EKINOPS-Rm10010e40-MIB
703 objects
Creation.
Imported Objects
| EKINOPS-MIB | EkiApiState EkiMeasureType EkiMode ekinops EkiOnOff EkiProtocol EkiState EkiSynchroMode |
| SNMPv2-SMI | Counter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20044.57 | IdentitymoduleRm10010e40 | Creation. | ||
| 1.3.6.1.4.1.20044.57.2 | Noderm10010e40alarms | |||
| 1.3.6.1.4.1.20044.57.2.1 | Noderm10010e40AlmOther | |||
| 1.3.6.1.4.1.20044.57.2.1.1 | Noderm10010e40AlmOtherNurg | |||
| 1.3.6.1.4.1.20044.57.2.1.1.2 | Noderm10010e40AlmsynthAlm2 | |||
| 1.3.6.1.4.1.20044.57.2.1.1.2.1 | Scalarrm10010e40AlmConfTableSave | read-only | current | PM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> infor… |
| 1.3.6.1.4.1.20044.57.2.1.1.2.2 | Scalarrm10010e40AlmInvUpload | read-only | current | Inventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> informationalStatus(1000) <Alarmtype> ot… |
| 1.3.6.1.4.1.20044.57.2.1.1.2.3 | Scalarrm10010e40AlmConfTableLoad | read-only | current | PM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> informationalStat… |
| 1.3.6.1.4.1.20044.57.2.1.1.2.4 | Scalarrm10010e40AlmCorrelatOff | read-only | current | Not Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> informationalStatus(1000) <Alarmtype… |
| 1.3.6.1.4.1.20044.57.2.1.1.2.5 | Scalarrm10010e40AlmMaintenanceOn | read-only | current | Maintenance Mode :This OID indicates that the RM is in maintenance mode. <Help> This alarm indicates that the maintenance mode is enabled on the PM <Condtype> … |
| 1.3.6.1.4.1.20044.57.2.1.2 | Noderm10010e40AlmOtherUrg | |||
| 1.3.6.1.4.1.20044.57.2.1.2.248 | Noderm10010e40AlmmodFanFail | |||
| 1.3.6.1.4.1.20044.57.2.1.2.248.1 | Scalarrm10010e40AlmFanModuleAbsent | read-only | current | Fan Module Absent :This OID indicates the presence of the FAN module in the Chassis. <Help> This alarm indicates if the FAN module is detected in the chassis. … |
| 1.3.6.1.4.1.20044.57.2.1.2.248.2 | Scalarrm10010e40AlmFansFail | read-only | current | Fan Module Failure :This OID indicates that at least one of the 4 FAN unit of the FAN module is in fail condition <Help> This alarm indicates if one the FANs i… |
| 1.3.6.1.4.1.20044.57.2.1.2.248.4 | Scalarrm10010e40AlmFan1Fail | read-only | current | Fan Unit N�1 Failed On Fan Module :This OID indicates a failure on fan 1. Removal of the fan unit or no rotation sets the OID. <Help> This alarm indicates if… |
| 1.3.6.1.4.1.20044.57.2.1.2.248.5 | Scalarrm10010e40AlmFan2Fail | read-only | current | Fan Unit N�2 Failed On Fan Module :This OID indicates a failure on fan 2. Removal of the fan unit or no rotation sets the OID. <Help> This alarm indicates if… |
| 1.3.6.1.4.1.20044.57.2.1.2.248.6 | Scalarrm10010e40AlmFan3Fail | read-only | current | Fan Unit N�3 Failed On Fan Module :This OID indicates a failure on fan 3. Removal of the fan unit or no rotation sets the OID. <Help> This alarm indicates if… |
| 1.3.6.1.4.1.20044.57.2.1.2.248.7 | Scalarrm10010e40AlmFan4Fail | read-only | current | Fan Unit N�4 Failed On Fan Module :This OID indicates a failure on fan 4. Removal of the fan unit or no rotation sets the OID. <Help> This alarm indicates if… |
| 1.3.6.1.4.1.20044.57.2.1.3 | Noderm10010e40AlmOtherCrit | |||
| 1.3.6.1.4.1.20044.57.2.1.3.0 | Noderm10010e40AlmsynthAlm0 | |||
| 1.3.6.1.4.1.20044.57.2.1.3.0.2 | Scalarrm10010e40AlmFailFan | read-only | current | Fan Fail :This OID is at 1 when any fail occurs on the fan tray <Help> This alarm indicates that the Fan tray module is in a failure condition <Condtype> FAIL_… |
| 1.3.6.1.4.1.20044.57.2.1.3.0.9 | Scalarrm10010e40AlmModGlobFail | read-only | current | Module Failure :This OID is set on detection of a failure originating from the RM <Help> This alarm is set on detection of a failure originating from the equip… |
| 1.3.6.1.4.1.20044.57.2.1.3.0.15 | Scalarrm10010e40AlmDefFuseA | read-only | current | Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.57.2.1.3.0.16 | Scalarrm10010e40AlmDefFuseB | read-only | current | Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.57.2.1.3.40 | Noderm10010e40AlmclientModuleState | |||
| 1.3.6.1.4.1.20044.57.2.1.3.40.1 | Scalarrm10010e40AlmCfpInitialize | read-only | current | Client Trscv Initialize :This OID indicates the Client Trscv initialization is in progress <Help> Status indicating the Client Trscv initialization is in progr… |
| 1.3.6.1.4.1.20044.57.2.1.3.40.2 | Scalarrm10010e40AlmCfpLowPower | read-only | current | Client Trscv Low Power :This OID indicates the Client Trscv is in low power state <Help> Status indicating the Client Trscv is in low power state <Condtype> CF… |
| 1.3.6.1.4.1.20044.57.2.1.3.40.3 | Scalarrm10010e40AlmCfpHighPowerUp | read-only | current | Client Trscv High Power Up :This OID indicates the Client Trscv is leaving Low Power state <Help> Status indicating the Client Trscv is leaving Low Power state… |
| 1.3.6.1.4.1.20044.57.2.1.3.40.4 | Scalarrm10010e40AlmCfpTxOff | read-only | current | Client Trscv Laser Shutdown :This OID indicates the Client Trscv Laser is OFF <Help> Status indicating the Client Trscv Laser is OFF <Condtype> CFP_TX_OFF <Pro… |
| 1.3.6.1.4.1.20044.57.2.1.3.40.5 | Scalarrm10010e40AlmCfpTxTurnOn | read-only | current | Client Trscv Laser Turn On :This OID indicates the Client Trscv is turning on its laser <Help> Status indicating the Client Trscv is turning on its laser <Cond… |
| 1.3.6.1.4.1.20044.57.2.1.3.40.6 | Scalarrm10010e40AlmCfpReady | read-only | current | Client Trscv Ready :This OID indicates the Client Trscv is ready to operate <Help> Status indicating the Client Trscv is ready to operate <Condtype> CFP_READY … |
| 1.3.6.1.4.1.20044.57.2.1.3.40.7 | Scalarrm10010e40AlmCfpFault | read-only | current | Client Trscv Fault :This OID indicates the Client Trscv is in Fault state <Help> Status indicating the Client Trscv is in Fault state <Condtype> CFP_FAULT <Pro… |
| 1.3.6.1.4.1.20044.57.2.1.3.40.8 | Scalarrm10010e40AlmCfpTxTurnOff | read-only | current | Client Trscv Laser Turn Off :This OID indicates the Client Trscv is turning off its laser <Help> Status indicating the Client Trscv is turning off its laser <C… |
| 1.3.6.1.4.1.20044.57.2.1.3.40.9 | Scalarrm10010e40AlmCfpHighPowerDown | read-only | current | Client Trscv High Power Down :This OID indicates the Client Trscv is entering Low Power state <Help> Status indicating the Client Trscv is entering Low Power s… |
| 1.3.6.1.4.1.20044.57.2.1.3.41 | Noderm10010e40AlmclientModuleGeneralStatus | |||
| 1.3.6.1.4.1.20044.57.2.1.3.41.4 | Scalarrm10010e40AlmCfpOutOfAlignment | read-only | current | Client Trscv Out Of Alignment :This OID indicates an Out of alignment on the Client Trscv Host Interface <Help> Alarm indicating an Out of alignment on the Cli… |
| 1.3.6.1.4.1.20044.57.2.1.3.41.5 | Scalarrm10010e40AlmCfpRxNetworkLol | read-only | current | Client Trscv Rx Network Loss Of Lock :This OID indicates of Loss of Lock is dected on the Client Trscv Rx Network interface <Help> Alarm indicating of Loss of … |
| 1.3.6.1.4.1.20044.57.2.1.3.41.6 | Scalarrm10010e40AlmCfpRxLos | read-only | current | Client Trscv Loss Of Signal :This OID indicates a Loss of Signal is detected on the Client Trscv <Help> Alarm indicating a Loss of Signal is detected on the Cl… |
| 1.3.6.1.4.1.20044.57.2.1.3.41.7 | Scalarrm10010e40AlmCfpTxHostLol | read-only | current | Client Trscv Tx Host Loss Of Lock :This OID indicates of Loss of Lock is detected on the Client Trscv Tx Host interface <Help> Alarm indicating of Loss of Lock… |
| 1.3.6.1.4.1.20044.57.2.1.3.41.8 | Scalarrm10010e40AlmCfpTxLosf | read-only | current | Client Trscv Loss Of Signal Functionality :This OID indicates a Loss of Signal functionality is detected on the Client Trscv <Help> Alarm indicating a Loss of … |
| 1.3.6.1.4.1.20044.57.2.1.3.41.9 | Scalarrm10010e40AlmCfpTxCmuLol | read-only | current | Client Trscv CMU Loss Of Lock :This OID indicates a Clock Multiplier Unit Loss of Lock is detected on the Client Trscv <Help> Alarm indicating a Clock Multipli… |
| 1.3.6.1.4.1.20044.57.2.1.3.41.10 | Scalarrm10010e40AlmCfpTxJitterPllLol | read-only | current | Client Trscv Tx Jitter PLL Loss Of Lock :This OID indicates a Tx Jitter PLL Loss of Lock is dtected on the Client Trscv <Help> Alarm indicating a Tx Jitter PLL… |
| 1.3.6.1.4.1.20044.57.2.1.3.41.11 | Scalarrm10010e40AlmCfpLossOfRefclk | read-only | current | Client Trscv Loss Of Ref Clock :This OID indicates a Loss of Reference clock is detected on the Client Trscv <Help> Alarm indicating a Loss of Reference clock … |
| 1.3.6.1.4.1.20044.57.2.1.3.41.14 | Scalarrm10010e40AlmCfpHwInterlock | read-only | current | Client Trscv Hardware Interlock :This OID indicates the Client Trscv power is higher than the cooling capacity <Help> Alarm indicating the Client Trscv power i… |
| 1.3.6.1.4.1.20044.57.2.1.3.42 | Noderm10010e40AlmclientGlobalAlarmSummary | |||
| 1.3.6.1.4.1.20044.57.2.1.3.42.1 | Scalarrm10010e40AlmCfpSoftGlobAlarmTest | read-only | current | Client Trscv Global Alarm SW Test :This OID indicates the Client Trscv Global Alarm This OID is raised by SW request for test purpose <Help> Status indicating … |
| 1.3.6.1.4.1.20044.57.2.1.3.42.7 | Scalarrm10010e40AlmCfpNetworkLaneAlarmWarning2 | read-only | current | Client Trscv Network Alarm And Warning 2 :This OID indicates at least one DDM is detected on the Client Trscv Network Interface <Help> Synthesis alarm indicati… |
| 1.3.6.1.4.1.20044.57.2.1.3.42.8 | Scalarrm10010e40AlmCfpModuleState | read-only | current | Client Trscv Module State :This OID indicates the Client Trscv module state <Help> Synthesis alarm indicating the Client Trscv module state <Condtype> CFP_MODU… |
| 1.3.6.1.4.1.20044.57.2.1.3.42.9 | Scalarrm10010e40AlmCfpModuleGeneralStatus | read-only | current | Client Trscv General Status :This OID indicates the Client Trscv module general status <Help> Synthesis alarm indicating the Client Trscv module general status… |
| 1.3.6.1.4.1.20044.57.2.1.3.42.10 | Scalarrm10010e40AlmCfpModuleFault | read-only | current | Client Trscv Module Fault :This OID indicates at least one Fault is detected on the Client Trscv module <Help> Synthesis alarm indicating at least one Fault is… |
| 1.3.6.1.4.1.20044.57.2.1.3.42.11 | Scalarrm10010e40AlmCfpModuleAlarmWarning1 | read-only | current | Client Trscv Module Alarm And Warning 1 :This OID indicates at least one DDM This OID is detected on the Client Trscv module <Help> Synthesis alarm indicating … |
| 1.3.6.1.4.1.20044.57.2.1.3.42.12 | Scalarrm10010e40AlmCfpModuleAlarmWarning2 | read-only | current | Client Trscv Module Alarm And Warning 2 :This OID indicates at least one DDM is detected on the Client Trscv module <Help> Synthesis alarm indicating at least … |
| 1.3.6.1.4.1.20044.57.2.1.3.42.13 | Scalarrm10010e40AlmCfpNetworkLaneAlarmWarning1 | read-only | current | Client Trscv Network Alarm And Warning 1 :This OID indicates at least one DDM is detected on the Client Trscv Network Interface <Help> Synthesis alarm indicati… |
| 1.3.6.1.4.1.20044.57.2.1.3.42.14 | Scalarrm10010e40AlmCfpNetworkLaneFaultStatus | read-only | current | Client Trscv Network Fault And Status :This OID indicates at least one Fault or Status is detected on the Client Trscv Network Interface <Help> Synthesis alarm… |
| 1.3.6.1.4.1.20044.57.2.1.3.42.15 | Scalarrm10010e40AlmCfpHostLaneFaultStatus | read-only | current | Client Trscv Host Fault And Status :This OID indicates at least one Fault or Status is detected on the Client Trscv Host Interface <Help> Synthesis alarm indic… |
| 1.3.6.1.4.1.20044.57.2.1.3.42.16 | Scalarrm10010e40AlmCfpGlobAlarmAssertion | read-only | current | Client Trscv Global Alarm :This OID indicates at least one Fault or Status is detected on the Client Trscv module <Help> Synthesis alarm indicating at least on… |
| 1.3.6.1.4.1.20044.57.2.1.3.46 | Noderm10010e40AlmmsaModuleState | |||
| 1.3.6.1.4.1.20044.57.2.1.3.46.1 | Scalarrm10010e40AlmMsaInitialize | read-only | current | Line Trscv Initialize :This OID indicates the Line Trscv initialization is in progress <Help> Status indicating the Line Trscv initialization is in progress <C… |
| 1.3.6.1.4.1.20044.57.2.1.3.46.2 | Scalarrm10010e40AlmMsaLowPower | read-only | current | Line Trscv Low Power :This OID indicates the Line Trscv is in low power state <Help> Status indicating the Line Trscv is in low power state <Condtype> MSA_LOW_… |
| 1.3.6.1.4.1.20044.57.2.1.3.46.3 | Scalarrm10010e40AlmMsaHighPowerUp | read-only | current | Line Trscv High Power Up :This OID indicates the Line Trscv is leaving Low Power state <Help> Status indicating the Line Trscv is leaving Low Power state <Cond… |
| 1.3.6.1.4.1.20044.57.2.1.3.46.4 | Scalarrm10010e40AlmMsaTxOff | read-only | current | Line Trscv Laser Shutdown :This OID indicates the Line Trscv Laser is OFF <Help> Status indicating the Line Trscv Laser is OFF <Condtype> MSA_TX_OFF <Probcause… |
| 1.3.6.1.4.1.20044.57.2.1.3.46.5 | Scalarrm10010e40AlmMsaTxTurnOn | read-only | current | Line Trscv Laser Turn On :This OID indicates the Line Trscv is turning on its laser <Help> Status indicating the Line Trscv is turning on its laser <Condtype> … |
| 1.3.6.1.4.1.20044.57.2.1.3.46.6 | Scalarrm10010e40AlmMsaReady | read-only | current | Line Trscv Ready :This OID indicates the Line Trscv is ready to operate <Help> Status indicating the Line Trscv is ready to operate <Condtype> MSA_READY <Probc… |
| 1.3.6.1.4.1.20044.57.2.1.3.46.7 | Scalarrm10010e40AlmMsaFault | read-only | current | Line Trscv Fault :This OID indicates the Line Trscv is in Fault state <Help> Status indicating the Line Trscv is in Fault state <Condtype> MSA_FAULT <Probcause… |
| 1.3.6.1.4.1.20044.57.2.1.3.46.8 | Scalarrm10010e40AlmMsaTxTurnOff | read-only | current | Line Trscv Laser Turn Off :This OID indicates the Line Trscv is turning off its laser <Help> Status indicating the Line Trscv is turning off its laser <Condtyp… |
| 1.3.6.1.4.1.20044.57.2.1.3.46.9 | Scalarrm10010e40AlmMsaHighPowerDown | read-only | current | Line Trscv High Power Down :This OID indicates the Line Trscv is entering Low Power state <Help> Status indicating the Line Trscv is entering Low Power state <… |
| 1.3.6.1.4.1.20044.57.2.1.3.47 | Noderm10010e40AlmmsaModuleGeneralStatus | |||
| 1.3.6.1.4.1.20044.57.2.1.3.47.4 | Scalarrm10010e40AlmMsaOutOfAlignment | read-only | current | Line Trscv Out Of Alignment :This OID indicates an Out of alignment on the Line Trscv Host Interface <Help> Alarm indicating an Out of alignment on the Line Tr… |
| 1.3.6.1.4.1.20044.57.2.1.3.47.5 | Scalarrm10010e40AlmMsaRxNetworkLol | read-only | current | Line Trscv Rx Network Loss Of Lock :This OID indicates of Loss of Lock is detected on the Line Trscv Rx Network interface <Help> Alarm indicating of Loss of Lo… |
| 1.3.6.1.4.1.20044.57.2.1.3.47.6 | Scalarrm10010e40AlmMsaRxLos | read-only | current | Line Trscv Loss Of Signal :This OID indicates a Loss of Signal is detected on the Line Trscv <Help> Alarm indicating a Loss of Signal is detected on the Line T… |
| 1.3.6.1.4.1.20044.57.2.1.3.47.7 | Scalarrm10010e40AlmMsaTxHostLol | read-only | current | Line Trscv Tx Host Loss Of Lock :This OID indicates of Loss of Lock is detected on the Line Trscv Tx Host interface <Help> Alarm indicating of Loss of Lock is … |
| 1.3.6.1.4.1.20044.57.2.1.3.47.8 | Scalarrm10010e40AlmMsaTxLosf | read-only | current | Line Trscv Loss Of Signal Functionality :This OID indicates a Loss of Signal functionality is detected on the Line Trscv <Help> Alarm indicating a Loss of Sign… |
| 1.3.6.1.4.1.20044.57.2.1.3.47.9 | Scalarrm10010e40AlmMsaTxCmuLol | read-only | current | Line Trscv CMU Loss Of Lock :This OID indicates a Clock Multiplier Unit Loss of Lock is detected on the Line Trscv <Help> Alarm indicating a Clock Multiplier U… |
| 1.3.6.1.4.1.20044.57.2.1.3.47.10 | Scalarrm10010e40AlmMsaTxJitterPllLol | read-only | current | Line Trscv Tx Jitter PLL Loss Of Lock :This OID indicates a Tx Jitter PLL Loss of Lock is detected on the Line Trscv <Help> Alarm indicating a Tx Jitter PLL Lo… |
| 1.3.6.1.4.1.20044.57.2.1.3.47.11 | Scalarrm10010e40AlmMsaLossOfRefclk | read-only | current | Line Trscv Loss Of Ref Clock :This OID indicates a Loss of Reference clock is detected on the Line Trscv <Help> Alarm indicating a Loss of Reference clock is d… |
| 1.3.6.1.4.1.20044.57.2.1.3.47.14 | Scalarrm10010e40AlmMsaHwInterlock | read-only | current | Line Trscv Hardware Interlock :This OID indicates the Line Trscv power is higher than the cooling capacity <Help> Alarm indicating the Line Trscv power is high… |
| 1.3.6.1.4.1.20044.57.2.1.3.48 | Noderm10010e40AlmmsaGlobalAlarmSummary | |||
| 1.3.6.1.4.1.20044.57.2.1.3.48.1 | Scalarrm10010e40AlmMsaSoftGlobAlarmTest | read-only | current | Line Trscv Global Alarm SW Test :This OID indicates the Line Trscv Global alarm This OID is raised by SW request for test purpose <Help> Status indicating the … |
| 1.3.6.1.4.1.20044.57.2.1.3.48.6 | Scalarrm10010e40AlmMsaNetworkHostAlarmStatus | read-only | current | Line Trscv Network/Host Alarm Status :This OID indicates the state of the Network and Host interface of the Line Trscv <Help> Synthesis alarm indicating the al… |
| 1.3.6.1.4.1.20044.57.2.1.3.48.7 | Scalarrm10010e40AlmMsaNetworkLaneAlarmWarning2 | read-only | current | Line Trscv Network Alarm And Warning 2 :This OID indicates at least one DDM This OID is detected on the Line Trscv Network Interface <Help> Synthesis alarm ind… |
| 1.3.6.1.4.1.20044.57.2.1.3.48.8 | Scalarrm10010e40AlmMsaModuleState | read-only | current | Line Trscv Module State :This OID indicates the Line Trscv module state <Help> Synthesis alarm indicating the Line Trscv module state <Condtype> MSA_MODULE_STA… |
| 1.3.6.1.4.1.20044.57.2.1.3.48.9 | Scalarrm10010e40AlmMsaModuleGeneralStatus | read-only | current | Line Trscv General Status :This OID indicates the Line Trscv module general <Help> Synthesis alarm indicating the Line Trscv module general status <Condtype> M… |
| 1.3.6.1.4.1.20044.57.2.1.3.48.10 | Scalarrm10010e40AlmModuleFault | read-only | current | Line Trscv Module Fault :This OID indicates at least one Fault is detected on the Line Trscv module <Help> Synthesis alarm indicating at least one Fault is det… |
| 1.3.6.1.4.1.20044.57.2.1.3.48.11 | Scalarrm10010e40AlmMsaModuleAlarmWarning1 | read-only | current | Line Trscv Module Alarm And Warning 1 :This OID indicates at least one DDM is detected on the Line Trscv module <Help> Synthesis alarm indicating at least one … |
| 1.3.6.1.4.1.20044.57.2.1.3.48.12 | Scalarrm10010e40AlmMsaModuleAlarmWarning2 | read-only | current | Line Trscv Module Alarm And Warning 2 :This OID indicates at least one DDM is detected on the Line Trscv module <Help> Synthesis alarm indicating at least one … |
| 1.3.6.1.4.1.20044.57.2.1.3.48.13 | Scalarrm10010e40AlmMsaNetworkLaneAlarmWarning1 | read-only | current | Line Trscv Network Alarm And Warning 1 :This OID indicates at least one DDM is detected on the Line Trscv Network Interface <Help> Synthesis alarm indicating a… |
| 1.3.6.1.4.1.20044.57.2.1.3.48.14 | Scalarrm10010e40AlmMsaNetworkLaneFaultStatus | read-only | current | Line Trscv Network Fault And Status :This OID indicates at least one Fault or Status is detected on the Line Trscv Network Interface <Help> Synthesis alarm ind… |
| 1.3.6.1.4.1.20044.57.2.1.3.48.15 | Scalarrm10010e40AlmMsaHostLaneFaultStatus | read-only | current | Line Trscv Host Fault And Status :This OID indicates at least one Fault or Status is detected on the Line Trscv Host Interface <Help> Synthesis alarm indicatin… |
| 1.3.6.1.4.1.20044.57.2.1.3.48.16 | Scalarrm10010e40AlmMsaGlobAlarmAssertion | read-only | current | Line Trscv Global Alarm :This OID indicates at least one Fault or Status is detected on the Line Trscv module <Help> Synthesis alarm indicating at least one Al… |
| 1.3.6.1.4.1.20044.57.2.1.3.49 | Noderm10010e40AlmmsaNetworkTxAlignment | |||
| 1.3.6.1.4.1.20044.57.2.1.3.49.12 | Scalarrm10010e40AlmNetTxTimingFault | read-only | current | Line Trscv Network Tx Timing Fault :This OID indicates a Tx Timing Fault is detected on the Line Trscv Network interface <Help> Alarm indicating a Tx Timing Fa… |
| 1.3.6.1.4.1.20044.57.2.1.3.49.13 | Scalarrm10010e40AlmNetTxReferenceClockFault | read-only | current | Line Trscv Network Tx Ref Clock Fault :This OID indicates a Tx Reference Clock Fault is detected on the Line Trscv Network interface <Help> Alarm indicating a … |
| 1.3.6.1.4.1.20044.57.2.1.3.49.14 | Scalarrm10010e40AlmNetTxCmuLockFault | read-only | current | Line Trscv Network Tx CMU Lock Fault :This OID indicates a Tx Clock Multiplier Unit Lock Fault is detected on the Line Trscv Network interface <Help> Alarm ind… |
| 1.3.6.1.4.1.20044.57.2.1.3.49.15 | Scalarrm10010e40AlmNetTxOutOfAlignment | read-only | current | Line Trscv Network Tx Out Of Alignment :This OID indicates a Tx Out of Alignment is detected on the Line Trscv Network interface <Help> Alarm indicating a Tx O… |
| 1.3.6.1.4.1.20044.57.2.1.3.49.16 | Scalarrm10010e40AlmNetTxLossOfAlignment | read-only | current | Line Trscv Network Tx Loss Of Alignment :This OID indicates a Tx Loss of Alignment is detected on the Line Trscv Network interface <Help> Alarm indicating a Tx… |
| 1.3.6.1.4.1.20044.57.2.1.3.50 | Noderm10010e40AlmmsaNetworkRxAlignment | |||
| 1.3.6.1.4.1.20044.57.2.1.3.50.12 | Scalarrm10010e40AlmNetRxTimingFault | read-only | current | Line Trscv Network Rx Timing Fault :This OID indicates a Rx Timing Fault is detected on the Line Trscv Network interface <Help> Alarm indicating a Rx Timing Fa… |
| 1.3.6.1.4.1.20044.57.2.1.3.50.13 | Scalarrm10010e40AlmNetRxOutOfAlignment | read-only | current | Line Trscv Network Rx Out Of Alignment :This OID indicates a Rx Out of Alignment is detected on the Line Trscv Network interface <Help> Alarm indicating a Rx O… |
| 1.3.6.1.4.1.20044.57.2.1.3.50.14 | Scalarrm10010e40AlmNetRxLossOfAlignment | read-only | current | Line Trscv Network Rx Loss Of Alignment :This OID indicates a Rx Loss of Alignment is detected on the Line Trscv Network interface <Help> Alarm indicating a Rx… |
| 1.3.6.1.4.1.20044.57.2.1.3.50.15 | Scalarrm10010e40AlmNetRxModemLockFault | read-only | current | Line Trscv Network Rx Modem Lock Fault :This OID indicates a Rx Modem Lock Fault is detected on the Line Trscv Network interface <Help> Alarm indicating a Rx M… |
| 1.3.6.1.4.1.20044.57.2.1.3.50.16 | Scalarrm10010e40AlmNetRxModemSyncDetectFault | read-only | current | Line Trscv Network Rx Modem Sync Detect Fault :This OID indicates a Rx Modem Synchronisation Detection Fault is detected on the Line Trscv Network interface <H… |
| 1.3.6.1.4.1.20044.57.2.1.3.51 | Noderm10010e40AlmmsaNetworkHostNetworkAlarmSummary | |||
| 1.3.6.1.4.1.20044.57.2.1.3.51.11 | Scalarrm10010e40AlmNetworkTxAlignment | read-only | current | Line Trscv Network Tx Alignment :This OID indicates a Tx Alignment Fault is detected on the Line Trscv Network interface <Help> Synthesis Alarm indicating a Tx… |
| 1.3.6.1.4.1.20044.57.2.1.3.51.12 | Scalarrm10010e40AlmNetworkRxAlignment | read-only | current | Line Trscv Network Rx Alignment :This OID indicates a Rx Alignment Fault is detected on the Line Trscv Network interface <Help> Synthesis Alarm indicating a Rx… |
| 1.3.6.1.4.1.20044.57.2.1.3.51.13 | Scalarrm10010e40AlmNetworkRxOtn | read-only | current | Line Trscv Network Rx OTN :This OID indicates a Rx OTN Fault is detected on the Line Trscv Network interface <Help> Synthesis Alarm indicating a Rx OTN Fault i… |
| 1.3.6.1.4.1.20044.57.2.1.3.51.14 | Scalarrm10010e40AlmHostRxAlignment | read-only | current | Line Trscv Host Rx Alignment :This OID indicates a Rx Alignment Fault is detected on the Line Trscv Host interface <Help> Synthesis Alarm indicating a Rx Align… |
| 1.3.6.1.4.1.20044.57.2.1.3.51.15 | Scalarrm10010e40AlmHostTxAlignment | read-only | current | Line Trscv Host Tx Alignment :This OID indicates a Tx Alignment Fault is detected on the Line Trscv Host interface <Help> Synthesis Alarm indicating a Tx Align… |
| 1.3.6.1.4.1.20044.57.2.1.3.51.16 | Scalarrm10010e40AlmHostTxOtnStatus | read-only | current | Line Trscv Host Tx OTN :This OID indicates a Tx OTN Fault is detected on the Line Trscv Host interface <Help> Synthesis Alarm indicating a Tx OTN Fault is dete… |
| 1.3.6.1.4.1.20044.57.2.1.3.52 | Noderm10010e40AlmmsaHostTxAlignment | |||
| 1.3.6.1.4.1.20044.57.2.1.3.52.13 | Scalarrm10010e40AlmHostTxDeskewLockFault | read-only | current | Line Trscv Host Tx Deskew Lock Fault :This OID indicates a Tx Deskew Lock Fault is detected on the Line Trscv Host interface <Help> Alarm indicating a Tx Deske… |
| 1.3.6.1.4.1.20044.57.2.1.3.52.14 | Scalarrm10010e40AlmHostTxOutOfAlignment | read-only | current | Line Trscv Host Tx Out Of Alignment :This OID indicates a Tx Out of Alignment is detected on the Line Trscv Host interface <Help> Alarm indicating a Tx Out of … |
| 1.3.6.1.4.1.20044.57.2.1.3.52.15 | Scalarrm10010e40AlmHostTxLossOfAlignment | read-only | current | Line Trscv Host Tx Loss Of Alignment :This OID indicates a Tx Loss of Alignment is detected on the Line Trscv Host interface <Help> Alarm indicating a Tx Loss … |
| 1.3.6.1.4.1.20044.57.2.1.3.52.16 | Scalarrm10010e40AlmHostTxCdrLockFault | read-only | current | Line Trscv Host Tx CDR Lock Fault :This OID indicates a Tx Clock Data Recovery Lock Fault is detected on the Line Trscv Host interface <Help> Alarm indicating … |
| 1.3.6.1.4.1.20044.57.2.1.3.53 | Noderm10010e40AlmmsaHostRxAlignment | |||
| 1.3.6.1.4.1.20044.57.2.1.3.53.14 | Scalarrm10010e40AlmHostRxCmuLockFault | read-only | current | Line Trscv Host Rx CMU Lock Fault :This OID indicates a Rx Clock Multiplier Unit Lock Fault is detected on the Line Trscv Host interface <Help> Alarm indicatin… |
| 1.3.6.1.4.1.20044.57.2.1.3.53.15 | Scalarrm10010e40AlmHostRxOutOfAlignment | read-only | current | Line Trscv Host Rx Out Of Alignment :This OID indicates a Rx Out of Alignment is detected on the Line Trscv Host interface <Help> Alarm indicating a Rx Out of … |
| 1.3.6.1.4.1.20044.57.2.1.3.53.16 | Scalarrm10010e40AlmHostRxLossOfAlignment | read-only | current | Line Trscv Host Rx Loss Of Alignment :This OID indicates a Rx Loss of Alignment is detected on the Line Trscv Host interface <Help> Alarm indicating a Rx Loss … |
| 1.3.6.1.4.1.20044.57.2.2 | Noderm10010e40AlmClient | |||
| 1.3.6.1.4.1.20044.57.2.2.1 | Noderm10010e40AlmClientNurg | |||
| 1.3.6.1.4.1.20044.57.2.2.1.56 | Tablerm10010e40AlmclientNetworkLaneAlarmWarningTable | not-accessible | current | List of rm10010e40AlmclientNetworkLaneAlarmWarning Article |
| 1.3.6.1.4.1.20044.57.2.2.1.56.1 | Rowrm10010e40AlmclientNetworkLaneAlarmWarningEntry | not-accessible | current | Row definition for the rm10010e40AlmclientNetworkLaneAlarmWarning table |
| 1.3.6.1.4.1.20044.57.2.2.1.56.1.1 | Columnrm10010e40AlmclientNetworkLaneAlarmWarningIndex | read-only | current | Index definition for the rm10010e40AlmclientNetworkLaneAlarmWarning table |
| 1.3.6.1.4.1.20044.57.2.2.1.56.1.2 | Columnrm10010e40AlmClientRxPowerLowAlarmPortn | read-only | current | Client Trscv Rx Power Low Alarm :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indic… |
| 1.3.6.1.4.1.20044.57.2.2.1.56.1.3 | Columnrm10010e40AlmClientRxPowerLowWarningPortn | read-only | current | Client Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning i… |
| 1.3.6.1.4.1.20044.57.2.2.1.56.1.4 | Columnrm10010e40AlmClientRxPowerHighWarningPortn | read-only | current | Client Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning… |
| 1.3.6.1.4.1.20044.57.2.2.1.56.1.5 | Columnrm10010e40AlmClientRxPowerHighAlarmPortn | read-only | current | Client Trscv Rx Power High Alarm :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm ind… |
| 1.3.6.1.4.1.20044.57.2.2.1.56.1.6 | Columnrm10010e40AlmLaserTempLowAlarmPortn | read-only | current | Client Trscv Laser Temp Low Alarm :This OID indicates that the Trscv Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help> Ala… |
| 1.3.6.1.4.1.20044.57.2.2.1.56.1.7 | Columnrm10010e40AlmClientLaserTempLowWarningPortn | read-only | current | Client Trscv Laser Temp Low Warning :This OID indicates that the Trscv Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help> W… |
| 1.3.6.1.4.1.20044.57.2.2.1.56.1.8 | Columnrm10010e40AlmClientLaserTempHighWarningPortn | read-only | current | Client Trscv Laser Temp High Warning :This OID indicates that the Trscv Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Help>… |
| 1.3.6.1.4.1.20044.57.2.2.1.56.1.9 | Columnrm10010e40AlmClientLaserTempHighAlarmPortn | read-only | current | Client Trscv Laser Temp High Alarm :This OID indicates that the Trscv Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Help> A… |
| 1.3.6.1.4.1.20044.57.2.2.1.56.1.10 | Columnrm10010e40AlmClientTxPowerLowAlarmPortn | read-only | current | Client Trscv Tx Power Low Alarm :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indi… |
| 1.3.6.1.4.1.20044.57.2.2.1.56.1.11 | Columnrm10010e40AlmClientTxPowerLowWarningPortn | read-only | current | Client Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning … |
| 1.3.6.1.4.1.20044.57.2.2.1.56.1.12 | Columnrm10010e40AlmClientTxPowerHighWarningPortn | read-only | current | Client Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warnin… |
| 1.3.6.1.4.1.20044.57.2.2.1.56.1.13 | Columnrm10010e40AlmClientTxPowerHighAlarmPortn | read-only | current | Client Trscv Tx Power High Alarm :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm in… |
| 1.3.6.1.4.1.20044.57.2.2.1.56.1.14 | Columnrm10010e40AlmClientBiasLowAlarmPortn | read-only | current | Client Trscv Bias Low Alarm :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in… |
| 1.3.6.1.4.1.20044.57.2.2.1.56.1.15 | Columnrm10010e40AlmClientBiasLowWarningPortn | read-only | current | Client Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warnin… |
| 1.3.6.1.4.1.20044.57.2.2.1.56.1.16 | Columnrm10010e40AlmClientBiasHighWarningPortn | read-only | current | Client Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warn… |
| 1.3.6.1.4.1.20044.57.2.2.1.56.1.17 | Columnrm10010e40AlmClientBiasHighAlarmPortn | read-only | current | Client Trscv Bias High Alarm :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Alarm … |
| 1.3.6.1.4.1.20044.57.2.2.1.232 | Tablerm10010e40AlmclientSfpWarnDdmTable | not-accessible | current | List of rm10010e40AlmclientSfpWarnDdm Article |
| 1.3.6.1.4.1.20044.57.2.2.1.232.1 | Rowrm10010e40AlmclientSfpWarnDdmEntry | not-accessible | current | Row definition for the rm10010e40AlmclientSfpWarnDdm table |
| 1.3.6.1.4.1.20044.57.2.2.1.232.1.1 | Columnrm10010e40AlmclientSfpWarnDdmIndex | read-only | current | Index definition for the rm10010e40AlmclientSfpWarnDdm table |
| 1.3.6.1.4.1.20044.57.2.2.1.232.1.2 | Columnrm10010e40AlmTxPwLowWngPortn | read-only | current | Client Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning … |
| 1.3.6.1.4.1.20044.57.2.2.1.232.1.3 | Columnrm10010e40AlmTxPwrHighWngPortn | read-only | current | Client Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warnin… |
| 1.3.6.1.4.1.20044.57.2.2.1.232.1.4 | Columnrm10010e40AlmTxBiasLowWngPortn | read-only | current | Client Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warnin… |
| 1.3.6.1.4.1.20044.57.2.2.1.232.1.5 | Columnrm10010e40AlmTxBiasHighWngPortn | read-only | current | Client Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warn… |
| 1.3.6.1.4.1.20044.57.2.2.1.232.1.6 | Columnrm10010e40AlmVccLowWngPortn | read-only | current | Client Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Warn… |
| 1.3.6.1.4.1.20044.57.2.2.1.232.1.7 | Columnrm10010e40AlmVccHighWngPortn | read-only | current | Client Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Wa… |
| 1.3.6.1.4.1.20044.57.2.2.1.232.1.8 | Columnrm10010e40AlmTempLowWngPortn | read-only | current | Client Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indic… |
| 1.3.6.1.4.1.20044.57.2.2.1.232.1.9 | Columnrm10010e40AlmTempHighWngPortn | read-only | current | Client Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning ind… |
| 1.3.6.1.4.1.20044.57.2.2.1.232.1.16 | Columnrm10010e40AlmRxPwrLowWngPortn | read-only | current | Client Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning i… |
| 1.3.6.1.4.1.20044.57.2.2.1.232.1.17 | Columnrm10010e40AlmRxPwrHighWngPortn | read-only | current | Client Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning… |
| 1.3.6.1.4.1.20044.57.2.2.2 | Noderm10010e40AlmClientUrg | |||
| 1.3.6.1.4.1.20044.57.2.2.2.72 | Tablerm10010e40AlmclientNetworkLaneFaultTable | not-accessible | current | List of rm10010e40AlmclientNetworkLaneFault Article |
| 1.3.6.1.4.1.20044.57.2.2.2.72.1 | Rowrm10010e40AlmclientNetworkLaneFaultEntry | not-accessible | current | Row definition for the rm10010e40AlmclientNetworkLaneFault table |
| 1.3.6.1.4.1.20044.57.2.2.2.72.1.1 | Columnrm10010e40AlmclientNetworkLaneFaultIndex | read-only | current | Index definition for the rm10010e40AlmclientNetworkLaneFault table |
| 1.3.6.1.4.1.20044.57.2.2.2.72.1.4 | Columnrm10010e40AlmClientLaneRxFifoErrorPortn | read-only | current | Client Network Lane Rx FIFO Error :This OID indicates a Rx FIFO Error on the Client Trscv Network Lane <Help> Alarm indicating a Rx FIFO Error on the Client Tr… |
| 1.3.6.1.4.1.20044.57.2.2.2.72.1.5 | Columnrm10010e40AlmClientLaneRxLolPortn | read-only | current | Client Network Lane Rx Loss Of Lock :This OID indicates a Rx Loss of Lock on the Client Trscv Network Lane <Help> Alarm indicating a Rx Loss of Lock on the Cli… |
| 1.3.6.1.4.1.20044.57.2.2.2.72.1.6 | Columnrm10010e40AlmClientLaneRxLosPortn | read-only | current | Client Network Lane Rx Loss Of Signal :This OID indicates a Rx Loss of Signal on the Client Trscv Network Lane <Help> Alarm indicating a Rx Loss of Signal on t… |
| 1.3.6.1.4.1.20044.57.2.2.2.72.1.8 | Columnrm10010e40AlmClientLaneTxLolPortn | read-only | current | Client Network Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Client Trscv Network Lane <Help> Alarm indicating a Tx Loss of Lock on the Cli… |
| 1.3.6.1.4.1.20044.57.2.2.2.72.1.9 | Columnrm10010e40AlmClientLaneTxLosfPortn | read-only | current | Client Network Lane Tx Loss Of Signal Functionality :This OID indicates a Tx Loss of Signal Functionality on the Client Trscv Network Lane <Help> Alarm indicat… |
| 1.3.6.1.4.1.20044.57.2.2.2.72.1.15 | Columnrm10010e40AlmClientLaneApdPowerSupplyPortn | read-only | current | Client Network Lane APD Power Supply :This OID indicates an APD Power supply failure on the Client Trscv Network Lane <Help> Alarm indicating an APD Power supp… |
| 1.3.6.1.4.1.20044.57.2.2.2.72.1.16 | Columnrm10010e40AlmClientLaneWavelengthUnlockedPortn | read-only | current | Client Network Lane Wavelength Unlock :This OID indicates a Wavelength unlock on the Client Trscv Network Lane <Help> Alarm indicating a Wavelength unlock on t… |
| 1.3.6.1.4.1.20044.57.2.2.2.72.1.17 | Columnrm10010e40AlmClientLaneTecFaultPortn | read-only | current | Client Network Lane TEC Fault :This OID indicates a TEC Fault on the Client Trscv Network Lane <Help> Alarm indicating a TEC Fault on the Client Trscv Network … |
| 1.3.6.1.4.1.20044.57.2.2.2.88 | Tablerm10010e40AlmclientHostLaneFaultTable | not-accessible | current | List of rm10010e40AlmclientHostLaneFault Article |
| 1.3.6.1.4.1.20044.57.2.2.2.88.1 | Rowrm10010e40AlmclientHostLaneFaultEntry | not-accessible | current | Row definition for the rm10010e40AlmclientHostLaneFault table |
| 1.3.6.1.4.1.20044.57.2.2.2.88.1.1 | Columnrm10010e40AlmclientHostLaneFaultIndex | read-only | current | Index definition for the rm10010e40AlmclientHostLaneFault table |
| 1.3.6.1.4.1.20044.57.2.2.2.88.1.2 | Columnrm10010e40AlmClientLossOfSyncPortn | read-only | current | Client Frame Alignment Loss :This OID indicates the module is not aligned with the incoming Client signal <Help> Alarm indicating the module is not aligned wit… |
| 1.3.6.1.4.1.20044.57.2.2.2.88.1.3 | Columnrm10010e40AlmClientInputLossOfSigPortn | read-only | current | Client Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Client Trscv <Help> Alarm indicating a Loss of Signal is detected on the Cl… |
| 1.3.6.1.4.1.20044.57.2.2.2.88.1.4 | Columnrm10010e40AlmClientLanesMarkerUnlockPortn | read-only | current | Client Lanes Marker Unlock :This OID indicates the Client lanes marker alignment is not lock <Help> Alarm indicating the Client lanes marker alignment is not l… |
| 1.3.6.1.4.1.20044.57.2.2.2.88.1.5 | Columnrm10010e40AlmClientLanes6466UnlockPortn | read-only | current | Client Lanes 64/66b Unlock :This OID indicates the Client 64/66b decoder is not lock <Help> Alarm indicating the Client 64/66b decoder is not lock <Condtype> C… |
| 1.3.6.1.4.1.20044.57.2.2.2.88.1.6 | Columnrm10010e40AlmClientLanesNotAlignedPortn | read-only | current | Client Lanes Not Aligned :This OID indicates the Client lanes are not aligned <Help> Alarm indicating the Client lanes are not aligned <Condtype> CLIENT_LANES_… |
| 1.3.6.1.4.1.20044.57.2.2.2.88.1.7 | Columnrm10010e40AlmClientCsfDetectedPortn | read-only | current | Client Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client… |
| 1.3.6.1.4.1.20044.57.2.2.2.88.1.10 | Columnrm10010e40AlmClientTxHostLolPortn | read-only | current | Client Host Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Client Trscv Host Lane <Help> Alarm indicating a Tx Loss of Lock on the Client Tr… |
| 1.3.6.1.4.1.20044.57.2.2.2.88.1.11 | Columnrm10010e40AlmClientLaneTxFifoErrorPortn | read-only | current | Client Host Lane Tx FIFO Error :This OID indicates a Tx FIFO Error on the Client Trscv Host Lane <Help> Alarm indicating a Tx FIFO Error on the Client Trscv Ho… |
| 1.3.6.1.4.1.20044.57.2.2.2.216 | Tablerm10010e40AlmclientSfpAlmDdmTable | not-accessible | current | List of rm10010e40AlmclientSfpAlmDdm Article |
| 1.3.6.1.4.1.20044.57.2.2.2.216.1 | Rowrm10010e40AlmclientSfpAlmDdmEntry | not-accessible | current | Row definition for the rm10010e40AlmclientSfpAlmDdm table |
| 1.3.6.1.4.1.20044.57.2.2.2.216.1.1 | Columnrm10010e40AlmclientSfpAlmDdmIndex | read-only | current | Index definition for the rm10010e40AlmclientSfpAlmDdm table |
| 1.3.6.1.4.1.20044.57.2.2.2.216.1.2 | Columnrm10010e40AlmTxPwrLowAlaPortn | read-only | current | Client Trscv Tx Power Low :This OID indicates that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in… |
| 1.3.6.1.4.1.20044.57.2.2.2.216.1.3 | Columnrm10010e40AlmTxPwrHighAlaPortn | read-only | current | Client Trscv Tx Power High :This OID indicates that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm … |
| 1.3.6.1.4.1.20044.57.2.2.2.216.1.4 | Columnrm10010e40AlmTxBiasLowAlaPortn | read-only | current | Client Trscv Bias Low :This OID indicates that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm … |
| 1.3.6.1.4.1.20044.57.2.2.2.216.1.5 | Columnrm10010e40AlmTxBiasHighAlaPortn | read-only | current | Client Trscv Bias High :This OID indicates that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM <Help> Alar… |
| 1.3.6.1.4.1.20044.57.2.2.2.216.1.6 | Columnrm10010e40AlmVccLowAlaPortn | read-only | current | Client Trscv Power Supply Low :This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM <Help> Alar… |
| 1.3.6.1.4.1.20044.57.2.2.2.216.1.7 | Columnrm10010e40AlmVccHighAlaPortn | read-only | current | Client Trscv Power Supply High :This OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM <Help> Al… |
| 1.3.6.1.4.1.20044.57.2.2.2.216.1.8 | Columnrm10010e40AlmTempLowAlaPortn | read-only | current | Client Trscv Temp Low :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicat… |
| 1.3.6.1.4.1.20044.57.2.2.2.216.1.9 | Columnrm10010e40AlmTempHighAlaPortn | read-only | current | Client Trscv Temp High :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indic… |
| 1.3.6.1.4.1.20044.57.2.2.2.216.1.16 | Columnrm10010e40AlmRxPwrLowAlaPortn | read-only | current | Client Trscv Rx Power Low :This OID indicates that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm ind… |
| 1.3.6.1.4.1.20044.57.2.2.2.216.1.17 | Columnrm10010e40AlmRxPwrHighAlaPortn | read-only | current | Client Trscv Rx Power High :This OID indicates that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm i… |
| 1.3.6.1.4.1.20044.57.2.2.3 | Noderm10010e40AlmClientCrit | |||
| 1.3.6.1.4.1.20044.57.2.2.3.8 | Tablerm10010e40AlmsynthAlmPortTable | not-accessible | current | List of rm10010e40AlmsynthAlmPort Article |
| 1.3.6.1.4.1.20044.57.2.2.3.8.1 | Rowrm10010e40AlmsynthAlmPortEntry | not-accessible | current | Row definition for the rm10010e40AlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.57.2.2.3.8.1.1 | Columnrm10010e40AlmsynthAlmPortIndex | read-only | current | Index definition for the rm10010e40AlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.57.2.2.3.8.1.2 | Columnrm10010e40AlmSfpAbsentPortn | read-only | current | Client Optical Module Absent :This OID indicates that the Transceiver is not present in the client port. <Help> This alarm indicates if the client transceiver … |
| 1.3.6.1.4.1.20044.57.2.2.3.8.1.3 | Columnrm10010e40AlmDdmAbsentPortn | read-only | current | DDM Supported On Client Trscv :This OID indicates that the Client transceiver supports the Digital Diagnostic Monitoring function <Help> This status indicates … |
| 1.3.6.1.4.1.20044.57.2.2.3.8.1.5 | Columnrm10010e40AlmHwFailAccPortn | read-only | current | Client HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Help> This alarm indicates a failure on client port, most pro… |
| 1.3.6.1.4.1.20044.57.2.2.3.8.1.6 | Columnrm10010e40AlmDwLsdPortn | read-only | current | Client Trscv Laser Shutdown :This OID indicates the Client transceiver laser is shutdown <Help> This status indicates if the client transceiver laser is shutdo… |
| 1.3.6.1.4.1.20044.57.2.2.3.8.1.7 | Columnrm10010e40AlmClientLocalOosPortn | read-only | current | Local Client Port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local c… |
| 1.3.6.1.4.1.20044.57.2.2.3.8.1.8 | Columnrm10010e40AlmClientRemoteOosPortn | read-only | current | Remote Client Port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the remot… |
| 1.3.6.1.4.1.20044.57.2.2.3.8.1.9 | Columnrm10010e40AlmDwCaisPortn | read-only | current | Client AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indicates if a Client Alarm Indication Signal is… |
| 1.3.6.1.4.1.20044.57.2.2.3.8.1.10 | Columnrm10010e40AlmSfpDdmWarningPortn | read-only | current | Warning On Client Trscv DDM :This OID indicates a warning is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Warning has be… |
| 1.3.6.1.4.1.20044.57.2.2.3.8.1.11 | Columnrm10010e40AlmSfpDdmAlmPortn | read-only | current | Alarm On Client Trscv DDM :This OID indicates an alarm is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Alarm has been de… |
| 1.3.6.1.4.1.20044.57.2.2.3.8.1.13 | Columnrm10010e40AlmFailAccPortn | read-only | current | Client Access Fail :This OID indicates a failure on the Client port <Help> This alarm indicates a failure on the Client port <Condtype> FAIL_ACC_1 <Probcause> … |
| 1.3.6.1.4.1.20044.57.2.2.3.8.1.17 | Columnrm10010e40AlmUpCsfPortn | read-only | current | Client Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu… |
| 1.3.6.1.4.1.20044.57.2.3 | Noderm10010e40AlmLine | |||
| 1.3.6.1.4.1.20044.57.2.3.1 | Noderm10010e40AlmLineNurg | |||
| 1.3.6.1.4.1.20044.57.2.3.1.104 | Tablerm10010e40AlmlineNetworkLaneAlarmWarning1Table | not-accessible | current | List of rm10010e40AlmlineNetworkLaneAlarmWarning1 Article |
| 1.3.6.1.4.1.20044.57.2.3.1.104.1 | Rowrm10010e40AlmlineNetworkLaneAlarmWarning1Entry | not-accessible | current | Row definition for the rm10010e40AlmlineNetworkLaneAlarmWarning1 table |
| 1.3.6.1.4.1.20044.57.2.3.1.104.1.1 | Columnrm10010e40AlmlineNetworkLaneAlarmWarning1Index | read-only | current | Index definition for the rm10010e40AlmlineNetworkLaneAlarmWarning1 table |
| 1.3.6.1.4.1.20044.57.2.3.1.104.1.2 | Columnrm10010e40AlmLineRxPowerLowAlarmPortn | read-only | current | Line Trscv Rx Power Low Alarm :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicat… |
| 1.3.6.1.4.1.20044.57.2.3.1.104.1.3 | Columnrm10010e40AlmLineRxPowerLowWarningPortn | read-only | current | Line Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning ind… |
| 1.3.6.1.4.1.20044.57.2.3.1.104.1.4 | Columnrm10010e40AlmLineRxPowerHighWarningPortn | read-only | current | Line Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning i… |
| 1.3.6.1.4.1.20044.57.2.3.1.104.1.5 | Columnrm10010e40AlmLineRxPowerHighAlarmPortn | read-only | current | Line Trscv Rx Power High Alarm :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indic… |
| 1.3.6.1.4.1.20044.57.2.3.1.104.1.6 | Columnrm10010e40AlmLineLaserTempLowAlarmPortn | read-only | current | Line Trscv Tx Laser Temp Low Alarm :This OID indicates that the Trscv Tx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help>… |
| 1.3.6.1.4.1.20044.57.2.3.1.104.1.7 | Columnrm10010e40AlmLineLaserTempLowWarningPortn | read-only | current | Line Trscv Tx Laser Temp Low Warning :This OID indicates that the Trscv Tx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Hel… |
| 1.3.6.1.4.1.20044.57.2.3.1.104.1.8 | Columnrm10010e40AlmLineLaserTempHighWarningPortn | read-only | current | Line Trscv Tx Laser Temp High Warning :This OID indicates that the Trscv Tx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <H… |
| 1.3.6.1.4.1.20044.57.2.3.1.104.1.9 | Columnrm10010e40AlmLineLaserTempHighAlarmPortn | read-only | current | Line Trscv Tx Laser Temp High Alarm :This OID indicates that the Trscv Tx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Hel… |
| 1.3.6.1.4.1.20044.57.2.3.1.104.1.10 | Columnrm10010e40AlmLineTxPowerLowAlarmPortn | read-only | current | Line Trscv Tx Power Low Alarm :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indica… |
| 1.3.6.1.4.1.20044.57.2.3.1.104.1.11 | Columnrm10010e40AlmLineTxPowerLowWarningPortn | read-only | current | Line Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning in… |
| 1.3.6.1.4.1.20044.57.2.3.1.104.1.12 | Columnrm10010e40AlmLineTxPowerHighWarningPortn | read-only | current | Line Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warning … |
| 1.3.6.1.4.1.20044.57.2.3.1.104.1.13 | Columnrm10010e40AlmLineTxPowerHighAlarmPortn | read-only | current | Line Trscv Tx Power High Alarm :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indi… |
| 1.3.6.1.4.1.20044.57.2.3.1.104.1.14 | Columnrm10010e40AlmLineBiasLowAlarmPortn | read-only | current | Line Trscv Tx Bias Low Alarm :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alarm i… |
| 1.3.6.1.4.1.20044.57.2.3.1.104.1.15 | Columnrm10010e40AlmLineBiasLowWarningPortn | read-only | current | Line Trscv Tx Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warni… |
| 1.3.6.1.4.1.20044.57.2.3.1.104.1.16 | Columnrm10010e40AlmLineBiasHighWarningPortn | read-only | current | Line Trscv Tx Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> War… |
| 1.3.6.1.4.1.20044.57.2.3.1.104.1.17 | Columnrm10010e40AlmLineBiasHighAlarmPortn | read-only | current | Line Trscv Tx Bias High Alarm :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Alarm… |
| 1.3.6.1.4.1.20044.57.2.3.1.120 | Tablerm10010e40AlmlineNetworkLaneAlarmWarning2Table | not-accessible | current | List of rm10010e40AlmlineNetworkLaneAlarmWarning2 Article |
| 1.3.6.1.4.1.20044.57.2.3.1.120.1 | Rowrm10010e40AlmlineNetworkLaneAlarmWarning2Entry | not-accessible | current | Row definition for the rm10010e40AlmlineNetworkLaneAlarmWarning2 table |
| 1.3.6.1.4.1.20044.57.2.3.1.120.1.1 | Columnrm10010e40AlmlineNetworkLaneAlarmWarning2Index | read-only | current | Index definition for the rm10010e40AlmlineNetworkLaneAlarmWarning2 table |
| 1.3.6.1.4.1.20044.57.2.3.1.120.1.2 | Columnrm10010e40AlmTxModulatorBiasLowAlarmPortn | read-only | current | Line Trscv Tx Modulator Bias Low Alarm :This OID indicates that the Trscv Tx modulator bias current is lower than the threshold value written in the Trscv EEPR… |
| 1.3.6.1.4.1.20044.57.2.3.1.120.1.3 | Columnrm10010e40AlmTxModulatorBiasLowWarningPortn | read-only | current | Line Trscv Tx Modulator Bias Low Warning :This OID indicates that the Trscv Tx modulator bias current is lower than the threshold value written in the Trscv EE… |
| 1.3.6.1.4.1.20044.57.2.3.1.120.1.4 | Columnrm10010e40AlmTxModulatorBiasHighWarningPortn | read-only | current | Line Trscv Tx Modulator Bias High Warning :This OID indicates that the Trscv Tx modulator bias current is higher than the threshold value written in the Trscv … |
| 1.3.6.1.4.1.20044.57.2.3.1.120.1.5 | Columnrm10010e40AlmTxModulatorBiasHighAlarmPortn | read-only | current | Line Trscv Tx Modulator Bias High Alarm :This OID indicates that the Trscv Tx modulator bias current is higher than the threshold value written in the Trscv EE… |
| 1.3.6.1.4.1.20044.57.2.3.1.120.1.6 | Columnrm10010e40AlmRxLaserTempLowAlarmPortn | read-only | current | Line Trscv Rx Laser Temp Low Alarm :This OID indicates that the Trscv Rx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help>… |
| 1.3.6.1.4.1.20044.57.2.3.1.120.1.7 | Columnrm10010e40AlmRxLaserTempLowWarningPortn | read-only | current | Line Trscv Rx Laser Temp Low Warning :This OID indicates that the Trscv Rx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Hel… |
| 1.3.6.1.4.1.20044.57.2.3.1.120.1.8 | Columnrm10010e40AlmRxLaserTempHighWarningPortn | read-only | current | Line Trscv Rx Laser Temp High Warning :This OID indicates that the Trscv Rx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <H… |
| 1.3.6.1.4.1.20044.57.2.3.1.120.1.9 | Columnrm10010e40AlmRxLaserTempHighAlarmPortn | read-only | current | Line Trscv Rx Laser Temp High Alarm :This OID indicates that the Trscv Rx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Hel… |
| 1.3.6.1.4.1.20044.57.2.3.1.120.1.10 | Columnrm10010e40AlmRxLaserOutputLowAlarmPortn | read-only | current | Line Trscv Rx Output Power Low Alarm :This OID indicates that the Trscv Rx output power is lower than the threshold value written in the Trscv EEPROM <Help> Al… |
| 1.3.6.1.4.1.20044.57.2.3.1.120.1.11 | Columnrm10010e40AlmRxLaserOutputLowWarningPortn | read-only | current | Line Trscv Rx Output Power Low Warning :This OID indicates that the Trscv Rx output power is lower than the threshold value written in the Trscv EEPROM <Help> … |
| 1.3.6.1.4.1.20044.57.2.3.1.120.1.12 | Columnrm10010e40AlmRxLaserOutputHighWarningPortn | read-only | current | Line Trscv Rx Output Power High Warning :This OID indicates that the Trscv Rx output power is higher than the threshold value written in the Trscv EEPROM <Help… |
| 1.3.6.1.4.1.20044.57.2.3.1.120.1.13 | Columnrm10010e40AlmRxLaserOutputHighAlarmPortn | read-only | current | Line Trscv Rx Output Power High Alarm :This OID indicates that the Trscv Rx output power is higher than the threshold value written in the Trscv EEPROM <Help> … |
| 1.3.6.1.4.1.20044.57.2.3.1.120.1.14 | Columnrm10010e40AlmRxLaserBiasLowAlarmPortn | read-only | current | Line Trscv Rx Bias Low Alarm :This OID indicates that the Trscv Rx laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alar… |
| 1.3.6.1.4.1.20044.57.2.3.1.120.1.15 | Columnrm10010e40AlmRxLaserBiasLowWarningPortn | read-only | current | Line Trscv Rx Bias Low Warning :This OID indicates that the Trscv Rx laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Wa… |
| 1.3.6.1.4.1.20044.57.2.3.1.120.1.16 | Columnrm10010e40AlmRxLaserBiasHighWarningPortn | read-only | current | Line Trscv Rx Bias High Warning :This OID indicates that the Trscv Rx laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> … |
| 1.3.6.1.4.1.20044.57.2.3.1.120.1.17 | Columnrm10010e40AlmRxLaserBiasHighAlarmPortn | read-only | current | Line Trscv Rx Bias High Alarm :This OID indicates that the Trscv Rx laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Al… |
| 1.3.6.1.4.1.20044.57.2.3.2 | Noderm10010e40AlmLineUrg | |||
| 1.3.6.1.4.1.20044.57.2.3.2.136 | Tablerm10010e40AlmlineNetworkLaneFaultTable | not-accessible | current | List of rm10010e40AlmlineNetworkLaneFault Article |
| 1.3.6.1.4.1.20044.57.2.3.2.136.1 | Rowrm10010e40AlmlineNetworkLaneFaultEntry | not-accessible | current | Row definition for the rm10010e40AlmlineNetworkLaneFault table |
| 1.3.6.1.4.1.20044.57.2.3.2.136.1.1 | Columnrm10010e40AlmlineNetworkLaneFaultIndex | read-only | current | Index definition for the rm10010e40AlmlineNetworkLaneFault table |
| 1.3.6.1.4.1.20044.57.2.3.2.136.1.3 | Columnrm10010e40AlmLineLaneRxTecFaultPortn | read-only | current | Line Network Lane Rx TEC Fault :This OID indicates a Rx TEC Fault on the Line Trscv Network Lane <Help> Alarm indicating a Rx TEC Fault on the Line Trscv Netwo… |
| 1.3.6.1.4.1.20044.57.2.3.2.136.1.4 | Columnrm10010e40AlmLineLaneRxFifoErrorPortn | read-only | current | Line Network Lane Rx FIFO Error :This OID indicates a Rx FIFO Error on the Line Trscv Network Lane <Help> Alarm indicating a Rx FIFO Error on the Line Trscv Ne… |
| 1.3.6.1.4.1.20044.57.2.3.2.136.1.5 | Columnrm10010e40AlmLineLaneRxLolPortn | read-only | current | Line Network Lane Rx Loss Of Lock :This OID indicates a Rx Loss of Lock on the Line Trscv Network Lane <Help> Alarm indicating a Rx Loss of Lock on the Line Tr… |
| 1.3.6.1.4.1.20044.57.2.3.2.136.1.6 | Columnrm10010e40AlmLineLaneRxLosPortn | read-only | current | Line Network Lane Rx Loss Of Signal :This OID indicates a Rx Loss of Signal on the Line Trscv Network Lane <Help> Alarm indicating a Rx Loss of Signal on the L… |
| 1.3.6.1.4.1.20044.57.2.3.2.136.1.8 | Columnrm10010e40AlmLineLaneTxLolPortn | read-only | current | Line Network Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Line Trscv Network Lane <Help> Alarm indicating a Tx Loss of Lock on the Line Tr… |
| 1.3.6.1.4.1.20044.57.2.3.2.136.1.9 | Columnrm10010e40AlmLineLaneTxLosfPortn | read-only | current | Line Network Lane Tx Loss Of Signal Functionality :This OID indicates a Tx Loss of Signal Functionality on the Line Trscv Network Lane <Help> Alarm indicating … |
| 1.3.6.1.4.1.20044.57.2.3.2.136.1.15 | Columnrm10010e40AlmLineLaneApdPowerSupplyPortn | read-only | current | Line Network Lane APD Power Supply :This OID indicates an APD Power supply failure on the Line Trscv Network Lane <Help> Alarm indicating an APD Power supply f… |
| 1.3.6.1.4.1.20044.57.2.3.2.136.1.16 | Columnrm10010e40AlmLineLaneWavelengthUnlockedPortn | read-only | current | Line Network Lane Wavelength Unlock :This OID indicates a Wavelength unlock on the Line Trscv Network Lane <Help> Alarm indicating a Wavelength unlock on the L… |
| 1.3.6.1.4.1.20044.57.2.3.2.136.1.17 | Columnrm10010e40AlmLineLaneTecFaultPortn | read-only | current | Line Network Lane TEC Fault :This OID indicates a Tx TEC Fault on the Line Trscv Network Lane <Help> Alarm indicating a Tx TEC Fault on the Line Trscv Network … |
| 1.3.6.1.4.1.20044.57.2.3.2.152 | Tablerm10010e40AlmlineHostLaneFaultTable | not-accessible | current | List of rm10010e40AlmlineHostLaneFault Article |
| 1.3.6.1.4.1.20044.57.2.3.2.152.1 | Rowrm10010e40AlmlineHostLaneFaultEntry | not-accessible | current | Row definition for the rm10010e40AlmlineHostLaneFault table |
| 1.3.6.1.4.1.20044.57.2.3.2.152.1.1 | Columnrm10010e40AlmlineHostLaneFaultIndex | read-only | current | Index definition for the rm10010e40AlmlineHostLaneFault table |
| 1.3.6.1.4.1.20044.57.2.3.2.152.1.2 | Columnrm10010e40AlmLineInputLossOfSignalPortn | read-only | current | Line Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Line Trscv <Help> Alarm indicating a Loss of Signal is detected on the Line T… |
| 1.3.6.1.4.1.20044.57.2.3.2.152.1.3 | Columnrm10010e40AlmLineLossOfFramePortn | read-only | current | Line Loss Of Frame :This OID indicates the module is not aligned with the incoming Line signal <Help> Alarm indicating the module is not aligned with the incom… |
| 1.3.6.1.4.1.20044.57.2.3.2.152.1.4 | Columnrm10010e40AlmLineSmBdiInsertedPortn | read-only | current | Line SM BDI Inserted :This OID indicates a SM Backward Defect Indication is inserted on the outgoing Line signal <Help> Status indicating a SM Backward Defect … |
| 1.3.6.1.4.1.20044.57.2.3.2.152.1.5 | Columnrm10010e40AlmLineSmBdiDetectedPortn | read-only | current | Line SM BDI Detected :This OID indicates a SM Backward Defect Indication is detected on the incoming Line signal <Help> Alarm indicating a SM Backward Defect I… |
| 1.3.6.1.4.1.20044.57.2.3.2.152.1.6 | Columnrm10010e40AlmLineSmIaeInsertedPortn | read-only | current | Line SM IAE Inserted :This OID indicates a SM Incoming Alignment Error is inserted on the outgoing Line signal <Help> Status indicating a SM Incoming Alignment… |
| 1.3.6.1.4.1.20044.57.2.3.2.152.1.7 | Columnrm10010e40AlmLineSmIaeDetectedPortn | read-only | current | Line SM IAE Detected :This OID indicates a SM Incoming Alignment Error is detected on the incoming Line signal <Help> Alarm indicating a SM Incoming Alignment … |
| 1.3.6.1.4.1.20044.57.2.3.2.152.1.10 | Columnrm10010e40AlmLineTxHostLolPortn | read-only | current | Line Host Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Line Trscv Host Lane <Help> Alarm indicating a Tx Loss of Lock on the Line Trscv Ho… |
| 1.3.6.1.4.1.20044.57.2.3.2.152.1.11 | Columnrm10010e40AlmLineLaneTxFifoErrorPortn | read-only | current | Line Host Lane Tx FIFO Error :This OID indicates a Tx FIFO Error on the Line Trscv Host Lane <Help> Alarm indicating a Tx FIFO Error on the Line Trscv Host Lan… |
| 1.3.6.1.4.1.20044.57.2.3.2.168 | Tablerm10010e40AlmlineNetworkLaneRxOtnTable | not-accessible | current | List of rm10010e40AlmlineNetworkLaneRxOtn Article |
| 1.3.6.1.4.1.20044.57.2.3.2.168.1 | Rowrm10010e40AlmlineNetworkLaneRxOtnEntry | not-accessible | current | Row definition for the rm10010e40AlmlineNetworkLaneRxOtn table |
| 1.3.6.1.4.1.20044.57.2.3.2.168.1.1 | Columnrm10010e40AlmlineNetworkLaneRxOtnIndex | read-only | current | Index definition for the rm10010e40AlmlineNetworkLaneRxOtn table |
| 1.3.6.1.4.1.20044.57.2.3.2.168.1.10 | Columnrm10010e40AlmLineRxOtnOduAisPortn | read-only | current | Line Network Rx ODU AIS :This OID indicates an ODU This OID Indication Signal is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating… |
| 1.3.6.1.4.1.20044.57.2.3.2.168.1.11 | Columnrm10010e40AlmLineRxOtnOtuAisPortn | read-only | current | Line Network Rx OTU AIS :This OID indicates an OTU This OID Indication Signal is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating… |
| 1.3.6.1.4.1.20044.57.2.3.2.168.1.12 | Columnrm10010e40AlmLineRxSmBdiPortn | read-only | current | Line Network Rx SM BDI :This OID indicates an SM Backward Defect Indication is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating a… |
| 1.3.6.1.4.1.20044.57.2.3.2.168.1.13 | Columnrm10010e40AlmLineRxOtnIaePortn | read-only | current | Line Network Rx IAE :This OID indicates an Incoming Alignment Error is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating an Incomi… |
| 1.3.6.1.4.1.20044.57.2.3.2.168.1.14 | Columnrm10010e40AlmLineRxOtnOomPortn | read-only | current | Line Network Rx OOM :This OID indicates an Out of Multiframe is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating an Out of Multif… |
| 1.3.6.1.4.1.20044.57.2.3.2.168.1.15 | Columnrm10010e40AlmLineRxOtnLomPortn | read-only | current | Line Network Rx LOM :This OID indicates a Loss of Multiframe is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating a Loss of Multif… |
| 1.3.6.1.4.1.20044.57.2.3.2.168.1.16 | Columnrm10010e40AlmLineRxOtnOofPortn | read-only | current | Line Network Rx OOF :This OID indicates an Out of Frame is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating an Out of Frame is de… |
| 1.3.6.1.4.1.20044.57.2.3.2.168.1.17 | Columnrm10010e40AlmLineRxOtnLofPortn | read-only | current | Line Network Rx LOF :This OID indicates a Loss of Frame is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating a Loss of Frame is de… |
| 1.3.6.1.4.1.20044.57.2.3.2.184 | Tablerm10010e40AlmlineHostLaneTxOtnTable | not-accessible | current | List of rm10010e40AlmlineHostLaneTxOtn Article |
| 1.3.6.1.4.1.20044.57.2.3.2.184.1 | Rowrm10010e40AlmlineHostLaneTxOtnEntry | not-accessible | current | Row definition for the rm10010e40AlmlineHostLaneTxOtn table |
| 1.3.6.1.4.1.20044.57.2.3.2.184.1.1 | Columnrm10010e40AlmlineHostLaneTxOtnIndex | read-only | current | Index definition for the rm10010e40AlmlineHostLaneTxOtn table |
| 1.3.6.1.4.1.20044.57.2.3.2.184.1.10 | Columnrm10010e40AlmLineTxOtnOduAisPortn | read-only | current | Line Host Tx ODU AIS :This OID indicates an ODU This OID Indication Signal is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an OD… |
| 1.3.6.1.4.1.20044.57.2.3.2.184.1.11 | Columnrm10010e40AlmLineTxOtnOtuAisPortn | read-only | current | Line Host Tx OTU AIS :This OID indicates an OTU This OID Indication Signal is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an OT… |
| 1.3.6.1.4.1.20044.57.2.3.2.184.1.12 | Columnrm10010e40AlmLineTxSmBdiPortn | read-only | current | Line Host Tx SM BDI :This OID indicates an SM Backward Defect Indication is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an SM B… |
| 1.3.6.1.4.1.20044.57.2.3.2.184.1.13 | Columnrm10010e40AlmLineTxOtnIaePortn | read-only | current | Line Host Tx IAE :This OID indicates an Incoming Alignment Error is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an Incoming Ali… |
| 1.3.6.1.4.1.20044.57.2.3.2.184.1.14 | Columnrm10010e40AlmLineTxOtnOomPortn | read-only | current | Line Host Tx OOM :This OID indicates an Out of Multiframe is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an Out of Multiframe i… |
| 1.3.6.1.4.1.20044.57.2.3.2.184.1.15 | Columnrm10010e40AlmLineTxOtnLomPortn | read-only | current | Line Host Tx LOM :This OID indicates a Loss of Multiframe is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating a Loss of Multiframe i… |
| 1.3.6.1.4.1.20044.57.2.3.2.184.1.16 | Columnrm10010e40AlmLineTxOtnOofPortn | read-only | current | Line Host Tx OOF :This OID indicates an Out of Frame is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an Out of Frame is detected… |
| 1.3.6.1.4.1.20044.57.2.3.2.184.1.17 | Columnrm10010e40AlmLineTxOtnLofPortn | read-only | current | Line Host Tx LOF :This OID indicates a Loss of Frame is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating a Loss of Frame is detected… |
| 1.3.6.1.4.1.20044.57.2.3.3 | Noderm10010e40AlmLineCrit | |||
| 1.3.6.1.4.1.20044.57.2.3.3.24 | Tablerm10010e40AlmsynthAlmLineTable | not-accessible | current | List of rm10010e40AlmsynthAlmLine Article |
| 1.3.6.1.4.1.20044.57.2.3.3.24.1 | Rowrm10010e40AlmsynthAlmLineEntry | not-accessible | current | Row definition for the rm10010e40AlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.57.2.3.3.24.1.1 | Columnrm10010e40AlmsynthAlmLineIndex | read-only | current | Index definition for the rm10010e40AlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.57.2.3.3.24.1.2 | Columnrm10010e40AlmXfpAbsentPortn | read-only | current | Line Optical Module Absent :This OID indicates that the line optical interface is not present. <Help> This alarm indicates if the line transceiver is not plugg… |
| 1.3.6.1.4.1.20044.57.2.3.3.24.1.3 | Columnrm10010e40AlmXfpInitNotComplPortn | read-only | current | Line Optical Module Ready :This OID indicates that the optical interface is not operational. <Help> This status indicates if the line transceiver has been corr… |
| 1.3.6.1.4.1.20044.57.2.3.3.24.1.5 | Columnrm10010e40AlmLineHwFailPortn | read-only | current | Line Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Help> This alarm indicates a failure on line port, most pr… |
| 1.3.6.1.4.1.20044.57.2.3.3.24.1.6 | Columnrm10010e40AlmXfpTxOffPortn | read-only | current | Line Trscv Laser Shutdown :This OID indicates the Line transceiver laser is shutdown <Help> This status indicates if the Line transceiver laser is shutdown <Co… |
| 1.3.6.1.4.1.20044.57.2.3.3.24.1.7 | Columnrm10010e40AlmLineLocalOosPortn | read-only | current | Line Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service… |
| 1.3.6.1.4.1.20044.57.2.3.3.24.1.9 | Columnrm10010e40AlmUpRdiInsPortn | read-only | current | MS-RDI/L-RDI Inserted On Line :This OID indicates an upstream MS-RDI/L-RDI has been inserted in the outgoing 10 Gb/s SDH/SONET signal. <Help> This status indic… |
| 1.3.6.1.4.1.20044.57.2.3.3.24.1.10 | Columnrm10010e40AlmLineDdmWarningPortn | read-only | current | Warning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Warning has… |
| 1.3.6.1.4.1.20044.57.2.3.3.24.1.11 | Columnrm10010e40AlmLineDdmAlmPortn | read-only | current | Alarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Alarm has been… |
| 1.3.6.1.4.1.20044.57.2.3.3.24.1.13 | Columnrm10010e40AlmLineFailPortn | read-only | current | Line Port Failure :This OID indicates a failure on the line port <Help> This alarm indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipm… |
| 1.3.6.1.4.1.20044.57.2.3.3.24.1.17 | Columnrm10010e40AlmLineActivePortn | read-only | current | Line Active :This OID indicates whether the line is active or standby. <Help> This status indicates whether the line is active or standby. <Condtype> LINE_ACTI… |
| 1.3.6.1.4.1.20044.57.3 | Noderm10010e40measures | |||
| 1.3.6.1.4.1.20044.57.3.1 | Noderm10010e40MesrOther | |||
| 1.3.6.1.4.1.20044.57.3.1.0 | Scalarrm10010e40Mesrsynth0 | read-only | deprecated | Not Used : |
| 1.3.6.1.4.1.20044.57.3.1.1 | Scalarrm10010e40Mesrsynth1 | read-only | deprecated | Not Used : |
| 1.3.6.1.4.1.20044.57.3.1.7 | Scalarrm10010e40MesrpmIntervalNumber | read-only | current | PM Interval Counter : |
| 1.3.6.1.4.1.20044.57.3.1.180 | Scalarrm10010e40MesrlineNetTxLaserOutputPwrAverage | read-only | current | Average Line Trscv Tx Power :This OID gives the average Tx Laser transmit power value among the network lanes of the Line Transceiver, read in the DDM (Digital… |
| 1.3.6.1.4.1.20044.57.3.1.181 | Scalarrm10010e40MesrlineNetTxLaserTempAverage | read-only | current | Average Line Trscv Tx Laser Temperature :This OID gives the average Tx Laser Temperature value among the network lanes of the Line Transceiver, read from the D… |
| 1.3.6.1.4.1.20044.57.3.1.182 | Scalarrm10010e40MesrlineNetTxBiasCurrentAverage | read-only | current | Average Line Trscv Tx Laser Bias :This OID gives the average Tx Laser Bias value among the network lanes of the Line Transceiver, read from the DDM (Digital Di… |
| 1.3.6.1.4.1.20044.57.3.1.183 | Scalarrm10010e40MesrlineNetRxInputPwrAverage | read-only | current | Average Line Trscv Rx Power :This OID gives the average Receive power value among the network lanes of the Line Transceiver, read in the DDM (Digital Diagnosti… |
| 1.3.6.1.4.1.20044.57.3.1.184 | Scalarrm10010e40MesrlineResidualChromaticDispAverage | read-only | current | Average Residual Chromatic Dispersion :This OID gives the average Residual Chromatic Dispersion on the Line interface since the last measure reset <Help> This … |
| 1.3.6.1.4.1.20044.57.3.1.185 | Scalarrm10010e40MesrlineDiffGroupDelayAverage | read-only | current | Average Differential Group Delay :This OID gives the average Group Delay on the Line interface since the last measure reset <Help> This measure gives the avera… |
| 1.3.6.1.4.1.20044.57.3.1.186 | Scalarrm10010e40MesrlineQFactorAverage | read-only | current | Average Q Factor :This OID gives the average Q Factor on the Line interface since the last measure reset <Help> This measure gives the average Q Factor on the … |
| 1.3.6.1.4.1.20044.57.3.1.187 | Scalarrm10010e40MesrlineCarrierFreqOffsetAverage | read-only | current | Average Carrier Frequency Offset :This OID gives the average Carrier Frequency Offset on the Line interface since the last measure reset <Help> This measure gi… |
| 1.3.6.1.4.1.20044.57.3.1.188 | Scalarrm10010e40MesrlineOsnrAverage | read-only | current | Average OSNR :This OID gives the average OSNR on the Line interface since the last measure reset <Help> This measure gives the average OSNR on the Line interfa… |
| 1.3.6.1.4.1.20044.57.3.1.192 | Scalarrm10010e40MesrclientNetTxTempMin | read-only | current | Min Client Trscv Laser Temperature :This OID gives the minimum Laser temperature value among the network lanes of the Client Transceiver, read from the DDM (Di… |
| 1.3.6.1.4.1.20044.57.3.1.193 | Scalarrm10010e40MesrclientNetTxBiasMin | read-only | current | Min Client Trscv Laser Bias :This OID gives the minimum Laser bias value among the network lanes of the Client Transceiver, read from the DDM (Digital Diagnost… |
| 1.3.6.1.4.1.20044.57.3.1.194 | Scalarrm10010e40MesrclientNetTxPwrMin | read-only | current | Min Client Trscv Tx Power :This OID gives the minimum transmit power value among the network lanes of the Client Transceiver, read from the DDM (Digital Diagno… |
| 1.3.6.1.4.1.20044.57.3.1.195 | Scalarrm10010e40MesrclientNetRxPwrMin | read-only | current | Min Client Trscv Rx Power :This OID gives the minimum receive power value among the network lanes of the Client Transceiver, read in the DDM (Digital Diagnosti… |
| 1.3.6.1.4.1.20044.57.3.1.196 | Scalarrm10010e40MesrlineNetTxLaserOutputPwrMin | read-only | current | Min Line Trscv Tx Power :This OID gives the minimum Tx Laser transmit power value among the network lanes of the Line Transceiver, read in the DDM (Digital Dia… |
| 1.3.6.1.4.1.20044.57.3.1.197 | Scalarrm10010e40MesrlineNetTxLaserTempMin | read-only | current | Min Line Trscv Tx Laser Temperature :This OID gives the minimum Tx Laser Temperature value among the network lanes of the Line Transceiver, read from the DDM (… |
| 1.3.6.1.4.1.20044.57.3.1.198 | Scalarrm10010e40MesrlineNetTxBiasCurrentMin | read-only | current | Min Line Trscv Tx Laser Bias :This OID gives the minimum Tx Laser Bias value among the network lanes of the Line Transceiver, read from the DDM (Digital Diagno… |
| 1.3.6.1.4.1.20044.57.3.1.199 | Scalarrm10010e40MesrlineNetRxInputPwrMin | read-only | current | Min Line Trscv Rx Power :This OID gives the minimum Receive power value among the network lanes of the Line Transceiver, read in the DDM (Digital Diagnostic Mo… |
| 1.3.6.1.4.1.20044.57.3.1.200 | Scalarrm10010e40MesrlineResidualChromaticDispMin | read-only | current | Min Residual Chromatic Dispersion :This OID gives the minimum Residual Chromatic Dispersion on the Line interface since the last measure reset (Unit = ps/nm)<H… |
| 1.3.6.1.4.1.20044.57.3.1.201 | Scalarrm10010e40MesrlineDiffGroupDelayMin | read-only | current | Min Differential Group Delay :This OID gives the minimum Differential Group Delay on the Line interface since the last measure reset (Unit = ps)<Help> This mea… |
| 1.3.6.1.4.1.20044.57.3.1.202 | Scalarrm10010e40MesrlineQFactorMin | read-only | current | Min Q Factor :This OID gives the minimum Q Factor on the Line interface since the last measure reset (Unit = dB)<Help> This measure gives the minimum Q Factor … |
| 1.3.6.1.4.1.20044.57.3.1.203 | Scalarrm10010e40MesrlineCarrierFreqOffsetMin | read-only | current | Min Carrier Frequency Offset :This OID gives the minimum Carrier Frequency Offset on the Line interface since the last measure reset (Unit = Mhz)<Help> This me… |
| 1.3.6.1.4.1.20044.57.3.1.204 | Scalarrm10010e40MesrlineOsnrMin | read-only | current | Min OSNR :This OID gives the minimum OSNR on the Line interface since the last measure reset (OSNR = AV/10) (Unit = dB)<Help> This measure gives the minimum OS… |
| 1.3.6.1.4.1.20044.57.3.1.208 | Scalarrm10010e40MesrclientNetTxTempMax | read-only | current | Max Client Trscv Laser Temperature :This OID gives the maximum Laser temperature value among the network lanes of the Client Transceiver, read from the DDM (Di… |
| 1.3.6.1.4.1.20044.57.3.1.209 | Scalarrm10010e40MesrclientNetTxBiasMax | read-only | current | Max Client Trscv Laser Bias :This OID gives the maximum Laser bias value among the network lanes of the Client Transceiver, read from the DDM (Digital Diagnost… |
| 1.3.6.1.4.1.20044.57.3.1.210 | Scalarrm10010e40MesrclientNetTxPwrMax | read-only | current | Max Client Trscv Tx Power :This OID gives the maximum transmit power value among the network lanes of the Client Transceiver, read from the DDM (Digital Diagno… |
| 1.3.6.1.4.1.20044.57.3.1.211 | Scalarrm10010e40MesrclientNetRxPwrMax | read-only | current | Max Client Trscv Rx Power :This OID gives the maximum receive power value among the network lanes of the Client Transceiver, read in the DDM (Digital Diagnosti… |
| 1.3.6.1.4.1.20044.57.3.1.212 | Scalarrm10010e40MesrlineNetTxLaserOutputPwrMax | read-only | current | Max Line Trscv Tx Power :This OID gives the maximum Tx Laser transmit power value among the network lanes of the Line Transceiver, read in the DDM (Digital Dia… |
| 1.3.6.1.4.1.20044.57.3.1.213 | Scalarrm10010e40MesrlineNetTxLaserTempMax | read-only | current | Max Line Trscv Tx Laser Temperature :This OID gives the maximum Tx Laser Temperature value among the network lanes of the Line Transceiver, read from the DDM (… |
| 1.3.6.1.4.1.20044.57.3.1.214 | Scalarrm10010e40MesrlineNetTxBiasCurrentMax | read-only | current | Max Line Trscv Tx Laser Bias :This OID gives the maximum Tx Laser Bias value among the network lanes of the Line Transceiver, read from the DDM (Digital Diagno… |
| 1.3.6.1.4.1.20044.57.3.1.215 | Scalarrm10010e40MesrlineNetRxInputPwrMax | read-only | current | Max Line Trscv Rx Power :This OID gives the maximum Receive power value among the network lanes of the Line Transceiver, read in the DDM (Digital Diagnostic Mo… |
| 1.3.6.1.4.1.20044.57.3.1.216 | Scalarrm10010e40MesrlineResidualChromaticDispMax | read-only | current | Max Residual Chromatic Dispersion :This OID gives the maximum Residual Chromatic Dispersion on the Line interface since the last measure reset (Unit = ps/nm)<H… |
| 1.3.6.1.4.1.20044.57.3.1.217 | Scalarrm10010e40MesrlineDiffGroupDelayMax | read-only | current | Max Differential Group Delay :This OID gives the maximum Differential Group Delay on the Line interface since the last measure reset (Unit = ps)<Help> This mea… |
| 1.3.6.1.4.1.20044.57.3.1.218 | Scalarrm10010e40MesrlineQFactorMax | read-only | current | Max Q Factor :This OID gives the maximum Q Factor on the Line interface since the last measure reset (Unit = dB)<Help> This measure gives the maximum Q Factor … |
| 1.3.6.1.4.1.20044.57.3.1.219 | Scalarrm10010e40MesrlineCarrierFreqOffsetMax | read-only | current | Max Carrier Frequency Offset :This OID gives the maximum Carrier Frequency Offset on the Line interface since the last measure reset (Unit = Mhz)<Help> This me… |
| 1.3.6.1.4.1.20044.57.3.1.220 | Scalarrm10010e40MesrlineOsnrMax | read-only | current | Max OSNR :This OID gives the maximum OSNR on the Line interface since the last measure reset (OSNR = AV/10) (Unit = dB)<Help> This measure gives the maximum OS… |
| 1.3.6.1.4.1.20044.57.3.2 | Noderm10010e40MesrClient | |||
| 1.3.6.1.4.1.20044.57.3.2.8 | Scalarrm10010e40MesrclientCfpTemp | read-only | current | Client Trscv Temperature :This OID gives the temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/2… |
| 1.3.6.1.4.1.20044.57.3.2.9 | Scalarrm10010e40MesrclientCfp3v3Voltage | read-only | current | Client Trscv Voltage :This OID gives the 3V3 voltage value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/1000) (Un… |
| 1.3.6.1.4.1.20044.57.3.2.10 | Scalarrm10010e40MesrclientSoaBiasCurrent | read-only | current | Client Trscv SOA Bias :This OID gives the SOA bias value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = m… |
| 1.3.6.1.4.1.20044.57.3.2.16 | Tablerm10010e40MesrclientNetTxTempTable | not-accessible | current | List of rm10010e40MesrclientNetTxTemp Article |
| 1.3.6.1.4.1.20044.57.3.2.16.1 | Rowrm10010e40MesrclientNetTxTempEntry | not-accessible | current | Row definition for the rm10010e40MesrclientNetTxTemp table |
| 1.3.6.1.4.1.20044.57.3.2.16.1.1 | Columnrm10010e40MesrclientNetTxTempIndex | read-only | current | Index definition for the rm10010e40MesrclientNetTxTemp table |
| 1.3.6.1.4.1.20044.57.3.2.16.1.2 | Columnrm10010e40MesrclientNetTxTempPortn | read-only | current | Client Trscv Temperature :This OID gives the Laser temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature … |
| 1.3.6.1.4.1.20044.57.3.2.32 | Tablerm10010e40MesrclientNetTxBiasTable | not-accessible | current | List of rm10010e40MesrclientNetTxBias Article |
| 1.3.6.1.4.1.20044.57.3.2.32.1 | Rowrm10010e40MesrclientNetTxBiasEntry | not-accessible | current | Row definition for the rm10010e40MesrclientNetTxBias table |
| 1.3.6.1.4.1.20044.57.3.2.32.1.1 | Columnrm10010e40MesrclientNetTxBiasIndex | read-only | current | Index definition for the rm10010e40MesrclientNetTxBias table |
| 1.3.6.1.4.1.20044.57.3.2.32.1.2 | Columnrm10010e40MesrclientNetTxBiasPortn | read-only | current | Client Trscv Laser Bias :This OID gives the Laser bias value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit… |
| 1.3.6.1.4.1.20044.57.3.2.48 | Tablerm10010e40MesrclientNetTxPwrTable | not-accessible | current | List of rm10010e40MesrclientNetTxPwr Article |
| 1.3.6.1.4.1.20044.57.3.2.48.1 | Rowrm10010e40MesrclientNetTxPwrEntry | not-accessible | current | Row definition for the rm10010e40MesrclientNetTxPwr table |
| 1.3.6.1.4.1.20044.57.3.2.48.1.1 | Columnrm10010e40MesrclientNetTxPwrIndex | read-only | current | Index definition for the rm10010e40MesrclientNetTxPwr table |
| 1.3.6.1.4.1.20044.57.3.2.48.1.2 | Columnrm10010e40MesrclientNetTxPwrPortn | read-only | current | Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)… |
| 1.3.6.1.4.1.20044.57.3.2.64 | Tablerm10010e40MesrclientNetRxPwrTable | not-accessible | current | List of rm10010e40MesrclientNetRxPwr Article |
| 1.3.6.1.4.1.20044.57.3.2.64.1 | Rowrm10010e40MesrclientNetRxPwrEntry | not-accessible | current | Row definition for the rm10010e40MesrclientNetRxPwr table |
| 1.3.6.1.4.1.20044.57.3.2.64.1.1 | Columnrm10010e40MesrclientNetRxPwrIndex | read-only | current | Index definition for the rm10010e40MesrclientNetRxPwr table |
| 1.3.6.1.4.1.20044.57.3.2.64.1.2 | Columnrm10010e40MesrclientNetRxPwrPortn | read-only | current | Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40… |
| 1.3.6.1.4.1.20044.57.3.3 | Noderm10010e40MesrLine | |||
| 1.3.6.1.4.1.20044.57.3.3.12 | Scalarrm10010e40MesrlineMsaTemp | read-only | current | Line Trscv Temperature :This OID gives the temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) … |
| 1.3.6.1.4.1.20044.57.3.3.13 | Scalarrm10010e40MesrlineMsa3v3Voltage | read-only | current | Line Trscv Voltage :This OID gives the 3V3 voltage value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/1000) (Unit =… |
| 1.3.6.1.4.1.20044.57.3.3.14 | Scalarrm10010e40MesrlineSoaBiasCurrent | read-only | current | Line Trscv SOA Bias :This OID gives the SOA bias value of the Line Transceiver,read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <H… |
| 1.3.6.1.4.1.20044.57.3.3.80 | Tablerm10010e40MesrlineNetTxLaserOutputPwrTable | not-accessible | current | List of rm10010e40MesrlineNetTxLaserOutputPwr Article |
| 1.3.6.1.4.1.20044.57.3.3.80.1 | Rowrm10010e40MesrlineNetTxLaserOutputPwrEntry | not-accessible | current | Row definition for the rm10010e40MesrlineNetTxLaserOutputPwr table |
| 1.3.6.1.4.1.20044.57.3.3.80.1.1 | Columnrm10010e40MesrlineNetTxLaserOutputPwrIndex | read-only | current | Index definition for the rm10010e40MesrlineNetTxLaserOutputPwr table |
| 1.3.6.1.4.1.20044.57.3.3.80.1.2 | Columnrm10010e40MesrlineNetTxLaserOutputPwrPortn | read-only | current | Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power =… |
| 1.3.6.1.4.1.20044.57.3.3.96 | Tablerm10010e40MesrlineNetTxLaserTempTable | not-accessible | current | List of rm10010e40MesrlineNetTxLaserTemp Article |
| 1.3.6.1.4.1.20044.57.3.3.96.1 | Rowrm10010e40MesrlineNetTxLaserTempEntry | not-accessible | current | Row definition for the rm10010e40MesrlineNetTxLaserTemp table |
| 1.3.6.1.4.1.20044.57.3.3.96.1.1 | Columnrm10010e40MesrlineNetTxLaserTempIndex | read-only | current | Index definition for the rm10010e40MesrlineNetTxLaserTemp table |
| 1.3.6.1.4.1.20044.57.3.3.96.1.2 | Columnrm10010e40MesrlineNetTxLaserTempPortn | read-only | current | Current Line Trscv Tx Laser Temperature :This OID gives the Tx Laser Temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitorin… |
| 1.3.6.1.4.1.20044.57.3.3.112 | Tablerm10010e40MesrlineNetTxBiasCurrentTable | not-accessible | current | List of rm10010e40MesrlineNetTxBiasCurrent Article |
| 1.3.6.1.4.1.20044.57.3.3.112.1 | Rowrm10010e40MesrlineNetTxBiasCurrentEntry | not-accessible | current | Row definition for the rm10010e40MesrlineNetTxBiasCurrent table |
| 1.3.6.1.4.1.20044.57.3.3.112.1.1 | Columnrm10010e40MesrlineNetTxBiasCurrentIndex | read-only | current | Index definition for the rm10010e40MesrlineNetTxBiasCurrent table |
| 1.3.6.1.4.1.20044.57.3.3.112.1.2 | Columnrm10010e40MesrlineNetTxBiasCurrentPortn | read-only | current | Current Line Trscv Tx Laser Bias :This OID gives the Tx Laser Bias value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/… |
| 1.3.6.1.4.1.20044.57.3.3.128 | Tablerm10010e40MesrlineNetRxInputPwrTable | not-accessible | current | List of rm10010e40MesrlineNetRxInputPwr Article |
| 1.3.6.1.4.1.20044.57.3.3.128.1 | Rowrm10010e40MesrlineNetRxInputPwrEntry | not-accessible | current | Row definition for the rm10010e40MesrlineNetRxInputPwr table |
| 1.3.6.1.4.1.20044.57.3.3.128.1.1 | Columnrm10010e40MesrlineNetRxInputPwrIndex | read-only | current | Index definition for the rm10010e40MesrlineNetRxInputPwr table |
| 1.3.6.1.4.1.20044.57.3.3.128.1.2 | Columnrm10010e40MesrlineNetRxInputPwrPortn | read-only | current | Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (… |
| 1.3.6.1.4.1.20044.57.3.3.144 | Tablerm10010e40MesrlineResidualChromaticDispTable | not-accessible | current | List of rm10010e40MesrlineResidualChromaticDisp Article |
| 1.3.6.1.4.1.20044.57.3.3.144.1 | Rowrm10010e40MesrlineResidualChromaticDispEntry | not-accessible | current | Row definition for the rm10010e40MesrlineResidualChromaticDisp table |
| 1.3.6.1.4.1.20044.57.3.3.144.1.1 | Columnrm10010e40MesrlineResidualChromaticDispIndex | read-only | current | Index definition for the rm10010e40MesrlineResidualChromaticDisp table |
| 1.3.6.1.4.1.20044.57.3.3.144.1.2 | Columnrm10010e40MesrlineResidualChromaticDispPortn | read-only | current | Current Residual Chromatic Dispersion :This OID gives the current Residual Chromatic Dispersion on the Line interface (Unit = ps/nm)<Help> This measure gives t… |
| 1.3.6.1.4.1.20044.57.3.3.148 | Tablerm10010e40MesrlineDiffGroupDelayTable | not-accessible | current | List of rm10010e40MesrlineDiffGroupDelay Article |
| 1.3.6.1.4.1.20044.57.3.3.148.1 | Rowrm10010e40MesrlineDiffGroupDelayEntry | not-accessible | current | Row definition for the rm10010e40MesrlineDiffGroupDelay table |
| 1.3.6.1.4.1.20044.57.3.3.148.1.1 | Columnrm10010e40MesrlineDiffGroupDelayIndex | read-only | current | Index definition for the rm10010e40MesrlineDiffGroupDelay table |
| 1.3.6.1.4.1.20044.57.3.3.148.1.2 | Columnrm10010e40MesrlineDiffGroupDelayPortn | read-only | current | Current Differential Group Delay :This OID gives the current Differential Group Delay on the Line interface (Unit = ps)<Help> This measure gives the current Di… |
| 1.3.6.1.4.1.20044.57.3.3.152 | Tablerm10010e40MesrlineQFactorTable | not-accessible | current | List of rm10010e40MesrlineQFactor Article |
| 1.3.6.1.4.1.20044.57.3.3.152.1 | Rowrm10010e40MesrlineQFactorEntry | not-accessible | current | Row definition for the rm10010e40MesrlineQFactor table |
| 1.3.6.1.4.1.20044.57.3.3.152.1.1 | Columnrm10010e40MesrlineQFactorIndex | read-only | current | Index definition for the rm10010e40MesrlineQFactor table |
| 1.3.6.1.4.1.20044.57.3.3.152.1.2 | Columnrm10010e40MesrlineQFactorPortn | read-only | current | Current Q Factor :This OID gives the current Q Factor on the Line interface (Unit = dB) <Help> This measure gives the current Q Factor on the Line interface. |
| 1.3.6.1.4.1.20044.57.3.3.156 | Tablerm10010e40MesrlineCarrierFreqOffsetTable | not-accessible | current | List of rm10010e40MesrlineCarrierFreqOffset Article |
| 1.3.6.1.4.1.20044.57.3.3.156.1 | Rowrm10010e40MesrlineCarrierFreqOffsetEntry | not-accessible | current | Row definition for the rm10010e40MesrlineCarrierFreqOffset table |
| 1.3.6.1.4.1.20044.57.3.3.156.1.1 | Columnrm10010e40MesrlineCarrierFreqOffsetIndex | read-only | current | Index definition for the rm10010e40MesrlineCarrierFreqOffset table |
| 1.3.6.1.4.1.20044.57.3.3.156.1.2 | Columnrm10010e40MesrlineCarrierFreqOffsetPortn | read-only | current | Current Carrier Frequency Offset :This OID gives the current Carrier Frequency Offset on the Line interface (Unit = Mhz)<Help> This measure gives the current C… |
| 1.3.6.1.4.1.20044.57.3.3.160 | Tablerm10010e40MesrlineOsnrTable | not-accessible | current | List of rm10010e40MesrlineOsnr Article |
| 1.3.6.1.4.1.20044.57.3.3.160.1 | Rowrm10010e40MesrlineOsnrEntry | not-accessible | current | Row definition for the rm10010e40MesrlineOsnr table |
| 1.3.6.1.4.1.20044.57.3.3.160.1.1 | Columnrm10010e40MesrlineOsnrIndex | read-only | current | Index definition for the rm10010e40MesrlineOsnr table |
| 1.3.6.1.4.1.20044.57.3.3.160.1.2 | Columnrm10010e40MesrlineOsnrPortn | read-only | current | Current OSNR :This OID gives the current OSNR on the Line interface (OSNR = AV/10) (Unit = dB) <Help> This measure gives the current OSNR on the Line interface. |
| 1.3.6.1.4.1.20044.57.4 | Noderm10010e40counters | |||
| 1.3.6.1.4.1.20044.57.4.1 | Noderm10010e40CntOther | |||
| 1.3.6.1.4.1.20044.57.4.2 | Noderm10010e40CntClient | |||
| 1.3.6.1.4.1.20044.57.4.2.16 | Tablerm10010e40CntclientInputErrorCounterLaneOneTable | not-accessible | current | List of rm10010e40CntclientInputErrorCounterLaneOne Article |
| 1.3.6.1.4.1.20044.57.4.2.16.1 | Rowrm10010e40CntclientInputErrorCounterLaneOneEntry | not-accessible | current | Row definition for the rm10010e40CntclientInputErrorCounterLaneOne table |
| 1.3.6.1.4.1.20044.57.4.2.16.1.1 | Columnrm10010e40CntclientInputErrorCounterLaneOneIndex | read-only | current | Index definition for the rm10010e40CntclientInputErrorCounterLaneOne table |
| 1.3.6.1.4.1.20044.57.4.2.16.1.2 | Columnrm10010e40CntclientInputErrorCounterLaneOneValuePortn | read-only | current | Client_Input_Error_Counter_Lane1 :This counter is incremented each time a coding violation is detected on the host lane of the client transceiver <Help> This c… |
| 1.3.6.1.4.1.20044.57.4.2.16.1.3 | Columnrm10010e40CntclientInputErrorCounterLaneOneErrorPortn | read-only | current | Client Input Counter Error :This OID when set indicates the rate adaptation removal counter value is invalid on Port |
| 1.3.6.1.4.1.20044.57.4.2.16.1.4 | Columnrm10010e40CntclientInputErrorCounterLaneOneOverloadPortn | read-only | current | Client Input Counter Overload :This OID when set indicates a rate adaptation removal counter overload on Port |
| 1.3.6.1.4.1.20044.57.4.2.32 | Tablerm10010e40CntclientInputErrorCounterLaneTwoTable | not-accessible | current | List of rm10010e40CntclientInputErrorCounterLaneTwo Article |
| 1.3.6.1.4.1.20044.57.4.2.32.1 | Rowrm10010e40CntclientInputErrorCounterLaneTwoEntry | not-accessible | current | Row definition for the rm10010e40CntclientInputErrorCounterLaneTwo table |
| 1.3.6.1.4.1.20044.57.4.2.32.1.1 | Columnrm10010e40CntclientInputErrorCounterLaneTwoIndex | read-only | current | Index definition for the rm10010e40CntclientInputErrorCounterLaneTwo table |
| 1.3.6.1.4.1.20044.57.4.2.32.1.2 | Columnrm10010e40CntclientInputErrorCounterLaneTwoValuePortn | read-only | current | Client_Input_Error_Counter_Lane2 :This counter is incremented each time a coding violation is detected on the host lane of the client transceiver <Help> This c… |
| 1.3.6.1.4.1.20044.57.4.2.32.1.3 | Columnrm10010e40CntclientInputErrorCounterLaneTwoErrorPortn | read-only | current | Client Input Counter Error :This OID when set indicates the client error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.57.4.2.32.1.4 | Columnrm10010e40CntclientInputErrorCounterLaneTwoOverloadPortn | read-only | current | Client Input Counter Overload :This OID when set indicates a client input error counter overload on Port |
| 1.3.6.1.4.1.20044.57.4.2.80 | Tablerm10010e40CntclientInputErrorCounterTable | not-accessible | current | List of rm10010e40CntclientInputErrorCounter Article |
| 1.3.6.1.4.1.20044.57.4.2.80.1 | Rowrm10010e40CntclientInputErrorCounterEntry | not-accessible | current | Row definition for the rm10010e40CntclientInputErrorCounter table |
| 1.3.6.1.4.1.20044.57.4.2.80.1.1 | Columnrm10010e40CntclientInputErrorCounterIndex | read-only | current | Index definition for the rm10010e40CntclientInputErrorCounter table |
| 1.3.6.1.4.1.20044.57.4.2.80.1.2 | Columnrm10010e40CntclientInputErrorCounterValuePortn | read-only | current | Client Input Errors :This counter is increased each time a 10b/8b running disparity error is detected on the Client input stream <Help> This counter gives the … |
| 1.3.6.1.4.1.20044.57.4.2.80.1.3 | Columnrm10010e40CntclientInputErrorCounterErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the client error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.57.4.2.80.1.4 | Columnrm10010e40CntclientInputErrorCounterOverloadPortn | read-only | current | Client Counter Overload :This OID when set indicates a client input error counter overload on Port |
| 1.3.6.1.4.1.20044.57.4.2.96 | Tablerm10010e40CntclientCbipCounterTable | not-accessible | current | List of rm10010e40CntclientCbipCounter Article |
| 1.3.6.1.4.1.20044.57.4.2.96.1 | Rowrm10010e40CntclientCbipCounterEntry | not-accessible | current | Row definition for the rm10010e40CntclientCbipCounter table |
| 1.3.6.1.4.1.20044.57.4.2.96.1.1 | Columnrm10010e40CntclientCbipCounterIndex | read-only | current | Index definition for the rm10010e40CntclientCbipCounter table |
| 1.3.6.1.4.1.20044.57.4.2.96.1.2 | Columnrm10010e40CntclientCbipCounterValuePortn | read-only | current | Client Output Errors :This counter is incremented each time a CBIP parity error is detected on the Client output stream <Help> This counter gives the number of… |
| 1.3.6.1.4.1.20044.57.4.2.96.1.3 | Columnrm10010e40CntclientCbipCounterErrorPortn | read-only | current | Client Counter Error :This OID when set indicates the CBIP error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.57.4.2.96.1.4 | Columnrm10010e40CntclientCbipCounterOverloadPortn | read-only | current | Client CBIP Counter Overload :This OID when set indicates a CBIP error counter overload on Port |
| 1.3.6.1.4.1.20044.57.4.3 | Noderm10010e40CntLine | |||
| 1.3.6.1.4.1.20044.57.4.3.192 | Tablerm10010e40CntlocalLineSmBip8ErrorCounterTable | not-accessible | current | List of rm10010e40CntlocalLineSmBip8ErrorCounter Article |
| 1.3.6.1.4.1.20044.57.4.3.192.1 | Rowrm10010e40CntlocalLineSmBip8ErrorCounterEntry | not-accessible | current | Row definition for the rm10010e40CntlocalLineSmBip8ErrorCounter table |
| 1.3.6.1.4.1.20044.57.4.3.192.1.1 | Columnrm10010e40CntlocalLineSmBip8ErrorCounterIndex | read-only | current | Index definition for the rm10010e40CntlocalLineSmBip8ErrorCounter table |
| 1.3.6.1.4.1.20044.57.4.3.192.1.2 | Columnrm10010e40CntlocalLineSmBip8ErrorCounterValuePortn | read-only | current | Line Input SM-BIP8 Errors :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC <Help> This counter gives the current Bit Error Rate (r… |
| 1.3.6.1.4.1.20044.57.4.3.192.1.3 | Columnrm10010e40CntlocalLineSmBip8ErrorCounterErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the B1 error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.57.4.3.192.1.4 | Columnrm10010e40CntlocalLineSmBip8ErrorCounterOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a B1 error counter overload on Port |
| 1.3.6.1.4.1.20044.57.4.3.193 | Tablerm10010e40CntlocalLineFecCorrectedErrorsCounterTable | not-accessible | current | List of rm10010e40CntlocalLineFecCorrectedErrorsCounter Article |
| 1.3.6.1.4.1.20044.57.4.3.193.1 | Rowrm10010e40CntlocalLineFecCorrectedErrorsCounterEntry | not-accessible | current | Row definition for the rm10010e40CntlocalLineFecCorrectedErrorsCounter table |
| 1.3.6.1.4.1.20044.57.4.3.193.1.1 | Columnrm10010e40CntlocalLineFecCorrectedErrorsCounterIndex | read-only | current | Index definition for the rm10010e40CntlocalLineFecCorrectedErrorsCounter table |
| 1.3.6.1.4.1.20044.57.4.3.193.1.2 | Columnrm10010e40CntlocalLineFecCorrectedErrorsCounterValuePortn | read-only | current | Line Input HD FEC Corrected Errors :This OID gives the current Bit Error Rate before the Hard Decision FEC <Help> This counter gives the current Bit Error Rate… |
| 1.3.6.1.4.1.20044.57.4.3.193.1.3 | Columnrm10010e40CntlocalLineFecCorrectedErrorsCounterErrorPortn | read-only | current | FEC Counter Error :This bit when set indicates the FEC corrected errors counter value is invalid on Line |
| 1.3.6.1.4.1.20044.57.4.3.193.1.4 | Columnrm10010e40CntlocalLineFecCorrectedErrorsCounterOverloadPortn | read-only | current | FEC Counter Overload :This bit when set indicates a FEC corrected errors counter overload on Line |
| 1.3.6.1.4.1.20044.57.4.3.194 | Tablerm10010e40CntremoteLineSmBip8ErrorCounterTable | not-accessible | current | List of rm10010e40CntremoteLineSmBip8ErrorCounter Article |
| 1.3.6.1.4.1.20044.57.4.3.194.1 | Rowrm10010e40CntremoteLineSmBip8ErrorCounterEntry | not-accessible | current | Row definition for the rm10010e40CntremoteLineSmBip8ErrorCounter table |
| 1.3.6.1.4.1.20044.57.4.3.194.1.1 | Columnrm10010e40CntremoteLineSmBip8ErrorCounterIndex | read-only | current | Index definition for the rm10010e40CntremoteLineSmBip8ErrorCounter table |
| 1.3.6.1.4.1.20044.57.4.3.194.1.2 | Columnrm10010e40CntremoteLineSmBip8ErrorCounterValuePortn | read-only | current | Remote SM BIP8 :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC on the remote side <Help> This counter gives the current Bit Error… |
| 1.3.6.1.4.1.20044.57.4.3.194.1.3 | Columnrm10010e40CntremoteLineSmBip8ErrorCounterErrorPortn | read-only | current | Remote Counter Error : |
| 1.3.6.1.4.1.20044.57.4.3.194.1.4 | Columnrm10010e40CntremoteLineSmBip8ErrorCounterOverloadPortn | read-only | current | Remote Counter Overload : |
| 1.3.6.1.4.1.20044.57.4.3.195 | Tablerm10010e40CntlineDfrmTimCntTable | not-accessible | current | List of rm10010e40CntlineDfrmTimCnt Article |
| 1.3.6.1.4.1.20044.57.4.3.195.1 | Rowrm10010e40CntlineDfrmTimCntEntry | not-accessible | current | Row definition for the rm10010e40CntlineDfrmTimCnt table |
| 1.3.6.1.4.1.20044.57.4.3.195.1.1 | Columnrm10010e40CntlineDfrmTimCntIndex | read-only | current | Index definition for the rm10010e40CntlineDfrmTimCnt table |
| 1.3.6.1.4.1.20044.57.4.3.195.1.2 | Columnrm10010e40CntlineDfrmTimCntValuePortn | read-only | current | Line Timer Counter : |
| 1.3.6.1.4.1.20044.57.4.3.195.1.3 | Columnrm10010e40CntlineDfrmTimCntErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.57.4.3.195.1.4 | Columnrm10010e40CntlineDfrmTimCntOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.57.4.3.196 | Tablerm10010e40CntlocalLineTrscvFecCorrectedErrorCounterTable | not-accessible | current | List of rm10010e40CntlocalLineTrscvFecCorrectedErrorCounter Article |
| 1.3.6.1.4.1.20044.57.4.3.196.1 | Rowrm10010e40CntlocalLineTrscvFecCorrectedErrorCounterEntry | not-accessible | current | Row definition for the rm10010e40CntlocalLineTrscvFecCorrectedErrorCounter table |
| 1.3.6.1.4.1.20044.57.4.3.196.1.1 | Columnrm10010e40CntlocalLineTrscvFecCorrectedErrorCounterIndex | read-only | current | Index definition for the rm10010e40CntlocalLineTrscvFecCorrectedErrorCounter table |
| 1.3.6.1.4.1.20044.57.4.3.196.1.2 | Columnrm10010e40CntlocalLineTrscvFecCorrectedErrorCounterValuePortn | read-only | current | Line Input SD FEC Corrected Errors :This OID gives the current Bit Error Rate before the Soft Decision FEC <Help> This counter gives the current Bit Error Rate… |
| 1.3.6.1.4.1.20044.57.4.3.196.1.3 | Columnrm10010e40CntlocalLineTrscvFecCorrectedErrorCounterErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.57.4.3.196.1.4 | Columnrm10010e40CntlocalLineTrscvFecCorrectedErrorCounterOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.57.4.3.197 | Tablerm10010e40CntlocalLineTrscvFecUncorrectedErrorCounterTable | not-accessible | current | List of rm10010e40CntlocalLineTrscvFecUncorrectedErrorCounter Article |
| 1.3.6.1.4.1.20044.57.4.3.197.1 | Rowrm10010e40CntlocalLineTrscvFecUncorrectedErrorCounterEntry | not-accessible | current | Row definition for the rm10010e40CntlocalLineTrscvFecUncorrectedErrorCounter table |
| 1.3.6.1.4.1.20044.57.4.3.197.1.1 | Columnrm10010e40CntlocalLineTrscvFecUncorrectedErrorCounterIndex | read-only | current | Index definition for the rm10010e40CntlocalLineTrscvFecUncorrectedErrorCounter table |
| 1.3.6.1.4.1.20044.57.4.3.197.1.2 | Columnrm10010e40CntlocalLineTrscvFecUncorrectedErrorCounterValuePortn | read-only | current | SD Uncorrected :This OID gives the current Bit Error Rate after the Soft Decision FEC (residual) <Help> This counter gives the current Bit Error Rate after the… |
| 1.3.6.1.4.1.20044.57.4.3.197.1.3 | Columnrm10010e40CntlocalLineTrscvFecUncorrectedErrorCounterErrorPortn | read-only | current | Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port |
| 1.3.6.1.4.1.20044.57.4.3.197.1.4 | Columnrm10010e40CntlocalLineTrscvFecUncorrectedErrorCounterOverloadPortn | read-only | current | Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port |
| 1.3.6.1.4.1.20044.57.6 | Noderm10010e40controlsWrite | |||
| 1.3.6.1.4.1.20044.57.6.1 | Noderm10010e40CtrlOther | |||
| 1.3.6.1.4.1.20044.57.6.1.1 | Noderm10010e40CtrlconfMgnt1 | |||
| 1.3.6.1.4.1.20044.57.6.1.1.1 | Scalarrm10010e40CtrlConf1Load1 | read-write | current | Load Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM. |
| 1.3.6.1.4.1.20044.57.6.1.1.2 | Scalarrm10010e40CtrlConf2Load1 | read-write | current | Load Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM. |
| 1.3.6.1.4.1.20044.57.6.1.1.10 | Scalarrm10010e40CtrlConf2Flash1 | read-write | current | Write Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura… |
| 1.3.6.1.4.1.20044.57.6.1.1.14 | Scalarrm10010e40CtrlConf2Clear1 | read-write | current | Clear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o… |
| 1.3.6.1.4.1.20044.57.6.1.4 | Noderm10010e40Ctrlsynth4 | |||
| 1.3.6.1.4.1.20044.57.6.1.4.1 | Scalarrm10010e40CtrlCorrelatOn | read-write | current | Enable Alarm Correlation :This OID enables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.57.6.1.4.2 | Scalarrm10010e40CtrlCorrelatOff | read-write | current | Disable Alarm Correlation :This OID disables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.57.6.1.5 | Noderm10010e40CtrlswMgnt | |||
| 1.3.6.1.4.1.20044.57.6.1.5.2 | Scalarrm10010e40CtrlColdReset | read-write | current | PM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> … |
| 1.3.6.1.4.1.20044.57.6.1.5.3 | Scalarrm10010e40CtrlWarmReset | read-write | current | PM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th… |
| 1.3.6.1.4.1.20044.57.6.1.5.5 | Scalarrm10010e40CtrlLoadSwBank1 | read-write | current | Set Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW… |
| 1.3.6.1.4.1.20044.57.6.1.5.6 | Scalarrm10010e40CtrlLoadSwBank2 | read-write | current | Set Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S… |
| 1.3.6.1.4.1.20044.57.6.1.6 | Noderm10010e40CtrlgwMgnt | |||
| 1.3.6.1.4.1.20044.57.6.1.6.1 | Scalarrm10010e40CtrlCurrentGwReset | read-write | current | Active Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting. |
| 1.3.6.1.4.1.20044.57.6.1.6.5 | Scalarrm10010e40CtrlLoadGwBank1 | read-write | current | Set Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.57.6.1.6.6 | Scalarrm10010e40CtrlLoadGwBank2 | read-write | current | Set Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.57.6.1.6.7 | Scalarrm10010e40CtrlLoadGwBank3 | read-write | current | Set Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c… |
| 1.3.6.1.4.1.20044.57.6.1.6.8 | Scalarrm10010e40CtrlLoadGwBank4 | read-write | current | Set Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset. |
| 1.3.6.1.4.1.20044.57.6.1.192 | Noderm10010e40CtrlledTest | |||
| 1.3.6.1.4.1.20044.57.6.1.192.1 | Scalarrm10010e40CtrlGreenLed | read-write | current | Green Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green |
| 1.3.6.1.4.1.20044.57.6.1.192.2 | Scalarrm10010e40CtrlRedLed | read-write | current | Red Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red |
| 1.3.6.1.4.1.20044.57.6.1.192.3 | Scalarrm10010e40CtrlLedOff | read-write | current | Leds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF |
| 1.3.6.1.4.1.20044.57.6.1.201 | Noderm10010e40CtrlinitSwitchMarvell | |||
| 1.3.6.1.4.1.20044.57.6.1.201.1 | Scalarrm10010e40CtrlInitSwitchMarvell | read-write | current | Switch Initialization :This OID operates an initialization of the switch managed through the module <Help> This control activates an initialization of the swit… |
| 1.3.6.1.4.1.20044.57.6.1.259 | Noderm10010e40CtrlresetCount | |||
| 1.3.6.1.4.1.20044.57.6.1.259.1 | Scalarrm10010e40CtrlResetcount | read-write | current | Module Count Global Reset :This OID resets all the errors counters on the module <Help > This control initiates a reset of the errors counters on the module |
| 1.3.6.1.4.1.20044.57.6.1.260 | Noderm10010e40CtrlresetRmon | |||
| 1.3.6.1.4.1.20044.57.6.1.260.1 | Scalarrm10010e40CtrlResetrmon | read-write | current | Module Rmon Global Reset :This OID resets all the Rmon counters on the module <Help > This control initiates a reset of the Rmon counters on the module |
| 1.3.6.1.4.1.20044.57.6.1.261 | Noderm10010e40CtrlresetMeasurements | |||
| 1.3.6.1.4.1.20044.57.6.1.261.1 | Scalarrm10010e40CtrlResetmeasurements | read-write | current | Management Meas Global Reset :This OID resets some measurements on the management <Help > This control initiates a reset of some measurements on the management |
| 1.3.6.1.4.1.20044.57.6.2 | Noderm10010e40CtrlClient | |||
| 1.3.6.1.4.1.20044.57.6.2.16 | Tablerm10010e40CtrlaccessLoopTable | not-accessible | current | List of rm10010e40CtrlaccessLoop Article |
| 1.3.6.1.4.1.20044.57.6.2.16.1 | Rowrm10010e40CtrlaccessLoopEntry | not-accessible | current | Row definition for the rm10010e40CtrlaccessLoop table |
| 1.3.6.1.4.1.20044.57.6.2.16.1.1 | Columnrm10010e40CtrlaccessLoopIndex | read-only | current | Index definition for the rm10010e40CtrlaccessLoop table |
| 1.3.6.1.4.1.20044.57.6.2.16.1.2 | Columnrm10010e40CtrlaccessLoopPortn | read-write | current | Client Facility Loopback :This OID, when set at '1' puts the client port in loopback, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. <Help… |
| 1.3.6.1.4.1.20044.57.6.2.17 | Tablerm10010e40CtrlclientLoopToLineTable | not-accessible | current | List of rm10010e40CtrlclientLoopToLine Article |
| 1.3.6.1.4.1.20044.57.6.2.17.1 | Rowrm10010e40CtrlclientLoopToLineEntry | not-accessible | current | Row definition for the rm10010e40CtrlclientLoopToLine table |
| 1.3.6.1.4.1.20044.57.6.2.17.1.1 | Columnrm10010e40CtrlclientLoopToLineIndex | read-only | current | Index definition for the rm10010e40CtrlclientLoopToLine table |
| 1.3.6.1.4.1.20044.57.6.2.17.1.2 | Columnrm10010e40CtrlclientLoopToLinePortn | read-write | current | Client Terminal Loopback :This OID, when set, puts the client port in loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.<Help> This control ena… |
| 1.3.6.1.4.1.20044.57.6.2.21 | Tablerm10010e40CtrlcsfUpInsTable | not-accessible | current | List of rm10010e40CtrlcsfUpIns Article |
| 1.3.6.1.4.1.20044.57.6.2.21.1 | Rowrm10010e40CtrlcsfUpInsEntry | not-accessible | current | Row definition for the rm10010e40CtrlcsfUpIns table |
| 1.3.6.1.4.1.20044.57.6.2.21.1.1 | Columnrm10010e40CtrlcsfUpInsIndex | read-only | current | Index definition for the rm10010e40CtrlcsfUpIns table |
| 1.3.6.1.4.1.20044.57.6.2.21.1.2 | Columnrm10010e40CtrlcsfUpInsPortn | read-write | current | Client Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo… |
| 1.3.6.1.4.1.20044.57.6.2.22 | Tablerm10010e40CtrlcaisDwInsTable | not-accessible | current | List of rm10010e40CtrlcaisDwIns Article |
| 1.3.6.1.4.1.20044.57.6.2.22.1 | Rowrm10010e40CtrlcaisDwInsEntry | not-accessible | current | Row definition for the rm10010e40CtrlcaisDwIns table |
| 1.3.6.1.4.1.20044.57.6.2.22.1.1 | Columnrm10010e40CtrlcaisDwInsIndex | read-only | current | Index definition for the rm10010e40CtrlcaisDwIns table |
| 1.3.6.1.4.1.20044.57.6.2.22.1.2 | Columnrm10010e40CtrlcaisDwInsPortn | read-write | current | Client AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port |
| 1.3.6.1.4.1.20044.57.6.3 | Noderm10010e40CtrlLine | |||
| 1.3.6.1.4.1.20044.57.6.3.64 | Tablerm10010e40CtrlcommAccessLoopTable | not-accessible | current | List of rm10010e40CtrlcommAccessLoop Article |
| 1.3.6.1.4.1.20044.57.6.3.64.1 | Rowrm10010e40CtrlcommAccessLoopEntry | not-accessible | current | Row definition for the rm10010e40CtrlcommAccessLoop table |
| 1.3.6.1.4.1.20044.57.6.3.64.1.1 | Columnrm10010e40CtrlcommAccessLoopIndex | read-only | current | Index definition for the rm10010e40CtrlcommAccessLoop table |
| 1.3.6.1.4.1.20044.57.6.3.64.1.2 | Columnrm10010e40CtrlcommAccessLoopPortn | read-write | current | Line Terminal Loopback :This OID, when set, puts the module in common access loop back, looping the 100 Gb/s output signal on the 100 Gb/s input.<Help> This co… |
| 1.3.6.1.4.1.20044.57.6.3.66 | Tablerm10010e40CtrllineLoopTable | not-accessible | current | List of rm10010e40CtrllineLoop Article |
| 1.3.6.1.4.1.20044.57.6.3.66.1 | Rowrm10010e40CtrllineLoopEntry | not-accessible | current | Row definition for the rm10010e40CtrllineLoop table |
| 1.3.6.1.4.1.20044.57.6.3.66.1.1 | Columnrm10010e40CtrllineLoopIndex | read-only | current | Index definition for the rm10010e40CtrllineLoop table |
| 1.3.6.1.4.1.20044.57.6.3.66.1.2 | Columnrm10010e40CtrllineLoopPortn | read-write | current | Line Facility Loopback :This OID, when set at '1' puts the module in line loopback mode, looping the received 100 Gb/s signal on the transmit 100 Gb/s output. … |
| 1.3.6.1.4.1.20044.57.6.3.69 | Tablerm10010e40CtrlfecDisableTable | not-accessible | current | List of rm10010e40CtrlfecDisable Article |
| 1.3.6.1.4.1.20044.57.6.3.69.1 | Rowrm10010e40CtrlfecDisableEntry | not-accessible | current | Row definition for the rm10010e40CtrlfecDisable table |
| 1.3.6.1.4.1.20044.57.6.3.69.1.1 | Columnrm10010e40CtrlfecDisableIndex | read-only | current | Index definition for the rm10010e40CtrlfecDisable table |
| 1.3.6.1.4.1.20044.57.6.3.69.1.2 | Columnrm10010e40CtrlfecDisablePortn | read-write | current | Forward Error Correction Inhibition :This OID, when set, inhibits the Forward Error Correction feature on the line input <Help> This control enables/disables t… |
| 1.3.6.1.4.1.20044.57.6.3.209 | Tablerm10010e40CtrlmsaLineLoopTable | not-accessible | current | List of rm10010e40CtrlmsaLineLoop Article |
| 1.3.6.1.4.1.20044.57.6.3.209.1 | Rowrm10010e40CtrlmsaLineLoopEntry | not-accessible | current | Row definition for the rm10010e40CtrlmsaLineLoop table |
| 1.3.6.1.4.1.20044.57.6.3.209.1.1 | Columnrm10010e40CtrlmsaLineLoopIndex | read-only | current | Index definition for the rm10010e40CtrlmsaLineLoop table |
| 1.3.6.1.4.1.20044.57.6.3.209.1.2 | Columnrm10010e40CtrlmsaLineLoopPortn | read-write | current | MSA Line Loop :This OID operates a line loopback on the MSA Line <Help> This control defines the line loop back of the line transceiver |
| 1.3.6.1.4.1.20044.57.6.3.210 | Tablerm10010e40CtrlmsaTxResetTable | not-accessible | current | List of rm10010e40CtrlmsaTxReset Article |
| 1.3.6.1.4.1.20044.57.6.3.210.1 | Rowrm10010e40CtrlmsaTxResetEntry | not-accessible | current | Row definition for the rm10010e40CtrlmsaTxReset table |
| 1.3.6.1.4.1.20044.57.6.3.210.1.1 | Columnrm10010e40CtrlmsaTxResetIndex | read-only | current | Index definition for the rm10010e40CtrlmsaTxReset table |
| 1.3.6.1.4.1.20044.57.6.3.210.1.2 | Columnrm10010e40CtrlmsaTxResetPortn | read-write | current | Line MSA TX Reset :This OID resets the TX portion of the MSA line module <Help > This control initiates a reset of the transmitting side |
| 1.3.6.1.4.1.20044.57.6.3.211 | Tablerm10010e40CtrlmsaRxResetTable | not-accessible | current | List of rm10010e40CtrlmsaRxReset Article |
| 1.3.6.1.4.1.20044.57.6.3.211.1 | Rowrm10010e40CtrlmsaRxResetEntry | not-accessible | current | Row definition for the rm10010e40CtrlmsaRxReset table |
| 1.3.6.1.4.1.20044.57.6.3.211.1.1 | Columnrm10010e40CtrlmsaRxResetIndex | read-only | current | Index definition for the rm10010e40CtrlmsaRxReset table |
| 1.3.6.1.4.1.20044.57.6.3.211.1.2 | Columnrm10010e40CtrlmsaRxResetPortn | read-write | current | Line MSA RX Reset :This OID resets the RX portion of the MSA line module <Help > This control initiates a reset of the receiving side |
| 1.3.6.1.4.1.20044.57.6.3.212 | Tablerm10010e40CtrlmsaShutdownTable | not-accessible | current | List of rm10010e40CtrlmsaShutdown Article |
| 1.3.6.1.4.1.20044.57.6.3.212.1 | Rowrm10010e40CtrlmsaShutdownEntry | not-accessible | current | Row definition for the rm10010e40CtrlmsaShutdown table |
| 1.3.6.1.4.1.20044.57.6.3.212.1.1 | Columnrm10010e40CtrlmsaShutdownIndex | read-only | current | Index definition for the rm10010e40CtrlmsaShutdown table |
| 1.3.6.1.4.1.20044.57.6.3.212.1.2 | Columnrm10010e40CtrlmsaShutdownPortn | read-write | current | Line MSA Shutdown :This OID enters a process to shutdown the MSA line module <Help > This control initiates a shutdown of the module |
| 1.3.6.1.4.1.20044.57.7 | Noderm10010e40ri | |||
| 1.3.6.1.4.1.20044.57.7.1 | Noderm10010e40riTable | |||
| 1.3.6.1.4.1.20044.57.7.1.1 | Tablerm10010e40RinvSfpTable | not-accessible | current | List of the SFPs on the selected module |
| 1.3.6.1.4.1.20044.57.7.1.1.1 | Rowrm10010e40RinvSfpEntry | not-accessible | current | Row definition for the SFP table |
| 1.3.6.1.4.1.20044.57.7.1.1.1.1 | Columnrm10010e40RinvSfpIndex | read-only | current | Index for SFP table |
| 1.3.6.1.4.1.20044.57.7.1.1.1.2 | Columnrm10010e40Rinvsfp | read-only | current | Inventory for the SFP: This OID contains the inventory for the SFP |
| 1.3.6.1.4.1.20044.57.7.1.2 | Tablerm10010e40RinvLineTable | not-accessible | current | List of the XFPs on the selected module |
| 1.3.6.1.4.1.20044.57.7.1.2.1 | Rowrm10010e40RinvLineEntry | not-accessible | current | Row definition for the XFP table |
| 1.3.6.1.4.1.20044.57.7.1.2.1.1 | Columnrm10010e40RinvLineIndex | read-only | current | Index for XFP table |
| 1.3.6.1.4.1.20044.57.7.1.2.1.2 | Columnrm10010e40RinvxfpLine | read-only | current | Inventory for the XFP: This OID contains the inventory for the XFP |
| 1.3.6.1.4.1.20044.57.7.2 | Scalarrm10010e40RinvReloadInventory | read-write | current | Reload the inventory: This OID triggers an inventory reload. |
| 1.3.6.1.4.1.20044.57.7.3 | Scalarrm10010e40RinvHwPlatform | read-only | current | HW platform description: This OID contains the description of the Hardware platform. |
| 1.3.6.1.4.1.20044.57.7.4 | Scalarrm10010e40RinvModulePlatform | read-only | current | Module platform description: This OID contains the description of the Module. |
| 1.3.6.1.4.1.20044.57.7.5 | Scalarrm10010e40RinvSwPlatform | read-only | current | SW platform description: This OID contains the description of the Software platform. |
| 1.3.6.1.4.1.20044.57.7.6 | Scalarrm10010e40RinvGwPlatform | read-only | current | GW platform desciption: This OID contains the description of the Gateware platform. |
| 1.3.6.1.4.1.20044.57.8 | Noderm10010e40download | |||
| 1.3.6.1.4.1.20044.57.8.1 | Noderm10010e40DwlOther | |||
| 1.3.6.1.4.1.20044.57.8.1.0 | Noderm10010e40DwlrestartProcess | |||
| 1.3.6.1.4.1.20044.57.8.1.0.1 | Scalarrm10010e40DwlWarmRestartProcessed | read-only | current | Warm Restart :This OID indicates that the module last restart was a Warm RESTART |
| 1.3.6.1.4.1.20044.57.8.1.0.2 | Scalarrm10010e40DwlColdRestartProcessed | read-only | current | Cold Restart :This OID indicates that the module last restart was a Cold RESTART |
| 1.3.6.1.4.1.20044.57.8.1.1 | Noderm10010e40DwlswBanksUsed | |||
| 1.3.6.1.4.1.20044.57.8.1.1.1 | Scalarrm10010e40DwlSwBank1Used | read-only | current | SW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.57.8.1.1.2 | Scalarrm10010e40DwlSwBank2Used | read-only | current | SW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby |
| 1.3.6.1.4.1.20044.57.8.1.1.5 | Scalarrm10010e40DwlSwBank1Notempty | read-only | current | SW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package |
| 1.3.6.1.4.1.20044.57.8.1.1.6 | Scalarrm10010e40DwlSwBank2Notempty | read-only | current | SW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package |
| 1.3.6.1.4.1.20044.57.8.1.2 | Noderm10010e40DwlgwBanksUsed | |||
| 1.3.6.1.4.1.20044.57.8.1.2.1 | Scalarrm10010e40DwlGwBank1Used | read-only | current | GW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby |
| 1.3.6.1.4.1.20044.57.8.1.2.2 | Scalarrm10010e40DwlGwBank2Used | read-only | current | GW bank 2 active :This OID indicates the module is working on GW bank 2 |
| 1.3.6.1.4.1.20044.57.8.1.2.3 | Scalarrm10010e40DwlGwBank3Used | read-only | current | GW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby |
| 1.3.6.1.4.1.20044.57.8.1.2.4 | Scalarrm10010e40DwlGwBank4Used | read-only | current | GW bank 4 active :This OID indicates the module is working on GW bank 4 |
| 1.3.6.1.4.1.20044.57.8.1.2.5 | Scalarrm10010e40DwlGwBank1Notempty | read-only | current | GW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package |
| 1.3.6.1.4.1.20044.57.8.1.2.6 | Scalarrm10010e40DwlGwBank2Notempty | read-only | current | GW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2 |
| 1.3.6.1.4.1.20044.57.8.1.2.7 | Scalarrm10010e40DwlGwBank3Notempty | read-only | current | GW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package |
| 1.3.6.1.4.1.20044.57.8.1.2.8 | Scalarrm10010e40DwlGwBank4Notempty | read-only | current | GW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4 |
| 1.3.6.1.4.1.20044.57.8.2 | Noderm10010e40DwlClient | |||
| 1.3.6.1.4.1.20044.57.8.3 | Noderm10010e40DwlLine | |||
| 1.3.6.1.4.1.20044.57.9 | Noderm10010e40Config | |||
| 1.3.6.1.4.1.20044.57.9.1 | Noderm10010e40CfgAccessCAisCsf | |||
| 1.3.6.1.4.1.20044.57.9.1.1 | Tablerm10010e40CfgClientcaiscsfTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.57.9.1.1.1 | Rowrm10010e40CfgClientcaiscsfEntry | not-accessible | current | Row definition for the accessCAisCsf table |
| 1.3.6.1.4.1.20044.57.9.1.1.1.1 | Columnrm10010e40CfgClientcaiscsfIndex | read-only | current | Index definition for the clientcaiscsf table |
| 1.3.6.1.4.1.20044.57.9.1.1.1.3 | Columnrm10010e40CfgReservePortn | read-write | current | CAIS mode on Client Port :This register enables/disables port laser shutdown on CAIS insertion condition |
| 1.3.6.1.4.1.20044.57.9.2 | Noderm10010e40CfgStartup | |||
| 1.3.6.1.4.1.20044.57.9.2.1 | Tablerm10010e40CfgClientStartupTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.57.9.2.1.1 | Rowrm10010e40CfgClientStartupEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.57.9.2.1.1.1 | Columnrm10010e40CfgClientStartupIndex | read-only | current | Index definition for the clientStartup table |
| 1.3.6.1.4.1.20044.57.9.2.1.1.3 | Columnrm10010e40CfgSystConfPortPortn | read-write | current | Default Settings on Client Port :This register configures the default initialisation settings on the port. |
| 1.3.6.1.4.1.20044.57.9.2.1.1.4 | Columnrm10010e40CfgNetConfPortPortn | read-write | current | Default Settings on Client Port :This register configures the default initialisation settings on the port. |
| 1.3.6.1.4.1.20044.57.9.2.1.1.14 | Columnrm10010e40CfgOptionsPortPortn | read-write | current | Default Options on Client Port :This register configures the default options on the port. |
| 1.3.6.1.4.1.20044.57.9.2.2 | Tablerm10010e40CfgLineStartupTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.57.9.2.2.1 | Rowrm10010e40CfgLineStartupEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.57.9.2.2.1.1 | Columnrm10010e40CfgLineStartupIndex | read-only | current | Index definition for the lineStartup table |
| 1.3.6.1.4.1.20044.57.9.2.2.1.3 | Columnrm10010e40CfgSystConfLinePortn | read-write | current | Default Settings on Line :This register configures the default initialisation settings on Line |
| 1.3.6.1.4.1.20044.57.9.2.2.1.14 | Columnrm10010e40CfgOptionsLinePortn | read-write | current | Default Options on Line :This register configures the default options on the line |
| 1.3.6.1.4.1.20044.57.9.2.3 | Tablerm10010e40CfgXfpTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.57.9.2.3.1 | Rowrm10010e40CfgXfpEntry | not-accessible | current | Row definition for the startup table |
| 1.3.6.1.4.1.20044.57.9.2.3.1.1 | Columnrm10010e40CfgXfpIndex | read-only | current | Index definition for the xfp table |
| 1.3.6.1.4.1.20044.57.9.2.3.1.3 | Columnrm10010e40CfgSystConfMsaLinePortn | read-write | current | Default settings on MSA :This register configures the default initialisation settings on MSA |
| 1.3.6.1.4.1.20044.57.9.3 | Noderm10010e40CfgLabels | |||
| 1.3.6.1.4.1.20044.57.9.3.1 | Tablerm10010e40CfgLabelclientTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.57.9.3.1.1 | Rowrm10010e40CfgLabelclientEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.57.9.3.1.1.1 | Columnrm10010e40CfgLabelclientIndex | read-only | current | Index definition for the labelclient table |
| 1.3.6.1.4.1.20044.57.9.3.1.1.3 | Columnrm10010e40CfgLabelclientPortn | read-write | current | Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. |
| 1.3.6.1.4.1.20044.57.9.3.2 | Tablerm10010e40CfgLabellineTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.57.9.3.2.1 | Rowrm10010e40CfgLabellineEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.57.9.3.2.1.1 | Columnrm10010e40CfgLabellineIndex | read-only | current | Index definition for the labelline table |
| 1.3.6.1.4.1.20044.57.9.3.2.1.3 | Columnrm10010e40CfgLabellinePortn | read-write | current | Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. |
| 1.3.6.1.4.1.20044.57.9.4 | Noderm10010e40CfgStartuptlh | |||
| 1.3.6.1.4.1.20044.57.9.4.1 | Tablerm10010e40CfgOtxtlhTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.57.9.4.1.1 | Rowrm10010e40CfgOtxtlhEntry | not-accessible | current | Row definition for the startuptlh table |
| 1.3.6.1.4.1.20044.57.9.4.1.1.1 | Columnrm10010e40CfgOtxtlhIndex | read-only | current | Index definition for the otxtlh table |
| 1.3.6.1.4.1.20044.57.9.4.1.1.6 | Columnrm10010e40CfgLinePwrLaserPortn | read-write | current | Defaut Line output Power :This register configures the start-up output power of the Line tranceiver (Unit = dBm) |
| 1.3.6.1.4.1.20044.57.9.4.1.1.7 | Columnrm10010e40CfgLineFCurrentPortn | read-write | current | Default Line transceiver Tx Channel :This register configures the start-up laser channel of the Line Tx transceiver |
| 1.3.6.1.4.1.20044.57.9.4.1.1.8 | Columnrm10010e40CfgLineGridCurrentPortn | read-write | current | Default Line transceiver Grid :This register configures the start-up laser grid of the Line transceiver |
| 1.3.6.1.4.1.20044.57.9.4.1.1.9 | Columnrm10010e40CfgFPortn | read-write | current | Default Line TRX lowest Freq :This register configures the start-up lowest frequency of the Line transceiver |
| 1.3.6.1.4.1.20044.57.9.4.1.1.10 | Columnrm10010e40CfgRxLineFCurrentPortn | read-write | current | Default Line transceiver Rx Channel :This register configures the start-up laser channel of the Line Rx transceiver |
| 1.3.6.1.4.1.20044.57.9.5 | Noderm10010e40CfgOther | |||
| 1.3.6.1.4.1.20044.57.9.5.1 | Noderm10010e40tablemoduleOther | |||
| 1.3.6.1.4.1.20044.57.9.5.1.2 | Scalarrm10010e40Cfgmode | read-write | current | Default settings on Module :This register selects the configuration mode of the module |
| 1.3.6.1.4.1.20044.57.9.5.1.3 | Scalarrm10010e40CfgfanLowSpeedThreshold | read-write | current | Default settings on Module :This register selects the speed threshold of the fan's |
| 1.3.6.1.4.1.20044.57.9.5.1.4 | Scalarrm10010e40CfgfanHighSpeedThreshold | read-write | current | Default settings on Module :This register selects the speed threshold of the fan's |
| 1.3.6.1.4.1.20044.57.9.6 | Noderm10010e40CfgStartuptablefive | |||
| 1.3.6.1.4.1.20044.57.9.6.1 | Tablerm10010e40CfgOtxtlhcapabilitiesTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.57.9.6.1.1 | Rowrm10010e40CfgOtxtlhcapabilitiesEntry | not-accessible | current | Row definition for the startuptablefive table |
| 1.3.6.1.4.1.20044.57.9.6.1.1.1 | Columnrm10010e40CfgOtxtlhcapabilitiesIndex | read-only | current | Index definition for the otxtlhcapabilities table |
| 1.3.6.1.4.1.20044.57.9.6.1.1.3 | Columnrm10010e40CfgComponentTypePortn | read-only | current | Component parameters :This OID defines the component parameters |
| 1.3.6.1.4.1.20044.57.9.6.1.1.4 | Columnrm10010e40CfgMiscellaneousPortn | read-only | current | Miscellaneous default settings :This OID defines the miscellaneous parameters |
| 1.3.6.1.4.1.20044.57.9.6.1.1.5 | Columnrm10010e40CfgFirstChannelPortn | read-only | current | Number of the first channel of the component :This OID defines the first channel number of the PM |
| 1.3.6.1.4.1.20044.57.9.6.1.1.6 | Columnrm10010e40CfgLastChannelPortn | read-only | current | Number of the last channel of the component :This OID defines the last channel number of the PM |
| 1.3.6.1.4.1.20044.57.9.6.1.1.7 | Columnrm10010e40CfgGridPortn | read-only | current | Grid value of the component :This OID defines the grid of the PM |
| 1.3.6.1.4.1.20044.57.9.257 | Scalarrm10010e40CfgWriteConfiguration | read-write | current | Write configuration to module:This OID writes the complete configuration to the module |
| 1.3.6.1.4.1.20044.57.10 | Noderm10010e40traps | |||
| 1.3.6.1.4.1.20044.57.10.2 | Scalarrm10010e40trapPortNumber | read-only | current | Last port which generates a trap |
| 1.3.6.1.4.1.20044.57.10.3 | Scalarrm10010e40trapLineNumber | read-only | current | Last Line which generates a trap |
| 1.3.6.1.4.1.20044.57.10.4 | Scalarrm10010e40trapBoardNumber | read-only | current | Last module which generates a trap |
| 1.3.6.1.4.1.20044.57.10.30 | Notificationrm10010e40LineTrapNotUrgentGoesOn | current | Not urgent Line default is activated | |
| 1.3.6.1.4.1.20044.57.10.31 | Notificationrm10010e40LineTrapNotUrgentGoesOff | current | Not urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.57.10.32 | Notificationrm10010e40LineTrapUrgentGoesOn | current | Urgent Line default is activated | |
| 1.3.6.1.4.1.20044.57.10.33 | Notificationrm10010e40LineTrapUrgentGoesOff | current | Urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.57.10.34 | Notificationrm10010e40LineTrapCritGoesOn | current | Critical Line default is activated | |
| 1.3.6.1.4.1.20044.57.10.35 | Notificationrm10010e40LineTrapCritGoesOff | current | Critical Line default disappeared | |
| 1.3.6.1.4.1.20044.57.10.40 | Notificationrm10010e40ClientTrapNotUrgentGoesOn | current | Not urgent client default is activated | |
| 1.3.6.1.4.1.20044.57.10.41 | Notificationrm10010e40ClientTrapNotUrgentGoesOff | current | Not urgent client default disappeared | |
| 1.3.6.1.4.1.20044.57.10.42 | Notificationrm10010e40ClientTrapUrgentGoesOn | current | Urgent client default is activated | |
| 1.3.6.1.4.1.20044.57.10.43 | Notificationrm10010e40ClientTrapUrgentGoesOff | current | Urgent client default disappeared | |
| 1.3.6.1.4.1.20044.57.10.44 | Notificationrm10010e40ClientTrapCritGoesOn | current | Critical client default is activated | |
| 1.3.6.1.4.1.20044.57.10.45 | Notificationrm10010e40ClientTrapCritGoesOff | current | Critical client default disappeared | |
| 1.3.6.1.4.1.20044.57.10.50 | Notificationrm10010e40PowerTrapUrgentGoesOn | current | Urgent power supply default is activated | |
| 1.3.6.1.4.1.20044.57.10.51 | Notificationrm10010e40PowerTrapUrgentGoesOff | current | Urgent power supply default disappeared | |
| 1.3.6.1.4.1.20044.57.11 | Noderm10010e40Monitoring | |||
| 1.3.6.1.4.1.20044.57.11.1 | Noderm10010e40MonOther | |||
| 1.3.6.1.4.1.20044.57.11.1.3 | Noderm10010e40MonRmon | |||
| 1.3.6.1.4.1.20044.57.11.2 | Noderm10010e40MonClient | |||
| 1.3.6.1.4.1.20044.57.11.2.4 | Noderm10010e40MonClientRmonCounter | |||
| 1.3.6.1.4.1.20044.57.11.2.4.16 | Tablerm10010e40MonupRmonBytesCounterClientInputTable | not-accessible | current | List of rm10010e40MonupRmonBytesCounterClientInput Article |
| 1.3.6.1.4.1.20044.57.11.2.4.16.1 | Rowrm10010e40MonupRmonBytesCounterClientInputEntry | not-accessible | current | Row definition for the rm10010e40MonupRmonBytesCounterClientInput table |
| 1.3.6.1.4.1.20044.57.11.2.4.16.1.1 | Columnrm10010e40MonupRmonBytesCounterClientInputIndex | read-only | current | Index definition for the rm10010e40MonupRmonBytesCounterClientInput table |
| 1.3.6.1.4.1.20044.57.11.2.4.16.1.2 | Columnrm10010e40MonupRmonBytesCounterClientInputValuePortn | read-only | current | Client Input Bytes :This counter is increased each time a data byte is received on the client port <Help> This counter gives the number of bytes received on th… |
| 1.3.6.1.4.1.20044.57.11.2.4.16.1.3 | Columnrm10010e40MonupRmonBytesCounterClientInputErrorPortn | read-only | current | Bytes Counter Error :This OID when set indicates the Bytes counter value is invalid on client port |
| 1.3.6.1.4.1.20044.57.11.2.4.16.1.4 | Columnrm10010e40MonupRmonBytesCounterClientInputOverloadPortn | read-only | current | Bytes Counter Overload :This OID when set indicates a Bytes counter overload on client port |
| 1.3.6.1.4.1.20044.57.11.2.4.32 | Tablerm10010e40MonupRmonCrcErrorsCounterClientInputTable | not-accessible | current | List of rm10010e40MonupRmonCrcErrorsCounterClientInput Article |
| 1.3.6.1.4.1.20044.57.11.2.4.32.1 | Rowrm10010e40MonupRmonCrcErrorsCounterClientInputEntry | not-accessible | current | Row definition for the rm10010e40MonupRmonCrcErrorsCounterClientInput table |
| 1.3.6.1.4.1.20044.57.11.2.4.32.1.1 | Columnrm10010e40MonupRmonCrcErrorsCounterClientInputIndex | read-only | current | Index definition for the rm10010e40MonupRmonCrcErrorsCounterClientInput table |
| 1.3.6.1.4.1.20044.57.11.2.4.32.1.2 | Columnrm10010e40MonupRmonCrcErrorsCounterClientInputValuePortn | read-only | current | Client Input CRC Errors :This counter is increased each time a B1/CRC error is detected on the client port <Help> This counter gives the number of B1/CRC Error… |
| 1.3.6.1.4.1.20044.57.11.2.4.32.1.3 | Columnrm10010e40MonupRmonCrcErrorsCounterClientInputErrorPortn | read-only | current | CRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on client port |
| 1.3.6.1.4.1.20044.57.11.2.4.32.1.4 | Columnrm10010e40MonupRmonCrcErrorsCounterClientInputOverloadPortn | read-only | current | CRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on client port |
| 1.3.6.1.4.1.20044.57.11.2.4.48 | Tablerm10010e40MonupRmonPacketsCounterClientInputTable | not-accessible | current | List of rm10010e40MonupRmonPacketsCounterClientInput Article |
| 1.3.6.1.4.1.20044.57.11.2.4.48.1 | Rowrm10010e40MonupRmonPacketsCounterClientInputEntry | not-accessible | current | Row definition for the rm10010e40MonupRmonPacketsCounterClientInput table |
| 1.3.6.1.4.1.20044.57.11.2.4.48.1.1 | Columnrm10010e40MonupRmonPacketsCounterClientInputIndex | read-only | current | Index definition for the rm10010e40MonupRmonPacketsCounterClientInput table |
| 1.3.6.1.4.1.20044.57.11.2.4.48.1.2 | Columnrm10010e40MonupRmonPacketsCounterClientInputValuePortn | read-only | current | Client Input Packets :This counter is increased each time a packet is received on the client port <Help> This counter gives the number of packets received on t… |
| 1.3.6.1.4.1.20044.57.11.2.4.48.1.3 | Columnrm10010e40MonupRmonPacketsCounterClientInputErrorPortn | read-only | current | Packets Counter Error :This OID when set indicates the Packets counter value is invalid on client port |
| 1.3.6.1.4.1.20044.57.11.2.4.48.1.4 | Columnrm10010e40MonupRmonPacketsCounterClientInputOverloadPortn | read-only | current | Packets Counter Overload :This OID when set indicates a Packets counter overload on client port |
| 1.3.6.1.4.1.20044.57.11.2.4.64 | Tablerm10010e40MonupRmonBroadcastCounterClientInputTable | not-accessible | current | List of rm10010e40MonupRmonBroadcastCounterClientInput Article |
| 1.3.6.1.4.1.20044.57.11.2.4.64.1 | Rowrm10010e40MonupRmonBroadcastCounterClientInputEntry | not-accessible | current | Row definition for the rm10010e40MonupRmonBroadcastCounterClientInput table |
| 1.3.6.1.4.1.20044.57.11.2.4.64.1.1 | Columnrm10010e40MonupRmonBroadcastCounterClientInputIndex | read-only | current | Index definition for the rm10010e40MonupRmonBroadcastCounterClientInput table |
| 1.3.6.1.4.1.20044.57.11.2.4.64.1.2 | Columnrm10010e40MonupRmonBroadcastCounterClientInputValuePortn | read-only | current | Client Input Broadcast Packets :This counter is increased each time a broadcast packet is received on the client port <Help> This counter gives the number of B… |
| 1.3.6.1.4.1.20044.57.11.2.4.64.1.3 | Columnrm10010e40MonupRmonBroadcastCounterClientInputErrorPortn | read-only | current | Broadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.57.11.2.4.64.1.4 | Columnrm10010e40MonupRmonBroadcastCounterClientInputOverloadPortn | read-only | current | Broadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port |
| 1.3.6.1.4.1.20044.57.11.2.4.80 | Tablerm10010e40MonupRmonMulticastCounterClientInputTable | not-accessible | current | List of rm10010e40MonupRmonMulticastCounterClientInput Article |
| 1.3.6.1.4.1.20044.57.11.2.4.80.1 | Rowrm10010e40MonupRmonMulticastCounterClientInputEntry | not-accessible | current | Row definition for the rm10010e40MonupRmonMulticastCounterClientInput table |
| 1.3.6.1.4.1.20044.57.11.2.4.80.1.1 | Columnrm10010e40MonupRmonMulticastCounterClientInputIndex | read-only | current | Index definition for the rm10010e40MonupRmonMulticastCounterClientInput table |
| 1.3.6.1.4.1.20044.57.11.2.4.80.1.2 | Columnrm10010e40MonupRmonMulticastCounterClientInputValuePortn | read-only | current | Client Input Multicast Packets :This counter is increased each time a Multicast packet is received on the client port <Help> This counter gives the number of M… |
| 1.3.6.1.4.1.20044.57.11.2.4.80.1.3 | Columnrm10010e40MonupRmonMulticastCounterClientInputErrorPortn | read-only | current | Multicast Counter Error :This OID when set indicates the Multicast counter value is invalid on client port |
| 1.3.6.1.4.1.20044.57.11.2.4.80.1.4 | Columnrm10010e40MonupRmonMulticastCounterClientInputOverloadPortn | read-only | current | Multicast Counter Overload :This OID when set indicates a Multicast counter overload on client port |
| 1.3.6.1.4.1.20044.57.11.2.4.96 | Tablerm10010e40MonupRmonPauseFrameCounterClientInputTable | not-accessible | current | List of rm10010e40MonupRmonPauseFrameCounterClientInput Article |
| 1.3.6.1.4.1.20044.57.11.2.4.96.1 | Rowrm10010e40MonupRmonPauseFrameCounterClientInputEntry | not-accessible | current | Row definition for the rm10010e40MonupRmonPauseFrameCounterClientInput table |
| 1.3.6.1.4.1.20044.57.11.2.4.96.1.1 | Columnrm10010e40MonupRmonPauseFrameCounterClientInputIndex | read-only | current | Index definition for the rm10010e40MonupRmonPauseFrameCounterClientInput table |
| 1.3.6.1.4.1.20044.57.11.2.4.96.1.2 | Columnrm10010e40MonupRmonPauseFrameCounterClientInputValuePortn | read-only | current | Client Input Pause Frames :This counter is increased each time a Pause frame is received on the client port <Help> This counter gives the number of Pause frame… |
| 1.3.6.1.4.1.20044.57.11.2.4.96.1.3 | Columnrm10010e40MonupRmonPauseFrameCounterClientInputErrorPortn | read-only | current | Pause Counter Error :This OID when set indicates the Pause counter value is invalid on client port |
| 1.3.6.1.4.1.20044.57.11.2.4.96.1.4 | Columnrm10010e40MonupRmonPauseFrameCounterClientInputOverloadPortn | read-only | current | Pause Counter Overload :This OID when set indicates a Pause counter overload on client port |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| Rm10010e40AdjustValue | INTEGER { otxadjustvalue0(0), otxadjustvalue1(1), otxadjustvalue2(2), otxadjustvalue3(3), otxadjustvalue4(4), otxadjustvalue5(5), otxadjustvalue6(6), otxadjustvalue7(7), otxadjustvalue8(8), otxadjustvalue9(9), otxadjustvalue10(10) } | current | Different values in Adjust mode on OTX-TLH on client and line ports |
| Rm10010e40ClientProtocol | INTEGER { protocolclientvalue0(0), protocolclientvalue1(1), protocolclientvalue2(2), protocolclientvalue3(3), protocolclientvalue4(4), protocolclientvalue5(5), protocolclientvalue6(6), protocolclientvalue7(7), protocolclientvalue8(8) } | current | Different values on the protocol on the client ports |
| Rm10010e40MultiRate | INTEGER { rate100Mhz(0), rate250Mhz(1), rate500Mhz(2), rate1Ghz(3) } | current | different rate for a client port |
| Rm10010e40OrxChannel | INTEGER | current | Channel selection on transceiver Rx line ports |
| Rm10010e40OtxChannel | INTEGER | current | Channel selection on transceiver Tx line ports |
| Rm10010e40OtxGrid | INTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50) } | current | Different grids on OTX-TLH on client and line ports |
| Rm10010e40OtxMode | INTEGER { otx80mode(1), otx60mode(2), otxadjustmode(4) } | current | Different modes on OTX-TLH on client and line ports |
| Rm10010e40ProtocolMode | INTEGER { protocolmodevalue0(0), protocolmodevalue1(1), protocolmodevalue2(2), protocolmodevalue3(3) } | current | Different values on the protocol mode |