MIB Viewer

ELH100-MIB

130 objects
No module-level DESCRIPTION found.
Imported Objects
RFC-1212OBJECT-TYPE
RFC1155-SMICounter enterprises IpAddress
RFC1213-MIBDisplayString PhysAddress
OIDNameAccessStatusDescription
1.3.6.1.4.1.52Nodecabletron
1.3.6.1.4.1.52.259NodecabletronOEM
1.3.6.1.4.1.52.259.10NodecabletronRepeaters
1.3.6.1.4.1.52.259.10.3NodecabletronELH100
1.3.6.1.4.1.52.259.10.3.1NodecabletronELH100Common
1.3.6.1.4.1.52.259.10.3.1.1Nodeelh100System
1.3.6.1.4.1.52.259.10.3.1.1.1Scalarelh100MajorVerread-onlymandatorySoftware major version
1.3.6.1.4.1.52.259.10.3.1.1.2Scalarelh100MinorVerread-onlymandatorySoftware minor version
1.3.6.1.4.1.52.259.10.3.1.1.3Scalarelh100HardwareVerread-onlymandatoryHardware version of system board
1.3.6.1.4.1.52.259.10.3.1.2Nodeelh100CommunityMgt
1.3.6.1.4.1.52.259.10.3.1.2.3Tableelh100CommunityTablenot-accessiblemandatoryCommunity table
1.3.6.1.4.1.52.259.10.3.1.2.3.1Rowelh100CommunityEntrynot-accessiblemandatory
1.3.6.1.4.1.52.259.10.3.1.2.3.1.1Columnelh100CommunityIndexread-onlymandatoryIndex in community table.
1.3.6.1.4.1.52.259.10.3.1.2.3.1.2Columnelh100CommunityRowCreationread-writemandatoryThe status of this row entry. Before add a row into table, it should be created first. Set Valid(1) to a row will create this row. To delete a row from this ta…
1.3.6.1.4.1.52.259.10.3.1.2.3.1.3Columnelh100CommunityStringread-writemandatoryThe community string that is required for any requests coming from this host. The default value for this object is 'public'.
1.3.6.1.4.1.52.259.10.3.1.2.3.1.4Columnelh100CommunityStatusread-writemandatoryAccess mode of the community.
1.3.6.1.4.1.52.259.10.3.1.3Nodeelh100TrapManagerMgt
1.3.6.1.4.1.52.259.10.3.1.3.2Tableelh100TrapManagerTablenot-accessiblemandatoryA list of IP trap destination entries.
1.3.6.1.4.1.52.259.10.3.1.3.2.1Rowelh100TrapMgtEntrynot-accessiblemandatoryA destination entry which defines the IP address to which traps are sent for a community.
1.3.6.1.4.1.52.259.10.3.1.3.2.1.1Columnelh100TrapMgtIndexread-onlymandatoryA value that uniquely identifies this IPTrap Entry.
1.3.6.1.4.1.52.259.10.3.1.3.2.1.2Columnelh100TrapMgtRowCreationread-writemandatoryThe status of this row entry. Before add a row into table, it should be created first. Set valid(1) to a row will create this row. To delete a row from this ta…
1.3.6.1.4.1.52.259.10.3.1.3.2.1.3Columnelh100TrapMgtCommunityStringread-writemandatoryA community name to which this destination IP address belongs.
1.3.6.1.4.1.52.259.10.3.1.3.2.1.4Columnelh100TrapMgtIpAddressread-writemandatoryThe IP address to send traps to on behalf of this entry.
1.3.6.1.4.1.52.259.10.3.1.4Nodeelh100DownloadMgt
1.3.6.1.4.1.52.259.10.3.1.4.1Scalarelh100DownloadServerIPread-writemandatoryThe file server of the download file
1.3.6.1.4.1.52.259.10.3.1.4.2Scalarelh100DownloadFilenameread-writemandatoryThe file name to download
1.3.6.1.4.1.52.259.10.3.1.4.3Scalarelh100DownloadModeread-writemandatoryPermanent upgrade stores download software into permanent storage of the agent device. Temporary upgrade just put download software in RAM, often for a test on…
1.3.6.1.4.1.52.259.10.3.1.4.4Scalarelh100DownloadActionread-writemandatoryelh100DownloadAction triggers the download operation. The run option starts new software execution after download is complete. The noRun option does not start …
1.3.6.1.4.1.52.259.10.3.1.5Scalarelh100Restartread-writemandatory
1.3.6.1.4.1.52.259.10.3.2NodecabletronELH100BasicCapability
1.3.6.1.4.1.52.259.10.3.2.1NodecabletronELH100StackInfo
1.3.6.1.4.1.52.259.10.3.2.1.1ScalarstackInusedIPread-onlymandatoryThe IP address which is in used in the Dual-Speed Hub system.
1.3.6.1.4.1.52.259.10.3.2.1.2ScalarstackInusedNetMaskread-onlymandatoryThe subnet mask which is in used in the Dual-Speed Hub system.
1.3.6.1.4.1.52.259.10.3.2.1.3ScalarstackInusedGatewayread-onlymandatoryThe prefered gateway used to send traps.
1.3.6.1.4.1.52.259.10.3.2.1.4ScalarstackBootpIPread-onlymandatoryThe IP address of the BOOTP server that last responded. If no BOOP server has responded, then this object will be '0.0.0.0'.
1.3.6.1.4.1.52.259.10.3.2.1.5ScalarstackTemporalIPread-writemandatoryUsed to change the IP address of the Dual-Speed Hub system.
1.3.6.1.4.1.52.259.10.3.2.1.6ScalarstackTemporalNetMaskread-writemandatoryUsed to change the subnet mask of the Dual-Speed Hub system.
1.3.6.1.4.1.52.259.10.3.2.1.7ScalarstackTemporalGatewayread-writemandatoryUsed to change the prefered gateway to send traps.
1.3.6.1.4.1.52.259.10.3.2.1.8ScalarstackBootpEnableread-writemandatoryThis object allows the users to enable/disable generation of BOOTP requests.
1.3.6.1.4.1.52.259.10.3.2.1.9ScalaripInformationResetread-writemandatorySetting the stackIP, stackNetMask,stackGateway, and stackBootUpIP will not make these parameters take effect immediately. They will take effect when ipInformat…
1.3.6.1.4.1.52.259.10.3.2.1.10ScalarstackHealthMonitorread-onlymandatory< FOR cabletronELH100 Dual-Speed Hub DEFINITION : > There are two kinds of hub : 12 ports need (1+ 12 + 1 + 1 + 1 + 1 +1 +1 +1) 20 bytes and 24 ports need (1+ …
1.3.6.1.4.1.52.259.10.3.2.2NodecabletronELH100AgentInfo
1.3.6.1.4.1.52.259.10.3.2.2.1ScalarnicAttachSegmentread-writemandatoryThe ifIndex of the segment to which the agent's Ethernet NIC (Network Interface Controller) is connected. ifIndex 1 is the 100Mbps NIC; ifIndex 2 is the 10Mbps…
1.3.6.1.4.1.52.259.10.3.2.2.2TableserialNumberTablenot-accessiblemandatoryThis table defines the unit serial numbers tracked by the agent. A maximum of 6 serial numbers are tracked.
1.3.6.1.4.1.52.259.10.3.2.2.2.1RowserialNumberEntrynot-accessiblemandatory
1.3.6.1.4.1.52.259.10.3.2.2.2.1.1ColumnsNIndexread-onlymandatoryThe index of the serial number being referenced. Indexes are always sequential, starting with 1.
1.3.6.1.4.1.52.259.10.3.2.2.2.1.2ColumnserialNumberread-onlymandatoryThe serial number. Every ELH100 unit has a unique serial number.
1.3.6.1.4.1.52.259.10.3.2.2.2.1.3ColumnsNCurrentUnitIDread-onlymandatoryThe current unit ID of the unit with this serial number. If the unit with this serial number is not currently in the stack, this object's value is 255. If this…
1.3.6.1.4.1.52.259.10.3.2.2.3ScalartelnetMaxSessionsread-writemandatoryThe maximum number of Telnet sessions that may be active at one time. The factory setting is 2.
1.3.6.1.4.1.52.259.10.3.2.2.4ScalartelnetAutoLogoutEnableread-writemandatorySetting this object to enabled(1) causes the agent to automatically close Telnet sessions when no activity has occurred for telnetAutoLogoutTimeout minutes. Se…
1.3.6.1.4.1.52.259.10.3.2.2.5ScalartelnetAutoLogoutTimeoutread-writemandatoryThe number of minutes of inactivity after which the agent may automatically close a Telnet session. Telnet auto-logout is active only when telnetAutoLogoutEnab…
1.3.6.1.4.1.52.259.10.3.2.2.6ScalarvT100RefreshIntervalread-writemandatoryThe interval for automatic statistics refresh for VT100 screens. The factory setting is seconds30(30).
1.3.6.1.4.1.52.259.10.3.2.3NodecabletronELH100gGroupInfo
1.3.6.1.4.1.52.259.10.3.2.3.1TablegroupTablenot-accessiblemandatoryThis table defines basic configuration information for each unit in the stack.
1.3.6.1.4.1.52.259.10.3.2.3.1.1RowgroupEntrynot-accessiblemandatory
1.3.6.1.4.1.52.259.10.3.2.3.1.1.1ColumngroupIDread-onlymandatoryThe group ID of the group being referenced. Groups are numbered in top-down order, with the top group being group 1. Attempts to reference nonexistent groups a…
1.3.6.1.4.1.52.259.10.3.2.3.1.1.2ColumngroupTyperead-onlymandatoryThe type of group.
1.3.6.1.4.1.52.259.10.3.2.3.1.1.3ColumngroupCounterResetread-writemandatorySetting this object to reset(2) causes the agent to reset all RFC1757 and RFC2108 counters for all ports on this group. This object always returns noReset(1) w…
1.3.6.1.4.1.52.259.10.3.2.3.1.1.4ColumnmgmtModuleStatusread-onlymandatoryThe status of this group's management module. Only one management module in a stack is allowed to act as the active agent. A value of notPresent(1) indicates t…
1.3.6.1.4.1.52.259.10.3.2.3.1.1.5ColumnmgmtModuleDatabaseVersionread-onlymandatoryThe configuration database version number of this managing agent. If a management module is not present, this object's value is a zero-length string. Each mana…
1.3.6.1.4.1.52.259.10.3.2.3.1.1.6ColumnswitchModuleTyperead-onlymandatoryThe type of the switch module.
1.3.6.1.4.1.52.259.10.3.2.3.1.1.7ColumnswitchModuleActiveread-onlymandatoryIndicates whether or not a switch module is active. In order to avoid network loops, the switch hardware allows only one switch to bridge the stack's common 10…
1.3.6.1.4.1.52.259.10.3.2.3.2TablebackplaneTablenot-accessiblemandatoryThis table provides backplane isolation/connection status for each unit's 100Mbps and 10Mbps segments.
1.3.6.1.4.1.52.259.10.3.2.3.2.1RowbackplaneEntrynot-accessiblemandatory
1.3.6.1.4.1.52.259.10.3.2.3.2.1.1ColumnbackplaneGroupIDread-onlymandatoryThe group ID of the segment being referenced. Groups are numbered in top-down order, with the top group being group 1. Attempts to reference nonexistent groups…
1.3.6.1.4.1.52.259.10.3.2.3.2.1.2ColumnbackplaneSegmentIDread-onlymandatoryThe segment ID of the segment being referenced.
1.3.6.1.4.1.52.259.10.3.2.3.2.1.3ColumnbackplaneIsolatedread-writemandatoryThe status of the segment's connection to the backplane bus. The factory setting is attached(2).
1.3.6.1.4.1.52.259.10.3.2.4NodecabletronELH100PortInfo
1.3.6.1.4.1.52.259.10.3.2.4.1TableportTablenot-accessiblemandatoryThis table defines basic configuration information for each repeater port in the stack.
1.3.6.1.4.1.52.259.10.3.2.4.1.1RowportEntrynot-accessiblemandatory
1.3.6.1.4.1.52.259.10.3.2.4.1.1.1ColumnportGroupIDread-onlymandatoryThe group ID of the repeater port being referenced. Groups are numbered in top-down order, with the top group being group 1. Attempts to reference nonexistent …
1.3.6.1.4.1.52.259.10.3.2.4.1.1.2ColumnportIDread-onlymandatoryThe port ID of the repeater port being referenced.
1.3.6.1.4.1.52.259.10.3.2.4.1.1.3ColumnportLinkSpeedread-onlymandatoryThe speed at which the port is currently operating. If there is no link on the port, this object returns noLink(1).
1.3.6.1.4.1.52.259.10.3.2.4.1.1.4ColumnportSpeedConfigread-writemandatorySelects the speed at which the port operates. The factory setting is autoNegotiate(1).
1.3.6.1.4.1.52.259.10.3.3NodecabletronELH100PerfMonCapability
1.3.6.1.4.1.52.259.10.3.3.1NodecabletronELH100PerfMonAgentInfo
1.3.6.1.4.1.52.259.10.3.3.1.1ScalarperfMonAgentCRCErrorsread-onlymandatoryThe number of valid-length packets with CRC errors received on the agent's MAC port.
1.3.6.1.4.1.52.259.10.3.3.1.2ScalarperfMonAgentAlignmentErrorsread-onlymandatoryThe number of valid-length packets with alignment errors received on the agent's MAC port.
1.3.6.1.4.1.52.259.10.3.3.1.3ScalarperfMonAgentCollisionsread-onlymandatoryThe number of collisions detected on the agent's MAC port.
1.3.6.1.4.1.52.259.10.3.3.1.4ScalarperfMonAgentTotalPortIsolatesread-onlymandatoryThe number of times the agent's MAC port became isolated. Port isolation occurs only during 100Mbps operation.
1.3.6.1.4.1.52.259.10.3.3.1.5ScalarperfMonAgentSymbolErrorsread-onlymandatoryThe number of packets with symbol errors received on the agent's MAC port. Symbol errors occur only during 100Mbps operation.
1.3.6.1.4.1.52.259.10.3.4NodecabletronELH100SwitchCapability
1.3.6.1.4.1.52.259.10.3.4.1NodecabletronELH100SwitchInfo
1.3.6.1.4.1.52.259.10.3.4.1.1TableswitchPortTablenot-accessiblemandatoryThis table provides configuration information about each port on each switch module in the stack.
1.3.6.1.4.1.52.259.10.3.4.1.1.1RowswitchPortEntrynot-accessiblemandatory
1.3.6.1.4.1.52.259.10.3.4.1.1.1.1ColumnswitchPortGroupIDread-onlymandatoryThe group ID of the switch module port being referenced. Groups are numbered in top-down order, with the top group being group 1. If a switch module is not ins…
1.3.6.1.4.1.52.259.10.3.4.1.1.1.2ColumnswitchPortIDread-onlymandatoryThe port ID of the switch module port being referenced. Port 1 is always the internal 100Mbps port. Port 2 is always the internal 10Mbps port; note that this p…
1.3.6.1.4.1.52.259.10.3.4.1.1.1.3ColumnswitchPortAdminStatusread-writemandatoryThe administrative status of the port. Setting this object to enabled(1) enables the port. Setting this object to disabled(2) disables the port. On media modul…
1.3.6.1.4.1.52.259.10.3.4.1.1.1.4ColumnswitchPortSpeedread-onlymandatoryThe speed at which the switch port is currently operating. If the port is inactive (port 2 on media modules and port 3 on internal switch modules), noLink(1) i…
1.3.6.1.4.1.52.259.10.3.4.1.1.1.5ColumnswitchPortDuplexread-onlymandatoryThe duplex mode in which the switch port is currently operating. If the port is inactive (port 2 on media modules and port 3 on internal switch modules), notAp…
1.3.6.1.4.1.52.259.10.3.4.1.1.1.6ColumnswitchPortLinkread-onlymandatoryIndicates if link is detected on the port. If the port is inactive (port 2 on media modules and port 3 on internal switch modules), noLink(2) is returned.
1.3.6.1.4.1.52.259.10.3.4.2NodecabletronELH100SwitchStatsInfo
1.3.6.1.4.1.52.259.10.3.4.2.1TableswitchPortStatsTablenot-accessiblemandatoryThis table provides statistics on each port on each switch module in the stack. Note that statistics for the external port on media and switch/media modules ar…
1.3.6.1.4.1.52.259.10.3.4.2.1.1RowswitchPortStatsEntrynot-accessiblemandatory
1.3.6.1.4.1.52.259.10.3.4.2.1.1.1ColumnswitchPortStatsGroupIDread-onlymandatoryThe group ID of the switch module port being referenced. If the group is not present, or if there is no switch module installed in the group, GetRequests and S…
1.3.6.1.4.1.52.259.10.3.4.2.1.1.2ColumnswitchPortStatsIDread-onlymandatoryThe port ID of the switch module port being referenced. Port 1 is always the internal 100Mbps port. Port 2 is always the internal 10Mbps port. Port 3 is always…
1.3.6.1.4.1.52.259.10.3.4.2.1.1.3ColumnswitchPortReadableFramesread-onlymandatoryThe number of valid frames received by the port.
1.3.6.1.4.1.52.259.10.3.4.2.1.1.4ColumnswitchPortReadableOctetsread-onlymandatoryThe number of octets (bytes) in all valid frames received by the port.
1.3.6.1.4.1.52.259.10.3.4.2.1.1.5ColumnswitchPortFCSErrorsread-onlymandatoryThe number of valid-length frames received by the port that had FCS (frame check sequence) errors.
1.3.6.1.4.1.52.259.10.3.4.2.1.1.6ColumnswitchPortAlignmentErrorsread-onlymandatoryThe number of valid-length frames received by the port that had alignment errors.
1.3.6.1.4.1.52.259.10.3.4.2.1.1.7ColumnswitchPortFramesTooLongread-onlymandatoryThe number of frames received by the port that were longer than 1518 bytes.
1.3.6.1.4.1.52.259.10.3.4.2.1.1.8ColumnswitchPortShortEventsread-onlymandatoryThe number of frames received by the port that were shorter than 82 bits.
1.3.6.1.4.1.52.259.10.3.4.2.1.1.9ColumnswitchPortRuntsread-onlymandatoryThe number of frames received by the port that were longer than 82 bits but shorter than 512 bits (64 bytes).
1.3.6.1.4.1.52.259.10.3.4.2.1.1.10ColumnswitchPortCollisionsread-onlymandatoryThe number of collisions detected on the port.
1.3.6.1.4.1.52.259.10.3.4.2.1.1.11ColumnswitchPortLateEventsread-onlymandatoryThe number of collisions detected on the port that occurred later than 512 bit-times into the transmission of a packet.
1.3.6.1.4.1.52.259.10.3.4.2.1.1.12ColumnswitchPortVeryLongEventsread-onlymandatoryThe number of times any activity continued for more than 4 to 7.5 milliseconds.
1.3.6.1.4.1.52.259.10.3.4.2.1.1.13ColumnswitchPortDataRateMismatchesread-onlymandatoryThe number of times the incoming data rate mismatched the local clock source enough to cause a FIFO overflow or underflow.
1.3.6.1.4.1.52.259.10.3.4.2.1.1.14ColumnswitchPortAutoPartitionsread-onlymandatoryThe number of times this port was auto-partitioned by the hardware. In 100Mbps mode, a port auto-partitions when it detects more than 60 consecutive collisions…
1.3.6.1.4.1.52.259.10.3.4.2.1.1.15ColumnswitchPortBroadcastPacketsread-onlymandatoryThe number of good broadcast frames received by the port.
1.3.6.1.4.1.52.259.10.3.4.2.1.1.16ColumnswitchPortMulticastPacketsread-onlymandatoryThe number of good multicast (not broadcast) frames received by the port.
1.3.6.1.4.1.52.259.10.3.4.2.1.1.17ColumnswitchPortIsolatesread-onlymandatoryThe number of times this port was auto-isolated by the hardware. This occurs only during 100Mbps operation. A port auto-isolates when it transmits more than 2 …
1.3.6.1.4.1.52.259.10.3.5NodecabletronELH100BackupCapability
1.3.6.1.4.1.52.259.10.3.5.1NodecabletronELH100BackupInfo
1.3.6.1.4.1.52.259.10.3.5.1.1TablebackupPortTablenot-accessiblemandatoryThis table allows configuration of backup port pairs.
1.3.6.1.4.1.52.259.10.3.5.1.1.1RowbackupPortEntrynot-accessiblemandatory
1.3.6.1.4.1.52.259.10.3.5.1.1.1.1ColumnbackupIndexread-onlymandatoryThe index of the Backup table entry being referenced. Indexes may be nonconsecutive.
1.3.6.1.4.1.52.259.10.3.5.1.1.1.2ColumnbackupPriPortGroupread-writemandatoryGroup ID of the primary port. Attempts to set this object to a nonexistent group are rejected with an error-status of badValue(3). If this object belongs to an…
1.3.6.1.4.1.52.259.10.3.5.1.1.1.3ColumnbackupPriPortPortread-writemandatoryPort number of the primary port. Attempts to set this object to a nonexistent port are rejected with an error-status of badValue(3). If this object belongs to …
1.3.6.1.4.1.52.259.10.3.5.1.1.1.4ColumnbackupSecPortGroupread-writemandatoryGroup ID of the secondary port. The secondary port may be on any group in the stack. Attempts to set this object to a nonexistent unit are rejected with an err…
1.3.6.1.4.1.52.259.10.3.5.1.1.1.5ColumnbackupSecPortPortread-writemandatoryPort number of the secondary port. Attempts to set this object to a nonexistent port are rejected with an error-status of badValue(3). If this object belongs t…
1.3.6.1.4.1.52.259.10.3.5.1.1.1.6ColumnbackupPortActionread-writemandatoryThe status of backup port monitoring for this port pair. Setting this object to active(2) enables the primary port, disables the secondary port, and activates …
1.3.6.1.4.1.52.259.10.3.6NodecabletronELH100SecurityCapability
1.3.6.1.4.1.52.259.10.3.6.1NodecabletronELH100SecurityInfo
1.3.6.1.4.1.52.259.10.3.6.1.1TablesecurityTablenot-accessiblemandatoryThis table allows configuration of port-level intrusion detection.
1.3.6.1.4.1.52.259.10.3.6.1.1.1RowsecurityEntrynot-accessiblemandatory
1.3.6.1.4.1.52.259.10.3.6.1.1.1.1ColumnsecurityGroupIDread-onlymandatoryThe group ID of the port being referenced. Groups are numbered in top-down order, with the top group being group 1. Attempts to reference nonexistent units are…
1.3.6.1.4.1.52.259.10.3.6.1.1.1.2ColumnsecurityPortIDread-onlymandatoryThe port ID of the port being referenced. Attempts to reference nonexistent ports are rejected with an error-status of noSuchName(2).
1.3.6.1.4.1.52.259.10.3.6.1.1.1.3ColumnsecurityAddrread-writemandatoryThe authorized MAC address for this port. This address may be configured through auto-learning if securityAutoLearnAction is set to active(2). Otherwise, the a…
1.3.6.1.4.1.52.259.10.3.6.1.1.1.4ColumnsecurityAutoLearnActionread-writemandatorySelects the auto-learning function for the port. Setting this object to inactive(1) disables auto-learning; the user must set securityAddr in order to specify …
1.3.6.1.4.1.52.259.10.3.6.1.1.1.5ColumnsecurityEnableread-writemandatorySetting this object to warningAndDisable(2) enables intrusion detection on the port. When an intruder is detected, a RFC2108 rptrInfoHealth trap is transmitted…