ELTEK_DISTRIBUTED_PLANT-MIB

178 objects
No module-level DESCRIPTION found.
Imported Objects
ELTEK-COMMON-MIBeltek
SNMPv2-CONFNOTIFICATION-GROUP
SNMPv2-SMIenterprises Integer32 mib-2 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
SNMPv2-TCDisplayString
OIDNameAccessStatusDescription
1.3.6.1.4.1.12148.8NodeeltekDistributedPlant
1.3.6.1.4.1.12148.8.1NodecontrolSystem
1.3.6.1.4.1.12148.8.1.1NodesystemTime
1.3.6.1.4.1.12148.8.1.1.1ScalarsystemTimeTimeread-onlycurrentThe system date and time. Used for event timestamps and logging
1.3.6.1.4.1.12148.8.1.2ScalarsystemInfoRefreshread-writecurrentThis object will re-initialize the agent, updating MIB data values.
1.3.6.1.4.1.12148.8.1.3ScalarsystemTrapRepeatRateread-writecurrentThis object sets the repeat rate of any active traps, in seconds. Entering 0 (zero) will prevent repeating traps - one trap only will be sent per alarm event.
1.3.6.1.4.1.12148.8.1.4ScalarsystemSendOffTrapread-writecurrentA separate off-trap will be issued when an alarm condition goes off, if this flag is set to 1. Entering 0 (zero) will prevent OFF traps from being transmitted.
1.3.6.1.4.1.12148.8.1.5ScalarsystemNumOfControlUnitsread-onlycurrentThe number of expected system controllers (smartpacks, smartnodes stc.) in a distributed system
1.3.6.1.4.1.12148.8.1.6ScalarsystemControlUnitIndexaccessible-for-notifycurrentIndex used for navigating int the table of 1 to 8 system controller input groups
1.3.6.1.4.1.12148.8.1.7TablesystemControlUnitTablenot-accessiblecurrent
1.3.6.1.4.1.12148.8.1.7.1RowsystemControlUnitEntrynot-accessiblecurrent
1.3.6.1.4.1.12148.8.1.7.1.1ColumninputControlUnitIDread-onlycurrent
1.3.6.1.4.1.12148.8.1.7.1.2ColumninputUserConfigurable1read-onlycurrentGeneric alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the …
1.3.6.1.4.1.12148.8.1.7.1.3ColumninputUserConfigurable2read-onlycurrentGeneric alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the …
1.3.6.1.4.1.12148.8.1.7.1.4ColumninputUserConfigurable3read-onlycurrentGeneric alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the …
1.3.6.1.4.1.12148.8.1.7.1.5ColumninputUserConfigurable4read-onlycurrentGeneric alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the …
1.3.6.1.4.1.12148.8.1.7.1.6ColumninputUserConfigurable5read-onlycurrentGeneric alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the …
1.3.6.1.4.1.12148.8.1.7.1.7ColumninputUserConfigurable6read-onlycurrentGeneric alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the …
1.3.6.1.4.1.12148.8.1.7.1.8ColumninputUserConfigurable7read-onlycurrentGeneric alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the …
1.3.6.1.4.1.12148.8.1.7.1.9ColumninputUserConfigurable8read-onlycurrentGeneric alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the …
1.3.6.1.4.1.12148.8.1.7.1.10ColumninputUserConfigurable9read-onlycurrentGeneric alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the …
1.3.6.1.4.1.12148.8.1.7.1.11ColumninputUserConfigurable10read-onlycurrentGeneric alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the …
1.3.6.1.4.1.12148.8.1.8ScalarsystemLinkStatusread-onlycurrentA flag showing the status of the serial port used between the Webpower adapter and the Control system. If this flag shows status linkdown, the propable cause i…
1.3.6.1.4.1.12148.8.1.9ScalarsystemInitiateEEPROMread-writedeprecatedpushbutton function that initiates a forced write of baudrate of 38400bps for the serial port. It also writes default data to the eeprom. This function is used…
1.3.6.1.4.1.12148.8.2NodedcSystem
1.3.6.1.4.1.12148.8.2.1NodedcPlant
1.3.6.1.4.1.12148.8.2.1.3NodesystemSiteInfo
1.3.6.1.4.1.12148.8.2.1.3.1ScalarsystemSiteInfoCustomerread-onlycurrentThe Customer name (as stored in the Smartpack Control Unit)
1.3.6.1.4.1.12148.8.2.1.3.2ScalarsystemSiteInfoLocationread-onlycurrentThe system/site Location details (as stored in the Smartpack Control Unit).
1.3.6.1.4.1.12148.8.2.1.3.3ScalarsystemSiteInfoMessage1read-onlycurrentThe system/site Info Message record #1 (as stored in the Smartpack Control Unit). 31 Bytes.
1.3.6.1.4.1.12148.8.2.1.3.4ScalarsystemSiteInfoMessage2read-onlycurrentThe system/site Info Message record #2 (as stored in the Smartpack Control Unit). 31 Bytes.
1.3.6.1.4.1.12148.8.2.1.3.5ScalarsystemSiteInfoInstalledDateread-onlycurrentThe system's Installed Date text string (as stored in the Smartpack Control Unit) 16bytes.
1.3.6.1.4.1.12148.8.2.1.3.6ScalarsystemSiteInfoControllerTyperead-onlycurrentThe system Controller Module currently connected. AL175/MCU=0; AEON Gold=1; AL6000=2; Smartpack=3
1.3.6.1.4.1.12148.8.2.1.3.7ScalarsystemSiteInfoSystemSeriaNumread-onlycurrentThe serial number for the complete system
1.3.6.1.4.1.12148.8.2.1.3.8ScalarsystemSiteInfoControllerSeriaNumread-onlycurrentThe serial number for the system controller
1.3.6.1.4.1.12148.8.2.1.4ScalarsystemNominalVoltageread-onlycurrentThe nominal voltage rating. 12V/24V/48V/60V systems 0=48V 1=24V 2=12V 3=26V 4=60V
1.3.6.1.4.1.12148.8.2.2ScalarsystemOperationalStatusread-onlycurrentA summary status showing if the system is testing, boosting, floating etc. 0=Float, voltage regulated 1=Float, temperature comp. regulated; 2=equalize 3=batter…
1.3.6.1.4.1.12148.8.3Nodebattery
1.3.6.1.4.1.12148.8.3.1ScalarbatteryNameread-onlycurrentA descriptive name of the battery installed in the system
1.3.6.1.4.1.12148.8.3.2ScalarbatteryVoltageread-onlycurrentThe measured battery voltage.
1.3.6.1.4.1.12148.8.3.3ScalarbatteryCurrentread-onlycurrentThe measured battery current.
1.3.6.1.4.1.12148.8.3.4ScalarbatteryTempread-onlycurrentThe battery temperature
1.3.6.1.4.1.12148.8.3.5ScalarbatteryBreakerStatusread-onlycurrentThe state of the battery fuse/breaker can be either closed(0) or open(1)
1.3.6.1.4.1.12148.8.3.6ScalarbatteryChargeCurrentLimitCtrlread-writecurrentControl field for the battery charge limitation feature; 0=inactive, 1=active.
1.3.6.1.4.1.12148.8.3.7ScalarbatteryChargeCurrentLimitValueread-writecurrentBattery charging current limit value
1.3.6.1.4.1.12148.8.3.8ScalarbatteryTempCompEnableread-writecurrentEnable (0) or Disable (1) Battery Temperature Compensated output regulation mode
1.3.6.1.4.1.12148.8.3.9ScalarbatteryFloatVoltConfigread-writecurrentThe Voltage at which the DC System float charges.
1.3.6.1.4.1.12148.8.3.10ScalarbatteryEqualizeVoltConfigread-writecurrentThe Voltage at which the DC System boost charges the batteries.
1.3.6.1.4.1.12148.8.3.11ScalarbatteryHighMajorAlarmVoltageConfigread-writecurrentThe High Battery Voltage alarm limit set voltage
1.3.6.1.4.1.12148.8.3.12ScalarbatteryHighMinorAlarmVoltageConfigread-writecurrentThe High Battery Voltage alarm limit set voltage
1.3.6.1.4.1.12148.8.3.13ScalarbatteryLowMajorAlarmVoltageConfigread-writecurrentThe Low Battery Voltage Alarm limit set voltage
1.3.6.1.4.1.12148.8.3.14ScalarbatteryLowMinorAlarmVoltageConfigread-writecurrentThe Very Low Battery Voltage Alarm limit set voltage
1.3.6.1.4.1.12148.8.3.15ScalarbatteryStartManualTestread-writecurrentThis pushbutton will start a manual battery test if otherwise the system allows it.
1.3.6.1.4.1.12148.8.3.16ScalarbatteryStartManualBoostread-writecurrentThis pushbutton will start a manual battery boost if otherwise the system allows it.
1.3.6.1.4.1.12148.8.3.17NodebatteryLVD
1.3.6.1.4.1.12148.8.3.17.1ScalarbatteryLVDStatusread-onlycurrentContactor is closed(0) or open(1)
1.3.6.1.4.1.12148.8.3.17.2ScalarbatteryLVDDisconnectVoltageread-writecurrentThe Contactor Disconnect Voltage
1.3.6.1.4.1.12148.8.3.17.3ScalarbatteryLVDConnectVoltageread-writecurrentThe Contactor Reconnect Voltage
1.3.6.1.4.1.12148.8.3.18ScalarbatteryBanksNumofBanksread-onlycurrent
1.3.6.1.4.1.12148.8.3.19NodebatteryBanks
1.3.6.1.4.1.12148.8.3.19.1ScalarbatterySymmetryDeltaLimitVoltageread-writecurrentThe allowable deviation of the midpoint battery voltage from the theoretical. Exceeding this value in either direction (+/-) causes an alarm state
1.3.6.1.4.1.12148.8.3.19.2ScalarbatteryBanksIndexaccessible-for-notifycurrentIndex used for navigating int the table of 1 to 8 batterybank symmetry groups
1.3.6.1.4.1.12148.8.3.19.3TablebatteryBanksTablenot-accessiblecurrentA table of up to 8 battery banks. Each bank may have up to 8 symmetry or midpoint measuments
1.3.6.1.4.1.12148.8.3.19.3.1RowbatteryBanksEntrynot-accessiblecurrenta distributed control system may contain up to 8 battery banks.
1.3.6.1.4.1.12148.8.3.19.3.1.1ColumnbatteryBankIDread-onlycurrent
1.3.6.1.4.1.12148.8.3.19.3.1.2ColumnbatteryBanksSymmetry1enableread-writecurrentWhen set to 'on' the the symmetry input is activated. when turned off, measuments for this input is turned off and the correcponding value will read 0 volts an…
1.3.6.1.4.1.12148.8.3.19.3.1.3ColumnbatteryBanksSymmetry1statusread-onlycurrentStatus (0=Normal; 1=Alarm) of the Battery Monitor channel which corresponds to the batteryMidpointIndex value
1.3.6.1.4.1.12148.8.3.19.3.1.4ColumnbatteryBanksSymmetry1deltaVoltageread-onlycurrentThe measured battery voltage deviation from midpoint of the Battery Monitor channel which corresponds to the batteryMidpointIndex value.
1.3.6.1.4.1.12148.8.3.19.3.1.5ColumnbatteryBanksSymmetry2enableread-writecurrentWhen set to 'on' the the symmetry input is activated. when turned off, measuments for this input is turned off and the correcponding value will read 0 volts an…
1.3.6.1.4.1.12148.8.3.19.3.1.6ColumnbatteryBanksSymmetry2statusread-onlycurrentStatus (0=Normal; 1=Alarm) of the Battery Monitor channel which corresponds to the batteryMidpointIndex value
1.3.6.1.4.1.12148.8.3.19.3.1.7ColumnbatteryBanksSymmetry2deltaVoltageread-onlycurrentThe measured battery voltage deviation from midpoint of the Battery Monitor channel which corresponds to the batteryMidpointIndex value.
1.3.6.1.4.1.12148.8.3.19.3.1.8ColumnbatteryBanksSymmetry3enableread-writecurrentWhen set to 'on' the the symmetry input is activated. when turned off, measuments for this input is turned off and the correcponding value will read 0 volts an…
1.3.6.1.4.1.12148.8.3.19.3.1.9ColumnbatteryBanksSymmetry3statusread-onlycurrentStatus (0=Normal; 1=Alarm) of the Battery Monitor channel which corresponds to the batteryMidpointIndex value
1.3.6.1.4.1.12148.8.3.19.3.1.10ColumnbatteryBanksSymmetry3deltaVoltageread-onlycurrentThe measured battery voltage deviation from midpoint of the Battery Monitor channel which corresponds to the batteryMidpointIndex value.
1.3.6.1.4.1.12148.8.3.19.3.1.11ColumnbatteryBanksSymmetry4enableread-writecurrentWhen set to 'on' the the symmetry input is activated. when turned off, measuments for this input is turned off and the correcponding value will read 0 volts an…
1.3.6.1.4.1.12148.8.3.19.3.1.12ColumnbatteryBanksSymmetry4statusread-onlycurrentStatus (0=Normal; 1=Alarm) of the Battery Monitor channel which corresponds to the batteryMidpointIndex value
1.3.6.1.4.1.12148.8.3.19.3.1.13ColumnbatteryBanksSymmetry4deltaVoltageread-onlycurrentThe measured battery voltage deviation from midpoint of the Battery Monitor channel which corresponds to the batteryMidpointIndex value.
1.3.6.1.4.1.12148.8.3.19.3.1.14ColumnbatteryBanksSymmetry5enableread-writecurrentWhen set to 'on' the the symmetry input is activated. when turned off, measuments for this input is turned off and the correcponding value will read 0 volts an…
1.3.6.1.4.1.12148.8.3.19.3.1.15ColumnbatteryBanksSymmetry5statusread-onlycurrentStatus (0=Normal; 1=Alarm) of the Battery Monitor channel which corresponds to the batteryMidpointIndex value
1.3.6.1.4.1.12148.8.3.19.3.1.16ColumnbatteryBanksSymmetry5deltaVoltageread-onlycurrentThe measured battery voltage deviation from midpoint of the Battery Monitor channel which corresponds to the batteryMidpointIndex value.
1.3.6.1.4.1.12148.8.3.19.3.1.17ColumnbatteryBanksSymmetry6enableread-writecurrentWhen set to 'on' the the symmetry input is activated. when turned off, measuments for this input is turned off and the correcponding value will read 0 volts an…
1.3.6.1.4.1.12148.8.3.19.3.1.18ColumnbatteryBanksSymmetry6statusread-onlycurrentStatus (0=Normal; 1=Alarm) of the Battery Monitor channel which corresponds to the batteryMidpointIndex value
1.3.6.1.4.1.12148.8.3.19.3.1.19ColumnbatteryBanksSymmetry6deltaVoltageread-onlycurrentThe measured battery voltage deviation from midpoint of the Battery Monitor channel which corresponds to the batteryMidpointIndex value.
1.3.6.1.4.1.12148.8.3.19.3.1.20ColumnbatteryBanksSymmetry7enableread-writecurrentWhen set to 'on' the the symmetry input is activated. when turned off, measuments for this input is turned off and the correcponding value will read 0 volts an…
1.3.6.1.4.1.12148.8.3.19.3.1.21ColumnbatteryBanksSymmetry7statusread-onlycurrentStatus (0=Normal; 1=Alarm) of the Battery Monitor channel which corresponds to the batteryMidpointIndex value
1.3.6.1.4.1.12148.8.3.19.3.1.22ColumnbatteryBanksSymmetry7deltaVoltageread-onlycurrentThe measured battery voltage deviation from midpoint of the Battery Monitor channel which corresponds to the batteryMidpointIndex value.
1.3.6.1.4.1.12148.8.3.19.3.1.23ColumnbatteryBanksSymmetry8enableread-writecurrentWhen set to 'on' the the symmetry input is activated. when turned off, measuments for this input is turned off and the correcponding value will read 0 volts an…
1.3.6.1.4.1.12148.8.3.19.3.1.24ColumnbatteryBanksSymmetry8statusread-onlycurrentStatus (0=Normal; 1=Alarm) of the Battery Monitor channel which corresponds to the batteryMidpointIndex value
1.3.6.1.4.1.12148.8.3.19.3.1.25ColumnbatteryBanksSymmetry8deltaVoltageread-onlycurrentThe measured battery voltage deviation from midpoint of the Battery Monitor channel which corresponds to the batteryMidpointIndex value.
1.3.6.1.4.1.12148.8.4NodeloadDistribution
1.3.6.1.4.1.12148.8.4.1ScalarloadDistributionCurrentread-onlycurrentThe total load current
1.3.6.1.4.1.12148.8.4.2ScalarloadDistributionBreakerStatusread-onlycurrentThe state of the load fuse/breaker can be either closed(0) or open(1)
1.3.6.1.4.1.12148.8.4.3NodeloadDistributionLVDStatus
1.3.6.1.4.1.12148.8.4.3.1ScalarloadLVD1EnableStatusread-onlycurrentThe status of contactors configuration. 'enabled' means that the contactor is i n use. 'disabled' means that the contactor is disconfigured and not in use.
1.3.6.1.4.1.12148.8.4.3.2ScalarloadLVD1Statusread-onlycurrentThe primary load Contactor is closed(0) or open(1)
1.3.6.1.4.1.12148.8.4.3.3ScalarloadLVD1ConnectVoltageread-writecurrentThe primary loads Contactor Connect Voltage
1.3.6.1.4.1.12148.8.4.3.4ScalarloadLVD1DisconnectVoltageread-writecurrentThe primary load Contactor Disconnect Voltage
1.3.6.1.4.1.12148.8.4.3.5ScalarloadLVD2EnableStatusread-onlycurrentThe status of contactors configuration. 'enabled' means that the contactor is i n use. 'disabled' means that the contactor is disconfigured and not in use.
1.3.6.1.4.1.12148.8.4.3.6ScalarloadLVD2Statusread-onlycurrentThe secondary load Contactor is closed(0) or open(1)
1.3.6.1.4.1.12148.8.4.3.7ScalarloadLVD2ConnectVoltageread-writecurrentThe secondary load Contactor Connect Voltage
1.3.6.1.4.1.12148.8.4.3.8ScalarloadLVD2DisconnectVoltageread-writecurrentThe secondary loads Contactor Disconnect Voltage
1.3.6.1.4.1.12148.8.4.3.9ScalarloadLVD3EnableStatusread-onlycurrentThe status of contactors configuration. 'enabled' means that the contactor is i n use. 'disabled' means that the contactor is disconfigured and not in use.
1.3.6.1.4.1.12148.8.4.3.10ScalarloadLVD3Statusread-onlycurrentThe third critical loads Contactor is closed(0) or open(1)
1.3.6.1.4.1.12148.8.4.3.11ScalarloadLVD3ConnectVoltageread-writecurrentThe third critical load Contactor Connect Voltage
1.3.6.1.4.1.12148.8.4.3.12ScalarloadLVD3DisconnectVoltageread-writecurrentThe third critical loads Contactor Disconnect Voltage
1.3.6.1.4.1.12148.8.5Noderectifier
1.3.6.1.4.1.12148.8.5.1ScalarrectifierInstalledRectifiersread-onlycurrentThe installed number of rectifiers for this DC Power System.
1.3.6.1.4.1.12148.8.5.2ScalarrectifierRectifiersActiveread-onlycurrentThe actual number of active rectifiers in this DC Power System.
1.3.6.1.4.1.12148.8.5.3ScalarrectifierTotalCurrentread-onlycurrentThe DC system's total available current
1.3.6.1.4.1.12148.8.5.4ScalarrectifierUtilizationread-onlycurrentUtilization in % of available rectifier capacity
1.3.6.1.4.1.12148.8.5.5NoderectifierStatus
1.3.6.1.4.1.12148.8.5.5.1ScalarrectifierStatusNoIndexread-writecurrentA starting index for the rectifierStatusTable array
1.3.6.1.4.1.12148.8.5.5.2TablerectifierStatusTablenot-accessiblecurrentA table listing up to sixteen sequential recifiers, starting from the rectifier number specified by rectifierStatusNoIndex
1.3.6.1.4.1.12148.8.5.5.2.1RowrectifierStatusEntrynot-accessiblecurrentA row of rectifier status data corresponding to the rectifierStatusNoIndex value
1.3.6.1.4.1.12148.8.5.5.2.1.1ColumnrectifierStatusIDread-onlycurrentThe rectifier ID number of the rectifier record.
1.3.6.1.4.1.12148.8.5.5.2.1.2ColumnrectifierStatusStatusread-onlycurrentThe operational status of the rectifier record. absent (0), active (1), failed (2), walkin (3), disabledbycommand (4)
1.3.6.1.4.1.12148.8.5.5.2.1.3ColumnrectifierStatusOutputCurrentread-onlycurrentThe rectifier current of the rectifier record.
1.3.6.1.4.1.12148.8.5.5.2.1.4ColumnrectifierStatusOutputVoltageread-onlycurrentThe rectifier voltage of the rectifier record.
1.3.6.1.4.1.12148.8.5.5.2.1.5ColumnrectifierStatusTempread-onlycurrentThe heatsink temperature of the rectifier record.
1.3.6.1.4.1.12148.8.5.5.2.1.6ColumnrectifierStatusTyperead-onlycurrentThe rectifier article number string of the rectifier record.
1.3.6.1.4.1.12148.8.5.5.2.1.7ColumnrectifierStatusSKUread-onlycurrentThe rectifier Stock Keeping Unit number or other user-defined ID of the rectifier record.
1.3.6.1.4.1.12148.8.5.5.2.1.8ColumnrectifierStatusSerialNoread-onlycurrentThe rectifier serial number string of the rectifier record.
1.3.6.1.4.1.12148.8.5.5.2.1.9ColumnrectifierStatusRevisionLevelread-onlycurrentThe rectifier version number string of the rectifier record.
1.3.6.1.4.1.12148.8.6NodeacDistribution
1.3.6.1.4.1.12148.8.6.1ScalaracVoltage1read-onlycurrentThe AC Voltage of phase 1
1.3.6.1.4.1.12148.8.6.2ScalaracVoltage2read-onlycurrentThe AC Voltage of phase 2
1.3.6.1.4.1.12148.8.6.3ScalaracVoltage3read-onlycurrentThe AC Voltage of phase 3
1.3.6.1.4.1.12148.8.7NodealarmGroup
1.3.6.1.4.1.12148.8.7.1NodealarmWellknownAlarms
1.3.6.1.4.1.12148.8.7.1.1ScalaralarmMajorHighBattVoltread-onlycurrentThe Very High Battery Voltage Alarm
1.3.6.1.4.1.12148.8.7.1.2ScalaralarmMinorHighBattVoltread-onlycurrentThe High Battery Voltage alarm
1.3.6.1.4.1.12148.8.7.1.3ScalaralarmMajorLowBattVoltread-onlycurrentThe Very Low Battery Voltage Alarm
1.3.6.1.4.1.12148.8.7.1.4ScalaralarmMinorLowBattVoltread-onlycurrentThe Low Battery Voltage Alarm
1.3.6.1.4.1.12148.8.7.1.5ScalaralarmMajorBatteryHighTempread-onlycurrentTemperature much too high alarm, or temperature compensation circuit / probe failure alarm
1.3.6.1.4.1.12148.8.7.1.6ScalaralarmMinorBatteryHighTempread-onlycurrentTemperature much too high alarm
1.3.6.1.4.1.12148.8.7.1.7ScalaralarmBatteryDisconnectOpenread-onlycurrentThe Battery Disconnect Contactor alarm
1.3.6.1.4.1.12148.8.7.1.8ScalaralarmLVD1openread-onlycurrentThe A Bus (primary loads) Contactor alarm. The contactor dropout voltage has been reached and the contactor will release.
1.3.6.1.4.1.12148.8.7.1.9ScalaralarmLVD2openread-onlycurrentThe B Bus (secondary loads) Contactor alarm. The contactor dropout voltage has been reached and the contactor will release.
1.3.6.1.4.1.12148.8.7.1.10ScalaralarmLVD3openread-onlycurrentThe C Bus (critical loads) Contactor alarm. The contactor dropout voltage has been reached and the contactor will release.
1.3.6.1.4.1.12148.8.7.1.11ScalaralarmACmainsread-onlycurrentThe AC voltage has dropped below critical level, or one or more AC input phases was lost.
1.3.6.1.4.1.12148.8.7.1.12ScalaralarmBatteryBreakerOpenread-onlycurrentBattery string disconnect breaker/fuse alarm
1.3.6.1.4.1.12148.8.7.1.13ScalaralarmDistributionBreakerOpenread-onlycurrentThe Load Distribution breaker/fuse alarm
1.3.6.1.4.1.12148.8.7.1.14ScalaralarmMajorRectifierread-onlycurrentThis is a 'multiple rectifiers have failed' alarm
1.3.6.1.4.1.12148.8.7.1.15ScalaralarmMinorRectifierread-onlycurrentThis is a 'one rectifier has failed' alarm
1.3.6.1.4.1.12148.8.7.1.16ScalaralarmMajorBatteryMidpointread-onlycurrentBattery Symmetry (midpoint) Delta Voltage is badly out of limits alarm
1.3.6.1.4.1.12148.8.7.1.17ScalaralarmMinorBatteryMidpointread-onlycurrentBattery Symmetry (midpoint) Delta Voltage out of limits alarm
1.3.6.1.4.1.12148.8.7.1.18ScalaralarmBatteryLifeEndedread-onlycurrentThe battery capacity has dropped below critical level. A battery test has measured the fully charged capacity to be too low, and thus probably the battery life…
1.3.6.1.4.1.12148.8.7.1.19ScalaralarmBatteryTestmodeEnteredread-onlycurrentThe system has lowered the battery charge voltage in order to discharge the batteries to a predefinend level. When the criteria for stopping the battery testin…
1.3.6.1.4.1.12148.8.7.1.20ScalaralarmBatteryBoostmodeEnteredread-onlycurrentThe system has increased the battery charge voltage in order to equalize the battery cells charging. When the criteria for stopping the battery equalizing is r…
1.3.6.1.4.1.12148.8.8GroupdcSystemTrapscurrentThis branch contains the Alarm Notification Traps, which duplicate the alarmGroup OIDs. Each alarm condition is represented by a Alarm Condition Trap and an as…
1.3.6.1.4.1.12148.8.8.1NotificationalarmMajorHighBattVoltTrapcurrentThe Very High Battery Voltage alarm
1.3.6.1.4.1.12148.8.8.2NotificationalarmMinorHighBattVoltTrapcurrentThe High Battery Voltage alarm
1.3.6.1.4.1.12148.8.8.3NotificationalarmMajorLowBattVoltTrapcurrentThe Very Low Battery Voltage Alarm
1.3.6.1.4.1.12148.8.8.4NotificationalarmMinorLowBattVoltTrapcurrentThe Low Battery Voltage Alarm
1.3.6.1.4.1.12148.8.8.5NotificationalarmMajorBatteryHighTempTrapcurrentHigh Battery temperature alarm or Temperature Compensation circuit / probe failure alarm
1.3.6.1.4.1.12148.8.8.6NotificationalarmMinorBatteryHighTempTrapcurrentHigh Battery temperature alarm
1.3.6.1.4.1.12148.8.8.7NotificationalarmBatteryDisconnectOpenTrapcurrentThe Battery Disconnect Contactor alarm
1.3.6.1.4.1.12148.8.8.8NotificationalarmLVD1openTrapcurrentThe A Bus (primary loads) Contactor is open alarm
1.3.6.1.4.1.12148.8.8.9NotificationalarmLVD2openTrapcurrentThe B Bus (secondary loads) Contactor is open alarm
1.3.6.1.4.1.12148.8.8.10NotificationalarmLVD3openTrapcurrentThe C Bus (critical loads) Contactor alarm. The contactor dropout voltage has been reached and the contactor is released.
1.3.6.1.4.1.12148.8.8.11NotificationalarmACmainsTrapcurrentThe AC voltage has dropped below critical level, or one or more AC input phases was lost.
1.3.6.1.4.1.12148.8.8.12NotificationalarmBatteryBreakerOpenTrapcurrentBattery string disconnect breaker/fuse alarm
1.3.6.1.4.1.12148.8.8.13NotificationalarmDistributionBreakerOpenTrapcurrentThe Load Distribution breaker/fuse alarm
1.3.6.1.4.1.12148.8.8.14NotificationalarmMajorRectifierTrapcurrentThis is a 'multiple rectifiers have failed' alarm
1.3.6.1.4.1.12148.8.8.15NotificationalarmMinorRectifierTrapcurrentThis is a 'one rectifier has failed' alarm
1.3.6.1.4.1.12148.8.8.16NotificationalarmMajorBatteryMidpointTrapcurrentBattery Symmetry (midpoint) Delta Voltage out of 'major fault' limits alarm
1.3.6.1.4.1.12148.8.8.17NotificationalarmMinorBatteryMidpointTrapcurrentBattery Symmetry (midpoint) Delta Voltage out of limits alarm
1.3.6.1.4.1.12148.8.8.18NotificationalarmBatteryLifeEndedTrapcurrentThe battery capacity has dropped below critical level. A battery test has measured the fully charged capacity to be too low, and thus probably the battery life…
1.3.6.1.4.1.12148.8.8.19NotificationalarmBatteryTestmodeEnteredTrapcurrentThe system has lowered the battery charge voltage in order to discharge the batteries to a predefinend level. When the criteria for stopping the battery testin…
1.3.6.1.4.1.12148.8.8.20NotificationalarmBatteryBoostmodeEnteredTrapcurrentThe system has increased the battery charge voltage in order to equalize the battery cells charging. When the criteria for stopping the battery equalizing is r…
1.3.6.1.4.1.12148.8.8.21NotificationalarmController1proginputTrapcurrentGeneric alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the …
1.3.6.1.4.1.12148.8.8.22NotificationalarmController2proginputTrapcurrentGeneric alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the …
1.3.6.1.4.1.12148.8.8.23NotificationalarmController3proginputTrapcurrentGeneric alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the …
1.3.6.1.4.1.12148.8.8.24NotificationalarmController4proginputTrapcurrentGeneric alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the …
1.3.6.1.4.1.12148.8.8.25NotificationalarmController5proginputTrapcurrentGeneric alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the …
1.3.6.1.4.1.12148.8.8.26NotificationalarmController6proginputTrapcurrentGeneric alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the …
1.3.6.1.4.1.12148.8.8.27NotificationalarmController7proginputTrapcurrentGeneric alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the …
1.3.6.1.4.1.12148.8.8.28NotificationalarmController8proginputTrapcurrentGeneric alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the …