MIB Viewer

EKINOPS-Rm10010mp-MIB

703 objects
Creation.
OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.54IdentitymoduleRm10010mpCreation.
1.3.6.1.4.1.20044.54.2Noderm10010mpalarms
1.3.6.1.4.1.20044.54.2.1Noderm10010mpAlmOther
1.3.6.1.4.1.20044.54.2.1.1Noderm10010mpAlmOtherNurg
1.3.6.1.4.1.20044.54.2.1.1.2Noderm10010mpAlmsynthAlm2
1.3.6.1.4.1.20044.54.2.1.1.2.1Scalarrm10010mpAlmConfTableSaveread-onlycurrentPM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> infor…
1.3.6.1.4.1.20044.54.2.1.1.2.2Scalarrm10010mpAlmInvUploadread-onlycurrentInventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> informationalStatus(1000) <Alarmtype> ot…
1.3.6.1.4.1.20044.54.2.1.1.2.3Scalarrm10010mpAlmConfTableLoadread-onlycurrentPM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> informationalStat…
1.3.6.1.4.1.20044.54.2.1.1.2.4Scalarrm10010mpAlmCorrelatOffread-onlycurrentNot Used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> informationalStatus(1000) <Alarmtype…
1.3.6.1.4.1.20044.54.2.1.1.2.5Scalarrm10010mpAlmMaintenanceOnread-onlycurrentMaintenance Mode :This OID indicates that the RM is in maintenance mode. <Help> This alarm indicates that the maintenance mode is enabled on the PM <Condtype> …
1.3.6.1.4.1.20044.54.2.1.2Noderm10010mpAlmOtherUrg
1.3.6.1.4.1.20044.54.2.1.2.248Noderm10010mpAlmmodFanFail
1.3.6.1.4.1.20044.54.2.1.2.248.1Scalarrm10010mpAlmFanModuleAbsentread-onlycurrentFan Module Absent :This OID indicates the presence of the FAN module in the Chassis. <Help> This alarm indicates if the FAN module is detected in the chassis. …
1.3.6.1.4.1.20044.54.2.1.2.248.2Scalarrm10010mpAlmFansFailread-onlycurrentFan Module Failure :This OID indicates that at least one of the 4 FAN unit of the FAN module is in fail condition <Help> This alarm indicates if one the FANs i…
1.3.6.1.4.1.20044.54.2.1.2.248.4Scalarrm10010mpAlmFan1Failread-onlycurrentFan Unit N�1 Failed On Fan Module :This OID indicates a failure on fan 1. Removal of the fan unit or no rotation sets the OID. <Help> This alarm indicates if…
1.3.6.1.4.1.20044.54.2.1.2.248.5Scalarrm10010mpAlmFan2Failread-onlycurrentFan Unit N�2 Failed On Fan Module :This OID indicates a failure on fan 2. Removal of the fan unit or no rotation sets the OID. <Help> This alarm indicates if…
1.3.6.1.4.1.20044.54.2.1.2.248.6Scalarrm10010mpAlmFan3Failread-onlycurrentFan Unit N�3 Failed On Fan Module :This OID indicates a failure on fan 3. Removal of the fan unit or no rotation sets the OID. <Help> This alarm indicates if…
1.3.6.1.4.1.20044.54.2.1.2.248.7Scalarrm10010mpAlmFan4Failread-onlycurrentFan Unit N�4 Failed On Fan Module :This OID indicates a failure on fan 4. Removal of the fan unit or no rotation sets the OID. <Help> This alarm indicates if…
1.3.6.1.4.1.20044.54.2.1.3Noderm10010mpAlmOtherCrit
1.3.6.1.4.1.20044.54.2.1.3.0Noderm10010mpAlmsynthAlm0
1.3.6.1.4.1.20044.54.2.1.3.0.2Scalarrm10010mpAlmFailFanread-onlycurrentFan Fail :This OID is at 1 when any fail occurs on the fan tray <Help> This alarm indicates that the Fan tray module is in a failure condition <Condtype> FAIL_…
1.3.6.1.4.1.20044.54.2.1.3.0.9Scalarrm10010mpAlmModGlobFailread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the RM <Help> This alarm is set on detection of a failure originating from the equip…
1.3.6.1.4.1.20044.54.2.1.3.0.15Scalarrm10010mpAlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.54.2.1.3.0.16Scalarrm10010mpAlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.54.2.1.3.40Noderm10010mpAlmclientModuleState
1.3.6.1.4.1.20044.54.2.1.3.40.1Scalarrm10010mpAlmCfpInitializeread-onlycurrentClient Trscv Initialize :This OID indicates the Client Trscv initialization is in progress <Help> Status indicating the Client Trscv initialization is in progr…
1.3.6.1.4.1.20044.54.2.1.3.40.2Scalarrm10010mpAlmCfpLowPowerread-onlycurrentClient Trscv Low Power :This OID indicates the Client Trscv is in low power state <Help> Status indicating the Client Trscv is in low power state <Condtype> CF…
1.3.6.1.4.1.20044.54.2.1.3.40.3Scalarrm10010mpAlmCfpHighPowerUpread-onlycurrentClient Trscv High Power Up :This OID indicates the Client Trscv is leaving Low Power state <Help> Status indicating the Client Trscv is leaving Low Power state…
1.3.6.1.4.1.20044.54.2.1.3.40.4Scalarrm10010mpAlmCfpTxOffread-onlycurrentClient Trscv Laser Shutdown :This OID indicates the Client Trscv Laser is OFF <Help> Status indicating the Client Trscv Laser is OFF <Condtype> CFP_TX_OFF <Pro…
1.3.6.1.4.1.20044.54.2.1.3.40.5Scalarrm10010mpAlmCfpTxTurnOnread-onlycurrentClient Trscv Laser Turn On :This OID indicates the Client Trscv is turning on its laser <Help> Status indicating the Client Trscv is turning on its laser <Cond…
1.3.6.1.4.1.20044.54.2.1.3.40.6Scalarrm10010mpAlmCfpReadyread-onlycurrentClient Trscv Ready :This OID indicates the Client Trscv is ready to operate <Help> Status indicating the Client Trscv is ready to operate <Condtype> CFP_READY …
1.3.6.1.4.1.20044.54.2.1.3.40.7Scalarrm10010mpAlmCfpFaultread-onlycurrentClient Trscv Fault :This OID indicates the Client Trscv is in Fault state <Help> Status indicating the Client Trscv is in Fault state <Condtype> CFP_FAULT <Pro…
1.3.6.1.4.1.20044.54.2.1.3.40.8Scalarrm10010mpAlmCfpTxTurnOffread-onlycurrentClient Trscv Laser Turn Off :This OID indicates the Client Trscv is turning off its laser <Help> Status indicating the Client Trscv is turning off its laser <C…
1.3.6.1.4.1.20044.54.2.1.3.40.9Scalarrm10010mpAlmCfpHighPowerDownread-onlycurrentClient Trscv High Power Down :This OID indicates the Client Trscv is entering Low Power state <Help> Status indicating the Client Trscv is entering Low Power s…
1.3.6.1.4.1.20044.54.2.1.3.41Noderm10010mpAlmclientModuleGeneralStatus
1.3.6.1.4.1.20044.54.2.1.3.41.4Scalarrm10010mpAlmCfpOutOfAlignmentread-onlycurrentClient Trscv Out Of Alignment :This OID indicates an Out of alignment on the Client Trscv Host Interface <Help> Alarm indicating an Out of alignment on the Cli…
1.3.6.1.4.1.20044.54.2.1.3.41.5Scalarrm10010mpAlmCfpRxNetworkLolread-onlycurrentClient Trscv Rx Network Loss Of Lock :This OID indicates of Loss of Lock is dected on the Client Trscv Rx Network interface <Help> Alarm indicating of Loss of …
1.3.6.1.4.1.20044.54.2.1.3.41.6Scalarrm10010mpAlmCfpRxLosread-onlycurrentClient Trscv Loss Of Signal :This OID indicates a Loss of Signal is detected on the Client Trscv <Help> Alarm indicating a Loss of Signal is detected on the Cl…
1.3.6.1.4.1.20044.54.2.1.3.41.7Scalarrm10010mpAlmCfpTxHostLolread-onlycurrentClient Trscv Tx Host Loss Of Lock :This OID indicates of Loss of Lock is detected on the Client Trscv Tx Host interface <Help> Alarm indicating of Loss of Lock…
1.3.6.1.4.1.20044.54.2.1.3.41.8Scalarrm10010mpAlmCfpTxLosfread-onlycurrentClient Trscv Loss Of Signal Functionality :This OID indicates a Loss of Signal functionality is detected on the Client Trscv <Help> Alarm indicating a Loss of …
1.3.6.1.4.1.20044.54.2.1.3.41.9Scalarrm10010mpAlmCfpTxCmuLolread-onlycurrentClient Trscv CMU Loss Of Lock :This OID indicates a Clock Multiplier Unit Loss of Lock is detected on the Client Trscv <Help> Alarm indicating a Clock Multipli…
1.3.6.1.4.1.20044.54.2.1.3.41.10Scalarrm10010mpAlmCfpTxJitterPllLolread-onlycurrentClient Trscv Tx Jitter PLL Loss Of Lock :This OID indicates a Tx Jitter PLL Loss of Lock is dtected on the Client Trscv <Help> Alarm indicating a Tx Jitter PLL…
1.3.6.1.4.1.20044.54.2.1.3.41.11Scalarrm10010mpAlmCfpLossOfRefclkread-onlycurrentClient Trscv Loss Of Ref Clock :This OID indicates a Loss of Reference clock is detected on the Client Trscv <Help> Alarm indicating a Loss of Reference clock …
1.3.6.1.4.1.20044.54.2.1.3.41.14Scalarrm10010mpAlmCfpHwInterlockread-onlycurrentClient Trscv Hardware Interlock :This OID indicates the Client Trscv power is higher than the cooling capacity <Help> Alarm indicating the Client Trscv power i…
1.3.6.1.4.1.20044.54.2.1.3.42Noderm10010mpAlmclientGlobalAlarmSummary
1.3.6.1.4.1.20044.54.2.1.3.42.1Scalarrm10010mpAlmCfpSoftGlobAlarmTestread-onlycurrentClient Trscv Global Alarm SW Test :This OID indicates the Client Trscv Global Alarm This OID is raised by SW request for test purpose <Help> Status indicating …
1.3.6.1.4.1.20044.54.2.1.3.42.7Scalarrm10010mpAlmCfpNetworkLaneAlarmWarning2read-onlycurrentClient Trscv Network Alarm And Warning 2 :This OID indicates at least one DDM is detected on the Client Trscv Network Interface <Help> Synthesis alarm indicati…
1.3.6.1.4.1.20044.54.2.1.3.42.8Scalarrm10010mpAlmCfpModuleStateread-onlycurrentClient Trscv Module State :This OID indicates the Client Trscv module state <Help> Synthesis alarm indicating the Client Trscv module state <Condtype> CFP_MODU…
1.3.6.1.4.1.20044.54.2.1.3.42.9Scalarrm10010mpAlmCfpModuleGeneralStatusread-onlycurrentClient Trscv General Status :This OID indicates the Client Trscv module general status <Help> Synthesis alarm indicating the Client Trscv module general status…
1.3.6.1.4.1.20044.54.2.1.3.42.10Scalarrm10010mpAlmCfpModuleFaultread-onlycurrentClient Trscv Module Fault :This OID indicates at least one Fault is detected on the Client Trscv module <Help> Synthesis alarm indicating at least one Fault is…
1.3.6.1.4.1.20044.54.2.1.3.42.11Scalarrm10010mpAlmCfpModuleAlarmWarning1read-onlycurrentClient Trscv Module Alarm And Warning 1 :This OID indicates at least one DDM This OID is detected on the Client Trscv module <Help> Synthesis alarm indicating …
1.3.6.1.4.1.20044.54.2.1.3.42.12Scalarrm10010mpAlmCfpModuleAlarmWarning2read-onlycurrentClient Trscv Module Alarm And Warning 2 :This OID indicates at least one DDM is detected on the Client Trscv module <Help> Synthesis alarm indicating at least …
1.3.6.1.4.1.20044.54.2.1.3.42.13Scalarrm10010mpAlmCfpNetworkLaneAlarmWarning1read-onlycurrentClient Trscv Network Alarm And Warning 1 :This OID indicates at least one DDM is detected on the Client Trscv Network Interface <Help> Synthesis alarm indicati…
1.3.6.1.4.1.20044.54.2.1.3.42.14Scalarrm10010mpAlmCfpNetworkLaneFaultStatusread-onlycurrentClient Trscv Network Fault And Status :This OID indicates at least one Fault or Status is detected on the Client Trscv Network Interface <Help> Synthesis alarm…
1.3.6.1.4.1.20044.54.2.1.3.42.15Scalarrm10010mpAlmCfpHostLaneFaultStatusread-onlycurrentClient Trscv Host Fault And Status :This OID indicates at least one Fault or Status is detected on the Client Trscv Host Interface <Help> Synthesis alarm indic…
1.3.6.1.4.1.20044.54.2.1.3.42.16Scalarrm10010mpAlmCfpGlobAlarmAssertionread-onlycurrentClient Trscv Global Alarm :This OID indicates at least one Fault or Status is detected on the Client Trscv module <Help> Synthesis alarm indicating at least on…
1.3.6.1.4.1.20044.54.2.1.3.46Noderm10010mpAlmmsaModuleState
1.3.6.1.4.1.20044.54.2.1.3.46.1Scalarrm10010mpAlmMsaInitializeread-onlycurrentLine Trscv Initialize :This OID indicates the Line Trscv initialization is in progress <Help> Status indicating the Line Trscv initialization is in progress <C…
1.3.6.1.4.1.20044.54.2.1.3.46.2Scalarrm10010mpAlmMsaLowPowerread-onlycurrentLine Trscv Low Power :This OID indicates the Line Trscv is in low power state <Help> Status indicating the Line Trscv is in low power state <Condtype> MSA_LOW_…
1.3.6.1.4.1.20044.54.2.1.3.46.3Scalarrm10010mpAlmMsaHighPowerUpread-onlycurrentLine Trscv High Power Up :This OID indicates the Line Trscv is leaving Low Power state <Help> Status indicating the Line Trscv is leaving Low Power state <Cond…
1.3.6.1.4.1.20044.54.2.1.3.46.4Scalarrm10010mpAlmMsaTxOffread-onlycurrentLine Trscv Laser Shutdown :This OID indicates the Line Trscv Laser is OFF <Help> Status indicating the Line Trscv Laser is OFF <Condtype> MSA_TX_OFF <Probcause…
1.3.6.1.4.1.20044.54.2.1.3.46.5Scalarrm10010mpAlmMsaTxTurnOnread-onlycurrentLine Trscv Laser Turn On :This OID indicates the Line Trscv is turning on its laser <Help> Status indicating the Line Trscv is turning on its laser <Condtype> …
1.3.6.1.4.1.20044.54.2.1.3.46.6Scalarrm10010mpAlmMsaReadyread-onlycurrentLine Trscv Ready :This OID indicates the Line Trscv is ready to operate <Help> Status indicating the Line Trscv is ready to operate <Condtype> MSA_READY <Probc…
1.3.6.1.4.1.20044.54.2.1.3.46.7Scalarrm10010mpAlmMsaFaultread-onlycurrentLine Trscv Fault :This OID indicates the Line Trscv is in Fault state <Help> Status indicating the Line Trscv is in Fault state <Condtype> MSA_FAULT <Probcause…
1.3.6.1.4.1.20044.54.2.1.3.46.8Scalarrm10010mpAlmMsaTxTurnOffread-onlycurrentLine Trscv Laser Turn Off :This OID indicates the Line Trscv is turning off its laser <Help> Status indicating the Line Trscv is turning off its laser <Condtyp…
1.3.6.1.4.1.20044.54.2.1.3.46.9Scalarrm10010mpAlmMsaHighPowerDownread-onlycurrentLine Trscv High Power Down :This OID indicates the Line Trscv is entering Low Power state <Help> Status indicating the Line Trscv is entering Low Power state <…
1.3.6.1.4.1.20044.54.2.1.3.47Noderm10010mpAlmmsaModuleGeneralStatus
1.3.6.1.4.1.20044.54.2.1.3.47.4Scalarrm10010mpAlmMsaOutOfAlignmentread-onlycurrentLine Trscv Out Of Alignment :This OID indicates an Out of alignment on the Line Trscv Host Interface <Help> Alarm indicating an Out of alignment on the Line Tr…
1.3.6.1.4.1.20044.54.2.1.3.47.5Scalarrm10010mpAlmMsaRxNetworkLolread-onlycurrentLine Trscv Rx Network Loss Of Lock :This OID indicates of Loss of Lock is detected on the Line Trscv Rx Network interface <Help> Alarm indicating of Loss of Lo…
1.3.6.1.4.1.20044.54.2.1.3.47.6Scalarrm10010mpAlmMsaRxLosread-onlycurrentLine Trscv Loss Of Signal :This OID indicates a Loss of Signal is detected on the Line Trscv <Help> Alarm indicating a Loss of Signal is detected on the Line T…
1.3.6.1.4.1.20044.54.2.1.3.47.7Scalarrm10010mpAlmMsaTxHostLolread-onlycurrentLine Trscv Tx Host Loss Of Lock :This OID indicates of Loss of Lock is detected on the Line Trscv Tx Host interface <Help> Alarm indicating of Loss of Lock is …
1.3.6.1.4.1.20044.54.2.1.3.47.8Scalarrm10010mpAlmMsaTxLosfread-onlycurrentLine Trscv Loss Of Signal Functionality :This OID indicates a Loss of Signal functionality is detected on the Line Trscv <Help> Alarm indicating a Loss of Sign…
1.3.6.1.4.1.20044.54.2.1.3.47.9Scalarrm10010mpAlmMsaTxCmuLolread-onlycurrentLine Trscv CMU Loss Of Lock :This OID indicates a Clock Multiplier Unit Loss of Lock is detected on the Line Trscv <Help> Alarm indicating a Clock Multiplier U…
1.3.6.1.4.1.20044.54.2.1.3.47.10Scalarrm10010mpAlmMsaTxJitterPllLolread-onlycurrentLine Trscv Tx Jitter PLL Loss Of Lock :This OID indicates a Tx Jitter PLL Loss of Lock is detected on the Line Trscv <Help> Alarm indicating a Tx Jitter PLL Lo…
1.3.6.1.4.1.20044.54.2.1.3.47.11Scalarrm10010mpAlmMsaLossOfRefclkread-onlycurrentLine Trscv Loss Of Ref Clock :This OID indicates a Loss of Reference clock is detected on the Line Trscv <Help> Alarm indicating a Loss of Reference clock is d…
1.3.6.1.4.1.20044.54.2.1.3.47.14Scalarrm10010mpAlmMsaHwInterlockread-onlycurrentLine Trscv Hardware Interlock :This OID indicates the Line Trscv power is higher than the cooling capacity <Help> Alarm indicating the Line Trscv power is high…
1.3.6.1.4.1.20044.54.2.1.3.48Noderm10010mpAlmmsaGlobalAlarmSummary
1.3.6.1.4.1.20044.54.2.1.3.48.1Scalarrm10010mpAlmMsaSoftGlobAlarmTestread-onlycurrentLine Trscv Global Alarm SW Test :This OID indicates the Line Trscv Global alarm This OID is raised by SW request for test purpose <Help> Status indicating the …
1.3.6.1.4.1.20044.54.2.1.3.48.6Scalarrm10010mpAlmMsaNetworkHostAlarmStatusread-onlycurrentLine Trscv Network/Host Alarm Status :This OID indicates the state of the Network and Host interface of the Line Trscv <Help> Synthesis alarm indicating the al…
1.3.6.1.4.1.20044.54.2.1.3.48.7Scalarrm10010mpAlmMsaNetworkLaneAlarmWarning2read-onlycurrentLine Trscv Network Alarm And Warning 2 :This OID indicates at least one DDM This OID is detected on the Line Trscv Network Interface <Help> Synthesis alarm ind…
1.3.6.1.4.1.20044.54.2.1.3.48.8Scalarrm10010mpAlmMsaModuleStateread-onlycurrentLine Trscv Module State :This OID indicates the Line Trscv module state <Help> Synthesis alarm indicating the Line Trscv module state <Condtype> MSA_MODULE_STA…
1.3.6.1.4.1.20044.54.2.1.3.48.9Scalarrm10010mpAlmMsaModuleGeneralStatusread-onlycurrentLine Trscv General Status :This OID indicates the Line Trscv module general <Help> Synthesis alarm indicating the Line Trscv module general status <Condtype> M…
1.3.6.1.4.1.20044.54.2.1.3.48.10Scalarrm10010mpAlmModuleFaultread-onlycurrentLine Trscv Module Fault :This OID indicates at least one Fault is detected on the Line Trscv module <Help> Synthesis alarm indicating at least one Fault is det…
1.3.6.1.4.1.20044.54.2.1.3.48.11Scalarrm10010mpAlmMsaModuleAlarmWarning1read-onlycurrentLine Trscv Module Alarm And Warning 1 :This OID indicates at least one DDM is detected on the Line Trscv module <Help> Synthesis alarm indicating at least one …
1.3.6.1.4.1.20044.54.2.1.3.48.12Scalarrm10010mpAlmMsaModuleAlarmWarning2read-onlycurrentLine Trscv Module Alarm And Warning 2 :This OID indicates at least one DDM is detected on the Line Trscv module <Help> Synthesis alarm indicating at least one …
1.3.6.1.4.1.20044.54.2.1.3.48.13Scalarrm10010mpAlmMsaNetworkLaneAlarmWarning1read-onlycurrentLine Trscv Network Alarm And Warning 1 :This OID indicates at least one DDM is detected on the Line Trscv Network Interface <Help> Synthesis alarm indicating a…
1.3.6.1.4.1.20044.54.2.1.3.48.14Scalarrm10010mpAlmMsaNetworkLaneFaultStatusread-onlycurrentLine Trscv Network Fault And Status :This OID indicates at least one Fault or Status is detected on the Line Trscv Network Interface <Help> Synthesis alarm ind…
1.3.6.1.4.1.20044.54.2.1.3.48.15Scalarrm10010mpAlmMsaHostLaneFaultStatusread-onlycurrentLine Trscv Host Fault And Status :This OID indicates at least one Fault or Status is detected on the Line Trscv Host Interface <Help> Synthesis alarm indicatin…
1.3.6.1.4.1.20044.54.2.1.3.48.16Scalarrm10010mpAlmMsaGlobAlarmAssertionread-onlycurrentLine Trscv Global Alarm :This OID indicates at least one Fault or Status is detected on the Line Trscv module <Help> Synthesis alarm indicating at least one Al…
1.3.6.1.4.1.20044.54.2.1.3.49Noderm10010mpAlmmsaNetworkTxAlignment
1.3.6.1.4.1.20044.54.2.1.3.49.12Scalarrm10010mpAlmNetTxTimingFaultread-onlycurrentLine Trscv Network Tx Timing Fault :This OID indicates a Tx Timing Fault is detected on the Line Trscv Network interface <Help> Alarm indicating a Tx Timing Fa…
1.3.6.1.4.1.20044.54.2.1.3.49.13Scalarrm10010mpAlmNetTxReferenceClockFaultread-onlycurrentLine Trscv Network Tx Ref Clock Fault :This OID indicates a Tx Reference Clock Fault is detected on the Line Trscv Network interface <Help> Alarm indicating a …
1.3.6.1.4.1.20044.54.2.1.3.49.14Scalarrm10010mpAlmNetTxCmuLockFaultread-onlycurrentLine Trscv Network Tx CMU Lock Fault :This OID indicates a Tx Clock Multiplier Unit Lock Fault is detected on the Line Trscv Network interface <Help> Alarm ind…
1.3.6.1.4.1.20044.54.2.1.3.49.15Scalarrm10010mpAlmNetTxOutOfAlignmentread-onlycurrentLine Trscv Network Tx Out Of Alignment :This OID indicates a Tx Out of Alignment is detected on the Line Trscv Network interface <Help> Alarm indicating a Tx O…
1.3.6.1.4.1.20044.54.2.1.3.49.16Scalarrm10010mpAlmNetTxLossOfAlignmentread-onlycurrentLine Trscv Network Tx Loss Of Alignment :This OID indicates a Tx Loss of Alignment is detected on the Line Trscv Network interface <Help> Alarm indicating a Tx…
1.3.6.1.4.1.20044.54.2.1.3.50Noderm10010mpAlmmsaNetworkRxAlignment
1.3.6.1.4.1.20044.54.2.1.3.50.12Scalarrm10010mpAlmNetRxTimingFaultread-onlycurrentLine Trscv Network Rx Timing Fault :This OID indicates a Rx Timing Fault is detected on the Line Trscv Network interface <Help> Alarm indicating a Rx Timing Fa…
1.3.6.1.4.1.20044.54.2.1.3.50.13Scalarrm10010mpAlmNetRxOutOfAlignmentread-onlycurrentLine Trscv Network Rx Out Of Alignment :This OID indicates a Rx Out of Alignment is detected on the Line Trscv Network interface <Help> Alarm indicating a Rx O…
1.3.6.1.4.1.20044.54.2.1.3.50.14Scalarrm10010mpAlmNetRxLossOfAlignmentread-onlycurrentLine Trscv Network Rx Loss Of Alignment :This OID indicates a Rx Loss of Alignment is detected on the Line Trscv Network interface <Help> Alarm indicating a Rx…
1.3.6.1.4.1.20044.54.2.1.3.50.15Scalarrm10010mpAlmNetRxModemLockFaultread-onlycurrentLine Trscv Network Rx Modem Lock Fault :This OID indicates a Rx Modem Lock Fault is detected on the Line Trscv Network interface <Help> Alarm indicating a Rx M…
1.3.6.1.4.1.20044.54.2.1.3.50.16Scalarrm10010mpAlmNetRxModemSyncDetectFaultread-onlycurrentLine Trscv Network Rx Modem Sync Detect Fault :This OID indicates a Rx Modem Synchronisation Detection Fault is detected on the Line Trscv Network interface <H…
1.3.6.1.4.1.20044.54.2.1.3.51Noderm10010mpAlmmsaNetworkHostNetworkAlarmSummary
1.3.6.1.4.1.20044.54.2.1.3.51.11Scalarrm10010mpAlmNetworkTxAlignmentread-onlycurrentLine Trscv Network Tx Alignment :This OID indicates a Tx Alignment Fault is detected on the Line Trscv Network interface <Help> Synthesis Alarm indicating a Tx…
1.3.6.1.4.1.20044.54.2.1.3.51.12Scalarrm10010mpAlmNetworkRxAlignmentread-onlycurrentLine Trscv Network Rx Alignment :This OID indicates a Rx Alignment Fault is detected on the Line Trscv Network interface <Help> Synthesis Alarm indicating a Rx…
1.3.6.1.4.1.20044.54.2.1.3.51.13Scalarrm10010mpAlmNetworkRxOtnread-onlycurrentLine Trscv Network Rx OTN :This OID indicates a Rx OTN Fault is detected on the Line Trscv Network interface <Help> Synthesis Alarm indicating a Rx OTN Fault i…
1.3.6.1.4.1.20044.54.2.1.3.51.14Scalarrm10010mpAlmHostRxAlignmentread-onlycurrentLine Trscv Host Rx Alignment :This OID indicates a Rx Alignment Fault is detected on the Line Trscv Host interface <Help> Synthesis Alarm indicating a Rx Align…
1.3.6.1.4.1.20044.54.2.1.3.51.15Scalarrm10010mpAlmHostTxAlignmentread-onlycurrentLine Trscv Host Tx Alignment :This OID indicates a Tx Alignment Fault is detected on the Line Trscv Host interface <Help> Synthesis Alarm indicating a Tx Align…
1.3.6.1.4.1.20044.54.2.1.3.51.16Scalarrm10010mpAlmHostTxOtnStatusread-onlycurrentLine Trscv Host Tx OTN :This OID indicates a Tx OTN Fault is detected on the Line Trscv Host interface <Help> Synthesis Alarm indicating a Tx OTN Fault is dete…
1.3.6.1.4.1.20044.54.2.1.3.52Noderm10010mpAlmmsaHostTxAlignment
1.3.6.1.4.1.20044.54.2.1.3.52.13Scalarrm10010mpAlmHostTxDeskewLockFaultread-onlycurrentLine Trscv Host Tx Deskew Lock Fault :This OID indicates a Tx Deskew Lock Fault is detected on the Line Trscv Host interface <Help> Alarm indicating a Tx Deske…
1.3.6.1.4.1.20044.54.2.1.3.52.14Scalarrm10010mpAlmHostTxOutOfAlignmentread-onlycurrentLine Trscv Host Tx Out Of Alignment :This OID indicates a Tx Out of Alignment is detected on the Line Trscv Host interface <Help> Alarm indicating a Tx Out of …
1.3.6.1.4.1.20044.54.2.1.3.52.15Scalarrm10010mpAlmHostTxLossOfAlignmentread-onlycurrentLine Trscv Host Tx Loss Of Alignment :This OID indicates a Tx Loss of Alignment is detected on the Line Trscv Host interface <Help> Alarm indicating a Tx Loss …
1.3.6.1.4.1.20044.54.2.1.3.52.16Scalarrm10010mpAlmHostTxCdrLockFaultread-onlycurrentLine Trscv Host Tx CDR Lock Fault :This OID indicates a Tx Clock Data Recovery Lock Fault is detected on the Line Trscv Host interface <Help> Alarm indicating …
1.3.6.1.4.1.20044.54.2.1.3.53Noderm10010mpAlmmsaHostRxAlignment
1.3.6.1.4.1.20044.54.2.1.3.53.14Scalarrm10010mpAlmHostRxCmuLockFaultread-onlycurrentLine Trscv Host Rx CMU Lock Fault :This OID indicates a Rx Clock Multiplier Unit Lock Fault is detected on the Line Trscv Host interface <Help> Alarm indicatin…
1.3.6.1.4.1.20044.54.2.1.3.53.15Scalarrm10010mpAlmHostRxOutOfAlignmentread-onlycurrentLine Trscv Host Rx Out Of Alignment :This OID indicates a Rx Out of Alignment is detected on the Line Trscv Host interface <Help> Alarm indicating a Rx Out of …
1.3.6.1.4.1.20044.54.2.1.3.53.16Scalarrm10010mpAlmHostRxLossOfAlignmentread-onlycurrentLine Trscv Host Rx Loss Of Alignment :This OID indicates a Rx Loss of Alignment is detected on the Line Trscv Host interface <Help> Alarm indicating a Rx Loss …
1.3.6.1.4.1.20044.54.2.2Noderm10010mpAlmClient
1.3.6.1.4.1.20044.54.2.2.1Noderm10010mpAlmClientNurg
1.3.6.1.4.1.20044.54.2.2.1.56Tablerm10010mpAlmclientNetworkLaneAlarmWarningTablenot-accessiblecurrentList of rm10010mpAlmclientNetworkLaneAlarmWarning Article
1.3.6.1.4.1.20044.54.2.2.1.56.1Rowrm10010mpAlmclientNetworkLaneAlarmWarningEntrynot-accessiblecurrentRow definition for the rm10010mpAlmclientNetworkLaneAlarmWarning table
1.3.6.1.4.1.20044.54.2.2.1.56.1.1Columnrm10010mpAlmclientNetworkLaneAlarmWarningIndexread-onlycurrentIndex definition for the rm10010mpAlmclientNetworkLaneAlarmWarning table
1.3.6.1.4.1.20044.54.2.2.1.56.1.2Columnrm10010mpAlmClientRxPowerLowAlarmPortnread-onlycurrentClient Trscv Rx Power Low Alarm :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indic…
1.3.6.1.4.1.20044.54.2.2.1.56.1.3Columnrm10010mpAlmClientRxPowerLowWarningPortnread-onlycurrentClient Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning i…
1.3.6.1.4.1.20044.54.2.2.1.56.1.4Columnrm10010mpAlmClientRxPowerHighWarningPortnread-onlycurrentClient Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning…
1.3.6.1.4.1.20044.54.2.2.1.56.1.5Columnrm10010mpAlmClientRxPowerHighAlarmPortnread-onlycurrentClient Trscv Rx Power High Alarm :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm ind…
1.3.6.1.4.1.20044.54.2.2.1.56.1.6Columnrm10010mpAlmLaserTempLowAlarmPortnread-onlycurrentClient Trscv Laser Temp Low Alarm :This OID indicates that the Trscv Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help> Ala…
1.3.6.1.4.1.20044.54.2.2.1.56.1.7Columnrm10010mpAlmClientLaserTempLowWarningPortnread-onlycurrentClient Trscv Laser Temp Low Warning :This OID indicates that the Trscv Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help> W…
1.3.6.1.4.1.20044.54.2.2.1.56.1.8Columnrm10010mpAlmClientLaserTempHighWarningPortnread-onlycurrentClient Trscv Laser Temp High Warning :This OID indicates that the Trscv Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Help>…
1.3.6.1.4.1.20044.54.2.2.1.56.1.9Columnrm10010mpAlmClientLaserTempHighAlarmPortnread-onlycurrentClient Trscv Laser Temp High Alarm :This OID indicates that the Trscv Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Help> A…
1.3.6.1.4.1.20044.54.2.2.1.56.1.10Columnrm10010mpAlmClientTxPowerLowAlarmPortnread-onlycurrentClient Trscv Tx Power Low Alarm :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indi…
1.3.6.1.4.1.20044.54.2.2.1.56.1.11Columnrm10010mpAlmClientTxPowerLowWarningPortnread-onlycurrentClient Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.54.2.2.1.56.1.12Columnrm10010mpAlmClientTxPowerHighWarningPortnread-onlycurrentClient Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.54.2.2.1.56.1.13Columnrm10010mpAlmClientTxPowerHighAlarmPortnread-onlycurrentClient Trscv Tx Power High Alarm :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm in…
1.3.6.1.4.1.20044.54.2.2.1.56.1.14Columnrm10010mpAlmClientBiasLowAlarmPortnread-onlycurrentClient Trscv Bias Low Alarm :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in…
1.3.6.1.4.1.20044.54.2.2.1.56.1.15Columnrm10010mpAlmClientBiasLowWarningPortnread-onlycurrentClient Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.54.2.2.1.56.1.16Columnrm10010mpAlmClientBiasHighWarningPortnread-onlycurrentClient Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warn…
1.3.6.1.4.1.20044.54.2.2.1.56.1.17Columnrm10010mpAlmClientBiasHighAlarmPortnread-onlycurrentClient Trscv Bias High Alarm :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.54.2.2.1.232Tablerm10010mpAlmclientSfpWarnDdmTablenot-accessiblecurrentList of rm10010mpAlmclientSfpWarnDdm Article
1.3.6.1.4.1.20044.54.2.2.1.232.1Rowrm10010mpAlmclientSfpWarnDdmEntrynot-accessiblecurrentRow definition for the rm10010mpAlmclientSfpWarnDdm table
1.3.6.1.4.1.20044.54.2.2.1.232.1.1Columnrm10010mpAlmclientSfpWarnDdmIndexread-onlycurrentIndex definition for the rm10010mpAlmclientSfpWarnDdm table
1.3.6.1.4.1.20044.54.2.2.1.232.1.2Columnrm10010mpAlmTxPwLowWngPortnread-onlycurrentClient Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.54.2.2.1.232.1.3Columnrm10010mpAlmTxPwrHighWngPortnread-onlycurrentClient Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.54.2.2.1.232.1.4Columnrm10010mpAlmTxBiasLowWngPortnread-onlycurrentClient Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warnin…
1.3.6.1.4.1.20044.54.2.2.1.232.1.5Columnrm10010mpAlmTxBiasHighWngPortnread-onlycurrentClient Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warn…
1.3.6.1.4.1.20044.54.2.2.1.232.1.6Columnrm10010mpAlmVccLowWngPortnread-onlycurrentClient Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Warn…
1.3.6.1.4.1.20044.54.2.2.1.232.1.7Columnrm10010mpAlmVccHighWngPortnread-onlycurrentClient Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Wa…
1.3.6.1.4.1.20044.54.2.2.1.232.1.8Columnrm10010mpAlmTempLowWngPortnread-onlycurrentClient Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indic…
1.3.6.1.4.1.20044.54.2.2.1.232.1.9Columnrm10010mpAlmTempHighWngPortnread-onlycurrentClient Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning ind…
1.3.6.1.4.1.20044.54.2.2.1.232.1.16Columnrm10010mpAlmRxPwrLowWngPortnread-onlycurrentClient Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning i…
1.3.6.1.4.1.20044.54.2.2.1.232.1.17Columnrm10010mpAlmRxPwrHighWngPortnread-onlycurrentClient Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning…
1.3.6.1.4.1.20044.54.2.2.2Noderm10010mpAlmClientUrg
1.3.6.1.4.1.20044.54.2.2.2.72Tablerm10010mpAlmclientNetworkLaneFaultTablenot-accessiblecurrentList of rm10010mpAlmclientNetworkLaneFault Article
1.3.6.1.4.1.20044.54.2.2.2.72.1Rowrm10010mpAlmclientNetworkLaneFaultEntrynot-accessiblecurrentRow definition for the rm10010mpAlmclientNetworkLaneFault table
1.3.6.1.4.1.20044.54.2.2.2.72.1.1Columnrm10010mpAlmclientNetworkLaneFaultIndexread-onlycurrentIndex definition for the rm10010mpAlmclientNetworkLaneFault table
1.3.6.1.4.1.20044.54.2.2.2.72.1.4Columnrm10010mpAlmClientLaneRxFifoErrorPortnread-onlycurrentClient Network Lane Rx FIFO Error :This OID indicates a Rx FIFO Error on the Client Trscv Network Lane <Help> Alarm indicating a Rx FIFO Error on the Client Tr…
1.3.6.1.4.1.20044.54.2.2.2.72.1.5Columnrm10010mpAlmClientLaneRxLolPortnread-onlycurrentClient Network Lane Rx Loss Of Lock :This OID indicates a Rx Loss of Lock on the Client Trscv Network Lane <Help> Alarm indicating a Rx Loss of Lock on the Cli…
1.3.6.1.4.1.20044.54.2.2.2.72.1.6Columnrm10010mpAlmClientLaneRxLosPortnread-onlycurrentClient Network Lane Rx Loss Of Signal :This OID indicates a Rx Loss of Signal on the Client Trscv Network Lane <Help> Alarm indicating a Rx Loss of Signal on t…
1.3.6.1.4.1.20044.54.2.2.2.72.1.8Columnrm10010mpAlmClientLaneTxLolPortnread-onlycurrentClient Network Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Client Trscv Network Lane <Help> Alarm indicating a Tx Loss of Lock on the Cli…
1.3.6.1.4.1.20044.54.2.2.2.72.1.9Columnrm10010mpAlmClientLaneTxLosfPortnread-onlycurrentClient Network Lane Tx Loss Of Signal Functionality :This OID indicates a Tx Loss of Signal Functionality on the Client Trscv Network Lane <Help> Alarm indicat…
1.3.6.1.4.1.20044.54.2.2.2.72.1.15Columnrm10010mpAlmClientLaneApdPowerSupplyPortnread-onlycurrentClient Network Lane APD Power Supply :This OID indicates an APD Power supply failure on the Client Trscv Network Lane <Help> Alarm indicating an APD Power supp…
1.3.6.1.4.1.20044.54.2.2.2.72.1.16Columnrm10010mpAlmClientLaneWavelengthUnlockedPortnread-onlycurrentClient Network Lane Wavelength Unlock :This OID indicates a Wavelength unlock on the Client Trscv Network Lane <Help> Alarm indicating a Wavelength unlock on t…
1.3.6.1.4.1.20044.54.2.2.2.72.1.17Columnrm10010mpAlmClientLaneTecFaultPortnread-onlycurrentClient Network Lane TEC Fault :This OID indicates a TEC Fault on the Client Trscv Network Lane <Help> Alarm indicating a TEC Fault on the Client Trscv Network …
1.3.6.1.4.1.20044.54.2.2.2.88Tablerm10010mpAlmclientHostLaneFaultTablenot-accessiblecurrentList of rm10010mpAlmclientHostLaneFault Article
1.3.6.1.4.1.20044.54.2.2.2.88.1Rowrm10010mpAlmclientHostLaneFaultEntrynot-accessiblecurrentRow definition for the rm10010mpAlmclientHostLaneFault table
1.3.6.1.4.1.20044.54.2.2.2.88.1.1Columnrm10010mpAlmclientHostLaneFaultIndexread-onlycurrentIndex definition for the rm10010mpAlmclientHostLaneFault table
1.3.6.1.4.1.20044.54.2.2.2.88.1.2Columnrm10010mpAlmClientLossOfSyncPortnread-onlycurrentClient Frame Alignment Loss :This OID indicates the module is not aligned with the incoming Client signal <Help> Alarm indicating the module is not aligned wit…
1.3.6.1.4.1.20044.54.2.2.2.88.1.3Columnrm10010mpAlmClientInputLossOfSigPortnread-onlycurrentClient Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Client Trscv <Help> Alarm indicating a Loss of Signal is detected on the Cl…
1.3.6.1.4.1.20044.54.2.2.2.88.1.4Columnrm10010mpAlmClientLanesMarkerUnlockPortnread-onlycurrentClient Lanes Marker Unlock :This OID indicates the Client lanes marker alignment is not lock <Help> Alarm indicating the Client lanes marker alignment is not l…
1.3.6.1.4.1.20044.54.2.2.2.88.1.5Columnrm10010mpAlmClientLanes6466UnlockPortnread-onlycurrentClient Lanes 64/66b Unlock :This OID indicates the Client 64/66b decoder is not lock <Help> Alarm indicating the Client 64/66b decoder is not lock <Condtype> C…
1.3.6.1.4.1.20044.54.2.2.2.88.1.6Columnrm10010mpAlmClientLanesNotAlignedPortnread-onlycurrentClient Lanes Not Aligned :This OID indicates the Client lanes are not aligned <Help> Alarm indicating the Client lanes are not aligned <Condtype> CLIENT_LANES_…
1.3.6.1.4.1.20044.54.2.2.2.88.1.7Columnrm10010mpAlmClientCsfDetectedPortnread-onlycurrentClient Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client…
1.3.6.1.4.1.20044.54.2.2.2.88.1.10Columnrm10010mpAlmClientTxHostLolPortnread-onlycurrentClient Host Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Client Trscv Host Lane <Help> Alarm indicating a Tx Loss of Lock on the Client Tr…
1.3.6.1.4.1.20044.54.2.2.2.88.1.11Columnrm10010mpAlmClientLaneTxFifoErrorPortnread-onlycurrentClient Host Lane Tx FIFO Error :This OID indicates a Tx FIFO Error on the Client Trscv Host Lane <Help> Alarm indicating a Tx FIFO Error on the Client Trscv Ho…
1.3.6.1.4.1.20044.54.2.2.2.216Tablerm10010mpAlmclientSfpAlmDdmTablenot-accessiblecurrentList of rm10010mpAlmclientSfpAlmDdm Article
1.3.6.1.4.1.20044.54.2.2.2.216.1Rowrm10010mpAlmclientSfpAlmDdmEntrynot-accessiblecurrentRow definition for the rm10010mpAlmclientSfpAlmDdm table
1.3.6.1.4.1.20044.54.2.2.2.216.1.1Columnrm10010mpAlmclientSfpAlmDdmIndexread-onlycurrentIndex definition for the rm10010mpAlmclientSfpAlmDdm table
1.3.6.1.4.1.20044.54.2.2.2.216.1.2Columnrm10010mpAlmTxPwrLowAlaPortnread-onlycurrentClient Trscv Tx Power Low :This OID indicates that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm in…
1.3.6.1.4.1.20044.54.2.2.2.216.1.3Columnrm10010mpAlmTxPwrHighAlaPortnread-onlycurrentClient Trscv Tx Power High :This OID indicates that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.54.2.2.2.216.1.4Columnrm10010mpAlmTxBiasLowAlaPortnread-onlycurrentClient Trscv Bias Low :This OID indicates that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm …
1.3.6.1.4.1.20044.54.2.2.2.216.1.5Columnrm10010mpAlmTxBiasHighAlaPortnread-onlycurrentClient Trscv Bias High :This OID indicates that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM <Help> Alar…
1.3.6.1.4.1.20044.54.2.2.2.216.1.6Columnrm10010mpAlmVccLowAlaPortnread-onlycurrentClient Trscv Power Supply Low :This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM <Help> Alar…
1.3.6.1.4.1.20044.54.2.2.2.216.1.7Columnrm10010mpAlmVccHighAlaPortnread-onlycurrentClient Trscv Power Supply High :This OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM <Help> Al…
1.3.6.1.4.1.20044.54.2.2.2.216.1.8Columnrm10010mpAlmTempLowAlaPortnread-onlycurrentClient Trscv Temp Low :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicat…
1.3.6.1.4.1.20044.54.2.2.2.216.1.9Columnrm10010mpAlmTempHighAlaPortnread-onlycurrentClient Trscv Temp High :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indic…
1.3.6.1.4.1.20044.54.2.2.2.216.1.16Columnrm10010mpAlmRxPwrLowAlaPortnread-onlycurrentClient Trscv Rx Power Low :This OID indicates that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm ind…
1.3.6.1.4.1.20044.54.2.2.2.216.1.17Columnrm10010mpAlmRxPwrHighAlaPortnread-onlycurrentClient Trscv Rx Power High :This OID indicates that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm i…
1.3.6.1.4.1.20044.54.2.2.3Noderm10010mpAlmClientCrit
1.3.6.1.4.1.20044.54.2.2.3.8Tablerm10010mpAlmsynthAlmPortTablenot-accessiblecurrentList of rm10010mpAlmsynthAlmPort Article
1.3.6.1.4.1.20044.54.2.2.3.8.1Rowrm10010mpAlmsynthAlmPortEntrynot-accessiblecurrentRow definition for the rm10010mpAlmsynthAlmPort table
1.3.6.1.4.1.20044.54.2.2.3.8.1.1Columnrm10010mpAlmsynthAlmPortIndexread-onlycurrentIndex definition for the rm10010mpAlmsynthAlmPort table
1.3.6.1.4.1.20044.54.2.2.3.8.1.2Columnrm10010mpAlmSfpAbsentPortnread-onlycurrentClient Optical Module Absent :This OID indicates that the Transceiver is not present in the client port. <Help> This alarm indicates if the client transceiver …
1.3.6.1.4.1.20044.54.2.2.3.8.1.3Columnrm10010mpAlmDdmAbsentPortnread-onlycurrentDDM Supported On Client Trscv :This OID indicates that the Client transceiver supports the Digital Diagnostic Monitoring function <Help> This status indicates …
1.3.6.1.4.1.20044.54.2.2.3.8.1.5Columnrm10010mpAlmHwFailAccPortnread-onlycurrentClient HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Help> This alarm indicates a failure on client port, most pro…
1.3.6.1.4.1.20044.54.2.2.3.8.1.6Columnrm10010mpAlmDwLsdPortnread-onlycurrentClient Trscv Laser Shutdown :This OID indicates the Client transceiver laser is shutdown <Help> This status indicates if the client transceiver laser is shutdo…
1.3.6.1.4.1.20044.54.2.2.3.8.1.7Columnrm10010mpAlmClientLocalOosPortnread-onlycurrentLocal Client Port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local c…
1.3.6.1.4.1.20044.54.2.2.3.8.1.8Columnrm10010mpAlmClientRemoteOosPortnread-onlycurrentRemote Client Port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the remot…
1.3.6.1.4.1.20044.54.2.2.3.8.1.9Columnrm10010mpAlmDwCaisPortnread-onlycurrentClient AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indicates if a Client Alarm Indication Signal is…
1.3.6.1.4.1.20044.54.2.2.3.8.1.10Columnrm10010mpAlmSfpDdmWarningPortnread-onlycurrentWarning On Client Trscv DDM :This OID indicates a warning is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Warning has be…
1.3.6.1.4.1.20044.54.2.2.3.8.1.11Columnrm10010mpAlmSfpDdmAlmPortnread-onlycurrentAlarm On Client Trscv DDM :This OID indicates an alarm is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Alarm has been de…
1.3.6.1.4.1.20044.54.2.2.3.8.1.13Columnrm10010mpAlmFailAccPortnread-onlycurrentClient Access Fail :This OID indicates a failure on the Client port <Help> This alarm indicates a failure on the Client port <Condtype> FAIL_ACC_1 <Probcause> …
1.3.6.1.4.1.20044.54.2.2.3.8.1.17Columnrm10010mpAlmUpCsfPortnread-onlycurrentClient Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu…
1.3.6.1.4.1.20044.54.2.3Noderm10010mpAlmLine
1.3.6.1.4.1.20044.54.2.3.1Noderm10010mpAlmLineNurg
1.3.6.1.4.1.20044.54.2.3.1.104Tablerm10010mpAlmlineNetworkLaneAlarmWarning1Tablenot-accessiblecurrentList of rm10010mpAlmlineNetworkLaneAlarmWarning1 Article
1.3.6.1.4.1.20044.54.2.3.1.104.1Rowrm10010mpAlmlineNetworkLaneAlarmWarning1Entrynot-accessiblecurrentRow definition for the rm10010mpAlmlineNetworkLaneAlarmWarning1 table
1.3.6.1.4.1.20044.54.2.3.1.104.1.1Columnrm10010mpAlmlineNetworkLaneAlarmWarning1Indexread-onlycurrentIndex definition for the rm10010mpAlmlineNetworkLaneAlarmWarning1 table
1.3.6.1.4.1.20044.54.2.3.1.104.1.2Columnrm10010mpAlmLineRxPowerLowAlarmPortnread-onlycurrentLine Trscv Rx Power Low Alarm :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicat…
1.3.6.1.4.1.20044.54.2.3.1.104.1.3Columnrm10010mpAlmLineRxPowerLowWarningPortnread-onlycurrentLine Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning ind…
1.3.6.1.4.1.20044.54.2.3.1.104.1.4Columnrm10010mpAlmLineRxPowerHighWarningPortnread-onlycurrentLine Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning i…
1.3.6.1.4.1.20044.54.2.3.1.104.1.5Columnrm10010mpAlmLineRxPowerHighAlarmPortnread-onlycurrentLine Trscv Rx Power High Alarm :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indic…
1.3.6.1.4.1.20044.54.2.3.1.104.1.6Columnrm10010mpAlmLineLaserTempLowAlarmPortnread-onlycurrentLine Trscv Tx Laser Temp Low Alarm :This OID indicates that the Trscv Tx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help>…
1.3.6.1.4.1.20044.54.2.3.1.104.1.7Columnrm10010mpAlmLineLaserTempLowWarningPortnread-onlycurrentLine Trscv Tx Laser Temp Low Warning :This OID indicates that the Trscv Tx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Hel…
1.3.6.1.4.1.20044.54.2.3.1.104.1.8Columnrm10010mpAlmLineLaserTempHighWarningPortnread-onlycurrentLine Trscv Tx Laser Temp High Warning :This OID indicates that the Trscv Tx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <H…
1.3.6.1.4.1.20044.54.2.3.1.104.1.9Columnrm10010mpAlmLineLaserTempHighAlarmPortnread-onlycurrentLine Trscv Tx Laser Temp High Alarm :This OID indicates that the Trscv Tx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Hel…
1.3.6.1.4.1.20044.54.2.3.1.104.1.10Columnrm10010mpAlmLineTxPowerLowAlarmPortnread-onlycurrentLine Trscv Tx Power Low Alarm :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indica…
1.3.6.1.4.1.20044.54.2.3.1.104.1.11Columnrm10010mpAlmLineTxPowerLowWarningPortnread-onlycurrentLine Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning in…
1.3.6.1.4.1.20044.54.2.3.1.104.1.12Columnrm10010mpAlmLineTxPowerHighWarningPortnread-onlycurrentLine Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warning …
1.3.6.1.4.1.20044.54.2.3.1.104.1.13Columnrm10010mpAlmLineTxPowerHighAlarmPortnread-onlycurrentLine Trscv Tx Power High Alarm :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indi…
1.3.6.1.4.1.20044.54.2.3.1.104.1.14Columnrm10010mpAlmLineBiasLowAlarmPortnread-onlycurrentLine Trscv Tx Bias Low Alarm :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alarm i…
1.3.6.1.4.1.20044.54.2.3.1.104.1.15Columnrm10010mpAlmLineBiasLowWarningPortnread-onlycurrentLine Trscv Tx Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warni…
1.3.6.1.4.1.20044.54.2.3.1.104.1.16Columnrm10010mpAlmLineBiasHighWarningPortnread-onlycurrentLine Trscv Tx Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> War…
1.3.6.1.4.1.20044.54.2.3.1.104.1.17Columnrm10010mpAlmLineBiasHighAlarmPortnread-onlycurrentLine Trscv Tx Bias High Alarm :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Alarm…
1.3.6.1.4.1.20044.54.2.3.1.120Tablerm10010mpAlmlineNetworkLaneAlarmWarning2Tablenot-accessiblecurrentList of rm10010mpAlmlineNetworkLaneAlarmWarning2 Article
1.3.6.1.4.1.20044.54.2.3.1.120.1Rowrm10010mpAlmlineNetworkLaneAlarmWarning2Entrynot-accessiblecurrentRow definition for the rm10010mpAlmlineNetworkLaneAlarmWarning2 table
1.3.6.1.4.1.20044.54.2.3.1.120.1.1Columnrm10010mpAlmlineNetworkLaneAlarmWarning2Indexread-onlycurrentIndex definition for the rm10010mpAlmlineNetworkLaneAlarmWarning2 table
1.3.6.1.4.1.20044.54.2.3.1.120.1.2Columnrm10010mpAlmTxModulatorBiasLowAlarmPortnread-onlycurrentLine Trscv Tx Modulator Bias Low Alarm :This OID indicates that the Trscv Tx modulator bias current is lower than the threshold value written in the Trscv EEPR…
1.3.6.1.4.1.20044.54.2.3.1.120.1.3Columnrm10010mpAlmTxModulatorBiasLowWarningPortnread-onlycurrentLine Trscv Tx Modulator Bias Low Warning :This OID indicates that the Trscv Tx modulator bias current is lower than the threshold value written in the Trscv EE…
1.3.6.1.4.1.20044.54.2.3.1.120.1.4Columnrm10010mpAlmTxModulatorBiasHighWarningPortnread-onlycurrentLine Trscv Tx Modulator Bias High Warning :This OID indicates that the Trscv Tx modulator bias current is higher than the threshold value written in the Trscv …
1.3.6.1.4.1.20044.54.2.3.1.120.1.5Columnrm10010mpAlmTxModulatorBiasHighAlarmPortnread-onlycurrentLine Trscv Tx Modulator Bias High Alarm :This OID indicates that the Trscv Tx modulator bias current is higher than the threshold value written in the Trscv EE…
1.3.6.1.4.1.20044.54.2.3.1.120.1.6Columnrm10010mpAlmRxLaserTempLowAlarmPortnread-onlycurrentLine Trscv Rx Laser Temp Low Alarm :This OID indicates that the Trscv Rx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Help>…
1.3.6.1.4.1.20044.54.2.3.1.120.1.7Columnrm10010mpAlmRxLaserTempLowWarningPortnread-onlycurrentLine Trscv Rx Laser Temp Low Warning :This OID indicates that the Trscv Rx Laser Temperature is lower than the threshold value written in the Trscv EEPROM <Hel…
1.3.6.1.4.1.20044.54.2.3.1.120.1.8Columnrm10010mpAlmRxLaserTempHighWarningPortnread-onlycurrentLine Trscv Rx Laser Temp High Warning :This OID indicates that the Trscv Rx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <H…
1.3.6.1.4.1.20044.54.2.3.1.120.1.9Columnrm10010mpAlmRxLaserTempHighAlarmPortnread-onlycurrentLine Trscv Rx Laser Temp High Alarm :This OID indicates that the Trscv Rx Laser Temperature is higher than the threshold value written in the Trscv EEPROM <Hel…
1.3.6.1.4.1.20044.54.2.3.1.120.1.10Columnrm10010mpAlmRxLaserOutputLowAlarmPortnread-onlycurrentLine Trscv Rx Output Power Low Alarm :This OID indicates that the Trscv Rx output power is lower than the threshold value written in the Trscv EEPROM <Help> Al…
1.3.6.1.4.1.20044.54.2.3.1.120.1.11Columnrm10010mpAlmRxLaserOutputLowWarningPortnread-onlycurrentLine Trscv Rx Output Power Low Warning :This OID indicates that the Trscv Rx output power is lower than the threshold value written in the Trscv EEPROM <Help> …
1.3.6.1.4.1.20044.54.2.3.1.120.1.12Columnrm10010mpAlmRxLaserOutputHighWarningPortnread-onlycurrentLine Trscv Rx Output Power High Warning :This OID indicates that the Trscv Rx output power is higher than the threshold value written in the Trscv EEPROM <Help…
1.3.6.1.4.1.20044.54.2.3.1.120.1.13Columnrm10010mpAlmRxLaserOutputHighAlarmPortnread-onlycurrentLine Trscv Rx Output Power High Alarm :This OID indicates that the Trscv Rx output power is higher than the threshold value written in the Trscv EEPROM <Help> …
1.3.6.1.4.1.20044.54.2.3.1.120.1.14Columnrm10010mpAlmRxLaserBiasLowAlarmPortnread-onlycurrentLine Trscv Rx Bias Low Alarm :This OID indicates that the Trscv Rx laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Alar…
1.3.6.1.4.1.20044.54.2.3.1.120.1.15Columnrm10010mpAlmRxLaserBiasLowWarningPortnread-onlycurrentLine Trscv Rx Bias Low Warning :This OID indicates that the Trscv Rx laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Wa…
1.3.6.1.4.1.20044.54.2.3.1.120.1.16Columnrm10010mpAlmRxLaserBiasHighWarningPortnread-onlycurrentLine Trscv Rx Bias High Warning :This OID indicates that the Trscv Rx laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> …
1.3.6.1.4.1.20044.54.2.3.1.120.1.17Columnrm10010mpAlmRxLaserBiasHighAlarmPortnread-onlycurrentLine Trscv Rx Bias High Alarm :This OID indicates that the Trscv Rx laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Al…
1.3.6.1.4.1.20044.54.2.3.2Noderm10010mpAlmLineUrg
1.3.6.1.4.1.20044.54.2.3.2.136Tablerm10010mpAlmlineNetworkLaneFaultTablenot-accessiblecurrentList of rm10010mpAlmlineNetworkLaneFault Article
1.3.6.1.4.1.20044.54.2.3.2.136.1Rowrm10010mpAlmlineNetworkLaneFaultEntrynot-accessiblecurrentRow definition for the rm10010mpAlmlineNetworkLaneFault table
1.3.6.1.4.1.20044.54.2.3.2.136.1.1Columnrm10010mpAlmlineNetworkLaneFaultIndexread-onlycurrentIndex definition for the rm10010mpAlmlineNetworkLaneFault table
1.3.6.1.4.1.20044.54.2.3.2.136.1.3Columnrm10010mpAlmLineLaneRxTecFaultPortnread-onlycurrentLine Network Lane Rx TEC Fault :This OID indicates a Rx TEC Fault on the Line Trscv Network Lane <Help> Alarm indicating a Rx TEC Fault on the Line Trscv Netwo…
1.3.6.1.4.1.20044.54.2.3.2.136.1.4Columnrm10010mpAlmLineLaneRxFifoErrorPortnread-onlycurrentLine Network Lane Rx FIFO Error :This OID indicates a Rx FIFO Error on the Line Trscv Network Lane <Help> Alarm indicating a Rx FIFO Error on the Line Trscv Ne…
1.3.6.1.4.1.20044.54.2.3.2.136.1.5Columnrm10010mpAlmLineLaneRxLolPortnread-onlycurrentLine Network Lane Rx Loss Of Lock :This OID indicates a Rx Loss of Lock on the Line Trscv Network Lane <Help> Alarm indicating a Rx Loss of Lock on the Line Tr…
1.3.6.1.4.1.20044.54.2.3.2.136.1.6Columnrm10010mpAlmLineLaneRxLosPortnread-onlycurrentLine Network Lane Rx Loss Of Signal :This OID indicates a Rx Loss of Signal on the Line Trscv Network Lane <Help> Alarm indicating a Rx Loss of Signal on the L…
1.3.6.1.4.1.20044.54.2.3.2.136.1.8Columnrm10010mpAlmLineLaneTxLolPortnread-onlycurrentLine Network Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Line Trscv Network Lane <Help> Alarm indicating a Tx Loss of Lock on the Line Tr…
1.3.6.1.4.1.20044.54.2.3.2.136.1.9Columnrm10010mpAlmLineLaneTxLosfPortnread-onlycurrentLine Network Lane Tx Loss Of Signal Functionality :This OID indicates a Tx Loss of Signal Functionality on the Line Trscv Network Lane <Help> Alarm indicating …
1.3.6.1.4.1.20044.54.2.3.2.136.1.15Columnrm10010mpAlmLineLaneApdPowerSupplyPortnread-onlycurrentLine Network Lane APD Power Supply :This OID indicates an APD Power supply failure on the Line Trscv Network Lane <Help> Alarm indicating an APD Power supply f…
1.3.6.1.4.1.20044.54.2.3.2.136.1.16Columnrm10010mpAlmLineLaneWavelengthUnlockedPortnread-onlycurrentLine Network Lane Wavelength Unlock :This OID indicates a Wavelength unlock on the Line Trscv Network Lane <Help> Alarm indicating a Wavelength unlock on the L…
1.3.6.1.4.1.20044.54.2.3.2.136.1.17Columnrm10010mpAlmLineLaneTecFaultPortnread-onlycurrentLine Network Lane TEC Fault :This OID indicates a Tx TEC Fault on the Line Trscv Network Lane <Help> Alarm indicating a Tx TEC Fault on the Line Trscv Network …
1.3.6.1.4.1.20044.54.2.3.2.152Tablerm10010mpAlmlineHostLaneFaultTablenot-accessiblecurrentList of rm10010mpAlmlineHostLaneFault Article
1.3.6.1.4.1.20044.54.2.3.2.152.1Rowrm10010mpAlmlineHostLaneFaultEntrynot-accessiblecurrentRow definition for the rm10010mpAlmlineHostLaneFault table
1.3.6.1.4.1.20044.54.2.3.2.152.1.1Columnrm10010mpAlmlineHostLaneFaultIndexread-onlycurrentIndex definition for the rm10010mpAlmlineHostLaneFault table
1.3.6.1.4.1.20044.54.2.3.2.152.1.2Columnrm10010mpAlmLineInputLossOfSignalPortnread-onlycurrentLine Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Line Trscv <Help> Alarm indicating a Loss of Signal is detected on the Line T…
1.3.6.1.4.1.20044.54.2.3.2.152.1.3Columnrm10010mpAlmLineLossOfFramePortnread-onlycurrentLine Loss Of Frame :This OID indicates the module is not aligned with the incoming Line signal <Help> Alarm indicating the module is not aligned with the incom…
1.3.6.1.4.1.20044.54.2.3.2.152.1.4Columnrm10010mpAlmLineSmBdiInsertedPortnread-onlycurrentLine SM BDI Inserted :This OID indicates a SM Backward Defect Indication is inserted on the outgoing Line signal <Help> Status indicating a SM Backward Defect …
1.3.6.1.4.1.20044.54.2.3.2.152.1.5Columnrm10010mpAlmLineSmBdiDetectedPortnread-onlycurrentLine SM BDI Detected :This OID indicates a SM Backward Defect Indication is detected on the incoming Line signal <Help> Alarm indicating a SM Backward Defect I…
1.3.6.1.4.1.20044.54.2.3.2.152.1.6Columnrm10010mpAlmLineSmIaeInsertedPortnread-onlycurrentLine SM IAE Inserted :This OID indicates a SM Incoming Alignment Error is inserted on the outgoing Line signal <Help> Status indicating a SM Incoming Alignment…
1.3.6.1.4.1.20044.54.2.3.2.152.1.7Columnrm10010mpAlmLineSmIaeDetectedPortnread-onlycurrentLine SM IAE Detected :This OID indicates a SM Incoming Alignment Error is detected on the incoming Line signal <Help> Alarm indicating a SM Incoming Alignment …
1.3.6.1.4.1.20044.54.2.3.2.152.1.10Columnrm10010mpAlmLineTxHostLolPortnread-onlycurrentLine Host Lane Tx Loss Of Lock :This OID indicates a Tx Loss of Lock on the Line Trscv Host Lane <Help> Alarm indicating a Tx Loss of Lock on the Line Trscv Ho…
1.3.6.1.4.1.20044.54.2.3.2.152.1.11Columnrm10010mpAlmLineLaneTxFifoErrorPortnread-onlycurrentLine Host Lane Tx FIFO Error :This OID indicates a Tx FIFO Error on the Line Trscv Host Lane <Help> Alarm indicating a Tx FIFO Error on the Line Trscv Host Lan…
1.3.6.1.4.1.20044.54.2.3.2.168Tablerm10010mpAlmlineNetworkLaneRxOtnTablenot-accessiblecurrentList of rm10010mpAlmlineNetworkLaneRxOtn Article
1.3.6.1.4.1.20044.54.2.3.2.168.1Rowrm10010mpAlmlineNetworkLaneRxOtnEntrynot-accessiblecurrentRow definition for the rm10010mpAlmlineNetworkLaneRxOtn table
1.3.6.1.4.1.20044.54.2.3.2.168.1.1Columnrm10010mpAlmlineNetworkLaneRxOtnIndexread-onlycurrentIndex definition for the rm10010mpAlmlineNetworkLaneRxOtn table
1.3.6.1.4.1.20044.54.2.3.2.168.1.10Columnrm10010mpAlmLineRxOtnOduAisPortnread-onlycurrentLine Network Rx ODU AIS :This OID indicates an ODU This OID Indication Signal is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating…
1.3.6.1.4.1.20044.54.2.3.2.168.1.11Columnrm10010mpAlmLineRxOtnOtuAisPortnread-onlycurrentLine Network Rx OTU AIS :This OID indicates an OTU This OID Indication Signal is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating…
1.3.6.1.4.1.20044.54.2.3.2.168.1.12Columnrm10010mpAlmLineRxSmBdiPortnread-onlycurrentLine Network Rx SM BDI :This OID indicates an SM Backward Defect Indication is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating a…
1.3.6.1.4.1.20044.54.2.3.2.168.1.13Columnrm10010mpAlmLineRxOtnIaePortnread-onlycurrentLine Network Rx IAE :This OID indicates an Incoming Alignment Error is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating an Incomi…
1.3.6.1.4.1.20044.54.2.3.2.168.1.14Columnrm10010mpAlmLineRxOtnOomPortnread-onlycurrentLine Network Rx OOM :This OID indicates an Out of Multiframe is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating an Out of Multif…
1.3.6.1.4.1.20044.54.2.3.2.168.1.15Columnrm10010mpAlmLineRxOtnLomPortnread-onlycurrentLine Network Rx LOM :This OID indicates a Loss of Multiframe is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating a Loss of Multif…
1.3.6.1.4.1.20044.54.2.3.2.168.1.16Columnrm10010mpAlmLineRxOtnOofPortnread-onlycurrentLine Network Rx OOF :This OID indicates an Out of Frame is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating an Out of Frame is de…
1.3.6.1.4.1.20044.54.2.3.2.168.1.17Columnrm10010mpAlmLineRxOtnLofPortnread-onlycurrentLine Network Rx LOF :This OID indicates a Loss of Frame is detected on the Rx Network interface of the Line Trscv <Help> Alarm indicating a Loss of Frame is de…
1.3.6.1.4.1.20044.54.2.3.2.184Tablerm10010mpAlmlineHostLaneTxOtnTablenot-accessiblecurrentList of rm10010mpAlmlineHostLaneTxOtn Article
1.3.6.1.4.1.20044.54.2.3.2.184.1Rowrm10010mpAlmlineHostLaneTxOtnEntrynot-accessiblecurrentRow definition for the rm10010mpAlmlineHostLaneTxOtn table
1.3.6.1.4.1.20044.54.2.3.2.184.1.1Columnrm10010mpAlmlineHostLaneTxOtnIndexread-onlycurrentIndex definition for the rm10010mpAlmlineHostLaneTxOtn table
1.3.6.1.4.1.20044.54.2.3.2.184.1.10Columnrm10010mpAlmLineTxOtnOduAisPortnread-onlycurrentLine Host Tx ODU AIS :This OID indicates an ODU This OID Indication Signal is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an OD…
1.3.6.1.4.1.20044.54.2.3.2.184.1.11Columnrm10010mpAlmLineTxOtnOtuAisPortnread-onlycurrentLine Host Tx OTU AIS :This OID indicates an OTU This OID Indication Signal is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an OT…
1.3.6.1.4.1.20044.54.2.3.2.184.1.12Columnrm10010mpAlmLineTxSmBdiPortnread-onlycurrentLine Host Tx SM BDI :This OID indicates an SM Backward Defect Indication is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an SM B…
1.3.6.1.4.1.20044.54.2.3.2.184.1.13Columnrm10010mpAlmLineTxOtnIaePortnread-onlycurrentLine Host Tx IAE :This OID indicates an Incoming Alignment Error is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an Incoming Ali…
1.3.6.1.4.1.20044.54.2.3.2.184.1.14Columnrm10010mpAlmLineTxOtnOomPortnread-onlycurrentLine Host Tx OOM :This OID indicates an Out of Multiframe is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an Out of Multiframe i…
1.3.6.1.4.1.20044.54.2.3.2.184.1.15Columnrm10010mpAlmLineTxOtnLomPortnread-onlycurrentLine Host Tx LOM :This OID indicates a Loss of Multiframe is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating a Loss of Multiframe i…
1.3.6.1.4.1.20044.54.2.3.2.184.1.16Columnrm10010mpAlmLineTxOtnOofPortnread-onlycurrentLine Host Tx OOF :This OID indicates an Out of Frame is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating an Out of Frame is detected…
1.3.6.1.4.1.20044.54.2.3.2.184.1.17Columnrm10010mpAlmLineTxOtnLofPortnread-onlycurrentLine Host Tx LOF :This OID indicates a Loss of Frame is detected on the Tx Host interface of the Line Trscv <Help> Alarm indicating a Loss of Frame is detected…
1.3.6.1.4.1.20044.54.2.3.3Noderm10010mpAlmLineCrit
1.3.6.1.4.1.20044.54.2.3.3.24Tablerm10010mpAlmsynthAlmLineTablenot-accessiblecurrentList of rm10010mpAlmsynthAlmLine Article
1.3.6.1.4.1.20044.54.2.3.3.24.1Rowrm10010mpAlmsynthAlmLineEntrynot-accessiblecurrentRow definition for the rm10010mpAlmsynthAlmLine table
1.3.6.1.4.1.20044.54.2.3.3.24.1.1Columnrm10010mpAlmsynthAlmLineIndexread-onlycurrentIndex definition for the rm10010mpAlmsynthAlmLine table
1.3.6.1.4.1.20044.54.2.3.3.24.1.2Columnrm10010mpAlmXfpAbsentPortnread-onlycurrentLine Optical Module Absent :This OID indicates that the line optical interface is not present. <Help> This alarm indicates if the line transceiver is not plugg…
1.3.6.1.4.1.20044.54.2.3.3.24.1.3Columnrm10010mpAlmXfpInitNotComplPortnread-onlycurrentLine Optical Module Ready :This OID indicates that the optical interface is not operational. <Help> This status indicates if the line transceiver has been corr…
1.3.6.1.4.1.20044.54.2.3.3.24.1.5Columnrm10010mpAlmLineHwFailPortnread-onlycurrentLine Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Help> This alarm indicates a failure on line port, most pr…
1.3.6.1.4.1.20044.54.2.3.3.24.1.6Columnrm10010mpAlmXfpTxOffPortnread-onlycurrentLine Trscv Laser Shutdown :This OID indicates the Line transceiver laser is shutdown <Help> This status indicates if the Line transceiver laser is shutdown <Co…
1.3.6.1.4.1.20044.54.2.3.3.24.1.7Columnrm10010mpAlmLineLocalOosPortnread-onlycurrentLine Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service…
1.3.6.1.4.1.20044.54.2.3.3.24.1.9Columnrm10010mpAlmUpRdiInsPortnread-onlycurrentMS-RDI/L-RDI Inserted On Line :This OID indicates an upstream MS-RDI/L-RDI has been inserted in the outgoing 10 Gb/s SDH/SONET signal. <Help> This status indic…
1.3.6.1.4.1.20044.54.2.3.3.24.1.10Columnrm10010mpAlmLineDdmWarningPortnread-onlycurrentWarning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Warning has…
1.3.6.1.4.1.20044.54.2.3.3.24.1.11Columnrm10010mpAlmLineDdmAlmPortnread-onlycurrentAlarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Alarm has been…
1.3.6.1.4.1.20044.54.2.3.3.24.1.13Columnrm10010mpAlmLineFailPortnread-onlycurrentLine Port Failure :This OID indicates a failure on the line port <Help> This alarm indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipm…
1.3.6.1.4.1.20044.54.2.3.3.24.1.17Columnrm10010mpAlmLineActivePortnread-onlycurrentLine Active :This OID indicates whether the line is active or standby. <Help> This status indicates whether the line is active or standby. <Condtype> LINE_ACTI…
1.3.6.1.4.1.20044.54.3Noderm10010mpmeasures
1.3.6.1.4.1.20044.54.3.1Noderm10010mpMesrOther
1.3.6.1.4.1.20044.54.3.1.0Scalarrm10010mpMesrsynth0read-onlydeprecatedNot Used :
1.3.6.1.4.1.20044.54.3.1.1Scalarrm10010mpMesrsynth1read-onlydeprecatedNot Used :
1.3.6.1.4.1.20044.54.3.1.7Scalarrm10010mpMesrpmIntervalNumberread-onlycurrentPM Interval Counter :
1.3.6.1.4.1.20044.54.3.1.180Scalarrm10010mpMesrlineNetTxLaserOutputPwrAverageread-onlycurrentAverage Line Trscv Tx Power :This OID gives the average Tx Laser transmit power value among the network lanes of the Line Transceiver, read in the DDM (Digital…
1.3.6.1.4.1.20044.54.3.1.181Scalarrm10010mpMesrlineNetTxLaserTempAverageread-onlycurrentAverage Line Trscv Tx Laser Temperature :This OID gives the average Tx Laser Temperature value among the network lanes of the Line Transceiver, read from the D…
1.3.6.1.4.1.20044.54.3.1.182Scalarrm10010mpMesrlineNetTxBiasCurrentAverageread-onlycurrentAverage Line Trscv Tx Laser Bias :This OID gives the average Tx Laser Bias value among the network lanes of the Line Transceiver, read from the DDM (Digital Di…
1.3.6.1.4.1.20044.54.3.1.183Scalarrm10010mpMesrlineNetRxInputPwrAverageread-onlycurrentAverage Line Trscv Rx Power :This OID gives the average Receive power value among the network lanes of the Line Transceiver, read in the DDM (Digital Diagnosti…
1.3.6.1.4.1.20044.54.3.1.184Scalarrm10010mpMesrlineResidualChromaticDispAverageread-onlycurrentAverage Residual Chromatic Dispersion :This OID gives the average Residual Chromatic Dispersion on the Line interface since the last measure reset <Help> This …
1.3.6.1.4.1.20044.54.3.1.185Scalarrm10010mpMesrlineDiffGroupDelayAverageread-onlycurrentAverage Differential Group Delay :This OID gives the average Group Delay on the Line interface since the last measure reset <Help> This measure gives the avera…
1.3.6.1.4.1.20044.54.3.1.186Scalarrm10010mpMesrlineQFactorAverageread-onlycurrentAverage Q Factor :This OID gives the average Q Factor on the Line interface since the last measure reset <Help> This measure gives the average Q Factor on the …
1.3.6.1.4.1.20044.54.3.1.187Scalarrm10010mpMesrlineCarrierFreqOffsetAverageread-onlycurrentAverage Carrier Frequency Offset :This OID gives the average Carrier Frequency Offset on the Line interface since the last measure reset <Help> This measure gi…
1.3.6.1.4.1.20044.54.3.1.188Scalarrm10010mpMesrlineOsnrAverageread-onlycurrentAverage OSNR :This OID gives the average OSNR on the Line interface since the last measure reset <Help> This measure gives the average OSNR on the Line interfa…
1.3.6.1.4.1.20044.54.3.1.192Scalarrm10010mpMesrclientNetTxTempMinread-onlycurrentMin Client Trscv Laser Temperature :This OID gives the minimum Laser temperature value among the network lanes of the Client Transceiver, read from the DDM (Di…
1.3.6.1.4.1.20044.54.3.1.193Scalarrm10010mpMesrclientNetTxBiasMinread-onlycurrentMin Client Trscv Laser Bias :This OID gives the minimum Laser bias value among the network lanes of the Client Transceiver, read from the DDM (Digital Diagnost…
1.3.6.1.4.1.20044.54.3.1.194Scalarrm10010mpMesrclientNetTxPwrMinread-onlycurrentMin Client Trscv Tx Power :This OID gives the minimum transmit power value among the network lanes of the Client Transceiver, read from the DDM (Digital Diagno…
1.3.6.1.4.1.20044.54.3.1.195Scalarrm10010mpMesrclientNetRxPwrMinread-onlycurrentMin Client Trscv Rx Power :This OID gives the minimum receive power value among the network lanes of the Client Transceiver, read in the DDM (Digital Diagnosti…
1.3.6.1.4.1.20044.54.3.1.196Scalarrm10010mpMesrlineNetTxLaserOutputPwrMinread-onlycurrentMin Line Trscv Tx Power :This OID gives the minimum Tx Laser transmit power value among the network lanes of the Line Transceiver, read in the DDM (Digital Dia…
1.3.6.1.4.1.20044.54.3.1.197Scalarrm10010mpMesrlineNetTxLaserTempMinread-onlycurrentMin Line Trscv Tx Laser Temperature :This OID gives the minimum Tx Laser Temperature value among the network lanes of the Line Transceiver, read from the DDM (…
1.3.6.1.4.1.20044.54.3.1.198Scalarrm10010mpMesrlineNetTxBiasCurrentMinread-onlycurrentMin Line Trscv Tx Laser Bias :This OID gives the minimum Tx Laser Bias value among the network lanes of the Line Transceiver, read from the DDM (Digital Diagno…
1.3.6.1.4.1.20044.54.3.1.199Scalarrm10010mpMesrlineNetRxInputPwrMinread-onlycurrentMin Line Trscv Rx Power :This OID gives the minimum Receive power value among the network lanes of the Line Transceiver, read in the DDM (Digital Diagnostic Mo…
1.3.6.1.4.1.20044.54.3.1.200Scalarrm10010mpMesrlineResidualChromaticDispMinread-onlycurrentMin Residual Chromatic Dispersion :This OID gives the minimum Residual Chromatic Dispersion on the Line interface since the last measure reset (Unit = ps/nm)<H…
1.3.6.1.4.1.20044.54.3.1.201Scalarrm10010mpMesrlineDiffGroupDelayMinread-onlycurrentMin Differential Group Delay :This OID gives the minimum Differential Group Delay on the Line interface since the last measure reset (Unit = ps)<Help> This mea…
1.3.6.1.4.1.20044.54.3.1.202Scalarrm10010mpMesrlineQFactorMinread-onlycurrentMin Q Factor :This OID gives the minimum Q Factor on the Line interface since the last measure reset (Unit = dB)<Help> This measure gives the minimum Q Factor …
1.3.6.1.4.1.20044.54.3.1.203Scalarrm10010mpMesrlineCarrierFreqOffsetMinread-onlycurrentMin Carrier Frequency Offset :This OID gives the minimum Carrier Frequency Offset on the Line interface since the last measure reset (Unit = Mhz)<Help> This me…
1.3.6.1.4.1.20044.54.3.1.204Scalarrm10010mpMesrlineOsnrMinread-onlycurrentMin OSNR :This OID gives the minimum OSNR on the Line interface since the last measure reset (OSNR = AV/10) (Unit = dB)<Help> This measure gives the minimum OS…
1.3.6.1.4.1.20044.54.3.1.208Scalarrm10010mpMesrclientNetTxTempMaxread-onlycurrentMax Client Trscv Laser Temperature :This OID gives the maximum Laser temperature value among the network lanes of the Client Transceiver, read from the DDM (Di…
1.3.6.1.4.1.20044.54.3.1.209Scalarrm10010mpMesrclientNetTxBiasMaxread-onlycurrentMax Client Trscv Laser Bias :This OID gives the maximum Laser bias value among the network lanes of the Client Transceiver, read from the DDM (Digital Diagnost…
1.3.6.1.4.1.20044.54.3.1.210Scalarrm10010mpMesrclientNetTxPwrMaxread-onlycurrentMax Client Trscv Tx Power :This OID gives the maximum transmit power value among the network lanes of the Client Transceiver, read from the DDM (Digital Diagno…
1.3.6.1.4.1.20044.54.3.1.211Scalarrm10010mpMesrclientNetRxPwrMaxread-onlycurrentMax Client Trscv Rx Power :This OID gives the maximum receive power value among the network lanes of the Client Transceiver, read in the DDM (Digital Diagnosti…
1.3.6.1.4.1.20044.54.3.1.212Scalarrm10010mpMesrlineNetTxLaserOutputPwrMaxread-onlycurrentMax Line Trscv Tx Power :This OID gives the maximum Tx Laser transmit power value among the network lanes of the Line Transceiver, read in the DDM (Digital Dia…
1.3.6.1.4.1.20044.54.3.1.213Scalarrm10010mpMesrlineNetTxLaserTempMaxread-onlycurrentMax Line Trscv Tx Laser Temperature :This OID gives the maximum Tx Laser Temperature value among the network lanes of the Line Transceiver, read from the DDM (…
1.3.6.1.4.1.20044.54.3.1.214Scalarrm10010mpMesrlineNetTxBiasCurrentMaxread-onlycurrentMax Line Trscv Tx Laser Bias :This OID gives the maximum Tx Laser Bias value among the network lanes of the Line Transceiver, read from the DDM (Digital Diagno…
1.3.6.1.4.1.20044.54.3.1.215Scalarrm10010mpMesrlineNetRxInputPwrMaxread-onlycurrentMax Line Trscv Rx Power :This OID gives the maximum Receive power value among the network lanes of the Line Transceiver, read in the DDM (Digital Diagnostic Mo…
1.3.6.1.4.1.20044.54.3.1.216Scalarrm10010mpMesrlineResidualChromaticDispMaxread-onlycurrentMax Residual Chromatic Dispersion :This OID gives the maximum Residual Chromatic Dispersion on the Line interface since the last measure reset (Unit = ps/nm)<H…
1.3.6.1.4.1.20044.54.3.1.217Scalarrm10010mpMesrlineDiffGroupDelayMaxread-onlycurrentMax Differential Group Delay :This OID gives the maximum Differential Group Delay on the Line interface since the last measure reset (Unit = ps)<Help> This mea…
1.3.6.1.4.1.20044.54.3.1.218Scalarrm10010mpMesrlineQFactorMaxread-onlycurrentMax Q Factor :This OID gives the maximum Q Factor on the Line interface since the last measure reset (Unit = dB)<Help> This measure gives the maximum Q Factor …
1.3.6.1.4.1.20044.54.3.1.219Scalarrm10010mpMesrlineCarrierFreqOffsetMaxread-onlycurrentMax Carrier Frequency Offset :This OID gives the maximum Carrier Frequency Offset on the Line interface since the last measure reset (Unit = Mhz)<Help> This me…
1.3.6.1.4.1.20044.54.3.1.220Scalarrm10010mpMesrlineOsnrMaxread-onlycurrentMax OSNR :This OID gives the maximum OSNR on the Line interface since the last measure reset (OSNR = AV/10) (Unit = dB)<Help> This measure gives the maximum OS…
1.3.6.1.4.1.20044.54.3.2Noderm10010mpMesrClient
1.3.6.1.4.1.20044.54.3.2.8Scalarrm10010mpMesrclientCfpTempread-onlycurrentClient Trscv Temperature :This OID gives the temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/2…
1.3.6.1.4.1.20044.54.3.2.9Scalarrm10010mpMesrclientCfp3v3Voltageread-onlycurrentClient Trscv Voltage :This OID gives the 3V3 voltage value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/1000) (Un…
1.3.6.1.4.1.20044.54.3.2.10Scalarrm10010mpMesrclientSoaBiasCurrentread-onlycurrentClient Trscv SOA Bias :This OID gives the SOA bias value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = m…
1.3.6.1.4.1.20044.54.3.2.16Tablerm10010mpMesrclientNetTxTempTablenot-accessiblecurrentList of rm10010mpMesrclientNetTxTemp Article
1.3.6.1.4.1.20044.54.3.2.16.1Rowrm10010mpMesrclientNetTxTempEntrynot-accessiblecurrentRow definition for the rm10010mpMesrclientNetTxTemp table
1.3.6.1.4.1.20044.54.3.2.16.1.1Columnrm10010mpMesrclientNetTxTempIndexread-onlycurrentIndex definition for the rm10010mpMesrclientNetTxTemp table
1.3.6.1.4.1.20044.54.3.2.16.1.2Columnrm10010mpMesrclientNetTxTempPortnread-onlycurrentClient Trscv Temperature :This OID gives the Laser temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature …
1.3.6.1.4.1.20044.54.3.2.32Tablerm10010mpMesrclientNetTxBiasTablenot-accessiblecurrentList of rm10010mpMesrclientNetTxBias Article
1.3.6.1.4.1.20044.54.3.2.32.1Rowrm10010mpMesrclientNetTxBiasEntrynot-accessiblecurrentRow definition for the rm10010mpMesrclientNetTxBias table
1.3.6.1.4.1.20044.54.3.2.32.1.1Columnrm10010mpMesrclientNetTxBiasIndexread-onlycurrentIndex definition for the rm10010mpMesrclientNetTxBias table
1.3.6.1.4.1.20044.54.3.2.32.1.2Columnrm10010mpMesrclientNetTxBiasPortnread-onlycurrentClient Trscv Laser Bias :This OID gives the Laser bias value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit…
1.3.6.1.4.1.20044.54.3.2.48Tablerm10010mpMesrclientNetTxPwrTablenot-accessiblecurrentList of rm10010mpMesrclientNetTxPwr Article
1.3.6.1.4.1.20044.54.3.2.48.1Rowrm10010mpMesrclientNetTxPwrEntrynot-accessiblecurrentRow definition for the rm10010mpMesrclientNetTxPwr table
1.3.6.1.4.1.20044.54.3.2.48.1.1Columnrm10010mpMesrclientNetTxPwrIndexread-onlycurrentIndex definition for the rm10010mpMesrclientNetTxPwr table
1.3.6.1.4.1.20044.54.3.2.48.1.2Columnrm10010mpMesrclientNetTxPwrPortnread-onlycurrentClient Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)…
1.3.6.1.4.1.20044.54.3.2.64Tablerm10010mpMesrclientNetRxPwrTablenot-accessiblecurrentList of rm10010mpMesrclientNetRxPwr Article
1.3.6.1.4.1.20044.54.3.2.64.1Rowrm10010mpMesrclientNetRxPwrEntrynot-accessiblecurrentRow definition for the rm10010mpMesrclientNetRxPwr table
1.3.6.1.4.1.20044.54.3.2.64.1.1Columnrm10010mpMesrclientNetRxPwrIndexread-onlycurrentIndex definition for the rm10010mpMesrclientNetRxPwr table
1.3.6.1.4.1.20044.54.3.2.64.1.2Columnrm10010mpMesrclientNetRxPwrPortnread-onlycurrentClient Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40…
1.3.6.1.4.1.20044.54.3.3Noderm10010mpMesrLine
1.3.6.1.4.1.20044.54.3.3.12Scalarrm10010mpMesrlineMsaTempread-onlycurrentLine Trscv Temperature :This OID gives the temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) …
1.3.6.1.4.1.20044.54.3.3.13Scalarrm10010mpMesrlineMsa3v3Voltageread-onlycurrentLine Trscv Voltage :This OID gives the 3V3 voltage value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/1000) (Unit =…
1.3.6.1.4.1.20044.54.3.3.14Scalarrm10010mpMesrlineSoaBiasCurrentread-onlycurrentLine Trscv SOA Bias :This OID gives the SOA bias value of the Line Transceiver,read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <H…
1.3.6.1.4.1.20044.54.3.3.80Tablerm10010mpMesrlineNetTxLaserOutputPwrTablenot-accessiblecurrentList of rm10010mpMesrlineNetTxLaserOutputPwr Article
1.3.6.1.4.1.20044.54.3.3.80.1Rowrm10010mpMesrlineNetTxLaserOutputPwrEntrynot-accessiblecurrentRow definition for the rm10010mpMesrlineNetTxLaserOutputPwr table
1.3.6.1.4.1.20044.54.3.3.80.1.1Columnrm10010mpMesrlineNetTxLaserOutputPwrIndexread-onlycurrentIndex definition for the rm10010mpMesrlineNetTxLaserOutputPwr table
1.3.6.1.4.1.20044.54.3.3.80.1.2Columnrm10010mpMesrlineNetTxLaserOutputPwrPortnread-onlycurrentCurrent Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power =…
1.3.6.1.4.1.20044.54.3.3.96Tablerm10010mpMesrlineNetTxLaserTempTablenot-accessiblecurrentList of rm10010mpMesrlineNetTxLaserTemp Article
1.3.6.1.4.1.20044.54.3.3.96.1Rowrm10010mpMesrlineNetTxLaserTempEntrynot-accessiblecurrentRow definition for the rm10010mpMesrlineNetTxLaserTemp table
1.3.6.1.4.1.20044.54.3.3.96.1.1Columnrm10010mpMesrlineNetTxLaserTempIndexread-onlycurrentIndex definition for the rm10010mpMesrlineNetTxLaserTemp table
1.3.6.1.4.1.20044.54.3.3.96.1.2Columnrm10010mpMesrlineNetTxLaserTempPortnread-onlycurrentCurrent Line Trscv Tx Laser Temperature :This OID gives the Tx Laser Temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitorin…
1.3.6.1.4.1.20044.54.3.3.112Tablerm10010mpMesrlineNetTxBiasCurrentTablenot-accessiblecurrentList of rm10010mpMesrlineNetTxBiasCurrent Article
1.3.6.1.4.1.20044.54.3.3.112.1Rowrm10010mpMesrlineNetTxBiasCurrentEntrynot-accessiblecurrentRow definition for the rm10010mpMesrlineNetTxBiasCurrent table
1.3.6.1.4.1.20044.54.3.3.112.1.1Columnrm10010mpMesrlineNetTxBiasCurrentIndexread-onlycurrentIndex definition for the rm10010mpMesrlineNetTxBiasCurrent table
1.3.6.1.4.1.20044.54.3.3.112.1.2Columnrm10010mpMesrlineNetTxBiasCurrentPortnread-onlycurrentCurrent Line Trscv Tx Laser Bias :This OID gives the Tx Laser Bias value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/…
1.3.6.1.4.1.20044.54.3.3.128Tablerm10010mpMesrlineNetRxInputPwrTablenot-accessiblecurrentList of rm10010mpMesrlineNetRxInputPwr Article
1.3.6.1.4.1.20044.54.3.3.128.1Rowrm10010mpMesrlineNetRxInputPwrEntrynot-accessiblecurrentRow definition for the rm10010mpMesrlineNetRxInputPwr table
1.3.6.1.4.1.20044.54.3.3.128.1.1Columnrm10010mpMesrlineNetRxInputPwrIndexread-onlycurrentIndex definition for the rm10010mpMesrlineNetRxInputPwr table
1.3.6.1.4.1.20044.54.3.3.128.1.2Columnrm10010mpMesrlineNetRxInputPwrPortnread-onlycurrentCurrent Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (…
1.3.6.1.4.1.20044.54.3.3.144Tablerm10010mpMesrlineResidualChromaticDispTablenot-accessiblecurrentList of rm10010mpMesrlineResidualChromaticDisp Article
1.3.6.1.4.1.20044.54.3.3.144.1Rowrm10010mpMesrlineResidualChromaticDispEntrynot-accessiblecurrentRow definition for the rm10010mpMesrlineResidualChromaticDisp table
1.3.6.1.4.1.20044.54.3.3.144.1.1Columnrm10010mpMesrlineResidualChromaticDispIndexread-onlycurrentIndex definition for the rm10010mpMesrlineResidualChromaticDisp table
1.3.6.1.4.1.20044.54.3.3.144.1.2Columnrm10010mpMesrlineResidualChromaticDispPortnread-onlycurrentCurrent Residual Chromatic Dispersion :This OID gives the current Residual Chromatic Dispersion on the Line interface (Unit = ps/nm)<Help> This measure gives t…
1.3.6.1.4.1.20044.54.3.3.148Tablerm10010mpMesrlineDiffGroupDelayTablenot-accessiblecurrentList of rm10010mpMesrlineDiffGroupDelay Article
1.3.6.1.4.1.20044.54.3.3.148.1Rowrm10010mpMesrlineDiffGroupDelayEntrynot-accessiblecurrentRow definition for the rm10010mpMesrlineDiffGroupDelay table
1.3.6.1.4.1.20044.54.3.3.148.1.1Columnrm10010mpMesrlineDiffGroupDelayIndexread-onlycurrentIndex definition for the rm10010mpMesrlineDiffGroupDelay table
1.3.6.1.4.1.20044.54.3.3.148.1.2Columnrm10010mpMesrlineDiffGroupDelayPortnread-onlycurrentCurrent Differential Group Delay :This OID gives the current Differential Group Delay on the Line interface (Unit = ps)<Help> This measure gives the current Di…
1.3.6.1.4.1.20044.54.3.3.152Tablerm10010mpMesrlineQFactorTablenot-accessiblecurrentList of rm10010mpMesrlineQFactor Article
1.3.6.1.4.1.20044.54.3.3.152.1Rowrm10010mpMesrlineQFactorEntrynot-accessiblecurrentRow definition for the rm10010mpMesrlineQFactor table
1.3.6.1.4.1.20044.54.3.3.152.1.1Columnrm10010mpMesrlineQFactorIndexread-onlycurrentIndex definition for the rm10010mpMesrlineQFactor table
1.3.6.1.4.1.20044.54.3.3.152.1.2Columnrm10010mpMesrlineQFactorPortnread-onlycurrentCurrent Q Factor :This OID gives the current Q Factor on the Line interface (Unit = dB) <Help> This measure gives the current Q Factor on the Line interface.
1.3.6.1.4.1.20044.54.3.3.156Tablerm10010mpMesrlineCarrierFreqOffsetTablenot-accessiblecurrentList of rm10010mpMesrlineCarrierFreqOffset Article
1.3.6.1.4.1.20044.54.3.3.156.1Rowrm10010mpMesrlineCarrierFreqOffsetEntrynot-accessiblecurrentRow definition for the rm10010mpMesrlineCarrierFreqOffset table
1.3.6.1.4.1.20044.54.3.3.156.1.1Columnrm10010mpMesrlineCarrierFreqOffsetIndexread-onlycurrentIndex definition for the rm10010mpMesrlineCarrierFreqOffset table
1.3.6.1.4.1.20044.54.3.3.156.1.2Columnrm10010mpMesrlineCarrierFreqOffsetPortnread-onlycurrentCurrent Carrier Frequency Offset :This OID gives the current Carrier Frequency Offset on the Line interface (Unit = Mhz)<Help> This measure gives the current C…
1.3.6.1.4.1.20044.54.3.3.160Tablerm10010mpMesrlineOsnrTablenot-accessiblecurrentList of rm10010mpMesrlineOsnr Article
1.3.6.1.4.1.20044.54.3.3.160.1Rowrm10010mpMesrlineOsnrEntrynot-accessiblecurrentRow definition for the rm10010mpMesrlineOsnr table
1.3.6.1.4.1.20044.54.3.3.160.1.1Columnrm10010mpMesrlineOsnrIndexread-onlycurrentIndex definition for the rm10010mpMesrlineOsnr table
1.3.6.1.4.1.20044.54.3.3.160.1.2Columnrm10010mpMesrlineOsnrPortnread-onlycurrentCurrent OSNR :This OID gives the current OSNR on the Line interface (OSNR = AV/10) (Unit = dB)<Help> This measure gives the current OSNR on the Line interface.
1.3.6.1.4.1.20044.54.4Noderm10010mpcounters
1.3.6.1.4.1.20044.54.4.1Noderm10010mpCntOther
1.3.6.1.4.1.20044.54.4.2Noderm10010mpCntClient
1.3.6.1.4.1.20044.54.4.2.16Tablerm10010mpCntclientInputErrorCounterLaneOneTablenot-accessiblecurrentList of rm10010mpCntclientInputErrorCounterLaneOne Article
1.3.6.1.4.1.20044.54.4.2.16.1Rowrm10010mpCntclientInputErrorCounterLaneOneEntrynot-accessiblecurrentRow definition for the rm10010mpCntclientInputErrorCounterLaneOne table
1.3.6.1.4.1.20044.54.4.2.16.1.1Columnrm10010mpCntclientInputErrorCounterLaneOneIndexread-onlycurrentIndex definition for the rm10010mpCntclientInputErrorCounterLaneOne table
1.3.6.1.4.1.20044.54.4.2.16.1.2Columnrm10010mpCntclientInputErrorCounterLaneOneValuePortnread-onlycurrentClient_Input_Error_Counter_Lane1 :This counter is incremented each time a coding violation is detected on the host lane of the client transceiver <Help> This c…
1.3.6.1.4.1.20044.54.4.2.16.1.3Columnrm10010mpCntclientInputErrorCounterLaneOneErrorPortnread-onlycurrentClient Input Counter Error :This OID when set indicates the rate adaptation removal counter value is invalid on Port
1.3.6.1.4.1.20044.54.4.2.16.1.4Columnrm10010mpCntclientInputErrorCounterLaneOneOverloadPortnread-onlycurrentClient Input Counter Overload :This OID when set indicates a rate adaptation removal counter overload on Port
1.3.6.1.4.1.20044.54.4.2.32Tablerm10010mpCntclientInputErrorCounterLaneTwoTablenot-accessiblecurrentList of rm10010mpCntclientInputErrorCounterLaneTwo Article
1.3.6.1.4.1.20044.54.4.2.32.1Rowrm10010mpCntclientInputErrorCounterLaneTwoEntrynot-accessiblecurrentRow definition for the rm10010mpCntclientInputErrorCounterLaneTwo table
1.3.6.1.4.1.20044.54.4.2.32.1.1Columnrm10010mpCntclientInputErrorCounterLaneTwoIndexread-onlycurrentIndex definition for the rm10010mpCntclientInputErrorCounterLaneTwo table
1.3.6.1.4.1.20044.54.4.2.32.1.2Columnrm10010mpCntclientInputErrorCounterLaneTwoValuePortnread-onlycurrentClient_Input_Error_Counter_Lane2 :This counter is incremented each time a coding violation is detected on the host lane of the client transceiver <Help> This c…
1.3.6.1.4.1.20044.54.4.2.32.1.3Columnrm10010mpCntclientInputErrorCounterLaneTwoErrorPortnread-onlycurrentClient Input Counter Error :This OID when set indicates the client error counter value is invalid on Port
1.3.6.1.4.1.20044.54.4.2.32.1.4Columnrm10010mpCntclientInputErrorCounterLaneTwoOverloadPortnread-onlycurrentClient Input Counter Overload :This OID when set indicates a client input error counter overload on Port
1.3.6.1.4.1.20044.54.4.2.80Tablerm10010mpCntclientInputErrorCounterTablenot-accessiblecurrentList of rm10010mpCntclientInputErrorCounter Article
1.3.6.1.4.1.20044.54.4.2.80.1Rowrm10010mpCntclientInputErrorCounterEntrynot-accessiblecurrentRow definition for the rm10010mpCntclientInputErrorCounter table
1.3.6.1.4.1.20044.54.4.2.80.1.1Columnrm10010mpCntclientInputErrorCounterIndexread-onlycurrentIndex definition for the rm10010mpCntclientInputErrorCounter table
1.3.6.1.4.1.20044.54.4.2.80.1.2Columnrm10010mpCntclientInputErrorCounterValuePortnread-onlycurrentClient Input Errors :This counter is increased each time a 10b/8b running disparity error is detected on the Client input stream <Help> This counter gives the …
1.3.6.1.4.1.20044.54.4.2.80.1.3Columnrm10010mpCntclientInputErrorCounterErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the client error counter value is invalid on Port
1.3.6.1.4.1.20044.54.4.2.80.1.4Columnrm10010mpCntclientInputErrorCounterOverloadPortnread-onlycurrentClient Counter Overload :This OID when set indicates a client input error counter overload on Port
1.3.6.1.4.1.20044.54.4.2.96Tablerm10010mpCntclientCbipCounterTablenot-accessiblecurrentList of rm10010mpCntclientCbipCounter Article
1.3.6.1.4.1.20044.54.4.2.96.1Rowrm10010mpCntclientCbipCounterEntrynot-accessiblecurrentRow definition for the rm10010mpCntclientCbipCounter table
1.3.6.1.4.1.20044.54.4.2.96.1.1Columnrm10010mpCntclientCbipCounterIndexread-onlycurrentIndex definition for the rm10010mpCntclientCbipCounter table
1.3.6.1.4.1.20044.54.4.2.96.1.2Columnrm10010mpCntclientCbipCounterValuePortnread-onlycurrentClient Output Errors :This counter is incremented each time a CBIP parity error is detected on the Client output stream <Help> This counter gives the number of…
1.3.6.1.4.1.20044.54.4.2.96.1.3Columnrm10010mpCntclientCbipCounterErrorPortnread-onlycurrentClient Counter Error :This OID when set indicates the CBIP error counter value is invalid on Port
1.3.6.1.4.1.20044.54.4.2.96.1.4Columnrm10010mpCntclientCbipCounterOverloadPortnread-onlycurrentClient CBIP Counter Overload :This OID when set indicates a CBIP error counter overload on Port
1.3.6.1.4.1.20044.54.4.3Noderm10010mpCntLine
1.3.6.1.4.1.20044.54.4.3.192Tablerm10010mpCntlocalLineSmBip8ErrorCounterTablenot-accessiblecurrentList of rm10010mpCntlocalLineSmBip8ErrorCounter Article
1.3.6.1.4.1.20044.54.4.3.192.1Rowrm10010mpCntlocalLineSmBip8ErrorCounterEntrynot-accessiblecurrentRow definition for the rm10010mpCntlocalLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.54.4.3.192.1.1Columnrm10010mpCntlocalLineSmBip8ErrorCounterIndexread-onlycurrentIndex definition for the rm10010mpCntlocalLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.54.4.3.192.1.2Columnrm10010mpCntlocalLineSmBip8ErrorCounterValuePortnread-onlycurrentLine Input SM-BIP8 Errors :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC <Help> This counter gives the current Bit Error Rate (r…
1.3.6.1.4.1.20044.54.4.3.192.1.3Columnrm10010mpCntlocalLineSmBip8ErrorCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the B1 error counter value is invalid on Port
1.3.6.1.4.1.20044.54.4.3.192.1.4Columnrm10010mpCntlocalLineSmBip8ErrorCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a B1 error counter overload on Port
1.3.6.1.4.1.20044.54.4.3.193Tablerm10010mpCntlocalLineFecCorrectedErrorsCounterTablenot-accessiblecurrentList of rm10010mpCntlocalLineFecCorrectedErrorsCounter Article
1.3.6.1.4.1.20044.54.4.3.193.1Rowrm10010mpCntlocalLineFecCorrectedErrorsCounterEntrynot-accessiblecurrentRow definition for the rm10010mpCntlocalLineFecCorrectedErrorsCounter table
1.3.6.1.4.1.20044.54.4.3.193.1.1Columnrm10010mpCntlocalLineFecCorrectedErrorsCounterIndexread-onlycurrentIndex definition for the rm10010mpCntlocalLineFecCorrectedErrorsCounter table
1.3.6.1.4.1.20044.54.4.3.193.1.2Columnrm10010mpCntlocalLineFecCorrectedErrorsCounterValuePortnread-onlycurrentLine Input HD FEC Corrected Errors :This OID gives the current Bit Error Rate before the Hard Decision FEC <Help> This counter gives the current Bit Error Rate…
1.3.6.1.4.1.20044.54.4.3.193.1.3Columnrm10010mpCntlocalLineFecCorrectedErrorsCounterErrorPortnread-onlycurrentFEC Counter Error :This bit when set indicates the FEC corrected errors counter value is invalid on Line
1.3.6.1.4.1.20044.54.4.3.193.1.4Columnrm10010mpCntlocalLineFecCorrectedErrorsCounterOverloadPortnread-onlycurrentFEC Counter Overload :This bit when set indicates a FEC corrected errors counter overload on Line
1.3.6.1.4.1.20044.54.4.3.194Tablerm10010mpCntremoteLineSmBip8ErrorCounterTablenot-accessiblecurrentList of rm10010mpCntremoteLineSmBip8ErrorCounter Article
1.3.6.1.4.1.20044.54.4.3.194.1Rowrm10010mpCntremoteLineSmBip8ErrorCounterEntrynot-accessiblecurrentRow definition for the rm10010mpCntremoteLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.54.4.3.194.1.1Columnrm10010mpCntremoteLineSmBip8ErrorCounterIndexread-onlycurrentIndex definition for the rm10010mpCntremoteLineSmBip8ErrorCounter table
1.3.6.1.4.1.20044.54.4.3.194.1.2Columnrm10010mpCntremoteLineSmBip8ErrorCounterValuePortnread-onlycurrentRemote SM BIP8 :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC on the remote side <Help> This counter gives the current Bit Error…
1.3.6.1.4.1.20044.54.4.3.194.1.3Columnrm10010mpCntremoteLineSmBip8ErrorCounterErrorPortnread-onlycurrentRemote Counter Error :
1.3.6.1.4.1.20044.54.4.3.194.1.4Columnrm10010mpCntremoteLineSmBip8ErrorCounterOverloadPortnread-onlycurrentRemote Counter Overload :
1.3.6.1.4.1.20044.54.4.3.195Tablerm10010mpCntlineDfrmTimCntTablenot-accessiblecurrentList of rm10010mpCntlineDfrmTimCnt Article
1.3.6.1.4.1.20044.54.4.3.195.1Rowrm10010mpCntlineDfrmTimCntEntrynot-accessiblecurrentRow definition for the rm10010mpCntlineDfrmTimCnt table
1.3.6.1.4.1.20044.54.4.3.195.1.1Columnrm10010mpCntlineDfrmTimCntIndexread-onlycurrentIndex definition for the rm10010mpCntlineDfrmTimCnt table
1.3.6.1.4.1.20044.54.4.3.195.1.2Columnrm10010mpCntlineDfrmTimCntValuePortnread-onlycurrentLine Timer Counter :
1.3.6.1.4.1.20044.54.4.3.195.1.3Columnrm10010mpCntlineDfrmTimCntErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.54.4.3.195.1.4Columnrm10010mpCntlineDfrmTimCntOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.54.4.3.196Tablerm10010mpCntlocalLineTrscvFecCorrectedErrorCounterTablenot-accessiblecurrentList of rm10010mpCntlocalLineTrscvFecCorrectedErrorCounter Article
1.3.6.1.4.1.20044.54.4.3.196.1Rowrm10010mpCntlocalLineTrscvFecCorrectedErrorCounterEntrynot-accessiblecurrentRow definition for the rm10010mpCntlocalLineTrscvFecCorrectedErrorCounter table
1.3.6.1.4.1.20044.54.4.3.196.1.1Columnrm10010mpCntlocalLineTrscvFecCorrectedErrorCounterIndexread-onlycurrentIndex definition for the rm10010mpCntlocalLineTrscvFecCorrectedErrorCounter table
1.3.6.1.4.1.20044.54.4.3.196.1.2Columnrm10010mpCntlocalLineTrscvFecCorrectedErrorCounterValuePortnread-onlycurrentLine Input SD FEC Corrected Errors :This OID gives the current Bit Error Rate before the Soft Decision FEC <Help> This counter gives the current Bit Error Rate…
1.3.6.1.4.1.20044.54.4.3.196.1.3Columnrm10010mpCntlocalLineTrscvFecCorrectedErrorCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.54.4.3.196.1.4Columnrm10010mpCntlocalLineTrscvFecCorrectedErrorCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.54.4.3.197Tablerm10010mpCntlocalLineTrscvFecUncorrectedErrorCounterTablenot-accessiblecurrentList of rm10010mpCntlocalLineTrscvFecUncorrectedErrorCounter Article
1.3.6.1.4.1.20044.54.4.3.197.1Rowrm10010mpCntlocalLineTrscvFecUncorrectedErrorCounterEntrynot-accessiblecurrentRow definition for the rm10010mpCntlocalLineTrscvFecUncorrectedErrorCounter table
1.3.6.1.4.1.20044.54.4.3.197.1.1Columnrm10010mpCntlocalLineTrscvFecUncorrectedErrorCounterIndexread-onlycurrentIndex definition for the rm10010mpCntlocalLineTrscvFecUncorrectedErrorCounter table
1.3.6.1.4.1.20044.54.4.3.197.1.2Columnrm10010mpCntlocalLineTrscvFecUncorrectedErrorCounterValuePortnread-onlycurrentSD Uncorrected :This OID gives the current Bit Error Rate after the Soft Decision FEC (residual) <Help> This counter gives the current Bit Error Rate after the…
1.3.6.1.4.1.20044.54.4.3.197.1.3Columnrm10010mpCntlocalLineTrscvFecUncorrectedErrorCounterErrorPortnread-onlycurrentLine Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.54.4.3.197.1.4Columnrm10010mpCntlocalLineTrscvFecUncorrectedErrorCounterOverloadPortnread-onlycurrentLine Counter Overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.54.6Noderm10010mpcontrolsWrite
1.3.6.1.4.1.20044.54.6.1Noderm10010mpCtrlOther
1.3.6.1.4.1.20044.54.6.1.1Noderm10010mpCtrlconfMgnt1
1.3.6.1.4.1.20044.54.6.1.1.1Scalarrm10010mpCtrlConf1Load1read-writecurrentLoad Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM.
1.3.6.1.4.1.20044.54.6.1.1.2Scalarrm10010mpCtrlConf2Load1read-writecurrentLoad Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM.
1.3.6.1.4.1.20044.54.6.1.1.10Scalarrm10010mpCtrlConf2Flash1read-writecurrentWrite Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura…
1.3.6.1.4.1.20044.54.6.1.1.14Scalarrm10010mpCtrlConf2Clear1read-writecurrentClear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o…
1.3.6.1.4.1.20044.54.6.1.4Noderm10010mpCtrlsynth4
1.3.6.1.4.1.20044.54.6.1.4.1Scalarrm10010mpCtrlCorrelatOnread-writecurrentEnable Alarm Correlation :This OID enables the alarm correlation in the PM.
1.3.6.1.4.1.20044.54.6.1.4.2Scalarrm10010mpCtrlCorrelatOffread-writecurrentDisable Alarm Correlation :This OID disables the alarm correlation in the PM.
1.3.6.1.4.1.20044.54.6.1.5Noderm10010mpCtrlswMgnt
1.3.6.1.4.1.20044.54.6.1.5.2Scalarrm10010mpCtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> …
1.3.6.1.4.1.20044.54.6.1.5.3Scalarrm10010mpCtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th…
1.3.6.1.4.1.20044.54.6.1.5.5Scalarrm10010mpCtrlLoadSwBank1read-writecurrentSet Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW…
1.3.6.1.4.1.20044.54.6.1.5.6Scalarrm10010mpCtrlLoadSwBank2read-writecurrentSet Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S…
1.3.6.1.4.1.20044.54.6.1.6Noderm10010mpCtrlgwMgnt
1.3.6.1.4.1.20044.54.6.1.6.1Scalarrm10010mpCtrlCurrentGwResetread-writecurrentActive Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting.
1.3.6.1.4.1.20044.54.6.1.6.5Scalarrm10010mpCtrlLoadGwBank1read-writecurrentSet Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.54.6.1.6.6Scalarrm10010mpCtrlLoadGwBank2read-writecurrentSet Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.54.6.1.6.7Scalarrm10010mpCtrlLoadGwBank3read-writecurrentSet Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.54.6.1.6.8Scalarrm10010mpCtrlLoadGwBank4read-writecurrentSet Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.54.6.1.192Noderm10010mpCtrlledTest
1.3.6.1.4.1.20044.54.6.1.192.1Scalarrm10010mpCtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.54.6.1.192.2Scalarrm10010mpCtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.54.6.1.192.3Scalarrm10010mpCtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.54.6.1.201Noderm10010mpCtrlinitSwitchMarvell
1.3.6.1.4.1.20044.54.6.1.201.1Scalarrm10010mpCtrlInitSwitchMarvellread-writecurrentSwitch Initialization :This OID operates an initialization of the switch managed through the module <Help> This control activates an initialization of the swit…
1.3.6.1.4.1.20044.54.6.1.259Noderm10010mpCtrlresetCount
1.3.6.1.4.1.20044.54.6.1.259.1Scalarrm10010mpCtrlResetcountread-writecurrentModule Count Global Reset :This OID resets all the errors counters on the module <Help > This control initiates a reset of the errors counters on the module
1.3.6.1.4.1.20044.54.6.1.260Noderm10010mpCtrlresetRmon
1.3.6.1.4.1.20044.54.6.1.260.1Scalarrm10010mpCtrlResetrmonread-writecurrentModule Rmon Global Reset :This OID resets all the Rmon counters on the module <Help > This control initiates a reset of the Rmon counters on the module
1.3.6.1.4.1.20044.54.6.1.261Noderm10010mpCtrlresetMeasurements
1.3.6.1.4.1.20044.54.6.1.261.1Scalarrm10010mpCtrlResetmeasurementsread-writecurrentManagement Meas Global Reset :This OID resets some measurements on the management <Help > This control initiates a reset of some measurements on the management
1.3.6.1.4.1.20044.54.6.2Noderm10010mpCtrlClient
1.3.6.1.4.1.20044.54.6.2.16Tablerm10010mpCtrlaccessLoopTablenot-accessiblecurrentList of rm10010mpCtrlaccessLoop Article
1.3.6.1.4.1.20044.54.6.2.16.1Rowrm10010mpCtrlaccessLoopEntrynot-accessiblecurrentRow definition for the rm10010mpCtrlaccessLoop table
1.3.6.1.4.1.20044.54.6.2.16.1.1Columnrm10010mpCtrlaccessLoopIndexread-onlycurrentIndex definition for the rm10010mpCtrlaccessLoop table
1.3.6.1.4.1.20044.54.6.2.16.1.2Columnrm10010mpCtrlaccessLoopPortnread-writecurrentClient Facility Loopback :This OID, when set at '1' puts the client port in loopback, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. <Help…
1.3.6.1.4.1.20044.54.6.2.17Tablerm10010mpCtrlclientLoopToLineTablenot-accessiblecurrentList of rm10010mpCtrlclientLoopToLine Article
1.3.6.1.4.1.20044.54.6.2.17.1Rowrm10010mpCtrlclientLoopToLineEntrynot-accessiblecurrentRow definition for the rm10010mpCtrlclientLoopToLine table
1.3.6.1.4.1.20044.54.6.2.17.1.1Columnrm10010mpCtrlclientLoopToLineIndexread-onlycurrentIndex definition for the rm10010mpCtrlclientLoopToLine table
1.3.6.1.4.1.20044.54.6.2.17.1.2Columnrm10010mpCtrlclientLoopToLinePortnread-writecurrentClient Terminal Loopback :This OID, when set, puts the client port in loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.<Help> This control ena…
1.3.6.1.4.1.20044.54.6.2.21Tablerm10010mpCtrlcsfUpInsTablenot-accessiblecurrentList of rm10010mpCtrlcsfUpIns Article
1.3.6.1.4.1.20044.54.6.2.21.1Rowrm10010mpCtrlcsfUpInsEntrynot-accessiblecurrentRow definition for the rm10010mpCtrlcsfUpIns table
1.3.6.1.4.1.20044.54.6.2.21.1.1Columnrm10010mpCtrlcsfUpInsIndexread-onlycurrentIndex definition for the rm10010mpCtrlcsfUpIns table
1.3.6.1.4.1.20044.54.6.2.21.1.2Columnrm10010mpCtrlcsfUpInsPortnread-writecurrentClient Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo…
1.3.6.1.4.1.20044.54.6.2.22Tablerm10010mpCtrlcaisDwInsTablenot-accessiblecurrentList of rm10010mpCtrlcaisDwIns Article
1.3.6.1.4.1.20044.54.6.2.22.1Rowrm10010mpCtrlcaisDwInsEntrynot-accessiblecurrentRow definition for the rm10010mpCtrlcaisDwIns table
1.3.6.1.4.1.20044.54.6.2.22.1.1Columnrm10010mpCtrlcaisDwInsIndexread-onlycurrentIndex definition for the rm10010mpCtrlcaisDwIns table
1.3.6.1.4.1.20044.54.6.2.22.1.2Columnrm10010mpCtrlcaisDwInsPortnread-writecurrentClient AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port
1.3.6.1.4.1.20044.54.6.3Noderm10010mpCtrlLine
1.3.6.1.4.1.20044.54.6.3.64Tablerm10010mpCtrlcommAccessLoopTablenot-accessiblecurrentList of rm10010mpCtrlcommAccessLoop Article
1.3.6.1.4.1.20044.54.6.3.64.1Rowrm10010mpCtrlcommAccessLoopEntrynot-accessiblecurrentRow definition for the rm10010mpCtrlcommAccessLoop table
1.3.6.1.4.1.20044.54.6.3.64.1.1Columnrm10010mpCtrlcommAccessLoopIndexread-onlycurrentIndex definition for the rm10010mpCtrlcommAccessLoop table
1.3.6.1.4.1.20044.54.6.3.64.1.2Columnrm10010mpCtrlcommAccessLoopPortnread-writecurrentLine Terminal Loopback :This OID, when set, puts the module in common access loop back, looping the 100 Gb/s output signal on the 100 Gb/s input.<Help> This co…
1.3.6.1.4.1.20044.54.6.3.66Tablerm10010mpCtrllineLoopTablenot-accessiblecurrentList of rm10010mpCtrllineLoop Article
1.3.6.1.4.1.20044.54.6.3.66.1Rowrm10010mpCtrllineLoopEntrynot-accessiblecurrentRow definition for the rm10010mpCtrllineLoop table
1.3.6.1.4.1.20044.54.6.3.66.1.1Columnrm10010mpCtrllineLoopIndexread-onlycurrentIndex definition for the rm10010mpCtrllineLoop table
1.3.6.1.4.1.20044.54.6.3.66.1.2Columnrm10010mpCtrllineLoopPortnread-writecurrentLine Facility Loopback :This OID, when set at '1' puts the module in line loopback mode, looping the received 100 Gb/s signal on the transmit 100 Gb/s output. …
1.3.6.1.4.1.20044.54.6.3.69Tablerm10010mpCtrlfecDisableTablenot-accessiblecurrentList of rm10010mpCtrlfecDisable Article
1.3.6.1.4.1.20044.54.6.3.69.1Rowrm10010mpCtrlfecDisableEntrynot-accessiblecurrentRow definition for the rm10010mpCtrlfecDisable table
1.3.6.1.4.1.20044.54.6.3.69.1.1Columnrm10010mpCtrlfecDisableIndexread-onlycurrentIndex definition for the rm10010mpCtrlfecDisable table
1.3.6.1.4.1.20044.54.6.3.69.1.2Columnrm10010mpCtrlfecDisablePortnread-writecurrentForward Error Correction Inhibition :This OID, when set, inhibits the Forward Error Correction feature on the line input <Help> This control enables/disables t…
1.3.6.1.4.1.20044.54.6.3.209Tablerm10010mpCtrlmsaLineLoopTablenot-accessiblecurrentList of rm10010mpCtrlmsaLineLoop Article
1.3.6.1.4.1.20044.54.6.3.209.1Rowrm10010mpCtrlmsaLineLoopEntrynot-accessiblecurrentRow definition for the rm10010mpCtrlmsaLineLoop table
1.3.6.1.4.1.20044.54.6.3.209.1.1Columnrm10010mpCtrlmsaLineLoopIndexread-onlycurrentIndex definition for the rm10010mpCtrlmsaLineLoop table
1.3.6.1.4.1.20044.54.6.3.209.1.2Columnrm10010mpCtrlmsaLineLoopPortnread-writecurrentMSA Line Loop :This OID operates a line loopback on the MSA Line <Help> This control defines the line loop back of the line transceiver
1.3.6.1.4.1.20044.54.6.3.210Tablerm10010mpCtrlmsaTxResetTablenot-accessiblecurrentList of rm10010mpCtrlmsaTxReset Article
1.3.6.1.4.1.20044.54.6.3.210.1Rowrm10010mpCtrlmsaTxResetEntrynot-accessiblecurrentRow definition for the rm10010mpCtrlmsaTxReset table
1.3.6.1.4.1.20044.54.6.3.210.1.1Columnrm10010mpCtrlmsaTxResetIndexread-onlycurrentIndex definition for the rm10010mpCtrlmsaTxReset table
1.3.6.1.4.1.20044.54.6.3.210.1.2Columnrm10010mpCtrlmsaTxResetPortnread-writecurrentLine MSA TX Reset :This OID resets the TX portion of the MSA line module <Help > This control initiates a reset of the transmitting side
1.3.6.1.4.1.20044.54.6.3.211Tablerm10010mpCtrlmsaRxResetTablenot-accessiblecurrentList of rm10010mpCtrlmsaRxReset Article
1.3.6.1.4.1.20044.54.6.3.211.1Rowrm10010mpCtrlmsaRxResetEntrynot-accessiblecurrentRow definition for the rm10010mpCtrlmsaRxReset table
1.3.6.1.4.1.20044.54.6.3.211.1.1Columnrm10010mpCtrlmsaRxResetIndexread-onlycurrentIndex definition for the rm10010mpCtrlmsaRxReset table
1.3.6.1.4.1.20044.54.6.3.211.1.2Columnrm10010mpCtrlmsaRxResetPortnread-writecurrentLine MSA RX Reset :This OID resets the RX portion of the MSA line module <Help > This control initiates a reset of the receiving side
1.3.6.1.4.1.20044.54.6.3.212Tablerm10010mpCtrlmsaShutdownTablenot-accessiblecurrentList of rm10010mpCtrlmsaShutdown Article
1.3.6.1.4.1.20044.54.6.3.212.1Rowrm10010mpCtrlmsaShutdownEntrynot-accessiblecurrentRow definition for the rm10010mpCtrlmsaShutdown table
1.3.6.1.4.1.20044.54.6.3.212.1.1Columnrm10010mpCtrlmsaShutdownIndexread-onlycurrentIndex definition for the rm10010mpCtrlmsaShutdown table
1.3.6.1.4.1.20044.54.6.3.212.1.2Columnrm10010mpCtrlmsaShutdownPortnread-writecurrentLine MSA Shutdown :This OID enters a process to shutdown the MSA line module <Help > This control initiates a shutdown of the module
1.3.6.1.4.1.20044.54.7Noderm10010mpri
1.3.6.1.4.1.20044.54.7.1Noderm10010mpriTable
1.3.6.1.4.1.20044.54.7.1.1Tablerm10010mpRinvSfpTablenot-accessiblecurrentList of the SFPs on the selected module
1.3.6.1.4.1.20044.54.7.1.1.1Rowrm10010mpRinvSfpEntrynot-accessiblecurrentRow definition for the SFP table
1.3.6.1.4.1.20044.54.7.1.1.1.1Columnrm10010mpRinvSfpIndexread-onlycurrentIndex for SFP table
1.3.6.1.4.1.20044.54.7.1.1.1.2Columnrm10010mpRinvsfpread-onlycurrentInventory for the SFP: This OID contains the inventory for the SFP
1.3.6.1.4.1.20044.54.7.1.2Tablerm10010mpRinvLineTablenot-accessiblecurrentList of the XFPs on the selected module
1.3.6.1.4.1.20044.54.7.1.2.1Rowrm10010mpRinvLineEntrynot-accessiblecurrentRow definition for the XFP table
1.3.6.1.4.1.20044.54.7.1.2.1.1Columnrm10010mpRinvLineIndexread-onlycurrentIndex for XFP table
1.3.6.1.4.1.20044.54.7.1.2.1.2Columnrm10010mpRinvxfpLineread-onlycurrentInventory for the XFP: This OID contains the inventory for the XFP
1.3.6.1.4.1.20044.54.7.2Scalarrm10010mpRinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.54.7.3Scalarrm10010mpRinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.54.7.4Scalarrm10010mpRinvModulePlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.54.7.5Scalarrm10010mpRinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.54.7.6Scalarrm10010mpRinvGwPlatformread-onlycurrentGW platform desciption: This OID contains the description of the Gateware platform.
1.3.6.1.4.1.20044.54.8Noderm10010mpdownload
1.3.6.1.4.1.20044.54.8.1Noderm10010mpDwlOther
1.3.6.1.4.1.20044.54.8.1.0Noderm10010mpDwlrestartProcess
1.3.6.1.4.1.20044.54.8.1.0.1Scalarrm10010mpDwlWarmRestartProcessedread-onlycurrentWarm Restart :This OID indicates that the module last restart was a Warm RESTART
1.3.6.1.4.1.20044.54.8.1.0.2Scalarrm10010mpDwlColdRestartProcessedread-onlycurrentCold Restart :This OID indicates that the module last restart was a Cold RESTART
1.3.6.1.4.1.20044.54.8.1.1Noderm10010mpDwlswBanksUsed
1.3.6.1.4.1.20044.54.8.1.1.1Scalarrm10010mpDwlSwBank1Usedread-onlycurrentSW bank 1 active :This OID indicates the module is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby
1.3.6.1.4.1.20044.54.8.1.1.2Scalarrm10010mpDwlSwBank2Usedread-onlycurrentSW bank 2 active :This OID indicates the module is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby
1.3.6.1.4.1.20044.54.8.1.1.5Scalarrm10010mpDwlSwBank1Notemptyread-onlycurrentSW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 <Help> This status indicates if the SW bank 1 contains SW package
1.3.6.1.4.1.20044.54.8.1.1.6Scalarrm10010mpDwlSwBank2Notemptyread-onlycurrentSW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 <Help> This status indicates if the SW bank 2 contains SW package
1.3.6.1.4.1.20044.54.8.1.2Noderm10010mpDwlgwBanksUsed
1.3.6.1.4.1.20044.54.8.1.2.1Scalarrm10010mpDwlGwBank1Usedread-onlycurrentGW bank 1 active :This OID indicates the module is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby
1.3.6.1.4.1.20044.54.8.1.2.2Scalarrm10010mpDwlGwBank2Usedread-onlycurrentGW bank 2 active :This OID indicates the module is working on GW bank 2
1.3.6.1.4.1.20044.54.8.1.2.3Scalarrm10010mpDwlGwBank3Usedread-onlycurrentGW bank 3 active :This OID indicates the module is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby
1.3.6.1.4.1.20044.54.8.1.2.4Scalarrm10010mpDwlGwBank4Usedread-onlycurrentGW bank 4 active :This OID indicates the module is working on GW bank 4
1.3.6.1.4.1.20044.54.8.1.2.5Scalarrm10010mpDwlGwBank1Notemptyread-onlycurrentGW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 <Help> This status indicates if the GW bank 1 contains GW package
1.3.6.1.4.1.20044.54.8.1.2.6Scalarrm10010mpDwlGwBank2Notemptyread-onlycurrentGW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2
1.3.6.1.4.1.20044.54.8.1.2.7Scalarrm10010mpDwlGwBank3Notemptyread-onlycurrentGW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 <Help> This status indicates if the GW bank 3 contains GW package
1.3.6.1.4.1.20044.54.8.1.2.8Scalarrm10010mpDwlGwBank4Notemptyread-onlycurrentGW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4
1.3.6.1.4.1.20044.54.8.2Noderm10010mpDwlClient
1.3.6.1.4.1.20044.54.8.3Noderm10010mpDwlLine
1.3.6.1.4.1.20044.54.9Noderm10010mpConfig
1.3.6.1.4.1.20044.54.9.1Noderm10010mpCfgAccessCAisCsf
1.3.6.1.4.1.20044.54.9.1.1Tablerm10010mpCfgClientcaiscsfTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.54.9.1.1.1Rowrm10010mpCfgClientcaiscsfEntrynot-accessiblecurrentRow definition for the accessCAisCsf table
1.3.6.1.4.1.20044.54.9.1.1.1.1Columnrm10010mpCfgClientcaiscsfIndexread-onlycurrentIndex definition for the clientcaiscsf table
1.3.6.1.4.1.20044.54.9.1.1.1.3Columnrm10010mpCfgReservePortnread-writecurrentCAIS mode on Client Port :This register enables/disables port laser shutdown on CAIS insertion condition
1.3.6.1.4.1.20044.54.9.2Noderm10010mpCfgStartup
1.3.6.1.4.1.20044.54.9.2.1Tablerm10010mpCfgClientStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.54.9.2.1.1Rowrm10010mpCfgClientStartupEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.54.9.2.1.1.1Columnrm10010mpCfgClientStartupIndexread-onlycurrentIndex definition for the clientStartup table
1.3.6.1.4.1.20044.54.9.2.1.1.3Columnrm10010mpCfgSystConfPortPortnread-writecurrentDefault Settings on Client Port :This register configures the default initialisation settings on the port.
1.3.6.1.4.1.20044.54.9.2.1.1.4Columnrm10010mpCfgNetConfPortPortnread-writecurrentDefault Settings on Client Port :This register configures the default initialisation settings on the port.
1.3.6.1.4.1.20044.54.9.2.1.1.14Columnrm10010mpCfgOptionsPortPortnread-writecurrentDefault Options on Client Port :This register configures the default options on the port.
1.3.6.1.4.1.20044.54.9.2.2Tablerm10010mpCfgLineStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.54.9.2.2.1Rowrm10010mpCfgLineStartupEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.54.9.2.2.1.1Columnrm10010mpCfgLineStartupIndexread-onlycurrentIndex definition for the lineStartup table
1.3.6.1.4.1.20044.54.9.2.2.1.3Columnrm10010mpCfgSystConfLinePortnread-writecurrentDefault Settings on Line :This register configures the default initialisation settings on Line
1.3.6.1.4.1.20044.54.9.2.2.1.14Columnrm10010mpCfgOptionsLinePortnread-writecurrentDefault Options on Line :This register configures the default options on the line
1.3.6.1.4.1.20044.54.9.2.3Tablerm10010mpCfgXfpTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.54.9.2.3.1Rowrm10010mpCfgXfpEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.54.9.2.3.1.1Columnrm10010mpCfgXfpIndexread-onlycurrentIndex definition for the xfp table
1.3.6.1.4.1.20044.54.9.2.3.1.3Columnrm10010mpCfgSystConfMsaLinePortnread-writecurrentDefault settings on MSA :This register configures the default initialisation settings on MSA
1.3.6.1.4.1.20044.54.9.3Noderm10010mpCfgLabels
1.3.6.1.4.1.20044.54.9.3.1Tablerm10010mpCfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.54.9.3.1.1Rowrm10010mpCfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.54.9.3.1.1.1Columnrm10010mpCfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.54.9.3.1.1.3Columnrm10010mpCfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.54.9.3.2Tablerm10010mpCfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.54.9.3.2.1Rowrm10010mpCfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.54.9.3.2.1.1Columnrm10010mpCfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.54.9.3.2.1.3Columnrm10010mpCfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.54.9.4Noderm10010mpCfgStartuptlh
1.3.6.1.4.1.20044.54.9.4.1Tablerm10010mpCfgOtxtlhTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.54.9.4.1.1Rowrm10010mpCfgOtxtlhEntrynot-accessiblecurrentRow definition for the startuptlh table
1.3.6.1.4.1.20044.54.9.4.1.1.1Columnrm10010mpCfgOtxtlhIndexread-onlycurrentIndex definition for the otxtlh table
1.3.6.1.4.1.20044.54.9.4.1.1.6Columnrm10010mpCfgLinePwrLaserPortnread-writecurrentDefaut Line output Power :This register configures the start-up output power of the Line tranceiver (Unit = dBm)
1.3.6.1.4.1.20044.54.9.4.1.1.7Columnrm10010mpCfgLineFCurrentPortnread-writecurrentDefault Line transceiver Tx Channel :This register configures the start-up laser channel of the Line Tx transceiver
1.3.6.1.4.1.20044.54.9.4.1.1.8Columnrm10010mpCfgLineGridCurrentPortnread-writecurrentDefault Line transceiver Grid :This register configures the start-up laser grid of the Line transceiver
1.3.6.1.4.1.20044.54.9.4.1.1.9Columnrm10010mpCfgFPortnread-writecurrentDefault Line TRX lowest Freq :This register configures the start-up lowest frequency of the Line transceiver
1.3.6.1.4.1.20044.54.9.4.1.1.10Columnrm10010mpCfgRxLineFCurrentPortnread-writecurrentDefault Line transceiver Rx Channel :This register configures the start-up laser channel of the Line Rx transceiver
1.3.6.1.4.1.20044.54.9.5Noderm10010mpCfgOther
1.3.6.1.4.1.20044.54.9.5.1Noderm10010mptablemoduleOther
1.3.6.1.4.1.20044.54.9.5.1.2Scalarrm10010mpCfgmoderead-writecurrentDefault settings on Module :This register selects the configuration mode of the module
1.3.6.1.4.1.20044.54.9.5.1.3Scalarrm10010mpCfgfanLowSpeedThresholdread-writecurrentDefault settings on Module :This register selects the speed threshold of the fan's
1.3.6.1.4.1.20044.54.9.5.1.4Scalarrm10010mpCfgfanHighSpeedThresholdread-writecurrentDefault settings on Module :This register selects the speed threshold of the fan's
1.3.6.1.4.1.20044.54.9.6Noderm10010mpCfgStartuptablefive
1.3.6.1.4.1.20044.54.9.6.1Tablerm10010mpCfgOtxtlhcapabilitiesTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.54.9.6.1.1Rowrm10010mpCfgOtxtlhcapabilitiesEntrynot-accessiblecurrentRow definition for the startuptablefive table
1.3.6.1.4.1.20044.54.9.6.1.1.1Columnrm10010mpCfgOtxtlhcapabilitiesIndexread-onlycurrentIndex definition for the otxtlhcapabilities table
1.3.6.1.4.1.20044.54.9.6.1.1.3Columnrm10010mpCfgComponentTypePortnread-onlycurrentComponent parameters :This OID defines the component parameters
1.3.6.1.4.1.20044.54.9.6.1.1.4Columnrm10010mpCfgMiscellaneousPortnread-onlycurrentMiscellaneous default settings :This OID defines the miscellaneous parameters
1.3.6.1.4.1.20044.54.9.6.1.1.5Columnrm10010mpCfgFirstChannelPortnread-onlycurrentNumber of the first channel of the component :This OID defines the first channel number of the PM
1.3.6.1.4.1.20044.54.9.6.1.1.6Columnrm10010mpCfgLastChannelPortnread-onlycurrentNumber of the last channel of the component :This OID defines the last channel number of the PM
1.3.6.1.4.1.20044.54.9.6.1.1.7Columnrm10010mpCfgGridPortnread-onlycurrentGrid value of the component :This OID defines the grid of the PM
1.3.6.1.4.1.20044.54.9.257Scalarrm10010mpCfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.54.10Noderm10010mptraps
1.3.6.1.4.1.20044.54.10.2Scalarrm10010mptrapPortNumberread-onlycurrentLast port which generates a trap
1.3.6.1.4.1.20044.54.10.3Scalarrm10010mptrapLineNumberread-onlycurrentLast Line which generates a trap
1.3.6.1.4.1.20044.54.10.4Scalarrm10010mptrapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.54.10.30Notificationrm10010mpLineTrapNotUrgentGoesOncurrentNot urgent Line default is activated
1.3.6.1.4.1.20044.54.10.31Notificationrm10010mpLineTrapNotUrgentGoesOffcurrentNot urgent Line default disappeared
1.3.6.1.4.1.20044.54.10.32Notificationrm10010mpLineTrapUrgentGoesOncurrentUrgent Line default is activated
1.3.6.1.4.1.20044.54.10.33Notificationrm10010mpLineTrapUrgentGoesOffcurrentUrgent Line default disappeared
1.3.6.1.4.1.20044.54.10.34Notificationrm10010mpLineTrapCritGoesOncurrentCritical Line default is activated
1.3.6.1.4.1.20044.54.10.35Notificationrm10010mpLineTrapCritGoesOffcurrentCritical Line default disappeared
1.3.6.1.4.1.20044.54.10.40Notificationrm10010mpClientTrapNotUrgentGoesOncurrentNot urgent client default is activated
1.3.6.1.4.1.20044.54.10.41Notificationrm10010mpClientTrapNotUrgentGoesOffcurrentNot urgent client default disappeared
1.3.6.1.4.1.20044.54.10.42Notificationrm10010mpClientTrapUrgentGoesOncurrentUrgent client default is activated
1.3.6.1.4.1.20044.54.10.43Notificationrm10010mpClientTrapUrgentGoesOffcurrentUrgent client default disappeared
1.3.6.1.4.1.20044.54.10.44Notificationrm10010mpClientTrapCritGoesOncurrentCritical client default is activated
1.3.6.1.4.1.20044.54.10.45Notificationrm10010mpClientTrapCritGoesOffcurrentCritical client default disappeared
1.3.6.1.4.1.20044.54.10.50Notificationrm10010mpPowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.54.10.51Notificationrm10010mpPowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared
1.3.6.1.4.1.20044.54.11Noderm10010mpMonitoring
1.3.6.1.4.1.20044.54.11.1Noderm10010mpMonOther
1.3.6.1.4.1.20044.54.11.1.3Noderm10010mpMonRmon
1.3.6.1.4.1.20044.54.11.2Noderm10010mpMonClient
1.3.6.1.4.1.20044.54.11.2.4Noderm10010mpMonClientRmonCounter
1.3.6.1.4.1.20044.54.11.2.4.16Tablerm10010mpMonupRmonBytesCounterClientInputTablenot-accessiblecurrentList of rm10010mpMonupRmonBytesCounterClientInput Article
1.3.6.1.4.1.20044.54.11.2.4.16.1Rowrm10010mpMonupRmonBytesCounterClientInputEntrynot-accessiblecurrentRow definition for the rm10010mpMonupRmonBytesCounterClientInput table
1.3.6.1.4.1.20044.54.11.2.4.16.1.1Columnrm10010mpMonupRmonBytesCounterClientInputIndexread-onlycurrentIndex definition for the rm10010mpMonupRmonBytesCounterClientInput table
1.3.6.1.4.1.20044.54.11.2.4.16.1.2Columnrm10010mpMonupRmonBytesCounterClientInputValuePortnread-onlycurrentClient Input Bytes :This counter is increased each time a data byte is received on the client port <Help> This counter gives the number of bytes received on th…
1.3.6.1.4.1.20044.54.11.2.4.16.1.3Columnrm10010mpMonupRmonBytesCounterClientInputErrorPortnread-onlycurrentBytes Counter Error :This OID when set indicates the Bytes counter value is invalid on client port
1.3.6.1.4.1.20044.54.11.2.4.16.1.4Columnrm10010mpMonupRmonBytesCounterClientInputOverloadPortnread-onlycurrentBytes Counter Overload :This OID when set indicates a Bytes counter overload on client port
1.3.6.1.4.1.20044.54.11.2.4.32Tablerm10010mpMonupRmonCrcErrorsCounterClientInputTablenot-accessiblecurrentList of rm10010mpMonupRmonCrcErrorsCounterClientInput Article
1.3.6.1.4.1.20044.54.11.2.4.32.1Rowrm10010mpMonupRmonCrcErrorsCounterClientInputEntrynot-accessiblecurrentRow definition for the rm10010mpMonupRmonCrcErrorsCounterClientInput table
1.3.6.1.4.1.20044.54.11.2.4.32.1.1Columnrm10010mpMonupRmonCrcErrorsCounterClientInputIndexread-onlycurrentIndex definition for the rm10010mpMonupRmonCrcErrorsCounterClientInput table
1.3.6.1.4.1.20044.54.11.2.4.32.1.2Columnrm10010mpMonupRmonCrcErrorsCounterClientInputValuePortnread-onlycurrentClient Input CRC Errors :This counter is increased each time a B1/CRC error is detected on the client port <Help> This counter gives the number of B1/CRC Error…
1.3.6.1.4.1.20044.54.11.2.4.32.1.3Columnrm10010mpMonupRmonCrcErrorsCounterClientInputErrorPortnread-onlycurrentCRC Errors Counter Error :This OID when set indicates the CRC Errors counter value is invalid on client port
1.3.6.1.4.1.20044.54.11.2.4.32.1.4Columnrm10010mpMonupRmonCrcErrorsCounterClientInputOverloadPortnread-onlycurrentCRC Errors Counter Overload :This OID when set indicates a CRC Errors counter overload on client port
1.3.6.1.4.1.20044.54.11.2.4.48Tablerm10010mpMonupRmonPacketsCounterClientInputTablenot-accessiblecurrentList of rm10010mpMonupRmonPacketsCounterClientInput Article
1.3.6.1.4.1.20044.54.11.2.4.48.1Rowrm10010mpMonupRmonPacketsCounterClientInputEntrynot-accessiblecurrentRow definition for the rm10010mpMonupRmonPacketsCounterClientInput table
1.3.6.1.4.1.20044.54.11.2.4.48.1.1Columnrm10010mpMonupRmonPacketsCounterClientInputIndexread-onlycurrentIndex definition for the rm10010mpMonupRmonPacketsCounterClientInput table
1.3.6.1.4.1.20044.54.11.2.4.48.1.2Columnrm10010mpMonupRmonPacketsCounterClientInputValuePortnread-onlycurrentClient Input Packets :This counter is increased each time a packet is received on the client port <Help> This counter gives the number of packets received on t…
1.3.6.1.4.1.20044.54.11.2.4.48.1.3Columnrm10010mpMonupRmonPacketsCounterClientInputErrorPortnread-onlycurrentPackets Counter Error :This OID when set indicates the Packets counter value is invalid on client port
1.3.6.1.4.1.20044.54.11.2.4.48.1.4Columnrm10010mpMonupRmonPacketsCounterClientInputOverloadPortnread-onlycurrentPackets Counter Overload :This OID when set indicates a Packets counter overload on client port
1.3.6.1.4.1.20044.54.11.2.4.64Tablerm10010mpMonupRmonBroadcastCounterClientInputTablenot-accessiblecurrentList of rm10010mpMonupRmonBroadcastCounterClientInput Article
1.3.6.1.4.1.20044.54.11.2.4.64.1Rowrm10010mpMonupRmonBroadcastCounterClientInputEntrynot-accessiblecurrentRow definition for the rm10010mpMonupRmonBroadcastCounterClientInput table
1.3.6.1.4.1.20044.54.11.2.4.64.1.1Columnrm10010mpMonupRmonBroadcastCounterClientInputIndexread-onlycurrentIndex definition for the rm10010mpMonupRmonBroadcastCounterClientInput table
1.3.6.1.4.1.20044.54.11.2.4.64.1.2Columnrm10010mpMonupRmonBroadcastCounterClientInputValuePortnread-onlycurrentClient Input Broadcast Packets :This counter is increased each time a broadcast packet is received on the client port <Help> This counter gives the number of B…
1.3.6.1.4.1.20044.54.11.2.4.64.1.3Columnrm10010mpMonupRmonBroadcastCounterClientInputErrorPortnread-onlycurrentBroadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on client port
1.3.6.1.4.1.20044.54.11.2.4.64.1.4Columnrm10010mpMonupRmonBroadcastCounterClientInputOverloadPortnread-onlycurrentBroadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port
1.3.6.1.4.1.20044.54.11.2.4.80Tablerm10010mpMonupRmonMulticastCounterClientInputTablenot-accessiblecurrentList of rm10010mpMonupRmonMulticastCounterClientInput Article
1.3.6.1.4.1.20044.54.11.2.4.80.1Rowrm10010mpMonupRmonMulticastCounterClientInputEntrynot-accessiblecurrentRow definition for the rm10010mpMonupRmonMulticastCounterClientInput table
1.3.6.1.4.1.20044.54.11.2.4.80.1.1Columnrm10010mpMonupRmonMulticastCounterClientInputIndexread-onlycurrentIndex definition for the rm10010mpMonupRmonMulticastCounterClientInput table
1.3.6.1.4.1.20044.54.11.2.4.80.1.2Columnrm10010mpMonupRmonMulticastCounterClientInputValuePortnread-onlycurrentClient Input Multicast Packets :This counter is increased each time a Multicast packet is received on the client port <Help> This counter gives the number of M…
1.3.6.1.4.1.20044.54.11.2.4.80.1.3Columnrm10010mpMonupRmonMulticastCounterClientInputErrorPortnread-onlycurrentMulticast Counter Error :This OID when set indicates the Multicast counter value is invalid on client port
1.3.6.1.4.1.20044.54.11.2.4.80.1.4Columnrm10010mpMonupRmonMulticastCounterClientInputOverloadPortnread-onlycurrentMulticast Counter Overload :This OID when set indicates a Multicast counter overload on client port
1.3.6.1.4.1.20044.54.11.2.4.96Tablerm10010mpMonupRmonPauseFrameCounterClientInputTablenot-accessiblecurrentList of rm10010mpMonupRmonPauseFrameCounterClientInput Article
1.3.6.1.4.1.20044.54.11.2.4.96.1Rowrm10010mpMonupRmonPauseFrameCounterClientInputEntrynot-accessiblecurrentRow definition for the rm10010mpMonupRmonPauseFrameCounterClientInput table
1.3.6.1.4.1.20044.54.11.2.4.96.1.1Columnrm10010mpMonupRmonPauseFrameCounterClientInputIndexread-onlycurrentIndex definition for the rm10010mpMonupRmonPauseFrameCounterClientInput table
1.3.6.1.4.1.20044.54.11.2.4.96.1.2Columnrm10010mpMonupRmonPauseFrameCounterClientInputValuePortnread-onlycurrentClient Input Pause Frames :This counter is increased each time a Pause frame is received on the client port <Help> This counter gives the number of Pause frame…
1.3.6.1.4.1.20044.54.11.2.4.96.1.3Columnrm10010mpMonupRmonPauseFrameCounterClientInputErrorPortnread-onlycurrentPause Counter Error :This OID when set indicates the Pause counter value is invalid on client port
1.3.6.1.4.1.20044.54.11.2.4.96.1.4Columnrm10010mpMonupRmonPauseFrameCounterClientInputOverloadPortnread-onlycurrentPause Counter Overload :This OID when set indicates a Pause counter overload on client port
Type Definitions
NameSyntaxStatusDescription
Rm10010mpAdjustValueINTEGER { otxadjustvalue0(0), otxadjustvalue1(1), otxadjustvalue2(2), otxadjustvalue3(3), otxadjustvalue4(4), otxadjustvalue5(5), otxadjustvalue6(6), otxadjustvalue7(7), otxadjustvalue8(8), otxadjustvalue9(9), otxadjustvalue10(10) }currentDifferent values in Adjust mode on OTX-TLH on client and line ports
Rm10010mpClientProtocolINTEGER { protocolclientvalue0(0), protocolclientvalue1(1), protocolclientvalue2(2), protocolclientvalue3(3), protocolclientvalue4(4), protocolclientvalue5(5), protocolclientvalue6(6), protocolclientvalue7(7), protocolclientvalue8(8) }currentDifferent values on the protocol on the client ports
Rm10010mpMultiRateINTEGER { rate100Mhz(0), rate250Mhz(1), rate500Mhz(2), rate1Ghz(3) }currentdifferent rate for a client port
Rm10010mpOrxChannelINTEGERcurrentChannel selection on transceiver Rx line ports
Rm10010mpOtxChannelINTEGERcurrentChannel selection on transceiver Tx line ports
Rm10010mpOtxGridINTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50) }currentDifferent grids on OTX-TLH on client and line ports
Rm10010mpOtxModeINTEGER { otx80mode(1), otx60mode(2), otxadjustmode(4) }currentDifferent modes on OTX-TLH on client and line ports
Rm10010mpProtocolModeINTEGER { protocolmodevalue0(0), protocolmodevalue1(1), protocolmodevalue2(2), protocolmodevalue3(3) }currentDifferent values on the protocol mode