MIB Viewer

ELECTROLINE-COMMON-TEST-MIB

31 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.5802.1.3.1.4.4.1ScalarswModeread-writecurrentThis MIB can be used to control the software activity of the DVM - In Normal mode, the device performs as programmed. - In testOnly mode, the device stops all …
1.3.6.1.4.1.5802.1.3.1.4.4.2IdentityprodTestcurrentGroup of production tests objects related to all models
1.3.6.1.4.1.5802.1.3.1.4.4.2.1IdentityprodInventorycurrentGroup of inventory objects related to all models
1.3.6.1.4.1.5802.1.3.1.4.4.2.1.1ScalarprodInvHwTyperead-writecurrentHardware Model Identification Number. This information is used by the software to differentiate the hardware platform on which it is running. For example, the …
1.3.6.1.4.1.5802.1.3.1.4.4.2.1.2ScalarprodInvHwMinorRevread-writecurrentHardware Revision Identification Number, representing the PCB version and / or the assembly modification level.
1.3.6.1.4.1.5802.1.3.1.4.4.2.1.3ScalarprodInvHwMajorRevread-writecurrentThis information is used to represent a family of hardware revisions. Major functional changes will trigger a modification of this value
1.3.6.1.4.1.5802.1.3.1.4.4.2.1.4ScalarprodInvHwDrvRevread-writecurrentThis information is used to track any changes in the manufacturing process not covered by a PCB/Assembly revision and that have an impact on the drivers.
1.3.6.1.4.1.5802.1.3.1.4.4.2.1.5ScalarprodModelNumberread-writecurrentDisplays the private electroline model number. Displayed in human-readable format.
1.3.6.1.4.1.5802.1.3.1.4.4.2.1.10IdentityprodManufacturingInfocurrentElectroline Private sub-tree to access manufacturing information
1.3.6.1.4.1.5802.1.3.1.4.4.2.1.10.1ScalarprodMfcDateTimeread-writecurrentDate and time when this unit was tested (in a string format).
1.3.6.1.4.1.5802.1.3.1.4.4.2.1.10.2ScalarprodMfcTestSwVersionread-writecurrentVersion of the test station on which this unit was tested.
1.3.6.1.4.1.5802.1.3.1.4.4.2.2IdentityprodConfigurationcurrentElectroline production configuration branch
1.3.6.1.4.1.5802.1.3.1.4.4.2.2.1ScalarprodFormatFlashread-writecurrentThis mib triggers the formating of the last blocks of the two flash banks. These section contains the dht logs
1.3.6.1.4.1.5802.1.3.1.4.4.2.2.2ScalarprodDocsisModeread-writecurrent1 Set the Dht in DOCSIS mode 2 Set the Dht in EuroDOCSIS mode DEFAULT = 1
1.3.6.1.4.1.5802.1.3.1.4.4.2.3IdentityledsControlcurrentElectroline manufacturing test leds group
1.3.6.1.4.1.5802.1.3.1.4.4.2.3.1TableledsControlTablenot-accessiblecurrentProvides Read/Write access to Leds port.
1.3.6.1.4.1.5802.1.3.1.4.4.2.3.1.1RowledsControlEntrynot-accessiblecurrentLed Control index and value.
1.3.6.1.4.1.5802.1.3.1.4.4.2.3.1.1.1ColumnledIdread-onlycurrentIndex into the le led Control value table.
1.3.6.1.4.1.5802.1.3.1.4.4.2.3.1.1.2ColumnledStateread-writecurrentControl of the LED 0: Unknown state 1: OFF 2: ON Note: Get on this mib always return Unknown state because we cannot know internally what is the state of the l…
1.3.6.1.4.1.5802.1.3.1.4.4.2.3.1.1.3ColumnledDescread-onlycurrentGives the name of the current PortId
1.3.6.1.4.1.5802.1.3.1.4.4.3IdentityelineSpectrumAnalyzercurrentTest function related to the spectrum analyzer
1.3.6.1.4.1.5802.1.3.1.4.4.3.1IdentityplantPowercurrentTest group to calculate the total power between 2 frequencies.
1.3.6.1.4.1.5802.1.3.1.4.4.3.1.1ScalarplantPowerStartFrequencyread-writecurrentFisrt frequency of the span to calculate in Hz
1.3.6.1.4.1.5802.1.3.1.4.4.3.1.2ScalarplantPowerStopFrequencyread-writecurrentLast frequency of the span to calculate in Hz
1.3.6.1.4.1.5802.1.3.1.4.4.3.1.3ScalarplantPowerNbAverageread-writecurrentNumber of FFT to perform and average the result
1.3.6.1.4.1.5802.1.3.1.4.4.3.1.4ScalarplantPowerPowerread-onlycurrentReturn the calculated power in 0.01 dBmV. Important, this function will hang the SNMP agent. Be carrefull! Also, the RBW used will be caluclated to get as near…
1.3.6.1.4.1.5802.1.3.1.4.4.3.1.5ScalarplanPowerRBWread-onlycurrentReturn the RBW used to make the last calculation
1.3.6.1.4.1.5802.1.3.1.4.4.3.1.6ScalarplantPowerNbBinsread-onlycurrentReturn the number of bins used to make the last calculation
1.3.6.1.4.1.5802.1.3.1.4.4.4IdentityprivateStatuscurrentStatus
1.3.6.1.4.1.5802.1.3.1.4.4.4.1ScalardieTemperatureread-onlycurrentReturn the die temperature in tenth of Celsius read from the bcm chip internal temperature probe. Note that only the 3383 has this probe.
Type Definitions
NameSyntaxStatusDescription
TenthCelsiusInteger32currentThis data type represents Temperature that are normally expressed in Celsius. Units are in tenths of a Celsius; for example, 5.1 Celsius will be represented as 51.