MIB Viewer

EKINOPS-Pmops-MIB

188 objects
MIB for the Ekinops Pmops hardware.
OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.30IdentitymodulePmopsMIB for the Ekinops Pmops hardware.
1.3.6.1.4.1.20044.30.2Nodepmopsalarms
1.3.6.1.4.1.20044.30.2.1NodepmopsAlmOther
1.3.6.1.4.1.20044.30.2.1.1NodepmopsAlmOtherNurg
1.3.6.1.4.1.20044.30.2.1.1.2NodepmopsAlmsynthAlm2
1.3.6.1.4.1.20044.30.2.1.1.2.1ScalarpmopsAlmConfTableSaveread-onlycurrentPM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> other…
1.3.6.1.4.1.20044.30.2.1.1.2.2ScalarpmopsAlmInvUploadread-onlycurrentInventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> other (1) <Alarmtype> other (1) <Polarit…
1.3.6.1.4.1.20044.30.2.1.1.2.3ScalarpmopsAlmConfTableLoadread-onlycurrentPM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> other (1) <Alarmt…
1.3.6.1.4.1.20044.30.2.1.1.2.4ScalarpmopsAlmCorrelatOffread-onlycurrentNot Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> other (1) <Alarmtype> other (1) <Pol…
1.3.6.1.4.1.20044.30.2.1.2NodepmopsAlmOtherUrg
1.3.6.1.4.1.20044.30.2.1.2.70NodepmopsAlmmodInitFailLevel2
1.3.6.1.4.1.20044.30.2.1.2.70.1ScalarpmopsAlmRegReadFailread-onlycurrentReg_Read_Fail : <Condtype> REG_READ_FAIL <Probcause> other (1) <Alarmtype> other (1) <Polarity> (2)
1.3.6.1.4.1.20044.30.2.1.2.70.2ScalarpmopsAlmResetHwInitFailread-onlycurrentReset_HW_Init_Fail : <Condtype> RESET_HW_INIT_FAIL <Probcause> other (1) <Alarmtype> other (1) <Polarity> (2)
1.3.6.1.4.1.20044.30.2.1.2.70.3ScalarpmopsAlmConfReadFailread-onlycurrentConf_Read_Fail : <Condtype> CONF_READ_FAIL <Probcause> other (1) <Alarmtype> other (1) <Polarity> (2)
1.3.6.1.4.1.20044.30.2.1.2.70.5ScalarpmopsAlmGwIdentFailread-onlycurrentGW_Ident_Fail :This OID indicates that GW identification has not been read <Condtype> GW_IDENT_FAIL <Probcause> other (1) <Alarmtype> other (1) <Polarity> (2)
1.3.6.1.4.1.20044.30.2.1.2.70.6ScalarpmopsAlmCalibReadFailread-onlycurrentCalib_Read_Fail : <Condtype> CALIB_READ_FAIL <Probcause> other (1) <Alarmtype> other (1) <Polarity> (2)
1.3.6.1.4.1.20044.30.2.1.2.70.7ScalarpmopsAlmThreshConfFailread-onlycurrentThresh_Conf_Fail : <Condtype> THRESH_CONF_FAIL <Probcause> other (1) <Alarmtype> other (1) <Polarity> (2)
1.3.6.1.4.1.20044.30.2.1.2.71NodepmopsAlmmodInitFailLevel3
1.3.6.1.4.1.20044.30.2.1.2.71.1ScalarpmopsAlmOptIdentFailread-onlycurrentOpt_Ident_Fail : <Condtype> OPT_IDENT_FAIL <Probcause> other (1) <Alarmtype> other (1) <Polarity> (2)
1.3.6.1.4.1.20044.30.2.1.2.71.5ScalarpmopsAlmGwColdBootForcedread-onlycurrentGW_Cold_Boot_Forced : <Condtype> GW_COLD_BOOT_FORCED <Probcause> other (1) <Alarmtype> other (1) <Polarity> (2)
1.3.6.1.4.1.20044.30.2.1.3NodepmopsAlmOtherCrit
1.3.6.1.4.1.20044.30.2.1.3.0NodepmopsAlmsynthAlm0
1.3.6.1.4.1.20044.30.2.1.3.0.9ScalarpmopsAlmModuleGlobFailureread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the PM <Condtype> MODULE_GLOB_FAILURE <Probcause> equipmentMalfunction (16) <Alarmty…
1.3.6.1.4.1.20044.30.2.1.3.0.15ScalarpmopsAlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.30.2.1.3.0.16ScalarpmopsAlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.30.2.2NodepmopsAlmComa
1.3.6.1.4.1.20044.30.2.2.1NodepmopsAlmComaNurg
1.3.6.1.4.1.20044.30.2.2.1.18NodepmopsAlmcomaMeasWng
1.3.6.1.4.1.20044.30.2.2.1.18.1ScalarpmopsAlmComaTx1PwrLowWngread-onlycurrentTx1 Low Warning :This OID indicates that Transmit power or the OPS A is lower than the warning threshold of the OPS A <Help> This warning indicates if the rece…
1.3.6.1.4.1.20044.30.2.2.1.18.2ScalarpmopsAlmComaTx1PwrHighWngread-onlycurrentTx1 High Warning : This OID indicates that Transmit power or the OPS A is higher than the warning threshold of the OPS A <Help> This warning indicates if the r…
1.3.6.1.4.1.20044.30.2.2.1.18.3ScalarpmopsAlmComaRx1PwrLowWngread-onlycurrentRx1 Low Warning :This OID indicates that Receive power or the OPS A is lower than the warning threshold of the OPS A <Help> This warning indicates if the recei…
1.3.6.1.4.1.20044.30.2.2.1.18.4ScalarpmopsAlmComaRx1PwrHighWngread-onlycurrentRx1 High Warning : This OID indicates that Receive power or the OPS A is higher than the warning threshold of the OPS A <Help> This warning indicates if the re…
1.3.6.1.4.1.20044.30.2.2.1.18.5ScalarpmopsAlmComaTx2PwrLowWngread-onlycurrentTx2 Low Warning :This OID indicates that Transmit power or the OPS A is lower than the warning threshold of the OPS A <Help> This warning indicates if the rece…
1.3.6.1.4.1.20044.30.2.2.1.18.6ScalarpmopsAlmComaTx2PwrHighWngread-onlycurrentTx2 High Warning : This OID indicates that Transmit power or the OPS A is higher than the warning threshold of the OPS A <Help> This warning indicates if the r…
1.3.6.1.4.1.20044.30.2.2.1.18.7ScalarpmopsAlmComaRx2PwrLowWngread-onlycurrentRx2 Low Warning :This OID indicates that Receive power or the OPS A is lower than the warning threshold of the OPS A <Help> This warning indicates if the recei…
1.3.6.1.4.1.20044.30.2.2.1.18.8ScalarpmopsAlmComaRx2PwrHighWngread-onlycurrentRx2 High Warning : This OID indicates that Receive power or the OPS A is higher than the warning threshold of the OPS A <Help> This warning indicates if the re…
1.3.6.1.4.1.20044.30.2.2.2NodepmopsAlmComaUrg
1.3.6.1.4.1.20044.30.2.2.2.16NodepmopsAlmcomaAccessioAlm
1.3.6.1.4.1.20044.30.2.2.2.16.1ScalarpmopsAlmComaLosRx1read-onlycurrentRX1 Loss Of Signal :This OID indicates that a LOS is detected on the Receive 1 of the OPS A <Help> This alarm indicates if an optical signal is detected on the…
1.3.6.1.4.1.20044.30.2.2.2.16.2ScalarpmopsAlmComaLosRx2read-onlycurrentRX2 Loss Of Signal :This OID indicates that a LOS is detected on the Receive 2 of the OPS A <Help> This alarm indicates if an optical signal is detected on the…
1.3.6.1.4.1.20044.30.2.2.2.16.3ScalarpmopsAlmComaLosTx1read-onlycurrentTX1 Loss Of Signal :This OID indicates that a LOS is detected on the Transmit 1 of the OPS A <Help> This alarm indicates if an optical signal is detected on th…
1.3.6.1.4.1.20044.30.2.2.2.16.4ScalarpmopsAlmComaLosTx2read-onlycurrentTX2 Loss Of Signal :This OID indicates that a LOS is detected on the Transmit 2 of the OPS A <Help> This alarm indicates if an optical signal is detected on th…
1.3.6.1.4.1.20044.30.2.2.2.16.5ScalarpmopsAlmComaSwitchPosition1read-onlycurrentRX1 Selected :This OID indicates the OPS A selects the RX 1 input <Help> This status indicates if the RX 1 input is selected on the OPS A <Condtype> COMA_SWITC…
1.3.6.1.4.1.20044.30.2.2.2.16.6ScalarpmopsAlmComaSwitchPosition2read-onlycurrentRX2 Selected :This OID indicates the OPS A selects the RX 2 input <Help> This status indicates if the RX2 input is selected on the OPS A <Condtype> COMA_SWITCH…
1.3.6.1.4.1.20044.30.2.2.2.16.8ScalarpmopsAlmComaSwitchFailread-onlycurrentSwitch Fail :This OID indicates the OPS A switch component in in fail condition <Help> This alarm indicates if the OPS A swithc is in fail condition <Condtype>…
1.3.6.1.4.1.20044.30.2.2.2.17NodepmopsAlmcomaMeasAlm
1.3.6.1.4.1.20044.30.2.2.2.17.1ScalarpmopsAlmComaTx1PwrLowAlaread-onlycurrentTx1 Low Alarm :This OID indicates that Transmit power or the OPS A is lower than the alarm threshold of the OPS A <Help> This alarm indicates if the receive po…
1.3.6.1.4.1.20044.30.2.2.2.17.2ScalarpmopsAlmComaTx1PwrHighAlaread-onlycurrentTx1 High Alarm : This OID indicates that Transmit power or the OPS A is higher than the alarm threshold of the OPS A <Help> This alarm indicates if the receive…
1.3.6.1.4.1.20044.30.2.2.2.17.3ScalarpmopsAlmComaRx1PwrLowAlaread-onlycurrentRx1 Low Alarm :This OID indicates that Receive power or the OPS A is lower than the alarm threshold of the OPS A <Help> This alarm indicates if the receive pow…
1.3.6.1.4.1.20044.30.2.2.2.17.4ScalarpmopsAlmComaRx1PwrHighAlaread-onlycurrentRx1 High Alarm : This OID indicates that Receive power or the OPS A is higher than the alarm threshold of the OPS A <Help> This alarm indicates if the receive …
1.3.6.1.4.1.20044.30.2.2.2.17.5ScalarpmopsAlmComaTx2PwrLowAlaread-onlycurrentTx2 Low Alarm :This OID indicates that Transmit power or the OPS A is lower than the alarm threshold of the OPS A <Help> This alarm indicates if the receive po…
1.3.6.1.4.1.20044.30.2.2.2.17.6ScalarpmopsAlmComaTx2PwrHighAlaread-onlycurrentTx2 High Alarm : This OID indicates that Transmit power or the OPS A is higher than the alarm threshold of the OPS A <Help> This alarm indicates if the receive…
1.3.6.1.4.1.20044.30.2.2.2.17.7ScalarpmopsAlmComaRx2PwrLowAlaread-onlycurrentRx2 Low Alarm :This OID indicates that Receive power or the OPS A is lower than the alarm threshold of the OPS A <Help> This alarm indicates if the receive pow…
1.3.6.1.4.1.20044.30.2.2.2.17.8ScalarpmopsAlmComaRx2PwrHighAlaread-onlycurrentRx2 High Alarm : This OID indicates that Receive power or the OPS A is higher than the alarm threshold of the OPS A <Help> This alarm indicates if the receive …
1.3.6.1.4.1.20044.30.2.2.3NodepmopsAlmComaCrit
1.3.6.1.4.1.20044.30.2.2.3.8NodepmopsAlmsynthAlmComa
1.3.6.1.4.1.20044.30.2.2.3.8.4ScalarpmopsAlmComaHwFailAccread-onlycurrentHW_Fail_Acc :This OID indicates a hardware failure on the OPS A <Condtype> COMA_HW_FAIL_ACC <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (1…
1.3.6.1.4.1.20044.30.2.2.3.8.6ScalarpmopsAlmComaLocalOosread-onlycurrentOut Of Service :This OID indicates that the OPS A is In Service (1) of Out or Service (2). <Help> This status indicates if the OPS A is in service <Condtype> C…
1.3.6.1.4.1.20044.30.2.2.3.8.9ScalarpmopsAlmComaMeasWngread-onlycurrentMeasure Warning :This OID indicates a warning is present coming out of OPS A diagnostic monitoring <Help> This alarm indicates if a diagnostic monitoring Warni…
1.3.6.1.4.1.20044.30.2.2.3.8.10ScalarpmopsAlmComaMeasAlmread-onlycurrentMeasure Alarm :This OID indicates an alarm is present coming out of OPS A diagnostic monitoring <Help> This alarm indicates if a diagnostic monitoring Alarm ha…
1.3.6.1.4.1.20044.30.2.2.3.8.12ScalarpmopsAlmComaFailAccread-onlycurrentFail_Acc :This OID indicates a failure on the OPS A <Condtype> COMA_FAIL_ACC <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12) <Polarity> (…
1.3.6.1.4.1.20044.30.2.3NodepmopsAlmComb
1.3.6.1.4.1.20044.30.2.3.1NodepmopsAlmCombNurg
1.3.6.1.4.1.20044.30.2.3.1.26NodepmopsAlmcombMeasWng
1.3.6.1.4.1.20044.30.2.3.1.26.1ScalarpmopsAlmCombTx1PwrLowWngread-onlycurrentTx1 Low Warning :This OID indicates that Transmit power or the OPS B is lower than the warning threshold of the OPS B <Help> This warning indicates if the rece…
1.3.6.1.4.1.20044.30.2.3.1.26.2ScalarpmopsAlmCombTx1PwrHighWngread-onlycurrentTx1 High Warning : This OID indicates that Transmit power or the OPS B is higher than the warning threshold of the OPS B <Help> This warning indicates if the r…
1.3.6.1.4.1.20044.30.2.3.1.26.3ScalarpmopsAlmCombRx1PwrLowWngread-onlycurrentRx1 Low Warning :This OID indicates that Receive power or the OPS B is lower than the warning threshold of the OPS B <Help> This warning indicates if the recei…
1.3.6.1.4.1.20044.30.2.3.1.26.4ScalarpmopsAlmCombRx1PwrHighWngread-onlycurrentRx1 High Warning : This OID indicates that Receive power or the OPS B is higher than the warning threshold of the OPS B <Help> This warning indicates if the re…
1.3.6.1.4.1.20044.30.2.3.1.26.5ScalarpmopsAlmCombTx2PwrLowWngread-onlycurrentTx2 Low Warning :This OID indicates that Transmit power or the OPS B is lower than the warning threshold of the OPS B <Help> This warning indicates if the rece…
1.3.6.1.4.1.20044.30.2.3.1.26.6ScalarpmopsAlmCombTx2PwrHighWngread-onlycurrentTx2 High Warning : This OID indicates that Transmit power or the OPS B is higher than the warning threshold of the OPS B <Help> This warning indicates if the r…
1.3.6.1.4.1.20044.30.2.3.1.26.7ScalarpmopsAlmCombRx2PwrLowWngread-onlycurrentRx2 Low Warning :This OID indicates that Receive power or the OPS B is lower than the warning threshold of the OPS B <Help> This warning indicates if the recei…
1.3.6.1.4.1.20044.30.2.3.1.26.8ScalarpmopsAlmCombRx2PwrHighWngread-onlycurrentRx2 High Warning : This OID indicates that Receive power or the OPS B is higher than the warning threshold of the OPS B <Help> This warning indicates if the re…
1.3.6.1.4.1.20044.30.2.3.2NodepmopsAlmCombUrg
1.3.6.1.4.1.20044.30.2.3.2.24NodepmopsAlmcombAccessioAlm
1.3.6.1.4.1.20044.30.2.3.2.24.1ScalarpmopsAlmCombLosRx1read-onlycurrentRX1 Loss Of Signal :This OID indicates that a LOS is detected on the Receive 1 of the OPS B <Help> This alarm indicates if an optical signal is detected on the…
1.3.6.1.4.1.20044.30.2.3.2.24.2ScalarpmopsAlmCombLosRx2read-onlycurrentRX2 Loss Of Signal :This OID indicates that a LOS is detected on the Receive 2 of the OPS B <Help> This alarm indicates if an optical signal is detected on the…
1.3.6.1.4.1.20044.30.2.3.2.24.3ScalarpmopsAlmCombLosTx1read-onlycurrentTX1 Loss Of Signal :This OID indicates that a LOS is detected on the Transmit 1 of the OPS B <Help> This alarm indicates if an optical signal is detected on th…
1.3.6.1.4.1.20044.30.2.3.2.24.4ScalarpmopsAlmCombLosTx2read-onlycurrentTX2 Loss Of Signal :This OID indicates that a LOS is detected on the Transmit 2 of the OPS B <Help> This alarm indicates if an optical signal is detected on th…
1.3.6.1.4.1.20044.30.2.3.2.24.5ScalarpmopsAlmCombSwitchPosition1read-onlycurrentRX1 Selected :This OID indicates the OPS B selects the RX 1 input <Help> This status indicates if the RX 1 input is selected on the OPS B <Condtype> COMB_SWITC…
1.3.6.1.4.1.20044.30.2.3.2.24.6ScalarpmopsAlmCombSwitchPosition2read-onlycurrentRX2 Selected :This OID indicates the OPS B selects the RX 2 input <Help> This status indicates if the RX2 input is selected on the OPS B <Condtype> COMB_SWITCH…
1.3.6.1.4.1.20044.30.2.3.2.24.8ScalarpmopsAlmCombSwitchFailread-onlycurrentSwitch Fail :This OID indicates the OPS B switch component in in fail condition <Help> This alarm indicates if the OPS B swithc is in fail condition <Condtype>…
1.3.6.1.4.1.20044.30.2.3.2.25NodepmopsAlmcombMeasAla
1.3.6.1.4.1.20044.30.2.3.2.25.1ScalarpmopsAlmCombTx1PwrLowAlaread-onlycurrentTx1 Low Alarm :This OID indicates that Transmit power or the OPS B is lower than the alarm threshold of the OPS B <Help> This alarm indicates if the receive po…
1.3.6.1.4.1.20044.30.2.3.2.25.2ScalarpmopsAlmCombTx1PwrHighAlaread-onlycurrentTx1 High Alarm : This OID indicates that Transmit power or the OPS B is higher than the alarm threshold of the OPS B <Help> This alarm indicates if the receive…
1.3.6.1.4.1.20044.30.2.3.2.25.3ScalarpmopsAlmCombRx1PwrLowAlaread-onlycurrentRx1 Low Alarm :This OID indicates that Receive power or the OPS B is lower than the alarm threshold of the OPS B <Help> This alarm indicates if the receive pow…
1.3.6.1.4.1.20044.30.2.3.2.25.4ScalarpmopsAlmCombRx1PwrHighAlaread-onlycurrentRx1 High Alarm : This OID indicates that Receive power or the OPS B is higher than the alarm threshold of the OPS B <Help> This alarm indicates if the receive …
1.3.6.1.4.1.20044.30.2.3.2.25.5ScalarpmopsAlmCombTx2PwrLowAlaread-onlycurrentTx2 Low Alarm :This OID indicates that Transmit power or the OPS B is lower than the alarm threshold of the OPS B <Help> This alarm indicates if the receive po…
1.3.6.1.4.1.20044.30.2.3.2.25.6ScalarpmopsAlmCombTx2PwrHighAlaread-onlycurrentTx2 High Alarm : This OID indicates that Transmit power or the OPS B is higher than the alarm threshold of the OPS B <Help> This alarm indicates if the receive…
1.3.6.1.4.1.20044.30.2.3.2.25.7ScalarpmopsAlmCombRx2PwrLowAlaread-onlycurrentRx2 Low Alarm :This OID indicates that Receive power or the OPS B is lower than the alarm threshold of the OPS B <Help> This alarm indicates if the receive pow…
1.3.6.1.4.1.20044.30.2.3.2.25.8ScalarpmopsAlmCombRx2PwrHighAlaread-onlycurrentRx2 High Alarm : This OID indicates that Receive power or the OPS B is higher than the alarm threshold of the OPS B <Help> This alarm indicates if the receive …
1.3.6.1.4.1.20044.30.2.3.3NodepmopsAlmCombCrit
1.3.6.1.4.1.20044.30.2.3.3.9NodepmopsAlmsynthAlmComb
1.3.6.1.4.1.20044.30.2.3.3.9.4ScalarpmopsAlmCombHwFailAccread-onlycurrentHW_Fail_Acc :This OID indicates a hardware failure on the OPS B <Condtype> COMB_HW_FAIL_ACC <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (1…
1.3.6.1.4.1.20044.30.2.3.3.9.6ScalarpmopsAlmCombLocalOosread-onlycurrentOut Of Service :This OID indicates that the OPS B is In Service (1) of Out or Service (2). <Help> This status indicates if the OPS B is in service <Condtype> C…
1.3.6.1.4.1.20044.30.2.3.3.9.9ScalarpmopsAlmCombMeasWngread-onlycurrentMeasure Warning :This OID indicates a warning is present coming out of OPS B diagnostic monitoring <Help> This alarm indicates if a diagnostic monitoring Warni…
1.3.6.1.4.1.20044.30.2.3.3.9.10ScalarpmopsAlmCombMeasAlmread-onlycurrentMeasure Alarm :This OID indicates an alarm is present coming out of OPS B diagnostic monitoring <Help> This alarm indicates if a diagnostic monitoring Alarm ha…
1.3.6.1.4.1.20044.30.2.3.3.9.12ScalarpmopsAlmCombFailAccread-onlycurrentFail_Acc :This OID indicates a failure on the OPS B <Condtype> COMB_FAIL_ACC <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12) <Polarity> (…
1.3.6.1.4.1.20044.30.3Nodepmopsmeasures
1.3.6.1.4.1.20044.30.3.1NodepmopsMesrOther
1.3.6.1.4.1.20044.30.3.2NodepmopsMesrComa
1.3.6.1.4.1.20044.30.3.2.16ScalarpmopsMesrcomaTxPower1read-onlycurrentTX1 Power :This OID gives the transmit power value of the signal , read on the coupler output 1 (Power=(AV-32768)*0.005) (Unit = dBm) <Help> This measure gives…
1.3.6.1.4.1.20044.30.3.2.17ScalarpmopsMesrcomaTxPower2read-onlycurrentTX2 Power :This OID gives the transmit power value of the signal , read on the coupler output 2 (Power=(AV-32768)*0.005) (Unit = dBm) <Help> This measure gives…
1.3.6.1.4.1.20044.30.3.2.18ScalarpmopsMesrcomaRxPower1read-onlycurrentRX1 Power :This OID gives the receive power value of the signal , read on the switch input 1 (Power=(AV-32768)*0.005) (Unit = dBm) <Help> This measure gives th…
1.3.6.1.4.1.20044.30.3.2.19ScalarpmopsMesrcomaRxPower2read-onlycurrentRX2 Power :This OID gives the receive power value of the signal , read on the switch input 2 (Power=(AV-32768)*0.005) (Unit = dBm) <Help> This measure gives th…
1.3.6.1.4.1.20044.30.3.3NodepmopsMesrComb
1.3.6.1.4.1.20044.30.3.3.24ScalarpmopsMesrcombTxPower1read-onlycurrentTX1 Power :This OID gives the transmit power value of the signal , read on the coupler output 1 (Power=(AV-32768)*0.005) (Unit = dBm) <Help> This measure gives…
1.3.6.1.4.1.20044.30.3.3.25ScalarpmopsMesrcombTxPower2read-onlycurrentTX2 Power :This OID gives the transmit power value of the signal , read on the coupler output 2 (Power=(AV-32768)*0.005) (Unit = dBm) <Help> This measure gives…
1.3.6.1.4.1.20044.30.3.3.26ScalarpmopsMesrcombRxPower1read-onlycurrentRX1 Power :This OID gives the receive power value of the signal , read on the switch input 1 (Power=(AV-32768)*0.005) (Unit = dBm) <Help> This measure gives th…
1.3.6.1.4.1.20044.30.3.3.27ScalarpmopsMesrcombRxPower2read-onlycurrentRX2 Power :This OID gives the receive power value of the signal , read on the switch input 2 (Power=(AV-32768)*0.005) (Unit = dBm) <Help> This measure gives th…
1.3.6.1.4.1.20044.30.6NodepmopscontrolsWrite
1.3.6.1.4.1.20044.30.6.1NodepmopsCtrlOther
1.3.6.1.4.1.20044.30.6.1.0NodepmopsCtrlsynth0
1.3.6.1.4.1.20044.30.6.1.0.1ScalarpmopsCtrlConfLoadread-writecurrentLoad Configuration Tables :When set this enables loading from flash configuration1 into the module.
1.3.6.1.4.1.20044.30.6.1.0.9ScalarpmopsCtrlConfFlashread-writecurrentWrite Configuration Tables :This bit saves the current configuration of the module as configuration in the flash. <Help> This control saves the customer config…
1.3.6.1.4.1.20044.30.6.1.0.13ScalarpmopsCtrlConfClearread-writecurrentClear Configuration Tables :This bit clears the configuration tables from configuration in the flash. <Help> This control restores the default configuration of…
1.3.6.1.4.1.20044.30.6.1.4NodepmopsCtrlsynth4
1.3.6.1.4.1.20044.30.6.1.4.1ScalarpmopsCtrlCorrelatOnread-writecurrentEnable Alarm Correlation :This OID enables the alarm correlation in the PM.
1.3.6.1.4.1.20044.30.6.1.4.2ScalarpmopsCtrlCorrelatOffread-writecurrentDisable Alarm Correlation :This OID disables the alarm correlation in the PM.
1.3.6.1.4.1.20044.30.6.1.5NodepmopsCtrlswMgnt
1.3.6.1.4.1.20044.30.6.1.5.2ScalarpmopsCtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the Software. This reset is traffic affecting, and the configuration of Software is reloaded on start…
1.3.6.1.4.1.20044.30.6.1.5.3ScalarpmopsCtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the Software. This reset is not traffic affecting, and the configuration of the Sofwtare remains unch…
1.3.6.1.4.1.20044.30.6.1.64NodepmopsCtrlledTest
1.3.6.1.4.1.20044.30.6.1.64.1ScalarpmopsCtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.30.6.1.64.2ScalarpmopsCtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.30.6.1.64.3ScalarpmopsCtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.30.6.2NodepmopsCtrlComa
1.3.6.1.4.1.20044.30.6.2.16ScalarpmopsCtrlcomaSwitchModeread-writecurrentSwitch Mode :This OID sets the switch mode of the OPS A <Help> This control defines the switch mode of the OPS A (Manual 1, Manual 2, Auto reversive or auto no…
1.3.6.1.4.1.20044.30.6.2.18NodepmopsCtrlcomaOosMode
1.3.6.1.4.1.20044.30.6.2.18.1ScalarpmopsCtrlComaOosModeread-writecurrentOut Of Service :This OID sets the OPS A Out of Service <Help> This controls defines the service state of the OPS A
1.3.6.1.4.1.20044.30.6.2.24ScalarpmopsCtrlcomaRxPwrSetting1read-writecurrentRX1 Loss Threshold :This OID sets the LOS detection threshold on the RX1 of the OPS A (AV=Power/0.005 + 32768) (Unit = dBm) <Help> This control defines the LOS…
1.3.6.1.4.1.20044.30.6.2.25ScalarpmopsCtrlcomaRxPwrSetting2read-writecurrentRX2 Loss Threshold :This OID sets the LOS detection threshold on the RX2 of the OPS A (AV=Power/0.005 + 32768) (Unit = dBm) <Help> This control defines the LOS…
1.3.6.1.4.1.20044.30.6.3NodepmopsCtrlComb
1.3.6.1.4.1.20044.30.6.3.17ScalarpmopsCtrlcombSwitchModeread-writecurrentSwitch Mode :This OID sets the switch mode of the OPS B <Help> This control defines the switch mode of the OPS B (Manual 1, Manual 2, Auto reversive or auto no…
1.3.6.1.4.1.20044.30.6.3.19NodepmopsCtrlcombOosMode
1.3.6.1.4.1.20044.30.6.3.19.1ScalarpmopsCtrlCombOosModeread-writecurrentOut Of Service :This OID sets the OPS B Out of Service <Help> This controls defines the service state of the OPS B
1.3.6.1.4.1.20044.30.6.3.26ScalarpmopsCtrlcombRxPwrSetting1read-writecurrentRX1 Loss Threshold :This OID sets the LOS detection threshold on the RX1 of the OPS B (AV=Power/0.005 + 32768) (Unit = dBm) <Help> This control defines the LOS…
1.3.6.1.4.1.20044.30.6.3.27ScalarpmopsCtrlcombRxPwrSetting2read-writecurrentRX2 Loss Threshold :This OID sets the LOS detection threshold on the RX2 of the OPS B (AV=Power/0.005 + 32768) (Unit = dBm) <Help> This control defines the LOS…
1.3.6.1.4.1.20044.30.7Nodepmopsri
1.3.6.1.4.1.20044.30.7.1NodepmopsriTable
1.3.6.1.4.1.20044.30.7.2ScalarpmopsRinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.30.7.3ScalarpmopsRinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.30.7.4ScalarpmopsRinvModulePlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.30.7.5ScalarpmopsRinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.30.7.6ScalarpmopsRinvLine1SFPread-onlycurrentInventory for the OPS: This OID contains the inventory for the OPS A
1.3.6.1.4.1.20044.30.7.7ScalarpmopsRinvLine2SFPread-onlycurrentInventory for the OPS: This OID contains the inventory for the OPS B
1.3.6.1.4.1.20044.30.9NodepmopsConfig
1.3.6.1.4.1.20044.30.9.1NodepmopsCfgLsd
1.3.6.1.4.1.20044.30.9.1.1NodepmopstablecomaLsd
1.3.6.1.4.1.20044.30.9.2NodepmopsCfgStartUp
1.3.6.1.4.1.20044.30.9.2.1NodepmopstablecomaStartup
1.3.6.1.4.1.20044.30.9.2.1.2ScalarpmopsCfgcomaSwitchModeread-writecurrentDefault setting on OPS A switch :This register configures the default switch mode on OPS A
1.3.6.1.4.1.20044.30.9.2.1.3ScalarpmopsCfgcomaRxPwrSetting1read-writecurrentDefault setting on OPS A Rx Pwr 1 :This register configures the default RX1 Loss threshold on the OPS A (Unit = dBm)
1.3.6.1.4.1.20044.30.9.2.1.4ScalarpmopsCfgcomaRxPwrSetting2read-writecurrentDefault setting on OPS A Rx Pwr 2 :This register configures the default RX2 Loss threshold on the OPS A (Unit = dBm)
1.3.6.1.4.1.20044.30.9.2.1.5ScalarpmopsCfgcomaOosModeread-writecurrentDefault Setting on OPS A :This register configures the default modes on OPS A
1.3.6.1.4.1.20044.30.9.2.2NodepmopstablecombStartup
1.3.6.1.4.1.20044.30.9.2.2.2ScalarpmopsCfgcombSwitchModeread-writecurrentDefault setting on OPS B switch :This register configures the default switch mode on OPS B
1.3.6.1.4.1.20044.30.9.2.2.3ScalarpmopsCfgcombRxPwrSetting1read-writecurrentDefault setting on OPS B Rx Pwr 1 :This register configures the default RX1 Loss threshold on the OPS B (Unit = dBm)
1.3.6.1.4.1.20044.30.9.2.2.4ScalarpmopsCfgcombRxPwrSetting2read-writecurrentDefault setting on OPS B Rx Pwr 2 :This register configures the default RX2 Loss threshold on the OPS B (Unit = dBm)
1.3.6.1.4.1.20044.30.9.2.2.5ScalarpmopsCfgcombOosModeread-writecurrentDefault Setting on OPS B :This register configures the default modes on OPS B
1.3.6.1.4.1.20044.30.9.3NodepmopsCfgLabels
1.3.6.1.4.1.20044.30.9.3.1TablepmopsCfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.30.9.3.1.1RowpmopsCfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.30.9.3.1.1.1ColumnpmopsCfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.30.9.3.1.1.3ColumnpmopsCfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.30.9.3.2TablepmopsCfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.30.9.3.2.1RowpmopsCfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.30.9.3.2.1.1ColumnpmopsCfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.30.9.3.2.1.3ColumnpmopsCfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.30.9.257ScalarpmopsCfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.30.10Nodepmopstraps
1.3.6.1.4.1.20044.30.10.2ScalarpmopstrapPortNumberread-onlycurrentLast port which generates a trap
1.3.6.1.4.1.20044.30.10.3ScalarpmopstrapLineNumberread-onlycurrentLast Line which generates a trap
1.3.6.1.4.1.20044.30.10.4ScalarpmopstrapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.30.10.30NotificationpmopsComBTrapNotUrgentGoesOncurrentNot urgent Line default is activated
1.3.6.1.4.1.20044.30.10.31NotificationpmopsComBTrapNotUrgentGoesOffcurrentNot urgent Line default disappeared
1.3.6.1.4.1.20044.30.10.32NotificationpmopsComBTrapUrgentGoesOncurrentUrgent Line default is activated
1.3.6.1.4.1.20044.30.10.33NotificationpmopsComBTrapUrgentGoesOffcurrentUrgent Line default disappeared
1.3.6.1.4.1.20044.30.10.34NotificationpmopsComBTrapCritGoesOncurrentCritical Line default is activated
1.3.6.1.4.1.20044.30.10.35NotificationpmopsComBTrapCritGoesOffcurrentCritical Line default disappeared
1.3.6.1.4.1.20044.30.10.40NotificationpmopsComATrapNotUrgentGoesOncurrentNot urgent client default is activated
1.3.6.1.4.1.20044.30.10.41NotificationpmopsComATrapNotUrgentGoesOffcurrentNot urgent client default disappeared
1.3.6.1.4.1.20044.30.10.42NotificationpmopsComATrapUrgentGoesOncurrentUrgent client default is activated
1.3.6.1.4.1.20044.30.10.43NotificationpmopsComATrapUrgentGoesOffcurrentUrgent client default disappeared
1.3.6.1.4.1.20044.30.10.44NotificationpmopsComATrapCritGoesOncurrentCritical client default is activated
1.3.6.1.4.1.20044.30.10.45NotificationpmopsComATrapCritGoesOffcurrentCritical client default disappeared
1.3.6.1.4.1.20044.30.10.50NotificationpmopsPowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.30.10.51NotificationpmopsPowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared
Type Definitions
NameSyntaxStatusDescription
PmopsSwitchModeINTEGER { switchManual1(1), switchManual2(2), switchAuto(4), switchAutoRevertive(8) }currentdifferent switch mode for port