1.3.6.1.4.1.20044.72Identitymodulepmora14Creation
1.3.6.1.4.1.20044.72.2Nodepmora14alarms
1.3.6.1.4.1.20044.72.2.1Nodepmora14AlmOther
1.3.6.1.4.1.20044.72.2.1.1Nodepmora14AlmOtherNurg
1.3.6.1.4.1.20044.72.2.1.1.2Nodepmora14AlmsynthAlm2
1.3.6.1.4.1.20044.72.2.1.1.2.1Scalarpmora14AlmConfTableSaveread-onlycurrentPM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> other…
1.3.6.1.4.1.20044.72.2.1.1.2.2Scalarpmora14AlmInvUploadread-onlycurrentInventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> other (1) <Alarmtype> other (1) <Polarit…
1.3.6.1.4.1.20044.72.2.1.1.2.3Scalarpmora14AlmConfTableLoadread-onlycurrentPM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> other (1) <Alarmt…
1.3.6.1.4.1.20044.72.2.1.1.75Nodepmora14AlmmoduleWarnings
1.3.6.1.4.1.20044.72.2.1.1.75.1Scalarpmora14AlmModuleTempLowWarningread-onlycurrentModule Temperature Low Warning :This OID indicates that the PM temperature if lower than the Warning threshold <Help> This alarm indicates if the module temper…
1.3.6.1.4.1.20044.72.2.1.1.75.2Scalarpmora14AlmModuleTempHighWarningread-onlycurrentModule Temperature High Warning :This OID indicates that the PM temperature if higher than the Warning threshold <Help> This alarm indicates if the module temp…
1.3.6.1.4.1.20044.72.2.1.2Nodepmora14AlmOtherUrg
1.3.6.1.4.1.20044.72.2.1.2.74Nodepmora14AlmmoduleAlarms
1.3.6.1.4.1.20044.72.2.1.2.74.1Scalarpmora14AlmModuleTempLowAlarmread-onlycurrentModule Temperature Low Alarm :This OID indicates that the PM temperature if lower than the alarm threshold <Help> This alarm indicates if the module temperatur…
1.3.6.1.4.1.20044.72.2.1.2.74.2Scalarpmora14AlmModuleTempHighAlarmread-onlycurrentModule Temperature High Alarm :This OID indicates that the PM temperature is higher than the alarm threshold <Help> This alarm indicates if the module temperat…
1.3.6.1.4.1.20044.72.2.1.3Nodepmora14AlmOtherCrit
1.3.6.1.4.1.20044.72.2.1.3.0Nodepmora14AlmsynthAlm0
1.3.6.1.4.1.20044.72.2.1.3.0.1Scalarpmora14AlmMaintenanceModeread-onlycurrentMaintenance Mode :This OID indicates that the PM is in maintenance mode <Help> This status indiates if the module is currently in maintenance mode <Condtype> M…
1.3.6.1.4.1.20044.72.2.1.3.0.2Scalarpmora14AlmAprOnread-onlycurrentAutomatic Power Reduction :This OID indicates that the APR algorithm has been operated and the output of the lasers are shutdown <Help> The APR algorithm has b…
1.3.6.1.4.1.20044.72.2.1.3.0.9Scalarpmora14AlmModGlobFailread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the PM <Help> This alarm <Condtype> MOD_GLOB_FAIL <Probcause> equipmentMalfunction (…
1.3.6.1.4.1.20044.72.2.1.3.0.10Scalarpmora14AlmInitNotComplread-onlycurrentRaman Module Not Initialized :This OID indicates that the initialisation of the Raman module is not completed <Help> This status indicates if the Raman has bee…
1.3.6.1.4.1.20044.72.2.1.3.0.15Scalarpmora14AlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.72.2.1.3.0.16Scalarpmora14AlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.72.2.2Nodepmora14AlmClient
1.3.6.1.4.1.20044.72.2.2.1Nodepmora14AlmClientNurg
1.3.6.1.4.1.20044.72.2.2.2Nodepmora14AlmClientUrg
1.3.6.1.4.1.20044.72.2.2.3Nodepmora14AlmClientCrit
1.3.6.1.4.1.20044.72.2.3Nodepmora14AlmLine
1.3.6.1.4.1.20044.72.2.3.1Nodepmora14AlmLineNurg
1.3.6.1.4.1.20044.72.2.3.1.33Nodepmora14AlmclientOraaWarnings
1.3.6.1.4.1.20044.72.2.3.1.33.1Scalarpmora14AlmPump1CurrentHighWarningread-onlycurrentPump 1 Current High Warning :This OID indicates the Pump1 current is higher than the warning threshold <Help> This alarm indicates if the pump1 current is high…
1.3.6.1.4.1.20044.72.2.3.1.33.2Scalarpmora14AlmPump2CurrentHighWarningread-onlycurrentPump 2 Current High Warning :This OID indicates the Pump2 current is higher than the warning threshold <Help> This alarm indicates if the pump2 current is high…
1.3.6.1.4.1.20044.72.2.3.1.33.3Scalarpmora14AlmPump1TecWarningread-onlycurrentPump 1 TEC Warning :This OID indicates a transmit laser fail on pump 1 <Help> This alarm indicates if the laser of the pump1 is in fail condition <Condtype> PU…
1.3.6.1.4.1.20044.72.2.3.1.33.4Scalarpmora14AlmPump2TecWarningread-onlycurrentPump 2 TEC Warning :This OID indicates a transmit laser fail on pump 2 <Help> This alarm indicates if the laser of the pump2 is in fail condition <Condtype> PU…
1.3.6.1.4.1.20044.72.2.3.2Nodepmora14AlmLineUrg
1.3.6.1.4.1.20044.72.2.3.2.7Nodepmora14AlmsynthAlm7
1.3.6.1.4.1.20044.72.2.3.2.7.4Scalarpmora14AlmLineHwFailread-onlycurrentLine Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Help> This alarm indicates a failure on the HW Line port <…
1.3.6.1.4.1.20044.72.2.3.2.7.5Scalarpmora14AlmPumpsTxOffread-onlycurrentPumps Laser Shutdown :This OID indicates the power of the pumps are both on <Help> This status indicates if the pumps lasers are both OFF <Condtype> PUMPS_TX_O…
1.3.6.1.4.1.20044.72.2.3.2.7.12Scalarpmora14AlmLineFailread-onlycurrentLine Port Failure :This OID indicates a failure on the line port <Help> This alarm indicates a failure on the Line port <Condtype> LINE_FAIL <Probcause> equipm…
1.3.6.1.4.1.20044.72.2.3.2.32Nodepmora14AlmclientOraAlarms1
1.3.6.1.4.1.20044.72.2.3.2.32.1Scalarpmora14AlmPump1CurrentHighAlarmread-onlycurrentPump 1 Current High Alarm :This OID indicates the Pump1 current is higher than the alarm threshold <Help> This alarm indicates if the pump1 current is higher t…
1.3.6.1.4.1.20044.72.2.3.2.32.2Scalarpmora14AlmPump2CurrentHighAlarmread-onlycurrentPump 2 Current High Alarm :This OID indicates the Pump2 current is higher than the alarm threshold <Help> This alarm indicates if the pump2 current is higher t…
1.3.6.1.4.1.20044.72.2.3.2.32.3Scalarpmora14AlmPump1TecAlarmread-onlycurrentPump 1 TEC Alarm :This OID indicates a transmit laser fail on pump 1 <Help> This alarm indicates if the laser of the pump1 is in fail condition <Condtype> PUMP…
1.3.6.1.4.1.20044.72.2.3.2.32.4Scalarpmora14AlmPump2TecAlarmread-onlycurrentPump 2 TEC Alarm :This OID indicates a transmit laser fail on pump 2 <Help> This alarm indicates if the laser of the pump2 is in fail condition <Condtype> PUMP…
1.3.6.1.4.1.20044.72.2.3.2.72Nodepmora14AlmfiberAlarms
1.3.6.1.4.1.20044.72.2.3.2.72.1Scalarpmora14AlmSBandLossOfSignalread-onlycurrentS Band Loss Of Signal :This OID indicates that a Loss of Signal is detected over the S-Band <Help> This alarm indicates that a Loss of Signal is detected over …
1.3.6.1.4.1.20044.72.2.3.2.72.2Scalarpmora14AlmLowSBandread-onlycurrentLow S Band :This OID indicates that the input power over the S-Band is too low <Help> This alarm indicates that the input power over the S-Band is too low <Con…
1.3.6.1.4.1.20044.72.2.3.2.72.3Scalarpmora14AlmCBandLossOfSignalread-onlycurrentC Band Loss Of Signal :This OID indicates that a Loss of Signal is detected over the C-Band <Help> This alarm indicates that a Loss of Signal is detected over …
1.3.6.1.4.1.20044.72.2.3.2.72.4Scalarpmora14AlmHighBackReflectionread-onlycurrentHigh Back Reflection :This OID indicates that a High Back Reflection ratio is too high <Help> This alarm indicates that a High Back Reflection ratio is too hig…
1.3.6.1.4.1.20044.72.2.3.2.72.5Scalarpmora14AlmLineConnectorUnlockedread-onlycurrentLine Connector Unlocked :This OID indicates the Fonrt panel Line connector is not locked <Help> This alarm indicates the Fonrt panel Line connector is not lock…
1.3.6.1.4.1.20044.72.2.3.2.72.6Scalarpmora14AlmOscFailedread-onlycurrentOsc Failed :This OID indicates that an OSC Loss of Frame is reported by the linked HCS amplifier <Help> This alarm indicates that an OSC Loss of Frame is repor…
1.3.6.1.4.1.20044.72.2.3.2.72.7Scalarpmora14AlmPartialAprSecurityread-onlycurrentPartial APR Security :This OID indicates at least one APR security switch has been disabled <Help> This alarm indicates at least one APR security switch has be…
1.3.6.1.4.1.20044.72.2.3.2.72.8Scalarpmora14AlmStartupLowSBandread-onlycurrentStartup Low S Band :This OID indicates that the input power over the S-Band is too low on startup <Help> This alarm indicates that the input power over the S-B…
1.3.6.1.4.1.20044.72.2.3.2.72.9Scalarpmora14AlmStartupHighBackReflectionread-onlycurrentStartup High Back Reflection :This OID indicates that a High Back Reflection ratio is too high on startup <Help> This alarm indicates that a High Back Reflecti…
1.3.6.1.4.1.20044.72.2.3.3Nodepmora14AlmLineCrit
1.3.6.1.4.1.20044.72.2.3.3.35Nodepmora14Almpump1Alarms
1.3.6.1.4.1.20044.72.2.3.3.35.1Scalarpmora14AlmPump1Shutdownread-onlycurrentPump 1 Laser Shutdown :This OID indicates that the pump 1 is shutdown <Help> This status indicates if the pump1 is shutdown <Condtype> PUMP1_SHUTDOWN <Probcaus…
1.3.6.1.4.1.20044.72.2.3.3.35.2Scalarpmora14AlmPump1TecFailread-onlycurrentPump 1 TEC Fail :This OID indicates that the TEC is in fail condition on pump 1 <Help> This alarm indicates if the TEC of the pump1 is in fail condition <Condt…
1.3.6.1.4.1.20044.72.2.3.3.36Nodepmora14Almpump2Alarms
1.3.6.1.4.1.20044.72.2.3.3.36.1Scalarpmora14AlmPump2Shutdownread-onlycurrentPump 2 Laser Shutdown :This OID indicates that the pump 2 is shutdown <Help> This status indicates if the pump2 is shutdown <Condtype> PUMP2_SHUTDOWN <Probcaus…
1.3.6.1.4.1.20044.72.2.3.3.36.2Scalarpmora14AlmPump2TecFailread-onlycurrentPump 2 TEC Fail :This OID indicates that the TEC is in fail condition on pump 2 <Help> This alarm indicates if the TEC of the pump2 is in fail condition <Condt…
1.3.6.1.4.1.20044.72.3Nodepmora14measures
1.3.6.1.4.1.20044.72.3.1Nodepmora14MesrOther
1.3.6.1.4.1.20044.72.3.1.80Scalarpmora14MesrpmTempMeasread-onlycurrentModule Temperature :This OID gives the temperature of the PM (Temperature =AV/256) (Unit = C)<Help> This measure gives the temperature of the module
1.3.6.1.4.1.20044.72.3.2Nodepmora14MesrClient
1.3.6.1.4.1.20044.72.3.3Nodepmora14MesrLine
1.3.6.1.4.1.20044.72.3.3.64Scalarpmora14Mesrpump1CurrentMeasread-onlycurrentPump 1 Laser Current :This OID gives the Pump1 laser current (Current =AV/10) (Unit = mA) <Help> This measure gives the Pump1 Laser current
1.3.6.1.4.1.20044.72.3.3.65Scalarpmora14Mesrpump1PowerMeasread-onlycurrentPump 1 Tx Power :This OID gives the Pump1 power value (Power =AV/20) (Unit = mW) <Help> This measure gives the Pump1 Power value
1.3.6.1.4.1.20044.72.3.3.66Scalarpmora14Mesrpump1TempMeasread-onlycurrentPump 1 Temperature :This OID gives the Pump1 TEC temperature (Temperature =AV/256) (Unit = C)<Help> This measure gives the Pump1 TEC temperature
1.3.6.1.4.1.20044.72.3.3.67Scalarpmora14Mesrpump1TecCurrentMeasread-onlycurrentPump 1 TEC Current :This OID gives the Pump1 TEC current (Current =AV/10) (Unit = mA) <Help> This measure gives the Pump1 TEC current
1.3.6.1.4.1.20044.72.3.3.68Scalarpmora14Mesrpump2CurrentMeasread-onlycurrentPump 2 Laser Current :This OID gives the Pump2 laser current (Current =AV/10) (Unit = mA) <Help> This measure gives the Pump2 Laser current
1.3.6.1.4.1.20044.72.3.3.69Scalarpmora14Mesrpump2PowerMeasread-onlycurrentPump 2 Tx Power :This OID gives the Pump2 power value (Power =AV/20) (Unit = mW) <Help> This measure gives the Pump2 Power value
1.3.6.1.4.1.20044.72.3.3.70Scalarpmora14Mesrpump2TempMeasread-onlycurrentPump 2 Temperature :This OID gives the Pump2 TEC temperature (Temperature =AV/256) (Unit = C) <Help> This measure gives the Pump2 TEC temperature
1.3.6.1.4.1.20044.72.3.3.71Scalarpmora14Mesrpump2TecCurrentMeasread-onlycurrentPump 2 TEC Current :This OID gives the Pump2 TEC current (Current =AV/10) (Unit = mA) <Help> This measure gives the Pump2 TEC current
1.3.6.1.4.1.20044.72.3.3.72Scalarpmora14MesrtotalPumpsPowerread-onlycurrentTotal Pumps Power :This OID indicates the total pumps power (Power = AV/20) (Unit = mW) <Help> This measure indicates the total pump power
1.3.6.1.4.1.20044.72.3.3.73Scalarpmora14MesrinputCBandPowerread-onlycurrentInput C Band Power :This OID indicates the input power over the C-Band (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure indicates the input power ove…
1.3.6.1.4.1.20044.72.3.3.74Scalarpmora14MesrsBandPowerread-onlycurrentS Band Power :This OID indicates the input power over the S-band (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure indicates the input power over the …
1.3.6.1.4.1.20044.72.3.3.75Scalarpmora14MesrbackReflectionPumpPowerread-onlycurrentBack Reflection Pump Power :This OID indicates the Back Reflection Pump power (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure indicates the Back Ref…
1.3.6.1.4.1.20044.72.3.3.76Scalarpmora14MesrbackReflectionPumpRatioread-onlycurrentBack Reflection Pump Ratio :This OID indicates the Back Relfection Pump ration (Power =(AV-32768)*0,005) (Unit = dB) <Help> This measure indicates the Back Ref…
1.3.6.1.4.1.20044.72.4Nodepmora14counters
1.3.6.1.4.1.20044.72.4.1Nodepmora14CntOther
1.3.6.1.4.1.20044.72.4.2Nodepmora14CntClient
1.3.6.1.4.1.20044.72.4.3Nodepmora14CntLine
1.3.6.1.4.1.20044.72.4.259Scalarpmora14CntCountersResetread-writecurrentCounters Reset:This OID resets and restarts all the counters
1.3.6.1.4.1.20044.72.4.260Scalarpmora14CntCountersStopread-writecurrentCounters stop:This OID stops all the counters
1.3.6.1.4.1.20044.72.6Nodepmora14controlsWrite
1.3.6.1.4.1.20044.72.6.1Nodepmora14CtrlOther
1.3.6.1.4.1.20044.72.6.1.0Nodepmora14Ctrlsynth0
1.3.6.1.4.1.20044.72.6.1.0.1Scalarpmora14CtrlConfLoadread-writecurrentLoad Configuration Tables :When set this enables loading from flash configuration1 into the module.
1.3.6.1.4.1.20044.72.6.1.0.9Scalarpmora14CtrlConfFlashread-writecurrentWrite Configuration Tables :This bit saves the current configuration of the module as configuration in the flash. <Help> This control saves the customer config…
1.3.6.1.4.1.20044.72.6.1.0.13Scalarpmora14CtrlConfClearread-writecurrentClear Configuration Tables :This bit clears the configuration tables from configuration in the flash. <Help> This control restores the default configuration of…
1.3.6.1.4.1.20044.72.6.1.5Nodepmora14CtrlswMgnt
1.3.6.1.4.1.20044.72.6.1.5.2Scalarpmora14CtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the Software. This reset is traffic affecting, and the configuration of Software is reloaded on start…
1.3.6.1.4.1.20044.72.6.1.5.3Scalarpmora14CtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the Software. This reset is not traffic affecting, and the configuration of the Sofwtare remains unch…
1.3.6.1.4.1.20044.72.6.1.16Scalarpmora14CtrlaprModeread-writecurrentAPR Mode :This OID selects the APR Mode <Help> This control initiates the APR Mode
1.3.6.1.4.1.20044.72.6.1.73Nodepmora14CtrlledTest
1.3.6.1.4.1.20044.72.6.1.73.1Scalarpmora14CtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.72.6.1.73.2Scalarpmora14CtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.72.6.1.73.3Scalarpmora14CtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.72.6.1.74Nodepmora14CtrlmaintMode
1.3.6.1.4.1.20044.72.6.1.74.1Scalarpmora14CtrlMaintenanceread-writecurrentPM Maintenance Mode :This OID sets the PM in maintenance mode <Help> This control enables the maintenance mode of the module
1.3.6.1.4.1.20044.72.6.2Nodepmora14CtrlClient
1.3.6.1.4.1.20044.72.6.3Nodepmora14CtrlLine
1.3.6.1.4.1.20044.72.6.3.75Nodepmora14CtrlaprManualRestart
1.3.6.1.4.1.20044.72.6.3.75.1Scalarpmora14CtrlAprManualRestartread-writecurrentAPR Manual Restart :This OID initiates the Restart mechanism to retrieve from the APR state.<Help> This control initiates the Restart mechanism to retrieve fro…
1.3.6.1.4.1.20044.72.7Nodepmora14ri
1.3.6.1.4.1.20044.72.7.1Nodepmora14riTable
1.3.6.1.4.1.20044.72.7.1.2Tablepmora14RinvLineTablenot-accessiblecurrentList of the Lines on the selected module
1.3.6.1.4.1.20044.72.7.1.2.1Rowpmora14RinvLineEntrynot-accessiblecurrentRow definition for the Line table
1.3.6.1.4.1.20044.72.7.1.2.1.1Columnpmora14RinvLineIndexread-onlycurrentIndex for Line table
1.3.6.1.4.1.20044.72.7.1.2.1.2Columnpmora14RinvportLineread-onlycurrentInventory for the Line: This OID contains the inventory for the Line
1.3.6.1.4.1.20044.72.7.2Scalarpmora14RinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.72.7.3Scalarpmora14RinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.72.7.4Scalarpmora14RinvModulePlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.72.7.5Scalarpmora14RinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.72.7.6Scalarpmora14RinvGwPlatformread-onlycurrentGW platform description: This OID contains the description of the gateware platform.
1.3.6.1.4.1.20044.72.9Nodepmora14Config
1.3.6.1.4.1.20044.72.9.1Nodepmora14CfgNoValue
1.3.6.1.4.1.20044.72.9.1.1Nodepmora14tablelineStartup
1.3.6.1.4.1.20044.72.9.1.1.2Scalarpmora14CfgoraModuleCtrlread-writecurrentDefault Settings on the module :This OID configures the default initialisation settings of the Raman module
1.3.6.1.4.1.20044.72.9.1.1.3Scalarpmora14CfgautoRestartDelayread-writecurrentDefault Settings on autorestart delay :This OID configures the default period on the autorestart
1.3.6.1.4.1.20044.72.9.1.1.4Scalarpmora14CfgramanGainread-writecurrentDefault Settings on the Raman Gain :This OID configures the default gain on the Raman module
1.3.6.1.4.1.20044.72.9.1.1.5Scalarpmora14CfgramanModeread-writecurrentDefault Settings on Raman mode :This OID configures the default Raman mode
1.3.6.1.4.1.20044.72.9.1.1.6Scalarpmora14CfgtiltValueread-writecurrentDefault Settings on the tilt value :This OID configures the default tilt on the line amplifier.
1.3.6.1.4.1.20044.72.9.1.1.7Scalarpmora14CfghighBackreflectionThresholdread-writecurrentDefault Settings on the backreflection threshold :This OID configures the default threshold on the backreflection
1.3.6.1.4.1.20044.72.9.1.1.8Scalarpmora14CfgsBandThresholdread-writecurrentDefault Settings on the S band threshold :This OID configures the default threshold on the S band
1.3.6.1.4.1.20044.72.9.1.1.9Scalarpmora14Cfgpump1ManualPowerread-writecurrentDefault Settings on the pump power :This OID configures the default value on the power
1.3.6.1.4.1.20044.72.9.1.1.10Scalarpmora14Cfgpump2ManualPowerread-writecurrentDefault Settings on the pump power :This OID configures the default value on the power
1.3.6.1.4.1.20044.72.9.2Nodepmora14CfgLabels
1.3.6.1.4.1.20044.72.9.2.1Tablepmora14CfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.72.9.2.1.1Rowpmora14CfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.72.9.2.1.1.1Columnpmora14CfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.72.9.2.1.1.3Columnpmora14CfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.72.9.2.2Tablepmora14CfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.72.9.2.2.1Rowpmora14CfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.72.9.2.2.1.1Columnpmora14CfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.72.9.2.2.1.3Columnpmora14CfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.72.9.257Scalarpmora14CfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.72.10Nodepmora14traps
1.3.6.1.4.1.20044.72.10.4Scalarpmora14trapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.72.10.34Notificationpmora14LineTrapCritGoesOncurrentCritical Line default is activated
1.3.6.1.4.1.20044.72.10.35Notificationpmora14LineTrapCritGoesOffcurrentCritical Line default disappeared
1.3.6.1.4.1.20044.72.10.50Notificationpmora14PowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.72.10.51Notificationpmora14PowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared
Type Definitions
NameSyntaxStatusDescription
Pmora14AprModeINTEGER { ora14aproffmode(0), ora14aproscmode(1), ora14aprbrratiomode(2) ora14aprsbandmode(3) ora14aprfullmode(4) }currentDifferent modes on APR
Pmora14LineFiberTypeModeINTEGER { ora14g652mode(0), ora14g655leafmode(1), ora14g655truewavemode(2) ora14g654mode(3) ora14g653mode(4) }currentDifferent modes on APR
Pmora14PumpsModeINTEGER { ora14maxpowermode(0), ora14gaincontrolmode(1), ora14manualcontrolmode(2) }currentDifferent modes on the Raman Module