FEC-SYSPED-MIB
15 objects
The MIB module for PED specific parts.
Imported Objects
| BINTEC-MIB MISSING | Date sys |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | enterprises mib-2 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString TimeStamp TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.272.4.17.6 | IdentitysysPEDMIB | The MIB module for PED specific parts. | ||
| 1.3.6.1.4.1.272.4.17.6.1 | NodesysPedRelay | |||
| 1.3.6.1.4.1.272.4.17.6.1.1 | ScalarsysPedRelay1State | read-write | current | Relay control. open : Relay is open. closed: Relay is closed. Default state is open. |
| 1.3.6.1.4.1.272.4.17.6.1.2 | ScalarsysPedRelay2State | read-write | current | Relay control. open : Relay is open. closed: Relay is closed. Default state is open. |
| 1.3.6.1.4.1.272.4.17.6.1.31 | ScalarsysPedRelayCount | read-only | current | Number of available relays in the system. |
| 1.3.6.1.4.1.272.4.17.6.2 | NodesysPedTemperature | |||
| 1.3.6.1.4.1.272.4.17.6.2.1 | ScalarsysPedTemperatureCurrent | read-only | current | Temperature during the last measurement time. |
| 1.3.6.1.4.1.272.4.17.6.2.2 | ScalarsysPedTemperatureMax | read-only | current | Maximum observed temperature. |
| 1.3.6.1.4.1.272.4.17.6.2.3 | ScalarsysPedTemperatureMaxTime | read-only | current | Point in time the maximum temperature was observed. |
| 1.3.6.1.4.1.272.4.17.6.2.4 | ScalarsysPedTemperatureMin | read-only | current | Minimum observed temperature. |
| 1.3.6.1.4.1.272.4.17.6.2.5 | ScalarsysPedTemperatureMinTime | read-only | current | Point in time the minimum temperature was observed. |
| 1.3.6.1.4.1.272.4.17.6.2.6 | ScalarsysPedTemperatureUpdatePeriod | read-write | current | Measurement interval of temperature update in seconds. 0: Disable measurements. |
| 1.3.6.1.4.1.272.4.17.6.2.7 | ScalarsysPedTemperatureLowerThreshold | read-write | current | Minimal allowed temperature. If temperature falls below this threshold, a syslog message is generated. |
| 1.3.6.1.4.1.272.4.17.6.2.8 | ScalarsysPedTemperatureUpperThreshold | read-write | current | Maximal allowed temperature. If temperature raises above this threshold, a syslog message is generated. |
| 1.3.6.1.4.1.272.4.17.6.2.9 | ScalarsysPedTemperatureAlarm | read-only | current | Indicates if the defined temperature thresholds are violated. |