MIB Viewer

ENCLOSURE-MIB

33 objects
The MIB module to describe the enclosure.
Imported Objects
DASAN-SMIotherEnterprises
SNMPv2-CONFMODULE-COMPLIANCE OBJECT-GROUP
SNMPv2-SMICounter32 Counter64 Gauge32 Integer32 mib-2 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE TimeTicks
SNMPv2-TCAutonomousType DisplayString PhysAddress RowStatus TestAndIncr TEXTUAL-CONVENTION TimeStamp TruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.6296.6.1IdentityenclosureMIBThe MIB module to describe the enclosure.
1.3.6.1.4.1.6296.6.1.1NodeenclosureEvents
1.3.6.1.4.1.6296.6.1.1.1001NodeenclosureDoorTrapThe Enclosure Door Trap.
1.3.6.1.4.1.6296.6.1.1.1001NotificationenclosureTrapcurrentThe Enclosure Trap.
1.3.6.1.4.1.6296.6.1.2NodeenclosureMIBObjects
1.3.6.1.4.1.6296.6.1.2.1ScalarenDoorAdminStatusread-writecurrentA value that determined whether to use door-sensor or not.
1.3.6.1.4.1.6296.6.1.2.2ScalarenDoorOperStatusread-onlycurrentdisplay that door is open or not.
1.3.6.1.4.1.6296.6.1.2.3ScalarenFireAdminStatusread-writecurrentA value that determined whether to use Fire-sensor or not.
1.3.6.1.4.1.6296.6.1.2.4ScalarenFireOperStatusread-onlycurrentdisplay that fire is occrued or not.
1.3.6.1.4.1.6296.6.1.2.5ScalarenFanAdminStatusread-writecurrentA value that determined whether to use Fan-sensor or not.
1.3.6.1.4.1.6296.6.1.2.6ScalarenFanOperStatusread-onlycurrentdisplay that fan is running or not.
1.3.6.1.4.1.6296.6.1.2.7ScalarenFloodAdminStatusread-writecurrentA value that determined whether to use Flood-sensor or not.
1.3.6.1.4.1.6296.6.1.2.8ScalarenFloodOperStatusread-onlycurrentdisplay that flooding exists or not.
1.3.6.1.4.1.6296.6.1.2.9TableenTemperatureTablenot-accessiblecurrentThe Temperature table of Enclosure.
1.3.6.1.4.1.6296.6.1.2.9.1RowenTemperatureEntrynot-accessiblecurrentAn entry containing management information applicable to enclosure's Temperature.
1.3.6.1.4.1.6296.6.1.2.9.1.1ColumnenTemperatureIndexread-onlycurrentA unique value, greater than zero, for each Temperature sensor.It is recommended that values are assigned contiguously starting from 1.
1.3.6.1.4.1.6296.6.1.2.9.1.2ColumnenTemperatureValueread-onlycurrentA Temerature in the enclosure.
1.3.6.1.4.1.6296.6.1.2.9.1.3ColumnenTemperatureAdminStatusread-writecurrentA value that determined whether to use temperature-sensor or not.
1.3.6.1.4.1.6296.6.1.2.9.1.4ColumnenTemperatureOperStatusread-onlycurrentA status value that display current Operational status.
1.3.6.1.4.1.6296.6.1.2.9.1.5ColumnenTemperatureCeilThresholdread-writecurrentA ceil value of temperature threshold.
1.3.6.1.4.1.6296.6.1.2.9.1.6ColumnenTemperatureFloorThresholdread-writecurrentA floor value of temperature threshold.
1.3.6.1.4.1.6296.6.1.2.10TableenHumidityTablenot-accessiblecurrentThe Humidity table of Enclosure.
1.3.6.1.4.1.6296.6.1.2.10.1RowenHumidityEntrynot-accessiblecurrentAn entry containing management information applicable to a Humidity sensor.
1.3.6.1.4.1.6296.6.1.2.10.1.1ColumnenHumidityIndexread-onlycurrentA unique value, greater than zero, for each Humidity sensor. It is recommended that values are assigned contiguously starting from 1.
1.3.6.1.4.1.6296.6.1.2.10.1.2ColumnenHumidityValueread-onlycurrentA Humidity in the enclosure.
1.3.6.1.4.1.6296.6.1.2.10.1.3ColumnenHumidityAdminStatusread-writecurrentA value that determined whether to use humidity-sensor or not.
1.3.6.1.4.1.6296.6.1.2.10.1.4ColumnenHumidityOperStatusread-onlycurrentA status value that display current Operational status.
1.3.6.1.4.1.6296.6.1.2.10.1.5ColumnenHumidityCeilThresholdread-writecurrentA ceil value of humidity threshold.
1.3.6.1.4.1.6296.6.1.2.10.1.6ColumnenHumidityFloorThresholdread-writecurrentA floor value of humidity threshold.
1.3.6.1.4.1.6296.6.1.2.11TableenEnclosureInfoTablenot-accessiblecurrentThe Information table of Enclosure.
1.3.6.1.4.1.6296.6.1.2.11.1RowenEnclosureInfoEntrynot-accessiblecurrentAn entry containing management information applicable to a enclosure.
1.3.6.1.4.1.6296.6.1.2.11.1.1ColumnenEnclosureInfoIndexread-onlycurrentA unique value, greater than zero, for each Enclosure. It is recommended that values are assigned contiguously starting from 1.
1.3.6.1.4.1.6296.6.1.2.11.1.2ColumnenEnclosureInfoOperStatusread-onlycurrentDisplay enclosure operation status. alive(1) noreply(2) noreply means maybe that there is no enclosure.