm indicates if the IL1 bias is…
1.3.6.1.4.1.20044.114.2.3.2.40.8Scalarpmoac20ilAlmLineBiasHighAlarmread-onlycurrentIL1 Bias High Alarm :This OID indicates that the Bias is higher than the alarm threshold of the IL1 Optical Module <Help> This alarm indicates if the IL1 bias …
1.3.6.1.4.1.20044.114.2.3.3Nodepmoac20ilAlmLineCrit
1.3.6.1.4.1.20044.114.2.3.3.7Nodepmoac20ilAlmsynthAlm7
1.3.6.1.4.1.20044.114.2.3.3.7.4Scalarpmoac20ilAlmLineHwFailread-onlycurrentLine Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Condtype> LINE_HW_FAIL <Probcause> equipmentMalfunction (1…
1.3.6.1.4.1.20044.114.2.3.3.7.5Scalarpmoac20ilAlmLineTxOffread-onlycurrentIL1 Optical Output Shutdown :This OID indicates the IL1 optical output power is on <Help> This status indicates if the IL1 laser pump is ON or OFF <Condtype> L…
1.3.6.1.4.1.20044.114.2.3.3.7.9Scalarpmoac20ilAlmLineDdmWarningread-onlycurrentWarning On IL1 DDM :This OID indicates a warning is present coming out of the IL1 DDM <Help> This alarm indicates if a DDM Warning has been detected on the IL1…
1.3.6.1.4.1.20044.114.2.3.3.7.10Scalarpmoac20ilAlmLineDdmAlmread-onlycurrentAlarm On IL1 DDM :This OID indicates an alarm is present coming out of the IL1 DDM <Help> This alarm indicates if a DDM Alarm has been detected on the IL1 <Con…
1.3.6.1.4.1.20044.114.2.3.3.7.12Scalarpmoac20ilAlmLineFailread-onlycurrentLine Port Failure :This OID indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> callEstablishmentError(5) <Alarmtype> synthesisAlarm (12) <Po…
1.3.6.1.4.1.20044.114.2.3.3.7.13Scalarpmoac20ilAlmLineExtPumpFailread-onlycurrentIL1 External Pump Fail :This OID indicates that the external pump linked to the IL1 is in fail condition <Help> This alarm indicates if the external pump linke…
1.3.6.1.4.1.20044.114.2.3.3.7.14Scalarpmoac20ilAlmSupvaFailread-onlycurrent: <Condtype> SUPVA_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> equipmentAlarm (5) <Polarity> (2)
1.3.6.1.4.1.20044.114.2.3.3.43Nodepmoac20ilAlmlineEdfaAlarms2
1.3.6.1.4.1.20044.114.2.3.3.43.1Scalarpmoac20ilAlmLineEdfaNrread-onlycurrentIL1 Optical Module Not Ready :This OID indicates that the IL1 Optical Module is not ready <Help> This status indicates if the IL1 has been correctly initialize…
1.3.6.1.4.1.20044.114.2.3.3.43.2Scalarpmoac20ilAlmLineEdfaTecFailread-onlycurrentIL1 TEC Fail :This OID indicates that the TEC is in fail condition on the IL1 Optical Module <Help> This alarm indicates if the TEC of the IL1 is in fail condi…
1.3.6.1.4.1.20044.114.2.3.3.43.3Scalarpmoac20ilAlmLineEdfaLaserFailread-onlycurrentIL1 Pump Laser Fail :This OID indicates a Transmit Laser Fail on the IL1 Optical Module <Help> This alarm indicates if the laser of the IL1 is in fail conditio…
1.3.6.1.4.1.20044.114.2.3.3.43.4Scalarpmoac20ilAlmLineEdfaLosread-onlycurrentIL1 Loss Of Signal :This OID indicates a Loss of Signal on the IL1 Optical Module <Help> This alarm indicates if an optical signal is detected on the IL1 input…
1.3.6.1.4.1.20044.114.2.3.3.43.5Scalarpmoac20ilAlmLineExtPumpEdfaLowCurrentread-onlycurrentIL1 Pump Low Current :This OID indicates that the EDFA pump current of IL1 is too low because of the external pump high power<Help> This alarm (only active whe…
1.3.6.1.4.1.20044.114.2.3.3.43.6Scalarpmoac20ilAlmLineGainOutOfRangeread-onlycurrentIL1 Gain Out Of Range :This OID indicates the target gain of the IL1 is out of range (10-18dB), the flatness of the IL1 is not guaranteed.<Help> This alarm ind…
1.3.6.1.4.1.20044.114.2.3.3.45Nodepmoac20ilAlmlineMsaAlarms
1.3.6.1.4.1.20044.114.2.3.3.45.1Scalarpmoac20ilAlmLineMsaLosread-onlycurrentIL1 MSA Loss Of Signal :This OID indicates a Loss of Signal is detected on the Mid Stage Access of the IL1 EDFAThis alarm indicates a Loss of Signal is detecte…
1.3.6.1.4.1.20044.114.2.3.3.45.2Scalarpmoac20ilAlmLineMsaAttenuationread-onlycurrentIL1 MSA Attenuation Alarm :This OID indicates the attenuation on the IL1 Mid Stage access has changed.This alarm indicates the attenuation on the IL2 Mid Stage…
1.3.6.1.4.1.20044.114.2.3.3.48Tablepmoac20ilAlmlineOscAlarmsTablenot-accessiblecurrentList of pmoac20ilAlmlineOscAlarms Article
1.3.6.1.4.1.20044.114.2.3.3.48.1Rowpmoac20ilAlmlineOscAlarmsEntrynot-accessiblecurrentRow definition for the pmoac20ilAlmlineOscAlarms table
1.3.6.1.4.1.20044.114.2.3.3.48.1.1Columnpmoac20ilAlmlineOscAlarmsIndexread-onlycurrentIndex definition for the pmoac20ilAlmlineOscAlarms table
1.3.6.1.4.1.20044.114.2.3.3.48.1.2Columnpmoac20ilAlmLineLosPortnread-onlycurrentOSC Loss Of Signal :This OID indicates that no signal is present on the OSC <Help> This alarms indicates that no signal is present on the OSC <Condtype> LINE_L…
1.3.6.1.4.1.20044.114.2.3.3.48.1.3Columnpmoac20ilAlmLineTxOffPortnread-onlycurrentOSC Optical Output Shutdown :This OID indicates the optical output power is shutdown on OSC<Help> This alarm indicates the optical output power is shutdown on …
1.3.6.1.4.1.20044.114.2.3.3.48.1.4Columnpmoac20ilAlmLineTxFailPortnread-onlycurrentOSC Tx Fail :This OID indicates the OSC Laser is in fail condition<Help> This alarm indicates the OSC Laser is in fail condition <Condtype> LINE_TX_FAIL_1 <Pro…
1.3.6.1.4.1.20044.114.2.3.3.48.1.6Columnpmoac20ilAlmLineOosPortnread-onlycurrentOSC In Service :This OID indicates that the OSC is In Service (1) or Out or Service (2)<Help> This status indicates that the OSC is In Service or Out or Servic…
1.3.6.1.4.1.20044.114.2.3.3.48.1.10Columnpmoac20ilAlmLineWarningPortnread-onlycurrentOSC DDM Warning :This OID indicates a warning is present on OSC Tx power, Receive power or temperature<Help> This alarm indicates a warning is present on OSC T…
1.3.6.1.4.1.20044.114.2.3.3.48.1.11Columnpmoac20ilAlmLineAlmPortnread-onlycurrentOSC DDM Alarm :This alarm indicates an alarm is present on OSC Tx power, Rx power or temperature <Help> This alarm indicates an alarm is present on OSC Tx powe…
1.3.6.1.4.1.20044.114.2.3.3.49Tablepmoac20ilAlmlineOscThresholdAlarmsTablenot-accessiblecurrentList of pmoac20ilAlmlineOscThresholdAlarms Article
1.3.6.1.4.1.20044.114.2.3.3.49.1Rowpmoac20ilAlmlineOscThresholdAlarmsEntrynot-accessiblecurrentRow definition for the pmoac20ilAlmlineOscThresholdAlarms table
1.3.6.1.4.1.20044.114.2.3.3.49.1.1Columnpmoac20ilAlmlineOscThresholdAlarmsIndexread-onlycurrentIndex definition for the pmoac20ilAlmlineOscThresholdAlarms table
1.3.6.1.4.1.20044.114.2.3.3.49.1.2Columnpmoac20ilAlmLineOscTxPwrLowAlarmPortnread-onlycurrentOSC Tx Power Low Alarm :This OID indicates the Tx Power of the OSC is lower than the warning threshold<Help> This alarm indicates the Tx Power of the OSC is lo…
1.3.6.1.4.1.20044.114.2.3.3.49.1.3Columnpmoac20ilAlmLineOscTxPwrHighAlarmPortnread-onlycurrentOSC Tx Power High Alarm :This OID indicates the Tx Power of the OSC is higher than the warning threshold<Help> This alarm indicates the Tx Power of the OSC is …
1.3.6.1.4.1.20044.114.2.3.3.49.1.4Columnpmoac20ilAlmLineOscTxBiasLowAlarmPortnread-onlycurrentOSC Bias Current Low Alarm :This OID indicates the OSC bias current is lower than the alarm threshold <Help> This alarm indicates the OSC bias current is lower…
1.3.6.1.4.1.20044.114.2.3.3.49.1.5Columnpmoac20ilAlmLineOscTxBiasHighAlarmPortnread-onlycurrentOSC Bias Current High Alarm :This OID indicates the OSC bias current is higher than the alarm threshold <Help> This alarm indicates the OSC bias current is hig…
1.3.6.1.4.1.20044.114.2.3.3.49.1.6Columnpmoac20ilAlmLineOscVccLowAlarmPortnread-onlycurrentOSC Vcc Low Alarm :This OID indicates the Vcc of the OSC is lower than the warning threshold<Help> This alarm indicates the Vcc of the OSC is lower than the al…
1.3.6.1.4.1.20044.114.2.3.3.49.1.7Columnpmoac20ilAlmLineOscVccHighAlarmPortnread-onlycurrentOSC Vcc High Alarm :This OID indicates the Vcc of the OSC is higher than the warning threshold<Help> This alarm indicates the Vcc of the OSC is higher than the…
1.3.6.1.4.1.20044.114.2.3.3.49.1.8Columnpmoac20ilAlmLineOscTempLowAlarmPortnread-onlycurrentOSC Temperature Low Alarm :This OID indicates the OSC temperature is lower than the alarm threshold <Help> This alarm indicates the OSC temperature is lower th…
1.3.6.1.4.1.20044.114.2.3.3.49.1.9Columnpmoac20ilAlmLineOscTempHighAlarmPortnread-onlycurrentOSC Temperature High Alarm :This OID indicates the OSC temperature is higher than the alarm threshold <Help> This alarm indicates the OSC temperature is higher…
1.3.6.1.4.1.20044.114.2.3.3.49.1.10Columnpmoac20ilAlmLineOscSpanlossLowAlarmPortnread-onlycurrentOSC Span Loss Low Alarm :This OID indicates the OSC Span Loss is 3dB lower than the span loss reference<Help> This alarm indicates the OSC Span Loss is 3dB low…
1.3.6.1.4.1.20044.114.2.3.3.49.1.11Columnpmoac20ilAlmLineOscSpanlossHighAlarmPortnread-onlycurrentOSC Span Loss High Alarm :This OID indicates the OSC Span Loss is 3dB higher than the span loss reference <Help> This alarm indicates the OSC Span Loss is 3dB …
1.3.6.1.4.1.20044.114.2.3.3.49.1.16Columnpmoac20ilAlmLineOscRxPwrLowAlarmPortnread-onlycurrentOSC Rx Power Low Alarm :This OID indicates the Rx Power of the OSC is lower than the alarm threshold<Help> This alarm indicates the Rx Power of the OSC is lowe…
1.3.6.1.4.1.20044.114.2.3.3.49.1.17Columnpmoac20ilAlmLineOscRxPwrHighAlarmPortnread-onlycurrentOSC Rx Power High Alarm :This OID indicates the Rx Power of the OSC is higher than the alarm threshold<Help> This alarm indicates the Rx Power of the OSC is hi…
1.3.6.1.4.1.20044.114.2.3.3.50Tablepmoac20ilAlmlineOscThresholdsWarningsTablenot-accessiblecurrentList of pmoac20ilAlmlineOscThresholdsWarnings Article
1.3.6.1.4.1.20044.114.2.3.3.50.1Rowpmoac20ilAlmlineOscThresholdsWarningsEntrynot-accessiblecurrentRow definition for the pmoac20ilAlmlineOscThresholdsWarnings table
1.3.6.1.4.1.20044.114.2.3.3.50.1.1Columnpmoac20ilAlmlineOscThresholdsWarningsIndexread-onlycurrentIndex definition for the pmoac20ilAlmlineOscThresholdsWarnings table
1.3.6.1.4.1.20044.114.2.3.3.50.1.2Columnpmoac20ilAlmLineOscTxPwrLowWarningPortnread-onlycurrentOSC Tx Power Low Warning :This OID indicates the Tx Power of the OSC is lower than the warning threshold<Help> This alarm indicates the Tx Power of the OSC is …
1.3.6.1.4.1.20044.114.2.3.3.50.1.3Columnpmoac20ilAlmLineOscTxPwrHighWarningPortnread-onlycurrentOSC Tx Power High Warning :This OID indicates the Tx Power of the OSC is higher than the warning threshold<Help> This alarm indicates the Tx Power of the OSC i…
1.3.6.1.4.1.20044.114.2.3.3.50.1.4Columnpmoac20ilAlmLineOscTxBiasLowWarningPortnread-onlycurrentOSC Bias Current Low Warning :This OID indicates the OSC bias current is lower than the warning threshold <Help> This alarm indicates the OSC bias current is l…
1.3.6.1.4.1.20044.114.2.3.3.50.1.5Columnpmoac20ilAlmLineOscTxBiasHighWarningPortnread-onlycurrentOSC Bias Current High Warning :This OID indicates the OSC bias current is higher than the warning threshold <Help> This alarm indicates the OSC bias current is…
1.3.6.1.4.1.20044.114.2.3.3.50.1.6Columnpmoac20ilAlmLineOscVccLowWarningPortnread-onlycurrentOSC Vcc Low Warning :This OID indicates the Vcc of the OSC is lower than the warning threshold<Help> This alarm indicates the Vcc of the OSC is lower than the …
1.3.6.1.4.1.20044.114.2.3.3.50.1.7Columnpmoac20ilAlmLineOscVccHighWarningPortnread-onlycurrentOSC Vcc High Warning :This OID indicates the Vcc of the OSC is higher than the warning threshold<Help> This alarm indicates the Vcc of the OSC is higher than t…
1.3.6.1.4.1.20044.114.2.3.3.50.1.8Columnpmoac20ilAlmLineOscTempLowWarningPortnread-onlycurrentOSC Temperature Low Warning :This OID indicates the OSC temperature is lower than the warning threshold <Help> This alarm indicates the OSC temperature is lowe…
1.3.6.1.4.1.20044.114.2.3.3.50.1.9Columnpmoac20ilAlmLineOscTempHighWarningPortnread-onlycurrentOSC Temperature High Warning :This OID indicates the OSC temperature is higher than the warning threshold <Help> This alarm indicates the OSC temperature is hi…
1.3.6.1.4.1.20044.114.2.3.3.50.1.10Columnpmoac20ilAlmLineOscSpanlossLowWarningPortnread-onlycurrentOSC Span Loss Low Warning :This OID indicates the OSC Span Loss is 1dB lower than the span loss reference<Help> This alarm indicates the OSC Span Loss is 1dB l…
1.3.6.1.4.1.20044.114.2.3.3.50.1.11Columnpmoac20ilAlmLineOscSpanlossHighWarningPortnread-onlycurrentOSC Span Loss High Warning :This OID indicates the OSC Span Loss is 1dB higher than the span loss reference <Help> This alarm indicates the OSC Span Loss is 1d…
1.3.6.1.4.1.20044.114.2.3.3.50.1.16Columnpmoac20ilAlmLineOscRxPwrLowWarningPortnread-onlycurrentOSC Rx Power Low Warning :This OID indicates the Rx Power of the OSC is lower than the warning threshold<Help> This alarm indicates the Rx Power of the OSC is …
1.3.6.1.4.1.20044.114.2.3.3.50.1.17Columnpmoac20ilAlmLineOscRxPwrHighWarningPortnread-onlycurrentOSC Rx Power High Warning :This OID indicates the Rx Power of the OSC is higher than the warning threshold<Help> This alarm indicates the Rx Power of the OSC i…
1.3.6.1.4.1.20044.114.3Nodepmoac20ilmeasures
1.3.6.1.4.1.20044.114.3.1Nodepmoac20ilMesrOther
1.3.6.1.4.1.20044.114.3.1.80Scalarpmoac20ilMesrtempMeasread-onlycurrentModule Temperature :This OID gives the temperature of the PM (Temperature =AV_S16/256) (Unit = C) <Help> This measure gives the temperature of the module
1.3.6.1.4.1.20044.114.3.1.82Scalarpmoac20ilMesrmoduleTempMinread-onlycurrentMin Module Temperature :This OID gives the minimum temperature value of the Module (Temperature = AV_S16/256) (Unit = C) <Help> This Measure gives the minimum …
1.3.6.1.4.1.20044.114.3.1.83Scalarpmoac20ilMesrmoduleTempMaxread-onlycurrentMax Module Temperature :This OID gives the maximum temperature value of the Module (Temperature = AV_S16/256) (Unit = C) <Help> This Measure gives the maximum …
1.3.6.1.4.1.20044.114.3.2Nodepmoac20ilMesrClient
1.3.6.1.4.1.20044.114.3.2.32Scalarpmoac20ilMesrclientEdfaBiasMeasread-onlycurrentIL2 Pump Laser Current :This OID gives the pump laser current of the IL2 Optical Module (Current =AV_U16/20) (Unit = mA) <Help> This measure gives the bias of …
1.3.6.1.4.1.20044.114.3.2.33Scalarpmoac20ilMesrclientEdfaTxpwrMeasread-onlycurrentIL2 Tx Power :This OID gives the transmit power value of the IL2 Optical Module (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure gives the Tx opt…
1.3.6.1.4.1.20044.114.3.2.34Scalarpmoac20ilMesrclientEdfaRxpwrMeasread-onlycurrentIL2 Rx Power :This OID gives the receive power value of the IL2 Optical Module (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure gives the Rx opti…
1.3.6.1.4.1.20044.114.3.2.35Scalarpmoac20ilMesrclientEdfaGainMeasread-onlycurrentIL2 Gain Target :This OID gives the gain value of the IL2 Module (Gain =(AV_U16-32768)*0.005) (Unit = dB) <Help> This information gives the target gain of the …
1.3.6.1.4.1.20044.114.3.2.36Scalarpmoac20ilMesrclientOscSpanLossread-onlycurrentIL2 Input Span Loss :This OID indicates the attenuation of the span connected to the IL2 input (Power =(AV_U16-32768)*0.005) (Unit = dB) <Help> This measure in…
1.3.6.1.4.1.20044.114.3.2.37Scalarpmoac20ilMesrclientOscSpanLossRefread-onlycurrentIL2 Input Span Loss Ref :This OID indicates the referenced attenuation of the span connected to the IL2 input (Used to monitor the variation of the span loss) …
1.3.6.1.4.1.20044.114.3.2.38Scalarpmoac20ilMesrclientCorrectedGainread-onlycurrentIL2 Gain :This OID gives the gain value of the IL2 Module corrected by the ASE compensation mechanism (Gain =(AV_U16-32768)*0.005) (Unit = dB) <Help> This meas…
1.3.6.1.4.1.20044.114.3.2.39Scalarpmoac20ilMesrclientMsaInputPowerread-onlycurrentIL2 MSA Rx Power :This OID indicates the input power of the Mid Stage Access of the IL2 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicate…
1.3.6.1.4.1.20044.114.3.2.40Scalarpmoac20ilMesrclientMsaOutputPowerread-onlycurrentIL2 MSA Tx Power :This OID indicates the output power of the Mid Stage Access of the IL2 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicat…
1.3.6.1.4.1.20044.114.3.2.41Scalarpmoac20ilMesrclientMsaAttenuationread-onlycurrentIL2 MSA Attenuation :This OID indicates the attenuation applied on the Mid Stage Access of the IL2 (Attenuation =(AV_U16-32768)*0.005) (Unit = dB) <Help> This …
1.3.6.1.4.1.20044.114.3.2.42Scalarpmoac20ilMesrclientMsaAttenuationRefread-onlycurrentIL2 MSA Attenuation Ref :This OID indicates the reference attenuation stored for the Mid Stage Access of the In-Line1 (Used to monitor the variation of this at…
1.3.6.1.4.1.20044.114.3.3Nodepmoac20ilMesrLine
1.3.6.1.4.1.20044.114.3.3.48Scalarpmoac20ilMesrlineEdfaBiasMeasread-onlycurrentIL1 Pump Laser Current :This OID gives the pump laser current of the IL1 Optical Module (Current =AV_U16/20) (Unit = mA) <Help> This measure gives the bias of …
1.3.6.1.4.1.20044.114.3.3.49Scalarpmoac20ilMesrlineEdfaTxpwrMeasread-onlycurrentIL1 Tx Power :This OID gives the transmit power value of the IL1 Optical Module (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure gives the Tx opt…
1.3.6.1.4.1.20044.114.3.3.50Scalarpmoac20ilMesrlineEdfaRxpwrMeasread-onlycurrentIL1 Rx Power :This OID gives the receive power value of the IL1 Optical Module (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure gives the Rx opti…
1.3.6.1.4.1.20044.114.3.3.51Scalarpmoac20ilMesrlineEdfaGainMeasread-onlycurrentIL1 Gain Target :This OID gives the gain value of the IL1 Module (Gain =(AV_U16-32768)*0.005) (Unit = dB) <Help> This information gives the target gain of the …
1.3.6.1.4.1.20044.114.3.3.52Scalarpmoac20ilMesrlineOscSpanLossread-onlycurrentIL1 Input Span Loss :This OID indicates the attenuation of the span connected to the IL1 input (Power =(AV_U16-32768)*0.005) (Unit = dB) <Help> This measure in…
1.3.6.1.4.1.20044.114.3.3.53Scalarpmoac20ilMesrlineOscSpanLossRefread-onlycurrentIL1 Input Span Loss Ref :This OID indicates the referenced attenuation of the span connected to the IL1 input (Used to monitor the variation of the span loss) …
1.3.6.1.4.1.20044.114.3.3.54Scalarpmoac20ilMesrlineCorrectedGainread-onlycurrentIL1 Gain :This OID gives the gain value of the IL1 Module corrected by the ASE compensation mechanism (Gain =(AV_U16-32768)*0.005) (Unit = dB) <Help> This meas…
1.3.6.1.4.1.20044.114.3.3.55Scalarpmoac20ilMesrlineMsaInputPowerread-onlycurrentIL1 MSA Rx Power :This OID indicates the input power of the Mid Stage Access of the IL1 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicate…
1.3.6.1.4.1.20044.114.3.3.56Scalarpmoac20ilMesrlineMsaOutputPowerread-onlycurrentIL1 MSA Tx Power :This OID indicates the output power of the Mid Stage Access of the IL1 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicat…
1.3.6.1.4.1.20044.114.3.3.57Scalarpmoac20ilMesrlineMsaAttenuationread-onlycurrentIL1 MSA Attenuation :This OID indicates the attenuation applied on the Mid Stage Access of the IL1 (Attenuation =(AV_U16-32768)*0.005) (Unit = dB) <Help> This …
1.3.6.1.4.1.20044.114.3.3.58Scalarpmoac20ilMesrlineMsaAttenuationRefread-onlycurrentIL1 MSA Attenuation Ref :This OID indicates the reference attenuation stored for the Mid Stage Access of the IL1 (Used to monitor the variation of this attenua…
1.3.6.1.4.1.20044.114.3.3.64Tablepmoac20ilMesrlineOscTxPowerTablenot-accessiblecurrentList of pmoac20ilMesrlineOscTxPower Article
1.3.6.1.4.1.20044.114.3.3.64.1Rowpmoac20ilMesrlineOscTxPowerEntrynot-accessiblecurrentRow definition for the pmoac20ilMesrlineOscTxPower table
1.3.6.1.4.1.20044.114.3.3.64.1.1Columnpmoac20ilMesrlineOscTxPowerIndexread-onlycurrentIndex definition for the pmoac20ilMesrlineOscTxPower table
1.3.6.1.4.1.20044.114.3.3.64.1.2Columnpmoac20ilMesrlineOscTxPowerPortnread-onlycurrentOSC Tx Power :This OID gives the transmit power value of the Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit =…
1.3.6.1.4.1.20044.114.3.3.65Tablepmoac20ilMesrlineOscRxPowerTablenot-accessiblecurrentList of pmoac20ilMesrlineOscRxPower Article
1.3.6.1.4.1.20044.114.3.3.65.1Rowpmoac20ilMesrlineOscRxPowerEntrynot-accessiblecurrentRow definition for the pmoac20ilMesrlineOscRxPower table
1.3.6.1.4.1.20044.114.3.3.65.1.1Columnpmoac20ilMesrlineOscRxPowerIndexread-onlycurrentIndex definition for the pmoac20ilMesrlineOscRxPower table
1.3.6.1.4.1.20044.114.3.3.65.1.2Columnpmoac20ilMesrlineOscRxPowerPortnread-onlycurrentOSC Rx Power :This OID gives the receive power value of the Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dB…
1.3.6.1.4.1.20044.114.3.3.66Tablepmoac20ilMesrlineOscBiasTablenot-accessiblecurrentList of pmoac20ilMesrlineOscBias Article
1.3.6.1.4.1.20044.114.3.3.66.1Rowpmoac20ilMesrlineOscBiasEntrynot-accessiblecurrentRow definition for the pmoac20ilMesrlineOscBias table
1.3.6.1.4.1.20044.114.3.3.66.1.1Columnpmoac20ilMesrlineOscBiasIndexread-onlycurrentIndex definition for the pmoac20ilMesrlineOscBias table
1.3.6.1.4.1.20044.114.3.3.66.1.2Columnpmoac20ilMesrlineOscBiasPortnread-onlycurrentOSC Bias :This OID gives the Laser bias value of the Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV_U16/500) (Unit = mA) <Help> This…
1.3.6.1.4.1.20044.114.3.3.67Tablepmoac20ilMesrlineOscTempTablenot-accessiblecurrentList of pmoac20ilMesrlineOscTemp Article
1.3.6.1.4.1.20044.114.3.3.67.1Rowpmoac20ilMesrlineOscTempEntrynot-accessiblecurrentRow definition for the pmoac20ilMesrlineOscTemp table
1.3.6.1.4.1.20044.114.3.3.67.1.1Columnpmoac20ilMesrlineOscTempIndexread-onlycurrentIndex definition for the pmoac20ilMesrlineOscTemp table
1.3.6.1.4.1.20044.114.3.3.67.1.2Columnpmoac20ilMesrlineOscTempPortnread-onlycurrentOSC Temperature :This OID gives the Laser temperature value of the Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV_S16/256) (U…
1.3.6.1.4.1.20044.114.3.3.68Tablepmoac20ilMesrlineOscVoltTablenot-accessiblecurrentList of pmoac20ilMesrlineOscVolt Article
1.3.6.1.4.1.20044.114.3.3.68.1Rowpmoac20ilMesrlineOscVoltEntrynot-accessiblecurrentRow definition for the pmoac20ilMesrlineOscVolt table
1.3.6.1.4.1.20044.114.3.3.68.1.1Columnpmoac20ilMesrlineOscVoltIndexread-onlycurrentIndex definition for the pmoac20ilMesrlineOscVolt table
1.3.6.1.4.1.20044.114.3.3.68.1.2Columnpmoac20ilMesrlineOscVoltPortnread-onlycurrentOSC Voltage :This OID gives the Voltage value of the Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV_U16/10000) (Unit = V) <Help> …
1.3.6.1.4.1.20044.114.6Nodepmoac20ilcontrolsWrite
1.3.6.1.4.1.20044.114.6.1Nodepmoac20ilCtrlOther
1.3.6.1.4.1.20044.114.6.1.0Nodepmoac20ilCtrlsynth0
1.3.6.1.4.1.20044.114.6.1.0.1Scalarpmoac20ilCtrlConfLoadread-writecurrentLoad Configuration Tables :When set this enables loading from flash configuration1 into the module.
1.3.6.1.4.1.20044.114.6.1.0.9Scalarpmoac20ilCtrlConfFlashread-writecurrentWrite Configuration Tables :This bit saves the current configuration of the module as configuration in the flash. <Help> This control saves the customer config…
1.3.6.1.4.1.20044.114.6.1.0.13Scalarpmoac20ilCtrlConfClearread-writecurrentClear Configuration Tables :This bit clears the configuration tables from configuration in the flash. <Help> This control restores the default configuration of…
1.3.6.1.4.1.20044.114.6.1.5Nodepmoac20ilCtrlswMgnt
1.3.6.1.4.1.20044.114.6.1.5.2Scalarpmoac20ilCtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the Software. This reset is traffic affecting, and the configuration of Software is reloaded on start…
1.3.6.1.4.1.20044.114.6.1.5.3Scalarpmoac20ilCtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the Software. This reset is not traffic affecting, and the configuration of the Sofwtare remains unch…
1.3.6.1.4.1.20044.114.6.1.6Nodepmoac20ilCtrlsynth6
1.3.6.1.4.1.20044.114.6.1.6.1Scalarpmoac20ilCtrlCurrentGwResetread-writecurrentActive Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting.
1.3.6.1.4.1.20044.114.6.1.73Nodepmoac20ilCtrlledTest
1.3.6.1.4.1.20044.114.6.1.73.1Scalarpmoac20ilCtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.114.6.1.73.2Scalarpmoac20ilCtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.114.6.1.73.3Scalarpmoac20ilCtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.114.6.1.75Nodepmoac20ilCtrlmaintMode
1.3.6.1.4.1.20044.114.6.1.75.1Scalarpmoac20ilCtrlMaintenanceread-writecurrentPM Maintenance Mode :This OID sets the PM in maintenance mode <Help> This control enables the maintenance mode of the module
1.3.6.1.4.1.20044.114.6.1.76Nodepmoac20ilCtrlaprRestart
1.3.6.1.4.1.20044.114.6.1.76.1Scalarpmoac20ilCtrlAprManualRestartread-writecurrentAPR Manual Restart :This OID initiates the Restart mechanism to retrieve from the APR state.<Help> This control initiates the Restart mechanism to retrieve fro…
1.3.6.1.4.1.20044.114.6.2Nodepmoac20ilCtrlClient
1.3.6.1.4.1.20044.114.6.2.33Nodepmoac20ilCtrlclientOscInputSpanLoss
1.3.6.1.4.1.20044.114.6.2.33.1Scalarpmoac20ilCtrlClientSpanLossread-writecurrentStore IL2 Input Span Loss :This OID stores the current input span Loss as a reference to monitor the span loss variation <Help> This parameter stores the curre…
1.3.6.1.4.1.20044.114.6.2.34Scalarpmoac20ilCtrlclientGainCstMonitorValueread-writecurrentIL2 Fiber Aging Period :This OID sets the value of the monitoring period to detect a fiber aging. (Unit = s) This value sets the monitoring period to detect a …
1.3.6.1.4.1.20044.114.6.2.36Scalarpmoac20ilCtrlclientGainSettingValueread-writecurrentIL2 Gain Target :This OID sets the value of the nominal gain of the IL2lifier Module (active only in constant output power mode) (AV=(Gain/0,005) + 32768) (Uni…
1.3.6.1.4.1.20044.114.6.2.37Nodepmoac20ilCtrlclientGainProcessing
1.3.6.1.4.1.20044.114.6.2.37.1Scalarpmoac20ilCtrlClientGainProcread-writecurrentIL2 Fiber Aging Compensation :This OID initiates the automatic nominal gain adjustment on the IL2lifier Module<Help> This control initiates the automatic nomin…
1.3.6.1.4.1.20044.114.6.2.38Scalarpmoac20ilCtrlclientGainCstFiberAgingMarginValueread-writecurrentIL2 Aging Threshold :This OID sets the threshold to consider the power drop as a fiber aging. (active only in constant gain mode) (AV=(Gain/0,005) + 32768) (Un…
1.3.6.1.4.1.20044.114.6.2.40Nodepmoac20ilCtrlclientMsaAttenuationValue
1.3.6.1.4.1.20044.114.6.2.40.1Scalarpmoac20ilCtrlClientAttenuationread-writecurrentStore IL2 MSA Attenuation :This OID stores the current attenuation applied on the Mid Stage Access of the IL2 (used for monitoring the MSA attenuation variatio…
1.3.6.1.4.1.20044.114.6.2.41Scalarpmoac20ilCtrlclientTlvPreviousAmpPwrWread-writecurrentPrevious Amplifier Output Power :This OID sets the value of the previous Amplifier output power to be used to compute the local span loss monitoring (AV=(Gain/…
1.3.6.1.4.1.20044.114.6.2.42Scalarpmoac20ilCtrlclientTlvPreviousRoadmLambdaNbWread-writecurrentPrevious Roadm Lambda Number :This OID sets the value of the previous Roadm wavelength number to be computed locally (Unit = Lambdas) <Help> This parameter sto…
1.3.6.1.4.1.20044.114.6.2.57Scalarpmoac20ilCtrllineTlvPreviousAmpPwrWread-writecurrentPrevious Amplifier Output Power :This OID sets the value of the previous Amplifier output power to be used to compute the local span loss monitoring (AV=(Gain/…
1.3.6.1.4.1.20044.114.6.2.58Scalarpmoac20ilCtrllineTlvPreviousRoadmLambdaNbWread-writecurrentPrevious Roadm Lambda Number :This OID sets the value of the previous Roadm wavelength number to be computed locally (Unit = Lambdas) <Help> This parameter sto…
1.3.6.1.4.1.20044.114.6.3Nodepmoac20ilCtrlLine
1.3.6.1.4.1.20044.114.6.3.49Nodepmoac20ilCtrllineOscInputSpanLoss
1.3.6.1.4.1.20044.114.6.3.49.1Scalarpmoac20ilCtrlLineSpanLossread-writecurrentStore IL1 Input Span Loss :This OID stores the current input span Loss as a reference to monitor the span loss variation<Help> This parameter stores the curren…
1.3.6.1.4.1.20044.114.6.3.50Scalarpmoac20ilCtrllineGainCstMonitorValueread-writecurrentIL1 Fiber Aging Period :This OID sets the value of the monitoring period to detect a fiber aging. (Unit = s) This value sets the monitoring period to detect a …
1.3.6.1.4.1.20044.114.6.3.52Scalarpmoac20ilCtrllineGainSettingValueread-writecurrentIL1 Gain Target :This OID sets the value of the nominal gain of the IL1 Module (active only in constant output power mode) (AV=(Gain/0,005) + 32768) (Unit = dB…
1.3.6.1.4.1.20044.114.6.3.53Nodepmoac20ilCtrllineGainProcessing
1.3.6.1.4.1.20044.114.6.3.53.1Scalarpmoac20ilCtrlLineGainProcread-writecurrentIL1 Fiber Aging Compensation :This OID initiates the automatic nominal gain adjustment on the IL1 Module<Help> This control initiates the automatic nominal gai…
1.3.6.1.4.1.20044.114.6.3.54Scalarpmoac20ilCtrllineGainCstFiberAgingMarginValueread-writecurrentIL1 Aging Threshold :This OID sets the threshold to consider the power drop as a fiber aging. (active only in constant gain mode) (AV=(Gain/0,005) + 32768) (Un…
1.3.6.1.4.1.20044.114.6.3.56Nodepmoac20ilCtrllineMsaAttenuationValue
1.3.6.1.4.1.20044.114.6.3.56.1Scalarpmoac20ilCtrlLineAttenuationread-writecurrentStore IL1 MSA Attenuation :This OID stores the current attenuation applied on the Mid Stage Access of the IL1 (used for monitoring the MSA attenuation variatio…
1.3.6.1.4.1.20044.114.7Nodepmoac20ilri
1.3.6.1.4.1.20044.114.7.2Scalarpmoac20ilRinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.114.7.3Scalarpmoac20ilRinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.114.7.4Scalarpmoac20ilRinvModulePlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.114.7.5Scalarpmoac20ilRinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.114.7.6Scalarpmoac20ilRinvGwPlatformread-onlycurrentGW platform description: This OID contains the description of the gateware platform.
1.3.6.1.4.1.20044.114.7.7Tablepmoac20ilRinvBoosterTablenot-accessiblecurrentList of the Boosters on the selected module
1.3.6.1.4.1.20044.114.7.7.1Rowpmoac20ilRinvBoosterEntrynot-accessiblecurrentRow definition for the Boosters table
1.3.6.1.4.1.20044.114.7.7.1.1Columnpmoac20ilRinvBoosterIndexread-onlycurrentIndex for Booster table
1.3.6.1.4.1.20044.114.7.7.1.2Columnpmoac20ilRinvBoosterread-onlycurrentInventory for the Booster: This OID contains the inventory for the Booster
1.3.6.1.4.1.20044.114.7.8Tablepmoac20ilRinvPreAmpTablenot-accessiblecurrentList of the PreAmps on the selected module
1.3.6.1.4.1.20044.114.7.8.1Rowpmoac20ilRinvPreAmpEntrynot-accessiblecurrentRow definition for the PreAmp table
1.3.6.1.4.1.20044.114.7.8.1.1Columnpmoac20ilRinvPreAmpIndexread-onlycurrentIndex for PreAmp table
1.3.6.1.4.1.20044.114.7.8.1.2Columnpmoac20ilRinvPreAmpread-onlycurrentInventory for the PreAmp: This OID contains the inventory for the PreAmp
1.3.6.1.4.1.20044.114.9Nodepmoac20ilConfig
1.3.6.1.4.1.20044.114.9.1Nodepmoac20ilCfgNoValue
1.3.6.1.4.1.20044.114.9.1.1Nodepmoac20iltableclientStartup
1.3.6.1.4.1.20044.114.9.1.1.2Scalarpmoac20ilCfgclientEdfaLaserCtrlread-writecurrentDefault Settings on Client Laser :This OID configures the default initialisation settings on the client laser.
1.3.6.1.4.1.20044.114.9.1.1.3Scalarpmoac20ilCfgclientEdfaLaserModeread-writecurrentDefault Settings on Client mode :This OID configures the default mode on the client amplifier.
1.3.6.1.4.1.20044.114.9.1.1.4Scalarpmoac20ilCfgclientGainValueread-writecurrentDefault Settings on Client Gain :This OID configures the default gain on the client amplifier.
1.3.6.1.4.1.20044.114.9.1.1.5Scalarpmoac20ilCfgclientTiltValueread-writecurrentDefault Settings on Client Tilt :This OID configures the default tilt on the client amplifier.
1.3.6.1.4.1.20044.114.9.1.1.6Scalarpmoac20ilCfgclientMsaLossread-writecurrentDefault Settings on Client MSA :This OID configures the default MSA value on the client amplifier.
1.3.6.1.4.1.20044.114.9.1.1.7Scalarpmoac20ilCfgclientOutputPowerValueread-writecurrentDefault Settings on Client Output power :This OID configures the default Output power value on the client amplifier.
1.3.6.1.4.1.20044.114.9.1.1.8Scalarpmoac20ilCfgclientAseCompensationread-writecurrentDefault Settings on Client ASE :This OID configures the default ASE compensation value on the client amplifier.
1.3.6.1.4.1.20044.114.9.1.1.10Scalarpmoac20ilCfgclientGainHighAlarmread-writecurrentDefault setting on Gain High Alarm :This register configures the default initialisation settings on the alarm threshold
1.3.6.1.4.1.20044.114.9.1.1.11Scalarpmoac20ilCfgclientGainHighWarningread-writecurrentDefault setting on Gain High Warning :This register configures the default initialisation settings on the warning threshold
1.3.6.1.4.1.20044.114.9.1.1.12Scalarpmoac20ilCfgclientGainLowWarningread-writecurrentDefault setting on Gain Low Warning :This register configures the default initialisation settings on the warning threshold
1.3.6.1.4.1.20044.114.9.1.1.13Scalarpmoac20ilCfgclientGainLowAlarmread-writecurrentDefault setting on Gain Low Alarm :This register configures the default initialisation settings on the alarm threshold
1.3.6.1.4.1.20044.114.9.1.1.14Scalarpmoac20ilCfgclientLossOfSignalread-writecurrentDefault setting on Loss Of Signal :This register configures the default initialisation settings on the Loss Of Signal threshold
1.3.6.1.4.1.20044.114.9.2Nodepmoac20ilCfgLineStartUp
1.3.6.1.4.1.20044.114.9.2.1Nodepmoac20iltablelineStartup
1.3.6.1.4.1.20044.114.9.2.1.2Scalarpmoac20ilCfglineEdfaLaserCtrlread-writecurrentDefault Settings on Line Laser :This OID configures the default initialisation settings on the line laser.
1.3.6.1.4.1.20044.114.9.2.1.3Scalarpmoac20ilCfglineEdfaLaserModeread-writecurrentDefault Settings on Line mode :This OID configures the default mode on the line amplifier.
1.3.6.1.4.1.20044.114.9.2.1.4Scalarpmoac20ilCfglineGainValueread-writecurrentDefault Settings on Line Gain :This OID configures the default gain on the line amplifier.
1.3.6.1.4.1.20044.114.9.2.1.5Scalarpmoac20ilCfglineTiltValueread-writecurrentDefault Settings on Line Tilt :This OID configures the default tilt on the line amplifier.
1.3.6.1.4.1.20044.114.9.2.1.6Scalarpmoac20ilCfglineMsaLossread-writecurrentDefault Settings on Line MSA :This OID configures the default MSA value on the line amplifier.
1.3.6.1.4.1.20044.114.9.2.1.7Scalarpmoac20ilCfglineOutputPowerValueread-writecurrentDefault Settings on Line Output power :This OID configures the default Output power value on the line amplifier.
1.3.6.1.4.1.20044.114.9.2.1.8Scalarpmoac20ilCfglineAseCompensationread-writecurrentDefault Settings on Line ASE :This OID configures the default ASE compensation value on the line amplifier.
1.3.6.1.4.1.20044.114.9.2.1.10Scalarpmoac20ilCfglineGainHighAlarmread-writecurrentDefault setting on Gain High Alarm :This register configures the default initialisation settings on the alarm threshold
1.3.6.1.4.1.20044.114.9.2.1.11Scalarpmoac20ilCfglineGainHighWarningread-writecurrentDefault setting on Gain High Warning :This register configures the default initialisation settings on the warning threshold
1.3.6.1.4.1.20044.114.9.2.1.12Scalarpmoac20ilCfglineGainLowWarningread-writecurrentDefault setting on Gain Low Warning :This register configures the default initialisation settings on the warning threshold
1.3.6.1.4.1.20044.114.9.2.1.13Scalarpmoac20ilCfglineGainLowAlarmread-writecurrentDefault setting on Gain Low Alarm :This register configures the default initialisation settings on the alarm threshold
1.3.6.1.4.1.20044.114.9.2.1.14Scalarpmoac20ilCfglineLossOfSignalread-writecurrentDefault setting on Loss Of Signal :This register configures the default initialisation settings on the Loss Of Signal threshold
1.3.6.1.4.1.20044.114.9.2.1.18Scalarpmoac20ilCfglossEnableread-writecurrentDefault setting on Loss Of Signal :This register configures the default initialisation settings on the Loss Of Signal
1.3.6.1.4.1.20044.114.9.3Nodepmoac20ilCfgClientSupvStartUp
1.3.6.1.4.1.20044.114.9.3.1Tablepmoac20ilCfgLineStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.114.9.3.1.1Rowpmoac20ilCfgLineStartupEntrynot-accessiblecurrentRow definition for the clientSupvStartUp table
1.3.6.1.4.1.20044.114.9.3.1.1.1Columnpmoac20ilCfgLineStartupIndexread-onlycurrentIndex definition for the lineStartup table
1.3.6.1.4.1.20044.114.9.3.1.1.3Columnpmoac20ilCfgLineOscLaserCtrlPortnread-writecurrentDefault Settings on OSC Laser :This OID configures the default initialisation settings on the OSC
1.3.6.1.4.1.20044.114.9.3.1.1.4Columnpmoac20ilCfgLineOscOosPortnread-writecurrentDefault Settings on OSC mode :This OID configures the default mode on the OSC
1.3.6.1.4.1.20044.114.9.3.1.1.5Columnpmoac20ilCfgLineOscSpanLengthPortnread-writecurrentDefault Settings on OSC span length :This OID defines the length of the span connected on the OSC port
1.3.6.1.4.1.20044.114.9.3.1.1.6Columnpmoac20ilCfgLineOscCorrectionFactorPortnread-writecurrentDefault Settings on OSC attenuation corrector factor :This OID defines the correction factor to apply on the span attenuation measure on the OSC Channel (1510)…
1.3.6.1.4.1.20044.114.9.3.1.1.11Columnpmoac20ilCfgLineSpanLossHighAlarmPortnread-writecurrentDefault setting on Span Loss High Alarm :This register configures the default initialisation settings on the alarm threshold
1.3.6.1.4.1.20044.114.9.3.1.1.12Columnpmoac20ilCfgLineSpanLossHighWarningPortnread-writecurrentDefault setting on Span Loss High Warning :This register configures the default initialisation settings on the warning threshold
1.3.6.1.4.1.20044.114.9.3.1.1.13Columnpmoac20ilCfgLineSpanLossLowWarningPortnread-writecurrentDefault setting on Span Loss Low Warning :This register configures the default initialisation settings on the warning threshold
1.3.6.1.4.1.20044.114.9.3.1.1.14Columnpmoac20ilCfgLineSpanLossLowAlarmPortnread-writecurrentDefault setting on Span Loss Low Alarm :This register configures the default initialisation settings on the alarm threshold
1.3.6.1.4.1.20044.114.9.4Nodepmoac20ilCfgLabels
1.3.6.1.4.1.20044.114.9.4.1Tablepmoac20ilCfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.114.9.4.1.1Rowpmoac20ilCfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.114.9.4.1.1.1Columnpmoac20ilCfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.114.9.4.1.1.3Columnpmoac20ilCfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.114.9.4.2Tablepmoac20ilCfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.114.9.4.2.1Rowpmoac20ilCfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.114.9.4.2.1.1Columnpmoac20ilCfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.114.9.4.2.1.3Columnpmoac20ilCfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.114.9.257Scalarpmoac20ilCfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.114.10Nodepmoac20iltraps
1.3.6.1.4.1.20044.114.10.4Scalarpmoac20iltrapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.114.10.34Notificationpmoac20ilLineTrapCritGoesOncurrentCritical Line default is activated
1.3.6.1.4.1.20044.114.10.35Notificationpmoac20ilLineTrapCritGoesOffcurrentCritical Line default disappeared
1.3.6.1.4.1.20044.114.10.44Notificationpmoac20ilClientTrapCritGoesOncurrentCritical client default is activated
1.3.6.1.4.1.20044.114.10.45Notificationpmoac20ilClientTrapCritGoesOffcurrentCritical client default disappeared
1.3.6.1.4.1.20044.114.10.50Notificationpmoac20ilPowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.114.10.51Notificationpmoac20ilPowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared
Type Definitions
NameSyntaxStatusDescription
Pmoac20ilaprModeINTEGER { pmoac20ilaproffmode(0), pmoac20ilaprsemiautomode(1), pmoac20ilaprautomode(2) pmoac20ilaprlossforwardingmode(3) pmoac20ilaprrepeatmode(4) }currentDifferent modes on APR
Pmoac20ilBoosterCstGainAdjModeINTEGER { pmoac20ilboostercstgainadjsemiautomode(1), pmoac20ilboostercstgainadjautomode(2) }currentDifferent modes when constant Gain
Pmoac20ilBoosterGainAdjModeINTEGER { pmoac20ilboostergainadjmanualmode(0), pmoac20ilboostergainadjsemiautomode(1), pmoac20ilboostergainadjautomode(2) }currentDifferent modes on Gain
Pmoac20ilboosterModeINTEGER { pmoac20ilboosterdefaultmode(0), pmoac20ilboosterconstantcurrentmode(1), pmoac20ilboosterconstantpowermode(2) pmoac20ilboosterconstantgainmode(3) pmoac20ilboosterpoutpinmode(4) pmoac20ilboostermanualmode(5) pmoac20ilboosterfeedforwardmode(6) pmoac20ilboostertransientsupmode(7) }currentDifferent modes on OA booster
Pmoac20ilPreAmpCstGainAdjModeINTEGER { pmoac20ilpreampcstgainadjsemiautomode(1), pmoac20ilpreampcstgainadjautomode(2) }currentDifferent modes when constant Gain
Pmoac20ilPreAmpGainAdjModeINTEGER { pmoac20ilpreampgainadjmanualmode(0), pmoac20ilpreampgainadjsemiautomode(1), pmoac20ilpreampgainadjautomode(2) }currentDifferent modes on Gain
Pmoac20ilpreampModeINTEGER { pmoac20ilpreampdefaultmode(0), pmoac20ilpreampconstantcurrentmode(1), pmoac20ilpreampconstantpowermode(2) pmoac20ilpreampconstantgainmode(3) pmoac20ilpreamppoutpinmode(4) pmoac20ilpreampmanualmode(5) pmoac20ilpreampfeedforwardmode(6) pmoac20ilpreamptransientsupmode(7) }currentDifferent modes on OA preamp