MIB Viewer

ENTERASYS-IEEE802DOT11EXT-MIB

49 objects
This mib module defines a portion of the SNMP enterprise MIBs under Enterasys Networks enterprise OID as an extension to the IEEE802Dot11 MIB. This Enterasys Networks Proprietary MIB was designed to be used for read-write access to configuration objects not provided by IEEE802.11 MIB, or any other standard MIB.
OIDNameAccessStatusDescription
1.3.6.1.4.1.5624.1.2.9IdentityetsysDot11ExtMIBThis mib module defines a portion of the SNMP enterprise MIBs under Enterasys Networks enterprise OID as an extension to the IEEE802Dot11 MIB. This Enterasys N…
1.3.6.1.4.1.5624.1.2.9.1NodeetsysDot11ExtObjects
1.3.6.1.4.1.5624.1.2.9.1.1NodeetsysDot11ExtLinkTest
1.3.6.1.4.1.5624.1.2.9.1.1.1TableetsysDot11ExtLinkTestTablenot-accessiblecurrentThis table contains objects to test the link between a requester (entity which sends out the management request message) and a responder (entity which responds…
1.3.6.1.4.1.5624.1.2.9.1.1.1.1RowetsysDot11ExtLinkTestEntrynot-accessiblecurrentAn Entry (conceptual row) in the LinkTest Table. By means of message transmission between requester and responder, the communication quality between the two st…
1.3.6.1.4.1.5624.1.2.9.1.1.1.1.1ColumnetsysDot11ExtLTRemoteStationMACread-writecurrentThe MAC address for the remote station to participate in the Link Test. To initiate a search for a participating station, write the broadcast address (FF-FF-FF…
1.3.6.1.4.1.5624.1.2.9.1.1.1.1.2ColumnetsysDot11ExtLTRemoteStationNameread-onlycurrentThe wireless station name of the remote station participating in the Link Test.
1.3.6.1.4.1.5624.1.2.9.1.1.1.1.3ColumnetsysDot11ExtLTTriggerread-writecurrentWriting a 1 to this variable causes a single Link Test request message to be sent to the remote station.
1.3.6.1.4.1.5624.1.2.9.1.1.1.1.4ColumnetsysDot11ExtLTRemoteContentsread-onlycurrentThe exact byte-by-byte contents of the Link Test packet returned by the remote station.
1.3.6.1.4.1.5624.1.2.9.1.2NodeetsysDot11ExtGeneral
1.3.6.1.4.1.5624.1.2.9.1.2.1TableetsysDot11ExtGeneralTablenot-accessiblecurrentThis table contains all the objects that must be configured on every radio card installed in the Access Point regardless of the operating mode in use.
1.3.6.1.4.1.5624.1.2.9.1.2.1.1RowetsysDot11ExtGeneralEntrynot-accessiblecurrentAn Entry (conceptual row) in the Dot11General Table. This allows for multiple instances of radio cards in the Access Point.
1.3.6.1.4.1.5624.1.2.9.1.2.1.1.1ColumnetsysDot11ExtPCCardTyperead-onlycurrentThe type of PC card inserted in the Access Point.
1.3.6.1.4.1.5624.1.2.9.1.2.1.1.2ColumnetsysDot11ExtPCCardVersionsread-onlycurrentSpecifies the version identifiers for the PC card. This will indicate both the Hardware and the Firmware versions.
1.3.6.1.4.1.5624.1.2.9.1.2.1.1.3ColumnetsysDot11ExtBridgeModeread-writecurrentCURRENT Access Point bridge mode state. In workgroup mode all communications between clients passes through the Access Point. LAN-to-LAN mode is the improved n…
1.3.6.1.4.1.5624.1.2.9.1.2.1.1.4ColumnetsysDot11ExtResetOptionsread-writecurrentnoReset (0) No reset is performed. A 'get' on this object always returns this value. resetRadioCardIfNecessary (1) Some parameters can only be given to the car…
1.3.6.1.4.1.5624.1.2.9.1.2.1.1.5ColumnetsysDot11ExtSystemScaleread-writecurrentSpecifies the CURRENT Access Point density in the Extended Service Set (ESS). This object must be saved across a system reset and/or a power cycle.
1.3.6.1.4.1.5624.1.2.9.1.2.1.1.6ColumnetsysDot11ExtSecureAccessread-writecurrentWhen this mode is set to enabled, the AP will only associate with stations that have the same network name as the AP. When this mode is set to disabled, a stat…
1.3.6.1.4.1.5624.1.2.9.1.2.1.1.7ColumnetsysDot11ExtMulticastTxRateread-writecurrentThis value specifies the Multicast data transmission rate of the AP. It is implemented when cards that operate faster than the 2Mbit 802.11 standard are insert…
1.3.6.1.4.1.5624.1.2.9.1.2.1.1.8ColumnetsysDot11ExtIntraBSSRelayread-writecurrentWhen this mode is enabled the AP entity within the PC Card will relay frames to destined for stations associated with it and will NOT forward them to the bridg…
1.3.6.1.4.1.5624.1.2.9.1.2.1.1.9ColumnetsysDot11ExtStationNameread-writecurrentDURABLE: The wireless station name sent out as part of the beacon messages. Valid only when a DS card is inserted in the Access Point.
1.3.6.1.4.1.5624.1.2.9.1.3NodeetsysDot11ExtBldg
1.3.6.1.4.1.5624.1.2.9.1.3.1TableetsysDot11ExtBldgTablenot-accessiblecurrentThis table contains the objects required to enable the Access Point to operate in Point-to-MultiPoint mode.
1.3.6.1.4.1.5624.1.2.9.1.3.1.1RowetsysDot11ExtBldgEntrynot-accessiblecurrentAn Entry (conceptual row) in the Dot11Bldg Table. A collection of objects containing information for activating and using the Access Point in Point-to-MultiPoi…
1.3.6.1.4.1.5624.1.2.9.1.3.1.1.1ColumnetsysDot11ExtBldgRemoteMAC1read-writecurrentThe MAC address for the remote station participating in a 802.11 Building-to-Building link. This object must be saved across a system reset and/or a power cycl…
1.3.6.1.4.1.5624.1.2.9.1.3.1.1.2ColumnetsysDot11ExtBldgRemoteMAC2read-writecurrentThe MAC address for the remote station participating in a 802.11 Building-to-Building link. This object must be saved across a system reset and/or a power cycl…
1.3.6.1.4.1.5624.1.2.9.1.3.1.1.3ColumnetsysDot11ExtBldgRemoteMAC3read-writecurrentThe MAC address for the remote station participating in a 802.11 Building-to-Building link. This object must be saved across a system reset and/or a power cycl…
1.3.6.1.4.1.5624.1.2.9.1.3.1.1.4ColumnetsysDot11ExtBldgRemoteMAC4read-writecurrentThe MAC address for the remote station participating in a 802.11 Building-to-Building link. This object must be saved across a system reset and/or a power cycl…
1.3.6.1.4.1.5624.1.2.9.1.3.1.1.5ColumnetsysDot11ExtBldgRemoteMAC5read-writecurrentThe MAC address for the remote station participating in a 802.11 Building-to-Building link. This object must be saved across a system reset and/or a power cycl…
1.3.6.1.4.1.5624.1.2.9.1.3.1.1.6ColumnetsysDot11ExtBldgRemoteMAC6read-writecurrentThe MAC address for the remote station participating in a 802.11 Building-to-Building link. This object must be saved across a system reset and/or a power cycl…
1.3.6.1.4.1.5624.1.2.9.1.3.1.1.7ColumnetsysDot11ExtBldgMPActivationKeyread-writecurrentPoint-to-multipoint bridge mode requires an activation key to enable. A valid multipoint activation key must be entered as a string of ACSCII characters transl…
1.3.6.1.4.1.5624.1.2.9.1.4NodeetsysDot11ExtWEP
1.3.6.1.4.1.5624.1.2.9.1.4.1TableetsysDot11ExtWEPDefaultKeysTablenot-accessiblecurrentConceptual table for WEP default keys. This table shall contain the four WEP default secret key values corresponding to the four possible KeyID values. The WEP…
1.3.6.1.4.1.5624.1.2.9.1.4.1.1RowetsysDot11ExtWEPDefaultKeysEntrynot-accessiblecurrentAn Entry (conceptual row) in the WEP Default Keys Table. A collection of objects containing information used to determine if a WEPkey as been defined and if so…
1.3.6.1.4.1.5624.1.2.9.1.4.1.1.1ColumnetsysDot11ExtWEPKeyDefinedread-onlycurrentThe state column used for determining if an encryption key is set (true) or not (false), false is the default value.
1.3.6.1.4.1.5624.1.2.9.1.4.1.1.2ColumnetsysDot11ExtWEPKeyValueread-writecurrentA WEP default secret key value. For 40-bit encryption use 5 printable characters or 10 HEX digits. For 128-bit encryption use 13 printable characters or 26 HEX…
1.3.6.1.4.1.5624.1.2.9.1.4.2TableetsysDot11ExtWEPEnhancedTablenot-accessiblecurrentConceptual table for WEP default keys. This table shall contain the four WEP default secret key values corresponding to the four possible KeyID values. The WEP…
1.3.6.1.4.1.5624.1.2.9.1.4.2.1RowetsysDot11ExtWEPEnhancedEntrynot-accessiblecurrentAn Entry (conceptual row) in the WEP Default Keys Table. A collection of objects containing information used to determine if a WEPkey as been defined and if so…
1.3.6.1.4.1.5624.1.2.9.1.4.2.1.1ColumnetsysDot11ExtWEPEnhancedImplementedread-onlycurrentThis value indicates whether the AP is capable of Enhanced Wireless Equivalent Privacy (WEP), using 128-bit keys.
1.3.6.1.4.1.5624.1.2.9.1.5NodeetsysDot11ExtEffect
1.3.6.1.4.1.5624.1.2.9.1.5.1TableetsysDot11ExtOIDNotInEffectTablenot-accessiblecurrentThis table will be used to determine which wireless parameters have been modified but are not yet in effect. These parameters will not take effect until a rese…
1.3.6.1.4.1.5624.1.2.9.1.5.1.1RowetsysDot11ExtOIDNotInEffectEntrynot-accessiblecurrent
1.3.6.1.4.1.5624.1.2.9.1.5.1.1.1ColumnetsysDot11ExtOIDIndexnot-accessiblecurrentThis object will keep a list of OIDS
1.3.6.1.4.1.5624.1.2.9.1.5.1.1.2ColumnetsysDot11ExtOIDNotInEffectread-onlycurrentThis object specifies if the OID being accesed currently has been changed but is not in effect.
1.3.6.1.4.1.5624.1.2.9.2NodeetsysDot11ExtConformance
1.3.6.1.4.1.5624.1.2.9.2.1NodeetsysDot11ExtGroups
1.3.6.1.4.1.5624.1.2.9.2.1.1GroupetsysDot11ExtBaseGroupcurrentThe basic etsysDot11Ext stuff.
1.3.6.1.4.1.5624.1.2.9.2.2NodeetsysDot11ExtCompliances
1.3.6.1.4.1.5624.1.2.9.2.2.1ComplianceetsysDot11ExtCompliancecurrentThe compliance statement for devices that support 802Dot11 extensions.