MIB Viewer

FIBROLAN-ATOMIC-CLOCK-MIB

22 objects
The MIB module to describe Fibrolan's Atomic Clock feature. This module includes the relevant traps as well. This module is part of Fibrolan's group of generic MIB modules (i.e. can be supported on different devices). Copyright (C) Fibrolan Ltd. (2015).
Imported Objects
FIBROLAN-COMMON-MIBfibrolanGeneric
SNMPv2-SMIInteger32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE TimeTicks
SNMPv2-TCDisplayString
OIDNameAccessStatusDescription
1.3.6.1.4.1.4467.1000.220IdentityflAtomicClockThe MIB module to describe Fibrolan's Atomic Clock feature. This module includes the relevant traps as well. This module is part of Fibrolan's group of generic…
1.3.6.1.4.1.4467.1000.220.0NodeflAtomicClockNotifications
1.3.6.1.4.1.4467.1000.220.0.10NotificationflAtomicClockStateChangecurrentIndicates the Atomic Clock has changed state.
1.3.6.1.4.1.4467.1000.220.0.20NotificationflAtomicClockTemperatureAlarmStateChangecurrentIndicates the Atomic Clock temperature alarm state has changed.
1.3.6.1.4.1.4467.1000.220.1NodeflAtomicClockMIBObjects
1.3.6.1.4.1.4467.1000.220.1.10TableflAtomicClockTablenot-accessiblecurrentThis tables provides inventory and status details on the Atomic Clock module and oscillator.
1.3.6.1.4.1.4467.1000.220.1.10.1RowflAtomicClockEntrynot-accessiblecurrentThe entries of the Atomic Clock module table.
1.3.6.1.4.1.4467.1000.220.1.10.1.1ColumnflAtomicClockModuleIdnot-accessiblecurrentThe Atomic Clock module ID (index).
1.3.6.1.4.1.4467.1000.220.1.10.1.2ColumnflAtomicClockModuleTyperead-onlycurrentIndicates the Atomic Clock module type (e.g. RBCM-1).
1.3.6.1.4.1.4467.1000.220.1.10.1.3ColumnflAtomicClockModulePartNumberread-onlycurrentIndicates the Atomic Clock module part number.
1.3.6.1.4.1.4467.1000.220.1.10.1.4ColumnflAtomicClockModuleSerialNumberread-onlycurrentIndicates the Atomic Clock module serial number.
1.3.6.1.4.1.4467.1000.220.1.10.1.5ColumnflAtomicClockOscillatorTyperead-onlycurrentIndicates the Atomic Clock oscillator type.
1.3.6.1.4.1.4467.1000.220.1.10.1.6ColumnflAtomicClockOscillatorPartNumberread-onlycurrentIndicates the Atomic Clock oscillator part number.
1.3.6.1.4.1.4467.1000.220.1.10.1.7ColumnflAtomicClockOscillatorSerialNumberread-onlycurrentIndicates the Atomic Clock oscillator serial number.
1.3.6.1.4.1.4467.1000.220.1.10.1.8ColumnflAtomicClockOscillatorFwVersionread-onlycurrentIndicates the Atomic Clock oscillator FW version.
1.3.6.1.4.1.4467.1000.220.1.10.1.9ColumnflAtomicClockStateread-onlycurrentThe current state of the Atomic Clock module. Under normal conditions, from power up, the state sequence should move from unplugged (may be skipped) to warming…
1.3.6.1.4.1.4467.1000.220.1.10.1.10ColumnflAtomicClockStateLastChangeread-onlycurrentThe value of MIB II's sysUpTime object at the time the module entered its current state.
1.3.6.1.4.1.4467.1000.220.1.10.1.11ColumnflAtomicClockTemperatureread-onlycurrentThe current temperature of the Atomic Clock module/oscillator. Value is in degrees Celsius.
1.3.6.1.4.1.4467.1000.220.1.10.1.12ColumnflAtomicClockTemperatureAlarmStateread-onlycurrentThe current temperature alarm state of the Atomic Clock module/oscillator. Should normally return 'normal'. A value of 'warning' means the module is still func…
1.3.6.1.4.1.4467.1000.220.1.10.1.13ColumnflAtomicClockCellHeaterCurrentread-onlycurrentThe current value of the Cell Heater Current of the Atomic Clock oscillator (when applicable). Value is in [mA].
1.3.6.1.4.1.4467.1000.220.1.10.1.14ColumnflAtomicClockCellHeaterCurrentAlarmStateread-onlycurrentThe current cell heater current alarm state of the Atomic Clock module/oscillator. Should normally return 'normal'. A value of 'warning' means the module is st…
1.3.6.1.4.1.4467.1000.220.1.10.1.15ColumnflAtomicClockAdjustPp15read-onlycurrentThe current digital adjust value of the Atomic Clock (when applicable). This object may be ignored by users and is mostly used for internal monitoring and diag…