EKINOPS-Pmopm2-MIB
1730 objects
MIB for managing Ekinops modules
Imported Objects
| EKINOPS-MIB | EkiApiState EkiMeasureType EkiMode ekinops EkiOnOff EkiProtocol EkiState EkiSynchroMode |
| SNMPv2-SMI | Counter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20044.64 | IdentitymodulePmopm2 | MIB for managing Ekinops modules | ||
| 1.3.6.1.4.1.20044.64.2 | Nodepmopm2alarms | |||
| 1.3.6.1.4.1.20044.64.2.1 | Nodepmopm2AlmOther | |||
| 1.3.6.1.4.1.20044.64.2.1.1 | Nodepmopm2AlmOtherNurg | |||
| 1.3.6.1.4.1.20044.64.2.1.1.2 | Nodepmopm2AlmsynthAlm2 | |||
| 1.3.6.1.4.1.20044.64.2.1.1.2.1 | Scalarpmopm2AlmConfTableSave | read-only | current | PM Configuration Save : <Condtype> CONF_TABLE_SAVE <Probcause> other (1) <Alarmtype> other (1) <Polarity> (2) |
| 1.3.6.1.4.1.20044.64.2.1.1.2.2 | Scalarpmopm2AlmInvUpload | read-only | current | Inventory Upload : <Condtype> INV_UPLOAD <Probcause> other (1) <Alarmtype> other (1) <Polarity> (2) |
| 1.3.6.1.4.1.20044.64.2.1.1.2.3 | Scalarpmopm2AlmConfTableLoad | read-only | current | PM Configuration Load : <Condtype> CONF_TABLE_LOAD <Probcause> other (1) <Alarmtype> other (1) <Polarity> (2) |
| 1.3.6.1.4.1.20044.64.2.1.1.2.4 | Scalarpmopm2AlmCorrelatOff | read-only | current | Not Used : <Condtype> CORRELAT_OFF <Probcause> other (1) <Alarmtype> other (1) <Polarity> (2) |
| 1.3.6.1.4.1.20044.64.2.1.2 | Nodepmopm2AlmOtherUrg | |||
| 1.3.6.1.4.1.20044.64.2.1.3 | Nodepmopm2AlmOtherCrit | |||
| 1.3.6.1.4.1.20044.64.2.1.3.0 | Nodepmopm2AlmsynthAlm0 | |||
| 1.3.6.1.4.1.20044.64.2.1.3.0.9 | Scalarpmopm2AlmModGlobFail | read-only | current | Module Failure :This OID is set on detection of a failure originating from the PM <Condtype> MOD_GLOB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> sy… |
| 1.3.6.1.4.1.20044.64.2.1.3.0.15 | Scalarpmopm2AlmDefFuseA | read-only | current | Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.64.2.1.3.0.16 | Scalarpmopm2AlmDefFuseB | read-only | current | Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.64.2.2 | Nodepmopm2AlmClient | |||
| 1.3.6.1.4.1.20044.64.2.2.1 | Nodepmopm2AlmClientNurg | |||
| 1.3.6.1.4.1.20044.64.2.2.2 | Nodepmopm2AlmClientUrg | |||
| 1.3.6.1.4.1.20044.64.2.2.3 | Nodepmopm2AlmClientCrit | |||
| 1.3.6.1.4.1.20044.64.2.2.3.8 | Tablepmopm2AlmsynthAlmPortTable | not-accessible | current | List of pmopm2AlmsynthAlmPort Article |
| 1.3.6.1.4.1.20044.64.2.2.3.8.1 | Rowpmopm2AlmsynthAlmPortEntry | not-accessible | current | Row definition for the pmopm2AlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.64.2.2.3.8.1.1 | Columnpmopm2AlmsynthAlmPortIndex | read-only | current | Index definition for the pmopm2AlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.64.2.2.3.8.1.2 | Columnpmopm2AlmSpectrumAbsentPortn | read-only | current | Spectrum Absent :This OID indicates there is no spectrum detected on the Optical Power Monitoring input<Help> This alarm indicates there is no spectrum detecte… |
| 1.3.6.1.4.1.20044.64.2.2.3.16 | Tablepmopm2Almchannel1PortTable | not-accessible | current | List of pmopm2Almchannel1Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.16.1 | Rowpmopm2Almchannel1PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel1Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.16.1.1 | Columnpmopm2Almchannel1PortIndex | read-only | current | Index definition for the pmopm2Almchannel1Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.16.1.2 | Columnpmopm2AlmChannel1AbsentPortn | read-only | current | Channel Absent :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service cha… |
| 1.3.6.1.4.1.20044.64.2.2.3.16.1.3 | Columnpmopm2AlmChannel1MismatchPortn | read-only | current | Channel Mismatch :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out of… |
| 1.3.6.1.4.1.20044.64.2.2.3.16.1.4 | Columnpmopm2AlmChannel1BalancedPortn | read-only | current | Channel Balanced :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in serv… |
| 1.3.6.1.4.1.20044.64.2.2.3.16.1.5 | Columnpmopm2AlmChannel1PowerLowPortn | read-only | current | Channel Power Low :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the cha… |
| 1.3.6.1.4.1.20044.64.2.2.3.16.1.6 | Columnpmopm2AlmChannel1PowerHighPortn | read-only | current | Channel Power High :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of the c… |
| 1.3.6.1.4.1.20044.64.2.2.3.16.1.7 | Columnpmopm2AlmChannel1OosPortn | read-only | current | Channel Out Of Service :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL1_OO… |
| 1.3.6.1.4.1.20044.64.2.2.3.18 | Tablepmopm2Almchannel2PortTable | not-accessible | current | List of pmopm2Almchannel2Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.18.1 | Rowpmopm2Almchannel2PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel2Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.18.1.1 | Columnpmopm2Almchannel2PortIndex | read-only | current | Index definition for the pmopm2Almchannel2Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.18.1.2 | Columnpmopm2AlmChannel2AbsentPortn | read-only | current | Channel Absent 2 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service c… |
| 1.3.6.1.4.1.20044.64.2.2.3.18.1.3 | Columnpmopm2AlmChannel2MismatchPortn | read-only | current | Channel Mismatch 2 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out … |
| 1.3.6.1.4.1.20044.64.2.2.3.18.1.4 | Columnpmopm2AlmChannel2BalancedPortn | read-only | current | Channel Balanced 2 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in se… |
| 1.3.6.1.4.1.20044.64.2.2.3.18.1.5 | Columnpmopm2AlmChannel2PowerLowPortn | read-only | current | Channel Power Low 2 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the c… |
| 1.3.6.1.4.1.20044.64.2.2.3.18.1.6 | Columnpmopm2AlmChannel2PowerHighPortn | read-only | current | Channel Power High 2 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of the… |
| 1.3.6.1.4.1.20044.64.2.2.3.18.1.7 | Columnpmopm2AlmChannel2OosPortn | read-only | current | Channel Out Of Service 2 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL2_… |
| 1.3.6.1.4.1.20044.64.2.2.3.20 | Tablepmopm2Almchannel3PortTable | not-accessible | current | List of pmopm2Almchannel3Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.20.1 | Rowpmopm2Almchannel3PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel3Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.20.1.1 | Columnpmopm2Almchannel3PortIndex | read-only | current | Index definition for the pmopm2Almchannel3Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.20.1.2 | Columnpmopm2AlmChannel3AbsentPortn | read-only | current | Channel Absent 3 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service c… |
| 1.3.6.1.4.1.20044.64.2.2.3.20.1.3 | Columnpmopm2AlmChannel3MismatchPortn | read-only | current | Channel Mismatch 3 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out … |
| 1.3.6.1.4.1.20044.64.2.2.3.20.1.4 | Columnpmopm2AlmChannel3BalancedPortn | read-only | current | Channel Balanced 3 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in se… |
| 1.3.6.1.4.1.20044.64.2.2.3.20.1.5 | Columnpmopm2AlmChannel3PowerLowPortn | read-only | current | Channel Power Low 3 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the c… |
| 1.3.6.1.4.1.20044.64.2.2.3.20.1.6 | Columnpmopm2AlmChannel3PowerHighPortn | read-only | current | Channel Power High 3 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of the… |
| 1.3.6.1.4.1.20044.64.2.2.3.20.1.7 | Columnpmopm2AlmChannel3OosPortn | read-only | current | Channel Out Of Service 3 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL3_… |
| 1.3.6.1.4.1.20044.64.2.2.3.22 | Tablepmopm2Almchannel4PortTable | not-accessible | current | List of pmopm2Almchannel4Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.22.1 | Rowpmopm2Almchannel4PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel4Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.22.1.1 | Columnpmopm2Almchannel4PortIndex | read-only | current | Index definition for the pmopm2Almchannel4Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.22.1.2 | Columnpmopm2AlmChannel4AbsentPortn | read-only | current | Channel Absent 4 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service c… |
| 1.3.6.1.4.1.20044.64.2.2.3.22.1.3 | Columnpmopm2AlmChannel4MismatchPortn | read-only | current | Channel Mismatch 4 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out … |
| 1.3.6.1.4.1.20044.64.2.2.3.22.1.4 | Columnpmopm2AlmChannel4BalancedPortn | read-only | current | Channel Balanced 4 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in se… |
| 1.3.6.1.4.1.20044.64.2.2.3.22.1.5 | Columnpmopm2AlmChannel4PowerLowPortn | read-only | current | Channel Power Low 4 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the c… |
| 1.3.6.1.4.1.20044.64.2.2.3.22.1.6 | Columnpmopm2AlmChannel4PowerHighPortn | read-only | current | Channel Power High 4 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of the… |
| 1.3.6.1.4.1.20044.64.2.2.3.22.1.7 | Columnpmopm2AlmChannel4OosPortn | read-only | current | Channel Out Of Service 4 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL4_… |
| 1.3.6.1.4.1.20044.64.2.2.3.24 | Tablepmopm2Almchannel5PortTable | not-accessible | current | List of pmopm2Almchannel5Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.24.1 | Rowpmopm2Almchannel5PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel5Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.24.1.1 | Columnpmopm2Almchannel5PortIndex | read-only | current | Index definition for the pmopm2Almchannel5Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.24.1.2 | Columnpmopm2AlmChannel5AbsentPortn | read-only | current | Channel Absent 5 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service c… |
| 1.3.6.1.4.1.20044.64.2.2.3.24.1.3 | Columnpmopm2AlmChannel5MismatchPortn | read-only | current | Channel Mismatch 5 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out … |
| 1.3.6.1.4.1.20044.64.2.2.3.24.1.4 | Columnpmopm2AlmChannel5BalancedPortn | read-only | current | Channel Balanced 5 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in se… |
| 1.3.6.1.4.1.20044.64.2.2.3.24.1.5 | Columnpmopm2AlmChannel5PowerLowPortn | read-only | current | Channel Power Low 5 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the c… |
| 1.3.6.1.4.1.20044.64.2.2.3.24.1.6 | Columnpmopm2AlmChannel5PowerHighPortn | read-only | current | Channel Power High 5 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of the… |
| 1.3.6.1.4.1.20044.64.2.2.3.24.1.7 | Columnpmopm2AlmChannel5OosPortn | read-only | current | Channel Out Of Service 5 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL5_… |
| 1.3.6.1.4.1.20044.64.2.2.3.26 | Tablepmopm2Almchannel6PortTable | not-accessible | current | List of pmopm2Almchannel6Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.26.1 | Rowpmopm2Almchannel6PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel6Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.26.1.1 | Columnpmopm2Almchannel6PortIndex | read-only | current | Index definition for the pmopm2Almchannel6Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.26.1.2 | Columnpmopm2AlmChannel6AbsentPortn | read-only | current | Channel Absent 6 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service c… |
| 1.3.6.1.4.1.20044.64.2.2.3.26.1.3 | Columnpmopm2AlmChannel6MismatchPortn | read-only | current | Channel Mismatch 6 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out … |
| 1.3.6.1.4.1.20044.64.2.2.3.26.1.4 | Columnpmopm2AlmChannel6BalancedPortn | read-only | current | Channel Balanced 6 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in se… |
| 1.3.6.1.4.1.20044.64.2.2.3.26.1.5 | Columnpmopm2AlmChannel6PowerLowPortn | read-only | current | Channel Power Low 6 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the c… |
| 1.3.6.1.4.1.20044.64.2.2.3.26.1.6 | Columnpmopm2AlmChannel6PowerHighPortn | read-only | current | Channel Power High 6 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of the… |
| 1.3.6.1.4.1.20044.64.2.2.3.26.1.7 | Columnpmopm2AlmChannel6OosPortn | read-only | current | Channel Out Of Service 6 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL6_… |
| 1.3.6.1.4.1.20044.64.2.2.3.28 | Tablepmopm2Almchannel7PortTable | not-accessible | current | List of pmopm2Almchannel7Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.28.1 | Rowpmopm2Almchannel7PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel7Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.28.1.1 | Columnpmopm2Almchannel7PortIndex | read-only | current | Index definition for the pmopm2Almchannel7Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.28.1.2 | Columnpmopm2AlmChannel7AbsentPortn | read-only | current | Channel Absent 7 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service c… |
| 1.3.6.1.4.1.20044.64.2.2.3.28.1.3 | Columnpmopm2AlmChannel7MismatchPortn | read-only | current | Channel Mismatch 7 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out … |
| 1.3.6.1.4.1.20044.64.2.2.3.28.1.4 | Columnpmopm2AlmChannel7BalancedPortn | read-only | current | Channel Balanced 7 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in se… |
| 1.3.6.1.4.1.20044.64.2.2.3.28.1.5 | Columnpmopm2AlmChannel7PowerLowPortn | read-only | current | Channel Power Low 7 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the c… |
| 1.3.6.1.4.1.20044.64.2.2.3.28.1.6 | Columnpmopm2AlmChannel7PowerHighPortn | read-only | current | Channel Power High 7 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of the… |
| 1.3.6.1.4.1.20044.64.2.2.3.28.1.7 | Columnpmopm2AlmChannel7OosPortn | read-only | current | Channel Out Of Service 7 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL7_… |
| 1.3.6.1.4.1.20044.64.2.2.3.30 | Tablepmopm2Almchannel8PortTable | not-accessible | current | List of pmopm2Almchannel8Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.30.1 | Rowpmopm2Almchannel8PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel8Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.30.1.1 | Columnpmopm2Almchannel8PortIndex | read-only | current | Index definition for the pmopm2Almchannel8Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.30.1.2 | Columnpmopm2AlmChannel8AbsentPortn | read-only | current | Channel Absent 8 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service c… |
| 1.3.6.1.4.1.20044.64.2.2.3.30.1.3 | Columnpmopm2AlmChannel8MismatchPortn | read-only | current | Channel Mismatch 8 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out … |
| 1.3.6.1.4.1.20044.64.2.2.3.30.1.4 | Columnpmopm2AlmChannel8BalancedPortn | read-only | current | Channel Balanced 8 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in se… |
| 1.3.6.1.4.1.20044.64.2.2.3.30.1.5 | Columnpmopm2AlmChannel8PowerLowPortn | read-only | current | Channel Power Low 8 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the c… |
| 1.3.6.1.4.1.20044.64.2.2.3.30.1.6 | Columnpmopm2AlmChannel8PowerHighPortn | read-only | current | Channel Power High 8 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of the… |
| 1.3.6.1.4.1.20044.64.2.2.3.30.1.7 | Columnpmopm2AlmChannel8OosPortn | read-only | current | Channel Out Of Service 8 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL8_… |
| 1.3.6.1.4.1.20044.64.2.2.3.32 | Tablepmopm2Almchannel9PortTable | not-accessible | current | List of pmopm2Almchannel9Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.32.1 | Rowpmopm2Almchannel9PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel9Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.32.1.1 | Columnpmopm2Almchannel9PortIndex | read-only | current | Index definition for the pmopm2Almchannel9Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.32.1.2 | Columnpmopm2AlmChannel9AbsentPortn | read-only | current | Channel Absent 9 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service c… |
| 1.3.6.1.4.1.20044.64.2.2.3.32.1.3 | Columnpmopm2AlmChannel9MismatchPortn | read-only | current | Channel Mismatch 9 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out … |
| 1.3.6.1.4.1.20044.64.2.2.3.32.1.4 | Columnpmopm2AlmChannel9BalancedPortn | read-only | current | Channel Balanced 9 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in se… |
| 1.3.6.1.4.1.20044.64.2.2.3.32.1.5 | Columnpmopm2AlmChannel9PowerLowPortn | read-only | current | Channel Power Low 9 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the c… |
| 1.3.6.1.4.1.20044.64.2.2.3.32.1.6 | Columnpmopm2AlmChannel9PowerHighPortn | read-only | current | Channel Power High 9 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of the… |
| 1.3.6.1.4.1.20044.64.2.2.3.32.1.7 | Columnpmopm2AlmChannel9OosPortn | read-only | current | Channel Out Of Service 9 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL9_… |
| 1.3.6.1.4.1.20044.64.2.2.3.34 | Tablepmopm2Almchannel10PortTable | not-accessible | current | List of pmopm2Almchannel10Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.34.1 | Rowpmopm2Almchannel10PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel10Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.34.1.1 | Columnpmopm2Almchannel10PortIndex | read-only | current | Index definition for the pmopm2Almchannel10Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.34.1.2 | Columnpmopm2AlmChannel10AbsentPortn | read-only | current | Channel Absent 10 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.34.1.3 | Columnpmopm2AlmChannel10MismatchPortn | read-only | current | Channel Mismatch 10 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.34.1.4 | Columnpmopm2AlmChannel10BalancedPortn | read-only | current | Channel Balanced 10 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.34.1.5 | Columnpmopm2AlmChannel10PowerLowPortn | read-only | current | Channel Power Low 10 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.34.1.6 | Columnpmopm2AlmChannel10PowerHighPortn | read-only | current | Channel Power High 10 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.34.1.7 | Columnpmopm2AlmChannel10OosPortn | read-only | current | Channel Out Of Service 10 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL1… |
| 1.3.6.1.4.1.20044.64.2.2.3.36 | Tablepmopm2Almchannel11PortTable | not-accessible | current | List of pmopm2Almchannel11Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.36.1 | Rowpmopm2Almchannel11PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel11Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.36.1.1 | Columnpmopm2Almchannel11PortIndex | read-only | current | Index definition for the pmopm2Almchannel11Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.36.1.2 | Columnpmopm2AlmChannel11AbsentPortn | read-only | current | Channel Absent 11 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.36.1.3 | Columnpmopm2AlmChannel11MismatchPortn | read-only | current | Channel Mismatch 11 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.36.1.4 | Columnpmopm2AlmChannel11BalancedPortn | read-only | current | Channel Balanced 11 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.36.1.5 | Columnpmopm2AlmChannel11PowerLowPortn | read-only | current | Channel Power Low 11 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.36.1.6 | Columnpmopm2AlmChannel11PowerHighPortn | read-only | current | Channel Power High 11 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.36.1.7 | Columnpmopm2AlmChannel11OosPortn | read-only | current | Channel Out Of Service 11 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL1… |
| 1.3.6.1.4.1.20044.64.2.2.3.38 | Tablepmopm2Almchannel12PortTable | not-accessible | current | List of pmopm2Almchannel12Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.38.1 | Rowpmopm2Almchannel12PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel12Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.38.1.1 | Columnpmopm2Almchannel12PortIndex | read-only | current | Index definition for the pmopm2Almchannel12Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.38.1.2 | Columnpmopm2AlmChannel12AbsentPortn | read-only | current | Channel Absent 12 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.38.1.3 | Columnpmopm2AlmChannel12MismatchPortn | read-only | current | Channel Mismatch 12 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.38.1.4 | Columnpmopm2AlmChannel12BalancedPortn | read-only | current | Channel Balanced 12 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.38.1.5 | Columnpmopm2AlmChannel12PowerLowPortn | read-only | current | Channel Power Low 12 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.38.1.6 | Columnpmopm2AlmChannel12PowerHighPortn | read-only | current | Channel Power High 12 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.38.1.7 | Columnpmopm2AlmChannel12OosPortn | read-only | current | Channel Out Of Service 12 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL1… |
| 1.3.6.1.4.1.20044.64.2.2.3.40 | Tablepmopm2Almchannel13PortTable | not-accessible | current | List of pmopm2Almchannel13Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.40.1 | Rowpmopm2Almchannel13PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel13Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.40.1.1 | Columnpmopm2Almchannel13PortIndex | read-only | current | Index definition for the pmopm2Almchannel13Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.40.1.2 | Columnpmopm2AlmChannel13AbsentPortn | read-only | current | Channel Absent 13 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.40.1.3 | Columnpmopm2AlmChannel13MismatchPortn | read-only | current | Channel Mismatch 13 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.40.1.4 | Columnpmopm2AlmChannel13BalancedPortn | read-only | current | Channel Balanced 13 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.40.1.5 | Columnpmopm2AlmChannel13PowerLowPortn | read-only | current | Channel Power Low 13 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.40.1.6 | Columnpmopm2AlmChannel13PowerHighPortn | read-only | current | Channel Power High 13 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.40.1.7 | Columnpmopm2AlmChannel13OosPortn | read-only | current | Channel Out Of Service 13 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL1… |
| 1.3.6.1.4.1.20044.64.2.2.3.42 | Tablepmopm2Almchannel14PortTable | not-accessible | current | List of pmopm2Almchannel14Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.42.1 | Rowpmopm2Almchannel14PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel14Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.42.1.1 | Columnpmopm2Almchannel14PortIndex | read-only | current | Index definition for the pmopm2Almchannel14Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.42.1.2 | Columnpmopm2AlmChannel14AbsentPortn | read-only | current | Channel Absent 14 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.42.1.3 | Columnpmopm2AlmChannel14MismatchPortn | read-only | current | Channel Mismatch 14 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.42.1.4 | Columnpmopm2AlmChannel14BalancedPortn | read-only | current | Channel Balanced 14 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.42.1.5 | Columnpmopm2AlmChannel14PowerLowPortn | read-only | current | Channel Power Low 14 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.42.1.6 | Columnpmopm2AlmChannel14PowerHighPortn | read-only | current | Channel Power High 14 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.42.1.7 | Columnpmopm2AlmChannel14OosPortn | read-only | current | Channel Out Of Service 14 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL1… |
| 1.3.6.1.4.1.20044.64.2.2.3.44 | Tablepmopm2Almchannel15PortTable | not-accessible | current | List of pmopm2Almchannel15Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.44.1 | Rowpmopm2Almchannel15PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel15Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.44.1.1 | Columnpmopm2Almchannel15PortIndex | read-only | current | Index definition for the pmopm2Almchannel15Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.44.1.2 | Columnpmopm2AlmChannel15AbsentPortn | read-only | current | Channel Absent 15 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.44.1.3 | Columnpmopm2AlmChannel15MismatchPortn | read-only | current | Channel Mismatch 15 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.44.1.4 | Columnpmopm2AlmChannel15BalancedPortn | read-only | current | Channel Balanced 15 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.44.1.5 | Columnpmopm2AlmChannel15PowerLowPortn | read-only | current | Channel Power Low 15 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.44.1.6 | Columnpmopm2AlmChannel15PowerHighPortn | read-only | current | Channel Power High 15 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.44.1.7 | Columnpmopm2AlmChannel15OosPortn | read-only | current | Channel Out Of Service 15 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL1… |
| 1.3.6.1.4.1.20044.64.2.2.3.46 | Tablepmopm2Almchannel16PortTable | not-accessible | current | List of pmopm2Almchannel16Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.46.1 | Rowpmopm2Almchannel16PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel16Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.46.1.1 | Columnpmopm2Almchannel16PortIndex | read-only | current | Index definition for the pmopm2Almchannel16Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.46.1.2 | Columnpmopm2AlmChannel16AbsentPortn | read-only | current | Channel Absent 16 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.46.1.3 | Columnpmopm2AlmChannel16MismatchPortn | read-only | current | Channel Mismatch 16 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.46.1.4 | Columnpmopm2AlmChannel16BalancedPortn | read-only | current | Channel Balanced 16 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.46.1.5 | Columnpmopm2AlmChannel16PowerLowPortn | read-only | current | Channel Power Low 16 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.46.1.6 | Columnpmopm2AlmChannel16PowerHighPortn | read-only | current | Channel Power High 16 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.46.1.7 | Columnpmopm2AlmChannel16OosPortn | read-only | current | Channel Out Of Service 16 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL1… |
| 1.3.6.1.4.1.20044.64.2.2.3.48 | Tablepmopm2Almchannel17PortTable | not-accessible | current | List of pmopm2Almchannel17Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.48.1 | Rowpmopm2Almchannel17PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel17Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.48.1.1 | Columnpmopm2Almchannel17PortIndex | read-only | current | Index definition for the pmopm2Almchannel17Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.48.1.2 | Columnpmopm2AlmChannel17AbsentPortn | read-only | current | Channel Absent 17 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.48.1.3 | Columnpmopm2AlmChannel17MismatchPortn | read-only | current | Channel Mismatch 17 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.48.1.4 | Columnpmopm2AlmChannel17BalancedPortn | read-only | current | Channel Balanced 17 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.48.1.5 | Columnpmopm2AlmChannel17PowerLowPortn | read-only | current | Channel Power Low 17 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.48.1.6 | Columnpmopm2AlmChannel17PowerHighPortn | read-only | current | Channel Power High 17 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.48.1.7 | Columnpmopm2AlmChannel17OosPortn | read-only | current | Channel Out Of Service 17 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL1… |
| 1.3.6.1.4.1.20044.64.2.2.3.50 | Tablepmopm2Almchannel18PortTable | not-accessible | current | List of pmopm2Almchannel18Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.50.1 | Rowpmopm2Almchannel18PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel18Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.50.1.1 | Columnpmopm2Almchannel18PortIndex | read-only | current | Index definition for the pmopm2Almchannel18Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.50.1.2 | Columnpmopm2AlmChannel18AbsentPortn | read-only | current | Channel Absent 18 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.50.1.3 | Columnpmopm2AlmChannel18MismatchPortn | read-only | current | Channel Mismatch 18 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.50.1.4 | Columnpmopm2AlmChannel18BalancedPortn | read-only | current | Channel Balanced 18 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.50.1.5 | Columnpmopm2AlmChannel18PowerLowPortn | read-only | current | Channel Power Low 18 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.50.1.6 | Columnpmopm2AlmChannel18PowerHighPortn | read-only | current | Channel Power High 18 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.50.1.7 | Columnpmopm2AlmChannel18OosPortn | read-only | current | Channel Out Of Service 18 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL1… |
| 1.3.6.1.4.1.20044.64.2.2.3.52 | Tablepmopm2Almchannel19PortTable | not-accessible | current | List of pmopm2Almchannel19Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.52.1 | Rowpmopm2Almchannel19PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel19Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.52.1.1 | Columnpmopm2Almchannel19PortIndex | read-only | current | Index definition for the pmopm2Almchannel19Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.52.1.2 | Columnpmopm2AlmChannel19AbsentPortn | read-only | current | Channel Absent 19 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.52.1.3 | Columnpmopm2AlmChannel19MismatchPortn | read-only | current | Channel Mismatch 19 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.52.1.4 | Columnpmopm2AlmChannel19BalancedPortn | read-only | current | Channel Balanced 19 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.52.1.5 | Columnpmopm2AlmChannel19PowerLowPortn | read-only | current | Channel Power Low 19 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.52.1.6 | Columnpmopm2AlmChannel19PowerHighPortn | read-only | current | Channel Power High 19 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.52.1.7 | Columnpmopm2AlmChannel19OosPortn | read-only | current | Channel Out Of Service 19 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL1… |
| 1.3.6.1.4.1.20044.64.2.2.3.54 | Tablepmopm2Almchannel20PortTable | not-accessible | current | List of pmopm2Almchannel20Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.54.1 | Rowpmopm2Almchannel20PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel20Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.54.1.1 | Columnpmopm2Almchannel20PortIndex | read-only | current | Index definition for the pmopm2Almchannel20Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.54.1.2 | Columnpmopm2AlmChannel20AbsentPortn | read-only | current | Channel Absent 20 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.54.1.3 | Columnpmopm2AlmChannel20MismatchPortn | read-only | current | Channel Mismatch 20 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.54.1.4 | Columnpmopm2AlmChannel20BalancedPortn | read-only | current | Channel Balanced 20 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.54.1.5 | Columnpmopm2AlmChannel20PowerLowPortn | read-only | current | Channel Power Low 20 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.54.1.6 | Columnpmopm2AlmChannel20PowerHighPortn | read-only | current | Channel Power High 20 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.54.1.7 | Columnpmopm2AlmChannel20OosPortn | read-only | current | Channel Out Of Service 20 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL2… |
| 1.3.6.1.4.1.20044.64.2.2.3.56 | Tablepmopm2Almchannel21PortTable | not-accessible | current | List of pmopm2Almchannel21Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.56.1 | Rowpmopm2Almchannel21PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel21Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.56.1.1 | Columnpmopm2Almchannel21PortIndex | read-only | current | Index definition for the pmopm2Almchannel21Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.56.1.2 | Columnpmopm2AlmChannel21AbsentPortn | read-only | current | Channel Absent 21 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.56.1.3 | Columnpmopm2AlmChannel21MismatchPortn | read-only | current | Channel Mismatch 21 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.56.1.4 | Columnpmopm2AlmChannel21BalancedPortn | read-only | current | Channel Balanced 21 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.56.1.5 | Columnpmopm2AlmChannel21PowerLowPortn | read-only | current | Channel Power Low 21 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.56.1.6 | Columnpmopm2AlmChannel21PowerHighPortn | read-only | current | Channel Power High 21 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.56.1.7 | Columnpmopm2AlmChannel21OosPortn | read-only | current | Channel Out Of Service 21 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL2… |
| 1.3.6.1.4.1.20044.64.2.2.3.58 | Tablepmopm2Almchannel22PortTable | not-accessible | current | List of pmopm2Almchannel22Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.58.1 | Rowpmopm2Almchannel22PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel22Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.58.1.1 | Columnpmopm2Almchannel22PortIndex | read-only | current | Index definition for the pmopm2Almchannel22Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.58.1.2 | Columnpmopm2AlmChannel22AbsentPortn | read-only | current | Channel Absent 22 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.58.1.3 | Columnpmopm2AlmChannel22MismatchPortn | read-only | current | Channel Mismatch 22 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.58.1.4 | Columnpmopm2AlmChannel22BalancedPortn | read-only | current | Channel Balanced 22 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.58.1.5 | Columnpmopm2AlmChannel22PowerLowPortn | read-only | current | Channel Power Low 22 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.58.1.6 | Columnpmopm2AlmChannel22PowerHighPortn | read-only | current | Channel Power High 22 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.58.1.7 | Columnpmopm2AlmChannel22OosPortn | read-only | current | Channel Out Of Service 22 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL2… |
| 1.3.6.1.4.1.20044.64.2.2.3.60 | Tablepmopm2Almchannel23PortTable | not-accessible | current | List of pmopm2Almchannel23Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.60.1 | Rowpmopm2Almchannel23PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel23Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.60.1.1 | Columnpmopm2Almchannel23PortIndex | read-only | current | Index definition for the pmopm2Almchannel23Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.60.1.2 | Columnpmopm2AlmChannel23AbsentPortn | read-only | current | Channel Absent 23 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.60.1.3 | Columnpmopm2AlmChannel23MismatchPortn | read-only | current | Channel Mismatch 23 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.60.1.4 | Columnpmopm2AlmChannel23BalancedPortn | read-only | current | Channel Balanced 23 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.60.1.5 | Columnpmopm2AlmChannel23PowerLowPortn | read-only | current | Channel Power Low 23 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.60.1.6 | Columnpmopm2AlmChannel23PowerHighPortn | read-only | current | Channel Power High 23 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.60.1.7 | Columnpmopm2AlmChannel23OosPortn | read-only | current | Channel Out Of Service 23 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL2… |
| 1.3.6.1.4.1.20044.64.2.2.3.62 | Tablepmopm2Almchannel24PortTable | not-accessible | current | List of pmopm2Almchannel24Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.62.1 | Rowpmopm2Almchannel24PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel24Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.62.1.1 | Columnpmopm2Almchannel24PortIndex | read-only | current | Index definition for the pmopm2Almchannel24Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.62.1.2 | Columnpmopm2AlmChannel24AbsentPortn | read-only | current | Channel Absent 24 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.62.1.3 | Columnpmopm2AlmChannel24MismatchPortn | read-only | current | Channel Mismatch 24 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.62.1.4 | Columnpmopm2AlmChannel24BalancedPortn | read-only | current | Channel Balanced 24 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.62.1.5 | Columnpmopm2AlmChannel24PowerLowPortn | read-only | current | Channel Power Low 24 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.62.1.6 | Columnpmopm2AlmChannel24PowerHighPortn | read-only | current | Channel Power High 24 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.62.1.7 | Columnpmopm2AlmChannel24OosPortn | read-only | current | Channel Out Of Service 24 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL2… |
| 1.3.6.1.4.1.20044.64.2.2.3.64 | Tablepmopm2Almchannel25PortTable | not-accessible | current | List of pmopm2Almchannel25Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.64.1 | Rowpmopm2Almchannel25PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel25Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.64.1.1 | Columnpmopm2Almchannel25PortIndex | read-only | current | Index definition for the pmopm2Almchannel25Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.64.1.2 | Columnpmopm2AlmChannel25AbsentPortn | read-only | current | Channel Absent 25 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.64.1.3 | Columnpmopm2AlmChannel25MismatchPortn | read-only | current | Channel Mismatch 25 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.64.1.4 | Columnpmopm2AlmChannel25BalancedPortn | read-only | current | Channel Balanced 25 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.64.1.5 | Columnpmopm2AlmChannel25PowerLowPortn | read-only | current | Channel Power Low 25 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.64.1.6 | Columnpmopm2AlmChannel25PowerHighPortn | read-only | current | Channel Power High 25 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.64.1.7 | Columnpmopm2AlmChannel25OosPortn | read-only | current | Channel Out Of Service 25 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL2… |
| 1.3.6.1.4.1.20044.64.2.2.3.66 | Tablepmopm2Almchannel26PortTable | not-accessible | current | List of pmopm2Almchannel26Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.66.1 | Rowpmopm2Almchannel26PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel26Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.66.1.1 | Columnpmopm2Almchannel26PortIndex | read-only | current | Index definition for the pmopm2Almchannel26Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.66.1.2 | Columnpmopm2AlmChannel26AbsentPortn | read-only | current | Channel Absent 26 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.66.1.3 | Columnpmopm2AlmChannel26MismatchPortn | read-only | current | Channel Mismatch 26 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.66.1.4 | Columnpmopm2AlmChannel26BalancedPortn | read-only | current | Channel Balanced 26 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.66.1.5 | Columnpmopm2AlmChannel26PowerLowPortn | read-only | current | Channel Power Low 26 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.66.1.6 | Columnpmopm2AlmChannel26PowerHighPortn | read-only | current | Channel Power High 26 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.66.1.7 | Columnpmopm2AlmChannel26OosPortn | read-only | current | Channel Out Of Service 26 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL2… |
| 1.3.6.1.4.1.20044.64.2.2.3.68 | Tablepmopm2Almchannel27PortTable | not-accessible | current | List of pmopm2Almchannel27Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.68.1 | Rowpmopm2Almchannel27PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel27Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.68.1.1 | Columnpmopm2Almchannel27PortIndex | read-only | current | Index definition for the pmopm2Almchannel27Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.68.1.2 | Columnpmopm2AlmChannel27AbsentPortn | read-only | current | Channel Absent 27 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.68.1.3 | Columnpmopm2AlmChannel27MismatchPortn | read-only | current | Channel Mismatch 27 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.68.1.4 | Columnpmopm2AlmChannel27BalancedPortn | read-only | current | Channel Balanced 27 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.68.1.5 | Columnpmopm2AlmChannel27PowerLowPortn | read-only | current | Channel Power Low 27 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.68.1.6 | Columnpmopm2AlmChannel27PowerHighPortn | read-only | current | Channel Power High 27 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.68.1.7 | Columnpmopm2AlmChannel27OosPortn | read-only | current | Channel Out Of Service 27 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL2… |
| 1.3.6.1.4.1.20044.64.2.2.3.70 | Tablepmopm2Almchannel28PortTable | not-accessible | current | List of pmopm2Almchannel28Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.70.1 | Rowpmopm2Almchannel28PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel28Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.70.1.1 | Columnpmopm2Almchannel28PortIndex | read-only | current | Index definition for the pmopm2Almchannel28Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.70.1.2 | Columnpmopm2AlmChannel28AbsentPortn | read-only | current | Channel Absent 28 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.70.1.3 | Columnpmopm2AlmChannel28MismatchPortn | read-only | current | Channel Mismatch 28 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.70.1.4 | Columnpmopm2AlmChannel28BalancedPortn | read-only | current | Channel Balanced 28 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.70.1.5 | Columnpmopm2AlmChannel28PowerLowPortn | read-only | current | Channel Power Low 28 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.70.1.6 | Columnpmopm2AlmChannel28PowerHighPortn | read-only | current | Channel Power High 28 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.70.1.7 | Columnpmopm2AlmChannel28OosPortn | read-only | current | Channel Out Of Service 28 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL2… |
| 1.3.6.1.4.1.20044.64.2.2.3.72 | Tablepmopm2Almchannel29PortTable | not-accessible | current | List of pmopm2Almchannel29Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.72.1 | Rowpmopm2Almchannel29PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel29Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.72.1.1 | Columnpmopm2Almchannel29PortIndex | read-only | current | Index definition for the pmopm2Almchannel29Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.72.1.2 | Columnpmopm2AlmChannel29AbsentPortn | read-only | current | Channel Absent 29 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.72.1.3 | Columnpmopm2AlmChannel29MismatchPortn | read-only | current | Channel Mismatch 29 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.72.1.4 | Columnpmopm2AlmChannel29BalancedPortn | read-only | current | Channel Balanced 29 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.72.1.5 | Columnpmopm2AlmChannel29PowerLowPortn | read-only | current | Channel Power Low 29 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.72.1.6 | Columnpmopm2AlmChannel29PowerHighPortn | read-only | current | Channel Power High 29 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.72.1.7 | Columnpmopm2AlmChannel29OosPortn | read-only | current | Channel Out Of Service 29 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL2… |
| 1.3.6.1.4.1.20044.64.2.2.3.74 | Tablepmopm2Almchannel30PortTable | not-accessible | current | List of pmopm2Almchannel30Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.74.1 | Rowpmopm2Almchannel30PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel30Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.74.1.1 | Columnpmopm2Almchannel30PortIndex | read-only | current | Index definition for the pmopm2Almchannel30Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.74.1.2 | Columnpmopm2AlmChannel30AbsentPortn | read-only | current | Channel Absent 30 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.74.1.3 | Columnpmopm2AlmChannel30MismatchPortn | read-only | current | Channel Mismatch 30 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.74.1.4 | Columnpmopm2AlmChannel30BalancedPortn | read-only | current | Channel Balanced 30 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.74.1.5 | Columnpmopm2AlmChannel30PowerLowPortn | read-only | current | Channel Power Low 30 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.74.1.6 | Columnpmopm2AlmChannel30PowerHighPortn | read-only | current | Channel Power High 30 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.74.1.7 | Columnpmopm2AlmChannel30OosPortn | read-only | current | Channel Out Of Service 30 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL3… |
| 1.3.6.1.4.1.20044.64.2.2.3.76 | Tablepmopm2Almchannel31PortTable | not-accessible | current | List of pmopm2Almchannel31Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.76.1 | Rowpmopm2Almchannel31PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel31Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.76.1.1 | Columnpmopm2Almchannel31PortIndex | read-only | current | Index definition for the pmopm2Almchannel31Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.76.1.2 | Columnpmopm2AlmChannel31AbsentPortn | read-only | current | Channel Absent 31 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.76.1.3 | Columnpmopm2AlmChannel31MismatchPortn | read-only | current | Channel Mismatch 31 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.76.1.4 | Columnpmopm2AlmChannel31BalancedPortn | read-only | current | Channel Balanced 31 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.76.1.5 | Columnpmopm2AlmChannel31PowerLowPortn | read-only | current | Channel Power Low 31 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.76.1.6 | Columnpmopm2AlmChannel31PowerHighPortn | read-only | current | Channel Power High 31 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.76.1.7 | Columnpmopm2AlmChannel31OosPortn | read-only | current | Channel Out Of Service 31 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL3… |
| 1.3.6.1.4.1.20044.64.2.2.3.78 | Tablepmopm2Almchannel32PortTable | not-accessible | current | List of pmopm2Almchannel32Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.78.1 | Rowpmopm2Almchannel32PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel32Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.78.1.1 | Columnpmopm2Almchannel32PortIndex | read-only | current | Index definition for the pmopm2Almchannel32Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.78.1.2 | Columnpmopm2AlmChannel32AbsentPortn | read-only | current | Channel Absent 32 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.78.1.3 | Columnpmopm2AlmChannel32MismatchPortn | read-only | current | Channel Mismatch 32 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.78.1.4 | Columnpmopm2AlmChannel32BalancedPortn | read-only | current | Channel Balanced 32 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.78.1.5 | Columnpmopm2AlmChannel32PowerLowPortn | read-only | current | Channel Power Low 32 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.78.1.6 | Columnpmopm2AlmChannel32PowerHighPortn | read-only | current | Channel Power High 32 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.78.1.7 | Columnpmopm2AlmChannel32OosPortn | read-only | current | Channel Out Of Service 32 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL3… |
| 1.3.6.1.4.1.20044.64.2.2.3.80 | Tablepmopm2Almchannel33PortTable | not-accessible | current | List of pmopm2Almchannel33Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.80.1 | Rowpmopm2Almchannel33PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel33Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.80.1.1 | Columnpmopm2Almchannel33PortIndex | read-only | current | Index definition for the pmopm2Almchannel33Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.80.1.2 | Columnpmopm2AlmChannel33AbsentPortn | read-only | current | Channel Absent 33 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.80.1.3 | Columnpmopm2AlmChannel33MismatchPortn | read-only | current | Channel Mismatch 33 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.80.1.4 | Columnpmopm2AlmChannel33BalancedPortn | read-only | current | Channel Balanced 33 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.80.1.5 | Columnpmopm2AlmChannel33PowerLowPortn | read-only | current | Channel Power Low 33 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.80.1.6 | Columnpmopm2AlmChannel33PowerHighPortn | read-only | current | Channel Power High 33 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.80.1.7 | Columnpmopm2AlmChannel33OosPortn | read-only | current | Channel Out Of Service 33 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL3… |
| 1.3.6.1.4.1.20044.64.2.2.3.82 | Tablepmopm2Almchannel34PortTable | not-accessible | current | List of pmopm2Almchannel34Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.82.1 | Rowpmopm2Almchannel34PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel34Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.82.1.1 | Columnpmopm2Almchannel34PortIndex | read-only | current | Index definition for the pmopm2Almchannel34Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.82.1.2 | Columnpmopm2AlmChannel34AbsentPortn | read-only | current | Channel Absent 34 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.82.1.3 | Columnpmopm2AlmChannel34MismatchPortn | read-only | current | Channel Mismatch 34 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.82.1.4 | Columnpmopm2AlmChannel34BalancedPortn | read-only | current | Channel Balanced 34 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.82.1.5 | Columnpmopm2AlmChannel34PowerLowPortn | read-only | current | Channel Power Low 34 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.82.1.6 | Columnpmopm2AlmChannel34PowerHighPortn | read-only | current | Channel Power High 34 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.82.1.7 | Columnpmopm2AlmChannel34OosPortn | read-only | current | Channel Out Of Service 34 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL3… |
| 1.3.6.1.4.1.20044.64.2.2.3.84 | Tablepmopm2Almchannel35PortTable | not-accessible | current | List of pmopm2Almchannel35Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.84.1 | Rowpmopm2Almchannel35PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel35Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.84.1.1 | Columnpmopm2Almchannel35PortIndex | read-only | current | Index definition for the pmopm2Almchannel35Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.84.1.2 | Columnpmopm2AlmChannel35AbsentPortn | read-only | current | Channel Absent 35 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.84.1.3 | Columnpmopm2AlmChannel35MismatchPortn | read-only | current | Channel Mismatch 35 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.84.1.4 | Columnpmopm2AlmChannel35BalancedPortn | read-only | current | Channel Balanced 35 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.84.1.5 | Columnpmopm2AlmChannel35PowerLowPortn | read-only | current | Channel Power Low 35 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.84.1.6 | Columnpmopm2AlmChannel35PowerHighPortn | read-only | current | Channel Power High 35 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.84.1.7 | Columnpmopm2AlmChannel35OosPortn | read-only | current | Channel Out Of Service 35 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL3… |
| 1.3.6.1.4.1.20044.64.2.2.3.86 | Tablepmopm2Almchannel36PortTable | not-accessible | current | List of pmopm2Almchannel36Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.86.1 | Rowpmopm2Almchannel36PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel36Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.86.1.1 | Columnpmopm2Almchannel36PortIndex | read-only | current | Index definition for the pmopm2Almchannel36Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.86.1.2 | Columnpmopm2AlmChannel36AbsentPortn | read-only | current | Channel Absent 36 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.86.1.3 | Columnpmopm2AlmChannel36MismatchPortn | read-only | current | Channel Mismatch 36 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.86.1.4 | Columnpmopm2AlmChannel36BalancedPortn | read-only | current | Channel Balanced 36 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.86.1.5 | Columnpmopm2AlmChannel36PowerLowPortn | read-only | current | Channel Power Low 36 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.86.1.6 | Columnpmopm2AlmChannel36PowerHighPortn | read-only | current | Channel Power High 36 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.86.1.7 | Columnpmopm2AlmChannel36OosPortn | read-only | current | Channel Out Of Service 36 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL3… |
| 1.3.6.1.4.1.20044.64.2.2.3.88 | Tablepmopm2Almchannel37PortTable | not-accessible | current | List of pmopm2Almchannel37Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.88.1 | Rowpmopm2Almchannel37PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel37Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.88.1.1 | Columnpmopm2Almchannel37PortIndex | read-only | current | Index definition for the pmopm2Almchannel37Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.88.1.2 | Columnpmopm2AlmChannel37AbsentPortn | read-only | current | Channel Absent 37 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.88.1.3 | Columnpmopm2AlmChannel37MismatchPortn | read-only | current | Channel Mismatch 37 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.88.1.4 | Columnpmopm2AlmChannel37BalancedPortn | read-only | current | Channel Balanced 37 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.88.1.5 | Columnpmopm2AlmChannel37PowerLowPortn | read-only | current | Channel Power Low 37 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.88.1.6 | Columnpmopm2AlmChannel37PowerHighPortn | read-only | current | Channel Power High 37 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.88.1.7 | Columnpmopm2AlmChannel37OosPortn | read-only | current | Channel Out Of Service 37 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL3… |
| 1.3.6.1.4.1.20044.64.2.2.3.90 | Tablepmopm2Almchannel38PortTable | not-accessible | current | List of pmopm2Almchannel38Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.90.1 | Rowpmopm2Almchannel38PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel38Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.90.1.1 | Columnpmopm2Almchannel38PortIndex | read-only | current | Index definition for the pmopm2Almchannel38Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.90.1.2 | Columnpmopm2AlmChannel38AbsentPortn | read-only | current | Channel Absent 38 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.90.1.3 | Columnpmopm2AlmChannel38MismatchPortn | read-only | current | Channel Mismatch 38 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.90.1.4 | Columnpmopm2AlmChannel38BalancedPortn | read-only | current | Channel Balanced 38 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.90.1.5 | Columnpmopm2AlmChannel38PowerLowPortn | read-only | current | Channel Power Low 38 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.90.1.6 | Columnpmopm2AlmChannel38PowerHighPortn | read-only | current | Channel Power High 38 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.90.1.7 | Columnpmopm2AlmChannel38OosPortn | read-only | current | Channel Out Of Service 38 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL3… |
| 1.3.6.1.4.1.20044.64.2.2.3.92 | Tablepmopm2Almchannel39PortTable | not-accessible | current | List of pmopm2Almchannel39Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.92.1 | Rowpmopm2Almchannel39PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel39Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.92.1.1 | Columnpmopm2Almchannel39PortIndex | read-only | current | Index definition for the pmopm2Almchannel39Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.92.1.2 | Columnpmopm2AlmChannel39AbsentPortn | read-only | current | Channel Absent 39 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.92.1.3 | Columnpmopm2AlmChannel39MismatchPortn | read-only | current | Channel Mismatch 39 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.92.1.4 | Columnpmopm2AlmChannel39BalancedPortn | read-only | current | Channel Balanced 39 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.92.1.5 | Columnpmopm2AlmChannel39PowerLowPortn | read-only | current | Channel Power Low 39 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.92.1.6 | Columnpmopm2AlmChannel39PowerHighPortn | read-only | current | Channel Power High 39 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.92.1.7 | Columnpmopm2AlmChannel39OosPortn | read-only | current | Channel Out Of Service 39 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL3… |
| 1.3.6.1.4.1.20044.64.2.2.3.94 | Tablepmopm2Almchannel40PortTable | not-accessible | current | List of pmopm2Almchannel40Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.94.1 | Rowpmopm2Almchannel40PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel40Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.94.1.1 | Columnpmopm2Almchannel40PortIndex | read-only | current | Index definition for the pmopm2Almchannel40Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.94.1.2 | Columnpmopm2AlmChannel40AbsentPortn | read-only | current | Channel Absent 40 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.94.1.3 | Columnpmopm2AlmChannel40MismatchPortn | read-only | current | Channel Mismatch 40 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.94.1.4 | Columnpmopm2AlmChannel40BalancedPortn | read-only | current | Channel Balanced 40 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.94.1.5 | Columnpmopm2AlmChannel40PowerLowPortn | read-only | current | Channel Power Low 40 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.94.1.6 | Columnpmopm2AlmChannel40PowerHighPortn | read-only | current | Channel Power High 40 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.94.1.7 | Columnpmopm2AlmChannel40OosPortn | read-only | current | Channel Out Of Service 40 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL4… |
| 1.3.6.1.4.1.20044.64.2.2.3.96 | Tablepmopm2Almchannel41PortTable | not-accessible | current | List of pmopm2Almchannel41Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.96.1 | Rowpmopm2Almchannel41PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel41Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.96.1.1 | Columnpmopm2Almchannel41PortIndex | read-only | current | Index definition for the pmopm2Almchannel41Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.96.1.2 | Columnpmopm2AlmChannel41AbsentPortn | read-only | current | Channel Absent 41 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.96.1.3 | Columnpmopm2AlmChannel41MismatchPortn | read-only | current | Channel Mismatch 41 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.96.1.4 | Columnpmopm2AlmChannel41BalancedPortn | read-only | current | Channel Balanced 41 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.96.1.5 | Columnpmopm2AlmChannel41PowerLowPortn | read-only | current | Channel Power Low 41 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.96.1.6 | Columnpmopm2AlmChannel41PowerHighPortn | read-only | current | Channel Power High 41 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.96.1.7 | Columnpmopm2AlmChannel41OosPortn | read-only | current | Channel Out Of Service 41 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL4… |
| 1.3.6.1.4.1.20044.64.2.2.3.98 | Tablepmopm2Almchannel42PortTable | not-accessible | current | List of pmopm2Almchannel42Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.98.1 | Rowpmopm2Almchannel42PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel42Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.98.1.1 | Columnpmopm2Almchannel42PortIndex | read-only | current | Index definition for the pmopm2Almchannel42Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.98.1.2 | Columnpmopm2AlmChannel42AbsentPortn | read-only | current | Channel Absent 42 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.98.1.3 | Columnpmopm2AlmChannel42MismatchPortn | read-only | current | Channel Mismatch 42 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.98.1.4 | Columnpmopm2AlmChannel42BalancedPortn | read-only | current | Channel Balanced 42 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.98.1.5 | Columnpmopm2AlmChannel42PowerLowPortn | read-only | current | Channel Power Low 42 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.98.1.6 | Columnpmopm2AlmChannel42PowerHighPortn | read-only | current | Channel Power High 42 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.98.1.7 | Columnpmopm2AlmChannel42OosPortn | read-only | current | Channel Out Of Service 42 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL4… |
| 1.3.6.1.4.1.20044.64.2.2.3.100 | Tablepmopm2Almchannel43PortTable | not-accessible | current | List of pmopm2Almchannel43Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.100.1 | Rowpmopm2Almchannel43PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel43Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.100.1.1 | Columnpmopm2Almchannel43PortIndex | read-only | current | Index definition for the pmopm2Almchannel43Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.100.1.2 | Columnpmopm2AlmChannel43AbsentPortn | read-only | current | Channel Absent 43 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.100.1.3 | Columnpmopm2AlmChannel43MismatchPortn | read-only | current | Channel Mismatch 43 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.100.1.4 | Columnpmopm2AlmChannel43BalancedPortn | read-only | current | Channel Balanced 43 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.100.1.5 | Columnpmopm2AlmChannel43PowerLowPortn | read-only | current | Channel Power Low 43 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.100.1.6 | Columnpmopm2AlmChannel43PowerHighPortn | read-only | current | Channel Power High 43 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.100.1.7 | Columnpmopm2AlmChannel43OosPortn | read-only | current | Channel Out Of Service 43 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL4… |
| 1.3.6.1.4.1.20044.64.2.2.3.102 | Tablepmopm2Almchannel44PortTable | not-accessible | current | List of pmopm2Almchannel44Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.102.1 | Rowpmopm2Almchannel44PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel44Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.102.1.1 | Columnpmopm2Almchannel44PortIndex | read-only | current | Index definition for the pmopm2Almchannel44Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.102.1.2 | Columnpmopm2AlmChannel44AbsentPortn | read-only | current | Channel Absent 44 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.102.1.3 | Columnpmopm2AlmChannel44MismatchPortn | read-only | current | Channel Mismatch 44 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.102.1.4 | Columnpmopm2AlmChannel44BalancedPortn | read-only | current | Channel Balanced 44 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.102.1.5 | Columnpmopm2AlmChannel44PowerLowPortn | read-only | current | Channel Power Low 44 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.102.1.6 | Columnpmopm2AlmChannel44PowerHighPortn | read-only | current | Channel Power High 44 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.102.1.7 | Columnpmopm2AlmChannel44OosPortn | read-only | current | Channel Out Of Service 44 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL4… |
| 1.3.6.1.4.1.20044.64.2.2.3.104 | Tablepmopm2Almchannel45PortTable | not-accessible | current | List of pmopm2Almchannel45Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.104.1 | Rowpmopm2Almchannel45PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel45Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.104.1.1 | Columnpmopm2Almchannel45PortIndex | read-only | current | Index definition for the pmopm2Almchannel45Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.104.1.2 | Columnpmopm2AlmChannel45AbsentPortn | read-only | current | Channel Absent 45 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.104.1.3 | Columnpmopm2AlmChannel45MismatchPortn | read-only | current | Channel Mismatch 45 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.104.1.4 | Columnpmopm2AlmChannel45BalancedPortn | read-only | current | Channel Balanced 45 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.104.1.5 | Columnpmopm2AlmChannel45PowerLowPortn | read-only | current | Channel Power Low 45 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.104.1.6 | Columnpmopm2AlmChannel45PowerHighPortn | read-only | current | Channel Power High 45 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.104.1.7 | Columnpmopm2AlmChannel45OosPortn | read-only | current | Channel Out Of Service 45 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL4… |
| 1.3.6.1.4.1.20044.64.2.2.3.106 | Tablepmopm2Almchannel46PortTable | not-accessible | current | List of pmopm2Almchannel46Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.106.1 | Rowpmopm2Almchannel46PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel46Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.106.1.1 | Columnpmopm2Almchannel46PortIndex | read-only | current | Index definition for the pmopm2Almchannel46Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.106.1.2 | Columnpmopm2AlmChannel46AbsentPortn | read-only | current | Channel Absent 46 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.106.1.3 | Columnpmopm2AlmChannel46MismatchPortn | read-only | current | Channel Mismatch 46 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.106.1.4 | Columnpmopm2AlmChannel46BalancedPortn | read-only | current | Channel Balanced 46 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.106.1.5 | Columnpmopm2AlmChannel46PowerLowPortn | read-only | current | Channel Power Low 46 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.106.1.6 | Columnpmopm2AlmChannel46PowerHighPortn | read-only | current | Channel Power High 46 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.106.1.7 | Columnpmopm2AlmChannel46OosPortn | read-only | current | Channel Out Of Service 46 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL4… |
| 1.3.6.1.4.1.20044.64.2.2.3.108 | Tablepmopm2Almchannel47PortTable | not-accessible | current | List of pmopm2Almchannel47Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.108.1 | Rowpmopm2Almchannel47PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel47Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.108.1.1 | Columnpmopm2Almchannel47PortIndex | read-only | current | Index definition for the pmopm2Almchannel47Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.108.1.2 | Columnpmopm2AlmChannel47AbsentPortn | read-only | current | Channel Absent 47 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.108.1.3 | Columnpmopm2AlmChannel47MismatchPortn | read-only | current | Channel Mismatch 47 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.108.1.4 | Columnpmopm2AlmChannel47BalancedPortn | read-only | current | Channel Balanced 47 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.108.1.5 | Columnpmopm2AlmChannel47PowerLowPortn | read-only | current | Channel Power Low 47 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.108.1.6 | Columnpmopm2AlmChannel47PowerHighPortn | read-only | current | Channel Power High 47 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.108.1.7 | Columnpmopm2AlmChannel47OosPortn | read-only | current | Channel Out Of Service 47 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL4… |
| 1.3.6.1.4.1.20044.64.2.2.3.110 | Tablepmopm2Almchannel48PortTable | not-accessible | current | List of pmopm2Almchannel48Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.110.1 | Rowpmopm2Almchannel48PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel48Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.110.1.1 | Columnpmopm2Almchannel48PortIndex | read-only | current | Index definition for the pmopm2Almchannel48Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.110.1.2 | Columnpmopm2AlmChannel48AbsentPortn | read-only | current | Channel Absent 48 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.110.1.3 | Columnpmopm2AlmChannel48MismatchPortn | read-only | current | Channel Mismatch 48 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.110.1.4 | Columnpmopm2AlmChannel48BalancedPortn | read-only | current | Channel Balanced 48 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.110.1.5 | Columnpmopm2AlmChannel48PowerLowPortn | read-only | current | Channel Power Low 48 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.110.1.6 | Columnpmopm2AlmChannel48PowerHighPortn | read-only | current | Channel Power High 48 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.110.1.7 | Columnpmopm2AlmChannel48OosPortn | read-only | current | Channel Out Of Service 48 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL4… |
| 1.3.6.1.4.1.20044.64.2.2.3.112 | Tablepmopm2Almchannel49PortTable | not-accessible | current | List of pmopm2Almchannel49Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.112.1 | Rowpmopm2Almchannel49PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel49Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.112.1.1 | Columnpmopm2Almchannel49PortIndex | read-only | current | Index definition for the pmopm2Almchannel49Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.112.1.2 | Columnpmopm2AlmChannel49AbsentPortn | read-only | current | Channel Absent 49 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.112.1.3 | Columnpmopm2AlmChannel49MismatchPortn | read-only | current | Channel Mismatch 49 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.112.1.4 | Columnpmopm2AlmChannel49BalancedPortn | read-only | current | Channel Balanced 49 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.112.1.5 | Columnpmopm2AlmChannel49PowerLowPortn | read-only | current | Channel Power Low 49 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.112.1.6 | Columnpmopm2AlmChannel49PowerHighPortn | read-only | current | Channel Power High 49 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.112.1.7 | Columnpmopm2AlmChannel49OosPortn | read-only | current | Channel Out Of Service 49 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL4… |
| 1.3.6.1.4.1.20044.64.2.2.3.114 | Tablepmopm2Almchannel50PortTable | not-accessible | current | List of pmopm2Almchannel50Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.114.1 | Rowpmopm2Almchannel50PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel50Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.114.1.1 | Columnpmopm2Almchannel50PortIndex | read-only | current | Index definition for the pmopm2Almchannel50Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.114.1.2 | Columnpmopm2AlmChannel50AbsentPortn | read-only | current | Channel Absent 50 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.114.1.3 | Columnpmopm2AlmChannel50MismatchPortn | read-only | current | Channel Mismatch 50 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.114.1.4 | Columnpmopm2AlmChannel50BalancedPortn | read-only | current | Channel Balanced 50 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.114.1.5 | Columnpmopm2AlmChannel50PowerLowPortn | read-only | current | Channel Power Low 50 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.114.1.6 | Columnpmopm2AlmChannel50PowerHighPortn | read-only | current | Channel Power High 50 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.114.1.7 | Columnpmopm2AlmChannel50OosPortn | read-only | current | Channel Out Of Service 50 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL5… |
| 1.3.6.1.4.1.20044.64.2.2.3.116 | Tablepmopm2Almchannel51PortTable | not-accessible | current | List of pmopm2Almchannel51Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.116.1 | Rowpmopm2Almchannel51PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel51Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.116.1.1 | Columnpmopm2Almchannel51PortIndex | read-only | current | Index definition for the pmopm2Almchannel51Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.116.1.2 | Columnpmopm2AlmChannel51AbsentPortn | read-only | current | Channel Absent 51 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.116.1.3 | Columnpmopm2AlmChannel51MismatchPortn | read-only | current | Channel Mismatch 51 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.116.1.4 | Columnpmopm2AlmChannel51BalancedPortn | read-only | current | Channel Balanced 51 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.116.1.5 | Columnpmopm2AlmChannel51PowerLowPortn | read-only | current | Channel Power Low 51 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.116.1.6 | Columnpmopm2AlmChannel51PowerHighPortn | read-only | current | Channel Power High 51 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.116.1.7 | Columnpmopm2AlmChannel51OosPortn | read-only | current | Channel Out Of Service 51 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL5… |
| 1.3.6.1.4.1.20044.64.2.2.3.118 | Tablepmopm2Almchannel52PortTable | not-accessible | current | List of pmopm2Almchannel52Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.118.1 | Rowpmopm2Almchannel52PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel52Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.118.1.1 | Columnpmopm2Almchannel52PortIndex | read-only | current | Index definition for the pmopm2Almchannel52Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.118.1.2 | Columnpmopm2AlmChannel52AbsentPortn | read-only | current | Channel Absent 52 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.118.1.3 | Columnpmopm2AlmChannel52MismatchPortn | read-only | current | Channel Mismatch 52 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.118.1.4 | Columnpmopm2AlmChannel52BalancedPortn | read-only | current | Channel Balanced 52 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.118.1.5 | Columnpmopm2AlmChannel52PowerLowPortn | read-only | current | Channel Power Low 52 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.118.1.6 | Columnpmopm2AlmChannel52PowerHighPortn | read-only | current | Channel Power High 52 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.118.1.7 | Columnpmopm2AlmChannel52OosPortn | read-only | current | Channel Out Of Service 52 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL5… |
| 1.3.6.1.4.1.20044.64.2.2.3.120 | Tablepmopm2Almchannel53PortTable | not-accessible | current | List of pmopm2Almchannel53Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.120.1 | Rowpmopm2Almchannel53PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel53Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.120.1.1 | Columnpmopm2Almchannel53PortIndex | read-only | current | Index definition for the pmopm2Almchannel53Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.120.1.2 | Columnpmopm2AlmChannel53AbsentPortn | read-only | current | Channel Absent 53 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.120.1.3 | Columnpmopm2AlmChannel53MismatchPortn | read-only | current | Channel Mismatch 53 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.120.1.4 | Columnpmopm2AlmChannel53BalancedPortn | read-only | current | Channel Balanced 53 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.120.1.5 | Columnpmopm2AlmChannel53PowerLowPortn | read-only | current | Channel Power Low 53 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.120.1.6 | Columnpmopm2AlmChannel53PowerHighPortn | read-only | current | Channel Power High 53 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.120.1.7 | Columnpmopm2AlmChannel53OosPortn | read-only | current | Channel Out Of Service 53 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL5… |
| 1.3.6.1.4.1.20044.64.2.2.3.122 | Tablepmopm2Almchannel54PortTable | not-accessible | current | List of pmopm2Almchannel54Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.122.1 | Rowpmopm2Almchannel54PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel54Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.122.1.1 | Columnpmopm2Almchannel54PortIndex | read-only | current | Index definition for the pmopm2Almchannel54Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.122.1.2 | Columnpmopm2AlmChannel54AbsentPortn | read-only | current | Channel Absent 54 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.122.1.3 | Columnpmopm2AlmChannel54MismatchPortn | read-only | current | Channel Mismatch 54 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.122.1.4 | Columnpmopm2AlmChannel54BalancedPortn | read-only | current | Channel Balanced 54 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.122.1.5 | Columnpmopm2AlmChannel54PowerLowPortn | read-only | current | Channel Power Low 54 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.122.1.6 | Columnpmopm2AlmChannel54PowerHighPortn | read-only | current | Channel Power High 54 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.122.1.7 | Columnpmopm2AlmChannel54OosPortn | read-only | current | Channel Out Of Service 54 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL5… |
| 1.3.6.1.4.1.20044.64.2.2.3.124 | Tablepmopm2Almchannel55PortTable | not-accessible | current | List of pmopm2Almchannel55Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.124.1 | Rowpmopm2Almchannel55PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel55Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.124.1.1 | Columnpmopm2Almchannel55PortIndex | read-only | current | Index definition for the pmopm2Almchannel55Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.124.1.2 | Columnpmopm2AlmChannel55AbsentPortn | read-only | current | Channel Absent 55 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.124.1.3 | Columnpmopm2AlmChannel55MismatchPortn | read-only | current | Channel Mismatch 55 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.124.1.4 | Columnpmopm2AlmChannel55BalancedPortn | read-only | current | Channel Balanced 55 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.124.1.5 | Columnpmopm2AlmChannel55PowerLowPortn | read-only | current | Channel Power Low 55 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.124.1.6 | Columnpmopm2AlmChannel55PowerHighPortn | read-only | current | Channel Power High 55 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.124.1.7 | Columnpmopm2AlmChannel55OosPortn | read-only | current | Channel Out Of Service 55 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL5… |
| 1.3.6.1.4.1.20044.64.2.2.3.126 | Tablepmopm2Almchannel56PortTable | not-accessible | current | List of pmopm2Almchannel56Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.126.1 | Rowpmopm2Almchannel56PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel56Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.126.1.1 | Columnpmopm2Almchannel56PortIndex | read-only | current | Index definition for the pmopm2Almchannel56Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.126.1.2 | Columnpmopm2AlmChannel56AbsentPortn | read-only | current | Channel Absent 56 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.126.1.3 | Columnpmopm2AlmChannel56MismatchPortn | read-only | current | Channel Mismatch 56 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.126.1.4 | Columnpmopm2AlmChannel56BalancedPortn | read-only | current | Channel Balanced 56 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.126.1.5 | Columnpmopm2AlmChannel56PowerLowPortn | read-only | current | Channel Power Low 56 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.126.1.6 | Columnpmopm2AlmChannel56PowerHighPortn | read-only | current | Channel Power High 56 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.126.1.7 | Columnpmopm2AlmChannel56OosPortn | read-only | current | Channel Out Of Service 56 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL5… |
| 1.3.6.1.4.1.20044.64.2.2.3.128 | Tablepmopm2Almchannel57PortTable | not-accessible | current | List of pmopm2Almchannel57Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.128.1 | Rowpmopm2Almchannel57PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel57Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.128.1.1 | Columnpmopm2Almchannel57PortIndex | read-only | current | Index definition for the pmopm2Almchannel57Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.128.1.2 | Columnpmopm2AlmChannel57AbsentPortn | read-only | current | Channel Absent 57 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.128.1.3 | Columnpmopm2AlmChannel57MismatchPortn | read-only | current | Channel Mismatch 57 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.128.1.4 | Columnpmopm2AlmChannel57BalancedPortn | read-only | current | Channel Balanced 57 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.128.1.5 | Columnpmopm2AlmChannel57PowerLowPortn | read-only | current | Channel Power Low 57 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.128.1.6 | Columnpmopm2AlmChannel57PowerHighPortn | read-only | current | Channel Power High 57 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.128.1.7 | Columnpmopm2AlmChannel57OosPortn | read-only | current | Channel Out Of Service 57 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL5… |
| 1.3.6.1.4.1.20044.64.2.2.3.130 | Tablepmopm2Almchannel58PortTable | not-accessible | current | List of pmopm2Almchannel58Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.130.1 | Rowpmopm2Almchannel58PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel58Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.130.1.1 | Columnpmopm2Almchannel58PortIndex | read-only | current | Index definition for the pmopm2Almchannel58Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.130.1.2 | Columnpmopm2AlmChannel58AbsentPortn | read-only | current | Channel Absent 58 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.130.1.3 | Columnpmopm2AlmChannel58MismatchPortn | read-only | current | Channel Mismatch 58 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.130.1.4 | Columnpmopm2AlmChannel58BalancedPortn | read-only | current | Channel Balanced 58 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.130.1.5 | Columnpmopm2AlmChannel58PowerLowPortn | read-only | current | Channel Power Low 58 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.130.1.6 | Columnpmopm2AlmChannel58PowerHighPortn | read-only | current | Channel Power High 58 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.130.1.7 | Columnpmopm2AlmChannel58OosPortn | read-only | current | Channel Out Of Service 58 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL5… |
| 1.3.6.1.4.1.20044.64.2.2.3.132 | Tablepmopm2Almchannel59PortTable | not-accessible | current | List of pmopm2Almchannel59Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.132.1 | Rowpmopm2Almchannel59PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel59Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.132.1.1 | Columnpmopm2Almchannel59PortIndex | read-only | current | Index definition for the pmopm2Almchannel59Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.132.1.2 | Columnpmopm2AlmChannel59AbsentPortn | read-only | current | Channel Absent 59 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.132.1.3 | Columnpmopm2AlmChannel59MismatchPortn | read-only | current | Channel Mismatch 59 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.132.1.4 | Columnpmopm2AlmChannel59BalancedPortn | read-only | current | Channel Balanced 59 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.132.1.5 | Columnpmopm2AlmChannel59PowerLowPortn | read-only | current | Channel Power Low 59 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.132.1.6 | Columnpmopm2AlmChannel59PowerHighPortn | read-only | current | Channel Power High 59 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.132.1.7 | Columnpmopm2AlmChannel59OosPortn | read-only | current | Channel Out Of Service 59 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL5… |
| 1.3.6.1.4.1.20044.64.2.2.3.134 | Tablepmopm2Almchannel60PortTable | not-accessible | current | List of pmopm2Almchannel60Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.134.1 | Rowpmopm2Almchannel60PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel60Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.134.1.1 | Columnpmopm2Almchannel60PortIndex | read-only | current | Index definition for the pmopm2Almchannel60Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.134.1.2 | Columnpmopm2AlmChannel60AbsentPortn | read-only | current | Channel Absent 60 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.134.1.3 | Columnpmopm2AlmChannel60MismatchPortn | read-only | current | Channel Mismatch 60 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.134.1.4 | Columnpmopm2AlmChannel60BalancedPortn | read-only | current | Channel Balanced 60 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.134.1.5 | Columnpmopm2AlmChannel60PowerLowPortn | read-only | current | Channel Power Low 60 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.134.1.6 | Columnpmopm2AlmChannel60PowerHighPortn | read-only | current | Channel Power High 60 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.134.1.7 | Columnpmopm2AlmChannel60OosPortn | read-only | current | Channel Out Of Service 60 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL6… |
| 1.3.6.1.4.1.20044.64.2.2.3.136 | Tablepmopm2Almchannel61PortTable | not-accessible | current | List of pmopm2Almchannel61Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.136.1 | Rowpmopm2Almchannel61PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel61Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.136.1.1 | Columnpmopm2Almchannel61PortIndex | read-only | current | Index definition for the pmopm2Almchannel61Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.136.1.2 | Columnpmopm2AlmChannel61AbsentPortn | read-only | current | Channel Absent 61 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.136.1.3 | Columnpmopm2AlmChannel61MismatchPortn | read-only | current | Channel Mismatch 61 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.136.1.4 | Columnpmopm2AlmChannel61BalancedPortn | read-only | current | Channel Balanced 61 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.136.1.5 | Columnpmopm2AlmChannel61PowerLowPortn | read-only | current | Channel Power Low 61 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.136.1.6 | Columnpmopm2AlmChannel61PowerHighPortn | read-only | current | Channel Power High 61 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.136.1.7 | Columnpmopm2AlmChannel61OosPortn | read-only | current | Channel Out Of Service 61 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL6… |
| 1.3.6.1.4.1.20044.64.2.2.3.138 | Tablepmopm2Almchannel62PortTable | not-accessible | current | List of pmopm2Almchannel62Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.138.1 | Rowpmopm2Almchannel62PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel62Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.138.1.1 | Columnpmopm2Almchannel62PortIndex | read-only | current | Index definition for the pmopm2Almchannel62Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.138.1.2 | Columnpmopm2AlmChannel62AbsentPortn | read-only | current | Channel Absent 62 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.138.1.3 | Columnpmopm2AlmChannel62MismatchPortn | read-only | current | Channel Mismatch 62 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.138.1.4 | Columnpmopm2AlmChannel62BalancedPortn | read-only | current | Channel Balanced 62 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.138.1.5 | Columnpmopm2AlmChannel62PowerLowPortn | read-only | current | Channel Power Low 62 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.138.1.6 | Columnpmopm2AlmChannel62PowerHighPortn | read-only | current | Channel Power High 62 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.138.1.7 | Columnpmopm2AlmChannel62OosPortn | read-only | current | Channel Out Of Service 62 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL6… |
| 1.3.6.1.4.1.20044.64.2.2.3.140 | Tablepmopm2Almchannel63PortTable | not-accessible | current | List of pmopm2Almchannel63Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.140.1 | Rowpmopm2Almchannel63PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel63Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.140.1.1 | Columnpmopm2Almchannel63PortIndex | read-only | current | Index definition for the pmopm2Almchannel63Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.140.1.2 | Columnpmopm2AlmChannel63AbsentPortn | read-only | current | Channel Absent 63 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.140.1.3 | Columnpmopm2AlmChannel63MismatchPortn | read-only | current | Channel Mismatch 63 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.140.1.4 | Columnpmopm2AlmChannel63BalancedPortn | read-only | current | Channel Balanced 63 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.140.1.5 | Columnpmopm2AlmChannel63PowerLowPortn | read-only | current | Channel Power Low 63 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.140.1.6 | Columnpmopm2AlmChannel63PowerHighPortn | read-only | current | Channel Power High 63 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.140.1.7 | Columnpmopm2AlmChannel63OosPortn | read-only | current | Channel Out Of Service 63 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL6… |
| 1.3.6.1.4.1.20044.64.2.2.3.142 | Tablepmopm2Almchannel64PortTable | not-accessible | current | List of pmopm2Almchannel64Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.142.1 | Rowpmopm2Almchannel64PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel64Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.142.1.1 | Columnpmopm2Almchannel64PortIndex | read-only | current | Index definition for the pmopm2Almchannel64Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.142.1.2 | Columnpmopm2AlmChannel64AbsentPortn | read-only | current | Channel Absent 64 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.142.1.3 | Columnpmopm2AlmChannel64MismatchPortn | read-only | current | Channel Mismatch 64 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.142.1.4 | Columnpmopm2AlmChannel64BalancedPortn | read-only | current | Channel Balanced 64 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.142.1.5 | Columnpmopm2AlmChannel64PowerLowPortn | read-only | current | Channel Power Low 64 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.142.1.6 | Columnpmopm2AlmChannel64PowerHighPortn | read-only | current | Channel Power High 64 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.142.1.7 | Columnpmopm2AlmChannel64OosPortn | read-only | current | Channel Out Of Service 64 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL6… |
| 1.3.6.1.4.1.20044.64.2.2.3.144 | Tablepmopm2Almchannel65PortTable | not-accessible | current | List of pmopm2Almchannel65Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.144.1 | Rowpmopm2Almchannel65PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel65Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.144.1.1 | Columnpmopm2Almchannel65PortIndex | read-only | current | Index definition for the pmopm2Almchannel65Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.144.1.2 | Columnpmopm2AlmChannel65AbsentPortn | read-only | current | Channel Absent 65 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.144.1.3 | Columnpmopm2AlmChannel65MismatchPortn | read-only | current | Channel Mismatch 65 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.144.1.4 | Columnpmopm2AlmChannel65BalancedPortn | read-only | current | Channel Balanced 65 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.144.1.5 | Columnpmopm2AlmChannel65PowerLowPortn | read-only | current | Channel Power Low 65 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.144.1.6 | Columnpmopm2AlmChannel65PowerHighPortn | read-only | current | Channel Power High 65 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.144.1.7 | Columnpmopm2AlmChannel65OosPortn | read-only | current | Channel Out Of Service 65 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL6… |
| 1.3.6.1.4.1.20044.64.2.2.3.146 | Tablepmopm2Almchannel66PortTable | not-accessible | current | List of pmopm2Almchannel66Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.146.1 | Rowpmopm2Almchannel66PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel66Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.146.1.1 | Columnpmopm2Almchannel66PortIndex | read-only | current | Index definition for the pmopm2Almchannel66Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.146.1.2 | Columnpmopm2AlmChannel66AbsentPortn | read-only | current | Channel Absent 66 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.146.1.3 | Columnpmopm2AlmChannel66MismatchPortn | read-only | current | Channel Mismatch 66 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.146.1.4 | Columnpmopm2AlmChannel66BalancedPortn | read-only | current | Channel Balanced 66 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.146.1.5 | Columnpmopm2AlmChannel66PowerLowPortn | read-only | current | Channel Power Low 66 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.146.1.6 | Columnpmopm2AlmChannel66PowerHighPortn | read-only | current | Channel Power High 66 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.146.1.7 | Columnpmopm2AlmChannel66OosPortn | read-only | current | Channel Out Of Service 66 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL6… |
| 1.3.6.1.4.1.20044.64.2.2.3.148 | Tablepmopm2Almchannel67PortTable | not-accessible | current | List of pmopm2Almchannel67Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.148.1 | Rowpmopm2Almchannel67PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel67Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.148.1.1 | Columnpmopm2Almchannel67PortIndex | read-only | current | Index definition for the pmopm2Almchannel67Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.148.1.2 | Columnpmopm2AlmChannel67AbsentPortn | read-only | current | Channel Absent 67 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.148.1.3 | Columnpmopm2AlmChannel67MismatchPortn | read-only | current | Channel Mismatch 67 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.148.1.4 | Columnpmopm2AlmChannel67BalancedPortn | read-only | current | Channel Balanced 67 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.148.1.5 | Columnpmopm2AlmChannel67PowerLowPortn | read-only | current | Channel Power Low 67 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.148.1.6 | Columnpmopm2AlmChannel67PowerHighPortn | read-only | current | Channel Power High 67 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.148.1.7 | Columnpmopm2AlmChannel67OosPortn | read-only | current | Channel Out Of Service 67 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL6… |
| 1.3.6.1.4.1.20044.64.2.2.3.150 | Tablepmopm2Almchannel68PortTable | not-accessible | current | List of pmopm2Almchannel68Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.150.1 | Rowpmopm2Almchannel68PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel68Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.150.1.1 | Columnpmopm2Almchannel68PortIndex | read-only | current | Index definition for the pmopm2Almchannel68Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.150.1.2 | Columnpmopm2AlmChannel68AbsentPortn | read-only | current | Channel Absent 68 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.150.1.3 | Columnpmopm2AlmChannel68MismatchPortn | read-only | current | Channel Mismatch 68 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.150.1.4 | Columnpmopm2AlmChannel68BalancedPortn | read-only | current | Channel Balanced 68 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.150.1.5 | Columnpmopm2AlmChannel68PowerLowPortn | read-only | current | Channel Power Low 68 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.150.1.6 | Columnpmopm2AlmChannel68PowerHighPortn | read-only | current | Channel Power High 68 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.150.1.7 | Columnpmopm2AlmChannel68OosPortn | read-only | current | Channel Out Of Service 68 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL6… |
| 1.3.6.1.4.1.20044.64.2.2.3.152 | Tablepmopm2Almchannel69PortTable | not-accessible | current | List of pmopm2Almchannel69Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.152.1 | Rowpmopm2Almchannel69PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel69Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.152.1.1 | Columnpmopm2Almchannel69PortIndex | read-only | current | Index definition for the pmopm2Almchannel69Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.152.1.2 | Columnpmopm2AlmChannel69AbsentPortn | read-only | current | Channel Absent 69 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.152.1.3 | Columnpmopm2AlmChannel69MismatchPortn | read-only | current | Channel Mismatch 69 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.152.1.4 | Columnpmopm2AlmChannel69BalancedPortn | read-only | current | Channel Balanced 69 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.152.1.5 | Columnpmopm2AlmChannel69PowerLowPortn | read-only | current | Channel Power Low 69 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.152.1.6 | Columnpmopm2AlmChannel69PowerHighPortn | read-only | current | Channel Power High 69 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.152.1.7 | Columnpmopm2AlmChannel69OosPortn | read-only | current | Channel Out Of Service 69 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL6… |
| 1.3.6.1.4.1.20044.64.2.2.3.154 | Tablepmopm2Almchannel70PortTable | not-accessible | current | List of pmopm2Almchannel70Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.154.1 | Rowpmopm2Almchannel70PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel70Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.154.1.1 | Columnpmopm2Almchannel70PortIndex | read-only | current | Index definition for the pmopm2Almchannel70Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.154.1.2 | Columnpmopm2AlmChannel70AbsentPortn | read-only | current | Channel Absent 70 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.154.1.3 | Columnpmopm2AlmChannel70MismatchPortn | read-only | current | Channel Mismatch 70 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.154.1.4 | Columnpmopm2AlmChannel70BalancedPortn | read-only | current | Channel Balanced 70 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.154.1.5 | Columnpmopm2AlmChannel70PowerLowPortn | read-only | current | Channel Power Low 70 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.154.1.6 | Columnpmopm2AlmChannel70PowerHighPortn | read-only | current | Channel Power High 70 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.154.1.7 | Columnpmopm2AlmChannel70OosPortn | read-only | current | Channel Out Of Service 70 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL7… |
| 1.3.6.1.4.1.20044.64.2.2.3.156 | Tablepmopm2Almchannel71PortTable | not-accessible | current | List of pmopm2Almchannel71Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.156.1 | Rowpmopm2Almchannel71PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel71Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.156.1.1 | Columnpmopm2Almchannel71PortIndex | read-only | current | Index definition for the pmopm2Almchannel71Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.156.1.2 | Columnpmopm2AlmChannel71AbsentPortn | read-only | current | Channel Absent 71 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.156.1.3 | Columnpmopm2AlmChannel71MismatchPortn | read-only | current | Channel Mismatch 71 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.156.1.4 | Columnpmopm2AlmChannel71BalancedPortn | read-only | current | Channel Balanced 71 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.156.1.5 | Columnpmopm2AlmChannel71PowerLowPortn | read-only | current | Channel Power Low 71 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.156.1.6 | Columnpmopm2AlmChannel71PowerHighPortn | read-only | current | Channel Power High 71 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.156.1.7 | Columnpmopm2AlmChannel71OosPortn | read-only | current | Channel Out Of Service 71 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL7… |
| 1.3.6.1.4.1.20044.64.2.2.3.158 | Tablepmopm2Almchannel72PortTable | not-accessible | current | List of pmopm2Almchannel72Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.158.1 | Rowpmopm2Almchannel72PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel72Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.158.1.1 | Columnpmopm2Almchannel72PortIndex | read-only | current | Index definition for the pmopm2Almchannel72Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.158.1.2 | Columnpmopm2AlmChannel72AbsentPortn | read-only | current | Channel Absent 72 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.158.1.3 | Columnpmopm2AlmChannel72MismatchPortn | read-only | current | Channel Mismatch 72 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.158.1.4 | Columnpmopm2AlmChannel72BalancedPortn | read-only | current | Channel Balanced 72 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.158.1.5 | Columnpmopm2AlmChannel72PowerLowPortn | read-only | current | Channel Power Low 72 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.158.1.6 | Columnpmopm2AlmChannel72PowerHighPortn | read-only | current | Channel Power High 72 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.158.1.7 | Columnpmopm2AlmChannel72OosPortn | read-only | current | Channel Out Of Service 72 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL7… |
| 1.3.6.1.4.1.20044.64.2.2.3.160 | Tablepmopm2Almchannel73PortTable | not-accessible | current | List of pmopm2Almchannel73Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.160.1 | Rowpmopm2Almchannel73PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel73Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.160.1.1 | Columnpmopm2Almchannel73PortIndex | read-only | current | Index definition for the pmopm2Almchannel73Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.160.1.2 | Columnpmopm2AlmChannel73AbsentPortn | read-only | current | Channel Absent 73 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.160.1.3 | Columnpmopm2AlmChannel73MismatchPortn | read-only | current | Channel Mismatch 73 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.160.1.4 | Columnpmopm2AlmChannel73BalancedPortn | read-only | current | Channel Balanced 73 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.160.1.5 | Columnpmopm2AlmChannel73PowerLowPortn | read-only | current | Channel Power Low 73 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.160.1.6 | Columnpmopm2AlmChannel73PowerHighPortn | read-only | current | Channel Power High 73 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.160.1.7 | Columnpmopm2AlmChannel73OosPortn | read-only | current | Channel Out Of Service 73 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL7… |
| 1.3.6.1.4.1.20044.64.2.2.3.162 | Tablepmopm2Almchannel74PortTable | not-accessible | current | List of pmopm2Almchannel74Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.162.1 | Rowpmopm2Almchannel74PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel74Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.162.1.1 | Columnpmopm2Almchannel74PortIndex | read-only | current | Index definition for the pmopm2Almchannel74Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.162.1.2 | Columnpmopm2AlmChannel74AbsentPortn | read-only | current | Channel Absent 74 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.162.1.3 | Columnpmopm2AlmChannel74MismatchPortn | read-only | current | Channel Mismatch 74 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.162.1.4 | Columnpmopm2AlmChannel74BalancedPortn | read-only | current | Channel Balanced 74 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.162.1.5 | Columnpmopm2AlmChannel74PowerLowPortn | read-only | current | Channel Power Low 74 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.162.1.6 | Columnpmopm2AlmChannel74PowerHighPortn | read-only | current | Channel Power High 74 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.162.1.7 | Columnpmopm2AlmChannel74OosPortn | read-only | current | Channel Out Of Service 74 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL7… |
| 1.3.6.1.4.1.20044.64.2.2.3.164 | Tablepmopm2Almchannel75PortTable | not-accessible | current | List of pmopm2Almchannel75Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.164.1 | Rowpmopm2Almchannel75PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel75Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.164.1.1 | Columnpmopm2Almchannel75PortIndex | read-only | current | Index definition for the pmopm2Almchannel75Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.164.1.2 | Columnpmopm2AlmChannel75AbsentPortn | read-only | current | Channel Absent 75 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.164.1.3 | Columnpmopm2AlmChannel75MismatchPortn | read-only | current | Channel Mismatch 75 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.164.1.4 | Columnpmopm2AlmChannel75BalancedPortn | read-only | current | Channel Balanced 75 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.164.1.5 | Columnpmopm2AlmChannel75PowerLowPortn | read-only | current | Channel Power Low 75 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.164.1.6 | Columnpmopm2AlmChannel75PowerHighPortn | read-only | current | Channel Power High 75 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.164.1.7 | Columnpmopm2AlmChannel75OosPortn | read-only | current | Channel Out Of Service 75 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL7… |
| 1.3.6.1.4.1.20044.64.2.2.3.166 | Tablepmopm2Almchannel76PortTable | not-accessible | current | List of pmopm2Almchannel76Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.166.1 | Rowpmopm2Almchannel76PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel76Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.166.1.1 | Columnpmopm2Almchannel76PortIndex | read-only | current | Index definition for the pmopm2Almchannel76Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.166.1.2 | Columnpmopm2AlmChannel76AbsentPortn | read-only | current | Channel Absent 76 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.166.1.3 | Columnpmopm2AlmChannel76MismatchPortn | read-only | current | Channel Mismatch 76 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.166.1.4 | Columnpmopm2AlmChannel76BalancedPortn | read-only | current | Channel Balanced 76 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.166.1.5 | Columnpmopm2AlmChannel76PowerLowPortn | read-only | current | Channel Power Low 76 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.166.1.6 | Columnpmopm2AlmChannel76PowerHighPortn | read-only | current | Channel Power High 76 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.166.1.7 | Columnpmopm2AlmChannel76OosPortn | read-only | current | Channel Out Of Service 76 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL7… |
| 1.3.6.1.4.1.20044.64.2.2.3.168 | Tablepmopm2Almchannel77PortTable | not-accessible | current | List of pmopm2Almchannel77Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.168.1 | Rowpmopm2Almchannel77PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel77Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.168.1.1 | Columnpmopm2Almchannel77PortIndex | read-only | current | Index definition for the pmopm2Almchannel77Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.168.1.2 | Columnpmopm2AlmChannel77AbsentPortn | read-only | current | Channel Absent 77 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.168.1.3 | Columnpmopm2AlmChannel77MismatchPortn | read-only | current | Channel Mismatch 77 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.168.1.4 | Columnpmopm2AlmChannel77BalancedPortn | read-only | current | Channel Balanced 77 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.168.1.5 | Columnpmopm2AlmChannel77PowerLowPortn | read-only | current | Channel Power Low 77 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.168.1.6 | Columnpmopm2AlmChannel77PowerHighPortn | read-only | current | Channel Power High 77 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.168.1.7 | Columnpmopm2AlmChannel77OosPortn | read-only | current | Channel Out Of Service 77 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL7… |
| 1.3.6.1.4.1.20044.64.2.2.3.170 | Tablepmopm2Almchannel78PortTable | not-accessible | current | List of pmopm2Almchannel78Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.170.1 | Rowpmopm2Almchannel78PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel78Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.170.1.1 | Columnpmopm2Almchannel78PortIndex | read-only | current | Index definition for the pmopm2Almchannel78Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.170.1.2 | Columnpmopm2AlmChannel78AbsentPortn | read-only | current | Channel Absent 78 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.170.1.3 | Columnpmopm2AlmChannel78MismatchPortn | read-only | current | Channel Mismatch 78 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.170.1.4 | Columnpmopm2AlmChannel78BalancedPortn | read-only | current | Channel Balanced 78 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.170.1.5 | Columnpmopm2AlmChannel78PowerLowPortn | read-only | current | Channel Power Low 78 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.170.1.6 | Columnpmopm2AlmChannel78PowerHighPortn | read-only | current | Channel Power High 78 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.170.1.7 | Columnpmopm2AlmChannel78OosPortn | read-only | current | Channel Out Of Service 78 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL7… |
| 1.3.6.1.4.1.20044.64.2.2.3.172 | Tablepmopm2Almchannel79PortTable | not-accessible | current | List of pmopm2Almchannel79Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.172.1 | Rowpmopm2Almchannel79PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel79Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.172.1.1 | Columnpmopm2Almchannel79PortIndex | read-only | current | Index definition for the pmopm2Almchannel79Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.172.1.2 | Columnpmopm2AlmChannel79AbsentPortn | read-only | current | Channel Absent 79 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.172.1.3 | Columnpmopm2AlmChannel79MismatchPortn | read-only | current | Channel Mismatch 79 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.172.1.4 | Columnpmopm2AlmChannel79BalancedPortn | read-only | current | Channel Balanced 79 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.172.1.5 | Columnpmopm2AlmChannel79PowerLowPortn | read-only | current | Channel Power Low 79 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.172.1.6 | Columnpmopm2AlmChannel79PowerHighPortn | read-only | current | Channel Power High 79 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.172.1.7 | Columnpmopm2AlmChannel79OosPortn | read-only | current | Channel Out Of Service 79 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL7… |
| 1.3.6.1.4.1.20044.64.2.2.3.174 | Tablepmopm2Almchannel80PortTable | not-accessible | current | List of pmopm2Almchannel80Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.174.1 | Rowpmopm2Almchannel80PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel80Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.174.1.1 | Columnpmopm2Almchannel80PortIndex | read-only | current | Index definition for the pmopm2Almchannel80Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.174.1.2 | Columnpmopm2AlmChannel80AbsentPortn | read-only | current | Channel Absent 80 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.174.1.3 | Columnpmopm2AlmChannel80MismatchPortn | read-only | current | Channel Mismatch 80 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.174.1.4 | Columnpmopm2AlmChannel80BalancedPortn | read-only | current | Channel Balanced 80 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.174.1.5 | Columnpmopm2AlmChannel80PowerLowPortn | read-only | current | Channel Power Low 80 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.174.1.6 | Columnpmopm2AlmChannel80PowerHighPortn | read-only | current | Channel Power High 80 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.174.1.7 | Columnpmopm2AlmChannel80OosPortn | read-only | current | Channel Out Of Service 80 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL8… |
| 1.3.6.1.4.1.20044.64.2.2.3.176 | Tablepmopm2Almchannel81PortTable | not-accessible | current | List of pmopm2Almchannel81Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.176.1 | Rowpmopm2Almchannel81PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel81Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.176.1.1 | Columnpmopm2Almchannel81PortIndex | read-only | current | Index definition for the pmopm2Almchannel81Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.176.1.2 | Columnpmopm2AlmChannel81AbsentPortn | read-only | current | Channel Absent 81 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.176.1.3 | Columnpmopm2AlmChannel81MismatchPortn | read-only | current | Channel Mismatch 81 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.176.1.4 | Columnpmopm2AlmChannel81BalancedPortn | read-only | current | Channel Balanced 81 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.176.1.5 | Columnpmopm2AlmChannel81PowerLowPortn | read-only | current | Channel Power Low 81 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.176.1.6 | Columnpmopm2AlmChannel81PowerHighPortn | read-only | current | Channel Power High 81 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.176.1.7 | Columnpmopm2AlmChannel81OosPortn | read-only | current | Channel Out Of Service 81 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL8… |
| 1.3.6.1.4.1.20044.64.2.2.3.178 | Tablepmopm2Almchannel82PortTable | not-accessible | current | List of pmopm2Almchannel82Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.178.1 | Rowpmopm2Almchannel82PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel82Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.178.1.1 | Columnpmopm2Almchannel82PortIndex | read-only | current | Index definition for the pmopm2Almchannel82Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.178.1.2 | Columnpmopm2AlmChannel82AbsentPortn | read-only | current | Channel Absent 82 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.178.1.3 | Columnpmopm2AlmChannel82MismatchPortn | read-only | current | Channel Mismatch 82 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.178.1.4 | Columnpmopm2AlmChannel82BalancedPortn | read-only | current | Channel Balanced 82 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.178.1.5 | Columnpmopm2AlmChannel82PowerLowPortn | read-only | current | Channel Power Low 82 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.178.1.6 | Columnpmopm2AlmChannel82PowerHighPortn | read-only | current | Channel Power High 82 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.178.1.7 | Columnpmopm2AlmChannel82OosPortn | read-only | current | Channel Out Of Service 82 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL8… |
| 1.3.6.1.4.1.20044.64.2.2.3.180 | Tablepmopm2Almchannel83PortTable | not-accessible | current | List of pmopm2Almchannel83Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.180.1 | Rowpmopm2Almchannel83PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel83Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.180.1.1 | Columnpmopm2Almchannel83PortIndex | read-only | current | Index definition for the pmopm2Almchannel83Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.180.1.2 | Columnpmopm2AlmChannel83AbsentPortn | read-only | current | Channel Absent 83 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.180.1.3 | Columnpmopm2AlmChannel83MismatchPortn | read-only | current | Channel Mismatch 83 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.180.1.4 | Columnpmopm2AlmChannel83BalancedPortn | read-only | current | Channel Balanced 83 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.180.1.5 | Columnpmopm2AlmChannel83PowerLowPortn | read-only | current | Channel Power Low 83 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.180.1.6 | Columnpmopm2AlmChannel83PowerHighPortn | read-only | current | Channel Power High 83 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.180.1.7 | Columnpmopm2AlmChannel83OosPortn | read-only | current | Channel Out Of Service 83 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL8… |
| 1.3.6.1.4.1.20044.64.2.2.3.182 | Tablepmopm2Almchannel84PortTable | not-accessible | current | List of pmopm2Almchannel84Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.182.1 | Rowpmopm2Almchannel84PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel84Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.182.1.1 | Columnpmopm2Almchannel84PortIndex | read-only | current | Index definition for the pmopm2Almchannel84Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.182.1.2 | Columnpmopm2AlmChannel84AbsentPortn | read-only | current | Channel Absent 84 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.182.1.3 | Columnpmopm2AlmChannel84MismatchPortn | read-only | current | Channel Mismatch 84 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.182.1.4 | Columnpmopm2AlmChannel84BalancedPortn | read-only | current | Channel Balanced 84 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.182.1.5 | Columnpmopm2AlmChannel84PowerLowPortn | read-only | current | Channel Power Low 84 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.182.1.6 | Columnpmopm2AlmChannel84PowerHighPortn | read-only | current | Channel Power High 84 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.182.1.7 | Columnpmopm2AlmChannel84OosPortn | read-only | current | Channel Out Of Service 84 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL8… |
| 1.3.6.1.4.1.20044.64.2.2.3.184 | Tablepmopm2Almchannel85PortTable | not-accessible | current | List of pmopm2Almchannel85Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.184.1 | Rowpmopm2Almchannel85PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel85Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.184.1.1 | Columnpmopm2Almchannel85PortIndex | read-only | current | Index definition for the pmopm2Almchannel85Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.184.1.2 | Columnpmopm2AlmChannel85AbsentPortn | read-only | current | Channel Absent 85 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.184.1.3 | Columnpmopm2AlmChannel85MismatchPortn | read-only | current | Channel Mismatch 85 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.184.1.4 | Columnpmopm2AlmChannel85BalancedPortn | read-only | current | Channel Balanced 85 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.184.1.5 | Columnpmopm2AlmChannel85PowerLowPortn | read-only | current | Channel Power Low 85 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.184.1.6 | Columnpmopm2AlmChannel85PowerHighPortn | read-only | current | Channel Power High 85 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.184.1.7 | Columnpmopm2AlmChannel85OosPortn | read-only | current | Channel Out Of Service 85 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL8… |
| 1.3.6.1.4.1.20044.64.2.2.3.186 | Tablepmopm2Almchannel86PortTable | not-accessible | current | List of pmopm2Almchannel86Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.186.1 | Rowpmopm2Almchannel86PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel86Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.186.1.1 | Columnpmopm2Almchannel86PortIndex | read-only | current | Index definition for the pmopm2Almchannel86Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.186.1.2 | Columnpmopm2AlmChannel86AbsentPortn | read-only | current | Channel Absent 86 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.186.1.3 | Columnpmopm2AlmChannel86MismatchPortn | read-only | current | Channel Mismatch 86 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.186.1.4 | Columnpmopm2AlmChannel86BalancedPortn | read-only | current | Channel Balanced 86 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.186.1.5 | Columnpmopm2AlmChannel86PowerLowPortn | read-only | current | Channel Power Low 86 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.186.1.6 | Columnpmopm2AlmChannel86PowerHighPortn | read-only | current | Channel Power High 86 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.186.1.7 | Columnpmopm2AlmChannel86OosPortn | read-only | current | Channel Out Of Service 86 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL8… |
| 1.3.6.1.4.1.20044.64.2.2.3.188 | Tablepmopm2Almchannel87PortTable | not-accessible | current | List of pmopm2Almchannel87Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.188.1 | Rowpmopm2Almchannel87PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel87Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.188.1.1 | Columnpmopm2Almchannel87PortIndex | read-only | current | Index definition for the pmopm2Almchannel87Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.188.1.2 | Columnpmopm2AlmChannel87AbsentPortn | read-only | current | Channel Absent 87 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.188.1.3 | Columnpmopm2AlmChannel87MismatchPortn | read-only | current | Channel Mismatch 87 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.188.1.4 | Columnpmopm2AlmChannel87BalancedPortn | read-only | current | Channel Balanced 87 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.188.1.5 | Columnpmopm2AlmChannel87PowerLowPortn | read-only | current | Channel Power Low 87 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.188.1.6 | Columnpmopm2AlmChannel87PowerHighPortn | read-only | current | Channel Power High 87 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.188.1.7 | Columnpmopm2AlmChannel87OosPortn | read-only | current | Channel Out Of Service 87 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL8… |
| 1.3.6.1.4.1.20044.64.2.2.3.190 | Tablepmopm2Almchannel88PortTable | not-accessible | current | List of pmopm2Almchannel88Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.190.1 | Rowpmopm2Almchannel88PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel88Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.190.1.1 | Columnpmopm2Almchannel88PortIndex | read-only | current | Index definition for the pmopm2Almchannel88Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.190.1.2 | Columnpmopm2AlmChannel88AbsentPortn | read-only | current | Channel Absent 88 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.190.1.3 | Columnpmopm2AlmChannel88MismatchPortn | read-only | current | Channel Mismatch 88 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.190.1.4 | Columnpmopm2AlmChannel88BalancedPortn | read-only | current | Channel Balanced 88 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.190.1.5 | Columnpmopm2AlmChannel88PowerLowPortn | read-only | current | Channel Power Low 88 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.190.1.6 | Columnpmopm2AlmChannel88PowerHighPortn | read-only | current | Channel Power High 88 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.190.1.7 | Columnpmopm2AlmChannel88OosPortn | read-only | current | Channel Out Of Service 88 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL8… |
| 1.3.6.1.4.1.20044.64.2.2.3.192 | Tablepmopm2Almchannel89PortTable | not-accessible | current | List of pmopm2Almchannel89Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.192.1 | Rowpmopm2Almchannel89PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel89Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.192.1.1 | Columnpmopm2Almchannel89PortIndex | read-only | current | Index definition for the pmopm2Almchannel89Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.192.1.2 | Columnpmopm2AlmChannel89AbsentPortn | read-only | current | Channel Absent 89 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.192.1.3 | Columnpmopm2AlmChannel89MismatchPortn | read-only | current | Channel Mismatch 89 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.192.1.4 | Columnpmopm2AlmChannel89BalancedPortn | read-only | current | Channel Balanced 89 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.192.1.5 | Columnpmopm2AlmChannel89PowerLowPortn | read-only | current | Channel Power Low 89 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.192.1.6 | Columnpmopm2AlmChannel89PowerHighPortn | read-only | current | Channel Power High 89 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.192.1.7 | Columnpmopm2AlmChannel89OosPortn | read-only | current | Channel Out Of Service 89 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL8… |
| 1.3.6.1.4.1.20044.64.2.2.3.194 | Tablepmopm2Almchannel90PortTable | not-accessible | current | List of pmopm2Almchannel90Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.194.1 | Rowpmopm2Almchannel90PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel90Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.194.1.1 | Columnpmopm2Almchannel90PortIndex | read-only | current | Index definition for the pmopm2Almchannel90Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.194.1.2 | Columnpmopm2AlmChannel90AbsentPortn | read-only | current | Channel Absent 90 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.194.1.3 | Columnpmopm2AlmChannel90MismatchPortn | read-only | current | Channel Mismatch 90 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.194.1.4 | Columnpmopm2AlmChannel90BalancedPortn | read-only | current | Channel Balanced 90 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.194.1.5 | Columnpmopm2AlmChannel90PowerLowPortn | read-only | current | Channel Power Low 90 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.194.1.6 | Columnpmopm2AlmChannel90PowerHighPortn | read-only | current | Channel Power High 90 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.194.1.7 | Columnpmopm2AlmChannel90OosPortn | read-only | current | Channel Out Of Service 90 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL9… |
| 1.3.6.1.4.1.20044.64.2.2.3.196 | Tablepmopm2Almchannel91PortTable | not-accessible | current | List of pmopm2Almchannel91Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.196.1 | Rowpmopm2Almchannel91PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel91Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.196.1.1 | Columnpmopm2Almchannel91PortIndex | read-only | current | Index definition for the pmopm2Almchannel91Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.196.1.2 | Columnpmopm2AlmChannel91AbsentPortn | read-only | current | Channel Absent 91 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.196.1.3 | Columnpmopm2AlmChannel91MismatchPortn | read-only | current | Channel Mismatch 91 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.196.1.4 | Columnpmopm2AlmChannel91BalancedPortn | read-only | current | Channel Balanced 91 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.196.1.5 | Columnpmopm2AlmChannel91PowerLowPortn | read-only | current | Channel Power Low 91 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.196.1.6 | Columnpmopm2AlmChannel91PowerHighPortn | read-only | current | Channel Power High 91 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.196.1.7 | Columnpmopm2AlmChannel91OosPortn | read-only | current | Channel Out Of Service 91 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL9… |
| 1.3.6.1.4.1.20044.64.2.2.3.198 | Tablepmopm2Almchannel92PortTable | not-accessible | current | List of pmopm2Almchannel92Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.198.1 | Rowpmopm2Almchannel92PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel92Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.198.1.1 | Columnpmopm2Almchannel92PortIndex | read-only | current | Index definition for the pmopm2Almchannel92Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.198.1.2 | Columnpmopm2AlmChannel92AbsentPortn | read-only | current | Channel Absent 92 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.198.1.3 | Columnpmopm2AlmChannel92MismatchPortn | read-only | current | Channel Mismatch 92 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.198.1.4 | Columnpmopm2AlmChannel92BalancedPortn | read-only | current | Channel Balanced 92 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.198.1.5 | Columnpmopm2AlmChannel92PowerLowPortn | read-only | current | Channel Power Low 92 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.198.1.6 | Columnpmopm2AlmChannel92PowerHighPortn | read-only | current | Channel Power High 92 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.198.1.7 | Columnpmopm2AlmChannel92OosPortn | read-only | current | Channel Out Of Service 92 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL9… |
| 1.3.6.1.4.1.20044.64.2.2.3.200 | Tablepmopm2Almchannel93PortTable | not-accessible | current | List of pmopm2Almchannel93Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.200.1 | Rowpmopm2Almchannel93PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel93Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.200.1.1 | Columnpmopm2Almchannel93PortIndex | read-only | current | Index definition for the pmopm2Almchannel93Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.200.1.2 | Columnpmopm2AlmChannel93AbsentPortn | read-only | current | Channel Absent 93 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.200.1.3 | Columnpmopm2AlmChannel93MismatchPortn | read-only | current | Channel Mismatch 93 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.200.1.4 | Columnpmopm2AlmChannel93BalancedPortn | read-only | current | Channel Balanced 93 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.200.1.5 | Columnpmopm2AlmChannel93PowerLowPortn | read-only | current | Channel Power Low 93 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.200.1.6 | Columnpmopm2AlmChannel93PowerHighPortn | read-only | current | Channel Power High 93 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.200.1.7 | Columnpmopm2AlmChannel93OosPortn | read-only | current | Channel Out Of Service 93 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL9… |
| 1.3.6.1.4.1.20044.64.2.2.3.202 | Tablepmopm2Almchannel94PortTable | not-accessible | current | List of pmopm2Almchannel94Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.202.1 | Rowpmopm2Almchannel94PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel94Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.202.1.1 | Columnpmopm2Almchannel94PortIndex | read-only | current | Index definition for the pmopm2Almchannel94Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.202.1.2 | Columnpmopm2AlmChannel94AbsentPortn | read-only | current | Channel Absent 94 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.202.1.3 | Columnpmopm2AlmChannel94MismatchPortn | read-only | current | Channel Mismatch 94 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.202.1.4 | Columnpmopm2AlmChannel94BalancedPortn | read-only | current | Channel Balanced 94 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.202.1.5 | Columnpmopm2AlmChannel94PowerLowPortn | read-only | current | Channel Power Low 94 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.202.1.6 | Columnpmopm2AlmChannel94PowerHighPortn | read-only | current | Channel Power High 94 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.202.1.7 | Columnpmopm2AlmChannel94OosPortn | read-only | current | Channel Out Of Service 94 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL9… |
| 1.3.6.1.4.1.20044.64.2.2.3.204 | Tablepmopm2Almchannel95PortTable | not-accessible | current | List of pmopm2Almchannel95Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.204.1 | Rowpmopm2Almchannel95PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel95Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.204.1.1 | Columnpmopm2Almchannel95PortIndex | read-only | current | Index definition for the pmopm2Almchannel95Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.204.1.2 | Columnpmopm2AlmChannel95AbsentPortn | read-only | current | Channel Absent 95 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.204.1.3 | Columnpmopm2AlmChannel95MismatchPortn | read-only | current | Channel Mismatch 95 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.204.1.4 | Columnpmopm2AlmChannel95BalancedPortn | read-only | current | Channel Balanced 95 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.204.1.5 | Columnpmopm2AlmChannel95PowerLowPortn | read-only | current | Channel Power Low 95 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.204.1.6 | Columnpmopm2AlmChannel95PowerHighPortn | read-only | current | Channel Power High 95 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.204.1.7 | Columnpmopm2AlmChannel95OosPortn | read-only | current | Channel Out Of Service 95 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL9… |
| 1.3.6.1.4.1.20044.64.2.2.3.206 | Tablepmopm2Almchannel96PortTable | not-accessible | current | List of pmopm2Almchannel96Port Article |
| 1.3.6.1.4.1.20044.64.2.2.3.206.1 | Rowpmopm2Almchannel96PortEntry | not-accessible | current | Row definition for the pmopm2Almchannel96Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.206.1.1 | Columnpmopm2Almchannel96PortIndex | read-only | current | Index definition for the pmopm2Almchannel96Port table |
| 1.3.6.1.4.1.20044.64.2.2.3.206.1.2 | Columnpmopm2AlmChannel96AbsentPortn | read-only | current | Channel Absent 96 :This OID indicates that an in service channel is absent on the Optical Power Monitoring input<Help> This alarm indicates that an in service … |
| 1.3.6.1.4.1.20044.64.2.2.3.206.1.3 | Columnpmopm2AlmChannel96MismatchPortn | read-only | current | Channel Mismatch 96 :This OID indicates that an out of service channel is detected on the Optical Power Monitoring input<Help> This alarm indicates that an out… |
| 1.3.6.1.4.1.20044.64.2.2.3.206.1.4 | Columnpmopm2AlmChannel96BalancedPortn | read-only | current | Channel Balanced 96 :This OID indicates that an in service channel is balanced by the Ekinops auto turn up application<Help> This status indicates that an in s… |
| 1.3.6.1.4.1.20044.64.2.2.3.206.1.5 | Columnpmopm2AlmChannel96PowerLowPortn | read-only | current | Channel Power Low 96 :This OID indicates that the power of the channel is lower than the configured threshold<Help> This alarm indicates that the power of the … |
| 1.3.6.1.4.1.20044.64.2.2.3.206.1.6 | Columnpmopm2AlmChannel96PowerHighPortn | read-only | current | Channel Power High 96 :This OID indicates that the power of the channel is higher than the configured threshold<Help> This alarm indicates that the power of th… |
| 1.3.6.1.4.1.20044.64.2.2.3.206.1.7 | Columnpmopm2AlmChannel96OosPortn | read-only | current | Channel Out Of Service 96 :This OID indicates that the channel is out of service <Help> This alarm indicates that the channel is in service <Condtype> CHANNEL9… |
| 1.3.6.1.4.1.20044.64.2.3 | Nodepmopm2AlmLine | |||
| 1.3.6.1.4.1.20044.64.2.3.1 | Nodepmopm2AlmLineNurg | |||
| 1.3.6.1.4.1.20044.64.2.3.2 | Nodepmopm2AlmLineUrg | |||
| 1.3.6.1.4.1.20044.64.2.3.3 | Nodepmopm2AlmLineCrit | |||
| 1.3.6.1.4.1.20044.64.3 | Nodepmopm2measures | |||
| 1.3.6.1.4.1.20044.64.3.1 | Nodepmopm2MesrOther | |||
| 1.3.6.1.4.1.20044.64.3.1.248 | Scalarpmopm2MesropmTemp | read-only | current | PM OPM Temperature :This OID indicates the temperature of the PM OPM (Temperature = AV/256) (Unit = C)<Help> This measure indicates the temperature of the PM O… |
| 1.3.6.1.4.1.20044.64.3.2 | Nodepmopm2MesrClient | |||
| 1.3.6.1.4.1.20044.64.3.2.16 | Tablepmopm2Mesrchannel1Table | not-accessible | current | List of pmopm2Mesrchannel1 Article |
| 1.3.6.1.4.1.20044.64.3.2.16.1 | Rowpmopm2Mesrchannel1Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel1 table |
| 1.3.6.1.4.1.20044.64.3.2.16.1.1 | Columnpmopm2Mesrchannel1Index | read-only | current | Index definition for the pmopm2Mesrchannel1 table |
| 1.3.6.1.4.1.20044.64.3.2.16.1.2 | Columnpmopm2Mesrchannel1Portn | read-only | current | Channel Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.18 | Tablepmopm2Mesrchannel2Table | not-accessible | current | List of pmopm2Mesrchannel2 Article |
| 1.3.6.1.4.1.20044.64.3.2.18.1 | Rowpmopm2Mesrchannel2Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel2 table |
| 1.3.6.1.4.1.20044.64.3.2.18.1.1 | Columnpmopm2Mesrchannel2Index | read-only | current | Index definition for the pmopm2Mesrchannel2 table |
| 1.3.6.1.4.1.20044.64.3.2.18.1.2 | Columnpmopm2Mesrchannel2Portn | read-only | current | Channel2 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.20 | Tablepmopm2Mesrchannel3Table | not-accessible | current | List of pmopm2Mesrchannel3 Article |
| 1.3.6.1.4.1.20044.64.3.2.20.1 | Rowpmopm2Mesrchannel3Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel3 table |
| 1.3.6.1.4.1.20044.64.3.2.20.1.1 | Columnpmopm2Mesrchannel3Index | read-only | current | Index definition for the pmopm2Mesrchannel3 table |
| 1.3.6.1.4.1.20044.64.3.2.20.1.2 | Columnpmopm2Mesrchannel3Portn | read-only | current | Channel3 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.22 | Tablepmopm2Mesrchannel4Table | not-accessible | current | List of pmopm2Mesrchannel4 Article |
| 1.3.6.1.4.1.20044.64.3.2.22.1 | Rowpmopm2Mesrchannel4Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel4 table |
| 1.3.6.1.4.1.20044.64.3.2.22.1.1 | Columnpmopm2Mesrchannel4Index | read-only | current | Index definition for the pmopm2Mesrchannel4 table |
| 1.3.6.1.4.1.20044.64.3.2.22.1.2 | Columnpmopm2Mesrchannel4Portn | read-only | current | Channel4 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.24 | Tablepmopm2Mesrchannel5Table | not-accessible | current | List of pmopm2Mesrchannel5 Article |
| 1.3.6.1.4.1.20044.64.3.2.24.1 | Rowpmopm2Mesrchannel5Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel5 table |
| 1.3.6.1.4.1.20044.64.3.2.24.1.1 | Columnpmopm2Mesrchannel5Index | read-only | current | Index definition for the pmopm2Mesrchannel5 table |
| 1.3.6.1.4.1.20044.64.3.2.24.1.2 | Columnpmopm2Mesrchannel5Portn | read-only | current | Channel5 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.26 | Tablepmopm2Mesrchannel6Table | not-accessible | current | List of pmopm2Mesrchannel6 Article |
| 1.3.6.1.4.1.20044.64.3.2.26.1 | Rowpmopm2Mesrchannel6Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel6 table |
| 1.3.6.1.4.1.20044.64.3.2.26.1.1 | Columnpmopm2Mesrchannel6Index | read-only | current | Index definition for the pmopm2Mesrchannel6 table |
| 1.3.6.1.4.1.20044.64.3.2.26.1.2 | Columnpmopm2Mesrchannel6Portn | read-only | current | Channel6 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.28 | Tablepmopm2Mesrchannel7Table | not-accessible | current | List of pmopm2Mesrchannel7 Article |
| 1.3.6.1.4.1.20044.64.3.2.28.1 | Rowpmopm2Mesrchannel7Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel7 table |
| 1.3.6.1.4.1.20044.64.3.2.28.1.1 | Columnpmopm2Mesrchannel7Index | read-only | current | Index definition for the pmopm2Mesrchannel7 table |
| 1.3.6.1.4.1.20044.64.3.2.28.1.2 | Columnpmopm2Mesrchannel7Portn | read-only | current | Channel7 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.30 | Tablepmopm2Mesrchannel8Table | not-accessible | current | List of pmopm2Mesrchannel8 Article |
| 1.3.6.1.4.1.20044.64.3.2.30.1 | Rowpmopm2Mesrchannel8Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel8 table |
| 1.3.6.1.4.1.20044.64.3.2.30.1.1 | Columnpmopm2Mesrchannel8Index | read-only | current | Index definition for the pmopm2Mesrchannel8 table |
| 1.3.6.1.4.1.20044.64.3.2.30.1.2 | Columnpmopm2Mesrchannel8Portn | read-only | current | Channel8 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.32 | Tablepmopm2Mesrchannel9Table | not-accessible | current | List of pmopm2Mesrchannel9 Article |
| 1.3.6.1.4.1.20044.64.3.2.32.1 | Rowpmopm2Mesrchannel9Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel9 table |
| 1.3.6.1.4.1.20044.64.3.2.32.1.1 | Columnpmopm2Mesrchannel9Index | read-only | current | Index definition for the pmopm2Mesrchannel9 table |
| 1.3.6.1.4.1.20044.64.3.2.32.1.2 | Columnpmopm2Mesrchannel9Portn | read-only | current | Channel9 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.34 | Tablepmopm2Mesrchannel10Table | not-accessible | current | List of pmopm2Mesrchannel10 Article |
| 1.3.6.1.4.1.20044.64.3.2.34.1 | Rowpmopm2Mesrchannel10Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel10 table |
| 1.3.6.1.4.1.20044.64.3.2.34.1.1 | Columnpmopm2Mesrchannel10Index | read-only | current | Index definition for the pmopm2Mesrchannel10 table |
| 1.3.6.1.4.1.20044.64.3.2.34.1.2 | Columnpmopm2Mesrchannel10Portn | read-only | current | Channel10 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.36 | Tablepmopm2Mesrchannel11Table | not-accessible | current | List of pmopm2Mesrchannel11 Article |
| 1.3.6.1.4.1.20044.64.3.2.36.1 | Rowpmopm2Mesrchannel11Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel11 table |
| 1.3.6.1.4.1.20044.64.3.2.36.1.1 | Columnpmopm2Mesrchannel11Index | read-only | current | Index definition for the pmopm2Mesrchannel11 table |
| 1.3.6.1.4.1.20044.64.3.2.36.1.2 | Columnpmopm2Mesrchannel11Portn | read-only | current | Channel11 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.38 | Tablepmopm2Mesrchannel12Table | not-accessible | current | List of pmopm2Mesrchannel12 Article |
| 1.3.6.1.4.1.20044.64.3.2.38.1 | Rowpmopm2Mesrchannel12Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel12 table |
| 1.3.6.1.4.1.20044.64.3.2.38.1.1 | Columnpmopm2Mesrchannel12Index | read-only | current | Index definition for the pmopm2Mesrchannel12 table |
| 1.3.6.1.4.1.20044.64.3.2.38.1.2 | Columnpmopm2Mesrchannel12Portn | read-only | current | Channel12 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.40 | Tablepmopm2Mesrchannel13Table | not-accessible | current | List of pmopm2Mesrchannel13 Article |
| 1.3.6.1.4.1.20044.64.3.2.40.1 | Rowpmopm2Mesrchannel13Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel13 table |
| 1.3.6.1.4.1.20044.64.3.2.40.1.1 | Columnpmopm2Mesrchannel13Index | read-only | current | Index definition for the pmopm2Mesrchannel13 table |
| 1.3.6.1.4.1.20044.64.3.2.40.1.2 | Columnpmopm2Mesrchannel13Portn | read-only | current | Channel13 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.42 | Tablepmopm2Mesrchannel14Table | not-accessible | current | List of pmopm2Mesrchannel14 Article |
| 1.3.6.1.4.1.20044.64.3.2.42.1 | Rowpmopm2Mesrchannel14Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel14 table |
| 1.3.6.1.4.1.20044.64.3.2.42.1.1 | Columnpmopm2Mesrchannel14Index | read-only | current | Index definition for the pmopm2Mesrchannel14 table |
| 1.3.6.1.4.1.20044.64.3.2.42.1.2 | Columnpmopm2Mesrchannel14Portn | read-only | current | Channel14 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.44 | Tablepmopm2Mesrchannel15Table | not-accessible | current | List of pmopm2Mesrchannel15 Article |
| 1.3.6.1.4.1.20044.64.3.2.44.1 | Rowpmopm2Mesrchannel15Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel15 table |
| 1.3.6.1.4.1.20044.64.3.2.44.1.1 | Columnpmopm2Mesrchannel15Index | read-only | current | Index definition for the pmopm2Mesrchannel15 table |
| 1.3.6.1.4.1.20044.64.3.2.44.1.2 | Columnpmopm2Mesrchannel15Portn | read-only | current | Channel15 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.46 | Tablepmopm2Mesrchannel16Table | not-accessible | current | List of pmopm2Mesrchannel16 Article |
| 1.3.6.1.4.1.20044.64.3.2.46.1 | Rowpmopm2Mesrchannel16Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel16 table |
| 1.3.6.1.4.1.20044.64.3.2.46.1.1 | Columnpmopm2Mesrchannel16Index | read-only | current | Index definition for the pmopm2Mesrchannel16 table |
| 1.3.6.1.4.1.20044.64.3.2.46.1.2 | Columnpmopm2Mesrchannel16Portn | read-only | current | Channel16 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.48 | Tablepmopm2Mesrchannel17Table | not-accessible | current | List of pmopm2Mesrchannel17 Article |
| 1.3.6.1.4.1.20044.64.3.2.48.1 | Rowpmopm2Mesrchannel17Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel17 table |
| 1.3.6.1.4.1.20044.64.3.2.48.1.1 | Columnpmopm2Mesrchannel17Index | read-only | current | Index definition for the pmopm2Mesrchannel17 table |
| 1.3.6.1.4.1.20044.64.3.2.48.1.2 | Columnpmopm2Mesrchannel17Portn | read-only | current | Channel17 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.50 | Tablepmopm2Mesrchannel18Table | not-accessible | current | List of pmopm2Mesrchannel18 Article |
| 1.3.6.1.4.1.20044.64.3.2.50.1 | Rowpmopm2Mesrchannel18Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel18 table |
| 1.3.6.1.4.1.20044.64.3.2.50.1.1 | Columnpmopm2Mesrchannel18Index | read-only | current | Index definition for the pmopm2Mesrchannel18 table |
| 1.3.6.1.4.1.20044.64.3.2.50.1.2 | Columnpmopm2Mesrchannel18Portn | read-only | current | Channel18 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.52 | Tablepmopm2Mesrchannel19Table | not-accessible | current | List of pmopm2Mesrchannel19 Article |
| 1.3.6.1.4.1.20044.64.3.2.52.1 | Rowpmopm2Mesrchannel19Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel19 table |
| 1.3.6.1.4.1.20044.64.3.2.52.1.1 | Columnpmopm2Mesrchannel19Index | read-only | current | Index definition for the pmopm2Mesrchannel19 table |
| 1.3.6.1.4.1.20044.64.3.2.52.1.2 | Columnpmopm2Mesrchannel19Portn | read-only | current | Channel19 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.54 | Tablepmopm2Mesrchannel20Table | not-accessible | current | List of pmopm2Mesrchannel20 Article |
| 1.3.6.1.4.1.20044.64.3.2.54.1 | Rowpmopm2Mesrchannel20Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel20 table |
| 1.3.6.1.4.1.20044.64.3.2.54.1.1 | Columnpmopm2Mesrchannel20Index | read-only | current | Index definition for the pmopm2Mesrchannel20 table |
| 1.3.6.1.4.1.20044.64.3.2.54.1.2 | Columnpmopm2Mesrchannel20Portn | read-only | current | Channel20 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.56 | Tablepmopm2Mesrchannel21Table | not-accessible | current | List of pmopm2Mesrchannel21 Article |
| 1.3.6.1.4.1.20044.64.3.2.56.1 | Rowpmopm2Mesrchannel21Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel21 table |
| 1.3.6.1.4.1.20044.64.3.2.56.1.1 | Columnpmopm2Mesrchannel21Index | read-only | current | Index definition for the pmopm2Mesrchannel21 table |
| 1.3.6.1.4.1.20044.64.3.2.56.1.2 | Columnpmopm2Mesrchannel21Portn | read-only | current | Channel21 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.58 | Tablepmopm2Mesrchannel22Table | not-accessible | current | List of pmopm2Mesrchannel22 Article |
| 1.3.6.1.4.1.20044.64.3.2.58.1 | Rowpmopm2Mesrchannel22Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel22 table |
| 1.3.6.1.4.1.20044.64.3.2.58.1.1 | Columnpmopm2Mesrchannel22Index | read-only | current | Index definition for the pmopm2Mesrchannel22 table |
| 1.3.6.1.4.1.20044.64.3.2.58.1.2 | Columnpmopm2Mesrchannel22Portn | read-only | current | Channel22 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.60 | Tablepmopm2Mesrchannel23Table | not-accessible | current | List of pmopm2Mesrchannel23 Article |
| 1.3.6.1.4.1.20044.64.3.2.60.1 | Rowpmopm2Mesrchannel23Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel23 table |
| 1.3.6.1.4.1.20044.64.3.2.60.1.1 | Columnpmopm2Mesrchannel23Index | read-only | current | Index definition for the pmopm2Mesrchannel23 table |
| 1.3.6.1.4.1.20044.64.3.2.60.1.2 | Columnpmopm2Mesrchannel23Portn | read-only | current | Channel23 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.62 | Tablepmopm2Mesrchannel24Table | not-accessible | current | List of pmopm2Mesrchannel24 Article |
| 1.3.6.1.4.1.20044.64.3.2.62.1 | Rowpmopm2Mesrchannel24Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel24 table |
| 1.3.6.1.4.1.20044.64.3.2.62.1.1 | Columnpmopm2Mesrchannel24Index | read-only | current | Index definition for the pmopm2Mesrchannel24 table |
| 1.3.6.1.4.1.20044.64.3.2.62.1.2 | Columnpmopm2Mesrchannel24Portn | read-only | current | Channel24 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.64 | Tablepmopm2Mesrchannel25Table | not-accessible | current | List of pmopm2Mesrchannel25 Article |
| 1.3.6.1.4.1.20044.64.3.2.64.1 | Rowpmopm2Mesrchannel25Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel25 table |
| 1.3.6.1.4.1.20044.64.3.2.64.1.1 | Columnpmopm2Mesrchannel25Index | read-only | current | Index definition for the pmopm2Mesrchannel25 table |
| 1.3.6.1.4.1.20044.64.3.2.64.1.2 | Columnpmopm2Mesrchannel25Portn | read-only | current | Channel25 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.66 | Tablepmopm2Mesrchannel26Table | not-accessible | current | List of pmopm2Mesrchannel26 Article |
| 1.3.6.1.4.1.20044.64.3.2.66.1 | Rowpmopm2Mesrchannel26Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel26 table |
| 1.3.6.1.4.1.20044.64.3.2.66.1.1 | Columnpmopm2Mesrchannel26Index | read-only | current | Index definition for the pmopm2Mesrchannel26 table |
| 1.3.6.1.4.1.20044.64.3.2.66.1.2 | Columnpmopm2Mesrchannel26Portn | read-only | current | Channel26 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.68 | Tablepmopm2Mesrchannel27Table | not-accessible | current | List of pmopm2Mesrchannel27 Article |
| 1.3.6.1.4.1.20044.64.3.2.68.1 | Rowpmopm2Mesrchannel27Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel27 table |
| 1.3.6.1.4.1.20044.64.3.2.68.1.1 | Columnpmopm2Mesrchannel27Index | read-only | current | Index definition for the pmopm2Mesrchannel27 table |
| 1.3.6.1.4.1.20044.64.3.2.68.1.2 | Columnpmopm2Mesrchannel27Portn | read-only | current | Channel27 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.70 | Tablepmopm2Mesrchannel28Table | not-accessible | current | List of pmopm2Mesrchannel28 Article |
| 1.3.6.1.4.1.20044.64.3.2.70.1 | Rowpmopm2Mesrchannel28Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel28 table |
| 1.3.6.1.4.1.20044.64.3.2.70.1.1 | Columnpmopm2Mesrchannel28Index | read-only | current | Index definition for the pmopm2Mesrchannel28 table |
| 1.3.6.1.4.1.20044.64.3.2.70.1.2 | Columnpmopm2Mesrchannel28Portn | read-only | current | Channel28 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.72 | Tablepmopm2Mesrchannel29Table | not-accessible | current | List of pmopm2Mesrchannel29 Article |
| 1.3.6.1.4.1.20044.64.3.2.72.1 | Rowpmopm2Mesrchannel29Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel29 table |
| 1.3.6.1.4.1.20044.64.3.2.72.1.1 | Columnpmopm2Mesrchannel29Index | read-only | current | Index definition for the pmopm2Mesrchannel29 table |
| 1.3.6.1.4.1.20044.64.3.2.72.1.2 | Columnpmopm2Mesrchannel29Portn | read-only | current | Channel29 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.74 | Tablepmopm2Mesrchannel30Table | not-accessible | current | List of pmopm2Mesrchannel30 Article |
| 1.3.6.1.4.1.20044.64.3.2.74.1 | Rowpmopm2Mesrchannel30Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel30 table |
| 1.3.6.1.4.1.20044.64.3.2.74.1.1 | Columnpmopm2Mesrchannel30Index | read-only | current | Index definition for the pmopm2Mesrchannel30 table |
| 1.3.6.1.4.1.20044.64.3.2.74.1.2 | Columnpmopm2Mesrchannel30Portn | read-only | current | Channel30 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.76 | Tablepmopm2Mesrchannel31Table | not-accessible | current | List of pmopm2Mesrchannel31 Article |
| 1.3.6.1.4.1.20044.64.3.2.76.1 | Rowpmopm2Mesrchannel31Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel31 table |
| 1.3.6.1.4.1.20044.64.3.2.76.1.1 | Columnpmopm2Mesrchannel31Index | read-only | current | Index definition for the pmopm2Mesrchannel31 table |
| 1.3.6.1.4.1.20044.64.3.2.76.1.2 | Columnpmopm2Mesrchannel31Portn | read-only | current | Channel31 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.78 | Tablepmopm2Mesrchannel32Table | not-accessible | current | List of pmopm2Mesrchannel32 Article |
| 1.3.6.1.4.1.20044.64.3.2.78.1 | Rowpmopm2Mesrchannel32Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel32 table |
| 1.3.6.1.4.1.20044.64.3.2.78.1.1 | Columnpmopm2Mesrchannel32Index | read-only | current | Index definition for the pmopm2Mesrchannel32 table |
| 1.3.6.1.4.1.20044.64.3.2.78.1.2 | Columnpmopm2Mesrchannel32Portn | read-only | current | Channel32 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.80 | Tablepmopm2Mesrchannel33Table | not-accessible | current | List of pmopm2Mesrchannel33 Article |
| 1.3.6.1.4.1.20044.64.3.2.80.1 | Rowpmopm2Mesrchannel33Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel33 table |
| 1.3.6.1.4.1.20044.64.3.2.80.1.1 | Columnpmopm2Mesrchannel33Index | read-only | current | Index definition for the pmopm2Mesrchannel33 table |
| 1.3.6.1.4.1.20044.64.3.2.80.1.2 | Columnpmopm2Mesrchannel33Portn | read-only | current | Channel33 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.82 | Tablepmopm2Mesrchannel34Table | not-accessible | current | List of pmopm2Mesrchannel34 Article |
| 1.3.6.1.4.1.20044.64.3.2.82.1 | Rowpmopm2Mesrchannel34Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel34 table |
| 1.3.6.1.4.1.20044.64.3.2.82.1.1 | Columnpmopm2Mesrchannel34Index | read-only | current | Index definition for the pmopm2Mesrchannel34 table |
| 1.3.6.1.4.1.20044.64.3.2.82.1.2 | Columnpmopm2Mesrchannel34Portn | read-only | current | Channel34 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.84 | Tablepmopm2Mesrchannel35Table | not-accessible | current | List of pmopm2Mesrchannel35 Article |
| 1.3.6.1.4.1.20044.64.3.2.84.1 | Rowpmopm2Mesrchannel35Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel35 table |
| 1.3.6.1.4.1.20044.64.3.2.84.1.1 | Columnpmopm2Mesrchannel35Index | read-only | current | Index definition for the pmopm2Mesrchannel35 table |
| 1.3.6.1.4.1.20044.64.3.2.84.1.2 | Columnpmopm2Mesrchannel35Portn | read-only | current | Channel35 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.86 | Tablepmopm2Mesrchannel36Table | not-accessible | current | List of pmopm2Mesrchannel36 Article |
| 1.3.6.1.4.1.20044.64.3.2.86.1 | Rowpmopm2Mesrchannel36Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel36 table |
| 1.3.6.1.4.1.20044.64.3.2.86.1.1 | Columnpmopm2Mesrchannel36Index | read-only | current | Index definition for the pmopm2Mesrchannel36 table |
| 1.3.6.1.4.1.20044.64.3.2.86.1.2 | Columnpmopm2Mesrchannel36Portn | read-only | current | Channel36 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.88 | Tablepmopm2Mesrchannel37Table | not-accessible | current | List of pmopm2Mesrchannel37 Article |
| 1.3.6.1.4.1.20044.64.3.2.88.1 | Rowpmopm2Mesrchannel37Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel37 table |
| 1.3.6.1.4.1.20044.64.3.2.88.1.1 | Columnpmopm2Mesrchannel37Index | read-only | current | Index definition for the pmopm2Mesrchannel37 table |
| 1.3.6.1.4.1.20044.64.3.2.88.1.2 | Columnpmopm2Mesrchannel37Portn | read-only | current | Channel37 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.90 | Tablepmopm2Mesrchannel38Table | not-accessible | current | List of pmopm2Mesrchannel38 Article |
| 1.3.6.1.4.1.20044.64.3.2.90.1 | Rowpmopm2Mesrchannel38Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel38 table |
| 1.3.6.1.4.1.20044.64.3.2.90.1.1 | Columnpmopm2Mesrchannel38Index | read-only | current | Index definition for the pmopm2Mesrchannel38 table |
| 1.3.6.1.4.1.20044.64.3.2.90.1.2 | Columnpmopm2Mesrchannel38Portn | read-only | current | Channel38 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.92 | Tablepmopm2Mesrchannel39Table | not-accessible | current | List of pmopm2Mesrchannel39 Article |
| 1.3.6.1.4.1.20044.64.3.2.92.1 | Rowpmopm2Mesrchannel39Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel39 table |
| 1.3.6.1.4.1.20044.64.3.2.92.1.1 | Columnpmopm2Mesrchannel39Index | read-only | current | Index definition for the pmopm2Mesrchannel39 table |
| 1.3.6.1.4.1.20044.64.3.2.92.1.2 | Columnpmopm2Mesrchannel39Portn | read-only | current | Channel39 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.94 | Tablepmopm2Mesrchannel40Table | not-accessible | current | List of pmopm2Mesrchannel40 Article |
| 1.3.6.1.4.1.20044.64.3.2.94.1 | Rowpmopm2Mesrchannel40Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel40 table |
| 1.3.6.1.4.1.20044.64.3.2.94.1.1 | Columnpmopm2Mesrchannel40Index | read-only | current | Index definition for the pmopm2Mesrchannel40 table |
| 1.3.6.1.4.1.20044.64.3.2.94.1.2 | Columnpmopm2Mesrchannel40Portn | read-only | current | Channel40 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.96 | Tablepmopm2Mesrchannel41Table | not-accessible | current | List of pmopm2Mesrchannel41 Article |
| 1.3.6.1.4.1.20044.64.3.2.96.1 | Rowpmopm2Mesrchannel41Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel41 table |
| 1.3.6.1.4.1.20044.64.3.2.96.1.1 | Columnpmopm2Mesrchannel41Index | read-only | current | Index definition for the pmopm2Mesrchannel41 table |
| 1.3.6.1.4.1.20044.64.3.2.96.1.2 | Columnpmopm2Mesrchannel41Portn | read-only | current | Channel41 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.98 | Tablepmopm2Mesrchannel42Table | not-accessible | current | List of pmopm2Mesrchannel42 Article |
| 1.3.6.1.4.1.20044.64.3.2.98.1 | Rowpmopm2Mesrchannel42Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel42 table |
| 1.3.6.1.4.1.20044.64.3.2.98.1.1 | Columnpmopm2Mesrchannel42Index | read-only | current | Index definition for the pmopm2Mesrchannel42 table |
| 1.3.6.1.4.1.20044.64.3.2.98.1.2 | Columnpmopm2Mesrchannel42Portn | read-only | current | Channel42 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.100 | Tablepmopm2Mesrchannel43Table | not-accessible | current | List of pmopm2Mesrchannel43 Article |
| 1.3.6.1.4.1.20044.64.3.2.100.1 | Rowpmopm2Mesrchannel43Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel43 table |
| 1.3.6.1.4.1.20044.64.3.2.100.1.1 | Columnpmopm2Mesrchannel43Index | read-only | current | Index definition for the pmopm2Mesrchannel43 table |
| 1.3.6.1.4.1.20044.64.3.2.100.1.2 | Columnpmopm2Mesrchannel43Portn | read-only | current | Channel43 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.102 | Tablepmopm2Mesrchannel44Table | not-accessible | current | List of pmopm2Mesrchannel44 Article |
| 1.3.6.1.4.1.20044.64.3.2.102.1 | Rowpmopm2Mesrchannel44Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel44 table |
| 1.3.6.1.4.1.20044.64.3.2.102.1.1 | Columnpmopm2Mesrchannel44Index | read-only | current | Index definition for the pmopm2Mesrchannel44 table |
| 1.3.6.1.4.1.20044.64.3.2.102.1.2 | Columnpmopm2Mesrchannel44Portn | read-only | current | Channel44 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.104 | Tablepmopm2Mesrchannel45Table | not-accessible | current | List of pmopm2Mesrchannel45 Article |
| 1.3.6.1.4.1.20044.64.3.2.104.1 | Rowpmopm2Mesrchannel45Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel45 table |
| 1.3.6.1.4.1.20044.64.3.2.104.1.1 | Columnpmopm2Mesrchannel45Index | read-only | current | Index definition for the pmopm2Mesrchannel45 table |
| 1.3.6.1.4.1.20044.64.3.2.104.1.2 | Columnpmopm2Mesrchannel45Portn | read-only | current | Channel45 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.106 | Tablepmopm2Mesrchannel46Table | not-accessible | current | List of pmopm2Mesrchannel46 Article |
| 1.3.6.1.4.1.20044.64.3.2.106.1 | Rowpmopm2Mesrchannel46Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel46 table |
| 1.3.6.1.4.1.20044.64.3.2.106.1.1 | Columnpmopm2Mesrchannel46Index | read-only | current | Index definition for the pmopm2Mesrchannel46 table |
| 1.3.6.1.4.1.20044.64.3.2.106.1.2 | Columnpmopm2Mesrchannel46Portn | read-only | current | Channel46 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.108 | Tablepmopm2Mesrchannel47Table | not-accessible | current | List of pmopm2Mesrchannel47 Article |
| 1.3.6.1.4.1.20044.64.3.2.108.1 | Rowpmopm2Mesrchannel47Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel47 table |
| 1.3.6.1.4.1.20044.64.3.2.108.1.1 | Columnpmopm2Mesrchannel47Index | read-only | current | Index definition for the pmopm2Mesrchannel47 table |
| 1.3.6.1.4.1.20044.64.3.2.108.1.2 | Columnpmopm2Mesrchannel47Portn | read-only | current | Channel47 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.110 | Tablepmopm2Mesrchannel48Table | not-accessible | current | List of pmopm2Mesrchannel48 Article |
| 1.3.6.1.4.1.20044.64.3.2.110.1 | Rowpmopm2Mesrchannel48Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel48 table |
| 1.3.6.1.4.1.20044.64.3.2.110.1.1 | Columnpmopm2Mesrchannel48Index | read-only | current | Index definition for the pmopm2Mesrchannel48 table |
| 1.3.6.1.4.1.20044.64.3.2.110.1.2 | Columnpmopm2Mesrchannel48Portn | read-only | current | Channel48 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.112 | Tablepmopm2Mesrchannel49Table | not-accessible | current | List of pmopm2Mesrchannel49 Article |
| 1.3.6.1.4.1.20044.64.3.2.112.1 | Rowpmopm2Mesrchannel49Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel49 table |
| 1.3.6.1.4.1.20044.64.3.2.112.1.1 | Columnpmopm2Mesrchannel49Index | read-only | current | Index definition for the pmopm2Mesrchannel49 table |
| 1.3.6.1.4.1.20044.64.3.2.112.1.2 | Columnpmopm2Mesrchannel49Portn | read-only | current | Channel49 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.114 | Tablepmopm2Mesrchannel50Table | not-accessible | current | List of pmopm2Mesrchannel50 Article |
| 1.3.6.1.4.1.20044.64.3.2.114.1 | Rowpmopm2Mesrchannel50Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel50 table |
| 1.3.6.1.4.1.20044.64.3.2.114.1.1 | Columnpmopm2Mesrchannel50Index | read-only | current | Index definition for the pmopm2Mesrchannel50 table |
| 1.3.6.1.4.1.20044.64.3.2.114.1.2 | Columnpmopm2Mesrchannel50Portn | read-only | current | Channel50 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.116 | Tablepmopm2Mesrchannel51Table | not-accessible | current | List of pmopm2Mesrchannel51 Article |
| 1.3.6.1.4.1.20044.64.3.2.116.1 | Rowpmopm2Mesrchannel51Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel51 table |
| 1.3.6.1.4.1.20044.64.3.2.116.1.1 | Columnpmopm2Mesrchannel51Index | read-only | current | Index definition for the pmopm2Mesrchannel51 table |
| 1.3.6.1.4.1.20044.64.3.2.116.1.2 | Columnpmopm2Mesrchannel51Portn | read-only | current | Channel51 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.118 | Tablepmopm2Mesrchannel52Table | not-accessible | current | List of pmopm2Mesrchannel52 Article |
| 1.3.6.1.4.1.20044.64.3.2.118.1 | Rowpmopm2Mesrchannel52Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel52 table |
| 1.3.6.1.4.1.20044.64.3.2.118.1.1 | Columnpmopm2Mesrchannel52Index | read-only | current | Index definition for the pmopm2Mesrchannel52 table |
| 1.3.6.1.4.1.20044.64.3.2.118.1.2 | Columnpmopm2Mesrchannel52Portn | read-only | current | Channel52 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.120 | Tablepmopm2Mesrchannel53Table | not-accessible | current | List of pmopm2Mesrchannel53 Article |
| 1.3.6.1.4.1.20044.64.3.2.120.1 | Rowpmopm2Mesrchannel53Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel53 table |
| 1.3.6.1.4.1.20044.64.3.2.120.1.1 | Columnpmopm2Mesrchannel53Index | read-only | current | Index definition for the pmopm2Mesrchannel53 table |
| 1.3.6.1.4.1.20044.64.3.2.120.1.2 | Columnpmopm2Mesrchannel53Portn | read-only | current | Channel53 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.122 | Tablepmopm2Mesrchannel54Table | not-accessible | current | List of pmopm2Mesrchannel54 Article |
| 1.3.6.1.4.1.20044.64.3.2.122.1 | Rowpmopm2Mesrchannel54Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel54 table |
| 1.3.6.1.4.1.20044.64.3.2.122.1.1 | Columnpmopm2Mesrchannel54Index | read-only | current | Index definition for the pmopm2Mesrchannel54 table |
| 1.3.6.1.4.1.20044.64.3.2.122.1.2 | Columnpmopm2Mesrchannel54Portn | read-only | current | Channel54 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.124 | Tablepmopm2Mesrchannel55Table | not-accessible | current | List of pmopm2Mesrchannel55 Article |
| 1.3.6.1.4.1.20044.64.3.2.124.1 | Rowpmopm2Mesrchannel55Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel55 table |
| 1.3.6.1.4.1.20044.64.3.2.124.1.1 | Columnpmopm2Mesrchannel55Index | read-only | current | Index definition for the pmopm2Mesrchannel55 table |
| 1.3.6.1.4.1.20044.64.3.2.124.1.2 | Columnpmopm2Mesrchannel55Portn | read-only | current | Channel55 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.126 | Tablepmopm2Mesrchannel56Table | not-accessible | current | List of pmopm2Mesrchannel56 Article |
| 1.3.6.1.4.1.20044.64.3.2.126.1 | Rowpmopm2Mesrchannel56Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel56 table |
| 1.3.6.1.4.1.20044.64.3.2.126.1.1 | Columnpmopm2Mesrchannel56Index | read-only | current | Index definition for the pmopm2Mesrchannel56 table |
| 1.3.6.1.4.1.20044.64.3.2.126.1.2 | Columnpmopm2Mesrchannel56Portn | read-only | current | Channel56 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.128 | Tablepmopm2Mesrchannel57Table | not-accessible | current | List of pmopm2Mesrchannel57 Article |
| 1.3.6.1.4.1.20044.64.3.2.128.1 | Rowpmopm2Mesrchannel57Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel57 table |
| 1.3.6.1.4.1.20044.64.3.2.128.1.1 | Columnpmopm2Mesrchannel57Index | read-only | current | Index definition for the pmopm2Mesrchannel57 table |
| 1.3.6.1.4.1.20044.64.3.2.128.1.2 | Columnpmopm2Mesrchannel57Portn | read-only | current | Channel57 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.130 | Tablepmopm2Mesrchannel58Table | not-accessible | current | List of pmopm2Mesrchannel58 Article |
| 1.3.6.1.4.1.20044.64.3.2.130.1 | Rowpmopm2Mesrchannel58Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel58 table |
| 1.3.6.1.4.1.20044.64.3.2.130.1.1 | Columnpmopm2Mesrchannel58Index | read-only | current | Index definition for the pmopm2Mesrchannel58 table |
| 1.3.6.1.4.1.20044.64.3.2.130.1.2 | Columnpmopm2Mesrchannel58Portn | read-only | current | Channel58 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.132 | Tablepmopm2Mesrchannel59Table | not-accessible | current | List of pmopm2Mesrchannel59 Article |
| 1.3.6.1.4.1.20044.64.3.2.132.1 | Rowpmopm2Mesrchannel59Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel59 table |
| 1.3.6.1.4.1.20044.64.3.2.132.1.1 | Columnpmopm2Mesrchannel59Index | read-only | current | Index definition for the pmopm2Mesrchannel59 table |
| 1.3.6.1.4.1.20044.64.3.2.132.1.2 | Columnpmopm2Mesrchannel59Portn | read-only | current | Channel59 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.134 | Tablepmopm2Mesrchannel60Table | not-accessible | current | List of pmopm2Mesrchannel60 Article |
| 1.3.6.1.4.1.20044.64.3.2.134.1 | Rowpmopm2Mesrchannel60Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel60 table |
| 1.3.6.1.4.1.20044.64.3.2.134.1.1 | Columnpmopm2Mesrchannel60Index | read-only | current | Index definition for the pmopm2Mesrchannel60 table |
| 1.3.6.1.4.1.20044.64.3.2.134.1.2 | Columnpmopm2Mesrchannel60Portn | read-only | current | Channel60 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.136 | Tablepmopm2Mesrchannel61Table | not-accessible | current | List of pmopm2Mesrchannel61 Article |
| 1.3.6.1.4.1.20044.64.3.2.136.1 | Rowpmopm2Mesrchannel61Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel61 table |
| 1.3.6.1.4.1.20044.64.3.2.136.1.1 | Columnpmopm2Mesrchannel61Index | read-only | current | Index definition for the pmopm2Mesrchannel61 table |
| 1.3.6.1.4.1.20044.64.3.2.136.1.2 | Columnpmopm2Mesrchannel61Portn | read-only | current | Channel61 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.138 | Tablepmopm2Mesrchannel62Table | not-accessible | current | List of pmopm2Mesrchannel62 Article |
| 1.3.6.1.4.1.20044.64.3.2.138.1 | Rowpmopm2Mesrchannel62Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel62 table |
| 1.3.6.1.4.1.20044.64.3.2.138.1.1 | Columnpmopm2Mesrchannel62Index | read-only | current | Index definition for the pmopm2Mesrchannel62 table |
| 1.3.6.1.4.1.20044.64.3.2.138.1.2 | Columnpmopm2Mesrchannel62Portn | read-only | current | Channel62 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.140 | Tablepmopm2Mesrchannel63Table | not-accessible | current | List of pmopm2Mesrchannel63 Article |
| 1.3.6.1.4.1.20044.64.3.2.140.1 | Rowpmopm2Mesrchannel63Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel63 table |
| 1.3.6.1.4.1.20044.64.3.2.140.1.1 | Columnpmopm2Mesrchannel63Index | read-only | current | Index definition for the pmopm2Mesrchannel63 table |
| 1.3.6.1.4.1.20044.64.3.2.140.1.2 | Columnpmopm2Mesrchannel63Portn | read-only | current | Channel63 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.142 | Tablepmopm2Mesrchannel64Table | not-accessible | current | List of pmopm2Mesrchannel64 Article |
| 1.3.6.1.4.1.20044.64.3.2.142.1 | Rowpmopm2Mesrchannel64Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel64 table |
| 1.3.6.1.4.1.20044.64.3.2.142.1.1 | Columnpmopm2Mesrchannel64Index | read-only | current | Index definition for the pmopm2Mesrchannel64 table |
| 1.3.6.1.4.1.20044.64.3.2.142.1.2 | Columnpmopm2Mesrchannel64Portn | read-only | current | Channel64 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.144 | Tablepmopm2Mesrchannel65Table | not-accessible | current | List of pmopm2Mesrchannel65 Article |
| 1.3.6.1.4.1.20044.64.3.2.144.1 | Rowpmopm2Mesrchannel65Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel65 table |
| 1.3.6.1.4.1.20044.64.3.2.144.1.1 | Columnpmopm2Mesrchannel65Index | read-only | current | Index definition for the pmopm2Mesrchannel65 table |
| 1.3.6.1.4.1.20044.64.3.2.144.1.2 | Columnpmopm2Mesrchannel65Portn | read-only | current | Channel65 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.146 | Tablepmopm2Mesrchannel66Table | not-accessible | current | List of pmopm2Mesrchannel66 Article |
| 1.3.6.1.4.1.20044.64.3.2.146.1 | Rowpmopm2Mesrchannel66Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel66 table |
| 1.3.6.1.4.1.20044.64.3.2.146.1.1 | Columnpmopm2Mesrchannel66Index | read-only | current | Index definition for the pmopm2Mesrchannel66 table |
| 1.3.6.1.4.1.20044.64.3.2.146.1.2 | Columnpmopm2Mesrchannel66Portn | read-only | current | Channel66 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.148 | Tablepmopm2Mesrchannel67Table | not-accessible | current | List of pmopm2Mesrchannel67 Article |
| 1.3.6.1.4.1.20044.64.3.2.148.1 | Rowpmopm2Mesrchannel67Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel67 table |
| 1.3.6.1.4.1.20044.64.3.2.148.1.1 | Columnpmopm2Mesrchannel67Index | read-only | current | Index definition for the pmopm2Mesrchannel67 table |
| 1.3.6.1.4.1.20044.64.3.2.148.1.2 | Columnpmopm2Mesrchannel67Portn | read-only | current | Channel67 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.150 | Tablepmopm2Mesrchannel68Table | not-accessible | current | List of pmopm2Mesrchannel68 Article |
| 1.3.6.1.4.1.20044.64.3.2.150.1 | Rowpmopm2Mesrchannel68Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel68 table |
| 1.3.6.1.4.1.20044.64.3.2.150.1.1 | Columnpmopm2Mesrchannel68Index | read-only | current | Index definition for the pmopm2Mesrchannel68 table |
| 1.3.6.1.4.1.20044.64.3.2.150.1.2 | Columnpmopm2Mesrchannel68Portn | read-only | current | Channel68 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.152 | Tablepmopm2Mesrchannel69Table | not-accessible | current | List of pmopm2Mesrchannel69 Article |
| 1.3.6.1.4.1.20044.64.3.2.152.1 | Rowpmopm2Mesrchannel69Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel69 table |
| 1.3.6.1.4.1.20044.64.3.2.152.1.1 | Columnpmopm2Mesrchannel69Index | read-only | current | Index definition for the pmopm2Mesrchannel69 table |
| 1.3.6.1.4.1.20044.64.3.2.152.1.2 | Columnpmopm2Mesrchannel69Portn | read-only | current | Channel69 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.154 | Tablepmopm2Mesrchannel70Table | not-accessible | current | List of pmopm2Mesrchannel70 Article |
| 1.3.6.1.4.1.20044.64.3.2.154.1 | Rowpmopm2Mesrchannel70Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel70 table |
| 1.3.6.1.4.1.20044.64.3.2.154.1.1 | Columnpmopm2Mesrchannel70Index | read-only | current | Index definition for the pmopm2Mesrchannel70 table |
| 1.3.6.1.4.1.20044.64.3.2.154.1.2 | Columnpmopm2Mesrchannel70Portn | read-only | current | Channel70 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.156 | Tablepmopm2Mesrchannel71Table | not-accessible | current | List of pmopm2Mesrchannel71 Article |
| 1.3.6.1.4.1.20044.64.3.2.156.1 | Rowpmopm2Mesrchannel71Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel71 table |
| 1.3.6.1.4.1.20044.64.3.2.156.1.1 | Columnpmopm2Mesrchannel71Index | read-only | current | Index definition for the pmopm2Mesrchannel71 table |
| 1.3.6.1.4.1.20044.64.3.2.156.1.2 | Columnpmopm2Mesrchannel71Portn | read-only | current | Channel71 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.158 | Tablepmopm2Mesrchannel72Table | not-accessible | current | List of pmopm2Mesrchannel72 Article |
| 1.3.6.1.4.1.20044.64.3.2.158.1 | Rowpmopm2Mesrchannel72Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel72 table |
| 1.3.6.1.4.1.20044.64.3.2.158.1.1 | Columnpmopm2Mesrchannel72Index | read-only | current | Index definition for the pmopm2Mesrchannel72 table |
| 1.3.6.1.4.1.20044.64.3.2.158.1.2 | Columnpmopm2Mesrchannel72Portn | read-only | current | Channel72 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.160 | Tablepmopm2Mesrchannel73Table | not-accessible | current | List of pmopm2Mesrchannel73 Article |
| 1.3.6.1.4.1.20044.64.3.2.160.1 | Rowpmopm2Mesrchannel73Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel73 table |
| 1.3.6.1.4.1.20044.64.3.2.160.1.1 | Columnpmopm2Mesrchannel73Index | read-only | current | Index definition for the pmopm2Mesrchannel73 table |
| 1.3.6.1.4.1.20044.64.3.2.160.1.2 | Columnpmopm2Mesrchannel73Portn | read-only | current | Channel73 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.162 | Tablepmopm2Mesrchannel74Table | not-accessible | current | List of pmopm2Mesrchannel74 Article |
| 1.3.6.1.4.1.20044.64.3.2.162.1 | Rowpmopm2Mesrchannel74Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel74 table |
| 1.3.6.1.4.1.20044.64.3.2.162.1.1 | Columnpmopm2Mesrchannel74Index | read-only | current | Index definition for the pmopm2Mesrchannel74 table |
| 1.3.6.1.4.1.20044.64.3.2.162.1.2 | Columnpmopm2Mesrchannel74Portn | read-only | current | Channel74 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.164 | Tablepmopm2Mesrchannel75Table | not-accessible | current | List of pmopm2Mesrchannel75 Article |
| 1.3.6.1.4.1.20044.64.3.2.164.1 | Rowpmopm2Mesrchannel75Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel75 table |
| 1.3.6.1.4.1.20044.64.3.2.164.1.1 | Columnpmopm2Mesrchannel75Index | read-only | current | Index definition for the pmopm2Mesrchannel75 table |
| 1.3.6.1.4.1.20044.64.3.2.164.1.2 | Columnpmopm2Mesrchannel75Portn | read-only | current | Channel75 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.166 | Tablepmopm2Mesrchannel76Table | not-accessible | current | List of pmopm2Mesrchannel76 Article |
| 1.3.6.1.4.1.20044.64.3.2.166.1 | Rowpmopm2Mesrchannel76Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel76 table |
| 1.3.6.1.4.1.20044.64.3.2.166.1.1 | Columnpmopm2Mesrchannel76Index | read-only | current | Index definition for the pmopm2Mesrchannel76 table |
| 1.3.6.1.4.1.20044.64.3.2.166.1.2 | Columnpmopm2Mesrchannel76Portn | read-only | current | Channel76 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.168 | Tablepmopm2Mesrchannel77Table | not-accessible | current | List of pmopm2Mesrchannel77 Article |
| 1.3.6.1.4.1.20044.64.3.2.168.1 | Rowpmopm2Mesrchannel77Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel77 table |
| 1.3.6.1.4.1.20044.64.3.2.168.1.1 | Columnpmopm2Mesrchannel77Index | read-only | current | Index definition for the pmopm2Mesrchannel77 table |
| 1.3.6.1.4.1.20044.64.3.2.168.1.2 | Columnpmopm2Mesrchannel77Portn | read-only | current | Channel77 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.170 | Tablepmopm2Mesrchannel78Table | not-accessible | current | List of pmopm2Mesrchannel78 Article |
| 1.3.6.1.4.1.20044.64.3.2.170.1 | Rowpmopm2Mesrchannel78Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel78 table |
| 1.3.6.1.4.1.20044.64.3.2.170.1.1 | Columnpmopm2Mesrchannel78Index | read-only | current | Index definition for the pmopm2Mesrchannel78 table |
| 1.3.6.1.4.1.20044.64.3.2.170.1.2 | Columnpmopm2Mesrchannel78Portn | read-only | current | Channel78 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.172 | Tablepmopm2Mesrchannel79Table | not-accessible | current | List of pmopm2Mesrchannel79 Article |
| 1.3.6.1.4.1.20044.64.3.2.172.1 | Rowpmopm2Mesrchannel79Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel79 table |
| 1.3.6.1.4.1.20044.64.3.2.172.1.1 | Columnpmopm2Mesrchannel79Index | read-only | current | Index definition for the pmopm2Mesrchannel79 table |
| 1.3.6.1.4.1.20044.64.3.2.172.1.2 | Columnpmopm2Mesrchannel79Portn | read-only | current | Channel79 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.174 | Tablepmopm2Mesrchannel80Table | not-accessible | current | List of pmopm2Mesrchannel80 Article |
| 1.3.6.1.4.1.20044.64.3.2.174.1 | Rowpmopm2Mesrchannel80Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel80 table |
| 1.3.6.1.4.1.20044.64.3.2.174.1.1 | Columnpmopm2Mesrchannel80Index | read-only | current | Index definition for the pmopm2Mesrchannel80 table |
| 1.3.6.1.4.1.20044.64.3.2.174.1.2 | Columnpmopm2Mesrchannel80Portn | read-only | current | Channel80 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.176 | Tablepmopm2Mesrchannel81Table | not-accessible | current | List of pmopm2Mesrchannel81 Article |
| 1.3.6.1.4.1.20044.64.3.2.176.1 | Rowpmopm2Mesrchannel81Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel81 table |
| 1.3.6.1.4.1.20044.64.3.2.176.1.1 | Columnpmopm2Mesrchannel81Index | read-only | current | Index definition for the pmopm2Mesrchannel81 table |
| 1.3.6.1.4.1.20044.64.3.2.176.1.2 | Columnpmopm2Mesrchannel81Portn | read-only | current | Channel81 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.178 | Tablepmopm2Mesrchannel82Table | not-accessible | current | List of pmopm2Mesrchannel82 Article |
| 1.3.6.1.4.1.20044.64.3.2.178.1 | Rowpmopm2Mesrchannel82Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel82 table |
| 1.3.6.1.4.1.20044.64.3.2.178.1.1 | Columnpmopm2Mesrchannel82Index | read-only | current | Index definition for the pmopm2Mesrchannel82 table |
| 1.3.6.1.4.1.20044.64.3.2.178.1.2 | Columnpmopm2Mesrchannel82Portn | read-only | current | Channel82 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.180 | Tablepmopm2Mesrchannel83Table | not-accessible | current | List of pmopm2Mesrchannel83 Article |
| 1.3.6.1.4.1.20044.64.3.2.180.1 | Rowpmopm2Mesrchannel83Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel83 table |
| 1.3.6.1.4.1.20044.64.3.2.180.1.1 | Columnpmopm2Mesrchannel83Index | read-only | current | Index definition for the pmopm2Mesrchannel83 table |
| 1.3.6.1.4.1.20044.64.3.2.180.1.2 | Columnpmopm2Mesrchannel83Portn | read-only | current | Channel83 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.182 | Tablepmopm2Mesrchannel84Table | not-accessible | current | List of pmopm2Mesrchannel84 Article |
| 1.3.6.1.4.1.20044.64.3.2.182.1 | Rowpmopm2Mesrchannel84Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel84 table |
| 1.3.6.1.4.1.20044.64.3.2.182.1.1 | Columnpmopm2Mesrchannel84Index | read-only | current | Index definition for the pmopm2Mesrchannel84 table |
| 1.3.6.1.4.1.20044.64.3.2.182.1.2 | Columnpmopm2Mesrchannel84Portn | read-only | current | Channel84 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.184 | Tablepmopm2Mesrchannel85Table | not-accessible | current | List of pmopm2Mesrchannel85 Article |
| 1.3.6.1.4.1.20044.64.3.2.184.1 | Rowpmopm2Mesrchannel85Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel85 table |
| 1.3.6.1.4.1.20044.64.3.2.184.1.1 | Columnpmopm2Mesrchannel85Index | read-only | current | Index definition for the pmopm2Mesrchannel85 table |
| 1.3.6.1.4.1.20044.64.3.2.184.1.2 | Columnpmopm2Mesrchannel85Portn | read-only | current | Channel85 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.186 | Tablepmopm2Mesrchannel86Table | not-accessible | current | List of pmopm2Mesrchannel86 Article |
| 1.3.6.1.4.1.20044.64.3.2.186.1 | Rowpmopm2Mesrchannel86Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel86 table |
| 1.3.6.1.4.1.20044.64.3.2.186.1.1 | Columnpmopm2Mesrchannel86Index | read-only | current | Index definition for the pmopm2Mesrchannel86 table |
| 1.3.6.1.4.1.20044.64.3.2.186.1.2 | Columnpmopm2Mesrchannel86Portn | read-only | current | Channel86 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.188 | Tablepmopm2Mesrchannel87Table | not-accessible | current | List of pmopm2Mesrchannel87 Article |
| 1.3.6.1.4.1.20044.64.3.2.188.1 | Rowpmopm2Mesrchannel87Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel87 table |
| 1.3.6.1.4.1.20044.64.3.2.188.1.1 | Columnpmopm2Mesrchannel87Index | read-only | current | Index definition for the pmopm2Mesrchannel87 table |
| 1.3.6.1.4.1.20044.64.3.2.188.1.2 | Columnpmopm2Mesrchannel87Portn | read-only | current | Channel87 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.190 | Tablepmopm2Mesrchannel88Table | not-accessible | current | List of pmopm2Mesrchannel88 Article |
| 1.3.6.1.4.1.20044.64.3.2.190.1 | Rowpmopm2Mesrchannel88Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel88 table |
| 1.3.6.1.4.1.20044.64.3.2.190.1.1 | Columnpmopm2Mesrchannel88Index | read-only | current | Index definition for the pmopm2Mesrchannel88 table |
| 1.3.6.1.4.1.20044.64.3.2.190.1.2 | Columnpmopm2Mesrchannel88Portn | read-only | current | Channel88 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.192 | Tablepmopm2Mesrchannel89Table | not-accessible | current | List of pmopm2Mesrchannel89 Article |
| 1.3.6.1.4.1.20044.64.3.2.192.1 | Rowpmopm2Mesrchannel89Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel89 table |
| 1.3.6.1.4.1.20044.64.3.2.192.1.1 | Columnpmopm2Mesrchannel89Index | read-only | current | Index definition for the pmopm2Mesrchannel89 table |
| 1.3.6.1.4.1.20044.64.3.2.192.1.2 | Columnpmopm2Mesrchannel89Portn | read-only | current | Channel89 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.194 | Tablepmopm2Mesrchannel90Table | not-accessible | current | List of pmopm2Mesrchannel90 Article |
| 1.3.6.1.4.1.20044.64.3.2.194.1 | Rowpmopm2Mesrchannel90Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel90 table |
| 1.3.6.1.4.1.20044.64.3.2.194.1.1 | Columnpmopm2Mesrchannel90Index | read-only | current | Index definition for the pmopm2Mesrchannel90 table |
| 1.3.6.1.4.1.20044.64.3.2.194.1.2 | Columnpmopm2Mesrchannel90Portn | read-only | current | Channel90 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.196 | Tablepmopm2Mesrchannel91Table | not-accessible | current | List of pmopm2Mesrchannel91 Article |
| 1.3.6.1.4.1.20044.64.3.2.196.1 | Rowpmopm2Mesrchannel91Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel91 table |
| 1.3.6.1.4.1.20044.64.3.2.196.1.1 | Columnpmopm2Mesrchannel91Index | read-only | current | Index definition for the pmopm2Mesrchannel91 table |
| 1.3.6.1.4.1.20044.64.3.2.196.1.2 | Columnpmopm2Mesrchannel91Portn | read-only | current | Channel91 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.198 | Tablepmopm2Mesrchannel92Table | not-accessible | current | List of pmopm2Mesrchannel92 Article |
| 1.3.6.1.4.1.20044.64.3.2.198.1 | Rowpmopm2Mesrchannel92Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel92 table |
| 1.3.6.1.4.1.20044.64.3.2.198.1.1 | Columnpmopm2Mesrchannel92Index | read-only | current | Index definition for the pmopm2Mesrchannel92 table |
| 1.3.6.1.4.1.20044.64.3.2.198.1.2 | Columnpmopm2Mesrchannel92Portn | read-only | current | Channel92 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.200 | Tablepmopm2Mesrchannel93Table | not-accessible | current | List of pmopm2Mesrchannel93 Article |
| 1.3.6.1.4.1.20044.64.3.2.200.1 | Rowpmopm2Mesrchannel93Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel93 table |
| 1.3.6.1.4.1.20044.64.3.2.200.1.1 | Columnpmopm2Mesrchannel93Index | read-only | current | Index definition for the pmopm2Mesrchannel93 table |
| 1.3.6.1.4.1.20044.64.3.2.200.1.2 | Columnpmopm2Mesrchannel93Portn | read-only | current | Channel93 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.202 | Tablepmopm2Mesrchannel94Table | not-accessible | current | List of pmopm2Mesrchannel94 Article |
| 1.3.6.1.4.1.20044.64.3.2.202.1 | Rowpmopm2Mesrchannel94Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel94 table |
| 1.3.6.1.4.1.20044.64.3.2.202.1.1 | Columnpmopm2Mesrchannel94Index | read-only | current | Index definition for the pmopm2Mesrchannel94 table |
| 1.3.6.1.4.1.20044.64.3.2.202.1.2 | Columnpmopm2Mesrchannel94Portn | read-only | current | Channel94 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.204 | Tablepmopm2Mesrchannel95Table | not-accessible | current | List of pmopm2Mesrchannel95 Article |
| 1.3.6.1.4.1.20044.64.3.2.204.1 | Rowpmopm2Mesrchannel95Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel95 table |
| 1.3.6.1.4.1.20044.64.3.2.204.1.1 | Columnpmopm2Mesrchannel95Index | read-only | current | Index definition for the pmopm2Mesrchannel95 table |
| 1.3.6.1.4.1.20044.64.3.2.204.1.2 | Columnpmopm2Mesrchannel95Portn | read-only | current | Channel95 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.206 | Tablepmopm2Mesrchannel96Table | not-accessible | current | List of pmopm2Mesrchannel96 Article |
| 1.3.6.1.4.1.20044.64.3.2.206.1 | Rowpmopm2Mesrchannel96Entry | not-accessible | current | Row definition for the pmopm2Mesrchannel96 table |
| 1.3.6.1.4.1.20044.64.3.2.206.1.1 | Columnpmopm2Mesrchannel96Index | read-only | current | Index definition for the pmopm2Mesrchannel96 table |
| 1.3.6.1.4.1.20044.64.3.2.206.1.2 | Columnpmopm2Mesrchannel96Portn | read-only | current | Channel96 Power :This OID indicates the channel power (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the channel power |
| 1.3.6.1.4.1.20044.64.3.2.208 | Tablepmopm2MesrportInputPwrTable | not-accessible | current | List of pmopm2MesrportInputPwr Article |
| 1.3.6.1.4.1.20044.64.3.2.208.1 | Rowpmopm2MesrportInputPwrEntry | not-accessible | current | Row definition for the pmopm2MesrportInputPwr table |
| 1.3.6.1.4.1.20044.64.3.2.208.1.1 | Columnpmopm2MesrportInputPwrIndex | read-only | current | Index definition for the pmopm2MesrportInputPwr table |
| 1.3.6.1.4.1.20044.64.3.2.208.1.2 | Columnpmopm2MesrportInputPwrPortn | read-only | current | OPM Port Input Power :This OID indicates the total input power on the OPM port (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates the total i… |
| 1.3.6.1.4.1.20044.64.3.2.210 | Tablepmopm2MesrchannelMaxPwrTable | not-accessible | current | List of pmopm2MesrchannelMaxPwr Article |
| 1.3.6.1.4.1.20044.64.3.2.210.1 | Rowpmopm2MesrchannelMaxPwrEntry | not-accessible | current | Row definition for the pmopm2MesrchannelMaxPwr table |
| 1.3.6.1.4.1.20044.64.3.2.210.1.1 | Columnpmopm2MesrchannelMaxPwrIndex | read-only | current | Index definition for the pmopm2MesrchannelMaxPwr table |
| 1.3.6.1.4.1.20044.64.3.2.210.1.2 | Columnpmopm2MesrchannelMaxPwrPortn | read-only | current | Channel Maximum Power :This OID indicates the maximum channel power on the OPM input port (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates … |
| 1.3.6.1.4.1.20044.64.3.2.212 | Tablepmopm2MesrchannelMinPwrTable | not-accessible | current | List of pmopm2MesrchannelMinPwr Article |
| 1.3.6.1.4.1.20044.64.3.2.212.1 | Rowpmopm2MesrchannelMinPwrEntry | not-accessible | current | Row definition for the pmopm2MesrchannelMinPwr table |
| 1.3.6.1.4.1.20044.64.3.2.212.1.1 | Columnpmopm2MesrchannelMinPwrIndex | read-only | current | Index definition for the pmopm2MesrchannelMinPwr table |
| 1.3.6.1.4.1.20044.64.3.2.212.1.2 | Columnpmopm2MesrchannelMinPwrPortn | read-only | current | Channel Minimum Power :This OID indicates the minimum channel power on the OPM input port (Power =Q8(Number format)) (Unit = dBm)<Help> This measure indicates … |
| 1.3.6.1.4.1.20044.64.3.3 | Nodepmopm2MesrLine | |||
| 1.3.6.1.4.1.20044.64.6 | Nodepmopm2controlsWrite | |||
| 1.3.6.1.4.1.20044.64.6.1 | Nodepmopm2CtrlOther | |||
| 1.3.6.1.4.1.20044.64.6.1.1 | Nodepmopm2CtrlconfMgnt1 | |||
| 1.3.6.1.4.1.20044.64.6.1.1.1 | Scalarpmopm2CtrlConf1Load1 | read-write | current | Load Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM. |
| 1.3.6.1.4.1.20044.64.6.1.1.2 | Scalarpmopm2CtrlConf2Load1 | read-write | current | Load Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM. |
| 1.3.6.1.4.1.20044.64.6.1.1.10 | Scalarpmopm2CtrlConf2Flash1 | read-write | current | Write Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura… |
| 1.3.6.1.4.1.20044.64.6.1.1.14 | Scalarpmopm2CtrlConf2Clear1 | read-write | current | Clear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o… |
| 1.3.6.1.4.1.20044.64.6.1.4 | Nodepmopm2Ctrlsynth4 | |||
| 1.3.6.1.4.1.20044.64.6.1.4.1 | Scalarpmopm2CtrlCorrelatOn | read-write | current | Enable Alarm Correlation :This OID enables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.64.6.1.4.2 | Scalarpmopm2CtrlCorrelatOff | read-write | current | Disable Alarm Correlation :This OID disables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.64.6.1.5 | Nodepmopm2CtrlswMgnt | |||
| 1.3.6.1.4.1.20044.64.6.1.5.2 | Scalarpmopm2CtrlColdReset | read-write | current | PM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> … |
| 1.3.6.1.4.1.20044.64.6.1.5.3 | Scalarpmopm2CtrlWarmReset | read-write | current | PM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th… |
| 1.3.6.1.4.1.20044.64.6.1.5.5 | Scalarpmopm2CtrlLoadSwBank1 | read-write | current | Set Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW… |
| 1.3.6.1.4.1.20044.64.6.1.5.6 | Scalarpmopm2CtrlLoadSwBank2 | read-write | current | Set Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S… |
| 1.3.6.1.4.1.20044.64.6.1.6 | Nodepmopm2CtrlgwMgnt | |||
| 1.3.6.1.4.1.20044.64.6.1.6.1 | Scalarpmopm2CtrlCurrentGwReset | read-write | current | Active Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting. |
| 1.3.6.1.4.1.20044.64.6.1.6.5 | Scalarpmopm2CtrlLoadGwBank1 | read-write | current | Set Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.64.6.1.6.6 | Scalarpmopm2CtrlLoadGwBank2 | read-write | current | Set Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.64.6.1.6.7 | Scalarpmopm2CtrlLoadGwBank3 | read-write | current | Set Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.64.6.1.6.8 | Scalarpmopm2CtrlLoadGwBank4 | read-write | current | Set Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.64.6.1.192 | Nodepmopm2CtrlledTest | |||
| 1.3.6.1.4.1.20044.64.6.1.192.1 | Scalarpmopm2CtrlGreenLed | read-write | current | Green Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green |
| 1.3.6.1.4.1.20044.64.6.1.192.2 | Scalarpmopm2CtrlRedLed | read-write | current | Red Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red |
| 1.3.6.1.4.1.20044.64.6.1.192.3 | Scalarpmopm2CtrlLedOff | read-write | current | Leds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF |
| 1.3.6.1.4.1.20044.64.6.2 | Nodepmopm2CtrlClient | |||
| 1.3.6.1.4.1.20044.64.6.2.16 | Tablepmopm2CtrlcalibrationTable | not-accessible | current | List of pmopm2Ctrlcalibration Article |
| 1.3.6.1.4.1.20044.64.6.2.16.1 | Rowpmopm2CtrlcalibrationEntry | not-accessible | current | Row definition for the pmopm2Ctrlcalibration table |
| 1.3.6.1.4.1.20044.64.6.2.16.1.1 | Columnpmopm2CtrlcalibrationIndex | read-only | current | Index definition for the pmopm2Ctrlcalibration table |
| 1.3.6.1.4.1.20044.64.6.2.16.1.2 | Columnpmopm2CtrlcalibrationPortn | read-write | current | Port Calibration :This OID initiates the OPM input calibration to define automatically the OPM offset value. <Help> This parameter initiates the OPM input cali… |
| 1.3.6.1.4.1.20044.64.6.2.17 | Tablepmopm2CtrlspectrumAutodiscoveryTable | not-accessible | current | List of pmopm2CtrlspectrumAutodiscovery Article |
| 1.3.6.1.4.1.20044.64.6.2.17.1 | Rowpmopm2CtrlspectrumAutodiscoveryEntry | not-accessible | current | Row definition for the pmopm2CtrlspectrumAutodiscovery table |
| 1.3.6.1.4.1.20044.64.6.2.17.1.1 | Columnpmopm2CtrlspectrumAutodiscoveryIndex | read-only | current | Index definition for the pmopm2CtrlspectrumAutodiscovery table |
| 1.3.6.1.4.1.20044.64.6.2.17.1.2 | Columnpmopm2CtrlspectrumAutodiscoveryPortn | read-write | current | Spectrum Auto Discovery :This OID initiates the OPM scanning to define automatically the channels to monitor <Help> This parameter initiates the automatic conf… |
| 1.3.6.1.4.1.20044.64.6.2.18 | Tablepmopm2CtrlthresholdsAutoconfigTable | not-accessible | current | List of pmopm2CtrlthresholdsAutoconfig Article |
| 1.3.6.1.4.1.20044.64.6.2.18.1 | Rowpmopm2CtrlthresholdsAutoconfigEntry | not-accessible | current | Row definition for the pmopm2CtrlthresholdsAutoconfig table |
| 1.3.6.1.4.1.20044.64.6.2.18.1.1 | Columnpmopm2CtrlthresholdsAutoconfigIndex | read-only | current | Index definition for the pmopm2CtrlthresholdsAutoconfig table |
| 1.3.6.1.4.1.20044.64.6.2.18.1.2 | Columnpmopm2CtrlthresholdsAutoconfigPortn | read-write | current | Thresholds Auto Configuration :This OID initiates the automatic configuration of the thresholds (for each channel) using the user-defined delta.<Help> This par… |
| 1.3.6.1.4.1.20044.64.6.2.32 | Tablepmopm2CtrlpowerLossDeltaTable | not-accessible | current | List of pmopm2CtrlpowerLossDelta Article |
| 1.3.6.1.4.1.20044.64.6.2.32.1 | Rowpmopm2CtrlpowerLossDeltaEntry | not-accessible | current | Row definition for the pmopm2CtrlpowerLossDelta table |
| 1.3.6.1.4.1.20044.64.6.2.32.1.1 | Columnpmopm2CtrlpowerLossDeltaIndex | read-only | current | Index definition for the pmopm2CtrlpowerLossDelta table |
| 1.3.6.1.4.1.20044.64.6.2.32.1.2 | Columnpmopm2CtrlpowerLossDeltaPortn | read-write | current | Power Loss Delta :This OID defines the delta to use to define the channel absence threshold (AV=InvQ8(Delta)) (Unit = dB)<Help> This parameter defines the delt… |
| 1.3.6.1.4.1.20044.64.6.2.40 | Tablepmopm2CtrlpowerHighDeltaTable | not-accessible | current | List of pmopm2CtrlpowerHighDelta Article |
| 1.3.6.1.4.1.20044.64.6.2.40.1 | Rowpmopm2CtrlpowerHighDeltaEntry | not-accessible | current | Row definition for the pmopm2CtrlpowerHighDelta table |
| 1.3.6.1.4.1.20044.64.6.2.40.1.1 | Columnpmopm2CtrlpowerHighDeltaIndex | read-only | current | Index definition for the pmopm2CtrlpowerHighDelta table |
| 1.3.6.1.4.1.20044.64.6.2.40.1.2 | Columnpmopm2CtrlpowerHighDeltaPortn | read-write | current | Power High Delta :This OID defines the delta to use to define the channel absence threshold (AV=InvQ8(Delta)) (Unit = dB)<Help> This parameter defines the delt… |
| 1.3.6.1.4.1.20044.64.6.2.48 | Tablepmopm2CtrlpowerLowDeltaTable | not-accessible | current | List of pmopm2CtrlpowerLowDelta Article |
| 1.3.6.1.4.1.20044.64.6.2.48.1 | Rowpmopm2CtrlpowerLowDeltaEntry | not-accessible | current | Row definition for the pmopm2CtrlpowerLowDelta table |
| 1.3.6.1.4.1.20044.64.6.2.48.1.1 | Columnpmopm2CtrlpowerLowDeltaIndex | read-only | current | Index definition for the pmopm2CtrlpowerLowDelta table |
| 1.3.6.1.4.1.20044.64.6.2.48.1.2 | Columnpmopm2CtrlpowerLowDeltaPortn | read-write | current | Power Low Delta :This OID defines the delta to use to define the channel absence threshold (AV=InvQ8(Delta)) (Unit = dB)<Help> This parameter defines the delta… |
| 1.3.6.1.4.1.20044.64.6.2.64 | Tablepmopm2CtrlinputPowerRefTable | not-accessible | current | List of pmopm2CtrlinputPowerRef Article |
| 1.3.6.1.4.1.20044.64.6.2.64.1 | Rowpmopm2CtrlinputPowerRefEntry | not-accessible | current | Row definition for the pmopm2CtrlinputPowerRef table |
| 1.3.6.1.4.1.20044.64.6.2.64.1.1 | Columnpmopm2CtrlinputPowerRefIndex | read-only | current | Index definition for the pmopm2CtrlinputPowerRef table |
| 1.3.6.1.4.1.20044.64.6.2.64.1.2 | Columnpmopm2CtrlinputPowerRefPortn | read-write | current | Input Power Reference :This OID defines the input power reference used to calibrate the OPM input power. (AV=InvQ8(Power)) (Unit = dBm)<Help> This parameter de… |
| 1.3.6.1.4.1.20044.64.6.3 | Nodepmopm2CtrlLine | |||
| 1.3.6.1.4.1.20044.64.7 | Nodepmopm2ri | |||
| 1.3.6.1.4.1.20044.64.7.1 | Nodepmopm2riTable | |||
| 1.3.6.1.4.1.20044.64.7.1.1 | Tablepmopm2RinvSfpTable | not-accessible | current | List of the SFPs on the selected module |
| 1.3.6.1.4.1.20044.64.7.1.1.1 | Rowpmopm2RinvSfpEntry | not-accessible | current | Row definition for the SFP table |
| 1.3.6.1.4.1.20044.64.7.1.1.1.1 | Columnpmopm2RinvSfpIndex | read-only | current | Index for SFP table |
| 1.3.6.1.4.1.20044.64.7.1.1.1.2 | Columnpmopm2Rinvsfp | read-only | current | Inventory for the SFP: This OID contains the inventory for the SFP |
| 1.3.6.1.4.1.20044.64.7.1.2 | Tablepmopm2RinvLineTable | not-accessible | current | List of the XFPs on the selected module |
| 1.3.6.1.4.1.20044.64.7.1.2.1 | Rowpmopm2RinvLineEntry | not-accessible | current | Row definition for the XFP table |
| 1.3.6.1.4.1.20044.64.7.1.2.1.1 | Columnpmopm2RinvLineIndex | read-only | current | Index for XFP table |
| 1.3.6.1.4.1.20044.64.7.1.2.1.2 | Columnpmopm2RinvxfpLine | read-only | current | Inventory for the XFP: This OID contains the inventory for the XFP |
| 1.3.6.1.4.1.20044.64.7.2 | Scalarpmopm2RinvReloadInventory | read-write | current | Reload the inventory: This OID triggers an inventory reload. |
| 1.3.6.1.4.1.20044.64.7.3 | Scalarpmopm2RinvHwPlatform | read-only | current | HW platform description: This OID contains the description of the Hardware platform. |
| 1.3.6.1.4.1.20044.64.7.4 | Scalarpmopm2RinvModulePlatform | read-only | current | Module platform description: This OID contains the description of the Module. |
| 1.3.6.1.4.1.20044.64.7.5 | Scalarpmopm2RinvSwPlatform | read-only | current | SW platform description: This OID contains the description of the Software platform. |
| 1.3.6.1.4.1.20044.64.7.6 | Scalarpmopm2RinvGwPlatform | read-only | current | GW platform desciption: This OID contains the description of the Gateware platform. |
| 1.3.6.1.4.1.20044.64.8 | Nodepmopm2download | |||
| 1.3.6.1.4.1.20044.64.8.1 | Nodepmopm2DwlOther | |||
| 1.3.6.1.4.1.20044.64.8.1.0 | Nodepmopm2DwlrestartProcess | |||
| 1.3.6.1.4.1.20044.64.8.1.0.1 | Scalarpmopm2DwlWarmRestartProcessed | read-only | current | Warm Restart :This OID indicates that the module last restart was a Warm RESTART |
| 1.3.6.1.4.1.20044.64.8.1.0.2 | Scalarpmopm2DwlColdRestartProcessed | read-only | current | Cold Restart :This OID indicates that the module last restart was a Cold RESTART |
| 1.3.6.1.4.1.20044.64.8.1.1 | Nodepmopm2DwlswBanksUsed | |||
| 1.3.6.1.4.1.20044.64.8.1.1.1 | Scalarpmopm2DwlSwBank1Used | read-only | current | SW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.64.8.1.1.2 | Scalarpmopm2DwlSwBank2Used | read-only | current | SW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby |
| 1.3.6.1.4.1.20044.64.8.1.1.5 | Scalarpmopm2DwlSwBank1Notempty | read-only | current | SW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package |
| 1.3.6.1.4.1.20044.64.8.1.1.6 | Scalarpmopm2DwlSwBank2Notempty | read-only | current | SW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package |
| 1.3.6.1.4.1.20044.64.8.1.2 | Nodepmopm2DwlgwBanksUsed | |||
| 1.3.6.1.4.1.20044.64.8.1.2.1 | Scalarpmopm2DwlGwBank1Used | read-only | current | GW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.64.8.1.2.2 | Scalarpmopm2DwlGwBank2Used | read-only | current | GW bank 2 active :This OID indicates the module is working on GW bank 2 |
| 1.3.6.1.4.1.20044.64.8.1.2.3 | Scalarpmopm2DwlGwBank3Used | read-only | current | GW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby |
| 1.3.6.1.4.1.20044.64.8.1.2.4 | Scalarpmopm2DwlGwBank4Used | read-only | current | GW bank 4 active :This OID indicates the module is working on GW bank 4 |
| 1.3.6.1.4.1.20044.64.8.1.2.5 | Scalarpmopm2DwlGwBank1Notempty | read-only | current | GW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package |
| 1.3.6.1.4.1.20044.64.8.1.2.6 | Scalarpmopm2DwlGwBank2Notempty | read-only | current | GW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2 |
| 1.3.6.1.4.1.20044.64.8.1.2.7 | Scalarpmopm2DwlGwBank3Notempty | read-only | current | GW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package |
| 1.3.6.1.4.1.20044.64.8.1.2.8 | Scalarpmopm2DwlGwBank4Notempty | read-only | current | GW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4 |
| 1.3.6.1.4.1.20044.64.8.2 | Nodepmopm2DwlClient | |||
| 1.3.6.1.4.1.20044.64.8.3 | Nodepmopm2DwlLine | |||
| 1.3.6.1.4.1.20044.64.9 | Nodepmopm2Config | |||
| 1.3.6.1.4.1.20044.64.9.1 | Nodepmopm2CfgLsd | |||
| 1.3.6.1.4.1.20044.64.9.1.1 | Nodepmopm2tableclientcaiscsf | |||
| 1.3.6.1.4.1.20044.64.9.2 | Nodepmopm2CfgStartup | |||
| 1.3.6.1.4.1.20044.64.9.2.1 | Nodepmopm2tableother | |||
| 1.3.6.1.4.1.20044.64.9.2.1.2 | Scalarpmopm2CfgcomponentType | read-only | current | Component parameters :This OID defines the component parameters |
| 1.3.6.1.4.1.20044.64.9.2.1.3 | Scalarpmopm2Cfgmiscellaneous | read-only | current | Miscellaneous default settings :This OID defines the miscellaneous parameters |
| 1.3.6.1.4.1.20044.64.9.2.1.4 | Scalarpmopm2CfgfirstChannel | read-only | current | Number of the first channel of the component :This OID defines the first channel number of the PMOPM |
| 1.3.6.1.4.1.20044.64.9.2.1.5 | Scalarpmopm2CfglastChannel | read-only | current | Number of the last channel of the component :This OID defines the last channel number of the PMOPM |
| 1.3.6.1.4.1.20044.64.9.2.1.6 | Scalarpmopm2Cfggrid | read-only | current | Grid value of the component :This OID defines the grid of the PMOPM |
| 1.3.6.1.4.1.20044.64.9.2.2 | Tablepmopm2CfgClientStartupOosTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.64.9.2.2.1 | Rowpmopm2CfgClientStartupOosEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.64.9.2.2.1.1 | Columnpmopm2CfgClientStartupOosIndex | read-only | current | Index definition for the clientStartupOos table |
| 1.3.6.1.4.1.20044.64.9.2.2.1.3 | Columnpmopm2CfgSpectrumOosPortn | read-write | current | Default Settings on Spectrum OOS :This OID sets the OPM input port out of service |
| 1.3.6.1.4.1.20044.64.9.2.2.1.4 | Columnpmopm2CfgSpectrumOffsetPortn | read-write | current | Default Settings on Spectrum Offset :This OID defines a negative offset for the OPM input port |
| 1.3.6.1.4.1.20044.64.9.2.2.1.5 | Columnpmopm2CfgCh1Ch16OosPortn | read-write | current | Default Settings on Channel OOS :This OID sets the channel out of service |
| 1.3.6.1.4.1.20044.64.9.2.2.1.6 | Columnpmopm2CfgCh17Ch32OosPortn | read-write | current | Default Settings on Channel OOS :This OID sets the channel out of service |
| 1.3.6.1.4.1.20044.64.9.2.2.1.7 | Columnpmopm2CfgCh33Ch48OosPortn | read-write | current | Default Settings on Channel OOS :This OID sets the channel out of service |
| 1.3.6.1.4.1.20044.64.9.2.2.1.8 | Columnpmopm2CfgCh49Ch64OosPortn | read-write | current | Default Settings on Channel OOS :This OID sets the channel out of service |
| 1.3.6.1.4.1.20044.64.9.2.2.1.9 | Columnpmopm2CfgCh65Ch80OosPortn | read-write | current | Default Settings on Channel OOS :This OID sets the channel out of service |
| 1.3.6.1.4.1.20044.64.9.2.2.1.10 | Columnpmopm2CfgCh81Ch96OosPortn | read-write | current | Default Settings on Channel OOS :This OID sets the channel out of service |
| 1.3.6.1.4.1.20044.64.9.2.3 | Tablepmopm2CfgClientStartupBalanceTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.64.9.2.3.1 | Rowpmopm2CfgClientStartupBalanceEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.64.9.2.3.1.1 | Columnpmopm2CfgClientStartupBalanceIndex | read-only | current | Index definition for the clientStartupBalance table |
| 1.3.6.1.4.1.20044.64.9.2.3.1.3 | Columnpmopm2CfgCh1Ch16BalancePortn | read-write | current | Default Settings on Balance :This OID is used by the Ekinops auto turn up application to tag the channel as balanced |
| 1.3.6.1.4.1.20044.64.9.2.3.1.4 | Columnpmopm2CfgCh17Ch32BalancePortn | read-write | current | Default Settings on Balance :This OID is used by the Ekinops auto turn up application to tag the channel as balanced |
| 1.3.6.1.4.1.20044.64.9.2.3.1.5 | Columnpmopm2CfgCh33Ch48BalancePortn | read-write | current | Default Settings on Balance :This OID is used by the Ekinops auto turn up application to tag the channel as balanced |
| 1.3.6.1.4.1.20044.64.9.2.3.1.6 | Columnpmopm2CfgCh49Ch64BalancePortn | read-write | current | Default Settings on Balance :This OID is used by the Ekinops auto turn up application to tag the channel as balanced |
| 1.3.6.1.4.1.20044.64.9.2.3.1.7 | Columnpmopm2CfgCh65Ch80BalancePortn | read-write | current | Default Settings on Balance :This OID is used by the Ekinops auto turn up application to tag the channel as balanced |
| 1.3.6.1.4.1.20044.64.9.2.3.1.8 | Columnpmopm2CfgCh81Ch96BalancePortn | read-write | current | Default Settings on Balance :This OID is used by the Ekinops auto turn up application to tag the channel as balanced |
| 1.3.6.1.4.1.20044.64.9.2.4 | Tablepmopm2CfgClientStartupAbsthreshTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.64.9.2.4.1 | Rowpmopm2CfgClientStartupAbsthreshEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.64.9.2.4.1.1 | Columnpmopm2CfgClientStartupAbsthreshIndex | read-only | current | Index definition for the clientStartupAbsthresh table |
| 1.3.6.1.4.1.20044.64.9.2.4.1.3 | Columnpmopm2CfgChannel1AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.4 | Columnpmopm2CfgChannel2AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.5 | Columnpmopm2CfgChannel3AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.6 | Columnpmopm2CfgChannel4AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.7 | Columnpmopm2CfgChannel5AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.8 | Columnpmopm2CfgChannel6AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.9 | Columnpmopm2CfgChannel7AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.10 | Columnpmopm2CfgChannel8AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.11 | Columnpmopm2CfgChannel9AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.12 | Columnpmopm2CfgChannel10AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.13 | Columnpmopm2CfgChannel11AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.14 | Columnpmopm2CfgChannel12AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.15 | Columnpmopm2CfgChannel13AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.16 | Columnpmopm2CfgChannel14AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.17 | Columnpmopm2CfgChannel15AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.18 | Columnpmopm2CfgChannel16AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.19 | Columnpmopm2CfgChannel17AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.20 | Columnpmopm2CfgChannel18AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.21 | Columnpmopm2CfgChannel19AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.22 | Columnpmopm2CfgChannel20AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.23 | Columnpmopm2CfgChannel21AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.24 | Columnpmopm2CfgChannel22AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.25 | Columnpmopm2CfgChannel23AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.26 | Columnpmopm2CfgChannel24AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.27 | Columnpmopm2CfgChannel25AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.28 | Columnpmopm2CfgChannel26AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.29 | Columnpmopm2CfgChannel27AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.30 | Columnpmopm2CfgChannel28AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.31 | Columnpmopm2CfgChannel29AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.32 | Columnpmopm2CfgChannel30AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.33 | Columnpmopm2CfgChannel31AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.34 | Columnpmopm2CfgChannel32AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.35 | Columnpmopm2CfgChannel33AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.36 | Columnpmopm2CfgChannel34AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.37 | Columnpmopm2CfgChannel35AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.38 | Columnpmopm2CfgChannel36AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.39 | Columnpmopm2CfgChannel37AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.40 | Columnpmopm2CfgChannel38AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.41 | Columnpmopm2CfgChannel39AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.42 | Columnpmopm2CfgChannel40AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.43 | Columnpmopm2CfgChannel41AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.44 | Columnpmopm2CfgChannel42AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.45 | Columnpmopm2CfgChannel43AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.46 | Columnpmopm2CfgChannel44AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.47 | Columnpmopm2CfgChannel45AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.48 | Columnpmopm2CfgChannel46AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.49 | Columnpmopm2CfgChannel47AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.50 | Columnpmopm2CfgChannel48AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.51 | Columnpmopm2CfgChannel49AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.52 | Columnpmopm2CfgChannel50AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.53 | Columnpmopm2CfgChannel51AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.54 | Columnpmopm2CfgChannel52AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.55 | Columnpmopm2CfgChannel53AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.56 | Columnpmopm2CfgChannel54AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.57 | Columnpmopm2CfgChannel55AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.58 | Columnpmopm2CfgChannel56AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.59 | Columnpmopm2CfgChannel57AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.60 | Columnpmopm2CfgChannel58AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.61 | Columnpmopm2CfgChannel59AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.62 | Columnpmopm2CfgChannel60AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.63 | Columnpmopm2CfgChannel61AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.64 | Columnpmopm2CfgChannel62AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.65 | Columnpmopm2CfgChannel63AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.66 | Columnpmopm2CfgChannel64AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.67 | Columnpmopm2CfgChannel65AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.68 | Columnpmopm2CfgChannel66AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.69 | Columnpmopm2CfgChannel67AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.70 | Columnpmopm2CfgChannel68AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.71 | Columnpmopm2CfgChannel69AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.72 | Columnpmopm2CfgChannel70AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.73 | Columnpmopm2CfgChannel71AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.74 | Columnpmopm2CfgChannel72AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.75 | Columnpmopm2CfgChannel73AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.76 | Columnpmopm2CfgChannel74AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.77 | Columnpmopm2CfgChannel75AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.78 | Columnpmopm2CfgChannel76AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.79 | Columnpmopm2CfgChannel77AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.80 | Columnpmopm2CfgChannel78AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.81 | Columnpmopm2CfgChannel79AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.82 | Columnpmopm2CfgChannel80AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.83 | Columnpmopm2CfgChannel81AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.84 | Columnpmopm2CfgChannel82AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.85 | Columnpmopm2CfgChannel83AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.86 | Columnpmopm2CfgChannel84AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.87 | Columnpmopm2CfgChannel85AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.88 | Columnpmopm2CfgChannel86AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.89 | Columnpmopm2CfgChannel87AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.90 | Columnpmopm2CfgChannel88AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.91 | Columnpmopm2CfgChannel89AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.92 | Columnpmopm2CfgChannel90AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.93 | Columnpmopm2CfgChannel91AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.94 | Columnpmopm2CfgChannel92AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.95 | Columnpmopm2CfgChannel93AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.96 | Columnpmopm2CfgChannel94AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.97 | Columnpmopm2CfgChannel95AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.4.1.98 | Columnpmopm2CfgChannel96AbsthreshPortn | read-write | current | Default Settings on Absence Threshold :This OID defines the threshold to consider a channel as absent |
| 1.3.6.1.4.1.20044.64.9.2.5 | Tablepmopm2CfgClientStartupPwrHighTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.64.9.2.5.1 | Rowpmopm2CfgClientStartupPwrHighEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.64.9.2.5.1.1 | Columnpmopm2CfgClientStartupPwrHighIndex | read-only | current | Index definition for the clientStartupPwrHigh table |
| 1.3.6.1.4.1.20044.64.9.2.5.1.3 | Columnpmopm2CfgChannel1PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.4 | Columnpmopm2CfgChannel2PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.5 | Columnpmopm2CfgChannel3PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.6 | Columnpmopm2CfgChannel4PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.7 | Columnpmopm2CfgChannel5PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.8 | Columnpmopm2CfgChannel6PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.9 | Columnpmopm2CfgChannel7PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.10 | Columnpmopm2CfgChannel8PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.11 | Columnpmopm2CfgChannel9PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.12 | Columnpmopm2CfgChannel10PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.13 | Columnpmopm2CfgChannel11PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.14 | Columnpmopm2CfgChannel12PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.15 | Columnpmopm2CfgChannel13PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.16 | Columnpmopm2CfgChannel14PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.17 | Columnpmopm2CfgChannel15PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.18 | Columnpmopm2CfgChannel16PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.19 | Columnpmopm2CfgChannel17PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.20 | Columnpmopm2CfgChannel18PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.21 | Columnpmopm2CfgChannel19PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.22 | Columnpmopm2CfgChannel20PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.23 | Columnpmopm2CfgChannel21PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.24 | Columnpmopm2CfgChannel22PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.25 | Columnpmopm2CfgChannel23PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.26 | Columnpmopm2CfgChannel24PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.27 | Columnpmopm2CfgChannel25PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.28 | Columnpmopm2CfgChannel26PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.29 | Columnpmopm2CfgChannel27PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.30 | Columnpmopm2CfgChannel28PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.31 | Columnpmopm2CfgChannel29PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.32 | Columnpmopm2CfgChannel30PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.33 | Columnpmopm2CfgChannel31PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.34 | Columnpmopm2CfgChannel32PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.35 | Columnpmopm2CfgChannel33PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.36 | Columnpmopm2CfgChannel34PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.37 | Columnpmopm2CfgChannel35PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.38 | Columnpmopm2CfgChannel36PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.39 | Columnpmopm2CfgChannel37PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.40 | Columnpmopm2CfgChannel38PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.41 | Columnpmopm2CfgChannel39PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.42 | Columnpmopm2CfgChannel40PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.43 | Columnpmopm2CfgChannel41PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.44 | Columnpmopm2CfgChannel42PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.45 | Columnpmopm2CfgChannel43PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.46 | Columnpmopm2CfgChannel44PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.47 | Columnpmopm2CfgChannel45PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.48 | Columnpmopm2CfgChannel46PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.49 | Columnpmopm2CfgChannel47PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.50 | Columnpmopm2CfgChannel48PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.51 | Columnpmopm2CfgChannel49PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.52 | Columnpmopm2CfgChannel50PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.53 | Columnpmopm2CfgChannel51PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.54 | Columnpmopm2CfgChannel52PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.55 | Columnpmopm2CfgChannel53PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.56 | Columnpmopm2CfgChannel54PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.57 | Columnpmopm2CfgChannel55PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.58 | Columnpmopm2CfgChannel56PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.59 | Columnpmopm2CfgChannel57PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.60 | Columnpmopm2CfgChannel58PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.61 | Columnpmopm2CfgChannel59PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.62 | Columnpmopm2CfgChannel60PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.63 | Columnpmopm2CfgChannel61PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.64 | Columnpmopm2CfgChannel62PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.65 | Columnpmopm2CfgChannel63PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.66 | Columnpmopm2CfgChannel64PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.67 | Columnpmopm2CfgChannel65PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.68 | Columnpmopm2CfgChannel66PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.69 | Columnpmopm2CfgChannel67PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.70 | Columnpmopm2CfgChannel68PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.71 | Columnpmopm2CfgChannel69PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.72 | Columnpmopm2CfgChannel70PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.73 | Columnpmopm2CfgChannel71PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.74 | Columnpmopm2CfgChannel72PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.75 | Columnpmopm2CfgChannel73PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.76 | Columnpmopm2CfgChannel74PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.77 | Columnpmopm2CfgChannel75PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.78 | Columnpmopm2CfgChannel76PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.79 | Columnpmopm2CfgChannel77PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.80 | Columnpmopm2CfgChannel78PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.81 | Columnpmopm2CfgChannel79PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.82 | Columnpmopm2CfgChannel80PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.83 | Columnpmopm2CfgChannel81PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.84 | Columnpmopm2CfgChannel82PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.85 | Columnpmopm2CfgChannel83PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.86 | Columnpmopm2CfgChannel84PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.87 | Columnpmopm2CfgChannel85PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.88 | Columnpmopm2CfgChannel86PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.89 | Columnpmopm2CfgChannel87PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.90 | Columnpmopm2CfgChannel88PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.91 | Columnpmopm2CfgChannel89PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.92 | Columnpmopm2CfgChannel90PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.93 | Columnpmopm2CfgChannel91PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.94 | Columnpmopm2CfgChannel92PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.95 | Columnpmopm2CfgChannel93PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.96 | Columnpmopm2CfgChannel94PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.97 | Columnpmopm2CfgChannel95PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.5.1.98 | Columnpmopm2CfgChannel96PwrhighPortn | read-write | current | Default Settings on Max Power :This OID defines the threshold to rise a channel power high |
| 1.3.6.1.4.1.20044.64.9.2.6 | Tablepmopm2CfgClientStartupPwrLowTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.64.9.2.6.1 | Rowpmopm2CfgClientStartupPwrLowEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.64.9.2.6.1.1 | Columnpmopm2CfgClientStartupPwrLowIndex | read-only | current | Index definition for the clientStartupPwrLow table |
| 1.3.6.1.4.1.20044.64.9.2.6.1.3 | Columnpmopm2CfgChannel1PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.4 | Columnpmopm2CfgChannel2PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.5 | Columnpmopm2CfgChannel3PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.6 | Columnpmopm2CfgChannel4PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.7 | Columnpmopm2CfgChannel5PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.8 | Columnpmopm2CfgChannel6PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.9 | Columnpmopm2CfgChannel7PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.10 | Columnpmopm2CfgChannel8PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.11 | Columnpmopm2CfgChannel9PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.12 | Columnpmopm2CfgChannel10PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.13 | Columnpmopm2CfgChannel11PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.14 | Columnpmopm2CfgChannel12PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.15 | Columnpmopm2CfgChannel13PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.16 | Columnpmopm2CfgChannel14PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.17 | Columnpmopm2CfgChannel15PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.18 | Columnpmopm2CfgChannel16PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.19 | Columnpmopm2CfgChannel17PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.20 | Columnpmopm2CfgChannel18PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.21 | Columnpmopm2CfgChannel19PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.22 | Columnpmopm2CfgChannel20PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.23 | Columnpmopm2CfgChannel21PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.24 | Columnpmopm2CfgChannel22PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.25 | Columnpmopm2CfgChannel23PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.26 | Columnpmopm2CfgChannel24PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.27 | Columnpmopm2CfgChannel25PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.28 | Columnpmopm2CfgChannel26PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.29 | Columnpmopm2CfgChannel27PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.30 | Columnpmopm2CfgChannel28PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.31 | Columnpmopm2CfgChannel29PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.32 | Columnpmopm2CfgChannel30PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.33 | Columnpmopm2CfgChannel31PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.34 | Columnpmopm2CfgChannel32PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.35 | Columnpmopm2CfgChannel33PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.36 | Columnpmopm2CfgChannel34PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.37 | Columnpmopm2CfgChannel35PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.38 | Columnpmopm2CfgChannel36PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.39 | Columnpmopm2CfgChannel37PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.40 | Columnpmopm2CfgChannel38PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.41 | Columnpmopm2CfgChannel39PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.42 | Columnpmopm2CfgChannel40PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.43 | Columnpmopm2CfgChannel41PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.44 | Columnpmopm2CfgChannel42PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.45 | Columnpmopm2CfgChannel43PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.46 | Columnpmopm2CfgChannel44PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.47 | Columnpmopm2CfgChannel45PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.48 | Columnpmopm2CfgChannel46PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.49 | Columnpmopm2CfgChannel47PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.50 | Columnpmopm2CfgChannel48PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.51 | Columnpmopm2CfgChannel49PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.52 | Columnpmopm2CfgChannel50PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.53 | Columnpmopm2CfgChannel51PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.54 | Columnpmopm2CfgChannel52PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.55 | Columnpmopm2CfgChannel53PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.56 | Columnpmopm2CfgChannel54PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.57 | Columnpmopm2CfgChannel55PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.58 | Columnpmopm2CfgChannel56PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.59 | Columnpmopm2CfgChannel57PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.60 | Columnpmopm2CfgChannel58PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.61 | Columnpmopm2CfgChannel59PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.62 | Columnpmopm2CfgChannel60PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.63 | Columnpmopm2CfgChannel61PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.64 | Columnpmopm2CfgChannel62PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.65 | Columnpmopm2CfgChannel63PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.66 | Columnpmopm2CfgChannel64PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.67 | Columnpmopm2CfgChannel65PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.68 | Columnpmopm2CfgChannel66PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.69 | Columnpmopm2CfgChannel67PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.70 | Columnpmopm2CfgChannel68PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.71 | Columnpmopm2CfgChannel69PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.72 | Columnpmopm2CfgChannel70PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.73 | Columnpmopm2CfgChannel71PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.74 | Columnpmopm2CfgChannel72PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.75 | Columnpmopm2CfgChannel73PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.76 | Columnpmopm2CfgChannel74PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.77 | Columnpmopm2CfgChannel75PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.78 | Columnpmopm2CfgChannel76PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.79 | Columnpmopm2CfgChannel77PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.80 | Columnpmopm2CfgChannel78PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.81 | Columnpmopm2CfgChannel79PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.82 | Columnpmopm2CfgChannel80PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.83 | Columnpmopm2CfgChannel81PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.84 | Columnpmopm2CfgChannel82PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.85 | Columnpmopm2CfgChannel83PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.86 | Columnpmopm2CfgChannel84PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.87 | Columnpmopm2CfgChannel85PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.88 | Columnpmopm2CfgChannel86PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.89 | Columnpmopm2CfgChannel87PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.90 | Columnpmopm2CfgChannel88PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.91 | Columnpmopm2CfgChannel89PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.92 | Columnpmopm2CfgChannel90PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.93 | Columnpmopm2CfgChannel91PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.94 | Columnpmopm2CfgChannel92PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.95 | Columnpmopm2CfgChannel93PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.96 | Columnpmopm2CfgChannel94PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.97 | Columnpmopm2CfgChannel95PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.6.1.98 | Columnpmopm2CfgChannel96PwrlowPortn | read-write | current | Default Settings on Min Power :This OID defines the threshold to rise a channel power low |
| 1.3.6.1.4.1.20044.64.9.2.7 | Tablepmopm2CfgLabelclientTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.64.9.2.7.1 | Rowpmopm2CfgLabelclientEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.64.9.2.7.1.1 | Columnpmopm2CfgLabelclientIndex | read-only | current | Index definition for the labelclient table |
| 1.3.6.1.4.1.20044.64.9.2.7.1.3 | Columnpmopm2CfgLabelclientPortn | read-write | current | Default settings on the label of the Ports : |
| 1.3.6.1.4.1.20044.64.9.2.8 | Tablepmopm2CfgLabellineTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.64.9.2.8.1 | Rowpmopm2CfgLabellineEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.64.9.2.8.1.1 | Columnpmopm2CfgLabellineIndex | read-only | current | Index definition for the labelline table |
| 1.3.6.1.4.1.20044.64.9.2.8.1.3 | Columnpmopm2CfgLabellinePortn | read-write | current | Default settings on the label of the lines : |
| 1.3.6.1.4.1.20044.64.9.257 | Scalarpmopm2CfgWriteConfiguration | read-write | current | Write configuration to module:This OID writes the complete configuration to the module |
| 1.3.6.1.4.1.20044.64.10 | Nodepmopm2traps | |||
| 1.3.6.1.4.1.20044.64.10.2 | Scalarpmopm2trapPortNumber | read-only | current | Last port which generates a trap |
| 1.3.6.1.4.1.20044.64.10.3 | Scalarpmopm2trapLineNumber | read-only | current | Last Line which generates a trap |
| 1.3.6.1.4.1.20044.64.10.4 | Scalarpmopm2trapBoardNumber | read-only | current | Last module which generates a trap |
| 1.3.6.1.4.1.20044.64.10.50 | Notificationpmopm2PowerTrapUrgentGoesOn | current | Urgent power supply default is activated | |
| 1.3.6.1.4.1.20044.64.10.51 | Notificationpmopm2PowerTrapUrgentGoesOff | current | Urgent power supply default disappeared |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| Pmopm2AdjustValue | INTEGER | current | different values for a client port |
| Pmopm2Grid | INTEGER { grid200(200), grid100(100), grid50(50) } | current | Different grids on the modules |
| Pmopm2MultiRate | INTEGER | current | different values for a client port |
| Pmopm2OtxChannel | INTEGER | current | different values for a client port |
| Pmopm2OtxMode | INTEGER | current | different values for a client port |