EKINOPS-Pmoailhcs-MIB
287 objects
Creation
Imported Objects
| EKINOPS-MIB | EkiApiState EkiMeasureType EkiMode ekinops EkiOnOff EkiProtocol EkiState EkiSynchroMode |
| SNMPv2-SMI | Counter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20044.62 | Identitymodulepmoailhcs | Creation | ||
| 1.3.6.1.4.1.20044.62.2 | Nodepmoailhcsalarms | |||
| 1.3.6.1.4.1.20044.62.2.1 | NodepmoailhcsAlmOther | |||
| 1.3.6.1.4.1.20044.62.2.1.1 | NodepmoailhcsAlmOtherNurg | |||
| 1.3.6.1.4.1.20044.62.2.1.1.2 | NodepmoailhcsAlmsynthAlm2 | |||
| 1.3.6.1.4.1.20044.62.2.1.1.2.1 | ScalarpmoailhcsAlmConfTableSave | read-only | current | PM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> other… |
| 1.3.6.1.4.1.20044.62.2.1.1.2.2 | ScalarpmoailhcsAlmInvUpload | read-only | current | Inventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> other (1) <Alarmtype> other (1) <Polarit… |
| 1.3.6.1.4.1.20044.62.2.1.1.2.3 | ScalarpmoailhcsAlmConfTableLoad | read-only | current | PM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> other (1) <Alarmt… |
| 1.3.6.1.4.1.20044.62.2.1.1.75 | NodepmoailhcsAlmfoaWarnings | |||
| 1.3.6.1.4.1.20044.62.2.1.1.75.7 | ScalarpmoailhcsAlmTermpLowWarning | read-only | current | Temperature Low Warning :This OID indicates that the PM temperature if lower than the Warning threshold <Condtype> TERMP_LOW_WARNING <Probcause> temperatureUna… |
| 1.3.6.1.4.1.20044.62.2.1.1.75.8 | ScalarpmoailhcsAlmTempHighWarning | read-only | current | Temperature High Warning :This OID indicates that the PM temperature if higher than the Warning threshold <Condtype> TEMP_HIGH_WARNING <Probcause> temperatureU… |
| 1.3.6.1.4.1.20044.62.2.1.2 | NodepmoailhcsAlmOtherUrg | |||
| 1.3.6.1.4.1.20044.62.2.1.2.74 | NodepmoailhcsAlmfoaAlarms | |||
| 1.3.6.1.4.1.20044.62.2.1.2.74.7 | ScalarpmoailhcsAlmTermpLowAlarm | read-only | current | Temperature Low Alarm :This OID indicates that the PM temperature if lower than the alarm threshold <Condtype> TERMP_LOW_ALARM <Probcause> temperatureUnaccepta… |
| 1.3.6.1.4.1.20044.62.2.1.2.74.8 | ScalarpmoailhcsAlmTempHighAlarm | read-only | current | Temperature High Alarm :This OID indicates that the PM temperature is higher than the alarm threshold <Condtype> TEMP_HIGH_ALARM <Probcause> temperatureUnaccep… |
| 1.3.6.1.4.1.20044.62.2.1.3 | NodepmoailhcsAlmOtherCrit | |||
| 1.3.6.1.4.1.20044.62.2.1.3.0 | NodepmoailhcsAlmsynthAlm0 | |||
| 1.3.6.1.4.1.20044.62.2.1.3.0.1 | ScalarpmoailhcsAlmMaintenanceMode | read-only | current | Maintenance Mode :This OID indicates that the PM is in maintenance mode <Help> This status indiates if the module is currently in maintenance mode <Condtype> M… |
| 1.3.6.1.4.1.20044.62.2.1.3.0.2 | ScalarpmoailhcsAlmAprOn | read-only | current | Automatic Power Reduction :This OID indicates that the APR algorithm has been operated and the output of the lasers are shutdown <Help> The APR algorithm has b… |
| 1.3.6.1.4.1.20044.62.2.1.3.0.9 | ScalarpmoailhcsAlmModGlobFail | read-only | current | Module Failure :This OID is set on detection of a failure originating from the PM <Condtype> MOD_GLOB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> sy… |
| 1.3.6.1.4.1.20044.62.2.1.3.0.10 | ScalarpmoailhcsAlmUpEdfaInitNotCompl | read-only | current | IL1 Not Initialized :This OID indicates that the initialisation of the IL1 is not completed <Help> This status indicates if the IL1 has been correctly initiali… |
| 1.3.6.1.4.1.20044.62.2.1.3.0.11 | ScalarpmoailhcsAlmDwEdfaInitNotCompl | read-only | current | IL2 Not Initialized :This OID indicates that the initialisation of the IL2 is not completed <Help> This status indicates if the IL2 has been correctly initiali… |
| 1.3.6.1.4.1.20044.62.2.1.3.0.12 | ScalarpmoailhcsAlmExtPump1NotLocked | read-only | current | External Pump Not Detected :This OID indicates that the first external pump is not detected by the amplifier module <Help> This alarm indicates if the external… |
| 1.3.6.1.4.1.20044.62.2.1.3.0.15 | ScalarpmoailhcsAlmDefFuseA | read-only | current | Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.62.2.1.3.0.16 | ScalarpmoailhcsAlmDefFuseB | read-only | current | Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.62.2.2 | NodepmoailhcsAlmClient | |||
| 1.3.6.1.4.1.20044.62.2.2.1 | NodepmoailhcsAlmClientNurg | |||
| 1.3.6.1.4.1.20044.62.2.2.1.33 | NodepmoailhcsAlmclientEdfaWarnings | |||
| 1.3.6.1.4.1.20044.62.2.2.1.33.1 | ScalarpmoailhcsAlmClientGainLowWarning | read-only | current | IL2 Gain Low Warning :This OID indicates that the Gain is lower than the Warning theshold of the IL2 Module <Help> This alarm indicates if the IL2 gain is too … |
| 1.3.6.1.4.1.20044.62.2.2.1.33.2 | ScalarpmoailhcsAlmClientGainHighWarning | read-only | current | IL2 Gain High Warning :This OID indicates that the Gain is higher than the Warning threshold of the IL2 Module <Help> This alarm indicates if the IL2 gain is t… |
| 1.3.6.1.4.1.20044.62.2.2.1.33.3 | ScalarpmoailhcsAlmClientInputPwrLowWarning | read-only | current | IL2 Rx Pwr Low Warning :This OID indicates that the Receive Power is lower than the Warning theshold of the IL2 Optical Module <Help> This warning indicates if… |
| 1.3.6.1.4.1.20044.62.2.2.1.33.4 | ScalarpmoailhcsAlmClientInputPwrHighWarning | read-only | current | IL2 Rx Pwr High Warning :This OID indicates that the Receive Power is higher than the Warning theshold of the IL2 Optical Module <Help> This warning indicates … |
| 1.3.6.1.4.1.20044.62.2.2.1.33.5 | ScalarpmoailhcsAlmClientOutputPwrLowWarning | read-only | current | IL2 Tx Pwr Low Warning :This OID indicates that the Transmit Power is lower than the Warning theshold of the IL2 Optical Module <Help> This warning indicates i… |
| 1.3.6.1.4.1.20044.62.2.2.1.33.6 | ScalarpmoailhcsAlmClientOutputPwrHighWarning | read-only | current | IL2 Tx Pwr High Warning :This OID indicates that the Transmit Power is higher than the Warning theshold of the IL2 Optical Module <Help> This warning indicates… |
| 1.3.6.1.4.1.20044.62.2.2.1.33.7 | ScalarpmoailhcsAlmClientBiasLowWarning | read-only | current | IL2 Bias Low Warning :This OID indicates that the Bias is lower than the Warning theshold of the IL2 Optical Module <Help> This warning indicates if the IL2 bi… |
| 1.3.6.1.4.1.20044.62.2.2.1.33.8 | ScalarpmoailhcsAlmClientBiasHighWarning | read-only | current | IL2 Bias High Warning :This OID indicates that the Bias is higher than the Warning theshold of the IL2 Optical Module <Help> This warning indicates if the IL2 … |
| 1.3.6.1.4.1.20044.62.2.2.2 | NodepmoailhcsAlmClientUrg | |||
| 1.3.6.1.4.1.20044.62.2.2.2.32 | NodepmoailhcsAlmclientEdfaAlarms1 | |||
| 1.3.6.1.4.1.20044.62.2.2.2.32.1 | ScalarpmoailhcsAlmClientGainLowAlarm | read-only | current | IL2 Gain Low Alarm :This OID indicates that the Gain is lower than the alarm theshold of the IL2 Module <Help> This alarm indicates if the IL2 gain is too low … |
| 1.3.6.1.4.1.20044.62.2.2.2.32.2 | ScalarpmoailhcsAlmClientGainHighAlarm | read-only | current | IL2 Gain High Alarm :This OID indicates that the Gain is higher than the alarm threshold of the IL2 Module <Help> This alarm indicates if the IL2 gain is too h… |
| 1.3.6.1.4.1.20044.62.2.2.2.32.3 | ScalarpmoailhcsAlmClientInputPwrLowAlarm | read-only | current | IL2 Rx Pwr Low Alarm :This OID indicates that the Receive Power is lower than the alarm theshold of the IL2 Optical Module <Help> This alarm indicates if the I… |
| 1.3.6.1.4.1.20044.62.2.2.2.32.4 | ScalarpmoailhcsAlmClientInputPwrHighAlarm | read-only | current | IL2 Rx Pwr High Alarm :This OID indicates that the Receive Power is higher than the alarm theshold of the IL2 Optical Module <Help> This alarm indicates if the… |
| 1.3.6.1.4.1.20044.62.2.2.2.32.5 | ScalarpmoailhcsAlmClientOutputPwrLowAlarm | read-only | current | IL2 Tx Pwr Low Alarm :This OID indicates that the Transmit Power is lower than the alarm theshold of the IL2 Optical Module <Help> This alarm indicates if the … |
| 1.3.6.1.4.1.20044.62.2.2.2.32.6 | ScalarpmoailhcsAlmClientOutputPwrHighAlarm | read-only | current | IL2 Tx Pwr High Alarm :This OID indicates that the Transmit Power is higher than the alarm theshold of the IL2 Optical Module <Help> This alarm indicates if th… |
| 1.3.6.1.4.1.20044.62.2.2.2.32.7 | ScalarpmoailhcsAlmClientBiasLowAlarm | read-only | current | IL2 Bias Low Alarm :This OID indicates that the Bias is lower than the alarm theshold of the IL2 Optical Module <Help> This alarm indicates if the IL2 bias is … |
| 1.3.6.1.4.1.20044.62.2.2.2.32.8 | ScalarpmoailhcsAlmClientBiasHighAlarm | read-only | current | IL2 Bias High Alarm :This OID indicates that the Bias is higher than the alarm theshold of the IL2 Optical Module <Help> This alarm indicates if the IL2 bias i… |
| 1.3.6.1.4.1.20044.62.2.2.3 | NodepmoailhcsAlmClientCrit | |||
| 1.3.6.1.4.1.20044.62.2.2.3.8 | NodepmoailhcsAlmsynthAlm8 | |||
| 1.3.6.1.4.1.20044.62.2.2.3.8.4 | ScalarpmoailhcsAlmClientHwFail | read-only | current | Client Port HW Failure :This OID indicates a failure on Client port, most probably caused by a HW issue <Condtype> CLIENT_HW_FAIL <Probcause> equipmentMalfunct… |
| 1.3.6.1.4.1.20044.62.2.2.3.8.5 | ScalarpmoailhcsAlmClientTxOff | read-only | current | IL2 Optical Output Shutdown :This OID indicates the IL2 optical output power is on <Help> This status indicates if the IL2 laser pump transceiver laser is ON o… |
| 1.3.6.1.4.1.20044.62.2.2.3.8.12 | ScalarpmoailhcsAlmClientFail | read-only | current | Client Port Failure :This OID indicates a failure on the Client port <Condtype> CLIENT_FAIL <Probcause> bandwidthReduced(4) <Alarmtype> synthesisAlarm (12) <Po… |
| 1.3.6.1.4.1.20044.62.2.2.3.8.13 | ScalarpmoailhcsAlmClientExtPumpFail | read-only | current | IL2 External Pump Fail :This OID indicates that the external pump linked to the IL2 is in fail condition <Help> This alarm indicates if the external pump linke… |
| 1.3.6.1.4.1.20044.62.2.2.3.8.14 | ScalarpmoailhcsAlmSupvbFail | read-only | current | : <Condtype> SUPVB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> equipmentAlarm (5) <Polarity> (2) |
| 1.3.6.1.4.1.20044.62.2.2.3.35 | NodepmoailhcsAlmclientEdfaAlarms2 | |||
| 1.3.6.1.4.1.20044.62.2.2.3.35.1 | ScalarpmoailhcsAlmClientEdfaNr | read-only | current | IL2 Optical Module Not Ready :This OID indicates that the IL2 Optical Module is not ready <Help> This status indicates if the IL2 has been correctly initialize… |
| 1.3.6.1.4.1.20044.62.2.2.3.35.2 | ScalarpmoailhcsAlmClientEdfaTecFail | read-only | current | IL2 TEC Fail :This OID indicates that the TEC is in fail condition on the IL2 Optical Module <Help> This alarm indicates if the TEC of the IL2 is in fail condi… |
| 1.3.6.1.4.1.20044.62.2.2.3.35.3 | ScalarpmoailhcsAlmClientEdfaLaserFail | read-only | current | IL2 Pump Laser Fail :This OID indicates a Transmit Laser Fail on the IL2 Optical Module <Help> This alarm indicates if the laser of the IL2 is in fail conditio… |
| 1.3.6.1.4.1.20044.62.2.2.3.35.4 | ScalarpmoailhcsAlmClientEdfaLos | read-only | current | IL2 Loss Of Signal :This OID indicates a Loss of Signal on the IL2 Optical Module <Help> This alarm indicates if an optical signal is detected on the IL2 input… |
| 1.3.6.1.4.1.20044.62.2.2.3.35.5 | ScalarpmoailhcsAlmClientExtPumpEdfaLowCurrent | read-only | current | IL2 Pump Low Current :This OID indicates that the EDFA pump current of IL2 is too low because of the external pump high power<Help> This alarm (only active whe… |
| 1.3.6.1.4.1.20044.62.2.2.3.35.6 | ScalarpmoailhcsAlmClientGainOutOfRange | read-only | current | IL2 Gain Out Of Range :This OID indicates the target gain of the IL2 is out of range (18-32dB), the flatness of the Booster is not guaranteed.<Help> This alarm… |
| 1.3.6.1.4.1.20044.62.2.2.3.37 | NodepmoailhcsAlmclientMsaAlarms | |||
| 1.3.6.1.4.1.20044.62.2.2.3.37.1 | ScalarpmoailhcsAlmClientMsaLos | read-only | current | IL2 MSA Loss Of Signal :This OID indicates a Loss of Signal is detected on the Mid Stage Access of the IL2 EDFAThis alarm indicates a Loss of Signal is detecte… |
| 1.3.6.1.4.1.20044.62.2.2.3.37.2 | ScalarpmoailhcsAlmClientMsaAttenuation | read-only | current | IL2 MSA Attenuation Alarm :This OID indicates the attenuation on the IL2 Mid Stage access has changed.This alarm indicates the attenuation on the IL2 Mid Stage… |
| 1.3.6.1.4.1.20044.62.2.3 | NodepmoailhcsAlmLine | |||
| 1.3.6.1.4.1.20044.62.2.3.1 | NodepmoailhcsAlmLineNurg | |||
| 1.3.6.1.4.1.20044.62.2.3.1.41 | NodepmoailhcsAlmlineEdfaWarnings | |||
| 1.3.6.1.4.1.20044.62.2.3.1.41.1 | ScalarpmoailhcsAlmLineGainLowWarning | read-only | current | IL1 Gain Low Warning :This OID indicates that the Gain is lower than the Warning theshold of the IL1 Module <Help> This alarm indicates if the IL1 gain is too … |
| 1.3.6.1.4.1.20044.62.2.3.1.41.2 | ScalarpmoailhcsAlmLineGainHighWarning | read-only | current | IL1 Gain High Warning :This OID indicates that the Gain is higher than the Warning threshold of the IL1 Module <Help> This alarm indicates if the IL1 gain is t… |
| 1.3.6.1.4.1.20044.62.2.3.1.41.3 | ScalarpmoailhcsAlmLineInputPwrLowWarning | read-only | current | IL1 Rx Pwr Low Warning :This OID indicates that the Receive Power is lower than the Warning theshold of the IL1 Optical Module <Help> This warning indicates if… |
| 1.3.6.1.4.1.20044.62.2.3.1.41.4 | ScalarpmoailhcsAlmLineInputPwrHighWarning | read-only | current | IL1 Rx Pwr High Warning :This OID indicates that the Receive Power is higher than the Warning theshold of the IL1 Optical Module <Help> This warning indicates … |
| 1.3.6.1.4.1.20044.62.2.3.1.41.5 | ScalarpmoailhcsAlmLineOutputPwrLowWarning | read-only | current | IL1 Tx Pwr Low Warning :This OID indicates that the Transmit Power is lower than the Warning theshold of the IL1 Optical Module <Help> This warning indicates i… |
| 1.3.6.1.4.1.20044.62.2.3.1.41.6 | ScalarpmoailhcsAlmLineOutputPwrHighWarning | read-only | current | IL1 Tx Pwr High Warning :This OID indicates that the Transmit Power is higher than the Warning theshold of the IL1 Optical Module <Help> This warning indicates… |
| 1.3.6.1.4.1.20044.62.2.3.1.41.7 | ScalarpmoailhcsAlmLineBiasLowWarning | read-only | current | IL1 Bias Low Warning :This OID indicates that the Bias is lower than the Warning theshold of the IL1 Optical Module <Help> This warning indicates if the IL1 bi… |
| 1.3.6.1.4.1.20044.62.2.3.1.41.8 | ScalarpmoailhcsAlmLineBiasHighWarning | read-only | current | IL1 Bias High Warning :This OID indicates that the Bias is higher than the Warning theshold of the IL1 Optical Module <Help> This warning indicates if the IL1 … |
| 1.3.6.1.4.1.20044.62.2.3.2 | NodepmoailhcsAlmLineUrg | |||
| 1.3.6.1.4.1.20044.62.2.3.2.40 | NodepmoailhcsAlmlineEdfaAlarms1 | |||
| 1.3.6.1.4.1.20044.62.2.3.2.40.1 | ScalarpmoailhcsAlmLineGainLowAlarm | read-only | current | IL1 Gain Low Alarm :This OID indicates that the Gain is lower than the alarm theshold of the IL1 Module <Help> This alarm indicates if the IL1 gain is too low … |
| 1.3.6.1.4.1.20044.62.2.3.2.40.2 | ScalarpmoailhcsAlmLineGainHighAlarm | read-only | current | IL1 Gain High Alarm :This OID indicates that the Gain is higher than the alarm threshold of the IL1 Module <Help> This alarm indicates if the IL1 gain is too h… |
| 1.3.6.1.4.1.20044.62.2.3.2.40.3 | ScalarpmoailhcsAlmLineInputPwrLowAlarm | read-only | current | IL1 Rx Pwr Low Alarm :This OID indicates that the Receive Power is lower than the alarm theshold of the IL1 Optical Module <Help> This alarm indicates if the I… |
| 1.3.6.1.4.1.20044.62.2.3.2.40.4 | ScalarpmoailhcsAlmLineInputPwrHighAlarm | read-only | current | IL1 Rx Pwr High Alarm :This OID indicates that the Receive Power is higher than the alarm theshold of the IL1 Optical Module <Help> This alarm indicates if the… |
| 1.3.6.1.4.1.20044.62.2.3.2.40.5 | ScalarpmoailhcsAlmLineOutputPwrLowAlarm | read-only | current | IL1 Tx Pwr Low Alarm :This OID indicates that the Transmit Power is lower than the alarm theshold of the IL1 Optical Module <Help> This alarm indicates if the … |
| 1.3.6.1.4.1.20044.62.2.3.2.40.6 | ScalarpmoailhcsAlmLineOutputPwrHighAlarm | read-only | current | IL1 Tx Pwr High Alarm :This OID indicates that the Transmit Power is higher than the alarm theshold of the IL1 Optical Module <Help> This alarm indicates if th… |
| 1.3.6.1.4.1.20044.62.2.3.2.40.7 | ScalarpmoailhcsAlmLineBiasLowAlarm | read-only | current | IL1 Bias Low Alarm :This OID indicates that the Bias is lower than the alarm theshold of the IL1 Optical Module <Help> This alarm indicates if the IL1 bias is … |
| 1.3.6.1.4.1.20044.62.2.3.2.40.8 | ScalarpmoailhcsAlmLineBiasHighAlarm | read-only | current | IL1 Bias High Alarm :This OID indicates that the Bias is higher than the alarm theshold of the IL1 Optical Module <Help> This alarm indicates if the IL1 bias i… |
| 1.3.6.1.4.1.20044.62.2.3.3 | NodepmoailhcsAlmLineCrit | |||
| 1.3.6.1.4.1.20044.62.2.3.3.7 | NodepmoailhcsAlmsynthAlm7 | |||
| 1.3.6.1.4.1.20044.62.2.3.3.7.4 | ScalarpmoailhcsAlmLineHwFail | read-only | current | Line Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Condtype> LINE_HW_FAIL <Probcause> equipmentMalfunction (1… |
| 1.3.6.1.4.1.20044.62.2.3.3.7.5 | ScalarpmoailhcsAlmLineTxOff | read-only | current | IL1 Optical Output Shutdown :This OID indicates the IL1 optical output power is on <Help> This status indicates if the IL1 laser pump is ON or OFF <Condtype> L… |
| 1.3.6.1.4.1.20044.62.2.3.3.7.12 | ScalarpmoailhcsAlmLineFail | read-only | current | Line Port Failure :This OID indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> callEstablishmentError(5) <Alarmtype> synthesisAlarm (12) <Po… |
| 1.3.6.1.4.1.20044.62.2.3.3.7.13 | ScalarpmoailhcsAlmLineExtPumpFail | read-only | current | IL1 External Pump Fail :This OID indicates that the external pump linked to the IL1 is in fail condition <Help> This alarm indicates if the external pump linke… |
| 1.3.6.1.4.1.20044.62.2.3.3.7.14 | ScalarpmoailhcsAlmSupvaFail | read-only | current | : <Condtype> SUPVA_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> equipmentAlarm (5) <Polarity> (2) |
| 1.3.6.1.4.1.20044.62.2.3.3.43 | NodepmoailhcsAlmlineEdfaAlarms2 | |||
| 1.3.6.1.4.1.20044.62.2.3.3.43.1 | ScalarpmoailhcsAlmLineEdfaNr | read-only | current | IL1 Optical Module Not Ready :This OID indicates that the IL1 Optical Module is not ready <Help> This status indicates if the IL1 has been correctly initialize… |
| 1.3.6.1.4.1.20044.62.2.3.3.43.2 | ScalarpmoailhcsAlmLineEdfaTecFail | read-only | current | IL1 TEC Fail :This OID indicates that the TEC is in fail condition on the IL1 Optical Module <Help> This alarm indicates if the TEC of the IL1 is in fail condi… |
| 1.3.6.1.4.1.20044.62.2.3.3.43.3 | ScalarpmoailhcsAlmLineEdfaLaserFail | read-only | current | IL1 Pump Laser Fail :This OID indicates a Transmit Laser Fail on the IL1 Optical Module <Help> This alarm indicates if the laser of the IL1 is in fail conditio… |
| 1.3.6.1.4.1.20044.62.2.3.3.43.4 | ScalarpmoailhcsAlmLineEdfaLos | read-only | current | IL1 Loss Of Signal :This OID indicates a Loss of Signal on the IL1 Optical Module <Help> This alarm indicates if an optical signal is detected on the IL1 input… |
| 1.3.6.1.4.1.20044.62.2.3.3.43.5 | ScalarpmoailhcsAlmLineExtPumpEdfaLowCurrent | read-only | current | IL1 Pump Low Current :This OID indicates that the EDFA pump current of IL1 is too low because of the external pump high power<Help> This alarm (only active whe… |
| 1.3.6.1.4.1.20044.62.2.3.3.43.6 | ScalarpmoailhcsAlmLineGainOutOfRange | read-only | current | IL1 Gain Out Of Range :This OID indicates the target gain of the IL2 is out of range (18-32dB), the flatness of the Booster is not guaranteed.<Help> This alarm… |
| 1.3.6.1.4.1.20044.62.2.3.3.45 | NodepmoailhcsAlmlineMsaAlarms | |||
| 1.3.6.1.4.1.20044.62.2.3.3.45.1 | ScalarpmoailhcsAlmLineMsaLos | read-only | current | IL1 MSA Loss Of Signal :This OID indicates a Loss of Signal is detected on the Mid Stage Access of the IL1 EDFAThis alarm indicates a Loss of Signal is detecte… |
| 1.3.6.1.4.1.20044.62.2.3.3.45.2 | ScalarpmoailhcsAlmLineMsaAttenuation | read-only | current | IL1 MSA Attenuation Alarm :This OID indicates the attenuation on the IL1 Mid Stage access has changed.This alarm indicates the attenuation on the IL2 Mid Stage… |
| 1.3.6.1.4.1.20044.62.2.3.3.48 | TablepmoailhcsAlmlineOscAlarmsTable | not-accessible | current | List of pmoailhcsAlmlineOscAlarms Article |
| 1.3.6.1.4.1.20044.62.2.3.3.48.1 | RowpmoailhcsAlmlineOscAlarmsEntry | not-accessible | current | Row definition for the pmoailhcsAlmlineOscAlarms table |
| 1.3.6.1.4.1.20044.62.2.3.3.48.1.1 | ColumnpmoailhcsAlmlineOscAlarmsIndex | read-only | current | Index definition for the pmoailhcsAlmlineOscAlarms table |
| 1.3.6.1.4.1.20044.62.2.3.3.48.1.2 | ColumnpmoailhcsAlmLineLosPortn | read-only | current | OSC Loss Of Signal :This OID indicates that no signal is present on the OSC <Help> This alarms indicates that no signal is present on the OSC <Condtype> LINE_L… |
| 1.3.6.1.4.1.20044.62.2.3.3.48.1.3 | ColumnpmoailhcsAlmLineTxOffPortn | read-only | current | OSC Optical Output Shutdown :This OID indicates the optical output power is shutdown on OSC<Help> This alarm indicates the optical output power is shutdown on … |
| 1.3.6.1.4.1.20044.62.2.3.3.48.1.4 | ColumnpmoailhcsAlmLineTxFailPortn | read-only | current | OSC Tx Fail :This OID indicates the OSC Laser is in fail condition<Help> This alarm indicates the OSC Laser is in fail condition <Condtype> LINE_TX_FAIL_1 <Pro… |
| 1.3.6.1.4.1.20044.62.2.3.3.48.1.5 | ColumnpmoailhcsAlmLineFecFailPortn | read-only | current | OSC FEC Fail :This OID indicates the FEC is in fail condition on the OSC input port<Help> This alarms indicates the FEC is in fail condition on the OSC input p… |
| 1.3.6.1.4.1.20044.62.2.3.3.48.1.6 | ColumnpmoailhcsAlmLineOosPortn | read-only | current | OSC In Service :This OID indicates that the OSC is In Service (1) or Out or Service (2)<Help> This status indicates that the OSC is In Service or Out or Servic… |
| 1.3.6.1.4.1.20044.62.2.3.3.48.1.7 | ColumnpmoailhcsAlmLineLofPortn | read-only | current | OSC Loss Of Frame : <Condtype> LINE_LOF_1 <Probcause> inputOutputDeviceError(24) <Alarmtype> equipmentAlarm (5) <Polarity> (2) |
| 1.3.6.1.4.1.20044.62.2.3.3.48.1.8 | ColumnpmoailhcsAlmLineOofPortn | read-only | current | OSC Out Of Frame : <Condtype> LINE_OOF_1 <Probcause> inputOutputDeviceError(24) <Alarmtype> equipmentAlarm (5) <Polarity> (2) |
| 1.3.6.1.4.1.20044.62.2.3.3.48.1.9 | ColumnpmoailhcsAlmLineRemoteTxFailPortn | read-only | current | OSC Remote Tx Fail : <Condtype> LINE_REMOTE_TX_FAIL_1 <Probcause> informationalStatus(1000) <Alarmtype> other(1) <Polarity> (2) |
| 1.3.6.1.4.1.20044.62.2.3.3.48.1.10 | ColumnpmoailhcsAlmLineWarningPortn | read-only | current | OSC DDM Warning :This OID indicates a warning is present on OSC Tx power, Receive power or temperature<Help> This alarm indicates a warning is present on OSC T… |
| 1.3.6.1.4.1.20044.62.2.3.3.48.1.11 | ColumnpmoailhcsAlmLineAlmPortn | read-only | current | OSC DDM Alarm :This alarm indicates an alarm is present on OSC Tx power, Rx power or temperature <Help> This alarm indicates an alarm is present on OSC Tx powe… |
| 1.3.6.1.4.1.20044.62.2.3.3.49 | TablepmoailhcsAlmlineOscThresholdAlarmsTable | not-accessible | current | List of pmoailhcsAlmlineOscThresholdAlarms Article |
| 1.3.6.1.4.1.20044.62.2.3.3.49.1 | RowpmoailhcsAlmlineOscThresholdAlarmsEntry | not-accessible | current | Row definition for the pmoailhcsAlmlineOscThresholdAlarms table |
| 1.3.6.1.4.1.20044.62.2.3.3.49.1.1 | ColumnpmoailhcsAlmlineOscThresholdAlarmsIndex | read-only | current | Index definition for the pmoailhcsAlmlineOscThresholdAlarms table |
| 1.3.6.1.4.1.20044.62.2.3.3.49.1.2 | ColumnpmoailhcsAlmLineTxPwrLowAlarmPortn | read-only | current | OSC Tx Power Low Alarm :This OID indicates the Tx Power of the OSC is lower than the warning threshold<Help> This alarm indicates the Tx Power of the OSC is lo… |
| 1.3.6.1.4.1.20044.62.2.3.3.49.1.3 | ColumnpmoailhcsAlmLineTxPwrHighAlarmPortn | read-only | current | OSC Tx Power High Alarm :This OID indicates the Tx Power of the OSC is higher than the warning threshold<Help> This alarm indicates the Tx Power of the OSC is … |
| 1.3.6.1.4.1.20044.62.2.3.3.49.1.4 | ColumnpmoailhcsAlmLineRxPwrLowAlarmPortn | read-only | current | OSC Rx Power Low Alarm :This OID indicates the Rx Power of the OSC is lower than the alarm threshold<Help> This alarm indicates the Rx Power of the OSC is lowe… |
| 1.3.6.1.4.1.20044.62.2.3.3.49.1.5 | ColumnpmoailhcsAlmLineRxPwrHighAlarmPortn | read-only | current | OSC Rx Power High Alarm :This OID indicates the Rx Power of the OSC is higher than the alarm threshold<Help> This alarm indicates the Rx Power of the OSC is hi… |
| 1.3.6.1.4.1.20044.62.2.3.3.49.1.6 | ColumnpmoailhcsAlmLineSpanlossLowAlarmPortn | read-only | current | OSC Span Loss Low Alarm :This OID indicates the OSC Span Loss is 3dB lower than the span loss reference<Help> This alarm indicates the OSC Span Loss is 3dB low… |
| 1.3.6.1.4.1.20044.62.2.3.3.49.1.7 | ColumnpmoailhcsAlmLineSpanlossHighAlarmPortn | read-only | current | OSC Span Loss High Alarm :This OID indicates the OSC Span Loss is 3dB higher than the span loss reference <Help> This alarm indicates the OSC Span Loss is 3dB … |
| 1.3.6.1.4.1.20044.62.2.3.3.49.1.8 | ColumnpmoailhcsAlmLineOscBiasLowAlarmPortn | read-only | current | OSC Bias Current Low Alarm :This OID indicates the OSC bias current is lower than the alarm threshold <Help> This alarm indicates the OSC bias current is lower… |
| 1.3.6.1.4.1.20044.62.2.3.3.49.1.9 | ColumnpmoailhcsAlmLineOscBiasHighAlarmPortn | read-only | current | OSC Bias Current High Alarm :This OID indicates the OSC bias current is higher than the alarm threshold <Help> This alarm indicates the OSC bias current is hig… |
| 1.3.6.1.4.1.20044.62.2.3.3.50 | TablepmoailhcsAlmlineOscThresholdsWarningsTable | not-accessible | current | List of pmoailhcsAlmlineOscThresholdsWarnings Article |
| 1.3.6.1.4.1.20044.62.2.3.3.50.1 | RowpmoailhcsAlmlineOscThresholdsWarningsEntry | not-accessible | current | Row definition for the pmoailhcsAlmlineOscThresholdsWarnings table |
| 1.3.6.1.4.1.20044.62.2.3.3.50.1.1 | ColumnpmoailhcsAlmlineOscThresholdsWarningsIndex | read-only | current | Index definition for the pmoailhcsAlmlineOscThresholdsWarnings table |
| 1.3.6.1.4.1.20044.62.2.3.3.50.1.2 | ColumnpmoailhcsAlmLineTxPwrLowWarningPortn | read-only | current | OSC Tx Power Low Warning :This OID indicates the Tx Power of the OSC is lower than the warning threshold<Help> This alarm indicates the Tx Power of the OSC is … |
| 1.3.6.1.4.1.20044.62.2.3.3.50.1.3 | ColumnpmoailhcsAlmLineTxPwrHighWarningPortn | read-only | current | OSC Tx Power High Warning :This OID indicates the Tx Power of the OSC is higher than the warning threshold<Help> This alarm indicates the Tx Power of the OSB i… |
| 1.3.6.1.4.1.20044.62.2.3.3.50.1.4 | ColumnpmoailhcsAlmLineRxPwrLowWarningPortn | read-only | current | OSC Rx Power Low Warning :This OID indicates the Rx Power of the OSC is lower than the warning threshold<Help> This alarm indicates the Tx Power of the OSC is … |
| 1.3.6.1.4.1.20044.62.2.3.3.50.1.5 | ColumnpmoailhcsAlmLineRxPwrHighWarningPortn | read-only | current | OSC Rx Power High Warning :This OID indicates the Rx Power of the OSC is higher than the warning threshold<Help> This alarm indicates the Rx Power of the OSC i… |
| 1.3.6.1.4.1.20044.62.2.3.3.50.1.6 | ColumnpmoailhcsAlmLineSpanlossLowWarningPortn | read-only | current | OSC Span Loss Low Warning :This OID indicates the OSC Span Loss is 1dB lower than the span loss reference<Help> This alarm indicates the OSC Span Loss is 1dB l… |
| 1.3.6.1.4.1.20044.62.2.3.3.50.1.7 | ColumnpmoailhcsAlmLineSpanlossHighWarningPortn | read-only | current | OSC Span Loss High Warning :This OID indicates the OSC Span Loss is 1dB higher than the span loss reference <Help> This alarm indicates the OSC Span Loss is 1d… |
| 1.3.6.1.4.1.20044.62.2.3.3.50.1.8 | ColumnpmoailhcsAlmLineOscBiasLowWarningPortn | read-only | current | OSC Bias Current Low Warning :This OID indicates the OSC bias current is lower than the warning threshold <Help> This alarm indicates the OSC bias current is l… |
| 1.3.6.1.4.1.20044.62.2.3.3.50.1.9 | ColumnpmoailhcsAlmLineOscBiasHighWarningPortn | read-only | current | OSC Bias Current High Warning :This OID indicates the OSC bias current is higher than the warning threshold <Help> This alarm indicates the OSC bias current is… |
| 1.3.6.1.4.1.20044.62.3 | Nodepmoailhcsmeasures | |||
| 1.3.6.1.4.1.20044.62.3.1 | NodepmoailhcsMesrOther | |||
| 1.3.6.1.4.1.20044.62.3.1.80 | ScalarpmoailhcsMesrtempMeas | read-only | current | Module Temperature :This OID gives the temperature of the PM (Temperature =AV/256) (Unit = C) <Help> This measure gives the temperature of the module |
| 1.3.6.1.4.1.20044.62.3.2 | NodepmoailhcsMesrClient | |||
| 1.3.6.1.4.1.20044.62.3.2.32 | ScalarpmoailhcsMesrclientEdfaBiasMeas | read-only | current | IL2 Pump Laser Current :This OID gives the pump laser current of the IL2 Optical Module (Current =AV/100) (Unit = mA) <Help> This measure gives the bias of the… |
| 1.3.6.1.4.1.20044.62.3.2.33 | ScalarpmoailhcsMesrclientEdfaTxpwrMeas | read-only | current | IL2 Tx Power :This OID gives the transmit power value of the IL2 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Tx optical… |
| 1.3.6.1.4.1.20044.62.3.2.34 | ScalarpmoailhcsMesrclientEdfaRxpwrMeas | read-only | current | IL2 Rx Power :This OID gives the receive power value of the IL2 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Rx optical … |
| 1.3.6.1.4.1.20044.62.3.2.35 | ScalarpmoailhcsMesrclientEdfaGainMeas | read-only | current | IL2 Gain Target :This OID gives the gain value of the IL2 Module (Gain =(AV-32768)*0,005) (Unit = dB) <Help> This information gives the target gain of the ampl… |
| 1.3.6.1.4.1.20044.62.3.2.36 | ScalarpmoailhcsMesrclientOscSpanLoss | read-only | current | IL2 Input Span Loss :This OID indicates the attenuation of the span connected to the IL2 input (Power =(AV-32768)*0,005) (Unit = dB) <Help> This measure indica… |
| 1.3.6.1.4.1.20044.62.3.2.37 | ScalarpmoailhcsMesrclientOscSpanLossRef | read-only | current | IL2 Input Span Loss Ref :This OID indicates the referenced attenuation of the span connected to the IL2 input (Used to monitor the variation of the span loss) … |
| 1.3.6.1.4.1.20044.62.3.2.38 | ScalarpmoailhcsMesrclientCorrectedGain | read-only | current | IL2 Gain :This OID gives the gain value of the IL2 Module corrected by the ASE compensation mechanism (Gain =(AV-32768)*0,005) (Unit = dB) <Help> This measure … |
| 1.3.6.1.4.1.20044.62.3.2.39 | ScalarpmoailhcsMesrclientMsaInputPower | read-only | current | IL2 MSA Rx Power :This OID indicates the input power of the Mid Stage Access of the IL2 (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure indicates th… |
| 1.3.6.1.4.1.20044.62.3.2.40 | ScalarpmoailhcsMesrclientMsaOutputPower | read-only | current | IL2 MSA Tx Power :This OID indicates the output power of the Mid Stage Access of the IL2 (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure indicates t… |
| 1.3.6.1.4.1.20044.62.3.2.41 | ScalarpmoailhcsMesrclientMsaAttenuation | read-only | current | IL2 MSA Attenuation :This OID indicates the attenuation applied on the Mid Stage Access of the IL2 (Attenuation =(AV-32768)*0,005) (Unit = dB) <Help> This meas… |
| 1.3.6.1.4.1.20044.62.3.2.42 | ScalarpmoailhcsMesrclientMsaAttenuationRef | read-only | current | IL2 MSA Attenuation Ref :This OID indicates the reference attenuation stored for the Mid Stage Access of the In-Line1 (Used to monitor the variation of this at… |
| 1.3.6.1.4.1.20044.62.3.3 | NodepmoailhcsMesrLine | |||
| 1.3.6.1.4.1.20044.62.3.3.48 | ScalarpmoailhcsMesrlineEdfaBiasMeas | read-only | current | IL1 Pump Laser Current :This OID gives the pump laser current of the IL1 Optical Module (Current =AV/100) (Unit = mA) <Help> This measure gives the bias of the… |
| 1.3.6.1.4.1.20044.62.3.3.49 | ScalarpmoailhcsMesrlineEdfaTxpwrMeas | read-only | current | IL1 Tx Power :This OID gives the transmit power value of the IL1 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Tx optical… |
| 1.3.6.1.4.1.20044.62.3.3.50 | ScalarpmoailhcsMesrlineEdfaRxpwrMeas | read-only | current | IL1 Rx Power :This OID gives the receive power value of the IL1 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Rx optical … |
| 1.3.6.1.4.1.20044.62.3.3.51 | ScalarpmoailhcsMesrlineEdfaGainMeas | read-only | current | IL1 Gain Target :This OID gives the gain value of the IL1 Module (Gain =(AV-32768)*0,005) (Unit = dB) <Help> This information gives the target gain of the ampl… |
| 1.3.6.1.4.1.20044.62.3.3.52 | ScalarpmoailhcsMesrlineOscSpanLoss | read-only | current | IL1 Input Span Loss :This OID indicates the attenuation of the span connected to the IL1 input (Power =(AV-32768)*0,005) (Unit = dB) <Help> This measure indica… |
| 1.3.6.1.4.1.20044.62.3.3.53 | ScalarpmoailhcsMesrlineOscSpanLossRef | read-only | current | IL1 Input Span Loss Ref :This OID indicates the referenced attenuation of the span connected to the IL1 input (Used to monitor the variation of the span loss) … |
| 1.3.6.1.4.1.20044.62.3.3.54 | ScalarpmoailhcsMesrlineCorrectedGain | read-only | current | IL1 Gain :This OID gives the gain value of the IL1 Module corrected by the ASE compensation mechanism (Gain =(AV-32768)*0,005) (Unit = dB) <Help> This measure … |
| 1.3.6.1.4.1.20044.62.3.3.55 | ScalarpmoailhcsMesrlineMsaInputPower | read-only | current | IL1 MSA Rx Power :This OID indicates the input power of the Mid Stage Access of the IL1 (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure indicates th… |
| 1.3.6.1.4.1.20044.62.3.3.56 | ScalarpmoailhcsMesrlineMsaOutputPower | read-only | current | IL1 MSA Tx Power :This OID indicates the output power of the Mid Stage Access of the IL1 (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure indicates t… |
| 1.3.6.1.4.1.20044.62.3.3.57 | ScalarpmoailhcsMesrlineMsaAttenuation | read-only | current | IL1 MSA Attenuation :This OID indicates the attenuation applied on the Mid Stage Access of the IL1 (Attenuation =(AV-32768)*0,005) (Unit = dB) <Help> This meas… |
| 1.3.6.1.4.1.20044.62.3.3.58 | ScalarpmoailhcsMesrlineMsaAttenuationRef | read-only | current | IL1 MSA Attenuation Ref :This OID indicates the reference attenuation stored for the Mid Stage Access of the IL1 (Used to monitor the variation of this attenua… |
| 1.3.6.1.4.1.20044.62.3.3.64 | TablepmoailhcsMesrlineOscTxPowerTable | not-accessible | current | List of pmoailhcsMesrlineOscTxPower Article |
| 1.3.6.1.4.1.20044.62.3.3.64.1 | RowpmoailhcsMesrlineOscTxPowerEntry | not-accessible | current | Row definition for the pmoailhcsMesrlineOscTxPower table |
| 1.3.6.1.4.1.20044.62.3.3.64.1.1 | ColumnpmoailhcsMesrlineOscTxPowerIndex | read-only | current | Index definition for the pmoailhcsMesrlineOscTxPower table |
| 1.3.6.1.4.1.20044.62.3.3.64.1.2 | ColumnpmoailhcsMesrlineOscTxPowerPortn | read-only | current | OSC Tx Power :This OID indicates the output power of the OSC (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure indicates the output power of the OSC |
| 1.3.6.1.4.1.20044.62.3.3.65 | TablepmoailhcsMesrlineOscRxPowerTable | not-accessible | current | List of pmoailhcsMesrlineOscRxPower Article |
| 1.3.6.1.4.1.20044.62.3.3.65.1 | RowpmoailhcsMesrlineOscRxPowerEntry | not-accessible | current | Row definition for the pmoailhcsMesrlineOscRxPower table |
| 1.3.6.1.4.1.20044.62.3.3.65.1.1 | ColumnpmoailhcsMesrlineOscRxPowerIndex | read-only | current | Index definition for the pmoailhcsMesrlineOscRxPower table |
| 1.3.6.1.4.1.20044.62.3.3.65.1.2 | ColumnpmoailhcsMesrlineOscRxPowerPortn | read-only | current | OSC Rx Power :This OID indicates the input power of the OSC (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure indicates the input power of the OSC |
| 1.3.6.1.4.1.20044.62.4 | Nodepmoailhcscounters | |||
| 1.3.6.1.4.1.20044.62.4.1 | NodepmoailhcsCntOther | |||
| 1.3.6.1.4.1.20044.62.4.2 | NodepmoailhcsCntClient | |||
| 1.3.6.1.4.1.20044.62.4.3 | NodepmoailhcsCntLine | |||
| 1.3.6.1.4.1.20044.62.4.3.16 | TablepmoailhcsCntlineOscErrTable | not-accessible | current | List of pmoailhcsCntlineOscErr Article |
| 1.3.6.1.4.1.20044.62.4.3.16.1 | RowpmoailhcsCntlineOscErrEntry | not-accessible | current | Row definition for the pmoailhcsCntlineOscErr table |
| 1.3.6.1.4.1.20044.62.4.3.16.1.1 | ColumnpmoailhcsCntlineOscErrIndex | read-only | current | Index definition for the pmoailhcsCntlineOscErr table |
| 1.3.6.1.4.1.20044.62.4.3.16.1.2 | ColumnpmoailhcsCntlineOscErrValuePortn | read-only | current | OSC FEC Counter :This OID indicates the number of errors corrected by the FEC of the OSC<Help> This measure indicates the number of errors corrected by the FEC… |
| 1.3.6.1.4.1.20044.62.4.3.16.1.3 | ColumnpmoailhcsCntlineOscErrErrorPortn | read-only | current | B1 Counter Error :This OID when set indicates the B1 counter value is invalid on Port |
| 1.3.6.1.4.1.20044.62.4.3.16.1.4 | ColumnpmoailhcsCntlineOscErrOverloadPortn | read-only | current | B1 Counter Overload :This OID when set indicates a B1 error counter overload on Port |
| 1.3.6.1.4.1.20044.62.4.259 | ScalarpmoailhcsCntCountersReset | read-write | current | Counters Reset:This OID resets and restarts all the counters |
| 1.3.6.1.4.1.20044.62.4.260 | ScalarpmoailhcsCntCountersStop | read-write | current | Counters stop:This OID stops all the counters |
| 1.3.6.1.4.1.20044.62.6 | NodepmoailhcscontrolsWrite | |||
| 1.3.6.1.4.1.20044.62.6.1 | NodepmoailhcsCtrlOther | |||
| 1.3.6.1.4.1.20044.62.6.1.0 | NodepmoailhcsCtrlsynth0 | |||
| 1.3.6.1.4.1.20044.62.6.1.0.1 | ScalarpmoailhcsCtrlConfLoad | read-write | current | Load Configuration Tables :When set this enables loading from flash configuration1 into the module. |
| 1.3.6.1.4.1.20044.62.6.1.0.9 | ScalarpmoailhcsCtrlConfFlash | read-write | current | Write Configuration Tables :This bit saves the current configuration of the module as configuration in the flash. <Help> This control saves the customer config… |
| 1.3.6.1.4.1.20044.62.6.1.0.13 | ScalarpmoailhcsCtrlConfClear | read-write | current | Clear Configuration Tables :This bit clears the configuration tables from configuration in the flash. <Help> This control restores the default configuration of… |
| 1.3.6.1.4.1.20044.62.6.1.5 | NodepmoailhcsCtrlswMgnt | |||
| 1.3.6.1.4.1.20044.62.6.1.5.2 | ScalarpmoailhcsCtrlColdReset | read-write | current | PM Cold Reset :This OID, when set, causes a cold reset of the Software. This reset is traffic affecting, and the configuration of Software is reloaded on start… |
| 1.3.6.1.4.1.20044.62.6.1.5.3 | ScalarpmoailhcsCtrlWarmReset | read-write | current | PM Warm Reset :This OID, when set, causes a warm reset of the Software. This reset is not traffic affecting, and the configuration of the Sofwtare remains unch… |
| 1.3.6.1.4.1.20044.62.6.1.73 | NodepmoailhcsCtrlledTest | |||
| 1.3.6.1.4.1.20044.62.6.1.73.1 | ScalarpmoailhcsCtrlGreenLed | read-write | current | Green Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green |
| 1.3.6.1.4.1.20044.62.6.1.73.2 | ScalarpmoailhcsCtrlRedLed | read-write | current | Red Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red |
| 1.3.6.1.4.1.20044.62.6.1.73.3 | ScalarpmoailhcsCtrlLedOff | read-write | current | Leds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF |
| 1.3.6.1.4.1.20044.62.6.1.75 | NodepmoailhcsCtrlmaintMode | |||
| 1.3.6.1.4.1.20044.62.6.1.75.1 | ScalarpmoailhcsCtrlMaintenance | read-write | current | PM Maintenance Mode :This OID sets the PM in maintenance mode <Help> This control enables the maintenance mode of the module |
| 1.3.6.1.4.1.20044.62.6.1.76 | NodepmoailhcsCtrlaprRestart | |||
| 1.3.6.1.4.1.20044.62.6.1.76.1 | ScalarpmoailhcsCtrlAprManualRestart | read-write | current | APR Manual Restart :This OID initiates the Restart mechanism to retrieve from the APR state.<Help> This control initiates the Restart mechanism to retrieve fro… |
| 1.3.6.1.4.1.20044.62.6.2 | NodepmoailhcsCtrlClient | |||
| 1.3.6.1.4.1.20044.62.6.2.33 | NodepmoailhcsCtrlclientOscInputSpanLoss | |||
| 1.3.6.1.4.1.20044.62.6.2.33.1 | ScalarpmoailhcsCtrlClientSpanLoss | read-write | current | Store IL2 Input Span Loss :This OID stores the current input span Loss as a reference to monitor the span loss variation <Help> This parameter stores the curre… |
| 1.3.6.1.4.1.20044.62.6.2.34 | ScalarpmoailhcsCtrlclientGainCstMonitorValue | read-write | current | IL2 Fiber Aging Period :This OID sets the value of the monitoring period to detect a fiber aging. (Unit = s) This value sets the monitoring period to detect a … |
| 1.3.6.1.4.1.20044.62.6.2.36 | ScalarpmoailhcsCtrlclientGainSettingValue | read-write | current | IL2 Gain Target :This OID sets the value of the nominal gain of the IL2lifier Module (active only in constant output power mode) (AV=(Gain/0,005) + 32768) (Uni… |
| 1.3.6.1.4.1.20044.62.6.2.37 | NodepmoailhcsCtrlclientGainProcessing | |||
| 1.3.6.1.4.1.20044.62.6.2.37.1 | ScalarpmoailhcsCtrlClientGainProc | read-write | current | IL2 Gain Adjustment :This OID initiates the automatic nominal gain adjustment on the IL2lifier Module<Help> This control initiates the automatic nominal gain a… |
| 1.3.6.1.4.1.20044.62.6.2.38 | ScalarpmoailhcsCtrlclientGainCstFiberAgingMarginValue | read-write | current | IL2 Aging Threshold :This OID sets the threshold to consider the power drop as a fiber aging. (active only in constant gain mode) (AV=(Gain/0,005) + 32768) (Un… |
| 1.3.6.1.4.1.20044.62.6.2.40 | NodepmoailhcsCtrlclientMsaAttenuationValue | |||
| 1.3.6.1.4.1.20044.62.6.2.40.1 | ScalarpmoailhcsCtrlClientAttenuation | read-write | current | Store IL2 MSA Attenuation :This OID stores the current attenuation applied on the Mid Stage Access of the IL2 (used for monitoring the MSA attenuation variatio… |
| 1.3.6.1.4.1.20044.62.6.3 | NodepmoailhcsCtrlLine | |||
| 1.3.6.1.4.1.20044.62.6.3.49 | NodepmoailhcsCtrllineOscInputSpanLoss | |||
| 1.3.6.1.4.1.20044.62.6.3.49.1 | ScalarpmoailhcsCtrlLineSpanLoss | read-write | current | Store IL1 Input Span Loss :This OID stores the current input span Loss as a reference to monitor the span loss variation<Help> This parameter stores the curren… |
| 1.3.6.1.4.1.20044.62.6.3.50 | ScalarpmoailhcsCtrllineGainCstMonitorValue | read-write | current | IL1 Fiber Aging Period :This OID sets the value of the monitoring period to detect a fiber aging. (Unit = s) This value sets the monitoring period to detect a … |
| 1.3.6.1.4.1.20044.62.6.3.52 | ScalarpmoailhcsCtrllineGainSettingValue | read-write | current | IL1 Gain Target :This OID sets the value of the nominal gain of the IL1 Module (active only in constant output power mode) (AV=(Gain/0,005) + 32768) (Unit = dB… |
| 1.3.6.1.4.1.20044.62.6.3.53 | NodepmoailhcsCtrllineGainProcessing | |||
| 1.3.6.1.4.1.20044.62.6.3.53.1 | ScalarpmoailhcsCtrlLineGainProc | read-write | current | IL1 Gain Adjustment :This OID initiates the automatic nominal gain adjustment on the IL1 Module<Help> This control initiates the automatic nominal gain adjustm… |
| 1.3.6.1.4.1.20044.62.6.3.54 | ScalarpmoailhcsCtrllineGainCstFiberAgingMarginValue | read-write | current | IL1 Aging Threshold :This OID sets the threshold to consider the power drop as a fiber aging. (active only in constant gain mode) (AV=(Gain/0,005) + 32768) (Un… |
| 1.3.6.1.4.1.20044.62.6.3.56 | NodepmoailhcsCtrllineMsaAttenuationValue | |||
| 1.3.6.1.4.1.20044.62.6.3.56.1 | ScalarpmoailhcsCtrlLineAttenuation | read-write | current | Store IL1 MSA Attenuation :This OID stores the current attenuation applied on the Mid Stage Access of the IL1 (used for monitoring the MSA attenuation variatio… |
| 1.3.6.1.4.1.20044.62.7 | Nodepmoailhcsri | |||
| 1.3.6.1.4.1.20044.62.7.2 | ScalarpmoailhcsRinvReloadInventory | read-write | current | Reload the inventory: This OID triggers an inventory reload. |
| 1.3.6.1.4.1.20044.62.7.3 | ScalarpmoailhcsRinvHwPlatform | read-only | current | HW platform description: This OID contains the description of the Hardware platform. |
| 1.3.6.1.4.1.20044.62.7.4 | ScalarpmoailhcsRinvModulePlatform | read-only | current | Module platform description: This OID contains the description of the Module. |
| 1.3.6.1.4.1.20044.62.7.5 | ScalarpmoailhcsRinvSwPlatform | read-only | current | SW platform description: This OID contains the description of the Software platform. |
| 1.3.6.1.4.1.20044.62.7.6 | ScalarpmoailhcsRinvGwPlatform | read-only | current | GW platform description: This OID contains the description of the gateware platform. |
| 1.3.6.1.4.1.20044.62.7.7 | TablepmoailhcsRinvBoosterTable | not-accessible | current | List of the Boosters on the selected module |
| 1.3.6.1.4.1.20044.62.7.7.1 | RowpmoailhcsRinvBoosterEntry | not-accessible | current | Row definition for the Boosters table |
| 1.3.6.1.4.1.20044.62.7.7.1.1 | ColumnpmoailhcsRinvBoosterIndex | read-only | current | Index for Booster table |
| 1.3.6.1.4.1.20044.62.7.7.1.2 | ColumnpmoailhcsRinvBooster | read-only | current | Inventory for the Booster: This OID contains the inventory for the Booster |
| 1.3.6.1.4.1.20044.62.7.8 | TablepmoailhcsRinvPreAmpTable | not-accessible | current | List of the PreAmps on the selected module |
| 1.3.6.1.4.1.20044.62.7.8.1 | RowpmoailhcsRinvPreAmpEntry | not-accessible | current | Row definition for the PreAmp table |
| 1.3.6.1.4.1.20044.62.7.8.1.1 | ColumnpmoailhcsRinvPreAmpIndex | read-only | current | Index for PreAmp table |
| 1.3.6.1.4.1.20044.62.7.8.1.2 | ColumnpmoailhcsRinvPreAmp | read-only | current | Inventory for the PreAmp: This OID contains the inventory for the PreAmp |
| 1.3.6.1.4.1.20044.62.9 | NodepmoailhcsConfig | |||
| 1.3.6.1.4.1.20044.62.9.1 | NodepmoailhcsCfgNoValue | |||
| 1.3.6.1.4.1.20044.62.9.1.1 | NodepmoailhcstableclientStartup | |||
| 1.3.6.1.4.1.20044.62.9.1.1.2 | ScalarpmoailhcsCfgclientEdfaLaserCtrl | read-write | current | Default Settings on Client Laser :This OID configures the default initialisation settings on the client laser. |
| 1.3.6.1.4.1.20044.62.9.1.1.3 | ScalarpmoailhcsCfgclientEdfaLaserMode | read-write | current | Default Settings on Client mode :This OID configures the default mode on the client amplifier. |
| 1.3.6.1.4.1.20044.62.9.1.1.4 | ScalarpmoailhcsCfgclientGainValue | read-write | current | Default Settings on Client Gain :This OID configures the default gain on the client amplifier. |
| 1.3.6.1.4.1.20044.62.9.1.1.5 | ScalarpmoailhcsCfgclientTiltValue | read-write | current | Default Settings on Client Tilt :This OID configures the default tilt on the client amplifier. |
| 1.3.6.1.4.1.20044.62.9.1.1.6 | ScalarpmoailhcsCfgclientMsaLoss | read-write | current | Default Settings on Client MSA :This OID configures the default MSA value on the client amplifier. |
| 1.3.6.1.4.1.20044.62.9.1.1.7 | ScalarpmoailhcsCfgclientOutputPowerValue | read-write | current | Default Settings on Client Output power :This OID configures the default Output power value on the client amplifier. |
| 1.3.6.1.4.1.20044.62.9.1.1.8 | ScalarpmoailhcsCfgclientAseCompensation | read-write | current | Default Settings on Client ASE :This OID configures the default ASE compensation value on the client amplifier. |
| 1.3.6.1.4.1.20044.62.9.2 | NodepmoailhcsCfgLineStartUp | |||
| 1.3.6.1.4.1.20044.62.9.2.1 | NodepmoailhcstablelineStartup | |||
| 1.3.6.1.4.1.20044.62.9.2.1.2 | ScalarpmoailhcsCfglineEdfaLaserCtrl | read-write | current | Default Settings on Line Laser :This OID configures the default initialisation settings on the line laser. |
| 1.3.6.1.4.1.20044.62.9.2.1.3 | ScalarpmoailhcsCfglineEdfaLaserMode | read-write | current | Default Settings on Line mode :This OID configures the default mode on the line amplifier. |
| 1.3.6.1.4.1.20044.62.9.2.1.4 | ScalarpmoailhcsCfglineGainValue | read-write | current | Default Settings on Line Gain :This OID configures the default gain on the line amplifier. |
| 1.3.6.1.4.1.20044.62.9.2.1.5 | ScalarpmoailhcsCfglineTiltValue | read-write | current | Default Settings on Line Tilt :This OID configures the default tilt on the line amplifier. |
| 1.3.6.1.4.1.20044.62.9.2.1.6 | ScalarpmoailhcsCfglineMsaLoss | read-write | current | Default Settings on Line MSA :This OID configures the default MSA value on the line amplifier. |
| 1.3.6.1.4.1.20044.62.9.2.1.7 | ScalarpmoailhcsCfglineOutputPowerValue | read-write | current | Default Settings on Line Output power :This OID configures the default Output power value on the line amplifier. |
| 1.3.6.1.4.1.20044.62.9.2.1.8 | ScalarpmoailhcsCfglineAseCompensation | read-write | current | Default Settings on Line ASE :This OID configures the default ASE compensation value on the line amplifier. |
| 1.3.6.1.4.1.20044.62.9.2.1.11 | ScalarpmoailhcsCfgaprMode | read-write | current | Default setting on module :This OID configures the default mode on the APR |
| 1.3.6.1.4.1.20044.62.9.3 | NodepmoailhcsCfgClientSupvStartUp | |||
| 1.3.6.1.4.1.20044.62.9.3.1 | TablepmoailhcsCfgLineStartupTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.62.9.3.1.1 | RowpmoailhcsCfgLineStartupEntry | not-accessible | current | Row definition for the clientSupvStartUp table |
| 1.3.6.1.4.1.20044.62.9.3.1.1.1 | ColumnpmoailhcsCfgLineStartupIndex | read-only | current | Index definition for the lineStartup table |
| 1.3.6.1.4.1.20044.62.9.3.1.1.3 | ColumnpmoailhcsCfgLineOscLaserCtrlPortn | read-write | current | Default Settings on OSC Laser :This OID configures the default initialisation settings on the OSC |
| 1.3.6.1.4.1.20044.62.9.3.1.1.4 | ColumnpmoailhcsCfgLineOscOosPortn | read-write | current | Default Settings on OSC mode :This OID configures the default mode on the OSC |
| 1.3.6.1.4.1.20044.62.9.3.1.1.5 | ColumnpmoailhcsCfgLineOscSpanLengthPortn | read-write | current | Default Settings on OSC span length :This OID defines the length of the span connected on the OSC port |
| 1.3.6.1.4.1.20044.62.9.3.1.1.6 | ColumnpmoailhcsCfgLineOscCorrectionFactorPortn | read-write | current | Default Settings on OSC attenuation corrector factor :This OID defines the correction factor to apply on the span attenuation measure on the OSC Channel (1510)… |
| 1.3.6.1.4.1.20044.62.9.4 | NodepmoailhcsCfgLabels | |||
| 1.3.6.1.4.1.20044.62.9.4.1 | TablepmoailhcsCfgLabelclientTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.62.9.4.1.1 | RowpmoailhcsCfgLabelclientEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.62.9.4.1.1.1 | ColumnpmoailhcsCfgLabelclientIndex | read-only | current | Index definition for the labelclient table |
| 1.3.6.1.4.1.20044.62.9.4.1.1.3 | ColumnpmoailhcsCfgLabelclientPortn | read-write | current | Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. |
| 1.3.6.1.4.1.20044.62.9.4.2 | TablepmoailhcsCfgLabellineTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.62.9.4.2.1 | RowpmoailhcsCfgLabellineEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.62.9.4.2.1.1 | ColumnpmoailhcsCfgLabellineIndex | read-only | current | Index definition for the labelline table |
| 1.3.6.1.4.1.20044.62.9.4.2.1.3 | ColumnpmoailhcsCfgLabellinePortn | read-write | current | Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. |
| 1.3.6.1.4.1.20044.62.9.257 | ScalarpmoailhcsCfgWriteConfiguration | read-write | current | Write configuration to module:This OID writes the complete configuration to the module |
| 1.3.6.1.4.1.20044.62.10 | Nodepmoailhcstraps | |||
| 1.3.6.1.4.1.20044.62.10.4 | ScalarpmoailhcstrapBoardNumber | read-only | current | Last module which generates a trap |
| 1.3.6.1.4.1.20044.62.10.34 | NotificationpmoailhcsLineTrapCritGoesOn | current | Critical Line default is activated | |
| 1.3.6.1.4.1.20044.62.10.35 | NotificationpmoailhcsLineTrapCritGoesOff | current | Critical Line default disappeared | |
| 1.3.6.1.4.1.20044.62.10.44 | NotificationpmoailhcsClientTrapCritGoesOn | current | Critical client default is activated | |
| 1.3.6.1.4.1.20044.62.10.45 | NotificationpmoailhcsClientTrapCritGoesOff | current | Critical client default disappeared | |
| 1.3.6.1.4.1.20044.62.10.50 | NotificationpmoailhcsPowerTrapUrgentGoesOn | current | Urgent power supply default is activated | |
| 1.3.6.1.4.1.20044.62.10.51 | NotificationpmoailhcsPowerTrapUrgentGoesOff | current | Urgent power supply default disappeared |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| PmoailhcsaprMode | INTEGER { oailhcsaproffmode(0), oailhcsaprsemiautomode(1), oailhcsaprautomode(2) oailhcsaprlossforwardingmode(3) oailhcsaprrepeatmode(4) } | current | Different modes on APR |
| PmoailhcsBoosterCstGainAdjMode | INTEGER { oailhcsboostercstgainadjsemiautomode(1), oailhcsboostercstgainadjautomode(2) } | current | Different modes when constant Gain |
| PmoailhcsBoosterGainAdjMode | INTEGER { oailhcsboostergainadjmanualmode(0), oailhcsboostergainadjsemiautomode(1), oailhcsboostergainadjautomode(2) } | current | Different modes on Gain |
| PmoailhcsboosterMode | INTEGER { oailhcsboosterdefaultmode(0), oailhcsboosterconstantcurrentmode(1), oailhcsboosterconstantpowermode(2) oailhcsboosterconstantgainmode(3) oailhcsboosterpoutpinmode(4) oailhcsboostermanualmode(5) oailhcsboosterfeedforwardmode(6) oailhcsboostertransientsupmode(7) } | current | Different modes on OA booster |
| PmoailhcsPreampCstGainAdjMode | INTEGER { oailhcspreampcstgainadjsemiautomode(1), oailhcspreampcstgainadjautomode(2) } | current | Different modes when constant Gain |
| PmoailhcsPreampGainAdjMode | INTEGER { oailhcspreampgainadjmanualmode(0), oailhcspreampgainadjsemiautomode(1), oailhcspreampgainadjautomode(2) } | current | Different modes on Gain |
| PmoailhcspreampMode | INTEGER { oailhcspreampdefaultmode(0), oailhcspreampconstantcurrentmode(1), oailhcspreampconstantpowermode(2) oailhcspreampconstantgainmode(3) oailhcspreamppoutpinmode(4) oailhcspreampmanualmode(5) oailhcspreampfeedforwardmode(6) oailhcspreamptransientsupmode(7) } | current | Different modes on OA preamp |