EKINOPS-Pmotdr-MIB
161 objects
Creation.
Imported Objects
| EKINOPS-MIB | EkiApiState EkiMeasureType EkiMode ekinops EkiOnOff EkiProtocol EkiState EkiSynchroMode |
| SNMPv2-SMI | Counter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20044.95 | IdentitymodulePmotdr | Creation. | ||
| 1.3.6.1.4.1.20044.95.2 | Nodepmotdralarms | |||
| 1.3.6.1.4.1.20044.95.2.1 | NodepmotdrAlmOther | |||
| 1.3.6.1.4.1.20044.95.2.1.1 | NodepmotdrAlmOtherNurg | |||
| 1.3.6.1.4.1.20044.95.2.1.1.2 | NodepmotdrAlmsynthAlm2 | |||
| 1.3.6.1.4.1.20044.95.2.1.1.2.1 | ScalarpmotdrAlmConfTableSave | read-only | current | PM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> infor… |
| 1.3.6.1.4.1.20044.95.2.1.1.2.2 | ScalarpmotdrAlmInvUpload | read-only | current | Inventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> informationalStatus(1000) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.95.2.1.1.2.3 | ScalarpmotdrAlmConfTableLoad | read-only | current | PM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> informationalStat… |
| 1.3.6.1.4.1.20044.95.2.1.1.2.4 | ScalarpmotdrAlmCorrelatOff | read-only | current | Not Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> informationalStatus(1000) <Alarmtype… |
| 1.3.6.1.4.1.20044.95.2.1.2 | NodepmotdrAlmOtherUrg | |||
| 1.3.6.1.4.1.20044.95.2.1.3 | NodepmotdrAlmOtherCrit | |||
| 1.3.6.1.4.1.20044.95.2.1.3.0 | NodepmotdrAlmsynthAlm0 | |||
| 1.3.6.1.4.1.20044.95.2.1.3.0.9 | ScalarpmotdrAlmModGlobFail | read-only | current | Module Failure :This OID is set on detection of a failure originating from the RM <Help> This alarm is set on detection of a failure originating from the equip… |
| 1.3.6.1.4.1.20044.95.2.1.3.0.15 | ScalarpmotdrAlmDefFuseA | read-only | current | Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.95.2.1.3.0.16 | ScalarpmotdrAlmDefFuseB | read-only | current | Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.95.2.2 | NodepmotdrAlmClient | |||
| 1.3.6.1.4.1.20044.95.2.2.1 | NodepmotdrAlmClientNurg | |||
| 1.3.6.1.4.1.20044.95.2.2.2 | NodepmotdrAlmClientUrg | |||
| 1.3.6.1.4.1.20044.95.2.2.3 | NodepmotdrAlmClientCrit | |||
| 1.3.6.1.4.1.20044.95.2.3 | NodepmotdrAlmLine | |||
| 1.3.6.1.4.1.20044.95.2.3.1 | NodepmotdrAlmLineNurg | |||
| 1.3.6.1.4.1.20044.95.2.3.2 | NodepmotdrAlmLineUrg | |||
| 1.3.6.1.4.1.20044.95.2.3.3 | NodepmotdrAlmLineCrit | |||
| 1.3.6.1.4.1.20044.95.2.3.3.24 | TablepmotdrAlmsynthAlmLineTable | not-accessible | current | List of pmotdrAlmsynthAlmLine Article |
| 1.3.6.1.4.1.20044.95.2.3.3.24.1 | RowpmotdrAlmsynthAlmLineEntry | not-accessible | current | Row definition for the pmotdrAlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.95.2.3.3.24.1.1 | ColumnpmotdrAlmsynthAlmLineIndex | read-only | current | Index definition for the pmotdrAlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.95.2.3.3.24.1.2 | ColumnpmotdrAlmLineSfpOtdrAbsentPortn | read-only | current | OTDR Module Absent :This OID indicates that the OTDR SFP is not present. <Help> This alarm indicates if the OTDR SFP is absent <Condtype> LINE_SFP_OTDR_ABSENT … |
| 1.3.6.1.4.1.20044.95.2.3.3.24.1.5 | ColumnpmotdrAlmLineHwFailPortn | read-only | current | Line Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Help> This alarm indicates a failure on line port, most pr… |
| 1.3.6.1.4.1.20044.95.2.3.3.24.1.7 | ColumnpmotdrAlmLineOosPortn | read-only | current | OTDR Module Out Of Service :This OID indicates that the SFP is In Service or Out of Service<Help> This status indicates if the OTDR SFP is in service <Condtype… |
| 1.3.6.1.4.1.20044.95.2.3.3.24.1.10 | ColumnpmotdrAlmLineSfpDdmWarningPortn | read-only | current | : <Condtype> LINE_SFP_DDM_WARNING <Probcause> <Alarmtype> |
| 1.3.6.1.4.1.20044.95.2.3.3.24.1.11 | ColumnpmotdrAlmLineSfpDdmAlmPortn | read-only | current | : <Condtype> LINE_SFP_DDM_ALM <Probcause> <Alarmtype> |
| 1.3.6.1.4.1.20044.95.2.3.3.24.1.13 | ColumnpmotdrAlmLineFailPortn | read-only | current | Line Port Failure :This OID indicates a failure on the line port <Help> This alarm indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipm… |
| 1.3.6.1.4.1.20044.95.2.3.3.40 | TablepmotdrAlmlineAlmDdmTable | not-accessible | current | List of pmotdrAlmlineAlmDdm Article |
| 1.3.6.1.4.1.20044.95.2.3.3.40.1 | RowpmotdrAlmlineAlmDdmEntry | not-accessible | current | Row definition for the pmotdrAlmlineAlmDdm table |
| 1.3.6.1.4.1.20044.95.2.3.3.40.1.1 | ColumnpmotdrAlmlineAlmDdmIndex | read-only | current | Index definition for the pmotdrAlmlineAlmDdm table |
| 1.3.6.1.4.1.20044.95.2.3.3.40.1.4 | ColumnpmotdrAlmTempHighAlarmPortn | read-only | current | OTDR Temp High Alarm :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indicat… |
| 1.3.6.1.4.1.20044.95.2.3.3.40.1.5 | ColumnpmotdrAlmTempLowAlarmPortn | read-only | current | OTDR Temp Low Alarm :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicatin… |
| 1.3.6.1.4.1.20044.95.2.3.3.40.1.10 | ColumnpmotdrAlmOtdrProcessingPortn | read-only | current | OTDR Processing :This OID indicates that the OTDR SFP is processing a fault location<Help> Status indicating that the OTDR is processing the faults locations <… |
| 1.3.6.1.4.1.20044.95.2.3.3.56 | TablepmotdrAlmlineSfpWarnDdmTable | not-accessible | current | List of pmotdrAlmlineSfpWarnDdm Article |
| 1.3.6.1.4.1.20044.95.2.3.3.56.1 | RowpmotdrAlmlineSfpWarnDdmEntry | not-accessible | current | Row definition for the pmotdrAlmlineSfpWarnDdm table |
| 1.3.6.1.4.1.20044.95.2.3.3.56.1.1 | ColumnpmotdrAlmlineSfpWarnDdmIndex | read-only | current | Index definition for the pmotdrAlmlineSfpWarnDdm table |
| 1.3.6.1.4.1.20044.95.2.3.3.56.1.4 | ColumnpmotdrAlmTempHighWarningPortn | read-only | current | OTDR Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning indicating … |
| 1.3.6.1.4.1.20044.95.2.3.3.56.1.5 | ColumnpmotdrAlmTempLowWarningPortn | read-only | current | OTDR Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indicating th… |
| 1.3.6.1.4.1.20044.95.3 | Nodepmotdrmeasures | |||
| 1.3.6.1.4.1.20044.95.3.1 | NodepmotdrMesrOther | |||
| 1.3.6.1.4.1.20044.95.3.2 | NodepmotdrMesrClient | |||
| 1.3.6.1.4.1.20044.95.3.3 | NodepmotdrMesrLine | |||
| 1.3.6.1.4.1.20044.95.3.3.16 | TablepmotdrMesrfaultCounterTable | not-accessible | current | List of pmotdrMesrfaultCounter Article |
| 1.3.6.1.4.1.20044.95.3.3.16.1 | RowpmotdrMesrfaultCounterEntry | not-accessible | current | Row definition for the pmotdrMesrfaultCounter table |
| 1.3.6.1.4.1.20044.95.3.3.16.1.1 | ColumnpmotdrMesrfaultCounterIndex | read-only | current | Index definition for the pmotdrMesrfaultCounter table |
| 1.3.6.1.4.1.20044.95.3.3.16.1.2 | ColumnpmotdrMesrfaultCounterPortn | read-only | current | Fault Counter :This OID gives the number of fault detected (Number = AV_U16) (Unit = Faults) <Help> This measure gives the number of fault detected |
| 1.3.6.1.4.1.20044.95.3.3.20 | TablepmotdrMesrfaultDistanceTable | not-accessible | current | List of pmotdrMesrfaultDistance Article |
| 1.3.6.1.4.1.20044.95.3.3.20.1 | RowpmotdrMesrfaultDistanceEntry | not-accessible | current | Row definition for the pmotdrMesrfaultDistance table |
| 1.3.6.1.4.1.20044.95.3.3.20.1.1 | ColumnpmotdrMesrfaultDistanceIndex | read-only | current | Index definition for the pmotdrMesrfaultDistance table |
| 1.3.6.1.4.1.20044.95.3.3.20.1.2 | ColumnpmotdrMesrfaultDistancePortn | read-only | current | Fault Distance :This OID gives the distance value of the fault detected (Distance = AV_U16*2) (Unit = m) <Help> This measure gives the distance of the fault de… |
| 1.3.6.1.4.1.20044.95.3.3.24 | TablepmotdrMesropticalReturnLossTable | not-accessible | current | List of pmotdrMesropticalReturnLoss Article |
| 1.3.6.1.4.1.20044.95.3.3.24.1 | RowpmotdrMesropticalReturnLossEntry | not-accessible | current | Row definition for the pmotdrMesropticalReturnLoss table |
| 1.3.6.1.4.1.20044.95.3.3.24.1.1 | ColumnpmotdrMesropticalReturnLossIndex | read-only | current | Index definition for the pmotdrMesropticalReturnLoss table |
| 1.3.6.1.4.1.20044.95.3.3.24.1.2 | ColumnpmotdrMesropticalReturnLossPortn | read-only | current | Optical Return Loss :This OID gives the Optical Return Loss value on the fault detected ( Return Loss = AV_U16/4) (Unit = dB) <Help> This measure gives the Opt… |
| 1.3.6.1.4.1.20044.95.3.3.28 | TablepmotdrMesrlineSfpTempTable | not-accessible | current | List of pmotdrMesrlineSfpTemp Article |
| 1.3.6.1.4.1.20044.95.3.3.28.1 | RowpmotdrMesrlineSfpTempEntry | not-accessible | current | Row definition for the pmotdrMesrlineSfpTemp table |
| 1.3.6.1.4.1.20044.95.3.3.28.1.1 | ColumnpmotdrMesrlineSfpTempIndex | read-only | current | Index definition for the pmotdrMesrlineSfpTemp table |
| 1.3.6.1.4.1.20044.95.3.3.28.1.2 | ColumnpmotdrMesrlineSfpTempPortn | read-only | current | Temperature :This OID gives the temperature value of the OTDR SFP (Temperature = AV_S16/256) (Unit = C) <Help> This measure gives the temperature value of the … |
| 1.3.6.1.4.1.20044.95.3.3.32 | TablepmotdrMesrlineTxPowerTable | not-accessible | current | List of pmotdrMesrlineTxPower Article |
| 1.3.6.1.4.1.20044.95.3.3.32.1 | RowpmotdrMesrlineTxPowerEntry | not-accessible | current | Row definition for the pmotdrMesrlineTxPower table |
| 1.3.6.1.4.1.20044.95.3.3.32.1.1 | ColumnpmotdrMesrlineTxPowerIndex | read-only | current | Index definition for the pmotdrMesrlineTxPower table |
| 1.3.6.1.4.1.20044.95.3.3.32.1.2 | ColumnpmotdrMesrlineTxPowerPortn | read-only | current | Output Power :This OID gives the output power value of the OTDR SFP (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the output power value o… |
| 1.3.6.1.4.1.20044.95.3.3.36 | TablepmotdrMesrlineRxPowerTable | not-accessible | current | List of pmotdrMesrlineRxPower Article |
| 1.3.6.1.4.1.20044.95.3.3.36.1 | RowpmotdrMesrlineRxPowerEntry | not-accessible | current | Row definition for the pmotdrMesrlineRxPower table |
| 1.3.6.1.4.1.20044.95.3.3.36.1.1 | ColumnpmotdrMesrlineRxPowerIndex | read-only | current | Index definition for the pmotdrMesrlineRxPower table |
| 1.3.6.1.4.1.20044.95.3.3.36.1.2 | ColumnpmotdrMesrlineRxPowerPortn | read-only | current | Input Power :This OID gives the intput power value of the OTDR SFP (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the intput power value of… |
| 1.3.6.1.4.1.20044.95.6 | NodepmotdrcontrolsWrite | |||
| 1.3.6.1.4.1.20044.95.6.1 | NodepmotdrCtrlOther | |||
| 1.3.6.1.4.1.20044.95.6.1.1 | NodepmotdrCtrlconfMgnt1 | |||
| 1.3.6.1.4.1.20044.95.6.1.1.1 | ScalarpmotdrCtrlConf1Load1 | read-write | current | Load Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM. |
| 1.3.6.1.4.1.20044.95.6.1.1.2 | ScalarpmotdrCtrlConf2Load1 | read-write | current | Load Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM. |
| 1.3.6.1.4.1.20044.95.6.1.1.10 | ScalarpmotdrCtrlConf2Flash1 | read-write | current | Write Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura… |
| 1.3.6.1.4.1.20044.95.6.1.1.14 | ScalarpmotdrCtrlConf2Clear1 | read-write | current | Clear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o… |
| 1.3.6.1.4.1.20044.95.6.1.4 | NodepmotdrCtrlsynth4 | |||
| 1.3.6.1.4.1.20044.95.6.1.4.1 | ScalarpmotdrCtrlCorrelatOn | read-write | current | Enable Alarm Correlation :This OID enables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.95.6.1.4.2 | ScalarpmotdrCtrlCorrelatOff | read-write | current | Disable Alarm Correlation :This OID disables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.95.6.1.5 | NodepmotdrCtrlswMgnt | |||
| 1.3.6.1.4.1.20044.95.6.1.5.2 | ScalarpmotdrCtrlColdReset | read-write | current | PM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> … |
| 1.3.6.1.4.1.20044.95.6.1.5.3 | ScalarpmotdrCtrlWarmReset | read-write | current | PM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th… |
| 1.3.6.1.4.1.20044.95.6.1.5.5 | ScalarpmotdrCtrlLoadSwBank1 | read-write | current | Set Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW… |
| 1.3.6.1.4.1.20044.95.6.1.5.6 | ScalarpmotdrCtrlLoadSwBank2 | read-write | current | Set Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S… |
| 1.3.6.1.4.1.20044.95.6.1.6 | NodepmotdrCtrlgwMgnt | |||
| 1.3.6.1.4.1.20044.95.6.1.6.1 | ScalarpmotdrCtrlCurrentGwReset | read-write | current | Active Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting. |
| 1.3.6.1.4.1.20044.95.6.1.6.5 | ScalarpmotdrCtrlLoadGwBank1 | read-write | current | Set Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.95.6.1.6.6 | ScalarpmotdrCtrlLoadGwBank2 | read-write | current | Set Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.95.6.1.6.7 | ScalarpmotdrCtrlLoadGwBank3 | read-write | current | Set Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.95.6.1.6.8 | ScalarpmotdrCtrlLoadGwBank4 | read-write | current | Set Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.95.6.1.72 | NodepmotdrCtrlledTest | |||
| 1.3.6.1.4.1.20044.95.6.1.72.1 | ScalarpmotdrCtrlGreenLed | read-write | current | Green Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green |
| 1.3.6.1.4.1.20044.95.6.1.72.2 | ScalarpmotdrCtrlRedLed | read-write | current | Red Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red |
| 1.3.6.1.4.1.20044.95.6.1.72.3 | ScalarpmotdrCtrlLedOff | read-write | current | Leds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF |
| 1.3.6.1.4.1.20044.95.6.2 | NodepmotdrCtrlClient | |||
| 1.3.6.1.4.1.20044.95.6.3 | NodepmotdrCtrlLine | |||
| 1.3.6.1.4.1.20044.95.6.3.16 | TablepmotdrCtrlotdrProcessingTable | not-accessible | current | List of pmotdrCtrlotdrProcessing Article |
| 1.3.6.1.4.1.20044.95.6.3.16.1 | RowpmotdrCtrlotdrProcessingEntry | not-accessible | current | Row definition for the pmotdrCtrlotdrProcessing table |
| 1.3.6.1.4.1.20044.95.6.3.16.1.1 | ColumnpmotdrCtrlotdrProcessingIndex | read-only | current | Index definition for the pmotdrCtrlotdrProcessing table |
| 1.3.6.1.4.1.20044.95.6.3.16.1.2 | ColumnpmotdrCtrlotdrProcessingPortn | read-write | current | Start Processing :This OID starts the fault detection process on the OTDR <Help> This control initiates the fault detection process on the OTDR |
| 1.3.6.1.4.1.20044.95.7 | Nodepmotdrri | |||
| 1.3.6.1.4.1.20044.95.7.1 | NodepmotdrriTable | |||
| 1.3.6.1.4.1.20044.95.7.1.2 | TablepmotdrRinvLineTable | not-accessible | current | List of the SFPs on the selected module |
| 1.3.6.1.4.1.20044.95.7.1.2.1 | RowpmotdrRinvLineEntry | not-accessible | current | Row definition for the SFP table |
| 1.3.6.1.4.1.20044.95.7.1.2.1.1 | ColumnpmotdrRinvLineIndex | read-only | current | Index for SFP table |
| 1.3.6.1.4.1.20044.95.7.1.2.1.2 | ColumnpmotdrRinvxfpLine | read-only | current | Inventory for the XFP: This OID contains the inventory for the XFP |
| 1.3.6.1.4.1.20044.95.7.2 | ScalarpmotdrRinvReloadInventory | read-write | current | Reload the inventory: This OID triggers an inventory reload. |
| 1.3.6.1.4.1.20044.95.7.3 | ScalarpmotdrRinvHwPlatform | read-only | current | HW platform description: This OID contains the description of the Hardware platform. |
| 1.3.6.1.4.1.20044.95.7.4 | ScalarpmotdrRinvModulePlatform | read-only | current | Module platform description: This OID contains the description of the Module. |
| 1.3.6.1.4.1.20044.95.7.5 | ScalarpmotdrRinvSwPlatform | read-only | current | SW platform description: This OID contains the description of the Software platform. |
| 1.3.6.1.4.1.20044.95.7.6 | ScalarpmotdrRinvGwPlatform | read-only | current | GW platform description: This OID contains the description of the Gateware platform. |
| 1.3.6.1.4.1.20044.95.8 | Nodepmotdrdownload | |||
| 1.3.6.1.4.1.20044.95.8.1 | NodepmotdrDwlOther | |||
| 1.3.6.1.4.1.20044.95.8.1.0 | NodepmotdrDwlrestartProcess | |||
| 1.3.6.1.4.1.20044.95.8.1.0.1 | ScalarpmotdrDwlWarmRestartProcessed | read-only | current | Warm Restart :This OID indicates that the module last restart was a Warm RESTART |
| 1.3.6.1.4.1.20044.95.8.1.0.2 | ScalarpmotdrDwlColdRestartProcessed | read-only | current | Cold Restart :This OID indicates that the module last restart was a Cold RESTART |
| 1.3.6.1.4.1.20044.95.8.1.1 | NodepmotdrDwlswBanksUsed | |||
| 1.3.6.1.4.1.20044.95.8.1.1.1 | ScalarpmotdrDwlSwBank1Used | read-only | current | SW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.95.8.1.1.2 | ScalarpmotdrDwlSwBank2Used | read-only | current | SW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby |
| 1.3.6.1.4.1.20044.95.8.1.1.5 | ScalarpmotdrDwlSwBank1Notempty | read-only | current | SW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package |
| 1.3.6.1.4.1.20044.95.8.1.1.6 | ScalarpmotdrDwlSwBank2Notempty | read-only | current | SW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package |
| 1.3.6.1.4.1.20044.95.8.1.2 | NodepmotdrDwlgwBanksUsed | |||
| 1.3.6.1.4.1.20044.95.8.1.2.1 | ScalarpmotdrDwlGwBank1Used | read-only | current | GW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.95.8.1.2.2 | ScalarpmotdrDwlGwBank2Used | read-only | current | GW bank 2 active :This OID indicates the module is working on GW bank 2 |
| 1.3.6.1.4.1.20044.95.8.1.2.3 | ScalarpmotdrDwlGwBank3Used | read-only | current | GW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby |
| 1.3.6.1.4.1.20044.95.8.1.2.4 | ScalarpmotdrDwlGwBank4Used | read-only | current | GW bank 4 active :This OID indicates the module is working on GW bank 4 |
| 1.3.6.1.4.1.20044.95.8.1.2.5 | ScalarpmotdrDwlGwBank1Notempty | read-only | current | GW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package |
| 1.3.6.1.4.1.20044.95.8.1.2.6 | ScalarpmotdrDwlGwBank2Notempty | read-only | current | GW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2 |
| 1.3.6.1.4.1.20044.95.8.1.2.7 | ScalarpmotdrDwlGwBank3Notempty | read-only | current | GW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package |
| 1.3.6.1.4.1.20044.95.8.1.2.8 | ScalarpmotdrDwlGwBank4Notempty | read-only | current | GW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4 |
| 1.3.6.1.4.1.20044.95.8.2 | NodepmotdrDwlClient | |||
| 1.3.6.1.4.1.20044.95.8.3 | NodepmotdrDwlLine | |||
| 1.3.6.1.4.1.20044.95.9 | NodepmotdrConfig | |||
| 1.3.6.1.4.1.20044.95.9.1 | NodepmotdrCfgStartup | |||
| 1.3.6.1.4.1.20044.95.9.1.1 | TablepmotdrCfgLinexr1StartupTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.95.9.1.1.1 | RowpmotdrCfgLinexr1StartupEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.95.9.1.1.1.1 | ColumnpmotdrCfgLinexr1StartupIndex | read-only | current | Index definition for the linexr1Startup table |
| 1.3.6.1.4.1.20044.95.9.1.1.1.3 | ColumnpmotdrCfgSfpModePortn | read-write | current | Default mode on the SFP :This register configures the default initialisation settings on the SFP |
| 1.3.6.1.4.1.20044.95.9.1.1.1.4 | ColumnpmotdrCfgSfpPeriodPortn | read-write | current | Default period on the SFP :This register configures the default initialisation settings of the launching period of the SFP |
| 1.3.6.1.4.1.20044.95.9.1.1.1.6 | ColumnpmotdrCfgLosInputThresholdPortn | read-write | current | Default threshold setting on the SFP :This register configures the default initialisation settings of the input threshold |
| 1.3.6.1.4.1.20044.95.9.2 | NodepmotdrCfgLabels | |||
| 1.3.6.1.4.1.20044.95.9.2.1 | TablepmotdrCfgLabelclientTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.95.9.2.1.1 | RowpmotdrCfgLabelclientEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.95.9.2.1.1.1 | ColumnpmotdrCfgLabelclientIndex | read-only | current | Index definition for the labelclient table |
| 1.3.6.1.4.1.20044.95.9.2.1.1.3 | ColumnpmotdrCfgLabelclientPortn | read-write | current | Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. |
| 1.3.6.1.4.1.20044.95.9.2.2 | TablepmotdrCfgLabellineTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.95.9.2.2.1 | RowpmotdrCfgLabellineEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.95.9.2.2.1.1 | ColumnpmotdrCfgLabellineIndex | read-only | current | Index definition for the labelline table |
| 1.3.6.1.4.1.20044.95.9.2.2.1.3 | ColumnpmotdrCfgLabellinePortn | read-write | current | Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. |
| 1.3.6.1.4.1.20044.95.9.257 | ScalarpmotdrCfgWriteConfiguration | read-write | current | Write configuration to module:This OID writes the complete configuration to the module |
| 1.3.6.1.4.1.20044.95.10 | Nodepmotdrtraps | |||
| 1.3.6.1.4.1.20044.95.10.2 | ScalarpmotdrtrapPortNumber | read-only | current | Last port which generates a trap |
| 1.3.6.1.4.1.20044.95.10.3 | ScalarpmotdrtrapLineNumber | read-only | current | Last Line which generates a trap |
| 1.3.6.1.4.1.20044.95.10.4 | ScalarpmotdrtrapBoardNumber | read-only | current | Last module which generates a trap |
| 1.3.6.1.4.1.20044.95.10.34 | NotificationpmotdrLineTrapCritGoesOn | current | Critical Line default is activated | |
| 1.3.6.1.4.1.20044.95.10.35 | NotificationpmotdrLineTrapCritGoesOff | current | Critical Line default disappeared | |
| 1.3.6.1.4.1.20044.95.10.50 | NotificationpmotdrPowerTrapUrgentGoesOn | current | Urgent power supply default is activated | |
| 1.3.6.1.4.1.20044.95.10.51 | NotificationpmotdrPowerTrapUrgentGoesOff | current | Urgent power supply default disappeared |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| PmotdrMode | INTEGER { manual(0), auto(1) } | current | Different modes on the OTDR SFP |