ENVIRONMENT-MIB
35 objects
No module-level DESCRIPTION found.
Imported Objects
| NT-ENTERPRISE-DATA-MIB | ntEnterpriseDataTasmanMgmt |
| SNMPv2-CONF | NOTIFICATION-GROUP |
| SNMPv2-SMI | Gauge32 Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE |
| SNMPv2-TC | TEXTUAL-CONVENTION TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.562.73.1.1.1.3 | IdentitynnenvironmentMib | |||
| 1.3.6.1.4.1.562.73.1.1.1.3.1 | NodennenvObjects | |||
| 1.3.6.1.4.1.562.73.1.1.1.3.1.1 | NodennenvTempSensorGroup | |||
| 1.3.6.1.4.1.562.73.1.1.1.3.1.1.1 | ScalarnnenvTempSensorValue | read-only | current | The Average value of the temperature sensors. |
| 1.3.6.1.4.1.562.73.1.1.1.3.1.1.2 | ScalarnnenvTempSensorState | read-only | current | The Average status of the temperature sensors. |
| 1.3.6.1.4.1.562.73.1.1.1.3.1.2 | TablennenvFanTable | not-accessible | current | A list of fan unit entries. |
| 1.3.6.1.4.1.562.73.1.1.1.3.1.2.1 | RownnenvFanEntry | not-accessible | current | Entry containing information about a fan within the chassis. |
| 1.3.6.1.4.1.562.73.1.1.1.3.1.2.1.1 | ColumnnnenvFanUnitIndex | accessible-for-notify | current | The index to access an entry in the table. |
| 1.3.6.1.4.1.562.73.1.1.1.3.1.2.1.2 | ColumnnnenvFanState | read-only | current | The current state of fan 0, normal/fail. |
| 1.3.6.1.4.1.562.73.1.1.1.3.1.3 | ScalarnnenvPwrsupPowerFailCount | read-only | current | Number of failures of either power supply since boot-up. |
| 1.3.6.1.4.1.562.73.1.1.1.3.1.4 | TablennenvPwrsupTable | not-accessible | current | A list of power supply status information. |
| 1.3.6.1.4.1.562.73.1.1.1.3.1.4.1 | RownnenvPwrsupEntry | not-accessible | current | Entry containing power supply information. |
| 1.3.6.1.4.1.562.73.1.1.1.3.1.4.1.1 | ColumnnnenvPwrsupIndex | accessible-for-notify | current | Index to access entry. |
| 1.3.6.1.4.1.562.73.1.1.1.3.1.4.1.2 | ColumnnnenvPwrsupInstalled | read-only | current | Power supply installed flag. |
| 1.3.6.1.4.1.562.73.1.1.1.3.1.4.1.3 | ColumnnnenvPwrsupStatus | read-only | current | Power supply up/down status. |
| 1.3.6.1.4.1.562.73.1.1.1.3.1.4.1.4 | ColumnnnenvPwrsupType | read-only | current | Power supply type. |
| 1.3.6.1.4.1.562.73.1.1.1.3.1.4.1.5 | ColumnnnenvPwrsupUptime | read-only | current | Seconds since power supply came up. |
| 1.3.6.1.4.1.562.73.1.1.1.3.1.4.1.6 | ColumnnnenvPwrsupDowntime | read-only | current | Seconds since power supply went down. |
| 1.3.6.1.4.1.562.73.1.1.1.3.2 | NodennenvNotificationEnables | |||
| 1.3.6.1.4.1.562.73.1.1.1.3.2.1 | ScalarnnenvEnableTemperatureNotification | read-write | current | Indicates whether the system produces the envTemperatureNotification. The default is yes. Note: implementation is TBD. |
| 1.3.6.1.4.1.562.73.1.1.1.3.2.2 | ScalarnnenvEnableFanNotification | read-write | current | Indicates whether the system produces the envFanNotification. The default is yes. |
| 1.3.6.1.4.1.562.73.1.1.1.3.2.3 | ScalarnnenvEnablePowerNotification | read-write | current | Indicates whether the system produces the envPowerNotification. The default is yes. |
| 1.3.6.1.4.1.562.73.1.1.1.3.3 | NodennenvNotifications | |||
| 1.3.6.1.4.1.562.73.1.1.1.3.3.0 | NodennenvTraps | |||
| 1.3.6.1.4.1.562.73.1.1.1.3.3.0.1 | NotificationnnenvTemperatureNotification | current | An envTemeratureNotification is sent if the environmental monitoring detects that the temperature is at a critical state. This may cause the system to shut dow… | |
| 1.3.6.1.4.1.562.73.1.1.1.3.3.0.2 | NotificationnnenvFanNotification | current | An envFanNotification is sent if the environmental monitoring detects that a fan is in a critical state. This may cause the system to shut down. This notificat… | |
| 1.3.6.1.4.1.562.73.1.1.1.3.3.0.3 | NotificationnnenvPowerSupply1DownNotification | current | An envPowerNotification is sent if the environmental monitoring detects that a power supply has changed status. This notification is sent only if envEnablePowe… | |
| 1.3.6.1.4.1.562.73.1.1.1.3.3.0.4 | NotificationnnenvPowerSupply1UpNotification | current | An envPowerNotification is sent if the environmental monitoring detects that a power supply has changed status. This notification is sent only if envEnablePowe… | |
| 1.3.6.1.4.1.562.73.1.1.1.3.3.0.5 | NotificationnnenvPowerSupply2DownNotification | current | An envPowerNotification is sent if the environmental monitoring detects that a power supply has changed status. This notification is sent only if envEnablePowe… | |
| 1.3.6.1.4.1.562.73.1.1.1.3.3.0.6 | NotificationnnenvPowerSupply2UpNotification | current | An envPowerNotification is sent if the environmental monitoring detects that a power supply has changed status. This notification is sent only if envEnablePowe… | |
| 1.3.6.1.4.1.562.73.1.1.1.3.4 | GroupnnenvironementNotificationGroup | current | THE Envrionment MIB Notification Group |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| EnvInstalled | INTEGER { not-installed(1), installed(2) } | current | Installed flag for power supply. |
| EnvState | INTEGER { normal(1), warning(2), critical(3), fail(4), turned-off(5) } | current | Represents the state of a device being monitored. |
| EnvStatus | INTEGER { absent(1), failed(2), normal(3) } | current | Installed flag for power supply. |
| EnvType | INTEGER { supply-AC-ONLY(1), supply-AC-PoE(2), supply-DC(3), unknown(4) } | current | Installed flag for power supply. |