ELECTROLINE-DHT-REMOTE-SWITCH-MIB

8 objects
This set of objects controls a remote switch that may be present and connected to the DHT. This file includes a control object, and status objecy and a failsafe timer.
OIDNameAccessStatusDescription
1.3.6.1.4.1.5802.1.3.1.2.5.1.11IdentitydhtRemoteSwitchMibThis set of objects controls a remote switch that may be present and connected to the DHT. This file includes a control object, and status objecy and a failsaf…
1.3.6.1.4.1.5802.1.3.1.2.5.1.11.1NodedhtRemoteSwitchObjects
1.3.6.1.4.1.5802.1.3.1.2.5.1.11.1.1ScalardhtRemoteSwitchPresenceread-onlycurrentDefines if a switch is connected to the DHT. True(1) = Remote switch present. False(2) = Remote switch not present.
1.3.6.1.4.1.5802.1.3.1.2.5.1.11.1.11NodedhtRemoteSwitchManagement
1.3.6.1.4.1.5802.1.3.1.2.5.1.11.1.11.1ScalardhtRemoteSwitchControlread-writecurrentEquipment control 1 = Turns the switch to the OFF position 2 = Turns the switch to the ON position Default: Off(1)
1.3.6.1.4.1.5802.1.3.1.2.5.1.11.1.11.2ScalardhtRemoteSwitchAutoStopTimerread-writecurrentDefines the maximum ON time in minutes for the remote switch. Reset internal timer every time the switch is turned to the ON position with dhtRemoteSwitchContr…
1.3.6.1.4.1.5802.1.3.1.2.5.1.11.1.11.3ScalardhtRemoteSwitchStatusread-onlycurrentReturns values related to the switch's status signal. 1 = Switch is ON (as per switch status signal) 2 = Switch is OFF (as per switch status signal) 3 = A stat…
1.3.6.1.4.1.5802.1.3.1.2.5.1.11.1.11.4ScalardhtRemoteSwitchOnTimeread-writecurrentCounts the amount of time in minutes the switch is ON. Writing 0 resets the counter. This object is set to 0 every time the DHT reboots (power cycle, sleep mod…