MIB Viewer

EKINOPS-Vent-MIB

54 objects
MIB for the Ekinops VENT hardware.
Imported Objects
EKINOPS-MIBEkiApiState EkiMeasureType EkiMode ekinops EkiOnOff EkiProtocol EkiState
SNMPv2-SMICounter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
SNMPv2-TCDisplayString TEXTUAL-CONVENTION
OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.83IdentitymoduleventMIB for the Ekinops VENT hardware.
1.3.6.1.4.1.20044.83.2Nodeventalarms
1.3.6.1.4.1.20044.83.2.1NodeventAlmOther
1.3.6.1.4.1.20044.83.2.1.1NodeventAlmOtherNurg
1.3.6.1.4.1.20044.83.2.1.2NodeventAlmOtherUrg
1.3.6.1.4.1.20044.83.2.1.2.20NodeventAlmfansMgnt
1.3.6.1.4.1.20044.83.2.1.2.20.1ScalarventAlmFanFailread-onlycurrentFan Unit Failed :This OID indicates a failure on one of the fans <Condtype> FAN_FAIL <Probcause> heatingVentCoolingSystemProblem (22) <Alarmtype> equipmentAlar…
1.3.6.1.4.1.20044.83.2.1.2.20.2ScalarventAlmFan1Failread-onlycurrentFan Unit #1 Failed :This OID indicates a failure on fan #1. <Help> This alarm indicates if the FAN #1 is in fail condition <Condtype> FAN1_FAIL <Probcause> hea…
1.3.6.1.4.1.20044.83.2.1.2.20.3ScalarventAlmFan2Failread-onlycurrentFan Unit #2 Failed :This OID indicates a failure on fan #2. <Help> This alarm indicates if the FAN #2 is in fail condition <Condtype> FAN2_FAIL <Probcause> hea…
1.3.6.1.4.1.20044.83.2.1.2.20.5ScalarventAlmFanOffread-onlycurrentFan Unit OFF :This OID indicates a speed rotation value under the threshold one of the fans <Help> This alarm indicates if the FAN #4 is in fail condition <Con…
1.3.6.1.4.1.20044.83.2.1.2.20.6ScalarventAlmFan1Offread-onlycurrentFan Unit #1 OFF :This OID indicates a speed rotation value under the threshold on fan #1 <Help> This alarm indicates if the FAN #5 is in fail condition <Condty…
1.3.6.1.4.1.20044.83.2.1.2.20.7ScalarventAlmFan2Offread-onlycurrentFan Unit #2 OFF :This OID indicates a speed rotation value under the threshold on fan #2 <Help> This alarm indicates if the FAN #6 is in fail condition <Condty…
1.3.6.1.4.1.20044.83.2.1.2.20.13ScalarventAlmFan1LowSpeedread-onlycurrentFan Unit #1 Low Speed :This OID indicates the fan #1 of the module is blowing at low speed <Help> This alarm indicates the fans of the PMFAN are OFF <Condtype>…
1.3.6.1.4.1.20044.83.2.1.2.20.14ScalarventAlmFan2LowSpeedread-onlycurrentFan Unit #2 Low Speed :This OID indicates the fan #2 of the module is blowing at low speed <Help> This alarm indicates the fans of the PM FAN are blowing at lo…
1.3.6.1.4.1.20044.83.2.1.2.21NodeventAlmmoduleTempAlarms
1.3.6.1.4.1.20044.83.2.1.2.21.1ScalarventAlmModuleTempLowAlarmread-onlycurrentTemperature Low Alarm :This OID indicates a low threshold temperature alarm is reached on the module <Help> This alarm indicates that the chassis temperature i…
1.3.6.1.4.1.20044.83.2.1.2.21.2ScalarventAlmModuleTempHighAlarmread-onlycurrentTemperature High Alarm :This OID indicates a high threshold temperature alarm is reached on the module <Help> This alarm indicates that the chassis temperature…
1.3.6.1.4.1.20044.83.2.1.2.22NodeventAlmmoduleTempWarnings
1.3.6.1.4.1.20044.83.2.1.2.22.1ScalarventAlmModuleTempLowWarningread-onlycurrentTemperature Low Warning :This OID indicates a low threshold temperature warning is reached on the module <Help> This alarm indicates that the chassis temperatu…
1.3.6.1.4.1.20044.83.2.1.2.22.2ScalarventAlmModuleTempHighWarningread-onlycurrentTemperature High Warning :This OID indicates a high threshold temperature warning is reached on the module <Help> This alarm indicates that the chassis tempera…
1.3.6.1.4.1.20044.83.2.1.3NodeventAlmOtherCrit
1.3.6.1.4.1.20044.83.2.1.3.0NodeventAlmsynthAlm0
1.3.6.1.4.1.20044.83.2.1.3.0.9ScalarventAlmModuleGlobFailureread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the PM <Condtype> MODULE_GLOB_FAILURE <Probcause> equipmentMalfunction (16) <Alarmty…
1.3.6.1.4.1.20044.83.2.1.3.0.11ScalarventAlmDefPowerAread-onlycurrentPower Input A Present :This OID indicates that there is not input power on the right power connector (A). <Help> This alarm indicates if the power input A is p…
1.3.6.1.4.1.20044.83.2.1.3.0.12ScalarventAlmDefPowerBread-onlycurrentPower Input B Present :This OID indicates that there is not input power on the right power connector (B). <Help> This alarm indicates if the power input B is p…
1.3.6.1.4.1.20044.83.2.1.3.0.15ScalarventAlmDefFuseAread-onlycurrentFuse A Fail :This OID indicates that the fuse of the power input A is in fail condition. <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerPro…
1.3.6.1.4.1.20044.83.2.1.3.0.16ScalarventAlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition. <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerPro…
1.3.6.1.4.1.20044.83.3Nodeventmeasures
1.3.6.1.4.1.20044.83.3.1NodeventMesrOther
1.3.6.1.4.1.20044.83.3.1.20ScalarventMesrfan1Speedread-onlycurrentSpeed On Fan #1 :This OID gives the speed value of the fan #1 on the module (Speed = AV_U16) (Unit = rpm) <Help> This measure gives the speed value on fan #1 o…
1.3.6.1.4.1.20044.83.3.1.21ScalarventMesrfan2Speedread-onlycurrentSpeed On Fan # 2 :This OID gives the speed value of the fan #2 on the module (Speed = AV_U16) (Unit = rpm)<Help> This measure gives the speed value on fan #2 o…
1.3.6.1.4.1.20044.83.3.1.65ScalarventMesrtempModuleread-onlycurrentModule Temperature :This OID gives the temperature value of the module (Temperature = AV_S16/256) (Unit = C) <Help> This measure gives the temperature value of…
1.3.6.1.4.1.20044.83.3.1.66ScalarventMesrmaxTempModuleread-onlycurrentMax Module Temperature :This OID gives the maximum temperature value of the module (Temperature = AV_S16/256) (Unit = C) <Help> This measure gives the maximum …
1.3.6.1.4.1.20044.83.3.1.67ScalarventMesrminTempModuleread-onlycurrentMin Module Temperature :This OID gives the minimum temperature value of the module (Temperature = AV_S16/256) (Unit = C) <Help> This measure gives the minimum …
1.3.6.1.4.1.20044.83.6NodeventcontrolsWrite
1.3.6.1.4.1.20044.83.6.1NodeventCtrlOther
1.3.6.1.4.1.20044.83.7Nodeventri
1.3.6.1.4.1.20044.83.7.3ScalarventRinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.83.9NodeventConfig
1.3.6.1.4.1.20044.83.9.1NodeventCfgLsd
1.3.6.1.4.1.20044.83.9.2NodeventCfgStartUp
1.3.6.1.4.1.20044.83.9.2.1Nodeventtableother
1.3.6.1.4.1.20044.83.9.2.1.2ScalarventCfglowspeedThreshread-writecurrentFans Low Speed Threshold Temp :This register selects the temperature threshold to trigger the fans to a low speed when the temperature is reaching that thresho…
1.3.6.1.4.1.20044.83.9.2.1.3ScalarventCfghighspeedThreshread-writecurrentFans High Speed Threshold Temp :This register selects the temperature threshold to trigger the fans to a high speed when the temperature is reaching that thres…
1.3.6.1.4.1.20044.83.9.2.1.4ScalarventCfgspeedRatioread-writecurrentSpeed Ratio (percentage) :This register selects the speed ratio (percentage) referenced to the max speed
1.3.6.1.4.1.20044.83.9.2.1.10ScalarventCfgspeedMgntread-writecurrentSpeed Management :This register selects the features to manage the Pmfan
1.3.6.1.4.1.20044.83.9.3NodeventCfgLabels
1.3.6.1.4.1.20044.83.9.257ScalarventCfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.83.10Nodeventtraps
1.3.6.1.4.1.20044.83.10.2ScalarventtrapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.83.10.32NotificationventPowerTrapUrgentGoesOncurrentUrgent power default is activated
1.3.6.1.4.1.20044.83.10.33NotificationventPowerTrapUrgentGoesOffcurrentUrgent power default disappeared
1.3.6.1.4.1.20044.83.10.34NotificationventPowerTrapCritGoesOncurrentCritical power default is activated
1.3.6.1.4.1.20044.83.10.35NotificationventPowerTrapCritGoesOffcurrentCritical power default disappeared