ELECTROLINE-DHT-BATTERIES-CONTROLLER-MIB
89 objects
This set of objects monitor and control vendors battery manager that may be present and connected to the DHT. This file includes control objects and status objects.
Imported Objects
| ELECTROLINE-DHT-EXTENSIONS-MIB | dhtExtensionsMibObjects |
| RFC1213-MIB | DisplayString |
| SNMPv2-SMI | Counter32 Integer32 MODULE-IDENTITY OBJECT-TYPE |
| SNMPv2-TC | DateAndTime TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16 | IdentitybattManIdentMIB | This set of objects monitor and control vendors battery manager that may be present and connected to the DHT. This file includes control objects and status obj… | ||
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1 | NodebattManIdentObjects | |||
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.1 | ScalarbattManMonitored | read-only | mandatory | Number of battery managers connected to this NE. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.2 | TablebattManDeviceTable | not-accessible | mandatory | Table containing information about the individual battery manager being monitored. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.2.1 | RowbattManDeviceEntry | not-accessible | mandatory | List of information about each battery manager being monitored. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.2.1.1 | ColumnbattManDeviceAddress | read-only | mandatory | Index into the battManDeviceTable.Address of this device on the RS-485 path |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.2.1.2 | ColumnbattManProtocolVersion | read-only | mandatory | Version of the protocol implemented in the monitored equipment. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.2.1.3 | ColumnbattManSoftwareVersion | read-only | mandatory | The content of this field is vendor specific. The intent is to provide a text representation of the monitored device system software version. Any printable ASC… |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.2.1.4 | ColumnbattManDeviceId | read-only | mandatory | The content of this field is vendor specific. The intent is to provide manufacturer and/or product specific ASCII text information. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.2.1.5 | ColumnbattManVendorIdentity | read-only | mandatory | The content of this field is vendor specific. The intent is to provide a text representation of the battery manager vendor identity. Any printable ASCII charac… |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.2.1.6 | ColumnbattManStringVoltage | read-only | mandatory | Current string voltage configuration. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.2.1.7 | ColumnbattManBatteries | read-only | mandatory | Current number of batteries. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.2.1.8 | ColumnbattManBatteryStrings | read-only | mandatory | Current number of strings. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.2.1.9 | ColumnbattManBatteriesPerStrings | read-only | mandatory | Current number of batteries per string. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.2.1.10 | ColumnbattManVoltageSupport | read-only | mandatory | Defines if the voltage measurement is supported 1 = No support. 2 = Field is supported in this installation. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.2.1.11 | ColumnbattManTemperatureSupport | read-only | mandatory | Defines if the temperature measurement is supported 1 = No support. 2 = Field is supported in this installation. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.2.1.12 | ColumnbattManImpedanceSupport | read-only | mandatory | Defines if the impedance measurement is supported 1 = No support. 2 = Field is supported in this installation. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.2.1.13 | ColumnbattManEqualPercentSupport | read-only | mandatory | Defines if the equlization percent measurement is supported 1 = No support. 2 = Field is supported in this installation. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.2.1.14 | ColumnbattManBatteryStatusSupport | read-only | mandatory | Defines if the battery status monitoring is supported 1 = No support. 2 = Field is supported in this installation. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.2.1.15 | ColumnbattManDiagSupport | read-only | mandatory | Defines if the battery manager modules diagnostics monitoring is supported 1 = No support. 2 = Field is supported in this installation. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.2.1.16 | ColumnbattManEnvDataSupport | read-only | mandatory | Defines if the battery manager environment data is supported 1 = No support. 2 = The Environment Data table is supported in this installation. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.2.1.17 | ColumnbattManManualMeasurementSupport | read-only | mandatory | Defines if the battery manager manualy triggered measurement is supported 1 = No support. 2 = The Manual Measurement table is supported in this installation. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.3 | TablebattManStringTable | not-accessible | mandatory | Table containing strings data |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.3.1 | RowbattManStringEntry | not-accessible | mandatory | List of information about each string. Indexed by string number |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.3.1.1 | ColumnbattManStringDeviceAddress | read-only | mandatory | Index into the battManStringTable. Corresponds to battManDeviceAddress in battManDeviceTable |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.3.1.2 | ColumnbattManString | read-only | mandatory | Index into the battManStringTable. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.3.1.3 | ColumnbattManStringBatteries | read-only | mandatory | number of batteries. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.3.1.4 | ColumnbattManStringTotalVoltage | read-only | mandatory | Scaled representation of an individual string total voltage in 1/100 Volts This item requires an entry in the properties MIB. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.4 | TablebattManBatteryTable | not-accessible | mandatory | Table containing batteries data |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.4.1 | RowbattManBatteryEntry | not-accessible | mandatory | List of information about each battery. Indexed by battery number |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.4.1.1 | ColumnbattManBatteryDeviceAddress | read-only | mandatory | Index into the battManBatteryTable. Corresponds to battManDeviceAddress in battManDeviceTable |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.4.1.2 | ColumnbattManBattery | read-only | mandatory | Index into the battManBatteryTable. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.4.1.3 | ColumnbattManBatteryStringID | read-only | mandatory | id of the string that this battery belongs to. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.4.1.4 | ColumnbattManBatteryVersion | read-only | mandatory | battery module version. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.4.1.5 | ColumnbattManBatteryHwVersion | read-only | mandatory | The content of this field is vendor specific. The intent is to provide a text representation of the battery system hardware version. Any printable ASCII charac… |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.4.1.6 | ColumnbattManBatterySwVersion | read-only | mandatory | The content of this field is vendor specific. The intent is to provide a text representation of the battery system software version. Any printable ASCII charac… |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.4.1.7 | ColumnbattManBatteryVoltage | read-only | mandatory | Scaled representation of an individual battery voltage in 1/100 Volts with a range of 0 to 16.000 volts This item requires an entry in the properties MIB. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.4.1.8 | ColumnbattManBatteryTemperature | read-only | mandatory | Scaled representation of temperature in degrees C with a range of -40 to + 80 degrees C. This item requires an entry in the properties MIB. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.4.1.9 | ColumnbattManBatteryImpedance | read-only | mandatory | Scaled representation of an individual battery impedance in 1/100 mOhm with a range of 0 to 99.99 mOhm. This item requires an entry in the properties MIB. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.4.1.10 | ColumnbattManBatteryEqualizationPercent | read-only | mandatory | Reports the battery equalization percent with a range of 0 to 100%. This item requires an entry in the properties MIB. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.4.1.11 | ColumnbattManBatteryStatus | read-only | mandatory | Reports the status of the battery 1. ok 2. alarm This item requires an entry in the discrete properties MIB. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.4.1.12 | ColumnbattManBatteryDatasetID | read-only | mandatory | The DatasetID of the measurement done for this battery. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.5 | TablebattManBatteryDiagTable | not-accessible | mandatory | Table containing battery diagnostic data |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.5.1 | RowbattManBatteryDiagEntry | not-accessible | mandatory | List of diagnostic information about each battery. Indexed by battery number |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.5.1.1 | ColumnbattManBatteryDiagDeviceAddress | read-only | mandatory | Index into the battManBatteryDiagTable. Corresponds to battManDeviceAddress in battManDeviceTable |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.5.1.2 | ColumnbattManBatteryDiagModuleID | read-only | mandatory | Index into the battManBatteryDiagTable. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.5.1.3 | ColumnbattManBatteryDiagPageNumber | read-write | mandatory | the data page number. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.5.1.4 | ColumnbattManBatteryDiagPageData | read-only | mandatory | The content of this field is vendor specific. The intent is to provide a text representation of the particular information of the identified module. when an in… |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.6 | TablebattManControlTable | not-accessible | mandatory | Table containing battery managers control settings. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.6.1 | RowbattManControlEntry | not-accessible | mandatory | List of controls about each battery manager. Indexed by battManControlDeviceAddress |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.6.1.1 | ColumnbattManControlDeviceAddress | read-only | mandatory | Index into the battManControlStatusTable. Corresponds to battManDeviceAddress in battManDeviceTable |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.6.1.2 | ColumnbattManControlEqualizationSetting | read-write | mandatory | Represents the equalization status. 1 means equalization activated 2 means equalization deactivated |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.6.1.3 | ColumnbattManControlAutoInterval | read-write | mandatory | Represents the period (in hours) used to take automated measurements The value 0 deactivates the automated measurements |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.6.1.4 | ColumnbattManControlSensorsRestart | read-write | current | Restart the sensors. Reading the object returns false(2), and has no effect on the unit. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.7 | TablebattManStatusTable | not-accessible | mandatory | Table containing battery managers status data. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.7.1 | RowbattManStatusEntry | not-accessible | mandatory | List of status information about each battery manager. Indexed by battManEnvDeviceAddress |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.7.1.1 | ColumnbattManStatusDeviceAddress | read-only | mandatory | Index into the battManStatusTable. Corresponds to battManDeviceAddress in battManDeviceTable |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.7.1.2 | ColumnbattManStatusTimeToMeasurement | read-only | mandatory | Indicates the remaining time (in seconds) before next automated measurement. If the automated measurement is deactivated, then the return value is always 0. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.8 | TablebattManEnvStatusTable | not-accessible | mandatory | Table containing battery manager's Environmental Status data. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.8.1 | RowbattManEnvStatusEntry | not-accessible | mandatory | List of Environmental Status information about each battery manager. Indexed by battManEnvDeviceAddress |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.8.1.1 | ColumnbattManEnvStatusDeviceAddress | read-only | mandatory | Index into the battManEnvStatusTable. Corresponds to battManDeviceAddress in battManDeviceTable |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.8.1.2 | ColumnbattManEnvStatusTemperature | read-only | mandatory | Scaled representation of battery manager temperature in degrees C This item requires an entry in the properties MIB. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.8.1.3 | ColumnbattManEnvStatusHumidity | read-only | mandatory | Scaled representation of battery manager humidity percent. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.8.1.4 | ColumnbattManEnvStatusDryContact | read-only | mandatory | bit map that indicates the state of the dry contacts. bit set means the corresponding dry contact is closed Bits Dry Contact 0 dry contact1 1 dry contact2 2 dr… |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.9 | TablebattManManualMeasTable | not-accessible | mandatory | Table containing battery manager's Manual Measurement trigger command and response data. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.9.1 | RowbattManManualMeasEntry | not-accessible | mandatory | List of ManualMeasurement Status information about each battery manager. Indexed by battManEnvDeviceAddress |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.9.1.1 | ColumnbattManManualMeasDeviceAddress | read-only | mandatory | Index into the battManManualMeasStatusTable. Corresponds to battManDeviceAddress in battManDeviceTable |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.9.1.2 | ColumnbattManManualMeasStatusText | read-only | mandatory | Short phrase describing the manual measurement status. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.9.1.3 | ColumnbattManManualMeasStatusCode | read-only | mandatory | 0: Taking measurement now. 1: Equalizer on, the measurement will be ready in 5 minutes. 2: NACK, cannot take measurement now. 3: Waiting for controller informa… |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.9.1.4 | ColumnbattManManualMeasDatasetID | read-only | mandatory | Dataset ID of this measurement (When Status code 0 and 1 was returned by the trigger command). Reset to negative value when not applicable. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.9.1.5 | ColumnbattManManualMeasTimeToMeasurement | read-only | mandatory | (When Status code 2 was returned by the trigger command): remaining time in seconds before a measurement can be done. Reset to negative value when not applicab… |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.9.1.6 | ColumnbattManManualMeasurementTrigger | read-write | current | Measurement manual trigger command. Then check the battManManualMeasTimeToMeasurement. When read always returns false(2). |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.10 | NodebattManDeviceSettings | |||
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.10.1 | ScalarbattManDevStringVoltsSetting | read-write | mandatory | typical string voltage setting : 12,24,36,48. both of battManStringCountSetting & battManStringVoltsSetting are sent the battery manager. this object is mainta… |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.10.2 | ScalarbattManDevStringCountSetting | read-write | mandatory | the number of strings setting. both of battManStringCountSetting & battManStringVoltsSetting are sent the battery manager. this object is maintained in non-vol… |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.10.3 | ScalarbattManDevDiagnoscticsSetting | read-write | current | enable or disable modules data diagnostics process. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.11 | TablebattManBatteryLogTable | not-accessible | mandatory | Table containing batteries data |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.11.1 | RowbattManBatteryLogEntry | not-accessible | mandatory | List of information about each battery. Indexed by battery number |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.11.1.1 | ColumnbattManBattLogDeviceAddress | read-only | mandatory | Index into the battManBatteryLog. Corresponds to battManDeviceAddress in battManDeviceTable |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.11.1.2 | ColumnbattManBattLogDatasetID | read-only | mandatory | The DatasetID of the measurement done for this battery. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.11.1.3 | ColumnbattManBattLogBatteryID | read-only | mandatory | Index into the battManBatteryLog. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.11.1.4 | ColumnbattManBattLogStringID | read-only | mandatory | id of the string that this battery belongs to. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.11.1.5 | ColumnbattManBattLogVoltage | read-only | mandatory | Scaled representation of an individual battery voltage in 1/100 Volts with a range of 0 to 16.000 volts This item requires an entry in the properties MIB. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.11.1.6 | ColumnbattManBattLogTemperature | read-only | mandatory | Scaled representation of temperature in degrees C with a range of -40 to + 80 degrees C. This item requires an entry in the properties MIB. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.11.1.7 | ColumnbattManBattLogImpedance | read-only | mandatory | Scaled representation of an individual battery impedance in 1/100 mOhm with a range of 0 to 99.99 mOhm. This item requires an entry in the properties MIB. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.11.1.8 | ColumnbattManBattLogConductance | read-only | mandatory | Scaled representation of an individual battery cell conductance in in 1/100 of Siemens with a range of 6000 to 60000 Siemens (tbd) This item requires an entry … |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.16.1.11.1.9 | ColumnbattManBattLogTimestamp | read-only | mandatory | Date and time when the measurement was taken. This item requires an entry in the discrete properties MIB. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| HundredthkS | Integer32 | current | This data type represents conductance values that are normally expressed in kiloSiemens. Units are in hundredths of a kS; for example, 1.23 kS will be represented as 123. |
| HundredthmOhm | Integer32 | current | This data type represents impedance values that are normally expressed in mOhms. Units are in hundredths of a mOhm; for example, 5.12 mOhms will be represented as 512. |