EKINOPS-Vent-MIB
54 objects
MIB for the Ekinops VENT hardware.
Imported Objects
| EKINOPS-MIB | EkiApiState EkiMeasureType EkiMode ekinops EkiOnOff EkiProtocol EkiState |
| SNMPv2-SMI | Counter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20044.83 | Identitymodulevent | MIB for the Ekinops VENT hardware. | ||
| 1.3.6.1.4.1.20044.83.2 | Nodeventalarms | |||
| 1.3.6.1.4.1.20044.83.2.1 | NodeventAlmOther | |||
| 1.3.6.1.4.1.20044.83.2.1.1 | NodeventAlmOtherNurg | |||
| 1.3.6.1.4.1.20044.83.2.1.2 | NodeventAlmOtherUrg | |||
| 1.3.6.1.4.1.20044.83.2.1.2.20 | NodeventAlmfansMgnt | |||
| 1.3.6.1.4.1.20044.83.2.1.2.20.1 | ScalarventAlmFanFail | read-only | current | Fan Unit Failed :This OID indicates a failure on one of the fans <Condtype> FAN_FAIL <Probcause> heatingVentCoolingSystemProblem (22) <Alarmtype> equipmentAlar… |
| 1.3.6.1.4.1.20044.83.2.1.2.20.2 | ScalarventAlmFan1Fail | read-only | current | Fan Unit #1 Failed :This OID indicates a failure on fan #1. <Help> This alarm indicates if the FAN #1 is in fail condition <Condtype> FAN1_FAIL <Probcause> hea… |
| 1.3.6.1.4.1.20044.83.2.1.2.20.3 | ScalarventAlmFan2Fail | read-only | current | Fan Unit #2 Failed :This OID indicates a failure on fan #2. <Help> This alarm indicates if the FAN #2 is in fail condition <Condtype> FAN2_FAIL <Probcause> hea… |
| 1.3.6.1.4.1.20044.83.2.1.2.20.5 | ScalarventAlmFanOff | read-only | current | Fan Unit OFF :This OID indicates a speed rotation value under the threshold one of the fans <Help> This alarm indicates if the FAN #4 is in fail condition <Con… |
| 1.3.6.1.4.1.20044.83.2.1.2.20.6 | ScalarventAlmFan1Off | read-only | current | Fan Unit #1 OFF :This OID indicates a speed rotation value under the threshold on fan #1 <Help> This alarm indicates if the FAN #5 is in fail condition <Condty… |
| 1.3.6.1.4.1.20044.83.2.1.2.20.7 | ScalarventAlmFan2Off | read-only | current | Fan Unit #2 OFF :This OID indicates a speed rotation value under the threshold on fan #2 <Help> This alarm indicates if the FAN #6 is in fail condition <Condty… |
| 1.3.6.1.4.1.20044.83.2.1.2.20.13 | ScalarventAlmFan1LowSpeed | read-only | current | Fan Unit #1 Low Speed :This OID indicates the fan #1 of the module is blowing at low speed <Help> This alarm indicates the fans of the PMFAN are OFF <Condtype>… |
| 1.3.6.1.4.1.20044.83.2.1.2.20.14 | ScalarventAlmFan2LowSpeed | read-only | current | Fan Unit #2 Low Speed :This OID indicates the fan #2 of the module is blowing at low speed <Help> This alarm indicates the fans of the PM FAN are blowing at lo… |
| 1.3.6.1.4.1.20044.83.2.1.2.21 | NodeventAlmmoduleTempAlarms | |||
| 1.3.6.1.4.1.20044.83.2.1.2.21.1 | ScalarventAlmModuleTempLowAlarm | read-only | current | Temperature Low Alarm :This OID indicates a low threshold temperature alarm is reached on the module <Help> This alarm indicates that the chassis temperature i… |
| 1.3.6.1.4.1.20044.83.2.1.2.21.2 | ScalarventAlmModuleTempHighAlarm | read-only | current | Temperature High Alarm :This OID indicates a high threshold temperature alarm is reached on the module <Help> This alarm indicates that the chassis temperature… |
| 1.3.6.1.4.1.20044.83.2.1.2.22 | NodeventAlmmoduleTempWarnings | |||
| 1.3.6.1.4.1.20044.83.2.1.2.22.1 | ScalarventAlmModuleTempLowWarning | read-only | current | Temperature Low Warning :This OID indicates a low threshold temperature warning is reached on the module <Help> This alarm indicates that the chassis temperatu… |
| 1.3.6.1.4.1.20044.83.2.1.2.22.2 | ScalarventAlmModuleTempHighWarning | read-only | current | Temperature High Warning :This OID indicates a high threshold temperature warning is reached on the module <Help> This alarm indicates that the chassis tempera… |
| 1.3.6.1.4.1.20044.83.2.1.3 | NodeventAlmOtherCrit | |||
| 1.3.6.1.4.1.20044.83.2.1.3.0 | NodeventAlmsynthAlm0 | |||
| 1.3.6.1.4.1.20044.83.2.1.3.0.9 | ScalarventAlmModuleGlobFailure | read-only | current | Module Failure :This OID is set on detection of a failure originating from the PM <Condtype> MODULE_GLOB_FAILURE <Probcause> equipmentMalfunction (16) <Alarmty… |
| 1.3.6.1.4.1.20044.83.2.1.3.0.11 | ScalarventAlmDefPowerA | read-only | current | Power Input A Present :This OID indicates that there is not input power on the right power connector (A). <Help> This alarm indicates if the power input A is p… |
| 1.3.6.1.4.1.20044.83.2.1.3.0.12 | ScalarventAlmDefPowerB | read-only | current | Power Input B Present :This OID indicates that there is not input power on the right power connector (B). <Help> This alarm indicates if the power input B is p… |
| 1.3.6.1.4.1.20044.83.2.1.3.0.15 | ScalarventAlmDefFuseA | read-only | current | Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition. <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerPro… |
| 1.3.6.1.4.1.20044.83.2.1.3.0.16 | ScalarventAlmDefFuseB | read-only | current | Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition. <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerPro… |
| 1.3.6.1.4.1.20044.83.3 | Nodeventmeasures | |||
| 1.3.6.1.4.1.20044.83.3.1 | NodeventMesrOther | |||
| 1.3.6.1.4.1.20044.83.3.1.20 | ScalarventMesrfan1Speed | read-only | current | Speed On Fan #1 :This OID gives the speed value of the fan #1 on the module (Speed = AV_U16) (Unit = rpm) <Help> This measure gives the speed value on fan #1 o… |
| 1.3.6.1.4.1.20044.83.3.1.21 | ScalarventMesrfan2Speed | read-only | current | Speed On Fan # 2 :This OID gives the speed value of the fan #2 on the module (Speed = AV_U16) (Unit = rpm)<Help> This measure gives the speed value on fan #2 o… |
| 1.3.6.1.4.1.20044.83.3.1.65 | ScalarventMesrtempModule | read-only | current | Module Temperature :This OID gives the temperature value of the module (Temperature = AV_S16/256) (Unit = C) <Help> This measure gives the temperature value of… |
| 1.3.6.1.4.1.20044.83.3.1.66 | ScalarventMesrmaxTempModule | read-only | current | Max Module Temperature :This OID gives the maximum temperature value of the module (Temperature = AV_S16/256) (Unit = C) <Help> This measure gives the maximum … |
| 1.3.6.1.4.1.20044.83.3.1.67 | ScalarventMesrminTempModule | read-only | current | Min Module Temperature :This OID gives the minimum temperature value of the module (Temperature = AV_S16/256) (Unit = C) <Help> This measure gives the minimum … |
| 1.3.6.1.4.1.20044.83.6 | NodeventcontrolsWrite | |||
| 1.3.6.1.4.1.20044.83.6.1 | NodeventCtrlOther | |||
| 1.3.6.1.4.1.20044.83.7 | Nodeventri | |||
| 1.3.6.1.4.1.20044.83.7.3 | ScalarventRinvHwPlatform | read-only | current | HW platform description: This OID contains the description of the Hardware platform. |
| 1.3.6.1.4.1.20044.83.9 | NodeventConfig | |||
| 1.3.6.1.4.1.20044.83.9.1 | NodeventCfgLsd | |||
| 1.3.6.1.4.1.20044.83.9.2 | NodeventCfgStartUp | |||
| 1.3.6.1.4.1.20044.83.9.2.1 | Nodeventtableother | |||
| 1.3.6.1.4.1.20044.83.9.2.1.2 | ScalarventCfglowspeedThresh | read-write | current | Fans Low Speed Threshold Temp :This register selects the temperature threshold to trigger the fans to a low speed when the temperature is reaching that thresho… |
| 1.3.6.1.4.1.20044.83.9.2.1.3 | ScalarventCfghighspeedThresh | read-write | current | Fans High Speed Threshold Temp :This register selects the temperature threshold to trigger the fans to a high speed when the temperature is reaching that thres… |
| 1.3.6.1.4.1.20044.83.9.2.1.4 | ScalarventCfgspeedRatio | read-write | current | Speed Ratio (percentage) :This register selects the speed ratio (percentage) referenced to the max speed |
| 1.3.6.1.4.1.20044.83.9.2.1.10 | ScalarventCfgspeedMgnt | read-write | current | Speed Management :This register selects the features to manage the Pmfan |
| 1.3.6.1.4.1.20044.83.9.3 | NodeventCfgLabels | |||
| 1.3.6.1.4.1.20044.83.9.257 | ScalarventCfgWriteConfiguration | read-write | current | Write configuration to module:This OID writes the complete configuration to the module |
| 1.3.6.1.4.1.20044.83.10 | Nodeventtraps | |||
| 1.3.6.1.4.1.20044.83.10.2 | ScalarventtrapBoardNumber | read-only | current | Last module which generates a trap |
| 1.3.6.1.4.1.20044.83.10.32 | NotificationventPowerTrapUrgentGoesOn | current | Urgent power default is activated | |
| 1.3.6.1.4.1.20044.83.10.33 | NotificationventPowerTrapUrgentGoesOff | current | Urgent power default disappeared | |
| 1.3.6.1.4.1.20044.83.10.34 | NotificationventPowerTrapCritGoesOn | current | Critical power default is activated | |
| 1.3.6.1.4.1.20044.83.10.35 | NotificationventPowerTrapCritGoesOff | current | Critical power default disappeared |