EKINOPS-Pmotdr-MIB

161 objects
Creation.
OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.95IdentitymodulePmotdrCreation.
1.3.6.1.4.1.20044.95.2Nodepmotdralarms
1.3.6.1.4.1.20044.95.2.1NodepmotdrAlmOther
1.3.6.1.4.1.20044.95.2.1.1NodepmotdrAlmOtherNurg
1.3.6.1.4.1.20044.95.2.1.1.2NodepmotdrAlmsynthAlm2
1.3.6.1.4.1.20044.95.2.1.1.2.1ScalarpmotdrAlmConfTableSaveread-onlycurrentPM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> infor…
1.3.6.1.4.1.20044.95.2.1.1.2.2ScalarpmotdrAlmInvUploadread-onlycurrentInventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> informationalStatus(1000) <Alarmtype> ot…
1.3.6.1.4.1.20044.95.2.1.1.2.3ScalarpmotdrAlmConfTableLoadread-onlycurrentPM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> informationalStat…
1.3.6.1.4.1.20044.95.2.1.1.2.4ScalarpmotdrAlmCorrelatOffread-onlycurrentNot Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> informationalStatus(1000) <Alarmtype…
1.3.6.1.4.1.20044.95.2.1.2NodepmotdrAlmOtherUrg
1.3.6.1.4.1.20044.95.2.1.3NodepmotdrAlmOtherCrit
1.3.6.1.4.1.20044.95.2.1.3.0NodepmotdrAlmsynthAlm0
1.3.6.1.4.1.20044.95.2.1.3.0.9ScalarpmotdrAlmModGlobFailread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the RM <Help> This alarm is set on detection of a failure originating from the equip…
1.3.6.1.4.1.20044.95.2.1.3.0.15ScalarpmotdrAlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.95.2.1.3.0.16ScalarpmotdrAlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.95.2.2NodepmotdrAlmClient
1.3.6.1.4.1.20044.95.2.2.1NodepmotdrAlmClientNurg
1.3.6.1.4.1.20044.95.2.2.2NodepmotdrAlmClientUrg
1.3.6.1.4.1.20044.95.2.2.3NodepmotdrAlmClientCrit
1.3.6.1.4.1.20044.95.2.3NodepmotdrAlmLine
1.3.6.1.4.1.20044.95.2.3.1NodepmotdrAlmLineNurg
1.3.6.1.4.1.20044.95.2.3.2NodepmotdrAlmLineUrg
1.3.6.1.4.1.20044.95.2.3.3NodepmotdrAlmLineCrit
1.3.6.1.4.1.20044.95.2.3.3.24TablepmotdrAlmsynthAlmLineTablenot-accessiblecurrentList of pmotdrAlmsynthAlmLine Article
1.3.6.1.4.1.20044.95.2.3.3.24.1RowpmotdrAlmsynthAlmLineEntrynot-accessiblecurrentRow definition for the pmotdrAlmsynthAlmLine table
1.3.6.1.4.1.20044.95.2.3.3.24.1.1ColumnpmotdrAlmsynthAlmLineIndexread-onlycurrentIndex definition for the pmotdrAlmsynthAlmLine table
1.3.6.1.4.1.20044.95.2.3.3.24.1.2ColumnpmotdrAlmLineSfpOtdrAbsentPortnread-onlycurrentOTDR Module Absent :This OID indicates that the OTDR SFP is not present. <Help> This alarm indicates if the OTDR SFP is absent <Condtype> LINE_SFP_OTDR_ABSENT …
1.3.6.1.4.1.20044.95.2.3.3.24.1.5ColumnpmotdrAlmLineHwFailPortnread-onlycurrentLine Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Help> This alarm indicates a failure on line port, most pr…
1.3.6.1.4.1.20044.95.2.3.3.24.1.7ColumnpmotdrAlmLineOosPortnread-onlycurrentOTDR Module Out Of Service :This OID indicates that the SFP is In Service or Out of Service<Help> This status indicates if the OTDR SFP is in service <Condtype…
1.3.6.1.4.1.20044.95.2.3.3.24.1.10ColumnpmotdrAlmLineSfpDdmWarningPortnread-onlycurrent: <Condtype> LINE_SFP_DDM_WARNING <Probcause> <Alarmtype>
1.3.6.1.4.1.20044.95.2.3.3.24.1.11ColumnpmotdrAlmLineSfpDdmAlmPortnread-onlycurrent: <Condtype> LINE_SFP_DDM_ALM <Probcause> <Alarmtype>
1.3.6.1.4.1.20044.95.2.3.3.24.1.13ColumnpmotdrAlmLineFailPortnread-onlycurrentLine Port Failure :This OID indicates a failure on the line port <Help> This alarm indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipm…
1.3.6.1.4.1.20044.95.2.3.3.40TablepmotdrAlmlineAlmDdmTablenot-accessiblecurrentList of pmotdrAlmlineAlmDdm Article
1.3.6.1.4.1.20044.95.2.3.3.40.1RowpmotdrAlmlineAlmDdmEntrynot-accessiblecurrentRow definition for the pmotdrAlmlineAlmDdm table
1.3.6.1.4.1.20044.95.2.3.3.40.1.1ColumnpmotdrAlmlineAlmDdmIndexread-onlycurrentIndex definition for the pmotdrAlmlineAlmDdm table
1.3.6.1.4.1.20044.95.2.3.3.40.1.4ColumnpmotdrAlmTempHighAlarmPortnread-onlycurrentOTDR Temp High Alarm :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indicat…
1.3.6.1.4.1.20044.95.2.3.3.40.1.5ColumnpmotdrAlmTempLowAlarmPortnread-onlycurrentOTDR Temp Low Alarm :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicatin…
1.3.6.1.4.1.20044.95.2.3.3.40.1.10ColumnpmotdrAlmOtdrProcessingPortnread-onlycurrentOTDR Processing :This OID indicates that the OTDR SFP is processing a fault location<Help> Status indicating that the OTDR is processing the faults locations <…
1.3.6.1.4.1.20044.95.2.3.3.56TablepmotdrAlmlineSfpWarnDdmTablenot-accessiblecurrentList of pmotdrAlmlineSfpWarnDdm Article
1.3.6.1.4.1.20044.95.2.3.3.56.1RowpmotdrAlmlineSfpWarnDdmEntrynot-accessiblecurrentRow definition for the pmotdrAlmlineSfpWarnDdm table
1.3.6.1.4.1.20044.95.2.3.3.56.1.1ColumnpmotdrAlmlineSfpWarnDdmIndexread-onlycurrentIndex definition for the pmotdrAlmlineSfpWarnDdm table
1.3.6.1.4.1.20044.95.2.3.3.56.1.4ColumnpmotdrAlmTempHighWarningPortnread-onlycurrentOTDR Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning indicating …
1.3.6.1.4.1.20044.95.2.3.3.56.1.5ColumnpmotdrAlmTempLowWarningPortnread-onlycurrentOTDR Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indicating th…
1.3.6.1.4.1.20044.95.3Nodepmotdrmeasures
1.3.6.1.4.1.20044.95.3.1NodepmotdrMesrOther
1.3.6.1.4.1.20044.95.3.2NodepmotdrMesrClient
1.3.6.1.4.1.20044.95.3.3NodepmotdrMesrLine
1.3.6.1.4.1.20044.95.3.3.16TablepmotdrMesrfaultCounterTablenot-accessiblecurrentList of pmotdrMesrfaultCounter Article
1.3.6.1.4.1.20044.95.3.3.16.1RowpmotdrMesrfaultCounterEntrynot-accessiblecurrentRow definition for the pmotdrMesrfaultCounter table
1.3.6.1.4.1.20044.95.3.3.16.1.1ColumnpmotdrMesrfaultCounterIndexread-onlycurrentIndex definition for the pmotdrMesrfaultCounter table
1.3.6.1.4.1.20044.95.3.3.16.1.2ColumnpmotdrMesrfaultCounterPortnread-onlycurrentFault Counter :This OID gives the number of fault detected (Number = AV_U16) (Unit = Faults) <Help> This measure gives the number of fault detected
1.3.6.1.4.1.20044.95.3.3.20TablepmotdrMesrfaultDistanceTablenot-accessiblecurrentList of pmotdrMesrfaultDistance Article
1.3.6.1.4.1.20044.95.3.3.20.1RowpmotdrMesrfaultDistanceEntrynot-accessiblecurrentRow definition for the pmotdrMesrfaultDistance table
1.3.6.1.4.1.20044.95.3.3.20.1.1ColumnpmotdrMesrfaultDistanceIndexread-onlycurrentIndex definition for the pmotdrMesrfaultDistance table
1.3.6.1.4.1.20044.95.3.3.20.1.2ColumnpmotdrMesrfaultDistancePortnread-onlycurrentFault Distance :This OID gives the distance value of the fault detected (Distance = AV_U16*2) (Unit = m) <Help> This measure gives the distance of the fault de…
1.3.6.1.4.1.20044.95.3.3.24TablepmotdrMesropticalReturnLossTablenot-accessiblecurrentList of pmotdrMesropticalReturnLoss Article
1.3.6.1.4.1.20044.95.3.3.24.1RowpmotdrMesropticalReturnLossEntrynot-accessiblecurrentRow definition for the pmotdrMesropticalReturnLoss table
1.3.6.1.4.1.20044.95.3.3.24.1.1ColumnpmotdrMesropticalReturnLossIndexread-onlycurrentIndex definition for the pmotdrMesropticalReturnLoss table
1.3.6.1.4.1.20044.95.3.3.24.1.2ColumnpmotdrMesropticalReturnLossPortnread-onlycurrentOptical Return Loss :This OID gives the Optical Return Loss value on the fault detected ( Return Loss = AV_U16/4) (Unit = dB) <Help> This measure gives the Opt…
1.3.6.1.4.1.20044.95.3.3.28TablepmotdrMesrlineSfpTempTablenot-accessiblecurrentList of pmotdrMesrlineSfpTemp Article
1.3.6.1.4.1.20044.95.3.3.28.1RowpmotdrMesrlineSfpTempEntrynot-accessiblecurrentRow definition for the pmotdrMesrlineSfpTemp table
1.3.6.1.4.1.20044.95.3.3.28.1.1ColumnpmotdrMesrlineSfpTempIndexread-onlycurrentIndex definition for the pmotdrMesrlineSfpTemp table
1.3.6.1.4.1.20044.95.3.3.28.1.2ColumnpmotdrMesrlineSfpTempPortnread-onlycurrentTemperature :This OID gives the temperature value of the OTDR SFP (Temperature = AV_S16/256) (Unit = C) <Help> This measure gives the temperature value of the …
1.3.6.1.4.1.20044.95.3.3.32TablepmotdrMesrlineTxPowerTablenot-accessiblecurrentList of pmotdrMesrlineTxPower Article
1.3.6.1.4.1.20044.95.3.3.32.1RowpmotdrMesrlineTxPowerEntrynot-accessiblecurrentRow definition for the pmotdrMesrlineTxPower table
1.3.6.1.4.1.20044.95.3.3.32.1.1ColumnpmotdrMesrlineTxPowerIndexread-onlycurrentIndex definition for the pmotdrMesrlineTxPower table
1.3.6.1.4.1.20044.95.3.3.32.1.2ColumnpmotdrMesrlineTxPowerPortnread-onlycurrentOutput Power :This OID gives the output power value of the OTDR SFP (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the output power value o…
1.3.6.1.4.1.20044.95.3.3.36TablepmotdrMesrlineRxPowerTablenot-accessiblecurrentList of pmotdrMesrlineRxPower Article
1.3.6.1.4.1.20044.95.3.3.36.1RowpmotdrMesrlineRxPowerEntrynot-accessiblecurrentRow definition for the pmotdrMesrlineRxPower table
1.3.6.1.4.1.20044.95.3.3.36.1.1ColumnpmotdrMesrlineRxPowerIndexread-onlycurrentIndex definition for the pmotdrMesrlineRxPower table
1.3.6.1.4.1.20044.95.3.3.36.1.2ColumnpmotdrMesrlineRxPowerPortnread-onlycurrentInput Power :This OID gives the intput power value of the OTDR SFP (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the intput power value of…
1.3.6.1.4.1.20044.95.6NodepmotdrcontrolsWrite
1.3.6.1.4.1.20044.95.6.1NodepmotdrCtrlOther
1.3.6.1.4.1.20044.95.6.1.1NodepmotdrCtrlconfMgnt1
1.3.6.1.4.1.20044.95.6.1.1.1ScalarpmotdrCtrlConf1Load1read-writecurrentLoad Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM.
1.3.6.1.4.1.20044.95.6.1.1.2ScalarpmotdrCtrlConf2Load1read-writecurrentLoad Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM.
1.3.6.1.4.1.20044.95.6.1.1.10ScalarpmotdrCtrlConf2Flash1read-writecurrentWrite Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura…
1.3.6.1.4.1.20044.95.6.1.1.14ScalarpmotdrCtrlConf2Clear1read-writecurrentClear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o…
1.3.6.1.4.1.20044.95.6.1.4NodepmotdrCtrlsynth4
1.3.6.1.4.1.20044.95.6.1.4.1ScalarpmotdrCtrlCorrelatOnread-writecurrentEnable Alarm Correlation :This OID enables the alarm correlation in the PM.
1.3.6.1.4.1.20044.95.6.1.4.2ScalarpmotdrCtrlCorrelatOffread-writecurrentDisable Alarm Correlation :This OID disables the alarm correlation in the PM.
1.3.6.1.4.1.20044.95.6.1.5NodepmotdrCtrlswMgnt
1.3.6.1.4.1.20044.95.6.1.5.2ScalarpmotdrCtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> …
1.3.6.1.4.1.20044.95.6.1.5.3ScalarpmotdrCtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th…
1.3.6.1.4.1.20044.95.6.1.5.5ScalarpmotdrCtrlLoadSwBank1read-writecurrentSet Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW…
1.3.6.1.4.1.20044.95.6.1.5.6ScalarpmotdrCtrlLoadSwBank2read-writecurrentSet Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S…
1.3.6.1.4.1.20044.95.6.1.6NodepmotdrCtrlgwMgnt
1.3.6.1.4.1.20044.95.6.1.6.1ScalarpmotdrCtrlCurrentGwResetread-writecurrentActive Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting.
1.3.6.1.4.1.20044.95.6.1.6.5ScalarpmotdrCtrlLoadGwBank1read-writecurrentSet Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.95.6.1.6.6ScalarpmotdrCtrlLoadGwBank2read-writecurrentSet Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.95.6.1.6.7ScalarpmotdrCtrlLoadGwBank3read-writecurrentSet Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.95.6.1.6.8ScalarpmotdrCtrlLoadGwBank4read-writecurrentSet Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.95.6.1.72NodepmotdrCtrlledTest
1.3.6.1.4.1.20044.95.6.1.72.1ScalarpmotdrCtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.95.6.1.72.2ScalarpmotdrCtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.95.6.1.72.3ScalarpmotdrCtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.95.6.2NodepmotdrCtrlClient
1.3.6.1.4.1.20044.95.6.3NodepmotdrCtrlLine
1.3.6.1.4.1.20044.95.6.3.16TablepmotdrCtrlotdrProcessingTablenot-accessiblecurrentList of pmotdrCtrlotdrProcessing Article
1.3.6.1.4.1.20044.95.6.3.16.1RowpmotdrCtrlotdrProcessingEntrynot-accessiblecurrentRow definition for the pmotdrCtrlotdrProcessing table
1.3.6.1.4.1.20044.95.6.3.16.1.1ColumnpmotdrCtrlotdrProcessingIndexread-onlycurrentIndex definition for the pmotdrCtrlotdrProcessing table
1.3.6.1.4.1.20044.95.6.3.16.1.2ColumnpmotdrCtrlotdrProcessingPortnread-writecurrentStart Processing :This OID starts the fault detection process on the OTDR <Help> This control initiates the fault detection process on the OTDR
1.3.6.1.4.1.20044.95.7Nodepmotdrri
1.3.6.1.4.1.20044.95.7.1NodepmotdrriTable
1.3.6.1.4.1.20044.95.7.1.2TablepmotdrRinvLineTablenot-accessiblecurrentList of the SFPs on the selected module
1.3.6.1.4.1.20044.95.7.1.2.1RowpmotdrRinvLineEntrynot-accessiblecurrentRow definition for the SFP table
1.3.6.1.4.1.20044.95.7.1.2.1.1ColumnpmotdrRinvLineIndexread-onlycurrentIndex for SFP table
1.3.6.1.4.1.20044.95.7.1.2.1.2ColumnpmotdrRinvxfpLineread-onlycurrentInventory for the XFP: This OID contains the inventory for the XFP
1.3.6.1.4.1.20044.95.7.2ScalarpmotdrRinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.95.7.3ScalarpmotdrRinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.95.7.4ScalarpmotdrRinvModulePlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.95.7.5ScalarpmotdrRinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.95.7.6ScalarpmotdrRinvGwPlatformread-onlycurrentGW platform description: This OID contains the description of the Gateware platform.
1.3.6.1.4.1.20044.95.8Nodepmotdrdownload
1.3.6.1.4.1.20044.95.8.1NodepmotdrDwlOther
1.3.6.1.4.1.20044.95.8.1.0NodepmotdrDwlrestartProcess
1.3.6.1.4.1.20044.95.8.1.0.1ScalarpmotdrDwlWarmRestartProcessedread-onlycurrentWarm Restart :This OID indicates that the module last restart was a Warm RESTART
1.3.6.1.4.1.20044.95.8.1.0.2ScalarpmotdrDwlColdRestartProcessedread-onlycurrentCold Restart :This OID indicates that the module last restart was a Cold RESTART
1.3.6.1.4.1.20044.95.8.1.1NodepmotdrDwlswBanksUsed
1.3.6.1.4.1.20044.95.8.1.1.1ScalarpmotdrDwlSwBank1Usedread-onlycurrentSW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby
1.3.6.1.4.1.20044.95.8.1.1.2ScalarpmotdrDwlSwBank2Usedread-onlycurrentSW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby
1.3.6.1.4.1.20044.95.8.1.1.5ScalarpmotdrDwlSwBank1Notemptyread-onlycurrentSW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package
1.3.6.1.4.1.20044.95.8.1.1.6ScalarpmotdrDwlSwBank2Notemptyread-onlycurrentSW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package
1.3.6.1.4.1.20044.95.8.1.2NodepmotdrDwlgwBanksUsed
1.3.6.1.4.1.20044.95.8.1.2.1ScalarpmotdrDwlGwBank1Usedread-onlycurrentGW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby
1.3.6.1.4.1.20044.95.8.1.2.2ScalarpmotdrDwlGwBank2Usedread-onlycurrentGW bank 2 active :This OID indicates the module is working on GW bank 2
1.3.6.1.4.1.20044.95.8.1.2.3ScalarpmotdrDwlGwBank3Usedread-onlycurrentGW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby
1.3.6.1.4.1.20044.95.8.1.2.4ScalarpmotdrDwlGwBank4Usedread-onlycurrentGW bank 4 active :This OID indicates the module is working on GW bank 4
1.3.6.1.4.1.20044.95.8.1.2.5ScalarpmotdrDwlGwBank1Notemptyread-onlycurrentGW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package
1.3.6.1.4.1.20044.95.8.1.2.6ScalarpmotdrDwlGwBank2Notemptyread-onlycurrentGW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2
1.3.6.1.4.1.20044.95.8.1.2.7ScalarpmotdrDwlGwBank3Notemptyread-onlycurrentGW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package
1.3.6.1.4.1.20044.95.8.1.2.8ScalarpmotdrDwlGwBank4Notemptyread-onlycurrentGW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4
1.3.6.1.4.1.20044.95.8.2NodepmotdrDwlClient
1.3.6.1.4.1.20044.95.8.3NodepmotdrDwlLine
1.3.6.1.4.1.20044.95.9NodepmotdrConfig
1.3.6.1.4.1.20044.95.9.1NodepmotdrCfgStartup
1.3.6.1.4.1.20044.95.9.1.1TablepmotdrCfgLinexr1StartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.95.9.1.1.1RowpmotdrCfgLinexr1StartupEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.95.9.1.1.1.1ColumnpmotdrCfgLinexr1StartupIndexread-onlycurrentIndex definition for the linexr1Startup table
1.3.6.1.4.1.20044.95.9.1.1.1.3ColumnpmotdrCfgSfpModePortnread-writecurrentDefault mode on the SFP :This register configures the default initialisation settings on the SFP
1.3.6.1.4.1.20044.95.9.1.1.1.4ColumnpmotdrCfgSfpPeriodPortnread-writecurrentDefault period on the SFP :This register configures the default initialisation settings of the launching period of the SFP
1.3.6.1.4.1.20044.95.9.1.1.1.6ColumnpmotdrCfgLosInputThresholdPortnread-writecurrentDefault threshold setting on the SFP :This register configures the default initialisation settings of the input threshold
1.3.6.1.4.1.20044.95.9.2NodepmotdrCfgLabels
1.3.6.1.4.1.20044.95.9.2.1TablepmotdrCfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.95.9.2.1.1RowpmotdrCfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.95.9.2.1.1.1ColumnpmotdrCfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.95.9.2.1.1.3ColumnpmotdrCfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.95.9.2.2TablepmotdrCfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.95.9.2.2.1RowpmotdrCfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.95.9.2.2.1.1ColumnpmotdrCfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.95.9.2.2.1.3ColumnpmotdrCfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.95.9.257ScalarpmotdrCfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.95.10Nodepmotdrtraps
1.3.6.1.4.1.20044.95.10.2ScalarpmotdrtrapPortNumberread-onlycurrentLast port which generates a trap
1.3.6.1.4.1.20044.95.10.3ScalarpmotdrtrapLineNumberread-onlycurrentLast Line which generates a trap
1.3.6.1.4.1.20044.95.10.4ScalarpmotdrtrapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.95.10.34NotificationpmotdrLineTrapCritGoesOncurrentCritical Line default is activated
1.3.6.1.4.1.20044.95.10.35NotificationpmotdrLineTrapCritGoesOffcurrentCritical Line default disappeared
1.3.6.1.4.1.20044.95.10.50NotificationpmotdrPowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.95.10.51NotificationpmotdrPowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared
Type Definitions
NameSyntaxStatusDescription
PmotdrModeINTEGER { manual(0), auto(1) }currentDifferent modes on the OTDR SFP