MIB Viewer

EKINOPS-Rm10001wb-MIB

997 objects
Creation.
OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.86IdentitymoduleRm10001wbCreation.
1.3.6.1.4.1.20044.86.2Noderm10001wbalarms
1.3.6.1.4.1.20044.86.2.1Noderm10001wbAlmOther
1.3.6.1.4.1.20044.86.2.1.1Noderm10001wbAlmOtherNurg
1.3.6.1.4.1.20044.86.2.1.1.2Noderm10001wbAlmsynthAlm2
1.3.6.1.4.1.20044.86.2.1.1.2.1Scalarrm10001wbAlmConfTableSaveread-onlycurrentPM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> infor…
1.3.6.1.4.1.20044.86.2.1.1.2.2Scalarrm10001wbAlmInvUploadread-onlycurrentInventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> informationalStatus(1000) <Alarmtype> ot…
1.3.6.1.4.1.20044.86.2.1.1.2.3Scalarrm10001wbAlmConfTableLoadread-onlycurrentPM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> informationalStat…
1.3.6.1.4.1.20044.86.2.1.1.2.4Scalarrm10001wbAlmCorrelatOffread-onlycurrentNot Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> informationalStatus(1000) <Alarmtype…
1.3.6.1.4.1.20044.86.2.1.1.2.5Scalarrm10001wbAlmMaintenanceOnread-onlycurrentMaintenance Mode :This OID indicates that the RM is in maintenance mode. <Help> This alarm indicates that the maintenance mode is enabled on the PM <Condtype> …
1.3.6.1.4.1.20044.86.2.1.1.338Noderm10001wbAlmclientQsfpWarnDdm
1.3.6.1.4.1.20044.86.2.1.1.338.1Scalarrm10001wbAlmTrscv1VccLowWng1read-onlycurrentQ1 Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.86.2.1.1.338.2Scalarrm10001wbAlmTrscv1VccHighWng1read-onlycurrentQ1 Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.86.2.1.1.338.3Scalarrm10001wbAlmTrscv1TempLowWng1read-onlycurrentQ1 Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indicatin…
1.3.6.1.4.1.20044.86.2.1.1.338.4Scalarrm10001wbAlmTrscv1TempHighWng1read-onlycurrentQ1 Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning indicat…
1.3.6.1.4.1.20044.86.2.1.1.338.5Scalarrm10001wbAlmTrscv2VccLowWng1read-onlycurrentQ2 Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.86.2.1.1.338.6Scalarrm10001wbAlmTrscv2VccHighWng1read-onlycurrentQ2 Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.86.2.1.1.338.7Scalarrm10001wbAlmTrscv2TempLowWng1read-onlycurrentQ2 Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indicatin…
1.3.6.1.4.1.20044.86.2.1.1.338.8Scalarrm10001wbAlmTrscv2TempHighWng1read-onlycurrentQ2 Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning indicat…
1.3.6.1.4.1.20044.86.2.1.2Noderm10001wbAlmOtherUrg
1.3.6.1.4.1.20044.86.2.1.2.337Noderm10001wbAlmclientQsfpAlarmDdm
1.3.6.1.4.1.20044.86.2.1.2.337.1Scalarrm10001wbAlmTrscv1VccLowAla1read-onlycurrentQ1 Trscv Power Supply Low Alarm :This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM <Help> Al…
1.3.6.1.4.1.20044.86.2.1.2.337.2Scalarrm10001wbAlmTrscv1VccHighAla1read-onlycurrentQ1 Trscv Power Supply High Alarm :This OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM <Help> …
1.3.6.1.4.1.20044.86.2.1.2.337.3Scalarrm10001wbAlmTrscv1TempLowAla1read-onlycurrentQ1 Trscv Temp Low Alarm :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indic…
1.3.6.1.4.1.20044.86.2.1.2.337.4Scalarrm10001wbAlmTrscv1TempHighAlaread-onlycurrentQ1 Trscv Temp High Alarm :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm ind…
1.3.6.1.4.1.20044.86.2.1.2.337.5Scalarrm10001wbAlmTrscv2VccLowAla1read-onlycurrentQ2 Trscv Power Supply Low Alarm :This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM <Help> Al…
1.3.6.1.4.1.20044.86.2.1.2.337.6Scalarrm10001wbAlmTrscv2VccHighAla1read-onlycurrentQ2 Trscv Power Supply High Alarm :This OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM <Help> …
1.3.6.1.4.1.20044.86.2.1.2.337.7Scalarrm10001wbAlmTrscv2TempLowAla1read-onlycurrentQ2 Trscv Temp Low Alarm :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indic…
1.3.6.1.4.1.20044.86.2.1.2.337.8Scalarrm10001wbAlmTrscv2TempHighAla1read-onlycurrentQ2 Trscv Temp High Alarm :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm ind…
1.3.6.1.4.1.20044.86.2.1.3Noderm10001wbAlmOtherCrit
1.3.6.1.4.1.20044.86.2.1.3.0Noderm10001wbAlmsynthAlm0
1.3.6.1.4.1.20044.86.2.1.3.0.2Scalarrm10001wbAlmFailFanread-onlycurrentFan Fail :This OID is at 1 when any fail occurs on the fan tray <Help> This alarm indicates that the Fan tray module is in a failure condition <Condtype> FAIL_…
1.3.6.1.4.1.20044.86.2.1.3.0.9Scalarrm10001wbAlmModGlobFailread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the RM <Help> This alarm is set on detection of a failure originating from the equip…
1.3.6.1.4.1.20044.86.2.1.3.0.15Scalarrm10001wbAlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.86.2.1.3.0.16Scalarrm10001wbAlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.86.2.1.3.72Noderm10001wbAlmclientModuleState
1.3.6.1.4.1.20044.86.2.1.3.72.1Scalarrm10001wbAlmCfpInitializeread-onlycurrentClient Trscv Initialize :This OID indicates the Client Trscv initialization is in progress <Help> Status indicating the Client Trscv initialization is in progr…
1.3.6.1.4.1.20044.86.2.1.3.72.2Scalarrm10001wbAlmCfpLowPowerread-onlycurrentClient Trscv Low Power :This OID indicates the Client Trscv is in low power state <Help> Status indicating the Client Trscv is in low power state <Condtype> CF…
1.3.6.1.4.1.20044.86.2.1.3.72.3Scalarrm10001wbAlmCfpHighPowerUpread-onlycurrentClient Trscv High Power Up :This OID indicates the Client Trscv is leaving Low Power state <Help> Status indicating the Client Trscv is leaving Low Power state…
1.3.6.1.4.1.20044.86.2.1.3.72.4Scalarrm10001wbAlmCfpTxOffread-onlycurrentClient Trscv Laser Shutdown :This OID indicates the Client Trscv Laser is OFF <Help> Status indicating the Client Trscv Laser is OFF <Condtype> CFP_TX_OFF <Pro…
1.3.6.1.4.1.20044.86.2.1.3.72.5Scalarrm10001wbAlmCfpTxTurnOnread-onlycurrentClient Trscv Laser Turn On :This OID indicates the Client Trscv is turning on its laser <Help> Status indicating the Client Trscv is turning on its laser <Cond…
1.3.6.1.4.1.20044.86.2.1.3.72.6Scalarrm10001wbAlmCfpReadyread-onlycurrentClient Trscv Ready :This OID indicates the Client Trscv is ready to operate <Help> Status indicating the Client Trscv is ready to operate <Condtype> CFP_READY …
1.3.6.1.4.1.20044.86.2.1.3.72.7Scalarrm10001wbAlmCfpFaultread-onlycurrentClient Trscv Fault :This OID indicates the Client Trscv is in Fault state <Help> Status indicating the Client Trscv is in Fault state <Condtype> CFP_FAULT <Pro…
1.3.6.1.4.1.20044.86.2.1.3.72.8Scalarrm10001wbAlmCfpTxTurnOffread-onlycurrentClient Trscv Laser Turn Off :This OID indicates the Client Trscv is turning off its laser <Help> Status indicating the Client Trscv is turning off its laser <C…
1.3.6.1.4.1.20044.86.2.1.3.72.9Scalarrm10001wbAlmCfpHighPowerDownread-onlycurrentClient Trscv High Power Down :This OID indicates the Client Trscv is entering Low Power state <Help> Status indicating the Client Trscv is entering Low Power s…
1.3.6.1.4.1.20044.86.2.1.3.73Noderm10001wbAlmclientModuleGeneralStatus
1.3.6.1.4.1.20044.86.2.1.3.73.4Scalarrm10001wbAlmCfpOutOfAlignmentread-onlycurrentClient Trscv Out Of Alignment :This OID indicates an Out of alignment on the Client Trscv Host Interface <Help> Alarm indicating an Out of alignment on the Cli…
1.3.6.1.4.1.20044.86.2.1.3.73.5Scalarrm10001wbAlmCfpRxNetworkLolread-onlycurrentClient Trscv Rx Network Loss Of Lock :This OID indicates of Loss of Lock is dected on the Client Trscv Rx Network interface <Help> Alarm indicating of Loss of …
1.3.6.1.4.1.20044.86.2.1.3.73.6Scalarrm10001wbAlmCfpRxLosread-onlycurrentClient Trscv Loss Of Signal :This OID indicates a Loss of Signal is detected on the Client Trscv <Help> Alarm indicating a Loss of Signal is detected on the Cl…
1.3.6.1.4.1.20044.86.2.1.3.73.7Scalarrm10001wbAlmCfpTxHostLolread-onlycurrentClient Trscv Tx Host Loss Of Lock :This OID indicates of Loss of Lock is detected on the Client Trscv Tx Host interface <Help> Alarm indicating of Loss of Lock…
1.3.6.1.4.1.20044.86.2.1.3.73.8Scalarrm10001wbAlmCfpTxLosfread-onlycurrentClient Trscv Loss Of Signal Functionality :This OID indicates a Loss of Signal functionality is detected on the Client Trscv <Help> Alarm indicating a Loss of …
1.3.6.1.4.1.20044.86.2.1.3.73.9Scalarrm10001wbAlmCfpTxCmuLolread-onlycurrentClient Trscv CMU Loss Of Lock :This OID indicates a Clock Multiplier Unit Loss of Lock is detected on the Client Trscv <Help> Alarm indicating a Clock Multipli…
1.3.6.1.4.1.20044.86.2.1.3.73.10Scalarrm10001wbAlmCfpTxJitterPllLolread-onlycurrentClient Trscv Tx Jitter PLL Loss Of Lock :This OID indicates a Tx Jitter PLL Loss of Lock is dtected on the Client Trscv <Help> Alarm indicating a Tx Jitter PLL…
1.3.6.1.4.1.20044.86.2.1.3.73.11Scalarrm10001wbAlmCfpLossOfRefclkread-onlycurrentClient Trscv Loss Of Ref Clock :This OID indicates a Loss of Reference clock is detected on the Client Trscv <Help> Alarm indicating a Loss of Reference clock …
1.3.6.1.4.1.20044.86.2.1.3.73.14Scalarrm10001wbAlmCfpHwInterlockread-onlycurrentClient Trscv Hardware Interlock :This OID indicates the Client Trscv power is higher than the cooling capacity <Help> Alarm indicating the Client Trscv power i…
1.3.6.1.4.1.20044.86.2.1.3.74Noderm10001wbAlmclientGlobalAlarmSummary
1.3.6.1.4.1.20044.86.2.1.3.74.1Scalarrm10001wbAlmCfpSoftGlobAlarmTestread-onlycurrentClient Trscv Global Alarm SW Test :This OID indicates the Client Trscv Global Alarm This OID is raised by SW request for test purpose <Help> Status indicating …
1.3.6.1.4.1.20044.86.2.1.3.74.7Scalarrm10001wbAlmCfpNetworkLaneAlarmWarning2read-onlycurrentClient Trscv Network Alarm And Warning 2 :This OID indicates at least one DDM is detected on the Client Trscv Network Interface <Help> Synthesis alarm indicati…
1.3.6.1.4.1.20044.86.2.1.3.74.8Scalarrm10001wbAlmCfpModuleStateread-onlycurrentClient Trscv Module State :This OID indicates the Client Trscv module state <Help> Synthesis alarm indicating the Client Trscv module state <Condtype> CFP_MODU…
1.3.6.1.4.1.20044.86.2.1.3.74.9Scalarrm10001wbAlmCfpModuleGeneralStatusread-onlycurrentClient Trscv General Status :This OID indicates the Client Trscv module general status <Help> Synthesis alarm indicating the Client Trscv module general status…
1.3.6.1.4.1.20044.86.2.1.3.74.10Scalarrm10001wbAlmCfpModuleFaultread-onlycurrentClient Trscv Module Fault :This OID indicates at least one Fault is detected on the Client Trscv module <Help> Synthesis alarm indicating at least one Fault is…
1.3.6.1.4.1.20044.86.2.1.3.74.11Scalarrm10001wbAlmCfpModuleAlarmWarning1read-onlycurrentClient Trscv Module Alarm And Warning 1 :This OID indicates at least one DDM This OID is detected on the Client Trscv module <Help> Synthesis alarm indicating …
1.3.6.1.4.1.20044.86.2.1.3.74.12Scalarrm10001wbAlmCfpModuleAlarmWarning2read-onlycurrentClient Trscv Module Alarm And Warning 2 :This OID indicates at least one DDM is detected on the Client Trscv module <Help> Synthesis alarm indicating at least …
1.3.6.1.4.1.20044.86.2.1.3.74.13Scalarrm10001wbAlmCfpNetworkLaneAlarmWarning1read-onlycurrentClient Trscv Network Alarm And Warning 1 :This OID indicates at least one DDM is detected on the Client Trscv Network Interface <Help> Synthesis alarm indicati…
1.3.6.1.4.1.20044.86.2.1.3.74.14Scalarrm10001wbAlmCfpNetworkLaneFaultStatusread-onlycurrentClient Trscv Network Fault And Status :This OID indicates at least one Fault or Status is detected on the Client Trscv Network Interface <Help> Synthesis alarm…
1.3.6.1.4.1.20044.86.2.1.3.74.15Scalarrm10001wbAlmCfpHostLaneFaultStatusread-onlycurrentClient Trscv Host Fault And Status :This OID indicates at least one Fault or Status is detected on the Client Trscv Host Interface <Help> Synthesis alarm indic…
1.3.6.1.4.1.20044.86.2.1.3.74.16Scalarrm10001wbAlmCfpGlobAlarmAssertionread-onlycurrentClient Trscv Global Alarm :This OID indicates at least one Fault or Status is detected on the Client Trscv module <Help> Synthesis alarm indicating at least on…
1.3.6.1.4.1.20044.86.2.1.3.78Noderm10001wbAlmmsaModuleState
1.3.6.1.4.1.20044.86.2.1.3.78.1Scalarrm10001wbAlmMsaInitializeread-onlycurrentLine Trscv Initialize :This OID indicates the Line Trscv initialization is in progress <Help> Status indicating the Line Trscv initialization is in progress <C…
1.3.6.1.4.1.20044.86.2.1.3.78.2Scalarrm10001wbAlmMsaLowPowerread-onlycurrentLine Trscv Low Power :This OID indicates the Line Trscv is in low power state <Help> Status indicating the Line Trscv is in low power state <Condtype> MSA_LOW_…
1.3.6.1.4.1.20044.86.2.1.3.78.3Scalarrm10001wbAlmMsaHighPowerUpread-onlycurrentLine Trscv High Power Up :This OID indicates the Line Trscv is leaving Low Power state <Help> Status indicating the Line Trscv is leaving Low Power state <Cond…
1.3.6.1.4.1.20044.86.2.1.3.78.4Scalarrm10001wbAlmMsaTxOffread-onlycurrentLine Trscv Laser Shutdown :This OID indicates the Line Trscv Laser is OFF <Help> Status indicating the Line Trscv Laser is OFF <Condtype> MSA_TX_OFF <Probcause…
1.3.6.1.4.1.20044.86.2.1.3.78.5Scalarrm10001wbAlmMsaTxTurnOnread-onlycurrentLine Trscv Laser Turn On :This OID indicates the Line Trscv is turning on its laser <Help> Status indicating the Line Trscv is turning on its laser <Condtype> …
1.3.6.1.4.1.20044.86.2.1.3.78.6Scalarrm10001wbAlmMsaReadyread-onlycurrentLine Trscv Ready :This OID indicates the Line Trscv is ready to operate <Help> Status indicating the Line Trscv is ready to operate <Condtype> MSA_READY <Probc…
1.3.6.1.4.1.20044.86.2.1.3.78.7Scalarrm10001wbAlmMsaFaultread-onlycurrentLine Trscv Fault :This OID indicates the Line Trscv is in Fault state <Help> Status indicating the Line Trscv is in Fault state <Condtype> MSA_FAULT <Probcause…
1.3.6.1.4.1.20044.86.2.1.3.78.8Scalarrm10001wbAlmMsaTxTurnOffread-onlycurrentLine Trscv Laser Turn Off :This OID indicates the Line Trscv is turning off its laser <Help> Status indicating the Line Trscv is turning off its laser <Condtyp…
1.3.6.1.4.1.20044.86.2.1.3.78.9Scalarrm10001wbAlmMsaHighPowerDownread-onlycurrentLine Trscv High Power Down :This OID indicates the Line Trscv is entering Low Power state <Help> Status indicating the Line Trscv is entering Low Power state <…
1.3.6.1.4.1.20044.86.2.1.3.78.13Scalarrm10001wbAlmMsaTempShutdownread-onlycurrentLine Trscv Temperature Shutdown :This OID indicates a Trscv shutdown caused by a temperature is out of range<Help> Alarm indicating a Trscv temperature shutdow…
1.3.6.1.4.1.20044.86.2.1.3.78.14Scalarrm10001wbAlmMsaTempWarningread-onlycurrentLine Trscv Temperature Warning :This OID indicates a Trscv warning caused by a temperature is out of range<Help> Warning indicating a Trscv temperature out of …
1.3.6.1.4.1.20044.86.2.1.3.78.15Scalarrm10001wbAlmMsaTempAlarmread-onlycurrentLine Trscv Temperature Alarm :This OID indicates a Trscv alarm caused by a temperature is out of range<Help> Alarm indicating a Trscv temperature out of range …
1.3.6.1.4.1.20044.86.2.1.3.79Noderm10001wbAlmmsaModuleGeneralStatus
1.3.6.1.4.1.20044.86.2.1.3.79.4Scalarrm10001wbAlmMsaOutOfAlignmentread-onlycurrentLine Trscv Out Of Alignment :This OID indicates an Out of alignment on the Line Trscv Host Interface <Help> Alarm indicating an Out of alignment on the Line Tr…
1.3.6.1.4.1.20044.86.2.1.3.79.5Scalarrm10001wbAlmMsaRxNetworkLolread-onlycurrentLine Trscv Rx Network Loss Of Lock :This OID indicates of Loss of Lock is detected on the Line Trscv Rx Network interface <Help> Alarm indicating of Loss of Lo…
1.3.6.1.4.1.20044.86.2.1.3.79.6Scalarrm10001wbAlmMsaRxLosread-onlycurrentLine Trscv Loss Of Signal :This OID indicates a Loss of Signal is detected on the Line Trscv <Help> Alarm indicating a Loss of Signal is detected on the Line T…
1.3.6.1.4.1.20044.86.2.1.3.79.7Scalarrm10001wbAlmMsaTxHostLolread-onlycurrentLine Trscv Tx Host Loss Of Lock :This OID indicates of Loss of Lock is detected on the Line Trscv Tx Host interface <Help> Alarm indicating of Loss of Lock is …
1.3.6.1.4.1.20044.86.2.1.3.79.8Scalarrm10001wbAlmMsaTxLosfread-onlycurrentLine Trscv Loss Of Signal Functionality :This OID indicates a Loss of Signal functionality is detected on the Line Trscv <Help> Alarm indicating a Loss of Sign…
1.3.6.1.4.1.20044.86.2.1.3.79.9Scalarrm10001wbAlmMsaTxCmuLolread-onlycurrentLine Trscv CMU Loss Of Lock :This OID indicates a Clock Multiplier Unit Loss of Lock is detected on the Line Trscv <Help> Alarm indicating a Clock Multiplier U…
1.3.6.1.4.1.20044.86.2.1.3.79.10Scalarrm10001wbAlmMsaTxJitterPllLolread-onlycurrentLine Trscv Tx Jitter PLL Loss Of Lock :This OID indicates a Tx Jitter PLL Loss of Lock is detected on the Line Trscv <Help> Alarm indicating a Tx Jitter PLL Lo…
1.3.6.1.4.1.20044.86.2.1.3.79.11Scalarrm10001wbAlmMsaLossOfRefclkread-onlycurrentLine Trscv Loss Of Ref Clock :This OID indicates a Loss of Reference clock is detected on the Line Trscv <Help> Alarm indicating a Loss of Reference clock is d…
1.3.6.1.4.1.20044.86.2.1.3.79.14Scalarrm10001wbAlmMsaHwInterlockread-onlycurrentLine Trscv Hardware Interlock :This OID indicates the Line Trscv power is higher than the cooling capacity <Help> Alarm indicating the Line Trscv power is high…
1.3.6.1.4.1.20044.86.2.1.3.80Noderm10001wbAlmmsaGlobalAlarmSummary
1.3.6.1.4.1.20044.86.2.1.3.80.1Scalarrm10001wbAlmMsaSoftGlobAlarmTestread-onlycurrentLine Trscv Global Alarm SW Test :This OID indicates the Line Trscv Global alarm This OID is raised by SW request for test purpose <Help> Status indicating the …
1.3.6.1.4.1.20044.86.2.1.3.80.6Scalarrm10001wbAlmMsaNetworkHostAlarmStatusread-onlycurrentLine Trscv Network/Host Alarm Status :This OID indicates the state of the Network and Host interface of the Line Trscv <Help> Synthesis alarm indicating the al…
1.3.6.1.4.1.20044.86.2.1.3.80.7Scalarrm10001wbAlmMsaNetworkLaneAlarmWarning2read-onlycurrentLine Trscv Network Alarm And Warning 2 :This OID indicates at least one DDM This OID is detected on the Line Trscv Network Interface <Help> Synthesis alarm ind…
1.3.6.1.4.1.20044.86.2.1.3.80.8Scalarrm10001wbAlmMsaModuleStateread-onlycurrentLine Trscv Module State :This OID indicates the Line Trscv module state <Help> Synthesis alarm indicating the Line Trscv module state <Condtype> MSA_MODULE_STA…
1.3.6.1.4.1.20044.86.2.1.3.80.9Scalarrm10001wbAlmMsaModuleGeneralStatusread-onlycurrentLine Trscv General Status :This OID indicates the Line Trscv module general <Help> Synthesis alarm indicating the Line Trscv module general status <Condtype> M…
1.3.6.1.4.1.20044.86.2.1.3.80.10Scalarrm10001wbAlmModuleFaultread-onlycurrentLine Trscv Module Fault :This OID indicates at least one Fault is detected on the Line Trscv module <Help> Synthesis alarm indicating at least one Fault is det…
1.3.6.1.4.1.20044.86.2.1.3.80.11Scalarrm10001wbAlmMsaModuleAlarmWarning1read-onlycurrentLine Trscv Module Alarm And Warning 1 :This OID indicates at least one DDM is detected on the Line Trscv module <Help> Synthesis alarm indicating at least one …
1.3.6.1.4.1.20044.86.2.1.3.80.12Scalarrm10001wbAlmMsaModuleAlarmWarning2read-onlycurrentLine Trscv Module Alarm And Warning 2 :This OID indicates at least one DDM is detected on the Line Trscv module <Help> Synthesis alarm indicating at least one …
1.3.6.1.4.1.20044.86.2.1.3.80.13Scalarrm10001wbAlmMsaNetworkLaneAlarmWarning1read-onlycurrentLine Trscv Network Alarm And Warning 1 :This OID indicates at least one DDM is detected on the Line Trscv Network Interface <Help> Synthesis alarm indicating a…
1.3.6.1.4.1.20044.86.2.1.3.80.14Scalarrm10001wbAlmMsaNetworkLaneFaultStatusread-onlycurrentLine Trscv Network Fault And Status :This OID indicates at least one Fault or Status is detected on the Line Trscv Network Interface <Help> Synthesis alarm ind…
1.3.6.1.4.1.20044.86.2.1.3.80.15Scalarrm10001wbAlmMsaHostLaneFaultStatusread-onlycurrentLine Trscv Host Fault And Status :This OID indicates at least one Fault or Status is detected on the Line Trscv Host Interface <Help> Synthesis alarm indicatin…
1.3.6.1.4.1.20044.86.2.1.3.80.16Scalarrm10001wbAlmMsaGlobAlarmAssertionread-onlycurrentLine Trscv Global Alarm :This OID indicates at least one Fault or Status is detected on the Line Trscv module <Help> Synthesis alarm indicating at least one Al…
1.3.6.1.4.1.20044.86.2.1.3.81Noderm10001wbAlmmsaNetworkTxAlignment
1.3.6.1.4.1.20044.86.2.1.3.81.12Scalarrm10001wbAlmNetTxTimingFaultread-onlycurrentLine Trscv Network Tx Timing Fault :This OID indicates a Tx Timing Fault is detected on the Line Trscv Network interface <Help> Alarm indicating a Tx Timing Fa…
1.3.6.1.4.1.20044.86.2.1.3.81.13Scalarrm10001wbAlmNetTxReferenceClockFaultread-onlycurrentLine Trscv Network Tx Ref Clock Fault :This OID indicates a Tx Reference Clock Fault is detected on the Line Trscv Network interface <Help> Alarm indicating a …
1.3.6.1.4.1.20044.86.2.1.3.81.14Scalarrm10001wbAlmNetTxCmuLockFaultread-onlycurrentLine Trscv Network Tx CMU Lock Fault :This OID indicates a Tx Clock Multiplier Unit Lock Fault is detected on the Line Trscv Network interface <Help> Alarm ind…
1.3.6.1.4.1.20044.86.2.1.3.81.15Scalarrm10001wbAlmNetTxOutOfAlignmentread-onlycurrentLine Trscv Network Tx Out Of Alignment :This OID indicates a Tx Out of Alignment is detected on the Line Trscv Network interface <Help> Alarm indicating a Tx O…
1.3.6.1.4.1.20044.86.2.1.3.81.16Scalarrm10001wbAlmNetTxLossOfAlignmentread-onlycurrentLine Trscv Network Tx Loss Of Alignment :This OID indicates a Tx Loss of Alignment is detected on the Line Trscv Network interface <Help> Alarm indicating a Tx…
1.3.6.1.4.1.20044.86.2.1.3.82Noderm10001wbAlmmsaNetworkRxAlignment
1.3.6.1.4.1.20044.86.2.1.3.82.12Scalarrm10001wbAlmNetRxTimingFaultread-onlycurrentLine Trscv Network Rx Timing Fault :This OID indicates a Rx Timing Fault is detected on the Line Trscv Network interface <Help> Alarm indicating a Rx Timing Fa…
1.3.6.1.4.1.20044.86.2.1.3.82.13Scalarrm10001wbAlmNetRxOutOfAlignmentread-onlycurrentLine Trscv Network Rx Out Of Alignment :This OID indicates a Rx Out of Alignment is detected on the Line Trscv Network interface <Help> Alarm indicating a Rx O…
1.3.6.1.4.1.20044.86.2.1.3.82.14Scalarrm10001wbAlmNetRxLossOfAlignmentread-onlycurrentLine Trscv Network Rx Loss Of Alignment :This OID indicates a Rx Loss of Alignment is detected on the Line Trscv Network interface <Help> Alarm indicating a Rx…
1.3.6.1.4.1.20044.86.2.1.3.82.15Scalarrm10001wbAlmNetRxModemLockFaultread-onlycurrentLine Trscv Network Rx Modem Lock Fault :This OID indicates a Rx Modem Lock Fault is detected on the Line Trscv Network interface <Help> Alarm indicating a Rx M…
1.3.6.1.4.1.20044.86.2.1.3.82.16Scalarrm10001wbAlmNetRxModemSyncDetectFaultread-onlycurrentLine Trscv Network Rx Modem Sync Detect Fault :This OID indicates a Rx Modem Synchronisation Detection Fault is detected on the Line Trscv Network interface <H…
1.3.6.1.4.1.20044.86.2.1.3.83Noderm10001wbAlmmsaNetworkHostNetworkAlarmSummary
1.3.6.1.4.1.20044.86.2.1.3.83.11Scalarrm10001wbAlmNetworkTxAlignmentread-onlycurrentLine Trscv Network Tx Alignment :This OID indicates a Tx Alignment Fault is detected on the Line Trscv Network interface <Help> Synthesis Alarm indicating a Tx…
1.3.6.1.4.1.20044.86.2.1.3.83.12Scalarrm10001wbAlmNetworkRxAlignmentread-onlycurrentLine Trscv Network Rx Alignment :This OID indicates a Rx Alignment Fault is detected on the Line Trscv Network interface <Help> Synthesis Alarm indicating a Rx…
1.3.6.1.4.1.20044.86.2.1.3.83.13Scalarrm10001wbAlmNetworkRxOtnread-onlycurrentLine Trscv Network Rx OTN :This OID indicates a Rx OTN Fault is detected on the Line Trscv Network interface <Help> Synthesis Alarm indicating a Rx OTN Fault i…
1.3.6.1.4.1.20044.86.2.1.3.83.14Scalarrm10001wbAlmHostRxAlignmentread-onlycurrentLine Trscv Host Rx Alignment :This OID indicates a Rx Alignment Fault is detected on the Line Trscv Host interface <Help> Synthesis Alarm indicating a Rx Align…
1.3.6.1.4.1.20044.86.2.1.3.83.15Scalarrm10001wbAlmHostTxAlignmentread-onlycurrentLine Trscv Host Tx Alignment :This OID indicates a Tx Alignment Fault is detected on the Line Trscv Host interface <Help> Synthesis Alarm indicating a Tx Align…
1.3.6.1.4.1.20044.86.2.1.3.83.16Scalarrm10001wbAlmHostTxOtnStatusread-onlycurrentLine Trscv Host Tx OTN :This OID indicates a Tx OTN Fault is detected on the Line Trscv Host interface <Help> Synthesis Alarm indicating a Tx OTN Fault is dete…
1.3.6.1.4.1.20044.86.2.1.3.84Noderm10001wbAlmmsaHostTxAlignment
1.3.6.1.4.1.20044.86.2.1.3.84.13Scalarrm10001wbAlmHostTxDeskewLockFaultread-onlycurrentLine Trscv Host Tx Deskew Lock Fault :This OID indicates a Tx Deskew Lock Fault is detected on the Line Trscv Host interface <Help> Alarm indicating a Tx Deske…
1.3.6.1.4.1.20044.86.2.1.3.84.14Scalarrm10001wbAlmHostTxOutOfAlignmentread-onlycurrentLine Trscv Host Tx Out Of Alignment :This OID indicates a Tx Out of Alignment is detected on the Line Trscv Host interface <Help> Alarm indicating a Tx Out of …
1.3.6.1.4.1.20044.86.2.1.3.84.15Scalarrm10001wbAlmHostTxLossOfAlignmentread-onlycurrentLine Trscv Host Tx Loss Of Alignment :This OID indicates a Tx Loss of Alignment is detected on the Line Trscv Host interface <Help> Alarm indicating a Tx Loss …
1.3.6.1.4.1.20044.86.2.1.3.84.16Scalarrm10001wbAlmHostTxCdrLockFaultread-onlycurrentLine Trscv Host Tx CDR Lock Fault :This OID indicates a Tx Clock Data Recovery Lock Fault is detected on the Line Trscv Host interface <Help> Alarm indicating …
1.3.6.1.4.1.20044.86.2.1.3.85Noderm10001wbAlmmsaHostRxAlignment
1.3.6.1.4.1.20044.86.2.1.3.85.14Scalarrm10001wbAlmHostRxCmuLockFaultread-onlycurrentLine Trscv Host Rx CMU Lock Fault :This OID indicates a Rx Clock Multiplier Unit Lock Fault is detected on the Line Trscv Host interface <Help> Alarm indicatin…
1.3.6.1.4.1.20044.86.2.1.3.85.15Scalarrm10001wbAlmHostRxOutOfAlignmentread-onlycurrentLine Trscv Host Rx Out Of Alignment :This OID indicates a Rx Out of Alignment is detected on the Line Trscv Host interface <Help> Alarm indicating a Rx Out of …
1.3.6.1.4.1.20044.86.2.1.3.85.16Scalarrm10001wbAlmHostRxLossOfAlignmentread-onlycurrentLine Trscv Host Rx Loss Of Alignment :This OID indicates a Rx Loss of Alignment is detected on the Line Trscv Host interface <Help> Alarm indicating a Rx Loss …
1.3.6.1.4.1.20044.86.2.2Noderm10001wbAlmClient
1.3.6.1.4.1.20044.86.2.2.1Noderm10001wbAlmClientNurg
1.3.6.1.4.1.20044.86.2.2.1.272Tablerm10001wbAlmclientSfpWarnDdmTablenot-accessiblecurrentList of rm10001wbAlmclientSfpWarnDdm Article
1.3.6.1.4.1.20044.86.2.2.1.272.1Rowrm10001wbAlmclientSfpWarnDdmEntrynot-accessiblecurrentRow definition for the rm10001wbAlmclientSfpWarnDdm table
1.3.6.1.4.1.20044.86.2.2.1.272.1.1Columnrm10001wbAlmclientSfpWarnDdmIndexread-onlycurrentIndex definition for the rm10001wbAlmclientSfpWarnDdm table
1.3.6.1.4.1.20044.86.2.2.1.272.1.2Columnrm10001wbAlmTxPwLowWngPortnread-onlycurrentClient Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.86.2.2.1.272.1.3Columnrm10001wbAlmTxPwrHighWngPortnread-onlycurrentClient Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.86.2.2.1.272.1.4Columnrm10001wbAlmTxBiasLowWngPortnread-onlycurrentClient Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.86.2.2.1.272.1.5Columnrm10001wbAlmTxBiasHighWngPortnread-onlycurrentClient Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warn…
1.3.6.1.4.1.20044.86.2.2.1.272.1.16Columnrm10001wbAlmRxPwrLowWngPortnread-onlycurrentClient Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning i…
1.3.6.1.4.1.20044.86.2.2.1.272.1.17Columnrm10001wbAlmRxPwrHighWngPortnread-onlycurrentClient Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning…
1.3.6.1.4.1.20044.86.2.2.2Noderm10001wbAlmClientUrg
1.3.6.1.4.1.20044.86.2.2.2.152Tablerm10001wbAlmclientHostLaneFaultTablenot-accessiblecurrentList of rm10001wbAlmclientHostLaneFault Article
1.3.6.1.4.1.20044.86.2.2.2.152.1Rowrm10001wbAlmclientHostLaneFaultEntrynot-accessiblecurrentRow definition for the rm10001wbAlmclientHostLaneFault table
1.3.6.1.4.1.20044.86.2.2.2.152.1.1Columnrm10001wbAlmclientHostLaneFaultIndexread-onlycurrentIndex definition for the rm10001wbAlmclientHostLaneFault table
1.3.6.1.4.1.20044.86.2.2.2.152.1.2Columnrm10001wbAlmClientLossOfSyncPortnread-onlycurrentClient Frame Alignment Loss :This OID indicates the module is not aligned with the incoming Client signal <Help> Alarm indicating the module is not aligned wit…
1.3.6.1.4.1.20044.86.2.2.2.152.1.3Columnrm10001wbAlmClientInputLossOfSigPortnread-onlycurrentClient Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Client Trscv <Help> Alarm indicating a Loss of Signal is detected on the Cl…
1.3.6.1.4.1.20044.86.2.2.2.152.1.4Columnrm10001wbAlmClientLanesMarkerUnlockPortnread-onlycurrentClient Lanes Marker Unlock :This OID indicates the Client lanes marker alignment is not lock <Help> Alarm indicating the Client lanes marker alignment is not l…
1.3.6.1.4.1.20044.86.2.2.2.152.1.5Columnrm10001wbAlmClientLanes6466UnlockPortnread-onlycurrentClient Lanes 64/66b Unlock :This OID indicates the Client 64/66b decoder is not lock <Help> Alarm indicating the Client 64/66b decoder is not lock <Condtype> C…
1.3.6.1.4.1.20044.86.2.2.2.152.1.6Columnrm10001wbAlmClientLanesNotAlignedPortnread-onlycurrentClient Lanes Not Aligned :This OID indicates the Client lanes are not aligned <Help> Alarm indicating the Client lanes are not aligned <Condtype> CLIENT_LANES_…
1.3.6.1.4.1.20044.86.2.2.2.152.1.7Columnrm10001wbAlmClientCsfDetectedPortnread-onlycurrentClient Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client…
1.3.6.1.4.1.20044.86.2.2.2.152.1.10Columnrm10001wbAlmClientTxHostLolPortnread-onlycurrentClient Host Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Client Trscv Host Lane <Help> Alarm indicating a Tx Loss of Lock on the Client Tr…
1.3.6.1.4.1.20044.86.2.2.2.152.1.11Columnrm10001wbAlmClientLaneTxFifoErrorPortnread-onlycurrentClient Host Lane Tx FIFO Error :This OID indicates a Tx FIFO Error on the Client Trscv Host Lane <Help> Alarm indicating a Tx FIFO Error on the Client Trscv Ho…
1.3.6.1.4.1.20044.86.2.2.2.240Tablerm10001wbAlmclientSfpAlmDdmTablenot-accessiblecurrentList of rm10001wbAlmclientSfpAlmDdm Article
1.3.6.1.4.1.20044.86.2.2.2.240.1Rowrm10001wbAlmclientSfpAlmDdmEntrynot-accessiblecurrentRow definition for the rm10001wbAlmclientSfpAlmDdm table
1.3.6.1.4.1.20044.86.2.2.2.240.1.1Columnrm10001wbAlmclientSfpAlmDdmIndexread-onlycurrentIndex definition for the rm10001wbAlmclientSfpAlmDdm table
1.3.6.1.4.1.20044.86.2.2.2.240.1.2Columnrm10001wbAlmTxPwrLowAlaPortnread-onlycurrentClient Trscv Tx Power Low :This OID indicates that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in…
1.3.6.1.4.1.20044.86.2.2.2.240.1.3Columnrm10001wbAlmTxPwrHighAlaPortnread-onlycurrentClient Trscv Tx Power High :This OID indicates that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.86.2.2.2.240.1.4Columnrm10001wbAlmTxBiasLowAlaPortnread-onlycurrentClient Trscv Bias Low :This OID indicates that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.86.2.2.2.240.1.5Columnrm10001wbAlmTxBiasHighAlaPortnread-onlycurrentClient Trscv Bias High :This OID indicates that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM <Help> Alar…
1.3.6.1.4.1.20044.86.2.2.2.240.1.16Columnrm10001wbAlmRxPwrLowAlaPortnread-onlycurrentClient Trscv Rx Power Low :This OID indicates that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm ind…
1.3.6.1.4.1.20044.86.2.2.2.240.1.17Columnrm10001wbAlmRxPwrHighAlaPortnread-onlycurrentClient Trscv Rx Power High :This OID indicates that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm i…
1.3.6.1.4.1.20044.86.2.2.3Noderm10001wbAlmClientCrit
1.3.6.1.4.1.20044.86.2.2.3.8Tablerm10001wbAlmsynthAlmPortTablenot-accessiblecurrentList of rm10001wbAlmsynthAlmPort Article
1.3.6.1.4.1.20044.86.2.2.3.8.1Rowrm10001wbAlmsynthAlmPortEntrynot-accessiblecurrentRow definition for the rm10001wbAlmsynthAlmPort table
1.3.6.1.4.1.20044.86.2.2.3.8.1.1Columnrm10001wbAlmsynthAlmPortIndexread-onlycurrentIndex definition for the rm10001wbAlmsynthAlmPort table
1.3.6.1.4.1.20044.86.2.2.3.8.1.2Columnrm10001wbAlmSfpAbsentPortnread-onlycurrentClient Optical Module Absent :This OID indicates that the Transceiver is not present in the client port. <Help> This alarm indicates if the client transceiver …
1.3.6.1.4.1.20044.86.2.2.3.8.1.3Columnrm10001wbAlmDdmAbsentPortnread-onlycurrentDDM Supported On Client Trscv :This OID indicates that the Client transceiver supports the Digital Diagnostic Monitoring function <Help> This status indicates …
1.3.6.1.4.1.20044.86.2.2.3.8.1.5Columnrm10001wbAlmHwFailAccPortnread-onlycurrentClient HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Help> This alarm indicates a failure on client port, most pro…
1.3.6.1.4.1.20044.86.2.2.3.8.1.6Columnrm10001wbAlmDwLsdPortnread-onlycurrentClient Trscv Laser Shutdown :This OID indicates the Client transceiver laser is shutdown <Help> This status indicates if the client transceiver laser is shutdo…
1.3.6.1.4.1.20044.86.2.2.3.8.1.7Columnrm10001wbAlmClientLocalOosPortnread-onlycurrentLocal Client Port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local c…
1.3.6.1.4.1.20044.86.2.2.3.8.1.8Columnrm10001wbAlmClientRemoteOosPortnread-onlycurrentRemote Client Port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the remot…
1.3.6.1.4.1.20044.86.2.2.3.8.1.9Columnrm10001wbAlmDwCaisPortnread-onlycurrentClient AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indicates if a Client Alarm Indication Signal is…
1.3.6.1.4.1.20044.86.2.2.3.8.1.10Columnrm10001wbAlmSfpDdmWarningPortnread-onlycurrentWarning On Client Trscv DDM :This OID indicates a warning is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Warning has be…
1.3.6.1.4.1.20044.86.2.2.3.8.1.11Columnrm10001wbAlmSfpDdmAlmPortnread-onlycurrentAlarm On Client Trscv DDM :This OID indicates an alarm is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Alarm has been de…
1.3.6.1.4.1.20044.86.2.2.3.8.1.13Columnrm10001wbAlmFailAccPortnread-onlycurrentClient Access Fail :This OID indicates a failure on the Client port <Help> This alarm indicates a failure on the Client port <Condtype> FAIL_ACC_1 <Probcause> …
1.3.6.1.4.1.20044.86.2.2.3.8.1.17Columnrm10001wbAlmUpCsfPortnread-onlycurrentClient Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu…
1.3.6.1.4.1.20044.86.2.3Noderm10001wbAlmLine
1.3.6.1.4.1.20044.86.2.3.1Noderm10001wbAlmLineNurg
1.3.6.1.4.1.20044.86.2.3.1.184Tablerm10001wbAlmlineNetworkLaneAlarmWarning1Tablenot-accessiblecurrentList of rm10001wbAlmlineNetworkLaneAlarmWarning1 Article
1.3.6.1.4.1.20044.86.2.3.1.184.1Rowrm10001wbAlmlineNetworkLaneAlarmWarning1Entrynot-accessiblecurrentRow definition for the rm10001wbAlmlineNetworkLaneAlarmWarning1 table
1.3.6.1.4.1.20044.86.2.3.1.184.1.1Columnrm10001wbAlmlineNetworkLaneAlarmWarning1Indexread-onlycurrentIndex definition for the rm10001wbAlmlineNetworkLaneAlarmWarning1 table
1.3.6.1.4.1.20044.86.2.3.1.184.1.2Columnrm10001wbAlmLineRxPowerLowAlarmPortnread-onlycurrentLine Trscv Rx Power Low Alarm :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicat…
1.3.6.1.4.1.20044.86.2.3.1.184.1.3Columnrm10001wbAlmLineRxPowerLowWarningPortnread-onlycurrentLine Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning ind…
1.3.6.1.4.1.20044.86.2.3.1.184.1.4Columnrm10001wbAlmLineRxPowerHighWarningPortnread-onlycurrentLine Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning i…
1.3.6.1.4.1.20044.86.2.3.1.184.1.5Columnrm10001wbAlmLineRxPowerHighAlarmPortnread-onlycurrentLine Trscv Rx Power High Alarm :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indic…
1.3.6.1.4.1.20044.86.2.3.1.184.1.6Columnrm10001wbAlmLineLaserTempLowAlarmPortnread-onlycurrentLine Trscv Tx Laser Temp Low Alarm :This OID indicates that the Trscv Tx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help>…
1.3.6.1.4.1.20044.86.2.3.1.184.1.7Columnrm10001wbAlmLineLaserTempLowWarningPortnread-onlycurrentLine Trscv Tx Laser Temp Low Warning :This OID indicates that the Trscv Tx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Hel…
1.3.6.1.4.1.20044.86.2.3.1.184.1.8Columnrm10001wbAlmLineLaserTempHighWarningPortnread-onlycurrentLine Trscv Tx Laser Temp High Warning :This OID indicates that the Trscv Tx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <H…
1.3.6.1.4.1.20044.86.2.3.1.184.1.9Columnrm10001wbAlmLineLaserTempHighAlarmPortnread-onlycurrentLine Trscv Tx Laser Temp High Alarm :This OID indicates that the Trscv Tx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Hel…
1.3.6.1.4.1.20044.86.2.3.1.184.1.10Columnrm10001wbAlmLineTxPowerLowAlarmPortnread-onlycurrentLine Trscv Tx Power Low Alarm :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indica…
1.3.6.1.4.1.20044.86.2.3.1.184.1.11Columnrm10001wbAlmLineTxPowerLowWarningPortnread-onlycurrentLine Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning in…
1.3.6.1.4.1.20044.86.2.3.1.184.1.12Columnrm10001wbAlmLineTxPowerHighWarningPortnread-onlycurrentLine Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.86.2.3.1.184.1.13Columnrm10001wbAlmLineTxPowerHighAlarmPortnread-onlycurrentLine Trscv Tx Power High Alarm :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indi…
1.3.6.1.4.1.20044.86.2.3.1.184.1.14Columnrm10001wbAlmLineBiasLowAlarmPortnread-onlycurrentLine Trscv Tx Bias Low Alarm :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alarm i…
1.3.6.1.4.1.20044.86.2.3.1.184.1.15Columnrm10001wbAlmLineBiasLowWarningPortnread-onlycurrentLine Trscv Tx Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warni…
1.3.6.1.4.1.20044.86.2.3.1.184.1.16Columnrm10001wbAlmLineBiasHighWarningPortnread-onlycurrentLine Trscv Tx Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> War…
1.3.6.1.4.1.20044.86.2.3.1.184.1.17Columnrm10001wbAlmLineBiasHighAlarmPortnread-onlycurrentLine Trscv Tx Bias High Alarm :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Alarm…
1.3.6.1.4.1.20044.86.2.3.1.188Tablerm10001wbAlmlineNetworkLaneAlarmWarning2Tablenot-accessiblecurrentList of rm10001wbAlmlineNetworkLaneAlarmWarning2 Article
1.3.6.1.4.1.20044.86.2.3.1.188.1Rowrm10001wbAlmlineNetworkLaneAlarmWarning2Entrynot-accessiblecurrentRow definition for the rm10001wbAlmlineNetworkLaneAlarmWarning2 table
1.3.6.1.4.1.20044.86.2.3.1.188.1.1Columnrm10001wbAlmlineNetworkLaneAlarmWarning2Indexread-onlycurrentIndex definition for the rm10001wbAlmlineNetworkLaneAlarmWarning2 table
1.3.6.1.4.1.20044.86.2.3.1.188.1.2Columnrm10001wbAlmTxModulatorBiasLowAlarmPortnread-onlycurrentLine Trscv Tx Modulator Bias Low Alarm :This OID indicates that the Trscv Tx modulator bias current is lower than the threshold value written in the Trscv EEPR…
1.3.6.1.4.1.20044.86.2.3.1.188.1.3Columnrm10001wbAlmTxModulatorBiasLowWarningPortnread-onlycurrentLine Trscv Tx Modulator Bias Low Warning :This OID indicates that the Trscv Tx modulator bias current is lower than the threshold value written in the Trscv EE…
1.3.6.1.4.1.20044.86.2.3.1.188.1.4Columnrm10001wbAlmTxModulatorBiasHighWarningPortnread-onlycurrentLine Trscv Tx Modulator Bias High Warning :This OID indicates that the Trscv Tx modulator bias current is higher than the threshold value written in the Trscv …
1.3.6.1.4.1.20044.86.2.3.1.188.1.5Columnrm10001wbAlmTxModulatorBiasHighAlarmPortnread-onlycurrentLine Trscv Tx Modulator Bias High Alarm :This OID indicates that the Trscv Tx modulator bias current is higher than the threshold value written in the Trscv EE…
1.3.6.1.4.1.20044.86.2.3.1.188.1.6Columnrm10001wbAlmRxLaserTempLowAlarmPortnread-onlycurrentLine Trscv Rx Laser Temp Low Alarm :This OID indicates that the Trscv Rx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help>…
1.3.6.1.4.1.20044.86.2.3.1.188.1.7Columnrm10001wbAlmRxLaserTempLowWarningPortnread-onlycurrentLine Trscv Rx Laser Temp Low Warning :This OID indicates that the Trscv Rx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Hel…
1.3.6.1.4.1.20044.86.2.3.1.188.1.8Columnrm10001wbAlmRxLaserTempHighWarningPortnread-onlycurrentLine Trscv Rx Laser Temp High Warning :This OID indicates that the Trscv Rx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <H…
1.3.6.1.4.1.20044.86.2.3.1.188.1.9Columnrm10001wbAlmRxLaserTempHighAlarmPortnread-onlycurrentLine Trscv Rx Laser Temp High Alarm :This OID indicates that the Trscv Rx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Hel…
1.3.6.1.4.1.20044.86.2.3.1.188.1.10Columnrm10001wbAlmRxLaserOutputLowAlarmPortnread-onlycurrentLine Trscv Rx Output Power Low Alarm :This OID indicates that the Trscv Rx output power is lower than the threshold value written in the Trscv EEPROM <Help> Al…
1.3.6.1.4.1.20044.86.2.3.1.188.1.11Columnrm10001wbAlmRxLaserOutputLowWarningPortnread-onlycurrentLine Trscv Rx Output Power Low Warning :This OID indicates that the Trscv Rx output power is lower than the threshold value written in the Trscv EEPROM <Help> …
1.3.6.1.4.1.20044.86.2.3.1.188.1.12Columnrm10001wbAlmRxLaserOutputHighWarningPortnread-onlycurrentLine Trscv Rx Output Power High Warning :This OID indicates that the Trscv Rx output power is higher than the threshold value written in the Trscv EEPROM <Help…
1.3.6.1.4.1.20044.86.2.3.1.188.1.13Columnrm10001wbAlmRxLaserOutputHighAlarmPortnread-onlycurrentLine Trscv Rx Output Power High Alarm :This OID indicates that the Trscv Rx output power is higher than the threshold value written in the Trscv EEPROM <Help> …
1.3.6.1.4.1.20044.86.2.3.1.188.1.14Columnrm10001wbAlmRxLaserBiasLowAlarmPortnread-onlycurrentLine Trscv Rx Bias Low Alarm :This OID indicates that the Trscv Rx laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alar…
1.3.6.1.4.1.20044.86.2.3.1.188.1.15Columnrm10001wbAlmRxLaserBiasLowWarningPortnread-onlycurrentLine Trscv Rx Bias Low Warning :This OID indicates that the Trscv Rx laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Wa…
1.3.6.1.4.1.20044.86.2.3.1.188.1.16Columnrm10001wbAlmRxLaserBiasHighWarningPortnread-onlycurrentLine Trscv Rx Bias High Warning :This OID indicates that the Trscv Rx laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> …
1.3.6.1.4.1.20044.86.2.3.1.188.1.17Columnrm10001wbAlmRxLaserBiasHighAlarmPortnread-onlycurrentLine Trscv Rx Bias High Alarm :This OID indicates that the Trscv Rx laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Al…
1.3.6.1.4.1.20044.86.2.3.2Noderm10001wbAlmLineUrg
1.3.6.1.4.1.20044.86.2.3.2.192Tablerm10001wbAlmlineNetworkLaneFaultTablenot-accessiblecurrentList of rm10001wbAlmlineNetworkLaneFault Article
1.3.6.1.4.1.20044.86.2.3.2.192.1Rowrm10001wbAlmlineNetworkLaneFaultEntrynot-accessiblecurrentRow definition for the rm10001wbAlmlineNetworkLaneFault table
1.3.6.1.4.1.20044.86.2.3.2.192.1.1Columnrm10001wbAlmlineNetworkLaneFaultIndexread-onlycurrentIndex definition for the rm10001wbAlmlineNetworkLaneFault table
1.3.6.1.4.1.20044.86.2.3.2.192.1.3Columnrm10001wbAlmLineLaneRxTecFaultPortnread-onlycurrentLine Network Lane Rx TEC Fault :This OID indicates a Rx TEC Fault on the Line Trscv Network Lane <Help> Alarm indicating a Rx TEC Fault on the Line Trscv Netwo…
1.3.6.1.4.1.20044.86.2.3.2.192.1.4Columnrm10001wbAlmLineLaneRxFifoErrorPortnread-onlycurrentLine Network Lane Rx FIFO Error :This OID indicates a Rx FIFO Error on the Line Trscv Network Lane <Help> Alarm indicating a Rx FIFO Error on the Line Trscv Ne…
1.3.6.1.4.1.20044.86.2.3.2.192.1.5Columnrm10001wbAlmLineLaneRxLolPortnread-onlycurrentLine Network Lane Rx Loss Of Lock :This OID indicates a Rx Loss of Lock on the Line Trscv Network Lane <Help> Alarm indicating a Rx Loss of Lock on the Line Tr…
1.3.6.1.4.1.20044.86.2.3.2.192.1.6Columnrm10001wbAlmLineLaneRxLosPortnread-onlycurrentLine Network Lane Rx Loss Of Signal :This OID indicates a Rx Loss of Signal on the Line Trscv Network Lane <Help> Alarm indicating a Rx Loss of Signal on the L…
1.3.6.1.4.1.20044.86.2.3.2.192.1.8Columnrm10001wbAlmLineLaneTxLolPortnread-onlycurrentLine Network Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Line Trscv Network Lane <Help> Alarm indicating a Tx Loss of Lock on the Line Tr…
1.3.6.1.4.1.20044.86.2.3.2.192.1.9Columnrm10001wbAlmLineLaneTxLosfPortnread-onlycurrentLine Network Lane Tx Loss Of Signal Functionality :This OID indicates a Tx Loss of Signal Functionality on the Line Trscv Network Lane <Help> Alarm indicating …
1.3.6.1.4.1.20044.86.2.3.2.192.1.15Columnrm10001wbAlmLineLaneApdPowerSupplyPortnread-onlycurrentLine Network Lane APD Power Supply :This OID indicates an APD Power supply failure on the Line Trscv Network Lane <Help> Alarm indicating an APD Power supply f…
1.3.6.1.4.1.20044.86.2.3.2.192.1.16Columnrm10001wbAlmLineLaneWavelengthUnlockedPortnread-onlycurrentLine Network Lane Wavelength Unlock :This OID indicates a Wavelength unlock on the Line Trscv Network Lane <Help> Alarm indicating a Wavelength unlock on the L…
1.3.6.1.4.1.20044.86.2.3.2.192.1.17Columnrm10001wbAlmLineLaneTecFaultPortnread-onlycurrentLine Network Lane TEC Fault :This OID indicates a Tx TEC Fault on the Line Trscv Network Lane <Help> Alarm indicating a Tx TEC Fault on the Line Trscv Network …
1.3.6.1.4.1.20044.86.2.3.2.196Tablerm10001wbAlmlineHostLaneFaultTablenot-accessiblecurrentList of rm10001wbAlmlineHostLaneFault Article
1.3.6.1.4.1.20044.86.2.3.2.196.1Rowrm10001wbAlmlineHostLaneFaultEntrynot-accessiblecurrentRow definition for the rm10001wbAlmlineHostLaneFault table
1.3.6.1.4.1.20044.86.2.3.2.196.1.1Columnrm10001wbAlmlineHostLaneFaultIndexread-onlycurrentIndex definition for the rm10001wbAlmlineHostLaneFault table
1.3.6.1.4.1.20044.86.2.3.2.196.1.2Columnrm10001wbAlmLineInputLossOfSignalPortnread-onlycurrentLine Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Line Trscv <Help> Alarm indicating a Loss of Signal is detected on the Line T…
1.3.6.1.4.1.20044.86.2.3.2.196.1.3Columnrm10001wbAlmLineLossOfFramePortnread-onlycurrentLine Loss Of Frame :This OID indicates the module is not aligned with the incoming Line signal <Help> Alarm indicating the module is not aligned with the incom…
1.3.6.1.4.1.20044.86.2.3.2.196.1.4Columnrm10001wbAlmLineSmBdiInsertedPortnread-onlycurrentLine SM BDI Inserted :This OID indicates a SM Backward Defect Indication is inserted on the outgoing Line signal <Help> Status indicating a SM Backward Defect …
1.3.6.1.4.1.20044.86.2.3.2.196.1.5Columnrm10001wbAlmLineSmBdiDetectedPortnread-onlycurrentLine SM BDI Detected :This OID indicates a SM Backward Defect Indication is detected on the incoming Line signal <Help> Alarm indicating a SM Backward Defect I…
1.3.6.1.4.1.20044.86.2.3.2.196.1.6Columnrm10001wbAlmLineSmIaeInsertedPortnread-onlycurrentLine SM IAE Inserted :This OID indicates a SM Incoming Alignment Error is inserted on the outgoing Line signal <Help> Status indicating a SM Incoming Alignment…
1.3.6.1.4.1.20044.86.2.3.2.196.1.7Columnrm10001wbAlmLineSmIaeDetectedPortnread-onlycurrentLine SM IAE Detected :This OID indicates a SM Incoming Alignment Error is detected on the incoming Line signal <Help> Alarm indicating a SM Incoming Alignment …
1.3.6.1.4.1.20044.86.2.3.2.196.1.10Columnrm10001wbAlmLineTxHostLolPortnread-onlycurrentLine Host Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Line Trscv Host Lane <Help> Alarm indicating a Tx Loss of Lock on the Line Trscv Ho…
1.3.6.1.4.1.20044.86.2.3.2.196.1.11Columnrm10001wbAlmLineLaneTxFifoErrorPortnread-onlycurrentLine Host Lane Tx FIFO Error :This OID indicates a Tx FIFO Error on the Line Trscv Host Lane <Help> Alarm indicating a Tx FIFO Error on the Line Trscv Host Lan…
1.3.6.1.4.1.20044.86.2.3.2.200Tablerm10001wbAlmlineNetworkLaneRxOtnTablenot-accessiblecurrentList of rm10001wbAlmlineNetworkLaneRxOtn Article
1.3.6.1.4.1.20044.86.2.3.2.200.1Rowrm10001wbAlmlineNetworkLaneRxOtnEntrynot-accessiblecurrentRow definition for the rm10001wbAlmlineNetworkLaneRxOtn table
1.3.6.1.4.1.20044.86.2.3.2.200.1.1Columnrm10001wbAlmlineNetworkLaneRxOtnIndexread-onlycurrentIndex definition for the rm10001wbAlmlineNetworkLaneRxOtn table
1.3.6.1.4.1.20044.86.2.3.2.200.1.10Columnrm10001wbAlmLineRxOtnOduAisPortnread-onlycurrentLine Network Rx ODU AIS :This OID indicates an ODU This OID Indication Signal is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating…
1.3.6.1.4.1.20044.86.2.3.2.200.1.11Columnrm10001wbAlmLineRxOtnOtuAisPortnread-onlycurrentLine Network Rx OTU AIS :This OID indicates an OTU This OID Indication Signal is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating…
1.3.6.1.4.1.20044.86.2.3.2.200.1.12Columnrm10001wbAlmLineRxSmBdiPortnread-onlycurrentLine Network Rx SM BDI :This OID indicates an SM Backward Defect Indication is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating a…
1.3.6.1.4.1.20044.86.2.3.2.200.1.13Columnrm10001wbAlmLineRxOtnIaePortnread-onlycurrentLine Network Rx IAE :This OID indicates an Incoming Alignment Error is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating an Incomi…
1.3.6.1.4.1.20044.86.2.3.2.200.1.14Columnrm10001wbAlmLineRxOtnOomPortnread-onlycurrentLine Network Rx OOM :This OID indicates an Out of Multiframe is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating an Out of Multif…
1.3.6.1.4.1.20044.86.2.3.2.200.1.15Columnrm10001wbAlmLineRxOtnLomPortnread-onlycurrentLine Network Rx LOM :This OID indicates a Loss of Multiframe is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating a Loss of Multif…
1.3.6.1.4.1.20044.86.2.3.2.200.1.16Columnrm10001wbAlmLineRxOtnOofPortnread-onlycurrentLine Network Rx OOF :This OID indicates an Out of Frame is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating an Out of Frame is de…
1.3.6.1.4.1.20044.86.2.3.2.200.1.17Columnrm10001wbAlmLineRxOtnLofPortnread-onlycurrentLine Network Rx LOF :This OID indicates a Loss of Frame is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating a Loss of Frame is de…
1.3.6.1.4.1.20044.86.2.3.2.204Tablerm10001wbAlmlineHostLaneTxOtnTablenot-accessiblecurrentList of rm10001wbAlmlineHostLaneTxOtn Article
1.3.6.1.4.1.20044.86.2.3.2.204.1Rowrm10001wbAlmlineHostLaneTxOtnEntrynot-accessiblecurrentRow definition for the rm10001wbAlmlineHostLaneTxOtn table
1.3.6.1.4.1.20044.86.2.3.2.204.1.1Columnrm10001wbAlmlineHostLaneTxOtnIndexread-onlycurrentIndex definition for the rm10001wbAlmlineHostLaneTxOtn table
1.3.6.1.4.1.20044.86.2.3.2.204.1.10Columnrm10001wbAlmLineTxOtnOduAisPortnread-onlycurrentLine Host Tx ODU AIS :This OID indicates an ODU This OID Indication Signal is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an OD…
1.3.6.1.4.1.20044.86.2.3.2.204.1.11Columnrm10001wbAlmLineTxOtnOtuAisPortnread-onlycurrentLine Host Tx OTU AIS :This OID indicates an OTU This OID Indication Signal is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an OT…
1.3.6.1.4.1.20044.86.2.3.2.204.1.12Columnrm10001wbAlmLineTxSmBdiPortnread-onlycurrentLine Host Tx SM BDI :This OID indicates an SM Backward Defect Indication is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an SM B…
1.3.6.1.4.1.20044.86.2.3.2.204.1.13Columnrm10001wbAlmLineTxOtnIaePortnread-onlycurrentLine Host Tx IAE :This OID indicates an Incoming Alignment Error is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an Incoming Ali…
1.3.6.1.4.1.20044.86.2.3.2.204.1.14Columnrm10001wbAlmLineTxOtnOomPortnread-onlycurrentLine Host Tx OOM :This OID indicates an Out of Multiframe is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an Out of Multiframe i…
1.3.6.1.4.1.20044.86.2.3.2.204.1.15Columnrm10001wbAlmLineTxOtnLomPortnread-onlycurrentLine Host Tx LOM :This OID indicates a Loss of Multiframe is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating a Loss of Multiframe i…
1.3.6.1.4.1.20044.86.2.3.2.204.1.16Columnrm10001wbAlmLineTxOtnOofPortnread-onlycurrentLine Host Tx OOF :This OID indicates an Out of Frame is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an Out of Frame is detected…
1.3.6.1.4.1.20044.86.2.3.2.204.1.17Columnrm10001wbAlmLineTxOtnLofPortnread-onlycurrentLine Host Tx LOF :This OID indicates a Loss of Frame is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating a Loss of Frame is detected…
1.3.6.1.4.1.20044.86.2.3.3Noderm10001wbAlmLineCrit
1.3.6.1.4.1.20044.86.2.3.3.40Tablerm10001wbAlmsynthAlmLineTablenot-accessiblecurrentList of rm10001wbAlmsynthAlmLine Article
1.3.6.1.4.1.20044.86.2.3.3.40.1Rowrm10001wbAlmsynthAlmLineEntrynot-accessiblecurrentRow definition for the rm10001wbAlmsynthAlmLine table
1.3.6.1.4.1.20044.86.2.3.3.40.1.1Columnrm10001wbAlmsynthAlmLineIndexread-onlycurrentIndex definition for the rm10001wbAlmsynthAlmLine table
1.3.6.1.4.1.20044.86.2.3.3.40.1.2Columnrm10001wbAlmXfpAbsentPortnread-onlycurrentLine Optical Module Absent :This OID indicates that the line optical interface is not present. <Help> This alarm indicates if the line transceiver is not plugg…
1.3.6.1.4.1.20044.86.2.3.3.40.1.3Columnrm10001wbAlmXfpInitNotComplPortnread-onlycurrentLine Optical Module Ready :This OID indicates that the optical interface is not operational. <Help> This status indicates if the line transceiver has been corr…
1.3.6.1.4.1.20044.86.2.3.3.40.1.5Columnrm10001wbAlmLineHwFailPortnread-onlycurrentLine Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Help> This alarm indicates a failure on line port, most pr…
1.3.6.1.4.1.20044.86.2.3.3.40.1.6Columnrm10001wbAlmXfpTxOffPortnread-onlycurrentLine Trscv Laser Shutdown :This OID indicates the Line transceiver laser is shutdown <Help> This status indicates if the Line transceiver laser is shutdown <Co…
1.3.6.1.4.1.20044.86.2.3.3.40.1.7Columnrm10001wbAlmLineLocalOosPortnread-onlycurrentLine Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service…
1.3.6.1.4.1.20044.86.2.3.3.40.1.9Columnrm10001wbAlmUpRdiInsPortnread-onlycurrentMS-RDI/L-RDI Inserted On Line :This OID indicates an upstream MS-RDI/L-RDI has been inserted in the outgoing 10 Gb/s SDH/SONET signal. <Help> This status indic…
1.3.6.1.4.1.20044.86.2.3.3.40.1.10Columnrm10001wbAlmLineDdmWarningPortnread-onlycurrentWarning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Warning has…
1.3.6.1.4.1.20044.86.2.3.3.40.1.11Columnrm10001wbAlmLineDdmAlmPortnread-onlycurrentAlarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Alarm has been…
1.3.6.1.4.1.20044.86.2.3.3.40.1.13Columnrm10001wbAlmLineFailPortnread-onlycurrentLine Port Failure :This OID indicates a failure on the line port <Help> This alarm indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipm…
1.3.6.1.4.1.20044.86.2.3.3.40.1.17Columnrm10001wbAlmLineActivePortnread-onlycurrentLine Active :This OID indicates whether the line is active or standby. <Help> This status indicates whether the line is active or standby. <Condtype> LINE_ACTI…
1.3.6.1.4.1.20044.86.3Noderm10001wbmeasures
1.3.6.1.4.1.20044.86.3.1Noderm10001wbMesrOther
1.3.6.1.4.1.20044.86.3.1.0Scalarrm10001wbMesrsynth0read-onlydeprecatedNot Used :
1.3.6.1.4.1.20044.86.3.1.1Scalarrm10001wbMesrsynth1read-onlydeprecatedNot Used :
1.3.6.1.4.1.20044.86.3.1.7Scalarrm10001wbMesrpmIntervalNumberread-onlycurrentPM Interval Counter :
1.3.6.1.4.1.20044.86.3.1.196Scalarrm10001wbMesrlineNetTxLaserOutputPwrAverageread-onlycurrentAverage Line Trscv Tx Power :This OID gives the average Tx Laser transmit power value among the network lanes of the Line Transceiver, read in the DDM (Digital…
1.3.6.1.4.1.20044.86.3.1.197Scalarrm10001wbMesrlineNetTxLaserTempAverageread-onlycurrentAverage Line Trscv Tx Laser Temperature :This OID gives the average Tx Laser Temperature value among the network lanes of the Line Transceiver, read from the D…
1.3.6.1.4.1.20044.86.3.1.198Scalarrm10001wbMesrlineNetTxBiasCurrentAverageread-onlycurrentAverage Line Trscv Tx Laser Bias :This OID gives the average Tx Laser Bias value among the network lanes of the Line Transceiver, read from the DDM (Digital Di…
1.3.6.1.4.1.20044.86.3.1.199Scalarrm10001wbMesrlineNetRxInputPwrAverageread-onlycurrentAverage Line Trscv Rx Power :This OID gives the average Receive power value among the network lanes of the Line Transceiver, read in the DDM (Digital Diagnosti…
1.3.6.1.4.1.20044.86.3.1.200Scalarrm10001wbMesrlineResidualChromaticDispAverageread-onlycurrentAverage Residual Chromatic Dispersion :This OID gives the average Residual Chromatic Dispersion on the Line interface since the last measure reset (Dispersion …
1.3.6.1.4.1.20044.86.3.1.201Scalarrm10001wbMesrlineDiffGroupDelayAverageread-onlycurrentAverage Differential Group Delay :This OID gives the average Group Delay on the Line interface since the last measure reset (Delay = AV_S16) (Unit = ps)<Help> …
1.3.6.1.4.1.20044.86.3.1.202Scalarrm10001wbMesrlineQFactorAverageread-onlycurrentAverage Q Factor :This OID gives the average Q Factor on the Line interface since the last measure reset (Q Factor = AV_U16) (Unit = dB) <Help> This measure gi…
1.3.6.1.4.1.20044.86.3.1.203Scalarrm10001wbMesrlineCarrierFreqOffsetAverageread-onlycurrentAverage Carrier Frequency Offset :This OID gives the average Carrier Frequency Offset on the Line interface since the last measure reset (Offset = AV_S16) (Uni…
1.3.6.1.4.1.20044.86.3.1.204Scalarrm10001wbMesrlineOsnrAverageread-onlycurrentAverage OSNR :This OID gives the average OSNR on the Line interface since the last measure reset (OSNR = AV_S16/10) (Unit = dB)<Help> This measure gives the av…
1.3.6.1.4.1.20044.86.3.1.212Scalarrm10001wbMesrlineNetTxLaserOutputPwrMinread-onlycurrentMin Line Trscv Tx Power :This OID gives the minimum Tx Laser transmit power value among the network lanes of the Line Transceiver, read in the DDM (Digital Dia…
1.3.6.1.4.1.20044.86.3.1.213Scalarrm10001wbMesrlineNetTxLaserTempMinread-onlycurrentMin Line Trscv Tx Laser Temperature :This OID gives the minimum Tx Laser Temperature value among the network lanes of the Line Transceiver, read from the DDM (…
1.3.6.1.4.1.20044.86.3.1.214Scalarrm10001wbMesrlineNetTxBiasCurrentMinread-onlycurrentMin Line Trscv Tx Laser Bias :This OID gives the minimum Tx Laser Bias value among the network lanes of the Line Transceiver, read from the DDM (Digital Diagno…
1.3.6.1.4.1.20044.86.3.1.215Scalarrm10001wbMesrlineNetRxInputPwrMinread-onlycurrentMin Line Trscv Rx Power :This OID gives the minimum Receive power value among the network lanes of the Line Transceiver, read in the DDM (Digital Diagnostic Mo…
1.3.6.1.4.1.20044.86.3.1.216Scalarrm10001wbMesrlineResidualChromaticDispMinread-onlycurrentMin Residual Chromatic Dispersion :This OID gives the minimum Residual Chromatic Dispersion on the Line interface since the last measure reset (Dispersion = AV…
1.3.6.1.4.1.20044.86.3.1.217Scalarrm10001wbMesrlineDiffGroupDelayMinread-onlycurrentMin Differential Group Delay :This OID gives the minimum Differential Group Delay on the Line interface since the last measure reset (Delay = AV_S16) (Unit = p…
1.3.6.1.4.1.20044.86.3.1.218Scalarrm10001wbMesrlineQFactorMinread-onlycurrentMin Q Factor :This OID gives the minimum Q Factor on the Line interface since the last measure reset (Q Factor = AV_U16) (Unit = dB)<Help> This measure gives t…
1.3.6.1.4.1.20044.86.3.1.219Scalarrm10001wbMesrlineCarrierFreqOffsetMinread-onlycurrentMin Carrier Frequency Offset :This OID gives the minimum Carrier Frequency Offset on the Line interface since the last measure reset (Offset = AV_S16) (Unit = …
1.3.6.1.4.1.20044.86.3.1.220Scalarrm10001wbMesrlineOsnrMinread-onlycurrentMin OSNR :This OID gives the minimum OSNR on the Line interface since the last measure reset (OSNR = AV_S16/10) (Unit = dB)<Help> This measure gives the minimu…
1.3.6.1.4.1.20044.86.3.1.228Scalarrm10001wbMesrlineNetTxLaserOutputPwrMaxread-onlycurrentMax Line Trscv Tx Power :This OID gives the maximum Tx Laser transmit power value among the network lanes of the Line Transceiver, read in the DDM (Digital Dia…
1.3.6.1.4.1.20044.86.3.1.229Scalarrm10001wbMesrlineNetTxLaserTempMaxread-onlycurrentMax Line Trscv Tx Laser Temperature :This OID gives the maximum Tx Laser Temperature value among the network lanes of the Line Transceiver, read from the DDM (…
1.3.6.1.4.1.20044.86.3.1.230Scalarrm10001wbMesrlineNetTxBiasCurrentMaxread-onlycurrentMax Line Trscv Tx Laser Bias :This OID gives the maximum Tx Laser Bias value among the network lanes of the Line Transceiver, read from the DDM (Digital Diagno…
1.3.6.1.4.1.20044.86.3.1.231Scalarrm10001wbMesrlineNetRxInputPwrMaxread-onlycurrentMax Line Trscv Rx Power :This OID gives the maximum Receive power value among the network lanes of the Line Transceiver, read in the DDM (Digital Diagnostic Mo…
1.3.6.1.4.1.20044.86.3.1.232Scalarrm10001wbMesrlineResidualChromaticDispMaxread-onlycurrentMax Residual Chromatic Dispersion :This OID gives the maximum Residual Chromatic Dispersion on the Line interface since the last measure reset (Dispersion = AV…
1.3.6.1.4.1.20044.86.3.1.233Scalarrm10001wbMesrlineDiffGroupDelayMaxread-onlycurrentMax Differential Group Delay :This OID gives the maximum Differential Group Delay on the Line interface since the last measure reset (Delay = AV_S16) (Unit = p…
1.3.6.1.4.1.20044.86.3.1.234Scalarrm10001wbMesrlineQFactorMaxread-onlycurrentMax Q Factor :This OID gives the maximum Q Factor on the Line interface since the last measure reset (Q Factor = AV_U16) (Unit = dB)<Help> This measure gives t…
1.3.6.1.4.1.20044.86.3.1.235Scalarrm10001wbMesrlineCarrierFreqOffsetMaxread-onlycurrentMax Carrier Frequency Offset :This OID gives the maximum Carrier Frequency Offset on the Line interface since the last measure reset (Offset = AV_S16) (Unit = …
1.3.6.1.4.1.20044.86.3.1.236Scalarrm10001wbMesrlineOsnrMaxread-onlycurrentMax OSNR :This OID gives the maximum OSNR on the Line interface since the last measure reset (OSNR = AV_S16/10) (Unit = dB)<Help> This measure gives the maximu…
1.3.6.1.4.1.20044.86.3.1.249Scalarrm10001wbMesrregVoltageread-onlycurrentRegulator Voltage :This OID gives the voltage value of the Regulator (Voltage = AV_U16) (Unit = mV) <Help> This Measure gives the Regulator Voltage
1.3.6.1.4.1.20044.86.3.1.250Scalarrm10001wbMesrregCurrentread-onlycurrentRegulator Current :This OID gives the current value of the Regulator (Current = AV_U16/1000) (Unit = A) <Help> This Measure gives the Regulator Current
1.3.6.1.4.1.20044.86.3.1.251Scalarrm10001wbMesrregTempread-onlycurrentRegulator Temperature :This OID gives the temperature value of the Regulator (Temperature = AV_S16) (Unit = C) <Help> This Measure gives the Regulator Temperat…
1.3.6.1.4.1.20044.86.3.1.252Scalarrm10001wbMesrtrscv1Tempread-onlycurrentQ1 Trscv Temperature :This OID gives the temperature value of the Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV_S16/256) (Un…
1.3.6.1.4.1.20044.86.3.1.253Scalarrm10001wbMesrtrscv2Tempread-onlycurrentQ2 Trscv Temperature :This OID gives the temperature value of the Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV_S16/256) (Un…
1.3.6.1.4.1.20044.86.3.1.254Scalarrm10001wbMesrtrscv1PowerSupplyread-onlycurrentQ1 Trscv Voltage :This OID gives the voltage value of the QSFP plugged into the port, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV_U16/10000…
1.3.6.1.4.1.20044.86.3.1.255Scalarrm10001wbMesrtrscv2PowerSupplyread-onlycurrentQ2 Trscv Voltage :This OID gives the voltage value of the QSFP plugged into the port, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV_U16/10000…
1.3.6.1.4.1.20044.86.3.2Noderm10001wbMesrClient
1.3.6.1.4.1.20044.86.3.2.8Scalarrm10001wbMesrclientCfpTempread-onlycurrentClient Trscv Temperature :This OID gives the temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV_S…
1.3.6.1.4.1.20044.86.3.2.9Scalarrm10001wbMesrclientCfp3v3Voltageread-onlycurrentClient Trscv Voltage :This OID gives the 3V3 voltage value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV_U16/10000…
1.3.6.1.4.1.20044.86.3.2.10Scalarrm10001wbMesrclientSoaBiasCurrentread-onlycurrentClient Trscv SOA Bias :This OID gives the SOA bias value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV_U16/500) (Unit…
1.3.6.1.4.1.20044.86.3.2.16Tablerm10001wbMesrclientTxPwrMinTablenot-accessiblecurrentList of rm10001wbMesrclientTxPwrMin Article
1.3.6.1.4.1.20044.86.3.2.16.1Rowrm10001wbMesrclientTxPwrMinEntrynot-accessiblecurrentRow definition for the rm10001wbMesrclientTxPwrMin table
1.3.6.1.4.1.20044.86.3.2.16.1.1Columnrm10001wbMesrclientTxPwrMinIndexread-onlycurrentIndex definition for the rm10001wbMesrclientTxPwrMin table
1.3.6.1.4.1.20044.86.3.2.16.1.2Columnrm10001wbMesrclientTxPwrMinPortnread-onlycurrentMin Client Trscv Tx Power Per Lane :This OID gives the minimum transmit power value among the network lanes of the Client Transceiver, read from the DDM (Digit…
1.3.6.1.4.1.20044.86.3.2.48Tablerm10001wbMesrclientRxPwrMinTablenot-accessiblecurrentList of rm10001wbMesrclientRxPwrMin Article
1.3.6.1.4.1.20044.86.3.2.48.1Rowrm10001wbMesrclientRxPwrMinEntrynot-accessiblecurrentRow definition for the rm10001wbMesrclientRxPwrMin table
1.3.6.1.4.1.20044.86.3.2.48.1.1Columnrm10001wbMesrclientRxPwrMinIndexread-onlycurrentIndex definition for the rm10001wbMesrclientRxPwrMin table
1.3.6.1.4.1.20044.86.3.2.48.1.2Columnrm10001wbMesrclientRxPwrMinPortnread-onlycurrentMin Client Trscv Rx Power Per Lane :This OID gives the minimum receive power value among the network lanes of the Client Transceiver, read from the DDM (Digita…
1.3.6.1.4.1.20044.86.3.2.80Tablerm10001wbMesrclientTxPwrMaxTablenot-accessiblecurrentList of rm10001wbMesrclientTxPwrMax Article
1.3.6.1.4.1.20044.86.3.2.80.1Rowrm10001wbMesrclientTxPwrMaxEntrynot-accessiblecurrentRow definition for the rm10001wbMesrclientTxPwrMax table
1.3.6.1.4.1.20044.86.3.2.80.1.1Columnrm10001wbMesrclientTxPwrMaxIndexread-onlycurrentIndex definition for the rm10001wbMesrclientTxPwrMax table
1.3.6.1.4.1.20044.86.3.2.80.1.2Columnrm10001wbMesrclientTxPwrMaxPortnread-onlycurrentMax Client Trscv Tx Power Per Lane :This OID gives the maximum transmit power value among the network lanes of the Client Transceiver, read from the DDM (Digit…
1.3.6.1.4.1.20044.86.3.2.112Tablerm10001wbMesrclientRxPwrMaxTablenot-accessiblecurrentList of rm10001wbMesrclientRxPwrMax Article
1.3.6.1.4.1.20044.86.3.2.112.1Rowrm10001wbMesrclientRxPwrMaxEntrynot-accessiblecurrentRow definition for the rm10001wbMesrclientRxPwrMax table
1.3.6.1.4.1.20044.86.3.2.112.1.1Columnrm10001wbMesrclientRxPwrMaxIndexread-onlycurrentIndex definition for the rm10001wbMesrclientRxPwrMax table
1.3.6.1.4.1.20044.86.3.2.112.1.2Columnrm10001wbMesrclientRxPwrMaxPortnread-onlycurrentMax Client Trscv Rx Power Per Lane :This OID gives the maximum receive power value among the network lanes of the Client Transceiver, read in the DDM (Digital …
1.3.6.1.4.1.20044.86.3.2.256Tablerm10001wbMesrclientTxCompositePwrTablenot-accessiblecurrentList of rm10001wbMesrclientTxCompositePwr Article
1.3.6.1.4.1.20044.86.3.2.256.1Rowrm10001wbMesrclientTxCompositePwrEntrynot-accessiblecurrentRow definition for the rm10001wbMesrclientTxCompositePwr table
1.3.6.1.4.1.20044.86.3.2.256.1.1Columnrm10001wbMesrclientTxCompositePwrIndexread-onlycurrentIndex definition for the rm10001wbMesrclientTxCompositePwr table
1.3.6.1.4.1.20044.86.3.2.256.1.2Columnrm10001wbMesrclientTxCompositePwrPortnread-onlycurrentClient Composite Tx Power (LR4/SR4) :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver, read from…
1.3.6.1.4.1.20044.86.3.2.288Tablerm10001wbMesrclientRxCompositePwrTablenot-accessiblecurrentList of rm10001wbMesrclientRxCompositePwr Article
1.3.6.1.4.1.20044.86.3.2.288.1Rowrm10001wbMesrclientRxCompositePwrEntrynot-accessiblecurrentRow definition for the rm10001wbMesrclientRxCompositePwr table
1.3.6.1.4.1.20044.86.3.2.288.1.1Columnrm10001wbMesrclientRxCompositePwrIndexread-onlycurrentIndex definition for the rm10001wbMesrclientRxCompositePwr table
1.3.6.1.4.1.20044.86.3.2.288.1.2Columnrm10001wbMesrclientRxCompositePwrPortnread-onlycurrentClient Composite Rx Power (LR4/SR4) :This OID gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver, read from t…
1.3.6.1.4.1.20044.86.3.3Noderm10001wbMesrLine
1.3.6.1.4.1.20044.86.3.3.12Scalarrm10001wbMesrlineMsaTempread-onlycurrentLine Trscv Temperature :This OID gives the temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV_S16/2…
1.3.6.1.4.1.20044.86.3.3.13Scalarrm10001wbMesrlineMsa3v3Voltageread-onlycurrentLine Trscv Voltage :This OID gives the 3V3 voltage value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV_U16/10000) (U…
1.3.6.1.4.1.20044.86.3.3.14Scalarrm10001wbMesrlineSoaBiasCurrentread-onlycurrentLine Trscv SOA Bias :This OID gives the SOA bias value of the Line Transceiver,read from the DDM (Digital Diagnostic Monitoring) (Bias = AV_U16/500) (Unit = mA…
1.3.6.1.4.1.20044.86.3.3.144Tablerm10001wbMesrlineNetTxLaserOutputPwrTablenot-accessiblecurrentList of rm10001wbMesrlineNetTxLaserOutputPwr Article
1.3.6.1.4.1.20044.86.3.3.144.1Rowrm10001wbMesrlineNetTxLaserOutputPwrEntrynot-accessiblecurrentRow definition for the rm10001wbMesrlineNetTxLaserOutputPwr table
1.3.6.1.4.1.20044.86.3.3.144.1.1Columnrm10001wbMesrlineNetTxLaserOutputPwrIndexread-onlycurrentIndex definition for the rm10001wbMesrlineNetTxLaserOutputPwr table
1.3.6.1.4.1.20044.86.3.3.144.1.2Columnrm10001wbMesrlineNetTxLaserOutputPwrPortnread-onlycurrentCurrent Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power =…
1.3.6.1.4.1.20044.86.3.3.148Tablerm10001wbMesrlineNetTxLaserTempTablenot-accessiblecurrentList of rm10001wbMesrlineNetTxLaserTemp Article
1.3.6.1.4.1.20044.86.3.3.148.1Rowrm10001wbMesrlineNetTxLaserTempEntrynot-accessiblecurrentRow definition for the rm10001wbMesrlineNetTxLaserTemp table
1.3.6.1.4.1.20044.86.3.3.148.1.1Columnrm10001wbMesrlineNetTxLaserTempIndexread-onlycurrentIndex definition for the rm10001wbMesrlineNetTxLaserTemp table
1.3.6.1.4.1.20044.86.3.3.148.1.2Columnrm10001wbMesrlineNetTxLaserTempPortnread-onlycurrentCurrent Line Trscv Tx Laser Temperature :This OID gives the Tx Laser Temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitorin…
1.3.6.1.4.1.20044.86.3.3.152Tablerm10001wbMesrlineNetTxBiasCurrentTablenot-accessiblecurrentList of rm10001wbMesrlineNetTxBiasCurrent Article
1.3.6.1.4.1.20044.86.3.3.152.1Rowrm10001wbMesrlineNetTxBiasCurrentEntrynot-accessiblecurrentRow definition for the rm10001wbMesrlineNetTxBiasCurrent table
1.3.6.1.4.1.20044.86.3.3.152.1.1Columnrm10001wbMesrlineNetTxBiasCurrentIndexread-onlycurrentIndex definition for the rm10001wbMesrlineNetTxBiasCurrent table
1.3.6.1.4.1.20044.86.3.3.152.1.2Columnrm10001wbMesrlineNetTxBiasCurrentPortnread-onlycurrentCurrent Line Trscv Tx Laser Bias :This OID gives the Tx Laser Bias value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV_…
1.3.6.1.4.1.20044.86.3.3.156Tablerm10001wbMesrlineNetRxInputPwrTablenot-accessiblecurrentList of rm10001wbMesrlineNetRxInputPwr Article
1.3.6.1.4.1.20044.86.3.3.156.1Rowrm10001wbMesrlineNetRxInputPwrEntrynot-accessiblecurrentRow definition for the rm10001wbMesrlineNetRxInputPwr table
1.3.6.1.4.1.20044.86.3.3.156.1.1Columnrm10001wbMesrlineNetRxInputPwrIndexread-onlycurrentIndex definition for the rm10001wbMesrlineNetRxInputPwr table
1.3.6.1.4.1.20044.86.3.3.156.1.2Columnrm10001wbMesrlineNetRxInputPwrPortnread-onlycurrentCurrent Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/10…
1.3.6.1.4.1.20044.86.3.3.160Tablerm10001wbMesrlineResidualChromaticDispTablenot-accessiblecurrentList of rm10001wbMesrlineResidualChromaticDisp Article
1.3.6.1.4.1.20044.86.3.3.160.1Rowrm10001wbMesrlineResidualChromaticDispEntrynot-accessiblecurrentRow definition for the rm10001wbMesrlineResidualChromaticDisp table
1.3.6.1.4.1.20044.86.3.3.160.1.1Columnrm10001wbMesrlineResidualChromaticDispIndexread-onlycurrentIndex definition for the rm10001wbMesrlineResidualChromaticDisp table
1.3.6.1.4.1.20044.86.3.3.160.1.2Columnrm10001wbMesrlineResidualChromaticDispPortnread-onlycurrentCurrent Residual Chromatic Dispersion :This OID gives the current Residual Chromatic Dispersion on the Line interface (Dispersion = AV_S16*(-2)) (Unit = ps/nm)…
1.3.6.1.4.1.20044.86.3.3.164Tablerm10001wbMesrlineDiffGroupDelayTablenot-accessiblecurrentList of rm10001wbMesrlineDiffGroupDelay Article
1.3.6.1.4.1.20044.86.3.3.164.1Rowrm10001wbMesrlineDiffGroupDelayEntrynot-accessiblecurrentRow definition for the rm10001wbMesrlineDiffGroupDelay table
1.3.6.1.4.1.20044.86.3.3.164.1.1Columnrm10001wbMesrlineDiffGroupDelayIndexread-onlycurrentIndex definition for the rm10001wbMesrlineDiffGroupDelay table
1.3.6.1.4.1.20044.86.3.3.164.1.2Columnrm10001wbMesrlineDiffGroupDelayPortnread-onlycurrentCurrent Differential Group Delay :This OID gives the current Differential Group Delay on the Line interface (Delay = AV_S16) (Unit = ps)<Help> This measure giv…
1.3.6.1.4.1.20044.86.3.3.168Tablerm10001wbMesrlineQFactorTablenot-accessiblecurrentList of rm10001wbMesrlineQFactor Article
1.3.6.1.4.1.20044.86.3.3.168.1Rowrm10001wbMesrlineQFactorEntrynot-accessiblecurrentRow definition for the rm10001wbMesrlineQFactor table
1.3.6.1.4.1.20044.86.3.3.168.1.1Columnrm10001wbMesrlineQFactorIndexread-onlycurrentIndex definition for the rm10001wbMesrlineQFactor table
1.3.6.1.4.1.20044.86.3.3.168.1.2Columnrm10001wbMesrlineQFactorPortnread-onlycurrentCurrent Q Factor :This OID gives the current Q Factor on the Line interface (Q Factor = AV_U16) (Unit = dB) <Help> This measure gives the current Q Factor on t…
1.3.6.1.4.1.20044.86.3.3.172Tablerm10001wbMesrlineCarrierFreqOffsetTablenot-accessiblecurrentList of rm10001wbMesrlineCarrierFreqOffset Article
1.3.6.1.4.1.20044.86.3.3.172.1Rowrm10001wbMesrlineCarrierFreqOffsetEntrynot-accessiblecurrentRow definition for the rm10001wbMesrlineCarrierFreqOffset table
1.3.6.1.4.1.20044.86.3.3.172.1.1Columnrm10001wbMesrlineCarrierFreqOffsetIndexread-onlycurrentIndex definition for the rm10001wbMesrlineCarrierFreqOffset table
1.3.6.1.4.1.20044.86.3.3.172.1.2Columnrm10001wbMesrlineCarrierFreqOffsetPortnread-onlycurrentCurrent Carrier Frequency Offset :This OID gives the current Carrier Frequency Offset on the Line interface (Offset = AV_S16) (Unit = MHz)<Help> This measure g…
1.3.6.1.4.1.20044.86.3.3.176Tablerm10001wbMesrlineOsnrTablenot-accessiblecurrentList of rm10001wbMesrlineOsnr Article
1.3.6.1.4.1.20044.86.3.3.176.1Rowrm10001wbMesrlineOsnrEntrynot-accessiblecurrentRow definition for the rm10001wbMesrlineOsnr table
1.3.6.1.4.1.20044.86.3.3.176.1.1Columnrm10001wbMesrlineOsnrIndexread-onlycurrentIndex definition for the rm10001wbMesrlineOsnr table
1.3.6.1.4.1.20044.86.3.3.176.1.2Columnrm10001wbMesrlineOsnrPortnread-onlycurrentCurrent OSNR :This OID gives the current OSNR on the Line interface (OSNR = AV_S16/10) (Unit = dB)<Help> This measure gives the current OSNR on the Line interf…
1.3.6.1.4.1.20044.86.4Noderm10001wbcounters
1.3.6.1.4.1.20044.86.4.1Noderm10001wbCntOther
1.3.6.1.4.1.20044.86.4.2Noderm10001wbCntClient
1.3.6.1.4.1.20044.86.4.2.112Tablerm10001wbCntclientInputErrorCounterTablenot-accessiblecurrentList of rm10001wbCntclientInputErrorCounter Article
1.3.6.1.4.1.20044.86.4.2.112.1Rowrm10001wbCntclientInputErrorCounterEntrynot-accessiblecurrentRow definition for the rm10001wbCntclientInputErrorCounter table
1.3.6.1.4.1.20044.86.4.2.112.1.1Columnrm10001wbCntclientInputErrorCounterIndexread-onlycurrentIndex definition for the rm10001wbCntclientInputErrorCounter table
1.3.6.1.4.1.20044.86.4.2.112.1.2Columnrm10001wbCntclientInputErrorCounterValuePortnread-onlycurrentClient Input Errors :This counter is increased each time a 10b/8b running disparity error is detected on the Client input stream <Help> This counter gives the …
1.3.6.1.4.1.20044.86.4.2.112.1.3Columnrm10001wbCntclientInputErrorCounterErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the client error counter value is invalid on Port
1.3.6.1.4.1.20044.86.4.2.112.1.4Columnrm10001wbCntclientInputErrorCounterOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a client input error counter overload on Port
1.3.6.1.4.1.20044.86.4.2.144Tablerm10001wbCntclientCbipCounterTablenot-accessiblecurrentList of rm10001wbCntclientCbipCounter Article
1.3.6.1.4.1.20044.86.4.2.144.1Rowrm10001wbCntclientCbipCounterEntrynot-accessiblecurrentRow definition for the rm10001wbCntclientCbipCounter table
1.3.6.1.4.1.20044.86.4.2.144.1.1Columnrm10001wbCntclientCbipCounterIndexread-onlycurrentIndex definition for the rm10001wbCntclientCbipCounter table
1.3.6.1.4.1.20044.86.4.2.144.1.2Columnrm10001wbCntclientCbipCounterValuePortnread-onlycurrentClient Output Errors :This counter is incremented each time a CBIP parity error is detected on the Client output stream <Help> This counter gives the number of…
1.3.6.1.4.1.20044.86.4.2.144.1.3Columnrm10001wbCntclientCbipCounterErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the CBIP error counter value is invalid on Port
1.3.6.1.4.1.20044.86.4.2.144.1.4Columnrm10001wbCntclientCbipCounterOverloadPortnread-onlycurrentClient CBIP Counter Overload :This OID when set indicates a CBIP error counter overload on Port
1.3.6.1.4.1.20044.86.4.3Noderm10001wbCntLine
1.3.6.1.4.1.20044.86.4.3.192Tablerm10001wbCntlocalLineSmBip8ErrorCounterTablenot-accessiblecurrentList of rm10001wbCntlocalLineSmBip8ErrorCounter Article
1.3.6.1.4.1.20044.86.4.3.192.1Rowrm10001wbCntlocalLineSmBip8ErrorCounterEntrynot-accessiblecurrentRow definition for the rm10001wbCntlocalLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.86.4.3.192.1.1Columnrm10001wbCntlocalLineSmBip8ErrorCounterIndexread-onlycurrentIndex definition for the rm10001wbCntlocalLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.86.4.3.192.1.2Columnrm10001wbCntlocalLineSmBip8ErrorCounterValuePortnread-onlycurrentUncorrected FEC Errors :This OID gives the current Bit Error Rate after the Soft Decision FEC (residual) <Help> This counter gives the current Bit Error Rate a…
1.3.6.1.4.1.20044.86.4.3.192.1.3Columnrm10001wbCntlocalLineSmBip8ErrorCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.86.4.3.192.1.4Columnrm10001wbCntlocalLineSmBip8ErrorCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.86.4.3.193Tablerm10001wbCntlocalLineFecCorrectedErrorsCounterTablenot-accessiblecurrentList of rm10001wbCntlocalLineFecCorrectedErrorsCounter Article
1.3.6.1.4.1.20044.86.4.3.193.1Rowrm10001wbCntlocalLineFecCorrectedErrorsCounterEntrynot-accessiblecurrentRow definition for the rm10001wbCntlocalLineFecCorrectedErrorsCounter table
1.3.6.1.4.1.20044.86.4.3.193.1.1Columnrm10001wbCntlocalLineFecCorrectedErrorsCounterIndexread-onlycurrentIndex definition for the rm10001wbCntlocalLineFecCorrectedErrorsCounter table
1.3.6.1.4.1.20044.86.4.3.193.1.2Columnrm10001wbCntlocalLineFecCorrectedErrorsCounterValuePortnread-onlycurrentLine Input HD FEC Corrected Errors :This OID gives the current Bit Error Rate before the Hard Decision FEC <Help> This counter gives the current Bit Error Rate…
1.3.6.1.4.1.20044.86.4.3.193.1.3Columnrm10001wbCntlocalLineFecCorrectedErrorsCounterErrorPortnread-onlycurrentFEC Counter Error :This bit when set indicates the FEC corrected errors counter value is invalid on Line
1.3.6.1.4.1.20044.86.4.3.193.1.4Columnrm10001wbCntlocalLineFecCorrectedErrorsCounterOverloadPortnread-onlycurrentFEC Counter Overload :This bit when set indicates a FEC corrected errors counter overload on Line
1.3.6.1.4.1.20044.86.4.3.194Tablerm10001wbCntremoteLineSmBip8ErrorCounterTablenot-accessiblecurrentList of rm10001wbCntremoteLineSmBip8ErrorCounter Article
1.3.6.1.4.1.20044.86.4.3.194.1Rowrm10001wbCntremoteLineSmBip8ErrorCounterEntrynot-accessiblecurrentRow definition for the rm10001wbCntremoteLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.86.4.3.194.1.1Columnrm10001wbCntremoteLineSmBip8ErrorCounterIndexread-onlycurrentIndex definition for the rm10001wbCntremoteLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.86.4.3.194.1.2Columnrm10001wbCntremoteLineSmBip8ErrorCounterValuePortnread-onlycurrentRemote SM BIP8 :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC on the remote side <Help> This counter gives the current Bit Error…
1.3.6.1.4.1.20044.86.4.3.194.1.3Columnrm10001wbCntremoteLineSmBip8ErrorCounterErrorPortnread-onlycurrentRemote Counter Error :
1.3.6.1.4.1.20044.86.4.3.194.1.4Columnrm10001wbCntremoteLineSmBip8ErrorCounterOverloadPortnread-onlycurrentRemote Counter Overload :
1.3.6.1.4.1.20044.86.4.3.195Tablerm10001wbCntlineDfrmTimCntTablenot-accessiblecurrentList of rm10001wbCntlineDfrmTimCnt Article
1.3.6.1.4.1.20044.86.4.3.195.1Rowrm10001wbCntlineDfrmTimCntEntrynot-accessiblecurrentRow definition for the rm10001wbCntlineDfrmTimCnt table
1.3.6.1.4.1.20044.86.4.3.195.1.1Columnrm10001wbCntlineDfrmTimCntIndexread-onlycurrentIndex definition for the rm10001wbCntlineDfrmTimCnt table
1.3.6.1.4.1.20044.86.4.3.195.1.2Columnrm10001wbCntlineDfrmTimCntValuePortnread-onlycurrentLine Timer Counter :
1.3.6.1.4.1.20044.86.4.3.195.1.3Columnrm10001wbCntlineDfrmTimCntErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.86.4.3.195.1.4Columnrm10001wbCntlineDfrmTimCntOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.86.4.3.196Tablerm10001wbCntlocalLineTrscvPreSdFecErrorCounterTablenot-accessiblecurrentList of rm10001wbCntlocalLineTrscvPreSdFecErrorCounter Article
1.3.6.1.4.1.20044.86.4.3.196.1Rowrm10001wbCntlocalLineTrscvPreSdFecErrorCounterEntrynot-accessiblecurrentRow definition for the rm10001wbCntlocalLineTrscvPreSdFecErrorCounter table
1.3.6.1.4.1.20044.86.4.3.196.1.1Columnrm10001wbCntlocalLineTrscvPreSdFecErrorCounterIndexread-onlycurrentIndex definition for the rm10001wbCntlocalLineTrscvPreSdFecErrorCounter table
1.3.6.1.4.1.20044.86.4.3.196.1.2Columnrm10001wbCntlocalLineTrscvPreSdFecErrorCounterValuePortnread-onlycurrentPre FEC Errors :This OID gives the current Bit Error Rate before the FEC <Help> This counter gives the current Bit Error Rate before the FEC
1.3.6.1.4.1.20044.86.4.3.196.1.3Columnrm10001wbCntlocalLineTrscvPreSdFecErrorCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.86.4.3.196.1.4Columnrm10001wbCntlocalLineTrscvPreSdFecErrorCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.86.4.3.197Tablerm10001wbCntlocalLineTrscvUncorrectedSdFecErrorCounterTablenot-accessiblecurrentList of rm10001wbCntlocalLineTrscvUncorrectedSdFecErrorCounter Article
1.3.6.1.4.1.20044.86.4.3.197.1Rowrm10001wbCntlocalLineTrscvUncorrectedSdFecErrorCounterEntrynot-accessiblecurrentRow definition for the rm10001wbCntlocalLineTrscvUncorrectedSdFecErrorCounter table
1.3.6.1.4.1.20044.86.4.3.197.1.1Columnrm10001wbCntlocalLineTrscvUncorrectedSdFecErrorCounterIndexread-onlycurrentIndex definition for the rm10001wbCntlocalLineTrscvUncorrectedSdFecErrorCounter table
1.3.6.1.4.1.20044.86.4.3.197.1.2Columnrm10001wbCntlocalLineTrscvUncorrectedSdFecErrorCounterValuePortnread-onlycurrentUncorrected FEC Errors :This OID gives the current Bit Error Rate after the Soft Decision FEC (residual) <Help> This counter gives the current Bit Error Rate a…
1.3.6.1.4.1.20044.86.4.3.197.1.3Columnrm10001wbCntlocalLineTrscvUncorrectedSdFecErrorCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.86.4.3.197.1.4Columnrm10001wbCntlocalLineTrscvUncorrectedSdFecErrorCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.86.4.3.198Tablerm10001wbCntlocalLineTrscvPreSdFecBitCounterTablenot-accessiblecurrentList of rm10001wbCntlocalLineTrscvPreSdFecBitCounter Article
1.3.6.1.4.1.20044.86.4.3.198.1Rowrm10001wbCntlocalLineTrscvPreSdFecBitCounterEntrynot-accessiblecurrentRow definition for the rm10001wbCntlocalLineTrscvPreSdFecBitCounter table
1.3.6.1.4.1.20044.86.4.3.198.1.1Columnrm10001wbCntlocalLineTrscvPreSdFecBitCounterIndexread-onlycurrentIndex definition for the rm10001wbCntlocalLineTrscvPreSdFecBitCounter table
1.3.6.1.4.1.20044.86.4.3.198.1.2Columnrm10001wbCntlocalLineTrscvPreSdFecBitCounterValuePortnread-onlycurrentPre-SD FEC Bit Counter :This OID gives the current Bit count before the Soft Decision FEC <Help> This counter gives the current Bit Count before the Soft Decis…
1.3.6.1.4.1.20044.86.4.3.198.1.3Columnrm10001wbCntlocalLineTrscvPreSdFecBitCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.86.4.3.198.1.4Columnrm10001wbCntlocalLineTrscvPreSdFecBitCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.86.4.3.199Tablerm10001wbCntlocalLineTrscvUncorrectedSdFecBitCounterTablenot-accessiblecurrentList of rm10001wbCntlocalLineTrscvUncorrectedSdFecBitCounter Article
1.3.6.1.4.1.20044.86.4.3.199.1Rowrm10001wbCntlocalLineTrscvUncorrectedSdFecBitCounterEntrynot-accessiblecurrentRow definition for the rm10001wbCntlocalLineTrscvUncorrectedSdFecBitCounter table
1.3.6.1.4.1.20044.86.4.3.199.1.1Columnrm10001wbCntlocalLineTrscvUncorrectedSdFecBitCounterIndexread-onlycurrentIndex definition for the rm10001wbCntlocalLineTrscvUncorrectedSdFecBitCounter table
1.3.6.1.4.1.20044.86.4.3.199.1.2Columnrm10001wbCntlocalLineTrscvUncorrectedSdFecBitCounterValuePortnread-onlycurrentUncorrected SD FEC Bit Counter :This OID gives the current Bit count after the Soft Decision FEC (residual) <Help> This counter gives the current Bit Count aft…
1.3.6.1.4.1.20044.86.4.3.199.1.3Columnrm10001wbCntlocalLineTrscvUncorrectedSdFecBitCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.86.4.3.199.1.4Columnrm10001wbCntlocalLineTrscvUncorrectedSdFecBitCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.86.6Noderm10001wbcontrolsWrite
1.3.6.1.4.1.20044.86.6.1Noderm10001wbCtrlOther
1.3.6.1.4.1.20044.86.6.1.1Noderm10001wbCtrlconfMgnt1
1.3.6.1.4.1.20044.86.6.1.1.1Scalarrm10001wbCtrlConf1Load1read-writecurrentLoad Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM.
1.3.6.1.4.1.20044.86.6.1.1.2Scalarrm10001wbCtrlConf2Load1read-writecurrentLoad Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM.
1.3.6.1.4.1.20044.86.6.1.1.10Scalarrm10001wbCtrlConf2Flash1read-writecurrentWrite Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura…
1.3.6.1.4.1.20044.86.6.1.1.14Scalarrm10001wbCtrlConf2Clear1read-writecurrentClear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o…
1.3.6.1.4.1.20044.86.6.1.4Noderm10001wbCtrlsynth4
1.3.6.1.4.1.20044.86.6.1.4.1Scalarrm10001wbCtrlCorrelatOnread-writecurrentEnable Alarm Correlation :This OID enables the alarm correlation in the PM.
1.3.6.1.4.1.20044.86.6.1.4.2Scalarrm10001wbCtrlCorrelatOffread-writecurrentDisable Alarm Correlation :This OID disables the alarm correlation in the PM.
1.3.6.1.4.1.20044.86.6.1.5Noderm10001wbCtrlswMgnt
1.3.6.1.4.1.20044.86.6.1.5.2Scalarrm10001wbCtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> …
1.3.6.1.4.1.20044.86.6.1.5.3Scalarrm10001wbCtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th…
1.3.6.1.4.1.20044.86.6.1.5.5Scalarrm10001wbCtrlLoadSwBank1read-writecurrentSet Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW…
1.3.6.1.4.1.20044.86.6.1.5.6Scalarrm10001wbCtrlLoadSwBank2read-writecurrentSet Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S…
1.3.6.1.4.1.20044.86.6.1.6Noderm10001wbCtrlgwMgnt
1.3.6.1.4.1.20044.86.6.1.6.1Scalarrm10001wbCtrlCurrentGwResetread-writecurrentActive Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting.
1.3.6.1.4.1.20044.86.6.1.6.5Scalarrm10001wbCtrlLoadGwBank1read-writecurrentSet Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.86.6.1.6.6Scalarrm10001wbCtrlLoadGwBank2read-writecurrentSet Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.86.6.1.6.7Scalarrm10001wbCtrlLoadGwBank3read-writecurrentSet Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.86.6.1.6.8Scalarrm10001wbCtrlLoadGwBank4read-writecurrentSet Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.86.6.1.192Noderm10001wbCtrlledTest
1.3.6.1.4.1.20044.86.6.1.192.1Scalarrm10001wbCtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.86.6.1.192.2Scalarrm10001wbCtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.86.6.1.192.3Scalarrm10001wbCtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.86.6.1.201Noderm10001wbCtrlinitSwitchMarvell
1.3.6.1.4.1.20044.86.6.1.201.1Scalarrm10001wbCtrlInitSwitchMarvellread-writecurrentSwitch Initialization :This OID operates an initialization of the switch managed through the module <Help> This control activates an initialization of the swit…
1.3.6.1.4.1.20044.86.6.1.259Noderm10001wbCtrlresetCount
1.3.6.1.4.1.20044.86.6.1.259.1Scalarrm10001wbCtrlResetcountread-writecurrentModule Count Global Reset :This OID resets all the errors counters on the module <Help > This control initiates a reset of the errors counters on the module
1.3.6.1.4.1.20044.86.6.1.260Noderm10001wbCtrlresetRmon
1.3.6.1.4.1.20044.86.6.1.260.1Scalarrm10001wbCtrlResetrmonread-writecurrentModule Rmon Global Reset :This OID resets all the Rmon counters on the module <Help > This control initiates a reset of the Rmon counters on the module
1.3.6.1.4.1.20044.86.6.1.261Noderm10001wbCtrlresetMeasurements
1.3.6.1.4.1.20044.86.6.1.261.1Scalarrm10001wbCtrlResetmeasurementsread-writecurrentManagement Meas Global Reset :This OID resets some measurements on the management <Help > This control initiates a reset of some measurements on the management
1.3.6.1.4.1.20044.86.6.2Noderm10001wbCtrlClient
1.3.6.1.4.1.20044.86.6.2.16Tablerm10001wbCtrlaccessLoopTablenot-accessiblecurrentList of rm10001wbCtrlaccessLoop Article
1.3.6.1.4.1.20044.86.6.2.16.1Rowrm10001wbCtrlaccessLoopEntrynot-accessiblecurrentRow definition for the rm10001wbCtrlaccessLoop table
1.3.6.1.4.1.20044.86.6.2.16.1.1Columnrm10001wbCtrlaccessLoopIndexread-onlycurrentIndex definition for the rm10001wbCtrlaccessLoop table
1.3.6.1.4.1.20044.86.6.2.16.1.2Columnrm10001wbCtrlaccessLoopPortnread-writecurrentClient Facility Loopback :This OID, when set at '1' puts the client port in loopback, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. <Help…
1.3.6.1.4.1.20044.86.6.2.17Tablerm10001wbCtrlclientLoopToLineTablenot-accessiblecurrentList of rm10001wbCtrlclientLoopToLine Article
1.3.6.1.4.1.20044.86.6.2.17.1Rowrm10001wbCtrlclientLoopToLineEntrynot-accessiblecurrentRow definition for the rm10001wbCtrlclientLoopToLine table
1.3.6.1.4.1.20044.86.6.2.17.1.1Columnrm10001wbCtrlclientLoopToLineIndexread-onlycurrentIndex definition for the rm10001wbCtrlclientLoopToLine table
1.3.6.1.4.1.20044.86.6.2.17.1.2Columnrm10001wbCtrlclientLoopToLinePortnread-writecurrentClient Terminal Loopback :This OID, when set, puts the client port in loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.<Help> This control ena…
1.3.6.1.4.1.20044.86.6.2.21Tablerm10001wbCtrlcsfUpInsTablenot-accessiblecurrentList of rm10001wbCtrlcsfUpIns Article
1.3.6.1.4.1.20044.86.6.2.21.1Rowrm10001wbCtrlcsfUpInsEntrynot-accessiblecurrentRow definition for the rm10001wbCtrlcsfUpIns table
1.3.6.1.4.1.20044.86.6.2.21.1.1Columnrm10001wbCtrlcsfUpInsIndexread-onlycurrentIndex definition for the rm10001wbCtrlcsfUpIns table
1.3.6.1.4.1.20044.86.6.2.21.1.2Columnrm10001wbCtrlcsfUpInsPortnread-writecurrentClient Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo…
1.3.6.1.4.1.20044.86.6.2.22Tablerm10001wbCtrlcaisDwInsTablenot-accessiblecurrentList of rm10001wbCtrlcaisDwIns Article
1.3.6.1.4.1.20044.86.6.2.22.1Rowrm10001wbCtrlcaisDwInsEntrynot-accessiblecurrentRow definition for the rm10001wbCtrlcaisDwIns table
1.3.6.1.4.1.20044.86.6.2.22.1.1Columnrm10001wbCtrlcaisDwInsIndexread-onlycurrentIndex definition for the rm10001wbCtrlcaisDwIns table
1.3.6.1.4.1.20044.86.6.2.22.1.2Columnrm10001wbCtrlcaisDwInsPortnread-writecurrentClient AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port
1.3.6.1.4.1.20044.86.6.2.262Tablerm10001wbCtrlclientResetAllCountTablenot-accessiblecurrentList of rm10001wbCtrlclientResetAllCount Article
1.3.6.1.4.1.20044.86.6.2.262.1Rowrm10001wbCtrlclientResetAllCountEntrynot-accessiblecurrentRow definition for the rm10001wbCtrlclientResetAllCount table
1.3.6.1.4.1.20044.86.6.2.262.1.1Columnrm10001wbCtrlclientResetAllCountIndexread-onlycurrentIndex definition for the rm10001wbCtrlclientResetAllCount table
1.3.6.1.4.1.20044.86.6.2.262.1.2Columnrm10001wbCtrlclientResetAllCountsPortnread-writecurrentClient Counters Reset :This OID resets every counter on the client port <Help> This control operates a reset on the statistics current ,previous and history cl…
1.3.6.1.4.1.20044.86.6.3Noderm10001wbCtrlLine
1.3.6.1.4.1.20044.86.6.3.64Tablerm10001wbCtrlcommAccessLoopTablenot-accessiblecurrentList of rm10001wbCtrlcommAccessLoop Article
1.3.6.1.4.1.20044.86.6.3.64.1Rowrm10001wbCtrlcommAccessLoopEntrynot-accessiblecurrentRow definition for the rm10001wbCtrlcommAccessLoop table
1.3.6.1.4.1.20044.86.6.3.64.1.1Columnrm10001wbCtrlcommAccessLoopIndexread-onlycurrentIndex definition for the rm10001wbCtrlcommAccessLoop table
1.3.6.1.4.1.20044.86.6.3.64.1.2Columnrm10001wbCtrlcommAccessLoopPortnread-writecurrentLine Terminal Loopback :This OID, when set, puts the module in common access loop back, looping the 200 Gb/s output signal on the 200 Gb/s input.<Help> This co…
1.3.6.1.4.1.20044.86.6.3.66Tablerm10001wbCtrllineLoopTablenot-accessiblecurrentList of rm10001wbCtrllineLoop Article
1.3.6.1.4.1.20044.86.6.3.66.1Rowrm10001wbCtrllineLoopEntrynot-accessiblecurrentRow definition for the rm10001wbCtrllineLoop table
1.3.6.1.4.1.20044.86.6.3.66.1.1Columnrm10001wbCtrllineLoopIndexread-onlycurrentIndex definition for the rm10001wbCtrllineLoop table
1.3.6.1.4.1.20044.86.6.3.66.1.2Columnrm10001wbCtrllineLoopPortnread-writecurrentLine Facility Loopback :This OID, when set at '1' puts the module in line loopback mode, looping the received 200 Gb/s signal on the transmit 200 Gb/s output. …
1.3.6.1.4.1.20044.86.6.3.69Tablerm10001wbCtrlfecDisableTablenot-accessiblecurrentList of rm10001wbCtrlfecDisable Article
1.3.6.1.4.1.20044.86.6.3.69.1Rowrm10001wbCtrlfecDisableEntrynot-accessiblecurrentRow definition for the rm10001wbCtrlfecDisable table
1.3.6.1.4.1.20044.86.6.3.69.1.1Columnrm10001wbCtrlfecDisableIndexread-onlycurrentIndex definition for the rm10001wbCtrlfecDisable table
1.3.6.1.4.1.20044.86.6.3.69.1.2Columnrm10001wbCtrlfecDisablePortnread-writecurrentForward Error Correction Inhibition :This OID, when set, inhibits the Forward Error Correction feature on the line input <Help> This control enables/disables t…
1.3.6.1.4.1.20044.86.6.3.209Tablerm10001wbCtrlmsaLineLoopTablenot-accessiblecurrentList of rm10001wbCtrlmsaLineLoop Article
1.3.6.1.4.1.20044.86.6.3.209.1Rowrm10001wbCtrlmsaLineLoopEntrynot-accessiblecurrentRow definition for the rm10001wbCtrlmsaLineLoop table
1.3.6.1.4.1.20044.86.6.3.209.1.1Columnrm10001wbCtrlmsaLineLoopIndexread-onlycurrentIndex definition for the rm10001wbCtrlmsaLineLoop table
1.3.6.1.4.1.20044.86.6.3.209.1.2Columnrm10001wbCtrlmsaLineLoopPortnread-writecurrentMSA Line Loop :This OID operates a line loopback on the MSA Line <Help> This control defines the line loop back of the line transceiver
1.3.6.1.4.1.20044.86.6.3.210Tablerm10001wbCtrlmsaRestartTablenot-accessiblecurrentList of rm10001wbCtrlmsaRestart Article
1.3.6.1.4.1.20044.86.6.3.210.1Rowrm10001wbCtrlmsaRestartEntrynot-accessiblecurrentRow definition for the rm10001wbCtrlmsaRestart table
1.3.6.1.4.1.20044.86.6.3.210.1.1Columnrm10001wbCtrlmsaRestartIndexread-onlycurrentIndex definition for the rm10001wbCtrlmsaRestart table
1.3.6.1.4.1.20044.86.6.3.210.1.2Columnrm10001wbCtrlmsaRestartPortnread-writecurrentForce Line Restart :This OID forces the restart of the line after a shutdown due to Line high temperature<Help> This parameter forces the restart of the line a…
1.3.6.1.4.1.20044.86.6.3.263Tablerm10001wbCtrllineResetAllCountTablenot-accessiblecurrentList of rm10001wbCtrllineResetAllCount Article
1.3.6.1.4.1.20044.86.6.3.263.1Rowrm10001wbCtrllineResetAllCountEntrynot-accessiblecurrentRow definition for the rm10001wbCtrllineResetAllCount table
1.3.6.1.4.1.20044.86.6.3.263.1.1Columnrm10001wbCtrllineResetAllCountIndexread-onlycurrentIndex definition for the rm10001wbCtrllineResetAllCount table
1.3.6.1.4.1.20044.86.6.3.263.1.2Columnrm10001wbCtrllineResetAllCountsPortnread-writecurrentLine Counters Reset :This OID resets every counter on the line port <Help> This control operates a reset on the statistics current ,previous and history line p…
1.3.6.1.4.1.20044.86.7Noderm10001wbri
1.3.6.1.4.1.20044.86.7.1Noderm10001wbriTable
1.3.6.1.4.1.20044.86.7.1.1Tablerm10001wbRinvSfpTablenot-accessiblecurrentList of the SFPs on the selected module
1.3.6.1.4.1.20044.86.7.1.1.1Rowrm10001wbRinvSfpEntrynot-accessiblecurrentRow definition for the SFP table
1.3.6.1.4.1.20044.86.7.1.1.1.1Columnrm10001wbRinvSfpIndexread-onlycurrentIndex for SFP table
1.3.6.1.4.1.20044.86.7.1.1.1.2Columnrm10001wbRinvsfpread-onlycurrentInventory for the SFP: This OID contains the inventory for the SFP
1.3.6.1.4.1.20044.86.7.1.2Tablerm10001wbRinvLineTablenot-accessiblecurrentList of the XFPs on the selected module
1.3.6.1.4.1.20044.86.7.1.2.1Rowrm10001wbRinvLineEntrynot-accessiblecurrentRow definition for the XFP table
1.3.6.1.4.1.20044.86.7.1.2.1.1Columnrm10001wbRinvLineIndexread-onlycurrentIndex for XFP table
1.3.6.1.4.1.20044.86.7.1.2.1.2Columnrm10001wbRinvxfpLineread-onlycurrentInventory for the XFP: This OID contains the inventory for the XFP
1.3.6.1.4.1.20044.86.7.2Scalarrm10001wbRinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.86.7.3Scalarrm10001wbRinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.86.7.4Scalarrm10001wbRinvModulePlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.86.7.5Scalarrm10001wbRinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.86.7.6Scalarrm10001wbRinvGwPlatformread-onlycurrentGW platform description: This OID contains the description of the Gateware platform.
1.3.6.1.4.1.20044.86.8Noderm10001wbdownload
1.3.6.1.4.1.20044.86.8.1Noderm10001wbDwlOther
1.3.6.1.4.1.20044.86.8.1.0Noderm10001wbDwlrestartProcess
1.3.6.1.4.1.20044.86.8.1.0.1Scalarrm10001wbDwlWarmRestartProcessedread-onlycurrentWarm Restart :This OID indicates that the module last restart was a Warm RESTART
1.3.6.1.4.1.20044.86.8.1.0.2Scalarrm10001wbDwlColdRestartProcessedread-onlycurrentCold Restart :This OID indicates that the module last restart was a Cold RESTART
1.3.6.1.4.1.20044.86.8.1.1Noderm10001wbDwlswBanksUsed
1.3.6.1.4.1.20044.86.8.1.1.1Scalarrm10001wbDwlSwBank1Usedread-onlycurrentSW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby
1.3.6.1.4.1.20044.86.8.1.1.2Scalarrm10001wbDwlSwBank2Usedread-onlycurrentSW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby
1.3.6.1.4.1.20044.86.8.1.1.5Scalarrm10001wbDwlSwBank1Notemptyread-onlycurrentSW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package
1.3.6.1.4.1.20044.86.8.1.1.6Scalarrm10001wbDwlSwBank2Notemptyread-onlycurrentSW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package
1.3.6.1.4.1.20044.86.8.1.2Noderm10001wbDwlgwBanksUsed
1.3.6.1.4.1.20044.86.8.1.2.1Scalarrm10001wbDwlGwBank1Usedread-onlycurrentGW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby
1.3.6.1.4.1.20044.86.8.1.2.2Scalarrm10001wbDwlGwBank2Usedread-onlycurrentGW bank 2 active :This OID indicates the module is working on GW bank 2
1.3.6.1.4.1.20044.86.8.1.2.3Scalarrm10001wbDwlGwBank3Usedread-onlycurrentGW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby
1.3.6.1.4.1.20044.86.8.1.2.4Scalarrm10001wbDwlGwBank4Usedread-onlycurrentGW bank 4 active :This OID indicates the module is working on GW bank 4
1.3.6.1.4.1.20044.86.8.1.2.5Scalarrm10001wbDwlGwBank1Notemptyread-onlycurrentGW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package
1.3.6.1.4.1.20044.86.8.1.2.6Scalarrm10001wbDwlGwBank2Notemptyread-onlycurrentGW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2
1.3.6.1.4.1.20044.86.8.1.2.7Scalarrm10001wbDwlGwBank3Notemptyread-onlycurrentGW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package
1.3.6.1.4.1.20044.86.8.1.2.8Scalarrm10001wbDwlGwBank4Notemptyread-onlycurrentGW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4
1.3.6.1.4.1.20044.86.8.2Noderm10001wbDwlClient
1.3.6.1.4.1.20044.86.8.3Noderm10001wbDwlLine
1.3.6.1.4.1.20044.86.9Noderm10001wbConfig
1.3.6.1.4.1.20044.86.9.1Noderm10001wbCfgAccessCAisCsf
1.3.6.1.4.1.20044.86.9.1.1Tablerm10001wbCfgClientcaiscsfTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.86.9.1.1.1Rowrm10001wbCfgClientcaiscsfEntrynot-accessiblecurrentRow definition for the accessCAisCsf table
1.3.6.1.4.1.20044.86.9.1.1.1.1Columnrm10001wbCfgClientcaiscsfIndexread-onlycurrentIndex definition for the clientcaiscsf table
1.3.6.1.4.1.20044.86.9.1.1.1.3Columnrm10001wbCfgReservePortnread-writecurrentCAIS mode on Client Port :This register enables/disables port laser shutdown on CAIS insertion condition
1.3.6.1.4.1.20044.86.9.2Noderm10001wbCfgStartup
1.3.6.1.4.1.20044.86.9.2.1Tablerm10001wbCfgClientStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.86.9.2.1.1Rowrm10001wbCfgClientStartupEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.86.9.2.1.1.1Columnrm10001wbCfgClientStartupIndexread-onlycurrentIndex definition for the clientStartup table
1.3.6.1.4.1.20044.86.9.2.1.1.3Columnrm10001wbCfgSystConfPortPortnread-writecurrentDefault Settings on Client Port :This register configures the default initialisation settings on the port.
1.3.6.1.4.1.20044.86.9.2.1.1.4Columnrm10001wbCfgNetConfPortPortnread-writecurrentDefault Settings on Client Port :This register configures the default initialisation settings on the port.
1.3.6.1.4.1.20044.86.9.2.1.1.14Columnrm10001wbCfgOptionsPortPortnread-writecurrentDefault Options on Client Port :This register configures the default options on the port.
1.3.6.1.4.1.20044.86.9.2.2Tablerm10001wbCfgLineStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.86.9.2.2.1Rowrm10001wbCfgLineStartupEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.86.9.2.2.1.1Columnrm10001wbCfgLineStartupIndexread-onlycurrentIndex definition for the lineStartup table
1.3.6.1.4.1.20044.86.9.2.2.1.3Columnrm10001wbCfgSystConfLinePortnread-writecurrentDefault Settings on Line :This register configures the default initialisation settings on Line
1.3.6.1.4.1.20044.86.9.2.2.1.14Columnrm10001wbCfgOptionsLinePortnread-writecurrentDefault Options on Line :This register configures the default options on the line
1.3.6.1.4.1.20044.86.9.2.3Tablerm10001wbCfgXfpTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.86.9.2.3.1Rowrm10001wbCfgXfpEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.86.9.2.3.1.1Columnrm10001wbCfgXfpIndexread-onlycurrentIndex definition for the xfp table
1.3.6.1.4.1.20044.86.9.2.3.1.3Columnrm10001wbCfgSystConfMsaLinePortnread-writecurrentDefault settings on MSA :This register configures the default initialisation settings on MSA
1.3.6.1.4.1.20044.86.9.3Noderm10001wbCfgLabels
1.3.6.1.4.1.20044.86.9.3.1Tablerm10001wbCfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.86.9.3.1.1Rowrm10001wbCfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.86.9.3.1.1.1Columnrm10001wbCfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.86.9.3.1.1.3Columnrm10001wbCfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.86.9.3.2Tablerm10001wbCfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.86.9.3.2.1Rowrm10001wbCfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.86.9.3.2.1.1Columnrm10001wbCfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.86.9.3.2.1.3Columnrm10001wbCfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.86.9.4Noderm10001wbCfgStartuptlh
1.3.6.1.4.1.20044.86.9.4.1Tablerm10001wbCfgOtxtlhTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.86.9.4.1.1Rowrm10001wbCfgOtxtlhEntrynot-accessiblecurrentRow definition for the startuptlh table
1.3.6.1.4.1.20044.86.9.4.1.1.1Columnrm10001wbCfgOtxtlhIndexread-onlycurrentIndex definition for the otxtlh table
1.3.6.1.4.1.20044.86.9.4.1.1.6Columnrm10001wbCfgLinePwrLaserPortnread-writecurrentDefaut Line output Power :This register configures the start-up output power of the Line tranceiver (Unit = dBm)
1.3.6.1.4.1.20044.86.9.4.1.1.7Columnrm10001wbCfgLineFCurrentPortnread-writecurrentDefault Line transceiver Tx Channel :This register configures the start-up laser channel of the Line Tx transceiver
1.3.6.1.4.1.20044.86.9.4.1.1.8Columnrm10001wbCfgLineGridCurrentPortnread-writecurrentDefault Line transceiver Grid :This register configures the start-up laser grid of the Line transceiver
1.3.6.1.4.1.20044.86.9.4.1.1.9Columnrm10001wbCfgFPortnread-writecurrentDefault Line TRX lowest Freq :This register configures the start-up lowest frequency of the Line transceiver
1.3.6.1.4.1.20044.86.9.4.1.1.10Columnrm10001wbCfgRxLineFCurrentPortnread-writecurrentDefault Line transceiver Rx Channel :This register configures the start-up laser channel of the Line Rx transceiver
1.3.6.1.4.1.20044.86.9.5Noderm10001wbCfgOther
1.3.6.1.4.1.20044.86.9.5.1Noderm10001wbtablemoduleOther
1.3.6.1.4.1.20044.86.9.5.1.2Scalarrm10001wbCfgmoderead-writecurrentDefault settings on Module :This register selects the configuration mode of the module
1.3.6.1.4.1.20044.86.9.5.1.3Scalarrm10001wbCfgfanLowSpeedThresholdread-writecurrentDefault settings on Module :This register selects the speed threshold of the fan's
1.3.6.1.4.1.20044.86.9.5.1.4Scalarrm10001wbCfgfanHighSpeedThresholdread-writecurrentDefault settings on Module :This register selects the speed threshold of the fan's
1.3.6.1.4.1.20044.86.9.6Noderm10001wbCfgStartuptablefive
1.3.6.1.4.1.20044.86.9.6.1Tablerm10001wbCfgOtxtlhcapabilitiesTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.86.9.6.1.1Rowrm10001wbCfgOtxtlhcapabilitiesEntrynot-accessiblecurrentRow definition for the startuptablefive table
1.3.6.1.4.1.20044.86.9.6.1.1.1Columnrm10001wbCfgOtxtlhcapabilitiesIndexread-onlycurrentIndex definition for the otxtlhcapabilities table
1.3.6.1.4.1.20044.86.9.6.1.1.3Columnrm10001wbCfgComponentTypePortnread-onlycurrentComponent parameters :This OID defines the component parameters
1.3.6.1.4.1.20044.86.9.6.1.1.4Columnrm10001wbCfgMiscellaneousPortnread-onlycurrentMiscellaneous default settings :This OID defines the miscellaneous parameters
1.3.6.1.4.1.20044.86.9.6.1.1.5Columnrm10001wbCfgFirstChannelPortnread-onlycurrentNumber of the first channel of the component :This OID defines the first channel number of the PM
1.3.6.1.4.1.20044.86.9.6.1.1.6Columnrm10001wbCfgLastChannelPortnread-onlycurrentNumber of the last channel of the component :This OID defines the last channel number of the PM
1.3.6.1.4.1.20044.86.9.6.1.1.7Columnrm10001wbCfgGridPortnread-onlycurrentGrid value of the component :This OID defines the grid of the PM
1.3.6.1.4.1.20044.86.9.257Scalarrm10001wbCfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.86.10Noderm10001wbtraps
1.3.6.1.4.1.20044.86.10.2Scalarrm10001wbtrapPortNumberread-onlycurrentLast port which generates a trap
1.3.6.1.4.1.20044.86.10.3Scalarrm10001wbtrapLineNumberread-onlycurrentLast Line which generates a trap
1.3.6.1.4.1.20044.86.10.4Scalarrm10001wbtrapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.86.10.30Notificationrm10001wbLineTrapNotUrgentGoesOncurrentNot urgent Line default is activated
1.3.6.1.4.1.20044.86.10.31Notificationrm10001wbLineTrapNotUrgentGoesOffcurrentNot urgent Line default disappeared
1.3.6.1.4.1.20044.86.10.32Notificationrm10001wbLineTrapUrgentGoesOncurrentUrgent Line default is activated
1.3.6.1.4.1.20044.86.10.33Notificationrm10001wbLineTrapUrgentGoesOffcurrentUrgent Line default disappeared
1.3.6.1.4.1.20044.86.10.34Notificationrm10001wbLineTrapCritGoesOncurrentCritical Line default is activated
1.3.6.1.4.1.20044.86.10.35Notificationrm10001wbLineTrapCritGoesOffcurrentCritical Line default disappeared
1.3.6.1.4.1.20044.86.10.40Notificationrm10001wbClientTrapNotUrgentGoesOncurrentNot urgent client default is activated
1.3.6.1.4.1.20044.86.10.41Notificationrm10001wbClientTrapNotUrgentGoesOffcurrentNot urgent client default disappeared
1.3.6.1.4.1.20044.86.10.42Notificationrm10001wbClientTrapUrgentGoesOncurrentUrgent client default is activated
1.3.6.1.4.1.20044.86.10.43Notificationrm10001wbClientTrapUrgentGoesOffcurrentUrgent client default disappeared
1.3.6.1.4.1.20044.86.10.44Notificationrm10001wbClientTrapCritGoesOncurrentCritical client default is activated
1.3.6.1.4.1.20044.86.10.45Notificationrm10001wbClientTrapCritGoesOffcurrentCritical client default disappeared
1.3.6.1.4.1.20044.86.10.50Notificationrm10001wbPowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.86.10.51Notificationrm10001wbPowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared
1.3.6.1.4.1.20044.86.11Noderm10001wbMonitoring
1.3.6.1.4.1.20044.86.11.1Noderm10001wbMonOther
1.3.6.1.4.1.20044.86.11.1.3Noderm10001wbMonRmon
1.3.6.1.4.1.20044.86.11.2Noderm10001wbMonClient
1.3.6.1.4.1.20044.86.11.2.4Noderm10001wbMonClientRmonCounter
1.3.6.1.4.1.20044.86.11.2.4.16Tablerm10001wbMonupRmonBytesCounterClientInputTablenot-accessiblecurrentList of rm10001wbMonupRmonBytesCounterClientInput Article
1.3.6.1.4.1.20044.86.11.2.4.16.1Rowrm10001wbMonupRmonBytesCounterClientInputEntrynot-accessiblecurrentRow definition for the rm10001wbMonupRmonBytesCounterClientInput table
1.3.6.1.4.1.20044.86.11.2.4.16.1.1Columnrm10001wbMonupRmonBytesCounterClientInputIndexread-onlycurrentIndex definition for the rm10001wbMonupRmonBytesCounterClientInput table
1.3.6.1.4.1.20044.86.11.2.4.16.1.2Columnrm10001wbMonupRmonBytesCounterClientInputValuePortnread-onlycurrentClient Input Bytes :This counter is increased each time a data byte is received on the client port <Help> This counter gives the number of bytes received on th…
1.3.6.1.4.1.20044.86.11.2.4.16.1.3Columnrm10001wbMonupRmonBytesCounterClientInputErrorPortnread-onlycurrentBytes Counter Error :This OID when set indicates the Bytes counter value is invalid on client port
1.3.6.1.4.1.20044.86.11.2.4.16.1.4Columnrm10001wbMonupRmonBytesCounterClientInputOverloadPortnread-onlycurrentBytes Counter Overload :This OID when set indicates a Bytes counter overload on client port
1.3.6.1.4.1.20044.86.11.2.4.48Tablerm10001wbMonupRmonCrcErrorsCounterClientInputTablenot-accessiblecurrentList of rm10001wbMonupRmonCrcErrorsCounterClientInput Article
1.3.6.1.4.1.20044.86.11.2.4.48.1Rowrm10001wbMonupRmonCrcErrorsCounterClientInputEntrynot-accessiblecurrentRow definition for the rm10001wbMonupRmonCrcErrorsCounterClientInput table
1.3.6.1.4.1.20044.86.11.2.4.48.1.1Columnrm10001wbMonupRmonCrcErrorsCounterClientInputIndexread-onlycurrentIndex definition for the rm10001wbMonupRmonCrcErrorsCounterClientInput table
1.3.6.1.4.1.20044.86.11.2.4.48.1.2Columnrm10001wbMonupRmonCrcErrorsCounterClientInputValuePortnread-onlycurrentClient Input CRC Errors :This counter is increased each time a CRC error is detected on the client port<Help> This counter gives the number of CRC Errors recei…
1.3.6.1.4.1.20044.86.11.2.4.48.1.3Columnrm10001wbMonupRmonCrcErrorsCounterClientInputErrorPortnread-onlycurrentCRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on client port
1.3.6.1.4.1.20044.86.11.2.4.48.1.4Columnrm10001wbMonupRmonCrcErrorsCounterClientInputOverloadPortnread-onlycurrentCRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on client port
1.3.6.1.4.1.20044.86.11.2.4.80Tablerm10001wbMonupRmonPacketsCounterClientInputTablenot-accessiblecurrentList of rm10001wbMonupRmonPacketsCounterClientInput Article
1.3.6.1.4.1.20044.86.11.2.4.80.1Rowrm10001wbMonupRmonPacketsCounterClientInputEntrynot-accessiblecurrentRow definition for the rm10001wbMonupRmonPacketsCounterClientInput table
1.3.6.1.4.1.20044.86.11.2.4.80.1.1Columnrm10001wbMonupRmonPacketsCounterClientInputIndexread-onlycurrentIndex definition for the rm10001wbMonupRmonPacketsCounterClientInput table
1.3.6.1.4.1.20044.86.11.2.4.80.1.2Columnrm10001wbMonupRmonPacketsCounterClientInputValuePortnread-onlycurrentClient Input Packets :This counter is increased each time a packet is received on the client port <Help> This counter gives the number of packets received on t…
1.3.6.1.4.1.20044.86.11.2.4.80.1.3Columnrm10001wbMonupRmonPacketsCounterClientInputErrorPortnread-onlycurrentPackets Counter Error :This OID when set indicates the Packets counter value is invalid on client port
1.3.6.1.4.1.20044.86.11.2.4.80.1.4Columnrm10001wbMonupRmonPacketsCounterClientInputOverloadPortnread-onlycurrentPackets Counter Overload :This OID when set indicates a Packets counter overload on client port
1.3.6.1.4.1.20044.86.11.2.4.112Tablerm10001wbMonupRmonBroadcastCounterClientInputTablenot-accessiblecurrentList of rm10001wbMonupRmonBroadcastCounterClientInput Article
1.3.6.1.4.1.20044.86.11.2.4.112.1Rowrm10001wbMonupRmonBroadcastCounterClientInputEntrynot-accessiblecurrentRow definition for the rm10001wbMonupRmonBroadcastCounterClientInput table
1.3.6.1.4.1.20044.86.11.2.4.112.1.1Columnrm10001wbMonupRmonBroadcastCounterClientInputIndexread-onlycurrentIndex definition for the rm10001wbMonupRmonBroadcastCounterClientInput table
1.3.6.1.4.1.20044.86.11.2.4.112.1.2Columnrm10001wbMonupRmonBroadcastCounterClientInputValuePortnread-onlycurrentClient Input Broadcast Packets :This counter is increased each time a broadcast packet is received on the client port <Help> This counter gives the number of B…
1.3.6.1.4.1.20044.86.11.2.4.112.1.3Columnrm10001wbMonupRmonBroadcastCounterClientInputErrorPortnread-onlycurrentBroadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on client port
1.3.6.1.4.1.20044.86.11.2.4.112.1.4Columnrm10001wbMonupRmonBroadcastCounterClientInputOverloadPortnread-onlycurrentBroadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port
1.3.6.1.4.1.20044.86.11.2.4.144Tablerm10001wbMonupRmonMulticastCounterClientInputTablenot-accessiblecurrentList of rm10001wbMonupRmonMulticastCounterClientInput Article
1.3.6.1.4.1.20044.86.11.2.4.144.1Rowrm10001wbMonupRmonMulticastCounterClientInputEntrynot-accessiblecurrentRow definition for the rm10001wbMonupRmonMulticastCounterClientInput table
1.3.6.1.4.1.20044.86.11.2.4.144.1.1Columnrm10001wbMonupRmonMulticastCounterClientInputIndexread-onlycurrentIndex definition for the rm10001wbMonupRmonMulticastCounterClientInput table
1.3.6.1.4.1.20044.86.11.2.4.144.1.2Columnrm10001wbMonupRmonMulticastCounterClientInputValuePortnread-onlycurrentClient Input Multicast Packets :This counter is increased each time a Multicast packet is received on the client port <Help> This counter gives the number of M…
1.3.6.1.4.1.20044.86.11.2.4.144.1.3Columnrm10001wbMonupRmonMulticastCounterClientInputErrorPortnread-onlycurrentMulticast Counter Error :This OID when set indicates the Multicast counter value is invalid on client port
1.3.6.1.4.1.20044.86.11.2.4.144.1.4Columnrm10001wbMonupRmonMulticastCounterClientInputOverloadPortnread-onlycurrentMulticast Counter Overload :This OID when set indicates a Multicast counter overload on client port
1.3.6.1.4.1.20044.86.11.2.4.176Tablerm10001wbMonupRmonPauseFrameCounterClientInputTablenot-accessiblecurrentList of rm10001wbMonupRmonPauseFrameCounterClientInput Article
1.3.6.1.4.1.20044.86.11.2.4.176.1Rowrm10001wbMonupRmonPauseFrameCounterClientInputEntrynot-accessiblecurrentRow definition for the rm10001wbMonupRmonPauseFrameCounterClientInput table
1.3.6.1.4.1.20044.86.11.2.4.176.1.1Columnrm10001wbMonupRmonPauseFrameCounterClientInputIndexread-onlycurrentIndex definition for the rm10001wbMonupRmonPauseFrameCounterClientInput table
1.3.6.1.4.1.20044.86.11.2.4.176.1.2Columnrm10001wbMonupRmonPauseFrameCounterClientInputValuePortnread-onlycurrentClient Input Pause Frames :This counter is increased each time a Pause frame is received on the client port <Help> This counter gives the number of Pause frame…
1.3.6.1.4.1.20044.86.11.2.4.176.1.3Columnrm10001wbMonupRmonPauseFrameCounterClientInputErrorPortnread-onlycurrentPause Counter Error :This OID when set indicates the Pause counter value is invalid on client port
1.3.6.1.4.1.20044.86.11.2.4.176.1.4Columnrm10001wbMonupRmonPauseFrameCounterClientInputOverloadPortnread-onlycurrentPause Counter Overload :This OID when set indicates a Pause counter overload on client port
1.3.6.1.4.1.20044.86.11.2.4.304Tablerm10001wbMonupRmonUnicastCounterClientInputTablenot-accessiblecurrentList of rm10001wbMonupRmonUnicastCounterClientInput Article
1.3.6.1.4.1.20044.86.11.2.4.304.1Rowrm10001wbMonupRmonUnicastCounterClientInputEntrynot-accessiblecurrentRow definition for the rm10001wbMonupRmonUnicastCounterClientInput table
1.3.6.1.4.1.20044.86.11.2.4.304.1.1Columnrm10001wbMonupRmonUnicastCounterClientInputIndexread-onlycurrentIndex definition for the rm10001wbMonupRmonUnicastCounterClientInput table
1.3.6.1.4.1.20044.86.11.2.4.304.1.2Columnrm10001wbMonupRmonUnicastCounterClientInputValuePortnread-onlycurrentClient Input Unicast Packets :This counter is increased each time a Unicast packet is received on the client port <Help> This counter gives the number of Unica…
1.3.6.1.4.1.20044.86.11.2.4.304.1.3Columnrm10001wbMonupRmonUnicastCounterClientInputErrorPortnread-onlycurrentUnicast Counter Error :This OID when set indicates the Unicast counter value is invalid on client port
1.3.6.1.4.1.20044.86.11.2.4.304.1.4Columnrm10001wbMonupRmonUnicastCounterClientInputOverloadPortnread-onlycurrentUnicast Counter Overload :This OID when set indicates a Unicast counter overload on client port
1.3.6.1.4.1.20044.86.11.2.4.336Tablerm10001wbMonupRmonNonunicastCounterClientInputTablenot-accessiblecurrentList of rm10001wbMonupRmonNonunicastCounterClientInput Article
1.3.6.1.4.1.20044.86.11.2.4.336.1Rowrm10001wbMonupRmonNonunicastCounterClientInputEntrynot-accessiblecurrentRow definition for the rm10001wbMonupRmonNonunicastCounterClientInput table
1.3.6.1.4.1.20044.86.11.2.4.336.1.1Columnrm10001wbMonupRmonNonunicastCounterClientInputIndexread-onlycurrentIndex definition for the rm10001wbMonupRmonNonunicastCounterClientInput table
1.3.6.1.4.1.20044.86.11.2.4.336.1.2Columnrm10001wbMonupRmonNonunicastCounterClientInputValuePortnread-onlycurrentClient Input Non Unicast Packets :This counter is increased each time a Non-Unicast packet is received on the client port <Help> This counter gives the number …
1.3.6.1.4.1.20044.86.11.2.4.336.1.3Columnrm10001wbMonupRmonNonunicastCounterClientInputErrorPortnread-onlycurrentNon Unicast Counter Error :This OID when set indicates the Non-Unicast counter value is invalid on client port
1.3.6.1.4.1.20044.86.11.2.4.336.1.4Columnrm10001wbMonupRmonNonunicastCounterClientInputOverloadPortnread-onlycurrentNon Unicast Counter Overload :This OID when set indicates a Non-Unicast counter overload on client port
1.3.6.1.4.1.20044.86.11.2.4.400Tablerm10001wbMondownRmonBytesCounterClientOutputTablenot-accessiblecurrentList of rm10001wbMondownRmonBytesCounterClientOutput Article
1.3.6.1.4.1.20044.86.11.2.4.400.1Rowrm10001wbMondownRmonBytesCounterClientOutputEntrynot-accessiblecurrentRow definition for the rm10001wbMondownRmonBytesCounterClientOutput table
1.3.6.1.4.1.20044.86.11.2.4.400.1.1Columnrm10001wbMondownRmonBytesCounterClientOutputIndexread-onlycurrentIndex definition for the rm10001wbMondownRmonBytesCounterClientOutput table
1.3.6.1.4.1.20044.86.11.2.4.400.1.2Columnrm10001wbMondownRmonBytesCounterClientOutputValuePortnread-onlycurrentClient Output Bytes :This counter is increased each time a data byte is transmitted on the client port <Help> This counter gives the number of bytes transmitte…
1.3.6.1.4.1.20044.86.11.2.4.400.1.3Columnrm10001wbMondownRmonBytesCounterClientOutputErrorPortnread-onlycurrentBytes Counter Error :This OID when set indicates the Bytes counter value is invalid on client port
1.3.6.1.4.1.20044.86.11.2.4.400.1.4Columnrm10001wbMondownRmonBytesCounterClientOutputOverloadPortnread-onlycurrentBytes Counter Overload :This OID when set indicates a Bytes counter overload on client port
1.3.6.1.4.1.20044.86.11.2.4.432Tablerm10001wbMondownRmonCrcErrorsCounterClientOutputTablenot-accessiblecurrentList of rm10001wbMondownRmonCrcErrorsCounterClientOutput Article
1.3.6.1.4.1.20044.86.11.2.4.432.1Rowrm10001wbMondownRmonCrcErrorsCounterClientOutputEntrynot-accessiblecurrentRow definition for the rm10001wbMondownRmonCrcErrorsCounterClientOutput table
1.3.6.1.4.1.20044.86.11.2.4.432.1.1Columnrm10001wbMondownRmonCrcErrorsCounterClientOutputIndexread-onlycurrentIndex definition for the rm10001wbMondownRmonCrcErrorsCounterClientOutput table
1.3.6.1.4.1.20044.86.11.2.4.432.1.2Columnrm10001wbMondownRmonCrcErrorsCounterClientOutputValuePortnread-onlycurrentClient Output CRC Errors :This counter is increased each time a CRC error is detected on the transmit client port <Help> This counter gives the number of CRC E…
1.3.6.1.4.1.20044.86.11.2.4.432.1.3Columnrm10001wbMondownRmonCrcErrorsCounterClientOutputErrorPortnread-onlycurrentCRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on client port
1.3.6.1.4.1.20044.86.11.2.4.432.1.4Columnrm10001wbMondownRmonCrcErrorsCounterClientOutputOverloadPortnread-onlycurrentCRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on client port
1.3.6.1.4.1.20044.86.11.2.4.464Tablerm10001wbMondownRmonPacketsCounterClientOutputTablenot-accessiblecurrentList of rm10001wbMondownRmonPacketsCounterClientOutput Article
1.3.6.1.4.1.20044.86.11.2.4.464.1Rowrm10001wbMondownRmonPacketsCounterClientOutputEntrynot-accessiblecurrentRow definition for the rm10001wbMondownRmonPacketsCounterClientOutput table
1.3.6.1.4.1.20044.86.11.2.4.464.1.1Columnrm10001wbMondownRmonPacketsCounterClientOutputIndexread-onlycurrentIndex definition for the rm10001wbMondownRmonPacketsCounterClientOutput table
1.3.6.1.4.1.20044.86.11.2.4.464.1.2Columnrm10001wbMondownRmonPacketsCounterClientOutputValuePortnread-onlycurrentClient Output Packets :This counter is increased each time a packet is transmitted on the client port <Help> This counter gives the number of packets transmitt…
1.3.6.1.4.1.20044.86.11.2.4.464.1.3Columnrm10001wbMondownRmonPacketsCounterClientOutputErrorPortnread-onlycurrentPackets Counter Error :This OID when set indicates the Packets counter value is invalid on client port
1.3.6.1.4.1.20044.86.11.2.4.464.1.4Columnrm10001wbMondownRmonPacketsCounterClientOutputOverloadPortnread-onlycurrentPackets Counter Overload :This OID when set indicates a Packets counter overload on client port
1.3.6.1.4.1.20044.86.11.2.4.496Tablerm10001wbMondownRmonBroadcastCounterClientOutputTablenot-accessiblecurrentList of rm10001wbMondownRmonBroadcastCounterClientOutput Article
1.3.6.1.4.1.20044.86.11.2.4.496.1Rowrm10001wbMondownRmonBroadcastCounterClientOutputEntrynot-accessiblecurrentRow definition for the rm10001wbMondownRmonBroadcastCounterClientOutput table
1.3.6.1.4.1.20044.86.11.2.4.496.1.1Columnrm10001wbMondownRmonBroadcastCounterClientOutputIndexread-onlycurrentIndex definition for the rm10001wbMondownRmonBroadcastCounterClientOutput table
1.3.6.1.4.1.20044.86.11.2.4.496.1.2Columnrm10001wbMondownRmonBroadcastCounterClientOutputValuePortnread-onlycurrentClient Output Broadcast Packets :This counter is increased each time a broadcast packet is transmitted on the client port <Help> This counter gives the number …
1.3.6.1.4.1.20044.86.11.2.4.496.1.3Columnrm10001wbMondownRmonBroadcastCounterClientOutputErrorPortnread-onlycurrentBroadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on client port
1.3.6.1.4.1.20044.86.11.2.4.496.1.4Columnrm10001wbMondownRmonBroadcastCounterClientOutputOverloadPortnread-onlycurrentBroadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port
1.3.6.1.4.1.20044.86.11.2.4.528Tablerm10001wbMondownRmonMulticastCounterClientOutputTablenot-accessiblecurrentList of rm10001wbMondownRmonMulticastCounterClientOutput Article
1.3.6.1.4.1.20044.86.11.2.4.528.1Rowrm10001wbMondownRmonMulticastCounterClientOutputEntrynot-accessiblecurrentRow definition for the rm10001wbMondownRmonMulticastCounterClientOutput table
1.3.6.1.4.1.20044.86.11.2.4.528.1.1Columnrm10001wbMondownRmonMulticastCounterClientOutputIndexread-onlycurrentIndex definition for the rm10001wbMondownRmonMulticastCounterClientOutput table
1.3.6.1.4.1.20044.86.11.2.4.528.1.2Columnrm10001wbMondownRmonMulticastCounterClientOutputValuePortnread-onlycurrentClient Output Multicast Packets :This counter is increased each time a Multicast packet is transmitted on the client port <Help> This counter gives the number …
1.3.6.1.4.1.20044.86.11.2.4.528.1.3Columnrm10001wbMondownRmonMulticastCounterClientOutputErrorPortnread-onlycurrentMulticast Counter Error :This OID when set indicates the Multicast counter value is invalid on client port
1.3.6.1.4.1.20044.86.11.2.4.528.1.4Columnrm10001wbMondownRmonMulticastCounterClientOutputOverloadPortnread-onlycurrentMulticast Counter Overload :This OID when set indicates a Multicast counter overload on client port
1.3.6.1.4.1.20044.86.11.2.4.560Tablerm10001wbMondownRmonPauseFrameCounterClientOutputTablenot-accessiblecurrentList of rm10001wbMondownRmonPauseFrameCounterClientOutput Article
1.3.6.1.4.1.20044.86.11.2.4.560.1Rowrm10001wbMondownRmonPauseFrameCounterClientOutputEntrynot-accessiblecurrentRow definition for the rm10001wbMondownRmonPauseFrameCounterClientOutput table
1.3.6.1.4.1.20044.86.11.2.4.560.1.1Columnrm10001wbMondownRmonPauseFrameCounterClientOutputIndexread-onlycurrentIndex definition for the rm10001wbMondownRmonPauseFrameCounterClientOutput table
1.3.6.1.4.1.20044.86.11.2.4.560.1.2Columnrm10001wbMondownRmonPauseFrameCounterClientOutputValuePortnread-onlycurrentClient Output Pause Frames :This counter is increased each time a Pause frame is transmitted on the client port <Help> This counter gives the number of Pause f…
1.3.6.1.4.1.20044.86.11.2.4.560.1.3Columnrm10001wbMondownRmonPauseFrameCounterClientOutputErrorPortnread-onlycurrentPause Counter Error :This OID when set indicates the Pause counter value is invalid on client port
1.3.6.1.4.1.20044.86.11.2.4.560.1.4Columnrm10001wbMondownRmonPauseFrameCounterClientOutputOverloadPortnread-onlycurrentPause Counter Overload :This OID when set indicates a Pause counter overload on client port
1.3.6.1.4.1.20044.86.11.2.4.688Tablerm10001wbMondownRmonUnicastCounterClientOutputTablenot-accessiblecurrentList of rm10001wbMondownRmonUnicastCounterClientOutput Article
1.3.6.1.4.1.20044.86.11.2.4.688.1Rowrm10001wbMondownRmonUnicastCounterClientOutputEntrynot-accessiblecurrentRow definition for the rm10001wbMondownRmonUnicastCounterClientOutput table
1.3.6.1.4.1.20044.86.11.2.4.688.1.1Columnrm10001wbMondownRmonUnicastCounterClientOutputIndexread-onlycurrentIndex definition for the rm10001wbMondownRmonUnicastCounterClientOutput table
1.3.6.1.4.1.20044.86.11.2.4.688.1.2Columnrm10001wbMondownRmonUnicastCounterClientOutputValuePortnread-onlycurrentClient Output Unicast Packets :This counter is increased each time a Unicast packet is transmitted on the client port <Help> This counter gives the number of U…
1.3.6.1.4.1.20044.86.11.2.4.688.1.3Columnrm10001wbMondownRmonUnicastCounterClientOutputErrorPortnread-onlycurrentUnicast Counter Error :This OID when set indicates the Unicast counter value is invalid on client port
1.3.6.1.4.1.20044.86.11.2.4.688.1.4Columnrm10001wbMondownRmonUnicastCounterClientOutputOverloadPortnread-onlycurrentUnicast Counter Overload :This OID when set indicates a Unicast counter overload on client port
1.3.6.1.4.1.20044.86.11.2.4.720Tablerm10001wbMondownRmonNonunicastCounterClientOutputTablenot-accessiblecurrentList of rm10001wbMondownRmonNonunicastCounterClientOutput Article
1.3.6.1.4.1.20044.86.11.2.4.720.1Rowrm10001wbMondownRmonNonunicastCounterClientOutputEntrynot-accessiblecurrentRow definition for the rm10001wbMondownRmonNonunicastCounterClientOutput table
1.3.6.1.4.1.20044.86.11.2.4.720.1.1Columnrm10001wbMondownRmonNonunicastCounterClientOutputIndexread-onlycurrentIndex definition for the rm10001wbMondownRmonNonunicastCounterClientOutput table
1.3.6.1.4.1.20044.86.11.2.4.720.1.2Columnrm10001wbMondownRmonNonunicastCounterClientOutputValuePortnread-onlycurrentClient Output Non Unicast Packets :This counter is increased each time a Non-Unicast packet is transmitted on the client port <Help> This counter gives the num…
1.3.6.1.4.1.20044.86.11.2.4.720.1.3Columnrm10001wbMondownRmonNonunicastCounterClientOutputErrorPortnread-onlycurrentNon Unicast Counter Error :This OID when set indicates the Non-Unicast counter value is invalid on client port
1.3.6.1.4.1.20044.86.11.2.4.720.1.4Columnrm10001wbMondownRmonNonunicastCounterClientOutputOverloadPortnread-onlycurrentNon Unicast Counter Overload :This OID when set indicates a Non-Unicast counter overload on client port
1.3.6.1.4.1.20044.86.11.5Noderm10001wbMonPerfOther
1.3.6.1.4.1.20044.86.11.5.1Noderm10001wbMonPerfSync
1.3.6.1.4.1.20044.86.11.5.1.257Scalarrm10001wbPerfEnableread-writecurrentPerf. Mon. Enable :This OID enables the Performance Monitoring application
1.3.6.1.4.1.20044.86.11.5.1.259Scalarrm10001wbPerf15minSyncread-writecurrentPerf. Mon. 15-min sync. :This OID must be used in external synchronisation mode only to send a 15-min synchronisation command
1.3.6.1.4.1.20044.86.11.5.1.260Scalarrm10001wbPerf24hSyncread-writecurrentPerf. Mon. 24-hours sync. :This OID must be used in external synchronisation mode only to send a 24-hours synchronisation command
1.3.6.1.4.1.20044.86.11.5.2Noderm10001wbMonPerfTimeStamp
1.3.6.1.4.1.20044.86.11.5.2.1Scalarrm10001wbPerf15MinShortread-writecurrent15-min period is short :This OID indicates that the 15-min period lasts less than 890 seconds
1.3.6.1.4.1.20044.86.11.5.2.2Scalarrm10001wbPerf15MinLongread-writecurrent15-min period is long :This OID indicates that the 15-min period lasts more than 910 seconds
1.3.6.1.4.1.20044.86.11.5.2.5Scalarrm10001wbPerf24HoursShortread-writecurrent24-hours period is short :This OID indicates that 24-hours period lasts less than 86390 seconds
1.3.6.1.4.1.20044.86.11.5.2.6Scalarrm10001wbPerf24HoursLongread-writecurrent24-hours period is long :This OID indicates that 24-hours period lasts more than 86410 seconds
1.3.6.1.4.1.20044.86.11.5.2.7Scalarrm10001wbPerfCurrent15MinElapsedTimeread-writecurrentCurrent 15min period Elapsed Time :This OID gives the number of seconds elapsed in the current 15-minutes period
1.3.6.1.4.1.20044.86.11.5.2.8Scalarrm10001wbPerfCurrent24HoursElapsedTimeread-writecurrentCurrent 24hours period Elapsed Time :This OID gives the number of seconds elapsed in the current 24-hours period
1.3.6.1.4.1.20044.86.11.6Noderm10001wbMonPerfClient
1.3.6.1.4.1.20044.86.11.6.16Tablerm10001wbPerfTelecomInputClientCurrent15StatTablenot-accessiblecurrentList of rm10001wbPerfTelecomInputClientCurrent15Stat Article
1.3.6.1.4.1.20044.86.11.6.16.1Rowrm10001wbPerfTelecomInputClientCurrent15StatEntrynot-accessiblecurrentRow definition for the rm10001wbPerfTelecomInputClientCurrent15Stat table
1.3.6.1.4.1.20044.86.11.6.16.1.1Columnrm10001wbPerfTelecomInputClientCurrent15StatIndexread-onlycurrentIndex definition for the rm10001wbPerfTelecomInputClientCurrent15Stat table
1.3.6.1.4.1.20044.86.11.6.16.1.2Columnrm10001wbPerfTelecomInputClientCurrent15StatInvCvPortnread-onlycurrentCurrent 15-min EBC counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.86.11.6.16.1.3Columnrm10001wbPerfTelecomInputClientCurrent15StatCvValuePortnread-onlycurrentCurrent 15-min EBC counter :This OID gives the current 15-min Coding Violation counter value
1.3.6.1.4.1.20044.86.11.6.16.1.4Columnrm10001wbPerfTelecomInputClientCurrent15StatInvEsPortnread-onlycurrentCurrent 15-min ES counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.16.1.5Columnrm10001wbPerfTelecomInputClientCurrent15StatEsValuePortnread-onlycurrentCurrent 15-min ES counter :This OID gives the current 15-min Errored Second counter value
1.3.6.1.4.1.20044.86.11.6.16.1.6Columnrm10001wbPerfTelecomInputClientCurrent15StatInvSesPortnread-onlycurrentCurrent 15-min SES counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.16.1.7Columnrm10001wbPerfTelecomInputClientCurrent15StatSesValuePortnread-onlycurrentCurrent 15-min SES counter :This OID gives the current 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.86.11.6.16.1.8Columnrm10001wbPerfTelecomInputClientCurrent15StatInvSefsPortnread-onlycurrentCurrent 15-min SEFS counter inv. :This OID indicates that the current 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.16.1.9Columnrm10001wbPerfTelecomInputClientCurrent15StatSefsValuePortnread-onlycurrentCurrent 15-min SEFS counter :This OID gives the current 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.86.11.6.16.1.10Columnrm10001wbPerfTelecomInputClientCurrent15StatInvUasPortnread-onlycurrentCurrent 15-min UAS counter inv. :This OID indicates that the current 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.16.1.11Columnrm10001wbPerfTelecomInputClientCurrent15StatUasValuePortnread-onlycurrentCurrent 15-min UAS counter :This OID gives the current 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.86.11.6.48Tablerm10001wbPerfTelecomInputClientPast15StatHistoryPort1Tablenot-accessiblecurrentList of rm10001wbPerfTelecomInputClientPast15StatHistory Article
1.3.6.1.4.1.20044.86.11.6.48.1Rowrm10001wbPerfTelecomInputClientPast15StatHistoryPort1Entrynot-accessiblecurrentRow definition for the rm10001wbPerfTelecomInputClientPast15StatHistory table
1.3.6.1.4.1.20044.86.11.6.48.1.1Columnrm10001wbPerfTelecomInputClientPast15StatHistoryPort1Indexread-onlycurrentIndex definition for the rm10001wbPerfTelecomInputClientPast15StatHistory table
1.3.6.1.4.1.20044.86.11.6.48.1.2Columnrm10001wbPerfTelecomInputClientPast15StatHistoryInvCvPort1read-onlycurrentPrevious 15-min EBC counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.86.11.6.48.1.3Columnrm10001wbPerfTelecomInputClientPast15StatHistoryCvValuePort1read-onlycurrentPrevious 15-min EBC counter :This OID gives the previous 15-min Coding Violation counter value
1.3.6.1.4.1.20044.86.11.6.48.1.4Columnrm10001wbPerfTelecomInputClientPast15StatHistoryInvEsPort1read-onlycurrentPrevious 15-min ES counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.48.1.5Columnrm10001wbPerfTelecomInputClientPast15StatHistoryEsValuePort1read-onlycurrentPrevious 15-min ES counter :This OID gives the previous 15-min Errored Second counter value
1.3.6.1.4.1.20044.86.11.6.48.1.6Columnrm10001wbPerfTelecomInputClientPast15StatHistoryInvSesPort1read-onlycurrentPrevious 15-min SES counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.48.1.7Columnrm10001wbPerfTelecomInputClientPast15StatHistorySesValuePort1read-onlycurrentPrevious 15-min SES counter :This OID gives the previous 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.86.11.6.48.1.8Columnrm10001wbPerfTelecomInputClientPast15StatHistoryInvSefsPort1read-onlycurrentPrevious 15-min SEFS counter inv. :This OID indicates that the previous 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.48.1.9Columnrm10001wbPerfTelecomInputClientPast15StatHistorySefsValuePort1read-onlycurrentPrevious 15-min SEFS counter :This OID gives the previous 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.86.11.6.48.1.10Columnrm10001wbPerfTelecomInputClientPast15StatHistoryInvUasPort1read-onlycurrentPrevious 15-min UAS counter inv. :This OID indicates that the previous 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.48.1.11Columnrm10001wbPerfTelecomInputClientPast15StatHistoryUasValuePort1read-onlycurrentPrevious 15-min UAS counter :This OID gives the previous 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.86.11.6.80Tablerm10001wbPerfTelecomInputClientCurrent24StatTablenot-accessiblecurrentList of rm10001wbPerfTelecomInputClientCurrent24Stat Article
1.3.6.1.4.1.20044.86.11.6.80.1Rowrm10001wbPerfTelecomInputClientCurrent24StatEntrynot-accessiblecurrentRow definition for the rm10001wbPerfTelecomInputClientCurrent24Stat table
1.3.6.1.4.1.20044.86.11.6.80.1.1Columnrm10001wbPerfTelecomInputClientCurrent24StatIndexread-onlycurrentIndex definition for the rm10001wbPerfTelecomInputClientCurrent24Stat table
1.3.6.1.4.1.20044.86.11.6.80.1.2Columnrm10001wbPerfTelecomInputClientCurrent24StatInvCvPortnread-onlycurrentCurrent 24-hours EBC counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.86.11.6.80.1.3Columnrm10001wbPerfTelecomInputClientCurrent24StatCvValuePortnread-onlycurrentCurrent 24-hours EBC counter :This OID gives the current 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.86.11.6.80.1.4Columnrm10001wbPerfTelecomInputClientCurrent24StatInvEsPortnread-onlycurrentCurrent 24-hours ES counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.80.1.5Columnrm10001wbPerfTelecomInputClientCurrent24StatEsValuePortnread-onlycurrentCurrent 24-hours ES counter :This OID gives the current 24-hours Errored Second counter value
1.3.6.1.4.1.20044.86.11.6.80.1.6Columnrm10001wbPerfTelecomInputClientCurrent24StatInvSesPortnread-onlycurrentCurrent 24-hours SES counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.80.1.7Columnrm10001wbPerfTelecomInputClientCurrent24StatSesValuePortnread-onlycurrentCurrent 24-hours SES counter :This OID gives the current 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.86.11.6.80.1.8Columnrm10001wbPerfTelecomInputClientCurrent24StatInvSefsPortnread-onlycurrentCurrent 24-hours SEFS counter inv. :This OID indicates that the current 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.80.1.9Columnrm10001wbPerfTelecomInputClientCurrent24StatSefsValuePortnread-onlycurrentCurrent 24-hours SEFS counter :This OID gives the current 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.86.11.6.80.1.10Columnrm10001wbPerfTelecomInputClientCurrent24StatInvUasPortnread-onlycurrentCurrent 24-hours UAS counter inv. :This OID indicates that the current 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.80.1.11Columnrm10001wbPerfTelecomInputClientCurrent24StatUasValuePortnread-onlycurrentCurrent 24-hours UAS counter :This OID gives the current 24-hours UnAvailable Second counter value
1.3.6.1.4.1.20044.86.11.6.112Tablerm10001wbPerfTelecomInputClientPast24StatHistoryPort1Tablenot-accessiblecurrentList of rm10001wbPerfTelecomInputClientPast24StatHistory Article
1.3.6.1.4.1.20044.86.11.6.112.1Rowrm10001wbPerfTelecomInputClientPast24StatHistoryPort1Entrynot-accessiblecurrentRow definition for the rm10001wbPerfTelecomInputClientPast24StatHistory table
1.3.6.1.4.1.20044.86.11.6.112.1.1Columnrm10001wbPerfTelecomInputClientPast24StatHistoryPort1Indexread-onlycurrentIndex definition for the rm10001wbPerfTelecomInputClientPast24StatHistory table
1.3.6.1.4.1.20044.86.11.6.112.1.2Columnrm10001wbPerfTelecomInputClientPast24StatHistoryInvCvPort1read-onlycurrentPrevious 24-hours EBC counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.86.11.6.112.1.3Columnrm10001wbPerfTelecomInputClientPast24StatHistoryCvValuePort1read-onlycurrentPrevious 24-hours EBC counter :This OID gives the previous 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.86.11.6.112.1.4Columnrm10001wbPerfTelecomInputClientPast24StatHistoryInvEsPort1read-onlycurrentPrevious 24-hours ES counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.112.1.5Columnrm10001wbPerfTelecomInputClientPast24StatHistoryEsValuePort1read-onlycurrentPrevious 24-hours ES counter :This OID gives the previous 24-hours Errored Second counter value
1.3.6.1.4.1.20044.86.11.6.112.1.6Columnrm10001wbPerfTelecomInputClientPast24StatHistoryInvSesPort1read-onlycurrentPrevious 24-hours SES counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.112.1.7Columnrm10001wbPerfTelecomInputClientPast24StatHistorySesValuePort1read-onlycurrentPrevious 24-hours SES counter :This OID gives the previous 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.86.11.6.112.1.8Columnrm10001wbPerfTelecomInputClientPast24StatHistoryInvSefsPort1read-onlycurrentPrevious 24-hours SEFS counter inv. :This OID indicates that the previous 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.112.1.9Columnrm10001wbPerfTelecomInputClientPast24StatHistorySefsValuePort1read-onlycurrentPrevious 24-hours SEFS counter :This OID gives the previous 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.86.11.6.112.1.10Columnrm10001wbPerfTelecomInputClientPast24StatHistoryInvUasPort1read-onlycurrentPrevious 24-hours UAS counter inv. :This OID indicates that the previous 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.112.1.11Columnrm10001wbPerfTelecomInputClientPast24StatHistoryUasValuePort1read-onlycurrentPrevious 24-hours UAS counter :This OID gives the previous 24-hours UnAvailable Second counter value
1.3.6.1.4.1.20044.86.11.6.144Tablerm10001wbPerfTelecomOutputClientCurrent15StatTablenot-accessiblecurrentList of rm10001wbPerfTelecomOutputClientCurrent15Stat Article
1.3.6.1.4.1.20044.86.11.6.144.1Rowrm10001wbPerfTelecomOutputClientCurrent15StatEntrynot-accessiblecurrentRow definition for the rm10001wbPerfTelecomOutputClientCurrent15Stat table
1.3.6.1.4.1.20044.86.11.6.144.1.1Columnrm10001wbPerfTelecomOutputClientCurrent15StatIndexread-onlycurrentIndex definition for the rm10001wbPerfTelecomOutputClientCurrent15Stat table
1.3.6.1.4.1.20044.86.11.6.144.1.2Columnrm10001wbPerfTelecomOutputClientCurrent15StatInvCvPortnread-onlycurrentCurrent 15-min EBC counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.86.11.6.144.1.3Columnrm10001wbPerfTelecomOutputClientCurrent15StatCvValuePortnread-onlycurrentCurrent 15-min EBC counter :This OID gives the current 15-min Coding Violation counter value
1.3.6.1.4.1.20044.86.11.6.144.1.4Columnrm10001wbPerfTelecomOutputClientCurrent15StatInvEsPortnread-onlycurrentCurrent 15-min ES counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.144.1.5Columnrm10001wbPerfTelecomOutputClientCurrent15StatEsValuePortnread-onlycurrentCurrent 15-min ES counter :This OID gives the current 15-min Errored Second counter value
1.3.6.1.4.1.20044.86.11.6.144.1.6Columnrm10001wbPerfTelecomOutputClientCurrent15StatInvSesPortnread-onlycurrentCurrent 15-min SES counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.144.1.7Columnrm10001wbPerfTelecomOutputClientCurrent15StatSesValuePortnread-onlycurrentCurrent 15-min SES counter :This OID gives the current 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.86.11.6.144.1.8Columnrm10001wbPerfTelecomOutputClientCurrent15StatInvSefsPortnread-onlycurrentCurrent 15-min SEFS counter inv. :This OID indicates that the current 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.144.1.9Columnrm10001wbPerfTelecomOutputClientCurrent15StatSefsValuePortnread-onlycurrentCurrent 15-min SEFS counter :This OID gives the current 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.86.11.6.144.1.10Columnrm10001wbPerfTelecomOutputClientCurrent15StatInvUasPortnread-onlycurrentCurrent 15-min UAS counter inv. :This OID indicates that the current 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.144.1.11Columnrm10001wbPerfTelecomOutputClientCurrent15StatUasValuePortnread-onlycurrentCurrent 15-min UAS counter :This OID gives the current 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.86.11.6.176Tablerm10001wbPerfTelecomOutputClientPast15StatHistoryPort1Tablenot-accessiblecurrentList of rm10001wbPerfTelecomOutputClientPast15StatHistory Article
1.3.6.1.4.1.20044.86.11.6.176.1Rowrm10001wbPerfTelecomOutputClientPast15StatHistoryPort1Entrynot-accessiblecurrentRow definition for the rm10001wbPerfTelecomOutputClientPast15StatHistory table
1.3.6.1.4.1.20044.86.11.6.176.1.1Columnrm10001wbPerfTelecomOutputClientPast15StatHistoryPort1Indexread-onlycurrentIndex definition for the rm10001wbPerfTelecomOutputClientPast15StatHistory table
1.3.6.1.4.1.20044.86.11.6.176.1.2Columnrm10001wbPerfTelecomOutputClientPast15StatHistoryInvCvPort1read-onlycurrentPrevious 15-min EBC counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.86.11.6.176.1.3Columnrm10001wbPerfTelecomOutputClientPast15StatHistoryCvValuePort1read-onlycurrentPrevious 15-min EBC counter :This OID gives the previous 15-min Coding Violation counter value
1.3.6.1.4.1.20044.86.11.6.176.1.4Columnrm10001wbPerfTelecomOutputClientPast15StatHistoryInvEsPort1read-onlycurrentPrevious 15-min ES counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.176.1.5Columnrm10001wbPerfTelecomOutputClientPast15StatHistoryEsValuePort1read-onlycurrentPrevious 15-min ES counter :This OID gives the previous 15-min Errored Second counter value
1.3.6.1.4.1.20044.86.11.6.176.1.6Columnrm10001wbPerfTelecomOutputClientPast15StatHistoryInvSesPort1read-onlycurrentPrevious 15-min SES counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.176.1.7Columnrm10001wbPerfTelecomOutputClientPast15StatHistorySesValuePort1read-onlycurrentPrevious 15-min SES counter :This OID gives the previous 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.86.11.6.176.1.8Columnrm10001wbPerfTelecomOutputClientPast15StatHistoryInvSefsPort1read-onlycurrentPrevious 15-min SEFS counter inv. :This OID indicates that the previous 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.176.1.9Columnrm10001wbPerfTelecomOutputClientPast15StatHistorySefsValuePort1read-onlycurrentPrevious 15-min SEFS counter :This OID gives the previous 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.86.11.6.176.1.10Columnrm10001wbPerfTelecomOutputClientPast15StatHistoryInvUasPort1read-onlycurrentPrevious 15-min UAS counter inv. :This OID indicates that the previous 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.176.1.11Columnrm10001wbPerfTelecomOutputClientPast15StatHistoryUasValuePort1read-onlycurrentPrevious 15-min UAS counter :This OID gives the previous 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.86.11.6.208Tablerm10001wbPerfTelecomOutputClientCurrent24StatTablenot-accessiblecurrentList of rm10001wbPerfTelecomOutputClientCurrent24Stat Article
1.3.6.1.4.1.20044.86.11.6.208.1Rowrm10001wbPerfTelecomOutputClientCurrent24StatEntrynot-accessiblecurrentRow definition for the rm10001wbPerfTelecomOutputClientCurrent24Stat table
1.3.6.1.4.1.20044.86.11.6.208.1.1Columnrm10001wbPerfTelecomOutputClientCurrent24StatIndexread-onlycurrentIndex definition for the rm10001wbPerfTelecomOutputClientCurrent24Stat table
1.3.6.1.4.1.20044.86.11.6.208.1.2Columnrm10001wbPerfTelecomOutputClientCurrent24StatInvCvPortnread-onlycurrentCurrent 24-hours EBC counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.86.11.6.208.1.3Columnrm10001wbPerfTelecomOutputClientCurrent24StatCvValuePortnread-onlycurrentCurrent 24-hours EBC counter :This OID gives the current 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.86.11.6.208.1.4Columnrm10001wbPerfTelecomOutputClientCurrent24StatInvEsPortnread-onlycurrentCurrent 24-hours ES counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.208.1.5Columnrm10001wbPerfTelecomOutputClientCurrent24StatEsValuePortnread-onlycurrentCurrent 24-hours ES counter :This OID gives the current 24-hours Errored Second counter value
1.3.6.1.4.1.20044.86.11.6.208.1.6Columnrm10001wbPerfTelecomOutputClientCurrent24StatInvSesPortnread-onlycurrentCurrent 24-hours SES counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.208.1.7Columnrm10001wbPerfTelecomOutputClientCurrent24StatSesValuePortnread-onlycurrentCurrent 24-hours SES counter :This OID gives the current 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.86.11.6.208.1.8Columnrm10001wbPerfTelecomOutputClientCurrent24StatInvSefsPortnread-onlycurrentCurrent 24-hours SEFS counter inv. :This OID indicates that the current 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.208.1.9Columnrm10001wbPerfTelecomOutputClientCurrent24StatSefsValuePortnread-onlycurrentCurrent 24-hours SEFS counter :This OID gives the current 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.86.11.6.208.1.10Columnrm10001wbPerfTelecomOutputClientCurrent24StatInvUasPortnread-onlycurrentCurrent 24-hours UAS counter inv. :This OID indicates that the current 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.208.1.11Columnrm10001wbPerfTelecomOutputClientCurrent24StatUasValuePortnread-onlycurrentCurrent 24-hours UAS counter :This OID gives the current 24-hours UnAvailable Second counter value
1.3.6.1.4.1.20044.86.11.6.240Tablerm10001wbPerfTelecomOutputClientPast24StatHistoryPort1Tablenot-accessiblecurrentList of rm10001wbPerfTelecomOutputClientPast24StatHistory Article
1.3.6.1.4.1.20044.86.11.6.240.1Rowrm10001wbPerfTelecomOutputClientPast24StatHistoryPort1Entrynot-accessiblecurrentRow definition for the rm10001wbPerfTelecomOutputClientPast24StatHistory table
1.3.6.1.4.1.20044.86.11.6.240.1.1Columnrm10001wbPerfTelecomOutputClientPast24StatHistoryPort1Indexread-onlycurrentIndex definition for the rm10001wbPerfTelecomOutputClientPast24StatHistory table
1.3.6.1.4.1.20044.86.11.6.240.1.2Columnrm10001wbPerfTelecomOutputClientPast24StatHistoryInvCvPort1read-onlycurrentPrevious 24-hours EBC counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.86.11.6.240.1.3Columnrm10001wbPerfTelecomOutputClientPast24StatHistoryCvValuePort1read-onlycurrentPrevious 24-hours EBC counter :This OID gives the previous 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.86.11.6.240.1.4Columnrm10001wbPerfTelecomOutputClientPast24StatHistoryInvEsPort1read-onlycurrentPrevious 24-hours ES counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.240.1.5Columnrm10001wbPerfTelecomOutputClientPast24StatHistoryEsValuePort1read-onlycurrentPrevious 24-hours ES counter :This OID gives the previous 24-hours Errored Second counter value
1.3.6.1.4.1.20044.86.11.6.240.1.6Columnrm10001wbPerfTelecomOutputClientPast24StatHistoryInvSesPort1read-onlycurrentPrevious 24-hours SES counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.240.1.7Columnrm10001wbPerfTelecomOutputClientPast24StatHistorySesValuePort1read-onlycurrentPrevious 24-hours SES counter :This OID gives the previous 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.86.11.6.240.1.8Columnrm10001wbPerfTelecomOutputClientPast24StatHistoryInvSefsPort1read-onlycurrentPrevious 24-hours SEFS counter inv. :This OID indicates that the previous 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.240.1.9Columnrm10001wbPerfTelecomOutputClientPast24StatHistorySefsValuePort1read-onlycurrentPrevious 24-hours SEFS counter :This OID gives the previous 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.86.11.6.240.1.10Columnrm10001wbPerfTelecomOutputClientPast24StatHistoryInvUasPort1read-onlycurrentPrevious 24-hours UAS counter inv. :This OID indicates that the previous 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.86.11.6.240.1.11Columnrm10001wbPerfTelecomOutputClientPast24StatHistoryUasValuePort1read-onlycurrentPrevious 24-hours UAS counter :This OID gives the previous 24-hours UnAvailable Second counter value
1.3.6.1.4.1.20044.86.11.6.848Tablerm10001wbPerfDatacomClientCurrent15StatTablenot-accessiblecurrentList of rm10001wbPerfDatacomClientCurrent15Stat Article
1.3.6.1.4.1.20044.86.11.6.848.1Rowrm10001wbPerfDatacomClientCurrent15StatEntrynot-accessiblecurrentRow definition for the rm10001wbPerfDatacomClientCurrent15Stat table
1.3.6.1.4.1.20044.86.11.6.848.1.1Columnrm10001wbPerfDatacomClientCurrent15StatIndexread-onlycurrentIndex definition for the rm10001wbPerfDatacomClientCurrent15Stat table
1.3.6.1.4.1.20044.86.11.6.848.1.4Columnrm10001wbperfdatacomclientCurrent15StatInCrcCountInvPortnread-onlycurrentClient Current 15-min Input CRC counter inv. :This OID indicates that the current 15-min Input CRC counter is invalid
1.3.6.1.4.1.20044.86.11.6.848.1.5Columnrm10001wbperfdatacomclientCurrent15StatInCrcCountPortnread-onlycurrentClient Current 15-min Input CRC counter :This OID gives the current 15-min Input CRC counter value
1.3.6.1.4.1.20044.86.11.6.848.1.6Columnrm10001wbperfdatacomclientCurrent15StatInPacketCountInvPortnread-onlycurrentClient Current 15-min Input Packet counter inv. :This OID indicates that the current 15-min Input Packet counter is invalid
1.3.6.1.4.1.20044.86.11.6.848.1.7Columnrm10001wbperfdatacomclientCurrent15StatInPacketCountPortnread-onlycurrentClient Current 15-min Input Packet counter :This OID gives the current 15-min Input Packet counter value
1.3.6.1.4.1.20044.86.11.6.848.1.28Columnrm10001wbperfdatacomclientCurrent15StatOutCrcCountInvPortnread-onlycurrentClient Current 15-min Output CRC counter inv. :This OID indicates that the current 15-min Output CRC counter is invalid
1.3.6.1.4.1.20044.86.11.6.848.1.29Columnrm10001wbperfdatacomclientCurrent15StatOutCrcCountPortnread-onlycurrentClient Current 15-min Output CRC counter :This OID gives the current 15-min Output CRC counter value
1.3.6.1.4.1.20044.86.11.6.848.1.30Columnrm10001wbperfdatacomclientCurrent15StatOutPacketCountInvPortnread-onlycurrentClient Current 15-min Output Packet counter inv. :This OID indicates that the current 15-min Output Packets counter is invalid
1.3.6.1.4.1.20044.86.11.6.848.1.31Columnrm10001wbperfdatacomclientCurrent15StatOutPacketCountPortnread-onlycurrentClient Current 15-min Output Packet counter :This OID gives the current 15-min Output Packets counter value
1.3.6.1.4.1.20044.86.11.6.880Tablerm10001wbPerfDatacomClientPast15StatHistoryPort1Tablenot-accessiblecurrentList of rm10001wbPerfDatacomClientPast15StatHistory Article
1.3.6.1.4.1.20044.86.11.6.880.1Rowrm10001wbPerfDatacomClientPast15StatHistoryPort1Entrynot-accessiblecurrentRow definition for the rm10001wbPerfDatacomClientPast15StatHistory table
1.3.6.1.4.1.20044.86.11.6.880.1.1Columnrm10001wbPerfDatacomClientPast15StatHistoryPort1Indexread-onlycurrentIndex definition for the rm10001wbPerfDatacomClientPast15StatHistory table
1.3.6.1.4.1.20044.86.11.6.880.1.4Columnrm10001wbperfdatacomclientPast15StatInCrcCountInvPort1read-onlycurrentClient Past 15-min Input CRC counter inv. :This OID indicates that the past 15-min Input CRC counter is invalid
1.3.6.1.4.1.20044.86.11.6.880.1.5Columnrm10001wbperfdatacomclientPast15StatInCrcCountPort1read-onlycurrentClient Past 15-min Input CRC counter :This OID gives the past 15-min Input CRC counter value
1.3.6.1.4.1.20044.86.11.6.880.1.6Columnrm10001wbperfdatacomclientPast15StatInPacketCountInvPort1read-onlycurrentClient Past 15-min Input Packet counter inv. :This OID indicates that the past 15-min Input Packet counter is invalid
1.3.6.1.4.1.20044.86.11.6.880.1.7Columnrm10001wbperfdatacomclientPast15StatInPacketCountPort1read-onlycurrentClient Past 15-min Input Packet counter :This OID gives the past 15-min Input Packet counter value
1.3.6.1.4.1.20044.86.11.6.880.1.28Columnrm10001wbperfdatacomclientPast15StatOutCrcCountInvPort1read-onlycurrentClient Past 15-min Output CRC counter inv. :This OID indicates that the past 15-min Output CRC counter is invalid
1.3.6.1.4.1.20044.86.11.6.880.1.29Columnrm10001wbperfdatacomclientPast15StatOutCrcCountPort1read-onlycurrentClient Past 15-min Output CRC counter :This OID gives the past 15-min Output CRC counter value
1.3.6.1.4.1.20044.86.11.6.880.1.30Columnrm10001wbperfdatacomclientPast15StatOutPacketCountInvPort1read-onlycurrentClient Past 15-min Output Packet counter inv. :This OID indicates that the past 15-min Output Packets counter is invalid
1.3.6.1.4.1.20044.86.11.6.880.1.31Columnrm10001wbperfdatacomclientPast15StatOutPacketCountPort1read-onlycurrentClient Past 15-min Output Packet counter :This OID gives the past 15-min Output Packets counter value
1.3.6.1.4.1.20044.86.11.6.912Tablerm10001wbPerfDatacomClientCurrent24StatTablenot-accessiblecurrentList of rm10001wbPerfDatacomClientCurrent24Stat Article
1.3.6.1.4.1.20044.86.11.6.912.1Rowrm10001wbPerfDatacomClientCurrent24StatEntrynot-accessiblecurrentRow definition for the rm10001wbPerfDatacomClientCurrent24Stat table
1.3.6.1.4.1.20044.86.11.6.912.1.1Columnrm10001wbPerfDatacomClientCurrent24StatIndexread-onlycurrentIndex definition for the rm10001wbPerfDatacomClientCurrent24Stat table
1.3.6.1.4.1.20044.86.11.6.912.1.4Columnrm10001wbperfdatacomclientCurrent24StatInCrcCountInvPortnread-onlycurrentClient Current 24-hours Input CRC counter inv. :This OID indicates that the current 24-hours Input CRC counter is invalid
1.3.6.1.4.1.20044.86.11.6.912.1.5Columnrm10001wbperfdatacomclientCurrent24StatInCrcCountPortnread-onlycurrentClient Current 24-hours Input CRC counter :This OID gives the current 24-hours Input CRC counter value
1.3.6.1.4.1.20044.86.11.6.912.1.6Columnrm10001wbperfdatacomclientCurrent24StatInPacketCountInvPortnread-onlycurrentClient Current 24-hours Input Packet counter inv. :This OID indicates that the current 24-hours Input Packet counter is invalid
1.3.6.1.4.1.20044.86.11.6.912.1.7Columnrm10001wbperfdatacomclientCurrent24StatInPacketCountPortnread-onlycurrentClient Current 24-hours Input Packet counter :This OID gives the current 24-hours Input Packet counter value
1.3.6.1.4.1.20044.86.11.6.912.1.28Columnrm10001wbperfdatacomclientCurrent24StatOutCrcCountInvPortnread-onlycurrentClient Current 24-hours Output CRC counter inv. :This OID indicates that the current 24-hours Output CRC counter is invalid
1.3.6.1.4.1.20044.86.11.6.912.1.29Columnrm10001wbperfdatacomclientCurrent24StatOutCrcCountPortnread-onlycurrentClient Current 24-hours Output CRC counter :This OID gives the current 24-hours Output CRC counter value
1.3.6.1.4.1.20044.86.11.6.912.1.30Columnrm10001wbperfdatacomclientCurrent24StatOutPacketCountInvPortnread-onlycurrentClient Current 24-hours Output Packet counter inv. :This OID indicates that the current 24-hours Output Packets counter is invalid
1.3.6.1.4.1.20044.86.11.6.912.1.31Columnrm10001wbperfdatacomclientCurrent24StatOutPacketCountPortnread-onlycurrentClient Current 24-hours Output Packet counter :This OID gives the current 24-hours Output Packets counter value
1.3.6.1.4.1.20044.86.11.6.944Tablerm10001wbPerfDatacomClientPast24StatHistoryPort1Tablenot-accessiblecurrentList of rm10001wbPerfDatacomClientPast24StatHistory Article
1.3.6.1.4.1.20044.86.11.6.944.1Rowrm10001wbPerfDatacomClientPast24StatHistoryPort1Entrynot-accessiblecurrentRow definition for the rm10001wbPerfDatacomClientPast24StatHistory table
1.3.6.1.4.1.20044.86.11.6.944.1.1Columnrm10001wbPerfDatacomClientPast24StatHistoryPort1Indexread-onlycurrentIndex definition for the rm10001wbPerfDatacomClientPast24StatHistory table
1.3.6.1.4.1.20044.86.11.6.944.1.4Columnrm10001wbperfdatacomclientPast24StatInCrcCountInvPort1read-onlycurrentClient Past 24-hours Input CRC counter inv. :This OID indicates that the past 24-hours Input CRC counter is invalid
1.3.6.1.4.1.20044.86.11.6.944.1.5Columnrm10001wbperfdatacomclientPast24StatInCrcCountPort1read-onlycurrentClient Past 24-hours Input CRC counter :This OID gives the past 24-hours Input CRC counter value
1.3.6.1.4.1.20044.86.11.6.944.1.6Columnrm10001wbperfdatacomclientPast24StatInPacketCountInvPort1read-onlycurrentClient Past 24-hours Input Packet counter inv. :This OID indicates that the past 24-hours Input Packet counter is invalid
1.3.6.1.4.1.20044.86.11.6.944.1.7Columnrm10001wbperfdatacomclientPast24StatInPacketCountPort1read-onlycurrentClient Past 24-hours Input Packet counter :This OID gives the past 24-hours Input Packet counter value
1.3.6.1.4.1.20044.86.11.6.944.1.28Columnrm10001wbperfdatacomclientPast24StatOutCrcCountInvPort1read-onlycurrentClient Past 24-hours Output CRC counter inv. :This OID indicates that the past 24-hours Output CRC counter is invalid
1.3.6.1.4.1.20044.86.11.6.944.1.29Columnrm10001wbperfdatacomclientPast24StatOutCrcCountPort1read-onlycurrentClient Past 24-hours Output CRC counter :This OID gives the past 24-hours Output CRC counter value
1.3.6.1.4.1.20044.86.11.6.944.1.30Columnrm10001wbperfdatacomclientPast24StatOutPacketCountInvPort1read-onlycurrentClient Past 24-hours Output Packet counter inv. :This OID indicates that the past 24-hours Output Packets counter is invalid
1.3.6.1.4.1.20044.86.11.6.944.1.31Columnrm10001wbperfdatacomclientPast24StatOutPacketCountPort1read-onlycurrentClient Past 24-hours Output Packet counter :This OID gives the past 24-hours Output Packets counter value
1.3.6.1.4.1.20044.86.11.7Noderm10001wbMonPerfLine
1.3.6.1.4.1.20044.86.11.7.336Tablerm10001wbPerfTelecomLinePostFecCurrent15StatTablenot-accessiblecurrentList of rm10001wbPerfTelecomLinePostFecCurrent15Stat Article
1.3.6.1.4.1.20044.86.11.7.336.1Rowrm10001wbPerfTelecomLinePostFecCurrent15StatEntrynot-accessiblecurrentRow definition for the rm10001wbPerfTelecomLinePostFecCurrent15Stat table
1.3.6.1.4.1.20044.86.11.7.336.1.1Columnrm10001wbPerfTelecomLinePostFecCurrent15StatIndexread-onlycurrentIndex definition for the rm10001wbPerfTelecomLinePostFecCurrent15Stat table
1.3.6.1.4.1.20044.86.11.7.336.1.2Columnrm10001wbPerfTelecomLinePostFecCurrent15StatInvCvPortnread-onlycurrentCurrent 15-min EBC counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.86.11.7.336.1.3Columnrm10001wbPerfTelecomLinePostFecCurrent15StatCvValuePortnread-onlycurrentCurrent 15-min EBC counter :This OID gives the current 15-min Coding Violation counter value
1.3.6.1.4.1.20044.86.11.7.336.1.4Columnrm10001wbPerfTelecomLinePostFecCurrent15StatInvEsPortnread-onlycurrentCurrent 15-min ES counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.7.336.1.5Columnrm10001wbPerfTelecomLinePostFecCurrent15StatEsValuePortnread-onlycurrentCurrent 15-min ES counter :This OID gives the current 15-min Errored Second counter value
1.3.6.1.4.1.20044.86.11.7.336.1.6Columnrm10001wbPerfTelecomLinePostFecCurrent15StatInvSesPortnread-onlycurrentCurrent 15-min SES counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.7.336.1.7Columnrm10001wbPerfTelecomLinePostFecCurrent15StatSesValuePortnread-onlycurrentCurrent 15-min SES counter :This OID gives the current 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.86.11.7.336.1.8Columnrm10001wbPerfTelecomLinePostFecCurrent15StatInvSefsPortnread-onlycurrentCurrent 15-min SEFS counter inv. :This OID indicates that the current 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.86.11.7.336.1.9Columnrm10001wbPerfTelecomLinePostFecCurrent15StatSefsValuePortnread-onlycurrentCurrent 15-min SEFS counter :This OID gives the current 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.86.11.7.336.1.10Columnrm10001wbPerfTelecomLinePostFecCurrent15StatInvUasPortnread-onlycurrentCurrent 15-min UAS counter inv. :This OID indicates that the current 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.86.11.7.336.1.11Columnrm10001wbPerfTelecomLinePostFecCurrent15StatUasValuePortnread-onlycurrentCurrent 15-min UAS counter :This OID gives the current 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.86.11.7.337Tablerm10001wbPerfTelecomLinePostFecPast15StatHistoryPort1Tablenot-accessiblecurrentList of rm10001wbPerfTelecomLinePostFecPast15StatHistory Article
1.3.6.1.4.1.20044.86.11.7.337.1Rowrm10001wbPerfTelecomLinePostFecPast15StatHistoryPort1Entrynot-accessiblecurrentRow definition for the rm10001wbPerfTelecomLinePostFecPast15StatHistory table
1.3.6.1.4.1.20044.86.11.7.337.1.1Columnrm10001wbPerfTelecomLinePostFecPast15StatHistoryPort1Indexread-onlycurrentIndex definition for the rm10001wbPerfTelecomLinePostFecPast15StatHistory table
1.3.6.1.4.1.20044.86.11.7.337.1.2Columnrm10001wbPerfTelecomLinePostFecPast15StatHistoryInvCvPort1read-onlycurrentPrevious 15-min EBC counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.86.11.7.337.1.3Columnrm10001wbPerfTelecomLinePostFecPast15StatHistoryCvValuePort1read-onlycurrentPrevious 15-min EBC counter :This OID gives the previous 15-min Coding Violation counter value
1.3.6.1.4.1.20044.86.11.7.337.1.4Columnrm10001wbPerfTelecomLinePostFecPast15StatHistoryInvEsPort1read-onlycurrentPrevious 15-min ES counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.7.337.1.5Columnrm10001wbPerfTelecomLinePostFecPast15StatHistoryEsValuePort1read-onlycurrentPrevious 15-min ES counter :This OID gives the previous 15-min Errored Second counter value
1.3.6.1.4.1.20044.86.11.7.337.1.6Columnrm10001wbPerfTelecomLinePostFecPast15StatHistoryInvSesPort1read-onlycurrentPrevious 15-min SES counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.7.337.1.7Columnrm10001wbPerfTelecomLinePostFecPast15StatHistorySesValuePort1read-onlycurrentPrevious 15-min SES counter :This OID gives the previous 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.86.11.7.337.1.8Columnrm10001wbPerfTelecomLinePostFecPast15StatHistoryInvSefsPort1read-onlycurrentPrevious 15-min SEFS counter inv. :This OID indicates that the previous 15-min severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.86.11.7.337.1.9Columnrm10001wbPerfTelecomLinePostFecPast15StatHistorySefsValuePort1read-onlycurrentPrevious 15-min SEFS counter :This OID gives the previous 15-min severely Errored Framing Second counter value
1.3.6.1.4.1.20044.86.11.7.337.1.10Columnrm10001wbPerfTelecomLinePostFecPast15StatHistoryInvUasPort1read-onlycurrentPrevious 15-min UAS counter inv. :This OID indicates that the previous 15-min UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.86.11.7.337.1.11Columnrm10001wbPerfTelecomLinePostFecPast15StatHistoryUasValuePort1read-onlycurrentPrevious 15-min UAS counter :This OID gives the previous 15-min UnAvailable Second counter value
1.3.6.1.4.1.20044.86.11.7.338Tablerm10001wbPerfTelecomLinePostFecCurrent24StatTablenot-accessiblecurrentList of rm10001wbPerfTelecomLinePostFecCurrent24Stat Article
1.3.6.1.4.1.20044.86.11.7.338.1Rowrm10001wbPerfTelecomLinePostFecCurrent24StatEntrynot-accessiblecurrentRow definition for the rm10001wbPerfTelecomLinePostFecCurrent24Stat table
1.3.6.1.4.1.20044.86.11.7.338.1.1Columnrm10001wbPerfTelecomLinePostFecCurrent24StatIndexread-onlycurrentIndex definition for the rm10001wbPerfTelecomLinePostFecCurrent24Stat table
1.3.6.1.4.1.20044.86.11.7.338.1.2Columnrm10001wbPerfTelecomLinePostFecCurrent24StatInvCvPortnread-onlycurrentCurrent 24-hours EBC counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.86.11.7.338.1.3Columnrm10001wbPerfTelecomLinePostFecCurrent24StatCvValuePortnread-onlycurrentCurrent 24-hours EBC counter :This OID gives the current 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.86.11.7.338.1.4Columnrm10001wbPerfTelecomLinePostFecCurrent24StatInvEsPortnread-onlycurrentCurrent 24-hours ES counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.7.338.1.5Columnrm10001wbPerfTelecomLinePostFecCurrent24StatEsValuePortnread-onlycurrentCurrent 24-hours ES counter :This OID gives the current 24-hours Errored Second counter value
1.3.6.1.4.1.20044.86.11.7.338.1.6Columnrm10001wbPerfTelecomLinePostFecCurrent24StatInvSesPortnread-onlycurrentCurrent 24-hours SES counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.7.338.1.7Columnrm10001wbPerfTelecomLinePostFecCurrent24StatSesValuePortnread-onlycurrentCurrent 24-hours SES counter :This OID gives the current 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.86.11.7.338.1.8Columnrm10001wbPerfTelecomLinePostFecCurrent24StatInvSefsPortnread-onlycurrentCurrent 24-hours SEFS counter inv. :This OID indicates that the current 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.86.11.7.338.1.9Columnrm10001wbPerfTelecomLinePostFecCurrent24StatSefsValuePortnread-onlycurrentCurrent 24-hours SEFS counter :This OID gives the current 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.86.11.7.338.1.10Columnrm10001wbPerfTelecomLinePostFecCurrent24StatInvUasPortnread-onlycurrentCurrent 24-hours UAS counter inv. :This OID indicates that the current 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.86.11.7.338.1.11Columnrm10001wbPerfTelecomLinePostFecCurrent24StatUasValuePortnread-onlycurrentCurrent 24-hours UAS counter :This OID gives the current 24-hours UnAvailable Second counter value
1.3.6.1.4.1.20044.86.11.7.339Tablerm10001wbPerfTelecomLinePostFecPast24StatHistoryPort1Tablenot-accessiblecurrentList of rm10001wbPerfTelecomLinePostFecPast24StatHistory Article
1.3.6.1.4.1.20044.86.11.7.339.1Rowrm10001wbPerfTelecomLinePostFecPast24StatHistoryPort1Entrynot-accessiblecurrentRow definition for the rm10001wbPerfTelecomLinePostFecPast24StatHistory table
1.3.6.1.4.1.20044.86.11.7.339.1.1Columnrm10001wbPerfTelecomLinePostFecPast24StatHistoryPort1Indexread-onlycurrentIndex definition for the rm10001wbPerfTelecomLinePostFecPast24StatHistory table
1.3.6.1.4.1.20044.86.11.7.339.1.2Columnrm10001wbPerfTelecomLinePostFecPast24StatHistoryInvCvPort1read-onlycurrentPrevious 24-hours EBC counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.86.11.7.339.1.3Columnrm10001wbPerfTelecomLinePostFecPast24StatHistoryCvValuePort1read-onlycurrentPrevious 24-hours EBC counter :This OID gives the previous 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.86.11.7.339.1.4Columnrm10001wbPerfTelecomLinePostFecPast24StatHistoryInvEsPort1read-onlycurrentPrevious 24-hours ES counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.7.339.1.5Columnrm10001wbPerfTelecomLinePostFecPast24StatHistoryEsValuePort1read-onlycurrentPrevious 24-hours ES counter :This OID gives the previous 24-hours Errored Second counter value
1.3.6.1.4.1.20044.86.11.7.339.1.6Columnrm10001wbPerfTelecomLinePostFecPast24StatHistoryInvSesPort1read-onlycurrentPrevious 24-hours SES counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.7.339.1.7Columnrm10001wbPerfTelecomLinePostFecPast24StatHistorySesValuePort1read-onlycurrentPrevious 24-hours SES counter :This OID gives the previous 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.86.11.7.339.1.8Columnrm10001wbPerfTelecomLinePostFecPast24StatHistoryInvSefsPort1read-onlycurrentPrevious 24-hours SEFS counter inv. :This OID indicates that the previous 24-hours severely Errored Framing Second counter is invalid
1.3.6.1.4.1.20044.86.11.7.339.1.9Columnrm10001wbPerfTelecomLinePostFecPast24StatHistorySefsValuePort1read-onlycurrentPrevious 24-hours SEFS counter :This OID gives the previous 24-hours severely Errored Framing Second counter value
1.3.6.1.4.1.20044.86.11.7.339.1.10Columnrm10001wbPerfTelecomLinePostFecPast24StatHistoryInvUasPort1read-onlycurrentPrevious 24-hours UAS counter inv. :This OID indicates that the previous 24-hours UnAvailable Second counter is invalid
1.3.6.1.4.1.20044.86.11.7.339.1.11Columnrm10001wbPerfTelecomLinePostFecPast24StatHistoryUasValuePort1read-onlycurrentPrevious 24-hours UAS counter :This OID gives the previous 24-hours UnAvailable Second counter value
1.3.6.1.4.1.20044.86.11.7.352Tablerm10001wbPerfTelecomBerLinePreFecCurrent15StatTablenot-accessiblecurrentList of rm10001wbPerfTelecomBerLinePreFecCurrent15Stat Article
1.3.6.1.4.1.20044.86.11.7.352.1Rowrm10001wbPerfTelecomBerLinePreFecCurrent15StatEntrynot-accessiblecurrentRow definition for the rm10001wbPerfTelecomBerLinePreFecCurrent15Stat table
1.3.6.1.4.1.20044.86.11.7.352.1.1Columnrm10001wbPerfTelecomBerLinePreFecCurrent15StatIndexread-onlycurrentIndex definition for the rm10001wbPerfTelecomBerLinePreFecCurrent15Stat table
1.3.6.1.4.1.20044.86.11.7.352.1.2Columnrm10001wbPerfTelecomBerLinePreFecCurrent15StatInvBerPortnread-onlycurrentCurrent 15-min BER counter inv. :This OID indicates that the current 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.86.11.7.352.1.3Columnrm10001wbPerfTelecomBerLinePreFecCurrent15StatBerValuePortnread-onlycurrentCurrent 15-min BER counter :This OID gives the current 15-min Coding Violation counter value
1.3.6.1.4.1.20044.86.11.7.352.1.4Columnrm10001wbPerfTelecomBerLinePreFecCurrent15StatInvMinBerPortnread-onlycurrentCurrent 15-min MinBER counter inv. :This OID indicates that the current 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.7.352.1.5Columnrm10001wbPerfTelecomBerLinePreFecCurrent15StatMinBerValuePortnread-onlycurrentCurrent 15-min MinBER counter :This OID gives the current 15-min Errored Second counter value
1.3.6.1.4.1.20044.86.11.7.352.1.6Columnrm10001wbPerfTelecomBerLinePreFecCurrent15StatInvMaxBerPortnread-onlycurrentCurrent 15-min MaxBER counter inv. :This OID indicates that the current 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.7.352.1.7Columnrm10001wbPerfTelecomBerLinePreFecCurrent15StatMaxBerValuePortnread-onlycurrentCurrent 15-min MaxBER counter :This OID gives the current 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.86.11.7.353Tablerm10001wbPerfTelecomBerLinePreFecPast15StatHistoryPort1Tablenot-accessiblecurrentList of rm10001wbPerfTelecomBerLinePreFecPast15StatHistory Article
1.3.6.1.4.1.20044.86.11.7.353.1Rowrm10001wbPerfTelecomBerLinePreFecPast15StatHistoryPort1Entrynot-accessiblecurrentRow definition for the rm10001wbPerfTelecomBerLinePreFecPast15StatHistory table
1.3.6.1.4.1.20044.86.11.7.353.1.1Columnrm10001wbPerfTelecomBerLinePreFecPast15StatHistoryPort1Indexread-onlycurrentIndex definition for the rm10001wbPerfTelecomBerLinePreFecPast15StatHistory table
1.3.6.1.4.1.20044.86.11.7.353.1.2Columnrm10001wbPerfTelecomBerLinePreFecPast15StatHistoryInvBerPort1read-onlycurrentPrevious 15-min BER counter inv. :This OID indicates that the previous 15-min Coding Violation counter is invalid
1.3.6.1.4.1.20044.86.11.7.353.1.3Columnrm10001wbPerfTelecomBerLinePreFecPast15StatHistoryBerValuePort1read-onlycurrentPrevious 15-min BER counter :This OID gives the previous 15-min Coding Violation counter value
1.3.6.1.4.1.20044.86.11.7.353.1.4Columnrm10001wbPerfTelecomBerLinePreFecPast15StatHistoryInvMinBerPort1read-onlycurrentPrevious 15-min MinBER counter inv. :This OID indicates that the previous 15-min Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.7.353.1.5Columnrm10001wbPerfTelecomBerLinePreFecPast15StatHistoryMinBerValuePort1read-onlycurrentPrevious 15-min MinBER counter :This OID gives the previous 15-min Errored Second counter value
1.3.6.1.4.1.20044.86.11.7.353.1.6Columnrm10001wbPerfTelecomBerLinePreFecPast15StatHistoryInvMaxBerPort1read-onlycurrentPrevious 15-min MaxBER counter inv. :This OID indicates that the previous 15-min severely Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.7.353.1.7Columnrm10001wbPerfTelecomBerLinePreFecPast15StatHistoryMaxBerValuePort1read-onlycurrentPrevious 15-min MaxBER counter :This OID gives the previous 15-min severely Errored Second counter value
1.3.6.1.4.1.20044.86.11.7.354Tablerm10001wbPerfTelecomBerLinePreFecCurrent24StatTablenot-accessiblecurrentList of rm10001wbPerfTelecomBerLinePreFecCurrent24Stat Article
1.3.6.1.4.1.20044.86.11.7.354.1Rowrm10001wbPerfTelecomBerLinePreFecCurrent24StatEntrynot-accessiblecurrentRow definition for the rm10001wbPerfTelecomBerLinePreFecCurrent24Stat table
1.3.6.1.4.1.20044.86.11.7.354.1.1Columnrm10001wbPerfTelecomBerLinePreFecCurrent24StatIndexread-onlycurrentIndex definition for the rm10001wbPerfTelecomBerLinePreFecCurrent24Stat table
1.3.6.1.4.1.20044.86.11.7.354.1.2Columnrm10001wbPerfTelecomBerLinePreFecCurrent24StatInvBerPortnread-onlycurrentCurrent 24-hours BER counter inv. :This OID indicates that the current 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.86.11.7.354.1.3Columnrm10001wbPerfTelecomBerLinePreFecCurrent24StatBerValuePortnread-onlycurrentCurrent 24-hours BER counter :This OID gives the current 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.86.11.7.354.1.4Columnrm10001wbPerfTelecomBerLinePreFecCurrent24StatInvMinBerPortnread-onlycurrentCurrent 24-hoursMinBER counter inv. :This OID indicates that the current 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.7.354.1.5Columnrm10001wbPerfTelecomBerLinePreFecCurrent24StatMinBerValuePortnread-onlycurrentCurrent 24-hours MinBER counter :This OID gives the current 24-hours Errored Second counter value
1.3.6.1.4.1.20044.86.11.7.354.1.6Columnrm10001wbPerfTelecomBerLinePreFecCurrent24StatInvMaxBerPortnread-onlycurrentCurrent 24-hours MaxBER counter inv. :This OID indicates that the current 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.7.354.1.7Columnrm10001wbPerfTelecomBerLinePreFecCurrent24StatMaxBerValuePortnread-onlycurrentCurrent 24-hours MaxBER counter :This OID gives the current 24-hours severely Errored Second counter value
1.3.6.1.4.1.20044.86.11.7.355Tablerm10001wbPerfTelecomBerLinePreFecPast24StatHistoryPort1Tablenot-accessiblecurrentList of rm10001wbPerfTelecomBerLinePreFecPast24StatHistory Article
1.3.6.1.4.1.20044.86.11.7.355.1Rowrm10001wbPerfTelecomBerLinePreFecPast24StatHistoryPort1Entrynot-accessiblecurrentRow definition for the rm10001wbPerfTelecomBerLinePreFecPast24StatHistory table
1.3.6.1.4.1.20044.86.11.7.355.1.1Columnrm10001wbPerfTelecomBerLinePreFecPast24StatHistoryPort1Indexread-onlycurrentIndex definition for the rm10001wbPerfTelecomBerLinePreFecPast24StatHistory table
1.3.6.1.4.1.20044.86.11.7.355.1.2Columnrm10001wbPerfTelecomBerLinePreFecPast24StatHistoryInvBerPort1read-onlycurrentPrevious 24-hours BER counter inv. :This OID indicates that the previous 24-hours Coding Violation counter is invalid
1.3.6.1.4.1.20044.86.11.7.355.1.3Columnrm10001wbPerfTelecomBerLinePreFecPast24StatHistoryBerValuePort1read-onlycurrentPrevious 24-hours BER counter :This OID gives the previous 24-hours Coding Violation counter value
1.3.6.1.4.1.20044.86.11.7.355.1.4Columnrm10001wbPerfTelecomBerLinePreFecPast24StatHistoryInvMinBerPort1read-onlycurrentPrevious 24-hours MinBER counter inv. :This OID indicates that the previous 24-hours Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.7.355.1.5Columnrm10001wbPerfTelecomBerLinePreFecPast24StatHistoryMinBerValuePort1read-onlycurrentPrevious 24-hours MinBER counter :This OID gives the previous 24-hours Errored Second counter value
1.3.6.1.4.1.20044.86.11.7.355.1.6Columnrm10001wbPerfTelecomBerLinePreFecPast24StatHistoryInvMaxBerPort1read-onlycurrentPrevious 24-hours MaxBER counter inv. :This OID indicates that the previous 24-hours severely Errored Second counter is invalid
1.3.6.1.4.1.20044.86.11.7.355.1.7Columnrm10001wbPerfTelecomBerLinePreFecPast24StatHistoryMaxBerValuePort1read-onlycurrentPrevious 24-hours MaxBER counter :This OID gives the previous 24-hours severely Errored Second counter value
Type Definitions
NameSyntaxStatusDescription
Rm10001wbAdjustValueINTEGER { otxadjustvalue0(0), otxadjustvalue1(1), otxadjustvalue2(2), otxadjustvalue3(3), otxadjustvalue4(4), otxadjustvalue5(5), otxadjustvalue6(6), otxadjustvalue7(7), otxadjustvalue8(8), otxadjustvalue9(9), otxadjustvalue10(10) }currentDifferent values in Adjust mode on OTX-TLH on client and line ports
Rm10001wbClientProtocolINTEGER { protocolclientvalue0(0), protocolclientvalue1(1), protocolclientvalue2(2), protocolclientvalue3(3), protocolclientvalue4(4), protocolclientvalue5(5), protocolclientvalue6(6), protocolclientvalue7(7), protocolclientvalue8(8) }currentDifferent values on the protocol on the client ports
Rm10001wbDccModeINTEGER { dccNo(0), dccLine1(1), dccLine2(2) }currentMode for DCC
Rm10001wbMultiRateINTEGER { rate100Mhz(0), rate250Mhz(1), rate500Mhz(2), rate1Ghz(3) }currentdifferent rate for a client port
Rm10001wbOrxChannelINTEGERcurrentChannel selection on transceiver Rx line ports
Rm10001wbOtxChannelINTEGERcurrentChannel selection on transceiver Tx line ports
Rm10001wbOtxGridINTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50) }currentDifferent grids on OTX-TLH on client and line ports
Rm10001wbOtxModeINTEGER { otx80mode(1), otx60mode(2), otxadjustmode(4) }currentDifferent modes on OTX-TLH on client and line ports
Rm10001wbProtocolModeINTEGER { protocolmodevalue0(0), protocolmodevalue1(1), protocolmodevalue2(2), protocolmodevalue3(3) }currentDifferent values on the protocol mode