MIB Viewer

ELECTROLINE-DHT-TEST-MIB

37 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.5802.1.3.1.2.4.1NodedhtTest
1.3.6.1.4.1.5802.1.3.1.2.4.1.1NodedhtAnalogPorts
1.3.6.1.4.1.5802.1.3.1.2.4.1.1.1TablecurrentAnalogValueTablenot-accessiblecurrentProvide Read access to Analog Ports
1.3.6.1.4.1.5802.1.3.1.2.4.1.1.1.1RowcurrentAnalogValueEntrynot-accessiblecurrentAnalog port index and value
1.3.6.1.4.1.5802.1.3.1.2.4.1.1.1.1.1ColumnanalogPortIdread-onlycurrentIndex into analog value table, all analog ports are enumerated together starting at zero.
1.3.6.1.4.1.5802.1.3.1.2.4.1.1.1.1.2ColumnanalogValueread-onlycurrentReturns the current value of the analog port. When calibrated, the displayed value is in the unit used for the calibration settings.
1.3.6.1.4.1.5802.1.3.1.2.4.1.1.1.1.3ColumnanalogPortIdDescread-onlycurrentReturns the name of the current PortId
1.3.6.1.4.1.5802.1.3.1.2.4.1.1.2ScalaranalogCalibrationValueread-writecurrentCalibration value for portID
1.3.6.1.4.1.5802.1.3.1.2.4.1.1.3ScalaranalogPortToCalibrateread-writecurrentportID to calibrate: Writes analogCalibrationValue first then sets associated portID. The analogCalibrationCommit must be set after all ports are calibrated to…
1.3.6.1.4.1.5802.1.3.1.2.4.1.1.4ScalaranalogCalibrationCommitread-writecurrentMust be set to 1 after all ports are calibrated in order to store the values in non-volatile memory. The Read command always returns the value 0.
1.3.6.1.4.1.5802.1.3.1.2.4.1.1.5ScalaranalogCalibrationSetDefaultread-writecurrentSet this MIB to 1 to reset all the calibration values to the factory default.
1.3.6.1.4.1.5802.1.3.1.2.4.1.1.6TablecurrentCalibrationValueTablenot-accessiblecurrentProvides Read access to Analog Calibration Table.
1.3.6.1.4.1.5802.1.3.1.2.4.1.1.6.1RowcurrentCalibrationValueEntrynot-accessiblecurrentDisplays the stored analog calibration table content.
1.3.6.1.4.1.5802.1.3.1.2.4.1.1.6.1.1ColumnanalogCalibrationPortIdread-onlycurrentIndex into analog value table. Each analog port has an entry in the calibration table.
1.3.6.1.4.1.5802.1.3.1.2.4.1.1.6.1.2ColumnrawValueread-onlycurrentReturns a rawValue that corresponds to the calibrated value.
1.3.6.1.4.1.5802.1.3.1.2.4.1.1.6.1.3ColumncalibratedValueread-onlycurrentReturns the real display value at calibration time.
1.3.6.1.4.1.5802.1.3.1.2.4.1.1.6.1.4ColumncalibratedPortIdDescread-onlycurrentReturns the name of the current PortId.
1.3.6.1.4.1.5802.1.3.1.2.4.1.2NodedhtDigitalPorts
1.3.6.1.4.1.5802.1.3.1.2.4.1.2.1TablecurrentDigitalStatusTablenot-accessiblecurrentProvides Read access to Digital Status (Input)Ports.
1.3.6.1.4.1.5802.1.3.1.2.4.1.2.1.1RowcurrentDigitalStatusEntrynot-accessiblecurrentDigital Status (Input) port index and value.
1.3.6.1.4.1.5802.1.3.1.2.4.1.2.1.1.1ColumnstatusPortIdread-onlycurrentIndex into digital Status value table. All digital ports are enumerated together starting at zero.
1.3.6.1.4.1.5802.1.3.1.2.4.1.2.1.1.2ColumnstatusValueread-onlycurrentCurrent value of the port 0: Unknown state (read error) 1: OFF (Inactive) 2: ON (Active) Note that inverse polarity is taken into account.
1.3.6.1.4.1.5802.1.3.1.2.4.1.2.1.1.3ColumnstatusPortIdDescread-onlycurrentReturns the name of the current PortId.
1.3.6.1.4.1.5802.1.3.1.2.4.1.2.2TablecurrentDigitalControlTablenot-accessiblecurrentProvides Read/Write access to Digital Control (output) Ports.
1.3.6.1.4.1.5802.1.3.1.2.4.1.2.2.1RowcurrentDigitalControlEntrynot-accessiblecurrentDigital Control (output) port index and value.
1.3.6.1.4.1.5802.1.3.1.2.4.1.2.2.1.1ColumncontrolPortIdread-onlycurrentIndex into digital Control value table. All digital ports are enumerated together starting at zero.
1.3.6.1.4.1.5802.1.3.1.2.4.1.2.2.1.2ColumncontrolValueread-writecurrentCurrent value of the digital port 0: Unknown state (Read Error) 1: OFF (Inactive) 2: ON (Active) Note that inverse polarity is taken into account.
1.3.6.1.4.1.5802.1.3.1.2.4.1.2.2.1.3ColumncontrolPortIdDescread-onlycurrentGives the name of the current PortId
1.3.6.1.4.1.5802.1.3.1.2.4.1.3NodedhtMicroControllers
1.3.6.1.4.1.5802.1.3.1.2.4.1.3.1ScalarusmFirmwareVersionread-onlycurrentID & version of the USM micro-controller. The MSB byte represents the firmware ID and the LSB byte the revision number. Unavailable indicates a communication p…
1.3.6.1.4.1.5802.1.3.1.2.4.1.3.2ScalarbatFirmwareVersionread-onlycurrentID & version of the Battery micro-controller. The MSB byte represents the firmware ID and the LSB byte the revision number. Unavailable indicates a communicati…
1.3.6.1.4.1.5802.1.3.1.2.4.1.3.3Scalarresetread-writecurrentThe Read command returns the last DHT reset cause as follows: 0: Unknown reset cause (= error while reading). 1: Power On reset 2: Hard reset 3: Soft reset 4: …
1.3.6.1.4.1.5802.1.3.1.2.4.1.3.4ScalarwakeUpVoltageread-writecurrentThis is the battery voltage at which the DHT automatically wakes up when a shutdown is requested. The specified voltage units must match the calibrated units f…
1.3.6.1.4.1.5802.1.3.1.2.4.1.3.5ScalarwakeUpPortIdread-writecurrentEnter the portID corresponding to the battery to be monitored. When its voltage rises above the wakeUpVoltage, the DHT restarts. Note that although this was de…
1.3.6.1.4.1.5802.1.3.1.2.4.1.4NodedhtExternalDevices
1.3.6.1.4.1.5802.1.3.1.2.4.1.4.1ScalarspiExternalTestread-onlycurrentSpiExternalTest returns 1 if an Spi Communication test has failed. The value 2 is returned if an Spi Communication test has passed.
1.3.6.1.4.1.5802.1.3.1.2.4.1.4.2ScalarcprTestread-onlycurrentCprTest returns 1 if an Spi Communication test has failed. The value 2 is returned if an CprTest has passed.