EKINOPS-Rmoac17wb-MIB

317 objects
Creation
OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.102Identitymodulermoac17wbCreation
1.3.6.1.4.1.20044.102.2Nodermoac17wbalarms
1.3.6.1.4.1.20044.102.2.1Nodermoac17wbAlmOther
1.3.6.1.4.1.20044.102.2.1.1Nodermoac17wbAlmOtherNurg
1.3.6.1.4.1.20044.102.2.1.1.2Nodermoac17wbAlmsynthAlm2
1.3.6.1.4.1.20044.102.2.1.1.2.1Scalarrmoac17wbAlmConfTableSaveread-onlycurrentPM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> other…
1.3.6.1.4.1.20044.102.2.1.1.2.2Scalarrmoac17wbAlmInvUploadread-onlycurrentInventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> other (1) <Alarmtype> other (1) <Polarit…
1.3.6.1.4.1.20044.102.2.1.1.2.3Scalarrmoac17wbAlmConfTableLoadread-onlycurrentPM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> other (1) <Alarmt…
1.3.6.1.4.1.20044.102.2.1.1.75Nodermoac17wbAlmfoaWarnings
1.3.6.1.4.1.20044.102.2.1.1.75.7Scalarrmoac17wbAlmTermpLowWarningread-onlycurrentTemperature Low Warning :This OID indicates that the PM temperature if lower than the Warning threshold <Condtype> TERMP_LOW_WARNING <Probcause> temperatureUna…
1.3.6.1.4.1.20044.102.2.1.1.75.8Scalarrmoac17wbAlmTempHighWarningread-onlycurrentTemperature High Warning :This OID indicates that the PM temperature if higher than the Warning threshold <Condtype> TEMP_HIGH_WARNING <Probcause> temperatureU…
1.3.6.1.4.1.20044.102.2.1.2Nodermoac17wbAlmOtherUrg
1.3.6.1.4.1.20044.102.2.1.2.74Nodermoac17wbAlmfoaAlarms
1.3.6.1.4.1.20044.102.2.1.2.74.7Scalarrmoac17wbAlmTermpLowAlarmread-onlycurrentTemperature Low Alarm :This OID indicates that the PM temperature if lower than the alarm threshold <Condtype> TERMP_LOW_ALARM <Probcause> temperatureUnaccepta…
1.3.6.1.4.1.20044.102.2.1.2.74.8Scalarrmoac17wbAlmTempHighAlarmread-onlycurrentTemperature High Alarm :This OID indicates that the PM temperature is higher than the alarm threshold <Condtype> TEMP_HIGH_ALARM <Probcause> temperatureUnaccep…
1.3.6.1.4.1.20044.102.2.1.3Nodermoac17wbAlmOtherCrit
1.3.6.1.4.1.20044.102.2.1.3.0Nodermoac17wbAlmsynthAlm0
1.3.6.1.4.1.20044.102.2.1.3.0.1Scalarrmoac17wbAlmMaintenanceModeread-onlycurrentMaintenance Mode :This OID indicates that the PM is in maintenance mode <Help> This status indiates if the module is currently in maintenance mode <Condtype> M…
1.3.6.1.4.1.20044.102.2.1.3.0.2Scalarrmoac17wbAlmAprOnread-onlycurrentAutomatic Power Reduction :This OID indicates that the APR algorithm has been operated and the output of the lasers are shutdown <Help> The APR algorithm has b…
1.3.6.1.4.1.20044.102.2.1.3.0.9Scalarrmoac17wbAlmModGlobFailread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the PM <Condtype> MOD_GLOB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> sy…
1.3.6.1.4.1.20044.102.2.1.3.0.10Scalarrmoac17wbAlmUpEdfaInitNotComplread-onlycurrentIL1 Not Initialized :This OID indicates that the initialisation of the IL1 is not completed <Help> This status indicates if the IL1 has been correctly initiali…
1.3.6.1.4.1.20044.102.2.1.3.0.11Scalarrmoac17wbAlmDwEdfaInitNotComplread-onlycurrentIL2 Not Initialized :This OID indicates that the initialisation of the IL2 is not completed <Help> This status indicates if the IL2 has been correctly initiali…
1.3.6.1.4.1.20044.102.2.1.3.0.12Scalarrmoac17wbAlmExtPump1NotLockedread-onlycurrentExternal Pump Not Detected :This OID indicates that the first external pump is not detected by the amplifier module <Help> This alarm indicates if the external…
1.3.6.1.4.1.20044.102.2.1.3.0.15Scalarrmoac17wbAlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.102.2.1.3.0.16Scalarrmoac17wbAlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.102.2.2Nodermoac17wbAlmClient
1.3.6.1.4.1.20044.102.2.2.1Nodermoac17wbAlmClientNurg
1.3.6.1.4.1.20044.102.2.2.1.33Nodermoac17wbAlmclientEdfaWarnings
1.3.6.1.4.1.20044.102.2.2.1.33.1Scalarrmoac17wbAlmClientGainLowWarningread-onlycurrentIL2 Gain Low Warning :This OID indicates that the Gain is lower than the Warning threshold of the IL2 Module <Help> This alarm indicates if the IL2 gain is too…
1.3.6.1.4.1.20044.102.2.2.1.33.2Scalarrmoac17wbAlmClientGainHighWarningread-onlycurrentIL2 Gain High Warning :This OID indicates that the Gain is higher than the Warning threshold of the IL2 Module <Help> This alarm indicates if the IL2 gain is t…
1.3.6.1.4.1.20044.102.2.2.1.33.3Scalarrmoac17wbAlmClientInputPwrLowWarningread-onlycurrentIL2 Rx Pwr Low Warning :This OID indicates that the Receive Power is lower than the Warning threshold of the IL2 Optical Module <Help> This warning indicates i…
1.3.6.1.4.1.20044.102.2.2.1.33.4Scalarrmoac17wbAlmClientInputPwrHighWarningread-onlycurrentIL2 Rx Pwr High Warning :This OID indicates that the Receive Power is higher than the Warning threshold of the IL2 Optical Module <Help> This warning indicates…
1.3.6.1.4.1.20044.102.2.2.1.33.5Scalarrmoac17wbAlmClientOutputPwrLowWarningread-onlycurrentIL2 Tx Pwr Low Warning :This OID indicates that the Transmit Power is lower than the Warning threshold of the IL2 Optical Module <Help> This warning indicates …
1.3.6.1.4.1.20044.102.2.2.1.33.6Scalarrmoac17wbAlmClientOutputPwrHighWarningread-onlycurrentIL2 Tx Pwr High Warning :This OID indicates that the Transmit Power is higher than the Warning threshold of the IL2 Optical Module <Help> This warning indicate…
1.3.6.1.4.1.20044.102.2.2.1.33.7Scalarrmoac17wbAlmClientBiasLowWarningread-onlycurrentIL2 Bias Low Warning :This OID indicates that the Bias is lower than the Warning threshold of the IL2 Optical Module <Help> This warning indicates if the IL2 b…
1.3.6.1.4.1.20044.102.2.2.1.33.8Scalarrmoac17wbAlmClientBiasHighWarningread-onlycurrentIL2 Bias High Warning :This OID indicates that the Bias is higher than the Warning threshold of the IL2 Optical Module <Help> This warning indicates if the IL2…
1.3.6.1.4.1.20044.102.2.2.2Nodermoac17wbAlmClientUrg
1.3.6.1.4.1.20044.102.2.2.2.32Nodermoac17wbAlmclientEdfaAlarms1
1.3.6.1.4.1.20044.102.2.2.2.32.1Scalarrmoac17wbAlmClientGainLowAlarmread-onlycurrentIL2 Gain Low Alarm :This OID indicates that the Gain is lower than the alarm threshold of the IL2 Module <Help> This alarm indicates if the IL2 gain is too low…
1.3.6.1.4.1.20044.102.2.2.2.32.2Scalarrmoac17wbAlmClientGainHighAlarmread-onlycurrentIL2 Gain High Alarm :This OID indicates that the Gain is higher than the alarm threshold of the IL2 Module <Help> This alarm indicates if the IL2 gain is too h…
1.3.6.1.4.1.20044.102.2.2.2.32.3Scalarrmoac17wbAlmClientInputPwrLowAlarmread-onlycurrentIL2 Rx Pwr Low Alarm :This OID indicates that the Receive Power is lower than the alarm threshold of the IL2 Optical Module <Help> This alarm indicates if the …
1.3.6.1.4.1.20044.102.2.2.2.32.4Scalarrmoac17wbAlmClientInputPwrHighAlarmread-onlycurrentIL2 Rx Pwr High Alarm :This OID indicates that the Receive Power is higher than the alarm threshold of the IL2 Optical Module <Help> This alarm indicates if th…
1.3.6.1.4.1.20044.102.2.2.2.32.5Scalarrmoac17wbAlmClientOutputPwrLowAlarmread-onlycurrentIL2 Tx Pwr Low Alarm :This OID indicates that the Transmit Power is lower than the alarm threshold of the IL2 Optical Module <Help> This alarm indicates if the…
1.3.6.1.4.1.20044.102.2.2.2.32.6Scalarrmoac17wbAlmClientOutputPwrHighAlarmread-onlycurrentIL2 Tx Pwr High Alarm :This OID indicates that the Transmit Power is higher than the alarm threshold of the IL2 Optical Module <Help> This alarm indicates if t…
1.3.6.1.4.1.20044.102.2.2.2.32.7Scalarrmoac17wbAlmClientBiasLowAlarmread-onlycurrentIL2 Bias Low Alarm :This OID indicates that the Bias is lower than the alarm threshold of the IL2 Optical Module <Help> This alarm indicates if the IL2 bias is…
1.3.6.1.4.1.20044.102.2.2.2.32.8Scalarrmoac17wbAlmClientBiasHighAlarmread-onlycurrentIL2 Bias High Alarm :This OID indicates that the Bias is higher than the alarm threshold of the IL2 Optical Module <Help> This alarm indicates if the IL2 bias …
1.3.6.1.4.1.20044.102.2.2.3Nodermoac17wbAlmClientCrit
1.3.6.1.4.1.20044.102.2.2.3.8Nodermoac17wbAlmsynthAlm8
1.3.6.1.4.1.20044.102.2.2.3.8.4Scalarrmoac17wbAlmClientHwFailread-onlycurrentClient Port HW Failure :This OID indicates a failure on Client port, most probably caused by a HW issue <Condtype> CLIENT_HW_FAIL <Probcause> equipmentMalfunct…
1.3.6.1.4.1.20044.102.2.2.3.8.5Scalarrmoac17wbAlmClientTxOffread-onlycurrentIL2 Optical Output Shutdown :This OID indicates the IL2 optical output power is on <Help> This status indicates if the IL2 laser pump transceiver laser is ON o…
1.3.6.1.4.1.20044.102.2.2.3.8.9Scalarrmoac17wbAlmClientDdmWarningread-onlycurrentWarning On IL2 DDM :This OID indicates a warning is present coming out of the IL2 DDM <Help> This alarm indicates if a DDM Warning has been detected on the IL2…
1.3.6.1.4.1.20044.102.2.2.3.8.10Scalarrmoac17wbAlmClientDdmAlmread-onlycurrentAlarm On IL2 DDM :This OID indicates an alarm is present coming out of the Pre_Amp DDM <Help> This alarm indicates if a DDM Alarm has been detected on the IL2 …
1.3.6.1.4.1.20044.102.2.2.3.8.12Scalarrmoac17wbAlmClientFailread-onlycurrentClient Port Failure :This OID indicates a failure on the Client port <Condtype> CLIENT_FAIL <Probcause> bandwidthReduced(4) <Alarmtype> synthesisAlarm (12) <Po…
1.3.6.1.4.1.20044.102.2.2.3.8.13Scalarrmoac17wbAlmClientExtPumpFailread-onlycurrentIL2 External Pump Fail :This OID indicates that the external pump linked to the IL2 is in fail condition <Help> This alarm indicates if the external pump linke…
1.3.6.1.4.1.20044.102.2.2.3.8.14Scalarrmoac17wbAlmSupvbFailread-onlycurrent: <Condtype> SUPVB_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> equipmentAlarm (5) <Polarity> (2)
1.3.6.1.4.1.20044.102.2.2.3.35Nodermoac17wbAlmclientEdfaAlarms2
1.3.6.1.4.1.20044.102.2.2.3.35.1Scalarrmoac17wbAlmClientEdfaNrread-onlycurrentIL2 Optical Module Not Ready :This OID indicates that the IL2 Optical Module is not ready <Help> This status indicates if the IL2 has been correctly initialize…
1.3.6.1.4.1.20044.102.2.2.3.35.2Scalarrmoac17wbAlmClientEdfaTecFailread-onlycurrentIL2 TEC Fail :This OID indicates that the TEC is in fail condition on the IL2 Optical Module <Help> This alarm indicates if the TEC of the IL2 is in fail condi…
1.3.6.1.4.1.20044.102.2.2.3.35.3Scalarrmoac17wbAlmClientEdfaLaserFailread-onlycurrentIL2 Pump Laser Fail :This OID indicates a Transmit Laser Fail on the IL2 Optical Module <Help> This alarm indicates if the laser of the IL2 is in fail conditio…
1.3.6.1.4.1.20044.102.2.2.3.35.4Scalarrmoac17wbAlmClientEdfaLosread-onlycurrentIL2 Loss Of Signal :This OID indicates a Loss of Signal on the IL2 Optical Module <Help> This alarm indicates if an optical signal is detected on the IL2 input…
1.3.6.1.4.1.20044.102.2.2.3.35.5Scalarrmoac17wbAlmClientExtPumpEdfaLowCurrentread-onlycurrentIL2 Pump Low Current :This OID indicates that the EDFA pump current of IL2 is too low because of the external pump high power<Help> This alarm (only active whe…
1.3.6.1.4.1.20044.102.2.2.3.35.6Scalarrmoac17wbAlmClientGainOutOfRangeread-onlycurrentIL2 Gain Out Of Range :This OID indicates the target gain of the IL2 is out of range (18-32dB), the flatness of the IL1 is not guaranteed.<Help> This alarm ind…
1.3.6.1.4.1.20044.102.2.2.3.37Nodermoac17wbAlmclientMsaAlarms
1.3.6.1.4.1.20044.102.2.2.3.37.1Scalarrmoac17wbAlmClientMsaLosread-onlycurrentIL2 MSA Loss Of Signal :This OID indicates a Loss of Signal is detected on the Mid Stage Access of the IL2 EDFAThis alarm indicates a Loss of Signal is detecte…
1.3.6.1.4.1.20044.102.2.2.3.37.2Scalarrmoac17wbAlmClientMsaAttenuationread-onlycurrentIL2 MSA Attenuation Alarm :This OID indicates the attenuation on the IL2 Mid Stage access has changed.This alarm indicates the attenuation on the IL2 Mid Stage…
1.3.6.1.4.1.20044.102.2.3Nodermoac17wbAlmLine
1.3.6.1.4.1.20044.102.2.3.1Nodermoac17wbAlmLineNurg
1.3.6.1.4.1.20044.102.2.3.1.41Nodermoac17wbAlmlineEdfaWarnings
1.3.6.1.4.1.20044.102.2.3.1.41.1Scalarrmoac17wbAlmLineGainLowWarningread-onlycurrentIL1 Gain Low Warning :This OID indicates that the Gain is lower than the Warning threshold of the IL1 Module <Help> This alarm indicates if the IL1 gain is too…
1.3.6.1.4.1.20044.102.2.3.1.41.2Scalarrmoac17wbAlmLineGainHighWarningread-onlycurrentIL1 Gain High Warning :This OID indicates that the Gain is higher than the Warning threshold of the IL1 Module <Help> This alarm indicates if the IL1 gain is t…
1.3.6.1.4.1.20044.102.2.3.1.41.3Scalarrmoac17wbAlmLineInputPwrLowWarningread-onlycurrentIL1 Rx Pwr Low Warning :This OID indicates that the Receive Power is lower than the Warning threshold of the IL1 Optical Module <Help> This warning indicates i…
1.3.6.1.4.1.20044.102.2.3.1.41.4Scalarrmoac17wbAlmLineInputPwrHighWarningread-onlycurrentIL1 Rx Pwr High Warning :This OID indicates that the Receive Power is higher than the Warning threshold of the IL1 Optical Module <Help> This warning indicates…
1.3.6.1.4.1.20044.102.2.3.1.41.5Scalarrmoac17wbAlmLineOutputPwrLowWarningread-onlycurrentIL1 Tx Pwr Low Warning :This OID indicates that the Transmit Power is lower than the Warning threshold of the IL1 Optical Module <Help> This warning indicates …
1.3.6.1.4.1.20044.102.2.3.1.41.6Scalarrmoac17wbAlmLineOutputPwrHighWarningread-onlycurrentIL1 Tx Pwr High Warning :This OID indicates that the Transmit Power is higher than the Warning threshold of the IL1 Optical Module <Help> This warning indicate…
1.3.6.1.4.1.20044.102.2.3.1.41.7Scalarrmoac17wbAlmLineBiasLowWarningread-onlycurrentIL1 Bias Low Warning :This OID indicates that the Bias is lower than the Warning threshold of the IL1 Optical Module <Help> This warning indicates if the IL1 b…
1.3.6.1.4.1.20044.102.2.3.1.41.8Scalarrmoac17wbAlmLineBiasHighWarningread-onlycurrentIL1 Bias High Warning :This OID indicates that the Bias is higher than the Warning threshold of the IL1 Optical Module <Help> This warning indicates if the IL1…
1.3.6.1.4.1.20044.102.2.3.2Nodermoac17wbAlmLineUrg
1.3.6.1.4.1.20044.102.2.3.2.40Nodermoac17wbAlmlineEdfaAlarms1
1.3.6.1.4.1.20044.102.2.3.2.40.1Scalarrmoac17wbAlmLineGainLowAlarmread-onlycurrentIL1 Gain Low Alarm :This OID indicates that the Gain is lower than the alarm threshold of the IL1 Module <Help> This alarm indicates if the IL1 gain is too low…
1.3.6.1.4.1.20044.102.2.3.2.40.2Scalarrmoac17wbAlmLineGainHighAlarmread-onlycurrentIL1 Gain High Alarm :This OID indicates that the Gain is higher than the alarm threshold of the IL1 Module <Help> This alarm indicates if the IL1 gain is too h…
1.3.6.1.4.1.20044.102.2.3.2.40.3Scalarrmoac17wbAlmLineInputPwrLowAlarmread-onlycurrentIL1 Rx Pwr Low Alarm :This OID indicates that the Receive Power is lower than the alarm threshold of the IL1 Optical Module <Help> This alarm indicates if the …
1.3.6.1.4.1.20044.102.2.3.2.40.4Scalarrmoac17wbAlmLineInputPwrHighAlarmread-onlycurrentIL1 Rx Pwr High Alarm :This OID indicates that the Receive Power is higher than the alarm threshold of the IL1 Optical Module <Help> This alarm indicates if th…
1.3.6.1.4.1.20044.102.2.3.2.40.5Scalarrmoac17wbAlmLineOutputPwrLowAlarmread-onlycurrentIL1 Tx Pwr Low Alarm :This OID indicates that the Transmit Power is lower than the alarm threshold of the IL1 Optical Module <Help> This alarm indicates if the…
1.3.6.1.4.1.20044.102.2.3.2.40.6Scalarrmoac17wbAlmLineOutputPwrHighAlarmread-onlycurrentIL1 Tx Pwr High Alarm :This OID indicates that the Transmit Power is higher than the alarm threshold of the IL1 Optical Module <Help> This alarm indicates if t…
1.3.6.1.4.1.20044.102.2.3.2.40.7Scalarrmoac17wbAlmLineBiasLowAlarmread-onlycurrentIL1 Bias Low Alarm :This OID indicates that the Bias is lower than the alarm threshold of the IL1 Optical Module <Help> This alarm indicates if the IL1 bias is…
1.3.6.1.4.1.20044.102.2.3.2.40.8Scalarrmoac17wbAlmLineBiasHighAlarmread-onlycurrentIL1 Bias High Alarm :This OID indicates that the Bias is higher than the alarm threshold of the IL1 Optical Module <Help> This alarm indicates if the IL1 bias …
1.3.6.1.4.1.20044.102.2.3.3Nodermoac17wbAlmLineCrit
1.3.6.1.4.1.20044.102.2.3.3.7Nodermoac17wbAlmsynthAlm7
1.3.6.1.4.1.20044.102.2.3.3.7.4Scalarrmoac17wbAlmLineHwFailread-onlycurrentLine Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue <Condtype> LINE_HW_FAIL <Probcause> equipmentMalfunction (1…
1.3.6.1.4.1.20044.102.2.3.3.7.5Scalarrmoac17wbAlmLineTxOffread-onlycurrentIL1 Optical Output Shutdown :This OID indicates the IL1 optical output power is on <Help> This status indicates if the IL1 laser pump is ON or OFF <Condtype> L…
1.3.6.1.4.1.20044.102.2.3.3.7.9Scalarrmoac17wbAlmLineDdmWarningread-onlycurrentWarning On IL1 DDM :This OID indicates a warning is present coming out of the IL1 DDM <Help> This alarm indicates if a DDM Warning has been detected on the IL1…
1.3.6.1.4.1.20044.102.2.3.3.7.10Scalarrmoac17wbAlmLineDdmAlmread-onlycurrentAlarm On IL1 DDM :This OID indicates an alarm is present coming out of the IL1 DDM <Help> This alarm indicates if a DDM Alarm has been detected on the IL1 <Con…
1.3.6.1.4.1.20044.102.2.3.3.7.12Scalarrmoac17wbAlmLineFailread-onlycurrentLine Port Failure :This OID indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> callEstablishmentError(5) <Alarmtype> synthesisAlarm (12) <Po…
1.3.6.1.4.1.20044.102.2.3.3.7.13Scalarrmoac17wbAlmLineExtPumpFailread-onlycurrentIL1 External Pump Fail :This OID indicates that the external pump linked to the IL1 is in fail condition <Help> This alarm indicates if the external pump linke…
1.3.6.1.4.1.20044.102.2.3.3.7.14Scalarrmoac17wbAlmSupvaFailread-onlycurrent: <Condtype> SUPVA_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> equipmentAlarm (5) <Polarity> (2)
1.3.6.1.4.1.20044.102.2.3.3.43Nodermoac17wbAlmlineEdfaAlarms2
1.3.6.1.4.1.20044.102.2.3.3.43.1Scalarrmoac17wbAlmLineEdfaNrread-onlycurrentIL1 Optical Module Not Ready :This OID indicates that the IL1 Optical Module is not ready <Help> This status indicates if the IL1 has been correctly initialize…
1.3.6.1.4.1.20044.102.2.3.3.43.2Scalarrmoac17wbAlmLineEdfaTecFailread-onlycurrentIL1 TEC Fail :This OID indicates that the TEC is in fail condition on the IL1 Optical Module <Help> This alarm indicates if the TEC of the IL1 is in fail condi…
1.3.6.1.4.1.20044.102.2.3.3.43.3Scalarrmoac17wbAlmLineEdfaLaserFailread-onlycurrentIL1 Pump Laser Fail :This OID indicates a Transmit Laser Fail on the IL1 Optical Module <Help> This alarm indicates if the laser of the IL1 is in fail conditio…
1.3.6.1.4.1.20044.102.2.3.3.43.4Scalarrmoac17wbAlmLineEdfaLosread-onlycurrentIL1 Loss Of Signal :This OID indicates a Loss of Signal on the IL1 Optical Module <Help> This alarm indicates if an optical signal is detected on the IL1 input…
1.3.6.1.4.1.20044.102.2.3.3.43.5Scalarrmoac17wbAlmLineExtPumpEdfaLowCurrentread-onlycurrentIL1 Pump Low Current :This OID indicates that the EDFA pump current of IL1 is too low because of the external pump high power<Help> This alarm (only active whe…
1.3.6.1.4.1.20044.102.2.3.3.43.6Scalarrmoac17wbAlmLineGainOutOfRangeread-onlycurrentIL1 Gain Out Of Range :This OID indicates the target gain of the IL1 is out of range (10-18dB), the flatness of the IL1 is not guaranteed.<Help> This alarm ind…
1.3.6.1.4.1.20044.102.2.3.3.45Nodermoac17wbAlmlineMsaAlarms
1.3.6.1.4.1.20044.102.2.3.3.45.1Scalarrmoac17wbAlmLineMsaLosread-onlycurrentIL1 MSA Loss Of Signal :This OID indicates a Loss of Signal is detected on the Mid Stage Access of the IL1 EDFAThis alarm indicates a Loss of Signal is detecte…
1.3.6.1.4.1.20044.102.2.3.3.45.2Scalarrmoac17wbAlmLineMsaAttenuationread-onlycurrentIL1 MSA Attenuation Alarm :This OID indicates the attenuation on the IL1 Mid Stage access has changed.This alarm indicates the attenuation on the IL2 Mid Stage…
1.3.6.1.4.1.20044.102.2.3.3.48Tablermoac17wbAlmlineOscAlarmsTablenot-accessiblecurrentList of rmoac17wbAlmlineOscAlarms Article
1.3.6.1.4.1.20044.102.2.3.3.48.1Rowrmoac17wbAlmlineOscAlarmsEntrynot-accessiblecurrentRow definition for the rmoac17wbAlmlineOscAlarms table
1.3.6.1.4.1.20044.102.2.3.3.48.1.1Columnrmoac17wbAlmlineOscAlarmsIndexread-onlycurrentIndex definition for the rmoac17wbAlmlineOscAlarms table
1.3.6.1.4.1.20044.102.2.3.3.48.1.2Columnrmoac17wbAlmLineLosPortnread-onlycurrentOSC Loss Of Signal :This OID indicates that no signal is present on the OSC <Help> This alarms indicates that no signal is present on the OSC <Condtype> LINE_L…
1.3.6.1.4.1.20044.102.2.3.3.48.1.3Columnrmoac17wbAlmLineTxOffPortnread-onlycurrentOSC Optical Output Shutdown :This OID indicates the optical output power is shutdown on OSC<Help> This alarm indicates the optical output power is shutdown on …
1.3.6.1.4.1.20044.102.2.3.3.48.1.4Columnrmoac17wbAlmLineTxFailPortnread-onlycurrentOSC Tx Fail :This OID indicates the OSC Laser is in fail condition<Help> This alarm indicates the OSC Laser is in fail condition <Condtype> LINE_TX_FAIL_1 <Pro…
1.3.6.1.4.1.20044.102.2.3.3.48.1.6Columnrmoac17wbAlmLineOosPortnread-onlycurrentOSC In Service :This OID indicates that the OSC is In Service (1) or Out or Service (2)<Help> This status indicates that the OSC is In Service or Out or Servic…
1.3.6.1.4.1.20044.102.2.3.3.48.1.10Columnrmoac17wbAlmLineWarningPortnread-onlycurrentOSC DDM Warning :This OID indicates a warning is present on OSC Tx power, Receive power or temperature<Help> This alarm indicates a warning is present on OSC T…
1.3.6.1.4.1.20044.102.2.3.3.48.1.11Columnrmoac17wbAlmLineAlmPortnread-onlycurrentOSC DDM Alarm :This alarm indicates an alarm is present on OSC Tx power, Rx power or temperature <Help> This alarm indicates an alarm is present on OSC Tx powe…
1.3.6.1.4.1.20044.102.2.3.3.49Tablermoac17wbAlmlineOscThresholdAlarmsTablenot-accessiblecurrentList of rmoac17wbAlmlineOscThresholdAlarms Article
1.3.6.1.4.1.20044.102.2.3.3.49.1Rowrmoac17wbAlmlineOscThresholdAlarmsEntrynot-accessiblecurrentRow definition for the rmoac17wbAlmlineOscThresholdAlarms table
1.3.6.1.4.1.20044.102.2.3.3.49.1.1Columnrmoac17wbAlmlineOscThresholdAlarmsIndexread-onlycurrentIndex definition for the rmoac17wbAlmlineOscThresholdAlarms table
1.3.6.1.4.1.20044.102.2.3.3.49.1.2Columnrmoac17wbAlmLineOscTxPwrLowAlarmPortnread-onlycurrentOSC Tx Power Low Alarm :This OID indicates the Tx Power of the OSC is lower than the warning threshold<Help> This alarm indicates the Tx Power of the OSC is lo…
1.3.6.1.4.1.20044.102.2.3.3.49.1.3Columnrmoac17wbAlmLineOscTxPwrHighAlarmPortnread-onlycurrentOSC Tx Power High Alarm :This OID indicates the Tx Power of the OSC is higher than the warning threshold<Help> This alarm indicates the Tx Power of the OSC is …
1.3.6.1.4.1.20044.102.2.3.3.49.1.4Columnrmoac17wbAlmLineOscTxBiasLowAlarmPortnread-onlycurrentOSC Bias Current Low Alarm :This OID indicates the OSC bias current is lower than the alarm threshold <Help> This alarm indicates the OSC bias current is lower…
1.3.6.1.4.1.20044.102.2.3.3.49.1.5Columnrmoac17wbAlmLineOscTxBiasHighAlarmPortnread-onlycurrentOSC Bias Current High Alarm :This OID indicates the OSC bias current is higher than the alarm threshold <Help> This alarm indicates the OSC bias current is hig…
1.3.6.1.4.1.20044.102.2.3.3.49.1.6Columnrmoac17wbAlmLineOscVccLowAlarmPortnread-onlycurrentOSC Vcc Low Alarm :This OID indicates the Vcc of the OSC is lower than the warning threshold<Help> This alarm indicates the Vcc of the OSC is lower than the al…
1.3.6.1.4.1.20044.102.2.3.3.49.1.7Columnrmoac17wbAlmLineOscVccHighAlarmPortnread-onlycurrentOSC Vcc High Alarm :This OID indicates the Vcc of the OSC is higher than the warning threshold<Help> This alarm indicates the Vcc of the OSC is higher than the…
1.3.6.1.4.1.20044.102.2.3.3.49.1.8Columnrmoac17wbAlmLineOscTempLowAlarmPortnread-onlycurrentOSC Temperature Low Alarm :This OID indicates the OSC temperature is lower than the alarm threshold <Help> This alarm indicates the OSC temperature is lower th…
1.3.6.1.4.1.20044.102.2.3.3.49.1.9Columnrmoac17wbAlmLineOscTempHighAlarmPortnread-onlycurrentOSC Temperature High Alarm :This OID indicates the OSC temperature is higher than the alarm threshold <Help> This alarm indicates the OSC temperature is higher…
1.3.6.1.4.1.20044.102.2.3.3.49.1.10Columnrmoac17wbAlmLineOscSpanlossLowAlarmPortnread-onlycurrentOSC Span Loss Low Alarm :This OID indicates the OSC Span Loss is 3dB lower than the span loss reference<Help> This alarm indicates the OSC Span Loss is 3dB low…
1.3.6.1.4.1.20044.102.2.3.3.49.1.11Columnrmoac17wbAlmLineOscSpanlossHighAlarmPortnread-onlycurrentOSC Span Loss High Alarm :This OID indicates the OSC Span Loss is 3dB higher than the span loss reference <Help> This alarm indicates the OSC Span Loss is 3dB …
1.3.6.1.4.1.20044.102.2.3.3.49.1.16Columnrmoac17wbAlmLineOscRxPwrLowAlarmPortnread-onlycurrentOSC Rx Power Low Alarm :This OID indicates the Rx Power of the OSC is lower than the alarm threshold<Help> This alarm indicates the Rx Power of the OSC is lowe…
1.3.6.1.4.1.20044.102.2.3.3.49.1.17Columnrmoac17wbAlmLineOscRxPwrHighAlarmPortnread-onlycurrentOSC Rx Power High Alarm :This OID indicates the Rx Power of the OSC is higher than the alarm threshold<Help> This alarm indicates the Rx Power of the OSC is hi…
1.3.6.1.4.1.20044.102.2.3.3.50Tablermoac17wbAlmlineOscThresholdsWarningsTablenot-accessiblecurrentList of rmoac17wbAlmlineOscThresholdsWarnings Article
1.3.6.1.4.1.20044.102.2.3.3.50.1Rowrmoac17wbAlmlineOscThresholdsWarningsEntrynot-accessiblecurrentRow definition for the rmoac17wbAlmlineOscThresholdsWarnings table
1.3.6.1.4.1.20044.102.2.3.3.50.1.1Columnrmoac17wbAlmlineOscThresholdsWarningsIndexread-onlycurrentIndex definition for the rmoac17wbAlmlineOscThresholdsWarnings table
1.3.6.1.4.1.20044.102.2.3.3.50.1.2Columnrmoac17wbAlmLineOscTxPwrLowWarningPortnread-onlycurrentOSC Tx Power Low Warning :This OID indicates the Tx Power of the OSC is lower than the warning threshold<Help> This alarm indicates the Tx Power of the OSC is …
1.3.6.1.4.1.20044.102.2.3.3.50.1.3Columnrmoac17wbAlmLineOscTxPwrHighWarningPortnread-onlycurrentOSC Tx Power High Warning :This OID indicates the Tx Power of the OSC is higher than the warning threshold<Help> This alarm indicates the Tx Power of the OSC i…
1.3.6.1.4.1.20044.102.2.3.3.50.1.4Columnrmoac17wbAlmLineOscTxBiasLowWarningPortnread-onlycurrentOSC Bias Current Low Warning :This OID indicates the OSC bias current is lower than the warning threshold <Help> This alarm indicates the OSC bias current is l…
1.3.6.1.4.1.20044.102.2.3.3.50.1.5Columnrmoac17wbAlmLineOscTxBiasHighWarningPortnread-onlycurrentOSC Bias Current High Warning :This OID indicates the OSC bias current is higher than the warning threshold <Help> This alarm indicates the OSC bias current is…
1.3.6.1.4.1.20044.102.2.3.3.50.1.6Columnrmoac17wbAlmLineOscVccLowWarningPortnread-onlycurrentOSC Vcc Low Warning :This OID indicates the Vcc of the OSC is lower than the warning threshold<Help> This alarm indicates the Vcc of the OSC is lower than the …
1.3.6.1.4.1.20044.102.2.3.3.50.1.7Columnrmoac17wbAlmLineOscVccHighWarningPortnread-onlycurrentOSC Vcc High Warning :This OID indicates the Vcc of the OSC is higher than the warning threshold<Help> This alarm indicates the Vcc of the OSC is higher than t…
1.3.6.1.4.1.20044.102.2.3.3.50.1.8Columnrmoac17wbAlmLineOscTempLowWarningPortnread-onlycurrentOSC Temperature Low Warning :This OID indicates the OSC temperature is lower than the warning threshold <Help> This alarm indicates the OSC temperature is lowe…
1.3.6.1.4.1.20044.102.2.3.3.50.1.9Columnrmoac17wbAlmLineOscTempHighWarningPortnread-onlycurrentOSC Temperature High Warning :This OID indicates the OSC temperature is higher than the warning threshold <Help> This alarm indicates the OSC temperature is hi…
1.3.6.1.4.1.20044.102.2.3.3.50.1.10Columnrmoac17wbAlmLineOscSpanlossLowWarningPortnread-onlycurrentOSC Span Loss Low Warning :This OID indicates the OSC Span Loss is 1dB lower than the span loss reference<Help> This alarm indicates the OSC Span Loss is 1dB l…
1.3.6.1.4.1.20044.102.2.3.3.50.1.11Columnrmoac17wbAlmLineOscSpanlossHighWarningPortnread-onlycurrentOSC Span Loss High Warning :This OID indicates the OSC Span Loss is 1dB higher than the span loss reference <Help> This alarm indicates the OSC Span Loss is 1d…
1.3.6.1.4.1.20044.102.2.3.3.50.1.16Columnrmoac17wbAlmLineOscRxPwrLowWarningPortnread-onlycurrentOSC Rx Power Low Warning :This OID indicates the Rx Power of the OSC is lower than the warning threshold<Help> This alarm indicates the Rx Power of the OSC is …
1.3.6.1.4.1.20044.102.2.3.3.50.1.17Columnrmoac17wbAlmLineOscRxPwrHighWarningPortnread-onlycurrentOSC Rx Power High Warning :This OID indicates the Rx Power of the OSC is higher than the warning threshold<Help> This alarm indicates the Rx Power of the OSC i…
1.3.6.1.4.1.20044.102.3Nodermoac17wbmeasures
1.3.6.1.4.1.20044.102.3.1Nodermoac17wbMesrOther
1.3.6.1.4.1.20044.102.3.1.80Scalarrmoac17wbMesrtempMeasread-onlycurrentModule Temperature :This OID gives the temperature of the PM (Temperature =AV_S16/256) (Unit = C) <Help> This measure gives the temperature of the module
1.3.6.1.4.1.20044.102.3.1.82Scalarrmoac17wbMesrmoduleTempMinread-onlycurrentMin Module Temperature :This OID gives the minimum temperature value of the Module (Temperature = AV_S16/256) (Unit = C) <Help> This Measure gives the minimum …
1.3.6.1.4.1.20044.102.3.1.83Scalarrmoac17wbMesrmoduleTempMaxread-onlycurrentMax Module Temperature :This OID gives the maximum temperature value of the Module (Temperature = AV_S16/256) (Unit = C) <Help> This Measure gives the maximum …
1.3.6.1.4.1.20044.102.3.2Nodermoac17wbMesrClient
1.3.6.1.4.1.20044.102.3.2.32Scalarrmoac17wbMesrclientEdfaBiasMeasread-onlycurrentIL2 Pump Laser Current :This OID gives the pump laser current of the IL2 Optical Module (Current =AV_U16/20) (Unit = mA) <Help> This measure gives the bias of …
1.3.6.1.4.1.20044.102.3.2.33Scalarrmoac17wbMesrclientEdfaTxpwrMeasread-onlycurrentIL2 Tx Power :This OID gives the transmit power value of the IL2 Optical Module (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure gives the Tx opt…
1.3.6.1.4.1.20044.102.3.2.34Scalarrmoac17wbMesrclientEdfaRxpwrMeasread-onlycurrentIL2 Rx Power :This OID gives the receive power value of the IL2 Optical Module (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure gives the Rx opti…
1.3.6.1.4.1.20044.102.3.2.35Scalarrmoac17wbMesrclientEdfaGainMeasread-onlycurrentIL2 Gain Target :This OID gives the gain value of the IL2 Module (Gain =(AV_U16-32768)*0.005) (Unit = dB) <Help> This information gives the target gain of the …
1.3.6.1.4.1.20044.102.3.2.36Scalarrmoac17wbMesrclientOscSpanLossread-onlycurrentIL2 Input Span Loss :This OID indicates the attenuation of the span connected to the IL2 input (Power =(AV_U16-32768)*0.005) (Unit = dB) <Help> This measure in…
1.3.6.1.4.1.20044.102.3.2.37Scalarrmoac17wbMesrclientOscSpanLossRefread-onlycurrentIL2 Input Span Loss Ref :This OID indicates the referenced attenuation of the span connected to the IL2 input (Used to monitor the variation of the span loss) …
1.3.6.1.4.1.20044.102.3.2.38Scalarrmoac17wbMesrclientCorrectedGainread-onlycurrentIL2 Gain :This OID gives the gain value of the IL2 Module corrected by the ASE compensation mechanism (Gain =(AV_U16-32768)*0.005) (Unit = dB) <Help> This meas…
1.3.6.1.4.1.20044.102.3.2.39Scalarrmoac17wbMesrclientMsaInputPowerread-onlycurrentIL2 MSA Rx Power :This OID indicates the input power of the Mid Stage Access of the IL2 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicate…
1.3.6.1.4.1.20044.102.3.2.40Scalarrmoac17wbMesrclientMsaOutputPowerread-onlycurrentIL2 MSA Tx Power :This OID indicates the output power of the Mid Stage Access of the IL2 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicat…
1.3.6.1.4.1.20044.102.3.2.41Scalarrmoac17wbMesrclientMsaAttenuationread-onlycurrentIL2 MSA Attenuation :This OID indicates the attenuation applied on the Mid Stage Access of the IL2 (Attenuation =(AV_U16-32768)*0.005) (Unit = dB) <Help> This …
1.3.6.1.4.1.20044.102.3.2.42Scalarrmoac17wbMesrclientMsaAttenuationRefread-onlycurrentIL2 MSA Attenuation Ref :This OID indicates the reference attenuation stored for the Mid Stage Access of the In-Line1 (Used to monitor the variation of this at…
1.3.6.1.4.1.20044.102.3.3Nodermoac17wbMesrLine
1.3.6.1.4.1.20044.102.3.3.48Scalarrmoac17wbMesrlineEdfaBiasMeasread-onlycurrentIL1 Pump Laser Current :This OID gives the pump laser current of the IL1 Optical Module (Current =AV_U16/20) (Unit = mA) <Help> This measure gives the bias of …
1.3.6.1.4.1.20044.102.3.3.49Scalarrmoac17wbMesrlineEdfaTxpwrMeasread-onlycurrentIL1 Tx Power :This OID gives the transmit power value of the IL1 Optical Module (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure gives the Tx opt…
1.3.6.1.4.1.20044.102.3.3.50Scalarrmoac17wbMesrlineEdfaRxpwrMeasread-onlycurrentIL1 Rx Power :This OID gives the receive power value of the IL1 Optical Module (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure gives the Rx opti…
1.3.6.1.4.1.20044.102.3.3.51Scalarrmoac17wbMesrlineEdfaGainMeasread-onlycurrentIL1 Gain Target :This OID gives the gain value of the IL1 Module (Gain =(AV_U16-32768)*0.005) (Unit = dB) <Help> This information gives the target gain of the …
1.3.6.1.4.1.20044.102.3.3.52Scalarrmoac17wbMesrlineOscSpanLossread-onlycurrentIL1 Input Span Loss :This OID indicates the attenuation of the span connected to the IL1 input (Power =(AV_U16-32768)*0.005) (Unit = dB) <Help> This measure in…
1.3.6.1.4.1.20044.102.3.3.53Scalarrmoac17wbMesrlineOscSpanLossRefread-onlycurrentIL1 Input Span Loss Ref :This OID indicates the referenced attenuation of the span connected to the IL1 input (Used to monitor the variation of the span loss) …
1.3.6.1.4.1.20044.102.3.3.54Scalarrmoac17wbMesrlineCorrectedGainread-onlycurrentIL1 Gain :This OID gives the gain value of the IL1 Module corrected by the ASE compensation mechanism (Gain =(AV_U16-32768)*0.005) (Unit = dB) <Help> This meas…
1.3.6.1.4.1.20044.102.3.3.55Scalarrmoac17wbMesrlineMsaInputPowerread-onlycurrentIL1 MSA Rx Power :This OID indicates the input power of the Mid Stage Access of the IL1 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicate…
1.3.6.1.4.1.20044.102.3.3.56Scalarrmoac17wbMesrlineMsaOutputPowerread-onlycurrentIL1 MSA Tx Power :This OID indicates the output power of the Mid Stage Access of the IL1 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicat…
1.3.6.1.4.1.20044.102.3.3.57Scalarrmoac17wbMesrlineMsaAttenuationread-onlycurrentIL1 MSA Attenuation :This OID indicates the attenuation applied on the Mid Stage Access of the IL1 (Attenuation =(AV_U16-32768)*0.005) (Unit = dB) <Help> This …
1.3.6.1.4.1.20044.102.3.3.58Scalarrmoac17wbMesrlineMsaAttenuationRefread-onlycurrentIL1 MSA Attenuation Ref :This OID indicates the reference attenuation stored for the Mid Stage Access of the IL1 (Used to monitor the variation of this attenua…
1.3.6.1.4.1.20044.102.3.3.64Tablermoac17wbMesrlineOscTxPowerTablenot-accessiblecurrentList of rmoac17wbMesrlineOscTxPower Article
1.3.6.1.4.1.20044.102.3.3.64.1Rowrmoac17wbMesrlineOscTxPowerEntrynot-accessiblecurrentRow definition for the rmoac17wbMesrlineOscTxPower table
1.3.6.1.4.1.20044.102.3.3.64.1.1Columnrmoac17wbMesrlineOscTxPowerIndexread-onlycurrentIndex definition for the rmoac17wbMesrlineOscTxPower table
1.3.6.1.4.1.20044.102.3.3.64.1.2Columnrmoac17wbMesrlineOscTxPowerPortnread-onlycurrentOSC Tx Power :This OID gives the transmit power value of the Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit =…
1.3.6.1.4.1.20044.102.3.3.65Tablermoac17wbMesrlineOscRxPowerTablenot-accessiblecurrentList of rmoac17wbMesrlineOscRxPower Article
1.3.6.1.4.1.20044.102.3.3.65.1Rowrmoac17wbMesrlineOscRxPowerEntrynot-accessiblecurrentRow definition for the rmoac17wbMesrlineOscRxPower table
1.3.6.1.4.1.20044.102.3.3.65.1.1Columnrmoac17wbMesrlineOscRxPowerIndexread-onlycurrentIndex definition for the rmoac17wbMesrlineOscRxPower table
1.3.6.1.4.1.20044.102.3.3.65.1.2Columnrmoac17wbMesrlineOscRxPowerPortnread-onlycurrentOSC Rx Power :This OID gives the receive power value of the Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dB…
1.3.6.1.4.1.20044.102.3.3.66Tablermoac17wbMesrlineOscBiasTablenot-accessiblecurrentList of rmoac17wbMesrlineOscBias Article
1.3.6.1.4.1.20044.102.3.3.66.1Rowrmoac17wbMesrlineOscBiasEntrynot-accessiblecurrentRow definition for the rmoac17wbMesrlineOscBias table
1.3.6.1.4.1.20044.102.3.3.66.1.1Columnrmoac17wbMesrlineOscBiasIndexread-onlycurrentIndex definition for the rmoac17wbMesrlineOscBias table
1.3.6.1.4.1.20044.102.3.3.66.1.2Columnrmoac17wbMesrlineOscBiasPortnread-onlycurrentOSC Bias :This OID gives the Laser bias value of the Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV_U16/500) (Unit = mA) <Help> This…
1.3.6.1.4.1.20044.102.3.3.67Tablermoac17wbMesrlineOscTempTablenot-accessiblecurrentList of rmoac17wbMesrlineOscTemp Article
1.3.6.1.4.1.20044.102.3.3.67.1Rowrmoac17wbMesrlineOscTempEntrynot-accessiblecurrentRow definition for the rmoac17wbMesrlineOscTemp table
1.3.6.1.4.1.20044.102.3.3.67.1.1Columnrmoac17wbMesrlineOscTempIndexread-onlycurrentIndex definition for the rmoac17wbMesrlineOscTemp table
1.3.6.1.4.1.20044.102.3.3.67.1.2Columnrmoac17wbMesrlineOscTempPortnread-onlycurrentOSC Temperature :This OID gives the Laser temperature value of the Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV_S16/256) (U…
1.3.6.1.4.1.20044.102.3.3.68Tablermoac17wbMesrlineOscVoltTablenot-accessiblecurrentList of rmoac17wbMesrlineOscVolt Article
1.3.6.1.4.1.20044.102.3.3.68.1Rowrmoac17wbMesrlineOscVoltEntrynot-accessiblecurrentRow definition for the rmoac17wbMesrlineOscVolt table
1.3.6.1.4.1.20044.102.3.3.68.1.1Columnrmoac17wbMesrlineOscVoltIndexread-onlycurrentIndex definition for the rmoac17wbMesrlineOscVolt table
1.3.6.1.4.1.20044.102.3.3.68.1.2Columnrmoac17wbMesrlineOscVoltPortnread-onlycurrentOSC Voltage :This OID gives the Voltage value of the Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV_U16/10000) (Unit = V) <Help> …
1.3.6.1.4.1.20044.102.6Nodermoac17wbcontrolsWrite
1.3.6.1.4.1.20044.102.6.1Nodermoac17wbCtrlOther
1.3.6.1.4.1.20044.102.6.1.0Nodermoac17wbCtrlsynth0
1.3.6.1.4.1.20044.102.6.1.0.1Scalarrmoac17wbCtrlConfLoadread-writecurrentLoad Configuration Tables :When set this enables loading from flash configuration1 into the module.
1.3.6.1.4.1.20044.102.6.1.0.9Scalarrmoac17wbCtrlConfFlashread-writecurrentWrite Configuration Tables :This bit saves the current configuration of the module as configuration in the flash. <Help> This control saves the customer config…
1.3.6.1.4.1.20044.102.6.1.0.13Scalarrmoac17wbCtrlConfClearread-writecurrentClear Configuration Tables :This bit clears the configuration tables from configuration in the flash. <Help> This control restores the default configuration of…
1.3.6.1.4.1.20044.102.6.1.5Nodermoac17wbCtrlswMgnt
1.3.6.1.4.1.20044.102.6.1.5.2Scalarrmoac17wbCtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the Software. This reset is traffic affecting, and the configuration of Software is reloaded on start…
1.3.6.1.4.1.20044.102.6.1.5.3Scalarrmoac17wbCtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the Software. This reset is not traffic affecting, and the configuration of the Sofwtare remains unch…
1.3.6.1.4.1.20044.102.6.1.6Nodermoac17wbCtrlsynth6
1.3.6.1.4.1.20044.102.6.1.6.1Scalarrmoac17wbCtrlCurrentGwResetread-writecurrentActive Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting.
1.3.6.1.4.1.20044.102.6.1.73Nodermoac17wbCtrlledTest
1.3.6.1.4.1.20044.102.6.1.73.1Scalarrmoac17wbCtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.102.6.1.73.2Scalarrmoac17wbCtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.102.6.1.73.3Scalarrmoac17wbCtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.102.6.1.75Nodermoac17wbCtrlmaintMode
1.3.6.1.4.1.20044.102.6.1.75.1Scalarrmoac17wbCtrlMaintenanceread-writecurrentPM Maintenance Mode :This OID sets the PM in maintenance mode <Help> This control enables the maintenance mode of the module
1.3.6.1.4.1.20044.102.6.1.76Nodermoac17wbCtrlaprRestart
1.3.6.1.4.1.20044.102.6.1.76.1Scalarrmoac17wbCtrlAprManualRestartread-writecurrentAPR Manual Restart :This OID initiates the Restart mechanism to retrieve from the APR state.<Help> This control initiates the Restart mechanism to retrieve fro…
1.3.6.1.4.1.20044.102.6.2Nodermoac17wbCtrlClient
1.3.6.1.4.1.20044.102.6.2.33Nodermoac17wbCtrlclientOscInputSpanLoss
1.3.6.1.4.1.20044.102.6.2.33.1Scalarrmoac17wbCtrlClientSpanLossread-writecurrentStore IL2 Input Span Loss :This OID stores the current input span Loss as a reference to monitor the span loss variation <Help> This parameter stores the curre…
1.3.6.1.4.1.20044.102.6.2.34Scalarrmoac17wbCtrlclientGainCstMonitorValueread-writecurrentIL2 Fiber Aging Period :This OID sets the value of the monitoring period to detect a fiber aging. (Unit = s) This value sets the monitoring period to detect a …
1.3.6.1.4.1.20044.102.6.2.36Scalarrmoac17wbCtrlclientGainSettingValueread-writecurrentIL2 Gain Target :This OID sets the value of the nominal gain of the IL2lifier Module (active only in constant output power mode) (AV=(Gain/0,005) + 32768) (Uni…
1.3.6.1.4.1.20044.102.6.2.37Nodermoac17wbCtrlclientGainProcessing
1.3.6.1.4.1.20044.102.6.2.37.1Scalarrmoac17wbCtrlClientGainProcread-writecurrentIL2 Fiber Aging Compensation :This OID initiates the automatic nominal gain adjustment on the IL2lifier Module<Help> This control initiates the automatic nomin…
1.3.6.1.4.1.20044.102.6.2.38Scalarrmoac17wbCtrlclientGainCstFiberAgingMarginValueread-writecurrentIL2 Aging Threshold :This OID sets the threshold to consider the power drop as a fiber aging. (active only in constant gain mode) (AV=(Gain/0,005) + 32768) (Un…
1.3.6.1.4.1.20044.102.6.2.40Nodermoac17wbCtrlclientMsaAttenuationValue
1.3.6.1.4.1.20044.102.6.2.40.1Scalarrmoac17wbCtrlClientAttenuationread-writecurrentStore IL2 MSA Attenuation :This OID stores the current attenuation applied on the Mid Stage Access of the IL2 (used for monitoring the MSA attenuation variatio…
1.3.6.1.4.1.20044.102.6.2.41Scalarrmoac17wbCtrlclientTlvPreviousAmpPwrWread-writecurrentPrevious Amplifier Output Power :This OID sets the value of the previous Amplifier output power to be used to compute the local span loss monitoring (AV=(Gain/…
1.3.6.1.4.1.20044.102.6.2.42Scalarrmoac17wbCtrlclientTlvPreviousRoadmLambdaNbWread-writecurrentPrevious Roadm Lambda Number :This OID sets the value of the previous Roadm wavelength number to be computed locally (Unit = Lambdas) <Help> This parameter sto…
1.3.6.1.4.1.20044.102.6.2.57Scalarrmoac17wbCtrllineTlvPreviousAmpPwrWread-writecurrentPrevious Amplifier Output Power :This OID sets the value of the previous Amplifier output power to be used to compute the local span loss monitoring (AV=(Gain/…
1.3.6.1.4.1.20044.102.6.2.58Scalarrmoac17wbCtrllineTlvPreviousRoadmLambdaNbWread-writecurrentPrevious Roadm Lambda Number :This OID sets the value of the previous Roadm wavelength number to be computed locally (Unit = Lambdas) <Help> This parameter sto…
1.3.6.1.4.1.20044.102.6.3Nodermoac17wbCtrlLine
1.3.6.1.4.1.20044.102.6.3.49Nodermoac17wbCtrllineOscInputSpanLoss
1.3.6.1.4.1.20044.102.6.3.49.1Scalarrmoac17wbCtrlLineSpanLossread-writecurrentStore IL1 Input Span Loss :This OID stores the current input span Loss as a reference to monitor the span loss variation<Help> This parameter stores the curren…
1.3.6.1.4.1.20044.102.6.3.50Scalarrmoac17wbCtrllineGainCstMonitorValueread-writecurrentIL1 Fiber Aging Period :This OID sets the value of the monitoring period to detect a fiber aging. (Unit = s) This value sets the monitoring period to detect a …
1.3.6.1.4.1.20044.102.6.3.52Scalarrmoac17wbCtrllineGainSettingValueread-writecurrentIL1 Gain Target :This OID sets the value of the nominal gain of the IL1 Module (active only in constant output power mode) (AV=(Gain/0,005) + 32768) (Unit = dB…
1.3.6.1.4.1.20044.102.6.3.53Nodermoac17wbCtrllineGainProcessing
1.3.6.1.4.1.20044.102.6.3.53.1Scalarrmoac17wbCtrlLineGainProcread-writecurrentIL1 Fiber Aging Compensation :This OID initiates the automatic nominal gain adjustment on the IL1 Module<Help> This control initiates the automatic nominal gai…
1.3.6.1.4.1.20044.102.6.3.54Scalarrmoac17wbCtrllineGainCstFiberAgingMarginValueread-writecurrentIL1 Aging Threshold :This OID sets the threshold to consider the power drop as a fiber aging. (active only in constant gain mode) (AV=(Gain/0,005) + 32768) (Un…
1.3.6.1.4.1.20044.102.6.3.56Nodermoac17wbCtrllineMsaAttenuationValue
1.3.6.1.4.1.20044.102.6.3.56.1Scalarrmoac17wbCtrlLineAttenuationread-writecurrentStore IL1 MSA Attenuation :This OID stores the current attenuation applied on the Mid Stage Access of the IL1 (used for monitoring the MSA attenuation variatio…
1.3.6.1.4.1.20044.102.7Nodermoac17wbri
1.3.6.1.4.1.20044.102.7.2Scalarrmoac17wbRinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.102.7.3Scalarrmoac17wbRinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.102.7.4Scalarrmoac17wbRinvModulePlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.102.7.5Scalarrmoac17wbRinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.102.7.6Scalarrmoac17wbRinvGwPlatformread-onlycurrentGW platform description: This OID contains the description of the gateware platform.
1.3.6.1.4.1.20044.102.7.7Tablermoac17wbRinvBoosterTablenot-accessiblecurrentList of the Boosters on the selected module
1.3.6.1.4.1.20044.102.7.7.1Rowrmoac17wbRinvBoosterEntrynot-accessiblecurrentRow definition for the Boosters table
1.3.6.1.4.1.20044.102.7.7.1.1Columnrmoac17wbRinvBoosterIndexread-onlycurrentIndex for Booster table
1.3.6.1.4.1.20044.102.7.7.1.2Columnrmoac17wbRinvBoosterread-onlycurrentInventory for the Booster: This OID contains the inventory for the Booster
1.3.6.1.4.1.20044.102.7.8Tablermoac17wbRinvPreAmpTablenot-accessiblecurrentList of the PreAmps on the selected module
1.3.6.1.4.1.20044.102.7.8.1Rowrmoac17wbRinvPreAmpEntrynot-accessiblecurrentRow definition for the PreAmp table
1.3.6.1.4.1.20044.102.7.8.1.1Columnrmoac17wbRinvPreAmpIndexread-onlycurrentIndex for PreAmp table
1.3.6.1.4.1.20044.102.7.8.1.2Columnrmoac17wbRinvPreAmpread-onlycurrentInventory for the PreAmp: This OID contains the inventory for the PreAmp
1.3.6.1.4.1.20044.102.9Nodermoac17wbConfig
1.3.6.1.4.1.20044.102.9.1Nodermoac17wbCfgNoValue
1.3.6.1.4.1.20044.102.9.1.1Nodermoac17wbtableclientStartup
1.3.6.1.4.1.20044.102.9.1.1.2Scalarrmoac17wbCfgclientEdfaLaserCtrlread-writecurrentDefault Settings on Client Laser :This OID configures the default initialisation settings on the client laser.
1.3.6.1.4.1.20044.102.9.1.1.3Scalarrmoac17wbCfgclientEdfaLaserModeread-writecurrentDefault Settings on Client mode :This OID configures the default mode on the client amplifier.
1.3.6.1.4.1.20044.102.9.1.1.4Scalarrmoac17wbCfgclientGainValueread-writecurrentDefault Settings on Client Gain :This OID configures the default gain on the client amplifier.
1.3.6.1.4.1.20044.102.9.1.1.5Scalarrmoac17wbCfgclientTiltValueread-writecurrentDefault Settings on Client Tilt :This OID configures the default tilt on the client amplifier.
1.3.6.1.4.1.20044.102.9.1.1.6Scalarrmoac17wbCfgclientMsaLossread-writecurrentDefault Settings on Client MSA :This OID configures the default MSA value on the client amplifier.
1.3.6.1.4.1.20044.102.9.1.1.7Scalarrmoac17wbCfgclientOutputPowerValueread-writecurrentDefault Settings on Client Output power :This OID configures the default Output power value on the client amplifier.
1.3.6.1.4.1.20044.102.9.1.1.8Scalarrmoac17wbCfgclientAseCompensationread-writecurrentDefault Settings on Client ASE :This OID configures the default ASE compensation value on the client amplifier.
1.3.6.1.4.1.20044.102.9.1.1.10Scalarrmoac17wbCfgclientGainHighAlarmread-writecurrentDefault setting on Gain High Alarm :This register configures the default initialisation settings on the alarm threshold
1.3.6.1.4.1.20044.102.9.1.1.11Scalarrmoac17wbCfgclientGainHighWarningread-writecurrentDefault setting on Gain High Warning :This register configures the default initialisation settings on the warning threshold
1.3.6.1.4.1.20044.102.9.1.1.12Scalarrmoac17wbCfgclientGainLowWarningread-writecurrentDefault setting on Gain Low Warning :This register configures the default initialisation settings on the warning threshold
1.3.6.1.4.1.20044.102.9.1.1.13Scalarrmoac17wbCfgclientGainLowAlarmread-writecurrentDefault setting on Gain Low Alarm :This register configures the default initialisation settings on the alarm threshold
1.3.6.1.4.1.20044.102.9.1.1.14Scalarrmoac17wbCfgclientLossOfSignalread-writecurrentDefault setting on Loss Of Signal :This register configures the default initialisation settings on the Loss Of Signal threshold
1.3.6.1.4.1.20044.102.9.2Nodermoac17wbCfgLineStartUp
1.3.6.1.4.1.20044.102.9.2.1Nodermoac17wbtablelineStartup
1.3.6.1.4.1.20044.102.9.2.1.2Scalarrmoac17wbCfglineEdfaLaserCtrlread-writecurrentDefault Settings on Line Laser :This OID configures the default initialisation settings on the line laser.
1.3.6.1.4.1.20044.102.9.2.1.3Scalarrmoac17wbCfglineEdfaLaserModeread-writecurrentDefault Settings on Line mode :This OID configures the default mode on the line amplifier.
1.3.6.1.4.1.20044.102.9.2.1.4Scalarrmoac17wbCfglineGainValueread-writecurrentDefault Settings on Line Gain :This OID configures the default gain on the line amplifier.
1.3.6.1.4.1.20044.102.9.2.1.5Scalarrmoac17wbCfglineTiltValueread-writecurrentDefault Settings on Line Tilt :This OID configures the default tilt on the line amplifier.
1.3.6.1.4.1.20044.102.9.2.1.6Scalarrmoac17wbCfglineMsaLossread-writecurrentDefault Settings on Line MSA :This OID configures the default MSA value on the line amplifier.
1.3.6.1.4.1.20044.102.9.2.1.7Scalarrmoac17wbCfglineOutputPowerValueread-writecurrentDefault Settings on Line Output power :This OID configures the default Output power value on the line amplifier.
1.3.6.1.4.1.20044.102.9.2.1.8Scalarrmoac17wbCfglineAseCompensationread-writecurrentDefault Settings on Line ASE :This OID configures the default ASE compensation value on the line amplifier.
1.3.6.1.4.1.20044.102.9.2.1.10Scalarrmoac17wbCfglineGainHighAlarmread-writecurrentDefault setting on Gain High Alarm :This register configures the default initialisation settings on the alarm threshold
1.3.6.1.4.1.20044.102.9.2.1.11Scalarrmoac17wbCfglineGainHighWarningread-writecurrentDefault setting on Gain High Warning :This register configures the default initialisation settings on the warning threshold
1.3.6.1.4.1.20044.102.9.2.1.12Scalarrmoac17wbCfglineGainLowWarningread-writecurrentDefault setting on Gain Low Warning :This register configures the default initialisation settings on the warning threshold
1.3.6.1.4.1.20044.102.9.2.1.13Scalarrmoac17wbCfglineGainLowAlarmread-writecurrentDefault setting on Gain Low Alarm :This register configures the default initialisation settings on the alarm threshold
1.3.6.1.4.1.20044.102.9.2.1.14Scalarrmoac17wbCfglineLossOfSignalread-writecurrentDefault setting on Loss Of Signal :This register configures the default initialisation settings on the Loss Of Signal threshold
1.3.6.1.4.1.20044.102.9.2.1.18Scalarrmoac17wbCfglossEnableread-writecurrentDefault setting on Loss Of Signal :This register configures the default initialisation settings on the Loss Of Signal
1.3.6.1.4.1.20044.102.9.3Nodermoac17wbCfgClientSupvStartUp
1.3.6.1.4.1.20044.102.9.3.1Tablermoac17wbCfgLineStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.102.9.3.1.1Rowrmoac17wbCfgLineStartupEntrynot-accessiblecurrentRow definition for the clientSupvStartUp table
1.3.6.1.4.1.20044.102.9.3.1.1.1Columnrmoac17wbCfgLineStartupIndexread-onlycurrentIndex definition for the lineStartup table
1.3.6.1.4.1.20044.102.9.3.1.1.3Columnrmoac17wbCfgLineOscLaserCtrlPortnread-writecurrentDefault Settings on OSC Laser :This OID configures the default initialisation settings on the OSC
1.3.6.1.4.1.20044.102.9.3.1.1.4Columnrmoac17wbCfgLineOscOosPortnread-writecurrentDefault Settings on OSC mode :This OID configures the default mode on the OSC
1.3.6.1.4.1.20044.102.9.3.1.1.5Columnrmoac17wbCfgLineOscSpanLengthPortnread-writecurrentDefault Settings on OSC span length :This OID defines the length of the span connected on the OSC port
1.3.6.1.4.1.20044.102.9.3.1.1.6Columnrmoac17wbCfgLineOscCorrectionFactorPortnread-writecurrentDefault Settings on OSC attenuation corrector factor :This OID defines the correction factor to apply on the span attenuation measure on the OSC Channel (1510)…
1.3.6.1.4.1.20044.102.9.3.1.1.11Columnrmoac17wbCfgLineSpanLossHighAlarmPortnread-writecurrentDefault setting on Span Loss High Alarm :This register configures the default initialisation settings on the alarm threshold
1.3.6.1.4.1.20044.102.9.3.1.1.12Columnrmoac17wbCfgLineSpanLossHighWarningPortnread-writecurrentDefault setting on Span Loss High Warning :This register configures the default initialisation settings on the warning threshold
1.3.6.1.4.1.20044.102.9.3.1.1.13Columnrmoac17wbCfgLineSpanLossLowWarningPortnread-writecurrentDefault setting on Span Loss Low Warning :This register configures the default initialisation settings on the warning threshold
1.3.6.1.4.1.20044.102.9.3.1.1.14Columnrmoac17wbCfgLineSpanLossLowAlarmPortnread-writecurrentDefault setting on Span Loss Low Alarm :This register configures the default initialisation settings on the alarm threshold
1.3.6.1.4.1.20044.102.9.4Nodermoac17wbCfgLabels
1.3.6.1.4.1.20044.102.9.4.1Tablermoac17wbCfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.102.9.4.1.1Rowrmoac17wbCfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.102.9.4.1.1.1Columnrmoac17wbCfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.102.9.4.1.1.3Columnrmoac17wbCfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.102.9.4.2Tablermoac17wbCfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.102.9.4.2.1Rowrmoac17wbCfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.102.9.4.2.1.1Columnrmoac17wbCfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.102.9.4.2.1.3Columnrmoac17wbCfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.102.9.257Scalarrmoac17wbCfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.102.10Nodermoac17wbtraps
1.3.6.1.4.1.20044.102.10.4Scalarrmoac17wbtrapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.102.10.34Notificationrmoac17wbLineTrapCritGoesOncurrentCritical Line default is activated
1.3.6.1.4.1.20044.102.10.35Notificationrmoac17wbLineTrapCritGoesOffcurrentCritical Line default disappeared
1.3.6.1.4.1.20044.102.10.44Notificationrmoac17wbClientTrapCritGoesOncurrentCritical client default is activated
1.3.6.1.4.1.20044.102.10.45Notificationrmoac17wbClientTrapCritGoesOffcurrentCritical client default disappeared
1.3.6.1.4.1.20044.102.10.50Notificationrmoac17wbPowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.102.10.51Notificationrmoac17wbPowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared
Type Definitions
NameSyntaxStatusDescription
Rmoac17wbaprModeINTEGER { rmoac17wbaproffmode(0), rmoac17wbaprsemiautomode(1), rmoac17wbaprautomode(2) rmoac17wbaprlossforwardingmode(3) rmoac17wbaprrepeatmode(4) }currentDifferent modes on APR
Rmoac17wbBoosterCstGainAdjModeINTEGER { rmoac17wbboostercstgainadjsemiautomode(1), rmoac17wbboostercstgainadjautomode(2) }currentDifferent modes when constant Gain
Rmoac17wbBoosterGainAdjModeINTEGER { rmoac17wbboostergainadjmanualmode(0), rmoac17wbboostergainadjsemiautomode(1), rmoac17wbboostergainadjautomode(2) }currentDifferent modes on Gain
Rmoac17wbboosterModeINTEGER { rmoac17wbboosterdefaultmode(0), rmoac17wbboosterconstantcurrentmode(1), rmoac17wbboosterconstantpowermode(2) rmoac17wbboosterconstantgainmode(3) rmoac17wbboosterpoutpinmode(4) rmoac17wbboostermanualmode(5) rmoac17wbboosterfeedforwardmode(6) rmoac17wbboostertransientsupmode(7) }currentDifferent modes on OA booster
Rmoac17wbPreAmpCstGainAdjModeINTEGER { rmoac17wbpreampcstgainadjsemiautomode(1), rmoac17wbpreampcstgainadjautomode(2) }currentDifferent modes when constant Gain
Rmoac17wbPreAmpGainAdjModeINTEGER { rmoac17wbpreampgainadjmanualmode(0), rmoac17wbpreampgainadjsemiautomode(1), rmoac17wbpreampgainadjautomode(2) }currentDifferent modes on Gain
Rmoac17wbpreampModeINTEGER { rmoac17wbpreampdefaultmode(0), rmoac17wbpreampconstantcurrentmode(1), rmoac17wbpreampconstantpowermode(2) rmoac17wbpreampconstantgainmode(3) rmoac17wbpreamppoutpinmode(4) rmoac17wbpreampmanualmode(5) rmoac17wbpreampfeedforwardmode(6) rmoac17wbpreamptransientsupmode(7) }currentDifferent modes on OA preamp