ELECTROLINE-DHT-GLOBAL-FIBERNODE-MIB
66 objects
This set of objects monitor and control a GLOBAL fiber node (VTN-200) that may be present and connected to the ECMM-06. This file includes a control object, and status object.
Imported Objects
| ELECTROLINE-DHT-EXTENSIONS-MIB | dhtExtensionsMibObjects |
| RFC1213-MIB | DisplayString |
| SNMPv2-SMI | Counter32 Integer32 MODULE-IDENTITY OBJECT-TYPE |
| SNMPv2-TC | TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14 | IdentitydhtGlobalFnIdentMIB | This set of objects monitor and control a GLOBAL fiber node (VTN-200) that may be present and connected to the ECMM-06. This file includes a control object, an… | ||
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1 | NodeglobalFnIdentObjects | |||
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.1 | ScalarglobalFnNumberReturnLaser | read-only | current | Number of entries in the return laser table. A zero entry means the table does not exist and the functional area is not present in this device. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.2 | TableglobalFnReturnLaserTable | not-accessible | current | A table containing information about return lasers in a fiber node |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.2.1 | RowglobalFnReturnLaserTableEntry | not-accessible | current | A list of information about each return laser in a fiber node. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.2.1.1 | ColumnglobalFnReturnLaserIndex | read-only | current | Index into globalFnRetrunLaserTable. a VTN-200 fiber node may have 4 transmitters, numbered 1,2,3,4 in modules 1,2. each module contain two transmitters. Modul… |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.2.1.2 | ColumnglobalFnReturnLaserState | read-only | current | Report the state of this return transmitter. if the state is available, this return transmitter is plugged in the module. if the state is unavailable, this ret… |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.2.1.3 | ColumnglobalFnReturnLaserRFLevel | read-only | current | Return a laser RF Level. Units in 1 dBmV. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.2.1.4 | ColumnglobalFnReturnLaserRFControl | read-write | current | control the return laser RF path |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.2.1.5 | ColumnglobalFnReturnLaserElecAttenuator | read-write | current | Return a laser electronic attenuator value. Units in 0.5 dB. user can set a return transmitter electronic value by setting this variable. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.3 | ScalarglobalFnNumberOpticalReceiver | read-only | current | Number of entries in the optical receiver table. A zero entry means the table does not exist and the functional area is not present in the device. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.4 | ScalarglobalFnOpticalReceiverAGCState | read-only | current | Reports the optical receivers AGC state. 0 = Optical receiver1 AGC OFF;Optical receiver2 AGC OFF 1 = Optical receiver1 AGC OFF;Optical receiver2 AGC ON 2 = Opt… |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.5 | ScalarglobalFnOpticalReceiverAGCControl | read-write | current | control the FRX1 and FRX2 AGC. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.6 | TableglobalFnOpticalReceiverTable | not-accessible | current | A table containing information about Optical receivers in a fiber node |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.6.1 | RowglobalFnOpticalReceiverTableEntry | not-accessible | current | A list of information about each optical receiver in a fiber node. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.6.1.1 | ColumnglobalFnOpticalReceiverIndex | read-only | current | Index into globalFnOpticalReceiverTable. a VTN-200 fiber node may have 4 receivers, numbered 1,2,3,4 in modules 1,2. each module contain two receivers. Module1… |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.6.1.2 | ColumnglobalFnOpticalReceiverState | read-only | current | Report the state of this optical receiver. if the state is available, this optical receiver is plugged in the module. if the state is unavailable, this optical… |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.6.1.3 | ColumnglobalFnOpticalReceiverType | read-only | optional | Type of optical receiver. Some valid values are: , standard frx,low input frx. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.6.1.4 | ColumnglobalFnOpticalReceiverRFLevel | read-only | current | Return an optical receiver RF Level. Units in 1 dBmV. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.6.1.5 | ColumnglobalFnOpticalReceiverRFControl | read-write | current | Control the optical receiver RF path |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.6.1.6 | ColumnglobalFnOpticalReceiverElecAttenuator | read-write | current | Return an optical receiver electronic attenuator value. Units in 0.5 dB. user can set optical receiver electronic value by setting this variable. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.7 | ScalarglobalFnNumberWingSwitch | read-only | current | Number of wing switches in this fiber node A zero entry means the table does not exist and the functional area is not present in the device. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.8 | TableglobalFnWingSwitchTable | not-accessible | current | table containing information about wing switches in this fiber node |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.8.1 | RowglobalFnWingSwitchTableEntry | not-accessible | current | List of information about each wing switch. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.8.1.1 | ColumnglobalFnWingSwitchIndex | read-only | current | Index into the dhtGlobalFnWingSwitchTable. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.8.1.2 | ColumnglobalFnWingSwitchState | read-only | current | Reports the state of the wing switch. unavailable(0) indicate that the wing switch is unavailable. off(1) indicate that the wing switch is off. sixDb(2) indica… |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.8.1.3 | ColumnglobalFnWingSwitchControl | read-write | current | control the wing switch. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.9 | ScalarglobalFnNumberRFRouter | read-only | current | Number of RF router in this fiber node A zero entry means the table does not exist and the functional area is not present in the device. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.10 | TableglobalFnRFRouterTable | not-accessible | current | table containing information about RF routers in this fiber node |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.10.1 | RowglobalRFRouterTableEntry | not-accessible | current | List of information about each RF router. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.10.1.1 | ColumnglobalFnRFRouterIndex | read-only | current | Index into the dhtGlobalFnRFRouterTable. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.10.1.2 | ColumnglobalFnRFRouterType | read-only | current | RF router type 0 = Not Present. 1 = Router Reserved Type1. 2 = Router Reserved Type2. 3 = Router Reserved Type3. 4 = Router Reserved Type4. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.10.1.3 | ColumnglobalFnRFRouterDownstreamSwitchState | read-only | current | Reports the state of the downstream redundant & segmentation switch. unavailable(0) indicates that the switch is unavailable. redundantMode(1) indicates that t… |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.10.1.4 | ColumnglobalFnRFRouterDownstreamSwitchControl | read-write | current | control the downstream switch. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.10.1.5 | ColumnglobalFnRFRouterDownstreamControlTypeState | read-only | current | Reports the control mode of the downstream redundant & segmentation switch. remote(0) indicates that the switch is in remote mode. local(1) indicates that the … |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.10.1.6 | ColumnglobalFnRFRouterDownstreamControlTypeSetting | read-write | current | Control the downstream redundant & segmentation switch mode. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.10.1.7 | ColumnglobalFnRFRouterUptreamSwitchState | read-only | current | Reports the state of the upstream redundant & segmentation switch state. unavailable(0) indicates that the switch is unavailable. redundantMode(1) indicates th… |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.10.1.8 | ColumnglobalFnRFRouterUptreamSwitchControl | read-write | current | control the upstream switch. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.10.1.9 | ColumnglobalFnRFRouterUpstreamControlTypeState | read-only | current | Reports the control mode of the upstream redundant & segmentation switch. remote(0) indicates that the switch is in remote mode. local(1) indicates that the sw… |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.10.1.10 | ColumnglobalFnRFRouterUpstreamControlTypeSetting | read-write | current | control the mode of upstream switch. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.11 | ScalarglobalFnNumberRFPort | read-only | current | Number of entries in the RF port table. A zero entry means the table does not exist and the functional area is not present in the device. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.12 | ScalarglobalRFLinkSwitchState | read-only | current | return the RF link switch status Bit7 = Optical receiver1 RF ON/OFF State Bit6 = Optical receiver2 RF ON/OFF State Bit5 = Optical receiver3 RF ON/OFF State Bit… |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.13 | ScalarglobalReverseRFLinkSwitchState | read-only | current | return the reverse RF link switch state 0 = RF Path1 OFF :RF Path2 OFF :RF Path3 OFF 1 = RF Path1 OFF :RF Path2 OFF :RF Path3 ON 2 = RF Path1 OFF :RF Path2 ON … |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.14 | ScalarglobalReverseRFLinkSwitchControl | read-write | current | control the reverse link switch path |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.15 | TableglobalFnRFPortTable | not-accessible | current | table containing information about RF ports in this fiber node |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.15.1 | RowglobalFnRFPortTableEntry | not-accessible | current | List of information about each RF port. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.15.1.1 | ColumnglobalFnRFPortIndex | read-only | current | Index into the fnRFPortTable. This index is application specific. It can be either the nth port, or a port number. For example, a node may have 4 ports, number… |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.15.1.2 | ColumnglobalUpStreamRFLevel | read-only | current | Port Reverse RF Level. Units in 1 dBmV. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.15.1.3 | ColumnglobalFnDownStreamRFLevel | read-only | current | Port Forward RF Level. Units in 1 dBmV. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.16 | ScalarglobalFnNumberElecAttenuator | read-only | current | return the number of electronic attenuator in this fiber node. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.17 | TableglobalFnElecAttenuatorTable | not-accessible | current | A table containing information about electronic attenuator in this fiber node |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.17.1 | RowglobalFnElecAttenuatorTableEntry | not-accessible | current | A list of information about each electronic attenuator in this fiber node. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.17.1.1 | ColumnglobalFnElecAttenuatorIndex | read-only | current | Index into the dhtGlobalFnElecAttenuatorTable. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.17.1.2 | ColumnglobalFnElecAttenuatorValue | read-write | current | return the attenuator value. Units in 0.5 dB. user can set electronic attenuator value by writing this variable. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.18 | ScalarglobalFnNumberElecEqualizer | read-only | current | return the number of electronic equalizer in this fiber node. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.19 | TableglobalFnElecEqualizerTable | not-accessible | current | A table containing information about electronic equalizer in a fiber node |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.19.1 | RowglobalFnElecEqualizerTableEntry | not-accessible | current | A list of information about each electronic eqalizer in this fiber node. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.19.1.1 | ColumnglobalFnElecEqualizerIndex | read-only | current | Index into the dhtGlobalFnElecAttenuatorTable. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.19.1.2 | ColumnglobalFnElecEqualizerValue | read-write | current | return the equalizer value. Units in 0.5 dB. user can set electronic equaliser value by writing this variable. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.20 | ScalarglobalFnAGCOffsetValue | read-write | current | return the optical receivers AGC offset value. user can set AGC offset value by writing this variable. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.21 | ScalarglobalFnAGCRfLevel | read-write | current | return the optical receivers AGC RF level value. user can set AGC RF level by writing this variable. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.22 | ScalarglobalFnRfLevelOffsetValue | read-write | current | return the RF level offset value. user can set RF level offset value by writing this variable. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.23 | ScalarglobalFnTemperature | read-only | current | return the fiber node internal temperature. |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.24 | ScalarglobalFnReset | read-write | current | This object is used to reset the VTN-200 by writing 1 to it. Other values written to the object have no effect. Reading the object returns a 1, and has no effe… |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.25 | ScalarglobalFnResetFrxRtx | read-write | current | This object is used to reset all RTX and FRX modules by writing 1 to it. Other values written to the object have no effect. Reading the object returns a 1, and… |
| 1.3.6.1.4.1.5802.1.3.1.2.5.1.14.1.26 | ScalarglobalFnTypeOfPowerSupply | read-only | current | Report the type of the power supply. |