EKINOPS-Pmoailhcs-MIB

287 objects
Creation
OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.62IdentitymodulepmoailhcsCreation
1.3.6.1.4.1.20044.62.2Nodepmoailhcsalarms
1.3.6.1.4.1.20044.62.2.1NodepmoailhcsAlmOther
1.3.6.1.4.1.20044.62.2.1.1NodepmoailhcsAlmOtherNurg
1.3.6.1.4.1.20044.62.2.1.1.2NodepmoailhcsAlmsynthAlm2
1.3.6.1.4.1.20044.62.2.1.1.2.1ScalarpmoailhcsAlmConfTableSaveread-onlycurrentPM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> other…
1.3.6.1.4.1.20044.62.2.1.1.2.2ScalarpmoailhcsAlmInvUploadread-onlycurrentInventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> other (1) <Alarmtype> other (1) <Polarit…
1.3.6.1.4.1.20044.62.2.1.1.2.3ScalarpmoailhcsAlmConfTableLoadread-onlycurrentPM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> other (1) <Alarmt…
1.3.6.1.4.1.20044.62.2.1.1.75NodepmoailhcsAlmfoaWarnings
1.3.6.1.4.1.20044.62.2.1.1.75.7ScalarpmoailhcsAlmTermpLowWarningread-onlycurrentTemperature Low Warning :This OID indicates that the PM temperature if lower than the Warning threshold <Condtype> TERMP_LOW_WARNING <Probcause> temperatureUna…
1.3.6.1.4.1.20044.62.2.1.1.75.8ScalarpmoailhcsAlmTempHighWarningread-onlycurrentTemperature High Warning :This OID indicates that the PM temperature if higher than the Warning threshold <Condtype> TEMP_HIGH_WARNING <Probcause> temperatureU…
1.3.6.1.4.1.20044.62.2.1.2NodepmoailhcsAlmOtherUrg
1.3.6.1.4.1.20044.62.2.1.2.74NodepmoailhcsAlmfoaAlarms
1.3.6.1.4.1.20044.62.2.1.2.74.7ScalarpmoailhcsAlmTermpLowAlarmread-onlycurrentTemperature Low Alarm :This OID indicates that the PM temperature if lower than the alarm threshold <Condtype> TERMP_LOW_ALARM <Probcause> temperatureUnaccepta…
1.3.6.1.4.1.20044.62.2.1.2.74.8ScalarpmoailhcsAlmTempHighAlarmread-onlycurrentTemperature High Alarm :This OID indicates that the PM temperature is higher than the alarm threshold <Condtype> TEMP_HIGH_ALARM <Probcause> temperatureUnaccep…
1.3.6.1.4.1.20044.62.2.1.3NodepmoailhcsAlmOtherCrit
1.3.6.1.4.1.20044.62.2.1.3.0NodepmoailhcsAlmsynthAlm0
1.3.6.1.4.1.20044.62.2.1.3.0.1ScalarpmoailhcsAlmMaintenanceModeread-onlycurrentMaintenance Mode :This OID indicates that the PM is in maintenance mode <Help> This status indiates if the module is currently in maintenance mode <Condtype> M…
1.3.6.1.4.1.20044.62.2.1.3.0.2ScalarpmoailhcsAlmAprOnread-onlycurrentAutomatic Power Reduction :This OID indicates that the APR algorithm has been operated and the output of the lasers are shutdown <Help> The APR algorithm has b…
1.3.6.1.4.1.20044.62.2.1.3.0.9ScalarpmoailhcsAlmModGlobFailread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the PM <Condtype> MOD_GLOB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> sy…
1.3.6.1.4.1.20044.62.2.1.3.0.10ScalarpmoailhcsAlmUpEdfaInitNotComplread-onlycurrentIL1 Not Initialized :This OID indicates that the initialisation of the IL1 is not completed <Help> This status indicates if the IL1 has been correctly initiali…
1.3.6.1.4.1.20044.62.2.1.3.0.11ScalarpmoailhcsAlmDwEdfaInitNotComplread-onlycurrentIL2 Not Initialized :This OID indicates that the initialisation of the IL2 is not completed <Help> This status indicates if the IL2 has been correctly initiali…
1.3.6.1.4.1.20044.62.2.1.3.0.12ScalarpmoailhcsAlmExtPump1NotLockedread-onlycurrentExternal Pump Not Detected :This OID indicates that the first external pump is not detected by the amplifier module <Help> This alarm indicates if the external…
1.3.6.1.4.1.20044.62.2.1.3.0.15ScalarpmoailhcsAlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.62.2.1.3.0.16ScalarpmoailhcsAlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.62.2.2NodepmoailhcsAlmClient
1.3.6.1.4.1.20044.62.2.2.1NodepmoailhcsAlmClientNurg
1.3.6.1.4.1.20044.62.2.2.1.33NodepmoailhcsAlmclientEdfaWarnings
1.3.6.1.4.1.20044.62.2.2.1.33.1ScalarpmoailhcsAlmClientGainLowWarningread-onlycurrentIL2 Gain Low Warning :This OID indicates that the Gain is lower than the Warning theshold of the IL2 Module <Help> This alarm indicates if the IL2 gain is too …
1.3.6.1.4.1.20044.62.2.2.1.33.2ScalarpmoailhcsAlmClientGainHighWarningread-onlycurrentIL2 Gain High Warning :This OID indicates that the Gain is higher than the Warning threshold of the IL2 Module <Help> This alarm indicates if the IL2 gain is t…
1.3.6.1.4.1.20044.62.2.2.1.33.3ScalarpmoailhcsAlmClientInputPwrLowWarningread-onlycurrentIL2 Rx Pwr Low Warning :This OID indicates that the Receive Power is lower than the Warning theshold of the IL2 Optical Module <Help> This warning indicates if…
1.3.6.1.4.1.20044.62.2.2.1.33.4ScalarpmoailhcsAlmClientInputPwrHighWarningread-onlycurrentIL2 Rx Pwr High Warning :This OID indicates that the Receive Power is higher than the Warning theshold of the IL2 Optical Module <Help> This warning indicates …
1.3.6.1.4.1.20044.62.2.2.1.33.5ScalarpmoailhcsAlmClientOutputPwrLowWarningread-onlycurrentIL2 Tx Pwr Low Warning :This OID indicates that the Transmit Power is lower than the Warning theshold of the IL2 Optical Module <Help> This warning indicates i…
1.3.6.1.4.1.20044.62.2.2.1.33.6ScalarpmoailhcsAlmClientOutputPwrHighWarningread-onlycurrentIL2 Tx Pwr High Warning :This OID indicates that the Transmit Power is higher than the Warning theshold of the IL2 Optical Module <Help> This warning indicates…
1.3.6.1.4.1.20044.62.2.2.1.33.7ScalarpmoailhcsAlmClientBiasLowWarningread-onlycurrentIL2 Bias Low Warning :This OID indicates that the Bias is lower than the Warning theshold of the IL2 Optical Module <Help> This warning indicates if the IL2 bi…
1.3.6.1.4.1.20044.62.2.2.1.33.8ScalarpmoailhcsAlmClientBiasHighWarningread-onlycurrentIL2 Bias High Warning :This OID indicates that the Bias is higher than the Warning theshold of the IL2 Optical Module <Help> This warning indicates if the IL2 …
1.3.6.1.4.1.20044.62.2.2.2NodepmoailhcsAlmClientUrg
1.3.6.1.4.1.20044.62.2.2.2.32NodepmoailhcsAlmclientEdfaAlarms1
1.3.6.1.4.1.20044.62.2.2.2.32.1ScalarpmoailhcsAlmClientGainLowAlarmread-onlycurrentIL2 Gain Low Alarm :This OID indicates that the Gain is lower than the alarm theshold of the IL2 Module <Help> This alarm indicates if the IL2 gain is too low …
1.3.6.1.4.1.20044.62.2.2.2.32.2ScalarpmoailhcsAlmClientGainHighAlarmread-onlycurrentIL2 Gain High Alarm :This OID indicates that the Gain is higher than the alarm threshold of the IL2 Module <Help> This alarm indicates if the IL2 gain is too h…
1.3.6.1.4.1.20044.62.2.2.2.32.3ScalarpmoailhcsAlmClientInputPwrLowAlarmread-onlycurrentIL2 Rx Pwr Low Alarm :This OID indicates that the Receive Power is lower than the alarm theshold of the IL2 Optical Module <Help> This alarm indicates if the I…
1.3.6.1.4.1.20044.62.2.2.2.32.4ScalarpmoailhcsAlmClientInputPwrHighAlarmread-onlycurrentIL2 Rx Pwr High Alarm :This OID indicates that the Receive Power is higher than the alarm theshold of the IL2 Optical Module <Help> This alarm indicates if the…
1.3.6.1.4.1.20044.62.2.2.2.32.5ScalarpmoailhcsAlmClientOutputPwrLowAlarmread-onlycurrentIL2 Tx Pwr Low Alarm :This OID indicates that the Transmit Power is lower than the alarm theshold of the IL2 Optical Module <Help> This alarm indicates if the …
1.3.6.1.4.1.20044.62.2.2.2.32.6ScalarpmoailhcsAlmClientOutputPwrHighAlarmread-onlycurrentIL2 Tx Pwr High Alarm :This OID indicates that the Transmit Power is higher than the alarm theshold of the IL2 Optical Module <Help> This alarm indicates if th…
1.3.6.1.4.1.20044.62.2.2.2.32.7ScalarpmoailhcsAlmClientBiasLowAlarmread-onlycurrentIL2 Bias Low Alarm :This OID indicates that the Bias is lower than the alarm theshold of the IL2 Optical Module <Help> This alarm indicates if the IL2 bias is …
1.3.6.1.4.1.20044.62.2.2.2.32.8ScalarpmoailhcsAlmClientBiasHighAlarmread-onlycurrentIL2 Bias High Alarm :This OID indicates that the Bias is higher than the alarm theshold of the IL2 Optical Module <Help> This alarm indicates if the IL2 bias i…
1.3.6.1.4.1.20044.62.2.2.3NodepmoailhcsAlmClientCrit
1.3.6.1.4.1.20044.62.2.2.3.8NodepmoailhcsAlmsynthAlm8
1.3.6.1.4.1.20044.62.2.2.3.8.4ScalarpmoailhcsAlmClientHwFailread-onlycurrentClient Port HW Failure :This OID indicates a failure on Client port, most probably caused by a HW issue <Condtype> CLIENT_HW_FAIL <Probcause> equipmentMalfunct…
1.3.6.1.4.1.20044.62.2.2.3.8.5ScalarpmoailhcsAlmClientTxOffread-onlycurrentIL2 Optical Output Shutdown :This OID indicates the IL2 optical output power is on <Help> This status indicates if the IL2 laser pump transceiver laser is ON o…
1.3.6.1.4.1.20044.62.2.2.3.8.12ScalarpmoailhcsAlmClientFailread-onlycurrentClient Port Failure :This OID indicates a failure on the Client port <Condtype> CLIENT_FAIL <Probcause> bandwidthReduced(4) <Alarmtype> synthesisAlarm (12) <Po…
1.3.6.1.4.1.20044.62.2.2.3.8.13ScalarpmoailhcsAlmClientExtPumpFailread-onlycurrentIL2 External Pump Fail :This OID indicates that the external pump linked to the IL2 is in fail condition <Help> This alarm indicates if the external pump linke…
1.3.6.1.4.1.20044.62.2.2.3.8.14ScalarpmoailhcsAlmSupvbFailread-onlycurrent: <Condtype> SUPVB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> equipmentAlarm (5) <Polarity> (2)
1.3.6.1.4.1.20044.62.2.2.3.35NodepmoailhcsAlmclientEdfaAlarms2
1.3.6.1.4.1.20044.62.2.2.3.35.1ScalarpmoailhcsAlmClientEdfaNrread-onlycurrentIL2 Optical Module Not Ready :This OID indicates that the IL2 Optical Module is not ready <Help> This status indicates if the IL2 has been correctly initialize…
1.3.6.1.4.1.20044.62.2.2.3.35.2ScalarpmoailhcsAlmClientEdfaTecFailread-onlycurrentIL2 TEC Fail :This OID indicates that the TEC is in fail condition on the IL2 Optical Module <Help> This alarm indicates if the TEC of the IL2 is in fail condi…
1.3.6.1.4.1.20044.62.2.2.3.35.3ScalarpmoailhcsAlmClientEdfaLaserFailread-onlycurrentIL2 Pump Laser Fail :This OID indicates a Transmit Laser Fail on the IL2 Optical Module <Help> This alarm indicates if the laser of the IL2 is in fail conditio…
1.3.6.1.4.1.20044.62.2.2.3.35.4ScalarpmoailhcsAlmClientEdfaLosread-onlycurrentIL2 Loss Of Signal :This OID indicates a Loss of Signal on the IL2 Optical Module <Help> This alarm indicates if an optical signal is detected on the IL2 input…
1.3.6.1.4.1.20044.62.2.2.3.35.5ScalarpmoailhcsAlmClientExtPumpEdfaLowCurrentread-onlycurrentIL2 Pump Low Current :This OID indicates that the EDFA pump current of IL2 is too low because of the external pump high power<Help> This alarm (only active whe…
1.3.6.1.4.1.20044.62.2.2.3.35.6ScalarpmoailhcsAlmClientGainOutOfRangeread-onlycurrentIL2 Gain Out Of Range :This OID indicates the target gain of the IL2 is out of range (18-32dB), the flatness of the Booster is not guaranteed.<Help> This alarm…
1.3.6.1.4.1.20044.62.2.2.3.37NodepmoailhcsAlmclientMsaAlarms
1.3.6.1.4.1.20044.62.2.2.3.37.1ScalarpmoailhcsAlmClientMsaLosread-onlycurrentIL2 MSA Loss Of Signal :This OID indicates a Loss of Signal is detected on the Mid Stage Access of the IL2 EDFAThis alarm indicates a Loss of Signal is detecte…
1.3.6.1.4.1.20044.62.2.2.3.37.2ScalarpmoailhcsAlmClientMsaAttenuationread-onlycurrentIL2 MSA Attenuation Alarm :This OID indicates the attenuation on the IL2 Mid Stage access has changed.This alarm indicates the attenuation on the IL2 Mid Stage…
1.3.6.1.4.1.20044.62.2.3NodepmoailhcsAlmLine
1.3.6.1.4.1.20044.62.2.3.1NodepmoailhcsAlmLineNurg
1.3.6.1.4.1.20044.62.2.3.1.41NodepmoailhcsAlmlineEdfaWarnings
1.3.6.1.4.1.20044.62.2.3.1.41.1ScalarpmoailhcsAlmLineGainLowWarningread-onlycurrentIL1 Gain Low Warning :This OID indicates that the Gain is lower than the Warning theshold of the IL1 Module <Help> This alarm indicates if the IL1 gain is too …
1.3.6.1.4.1.20044.62.2.3.1.41.2ScalarpmoailhcsAlmLineGainHighWarningread-onlycurrentIL1 Gain High Warning :This OID indicates that the Gain is higher than the Warning threshold of the IL1 Module <Help> This alarm indicates if the IL1 gain is t…
1.3.6.1.4.1.20044.62.2.3.1.41.3ScalarpmoailhcsAlmLineInputPwrLowWarningread-onlycurrentIL1 Rx Pwr Low Warning :This OID indicates that the Receive Power is lower than the Warning theshold of the IL1 Optical Module <Help> This warning indicates if…
1.3.6.1.4.1.20044.62.2.3.1.41.4ScalarpmoailhcsAlmLineInputPwrHighWarningread-onlycurrentIL1 Rx Pwr High Warning :This OID indicates that the Receive Power is higher than the Warning theshold of the IL1 Optical Module <Help> This warning indicates …
1.3.6.1.4.1.20044.62.2.3.1.41.5ScalarpmoailhcsAlmLineOutputPwrLowWarningread-onlycurrentIL1 Tx Pwr Low Warning :This OID indicates that the Transmit Power is lower than the Warning theshold of the IL1 Optical Module <Help> This warning indicates i…
1.3.6.1.4.1.20044.62.2.3.1.41.6ScalarpmoailhcsAlmLineOutputPwrHighWarningread-onlycurrentIL1 Tx Pwr High Warning :This OID indicates that the Transmit Power is higher than the Warning theshold of the IL1 Optical Module <Help> This warning indicates…
1.3.6.1.4.1.20044.62.2.3.1.41.7ScalarpmoailhcsAlmLineBiasLowWarningread-onlycurrentIL1 Bias Low Warning :This OID indicates that the Bias is lower than the Warning theshold of the IL1 Optical Module <Help> This warning indicates if the IL1 bi…
1.3.6.1.4.1.20044.62.2.3.1.41.8ScalarpmoailhcsAlmLineBiasHighWarningread-onlycurrentIL1 Bias High Warning :This OID indicates that the Bias is higher than the Warning theshold of the IL1 Optical Module <Help> This warning indicates if the IL1 …
1.3.6.1.4.1.20044.62.2.3.2NodepmoailhcsAlmLineUrg
1.3.6.1.4.1.20044.62.2.3.2.40NodepmoailhcsAlmlineEdfaAlarms1
1.3.6.1.4.1.20044.62.2.3.2.40.1ScalarpmoailhcsAlmLineGainLowAlarmread-onlycurrentIL1 Gain Low Alarm :This OID indicates that the Gain is lower than the alarm theshold of the IL1 Module <Help> This alarm indicates if the IL1 gain is too low …
1.3.6.1.4.1.20044.62.2.3.2.40.2ScalarpmoailhcsAlmLineGainHighAlarmread-onlycurrentIL1 Gain High Alarm :This OID indicates that the Gain is higher than the alarm threshold of the IL1 Module <Help> This alarm indicates if the IL1 gain is too h…
1.3.6.1.4.1.20044.62.2.3.2.40.3ScalarpmoailhcsAlmLineInputPwrLowAlarmread-onlycurrentIL1 Rx Pwr Low Alarm :This OID indicates that the Receive Power is lower than the alarm theshold of the IL1 Optical Module <Help> This alarm indicates if the I…
1.3.6.1.4.1.20044.62.2.3.2.40.4ScalarpmoailhcsAlmLineInputPwrHighAlarmread-onlycurrentIL1 Rx Pwr High Alarm :This OID indicates that the Receive Power is higher than the alarm theshold of the IL1 Optical Module <Help> This alarm indicates if the…
1.3.6.1.4.1.20044.62.2.3.2.40.5ScalarpmoailhcsAlmLineOutputPwrLowAlarmread-onlycurrentIL1 Tx Pwr Low Alarm :This OID indicates that the Transmit Power is lower than the alarm theshold of the IL1 Optical Module <Help> This alarm indicates if the …
1.3.6.1.4.1.20044.62.2.3.2.40.6ScalarpmoailhcsAlmLineOutputPwrHighAlarmread-onlycurrentIL1 Tx Pwr High Alarm :This OID indicates that the Transmit Power is higher than the alarm theshold of the IL1 Optical Module <Help> This alarm indicates if th…
1.3.6.1.4.1.20044.62.2.3.2.40.7ScalarpmoailhcsAlmLineBiasLowAlarmread-onlycurrentIL1 Bias Low Alarm :This OID indicates that the Bias is lower than the alarm theshold of the IL1 Optical Module <Help> This alarm indicates if the IL1 bias is …
1.3.6.1.4.1.20044.62.2.3.2.40.8ScalarpmoailhcsAlmLineBiasHighAlarmread-onlycurrentIL1 Bias High Alarm :This OID indicates that the Bias is higher than the alarm theshold of the IL1 Optical Module <Help> This alarm indicates if the IL1 bias i…
1.3.6.1.4.1.20044.62.2.3.3NodepmoailhcsAlmLineCrit
1.3.6.1.4.1.20044.62.2.3.3.7NodepmoailhcsAlmsynthAlm7
1.3.6.1.4.1.20044.62.2.3.3.7.4ScalarpmoailhcsAlmLineHwFailread-onlycurrentLine Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Condtype> LINE_HW_FAIL <Probcause> equipmentMalfunction (1…
1.3.6.1.4.1.20044.62.2.3.3.7.5ScalarpmoailhcsAlmLineTxOffread-onlycurrentIL1 Optical Output Shutdown :This OID indicates the IL1 optical output power is on <Help> This status indicates if the IL1 laser pump is ON or OFF <Condtype> L…
1.3.6.1.4.1.20044.62.2.3.3.7.12ScalarpmoailhcsAlmLineFailread-onlycurrentLine Port Failure :This OID indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> callEstablishmentError(5) <Alarmtype> synthesisAlarm (12) <Po…
1.3.6.1.4.1.20044.62.2.3.3.7.13ScalarpmoailhcsAlmLineExtPumpFailread-onlycurrentIL1 External Pump Fail :This OID indicates that the external pump linked to the IL1 is in fail condition <Help> This alarm indicates if the external pump linke…
1.3.6.1.4.1.20044.62.2.3.3.7.14ScalarpmoailhcsAlmSupvaFailread-onlycurrent: <Condtype> SUPVA_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> equipmentAlarm (5) <Polarity> (2)
1.3.6.1.4.1.20044.62.2.3.3.43NodepmoailhcsAlmlineEdfaAlarms2
1.3.6.1.4.1.20044.62.2.3.3.43.1ScalarpmoailhcsAlmLineEdfaNrread-onlycurrentIL1 Optical Module Not Ready :This OID indicates that the IL1 Optical Module is not ready <Help> This status indicates if the IL1 has been correctly initialize…
1.3.6.1.4.1.20044.62.2.3.3.43.2ScalarpmoailhcsAlmLineEdfaTecFailread-onlycurrentIL1 TEC Fail :This OID indicates that the TEC is in fail condition on the IL1 Optical Module <Help> This alarm indicates if the TEC of the IL1 is in fail condi…
1.3.6.1.4.1.20044.62.2.3.3.43.3ScalarpmoailhcsAlmLineEdfaLaserFailread-onlycurrentIL1 Pump Laser Fail :This OID indicates a Transmit Laser Fail on the IL1 Optical Module <Help> This alarm indicates if the laser of the IL1 is in fail conditio…
1.3.6.1.4.1.20044.62.2.3.3.43.4ScalarpmoailhcsAlmLineEdfaLosread-onlycurrentIL1 Loss Of Signal :This OID indicates a Loss of Signal on the IL1 Optical Module <Help> This alarm indicates if an optical signal is detected on the IL1 input…
1.3.6.1.4.1.20044.62.2.3.3.43.5ScalarpmoailhcsAlmLineExtPumpEdfaLowCurrentread-onlycurrentIL1 Pump Low Current :This OID indicates that the EDFA pump current of IL1 is too low because of the external pump high power<Help> This alarm (only active whe…
1.3.6.1.4.1.20044.62.2.3.3.43.6ScalarpmoailhcsAlmLineGainOutOfRangeread-onlycurrentIL1 Gain Out Of Range :This OID indicates the target gain of the IL2 is out of range (18-32dB), the flatness of the Booster is not guaranteed.<Help> This alarm…
1.3.6.1.4.1.20044.62.2.3.3.45NodepmoailhcsAlmlineMsaAlarms
1.3.6.1.4.1.20044.62.2.3.3.45.1ScalarpmoailhcsAlmLineMsaLosread-onlycurrentIL1 MSA Loss Of Signal :This OID indicates a Loss of Signal is detected on the Mid Stage Access of the IL1 EDFAThis alarm indicates a Loss of Signal is detecte…
1.3.6.1.4.1.20044.62.2.3.3.45.2ScalarpmoailhcsAlmLineMsaAttenuationread-onlycurrentIL1 MSA Attenuation Alarm :This OID indicates the attenuation on the IL1 Mid Stage access has changed.This alarm indicates the attenuation on the IL2 Mid Stage…
1.3.6.1.4.1.20044.62.2.3.3.48TablepmoailhcsAlmlineOscAlarmsTablenot-accessiblecurrentList of pmoailhcsAlmlineOscAlarms Article
1.3.6.1.4.1.20044.62.2.3.3.48.1RowpmoailhcsAlmlineOscAlarmsEntrynot-accessiblecurrentRow definition for the pmoailhcsAlmlineOscAlarms table
1.3.6.1.4.1.20044.62.2.3.3.48.1.1ColumnpmoailhcsAlmlineOscAlarmsIndexread-onlycurrentIndex definition for the pmoailhcsAlmlineOscAlarms table
1.3.6.1.4.1.20044.62.2.3.3.48.1.2ColumnpmoailhcsAlmLineLosPortnread-onlycurrentOSC Loss Of Signal :This OID indicates that no signal is present on the OSC <Help> This alarms indicates that no signal is present on the OSC <Condtype> LINE_L…
1.3.6.1.4.1.20044.62.2.3.3.48.1.3ColumnpmoailhcsAlmLineTxOffPortnread-onlycurrentOSC Optical Output Shutdown :This OID indicates the optical output power is shutdown on OSC<Help> This alarm indicates the optical output power is shutdown on …
1.3.6.1.4.1.20044.62.2.3.3.48.1.4ColumnpmoailhcsAlmLineTxFailPortnread-onlycurrentOSC Tx Fail :This OID indicates the OSC Laser is in fail condition<Help> This alarm indicates the OSC Laser is in fail condition <Condtype> LINE_TX_FAIL_1 <Pro…
1.3.6.1.4.1.20044.62.2.3.3.48.1.5ColumnpmoailhcsAlmLineFecFailPortnread-onlycurrentOSC FEC Fail :This OID indicates the FEC is in fail condition on the OSC input port<Help> This alarms indicates the FEC is in fail condition on the OSC input p…
1.3.6.1.4.1.20044.62.2.3.3.48.1.6ColumnpmoailhcsAlmLineOosPortnread-onlycurrentOSC In Service :This OID indicates that the OSC is In Service (1) or Out or Service (2)<Help> This status indicates that the OSC is In Service or Out or Servic…
1.3.6.1.4.1.20044.62.2.3.3.48.1.7ColumnpmoailhcsAlmLineLofPortnread-onlycurrentOSC Loss Of Frame : <Condtype> LINE_LOF_1 <Probcause> inputOutputDeviceError(24) <Alarmtype> equipmentAlarm (5) <Polarity> (2)
1.3.6.1.4.1.20044.62.2.3.3.48.1.8ColumnpmoailhcsAlmLineOofPortnread-onlycurrentOSC Out Of Frame : <Condtype> LINE_OOF_1 <Probcause> inputOutputDeviceError(24) <Alarmtype> equipmentAlarm (5) <Polarity> (2)
1.3.6.1.4.1.20044.62.2.3.3.48.1.9ColumnpmoailhcsAlmLineRemoteTxFailPortnread-onlycurrentOSC Remote Tx Fail : <Condtype> LINE_REMOTE_TX_FAIL_1 <Probcause> informationalStatus(1000) <Alarmtype> other(1) <Polarity> (2)
1.3.6.1.4.1.20044.62.2.3.3.48.1.10ColumnpmoailhcsAlmLineWarningPortnread-onlycurrentOSC DDM Warning :This OID indicates a warning is present on OSC Tx power, Receive power or temperature<Help> This alarm indicates a warning is present on OSC T…
1.3.6.1.4.1.20044.62.2.3.3.48.1.11ColumnpmoailhcsAlmLineAlmPortnread-onlycurrentOSC DDM Alarm :This alarm indicates an alarm is present on OSC Tx power, Rx power or temperature <Help> This alarm indicates an alarm is present on OSC Tx powe…
1.3.6.1.4.1.20044.62.2.3.3.49TablepmoailhcsAlmlineOscThresholdAlarmsTablenot-accessiblecurrentList of pmoailhcsAlmlineOscThresholdAlarms Article
1.3.6.1.4.1.20044.62.2.3.3.49.1RowpmoailhcsAlmlineOscThresholdAlarmsEntrynot-accessiblecurrentRow definition for the pmoailhcsAlmlineOscThresholdAlarms table
1.3.6.1.4.1.20044.62.2.3.3.49.1.1ColumnpmoailhcsAlmlineOscThresholdAlarmsIndexread-onlycurrentIndex definition for the pmoailhcsAlmlineOscThresholdAlarms table
1.3.6.1.4.1.20044.62.2.3.3.49.1.2ColumnpmoailhcsAlmLineTxPwrLowAlarmPortnread-onlycurrentOSC Tx Power Low Alarm :This OID indicates the Tx Power of the OSC is lower than the warning threshold<Help> This alarm indicates the Tx Power of the OSC is lo…
1.3.6.1.4.1.20044.62.2.3.3.49.1.3ColumnpmoailhcsAlmLineTxPwrHighAlarmPortnread-onlycurrentOSC Tx Power High Alarm :This OID indicates the Tx Power of the OSC is higher than the warning threshold<Help> This alarm indicates the Tx Power of the OSC is …
1.3.6.1.4.1.20044.62.2.3.3.49.1.4ColumnpmoailhcsAlmLineRxPwrLowAlarmPortnread-onlycurrentOSC Rx Power Low Alarm :This OID indicates the Rx Power of the OSC is lower than the alarm threshold<Help> This alarm indicates the Rx Power of the OSC is lowe…
1.3.6.1.4.1.20044.62.2.3.3.49.1.5ColumnpmoailhcsAlmLineRxPwrHighAlarmPortnread-onlycurrentOSC Rx Power High Alarm :This OID indicates the Rx Power of the OSC is higher than the alarm threshold<Help> This alarm indicates the Rx Power of the OSC is hi…
1.3.6.1.4.1.20044.62.2.3.3.49.1.6ColumnpmoailhcsAlmLineSpanlossLowAlarmPortnread-onlycurrentOSC Span Loss Low Alarm :This OID indicates the OSC Span Loss is 3dB lower than the span loss reference<Help> This alarm indicates the OSC Span Loss is 3dB low…
1.3.6.1.4.1.20044.62.2.3.3.49.1.7ColumnpmoailhcsAlmLineSpanlossHighAlarmPortnread-onlycurrentOSC Span Loss High Alarm :This OID indicates the OSC Span Loss is 3dB higher than the span loss reference <Help> This alarm indicates the OSC Span Loss is 3dB …
1.3.6.1.4.1.20044.62.2.3.3.49.1.8ColumnpmoailhcsAlmLineOscBiasLowAlarmPortnread-onlycurrentOSC Bias Current Low Alarm :This OID indicates the OSC bias current is lower than the alarm threshold <Help> This alarm indicates the OSC bias current is lower…
1.3.6.1.4.1.20044.62.2.3.3.49.1.9ColumnpmoailhcsAlmLineOscBiasHighAlarmPortnread-onlycurrentOSC Bias Current High Alarm :This OID indicates the OSC bias current is higher than the alarm threshold <Help> This alarm indicates the OSC bias current is hig…
1.3.6.1.4.1.20044.62.2.3.3.50TablepmoailhcsAlmlineOscThresholdsWarningsTablenot-accessiblecurrentList of pmoailhcsAlmlineOscThresholdsWarnings Article
1.3.6.1.4.1.20044.62.2.3.3.50.1RowpmoailhcsAlmlineOscThresholdsWarningsEntrynot-accessiblecurrentRow definition for the pmoailhcsAlmlineOscThresholdsWarnings table
1.3.6.1.4.1.20044.62.2.3.3.50.1.1ColumnpmoailhcsAlmlineOscThresholdsWarningsIndexread-onlycurrentIndex definition for the pmoailhcsAlmlineOscThresholdsWarnings table
1.3.6.1.4.1.20044.62.2.3.3.50.1.2ColumnpmoailhcsAlmLineTxPwrLowWarningPortnread-onlycurrentOSC Tx Power Low Warning :This OID indicates the Tx Power of the OSC is lower than the warning threshold<Help> This alarm indicates the Tx Power of the OSC is …
1.3.6.1.4.1.20044.62.2.3.3.50.1.3ColumnpmoailhcsAlmLineTxPwrHighWarningPortnread-onlycurrentOSC Tx Power High Warning :This OID indicates the Tx Power of the OSC is higher than the warning threshold<Help> This alarm indicates the Tx Power of the OSB i…
1.3.6.1.4.1.20044.62.2.3.3.50.1.4ColumnpmoailhcsAlmLineRxPwrLowWarningPortnread-onlycurrentOSC Rx Power Low Warning :This OID indicates the Rx Power of the OSC is lower than the warning threshold<Help> This alarm indicates the Tx Power of the OSC is …
1.3.6.1.4.1.20044.62.2.3.3.50.1.5ColumnpmoailhcsAlmLineRxPwrHighWarningPortnread-onlycurrentOSC Rx Power High Warning :This OID indicates the Rx Power of the OSC is higher than the warning threshold<Help> This alarm indicates the Rx Power of the OSC i…
1.3.6.1.4.1.20044.62.2.3.3.50.1.6ColumnpmoailhcsAlmLineSpanlossLowWarningPortnread-onlycurrentOSC Span Loss Low Warning :This OID indicates the OSC Span Loss is 1dB lower than the span loss reference<Help> This alarm indicates the OSC Span Loss is 1dB l…
1.3.6.1.4.1.20044.62.2.3.3.50.1.7ColumnpmoailhcsAlmLineSpanlossHighWarningPortnread-onlycurrentOSC Span Loss High Warning :This OID indicates the OSC Span Loss is 1dB higher than the span loss reference <Help> This alarm indicates the OSC Span Loss is 1d…
1.3.6.1.4.1.20044.62.2.3.3.50.1.8ColumnpmoailhcsAlmLineOscBiasLowWarningPortnread-onlycurrentOSC Bias Current Low Warning :This OID indicates the OSC bias current is lower than the warning threshold <Help> This alarm indicates the OSC bias current is l…
1.3.6.1.4.1.20044.62.2.3.3.50.1.9ColumnpmoailhcsAlmLineOscBiasHighWarningPortnread-onlycurrentOSC Bias Current High Warning :This OID indicates the OSC bias current is higher than the warning threshold <Help> This alarm indicates the OSC bias current is…
1.3.6.1.4.1.20044.62.3Nodepmoailhcsmeasures
1.3.6.1.4.1.20044.62.3.1NodepmoailhcsMesrOther
1.3.6.1.4.1.20044.62.3.1.80ScalarpmoailhcsMesrtempMeasread-onlycurrentModule Temperature :This OID gives the temperature of the PM (Temperature =AV/256) (Unit = C) <Help> This measure gives the temperature of the module
1.3.6.1.4.1.20044.62.3.2NodepmoailhcsMesrClient
1.3.6.1.4.1.20044.62.3.2.32ScalarpmoailhcsMesrclientEdfaBiasMeasread-onlycurrentIL2 Pump Laser Current :This OID gives the pump laser current of the IL2 Optical Module (Current =AV/100) (Unit = mA) <Help> This measure gives the bias of the…
1.3.6.1.4.1.20044.62.3.2.33ScalarpmoailhcsMesrclientEdfaTxpwrMeasread-onlycurrentIL2 Tx Power :This OID gives the transmit power value of the IL2 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Tx optical…
1.3.6.1.4.1.20044.62.3.2.34ScalarpmoailhcsMesrclientEdfaRxpwrMeasread-onlycurrentIL2 Rx Power :This OID gives the receive power value of the IL2 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Rx optical …
1.3.6.1.4.1.20044.62.3.2.35ScalarpmoailhcsMesrclientEdfaGainMeasread-onlycurrentIL2 Gain Target :This OID gives the gain value of the IL2 Module (Gain =(AV-32768)*0,005) (Unit = dB) <Help> This information gives the target gain of the ampl…
1.3.6.1.4.1.20044.62.3.2.36ScalarpmoailhcsMesrclientOscSpanLossread-onlycurrentIL2 Input Span Loss :This OID indicates the attenuation of the span connected to the IL2 input (Power =(AV-32768)*0,005) (Unit = dB) <Help> This measure indica…
1.3.6.1.4.1.20044.62.3.2.37ScalarpmoailhcsMesrclientOscSpanLossRefread-onlycurrentIL2 Input Span Loss Ref :This OID indicates the referenced attenuation of the span connected to the IL2 input (Used to monitor the variation of the span loss) …
1.3.6.1.4.1.20044.62.3.2.38ScalarpmoailhcsMesrclientCorrectedGainread-onlycurrentIL2 Gain :This OID gives the gain value of the IL2 Module corrected by the ASE compensation mechanism (Gain =(AV-32768)*0,005) (Unit = dB) <Help> This measure …
1.3.6.1.4.1.20044.62.3.2.39ScalarpmoailhcsMesrclientMsaInputPowerread-onlycurrentIL2 MSA Rx Power :This OID indicates the input power of the Mid Stage Access of the IL2 (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure indicates th…
1.3.6.1.4.1.20044.62.3.2.40ScalarpmoailhcsMesrclientMsaOutputPowerread-onlycurrentIL2 MSA Tx Power :This OID indicates the output power of the Mid Stage Access of the IL2 (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure indicates t…
1.3.6.1.4.1.20044.62.3.2.41ScalarpmoailhcsMesrclientMsaAttenuationread-onlycurrentIL2 MSA Attenuation :This OID indicates the attenuation applied on the Mid Stage Access of the IL2 (Attenuation =(AV-32768)*0,005) (Unit = dB) <Help> This meas…
1.3.6.1.4.1.20044.62.3.2.42ScalarpmoailhcsMesrclientMsaAttenuationRefread-onlycurrentIL2 MSA Attenuation Ref :This OID indicates the reference attenuation stored for the Mid Stage Access of the In-Line1 (Used to monitor the variation of this at…
1.3.6.1.4.1.20044.62.3.3NodepmoailhcsMesrLine
1.3.6.1.4.1.20044.62.3.3.48ScalarpmoailhcsMesrlineEdfaBiasMeasread-onlycurrentIL1 Pump Laser Current :This OID gives the pump laser current of the IL1 Optical Module (Current =AV/100) (Unit = mA) <Help> This measure gives the bias of the…
1.3.6.1.4.1.20044.62.3.3.49ScalarpmoailhcsMesrlineEdfaTxpwrMeasread-onlycurrentIL1 Tx Power :This OID gives the transmit power value of the IL1 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Tx optical…
1.3.6.1.4.1.20044.62.3.3.50ScalarpmoailhcsMesrlineEdfaRxpwrMeasread-onlycurrentIL1 Rx Power :This OID gives the receive power value of the IL1 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Rx optical …
1.3.6.1.4.1.20044.62.3.3.51ScalarpmoailhcsMesrlineEdfaGainMeasread-onlycurrentIL1 Gain Target :This OID gives the gain value of the IL1 Module (Gain =(AV-32768)*0,005) (Unit = dB) <Help> This information gives the target gain of the ampl…
1.3.6.1.4.1.20044.62.3.3.52ScalarpmoailhcsMesrlineOscSpanLossread-onlycurrentIL1 Input Span Loss :This OID indicates the attenuation of the span connected to the IL1 input (Power =(AV-32768)*0,005) (Unit = dB) <Help> This measure indica…
1.3.6.1.4.1.20044.62.3.3.53ScalarpmoailhcsMesrlineOscSpanLossRefread-onlycurrentIL1 Input Span Loss Ref :This OID indicates the referenced attenuation of the span connected to the IL1 input (Used to monitor the variation of the span loss) …
1.3.6.1.4.1.20044.62.3.3.54ScalarpmoailhcsMesrlineCorrectedGainread-onlycurrentIL1 Gain :This OID gives the gain value of the IL1 Module corrected by the ASE compensation mechanism (Gain =(AV-32768)*0,005) (Unit = dB) <Help> This measure …
1.3.6.1.4.1.20044.62.3.3.55ScalarpmoailhcsMesrlineMsaInputPowerread-onlycurrentIL1 MSA Rx Power :This OID indicates the input power of the Mid Stage Access of the IL1 (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure indicates th…
1.3.6.1.4.1.20044.62.3.3.56ScalarpmoailhcsMesrlineMsaOutputPowerread-onlycurrentIL1 MSA Tx Power :This OID indicates the output power of the Mid Stage Access of the IL1 (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure indicates t…
1.3.6.1.4.1.20044.62.3.3.57ScalarpmoailhcsMesrlineMsaAttenuationread-onlycurrentIL1 MSA Attenuation :This OID indicates the attenuation applied on the Mid Stage Access of the IL1 (Attenuation =(AV-32768)*0,005) (Unit = dB) <Help> This meas…
1.3.6.1.4.1.20044.62.3.3.58ScalarpmoailhcsMesrlineMsaAttenuationRefread-onlycurrentIL1 MSA Attenuation Ref :This OID indicates the reference attenuation stored for the Mid Stage Access of the IL1 (Used to monitor the variation of this attenua…
1.3.6.1.4.1.20044.62.3.3.64TablepmoailhcsMesrlineOscTxPowerTablenot-accessiblecurrentList of pmoailhcsMesrlineOscTxPower Article
1.3.6.1.4.1.20044.62.3.3.64.1RowpmoailhcsMesrlineOscTxPowerEntrynot-accessiblecurrentRow definition for the pmoailhcsMesrlineOscTxPower table
1.3.6.1.4.1.20044.62.3.3.64.1.1ColumnpmoailhcsMesrlineOscTxPowerIndexread-onlycurrentIndex definition for the pmoailhcsMesrlineOscTxPower table
1.3.6.1.4.1.20044.62.3.3.64.1.2ColumnpmoailhcsMesrlineOscTxPowerPortnread-onlycurrentOSC Tx Power :This OID indicates the output power of the OSC (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure indicates the output power of the OSC
1.3.6.1.4.1.20044.62.3.3.65TablepmoailhcsMesrlineOscRxPowerTablenot-accessiblecurrentList of pmoailhcsMesrlineOscRxPower Article
1.3.6.1.4.1.20044.62.3.3.65.1RowpmoailhcsMesrlineOscRxPowerEntrynot-accessiblecurrentRow definition for the pmoailhcsMesrlineOscRxPower table
1.3.6.1.4.1.20044.62.3.3.65.1.1ColumnpmoailhcsMesrlineOscRxPowerIndexread-onlycurrentIndex definition for the pmoailhcsMesrlineOscRxPower table
1.3.6.1.4.1.20044.62.3.3.65.1.2ColumnpmoailhcsMesrlineOscRxPowerPortnread-onlycurrentOSC Rx Power :This OID indicates the input power of the OSC (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure indicates the input power of the OSC
1.3.6.1.4.1.20044.62.4Nodepmoailhcscounters
1.3.6.1.4.1.20044.62.4.1NodepmoailhcsCntOther
1.3.6.1.4.1.20044.62.4.2NodepmoailhcsCntClient
1.3.6.1.4.1.20044.62.4.3NodepmoailhcsCntLine
1.3.6.1.4.1.20044.62.4.3.16TablepmoailhcsCntlineOscErrTablenot-accessiblecurrentList of pmoailhcsCntlineOscErr Article
1.3.6.1.4.1.20044.62.4.3.16.1RowpmoailhcsCntlineOscErrEntrynot-accessiblecurrentRow definition for the pmoailhcsCntlineOscErr table
1.3.6.1.4.1.20044.62.4.3.16.1.1ColumnpmoailhcsCntlineOscErrIndexread-onlycurrentIndex definition for the pmoailhcsCntlineOscErr table
1.3.6.1.4.1.20044.62.4.3.16.1.2ColumnpmoailhcsCntlineOscErrValuePortnread-onlycurrentOSC FEC Counter :This OID indicates the number of errors corrected by the FEC of the OSC<Help> This measure indicates the number of errors corrected by the FEC…
1.3.6.1.4.1.20044.62.4.3.16.1.3ColumnpmoailhcsCntlineOscErrErrorPortnread-onlycurrentB1 Counter Error :This OID when set indicates the B1 counter value is invalid on Port
1.3.6.1.4.1.20044.62.4.3.16.1.4ColumnpmoailhcsCntlineOscErrOverloadPortnread-onlycurrentB1 Counter Overload :This OID when set indicates a B1 error counter overload on Port
1.3.6.1.4.1.20044.62.4.259ScalarpmoailhcsCntCountersResetread-writecurrentCounters Reset:This OID resets and restarts all the counters
1.3.6.1.4.1.20044.62.4.260ScalarpmoailhcsCntCountersStopread-writecurrentCounters stop:This OID stops all the counters
1.3.6.1.4.1.20044.62.6NodepmoailhcscontrolsWrite
1.3.6.1.4.1.20044.62.6.1NodepmoailhcsCtrlOther
1.3.6.1.4.1.20044.62.6.1.0NodepmoailhcsCtrlsynth0
1.3.6.1.4.1.20044.62.6.1.0.1ScalarpmoailhcsCtrlConfLoadread-writecurrentLoad Configuration Tables :When set this enables loading from flash configuration1 into the module.
1.3.6.1.4.1.20044.62.6.1.0.9ScalarpmoailhcsCtrlConfFlashread-writecurrentWrite Configuration Tables :This bit saves the current configuration of the module as configuration in the flash. <Help> This control saves the customer config…
1.3.6.1.4.1.20044.62.6.1.0.13ScalarpmoailhcsCtrlConfClearread-writecurrentClear Configuration Tables :This bit clears the configuration tables from configuration in the flash. <Help> This control restores the default configuration of…
1.3.6.1.4.1.20044.62.6.1.5NodepmoailhcsCtrlswMgnt
1.3.6.1.4.1.20044.62.6.1.5.2ScalarpmoailhcsCtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the Software. This reset is traffic affecting, and the configuration of Software is reloaded on start…
1.3.6.1.4.1.20044.62.6.1.5.3ScalarpmoailhcsCtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the Software. This reset is not traffic affecting, and the configuration of the Sofwtare remains unch…
1.3.6.1.4.1.20044.62.6.1.73NodepmoailhcsCtrlledTest
1.3.6.1.4.1.20044.62.6.1.73.1ScalarpmoailhcsCtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.62.6.1.73.2ScalarpmoailhcsCtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.62.6.1.73.3ScalarpmoailhcsCtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.62.6.1.75NodepmoailhcsCtrlmaintMode
1.3.6.1.4.1.20044.62.6.1.75.1ScalarpmoailhcsCtrlMaintenanceread-writecurrentPM Maintenance Mode :This OID sets the PM in maintenance mode <Help> This control enables the maintenance mode of the module
1.3.6.1.4.1.20044.62.6.1.76NodepmoailhcsCtrlaprRestart
1.3.6.1.4.1.20044.62.6.1.76.1ScalarpmoailhcsCtrlAprManualRestartread-writecurrentAPR Manual Restart :This OID initiates the Restart mechanism to retrieve from the APR state.<Help> This control initiates the Restart mechanism to retrieve fro…
1.3.6.1.4.1.20044.62.6.2NodepmoailhcsCtrlClient
1.3.6.1.4.1.20044.62.6.2.33NodepmoailhcsCtrlclientOscInputSpanLoss
1.3.6.1.4.1.20044.62.6.2.33.1ScalarpmoailhcsCtrlClientSpanLossread-writecurrentStore IL2 Input Span Loss :This OID stores the current input span Loss as a reference to monitor the span loss variation <Help> This parameter stores the curre…
1.3.6.1.4.1.20044.62.6.2.34ScalarpmoailhcsCtrlclientGainCstMonitorValueread-writecurrentIL2 Fiber Aging Period :This OID sets the value of the monitoring period to detect a fiber aging. (Unit = s) This value sets the monitoring period to detect a …
1.3.6.1.4.1.20044.62.6.2.36ScalarpmoailhcsCtrlclientGainSettingValueread-writecurrentIL2 Gain Target :This OID sets the value of the nominal gain of the IL2lifier Module (active only in constant output power mode) (AV=(Gain/0,005) + 32768) (Uni…
1.3.6.1.4.1.20044.62.6.2.37NodepmoailhcsCtrlclientGainProcessing
1.3.6.1.4.1.20044.62.6.2.37.1ScalarpmoailhcsCtrlClientGainProcread-writecurrentIL2 Gain Adjustment :This OID initiates the automatic nominal gain adjustment on the IL2lifier Module<Help> This control initiates the automatic nominal gain a…
1.3.6.1.4.1.20044.62.6.2.38ScalarpmoailhcsCtrlclientGainCstFiberAgingMarginValueread-writecurrentIL2 Aging Threshold :This OID sets the threshold to consider the power drop as a fiber aging. (active only in constant gain mode) (AV=(Gain/0,005) + 32768) (Un…
1.3.6.1.4.1.20044.62.6.2.40NodepmoailhcsCtrlclientMsaAttenuationValue
1.3.6.1.4.1.20044.62.6.2.40.1ScalarpmoailhcsCtrlClientAttenuationread-writecurrentStore IL2 MSA Attenuation :This OID stores the current attenuation applied on the Mid Stage Access of the IL2 (used for monitoring the MSA attenuation variatio…
1.3.6.1.4.1.20044.62.6.3NodepmoailhcsCtrlLine
1.3.6.1.4.1.20044.62.6.3.49NodepmoailhcsCtrllineOscInputSpanLoss
1.3.6.1.4.1.20044.62.6.3.49.1ScalarpmoailhcsCtrlLineSpanLossread-writecurrentStore IL1 Input Span Loss :This OID stores the current input span Loss as a reference to monitor the span loss variation<Help> This parameter stores the curren…
1.3.6.1.4.1.20044.62.6.3.50ScalarpmoailhcsCtrllineGainCstMonitorValueread-writecurrentIL1 Fiber Aging Period :This OID sets the value of the monitoring period to detect a fiber aging. (Unit = s) This value sets the monitoring period to detect a …
1.3.6.1.4.1.20044.62.6.3.52ScalarpmoailhcsCtrllineGainSettingValueread-writecurrentIL1 Gain Target :This OID sets the value of the nominal gain of the IL1 Module (active only in constant output power mode) (AV=(Gain/0,005) + 32768) (Unit = dB…
1.3.6.1.4.1.20044.62.6.3.53NodepmoailhcsCtrllineGainProcessing
1.3.6.1.4.1.20044.62.6.3.53.1ScalarpmoailhcsCtrlLineGainProcread-writecurrentIL1 Gain Adjustment :This OID initiates the automatic nominal gain adjustment on the IL1 Module<Help> This control initiates the automatic nominal gain adjustm…
1.3.6.1.4.1.20044.62.6.3.54ScalarpmoailhcsCtrllineGainCstFiberAgingMarginValueread-writecurrentIL1 Aging Threshold :This OID sets the threshold to consider the power drop as a fiber aging. (active only in constant gain mode) (AV=(Gain/0,005) + 32768) (Un…
1.3.6.1.4.1.20044.62.6.3.56NodepmoailhcsCtrllineMsaAttenuationValue
1.3.6.1.4.1.20044.62.6.3.56.1ScalarpmoailhcsCtrlLineAttenuationread-writecurrentStore IL1 MSA Attenuation :This OID stores the current attenuation applied on the Mid Stage Access of the IL1 (used for monitoring the MSA attenuation variatio…
1.3.6.1.4.1.20044.62.7Nodepmoailhcsri
1.3.6.1.4.1.20044.62.7.2ScalarpmoailhcsRinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.62.7.3ScalarpmoailhcsRinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.62.7.4ScalarpmoailhcsRinvModulePlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.62.7.5ScalarpmoailhcsRinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.62.7.6ScalarpmoailhcsRinvGwPlatformread-onlycurrentGW platform description: This OID contains the description of the gateware platform.
1.3.6.1.4.1.20044.62.7.7TablepmoailhcsRinvBoosterTablenot-accessiblecurrentList of the Boosters on the selected module
1.3.6.1.4.1.20044.62.7.7.1RowpmoailhcsRinvBoosterEntrynot-accessiblecurrentRow definition for the Boosters table
1.3.6.1.4.1.20044.62.7.7.1.1ColumnpmoailhcsRinvBoosterIndexread-onlycurrentIndex for Booster table
1.3.6.1.4.1.20044.62.7.7.1.2ColumnpmoailhcsRinvBoosterread-onlycurrentInventory for the Booster: This OID contains the inventory for the Booster
1.3.6.1.4.1.20044.62.7.8TablepmoailhcsRinvPreAmpTablenot-accessiblecurrentList of the PreAmps on the selected module
1.3.6.1.4.1.20044.62.7.8.1RowpmoailhcsRinvPreAmpEntrynot-accessiblecurrentRow definition for the PreAmp table
1.3.6.1.4.1.20044.62.7.8.1.1ColumnpmoailhcsRinvPreAmpIndexread-onlycurrentIndex for PreAmp table
1.3.6.1.4.1.20044.62.7.8.1.2ColumnpmoailhcsRinvPreAmpread-onlycurrentInventory for the PreAmp: This OID contains the inventory for the PreAmp
1.3.6.1.4.1.20044.62.9NodepmoailhcsConfig
1.3.6.1.4.1.20044.62.9.1NodepmoailhcsCfgNoValue
1.3.6.1.4.1.20044.62.9.1.1NodepmoailhcstableclientStartup
1.3.6.1.4.1.20044.62.9.1.1.2ScalarpmoailhcsCfgclientEdfaLaserCtrlread-writecurrentDefault Settings on Client Laser :This OID configures the default initialisation settings on the client laser.
1.3.6.1.4.1.20044.62.9.1.1.3ScalarpmoailhcsCfgclientEdfaLaserModeread-writecurrentDefault Settings on Client mode :This OID configures the default mode on the client amplifier.
1.3.6.1.4.1.20044.62.9.1.1.4ScalarpmoailhcsCfgclientGainValueread-writecurrentDefault Settings on Client Gain :This OID configures the default gain on the client amplifier.
1.3.6.1.4.1.20044.62.9.1.1.5ScalarpmoailhcsCfgclientTiltValueread-writecurrentDefault Settings on Client Tilt :This OID configures the default tilt on the client amplifier.
1.3.6.1.4.1.20044.62.9.1.1.6ScalarpmoailhcsCfgclientMsaLossread-writecurrentDefault Settings on Client MSA :This OID configures the default MSA value on the client amplifier.
1.3.6.1.4.1.20044.62.9.1.1.7ScalarpmoailhcsCfgclientOutputPowerValueread-writecurrentDefault Settings on Client Output power :This OID configures the default Output power value on the client amplifier.
1.3.6.1.4.1.20044.62.9.1.1.8ScalarpmoailhcsCfgclientAseCompensationread-writecurrentDefault Settings on Client ASE :This OID configures the default ASE compensation value on the client amplifier.
1.3.6.1.4.1.20044.62.9.2NodepmoailhcsCfgLineStartUp
1.3.6.1.4.1.20044.62.9.2.1NodepmoailhcstablelineStartup
1.3.6.1.4.1.20044.62.9.2.1.2ScalarpmoailhcsCfglineEdfaLaserCtrlread-writecurrentDefault Settings on Line Laser :This OID configures the default initialisation settings on the line laser.
1.3.6.1.4.1.20044.62.9.2.1.3ScalarpmoailhcsCfglineEdfaLaserModeread-writecurrentDefault Settings on Line mode :This OID configures the default mode on the line amplifier.
1.3.6.1.4.1.20044.62.9.2.1.4ScalarpmoailhcsCfglineGainValueread-writecurrentDefault Settings on Line Gain :This OID configures the default gain on the line amplifier.
1.3.6.1.4.1.20044.62.9.2.1.5ScalarpmoailhcsCfglineTiltValueread-writecurrentDefault Settings on Line Tilt :This OID configures the default tilt on the line amplifier.
1.3.6.1.4.1.20044.62.9.2.1.6ScalarpmoailhcsCfglineMsaLossread-writecurrentDefault Settings on Line MSA :This OID configures the default MSA value on the line amplifier.
1.3.6.1.4.1.20044.62.9.2.1.7ScalarpmoailhcsCfglineOutputPowerValueread-writecurrentDefault Settings on Line Output power :This OID configures the default Output power value on the line amplifier.
1.3.6.1.4.1.20044.62.9.2.1.8ScalarpmoailhcsCfglineAseCompensationread-writecurrentDefault Settings on Line ASE :This OID configures the default ASE compensation value on the line amplifier.
1.3.6.1.4.1.20044.62.9.2.1.11ScalarpmoailhcsCfgaprModeread-writecurrentDefault setting on module :This OID configures the default mode on the APR
1.3.6.1.4.1.20044.62.9.3NodepmoailhcsCfgClientSupvStartUp
1.3.6.1.4.1.20044.62.9.3.1TablepmoailhcsCfgLineStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.62.9.3.1.1RowpmoailhcsCfgLineStartupEntrynot-accessiblecurrentRow definition for the clientSupvStartUp table
1.3.6.1.4.1.20044.62.9.3.1.1.1ColumnpmoailhcsCfgLineStartupIndexread-onlycurrentIndex definition for the lineStartup table
1.3.6.1.4.1.20044.62.9.3.1.1.3ColumnpmoailhcsCfgLineOscLaserCtrlPortnread-writecurrentDefault Settings on OSC Laser :This OID configures the default initialisation settings on the OSC
1.3.6.1.4.1.20044.62.9.3.1.1.4ColumnpmoailhcsCfgLineOscOosPortnread-writecurrentDefault Settings on OSC mode :This OID configures the default mode on the OSC
1.3.6.1.4.1.20044.62.9.3.1.1.5ColumnpmoailhcsCfgLineOscSpanLengthPortnread-writecurrentDefault Settings on OSC span length :This OID defines the length of the span connected on the OSC port
1.3.6.1.4.1.20044.62.9.3.1.1.6ColumnpmoailhcsCfgLineOscCorrectionFactorPortnread-writecurrentDefault Settings on OSC attenuation corrector factor :This OID defines the correction factor to apply on the span attenuation measure on the OSC Channel (1510)…
1.3.6.1.4.1.20044.62.9.4NodepmoailhcsCfgLabels
1.3.6.1.4.1.20044.62.9.4.1TablepmoailhcsCfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.62.9.4.1.1RowpmoailhcsCfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.62.9.4.1.1.1ColumnpmoailhcsCfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.62.9.4.1.1.3ColumnpmoailhcsCfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.62.9.4.2TablepmoailhcsCfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.62.9.4.2.1RowpmoailhcsCfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.62.9.4.2.1.1ColumnpmoailhcsCfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.62.9.4.2.1.3ColumnpmoailhcsCfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.62.9.257ScalarpmoailhcsCfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.62.10Nodepmoailhcstraps
1.3.6.1.4.1.20044.62.10.4ScalarpmoailhcstrapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.62.10.34NotificationpmoailhcsLineTrapCritGoesOncurrentCritical Line default is activated
1.3.6.1.4.1.20044.62.10.35NotificationpmoailhcsLineTrapCritGoesOffcurrentCritical Line default disappeared
1.3.6.1.4.1.20044.62.10.44NotificationpmoailhcsClientTrapCritGoesOncurrentCritical client default is activated
1.3.6.1.4.1.20044.62.10.45NotificationpmoailhcsClientTrapCritGoesOffcurrentCritical client default disappeared
1.3.6.1.4.1.20044.62.10.50NotificationpmoailhcsPowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.62.10.51NotificationpmoailhcsPowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared
Type Definitions
NameSyntaxStatusDescription
PmoailhcsaprModeINTEGER { oailhcsaproffmode(0), oailhcsaprsemiautomode(1), oailhcsaprautomode(2) oailhcsaprlossforwardingmode(3) oailhcsaprrepeatmode(4) }currentDifferent modes on APR
PmoailhcsBoosterCstGainAdjModeINTEGER { oailhcsboostercstgainadjsemiautomode(1), oailhcsboostercstgainadjautomode(2) }currentDifferent modes when constant Gain
PmoailhcsBoosterGainAdjModeINTEGER { oailhcsboostergainadjmanualmode(0), oailhcsboostergainadjsemiautomode(1), oailhcsboostergainadjautomode(2) }currentDifferent modes on Gain
PmoailhcsboosterModeINTEGER { oailhcsboosterdefaultmode(0), oailhcsboosterconstantcurrentmode(1), oailhcsboosterconstantpowermode(2) oailhcsboosterconstantgainmode(3) oailhcsboosterpoutpinmode(4) oailhcsboostermanualmode(5) oailhcsboosterfeedforwardmode(6) oailhcsboostertransientsupmode(7) }currentDifferent modes on OA booster
PmoailhcsPreampCstGainAdjModeINTEGER { oailhcspreampcstgainadjsemiautomode(1), oailhcspreampcstgainadjautomode(2) }currentDifferent modes when constant Gain
PmoailhcsPreampGainAdjModeINTEGER { oailhcspreampgainadjmanualmode(0), oailhcspreampgainadjsemiautomode(1), oailhcspreampgainadjautomode(2) }currentDifferent modes on Gain
PmoailhcspreampModeINTEGER { oailhcspreampdefaultmode(0), oailhcspreampconstantcurrentmode(1), oailhcspreampconstantpowermode(2) oailhcspreampconstantgainmode(3) oailhcspreamppoutpinmode(4) oailhcspreampmanualmode(5) oailhcspreampfeedforwardmode(6) oailhcspreamptransientsupmode(7) }currentDifferent modes on OA preamp